Loading...
HomeMy WebLinkAbout55 E Foothill Blvd - 2024 - ADA ParkingAlley Public Sidewalk East Foothill Blvd 55 E. Foothill N O P A R K I N G AlleyAlley 30 ° 18' TYP 9 ' T Y P N O P A R K I N G ±10'-1" 4' 69 ' - 4 12" 8' 6'- 8 " 4' 1 8 ' M I N F U L L R E Q U I R E D L E N G T H O F P A R K I N G S P A C E 12' MIN 3 6 " T Y P 5' MIN NO PARK I N G 3' 70 SQ. INCH ACCESSIBILITY SIGN. BOTTOM OF SIGN MOUNTED ON BUILDING 60" MIN. AFF.. SIGN INCLUDES "MINIMUM FINE $250" AND "VAN ACCESSIBLE" SIGN. SEE PER SEC. 11B-502.6 17"x22" SIGN STATING "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT: ARCADIA PD OR BY TELEPHONING (626) 571-5158" ACCESS AISLE W/ 4" BLUE BORDER W/ "NO PARKING" IN 12" WHITE LETTERING DIAGONAL STRIPING IN BLUE OR WHITE OPTIONAL EXTENSION OF ACCESS AISLE MARKING TO ALIGN W/ ADJACENT STALLS 3' 3' INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH CBC 11B-502.6.4 2% MAX SLOPE TO ALLEY SITE PLAN, + ACCESSIBLE UPGRADES A.1 Scale: NTS ENLARGED ACCESSIBLE PARKING STALL PROJECT SUMMARY 1 CONSTRUCTION TYPE OCCUPANCY GROUP USE GROUP B FLORIST TYPE V-B # OF STORIES: DATE BUILDING ERECTED: BUILDING SQUARE FOOTAGE: HANDICAP PARKING AVAILABLE FULLY SPRINKLERED FACILITY YES NO 1952 1,474 S.F SCOPE OF WORK PER INSPECTION NOTICE, OBTAIN PLANNING AND BUILDING APPROVAL FOR NEW CONCRETE PARKING LOT WITH RESTRIPING TO ADD ACCESSIBLE PARKING PER CBC 11B-502. TOTAL NUMBER OF PARKING SPACES REDUCED FROM 5 TO 4 SPACES. VICINITY MAP 55 E. FOOTHILL BLVD. ARCADIA, CA SITE PARKING SQUARE FOOTAGE:2,080 S.F PROJECT DIRECTORY ARCHITECT DANETTE MUNIR 227 SOUTH MADISON AVENUE SUITE 103 PASADENA, CA 91101 P 626.201.3082 E dlmunir@gmail.com BUILDING OWNERS TIM GRIESINGER 1525 SUNRISE CIRCLE CARLSBAD, CA 92008 P 760.518.3819 Tim.Griesinger@gmail.com 1SCALE: 1/16"= 1'-0"3SCALE: 1/8"= 1'-0"5SCALE: 1/8"= 1'-0" 2 LOCATION OF (E) SEWER COVER PREVIOUS PARKING PLAN SITE PLAN - ACCESSIBLE PATH OF TRAVELNEW AS-BUILT PARKING PLAN NOTE: FOR REFERENCE ONLY. PLAN AS SHOWN IN SATELLITE IMAGE FROM 2023. AS-BUILTS OF PARKING PLAN NOT AVAILABLE. 5- 2- ACCESSIBLE PARKING AND ACCESS AISLE SLOPED AS MUCH AS ALLOWED (1:48 MAX) TO ALLEY FOR DRAINAGE. NEW CONCRETE SURFACE FOLLOWS EXISTING LEVEL AT REMAINDER OF LOT, SLOPED TO ALLEY. ONLY AREA AROUND THE NEW ACCESSIBLE STALL AND PATH OF TRAVEL RE-LEVELED AS INDICATED. 1. ACCESSIBLE PATH OF TRAVEL IS DEFINED AS "A CONTINUOUS UNOBSTRUCTED PATH CONNECTING ACCESSIBLE ELEMENTS THAT CAN BE NEGOTIATED BY A PERSON WITH A DISABILITY USING A WHEELCHAIR AND THAT IS ALSO SAFE FOR AND USABLE BY PERSONS WITH OTHER DISABILITIES, AND THAT IS CONSISTENT WITH THE DEFINITION OF "PATH OF TRAVEL". (11B-206) 2. SITE DEVELOPMENT AND GRADING SHALL BE DESIGNED TO PROVIDE ACCESS TO ALL ENTRANCES AND EXTERIOR GROUND FLOOR EXITS, AND ACCESS TO NORMAL PATHS OF TRAVEL, AND WHERE NECESSARY TO PROVIDE ACCESS, SHALL INCORPORATE PEDESTRIAN, CURB RAMPS, ETC. (11B-206.2.) 3. THE ACCESSIBLE ROUTE OF TRAVEL SHALL BE THE MOST PRACTICAL DIRECT OUTE BETWEEN ACCESSIBLE BUILDING ENTRANCES, ACCESSIBLE SITE FACILITIES, AND THE ACCESSIBLE ENTRANCE TO THE SITE. IF ACCESS IS PROVIDED FOR PEDESTRIANS FROM A PEDESTRIAN TUNNEL OR ELEVATED WALKWAY, ENTRANCES TO THE BUILDING FROM EACH TUNNEL OR WALKWAY MUST BE ACCESSIBLE. (11B.2) 4. NO ABRUPT CHANGES IN ELEVATION ALONG THE ACCESSIBLE PATH OF TRAVEL SHOWN. 5. THE SLOPE ALONG THE POT SHALL NOT EXCEED 5% (1:20) IN DIRECTION OF TRAVEL. 6. THE SLOPE AT AN ACCESSIBLE RAMP SHALL NOT EXCEED 8% (1:12). 6. THE CROSS-SLOPE ALONG THE POT SHALL NOT EXCEED 2% (1:48). 7. LANDINGS SUBJECT TO WET CONDITIONS SHALL BE INSTALLED TO PREVENT THE ACCUMULATION OF WATER, CBC 11B-405.10. ACCESSIBLE POT NOTESACCESSIBLE PARKING NOTES 1. WHERE PARKING SPACES ARE PROVIDED, PARKING SPACES SHALL BE PROVIDED IN ACCORDANCE WITH 11B-208. 2. FOR EVERY SIX OR FRACTION OF SIX PARKING SPACES REQUIRED, AT LEAST ONE SHALL BE A VAN PARKING SPACE COMPLYING WITH 11B-502. 3. ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE FROM PARKING TO AN ACCESSIBLE ENTRANCE. 4. ACCESSIBLE PARKING SPACES SHALL BE 18 FEET (217 INCHES) LONG MINIMUM . CAR PARKING SPACES SHALL BE 9 FEET (108 INCHES) WIDE MINIMUM . VAN SPACES SHALL BE 12 FEET (144 INCHES) WIDE MINIMUM 5. ACCESS AISLES PERMITTED ON EITHER SIDE OF THE CAR PARKING SPACE. AISLES FOR VAN SPACES SHALL BE LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACE. 6. ACCESSIBLE PARKING SPACES, ACCESS AISLES AND VEHICULAR ROUTES SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE OF 8 FEET, 2 INCHES (98 INCHES) MINIMUM. 7. ACCESSIBLE PARKING AND ACCESS AISLES SHALL BE DESIGNED SO THAT PERSONS USING THEM ARE NOT REQURIED TO TRAVEL BEHIND PARKING SPACES OTHER THAN TO PASS BEHIND THE PARKING SPACE IN WHICH THEY ARE PARKED. 8. A CURB OR WHEEL STOP SHALL BE PROVIDED IF REQUIRED TO PREVENT ENCROACHMENT OF VEHICLES OVER THE REQURIED CLEAR WIDTH OF ADJACENT ACCESSIBLE ROUTES. Sheet Seal DM Project Sheet Revisions Date DescriptionNo. Danette Munir architecture | interiors 227 South Madison Avenue, Suite 103 Pasadena, California 91101 dlmunir@gmail.com | p: 626.201.3082 Set Issue Dates Date Issue for PA R K I N G R E S U R F A C I N G AN D R E S T R I P I N G 55 E . F O O T H I L L B L V D . AR C A D I A , C A 9 1 0 0 6 24-034 04.17.24 OWNER REVIEW 04.19.24 PLAN REVIEW LIC E N S E D ARCHIT E C T S T A TE OF CA L I F O R NIA DANETTE MUNIR C35911 RENEWAL DATE 05/31/25 LOCATION OF (E) SEWER COVER (E) WATER SHUTOFF SCALE: 3/16"= 1'-0" INDICATES PATH OF TRAVEL FROM ACCESSIBLE PARKING, 1:20 MAX SLOPE IN DIRECTION OF TRAVEL, 1:48 MAX CROSS SLOPE, U.O.N. EXISTING LOT SLOPED TO ALLEY FOR DRAINAGE EDGE OF NEW 4" CURB PAINTED YELLOW (E) CONCRETE PADS AT DOORS TO REMAINRA M P U P 1: 2 0 S L O P E INDICATES PATH OF TRAVEL FROM PUBLIC RIGHT OF WAY CONTRACTOR STEVE DICKERMAN S & S GRADING AND PAVING, INC. O 951.340.9590 C 951.255.6977 E s-grading@sbcglobal.net