HomeMy WebLinkAbout1215 W Huntington Dr - 2024 - Amy Tran DDSFI N I S H P L A N A N D S C H E D U L E NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A A8 FINISH PLAN N UTILITY BREAK ROOM PRIVATE OFFICE STERILIZATION DENTAL WORK AREA UNISEX REST ROOM RECEPTION BUSINESS OFFICE CONSULTATION DENTAL IMAGING EXAM 1 EXAM 2 EXAM 4 EXAM 5 HA L L W A Y FINISH SCHEDULE ACT-1 ACOUSTICAL CEILING TILES: ARMSTRONG, STYLE: 24" X 48" OPTIMA PL-1 PLASTIC LAMINATE: WILSONART COLOR: PEPPERDUST D327-60 PL-2 PLASTIC LAMINATE: CPS GARTEN, INTERIOR ARTS COLOR: 3104 VNR EASTERN WALNUT PL-3 PLASTIC LAMINATE: OCTOLAM COLOR:1176 WHITE WEAVE (CONTACT: LOUIE ESQUEDA 714. 472.5650) PL-4 PLASTIC LAMINATE: OCTOLAM COLOR: LUCENTA 1179 (CONTACT: LOUIE ESQUIDA 714.472.5650) PL-5 PLASTIC LAMINATE: WILSONART COLOR: LINEN D427-60 PL-6 PLASTIC LAMINATE: OCTOLAM COLOR:Z106 AFP GREY (CONTACT: LOUIE ESQUEDA 714. 472.5650) AP-1 PREFABRICATED PANEL: EB BRADLEY, ALVIC LUX, COLOR: BLANCO, GLOSS FINISH, (CONTACT: JUSTIN CASTILLO 714.493.9960) VP-1 VINYL PLANKS: GERFLOR, CREATION 30/55 CLICK COLOR: 0848 SWISS OAK BEIGE, 8.4" X 48.8", (CONTACT: JON TORRES 949.484.3058) FT-1 PORCELAIN FLOOR TILE, PORCELANOSA, BUTAN BONE, SIZE: 23" X 23", (CONTACT: RUHAMAH SOLEM 714.264.7706) NON-SANDED GROUT, 1/16", PORCELANOSA, COLORSTUK, COLOR: TBD WT-1 PORCELAIN WALL TILE, PORCELANOSA, SPIGA BUTAN, SIZE: 18" X 47" (CONTACT: RUHAMAH SOLEM 714.264.7706) NON-SANDED GROUT, 1/16", PORCELANOSA, COLORSTUK, COLOR: TBD QZ-1 QUARTZ SURFACE: PREFABRICATED QUARTZ, COLOR: WHITE (PURCHASE HALF SLAB) SS-1 SOLID SURFACE: CORIAN, COLOR: VENERO WHITE WC-1 WALL COVERING (BY OWNER): TECNO GRAFICA, STYLE: BREATH, FRESH, (CONTACT: ROMINA 858.336.2219) WC-2 WALL COVERING (BY OWNER): CARNEGIE, DASH 6603, COLOR 35, PAPER BACK, (CONTACT: KIMBERLY MCCREADY 562.533.6777) WC-3 WALL COVERING (BY OWNER): CARNEGIE, NILE EMBOSS 6293W, COLOR: 765, COLOR 3, PAPER BACK (CONTACT: KIMBERLY MCCREADY 562.533.6777) B-1 4" STRAIGHT EDGE MDF BASE, PAINTED P-1 SB-1 1.5" SCHLUTER SS COVED BASE P-1 PAINT (GENERAL/CEILING) DUNN EDWARDS, COLOR: DEW 380 WHITE, EGGSHELL FINISH P-2 PAINT (ACCENT PAINT) DUNN EDWARDS, COLOR: TBD, EGGSHELL FINISH P-3 PAINT (ACCENT PAINT) DUNN EDWARDS, COLOR: TBD, EGGSHELL FINISH P-4 PAINT (DOOR FACE) DUNN EDWARDS, COLOR:DET 600 DOLPHIN TALES, SEMI GLOSS FINISH NOTES: - INTERIOR 8'-0" DOORS (TYPE A): SOLID DOORS PAINTED: P-4. - PROVIDE BLACK PULL CABINETS HARDWARE. - PROVIDE BLACK FAUCET AT RESTROOM. - A-DEC: DENTAL CHAIR VINYL, CHARCOAL, 12 O'CLOCK CAB: SABLE, SOLID SERVICE COUNTER TOP: DESIGNER WHITE. 5 2 CONSULTATION NTS   8PRIVATE OFFICE NTS CLB4 1RECEPTION AREA NTS A B RECEPTION DESK GLASS DOOR/ WALL A B RECEPTION DESK RECEPTION WALL FURTURE LOGO RECEPTION AREA NTS B C BACK COUNTER FRONT COUNTER EXAM ROOMS NTS C B TYP. CABINETS @ EXAM ROOMS EXAM ROOM 5 BREAK ROOM NTS A C STAFF LOUNGE GLASS WALL A D CABINETS @ PRIVATE OFFICE CABINETS @ PRIVATE OFFICE FI N I S H P L A N A N D S C H E D U L E NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A A9 1UNISE; RESTROOM NTS 119 C D LAB LAB LAB NTS A DRESTROOM STERILE NTS A C STERILE STERILE ALAB RESTROOM BRESTROOM C RESTROOM HALLWAY NTS 12 DBENCH BHALLWAY HALLWAY NTS 1 -HALLWAY DOOR SCHEDULE NTS 1 DOOR TYPE HARDWARE TYPES Type Description A Type Description of HAGER hardware A LEVER HANDLE- LOCKSET FINISH: TBD B B LEVER HANDLE- PRIVACY FINISH: TBD C LEVER HANDLE- PASSAGE FINISH: TBD D NON LATCHING 42" DOOR PULL BACK TO BACK; FINISH: TBD E NON LATCHING BARN DOOR PULL - FINISH: TBD F LATCHING DOOR PULL G MAIN ENTRY HARDWARE; (E) TO REMAIN DOOR ELEVATIONS C Door Number Door Type Hardware Type Door Size Notes: 105.1 DOOR SCHEDULE 101.1 C D DOOR: Framed glass FRAME: metal 1.5" 110.1 A A B D 3'-0" x 7'-6" 3'-0" x 7'-6" Room Name RECEPTION CONSULATION 3'-0" x 7'-6" EXAM RM. 1 108.1 B D 3'-0" x 7'-6" PRIVATE OFFICE 109.1 B D 3'-0" x 7'-6" DOOR: Paint grade glass inset pocket door with hardware FRAME: - 103.1 JAN. CLOSET 3'-0" x 7'-6"A A DOOR: Paint grade swing door with hardware FRAME: Western Integrated door frames. Provide integral door sweep 111.1 DOOR: Paint grade glass inset pocket door with hardware FRAME: - DOOR: Paint grade glass inset pocket door with hardware FRAME: -EXAM RM. 5 B D 3'-0" x 7'-6" DOOR: Paint grade glass inset pocket door with hardware FRAME: -BREAK RM B C 3'-0" x 7'-6"DENTAL WORK AREA113.1 A B 3'-0" x 7'-6"UNI-SEX RESTROOM114.1 DOOR: Paint grade glass inset pocket door with hardware FRAME: - DOOR: Paint grade glass inset pocket door with hardware FRAME: - DOOR: Paint grade swing door with hardware FRAME: Western Integrated door frames. Provide integral door sweep SWING DOOR ASSEMBLY POCKET DOOR ASSEMBLY METAL FRAMED GLASS DOOR Door Notes: All doors with a latch and lock to have a single action hardware which reacts both lock and latch from the exit side with a single operation (CBC 1008.1.9.5). DOOR NOTES: 1.AFFIX INTERNATIONAL ACCESSIBILITY SYMBOL ON ALL ACCESSIBLE ENTRANCES. CBC 11B-216.6 2.ALL REQUIRED ENTRY DOORWAYS ARE TO BE 3'-0" X 6'-8” HIGH AND WILL PROVIDE A 32” MINIMUM CLEAR OPENING WIDTH, MEASURED WHEN THE DOOR IS OPENED AT 90 DEGREES. CBC 11B-404.2 3.ENTRY/ PASSAGE DOORS SHALL HAVE LEVER TYPE HARDWARE, PUSH-PULL HARDWARE, OR HARDWARE THAT DOES NOT REQUIRE THE ABILITY TO GRASP AND TWIST IN A SINGLE MOTION. CBC 11B-404.2.7 4.HAND ACTIVATED DOOR HARDWARE SHALL BE CENTERED BETWEEN 34” AND 44” A.F.F. CBC 11B-404.2.7 5.A 60” MINIMUM LEVEL LANDING (2” MAX SLOPE) IN DIRECTION OF DOOR SWING, MEASURED WITH THE DOOR CLOSED, AND 48” IN OPPOSITE DIRECTION OF THE DOOR, IS ACCEPTABLE WHEN THE APPROACH OR WHEN THERE IS NEITHER A LATCH OR CLOSURE AND HINGE SIDE APPROACH ONLY. CBC 11B-404.2 6.THE DOOR LANDING EXTENDS 24” PAST THE STRIKE EDGE OF INTERIOR DOORS. A 12” CLEAR SPACE IS REQUIRED AT THE STRIKE EDGE OF THE PUSH SIDE OF A PASSAGE DOOR WHEN THERE IS BOTH A LATCH AND A CLOSURE. MANEUVERING CLEARANCES PER TABLE 11B-404.2.4.1. 7.THE MAXIMUM VERTICAL HEIGHT OF A PASSAGE DOOR THRESHOLD IS ¼: OR UP TO ½” IF THERE IS A 1:2 MAXIMUM BEVELED SLOPE. CBC 11B-404.2.5 8.THE BOTTOM OF THE PUSH SIDE OF ALL PASSAGE DOORS, EXCEPT AUTOMATIC AND SLIDING, REQUIRE A 10” HIGH SMOOTH SURFACE. CBC 11B-404.2.10 9.THE MAXIMUM EFFORT TO OPEN AN INTERIOR DOOR IS 5 LBS. EXTERIOR DOORS ARE 5 LBS. AND 15 LBS. MAX. FOR FIRE RATED EXIT DOORS. CBC 11B-404.2.9 10.REGARDLESS OF OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHERE THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING, “THIS DOOR TO REMAIN UNLOCKED DURING WHEN BUILDING IS OCCUPIED” THE LETTERS SHALL BE NOT LESS THAN 1” HIGH ON A CONTRASTING BACKGROUND. (CBC 1008.1.9.3#2 2.2) 11.HARDWARE AT POCKET DOORS SHALL BE ADA COMPLIANT; USING LEVER TYPE HAEGER WROUGHT DOOR PULLS #36 8” OR EQUAL USING RUBBER STOPS ON BOTTOM OF DOORS TO PREVENT DOOR HARDWARE FRAME CONTACT 8.THE BOTTOM 10” OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10” HIGH SMOOTH PANEL SHALL BE INSTALLED IN THE PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. CBC 11B-404.2.10 9.A NARROW FRAME, WITH A BEVELED TOP EDGE 60 DEGREES MAXIMUM BEVEL TO VERTICAL PLANE INSTALLED AT BOTTOM OF A GLASS DOOR (WITH NO SIDE FRAMES) MAY BE USED IN LIEU OF PROVIDING THE REQUIRED 10” UNINTERRUPTED SURFACE AT THE BOTTOM OF THE DOOR. SUBJECT TO AHJ APPROVAL CBC 11B-404.2.10 10.WHEN SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. (11B-404.2.7) WE S T H U N T I N G T O N D R I V E ADJACENT BLDG (E) MASONRY SCREENING WALL; TO BE REMOVED ADJACENT SUITE DR. AMY TRAN OFFICE 1215 WEST HUNTINGTON DRIVE 1-STORY / 1825 SF (E) PLANTING AREA; TO BE REMOVED (E) PLANTING AREAS; TO BE PARTIALLY REMOVED (E) TREES #4 and #5; TO REMAIN (E) TREE #2; TO BE REMOVED (E) C.M.U. CURB; THIS PORTION TO BE REMOVED FOR ADA RAMP. (E) TREE #1; TO BE REMOVED (E) PLANTING AREA; TO BE PARTIALLY REMOVED TO ACCOMMODATE ADA RAMP PROPERTY LINE (E) C.M.U. LOW RETAINING GARDEN WALL, TO REMAIN. REPAIR AS NEEDED. (E) ADDRESS NO. SIGN; TO BE LOCATED. (E) BUSINESS SIGNAGE; TO BE REMOVED AND REPLACED WITH NEW MONUMENT STYLE SIGN IN ACCORDANCE WITH CITY OF ARCADIA ZONING CODE 9103.11 (E) WOOD PRIVACY FENCE (E) ASPHALT PARKING LOT TO REMAIN; REFER TO ARCHITECT DWGS FOR PROPOSED MODIFICATIONS. PROPERTY LINE (E) PUBLIC SIDEWALK (E) TREE #3; TO BE REMOVED ADJACENT BLDG ADJACENT SUITE DR. AMY TRAN OFFICE 1215 WEST HUNTINGTON DRIVE 1-STORY / 1825 SF (E) WOOD PRIVACY FENCEPROPERTY LINE WE S T H U N T I N G T O N D R I V E (N) ADA WALKWAY; REFER TO ARCH DWGS (E) MODIFIED PLANTING AREA (N) ADA PKG SPACE; REFER TO ARCH DWGS FOR DETAILS (E) MODIFIED PLANTING AREA ALIGN (N) 6" CONC CURB; REPLACE EX. ASPHALT PLANTING CURB (N) 6" CONC CURB; REPLACE EX. ASPHALT PLANTING CURB (N) ADA RAMP; REFER TO ARCH DWGS (N) RIVER ROCK, MORTAR JOINTS (N) MODIFIED PLANTING AREA (E) RELOCATED ADDRESS NO. SIGN (E) MODIFIED PLANTING AREA (N) MONUMENT SIGN, SETBACK 5' FROM ALL PROPERY LINES, 6' HIGH WITH BASE, WIDTH NOT TO EXCEED 1.5 TIMES HEIGHT (1) GIN AUT 24" box (12) ZEP CAN 4" pot (5) OLE LIT 5 gal. (6) RHA MIN 5 gal. (28) WES MSU 1 gal. (8) ZEP CAN 4" pot 5'-0" 5' - 0 " (7) RHA MIN 5 gal. (11) PIT W14 5 gal. BOTANICAL / COMMON NAME DIAM HEIGHT EX. #1 EX. #2 EX #3 6" 18" NOTES - REMOVE OR RETAIN EX. #4 EX. #5 Acer palmatum Japanese Maple TO BE REMOVED. Small Accent Tree, Fair to Good Condition. Required to be removed for installation of ADA ramp. 12' - 16' 8'-10' EXISTING TREE SCHEDULE SYMBOL TREE # Pinus spp. Stone Pine Pinus spp. Stone Pine Podocarpus gracilor African Fern Pine Podocarpus gracilor African Fern Pine 18"12' - 16' 14"25' - 30'' 14"25' - 30'' TO BE REMOVED. Fair Condition. Required to be removed for installation of ADA path of travel to entry. TO BE REMOVED. Fair Condition. Required to be removed for installation of ADA path of travel to entry. TO BE RETAINED. Fair to Good Condition. Protect in place throughout construction. TO BE RETAINED. Fair to Good Condition. Protect in place throughout construction. SYMBOL CODE BOTANICAL / COMMON NAME SIZE WATER USE FOLIAGE QTY TREES GIN AUT Ginkgo biloba 'Autumn Gold' Autumn Gold Maidenhair Tree 24" box M Deciduous 1 EXISTING TREES TO REMAIN POD GRA Podocarpus gracilior Fern Pine EX L Evergreen 2 SYMBOL CODE BOTANICAL / COMMON NAME SIZE WUCOLS TYPE QTY SHRUBS OLE LIT Olea europaea 'Montra' Little Ollie® Olive 5 gal.L Evergreen 5 PIT W14 Pittosporum tobira 'Wheeler's Dwarf' Wheeler's Dwarf Pittosporum 5 gal.L Evergreen 11 RHA MIN Rhaphiolepis umbellata 'Minor' Dwarf Yedda Hawthorn 5 gal.L Evergreen 13 WES MSU Westringia fruticosa 'NFL25' Mundi™ Coast Rosemary 1 gal.L Evergreen 28 ZEP CAN Zephyranthes candida Zephyrlily 4" pot L Deciduous 20 PROPOSED PLANT SCHEDULE SYMBOL DESCRIPTION QTY Mexican Beach Pebble, Black, 1-2" size 293 sf Organic Mulch, Superfine Mulch from CalBlend Soils or similar.291 sf Boulder, Buried 1/3 deep, mortar set. Re-Use existing or new boulders, tbd. 6 LANDSCAPE MATERIALS SCHEDULE 1/8" = 1'-0" LANDSCAPE SITE PLAN - EXISTING 1 L-1 LANDSCAPE PLAN 0 SCALE: 1/8" = 1'-0" 8'16'4' 1/8" = 1'-0" LANDSCAPE SITE PLAN - PROPOSED2 Owner Name: Amy Tran, D.D.S Owner Address: 1215 W. Huntington Drive Arcadia, CA 91007 DRAWING SUBMITTAL LANDSCAPE ARCHITECT STAMP (NOT FOR CONSTRUCTION) DATE: PROJECT #: 24-CL-03 DRAWN BY:SR CHKD BY: DWG # SEPTEMBER 3, 2024 Date Description PROJECT TR$N %UI/'IN*  : +XQWLQJWRQ 'ULYH $UFDGLD C$  DDWH RHQHZDO DDWH SLJQDWXUH  ARCHITECT T. Michael Hadley & Associates 219 Calle Damante Sedona, AZ 747-323-6227 mhadleyarchitect@gmail.com 9/3/24 Landscape Plan Submittal #1 TREE PROTECTION NOTES: 1.ALL EXISTING TREES & PLANTS TO REMAIN NOTED ON LANDSCAPE DWGS ARE TO BE PROTECTED IN PLACE THROUGHOUT PROJECT CONSTRUCTION AND SHALL NOT INCUR ANY PHYSICAL DAMAGE TO LIMBS, BARK, CROWN OR WHERE ROOTS JOIN STEM. 2.ANY PRUNING / TRIMMING OF EXISTING TREES & PLANTS REQUIRED FOR CONSTRUCTION TO BE CONDUCTED BY CERTIFIED ARBORIST AND APPROVED BY LANDSCAPE ARCHITECT. 3.WITHIN DRIPLINES OF TREES TO REMAIN: 3.1.AVOID DISTURBANCE TO TREE, ROOTS AND SOIL. DO NOT MAKE GRADE CHANGES FROM EXISTING GRADE GREATER THAN 6". AT NO TIME DURING OR AFTER CONSTRUCTION SHOULD SOIL BE IN CONTACT WITH THE TRUNK OF ANY TREE ABOVE NATURAL GRADE. 3.2.TREEROOT FLARE SHOULD BE VISIBLE AT ALL TREES. 3.3.NO HEAVY MACHINERY, MECHANICAL TRENCHING OR MATERIAL STORAGE SHALL BEPERMITTED. CORE AERATOR, TOP-DRESSING MACHINE, AIR SPADING, HAND DIGGING OR OTHER APPROVED METHOD OF DIGGING, DEMOLITION AND TRENCHING SHALL BE USED TO COMPLETE WORK IN TREE PROTECTION AREA/PROTECTED ROOT ZONES. 3.4.ANY REQUIRED TRENCHING SHOULD BE ROUTED TO MINIMIZE ROOT DAMAGE ADN CUTTIN OF ROOTS SHOULD BE AVOIDED BY PLACING PIPES AND CABLES ABOVE OR BELOW UNCUT ROOTS. TREE REMOVAL NOTES: 1.NO TREES PROPOSED FOR REMOVAL ARE PROTECTED PER CITY OF ARCADIA TREE PRESERVATION ORDINANCE. 2.ALL TREE REMOVALS TO BE CONDUCTED BY LICENSED CONTRACTOR AND TO INCLUDE STUMP GRINDING. GENERAL IRRIGATION NOTES: 1.ALL LANDSCAPING SHALL BE INSTALLED WITH A PERMANENT IRRIGATION SYSTEM.DRIP IRRIGATION TO BE USED FOR ALL PLANTING AREAS EXCEPT TEH NEW LAWN. 2.GIVEN THAT GREATER THAN 500 SF OF LANDSCAPE WILL BE MODIFIED, PLANTING AND IRRIGATION PLANS SHALL CONFORM TO THE MOST CURRENT MWELO REQUIREMENTS FOR THE STATE OF CALIFORNIA. 3.AN AUTOMATED IRRIGATION CONTROLLER AND RAIN SHUT-OFF DEVICE WILL BE UTILIZED TO MAXIMIZE THE EFFICIENCY OF WATER USE ON SITE. ALL VALVES SHALL BE LOCATED IN VALVE BOXES BELOW GRADE AND SHALL INCLUDE BALL-VALVE SHUT-OFFS. CONTROLLER TO BE MOUNTED IN AN ACCESSIBLE LOCATION EASILY ACCESSED BY THE GARDENER AND CLIENT. 4.ALL DRIP POLYTUBING SHOULD BE ANCHORED WITH SOD STAPLES 2” BELOW GRADE SO AS NOT TO SURFACE ABOVE THE MULCH LINE. 5.TREES AND SHRUBS TO BE ON SEPARATE VALVES. TWO BUBBLERS PER TREE TO BE INSTALLED. 6.INSTALLATION OF LANDSCAPE MATERIALS AND IRRIGATION EQUIPMENT SHALL BE IN ACCORDANCE WITH COMMONLY ACCEPTED METHODS OF INSTALLATION AS APPROVED BY THE LANDSCAPE ARCHITECT. 7.LANDSCAPING AND IRRIGATION SHALL BE INSTALLED IN COMPLIANCE WITH ANY APPROVED SITE PLAN OR OTHER PROJECT APPROVAL PRIOR TO FINAL INSPECTION OR OCCUPANCY. GENERAL PLANTING & SOIL NOTES: 1.ALL PLANTS TO BE DROUGHT TOLERANT AND APPROPRIATE FOR SOUTHERN CALIFORNIA CLIMATE. 2.ALL PLANTED AREAS SHALL HAVE 3" ORGANIC WOOD MULCH APPLIED.UNLESS OTHERWISE NOTED TO HAVE MEXICAN BEACH PEBBLE. MULCH TO BE KEPT BACK 6" FROM THE ROOT FLARE OF ALL TREES AND SHRUBS. 3.PLANTS SHALL BE OF RETAIL NURSERY QUALITY. ALL PLANT MATERIAL SHALL BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 4.CONTRACTOR TO COMPLETE ALL SOIL AMENDING, FINISH GRADING AND REMOVAL OF ANY AND ALL CONSTRUCTION DEBRIS FROM THE PLANTING AREAS BEFORE THE LAYING OUT OF APPROVED PLANT MATERIAL. 5.BACKFILL MIX SHALL CONSIST OF 1/3 IMPORTED ORGANIC COMPOST AND 2/3 AMENDED SITE SOIL. 6.IMMEDIATELY AFTER EXCAVATION OF PLANT PITS, TEST DRAINAGE OF PITS BY FILLING WITH WATER. GIVE WRITTEN NOTIFICATION OF CONDITIONS PERMITTING THE RETENTION OF WATER IN PITS FOR MORE THAT (3) HOURS. CONTRACTOR SHALL SUBMIT TO OWNER AND LANDSCAPE ARCHITECT FOR ACCEPTANCE A WRITTEN PROPOSAL AND COST ESTIMATE FOR THE CORRECTION OF POOR DRAINAGE CONDITIONS BEFORE PROCEEDING WITH PLANTING. 7.ALL QUANTITIES AND AMOUNTS SHOWN ON THE PLANS ARE BEST ESTIMATES FOR THE BENEFIT OF THE CONTRACTOR. IN FIELD CONDITIONS MAY VARY COMPARED TO WHAT IS SHOWN ON THE PLANS. THEREFORE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL LENGTHS, SQUARE FOOTAGES, AND AMOUNTS PRIOR TO BIDDING THE PROJECT. 8.LANDSCAPING MAINTENANCE. ALL LANDSCAPED AREAS VISIBLE FROM PUBLIC STREETS SHALL BE MAINTAINED IN A NEAT, CLEAN, ORDERLY AND HEALTHFUL CONDITION. L-2 LANDSCAPE DETAILS AND NOTES 0 8'4'16'2' SCALE: 3/16" = 1'-0" Owner Name: Amy Tran, D.D.S Owner Address: 1215 W. Huntington Drive Arcadia, CA 91007 DRAWING SUBMITTAL LANDSCAPE ARCHITECT STAMP (NOT FOR CONSTRUCTION) DATE: PROJECT #: 24-CL-03 DRAWN BY:SR CHKD BY: DWG # SEPTEMBER 3, 2024 Date Description PROJECT TR$N %UI/'IN*  : +XQWLQJWRQ 'ULYH $UFDGLD C$  Date Renewal Date Signature 01/31/25 ARCHITECT T. Michael Hadley & Associates 219 Calle Damante Sedona, AZ 747-323-6227 mhadleyarchitect@gmail.com 9/3/24 Landscape Plan Submittal #1 Top of root ball shall be flush with finished grade. Trunk caliper shall meet ANSI Z60 current edition for root ball size. Root ball modified as required. Existing soil. Slope sides of loosened soil. Prior to mulching, lightly tamp soil around the root ball in 6" lifts to brace tree. Do not over compact. When the planting hole has been backfilled, pour water around the root ball to settle the soil. 4" layer of mulch. No more than 1" of mulch on top of root ball. (See specifications for mulch). Bottom of root ball rests on existing or recompacted soil. Central leader. (See crown observations detail). SECTION VIEW Round-topped soil berm 4" high x 8" wide above root ball surface shall be constructed around the root ball. Berm shall begin at root ball periphery. Notes: 1- Trees shall be of quality prescribed in crown observations and root observations details and specifications. 2- See specifications for further requirements related to this detail. Finished grade. 3x widest dimension of root ball. Loosened soil. Dig and turn the soil to reduce compaction to the area and depth shown. TREE W/ BERM - UNMODIFIED SOIL1 P-CO-03 Notes: 1- Shrubs shall be of quality prescribed in the root observations detail and specifications. 2- See specifications for further requirements related to this detail. Loosened soil. Dig and turn the soil to reduce the compaction to the area and depth shown. 3x's widest dimension of root ball. Rootball. 4" high x 8" wide round - topped soil berm above root ball surface shall be constructed around the root ball. Berm shall begin at root ball periphery. Prior to mulching, lightly tamp soil around the root ball in 6" lifts to brace shrub. Do not over compact. When the planting hole has been backfilled, pour water around the root ball to settle the soil. 4" layer of mulch. No more than 1" of mulch on top of root ball. (See specifications for mulch). Root ball rests on existing or recompacted soil. Slope sides of loosened soil. Existing soil. Finished grade. Shrub. SECTION VIEW SHRUB - UNMODIFIED SOIL2 P-CO-02 EQ. EQ . Notes: 1- See planting legend for groundcover species, size, and spacing dimension. 2- Small roots (14" or less) that grow around, up, or down the root ball periphery are considered a normal condition in container production and are acceptable however they should be eliminated at the time of planting. Roots on the periperhy can be removed at the time of planting. (See root ball shaving container detail). 3- Settle soil around root ball of each groundcover prior to mulching. PLAN SECTION VIEW Pavement. Mulch. Groundcover plants to be triangularly spaced. Existing soil. Modified soil. Depth varies. (See specifications for soil modification). 2 - 3" thick layer of mulch. Finished grade. 6" m i n . GROUNDCOVER3 P-CO-01 PITTOSPORUM 'WHEELER'S DWARF' ZEPHYRENTHES, RAIN LILY PROPOSED TREES, PLANTS AND LANDSCAPE MATERIALS: LITTLE OLLIE SHRUB BOULDERS ORGANIC MULCH GINGKO BILOBA, AUTUMN GOLD, MALE ONLY BEACH PEBBLES, 1-2" BLACKRAHPHIOLEPSIS UMBELLATA MINOR, DWARF YEDDO HAWTHORN WATER EFFICIENT LANDSCAPE WORKSHEET : AUSTRALIAN ROSEMARY, WESTRINGIA MUNDI NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 10 WHVW RR[EXU\ SWUHHW 2 -15  JOB 2-22 WHVW CRYLQD, CDOLIRUQLD 10-1 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG POXPELQJ MEP CRQVXOWLQJ EQJLQHHUV A/E ARCHITECT/ENGINEER ABV ABOVE ADA AMERICAN WITH DISABILITIES ACT AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AIA AMERICAN INSTITUTE OF ARCHITECTS ALT ALTERNATE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE AP ACCESS PANEL ARCH ARCHITECT ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AUTO AUTOMATIC AUX AUXILIARY BFP BACKFLOW PREVENTER BLDG BUILDING BTUH BRITISH THERMAL UNITS PER HOUR CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CLG CEILING CO CLEANOUT CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONTR CONTRACTOR COORD COORDINATION CP CIRCULATING PUMP CU.FT CUBIC FEET CW COLD WATER DCV DETECTOR CHECK VALVE DCW DOMESTIC COLD WATER DD DECK DRAIN DDC DIRECT DIGITAL CONTROL DEMO DEMOLITION DEPT DEPARTMENT DET DETAIL DHW DOMESTIC HOT WATER DIM DIMENSION DN DOWN DPX DUPLEX DWG DRAWING EA EACH EFF EFFICIENCY ELEC ELECTRICAL EMER EMERGENCY ENGR ENGINEER EQ EQUAL EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXH EXHAUST EXT EXTERNAL F° FAHRENHEIT FCO FLOOR CLEANOUT FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FF.EL FINISHED FLOOR ELEVATION FHC FIRE HOSE CABINET FHV FIRE HOSE VALVE FIN.FL FINISH FLOOR FIN.GR FINISH GRADE FIXT FIXTURE FP FIRE PROTECTION FS FLOOR SINK FSP FIRE STANDPIPE FT FOOT/FEET FU FIXTURE UNIT FUD FUNNEL DRAIN FUT FUTURE FV FLUSH VALVE FW FILTERED WATER G GAS (LOW PRESSURE) GAL GALLON GC GENERAL CONTRACTOR GI GREASE INTERCEPTOR GPF GALLONS PER FLUSH GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GT GREASE TRAP GW GREASE WASTE GWH GAS WATER HEATER HB HOSE BIBB HDC HANDICAPPED HDR HEADER HLA HIGH LEVEL ALARM HP HORSEPOWER HPG HIGH PRESSURE GAS HR HOUR HS HAND SINK HVAC HEATING, VENTILATING AND AIR CONDITIONING HW HOT WATER HWR HOT WATER RETURN HYD HYDRANT HX EXCHANGER HZ HERTZ ICW INDUSTRIAL COLD WATER IHW INDUSTRIAL HOT WATER IN INCH IND INDUSTRIAL IW INDIRECT WASTE JC JANITORS CLOSET KEC KITCHEN EQUIPMENT CONTRACTOR KW KILOWATT L LAVATORY L/S LITER PER SECOND LAV LAVATORY LBS POUNDS MAX MAXIMUM MBH THOUSAND BTU PER HOUR MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MPG MEDIUM PRESSURE GAS MS MOP SINK MTD MOUNTED NA NOT APPLICABLE NC NORMALLY CLOSED NEMA NATIONAL ELECTRICAL MANUFACT. ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NO NORMALLY OPEN NP NON POTABLE WATER NTS NOT TO SCALE OD OVERFLOW DRAIN OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED OSHA OCCUPATIONAL SAFETY AND HEALTH ACT PAC PRE-ACTION AIR COMPRESSOR PFP PLUMBING AND FIRE PROTECTION PH PHASE PLBG PLUMBING PO PLUGGED OUTLET PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH, GAUGE RD ROOF DRAIN RFI REQUEST FOR INFORMATION RM ROOM RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE SCHED SCHEDULE T&P TEMPERATURE AND PRESSURE RELIEF VALVE TEMP TEMPERATURE THRU THROUGH TYP TYPICAL UBC UNIFORM BUILDING CODE UFC UNIFORM FIRE CODE UL UNDERWRITER'S LABORATORY UON UNLESS OTHERWISE NOTED UPC UNIFORM PLUMBING CODE UTIL UTILITY V VENT VB VACUUM BREAKER VERT VERTICAL VOLT VOLTAGE VTR VENT THRU ROOF W WASTE W/O WITHOUT WC WATER CLOSET WCO WALL CLEANOUT WHA WATER HAMMER ARRESTOR WT WEIGHT WTR WATER FVFU FLUSH VALVE FIXTURE UNITS FTFU FLUSH TANK FIXTURE UNITS DUCT LEGEND APPLICABLE CODES M0.1 PR O J E C T N O T E S , S Y M B O L L I S T & S H E E T IN D E X NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 10 WHVW RR[EXU\ SWUHHW 2 -15  -O% 2-22 WHVW CRYLQD, CDOLIRUQLD 10-1 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG POXPELQJ MEP CRQVXOWLQJ EQJLQHHUV M SHEET INDE; M0.2 ME C H A N I C A L E Q U I P M E N T S C H E D U L E NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 1303 WHVW RR[EXU\ SWUHHW 2 33-15  -O% 23-22 WHVW CRYLQD, CDOLIRUQLD 10-1 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG 3OXPELQJ ME3 CRQVXOWLQJ EQJLQHHUV DESCRIPTION 602 CODE SECTION DUCT MATERIAL INSTALLATION OF DUCTS603 & SMACNA DUCT INSULATION604 SMOKE, FIRE AND CEILING DAMPERS 605 AUTOMATIC SHUT OFFS608 ALL WORK SHALL CONFORM TO THE FOLLOWING 2022 CMC TABLES M0.3 ME C H A N I C A L D E T A I L S NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 1 WHVW RR[EXU\ SWUHHW 2 -15  -O% 2-242 WHVW CRYLQD, CDOLIRUQLD 1-41 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG POXPELQJ MEP CRQVXOWLQJ EQJLQHHUV M1.1 ME C H A N I C A L T I T L E 2 4 C O M P L I A N C E FO R M S NMECHANICAL FLOOR PLAN NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 1 WHVW RR[EXU\ SWUHHW 2 -15  -O% 2-22 WHVW CRYLQD, CDOLIRUQLD 1-1 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG POXPELQJ MEP CRQVXOWLQJ EQJLQHHUV M2.1 ME C H A N I C A L F L O O R P L A N S GENERAL NOTES SHEET INDEXSYMBOLS PLUMBING NOTES 1.ALL EXISTING PIPING SHOWN ARE BASED ON AVAILABLE DRAWINGS AND MAY NOT REFLECT THE ACTUAL INSTALLED EXISTING CONDITION. CONTRACTOR SHALL FIELD VERIFY THE CONNECTION POINTS, DEPTHS, SIZE AND LOCATION OF EXISTING PIPING FOR NEW P.O.C.'S OR DEMOLITION AS REQUIRED PRIOR TO START OF WORK. PLUMBING CONTRACTOR SHALL INFORM THE ARCHITECT OF ANY DISCREPANCIES. 2.ALL WORK SHALL COMPLY WITH CURRENT CITY OF AZUSA CODE REQUIREMENTS, TITLE 24 AND ALL OTHER GOVERNING CODES AND ORDINANCES. 3.ALL VALVES AND WATER HAMMER ARRESTORS LOCATED ABOVE GYPSUM BOARD CEILINGS OR BEHIND WALLS SHALL BE PROVIDED WITH ACCESS PANEL. 4.ALL PIPE PENETRATIONS THROUGH FIRE-RATED WALLS SHALL BE PROVIDED WITH SLEEVES AND FIRE RESISTANT CAULKING. 5.ALL SYMBOLS SHOWN ON THE SYMBOL LIST ARE NOT NECESSARILY USED IN THIS PROJECT. 6.WHERE THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE PROJECT MANUAL OR BUILDING STANDARD SPECIFICATIONS, NOTIFY THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. 7.THE WORK OF THIS PROJECT INVOLVES ALTERATION OF THE BASE BUILDING (PFP) SYSTEMS TO ACHIEVE THE ARRANGEMENT INDICATED ON THE DRAWINGS. THE CONTRACTOR SHALL VISIT THE JOB SITE TO DETERMINE THE EXTENT OF WORK REQUIRED BY THE CONSTRUCTION ACTIVITIES. THE ARCHITECTURAL DRAWINGS SHOW THE EXACT SCOPE OF WORK FOR THIS PROJECT. 8.THESE DRAWINGS INDICATE THE DESIGN INTENT REQUIREMENTS FOR THE (PFP) SYSTEMS, AND EQUIPMENT. DUE TO STRUCTURAL CONDITIONS, ELECTRICAL WIRING OR PIPING INTERFERENCE, OR FOR OTHER REASONS, THE CONTRACTOR MAY DESIRE TO INSTALL THE WORK IN A MANNER DIFFERENT FROM THAT SHOWN TO ACCOMMODATE EXISTING FIELD CONDITIONS. 9.DURING BID, THE CONTRACTOR SHALL EXAMINE THE COMPLETE SET OF DRAWINGS FOR ALL TRADES, AS ISSUED BY THE ARCHITECT AND REVIEW DIMENSIONS SPACE REQUIREMENTS AND POINT OF CONNECTIONS TO ALL EQUIPMENT. MAKE ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICTS WITH THE BUILDING STRUCTURE AND THE WORK OF OTHER TRADES. 10.UNLESS INSTRUCTED OTHERWISE, THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, AND FEES REQUIRED FOR INSTALLATION OF THE (PFP) WORK, INCLUDING THE LOCAL BUILDING DEPARTMENT, DEPARTMENT OF SO CAL EDISON, SOUTHERN CALIFORNIA GAS CO. AND ALL OTHER AGENCIES HAVING JURISDICTION OVER SERVICES TO THIS SITE AND THE BUILDINGS. FURNISH FINAL CERTIFICATE OF INSPECTION OR WRITTEN EVIDENCE OF ACCEPTANCE BY INSPECTION AUTHORITIES FOR ALL WORK INSTALLED. 11.SEE ARCHITECTURAL DRAWINGS FOR EXTENT OF DEMOLITION AND NEW CONSTRUCTION, AND EXACT LOCATION OF FIXTURES, EQUIPMENT, DEVICES, ETC. 12.CONTRACTOR SHALL COORDINATE WITH ALL TRADES TO ENSURE AN UNDERSTANDING OF THE COMPLETE SCOPE OF PROJECT PRIOR TO START OF WORK. 13.BEFORE SUBMITTING PROPOSALS FOR THIS WORK, EACH BIDDER SHALL BECOME FAMILIAR WITH DRAWINGS AND SHALL HAVE EXAMINED THE PREMISES AND BE AWARE OF ALL EXISTING CONDITIONS UNDER WHICH HE WILL BE OBLIGATED TO OPERATE IN PERFORMING HIS CONTRACT. THE CONTRACTOR SHALL NOT BE ENTITLED TO ANY EXTRA COMPENSATION FOR FAILURE TO ALLOW FOR ALL EXISTING CONDITIONS. SUBMITTING OF A BID OR PROPOSAL WILL BE CONSIDERED EVIDENCE OF THE FACT THAT CONTRACTOR IS FULLY AWARE OF THESE CONDITIONS AND IS ABLE TO COMPLETE ALL WORK REQUIRED BY THE DRAWINGS. 14.CONTRACTOR SHALL PROVIDE COMPLETE AS-BUILT DRAWINGS PRIOR TO COMPLETION OF PROJECT FOR REVIEW BY THE ARCHITECT/ENGINEER. PROVIDE AS-BUILT DRAWINGS VIA ELECTRONIC FORMAT (ON CD OR VIA E-MAIL) IN AUTOCAD 2016. 15.IF ANY EQUIPMENT SUBMITTED BY THE CONTRACTOR IS DIFFERENT FROM THAT SPECIFIED, OR REQUIRES CHANGES IN MATERIAL OR LABOR FROM THAT REQUIRED IN THE CONTRACT DOCUMENTS AFFECTING THIS AND/OR OTHER TRADES, SUCH CHANGES SHALL BE SUBMITTED AS SHOP DRAWINGS. SUBMITTAL SHALL INDICATE CREDIT DUE TO OWNER, IF ANY, BECAUSE OF THE CHANGES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PAYMENT OF ALL CHARGES RESULTING FROM ADDITIONS OR CHANGES IN THE WORK OF OTHER TRADES NECESSARY TO ACCOMMODATE THE REQUESTED MODIFICATION. ALL CHANGES SHALL BE SHOWN ON RECORD AND AS-BUILT DRAWINGS. 16.SUBMIT SHOP DRAWINGS AND PRODUCT DATA ACCORDING TO SPECIFICATIONS. A.ALL PLUMBING FIXTURES, EQUIPMENT, PIPING AND MATERIALS SHALL BE LISTED B.ALL PLUMBING FIXTURES THAT PROVIDE WATER FOR HUMAN CONSUMPTION SHALL COMPLY WITH THE CALIFORNINA LEAD FREE LAW(PER SECTION 116875 OF THE CALIFORNIA HEALTH AND SAFETY CODE. C.PUBLIC LAVATORIES SHALL HAVE CONTROLS TO LIMIT THE WATER TEMPERATURE TO 110° F. ENERGY COMMISSION NOTES (CALIFORNIA TITLE 24) 1.ALL WORK SHALL COMPLY WITH THE 2019 CALIFORNIA PLUMBING CODE AND LATEST CITY OF AZUSA REQUIREMENTS AMENDMENTS. 2.PLUMBING CONTRACTOR SHALL PROVIDE A COMPLETE PLUMBING SYSTEM FOR ALL AREAS INCLUDING PLUMBING FIXTURE ROUGH-INS AND ALL UTILITY PIPING. 3.PLUMBING CONTRACTOR SHALL PROVIDE ROUGH-INS, EXTEND ALL PIPING (WASTE, VENT, COLD WATER, HOT WATER, ETC.) TO ALL FIXTURES AND APPLIANCES AS INDICATED ON THE ARCHITECTURAL DRAWINGS. 4.REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF FIXTURES. 5.RUN ALL PLUMBING PIPES AS HIGH AS POSSIBLE TO STRUCTURE AND COORDINATE ROUTING WITH OTHER TRADES. 6.ALL WATER SHUT-OFF VALVES SHALL BE BALL TYPE VALVES. 7.KEEP ALL PIPING CLEAR FROM LOAD BEARING FOOTINGS. 8.ALL PIPE PENETRATIONS THROUGH STRUCTURAL MEMBERS AND WALLS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. 9.DURING CONSTRUCTION, PROVIDE MECHANICAL PLUGS IN OPEN DRAINS TO PREVENT DAMAGE TO LOWER FLOORS. ALL WATER PIPING LOCATED ABOVE CEILING, REQUIRING TEMPORARY OR PERMANENT CAPPED CONNECTIONS, SHALL BE PROVIDED WITH LINE-SIZE SHUT-OFF VALVES. 10.ALL CLEANOUTS SHALL BE ACCESSIBLE AND INSTALLED PER STATE OF CALIFORNIA PLUMBING CODE/UPC SECTION 707 & 719. 11.PROVIDE AND INSTALL ACCESSIBLE WATER HAMMER ARRESTERS OF REQUIRED SIZE AND LOCATION. MANUFACTURER AND MODEL NUMBERS SHALL BE PER SPECIFICATIONS. 12.PROVIDE ACCESS PANELS IN WALLS FOR SHUT-OFF VALVES, TRAP PRIMERS AND WATER HAMMER ARRESTERS. CONTRACTOR IS ADVISED THAT ITEMS REQUIRING ACCESS SHALL NOT BE LOCATED ABOVE THE AREAS OF GYPSUM BOARD CEILING WITHOUT CONSENT OF ARCHITECT. SUBMIT PROPOSED ACCESS PANEL LOCATIONS TO ARCHITECT FOR APPROVAL. 13.ALL FLOOR DRAINS AND FLOOR SINKS SHALL BE PROVIDED WITH CODE-APPROVED ACCESSIBLE TRAP PRIMERS. 14.ALL WATER FAUCETS SHALL BE PROVIDED WITH CODE-APPROVED FLOW RESTRICTORS. 15.ALL VENTS THROUGH ROOF SHALL BE MINIMUM OF THREE FEET VERTICALLY OR TEN FEET HORIZONTALLY FROM AIR CONDITIONING EQUIPMENT FRESH AIR INTAKES, WINDOWS, DOORS OR OTHER OPENINGS. 16.SLOPE OF SANITARY SEWER PIPES SHALL NOT BE LESS THAN 2% UNLESS OTHERWISE INDICATED AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. 17.PROVIDE AND INSTALL CHROME PLATED ANGLE STOPS AT ALL FIXTURES. 18.ALL PIPING TO BE SEISMICALLY BRACED TO PREVENT SWAYING PER STATE OF CALIFORNIA BUILDING CODE. 19.ALL HOSE BIBBS AND JANITORIAL SERVICE SINKS SHALL BE EQUIPPED WITH APPROVED, PROPERLY INSTALLED ATMOSPHERIC TYPE VACUUM BREAKERS. DEVICES SHALL BE ACCESSIBLE FOR TEST AND MAINTENANCE. 20.ROUGH-INS, CONNECTIONS AND TERMINATION OF PLUMBING WORK SHALL BE SEQUENCED IN COORDINATION WITH THE PROJECT SCHEDULE AND THE OWNERS OTHER CONTRACTORS AND VENDORS. 21.A MINIMUM 1/2" CLEARANCE SHALL BE PROVIDED AROUND PIPES AT ALL PENETRATIONS THROUGH WALLS AND ROOF. THE GAP SHALL BE PACKED TIGHTLY WITH LOOSE, LIGHTWEIGHT INSULATION THROUGH NON RATED WALLS, AND APPROVED U.L. LISTED FIRE SAFEING MATERIAL RATED WALLS TO MATCH WALL RATING. 22.CONTRACTOR TO PROVIDE ISOLATION VALVE IN ALL TRAP PRIMER SUPPLY LINE. 23.CONTRACTOR TO INSTALL WALL CLEANOUTS BEHIND ACCESS PANELS. 24.CONTRACTOR TO PROVIDE 1" THERMACELL INSULATION FOR DOMESTIC HOT WATER PIPING. 25.DO NOT INSTALL ANY WATER OR DRAIN PIPING OVER ELECTRICAL OR TELECOM ROOMS. 26.COMPLETE PLUMBING INSTALLATION SHALL COMPLY WITH LEAD FREE REQUIREMENTS AS CALLED FOR ASSEMBLY BILL AB-1953. 27.ALL EQUIPMENT AND FIXTURES INSTALLED SHALL BE IAPMO APPROVED FOR INSTALLATION IN THE CITY OF IRVINE CODES. 28.ALL CONDENSATE DRAIN PIPING SHALL BE INSULATED SIMILAR TO HOT WATER PIPING INSULATION'S MATERIALS AND THICKNESS. 29.HANDICAPPED PLUMBING FIXTURES SHALL BE MOUNTED AT REQUIRED HEIGHTS AND WITH ALL RELATED ACCESSORIES AS REQUIRED BY THE CALIFORNIA OFFICE OF THE STATE ARCHITECT AND AMERICANS WITH DISABILITIES ACT (ADA). ALL FIXTURE TRAPS, PIPING AND VALVES UNDER THE FIXTURE SHALL BE INSULATED WITH A FACTORY PREFORMED INSULATION SIMILAR TO PRO-CAP. 30.CONTRACTOR TO REPLACE ALL EXISTING PIPING, VALVES, FITTINGS, HANGERS, ETC. FOUND TO BE DEFECTIVE, CORRODED, LEAKING, FROZEN AND CLOGGED UP. 31.RAISE/RELOCATE ALL EXISTING PIPING AS REQUIRED TO ACCOMMODATE NEW CEILING, HVAC DUCTS, LIGHTING. 32.CONTRACTOR SHALL X-RAY EXISTING FLOOR SLABS PRIOR TO CORE DRILLING AND OR CUTTING. 1.DOMESTIC WATER HEATERS SHALL MEET THE STATE OF CALIFORNIA ENERGY REQUIREMENTS. 2.ALL HOT WATER SUPPLY PIPING SHALL BE INSULATED FROM THE SOURCE TO THE POINT OF USE PER S.M.M.C. INSULATE ALL FITTINGS, VALVES, STRAINERS, ETC. BY EITHER PREFABRICATION OR BY FABRICATING FITTINGS FROM METERED SEGMENTS OF PIPE INSULATION TO AN EQUAL THICKNESS OF ADJOINING PIPE INSULATION. INSULATION VALUE OF R-6 FOR PIPING 2" AND SMALLER, & R-8 FOR LARGER PIPING. 3.SERVICE WATER HEATING SYSTEM SHALL BE EQUIPPED WITH AUTOMATIC TEMPERATURE CONTROLS CAPABLE OF ADJUSTMENT FROM THE LOWEST TO THE HIGHEST ACCEPTABLE TEMPERATURE SETTING. 4.ALL WATER FAUCETS AND SHOWER HEADS SHALL BE PROVIDED WITH CODE APPROVED FLOW RESTRICTORS. LAVATORY FAUCETS AND SINKS (NOT INCLUDING SERVICE SINK FAUCETS) SHALL MEET THE FLOW REQUIREMENTS OUTLINED IN THE APPLIANCE EFFICIENCY STANDARD. 5.ALL PLUMBING FIXTURES SHALL BE LOW FLOW TYPE AND APPROVED BY THE ENERGY CONSERVATION STANDARDS. 6.WHEN A CIRCULATING HOT WATER SYSTEM IS INSTALLED, IT SHALL BE AQUASTAT CONTROLLED AND HAVE A CONTROL CAPABLE OF AUTOMATICALLY TURNING OFF THE CIRCULATING PUMPS WHEN HOT WATER IS NOT REQUIRED (INDICATED TIME CLOCK). W WASTE PIPING (W) EX.W EXISTING WASTE PIPING (EX.W) SAN SANITARY PIPING (W) EX.SAN EXISTING SANITARY PIPING (EX.SAN) UNDERGROUND DRAINAGE PIPING PIPING CD CONDENSATE DRAIN PIPING (CD) IW INDIRECT WASTE PIPING (IW) V VENT PIPING (V) EX.V EXISTING VENT PIPING (EX.V) DOMESTIC COLD WATER PIPING (CW) EX.CW EXISTING DOMESTIC COLD WATER PIPING (EX.CW) DOMESTIC HOT WATER PIPING (HW) EX.HW EXISTING DOMESTIC HOT WATER PIPING (EX.HW) DOMESTIC HOT WATER RETURN PIPING (HWR) EX.HWR EXISTING DOMESTIC HOT WATER RETURN PIPING (HWR) NPW NON-POTABLE WATER PIPING (NPW) FW FILTERED WATER PIPING (FW) PIPE UP UNLESS OTHERWISE NOTED FITTINGS PIPE DROP UNLESS OTHERWISE NOTED PIPE DROP OR RISE TOP CONNECTION LOW HIGH BOTTOM CONNECTION CLEANOUT (PIPING AT CLG) (CO) CLEANOUT (BURIED PIPING) (FCO) TRAP VENT THROUGH ROOF (VTR) UNION VALVES SHUT-OFF VALVE (SOV) BALANCING VALVE (BV)/GLOBE VALVE (GV) PRESSURE REDUCING VALVE (PRV) CHECK VALVE (CV) OS&Y VALVE GAS COCK EARTHQUAKE VALVE T&P VALVE VALVED & CAPPED OUTLET TRAP PRIMER VALVE BACKFLOW PREVENTER STRAINER FLOOR DRAIN/ROOF DRAIN FIXTURES FLOOR SINK FLOOR SINK - HALF GRATE OVERFLOW DRAIN ROOF RECEPTOR HOSE BIBB PRESSURE GAUGE WATER FLOW SWITCH EQUIPMENT IN-LINE FILTER INSTANTANEOUS ELECTRIC WATER HEATER EWH ELECTRIC STORAGE TYPE WATER HEATER CIRCULATOR PUMP ANNOTATION POINT OF CONNECTION (POC) SQUARE FOOT (SQ.FT) DIAMETER (DIA) REVISION TAG SHEET NUMBER NUMBER DETAIL DETAIL DESIGNATION # EQUIPMENT DESCRIPTION NUMBER EQUIPMENT EQUIPMENT DESIGNATION F FIRE LINE (F) SPR SPRINKLER PIPING (SPR) (WET-PIPE) SP.DR SPRINKLER DRAIN (SP.DR) CSP COMBINATION STANDPIPE SYSTEM (CSP) PA PREACTION SPRINKLER SYSTEM (PA) ABBREVIATIONS -A- A/E ARCHITECT/ENGINEER ABV ABOVE ACC.DR ACCESS DOORAD AREA DRAIN ADA AMERICAN WITH DISABILITIES ACT AFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT AIA AMERICAN INSTITUTE OF ARCHITECTS ALT ALTERNATE ANSI AMERICAN NATIONAL STANDARDS INSTITUTE AP ACCESS PANELARCH ARCHITECT ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERSASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AUTO AUTOMATIC AUX AUXILIARY -B- BEL, BLW BELOWBFF BELOW FINISHED FLOOR BFP BACKFLOW PREVENTER BLDG BUILDINGBTUH BRITISH THERMAL UNITS PER HOUR -C- CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTECI CAST IRON CLG CEILING CO CLEANOUTCONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTIONCONTR CONTRACTOR COORD COORDINATION CP CIRCULATING PUMPCU.FT CUBIC FEET CW COLD WATER -D- DCW DOMESTIC COLD WATER DD DECK DRAIN DDC DIRECT DIGITAL CONTROL DEMO DEMOLITION DEPT DEPARTMENT DET DETAILDF DRINKING FOUNTAIN DFU DRAIN FIXTURE UNIT DHW DOMESTIC HOT WATER DI DEIONIZED WATER DIM DIMENSION DN DOWN DR DRAIN DW DISHWASHERDWG DRAWING -E- EA EACH EFF EFFICIENCY EL ELEVATION ELEC ELECTRICAL EMER EMERGENCY ENGR ENGINEER EQ EQUAL EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXH EXHAUST EXT EXTERNAL -F- ° F FAHRENHEIT FCO FLOOR CLEANOUT FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FF.EL FINISHED FLOOR ELEVATION FHC FIRE HOSE CABINET FHV FIRE HOSE VALVE FIN.FL FINISH FLOOR FIN.GR FINISH GRADE FIXT FIXTURE FP FIRE PROTECTION FS FLOOR SINKFSP FIRE STANDPIPE FT FOOT/FEET FU FIXTURE UNITFUD FUNNEL DRAIN FUT FUTURE FV FLUSH VALVE FW FILTERED WATER -G- G GAS (LOW PRESSURE) GAL GALLON GC GENERAL CONTRACTORGI GREASE INTERCEPTOR GPF GALLONS PER FLUSH GPH GALLONS PER HOUR GPM GALLONS PER MINUTE GT GREASE TRAP GW GREASE WASTEGWH GAS WATER HEATER -H- HB HOSE BIBB HDC HANDICAPPED HDR HEADER HP HORSEPOWER HR HOUR HS HAND SINK HV HOSE VALVE HVAC HEATING, VENTILATING AND AIR CONDITIONING HW HOT WATER HWR HOT WATER RETURN HYD HYDRANT HX EXCHANGER HZ HERTZ -I- ICW INDUSTRIAL COLD WATER IE INVERT ELEVATION IHW INDUSTRIAL HOT WATER IN INCH IND INDUSTRIAL IW INDIRECT WASTE -J- JC JANITORS CLOSET -K- KEC KITCHEN EQUIPMENT CONTRACTOR KW KILOWATT -L- L LAVATORY L/S LITER PER SECOND LAP LOCAL ALARM PANEL LAV LAVATORYLBS POUNDS LD LEAK DETECTION -M- MAX MAXIMUM MBH THOUSAND BTU PER HOUR MCC MOTOR CONTROL CENTER MECH MECHANICAL MFR MANUFACTURER MH MANHOLE MIN MINIMUM MPG MEDIUM PRESSURE GAS MS MOP SINK MTD MOUNTED -N- N NORTH NA NOT APPLICABLENC NORMALLY CLOSED NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA NATIONAL FIRE PROTECTION ASSOCIATIONNIC NOT IN CONTRACT NO NORMALLY OPEN NP NON POTABLE WATER NTS NOT TO SCALE -O- OD OVERFLOW DRAIN OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED OSHA OCCUPATIONAL SAFETY AND HEALTH ACT -P- PAC PRE-ACTION AIR COMPRESSOR PFP PLUMBING AND FIRE PROTECTIONPH PHASE PLBG PLUMBING PO PLUGGED OUTLET PRESS PRESSURE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH, GAUGE -R- R RADIUSRD ROOF DRAIN REF REFERENCE REQ'D REQUIREDRFI REQUEST FOR INFORMATION RM ROOM RO REVERSE OSMOSIS RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE RR ROOF RECEPTOR -S- S SINK SAN SANITARY SCFM STANDARD CUBIC FEET PER MINUTESCHED SCHEDULE SD STORM DRAIN SED SEWAGE EJECTOR DISCHARGESH SHOWER SH.DR SHOWER DRAIN SK SINKSOV SHUT-OFF VALVE SPEC SPECIFICATION SPK SPRINKLER SS SERVICE SINK SSD SUB-SOIL DRAINAGE STRUCT STRUCTURAL -T- T&P TEMPERATURE AND PRESSURE RELIEF VALVE TD TRENCH DRAIN TEMP TEMPERATURE THRU THROUGH TS TAMPER SWITCH TYP TYPICAL -U- UBC UNIFORM BUILDING CODE UFC UNIFORM FIRE CODE UL UNDERWRITER'S LABORATORY UON UNLESS OTHERWISE NOTED UPC UNIFORM PLUMBING CODE UR URINAL USSG UNITED STATES STANDARD GAUGE UTIL UTILITY -V-V VENTVB VACUUM BREAKER VERT VERTICAL VO VALVED OUTLETVOL VOLUME VOLT VOLTAGE VTR VENT THRU ROOF -W- W WASTE W/O WITHOUT WC WATER CLOSET WCO WALL CLEANOUTWF WATER FILTER WH WALL HYDRANT WHA WATER HAMMER ARRESTORWM WATER METER WP WORKING PRESSURE WT WEIGHTWTR WATER CALIFORNIA GREEN NOTES 1.CONTRACTOR SHALL PROVIDE TESTING AND BALANCING REQUIREMENTS PER SECTION 5.410.4 OF THE CALIFORNIA GREEN BUILDING CODE. 2.MATERIALS USED SHALL HAVE VOC LIMITS IN COMPLIANCE WITH TABLE 5.504.4.1 OF THE CALIFORNIA GREEN BUILDING CODE. 3.DESIGN SHALL ADOPT MANDATORY MEASURES FOR WATER EFFICIENCY AND CONSERVATION PER CHAPTER 5 DIVISION 5.3 OF THE CALIFORNIA GREEN BUILDING CODE AND THE CITY OF LA MIRADA WATER CONSERVATION STANDARDS. 4.FLOW RATES ARE TO COMPLY WITH TABLE 5.303.2.3 TO OBTAIN 20% REDUCTION IN THE BASELINE FLOW RATE. 5.PROVIDE SEPARATE SUB METERS OR METERING DEVICES IF THE BUILDING IS IN EXCESS OF 50,000 SQ. FT. A.SPECIFIC REQUIREMENTS ARE TO BE FOUND IN SECTION 5.303.1.1. 7.PROVIDE SEPARATE SUB METERS OR METERING DEVICES FOR ANY BUILDING OR SPACE WITHIN A BUILDING THAT IS PROJECTED TO CONSUME MORE THAN 1000 GAL/DAY. 8.DOMESTIC WATER SUB-METERS SHALL BE PROVIDED BY TENANT. 9.FIELD QUALITY CONTROL FOR SERVICE WATER HEATERS: A.MANUFACTURER'S FIELD SERVICE: ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT, TEST, AND ADJUST FIELD-ASSEMBLED COMPONENTS AND EQUIPMENT INSTALLATION, INCLUDING CONNECTIONS, AND TO ASSIST IN FIELD TESTING. REPORT RESULTS IN WRITING. B.PERFORM THE FOLLOWING FIELD TESTS AND INSPECTIONS AND PREPARE TEST REPORTS: a.LEAK TEST: AFTER INSTALLATION, TEST FOR LEAKS. REPAIR LEAKS AND RETEST UNTIL NO LEAKS EXIST. b.OPERATIONAL TEST: AFTER ELECTRICAL CIRCUITRY HAS BEEN ENERGIZED, CONFIRM PROPER OPERATION. c.TEST AND ADJUST CONTROLS AND SAFETIES. REPLACE DAMAGED AND MALFUNCTIONING CONTROLS AND EQUIPMENT. C.REMOVE AND REPLACE WATER HEATERS THAT DO NOT PASS TESTS AND INSPECTIONS AND RETEST AS SPECIFIED ABOVE. 9.DEMONSTRATION FOR ELECTRIC WATER HEATERS: A.ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN INSTANTANEOUS ELECTRIC WATER HEATERS. PLAN CHECK NOTES 1.ALL FIXTURES, EQUIPMENT, PIPING, AND MATERIALS SHALL BE LISTED. (2022 CPC 301.1) 2.ALL PLUMBING FIXTURES SHALL MEET THE FLOW REQUIREMENTS SPECIFIED I. (2022 CPC 407.2). 3.ALL FAUCETS IN PUBLIC RESTROOMS SHALL BE SELF CLOSING OR SELF CLOSING METERING FAUCETS (2022 CPC 407.4). 4.PUBLIC LAVATORIES SHALL HAVE CONTROLS TO LIMIT THE WATER TEMPERATURE TO 120° F (2022 CPC 407.3). 5.WATER PIPE AND FITTINGS WITH A LEAD CONTENT WHICH EXCEEDS 0.25% SHALL BE PROHIBITED IN SYSTEMS CONVEYING POTABLE WATER. (2022 CPC 604.2). 6.SHOWERS, IF ANY, SHALL BE PROVIDED WITH INDIVIDUAL TEMPERING VALVES. (2022 CPC 408.3). FVFU FLUSH VALVE FIXTURE UNITS FTFU FLUSH TANK FIXTURE UNITS P0.1 PLUMBING LEGENDS AND GENERAL NOTES P0.2 PLUMBING FIXTURE SCHEDULES P0.3 PLUMBING DETAILS P1.0 PLUMBING DEMOLITION FLOOR PLAN P1.1 PLUMBING FLOOR PLAN - DOMESTIC COLD/HOT WATER/ WASTE P1.2 PLUMBING FLOOR PLAN - O2 & N2O REMOVE PIPING OR PLUMBING FIXTURE CA COMPRESSED AIR LINE (CA) VAC VACUUM LINE (VAC) PLUMBING SCOPE OF WORK 1. TENANT IMPROVEMENT FOR NEW DENTAL OFFICE. 2. PROVIDE NEW SANITARY SEWER AND VENT CONNECTIONS TO NEW FIXTURES FROM EXISTING NEARBY PIPING. 3. PROVIDE NEW DOMESTIC COLD AND HOT WATER CONNECTIONS TO NEW FIXTURES FROM EXISTING NEARBY PIPING. NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 1 WHVW RR[EXU\ SWUHHW 2 -15  -O% 2-22 WHVW CRYLQD, CDOLIRUQLD 1-1 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG 3OXPELQJ ME3 CRQVXOWLQJ EQJLQHHUV PROJECT NOTES, SYMBOL LIST & SHEET INDEX P 0.1 CAPACITYMARKMAKE & MODEL NO. RECIRCULATION PUMP SCHEDULE REMARKS 3 GPM 120/1/60 120°F HOT WATER; PROVIDE WITH5 FT. HD.BELL & GOSSETT SSF-9U/LW, STAINLESS STEEL CIRCULATOR, 41 W, 0.4 AMP TMV SET AT 110°. CONNECTIONS IN OUT 3/4"3/4" VOLTAGE/ HP TOTAL HD. (PSI) -CP-1 FV COLD WATER MAXIMUM F.U. ALLOWABLE SIZE 3/4" 1" 2.80 PSI/100' TYPE "L" PIPE 1 1/4" 1 1/2" FT PIPE SIZING CHART GPM FPS 6.0 8.0 -7 18-13.0 32-21.0 631834 8.0 8.0 8.0 1/2"2.2 8.0 -1 COLD WATER MAIN AND METER CALCULATIONS* 3. ESTIMATION OF AVAILABLE PRESSURE FOR DISTRIBUTION A.AVAILABLE STREET PRESSURE: MIN. 43 PSI B.(E)3/4" WATER METER PRESSURE DROP: 7 PSI C. WILKINS 975XL - 1" BACKFLOW PREVENTER 13 PSI D.BUILDING STATIC PRESSURE DROP: 3.5 PSI (15FT) E.MIN. REQUIRED RESIDUAL PRESSURE: (TANK ONLY) 15 PSI AVAILABLE PRESSURE FOR DISTRIBUTION: 4.5 PSI MAX. ALLOWABLE PRESSURE DROP AT PIPE: (4.5 PSI / 95 FT) X 100 FT = 4.3 PSI / 100 FT 2. TOTAL ESTIMATED DEVELOPED PIPE LENGTH:95 FT 4. ESTIMATE MINIMUM REQUIRED WATER MAIN TO SATISFY ALL OF THE FOLLOWING DESIGN CONDITIONS: A.CARRY TOTAL ESTIMATED GPM: 15 GPM OR (22.5 F.U) B.COLD WATER VELOCITY <= 8 FT/S B.HOT WATER VELOCITY <= 5 FT/S MIN.REQUIRED SIZE OF MAIN: 1"Ø MAIN < (E)1-1/2"Ø CW 1.PROPOSED FIXTURE UNIT: 22.5 F.U. (15 GPM) WATER SUPPLY SYSTEM: DISTANCE TO MOST REMOTE FIXTURE = 80 FT. MIN. REQUIRED SIZE OF MAIN: 1"Ø MAIN < (E)1-1/2"Ø CW FIXTURE QTY SANITARY WASTE EACH TOTALTYPE PLUMBING FIXTURE UNIT (FU) CALCULATION TAG WATER EACH TOTALQTY TAG FIXTURE WASTE TRAP VENT CW HW MINIMUM PLUMBING FIXTURE BRANCH PIPE SIZE REMARK PROVIDE WATER HAMMER ARRESTER FOR EACH FLUSH VALVE FIXTURE. PROVIDE THERMAL MIXING VALVE AND SET HOT WATER TEMPERATURE NO HIGHER THAN 120°F. REMARKS 1.PIPE SIZES SHOWN MAY NOT BE NECESSARY THE FIXTURE CONNECTION SIZE. SEE FINAL PRODUCT MANUFACTURER RECOMMENDED PIPING CONNECTION SIZES PRIOR TO INSTALL. PROVIDE REDUCER BETWEEN BRANCH LINE AND CONNECTION AS REQUIRED. 2.UNDERGROUND VENT PIPE SHALL BE 1"Ø LARGER THAN SCHEDULED SIZE. 3.UNDERGROUND COLD WATER PIPE SHALL BE TYPE-K LEAD FREE COPPER PIPE. GENERAL NOTES HAND SINKL WC WATER CLOSET 4"2"2"--3/4" 162.0 16HAND SINK 8SK/ HS 2.08 TP TRAP PRIMER --------1/2" 2"1-1/2"1-1/2"3/4"3/4" ITEM PIPE MATERIAL SCHEDULE LOCATION DOMESTIC COLD WATER PIPE SPECIFICATIONS TYPE L COPPER BELOW GRADE ABOVE GRADE SANITARY AND VENT PIPE ABOVE GRADE CONDENSATE ABOVE AND BELOW GRADE TYPE K COPPER TYPE M COPPER DOMESTIC COLD WATER PIPE SANITARY AND VENT PIPE BELOW GRADE SCH. 40 PVC SCHEDULE SHOWN FOR QUICK REFERENCE ONLY. PROVIDE AND INSTALL PER APPROVAL FROM THE JURISDICTION HAVING AUTHORITY. ALL WASTE, CONDENSATE WASTE AND WATER PIPING SHALL COMPLY WITH TABLE 701.2 AND 604.1. ITEM PIPING INSULATION SCHEDULE LOCATION ALL ALL HOT WATER SUPPLY (PIPE<1"Ø) HOT WATER SUPPLY (1"Ø TO < 1-1/2"Ø) INSULATION TYPE THERMACELL MIN. R-VALVE MIN. THICKNESS REMARK -- -- 1" 1.5" REMARKS: ALL INSULATION OR ACCOUSTICAL LINING SHALL HAVE SMOKE SPREAD INDEX LESS THAN 50 AND FLAME SPREAD INDEX LESS THAN 25. THERMACELL ALLCONDENSATE PIPE THERMACELL --0.5" ALLHOT WATER SUPPLY (1-1/2"Ø TO 4"Ø)THERMACELL --1.5" TOTAL FU 2522.5 2.0----FLOOR SINK 1FS 2.01 --HOSE BIBB 0HB --- --HUB DRAIN -HD --- 2.52.5 2.5WATER CLOSET 1WC 2.51 THE INSULATION WALL THICKNESS FOR PIPE SIZES UP TO 2" IN DIAMETER SHALL BE NOT LESS THAN THE DIAMETER OF THE PIPE, AND SHALL NOT BE LESS THAN 2" FOR PIPE SIZE 2" OR MORE IN DIAMETER. MAX: 53 MIN: 43 TAG FIXTURE DESCRIPTIONMAX. WATER USAGE PLUMBING FIXTURE SCHEDULE HAND SINK 0.4 GPM 0.4 GPMHAND SINK "ELKAY" LUSTERTONE CLASSIC MODEL #LRAD252155 SINGLE BOWL DROP-IN, STAINLESS STEEL, ADA SINK. PROVIDE WITH "MOEN" ALIGN #5965 SERIES FAUCET, FLOW RESTRICTOR AT 0.4 GPM. INSTALL "PROFLO" MODEL #PFSCPT1SWH ADA SOFT TRAP COVER. "KOHLER" VERTICYL RECTANGLE, MODEL #K-2882, UNDERMOUNT BATHROOM SINK, WHITE FINISH. PROVIDE "DELTA" GALEON BATHROOM FAUCET MODEL #571-MPU-DST, MATTE BLACK FINISH, WITH FLOW RESTRICTOR AT 0.4 GPM. WATER CLOSET 1.0 GPF "TOTO" ULTRAMAX II 1G ONE-PIECE TOILET MODEL #MS604114CUFG, #01 COTTON FINISH. PROVIDE COMMERCIAL HEAVY-DUTY PLASTIC TOILET SEAT BY "OLSONITE" MODEL #10CT. LAVATORY 0.4 GPM "NAMEEK'S" MONA, CERASTYLE MODEL #064200-U WALL MOUNTED BATHROOM SINK. PROVIDE "DELTA" GALEON BATHROOM FAUCET MODEL #571-MPU-DST, MATTE BLACK FINISH, WITH FLOW RESTRICTOR AT 0.4 GPM. INSTALL "PROFLO" MODEL #PFSCPT1SWH ADA SOFT TRAP COVER. N/AEMERGENCY EYEWASH "GUARDIAN" MODEL #G5022BP EYEWASH/DRENCH HOSE UNIT, DECK MOUNTED, WITH BACKFLOW PREVENTER. PLUMBING EQUIPMENT SCHEDULE TAG DESCRIPTION ELECTRIC WATER HEATER. A.O. SMITH DSE-30: 30 GALS WITH CIRCULATING PUMP. 208/1/60, 6 KW INPUT, 38 GPH RECOVERY, 400 LBS OPERATING MOP SINK FIAT PRODUCTS "TERRAZZO" #TSB3010 12" DEPTH WITH 6" DROP FRONT, 24" X 24" SQUARE MOP SERVICE BASIN. PROVIDE WITH HOSE BIBB AND VACUUM BREAKER.N/A FLOOR SINK N/A CECO #1008 12" ROUND FLOOR SINK WITH TRAP PRIMER CONNECTION AS REQUIRED. FOOD WASTE DISPOSER N/A INSINKERATOR "PRO SERIES" #750, 3/4 HP, 120 VOLTS, 60 HZ, 1725 RPM. FOR SINK AT STAFF LOUNGE. SCH. 40 PVC WC-1 L-1 S-2 HS-1 EEW GD-1 WH-1 MS-1 FS-1 1.01.0 1.0LAVATORY1LV 1.01 ---- ---- 2.52.5 2.5CLOTHES WASH.1WASHER 2.51 WASHER BOX N/A WATTS A2C-M1 INTELLIFLOW WASHER BOX WITH LEAK SENSOR.WB-1 ICE MAKER BOX N/AIMB-1 HS/ S HAND SINKS 2"2"1-1/2"3/4"3/4" MS MOP SINK 3"2"2"3/4"3/4" ET 1 EXPANSION TANK SCHEDULE EXPANSION TANK CALCULATION WATER HEATER CALCULATION NE W D E N T A L S U I T E )O R AM < T R A N , D  D  S  12 1 5 W E S T H U N T I N G T O N D R I 9 E - A R C A D I A , C A 1303 West Roxbury Street (626) 337-1965 / JOB #23-2462 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers PLUMBING FIXTURE SCHEDULE & CALCULATIONS P 0.2 WATER HEATER PLATFORM DETAIL FLOOR DRAIN / SINK TRAP PRIMER DETAIL EXPANSION TANK MOUNTING DETAIL TYPICAL TRAPEZE PIPE HANGER AND SPACING DETAIL 21 5 6 8 3 4 10 11 ₂ ₂O ₂ ₂O NOTES (PER NFPA 99 SECTION 5.1.11.1): 1.AT INTERVALS OF NOT MORE THAN 20 FEET. 2.AT LEAST ONCE IN OR ABOVE EVERY ROOM. 3.ON BOTH SIDES OF WALL OR PARTITIONS PENETRATED BY THE PIPING. 4.AT LEAST ONCE IN EVERY STORY HEIGHT TRAVERSED BY RISERS. PIPE LABEL COLOR CODE (PER NFPA 99 TABLE 5.1.11): NITROGEN OXIDE ( ) - BLUE / WHITE OXYGEN ( ) - GREEN / WHITE OR WHITE / GREEN ₂O ₂ NITROUS OXIDE AND OXYGEN PIPE LABELING BACKFLOW PREVENTER DETAIL ~ ~ G ~ ~ 1E W ' E 1 7 $ / S 8 , 7 E )O R $M < 7 R $ 1 , '  '  S  12 1 5 W E S 7 + 8 1 7 , 1 G 7 O 1 ' R , 9 E - $ R C $ ' , $ , C $ 1303 West Roxbury Street (626) 337-1965 / JOB #23-2462 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers PLUMBING DETAILS P 0.3 DEMOLITION PLAN N NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 1 WHVW RR[EXU\ SWUHHW 2 -15  -O% 2-22 WHVW CRYLQD, CDOLIRUQLD 1-1 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG POXPELQJ MEP CRQVXOWLQJ EQJLQHHUV PLUMBING DEMOLITION FLOOR PLAN P 1.0 KEYNOTES GENERAL NOTE: EWH WC-1 HS-1 S-2 GD-1 L-1 WH-1 CP-1 HS-1 HS-1 HS-1 HS-1 S-2 EEW S-2 WC-1 S-2 GD-1 L-1 S-2 EEW S-2 WB WH-1 MS-1 HS-1 HS-1 HS-1 HS-1 HS-1 LAB Sterilization Private Office Staff Lounge Treatment Room 5 Treatment Room 4 Treatment Room 3 Treatment Room 2 Treatment Room 1 W/D Waiting Reception 2 Business Manager CBCT LAB Sterilization Private Office Staff Lounge Treatment Room 5 Treatment Room 4 Treatment Room 3 Treatment Room 2 Treatment Room 1 Waiting Reception 2 Business Manager CBCT MS-1 PLUMBING FLOOR PLAN - COLD/HOT WATER SCALE: 1/4" = 1'-0" 1 P 2.1 PLUMBING FLOOR PLAN - WASTE/VENT SCALE: 1/4" = 1'-0" 1 P 1.1 WB-1 IM-1 NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 1 WHVW RR[EXU\ SWUHHW 2 -15  -O% 2-22 WHVW CRYLQD, CDOLIRUQLD 1-1 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG 3OXPELQJ ME3 CRQVXOWLQJ EQJLQHHUV PLUMBING FLOOR PLANS - WASTE/VENT & COLD/HOT WATER P 1.1 KEYNOTES LAB Sterilization Private Office Staff Lounge Waiting Reception 2 Business Manager PLUMBING FLOOR PLAN - VACUUM & COMPRESSED AIR SCALE: 1/4" = 1'-0" 1 P 3.1 NE W D E N T A L S U I T E FO R AM Y T R A N , D . D . S . 12 1 5 W E S T H U N T I N G T O N D R I V E - A R C A D I A , C A 1 WHVW RR[EXU\ SWUHHW 2 -15  -O% 2-22 WHVW CRYLQD, CDOLIRUQLD 1-1 MY Engineering, Inc. MHFKDQLFDO, EOHFWULFDO DQG 3OXPELQJ ME3 CRQVXOWLQJ EQJLQHHUV PLUMBING FLOOR PLANS - VACUUM/COMPRESSED AIR & MEDICAL GAS P 1.2 KEYNOTES