Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
211 E Foothill Blvd - 2024 - Ralphs refrigeration equipment
CLIENT ELECTRICAL ENGINEER REFRIGERATION RALPHS GROCERY COMPANY PACIFIC ENGINEERS GROUP HUSSMANN 1100 W. ARTESIA BLVD.,1106 W. MAGNOLIA BLVD. STE A 13770 RAMONA AVE. COMPTON, CA 90220 BURBANK, CA 91506 CHINO, CA 91710 ATTN: DANIEL RODRIGUEZ ATTN: MEL FAJARDO ATTN: JULIO SOTO TEL.: (310) 900-3215 TEL.: (818) 842-7285 TEL.: (909) 548-2415 EMAIL: daniel.rodriguez@kroger.com EMAIL:melfajardo@pacificeng.net EMAIL: julio.soto@hussmann.com PROJECT DESCRIPTION VICINITY MAP MARKET # 041 REFRIGERATION EQUIP. REMODEL 211 E. FOOTHILL BLVD. ARCADIA, CA 91006 A COMMERCIAL PROJECT FOR: RALPHS GROCERY COMPANY PROJECT MANAGER: DANIEL RODRIGUEZ 1100 WEST ARTESIA BOULEVARD COMPTON, CA TEL: (310) 900-3215 DIRECTORY N SITE E HUNTINGTON DR. E DUARTE R D . E FOOTHILL BLVD. N S A N T A A N I T A A V E . N 2 N D A V E . N 5 T H A V E . S M A Y F L O W E R A V E . G0.1 COVER SHEET REPLACEMENT OF REFRIGERATION RACKS IN MACHINE ROOM. INDEX OF DRAWINGS SEQ . NO. SHT. NO.DESCRIPTION BID ISSUE ADD ADD CCD CCD GENERAL 01 G0.1 COVER SHEET REFRIGERATION EQUIPMENT (FOR REFERENCE ONLY) 02 RM.1 (E) FIXTURE FLOOR PLAN 03 RM.2A REFRIGERATION OEM SCHEDULE 04 RM.2B REFRIGERATION OEM SCHEDULE 05 RM.2C REFRIGERATION OEM DANFOSS ASSIGN. 06 RM.3 WIRING SCHEMATIC 07 RM.4 (E) MECH. RM. NEW REF. OEM UNITS & DET. 08 RM.4A SEISMIC CALCS. FOR REF. OEM UNITS 09 RM.4B REF. OEM SEISMIC ANCHORAGE CALCS. 10 RM.5 REFRIGERATION INSTALLATION DETAILS ELECTRICAL 11 E1.0 ELECTRICAL SYMBOLS & GEN. NOTES. 12 E2.0 OVERALL ELECTRICAL PLAN 13 E3.0 ENLARGED POWER PLAN 14 E4.0 SINGLE LINE DIAGRAM 15 E4.1 PANEL SCHEDULE 16 E5.0 WIRING SCHEMATIC DIAGRAM 1 2 1 2 11 0 0 W E S T A R T E S I A B O U L E V A R D CO M P T O N , C A L I F O R N I A 9 0 2 2 0 RA L P H S G R O C E R Y C O . SEE SHEET RM.4 FOR MORE DETAILS. · · · · · · · · · · · SALES PERSON PROJECT MANAGER REVISIONS RM.1 RA L P H S # 0 4 1 AR C A D I A , C A . MI N O R C A P I T A L 21 1 E . F O O T H I L L B L V D . , SCOTT THOPMSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 (E) FIXTURE FLOOR PLAN FLOOR PLAN BASED ON RALPHS R1.1: REV- _____________, DATE __________0 4/26/2023 *****************ATTENTION***************** IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DO ALL DEMOLITION WORK FOR THIS PROJECT PER RALPHS/FOOD-4-LESS SPECIFICATIONS AND GUIDELINES. GENERAL NOTES EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS TO APPLICABLE EACH TRADE. M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B E RKHEIM E R ECHA N I C A LS TATEOF CA L I F AINR M O SALES PERSON PROJECT MANAGER REVISIONS RM.2A RA L P H S # 0 4 1 AR C A D I A , C A MI N O R C A P I T A L 21 1 E F O O T H I L L B L V D . , SCOTT THOPMSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 REFRIGERATION OEM SCHEDULE EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS APPLICABLE TO EACH TRADE. Customer Kroger Appl Eng Espinosa R.Quote 718488 Sales Order Order Lineup 1 Store RA-041 Rev Date 07/25/2023 Quote Rev R3 Order Rev Order Position 1 Location Arcadia, CA USA Draw Ref RA-041 R6.1 BPCS Item 1111 Physical Information Rack Discharge Component Information Rack Liquid Component Information Electrical Information Rack Model TZ600-053-UL-4-DSS2A-A Discharge Header Size 1 3/8 Condenser Return Connection Size 1 1/8 208/60/3 460/60/3 575/60/3 Rack Refrigerant R448A Oil Separator Model S-5390 Drop Leg Shut Off Valve Model **A-17465 Rack MCA 0.0 81.1 0.0 Rack Dimensions (D x H x W )30.5 x 78.6 x 45 Discharge Check Valve Model A17941 Drop Leg Check Valve Model **A17940 Rack MOPD 0 90 0 Est. Rack Lift Weight (lb)1,600 Discharge Pressure Regulator Model None Drop Leg Reg Valve Model None Condenser MCA (not from rack) Est. Rack Operating Weight (lb)Hot water HR Valve Model ^^12D11B Liquid Filter/Drier Shell Model **C-969-G Condenser MOPD (not from rack) Rack Vibration Isolation None Hot Water HR Supply Connection Size 1 3/8 Liquid Filter/Drier Core Model ^^(2) RCW-48 Gold Receiver Style V Hot Water HR Return Connection Size 1 3/8 Liquid Supply Sightglass Model **A18120 Rack Control Voltage 208 Receiver Dimensions (DxL)^^12.75 x 67 Comfort HR Valve Model ^^12D11B Liquid Control Valve Model None Condenser Control Voltage 208 Receiver Insulation None Comfort HR Supply Connection Size 1 3/8 Liquid Shut Off Valve Model **A-17465 Receiver Pump-Down * (lb)323 Comfort HR Return Connection Size 1 3/8 Condenser to Rack Line Size 1 1/8 Compressor Controller Danfoss AK2-SM-880A Ref/Hvac/Lght * % Full @ 90°F Liquid 90%Split Condenser Valve Model None Defrost Controller Danfoss AK2-SM-880A Ref/Hvac/Lght Outdoor Design Dry Bulb °F +100.0 Condenser Supply Connection Size 1 3/8 Condenser Controller Danfoss AK2-SM-880A Ref/Hvac/Lght Outdoor Design Wet Bulb °F +73.0 Rack to Condenser Line Size 1 3/8 Max. Indoor Design Dry Bulb°F +75.0 Max. Indoor design HR%55% Condenser Information Model Fan Style FPI TD Net Weight Each Ship Weight Each Fan Qty Each Sections Wide Size Each FLA Each MCA Each MOPD Each Power Each (Watt) THR/TD Alt Corr THR/TD Relay Board in CBox Rack to Condenser Line Size Condenser to Rack Line Size Motor RPM Water Inlet Temp Water GPM Min Water GPM Max Water GPM Req'd Water Press Drop (psi) JC 200 Danfoss AK2-XM 204A Unit 1 DSS A 308,600 Unit 2 DSS B 927,100 Unit 3 DSS C 634,500 Suction Group Performance Information Suction Group Suction Temp Cond Temp Target Liquid Temp Lvg Evap Load (Btuh) Comp Gross (Btuh) Natural Subcool (Btuh) Mech Subcool (Btuh) Suction Line (Btuh)NRE (Btuh) Excess Btuh (%) Comp Power (Watt) Comp THR (Btuh) THR Factor HR Avail (Btuh) Comp HP Total RLA Total Suction Accumulator Suction Filter Shell CCH Amp HCF Amp Subcooler Model Subcooler EPR SC TXV 1 SC TXV 2 SC EEV SC EEV Solenoid SC EEV Solenoid Coil A1 -25.0 +100.0 +50.0 158,100 145,642 0 32,367 0 178,009 12.6%33,144 285,441 1.96 142,721 52 1/2 75.7 ^^BTAS-521SV 0.00 0.00 SC 3 Port-3-7 None None Sporlan SER-C E9S240 wo Coil MKC-2 208 Total +100.0 158,100 145,642 0 32,367 0 178,009 12.6%33,144 285,441 1.96 142,721 52 1/2 75.7 0.00 0.00 Compressor Information Comp Location Number Suction Group Model HP NRE Watt THR RLA LRA Contactor Circuit Breaker Wire Size Unloader VFD Suction Accumulator Suction Shell Discharge Part CCH Amp HCF Amp Top 1 A1 ZFD25KVE-TFD-262 7 1/2 26,079 4,751 41,479 10.6 99.0 C25DRF330B PDG13F0020TFFJ 14 Digital None None None 0.00 None Top 2 A1 ZF28KVE-TFD-262 9 30,386 5,679 48,792 13.0 121.4 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Top 3 A1 ZF28KVE-TFD-262 9 30,386 5,679 48,792 13.0 121.4 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Bottom 4 A1 ZF28KVE-TFD-262 9 30,386 5,679 48,792 13.0 121.4 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Bottom 5 A1 ZF28KVE-TFD-262 9 30,386 5,679 48,792 13.0 121.4 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Bottom 6 A1 ZF28KVE-TFD-262 9 30,386 5,679 48,792 13.0 121.4 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Circuit Information RH 1 Cir #Store Circ ID Model Size Description Type Comment HX Model TXV Model Load Evap Temp Disc Air Temp Liquid Valve Suction Valve Hot Gas Valve Def Type Def Volt Def Breaker Def Ph Fan Volt Fan Amp Fan Phase Fan Watt Canopy Amp Nose Amp Shelf Amp Light Watt A/S Amp A/S Watt Run Rise Riser Size Suction Size Liquid Size Temp Sensor Qty RH 1 Main Pipes to DSS RH 1 Unknown Main Pipes to DSS 158,100 -25 A17464 AC17869 None Electric 2 5/8 2 5/8 7/8 1 11C Unknown 30'-3"x14'-7"x9'Unknown (2) LECH-174 Grocery Freezer 31,100 -22 AQ17861 A17468 None Electric 208 40A 3 125 20 1 5/8 2 1/8 1/2 3 2 12K Unknown 5,4 Unknown RLN LT Grocery Reach-In 8,600 -11 AQ17860 A17464 None Electric 208 50A 3 125 20 7/8 7/8 3/8 2 3 Combo 11A,B,D Unknown Unknown Combo 48,100 -19 AQ17861 AC17869 None Electric 125 20 2 1/8 2 5/8 1/2 11A Unknown 2,3,3,3,3,5 Unknown RLN LT Grocery Reach-In -11 Existing Existing None Electric 208 40A, 50A 3 125 20 1 1/8 1 3/8 3/8 4 11B Unknown 4,5,5,5 Unknown RLN LT Grocery Reach-In -19 Existing Existing None Electric 208 40A, 50A 3 125 20 1 3/8 1 5/8 3/8 3 11D Unknown 5,5 Unknown RLN LT Grocery Reach-In -11 Existing Existing None Electric 208 50A 3 125 20 7/8 1 1/8 3/8 2 4 Combo 12G, H Unknown Unknown Combo 44,800 -11 AQ17861 A17468 None Electric 125 20 2 1/8 2 1/8 1/2 12G Unknown 3,3,4,5,5,5 Unknown RLN LT Grocery Reach-In -11 Existing Existing None Electric 208 60A, 60A 3 125 20 1 3/8 1 5/8 1/2 3 12H Unknown 2,2,3,5,5,5 Unknown RLN LT Grocery Reach-In -11 Existing Existing None Electric 208 60A, 60A 3 125 20 1 3/8 1 3/8 3/8 4 5 12D Unknown 12'-3"x10'-3"x9'Unknown LEL0130 Bakery Freezer 12,100 -22 AQ17860 A17466 None Electric 208 20A 3 125 20 1 1/8 1 3/8 3/8 2 6 12J Unknown 2,2 Unknown RLN LT Ice Cream 4,300 -19 AQ17860 A17464 None Electric 208 50A 3 125 20 5/8 7/8 3/8 2 7 12X Unknown 24'Unknown FN-12 9,100 -20 AQ17860 A17465 None Electric 125 20 7/8 1 1/8 3/8 2 8 Spare Spare Spare Spare Spare AQ17862 A17467 None None 125 20 1 3/8 1 5/8 5/8 1 (All A and B defrosts located in remote vertical control box 1) Remote Header 1 9 - Crkts, 90" inches Long 20.687" Wide x 74.5 High Max Dry Weight 951 LBS 208v/3 12.0 MCA 15 MOPD Remote header Power from Store Panel Revisions Additional Notes Note Description Date By VERIFY DEFROST AMPS AND PHASE AT ORDER ENTRY 2 Changed remote header RH 1 to 114"07/17/23 RME Suction Headers with standard dip Tubes 3 Changed remote header RH 1 to 90"07/25/23 RME valves located on Remote Header. And loose for sub loops New Remote Header W/Receiver & Defrost panel Remote Header Power from Building Rlectrical Panel Check Actual Defrost Loads Per Circuit ^^Indicated Ship Loose Components “Refrigeration equipment supplier (OEM) to size and provide loose parts.” **Indicates RHD Components for Non-Circuit Information. All Components in Circuit Information are for RHD Only Customer Kroger Appl Eng Espinosa R.Quote 718488 Sales Order Order Lineup 1 Store RA-041 Rev Date 07/25/2023 Quote Rev R3 Order Rev Order Position 1 Location Arcadia, CA USA Draw Ref RA-041 R6.1 BPCS Item 2222 Physical Information Rack Discharge Component Information Rack Liquid Component Information Electrical Information Rack Model TZ420-075-UC-4-DBVX-B Discharge Header Size 2 1/8 Condenser Return Connection Size 2 1/8 208/60/3 460/60/3 575/60/3 Rack Refrigerant R448A Oil Separator Model S-5302 Drop Leg Shut Off Valve Model **A-17468 Rack MCA 0.0 130.6 0.0 Rack Dimensions (D x H x W )78 L x 78H x 29W Discharge Check Valve Model A17943 Drop Leg Check Valve Model **A17943 Rack MOPD 0 150 0 Est. Rack Lift Weight (lb)3,200 Discharge Pressure Regulator Model None Drop Leg Reg Valve Model None Condenser MCA (not from rack) Est. Rack Operating Weight (lb)Hot water HR Valve Model None Liquid Filter/Drier Shell Model **C-14413-G Condenser MOPD (not from rack) Rack Vibration Isolation None Hot Water HR Supply Connection Size None Liquid Filter/Drier Core Model ^^(3) RCW-48 Gold Receiver Style V Hot Water HR Return Connection Size None Liquid Supply Sightglass Model **A18122 Rack Control Voltage 208 Receiver Dimensions (DxL)^^12.75 x 67 Comfort HR Valve Model ^^16D17B Liquid Control Valve Model None Condenser Control Voltage 208 Receiver Insulation None Comfort HR Supply Connection Size 2 1/8 Liquid Shut Off Valve Model **A-17467 Receiver Pump-Down * (lb)323 Comfort HR Return Connection Size 2 1/8 Condenser to Rack Line Size 2 1/8 Compressor Controller See Controller DSS A * % Full @ 90°F Liquid 90%Split Condenser Valve Model None Defrost Controller Outdoor Design Dry Bulb °F +100.0 Condenser Supply Connection Size 2 1/8 Condenser Controller Outdoor Design Wet Bulb °F +73.0 Rack to Condenser Line Size 2 1/8 Max. Indoor Design Dry Bulb°F +75.0 Max. Indoor design HR%55% Condenser Information Model Fan Style FPI TD Net Weight Each Ship Weight Each Fan Qty Each Sections Wide Size Each FLA Each MCA Each MOPD Each Power Each (Watt) THR/TD Alt Corr THR/TD Relay Board in CBox Rack to Condenser Line Size Condenser to Rack Line Size Motor RPM Water Inlet Temp Water GPM Min Water GPM Max Water GPM Req'd Water Press Drop (psi) See Condenser DSS A Suction Group Performance Information Suction Group Suction Temp Cond Temp Target Liquid Temp Lvg Evap Load (Btuh) Comp Gross (Btuh) Natural Subcool (Btuh) Mech Subcool (Btuh) Suction Line (Btuh)NRE (Btuh) Excess Btuh (%) Comp Power (Watt) Comp THR (Btuh) THR Factor HR Avail (Btuh) Comp HP Total RLA Total Suction Accumulator Suction Filter Shell CCH Amp HCF Amp Subcooler Model Subcooler EPR SC TXV 1 SC TXV 2 SC EEV SC EEV Solenoid SC EEV Solenoid Coil B1 +16.0 +95.0 +75.0 448,800 381,501 0 32,596 0 414,097 -7.7%45,864 530,163 1.39 265,081 52 82.6 ^^BTAS-525SV 0.00 0.00 SC 3 Port-3-7 None None Sporlan SER-C E9S240 wo Coil MKC-2 208 B2 +18.0 +95.0 +75.0 172,900 191,140 0 15,447 0 206,587 19.5%17,444 247,683 1.30 123,841 23 40.4 ^^BTAS-417SV 0.00 0.00 SC 3 Port-3-7 None None Sporlan SER-C E9S240 wo Coil MKC-2 208 Total +95.0 621,700 572,641 0 48,044 0 620,684 -0.2%63,308 777,846 1.36 388,923 75 122.9 0.00 0.00 Compressor Information Comp Location Number Suction Group Model HP NRE Watt THR RLA LRA Contactor Circuit Breaker Wire Size Unloader VFD Suction Accumulator Suction Shell Discharge Part CCH Amp HCF Amp Top 1 B1 ZFD41K5E-TFD-260 13 103,525 11,466 132,541 20.6 125.0 C25DRF330B PDG13F0045TFFJ 10 Digital None None None 0.00 None Top 2 B1 ZF41K5E-TFD-260 13 103,524 11,466 132,540 20.6 125.0 C25DRF330B PDG13F0045TFFJ 10 None None None None 0.00 None Top 3 B1 ZF41K5E-TFD-260 13 103,524 11,466 132,540 20.6 125.0 C25DRF330B PDG13F0045TFFJ 10 None None None None 0.00 None Bottom 4 B1 ZF41K5E-TFD-260 13 103,524 11,466 132,540 20.6 125.0 C25DRF330B PDG13F0045TFFJ 10 None None None None 0.00 None Bottom 5 B2 ZBD76K5E-TFD-260 10 93,004 7,953 111,938 18.6 125.0 C25DRF330B PDG13F0035TFFJ 10 Digital None None None 0.00 None Bottom 6 B2 ZB95K5E-TFD-260 13 113,583 9,491 135,745 21.8 150.0 C25DRF330B PDG13F0045TFFJ 10 None None None None 0.00 None Circuit Information RH 2B Cir #Store Circ ID Model Size Description Type Comment HX Model TXV Model Load Evap Temp Disc Air Temp Liquid Valve Suction Valve Hot Gas Valve Def Type Def Volt Def Amp Def Ph Fan Volt Fan Amp Fan Phase Fan Watt Canopy Amp Nose Amp Shelf Amp Light Watt A/S Amp A/S Watt Run Rise Riser Size Suction Size Liquid Size Temp Sensor Qty RH 2B Main Pipes to DSS RH 2B Unknown Main Pipes to DSS 448,800 +18 A17464 AC17869 None Electric 2 5/8 2 5/8 7/8 1 22H Unknown 575 sq ft Unknown Meat Cooler 34,300 +20 AQ17861 A17466 None Electric 208 50A 3 125 20 1 1/8 1 3/8 1/2 2 2 Combo 22M Unknown Unknown Combo 52,200 +18 AQ17861 A17467 None Off Cycle 125 20 1 3/8 1 5/8 1/2 22M1 Unknown 11'-1"x12'x9', 20ft Unknown Deli Cooler, SS Deli +18 Existing Existing None Off Cycle 125 20 1 1/8 1 3/8 1/2 2 22M2 Unknown 8'Unknown PT-8R-RRS SS Deli +20 Existing Existing None Off Cycle 125 20 1/2 7/8 3/8 1 22M3 Unknown 10'Unknown PTD Hot/Cold Deli +18 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 1 3 22L Unknown 691 sq ft Unknown Produce Cooler 38,400 +24 AQ17861 A17466 None Off Cycle 125 20 1 1/8 1 3/8 1/2 1 4 Combo 21H Unknown Unknown Combo 22,800 +20 AQ17860 A17465 None Off Cycle 125 20 7/8 1 1/8 3/8 21HA Unknown 12',12',8',8'Unknown D5XLEP MD Beverage +32 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 2 21HB Unknown 12'Unknown R3-HVM-12 SS Meat +20 Existing Existing None Off Cycle 125 20 3/8 1/2 3/8 1 21HC Unknown 12'Unknown R3-HVM-12 SS Meat +20 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 1 5 Combo J Unknown Unknown 14,400 +20 AQ17860 A17464 None Off Cycle 125 20 7/8 7/8 3/8 21J Unknown 12',12'12'Unknown D5XLEP MD Beverage +32 Existing Existing None Off Cycle 125 20 1/2 7/8 3/8 2 21JC Unknown 4'Unknown PT-4R-RRS SS Sushi +20 Existing Existing None Off Cycle 125 20 1/2 5/8 3/8 1 6 22N Unknown 12',12',8',8'Unknown D5XLEP ME Produce 10,800 +32 AQ17860 A17464 None Off Cycle 125 20 5/8 7/8 3/8 2 7 21E Unknown 12'Unknown O4ID MD Wide Island w/ Ends 23,400 +22 AQ17860 A17465 None Off Cycle 125 20 7/8 1 1/8 3/8 1 8 2C6 Unknown 559 sq ft Unknown Deli Produce Prep 19,600 +35 AQ17860 ORIT6-7 / EVR15-7 None Off Cycle 125 20 7/8 7/8 3/8 1 9 RH2A Unknown Unknown Remote Header 2A 232,900 +20 A17464 AC17869 None Off Cycle 125 20 2 5/8 2 5/8 7/8 1 10 Spare Spare Spare Spare Spare AQ17862 A17467 None None 125 20 1 3/8 1 5/8 5/8 1 RH 2B-R Main Pipes to DSS RH 2B Unknown Main Pipes to DSS 172,900 +20 A17464 AC17869 None None 2 5/8 2 5/8 7/8 11 Combo 23T Unknown Unknown Combo 56,500 +35 AQ17862 A17466 None Off Cycle 125 20 1 1/8 1 3/8 5/8 Comp Room AC Unknown Unknown Comp Room AC +35 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 1 District Manager AC Unknown Unknown District Manager AC +35 Existing Existing None Off Cycle 125 20 1/2 5/8 3/8 1 Store manager AC Unknown Unknown Store manager AC +35 Existing Existing None Off Cycle 125 20 1/2 5/8 3/8 1 Bookeeper AC Unknown Unknown Bookeeper AC +35 Existing Existing None Off Cycle 125 20 1/2 5/8 3/8 1 Break Room AC Unknown Unknown Break Room AC +35 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 1 12 Combo 39 Unknown Unknown Combo 116,400 +20 A17464 A17468 None Off Cycle 125 20 2 1/8 2 1/8 7/8 39A3A Unknown 12'Unknown R3-HVF SS Seafood +20 Existing Existing None Off Cycle 125 20 3/8 1/2 3/8 1 39A3B Unknown 12'Unknown R3-HVF SS Seafood +20 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 1 39A2 Unknown 4'Unknown O5DMM MD Produce +28 Existing Existing None Off Cycle 125 20 1/2 5/8 3/8 1 39B1 Unknown 4',4', 90° Wedge Unknown FT-4R Floral, FT90 Floral Wedge +22 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 2 39B2 Unknown 8'Unknown FL5NX MD Floral +28 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 1 39C Unknown 12',12',12',12', 8'Unknown O5DMM MD Produce +28 Existing Existing None Off Cycle 125 20 1 3/8 1 5/8 5/8 3 13 Spare Spare Spare Spare Spare AQ17862 A17467 None None 125 20 1 3/8 1 5/8 5/8 1 (All A and B defrosts located in remote vertical control box 1) Remote Header 2B 13 - Crkts, 114 inches Long 20.687" Wide x 74.5 High Max Dry Weight 1031 LBS 208v/3 12.0 MCA 15 MOPD Remote header Power from Store Panel Revisions Additional Notes Note Description Date By VERIFY DEFROST AMPS AND PHASE AT ORDER ENTRY 2 Changed remote header RH 1 to 114"07/17/23 RME Suction Headers with standard dip Tubes 3 Changed remote header RH 1 to 90"07/25/23 RME valves located on Remote Header. And loose for sub loops New Remote Header W/Receiver & Defrost panel Remote Header Power from Building Rlectrical Panel Check Actual Defrost Loads Per Circuit ^^Indicated Ship Loose Components “Refrigeration equipment supplier (OEM) to size and provide loose parts.” **Indicates RHD Components for Non-Circuit Information. All Components in Circuit Information are for RHD Only REMOTE HEADER 2A TO BE FED BY REMOTE HEADER 2B Circuit Information RH 2A Cir #Store Circ ID Model Size Description Type Comment HX Model TXV Model Load Evap Temp Disc Air Temp Liquid Valve Suction Valve Hot Gas Valve Def Type Def Volt Def Amp Def Ph Fan Volt Fan Amp Fan Phase Fan Watt Canopy Amp Nose Amp Shelf Amp Light Watt A/S Amp A/S Watt Run Rise Riser Size Suction Size Liquid Size Temp Sensor Qty RH 2A Main Pipes to DSS RH 2A Unknown Main Pipes to DSS 232,900 +18 A17464 AC17869 None None 2 5/8 2 5/8 7/8 1 23P Unknown 557 sq ft Unknown Meat Prep 27,900 +35 AQ17861 ORIT12-9 / EVR22-9 None Off Cycle 125 20 7/8 1 1/8 1/2 1 2 21G Unknown 6',8',12',12'Unknown M5XEP MD Meat 51,800 +26 AQ17861 EVR25-11 None Off Cycle 125 20 1 3/8 1 3/8 1/2 2 3 21A Unknown 12'Unknown M5XEP MD Meat 16,400 +26 AQ17860 EVR20-7 None Off Cycle 125 20 7/8 7/8 3/8 1 4 21F Unknown 12',12',12',12'Unknown M5XEP MD Deli 13,000 +32 AQ17860 A17464 None Off Cycle 125 20 5/8 7/8 3/8 2 5 Combo 22F Unknown Unknown Combo 32,000 +24 AQ17861 A17465 None Off Cycle 125 20 1 1/8 1 1/8 1/2 0 22F Unknown 838 sq ft Unknown Dairy Cooler w/ Doors +24 Existing Existing None Off Cycle 125 20 7/8 1 1/8 3/8 1 22F1 Unknown 8'Unknown D5XLEP MD Dairy +26 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 1 6 21B Unknown 8',8',12'Unknown D5LEP MD Meat 7,200 +32 AQ17860 ORIT6-5 / EVR6-5 None Off Cycle 125 20 1/2 5/8 3/8 2 7 Combo 22J,Q Unknown Unknown Combo 14,100 +20 AQ17860 A17464 None Off Cycle 125 20 7/8 7/8 3/8 0 22J Unknown 12'-4"x10'-3"x9'Unknown Bakery Retarder +26 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 1 22Q Unknown 1 qty Unknown BLF-59R Service Bakery +20 Existing Existing None Off Cycle 125 20 3/8 1/2 3/8 1 8 Combo D1,2,3 Unknown Unknown Combo 26,700 +20 AQ17861 A17465 None Off Cycle 125 20 1 1/8 1 1/8 1/2 0 22D1 Unknown 2 qty Unknown BLF-59SR SS Bakery +20 Existing Existing None Off Cycle 125 20 5/8 7/8 3/8 2 22D2 Unknown 12',12',12'Unknown ORBH French Door Dairy +32 Existing Existing None Off Cycle 125 20 1/2 5/8 3/8 2 22D3 Unknown 12',12',12'Unknown ORBH French Door Dairy +32 Existing Existing None Off Cycle 125 20 1/2 5/8 3/8 2 9 22K Unknown 838 sq ft Unknown Dairy Cooler w/ Doors 43,800 +24 AQ17861 A17466 None Off Cycle 125 20 1 1/8 1 3/8 1/2 1 10 Spare Spare Spare Spare Spare AQ17862 A17467 None None 125 20 1 3/8 1 5/8 5/8 1 Remote Header 2A 10 - Crkts, 90 inches Long 20.687" Wide x 74.5 High Max Dry Weight 951 LBS 208v/3 12.0 MCA 15 MOPD Remote header Power from Store Panel Revisions Additional Notes Note Description Date By VERIFY DEFROST AMPS AND PHASE AT ORDER ENTRY 2 Changed remote header RH 1 to 114"07/17/23 RME Suction Headers with standard dip Tubes 3 Changed remote header RH 1 to 90"07/25/23 RME valves located on Remote Header. And loose for sub loops New Remote Header W/Receiver & Defrost panel Remote Header Power from Building Rlectrical Panel Check Actual Defrost Loads Per Circuit ^^Indicated Ship Loose Components “Refrigeration equipment supplier (OEM) to size and provide loose parts.” **Indicates RHD Components for Non-Circuit Information. All Components in Circuit Information are for RHD Only M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B E RKHEIM E R ECHA N I C A LS TATEOF CA L I F AINR M O SALES PERSON PROJECT MANAGER REVISIONS RM.2B RA L P H S # 0 4 1 AR C A D I A , C A MI N O R C A P I T A L 21 1 E F O O T H I L L B L V D . , SCOTT THOPMSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 REFRIGERATION OEM SCHEDULE EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS APPLICABLE TO EACH TRADE. Customer Kroger Appl Eng Espinosa R.Quote 718488 Sales Order Order Lineup 1 Store RA-041 Rev Date 07/25/2023 Quote Rev R3 Order Rev Order Position 1 Location Arcadia, CA USA Draw Ref RA-041 R6.1 BPCS Item 4444 Physical Information Rack Discharge Component Information Rack Liquid Component Information Electrical Information Rack Model TZ500-038-UC-4-DSS2A-D Discharge Header Size 2 1/8 Condenser Return Connection Size 1 5/8 208/60/3 460/60/3 575/60/3 Rack Refrigerant R448A Oil Separator Model S-5394 Drop Leg Shut Off Valve Model ^^A-17467 Rack MCA 0.0 74.1 0.0 Rack Dimensions (D x H x W )30.5 x 78-1/16 x 45 Discharge Check Valve Model A17943 Drop Leg Check Valve Model ^^A17942 Rack MOPD 0 80 0 Est. Rack Lift Weight (lb)1,600 Discharge Pressure Regulator Model None Drop Leg Reg Valve Model None Condenser MCA (not from rack) Est. Rack Operating Weight (lb)Hot water HR Valve Model None Liquid Filter/Drier Shell Model ^^C-9611-G Condenser MOPD (not from rack) Rack Vibration Isolation None Hot Water HR Supply Connection Size None Liquid Filter/Drier Core Model ^^(2) RCW-48 Gold Receiver Style V Hot Water HR Return Connection Size None Liquid Supply Sightglass Model ^^A18121 Rack Control Voltage 208 Receiver Dimensions (DxL)^^12.75 x 67 Comfort HR Valve Model None Liquid Control Valve Model None Condenser Control Voltage 208 Receiver Insulation None Comfort HR Supply Connection Size None Liquid Shut Off Valve Model ^^A-17466 Receiver Pump-Down * (lb)452 Comfort HR Return Connection Size None Condenser to Rack Line Size 1 5/8 Compressor Controller See Controller DSS A * % Full @ 90°F Liquid 90%Split Condenser Valve Model None Defrost Controller Outdoor Design Dry Bulb °F +100.0 Condenser Supply Connection Size 2 1/8 Condenser Controller Outdoor Design Wet Bulb °F +73.0 Rack to Condenser Line Size 2 1/8 Max. Indoor Design Dry Bulb°F +75.0 Max. Indoor design HR%55% Condenser Information Model Fan Style FPI TD Net Weight Each Ship Weight Each Fan Qty Each Sections Wide Size Each FLA Each MCA Each MOPD Each Power Each (Watt) THR/TD Alt Corr THR/TD Relay Board in CBox Rack to Condenser Line Size Condenser to Rack Line Size Motor RPM Water Inlet Temp Water GPM Min Water GPM Max Water GPM Req'd Water Press Drop (psi) See Condenser DSS A Suction Group Performance Information Suction Group Suction Temp Cond Temp Target Liquid Temp Lvg Evap Load (Btuh) Comp Gross (Btuh) Natural Subcool (Btuh) Mech Subcool (Btuh) Suction Line (Btuh)NRE (Btuh) Excess Btuh (%) Comp Power (Watt) Comp THR (Btuh) THR Factor HR Avail (Btuh) Comp HP Total RLA Total Suction Accumulator Suction Filter Shell CCH Amp HCF Amp Subcooler Model Subcooler EPR SC TXV 1 SC TXV 2 SC EEV SC EEV Solenoid SC EEV Solenoid Coil D1 +28.0 +100.0 +100.0 471,800 401,303 0 0 0 401,303 -14.9%30,481 500,103 1.25 250,051 37 1/2 68.5 ^^BTAS-521SV 0.00 0.00 None None None None None None None Total +100.0 471,800 401,303 0 0 0 401,303 -14.9%30,481 500,103 1.25 250,051 37 1/2 68.5 0.00 0.00 Compressor Information Comp Location Number Suction Group Model HP NRE Watt THR RLA LRA Contactor Circuit Breaker Wire Size Unloader VFD Suction Accumulator Suction Shell Discharge Part CCH Amp HCF Amp Top 1 D1 ZBD57KCE-TFD-265 7 1/2 76,957 6,043 96,544 13.7 99.0 C25DRF330B PDG13F0025TFFJ 12 Digital None None None 0.00 None Top 2 D1 ZB57KCE-TFD-265 7 1/2 76,957 6,043 96,544 13.7 99.0 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Bottom 3 D1 ZB57KCE-TFD-265 7 1/2 76,957 6,043 96,544 13.7 99.0 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Bottom 4 D1 ZB57KCE-TFD-265 7 1/2 76,957 6,043 96,544 13.7 99.0 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Bottom 5 D1 ZB57KCE-TFD-265 7 1/2 76,957 6,043 96,544 13.7 99.0 C25DRF330B PDG13F0025TFFJ 12 None None None None 0.00 None Circuit Information Store Circ ID Model Size Description Type Comment HX Model TXV Model Load Evap Temp Disc Air Temp Liquid Valve Suction Valve Hot Gas Valve Def Type Def Volt Def Amp Def Ph Fan Volt Fan Amp Fan Phase Fan Watt Canopy Amp Nose Amp Shelf Amp Light Watt A/S Amp A/S Watt Run Rise Riser Size Suction Size Liquid Size Temp Sensor Qty Main Loop Main Loop D Main Pipes From DSS D Unknown Main Loop Sys D 471,800 +32 A17465 AC17869 None None 2 5/8 2 5/8 1 1/8 1 AC#1 Unknown Unknown Air Conditioning #1 345,500 +30 A17465 AC17869 None Off Cycle 125 20 2 5/8 2 5/8 1 1/8 1 2 AC#2 Unknown Unknown Air Conditioning #2 126,300 +30 A17464 A17468 None Off Cycle 125 20 2 1/8 2 1/8 7/8 1 Revisions Additional Notes Note Description Date By VERIFY DEFROST AMPS AND PHASE AT ORDER ENTRY 2 Changed remote header RH 1 to 114"07/17/23 RME Suction Headers with standard dip Tubes 3 Changed remote header RH 1 to 90"07/25/23 RME valves located on Remote Header. And loose for sub loops New Remote Header W/Receiver & Defrost panel Remote Header Power from Building Rlectrical Panel Check Actual Defrost Loads Per Circuit ^^Indicated Ship Loose Components “Refrigeration equipment supplier (OEM) to size and provide loose parts.” **Indicates RHD Components for Non-Circuit Information. All Components in Circuit Information are for RHD Only M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B ERKHEIM E R ECHA NI C A LS TATEOF CA L I F AINR M O SALES PERSON PROJECT MANAGER REVISIONS RM.2C RA L P H S # 0 4 1 AR C A D I A , C A MI N O R C A P I T A L 21 1 E F O O T H I L L B L V D . , SCOTT THOPMSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 REFRIGERATION OEM DANFOSS BOARD ASSIGNMENT EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS APPLICABLE TO EACH TRADE. M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B E RKHEIM E R ECHAN I C A LSTATEOFCALIF AINR M O SALES PERSON PROJECT MANAGER REVISIONS RM.3 RA L P H S # 0 4 1 AR C A D I A , C A . MI N O R C A P I T A L 21 1 E . F O O T H I L L B L V D . , SCOTT THOPMSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 WIRING SCHEMATIC EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS APPLICABLE TO EACH TRADE. M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B E RKHEIM E R ECHA N I C A LS TATEOF CA L I F AINR M O NOTE: **EXISTING REFRIGERATION EQUIPMENT IN COMPRESSOR ROOM TO BE REMOVED BY REFRIG. CONTR. UPON SWITCH OVER TO NEW REFRIG. OEM UNITS, COORDINATE WITH KROGER PROJECT MANAGER. ** FINAL LOCATION OF REFRIG. OEM UNITS & TRANSFORMERS (IF REQ'D) SHALL BE VERIFIED IN THE FIELD BY REFRIG. CONTRACTOR AND KROGER PROJECT MANAGER. ** "REFRIGERATION CONTRACTOR TO USE ANCHOR BOLTS TO SECURE RECEIVER TO THE FLOOR" NOTE: KROGER PROJECT MANAGER & REFRIG. CONTR. SEE REFRIG. OEM EQUIPMENT LEGEND FOR MORE INFORMATION. SALES PERSON PROJECT MANAGER REVISIONS RM.4 RA L P H S # 0 4 1 AR C A D I A , C A MI N O R C A P I T A L 21 1 E F O O T H I L L B L V D . , SCOTT THOPMSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 (E) MECH. ROOM, NEW REFRIG. OEM UNITS & MISC. DETAILS 1. GEN. CONTR. TO PROVIDE TEMPORARY SUPPORTS IF REQUIRED. ENGINEER & ARCHITECT. HUSSMANN.3. STRUCTURAL ENGINEER IS NOT PROVIDED BY LOCATIONS ARE TO BE APPROVED BY A STRUCTURAL 2. ALL GROUND MOUNTED EQUIPMENT AND GENERAL NOTES PIPE CHASE AT REFRIG. MECH. CENTER NOTE: GEN. CONTR. TO PROVIDE A STATE AND LOCAL CODE APPROVED CLEAR CURBED OPENING(S) FOR REFRIG. PIPING PENETRATION. VERIFY LOCATIONS WITH THE REFRIG. CONTR. AND ARCHITECT AND HAVE APPROVED BY A STRUCTURAL ENGINEER. ARCHITECT AND STRUCTURAL ENGINEER IS NOT SUPPLIED BY HUSSMANN. EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS APPLICABLE TO EACH TRADE. REFRIGERATION OEM UNIT DETAIL 1 RM.4 SAFETY PAN DETAIL 2 (E) MECH. ROOM W/ NEW REFRIGERATION OEM UNITS & REMOTE DEFROST PANEL (FOR REFERENCE ONLY)(FOR REFERENCE ONLY) RECEIVER PIPING DETAIL (FOR REFERENCE ONLY) 4 5 RM.4 RM.4 RM.4 3 (FOR REFERENCE ONLY) REFRIGERATION OEM REMOTE HEADER DETAIL SCALE 3/16" -1'-0" REFRIGERATION OEM UNIT DETAIL (FOR REFERENCE ONLY) RM.4 M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B E RKHEIM E R ECHAN I C A LSTATEOFCALIF AINR M O SEISMIC CALCULATION FOR KYSOR WARREN UNITS & REMOTE HEADERS SALES PERSON PROJECT MANAGER REVISIONS RM.4A RA L P H S # 0 4 1 AR C A D I A , C A EQ U I P M E N T R E P L A C E M E N T 21 1 E . F O O T H I L L B L V D . , SCOTT THOPMSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 SEISMIC CALC'S FOR REFRIG. OEM UNITS & HEADERS EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS APPLICABLE TO EACH TRADE. M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B E RKHEIM E R ECHAN I C A LSTATEOFCALIF AINR M O REFRIGERATION OEM SEISMIC ANCHORAGE CALCULATIONS SALES PERSON PROJECT MANAGER REVISIONS RM.4B RA L P H S # 0 4 1 AR C A D I A , C A EQ U I P M E N T R E P L A C E M E N T 21 1 E . F O O T H I L L B L V D . , SCOTT THOPMSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 REFRIGERATION OEM SEISMIC ANCHORAGE CALCULATIONS EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS APPLICABLE TO EACH TRADE. M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B E RKHEIM E R ECHAN I C A LS TATEOF CA L I F AINR M O SALES PERSON PROJECT MANAGER REVISIONS RM.5 RA L P H S # 0 4 1 AR C A D I A , C A MI N O R C A P I T A L 21 1 E . F O O T H I L L B L V D . , SCOTT THOMPSON ---- © HUSSMANN CORPORATION 2024 JULIO SOTO 909-548-2415 REFRIGERATION INSTALLATION DETAILS EQUIPMENT & INSTALLATION SHALL COMPLY WITH 2022 CALIFORNIA GREEN BUILDING STANDARD CODE SECTIONS 5.508, IT'S SUBSECTIONS & CODE SECTION 5.410.4.2 AS APPLICABLE TO EACH TRADE. M 31210 EXP. 12/31/25REGISTEREDPROFESSIONAL E N G I N R E E MAR K B E RKHEIM E R ECHA N I C A LS TATEOF CA L I F AINR M O E1.0 ELECTRICAL SYMBOLS AND GENERAL NOTES Project Number: 23-193.01 No.Issue Date Revisions 3/ 4 / 2 0 2 4 3 : 5 6 : 3 6 P M S: \ A C A D J F \ 2 0 2 3 \ Y 2 3 - 2 7 2 R A 0 4 1 A r c a d i a - R e f . ( r d c ) \ E l e c \ 2 0 2 4 - 0 3 - 0 4 B I D S E T \ E 1 . 0 E L E C S Y M B O L A N D G E N NO T E S . d w g 11 0 0 W E S T A R T E S I A B O U L E V A R D CO M P T O N , C A L I F O R N I A 9 0 2 2 0 RA L P H S G R O C E R Y C O . RA L P H S # 0 4 1 RE F R I G . E Q U I P M E N T R E P L A C E M E N T 21 1 E . F O O T H I L L B L V D . AR C A D I A , C A E2.0 OVERALL ELECTRICAL PLAN Project Number: 23-193.01 No.Issue Date Revisions 3/ 4 / 2 0 2 4 3 : 5 6 : 4 3 P M S: \ A C A D J F \ 2 0 2 3 \ Y 2 3 - 2 7 2 R A 0 4 1 A r c a d i a - R e f . ( r d c ) \ E l e c \ 2 0 2 4 - 0 3 - 0 4 B I D S E T \ E 2 . 0 O V E R A L L E L E C T . P L A N . d w g 11 0 0 W E S T A R T E S I A B O U L E V A R D CO M P T O N , C A L I F O R N I A 9 0 2 2 0 RA L P H S G R O C E R Y C O . RA L P H S # 0 4 1 RE F R I G . E Q U I P M E N T R E P L A C E M E N T 21 1 E . F O O T H I L L B L V D . AR C A D I A , C A UP E3.0 ENLARGED POWER PLAN Project Number: 23-193.01 No.Issue Date Revisions 3/ 4 / 2 0 2 4 3 : 5 7 : 1 3 P M S: \ A C A D J F \ 2 0 2 3 \ Y 2 3 - 2 7 2 R A 0 4 1 A r c a d i a - R e f . ( r d c ) \ E l e c \ 2 0 2 4 - 0 3 - 0 4 B I D S E T \ E 3 . 0 E N L A R G E D P O W E R P L A N - ME Z Z A N I N E L E V E L . d w g 11 0 0 W E S T A R T E S I A B O U L E V A R D CO M P T O N , C A L I F O R N I A 9 0 2 2 0 RA L P H S G R O C E R Y C O . RA L P H S # 0 4 1 RE F R I G . E Q U I P M E N T R E P L A C E M E N T 21 1 E . F O O T H I L L B L V D . AR C A D I A , C A E4.0 SINGLE LINE DIAGRAM Project Number: 23-193.01 No.Issue Date Revisions 3/ 4 / 2 0 2 4 3 : 5 6 : 5 2 P M S: \ A C A D J F \ 2 0 2 3 \ Y 2 3 - 2 7 2 R A 0 4 1 A r c a d i a - R e f . ( r d c ) \ E l e c \ 2 0 2 4 - 0 3 - 0 4 B I D S E T \ E 4 . 0 S I N G L E L I N E D I A G R A M . d w g 11 0 0 W E S T A R T E S I A B O U L E V A R D CO M P T O N , C A L I F O R N I A 9 0 2 2 0 RA L P H S G R O C E R Y C O . RA L P H S # 0 4 1 RE F R I G . E Q U I P M E N T R E P L A C E M E N T 21 1 E . F O O T H I L L B L V D . AR C A D I A , C A Project Number: 23-193.01 No.Issue Date Revisions 3/ 4 / 2 0 2 4 3 : 5 6 : 5 8 P M S: \ A C A D J F \ 2 0 2 3 \ Y 2 3 - 2 7 2 R A 0 4 1 A r c a d i a - R e f . ( r d c ) \ E l e c \ 2 0 2 4 - 0 3 - 0 4 B I D S E T \ E 4 . 1 P A N E L S C H E D U L E S . d w g 11 0 0 W E S T A R T E S I A B O U L E V A R D CO M P T O N , C A L I F O R N I A 9 0 2 2 0 RA L P H S G R O C E R Y C O . RA L P H S # 0 4 1 RE F R I G . E Q U I P M E N T R E P L A C E M E N T 21 1 E . F O O T H I L L B L V D . AR C A D I A , C A E4.1 PANEL SCHEDULE E5.0 WIRING SCHEMATIC DIAGRAM Project Number: 23-193.01 No.Issue Date Revisions 3/ 4 / 2 0 2 4 3 : 5 7 : 0 5 P M S: \ A C A D J F \ 2 0 2 3 \ Y 2 3 - 2 7 2 R A 0 4 1 A r c a d i a - R e f . ( r d c ) \ E l e c \ 2 0 2 4 - 0 3 - 0 4 B I D S E T \ E 5 . 0 W I R I N G D I A G R A M . d w g 11 0 0 W E S T A R T E S I A B O U L E V A R D CO M P T O N , C A L I F O R N I A 9 0 2 2 0 RA L P H S G R O C E R Y C O . RA L P H S # 0 4 1 RE F R I G . E Q U I P M E N T R E P L A C E M E N T 21 1 E . F O O T H I L L B L V D . AR C A D I A , C A A.I. LIQ.LEV. A.I. DROP. LEG A.I. TRANS DROP. LEG TEMP R.O. RECLAIM HEAT A.I. AMBIENT TEMP A.I. LIQ.LEV. A.I. DROP. LEG A.I. TRANS DROP. LEG TEMP R.O. RECLAIM HEAT A.I. AMBIENT TEMP R.O. REFRIGL1L2 208/1 VOLTAGE CONTROL A.I. TEMPPROBE A.I. TEMPPROBE R.O. REFRIGL1L2 208/1 VOLTAGE CONTROL A.I. TEMPPROBE A.I. TEMPPROBE A.I. LIQ. LEV.A.I. DROPLEG A.I.TRANS DROPLEG TEMP A.I. AMBIENT TEMP L1 L2 208/1 VOLTAGE CONTROL R.O.DEFROST R.O.REFRIG D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE R.O.DEFROST R.O.FAN R.O.REFRIGL1L2 208/1 VOLTAGE CONTROL R.O.DEFROST R.O.FAN R.O.REFRIGL1L2 208/1 VOLTAGE CONTROL D.I. DOORSW. D.I.D.I. DOORSW. D.I. L1 L2 208/1 VOLTAGE CONTROL R.O.DEFROST R.O.REFRIG D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DUAL TEMPSWITCH D.I. L1 L2 208/1 VOLTAGE CONTROL R.O.DEFROST R.O.REFRIG D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE R.O.DEFROST R.O.FAN R.O.REFRIGL1L2 208/1 VOLTAGE CONTROL D.I. DOORSW. D.I. R.O. REFRIGL1L2 208/1VOLTAGE CONTROL A.I. TEMPPROBE A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE R.O. REFRIGL1L2 208/1VOLTAGE CONTROL R.O. REFRIGL1L2 208/1VOLTAGE CONTROL A.I. TEMPPROBE A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE D.I. DEF.TERM. A.I. TEMPPROBE R.O. REFRIGL1L2 208/1VOLTAGE CONTROL