HomeMy WebLinkAbout1238 S Golden West Ave - 2024 - Medical TIXX X XX X AX.X XX AX.X XX DETAIL IDENFICATION NUMBER SHEET NUMBER SECTION REFERENCE SHEET NUMBER INTERIOR ELEVATION REFERENCE SHEET NUMBER DETAIL REFERENCE NUMBER SHEET NUMBER AX.X XX KITCHEN FIXTURE / APPLANCE REFERENCE GENERAL NOTE REFERENCE BATHROOM FIXTURE & ACCESSORIES REFERENCE LAUNDRY FIXTURE / APPLIANCE REFERENCE DOOR REFERENCE WINDOW REFERENCE SHEET NUMBER DETAIL REFERENCE NUMBER 1.THE CONTRACTOR AND/OR SUB-CONTRACTORS SHALL VISIT AND REVIEW CONDITIONS PRIOR TO SUBMITTING BIDS. 2.THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFTETY OF ALL PERSONS & PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY & NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL PROVIDE PUBLIC PROTECTION AS NECESSARY & REQUIRED BY GOVERNING CITY AGENCIES 3.THE WORK SHALL CONFIRM TO THE APPLICABLE BUILDING CODE AND OTHER ORDINANCES CODES & REGULATIONS LISTED IN THE SPECIFICATIONS OR ON THE DRAWINGS, & REGULATIONS LISTED IN THE SPECIFICATIONS OR ON THE DRAWINGS, & REQUIRED BY LOCAL BUILDING AUTHORITIES. THE GOVERNING CODES, RULES & REGULATIONS ARE COLLECTIVELY REFERRED TO AS "THE CODE". THE CONTRACTOR SHALL REPORT ANY INCONSISTENCIES, CONFLICTS OR OMISSIONS HE MAY DISCOVER TO THE ARCHITECT FOR INTERPRETATION PRIOR TO REFORMING THE WORK. 4.THE GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS & DIMENSIONS ON THE JOB SITE & REPORT ANY & ALL DISCREPANCIES AND/OR UNUSUAL CONDITIONS TO THE DESIGNER PRIOR TO FINALIZING BIDS OR COMMENCEMENT OF ANY CONSTRUCTION. 5.TRADE NAMES AND MANUFACTURES REFERRED TO ARE FOR QUALITY STANDARDS ONLY. SUBSTITUTIONS WILL BE PERMITTED WHERE SUBMITTED TO AND APPROVED BY THE OWNER & DESIGNER PRIOR TO THEIR PURCHASE AND INCORPORATION INTO THE WORK. 6.PROVIDE APPROVED FIRE EXTINGUISHERS AS REQUIRED BY FIRE MARSHALL. LOCATIONS SHALL BE DETERMINED IN THE FIELD BY THE FIRE MARSHALL. 7.THE CONTRACTOR SHALL OBTAIN & PAY FOR ALL PERMITS & VERIFY GOVERNING AUTHORITIES' REQUIREMENTS FOR CONSTRUCTION. 8.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS FOR INSPECTIONS AND/OR TESTS, UNLESS NOTED OTHERWISE. 9.ALL RAMPS SHALL HAVE A NON-SLIP FINISH. 10.DO NOT SCALE THESE DRAWINGS. SHOULD ANY DIMENSIONAL DISCREPANCIES BE ENCOUNTERED, CLARIFICATIONS SHALL BE OBTAINS FROM THE DESIGNER. 11.UNLESS OTHERWISE NOTED ON THESE DRAWINGS OR IN THE SPECIFICATIONS AS BEINGS N.I.C. OR EXISTING, ALL ITEMS, MATERIALS, ETC., & THE INSTALLATION OF SAME ARE A PART OF THE CONTRACT DEFINED BY THESE DRAWING SPECIFICATIONS. 12.THE BUILDING & ITS FACILITIES SHALL BE ACCESSIBLE TO & FUNCTIONAL TO THE PHYSICALLY HANDICAPPED. 13.PROVIDE EXIT SIGNS AT ALL LEGAL EXITS AS REQUIRED BY CODE. EXIT SIGNS, WHERE, INDICATED ON PLANS, SHALL BE ILLUMINATED & READ "EXIT" IN 6" HIGH LETTERS. EXITS SIGNS SHALL BE ON CIRCUIT & INDEPENDENTLY CONTROLLED REFER TO ELECTRICAL DRAWINGS. 14.DETAILS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN. MINOR MODIFICATIONS MAY REQUIRED TO SUIT THE FIELD DIMENSIONS OR CONDITIONS & SUCH MODIFICATION SHALL BE INCLUDED AS PART OF THE WORK OF THE CONTRACT. 15.ALL INTERIOR WALL DIMENSIONS ARE TO THE FACE OF THE STUD UNLESS OTHERWISE NOTED. 16.ALL EXTERIOR WALL DIMENSIONS ARE TO FACE OF CONCRETE BLOCK OR TO FACE OF STUD, UNLESS OTHERWISE NOTED. 17.THE CLIENT, DESIGNERS, CONSULTANTS & ALL INSPECTORS FROM PERTINENT AGENCIES SHALL BE PERMITTED ACCESS TO THE JOB SITE AT ALL TIMES DURING NORMAL WORKING HOURS. 18.THE CONTRACTOR SHALL PROVIDE SOLID BLOCKING, UNLESS NOTED OTHERWISE AS REQUIRED FOR NAILING OF ALL INTERIOR & EXTERIOR TRIMS, FINISHES, AND SHALL PROVIDE FOR ALL THE NECESSARY FRAMING & BRACING FOR THE INSTALLATION FOR N.I.C. EQUIPMENT INDICATED. 19.PROVIDE VENTILATION FOR ALL ELECTRICAL & TELEPHONE EQUIPMENT ROOMS. 20.MECHANICAL VENTILATION SHALL SUPPLY A MINIMUM 5 CFM OF OUTSIDE AIR, EXCEPT IN TOILET ROOMS WHERE FIVE (5) AIR CHANGES PER HOUR SHALL BE PROVIDED. SYSTEM MUST PROVIDE A TOTAL CIRCULATION OF NOT LESS THE 15 CUBIC FEET PER MINUTES PER OCCUPANT IN ALL PORTIONS OF THE BUILDING. REFER TO MECHANICAL DRAWINGS. 21.PROVIDE METAL TRIM OR CASING AT ALL EDGES OF PLASTER OR DRYWALL WHERE IT TERMINATES OR MEETS ANY OTHER MATERIAL EXCEPTS FLOORS. 22.THE CONTRACTOR SHALL VERIFY LOCATION & SIZE OF ALL FLOOR, ROOF, & WALL OPENINGS WITH ALL APPLICABLE DRAWINGS. 23.KEEP PIPING AS CLOSE TO WALLS & AS HIGH TO UNDERSIDE OF ROOF FRAMING AS POSSIBLE. 24.WHERE LARGER STUDS OR FURRING ARE REQUIRED TO COVER DUCTS, PIPING CONDUITS, ETC., THE LARGER STUD OR FURRING SHALL EXTEND THE FULL LENGTH OF THE SURFACE INVOLVED. 25.THE CONTRACTOR SHALL VERIFY INSERTS & EMBEDDED ITEMS W/ALL APPLICABLE DRAWINGS BEFORE POURING CONCRETE. 26.ALL EXTERIOR EXPOSED METAL (TRIMS, RAILING, FRAMES, MOLDINGS ETC.) SHALL BE PAINTED, UNLESS NOTED OTHERWISE. 27.IN ALL CASES, PROVIDE ISOLATION OF ALUMINUM FROM ADJACENT STEEL OR COAT SURFACES IN CONTACT WITH BITUMINOUS PAINT. 28. ALL EXTERIOR WALL OPENINGS, FLASHING, COPING, & EXPANSION JOINTS SHALL BE WEATHERPROOF. 29.ALL ROOF DRAINS SHALL BE LOCATED AT THE LOWEST POINT OF THE ROOF TAKING INTO CONSIDERATION THE CAMBER OF BEAMS & DEFLECTION OF CANTILEVERS. CONTRACTOR SHALL VERIFY THAT POSITIVE DRAINAGE EXISTS FROM ALL POINTS ON ROOF PRIOR TO INSTALLING DECK. 30.SIZES OF MECHANICAL EQUIPMENT PADS, BASES, ROOF EQUIPMENT PAD, & OPENINGS ARE BASIS FOR DESIGN ONLY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS OF ALL EQUIPMENT PADS & BASES WITH EQUIPMENT MANUFACTURERS. MECHANICAL CONTRACTORS SHALL VERIFY ALL SIZES & LOCATIONS OF DUCT OPENINGS ON ROOF. 31.WATER HEATER MUST BE STRAPPED TO WALL. 32. GLAZING NOTES: A: ALL FIXED & OPENABLE WINDOWS FROM ZERO TO 50 SQ. FT. IN AREA SHALL HAVE x" MINIMUM GLASS GRIP & u" MINIMUM GLASS EDGE CLEARANCE B: ALL FIXED & OPENABLE WINDOWS OVER 50 SQ. FT. IN AREA SHALL HAVE i" MINIMUM GLASS GRIP & u" MINIMUM GLASS EDGE CLEARANCE. C: GLAZING IN ALUMINUM DOORS SHALL HAVE i" MINIMUM GLASS GRIP & e" MINIMUM GLASS EDGE CLEARANCE. D: ALL WINDOWS & DOOR GLAZING SHALL HAVE CONTINUOUS GLAZING RABBET & GLASS RETAINER & RESILIENT SETTING MATERIAL.. 33. SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH 2013 CBC SECTION 1605A.3.1 34. THE BUILDING SHALL BE COMPLETELY SPRINKLED WITH AN AUTOMATIC FIRE EXTINGUISHING SYSTEM AS APPROVED BY THE GOVERNING FIRE DEPARTMENT, BUILDING DEPARTMENT, AND THE OWNER'S FIRE INSURANCE RATING BUREAU. COPIES OF FIRE DEPARTMENT & INSURANCE BUREAU APPROVED PLANS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR CHECKING & APPROVAL PRIOR TO INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN & CONSTRUCTION OF A COMPLETE SYSTEM, FROM CONNECTION TO THE SITE WATER MAIN (OR SITE FIRE SERVICE VAULT WHERE PROVIDED) TO THE BUILDING INTERIOR SPRINKLER DISTRIBUTION. REFER TO SITE UTILITY PLANS. ALL SPRINKLER LINES SHALL RUN CONCEALED IN ALL FINISHED, AREAS, INTERFERENCE WITH LIGHTS, DUCTS, PIPES, ETC,. SHALL BE AVOIDED. EXPOSED PIPING IN FINISHED AREAS WILL NOT BE ACCEPTABLE. AUTOMATIC FIRE EXTINGUISHERS SYSTEM MUST BE FULLY OPERATIONAL & ENERGIZED PRIOR TO FIXTURIZATION OF THE BUILDING. 35. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND / OR ADDITIONAL EXPENSES. 36. AN APPROVED SEISMIC GAS SHUT OFF VALVE OR EXCESS FLOW SHUT OFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN-STEAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING." (PER ORDINANCE 170, 158 AND 180,670) (INCLUDES COMMERCIAL ADDITIONS AND TI WORK OVER $10,000.) SEPARATE PLUMBING PERMIT IS REQUIRED. 37. PROVIDE ULTRA-FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. AC. T.-ACOUSTIC TILE. AFF -ABOVE FINISH FLOOR ALT -ALTERNATE ALUM -ALUMINUM ANCH -ANCHOR APPROX -APPROXIMATELY ARCH -ARCHITECT/ARCHITECTURAL BR. CS.-BRICK COURSE BLDG -BUILDING BLK -BLOCK B.M.-BENCH MARK BM -BEAM B.N.-BULL NOSE BNT -BENT BMT -BOTTOM C.B.-CATCH BASIN CEM -CEMENT CER. T.-CERAMIC TILE C.J.-CONTROL JOINT CLR.-CLEAR CLG -CEILING CMU -CONCRETE MASONRY UNIT COL -COLUMN COMP.-COMPOSITION CONC.-CONCRETE CONSTR.-CONSTRUCTION CONT.-CONTINUOUS CONTR.-CONTRACTOR CTR.-CENTER DET.-DETAIL D.F.-DRINKING FOUNTAIN DIA. -MIAMETER DIM -DIMENSION D.O.-DOOR OPENING DS -DOWNSPOUT DWG -DRAWING EIFS -EXT. INSULATION & FINISH SYSTEM EL -ELEVATION (SEA LEVEL) ELEC.-ELECTRICAL ELEV.-ELEVATION EXP -EXPANSION E.J.-EXPANSION JOINT EXT -EXTERIOR F.D.-FLOOR DRAIN F.E.-FIRE EXTINGUISHER FIN -FINISH FLR -FLOOR FDN -FOUNDATION FOM -FACE OF MASONRY FPHB -FROST PROOF HOSE BIBB F.S.-FULL SIZE OR FLOOR SINK FTG -FOOTING FURR -FURRING FAC -FIRE VALVE CABINET GA.-GAUGE GALV.-GALVANIZED GEN -GENERAL GRFC -GLASS FIBER REINFORCED CONCRETE GRFG -GLASS FIBER REINFORCED GYPSUM GL -GLASS/GLAZING G.S.-GRAVEL STOP GYP.BD.-GYPSUM BOARD HDWE -HARDWARE HB -HOSE BIBB H.M.-HOLLOW METAL HYD -HYDRANT I.D.-INSIDE DIAMETER INSUL -INSULATION JT -JOINT LAV -LAVATORY LG.-LONG LLH -LONG LEG HORIZONTAL LLV -LONG LEG VERTICAL L.P.-LOW POINT/LIGHT PANEL LT -LIGHT MAR -MARBLE MAS -MASONRY MAX -MAXIMUM MECH.-MECHANICAL MTL -METAL MFR -MANUFACTURER MH -MANHOLE MIN.-MINIMUM MISC.-MISCELLANEOUS M.O.-MASONRY OPENING METTHRES.-METAL THRESHOLD NIC -NOT IN CONTRACT NO -NUMBER O/A -OVERALL O/C -ON CENTER O.D.-OUTSIDE DIAMETER OH -OVERHELD O/O -OUT TO OUT OPNG -OPENING PC -PIECE PL -PLATE PLAS -PLASTER PLBG -PLUMBING NUMBER PLYWD -PLYWOOD POL -POLISHED PROJ -PROJECT PTD -PAINTED R -RADIUS RAILG -RAILING R.D.-ROOF DRAIN REINF.-REINFORCEMENT/REINFORCED REQD.-REQUIRED RM -ROOM R.O.-ROUGH OPENING S -SINK SHT.-SHEET S.M.-SHEET METAL SQ.-SQUARE SPM -SINGLE PLY MEMBRANE S.S.-SLOP/SERVICE SINK ATTACHMENT A: 1238 S GOLDEN W AVE, ARCADIA, CA 91007 1.TENANT IMPROVEMENT FOR NEW USE AS MEDICAL OFFICE (ACUPUNCTURE) GENERAL NOTES: SCOPE OF WORK: GENERAL NOTES: ABBREVIATIONS: FIRE NOTES: SHEET INDEX: PROJECT DATA: ZONE: OCCUPANCY GROUP: CONSTRUCTION TYPE:FIRE SPRINKLERS: # OF STORIES OF THE BUILDING: General Commercial (C-G) B V-B YES 1 A1 TITLE SHEET & PROJECT DATA A2 HANDICAPPED NOTES & DETAILS A3 SITE PLAN A4 EXISTING FLOOR PLAN & REFLECTED CEILING PLAN A5 PROPOSED FLOOR PLAN A6 PROPOSED REFLECTED CEILING PLAN & EGRESS PLAN GN1 CALGREEN DATA GN2 CALGREEN DATA GN3 CALGREEN DATA AD ARCHITECTURAL DETAILS E1 ELECTRICAL E2 ELECTRICAL P1 PLUMBING P2 PLUMBING M1 MECHANICAL M2 MECHANICAL M3 MECHANICAL CONSULTANTS DESIGNER: YWR ARCHITECTS 229 S. MISSION DR. SAN GABRIEL, CA 91776 TEL: 510-850-4043 E-MAIL: shin@ywrising.com APPLICABLE BUILDING CODE 2023 LACC, LOS ANGELES COUNTY CODE 2023 CFC, CALIFORNIA FIRE CODE 2023 CPC, CALIFORNIA PLUMBING CODE 2023 CMC, CALIFORNIA MECHANICAL CODE 2023 CEC, CALIFORNIA ELECTRICAL CODE 2023 CALIFORNIA ENERGY CODE, 2023 CALIFORNIA GREEN CODE 2023 CALIFORNIA BUILDING STANDARDS CODE LEGAL DESCRIPTION: TOTAL BUILDING AREA:28,175 SQ.FT. OCCUPANT LOAD:23 1.ALL CODE REFERENCES ARE TO BE IN COMPLIANCE WITH THE HEALTH & SAFETY CODE (HSC) SECTION 13145, CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 19; TITLE 24, 2023 EDITION: ·PART 1, CALIFORNIA ADMINISTRATION CODE (CAC) ·PART 2, CALIFORNIA BUILDING CODE (CBC) ·PART 3, CALIFORNIA ELECTRICAL CODE (CEC) ·PART 4, CALIFORNIA MECHANICAL CODE (CMC) ·PART 5, CALIFORNIA PLUMBING CODE (CPC) ·PART 6, CALIFORNIA ELEVATOR CODE (CELVC) ·PART 9, CALIFORNIA FIRE CODE (CFC) 2.FIRE DEPARTMENT INSPECTION AREA REQUIRED. SCHEDULE ALL INSPECTIONS 72 HOURS IN ADVANCE. 3.REGARDLESS OF THE OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPEN ABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. KEY - LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHERE THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS". 4.EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL. NO POINT SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES. ALL EXIT SIGN SHALL BE ILLUMINATED AT ALL TIMES, TO ENSURE CONTINUED ILLUMINATION FOR A DURATION OF NOT LESS THAN 1 1/2 HOURS IN CASE OF PRIMARY POWER LOSS. 5.MEANS OF EGRESS SHALL BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOT CANDLE AT THE FLOOR LEVEL. EMERGENCY ILLUMINATION SHALL BE PROVIDED IN CASE OF POWER FAILURE. 6.IN ASSEMBLY OCCUPANCY THE CAPACITY OF ROOM SHALL BE POSTED IN A CONSPICUOUS PLACE ON AN APPROVED SIGN NEAR THE MAIN EXIT & EXIT - ACCESS DOORWAY. CBC SECTION 1007.2.6 7.PLANS OF NEW OR MODIFICATIONS TO EXISTING FIRE PROTECTION, DETECTION, ALARM OR MONITORING SYSTEM (S) SHALL BE APPROVED BY FIRE DEPARTMENT WITHIN 30 DAYS OF THE ISSUANCE OF THE BUILDING PERMIT. 8.IN ADDITIONS OF WALLS AND / OR OTHER TENANT IMPROVEMENTS OBSTRUCT OR EFFECT COVERAGE OR PERFORMANCE OF THE SPRINKLER SYSTEM AND/ OR IF ANY MODIFICATIONS TO THE FIRE SPRINKLER SYSTEM IS NECESSARY, FIRE SPRINKLER TENANT IMPROVEMENT PLANS SHALL BE SUBMITTED TO THE CITY 9.LOCATION(S) AND CLASSIFICATION(S) OF FIRE EXTINGUISHERS SHALL BE IN ACCORDANCE WITH THE CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 19 AND THE CALIFORNIA FIRE CODE STANDARD 10-1 AND PLACEMENT IS SUBJECT TO THE FIRE INSPECTOR PRIOR TO FIRE CLEARANCE FOR THE CERTIFICATE OF OCCUPANCY TO BE ISSUED BY THE BUILDING DEPARTMENT. CFC CHAPTER 10. 10.HVAC UNIT OR SYSTEM > 2000 CFM SHALL HAVE AUTOMATIC SMOKE DUCT DETECTORS INSTALLED AND CONNECTED TO THE BUILDING FIRE ALARM SYSTEM. CMC SECTION 608. OWNER: JACKIE ZHANG 1238 S GOLDEN WEST ARCADIA, CA, 91007 TEL: 626-268-7798 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT IMPROVEMENT AREA:1,003 SQ.FT. FIRE NOTES: (CONTINUED) 11.THE CONTRACTOR SHALL ADHERE TO THE 2022 CALIFORNIA FIRE CODE, CHAPTER 33 REGULATIONS DURING DEMOLITION, ALTERATION, AND CONSTRUCTION OF THE BUILDING. 12.SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE FIRE OFFICIAL HAS APPROVED THE SUBMITTAL DOCUMENTS. 13.THE FOLLOWING ARE DEFERRED SUBMITTALS: - FIRE SPRINKLER SYSTEM TENANT IMPROVEMENT. 14.BEFORE MAKING A REQUEST FRO A FIRE INSPECTION, PLEASE READ AND COMPLY WITH THE APPLICABLE SAN JOSE FIRE DEPARTMENT NOTES. ADDITIONALLY, THE PERSON REQUESTING THE INSPECTION IS RESPONSIBLE FOR MEETING THE INSPECTOR ON TIME, PROVIDING ACCESS TO THE AREA REQUIRING INSPECTION AND HAVING AN APPROVED SET OF PLANS AND SUPPORTING DOCUMENTS AVAILABLE AT THE TIME OF THE INSPECTION. 15.A FIRE INSPECTION AND FINAL APPROVAL IS REQUIRED BEFORE THE BUILDING DEPARTMENT WILL ACCEPT A BUILDING FINAL INSPECTION REQUEST. PLEASE FAX IN YOUR INSPECTION REQUEST TO THE SAN JOSE FIRE DEPARTMENT, FIRE PREVENTION DIVISION AT (408)535-3555 ON OUR INSPECTION REQUEST FORM. THE PERSON DOING THE WORK AUTHORIZED BY A PERMIT SHALL NOTIFY THE FIRE DEPARTMENT THAT SUCH WORK IS READY FOR A FIRE INSPECTION. 16.FIRE DEPARTMENT ACCESS ROADS AND PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AND MAINTAINED DURING CONSTRUCTIONS, ALTERATION OR DEMOLITION OF A BUILDING. CFC 3310.1&3315 17.FIRE EXTINGUISHERS MUST BE INSTALLED PER CFC SECTION 906. START THE PLACEMENT OF FIRE EXTINGUISHER NEAR THE EXTERIOR EXIT DOORS. MOUNT THE FIRE EXTINGUISHER IN A VISIBLE AND ACCESSIBLE LOCATION, 3-1/3' TO 5' ABOVE THE FINISH FLOOR TO THE HANDLE. BUILDINGS WITH MULTIPLE FLOORS MUST HAVE AT LEAST ONE FIRE EXTINGUISHER PER FLOOR. - LIGHT HAZARD (OFFICES, CLASSROOMS, CHURCHES, ASSEMBLY ROOMS, RESIDENTIAL) OCCUPANCIES REQUIRE "2A10BC" FIRE EXTINGUISHERS. THE MAXIMUM COVERAGE AREA IS 5,000 SF PER EXTINGUISHER AND THE MAXIMUM TRAVEL DISTANCE IS 75'. 18.THE FIRE SPRINKLER SYSTEM REQUIREMENTS AND/OR MODIFICATIONS REQUIRE A SEPARATE PLAN CHECK SUBMITTAL AND APPROVAL. WORK SHALL NOT COMMENCE UNTIL A PERMIT IS OBTAINED. INSPECTION OF THE ROUGH PIPING MUST BE PERFORMED PRIOR TO CONCEALMENT; A LIFT IS REQUIRED FOR MOST INSPECTIONS. CEILING TILES MUST NOT BE INSTALLED UNLESS APPROVED BY THE FIRE INSPECTOR. 19. THE FIRE ALARM SYSTEM REQUIREMENTS AND/OR MODIFICATIONS REQUIRE A SEPARATE PLAN CHECK AND APPROVAL. WORK SHALL NOT COMMENCE UNTIL A PERMIT IS OBTAINED. 20.IN OCCUPANCY GROUP B, KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON, OR ADJACENT TO, THE DOOR STATING "THIS DOOR MUST REMAIN UNLOCKED WHILE THE BUILDING IS OCCUPIED". THIS SIGN SHALL BE IN LETTERS NOT LESS THAN 1-INCH HIGH ON A CONTRASTING BACKGROUND. WHEN UNLOCKED, THE SINGLE DOOR OR BOTH LEAVES OF A PAIR OF DOORS MUST BE FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE. THE USE OF THIS EXCEPTION MAY BE REVOKED BY THE CHIEF FOR DUE CAUSE. CFC 1010.1.9.3 21.ALL DOORS DESIGNATED AS EXITS, EXCEPT FOR THE MAIN ENTRANCE IN B OCCUPANCIES, MUST BE EQUIPPED WITH PANIC OR LEVER TYPE HARDWARE. CFC 1010.1.9 22.ADDITIONAL EXIT SIGNS MAY BE REQUIRED AT THE TIME OF FINAL INSPECTION, IF THE ONES SHOWN ON THE PLANS DO NOT MEET THE INTENT OF THE CODE. CFC 1013.1 23.IF AS-BUILT PLANS ARE REQUIRED, ADDITIONAL FEES WILL BE DUE FOR REVIEW OF THE AS-BUILT PLANS. MEP ENGINEER: JS ENGINEERING INC., 410 S. SAN GABRIEL BLVD, STE #8, SAN GABRIEL, CA 91776 TEL: 626-497-0558 EMAIL: joezhang@sbcgobal.net VICINITY MAP: S. STL -STAINLESS STEEL STD -STANDARD STRUCT.-STRUCTURAL SUSP -SUSPENDED T/-TOP OF T.D.-TRENCH DRAIN TERR -TERRAZZO TYP -TYPICAL VCT -VINYL COMPOSITION TILE W.C.-WATER CLOSET WD -WOOD WT -WEIGHT WWF -WELDED WIRE FABRIC DEFERRED SUBMITTAL: 1. EXISTING FIRE SPRINKLER SYSTEM UPGRADE (WHEN REQUIRED) APN: 5383-035-014 SANTA ANITA LAND CO'S TRACT N 300 FT OF W 378 FT OF LOT 3 BLK A REFERENCE SYMBOL: BUSINESS:ACUPUNCTURE & PHYSICAL THERAPY OSHPD 3 APPLICABLE:NO X-RAY:NO A1 SITE TITLE SHEET & PROJECT DATA 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising A2 ENTRANCES & EXITS, DOORS All entrances and exterior ground-floor exit doors to1. persons with disabilities. Exit doors shall be readily operable from the egress side without the use of a key or special knowledge Hand-activated door opening hardware shall be centered between 34 inches and 44 inches above the floor. Latching and locking doors that are hand- activated and which are in a path of travel shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars, or other hardware designed to provide passage. Locked exit doors shall operate as above in egress inches measured between the face of the door and the lower then the threshold of the doorway. Every required exit doorway shall be of a size as to permit the installation of a door not less than 3 feet in width and not less than 6 feet 8 inches in height. When installed in exit doorways, exit doors shall be capable of opening at least 90 degrees and shall be so mounted that the clear width of the exit way is not less than 32 The floor or landing shall not be more than 1/2 inch The level area shall have a length in the direction of door swing of at least 60 inches and the length opposite the direction of door swing of 48 inches as direction. closed position. strike edge for interior doors. The width of the level area on the side to which the door swing shall extend 24 inches past the strike edge of the door for exterior doors and 18 inches past the Maximum effort to operate doors shall not exceed 5 pounds for exterior and interior doors, such pull or push effort being applied at right angles to hinged doors and at the center plane of sliding or folding doors. Compensating devices or automatic door operators may be utilized to meet the above standards. When fire doors are required, the max. effort to operate the door may be WALKS & SIDEWALKS administrative authority, not to exceed 15 pounds. The bottom 10 inches of all doors except automatic and sliding doors shall have a smooth, uninterrupted surface to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. Walks and sidewalks shall have a continuous common surface, not interrupted by steps or by abrupt changes in level exceeding 1/2", and shall be a minimum of 48" increased to the min. allowable by the appropriate measured at right angles to the plane of the door in its Counters D. has the following: Clear floor space a min. of 30" x 48". Food Service Lines/Aisles Counters that exceed 34" in height, where food or Drink is served, have a minimum 60" long portion that Top Coounter is between 28"-34" above the finish floor. Knee clearance a min. 27" high, 30" wide and 19" deep Clear floor space adjoins an accessible route. J. 60" Tray slides are mounted a max. of 34" above floor. Minimum clear width of 36" is provided. (42" preferred).I. Fig. 5 B RESERVED 1/2" RADIUS WHITE REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL WITH BEADED TEXT BLUEA SIGNAGE DOOR-MOUNTED 1 1/2" ABSOLUTE 1 1/4"-1 1/2" DIAMETER 12" 1. 9. 8. 7. 6. 5. 4. 2. 3. buildings and facilities shall be made accessible toHANDICAPPED ACCESSIBILITY STANDARDS 19" D.30" W. A. Seating Wheelchair clear floor space. Ground. DINING. BANQUET AND BAR FACILITIES At least 5%, but not less than one of the seating spaces in each functional area is accessible Min. 30" x 48" clear floor spaces is provided. One full-unobstructed side of the clear floor space Knee space at tables is at least 27" H Adjoins or overlaps an accessible route or another Height of tables between 28"-34" from the floor or C. Public transportation stops Accessible parking spaces Entrance signage Accessible seating space as for the public. SITE ACCESSIBLE ROUTE OF TRAVEL At lease one accessible route within the boundary of the state is provided to an accessible building entrance from: Accessible passenger loading zones Public streets and sidewalks Main aisles a min. of 36" in width. Equivalent services and decor are provided at Access to accessible seating space(s) is provided byB. F. front of the watercloset. G. H. J. I. thick with thick1/4" No door shall encroaches into required 60" clear space Min. 60" wide and 48" deep clear floor space is provided in The centerline of the water closet fixture shall be 18" from Provide a Min. 28" wide clear floor space if water closet is water closet is adjacent to a wall or partition. adjacent to a fixture or a Min. 32" wide clear floor space if the The height of accessible water closets shall be a 17" - 19" for more than 12" M. N. L.from the floor. Q. P. (i.e. Men's O. 44" max. from floor to flush valve. 5 Lb.Max. force to operate flush valve. Walls within compartments shall be smooth,hard and non- absorbent to 48" in height, and are not adversely affected by moisture. Floor surfaces of toilet room are smooth, hard and non-absorbent extending upward a minimum of 5" beyond the front of the water closet. The forward end of the side grab bar is a located a minimum of 54" from the back wall. onto walls. Controls for the flush valve shall be mounted on the wideK. Side grab bar is a minimum 42" long and extends 24' comply with the requirements: appropriate signage. junction along or leading to an accessible route of travel, there shall be a sign displaying the international symbol of accessibility. Signs shall indicate the direction to accessible building entrances and facilities and shall Accessible entrances and routes of travel have WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR CLEAR OF DOOR-SWING. MOUNT AT 60" TO CENTERLINE OF SIGN FRON FLOOR. LETTERING RAISED DOOR MOUNTED SIGNAGE (TYP.) NOTE: PICTOGRAMS AND/OR LETTERING ARE NOT REQUIRED ON DOOR-MOUNTED SIGNAGE. U. wall. S. T.are sans-serif high and a5/8" W. V. Rear grab bar is a minimum 36" long. Rear grab bar begins a maximum of 6" from the corner of the wall on the toilet side. Diameter of grab bar(s) is 1-1/4" - 1-1/2". Grab bars are mounted at 33" to center of bar above allowed if tank obstructs placement of bar). Y. Z. AA. 30" x 48"to DD. CC. 60" BB. Min. structural strength of grab bar(s) will support a 250 lb.Point load. Grab bars do not rotate within their fittings. or abrasive elements. Toilet paper dispenser is located on the wall within 12" of the front dege of the toilet seat. 19" minimum height from floor to centerline of toilet Toilet paper dispenser allows continuous paper flow and does not control delivery. Bars are smooth with a min. radius of 1/8".X. Clearance between the grab bar(s) and wall is 1-1/2". and parallel to floor.(For tank type toilets, 36" may be Surface of wall adjacent to grab bar(s) is free of sharp paper dispenser.(location below grab bar suggested) Side grab bar begins a maximum of 12" from the rearR.At every primary public entrance and at every major A. (for sanitary facilities) DOOR MOUNTED SIGNAGE diameter circle 1/4"C. D. (Unisex)-12" B. F. E. Wall Mounted Signage Signs are centered on the door G. H. Restroom, etc.), accessibility. in height.minimum of 6" I. J. 2) Braille. Letters and numerals are raised K. door. high.maximum of 2" A. B. C. release) accessible route in facility shall be 36" Entry door has privacy latch D. E. room. of 27". 60" (See Fig.2 and Fig.3) the color and contrast of the wall. protruding objects or standing within the swing of a SINGLE ACCOMMODATION TOILETS Except at doors, the minimum clear width of an (push button-lever Sufficient space for wheelchair measuring enter room and permit the door to close is provided. A clear space of sufficient size top inscribe a diameter circle is provided within the sanitary facility space is clear of objects from the floor to a height The international symbol of accessibility is installed on the wall adjacent to the latch side of the door. The border dimension of this pictogram shall be a The characters and background of the sign is eggshell,matte, or other non-glare finish and the color and contrast of the sign distinctively contrasts with uppercase characters and are accompanied by (Grade Mounting locations allows a person to approach within 3" of the signage without encountering is placed directly below the symbol of Signs are centered on the wall 60" from the floor. Characters are minimum 1/32", Verbal description as to restroom usage IDENTIFICATION SYMBOLS (Women's) - 12" diameter circle 1/4" thick with 1/4" thick triangle superimposed within circle. (Men's) - Equilateral triangle 1/4" thick with edges 12" The characters and background of the sign is eggshell, matte, or other non-glare finish and the color and contrast of the sign distinctively contrasts with triangle superimposed within circle. the color and contrast of the door. 60" long and a vertex pointing upward. INTERNATIONAL SYMBOL OF ACCESSIBILITY exceed 1/4" per foot. exceeds 1 unit vertical to 20 unit horizontal Walk and sidewalk surface cross slopes shall not Accessible parking spaces shall be located as near as practical to a primary entrance Where single spaces are provided, they shall be 14 When the slope in the direction of travel of any walk passenger side of the vehicle. accessible as required by 1129B.4 All such spaces may be and a 5-foot loading and unloading access aisle on the forward in to the parking space and shall be designated van The sign shall not be smaller than 70 square inches in area and, when in path of travel, shall be posted at a feet wide and lined to provide a 9-foot parking area unobscured by a parked vehicle. below the symbol of accessibility. and conspicuously states the following: or sidewalk. sign to the parking space finished grade and shall be Signs may also be centered on the wall at the interior end of the parking space at a minimum 36 inches wide 36 inches high from the parking space finished grade, ground Spaces complying with 1129B.3 item 2 shall have an additional sign stating "Van-Accessible" mounted The sign shall not be less than 17" x 22" in size with lettering not less than 1-inch in height, which clearly ELECTRICAL All new and relocated electrical switches and controls/mounting heights/disabled access: Controls and switches intended to be used by occupants of the room or area are to be located: accessible spaces not displaying distinguishing placards or license plate issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at "Unauthorized vehicles parked in designated minimum height of 80 inches from the bottom of the HANDICAPPED LETTERING ON SIGN MUST BE A MINIMUM OF 1" IN. HEIGHT UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENCE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT MUST BE INCLUDED ON SIGN (MINIMUM OF 1" IN. HEIGHT) TOWED VEHICLES MAY BE RECLAIMED AT OR BY TELEPHONING OWNER'S EXPENSE. APPROPRIATE INFORMATION Fig. 6 36" 36" 22" MIN. NOTE: Fig. 3Fig. 2 H J C 36 " G 3'- 4 " M A X . 17"-19" 7"-9" WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE (CENTERED AT ENTRANCE TO STALL RECOMMENDED) SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE. AREA OF SIGN TO BE A MIN. OF 70 SQ. IN. DESIGNATE FOR "VAN ACCESSIBLE" WHERE APPROPRIATE. EMBLEM MUST BE LOCATED IN STALL SO THAT IS VISIBLE BY A TRAFFIC ENFORCEMENT OFFICER 34" TO 3'-8" A.F.F.LEVER FINISH FLOOR LEVEL DOOR HARDWARE10" MIN. BOTTOM RAIL OR PROVIDE KICK PLATE 1/2" MAX. THRESHOLDS 2 1 1/4" MAX. BELOW THRESHOLD CLEAR AT EXTERIORPULL SIDE 24" MIN. COMPRESSED CARPET 1/4" MAX. CLEAR AT INTERIOR DOORS 18" MIN. DOORS E 2 6'-6" MIN. ELEVATION 24"MIN 3'-6" MIN 7' - 0 " M I N . 32 " C L E A R 60 " M I N . 4'-0" MIN. E 2 1 E 5'-0" CLR. 30"x48" RUBBER BUMPER ON CHAIR ACCESSIBLE PARKING REQUIRED 1 in every 8 accessible spaces, but not less than 1, shall be served by an access aisle 96 inches wide min. placed on the side opposite the driver's side when the vehicle is going 1. 4. 3. PARKING SIGN 2. 1. VAN SPACE 2. 1. 3. 2. 3.2 No more than 15-inches, measured from the bottom of the outlet box, to the level of the finished floor or working platform. Fig. 7 PUSH SIDE 12" MIN. ADDITIONAL SPACE WITH BOTH A LATCH AND A CLOSER. IF DOOR IS EQUIPPED Fig. 4 PLAN VIEW 3.1 No more than 48-inches, measured from the top of the outlet box, and; PROVIDE THIS 48 " M I N . GRADE II BRAILLE CORRESPONDING HEIGHT OF LETTERING 5/8" MIN. TO 2" MAX. D CHARACTERS UPPERCASE JF 4' - 0 " B 3'- 4 " M A X . A E 9" M I N . 2' - 1 0 " M A X . 3'- 4 " M A X . 2'- 5 " M I N . on either side is of no consequence; the min. required clearances must be provided. To prevent possible problems, it is highly recommended that plan drawings specify lavatory models that provide a full 8" clearance from the front of the unit to any piping and additionally provides for a max. allowable bowl depth of 6-1/2". different and should not be confused. Although California's accessibility guidelines do not presently contain specific guidelines for sinks, the ADAAG does. sinks require min. knee clearances that are min. of 30" an individual's knees may be able to slip past the piping C. B. A. must maintain an absolute distance of 19" from the front of the sink. In addition, federal guidelines restrict each sink to a max. depth of 6-12" for applicable requirement. ACCESSORIES IN SANITARY FACILITIES Minimum 30" x 48" clear floor or ground space is provided to allow forward or parallel approach to One full unobstructed side of the clear floor or ground spaces adjoins or overlaps an accessible route or adjoins wheelchair clr. fl. Space. Mirror(s) is mounted with the bottom edge on higher Accessories. wide by 27" high, however the depth of this clearance The required clearances between lavatories and sinks are Lavatories require min. knee clr. of 30"(w) x 27"(h) x 8"(d); E 1 MI N 1 7 " T O M A X 1 8 " A UNDER LAVATORY. LAVATORY: B C WATER CLOSET: GRAB BAR: ELEVATION 1. NO SHARP OR ABRASIVE SURFACES 2. LEVER FAUCET CONTROLS OPERABLE. WITH ONE HAND AND 5 LBS. MAXIMUM FORCE. 3. HOT WATER SUPPLY AND DRAIN PIPING INSULATED. 1. FLUSH CONTROL HANDLE ON WIDE SIDE WITH 3 LBS. MAXIMUM OPERATING FORCE. 36 " M I N . 18 " M I N OF BARS. F G D E MIRROR PAPER TOWEL DISPENSER. TOILET PAPER HOLDER. SOAP DISPENSER. 1-1/2" CLEARANCE (FOR TANK TYPE TOILETS. 36" ABOVE FLOOR MAY BE ALLOWED IF TANK OBSTRUCTS PLACEMENT OF BARS). 2. PROVIDE SOLID BACKING FOR MOUNTING 3. NO ROTATION PERMITTED IF FITTINGS USED. 1. 1-1/4" TO 1-1/2" ROUND STEEL BARS WITH etc.). D. F. G. E. Operable parts (including coin slots) of all fixtures or accessories are located a maximum of 40" above floor (i.e., soap dispensers, towels toilet seat covers, auto- dryers, sanitary napkin dispensers, waste receptacles, Controls and operating mechanisms are operable with one hand and do not require tight grasping, pinching, or twisting of the wrist. The force required to activate controls is 5 lb. max. Coat hooks and shelving are located within appropriate reach ranges (48" max. above floor CUPSSANITRY NAPKINS TOWELS DRYER H. TOWELS & WASTE WASTE 74 " M I N . If medicine cabinets are provided, at least one has a usable shelf no higher than 44" above floor. recommended). than 40" from the floor. A. B. LAVATORIES C. D. E. distance to center of fixture. underneath the lavatory. G. of the lavatory. front of the lavatory I. J. flow). lavatory. to prevent contact. H. F. L. wrist. INTERPRETATIONS: DESIGN FOR RESTAURA N T P L U S , I N C . DRAWN BY JIMMY ZHANG (626) 57 0 - 9 9 7 8 K. encroach into the required knee clearance. The fact that and construction error regarding lavatory must be a min. of 27" high and extend back a min. of 8" from the front edge. Lavatory bowls with excessive depth oftentimes restrict this required clearance even when the top of the bowl is mounted at the max. allowed 34". This situation is of particular importance in Alterations, as many older model lavatories simply cannot provide for both max. mounting height and required knee clearance. It is also important to understand that the drain piping cannot There are no sharp or abrasive elements under Faucets are lever type, electronically activated or approved self closing valves (Min.10 seconds open Faucets are operable with one hand and do not require tight grasping, pinching or twisting of the 5 lb. max. force required to activate controls. Possibly the most common design Min. 30" x 48" clear space is provided in front of Required clear space adjoins or overlaps an accessible route and extends a max. of 19" Lavatories adjacent to a side wall have a min. 18" 34" max. height of rim or counter above floor surface. 29" min. clearance from bottom of apron to the floor. Knee clearance under front lip is a min. of 27" high, 30" wide, and extends a min.of 8" in depth from the Toe clearance under lavatory is a min. of 9" high, 30" wide, and extends a min. of 17" in depth from the front Drain and hot water piping is insulated or configured lavatory that allows forward approach. J CEMENT, MARLITE ETC). SMOOTH, HARD, NONABSORBENT SURFACE (TILE, Fig. 1 6" MAX. TOE CLEARANCE MI N " 8" MIN. KNEE CLEARANCE 17" MIN. 9"29 " M I N . 27 " M I N . 40 " M A X . 34 " M A X . TOILET SEAT COVER DISPENSER. 40 " M A X . H SINGLE OCCUPANCY DISABLED TOILET 1/32"58"-60" OR EQUAL 17" MIN. FOR in width EXIT TACTILE EGRESS SIGN (Address) (Telephone Number) Police Department12 " 12" MAX 19 " M I N . or effort. opposite stop. grouped on 1 level of aparking structure. the side wall or partition measured to the top of a Max 2" high toilet seat. side of toilet area. Fig. 8 All new and relocated electrical receptacle outlets/mounting heights/disabled access: Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles are to be located: 2. outlet box or receptacle housing, and; 4.1 No more than 48-inches, measured from the top of the receptacle outlet box or receptacle housing, to the level of the finished floor or 4.2 No more than 15-inches, measured from the bottom of the receptacle working platform. 48" MIN CLEAR 60 " M I N C L E A R 60" MIN CLEAR MIN 17" TO MAX 18" 1 1/2" MAX.1 1/2" MAX. 34 " T O 3 8 " 12" MIN. T 34 " T O 3 8 " 34 " T O 3 8 " 2" MIN. 4' MAX. 1' MAX.T=TREAD WIDTH *NOTE: EXTERIOR STAIRS ALL TREADS ARE TO HAVE WARNING STRIPES PER SEC. 1123A.5 * * 12" PLUS TREAD WIDTH MIN. CBC 11B-404 ON THE PUSH SIDE 11B-307 PROTRUDING OBJECTS 307.1 GENERAL Protruding objects shall comply with section 11B-307 307.2 Protruding limit. Object with leading edges more than 27 inches(686mm) and not more than 80 inches (2032mm) above the finish floor or ground shall protrude protrude 4 inches (102mm) maximum horizontally into the circulation path. Exception handrails shall be permitted to protude 4 1/2 inches(114mm) maximum. NOTE: THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A LOOP OR " U-SHAPE" HANDLE IMMEDIATELY BELOW THE LATCH. [1115B.3.1,#4.5] THE LATCH SHALL BE FLIP-OVER OR SLIDING STYLE. [1115B.3.1,#4.5] 1.6-2.4 41-61 LC LC LC (a) elevation (enlarged) (b) plan 0.2 5.1 top diameter of 50%-65% of the base diameter base diameter of 0.9-1.4 (23-36 mm) 0.65 min 17 1.6-2.4 41-61LC City of Arcadia 70 SQ. INCHES ACCESSIBILITY 9'-0" MIN.9'-0" MIN. STRIPES AT 36" ON CENTER 18 ' - 0 " M I N . 8'-0" MIN. AT VAN ACCESSIBLE PARKING STALL DOUBLE PARKING STALLS FIGURE 11B-18A PER SEC. 1129B.4 TYP. PAVEMENT SYMBOL SIGN PER SEC. 1129B.4 PROVIDE WHEEL STOP IF SIDEWALK IS 4' IN WIDTH FOR WALK WIDTH 6' OR (WHELL STOP NOT REQ'D GREATER) 24 " 8" 2% MA X . 48" MIN. 48 " M I N . 10% MAX. SIDESLOPE 12" MIN.BORDER GROOVES AT 3/4" O.C. FRONT EDGE OF SIDEWALK 8.33% MAX. CURB RAMPS SLOPE TRUNCATED DOMES PAINTED BULE NOPARKING 4"4" BUILDING WALL VAN RESTROOM RESTROOM 8'-0" MIN. 33 " T O 3 6 " TO FINISH FLOOR C FOR VAN ACCESSIBLE HANDICAPPED RESERVED 80° MIN. FOR FREE STANDING 36" MIN. FOR WALL MOUNTED WALKING SURFACE TO TOP OF MINIMUM FINE $250 1 1/2"Ø GALV. STEEL POST IN CONCRETE FOOTING MTL. COVER PLATE W/ 3 SET SCREWS FINISH GRAD3E CONCRETE FOOTING 3'Ø X 12" GALV. PIPE SLEEVE FILL W/ EPOXY GROUT, TYP. COMPACTED FILL MI N . 6' - 8 " 1' - 6 " 6'-8" MIN. NOTE: WALL SIGN SHALL BE MOUNTED ON THE LATCH SIDE OF SINGLE DOORS; ON THE HINGE SIDE OF THE RIGHT HAND DOOR, IN THE DIRECTION OF TRAVEL, OF DOUBLE DOORS; WITH THE CENTERLINE OF THE SIGN CENTERED ON AN 18"x18" CLEAR FLOOR SPACE IN FRONT OF THE SIGN. THE BOTTOM OF THE BRAILLE CELLS SHALL NOT BE LESS THAN 48" FROM FINISHED FLOOR AND THE TOP OF THE RAISED LETTERS SHALL NOT BE MORE THAN 60" FROM THE FINISHED FLOOR. [CBC 11B-703.4.1, 11B-703.4.2.] C UNISEX UNISEX HANDICAP NOTES & DETAILS 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising SITE PLAN A3 NOTE: 1. NO CHANGE TO EXISTING PARKING SPACE 2. NO ABRUPT CHANGES IN ELEVATION ALONG THE PATH OF TRAVEL SHOWN. THE SLOPE AND CROSS-SLOPE ALONG THE PATH OF TRAVEL SHALL NOT EXCEED 5% AND 2% RESPECTIVELY. INSPECTOR TO VERIFY. 3. NO ALTERATION, OR STRUCTURAL REPAIRS TO ACCESSIBLE PATH OF TRAVEL OF PROJECT UNIT & ITS ELEMENTS. 4. APPROVED BUILDING ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION SHALL BE PROVIDED AND MAINTAINED SO AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY. THE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND, BE ARABIC NUMERALS OR ALPHABET LETTER, AND BE A MINIMUM OF 4 INCHES HIGH WITH A MINIMUM STROKE WIDTH OF 0.5 INCH. FIRE CODE 505.1 SCALE:1 SITE PLAN 1/32" = 1'-0"N 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising A4 EXISTING FLOOR PLAN & REFLECTED CEILING PLAN SCALE:2 EXISTING REFLECTED CEILING PLAN 1/4" = 1'-0" N SCALE:1 EXISTING FLOOR PLAN 1/4" = 1'-0" N 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising AD 4 AD 5 AD 9 AD 10 AD 11 AD 12 FINISH SCHEDULE DOOR SCHEDULE A5 PROPOSED FLOOR PLAN SCALE:1 PROPOSED FLOOR PLAN 1/4" = 1'-0" N SCALE:2 FRONT DESK DESIGN 3/8" = 1'-0" SCALE:3 ENLARGED RESTROOM PLAN (NO CHANGE) 3/8" = 1'-0" NORTH ELEVATION (CUSTOMER SIDE)SOUTH ELEVATION (STAFF SIDE)SECTION 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 A5 2 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising AD 1 AD 6 AD 7/8 AD 2 AD 3 A6 PROPOSED REFLECTED CEILING PLAN & EGRESS PLAN SCALE:2 EGRESS PLAN 1/4" = 1'-0" N SCALE:1 PROPOSED REFLECTED CEILING PLAN 1/4" = 1'-0" N 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising GN1 CALGREEN DATA 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising GN2 CALGREEN DATA 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising GN3 CALGREEN DATA 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007 STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising TYP. GRAB BAR DETAIL 119 SUSPEND LIGHT & CEILING SUPPORTS 1 T-BAR CEILING SUPPORT DETAIL 5 64 SUSPEND LIGHT FIXTURESUSPEND LIGHT & CEILING SUPPORTS THRESHOLD/ FLOOR LEVEL 7 2 8TYPICAL WALL SECTION ( METAL FRAMING) 12 TYPICAL DRYWALL CORNER DETAIL 10 TYPICAL HOLLOW METAL JAMB CONNECTION DETAIL INTERIOR PARTITION & SUSPENDED CEILING 3 PENETRATION DETAIL AD STAMP 229 S. MISSION DR SAN GABRIEL, CA 91776 EMAIL: INFO@YWRISING.COM TEL: 626.542.5946 FAX: 888.847.3831 YW RISING DESIGN & DEVELOPMENT Engineer OWNER PROJECT SHEET TITLE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF YWR ARCHITECTS AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THEDESIGNER. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BEVERIFY BY THE CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH AND/OR BEGINNING ANY WORK. THE CONTRACTOR SHALL COORDINATE ALL STRUCTURAL WORK WITH THE ARCHITECTURAL, MECHANICAL AND ANY OTHERRELATED DRAWINGS, AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING ANY/OR BEGINNING ANY WORK. YW Design & Development A Design Built Company Rising ARCHITECTURAL DETAILS 1-STORY MEDICAL OFFICE TENANT IMPROVEMENT 1238 S GOLDEN W AVE, ARCADIA,CA 91007                                                                                                                                                                                                                                         PIPE MATERIALS SERVICES LOCATION MATERIAL JOINING METHOD REMARKS DOMESTIC COLD & HOT WATER UNDERGROUND RIGID COPPER( TYPE K)BRAZED NOT TO EXCEED 20 OF I PERCENT JOINT FITTINGS. SHOULD STREET PRESSURE EXCEED 80 PSI, A PRESSURE REDUCING VALVE ASSEMBLY SHALL BE INSTALLED. NO JOINTS SHALL BE ALLOWED UNDER BUILDING SLAB. GATE VALVES SHALL BE BRONZE WITH ENDS TO SUITE PIPE, NONRISING STEM FOR 150 PSI WORKING PRESSURE. ABOVE UNDERGROUND RIGID COPPER( TYPE L)SOLDERED SANITARY WASTE SEWER UNDERGROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS ABOVE GROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS SANITARY WASTE VENT ABOVE GROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS LOW PRESSURE GAS UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED PROVEIDE APPROVED GAS PRESSUSRE REGULATORS. NATURAL GAS RIGHT AND LEFT HAND NIPPLES AND COUPLINGS SHALL BE NEW BLACK IRON, UNIONS SHALL NOT BE USED EXCEPT AT UNITS AND VAVLES. ABOVE UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY PLUMBING ABBREVIATIONSPLUMBING LEGENDMEP COMPONENT ANCHORAGE NOTE PIPING SYSTEM BRACING NOTE GENERAL NOTES DOMESTIC WATER PIPING SIZING DOMESTIC WATER CALCULATION FIXTURE CONNECTION SCHEDULE (BRANCH SIZES) MISC. EQUIPMENT SCHEDULE REVISIONS J S E N G I N E E R I N G , I N C . STAMP P1 12 3 8 S . G O L D E N W E S T A V E . , A R C A D I A , C A . 9 1 0 0 7 TE N A N T I M P R O V E M E N T - M E D I C A L C E N T E R  LEGEND FLOOR PLAN (HOT & COLD) 1/4"=1'-0" FLOOR PLAN (WASTE & VENT) 1/4"=1'-0" REVISIONS J S E N G I N E E R I N G , I N C . STAMP P2 12 3 8 S . G O L D E N W E S T A V E . , A R C A D I A , C A . 9 1 0 0 7 TE N A N T I M P R O V E M E N T - M E D I C A L C E N T E R  1 AC ITEM MECHANICAL EQUIPMENT SCHEDULE REVISIONS J S E N G I N E E R I N G , I N C . STAMP M1 12 3 8 S . G O L D E N W E S T A V E . , A R C A D I A , C A . 9 1 0 0 7 TE N A N T I M P R O V E M E N T - M E D I C A L C E N T E R  CEILING PLAN 1/4"=1'-0" ROOF PLAN 1/4"=1'-0" FLOOR PLAN 1/4"=1'-0" REVISIONS J S E N G I N E E R I N G , I N C . STAMP M2 12 3 8 S . G O L D E N W E S T A V E . , A R C A D I A , C A . 9 1 0 0 7 TE N A N T I M P R O V E M E N T - M E D I C A L C E N T E R                                                                                                            