Loading...
HomeMy WebLinkAbout141 E Santa Clara St - 2024 -(E) GATE 12" DRYWALL 12" DRYWALL OPEN NON LOAD BEARING WALL SEE PLATE CONNECTION DETAILS SHEET S-1 ALL GENDER RESTROOM PLACARD ON DOORS ALL GENDER RESTROOM PLACARD ON DOORS ACCESSIBLE PLACARD ON DOOR ACCESSIBLE PLACARD ADJACENT TO DOOR 48" AFF WITH RAISED LETTERS AND BRAILLE ADA EGRESS SIGN WITHBRAILLE AND RAISED CHARACTERS 48" TO 60" AFF ADA EXIT SIGN WITHBRAILLE AND RAISED CHARACTERS 48" TO 60" AFF ADA ROOM ID SIGN WITH BRAILLE AND RAISEDCHARACTERS 48" TO 60" AFF ADA ROOM ID SIGN WITH BRAILLE AND RAISED CHARACTERS 48" TO 60" AFF ACCESSIBLE ALL GENDER PLACARD ADJACENT TO DOOR 48" AFF WITH RAISED LETTERS AND BRAILLE SHEET INDEX SHEET #SHEET NAME VERSION DATE REV # T-1 COVER PAGE - SITE PLAN AND NOTES 8/20/2024 2 T-2 GENERAL NOTES 8/20/2024 2 T-3 GENERAL NOTES CONT.8/20/2024 2 A-1 FLOOR PLAN - BEFORE RENOVATIONS 8/20/2024 2 A-2 FLOOR PLAN - AFTER RENOVATIONS 8/20/2024 2 A-3 TITLE 24 ENVELOPE (NEW SHEET)8/20/2024 2 A-4 DETAILS 8/20/2024 2 E-1 ELECTRICAL NOTES AND SINGLE LINE DIAGRAM 6/26/2024 E-2 ELECTRICAL SITE PLAN 6/26/2024 E-3 POWER PLAN 6/26/2024 E-4 LIGHTING PLAN 6/26/2024 E-4.1 ELECTRICAL DETAILS 6/26/2024 E-5 CA ENERGY EFFICIENCY TABLES 6/26/2024 P-1 PLUMBING NOTES AND DETAILS 6/26/2024 P-2 SITE PLAN AND PLUMBING SCHEDULE 6/26/2024 P-3 PLUMBING HOT/COLD WATER, VENT/WATER PLANS 6/26/2024 P-4 PLUMBING ISOMETRIC DIAGRAMS AND DETAILS 6/26/2024 S-1 STRUCTURAL PLANS AND DETAILS 9/3/2024 S-2 STRUCTURAL PLANS AND DETAILS CONT.9/3/2024 T24-1 TITLE 24 7/30/2024 T24-2 TITLE 24 7/30/2024 T24-3 TITLE 24 7/30/2024 T24-4 TITLE 24 7/30/2024 T24-5 TITLE 24 7/30/2024 T24-6 TITLE 24 7/30/2024 SHEET NUMBER SHEET TITLE PROJECT ADDRESS ISSUE FOR STAMP CURRENT REVISION # REVISION HISTORY #REASON DATE 1 CITY CORRECTIONS 7/23/2024 2 CITY CORRECTIONS 8/20/2024 141 E SANTA CLARA STREET ARCADIA, CA 91006 COVER SHEET T-1 PLAN CHECK DRAWN BY HP PRINCIPLE IN CHARGE HP GENERAL NOTES TENANT IMPROVEMENTS 141 E SANTA CLARA STREET ARCADIA, CA 91006 SCOPE OF WORK CODE SUMMARY VICINITY MAP SYMBOLS (IF APPLICABLE) PROJECT DIRECTORY DATE: Apex Properties 9055 LAS TUNAS DRIVE SUITE 200 TEMPLE CITY, CA 91780 8/20/2024 CONSTRUCTION NOTES (E) SITE PLAN SCALE 3/32"=1'-0" TE N A N T IM P R O V E M E N T S 14 1 E S A N T A C L A R A S T R E E T AR C A D I A , C A 9 1 0 0 6 A PROPERTY LINE 11'-9" EXISTING SETBACK 160' P.L. 50' P.L. 49'-10" BUILDING O.D. 113'-112" 21'-3" 35'-112" 28'-7" 148'-3" BUILDING O.D. PROPERTY LINE CL CL 21'-9" 20'-11" 1" EXISTING SETBACK 1" EXISTING SETBACK PROPERTY LINE PROPERTY LINE 2 SHEET NUMBER SHEET TITLE PROJECT ADDRESS ISSUE FOR STAMP CURRENT REVISION # REVISION HISTORY #REASON DATE 1 CITY CORRECTIONS 7/23/2024 2 CITY CORRECTIONS 8/20/2024 141 E SANTA CLARA STREET ARCADIA, CA 91006 GENERAL NOTES T-2 PLAN CHECK DRAWN BY HP PRINCIPLE IN CHARGE HP DATE: Apex Properties 9055 LAS TUNAS DRIVE SUITE 200 TEMPLE CITY, CA 91780 626-590-8918 08/20/2024 TE N A N T IM P R O V E M E N T S 14 1 E S A N T A C L A R A S T R E E T AR C A D I A , C A 9 1 0 0 6 FIBERGLASS, BATT INSULATION BETWEEN STUDS. 6. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE WRAPPED WITH INSULATION. 7. INSULATE ALL 1ST, AND 2ND. FLOOR BATHROOM WASTE PIPES FOR SOUND. 8. EXPOSED HOT WATER PIPING UNDER LAVATORIES SHALL BE WFAPPED WITH INSULATION. H. ROOF NOTES 1. ALL ROOF CONSTRUCTION AND COVERINGS SHALL BE PER CHAPTER 9 & 15 OF THE 2022 CALIFORNIA BUILDING CODE (CBC] . 2. ALL SHEET METAL ROOF WORK SHALL BE PER CHAPTER 15 OF THE 2022 CALIFORNIA BUILDING CODE (CBC). 3. FLASH AND COUNTER FLASH AROUND ROOF PENETRATIONS AS REQUIRED. 4. INSTALL ROOFING MATERIALS IN ACCORDANCE WITH ALL MANUFACTURER'S WRITTEN SPECIFICATIONS AND RECOMMENDATIONS. 5. CONCRETE TILE ROOFING SHALL BE EQUAL TO PER OWNER SPEC WITH APPROVAL FROM GOVERNING MUNICIPALITY UNDERLAYMENT TO BE A MINIMUM OF ONE LAYER 30# FELT IN ACCORDANCE W/ 2022 CBC SECTION 1507,3.10. I. ENERGY CONSERVATION NOTES 1. USE COMPUTER PROGRAM DESIGN ANALYSIS METHOD TO COMPLY WITH ENERGY REQUIREMENT. SEE ENERGY CALCULATIONS. 2. ALL HEATING, VENTILATING, AIR CONDITIONING, AND WATER HEATING EQUIPMENT SHALL MEET ALL REQUIREMENTS OF APPLIANCE EFFICIENCY STANDARDS AND BE CERTIFIED BY CALIFORNIA ENERGY COMMISSION. 3. THERMOSTATS SHALL BE EQUIPPED WITH AUTOMATIC SETBACK, WHICH OCCUPANT CAN PROGRAM TO AUTOMATICALLY SET BACK THE THERMOSTAT TWICE IN 24 HOURS. 4. EQUIPMENT WHICH REQUIRES PREVENTIVE MAINTENANCE TO MAINTAIN EFFICIENT OPERATION SHALL BE FURNISHED WITH COMPLETE NECESSARY MAINTENANCE INFORMATION. 5, ALL FAN SYSTEMS EXHAUSTING AIR TO OUTSIDE SHALL BE PROVIDED WITH AUTOMATIC BACK DRAFT DAMPERS. 6. ALL TRANSVERSE DUCT, PLENUM, AND FITTING JOINTS SHALL BE SEALED WITH PRESSURE SENSITIVE TAPE OR MASTIC TO PREVENT AIR LOSS AND SHALL BE INSULATED. 7. ALL MANUFACTURED WINDOWS AND SLIDING GLASS DOORS SHALL MEET THE ANSI AIR FILTRATION STANDARDS AND SHALL BE CERTIFIED AND LABELED. 8. ALL SWINGING DOORS AND WINDOWS LEADING TO UNCONDITIONED AREAS SHALL BE FULLY WEATHER-STRIPPED. 9. STORAGE TYPE WATER HEATERS SHALL BE EXTERNALLY WRAPPED WITH R-13 INSULATION OR GREATER. 10. THE FIVE FEET OF PIPE CLOSEST TO THE WATER HEATER, IF OUTSIDE CONDITIONED SPACE, SHALL BE INSULATED WITH A MINIMUM OF R-6 STEAM AND STEAM CONDENISATION RETURN PIPING AND RECALCULATING HOT WATER PIPING OUTSIDE THE BUILDING ENVELOPE SHALL 5E INSULATED IN ACCORDANCE WITH T-20-1406. (D) 11. LAMPS USED IN LUMINARIES FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE AN EFFICIENCY OF NOT LESS THAN 40 LUMENS PER WATT. 12. SHOWER HEAD AND FAUCETS SHALL BE EQUIPPED WITH FLOW RESTRICTORS AS OUTLINED IN THE APPLIANCE EFFICIENCY STANDARDS AND SHALL BE CERTIFIED BY THE CALIFORNIA ENERGY COMMISSION, 13. ALL INISULATION USED SHALL COMPLY WITH CALIFORNIA QUALITf STANDARDS. 14. AFTER INSTALLING INSULATION THE INSTALLER SHALL FOST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER AND THE BUILDER STATING THAT THE INSTALLATION CONFORMS TO THE REQUIREMENTS OF TITLE 24, PART 2, CHAPTER 2"33, AND THAT THE MATERIALS INSTALLED CONFORM WITH THE REQUIREMENTS OF TITLE 20,CHAPTER 2, SUBCHAPTER 4, ARTICLE 3. THE CERTIFICATE SHALL STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED ' R" VALUE, AND (IN APPLICATION OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED DENSITY FOR THE DESIRED "R" VALUE. 15. FOR INFILTRATION CONTROL, ALL OPENINGS AND PENETRATIONS MUST BE CAULKED AND SEALED, SUCH AS AROUND WINDOWS, AT SOLE PLATES AND OPENINGS FOR UTILITY PIPES AND WIRES. 16. DUCTWORK MUST COMPLY WITH CHAPTER 6, 2022 CALIFORNIA MECHANICAL CODE (CMC) . 17. FACTORY BUILT FIREPLACES MUST HAVE CLOSABLE METAL OR GLASS DOORS COVERING FIRE BOX OPENINGS. COMBUSTION AIR INTAKE DUCTS ARE REQUIRED (SIX SQUARE INCHES MINIMUM) WITH DAMPERS, FLUE DAMPERS ARE ALSO REQUIRED. ALL FIREPLACES SHALL BE EQUIPPED WITH GLASS DOORS IN COMPLIANCE WITH TITLE 24 ENERGY CONSERVATION REGULATIONS. 18. PERMANENT VACUUM BREAKERS SHALL BE INCLUDED WITH BALL HOSE BIBBS. J. GENERAL PROVISIONS 1. PROVIDE SHEET METAL DRYER VENT TO EXTERIOR. PROVIDE RECESSED SUPPLY AND DRAIN UNIT FOR WASHER. AT SECOND FLOOR LOCATIONS PROVIDE SHEET METAL DRAIN PAN WITH l" DRAIN LINE TO APPROVED RECEPTOR. 2. PROVIDE MAILBOX UNIT EQUAL TO SURFACE MOUNTED U.S.P .S. APPROVED UNIT MODEL WITH NEWSPAPER RECEPTACLE, INDIVIDUAL LOCKABLE COMPARTMENTS. 3. PROVIDE BUILDING ADDRESS AND UNIT NUMBER IDENTIFICATION, STYLE TO BE APPROVED 6Y OWNER. 4. BUILDING ADDRESS MUST BE PROVIDED ON THE FRONT OF THE BUILDING. NUMBERS MUST BE VISIBLE FROM THE STREET, MUST BE OF A COLOR, WHICH CONTRASTS WITH THE BACKGROUND AND MUST BE AT LEAST 4" IN HEIGHT AND 2' IN WIDTH. 2022 CBC SECTION 501 . 5. FIREPLACE TO BE OWNER DESIGNATED WITH APPROVAL FROM PLANNING . PROVIDE GLASS DOORS AND OUTSIDE AIR INTAKES. 6. GAS FIRED WATER HEATER TO BE OWNER DESIGNATED WITH APPROVAL FROM PLANNING . (C.E.C. APPROVED). PROVIDED B-VENT THROUGH ROOF AND PT DISCHARGE LINE TO EXTERIOR. 7. ALL UTILITIES MUST BE PLACED UNDERGROUND, ALL CABLES, WIRES, CONDUIT SYSTEMS AND PIPING OUTSIDE BUILDINGS OR STRUCTURES AND WITHIN THE EXTERIOR PROPERTY LINES SHALL BE INSTALLED UNDERGROUND OTHER THAN RISERS IMMEDIATELY ADJACENT AND ATTACHED TO THE BUILDING. 8. FOR CONCRETE, SPECIAL INSPECTION IS REQUIRED IN ACCORDANCE WITH 2022 CBC SECTION l 704A.4 (EXCEPT WHEN WAIVED PER SAID CBC SECTION). 9. DRIVEWAY GRADES AND FORMS SHALL BE INSPECTED AND APPROVED PRIOR TO PLACING CONCRETE. 1 0. NO WATER SERVICE LATERAL, METER OR FLUSH OUT SHALL BE PERMITTED IN ANY DRIVEWAY. NOR SHALL THEY BE LOCATED LESS THAN 3' FROM THE TOP OF OF ANY DRIVEWAY OR OTHER UTILITY INSTALLATION. 11 . MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO HEATING AND AIR CONDITIONING DEVICES SHALL NOT BE PERMITTED IN ANY REQUIRED FRONT, SIDE OR REAR YEAR. SAID EQUIPMENT SHALL NOT PRODUCE A SOUND LEVEL IN EXCESS OF 55 DB. 12. PROVIDE ADDITIONAL PROTECTIVE BARRIERS ON GARAGE WALLS, SO LOCATED AS TO PROTECT THE WALL FINISHES OF WOODEN FRAME CONSTRUCTION FROM DAMAGE BY AUTOMOBILES. 13. A SMOKE DETECTOR SHALL BE INSTALLED ALL OF THE FOLLOWING LOCATIONS: A) ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS. B) IN EACH ROOM USED FOR SLEEPING PURPOSES. C) IN EACH STORY WITHIN A DWELLING UNIT, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SFLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS. A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. 14. DEFERRED SUBMITTALS (TRUSSES, FABRICATED STAIRS/GUARDRAILS, ETC.) MUST BE REVIEWED, SIGNED, AND STAMPED BY ARCHITECT OR ENGINEER OF RECORD PRIOR SUBMITTAL TO THE BUILDING DIVISION, AND SHALL BE REVIEWED AND APPROVED BY THE CITY PRIOR TO INSTALLATION. CBC 106.3.4.2. K. BATHROOM PROVISION NOTES 1. PROVIDE GFI PROTECTION AT OUTLETS AS REQUIRED. 2. PROVIDE EXHAUST FAN WITH SWITCH AT ALL BATHROOMS WHERE REQUIRED. 3. PROVIDE HIGH EFFICACY LIGHT FIXTURE OVER MIRROR WHERE OCCUR. 4, PROVIDE HEAT LAMP AS REQUIRED, 5. CEMENT, FIBER-CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM Cl 178, C1298 OR C1325 SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS, WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840. REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840. WATER-RESISTANT GYPSUM BOARD SHALL NOT BE USED IN THE FOLLOWING LOCATIONS: (2509.21) A. OVER A VAPOR RETARDER. B. IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY, SUCH AS SAUNAS, STEAM ROOMS OR GANG SHOWER ROOMS. C. ON CEILINGS WHERE FRAME SPACING EXCEEDS 12' O.C. FOR 1/2" THICK AND MORE THAN 16" O.C. FOR 5/8" THICK. 6, COUNTER TOP SHALL BE SIMULATED MARBLE AS MIN. REQUIRED, SPECIFIC TYPE PER PLAN OR BY OWNER. 7. PROVIDE WATER CLOSET SEATS AND RECESSED WATER SUPPLY UNITS. 8. WATER CLOSET SHALL BE "ULTRA LOW FLUSH" TYPE WITH 1.6 GALLON S MAX, PER FLUSH. 9. MEDICINE CABINETS SHALL BE FRAME-LESS. 10. PROVIDE TOILET PAPER HOLDER, RECESS IN CABINET. 11. PROVIDE 30" TOWEL BAR AT EACH BATHROOM. 12. PROVIDE A ROBE HOOK, DOOR STOP TYPE ON BATH DOORS. 13. BATH TUB TRAP SHALL BE RIGID-TYPE CONNECTION. 14. PROVIDE MECHANICAL VENTILATION CAPABLE OF PROVIDING FIVE AIR CHANGES PER HOUR IN BATHROOMS CONTAINING TUBS OR SHOWER, LAUNDRY ROOMS, AND SIMILAR ROOMS IF REQUIRED OPERABLE WINDOWS ARE NOT PROVIDED (DUCTLESS FANS ARE NOT ACCEPTABLE IN ROOM CONTAINING TUBS OR SHOWERS). (1203-3) L. KITCHEN PROVISION NOTES 1. PROVIDE MICROWAVE OVEN AND 220V OUTLET. 2. PROVIDE SPACE FOR 14 TO 18 CUBIC FOOT REFRIGERATOR, TWO (2) DOOR UNIT. 3. RANGE TO BE GAS 36" WITH DROP-IN COUNTER TOP. PROVIDE 220V OUTLET. 4. RANGE HOOD SHALL BE GE STANDARD RANGE HOOD JV332J, W /2-SPEED FAN AND COOKTOP LIGHT, VENT TO OUTSIDE OR EQ, TO BE APPROVED BY OWNER AND CITY BLDG, DEPT. PROVIDE 110v OUTLET. 5. PROVIDE OUTLET FOR DISHWASHER, DISHWASHER TO BE 24" FIVE (5) CYCLE. 6, PROVIDE OUTLET FOR FOOD WASTE ANY CONTRACTOR PRIOR TO INSTALLATION OR PROCUREMENT OF MATERIALS SHALL NOTIFY ARCHITECT OF PROBLEMS IF ANY. FAILURE TO DO SO SHALL MEAN THAT ALL NECESSARY CORRECTIVE MEASURE, DOCUMENTATION, ETC. SHALL BE DONE BY THAT CONTRACTOR AT HIS OWN EXPENSE AND TIME. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE BUILDING LINES AND LEVELS. THE CONTRACTOR SHALL COMPARE CAREFULLY THE LINES AND LEVELS SHOW ON THE DRAWINGS WITH EXISTING LEVELS FOR THE CONSTRUCTION OF THE WORK AND SHALL CALL THE ARCHITECTS ATTENTION TO ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. 6. DIVISION OF INDUSTRIAL SAFETY: CONTRACTOR SHALL OBTAIN PERMITS FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY AS REQUIRED AND SHALL COMPLY WITH ALL REQUIREMENTS OF THE DIVISION. 7. SUBSTITUTION: NO SUBSTITUTION SHALL BE MADE WITHOUT THE OWNER'S APPROVAL. 8. CHANGES: THE OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK: THE CONTRACTOR SUM BEING ADJUSTED ACCORDINGLY. 9. CUTTING AND PATCHING: ALL TRADES SHALL DO THEIR OWN CUTTING, FITTING, PATCHING ETC. TO MAKE THE SEVERAL PARTS COME TOGETHER PROPERLY AND FIT IT TO RECEIVE OR BE RECEIVED BY WORK OF OTHER TRADES. 10. THE CONTRACTOR SHALL WEEKLY CLEAN-UP, REMOVE AND DISPOSE IN A LEGAL MANNER ALL DEBRIS AND WASTE ATTRIBUTED TO THE JOB. 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACEMENT OF REPAIR, WITHOUT DAMAGE, FOR ANY DAMAGE CAUSED BY HIM OR HIS SUB-CONTRACTOR. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REPLACE OR REMEDY ANY FAULTY, IMPROPER OR INFERIOR MATERIALS OR WORKMANSHIP OR ANY DAMAGE TO THEIR WORK RESULTING THERE-FROM, WITHOUT COST TO OWNER, WHICH SHALL APPEAR WITHIN ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK UNDER THIS CONTRACT. 13. THE TERM 'CONTRACTOR' AS USED HEREIN AND ON THE DRAWINGS SHALL ALSO BE APPLICABLE TO EACH SUB-CONTRACTOR AS REQUIREMENTS PERTAIN TO HIS TRADE. 14. CONTRACTOR SHALL SUBMIT COPIES OF MANUFACTURER'S CATALOG SHEETS, BROCHURES, SHEETS, INSTALLED IN THE SAMPLES, INSTALLATION INSTRUCTION, ETC. ON MANUFACTURED PRODUCTS USED OR INSTALLED IN THE PROJECT FOR OWNER'S ACCEPTANCE BEFORE PURCHASE OR DELIVERY TO THE SITE. NON-COMPLIANCE MAY RESULT IN REJECTION AND NON-ACCEPTANCE. 15. MATERIALS AND PRODUCTS SHALL BE DELIVERED TO THE BUILDING SITE IN ORIGINAL PACKAGES. MATERIALS AND PRODUCTS SHALL BE STORED OFF THE GROUND ON WOOD BLOCKING IN AN UPRIGHT POSITION, PROTECTED FROM THE ELEMENTS, IN A MANNER TO PREVENT DAMAGE OR MARRING OF FINISH. 16. ALL BRACING NECESSARY FOR CONSTRUCTION PURPOSES SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 17. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR A PART OF THE WORK, CONTRACTOR SHALL ASSUME THE MOST STRINGENT CONDITION AMONG THE COMMON PRACTICE OF THAT PARTICULAR CONDITION. 18. ALL TRADES SHALL VERIFY EXACT LOCATION OF ALL UTILITIES, PRIOR TO BIDDING, FAILURE TO DO SO SHALL NOT CONSTITUTE GROUNDS FOR EXTRAS. 19. SEE GRADING PLANS FOR SITE FINISH GRADE ELEVATION, DRAINAGE, CONCRETE SIDEWALK SYSTEM, SITE AND STREET IMPROVEMENTS. 20. SEE LANDSCAPE PLAN DESIGN AND LOCATION OF PAVEMENT AREA AND LANDSCAPE AREA AND MATERIALS USED, EXTERIOR STAIRWAY, AND SECURITY FENCING. 21. ALL WORK SHALL CONFORM TO ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. NOTHING SHOWN IN THESE DRAWINGS SHALL BE CONSTRUED AS PERMISSION TO VIOLATE ANY OF THE ABOVE CODES. 22. CONTRACTOR SHALL COMPLY WITH CBC CHAPTER 33, REGARDING PROTECTION OF PEDESTRIANS DURING CONSTRUCTION. F. LIABILITIES THE DESIGN PROFESSIONAL (DP) SHALL CONSULT WITH THE CLIENT REGARDING THE PROBABLE SERVICES REQUIRED TO COMPLY WITH AMERICAN DISABILITIES ACT (ADA) . THE DP IS NOT AN ATTORNEY NOR SHOULD THE DP'S RENDERING AN OPINION OF PROBABLE SERVICES REQUIREMENTS BE CONSIDERED EQUIVALENT TO A LEGAL INTERPRETATION OF ADA. THE DP'S OPINION WILL BE BASED SOLELY ON HIS OR HER OWN EXPERIENCE AND KNOWLEDGE. THIS REQUIRES THE DP TO MAKE A CERTAIN NUMBER OF ASSUMPTIONS AS TO THE TYPES OF DISABILITIES COVERED BY ADA, THE DEGREE OF ACCESS THAT IS "READILY ACHIEVABLE" AND WHAT CONSTITUTES "READILY ACCESSIBLE AND USABLE," GIVEN THE ASSUMPTIONS WHICH MUST BE MADE, THE DP CANNOT AND DOES NOT GUARANTEE THE ACCURACY OF HIS OR HER OPINION AS TO FULL COMPLIANCE AND IN RECOGNITION OF THAT FACT, THE CLIENT WAIVES ANY CLAIM AGAINST THE DP RELATIVE TO THE ADEQUACY OF THE OPINION TO FULLY COMPLY WITH ADA REQUIREMENTS. THE ARCHITECT WHO SIGNS THESE PLANS. SPECIFICATIONS AND INSTRUMENTS OF SERVICE SHALL NOT BE HELD RESPONSIBLE FOR DAMAGES RESULTING FROM CHANGES OR USES NOT AUTHORIZED OR APPROVED BY THE ARCHITECT. THE SIGNING OF THESE DOCUMENTS WILL NOT IMPOSE A LEGAL DUTY OR RESPONSIBILITY TO OBSERVE THE CONSTRUCTION OF THE FIXED WORKS SUBJECT TO THESE DOCUMENTS. G. INSULATION NOTES I . ROOF/ CEILING INSULATION SHALL BE COMPLIED WITH ENERGY CALCULATION, ROCKWOOL OR FIBERGLASS, BATT INSULATION BETWEEN BOTTOM CHORDS OF ROOF TRUSSES OR ROOF JOISTS. 2. ALL EXTERIOR / INTERIOR WALLS SHALL BE COMPLIED WITH ENERGY CALCULATION, ROCKWOOL OR FIBERGLASS, BATT INSULATION BETWEEN STUDS. 3. ALL RAISED WOOD FLOOR STRUCTURE INSULATION SHALL BE COMPLIED WITHENERGY CALCULATION. ROCKWOOL OR FIBERGLASS, BATT INSULATION BETWEEN FLOOR JOIST. 4. ALL PART·/ AND CORRIDOR WALLS SHALL BE INSULATED PER WALL SCHEDULE/LEGEND. 5. ALL PLUMBING WALLS AND WALLS SURROUNDING AND SEPARATING BATHS AND TOILETS FROM OTHER ROOMS SHALL HAVE R13 ROCKWOOL OR GENERAL NOTES A. CODE ALL WORK SHALL CONFORM TO ALL APPLICABLE FEDERAL STATE AND LOCAL CODES AND ORDINANCES. NOTHING SHOWN IN THESE DRAWINGS SHALL BE CONSTRUED AS PERMISSION TO VIOLATE ANY OF THE FOLLOWING: A. CALIFORNIA BUILDING CODE, 2022 EDITION. B. CALIFORNIA TITLE 24 ENERGY REGULATIONS 2022 EDITION. C. CALIFORNIA TITLE 24 TYPE V BUILDINGS CHAPTERS 2-22 2022 EDITION. D. APPLICABLE FEDERAL, STATE, COUNTY AND LOCAL ORDINANCES AND STATUTES. E. REQUIREMENTS OF THE CALIFORNIA DIVISION OF INDUSTRIAL SAFETY, DEPARTMENT OF OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION. (CAL-OSHA) 2022 EDITION. F. 2022 CMC, 2022 CPC, 2022 CEC, 2022 CFC. 2022 CGC. B. PERMITS THE GENERAL BUILDING PERMIT AND PLAN CHECK FEE SHALL BE SECURED AND PAID FOR BY THE OWNER. ALL OTHER PERMITS SHALL BE TAKEN OUT AND PAID FOR BY THE SUB-CONTRACTOR DIRECTLY RESPONSIBLE. CONTRACTOR SHALL OBTAIN PERMITS FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY AS REQUIRED AND SHALL COMPLY WITH ALL REQUIREMENTS OF THE DIVISION. SEPARATE APPLICATION, FLAN CHECK AND PERMITS ARE REQUIRED FOR: A. RETAINING WALLS B. BLOCK WALLS/FENCES C. ELECTRICAL WORK D. MECHANICAL WORK E. PLUMBING WORK F. DEMOLITION G. CONSTRUCTION DOCUMENT C. CONSTRUCTION DOCUMENT THE INTENTION OF THESE DOCUMENTS IS TO INCLUDE ALL LABOR, MATERIALS, SERVICES, EQUIPMENT AND TRANSPORTATION NECESSARY FOR COMPLETE AND PROPER EXECUTION OF THE WORK INDICATED ON THE DRAWING OR REASONABLY INFERRED THERE FROM. THE ARCHITECT WILL IN NO WA( BE RESPONSIBLE FOR HOW THE FIELD WORK IS PERFORMED, SAFETY IN OR ABOUT THE JOBS SITE. METHODS OF PERFORMANCE OR TIMELINESS IN THE PERFORMANCE OF THE WORK. IF DISCREPANCY EXISTS BETWEEN 1/8" SCALE PLAN AND 1/4" SCALE PLAN, THE LARGER SCALE PLAN SHALL GOVERN. NOTIFY ARCHITECT OF SUCH DISCREPANCY BEFORE PROCEEDING WITH THE WORK. DIMENSIONS SHOWN ON PLAN AND DETAILS ARE TO FACE OF STUD (FOS), FACE OF MASONRY (FOM),. FACE OF CONCRETE (FOC), UNLESS OTHERWISE INDICATED. WRITTEN DIMENSION SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. D. BIDS BIDDERS PRIOR TO SUBMITTAL OF BIDS SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH THE ARCHITECT'S PLANS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCY, OMISSION, CLARIFICATION, OR ANY INFORMATION NECESSARY FOR COMPLETION OF THEIR SCOPE OF WORK. ANY ITEM NOT COVERED, SHOWN IN DRAWINGS. QUESTIONED. OR CLARIFIED PRIOR TO BIDDING THAT IS NECESSARY FOR PROPER EXECUTION AND COMPLETION OF ANY SCOPE OF WORK SHALL BE PROVIDED BY THE BIDDING CONTRACTOR AT HIS OWN EXPENSE. TRADES SHALL FURNISH ALL LABOR, EQUIPMENT, MATERIALS AND SERVICES REQUIRED TO PERFORM ALL WORK NECESSARY, INDICATED OR REASONABLY INFERRED OR REQUIRED 6Y ANY CODE WITH JURISDICTION TO COMPLETE THEIR SCOPE OF WORK FOR A COMPLETE AND PROPERLY FINISHED JOB. CONTRACTORS PRIOR TO BIDDING SHALL GUARANTEE THAT ALL OTHER SUB-BIDDERS OR SUB-CONTRACTORS SHALL BE GIVEN COMPLETE FULL SETS OF PLANS TO INSURE THAT THEY HAVE INCLUDED ALL ITEMS NECESSARY TO COMPLETE THEIR WORK. ANY ITEM MISSED BY THESE SUB-CONTRACTORS IN THEIR BIDS SHALL BE ABSORBED BY THE GENERAL CONTRACTOR AT HIS OWN EXPENSE AND IN NO WAY WILL EFFECT ANY ADDITIONAL COST OVER AND ABOVE THE FINAL BID. E. CONTRACTOR 1. PRIOR TO COMMENCING. THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS SHALL REVIEW ALL DRAWINGS AND SPECIFICATIONS AND VERIFY CONDITIONS AT THE SITE. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. ALL CLARIFICATION REQUESTED BY CONTRACTOR FROM THE ARCHITECT BEFORE OR AFTER COMMENCING OF WORK SHALL TAKE OUT LEAST FIVE WORKING DAYS. CONTRACTOR SHALL VERIFY WITH THE PROPER UTILITY COMPANY THE LOCATIONS OF ALL EXISTING BELOW GRADE UTILITIES AND THEIR SERVICE CONNECTIONS PRIOR TO THE COMMENCEMENT OF WORK. 2. NO CONTRACTOR, SUB-CONTRACTOR OR SUB SUB-CONTRACTOR IS TO START WORK UNTIL HE/ SHE HAS FIRST EXAMINED THE EXISTING CONDITIONS. IF FOR ANY REASON A PERFECT JOB IS IMPOSSIBLE, IT SHALL BE IMMEDIATELY REPORTED TO THE PROJECT SUPERINTENDENT AND ARCHITECT BEFORE PROCEEDING WITH THE WORK. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, FOR SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF ASSEMBLY, FOR COORDINATION OF HIS WORK WITH THAT OF OTHER TRADES AND FOR PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER. 4. CONTRACTOR TO VERIFY AND ENSURE AVAILABILITY AND TIMELY DELIVERY OF SPECIFIED OR SUBSTITUTED PRODUCTS PRIOR TO CONSTRUCTION. HE SHALL NOTIFY ARCHITECT OF POSSIBLE CHANGES TO CONSTRUCTION DOCUMENTS OR CONSTRUCTION DELAY DUE TO NON AVAILABILITY OR LATE DELIVERY OF MATERIALS. ARCHITECT IS NOT RESPONSIBLE FOR NON AVAILABILITY OR LATE DELIVERY OF PRODUCTS DURING CONSTRUCTION. 7. PROVIDE GFI OUTLETS WITHIN SIX (6) FEET OF KITCHEN SINK, AND 4 FEET ON-CENTER AT COUNTER AND ISLAND. 8. KITCHEN SINK TO BE DOUBLE COMPARTMENT WHITE ENAMEL UNIT PER PLAN OR SELECT BY OWNER. 9. ALL CABINET TO HAVE STAIN GRADE FINISH OR SELECT BY OWNER. 10. PROVIDE FLUORESCENT FIXTURES UNDER OVERHEAD CABINETS OR SELECT BY OWNER. 11 . COUNTER TOPS TO BE ROLLED LAMINATED PLASTIC WITH INTEGRAL SPLASH AS MIN. REQUIRED. SPECIFIC TYPE PER FLAN OR BY OWNER. M. MISC. CONSTRUCTION NOTES 1 . LATH, PLASTER AND DRYWALL SPECIFICATION SHALL CONFORM TO THE REQUIREMENTS OF 2022 CBC CHAPTER 25. GYPSUM BOARD AND PLASTER SHALL BE NAILED TO ALL STUDS AND TO TOP AND BOTTOM PLATES. 2. INSPECTION OF NAILING REQUIRED FOR DRYWALL AND ALL LATH WHEN IN PLACE IN ACCORDANCE WITH 2022 CBC SECTION 2503. 3. PROVIDE WEEP SCREED BELOW FOUNDATION PLATE LINE & 4" ABOVE GRADE ON ALL EXTERIOR STUD WALLS IN ACCORDANCE W/ 2022 CBC SECTION 2512.1.2. 4. SEPARATE ELECTRICAL PLUMBING AND MECHANICAL EQUIPMENT AND/OR SYSTEMS WILL BE COMPLETELY SEPARATE FOR EACH UNIT. 5. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND, OR OBTAIN NECESSARY PERMIT FORM STATE OF CALIFORNIA, DIVISION OF INDUSTRIAL SAFE PRIOR TO THE ISSUANCE OF A BUILDING OR GRADING PERMIT. 6. PROVIDE SUBDRAINS. 7. RETAINING WALLS SHALL BE WATERPROOF BEFORE BACKFILLING AT BUILDING WHERE OCCURS. 8. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES FORMED WHERE CEILING ARE APPLIED DIRECTLY TO THE UNDER SIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATION OPENING PROTECTED AGAINST THE ENTRANCE OF RAIN SNOW. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN I /300 OF THE AREA OF THE SPACE VENTILATED, MIN. 50% OF THE VENTILATING AREA WILL BE PROVIDED BY EAVES VENT, AND 50% WILL BE PROVIDED B'f DORMER VENT LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3' ABV. EAVES OR CORNICE VENTS. 9. BUILDING PERMIT APPLICATION THAT INVOLVES COMPLETE DEMOLITION OR DEMOLITION OF PART OF THE EXISTING STRUCTURE AND REMOVAL FROM SITE NEEDS WRITTEN APPROVAL FROM THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) (909) 396-2000 PER RULE 1403 FOR THE PROPER DISPOSAL OF ASBESTOS. 10. USE 2-15# FELT BACKING WHEN STUCCO IS APPLIED 0/ PLYWOOD IN ACCORDANCE W / 2022 CBC SECTION 2510.6. 11 . ALL INTERIOR SURFACES OF WALLS AND CEILING SHALL BE COVERED W/PLASTER, MIN. THICK. 7/8" INCHES (22.23MM.) OR GYPSUM WALLBOARD, TYPE X, MIN. THICKNESS 5/8" (15.88 MM.) OR MATERIALS EQUAL IN RIGIDITf AND FIRE RESISTANCE AS APPROVED BY THE BUILDING OFFICIAL. CONCRETE ENCASED ELECTRODE BARE COPPER WIRE SIZED PER 2022 CEC TABLE 250.66 TO REACH THE NEUTRAL LUG OF THE ELECTRICAL SERVICE CONCRETE OR MASONRY STRUCTURE ENOUGH TO REACH THE NEUTRAL 2022 CEC TABLE 250.66 AND LONG BARE COPPER WIRE SIZED PER CONCRETE FOOTING CONCRETE FOOTING LUG OF THE ELECTRICAL SERVICE N. ELECTRICAL NOTES (2022 CEC} 1. THE CENTER OF 15-,20- AND 30-AMPERE RECEPTACLES SHALL BE INSTALLED WITHIN 12 TO 15 INCHES ABOVE THE FLOOR OR WORKING SURFACE PER TITLE 24 AMENDMENT WHERE REQUIRED. 2. IN A CLOSET, SURFACE MOUNTED LIGHT FIXTURES SHALL BE AT LEAST I 8 INCHES FROM A STORAGE AREA AND FLUSH MOUNTED LIGHTING FIXTURES SHALL BE AT LEAST 6 INCHES FROM A STORAGE AREA. ALL SHALL BE PROVIDED W/ PROTECTIVE COVER. 3. GROUND-FAULT CIRCUIT-INTERRUPTER (GFI) PROTECTED ELECTRICAL RECEPTACLES SHALL BE PROVIDED AT ALL RECEPTACLES AS FOLLOWS: A) INSTALLED IN A BATHROOM B) INSTALLED IN A GARAGE AND BASEMENT C) EXTERIOR & CRAWL SPACE D) WITHIN 6FT. OF A KITCHEN SINK AND 4FT. ON CENTER AT COUNTER AND ISLAND. 4. ELECTRICAL RECEPTACLES INSTALLED OUTDOORS WHERE EXPOSED TO WEATHER SHALL BE IN A WEATHERPROOF ENCLOSURE. 5. LOCATION FOR ALL NEW ELECTRICAL SERVICES SHALL BE REQUIRED PER EDISON CO. 6. SMOKE DETECTORS MUST RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING, INTERCONNECTED, AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. 7. ANY FIXED APPLIANCE SUCH AS DISPOSAL, DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATIERS, OR ANY OTHER FIXED APPLIANCE WITH 1 .4 H.P. MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE INSTALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT SUPPLIED WITH MINIMUM #12 AWG WIRE AND A 15 AMP INDICATING-TYPE SWITCH. 8. EACH KITCHEN SHALL BE PR.OVIDED WITH A SEPARATE FOOD WASTE GRINDER BRANCH CIRCUIT. 9. ALUMINUM CONDUCTORS SMALLER THAT NO. 4 A.W.G. REQUIRE CONTINUOUS INSPECTION B'f A SPECIAL INSPECTOR APPROVED BY THE BUILDING OFFICIAL 10. PROVIDE EXHAUST FAN W/ 50 CFM MIN. PER TABLE~ CMC IN BATHROOMS CONTAINING TUBS OR SHOWERS, LAUNDRY ROOMS, AND SIMILAR ROOMS IF REQUIRED OR WHEN OPERABLE WINDOWS ARE NOT PROVIDED. 11. GENERAL LIGHTING IN KITCHENS SHALL HAVE AN EFFICIENCY OF NOT LESS THAN 40 LUMENS PER WATT (FLUORESCENT). 12. RECEPTACLE OUTLETS SHALL BE LOCATED WITHIN 12 TO 15 INCHES OFF THE FLOOR. 13. LIGHT SWITCHES SHALL BE INSTALLED WITHIN 34 TO -48 INCHES OFF THE FLOOR. 2 SHEET NUMBER SHEET TITLE PROJECT ADDRESS ISSUE FOR STAMP CURRENT REVISION # REVISION HISTORY #REASON DATE 1 CITY CORRECTIONS 7/23/2024 2 CITY CORRECTIONS 8/20/2024 141 E SANTA CLARA STREET ARCADIA, CA 91006 GENERAL NOTES CONT. T-3 PLAN CHECK DRAWN BY HP PRINCIPLE IN CHARGE HP DATE: Apex Properties 9055 LAS TUNAS DRIVE SUITE 200 TEMPLE CITY, CA 91780 626-590-8918 08/20/2024 TE N A N T IM P R O V E M E N T S 14 1 E S A N T A C L A R A S T R E E T AR C A D I A , C A 9 1 0 0 6 1-4. THERE SHALL BE A DISTRIBUTION PANEL IN. AND FOR EACH UNIT. FEEDERS FOR SUB-PANELS SHALL BE ENCLOSED IN AN APPROVED RACEWAY. 15. THERE SHALL BE NO MORE THAN SIX DISCONNECTING MEANS PER SERVICE, GROUPED IN ANY ONE LOCATION WITHOUT A MAIN DISCONNECT. 16. GROUNDING ELECTRODE ENCASED BY A MINIMUM 2" OF CONCRETE AND LOCATED NEAR THE BOTTOM OF THE FOOTING AT GRADE. THE ELECTRODE SHALL BE BARE COPPER SIZED IN ACCORDANCE WITH 2022 CEC TABLE 250.66 AND ARTICLES 250.50 - 250.70. 17. RECEPTACLE OUTLETS SHALL BE LOCATED WITHIN 15 TO 48 INCHES OF THE FLOOR. 18. NO POINT ALONG THE WALL IS FURTHER THAN 6 FEET FROM A RECEPTACLE. 19. PROVIDE A MIN. OF IOOAMP. ELEC. SERVICE PANEL WITH 1/2" DIA. X 20' LONG REBAR FOR BACKUP UNDER GROUND BONDED TO COLD WATER PIPE. PLEASE CONTACT EDISON FOR METER LOCATION AND UNDERGROUND SERVICE IF REQUIRED. 20. PROVIDE OUTDOOR RECEPTACLE OUTLET WITH WEATHERPROOF COVER AND GROUND FAULT CIRCUIT INTERRUPTER IGFI) AT FRONT AND REAR OF DWELLING UNIT. 21. HEATING AND COOLING EQUIPMENT SHALL BE PROVIDED AN ELECTRICAL RECEPTACLE AND SWITCH CONTROLLED LIGHTING FIXTURE. THE RECEPTACLE SHALL BE INSTALLED WITHIN 25'-0' OF HEATING, AND COOLING EQUIPMENT. THE LIGHTING FIXTURE SHALL BE CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY LEADING TO THE HEATING OR COOLING EQUIPMENT AND SHALL BE PROVIDED AT THE POINT OF ENTRY TO THE ATTIC OR UNDER FLOOR SPACE HOUSING SUCH EQUIPMENT. 2022 CEC ARTICLES 211}-63 AND 21 l}-70(C). 22. COMPLY WITH 2022 CEC SEC. 311.8 REGARDING ELECTRICAL APPURTENANCES (I.E. ELECTRICAL PANELS, OUTLETS, MOTORS, ETC.), 18" MIN. ABOVE FINISH FLOOR. 23. NEW RECEPTACLE OUTLET LOCATIONS WILL COMPLY WITH CEC ARTICLE 210.52 AND CEC 210.52(A) 24. PER CEC ARTICLE 210.11(C)1 A MIN OF 2 SMALL APPLIANCE BRANCH CIRCUITS WITHIN THE LOCATIONS SPECIFIED IN ARTICLE 210.52(B) AND 210.11(C)3 O. MECHANICAL NOTES (2022 CMC) CENTRAL WARM-AIR FURNACES INSTALLED IN ATTIC MUST BE ACCESSIBLE FOR ROUTINE INSPECTION AND MAINTENANCE BY THE OWNER/OCCUPANT AND FOR SERVICE AND REPAIR AS NEEDED. CHANGING FILTERS, LUBRICATING MOTOR AND FAN BEARINGS, CHECKING BELT TENSION, AND RELIGHTING THE PILOT FOLLOWING A SERVICE INTERRUPTION ARE NORMAL OWNER FUNCTIONS. ADEQUATE LIGHIT, AN ELECTRICAL OUTLET, SAFE ACCESS WAY AND SUFFICIENT WORKING SPACE ON THE CONTROL SIDE ALL ENCOURAGE AND FACILITATE MAINTENANCE AND Al.SO ENABLE RAPID EGRESS IN AN EMERGENCY. 1. ATTIC FURNACE SHALL HAVE A. DOUBLE JOIST SUPPORTING UNIT B. LEVEL PLATFORM C. SEISMIC SWAY BRACE OR ANCHOR UNIT TO PLATFORM D. 30" MIN. ACCESS !SEE PLAN) E. CONDENSE DRAIN TO APPROVED PLUMBING FIXTURE F. LIGHT. SWITCH, OUTLET 2. MECHANICAL EQUIPMENTS: HEATING: SEE MECH. DWGS. IF APPLICABLE COOLING: SEE MECH. DWGS. IF APPLICABLE 3. PROVIDE A MINIMUM 30X30 INCH ACCESS; MAXIMUM OF 20 FEET FROM OPENING TO FURNACE, 24 INCH WIDE WALKWAY AND 30 INCH DEEP WORK PLATFORM; PROVIDE ELECTRIC LIGHT OUTLET ADJACENT TO FURNACE AND SWITCH BY THE OPENING. 4. HEATING EQUIPMENT THAT MAY GENERATE A GLOW, SPARK OR FLAME SHALL HAVE BURNERS OR PILOTS 18" ABOVE THE GARAGE FLOOR. 2022 CMC 308.l. 5. DUCTS THROUGH ATTACHED GARAGE INTO DWELLING SHALL BE MINIMUM 26-GAUGE GALVANIZED STEEL. 6. EVERY DWELLING SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF 68 DEGREES FAHRENHEIT AT A POINT 3' ABOVE THE FLOOR IN HABITABLE ROOMS. 2022 CBC SEC. 1204.1. P. PLUMBING NOTES (2022 CPC) l . COMBUSTION AIR FOR WATER HEATERS SHALL BE SUPPLIED PER 507.3; 507.4; 507.4.1 OF 2022 CPC. 2. ANCHOR OR STRAP WATER HEATER AT POINTS WITHIN THE UPPER ONE-THIRD (1/3) AND LOWER ONE-THIRD (1 /3) OF ITS VERTICAL DIMENSIONS. THE LOWER STRAP MUST BE NO CLOSER THAN -4" ABOVE THE CONTROLS. 2022 CPC SEC. 508.2. 3. FIBERGLASS TUB/SHOWER SHALL BE ICBO OR IAPMO APPROVED. 4. BACKWATER VALVE REQUIRED WHEN DRAINAGE PIPING HAS THE FLOOD LEVEL RIM LOCATED BELOW THE ELEVATION OF THE NEXT UPSTREAM MANHOLE COVERS. ALL FIXTURES ABOVE UPSTREAM MANHOLE COVER SHALL NOT DISCHARGE THROUGH THE BACKWATER VALVE. (CPC710. l ) 5. PROVIDE A MIN. OF 3" DIAMETER SEWER/DRAIN LINE WITH 2% MIN. SLOPE. 6. USE 2X6 MIN. STUDS FOR PLUMBING WALLS. 7. SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH MIXING VALVES THAT ARE THE PRESSURE BALANCE TYPE OR TEMPERATURE LIMITING TYPE. 2022 CPC 418.0. 8. FIXTURES HAVING SUP-JOINT CONNECTIONS SHALL HAVE A 12" X 12" MINIMUM ACCESS PANEL. 2022 UPC 404.2. 9. SPECIFY LOW FLOW TOILETS (1.6 GALLON/FLUSH), SHOWERHEADS (2.5 GPM) AND FAUCETS (2.5 GPM). (CPC 402) 10. HOSE BIBBS SHALL BE FITTED WITH A NON-REMOVABLE BACKFLOW PREVENTION DEVICE. ICPC 603.4.7.) 11 . PAD SUPPORTING COMPRESSOR/CONDENSER/WATER HEATER SHALL BE A MINIMUM OF 3" ABOVE GRADE. CMC 30-4.8, CPC 510.6. Q. SITE RELATED GENERAL NOTES l. ALL INDICATED BOUNDARY AND EXISTING SITE CONDITIONS IS BASED ON A SURVEY PREPARED BY THE CIVIL ENGINEER. 2. ALL UTILITY SERVICES SHALL BE INSTALLED UNDERGROUND. 3. FOR SITE PLANTING FEATURES AND IRRIGATION FACILITIES, SEE LANDSCAPE PLANS. 4. FOR SITE GRADING UTILITIES, ELEVATION AND DRAINAGE. SEE CIVIL PLANS. 5. BEFORE COMMENCEMENT OF WORK, CONTRACTOR TO CONTACT ALL GOVERNMENT AGENCIES AND UTILITY COMPANIES WHICH MAY HAVE SERVICES IN THE AREA. THE CONTRACTOR SHALL BE ASSURES THAT ALL UNDERGROUND SERVICES ARE IDENTIFIED PRIOR TO ANY SUBSURFACE EXCAVATION AND SHALL PROTECT ALL EXISTING UNDERGROUND SERVICES. 6. PRIOR TO CONSTRUCTION, CONTRACTOR TO COORDINATE WITH UTILITY COMPANIES AND AGENCIES ON WORK PERTAINING TO SERVICES SUCH AS CABLE TV, ELECTRICITY, GAS, WATER AND SEWER FROM SOURCE OF SERVICES TO BUILDING HOOK-UP. 7. OWNER SHALL FURNISH SERVICES OF GEO-TECHNICAL ENGINEERS TO INCLUDE BUT NOT LIMITED TO SOILS BORING TEST. SOILS BEARING VALUE DETERMINATION, PERCOLATION TEST, EVALUATIONS OF HAZARDOUS MATERIALS, GROUND CORROSION AND RESISTIVITY TESTS INCLUDING NECESSARY OPERATIONS FOR ANTICIPATING SUBSOIL CONDITIONS WITH REPORTS AND RECOMMENDATIONS. 8. SEE SOILS REPORT PREPARED BY CIVIL ENGINEER OF RECORD FOR SITE PREPARATION AND GRADING RECOMMENDATIONS. 9. ALL SURFACE WATER TO DRAIN AWAY FROM BUILDING AND DRIVEWAY TO ALLEY OR STREET OR PUBLIC STORM DRAIN SYSTEM. R. FIRE DEPARTMENT NOTES (2022 CFC) 1. FIRE DEPARTMENT ACCESS ROADS AND PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AND MAINTAINED DURING CONSTRUCTION, ALTERATION OR DEMOLITION OFA BUILDING (CFC SEC l -410 & 1415). 2. A PERMANENT, VISIBLE ADDRESS SIGN (NUMBERS) SHALL BE PERMANENTLY MOUNTED ON THE FRONT FACADE OF THE BUILDING, AS WELL AS INSTALLED TO IDENTIFY EACH UNIT. NUMBERS SHALL BE A MINIMUM 4" HEIGHT WITH 1/2" STROKE, AND SHALL CONTRAST WITH THE BUILDING OR DOOR ON WHICH THEY ARE AFFIXED !CFC SEC 505. l ). 3. APPROVAL OF THIS ARCHITECTURE SET OF DRAWINGS DOES NOT CONSTITUTE OR INCLUDE APPROVAL FOR DEFERRED SUBMITTALS INCLUDING, BUT NOT LIMITED TO, FIRE SPRINKLER AND FIRE ALARM PLANS. ALL FIRE PROTECTION SYSTEMS AND COMPONENTS REQUIRE SEPARATE PLAN SUBMITTAL, APPROVAL AND PERMIT FROM THE FIRE DEPARTMENT. 4. AN AUTOMATIC FIRE SPRINKLER SYSTEM, CONFORMING TO THE NFPA 13 STANDARD, IS REQUIRED FOR THIS PROJECT. FIVE COMPLETE SETS OF PLANS, SPECIFICATIONS AND HYDRAULIC CALCULATIONS SHALL BE SUBMITTED TO THE FIRE DEPARTMENT BY A LICENSED C-16 FIRE PROTECTION CONTRACTOR, FOR SEPARATE REVIEW. APPROVAL AND PERMIT (CFC SEC 903.2.8). 5. APPROVED AUDIBLE ALARM DEVICES SHALL BE CONNECTED TO EVERY AUTOMATIC SPRINKLER SYSTEM. SUCH SPRINKLER WATER-FLOW ALARM DEVICES SHALL BE ACTIVATED BY WATER FLOW EQUIVALENT TO THE FLOW OF A SINGLE SPRINKLER OF THE SMALLEST ORIFICE SIZE INSTALLED IN THE SYSTEM. ALARM DEVICES SHALL BE PROVIDED ON THE EXTERIOR OF THE BUILDING IN AN APPROVED LOCATION. WHERE A FIRE ALARM SYSTEM IS INSTALLED, ACTUATION OF THE AUTOMATIC FIRE SPRINKLER SYSTEM SHALL ACTUATE THE BUILDING FIRE ALARM SYSTEM. APPROVED AUDIBLE NOTIFICATION APPLIANCES SHALL BE PROVIDED IN TIHE INTERIOR OF THE BUILDING AT LOCATIONS REQUIRED BY THE FIRE CHIEF. (AMC 8130.10) 6. HVAC SYSTEMS WITH A CAPACITY OF 2000 CFM OR GREATER SHALL BE EQUIPPED WITH SMOKE DETECTORS INSIDE THE DUCT, AND SUCH DETECTORS SHALL BE TIED INTO THE BUILDING FIRE ALARM SYSTEM, IF APPLICABLE (2016 CMC SEC 609.0). 7. A KNOX KEY BOX IF ANY SHALL BE PERMANENTLY MOUNTED IN AN APPROVED LOCATION ON THE EXTERIOR OF THE BUILDING FOR FIRE DEPARTMENT USE IN AN EMERGENCY. (CFC SEC 506.1). FLOOR PLAN NOTES GENERAL l. THE GOVERNMENT CODES ARE THE 2022 CBC. 2022 CMC. 2022 CFC, 2022 CEC, AND WITH STATE OF CALIFORNIA AND CITY AMENDMENTS. 2. FIELD INSPECTORS TO REVIEW AND APPROVE FUTURE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT. 3. INSPECTION OF NAILING REQUIRED FOR DRYWALL AND ALL LATH WHEN IN PLACE. CORNER BEADS ARE TO BE NAILED. DRYWALL BOARD SPACING TO BE 3/8 INCHES MAXIMUM. 4. GENERAL CONTRACTOR TO VERIFY WITH UTILITY PROVIDERS ALL CONNECTION/METER LOCATIONS PRIOR TO INSTALLATION. (A) MATERIAL/CONSTRUCTION I. EXTERIOR LATH: TWO LAYERS OF GRADE D PAPER SHALL BE APPLIED OVER ALL WOOD BASE SHEATHING. (CBC 2506.4) 2. ALL EXPOSED WOOD AND VENTS TO BE PAINTED. 3. PROVIDE PROTECTION FROM AUTO IMPACT FOR CONCRETE COLUMNS AND METAL DUCT WORKS. 4. EQUIPMENT WHICH HAS A FLAME, GENERA TIES A SPARK OR USES A GLOWING IGNITION SOURCE OPEN TO THE SPACE IN WHICH IT IS INSTALLED SHALL BE ELEVATED SUCH THAT THE SOURCE OF IGNITION IS AT LEAST 18 INCHES ABOVE THE FLOOR IN U-1 OCCUPANCY. 5. A DOOR MAY SWING OVER LANDING THAT IS NOT MORE THAN 1" BELOW THRESHOLD. (CBC 1004.6) THE LANDING, 36 INCHES IN WIDTH, WILL BE PROVIDED ON EACH SIDE OF DOORS. SLOPE OF ANY LANDING SHALL NOT EXCEED l1/4" PER FOOT. 6. ESCAPE OR RESCUE WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENABLE AREA OF 5.7 SQUARE FEET. THE MINIMUM NET CLEAR OPENABLE HEIGHT DIMENSION SHALL BE 24 INCHES. THE MINIMUM NET CLEAR OPENABLE WIDTH DIMENSION SHALL BE 20 INCHES. WHEN WINDOWS ARE PROVIDED AS A MEANS OF ESCAPE OR RESCUE, THEY SHALL HAVE A FINISHED SILL HEIGHT NOT MORE THAN 4-4 INCHES ABOVE THE FLOOR. 7. PROVIDE MIN. 72 INCHES HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER RESISTANT MATERIALS FOR SHOWER ENCLOSURE AND WINDOWS IF SILL IS LESS THAN 5' ABOVE TUB OR SHOWER FLOOR. 8. GLASS ENCLOSURE DOOR(S) AND PANELISJ MUST BE LABELED CATEGORY II. SWING DOOR OUTWARD. NET AREA OF SHOWER RECEPTOR SHALL BE NOT LESS THAN l,024 SQ. IN. OF FLOOR AREA, AND ENCOMPASS 30 INCH DIAMETER CIRCLE. 9. STAIRWAYS AND STEPS NOTES: A. MINIMUM 36" WIDE STAIRWAY AND LANDINGS B. MAXIMUM 7 3/4" RISE, MINIMUM l 0" RUN C. THE LARGEST RISE OR RUN IN A FLIGHT OF STAIRS MAY NOT EXCEED THE SMALLEST BY MORE THAN 3/8" D. STAIRS TO BE 6'-8" MINIMUM HEADROOM FROM NOSING OF TREAD E. GUARDRAIL ON OPEN SIDE OF STAIRS OVER 30 IN. ABOVE FLOOR OR ADJACENT GRADE MAY SERVE AS HANDRAIL ALSO GUARDRAIL MAY BE 34" TO 38" HIGH ONLY AT OPEN SIDE OF STAIRS. F. HANDRAIL (REQUIRED FOR 4 OR MORE RISERS) 34" TO 38" ABOVE TREAD NOSING, 1-1/2" CLEARANCE TO WALL l-1/2'' TO 2" IN CROSS SECTION, WITH ENDS RETURNED TO WALL OR TERMINATED AT NEWEL OR SAFETY POST. G. HANDRAIL CONNECTION DETAILS ADEQUATE TO WITHSTAND A 21}-LBS PER FOOT LATERAL LOAD. (P)PLUMBING (Q) 1. NO GAS PIPING SHALL BE INSTALLED IN OR ON THE GROUND, UNDER ANY BUILDING OR STRUCTURE. ALL EXPOSED GAS PIPING SHALL BE KEPT AT LEAST SIX(6) INCHES ABOVE GRADE OR STRUCTURE. 2. AN APPROVED BACKWATER VALVE IS REQUIRED FOR DRAINAGE PIPING SERVING FIXTURES LOCATED BELOW THE ELEVATION OF THE NEXT UPSTREAM MANHOLE COVER. FIXTURES ABOVE SUCH ELEVATION SHALL NOT DISCHARGE THROUGH THE BACKWATER VALVE. 3. ALL PLUMBING MATERIAL USED IN THE WATER SUPPLY SYSTEM, EXCEPT VALVES AND SIMILAR DEVICES SHALL BE OF LIKE MATERIALS. (UPC-1004(a) I 4. HOSE BIBBS REQUIRE BACK FLOW PREVENTERS. 5. NEW WATER CLOSETS AND ASSOCIATED FLUSHOMETER VALVES, IF ANY, SHALL USE NO MORE THAN 1.6 GALLONS PER FLUSH AND SHALL MEET PERFORMANCE STANDARD ESTABLISHED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE STANDARD Al 12.19.2. H & S CODE, SECTION l 792l.3(B). 6. ALL SHOWERS AND TUB-SHOWER SHALL HAVE EITHER A PRESSURE BALANCE OR A THERMOSTATIC MIXING VALVE. (P.C. 9091) 7. PROVIDE ANTI-SCALDING VALVE IN SHOWERS AND TUB & SHOWERS. 8. WATER HEATER: A. PROVIDE COMBUSTIBLE AIR TO THE WATER HEATER PER U.P.C. 507.3. ONE OPENING AT THE TOP AND ONE OPENING AT THE BOTTOM. EACH OPENING MUST HAVE A MINIMUM OF 100 SQUARE INCHES. B. THE WATER HEATER SHALL BE PROVIDED WITH A CORROSION RESISTANT WATERTIGHT PAN TO PROTECT FROM LEAKING. THE PAN MUST BE PROVIDED WITH A MINIMUM 3/4" DIAMETER DRAIN TO AN APPROVED LOCATION. U.P.C. 510.7 C. TYPE B WATER HEATER SHALL TERMINATED AT LEAST 12" ABOVE THE HIGHEST POINT WHERE THEY PASS THROUGH THE ROOF(if the roof is 6/12 or less) . TYPE L VENTS SHALL TERMINATED AT LEAST 2-4 INCHES ABOVE THE ROOF THROUGH WHICH IT PASSES. U.P.C. 517.3. 517.-4 AND U.P.C. TABLE 5-2. D. THE WATER HEATER SHALL BE PROVIDED WITH A PRESSURE-TEMPERATURE-RELIEF VALVE PER U.P.C. 608.5, 505.3 AND 506.2. PIPE CONNECT TO WATER HEATER TEMPERATURE AND PRESSURE VALVE AND EXTEND TO OUTSIDE OF EXTERIOR WALL, WITH NON END DOWNWARD ABOVE FINISH GRADE WITHIN 6" TO 12'' E. ALL NEW, REPLACEMENT AND EXISTING WATER HEATERS SHALL BE STRAPPED TO THE WALL IN TWO PLACES. ONE IN THE UPPER l /3 OF THE TANK AND ONE IN THE LOWER 1/3 OF THE TANK. THE LOWER POINT SHALL BE A MINIMUM OF-4-INCH ABOVE THE CONTROLS. 9. ALL PLUMBING FIXTURES SHALL BE COMPLIED WITH NEW ENERGY STANDARDS. PROVIDE MAKE AND MODEL NUMBERS OF ALL PLUMBING FIXTURES BEING USED. 10. A 12"Xl2"(MIN.) PLUMBING ACCESS FOR TUBS. (CPC 1210.2) (M)MECHANICAL 1. ALL HEATING SYSTEMS SHALL HAVE AN AUTOMATIC THERMOSTAT WITH A CLOCK MECHANISM WHICH THE BUILDING OCCUPANT CAN MANUALLY PROGRAM TO AUTOMATICALLY SET BACK THE THERMOSTAT SET POINTS AT LEAST 2 PERIODS WITHIN 24 HOURS. 9ENS 150(1) (E) ELECTRICAL 1. ELECTRICAL POWER (I.E. EDISON) COMPANY APPROVAL IS REQUIRED FOR METER LOCATIONS PRIOR TO INSTALLATION. 2. PROVIDE A MINIMUM l 00 AMP ELECTRICAL SERVICE PANEL. 3. PROVIDE A MAIN BREAKER IN ALL SUB-PANELS. 4. ALL 120-VOLT, SINGLE PHASE, 15- AND 21- AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. - 2022 CEC SECTION 21 0. l 2(A) 5. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED IN ALL AREAS SPECIFIED IN 210.52, ALL NONLOCKING-TYPE 12-VOLT; 15- AND 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES. (EC 406.12) 6. RECEPTACLE OUTLETS SHALL BE SPACED AT 12' O.C. MAXIMUM AND SHALL BE LOCATED WITHIN 6' OF DOOR OPENINGS (I.E. CLOSET DOORS, ETC) . ALSO, EVERY 2' OR WIDER OF WALLS. OUTLETS Al.SO REQUIRED FOR COUNTER TOPS AT 4' O.C. AND WITHIN 2 FEET OF ENDS OR BREAKS OR COUNTERS, NEC. 7. ELECTRICAL OUTLETS IN THE FIRE-RESISTIVE WALL BETWEEN THE GARAGE AND DWELLING MUST BE SEPARATED BY A HORIZONTAL DISTANCE OF AT LEASE 24 INCHES. U.B.C. 709.7, EXCEPTION 1 8. BATHROOM RECEPTACLES SHALL BE SERVED BY DEDICATED 20 AMP CIRCUITS - NEC SECTION 210 - 52(d) 9. ANY FIXED APPLIANCE SUCH AS DISPOSAL, DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATERS, OR ANY OTHER FIXED APPLIANCE WITH 1/4 H.P. MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE INSTALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT SUPPLIED WITH MINIMUM #12 AWG WIRE AND A 15 AMP INDICATING-TYPE SWITCH. (CEC210.23 & 220) A. TWO 20 AMP CIRCUITS ARE REQUIRED FOR KITCHEN APPLIANCES. B. EACH FIXED APPLIANCE TO BE ON ONE CIRCUIT. C. TWO SEPARATE 20 AMP CIRCUITS ARE REQUIRED FOR WASHER AND DRYER. 9. SMOKE DETECTORS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE UNIT IN WHICH THEY ARE LOCATED. CBC SECTION 310.9. l .4 10. RESIDENTIAL LIGHTING A. HIGH EFFICACY LUMINARES FOR RESIDENTIAL LIGHTING SHALL CONTAIN ONLY HIGH EFFICACY LAMPS AND SHALL NOT CONTAIN A MEDIUM SCREW BASESOCKET[E25/E26). B. PERMANENTLY INSTALLED LUMINAIRES IN KITCHEN SHALL BE HIGH EFFICACY LUMINAIRES. EXCEPTION: UP TO 50% OF THE TOTAL RATED WATTAGE OF PERMANENTLY INSTALLED LUMINAIRES IN KITCHENS MAY BE IN LUMINAIRES THAT ARE NOT HIGH EFFICACY LUMINAIRES, PROVIDE THAT THESE LUMINAIRES ARE CONTROLLED BY SWITCHES SEPARATE FROM THOSE CONTROLLING THE HIGH EFFICACY LUMINAIRES. THE WATTAGE OF THE HIGH EFFICACY LUMINAIRES SHALL BE BE THE TOTAL NOMINAL RATED WATTAGE ON THE INSTALLED HIGH EFFICACY LAMP(S). THE WATTAGE OF LUMINAIRES SHALL BE DETERMINED AS SPECIFIED BY SEC. 130 (C). C. PERMANENTLY INSTALLED LUMINAIRES IN BATHROOM, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINAIRES. EXCEPTION: PERMANENTLY INSTALLED LUMINAIRES ARE NOT HIGH EFFICACY SHALL BE ALLOWED PROVIDE THAT THEY ARE CONTROLLED BY AN OCCUPANT SENSOR(S) CERTIFIED TO COMPLY WITH SECTION l 19(d). SUCH MOTION SENSORS SHALL NOT HAVE A CONTROL THAT ALLOWS THE LUMINAIRES TO BE TURNED ON AUTOMATICALLY OR THAT HAS AN OVERRIDE ALLOWING THE LUMINAIRES TO BE ALWAYS ON. D. PERMANENTLY INSTALLED LUMINAIRES LOCATED OTHER THAN IN KITCHENS, BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINAIRES. EXCEPTION: (l). PERMANENTLY INSTALLED LUMINAIRES ARE NOT HIGH EFFICACY SHALL BE ALLOWED PROVIDED THEY ARE CONTROLLED BY A DIMMER SWITCH. (2). PERMANENTLY INSTALLED LUMINAIRES ARE NOT HIGH EFFICACY SHALL BE ALLOWED PROVIDED THEY ARE CONTROLLED BY AN OCCUPANT SENSOR[S) CERTIFIED TO COMPLY WITH SECTION 1191d). SUCH MOTION SENSORS SHALL NOT HAVE A CONTROL THAT ALLOWS THE LUMINAIRES TO BE TURNED ON AUTOMATICALLY OR THAT HAS AN OVERRIDE ALLOWING THE LUMINAIRES TO BE ALWAYS ON. (3). PERMANENTLY INSTALLED LUMINAIRES ARE NOT HIGH EFFICACY SHALL BE ALLOWED IN CLOSETS LESS THAN 70 SQUARE FEET. NOTE: LIGHTING IN AREAS ADJACENT TO THE KITCHEN, INCLUDING BUT NOT LIMITED TO DINING AND NOOK AREAS, ARE CONSIDERED KITCHEN LIGHTING IF THEY ARE NOT SEPARATELY SWITCHED FROM KITCHEN LIGHTING. E. LUMINAIRES RECESSED INTO INSULATED CEILINGS SHALL BE APPROVED FOR ZERO CLEARANCE INSULATION COVER(IC) BY UNDERWRITERS LABORATORIES OR OTHER TESTING/RATING LABORATORIES RECOGNIZED BY THE INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS, AND SHALL INCLUDE A LABEL CERTIFYING AIR TIGHT[AT) OR SIMILAR DESIGNATION TO SHOW AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS (OR 1.57 LBS/SF) WHEN TESTED IN ACCORDANCE WITH ASTM E283, AND SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE HOUSING AND CEILING. F. LUMINAIRES PROVIDING OUTDOOR LIGHTING AND PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES. EXCEPTION: (l). PERMANENTLY INSTALLED LUMINAIRES ARE NOT HIGH EFFICACY SHALL BE ALLOWED PROVIDED THEY ARE CONTROLLED BY A MOTION SENSORIS) WITH INTEGRAL PHOTOCONTROL CERTIFIED TO COMPLY WITH SECTION ll9(d). (2). PERMANENTLY INSTALLED LUMINAIRES IN OR AROUND SWIMMING POOLS, WATER FEATURES, OR OTHER LOCATIONS SUBJECT TO ARTICLE 680 OF THE CALIFORNIA ELECTRIC CODE NEED NOT BE HIGH EFFICACY LUMINAIRES. G. LIGHTING FOR PARKING LOTS FOR EIGHT OR MORE VEHICLES SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS IN SECTION 130, 132, AND 147 OF CALIFORNIA ENERGY CODE. LIGHTING FOR PARKING GARAGES FOR EIGHT OR MORE VEHICLES SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS IN SECTION 130, 13 l, AND 146 OF CALIFORNIA ENERGY CODE. H. PERMANENTLY INSTALLED LIGHTING IN THE ENCLOSED, NONDWELLJNG SPACES OF LOW-RISE RESIDENTIAL BUILDINGS WITH FOUR OR MORE DWELLING UNITS SHALL BE HIGH EFFICACY LUMINAIRES. EXCEPTION: (1 ). PERMANENTLY INSTALLED LUMINAIRES THAT ARE NOT HIGH EFFICACY SHALL BE ALLOWED PROVIDED THAT THEY ARE CONTROLLED BY AN OCCUPANT SENSOR(S) CERTIFIED TO COMPLY WITH SECTION l 19(d). l l. CEILING MOUNTED LIGHTING IN WALK-IN-CLOSET SHALL BE LOCATED A MINIMUM OF 12'' CLEAR FROM SHELVES AND SHALL BE PROTECTED(COVERED). 12. PROVIDE RECEPTACLES WITHIN 2 FEET OF KITCHEN SINK AND AT 4 FEET ON-CENTER AT COUNTERS AND ISLANDS. 13. ALL POWER AND LIGHTING OUTLETS IN BEDROOM TO BE PROTECTED BY AN ARC-FAULT INTERRUPTER(Sj CIRCUIT. 14. ANY FIXED APPLIANCE SUCH AS DISPOSAL. DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATERS, OR ANY OTHER FIXED APPLIANCE WITH ¾ H.P. MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH CIRCUIT. EACH DWELLING UNIT SHALL HAVE INSTALLED THEREIN AN INDIVIDUAL DISPOSAL CIRCUIT SUPPLIED WITH MINIMUM #12 AWG WIRE AND A 15 AMP INDICATING-TYPE SWITCH 2 D/ W (E) GATE SHEET NUMBER SHEET TITLE PROJECT ADDRESS ISSUE FOR STAMP CURRENT REVISION # REVISION HISTORY #REASON DATE 1 CITY CORRECTIONS 7/23/2024 2 CITY CORRECTIONS 8/20/2024 141 E SANTA CLARA STREET ARCADIA, CA 91006 FLOOR PLAN BEFORE RENOVATIONS A-1 PLAN CHECK DRAWN BY HP PRINCIPLE IN CHARGE HP DATE: Apex Properties 9055 LAS TUNAS DRIVE SUITE 200 TEMPLE CITY, CA 91780 626-590-8918 08/20/2024 TE N A N T IM P R O V E M E N T S 14 1 E S A N T A C L A R A S T R E E T AR C A D I A , C A 9 1 0 0 6 FLOOR PLAN BEFORE RENOVATIONS SCALE 1/8"=1'-0" 34'-512" 27'-2" 111'-812" 48'-9" 14' 35'-2" 4'-1" 7'-8" 7'-8" 7'-8" Ø5' 2 (E) GATE 12" DRYWALL 12" DRYWALL OPEN NON LOAD BEARING WALL SEE PLATE CONNECTION DETAILS SHEET S-1 ALL GENDER RESTROOM PLACARD ON DOORS ALL GENDER RESTROOM PLACARD ON DOORS ACCESSIBLE PLACARD ON DOOR ACCESSIBLE PLACARD ADJACENT TO DOOR 48" AFF WITH RAISED LETTERS AND BRAILLE ADA EGRESS SIGN WITH BRAILLE AND RAISED CHARACTERS 48" TO 60" AFF ADA EXIT SIGN WITH BRAILLE AND RAISED CHARACTERS 48" TO 60" AFF ADA ROOM ID SIGN WITH BRAILLE AND RAISED CHARACTERS 48" TO 60" AFF ADA ROOM ID SIGN WITH BRAILLE AND RAISED CHARACTERS 48" TO 60" AFF ACCESSIBLE ALL GENDER PLACARD ADJACENT TO DOOR 48" AFF WITH RAISED LETTERS AND BRAILLE SHEET NUMBER SHEET TITLE PROJECT ADDRESS ISSUE FOR STAMP CURRENT REVISION # REVISION HISTORY #REASON DATE 1 CITY CORRECTIONS 7/23/2024 2 CITY CORRECTIONS 8/20/2024 141 E SANTA CLARA STREET ARCADIA, CA 91006 FLOOR PLAN AFTER RENOVATIONS A-2 PLAN CHECK DRAWN BY HP PRINCIPLE IN CHARGE HP DATE: Apex Properties 9055 LAS TUNAS DRIVE SUITE 200 TEMPLE CITY, CA 91780 626-590-8918 08/20/2024 TE N A N T IM P R O V E M E N T S 14 1 E S A N T A C L A R A S T R E E T AR C A D I A , C A 9 1 0 0 6 FLOOR PLAN AFTER RENOVATIONS SCALE 1/8"=1'-0" NEW DOOR SCHEDULE NO.SIZE TYPE/MATERIAL FRAME HARDWARE TYPE A 1-3/4" X 3'-0" X 6'-8"1-3/4" SOLID CORE DOOR WOOD LATCHSET B 1-3/4" X 2'-6" X 6'-8"1-3/4" SOLID CORE DOOR WOOD LATCHSET 21'-1" 12'-812" 7'-41 2" 8' 12' A B 2 (E) GATE 12" DRYWALL 12" DRYWALL SEE PLATE CONNECTION DETAILS SHEET A-3 ALL GENDER RESTROOM PLACARD ON DOORS ALL GENDER RESTROOM PLACARD ON DOORS EXISTING 2X6 FRAMING WITH R21 NEW 2X4 FRAMING WITH R21 NEW 2X4 FRAMING NEW 2X4 FRAMING WITH SOUND INSULATION ACCESSIBLE PLACARD ON DOOR ACCESSIBLE PLACARD ADJACENT TO DOOR 48" AFF WITH RAISED LETTERS AND BRAILLE NEW 2X4 FRAMING WITH R21 EXISTING MASONRY WALLS EXISTING MASONRY WALLS EXISTING MASONRY WALLS SHEET NUMBER SHEET TITLE PROJECT ADDRESS ISSUE FOR STAMP CURRENT REVISION # REVISION HISTORY #REASON DATE 1 CITY CORRECTIONS 7/23/2024 2 CITY CORRECTIONS 8/20/2024 141 E SANTA CLARA STREET ARCADIA, CA 91006 TITLE 24 ENVELOPE A-3 PLAN CHECK DRAWN BY HP PRINCIPLE IN CHARGE HP DATE: Apex Properties 9055 LAS TUNAS DRIVE SUITE 200 TEMPLE CITY, CA 91780 626-590-8918 08/20/2024 TE N A N T IM P R O V E M E N T S 14 1 E S A N T A C L A R A S T R E E T AR C A D I A , C A 9 1 0 0 6 NEW TITLE 24 ENVELOPE SCALE 1/8"=1'-0" 2 HONEYCOMB HATCH IDENTIFYING PRESCRIPTIVE T24 AREA 1 SOLE PLATE CONNECTION DETAIL - 1"=1'-0" WALL ENVELOPE SECTION DETAILS 1/2" GYPSUM BOTH SIDES R21 INSULATION 2X6 FRAMING WITH R21 2X4 FRAMING ALONG EXISTING MASONRY WALLS 1/2" GYPSUM ONE SIDE EXISTING EXTERIOR MASONRY WALLS SHEET NUMBER SHEET TITLE PROJECT ADDRESS ISSUE FOR STAMP CURRENT REVISION # REVISION HISTORY #REASON DATE 1 CITY CORRECTIONS 7/23/2024 2 CITY CORRECTIONS 8/20/2024 141 E SANTA CLARA STREET ARCADIA, CA 91006 DETAILS A-4 PLAN CHECK DRAWN BY HP PRINCIPLE IN CHARGE HP DATE: Apex Properties 9055 LAS TUNAS DRIVE SUITE 200 TEMPLE CITY, CA 91780 626-590-8918 08/20/2024 TE N A N T IM P R O V E M E N T S 14 1 E S A N T A C L A R A S T R E E T AR C A D I A , C A 9 1 0 0 6 1 SOLE PLATE CONNECTION DETAIL - 1 2"=1'-0" 2 RESTROOM DETAILS - 3 8" = 1'-0" RAMSET 3" DRIVE PINS OR EQ 1-3/4" MIN FROM ENDS AND 6" MAX FROM ENDS 3' MAX SPACING BETWEEN FASTENERS 1-3/8"MIN EMBEDMENT REF ICC ESR-2690 LABC SUPPLEMENT (E)CONCRETE SLAB PRESSURE TREATED GROUND CONTACT 2 X LUMBER TYP. 2 X DOUGLAS FIR LUMBER 16" CENTER TO CENTER TYP. 1'-4" TYP STAGGER BLOCKING TYP. 7'-8" 1'-934" 2'-834" 1'-6" 5'-2" 5'-334"12" 24" 17" - 18" FLUSH ACTIVATOR ON WIDE SIDEØ5' 24" MIN 7'-6" CL CL2'-7" 7'-6" 6' 3' 42" MIN 3' STANDARD AND FIRE RATED WALL DETAIL AND 1/2" GYPSUM NO SCALE NO SCALE 3 WALL SHEATHING DETAILS - NO SCALE 2 1/2" GYPSUM BOTH SIDES RAMSET 3" DRIVE PINS OR EQ CENTERED PRESSURE TREATED GROUND CONTACT 2 X LUMBER TYP. FIBERGLASS INSULATION PER PLANS FRONT VIEW SECTION VIEW USE #12-1/2 X 1-1/4 IN DRYWALL NAILS, TYP. RAMSET POWDER ACTUATED NAIL SPECS 120" PARTITION HEIGHT A.F.F. E COLORADO BLVDE COLORADO BLVD N 1 S T A V E N 1 S T A V E N 1 S T A V E LA PORTE ST LA PORTE ST E SAINT JOSEPH ST E SAINT JOSEPH ST N 2 N D A V E N 2 N D A V E N 2 N D A V E E SAINT JOSEPH ST TE N A N T I M P R O V E M E N T F O R O F F I C E RA Y L I U A S S O C I A T E S , C O R P . ϯϰ ϱ Ϯ    ^ d  & K K d , / > >   K h >  s  Z  ͕  ^ h / d   ϲ Ϯ Ϭ W ^    E  ͕     ϵ ϭ ϭ Ϭ ϳ d͘ ϲ Ϯ ϲ Ͳ ϱ Ϯ ϵ Ͳ ϯ ϴ ϱ ϴ   & ͘ ϲ Ϯ ϲ Ͳ ϱ Ϯ ϵ Ͳ ϯ ϰ ϲ ϴ    D  / > ͗ Z  z Λ Z  z > / h  ^ ^ K  /  d  ^ ͘  K D S-1 ST R U C T U R A L P L A N S & D E T A I L S TE N A N T I M P R O V E M E N T F O R O F F I C E RA Y L I U A S S O C I A T E S , C O R P . ϯϰ ϱ Ϯ    ^ d  & K K d , / > >   K h >  s  Z  ͕  ^ h / d   ϲ Ϯ Ϭ W ^    E  ͕     ϵ ϭ ϭ Ϭ ϳ d͘ ϲ Ϯ ϲ Ͳ ϱ Ϯ ϵ Ͳ ϯ ϴ ϱ ϴ   & ͘ ϲ Ϯ ϲ Ͳ ϱ Ϯ ϵ Ͳ ϯ ϰ ϲ ϴ    D  / > ͗ Z  z Λ Z  z > / h  ^ ^ K  /  d  ^ ͘  K D S-2 ST R U C T U R A L P L A N S & D E T A I L S REVISIONS BY REVISIONS BY REVISIONS BY REVISIONS BY REVISIONS BY