HomeMy WebLinkAbout123 W Huntington Dr - 2024 - Hilton Hotel Tie Downs16 0 2 3 S w i n g l e y R i d g e R o a d , C h e s t e r f i e l d , M O 6 3 0 1 7 T: ( 9 5 1 ) 2 6 8 - 3 6 7 0 F : ( 9 5 1 ) 2 7 3 - 0 0 4 0 HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . , A R C A D I A , C A GE N E R I C S U B M I T T A L REVISION DATE DESCRIPTION 1 2024-01-11 UPDATE PLANS Z4 PROJECT No.: 2300954 SCALE: NOT TO SCALE ISSUE DATE (YYYY-MM-DD): 2023-11-23 DRAWN BY: HUONG CHECKED BY: LW SHEET No.: PR O J E C T N A M E : SH E E T N A M E : HI L T O N A R C A D I A PR O J E C T N A M E : - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SYSTEM DESCRIPTION MiTek Z4 IS A CONTINUOUS ROD TIE-DOWN SYSTEM USED IN WOOD FRAMED SHEAR WALLS CONSISTING OF CINCH NUT (CNX OR CNXO) DEVICES, STEEL ALL THREAD ROD (ATR), AND STEEL BEARING PLATE WASHERS (BPW). THE SYSTEM WILL RESIST SHEAR WALL UPLIFT WHILE COMPENSATING FOR SETTLEMENT, SHRINKAGE, AND COMPRESSION LOADING BY THE CONTINUAL DOWNWARD ACTUATION OF THE CNX DEVICES AS RECOGNIZED IN LA CITY RR 25623 AND ICC (ESR 2190) REPORTS. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - GENERAL NOTES 1.ENGINEER OF RECORD (EOR) A.EOR SHALL VERIFY ALL CODE REQUIRED LOAD PARAMETERS AND LOAD TRANSFERS TO FOUNDATION. EOR'S APPROVAL OF THE ATTACHED Z4 TIE-DOWN SYSTEM DESIGNS ARE ONLY FOR VERIFICATION THAT THE LOAD VALUES (DEMANDS) USED BY MiTek MEET THE EOR’S DESIGN INTENT AND THAT THE SYSTEM DETAILING SHOWN ON THESE SHOP DRAWINGS ARE IN GENERAL CONFORMANCE WITH THE EOR STRUCTURAL PLANS. 2.CINCH NUT (CNX/CNXO) - SEE DETAIL 1 A.THE Z4 CINCH NUT IS A SHRINKAGE COMPENSATION DEVICE THAT CONNECTS THE WOOD FRAMING TO THE Z4 ROD TIE-DOWN SYSTEM. WHEN THE WOOD FRAMING SHRINKS OR SETTLES, THE CINCH NUT RATCHETS DOWN THE THREADS OF THE Z4 ROD SYSTEM TO PROVIDE PERPETUAL SHRINKAGE COMPENSATION. B.CINCH NUT IS IN COMPLIANCE WITH IBC 2009, 2012, 2018, CBC 2010, 2013, 2016, 2019 LABC 2011, 2014, 2017, 2020. TESTING OF THE CNX/CNXO IS IN ACCORDANCE WITH ICC-ES AC316. RESEARCH REPORT: COLA RR 25623, ICC-ES REPORT ESR-2190. C.CINCH NUTS USED IN THE CONTINUOUS TIE DOWN SYSTEM ATTACH TO THE WOOD WITH (2) MiTek WS-3 SCREWS OR (2) ¼" LAG SCREWS WITH MINIMUM THREAD INTO WOOD PENETRATION OF 1". D.CINCH NUT (CNX) AND CINCH NUT OMEGA (CNXO) MODELS ARE INTERCHANGEABLE. 3.BEARING PLATE WASHER (BPW) - SEE DETAIL 2 A.Z4 BEARING PLATE WASHERS ARE PAINTED DIFFERENT COLORS TO VISUALLY DIFFERENTIATE LOAD CAPACITIES AND IMPROVE INSTALLATION ACCURACY. B.Z4 BEARING PLATE WASHERS ARE MANUFACTURED WITH STEEL MEETING ASTM A36, GB Q235, OR EQUIVALENT SPECIFICATIONS. C.Z4 BEARING PLATE WASHERS ARE REQUIRED TO BE INSTALLED TIGHT AGAINST THE WOOD TOP PLATE MEMBER. 4.COUPLER (CPL) NUT - SEE DETAIL 3 A.SIGHT HOLES ARE PROVIDED WITH Z4 COUPLER NUTS TO ENSURE PROPER ROD INSTALLATION. B.CONTRACTOR TO VERIFY COUPLERS ARE THREADED HALF WAY INTO COUPLER FROM EACH SIDE. C.REDUCING COUPLER MAY BE REQUIRED AT FOUNDATION OR FLOOR TO FLOOR CONNECTIONS. D.REDUCING COUPLERS SHOULD HAVE THE LARGER DIAMETER ROD FULLY SEATED FIRST, BEFORE TIGHTENING THE SMALLER DIAMETER ROD. E.STANDARD (STD) COUPLERS CONFORM TO ASTM A-563 GRADE A, SAE GRADE 2. F.MID STRENGTH (MS) COUPLERS CONFORM TO ASTM A-563 GRADE C OR SAE GRADE 5 AND ARE DIFFERENTIATED WITH A SINGLE "SAW CUT" MARKING AS INDICATED IN DETAIL 3. G.HIGH STRENGTH (HS) COUPLERS CONFORM TO ASTM A-563 GRADE DH, ASTM A194-2H, OR SAE GRADE 8 AND ARE DIFFERENTIATED WITH A DOUBLE "SAW CUT" MARKING AS INDICATED IN DETAIL 3. 5.ALL THREAD ROD (ATR) - SEE DETAIL 4 & 6 A.Z4 USES STANDARD GRADE AND HIGH STRENGTH ALL THREAD ROD (ATR). STANDARD GRADE ROD CONFORMS WITH ASTM A36. HIGH STRENGTH ROD CONFORMS WITH ASTM A193-B7 AND IS IDENTIFIED BY RED PAINT ON THE ENDS AND CENTER WITH A STAMP LOCATED EITHER AT THE ENDS OR THE CENTER OF THE ROD. B.Z4 USES UNIFORM NATIONAL COARSE (UNC) THREADS FOR THE ROD. C.THREADED ROD INSTALLATION AT BOTTOM PLATE AND FLOOR FRAMING SHOULD USE OVERSIZE HOLES PER DETAIL 4 & 9. HOLES IN THE FLOOR FRAMING THAT ARE NOT OVERSIZED CAN BIND AND BOW THE ROD AS THE BUILDING SETTLES. D.MAXIMUM OUT OF PLUMB FOR ROD IS 2" FOR EVERY 100" OF FLOOR HEIGHT. (SEE DETAIL 6) E.1ST FLOOR ROD CAN BE A LARGER DIAMETER THAN THE FOUNDATION ANCHOR AS THE DESIGN MAY BE CONTROLLED BY ELONGATION UNDER TENSION WHILE THE FOUNDATION ANCHOR MAY BE DESIGNED FOR TENSION ONLY. 6.FOUNDATION ANCHOR A.ANCHOR BOLT SHALL BE A MIN OF 8 INCHES TO A MAX OF 12 INCHES ABOVE CONCRETE U.N.O. ON TIE-DOWN ELEVATIONS. B.ACTUAL EXTENSION ABOVE CONCRETE SHALL BE VERIFIED PRIOR TO SHIPPING Z4 TIE-DOWN SYSTEM MATERIALS. 7.COMPRESSION POSTS - SEE DETAIL 7 & 8 SCOPE OF WORK 1.WHEN APPLICABLE, Z4 TIE-DOWN SYSTEM LAYOUT PLANS (TDLP) ARE PROVIDED TO COORDINATE THE RUN-TYPE NAMES INDICATED ON SHEET(S) Z4-02 WITH THE CORRESPONDING RUN-TYPE NAMES INDICATED ON THE STRUCTURAL DOCUMENTS. SEE ATTACHED TDLP SHEETS. 2.Z4 TIE-DOWN SYSTEM PROVIDED STARTS FROM THE COUPLER AT THE TOP OF THE EMBEDDED ANCHOR AND ABOVE, U.N.O. 3.BUILDING CODE: CBC2019 4.JURISDICTION: CITY OF ARCADIA 5.SHEETS Z4-01 TO Z4-02 REPLACE THE ORIGINAL TIE-DOWN SYSTEM SPECIFIED ON SHEET(S) S6.2, S8.2, S8.3 OF THE STRUCTURAL DOCUMENTS (DATED 2023-11-21) WITH THE MiTek Z4 TIE-DOWN SYSTEM DESCRIBED BELOW. 6.FIRE-RETARDANT TREATED (FRT) LUMBER: REQUIRED AS SHOWN WITHIN ARCHITECTURAL AND/OR STRUCTURAL DOCUMENTS. RUN-TYPES DESIGNED FOR FRT ARE INDICATED WITH (FRT) IN THE RUN-TYPE NAME AS SHOWN WITHIN THE Z4 ELEVATIONS. SHOP DRAWINGS DISCLAIMER 1.THESE SHOP DRAWINGS PROVIDE GENERAL CONFORMANCE WITH THE ENGINEER/ARCHITECT OF RECORD'S PROJECT DRAWINGS. DETAILS SHOWN HEREIN WERE PREPARED TO ACCOMMODATE THE PROJECT DRAWINGS. IN THE EVENT OF A CONFLICT BETWEEN THESE SHOP DRAWINGS AND THE PROJECT DRAWINGS, THE PROJECT DRAWINGS CONTROL. 2.MiTek DID NOT PARTICIPATE IN THE PREPARATION OR REVIEW OF THE PROJECT DESIGN OR DRAWINGS, THEREBY MiTek’S LIABILITY IS LIMITED TO THE DESIGN OF THE Z4 COMPONENTS AND THAT THE COMBINED COMPONENTS, AS SHOWN ON THE SHOP DRAWINGS, MEET APPLICABLE CODE REQUIREMENTS IN REGARD TO REPORTED CAPACITY AND DEFLECTION REQUIREMENTS. 3.PRIOR TO EOR'S APPROVAL OF Z4 SHOP DRAWINGS, THE FRAMER, CONTRACTOR AND/OR CUSTOMER IS RESPONSIBLE FOR ANY CONSTRUCTION, INSTALLATION, AND/OR SHIPMENT OF Z4 TIE-DOWN SYSTEM MATERIAL. 4.AFTER EOR'S APPROVAL OF Z4 SHOP DRAWINGS, MiTek IS NOT RESPONSIBLE FOR ANY DEVIATION FROM THE RUN TYPE ELEVATIONS IN THIS SHOP DRAWING DURING CONSTRUCTION AND/OR INSTALLATION OF Z4 TIE-DOWN SYSTEM. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A.ENGINEER OF RECORD (EOR) SHALL CHECK COMPRESSION POST DESIGN CAPACITY FOR CONDITIONS SUBJECT TO ADDITIONAL LOADS SUCH AS BEAM OR HEADER REACTIONS. B.WHERE QUANTITY OF COMPRESSION POSTS ARE GREATER THAN THE SPACE BETWEEN ROD OR BEARING PLATE WASHER AND THE END OF THE SHEAR WALL, THE ADDITIONAL POSTS REQUIRED WILL BE ADDED TO THE OPPOSITE SIDE OF THE ROD. C.COMPRESSION POST SHALL BE OF SIZE, GRADE & SPECIES SPECIFIED. POSTS NOT SPECIFIED HEREIN SHALL BE THE RESPONSIBILITY OF THE EOR. D.THE COMPRESSION POSTS ON THE Z4 ELEVATIONS ARE DESIGNED TO THE WOOD SPECIES AND GRADE PER SHEET(S) S1.1 OF THE STRUCTURAL DOCUMENTS. THESE VALUES ARE SHOWN IN TABLE 7-D. E.THE WALL PLATES, USED FOR BPW AND CP DESIGN, ARE TO BE THE WOOD SPECIES AND GRADE SPECIFIED PER SHEET(S) S1.1 OF THE STRUCTURAL DOCUMENTS. THESE VALUES ARE SHOWN IN TABLE 7-E. F.DESIGN VALUE ADJUSTMENT FACTORS FOR FIRE-RETARDANT-TREATMENT USAGE ON COMPRESSION POSTS SHALL BE EQUAL TO OR GREATER THAN THE VALUES SHOWN IN TABLE 7-F. [ TABLE 7-E ]- - - - - - - [ TABLE 7-F ] - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - [ TABLE 7-D ] - - - - - - - - - - - - - - - - - - - - - - - - - - - 2x4:DF No. 2 Fc:0.86 FB:0.89 2x4:DF No. 2 4x6:N/A 4x12:N/A 6x6:N/A 6x12:N/A 2x6:DF No. 2 Fc(perp):0.86 Fv:0.88 3x4:N/A 4x8:N/A 2x6:DF No. 2 6x8:N/A 2x8:DF No. 2 2x8:DF No. 2 FT:0.84 E:0.95 4x4:N/A 4x10:N/A 3x6:N/A 6x10:N/A AB ANCHOR BOLT AOR ARCHITECT OF RECORD AT ANCHOR TIE ATR ALL THREADED ROD BPW BEARING PLATE WASHER CIP CAST-IN-PLACE CL CENTERLINE CMU CONCRETE MASONRY UNIT CNX CINCH NUT CNXO CINCH NUT OMEGA CONST CONSTRUCTION CP COMPRESSION POST(S) CPL COUPLER DF DOUGLAS-FIR LARCH DIA DIAMETER DIR DIRECTION EA EACH EN EDGE NAILING EOR ENGINEER OF RECORD F.F.FINISHED FLOOR FRT FIRE-RETARDANT TREATED E.G.LATIN: "FOR EXAMPLE" HDG HOT-DIP GALVANIZED HF HEM-FIR HS HIGH STRENGTH HT HEIGHT LVL, LV LEVEL MAX MAXIMUM MIN MINIMUM MS MID STRENGTH N/A NOT AVAILABLE / NOT APPLICABLE OC ON CENTER OS OVER-SIZED COUPLER HOLE PL PLATE QTY QUANTITY RFI REQUEST FOR INFORMATION SP SOUTHERN YELLOW PINE SPF SPRUCE-PINE-FIR STD STANDARD TDLP TIE-DOWN LAYOUT PLAN TYP TYPICAL UNC UNIFORM NATIONAL COARSE U.N.O.UNLESS NOTED OTHERWISE WS WOOD SCREW - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ABBREVIATIONS DISCLAIMER, SCOPE OF WORK, SYSTEM DESCRIPTION, GENERAL NOTES, & ABBREVIATIONSZ4-01 0 CINCH NUT (CNX) INSTALLATIONZ4-01 1 CNX BOTTOM ROD PER Z4 ELEVATION 1" MIN CNX BODY BPW PER Z4 ELEVATIONS WOOD PLATE PER PLAN ROD PER Z4 ELEVATIONS MiTek WS-3 SCREWS OR 1/4" LAG SCREW, TYP T W L BEARING PLATE WASHER (BPW) DIMENSIONSZ4-01 2 COUPLER (CPL) NUT & DESCRIPTIONSZ4-01 3 NOTES: 1.SEE DETAIL 1 FOR BPW DIMENSION DEFINITIONS. MIN WALL THICKNESS BEARING PLATE WASHER (BPW) DIMENSIONS [IN] DESIGNATION W L T HOLE DIA 4" BPW-5 (BROWN)3 3 1/4 1 5/16 BPW-6 (RED)3 1/4 3 3/8 3/8 1 9/16 BPW-7 (YELLOW)3 1/4 4 3/8 1/2 1 9/16 BPW-9 (GREEN)3 1/4 5 5/8 1 9/16 BPW-11 (BLUE)3 1/4 5 7/8 3/4 1 9/16 BPW-15 (BLACK)3 1/4 7 7/8 7/8 1 9/16 BPW-20 (WHITE)3 1/4 10 1/4 1 1/4 1 9/16 BPW-25 (ORANGE)3 1/2 11 3/4 1 1/2 1 9/16 BPW-30 (LIGHT GRAY)3 1/2 14 1 3/4 1 9/16 6" BPW-17-6 (LIGHT BLUE)5 5 7/8 5/8 1 9/16 BPW-27-6 (TAN)5 9 1 1 9/16 BPW-36-6 (GRAY)5 12 1 1/2 1 9/16 BPW-43-6 (PURPLE)5 14 1 3/4 1 9/16 BPW-46-6 (PINK)5 15 1 7/8 1 9/16 NOTES: 1.ALL ROD SHALL FULLY ENGAGE COULERS. 2.FOR STRAIGHT COUPLER NUTS, THREAD ROD IN HALF WAY FROM EACH SIDE, VISIBLE THROUGH SITE HOLE. 3.FOR COUPLER NUT REDUCERS, FULLY SEAT LARGE DIA. ROD FIRST, FULLY SEAT SMALL DIA. ROD SECOND, SO COUPLER CANNOT TURN. 4.USE SIGHT HOLES TO ENSURE PROPER INSTALLATION. STD COUPLER NUT REDUCER COUPLER NUT DIMENSIONS [IN] ROD H WF WC 1/2 1 1/2 7/8 1 5/8 1 7/8 1 1/16 1 1/4 3/4 2 1/4 1 1/4 1 7/16 7/8 2 5/8 1 7/16 1 11/16 1 3 1 5/8 1 7/8 1 1/8 3 3/8 1 13/16 2 1/16 1 1/4 3 3/4 2 2 5/16 1 3/8 4 1/8 2 3/16 2 17/32 1 1/2 4 1/2 2 3/8 2 3/4 1 3/4 5 1/4 2 3/4 3 3/16 2 6 3 1/8 3 5/8 STD COUPLER NUT MS COUPLER NUT REDUCER MS COUPLER NUT HS COUPLER NUT REDUCER SIGHT HOLE HS COUPLER NUT SIGHT HOLE SIGHT HOLE SIGHT HOLE H WF WC ATR TYPICAL ROD DIMENSIONSZ4-01 4 12" 24" 36" 48" 60" 72" 120" 144" NOMINAL ROD DIA 1/2" 3/4" 7/8" 1" 1 1/8" 1 1/4" 1 3/8" 1 1/2" 2" 6 OR MORE POSTS (SYMMETRIC)4 POSTS (SYMMETRIC) NOTES: 1. TABLE INDICATES EDGE NAIL SPACING AT COMPRESSION POSTS THAT MAY BE USED IN LIEU OF EDGE NAIL SPACING SPECIFIED IN EOR SHEAR WALL SCHEDULE UNLESS EXPLICITLY PROHIBITED BY THE EOR. 2. COMPRESSION POSTS NEED NOT BE STITCH NAILED U.N.O IN Z4 TYPICAL DETAILS OR IF REQUIRED PER EOR STRUCTURAL DOCUMENTS. COMPRESSION POST EDGE NAILING EDGE NAIL SPACING PER EOR SHEAR WALL SCHEDULE EDGE NAIL SPACING AT COMPRESSION POSTS 2 TO 3 POSTS 4 TO 5 POSTS 6 POSTS OR MORE 2" O.C.2" O.C.4" O.C.6" O.C. 3" O.C.3" O.C.6" O.C.9" O.C. 4" O.C.4" O.C.8" O.C.12" O.C. 6" O.C.6" O.C.12" O.C.12" O.C. 2 POSTS (SYMMETRIC) 6 OR MORE POSTS (ASYMMETRIC)4 OR 5 POSTS (ASYMMETRIC) COMPRESSION POSTS PER Z4 ELEVATIONS ROD PER Z4 ELEVATIONS ROD PER Z4 ELEVATIONS 3 POSTS (ASYMMETRIC) COMPRESSION POSTS PER Z4 ELEVATIONS EXAMPLE FULL HEIGHT COMPRESSION POST LAYOUT EXAMPLE BRIDGE COMPRESSION POST LAYOUT WITH BRIDGE BRIDGE = COMPRESSION POST (1) 4x4 (1) 2x4 (3) 2x4(1) 6x4 (1) 6x4 FULL HT. = COMPRESSION POST = BPW (1) 2x4 (1) 4x4 NOTES: 1.EXAMPLES SHOWN FOR 4" WALL FRAMING. 6" WALL FRAMING AND LARGER IS SIMILAR. 2.COMPRESSION POSTS SHOWN ARE THE MINIMAL REQUIREMENT TO EQUAL THE UPLIFT TENSION FORCES CALLED OUT BY THE STRUCTURAL DRAWINGS. ADDITIONAL COMPRESSION STUDS OR POSTS MAY BE REQUIRED BY STRUCTURAL ENGINEER OF RECORD. APPLIES TO ALL HOLDOWN RUNS. 3.COMPRESSION POSTS MUST BE LOCATED WITH THE BEARING ZONE AS SHOWN IN DETAILS 5 & 10. 4.ADJACENT FULL HEIGHT SHEARWALL FRAMING CAN BE USED AS COMPRESSION POSTS PROVIDED THEY ARE LOCATED WITHIN THE BEARING ZONE AS SHOWN IN DETAILS 5 & 10. 5.REFER TO DETAILS 5, 9, 10, & 11 FOR GAP SPACING LIMITATIONS U.N.O. 6.COMPRESSION POSTS CALLED OUT ON Z4 ELEVATION MAY BE REPLACED WITH ALTERNATE 2X MEMBERS OR VICE VERSA ONLY IF THE BEARING AREA MATCHES OR EXCEEDS THAT OF THE POSTS BEING REPLACED. 7.DRILLING OF COMPRESSION POSTS IS PERMITTED. RESULTING HOLE SHOULD NOT EXCEED 34" IN DIAMETER. 8.CUTTING OR NOTCHING OF TIE-DOWN SYSTEM COMPRESSION POSTS IS NOT ALLOWED. GAP SPACING GAP SPACING TYPICAL Z4 TIE-DOWN SYSTEM INSTALLATION DETAILZ4-01 5 ALLOWABLE ROD OFFSETZ4-01 6 OVERSIZE ROD HOLE: ROD DIA. + 1/2" MAX. CL POSTS PER ELEVATIONS ATR CNX PER PLAN NOTE: A 2" MAXIMUM ROD OFFSET FOR EACH 100" OF ROD HEIGHT IS PERMITTED. BLOCKING PER DETAIL 5 BPW PER PLAN CL AT PLUMB OF ANCHOR BELOW AB PER PLAN CPL FLOOR FRAMING BY OTHERS SILL PLATE BRIDGE TERMINATION AT TOP LEVELZ4-01 9 TOP PLATE TERMINATIONZ4-01 10 PER DETAIL 8, INSERT STITCH TO BRIDGE BLOCK STRAPS FROM FLOOR ABOVE PER PLAN, AS REQUIRED PE R Z 4 E L E V A T I O N S FLOOR FRAMING NAILING BETWEEN BRIDGE POSTS WHERE REQUIRED PER EOR PLANS Z4 ELEVATIONS WITH EDGE NAILING BRIDGE COMPRESSION POSTS PER TOP PLATES ROD CONTINUES TO FLOOR BELOW PER Z4 ELEVATION BPW & CNX AT SILL AS REQUIRED PER Z4 ELEVATION 16d EA. SIDE, STUD 8" MAX ROD PER Z4 ELEVATIONS BPW PER Z4 ELEVATIONS CNX PER Z4 ELEVATIONS FULL HT. COMPRESSION POSTS EACH SIDE WITH EDGE NAILING PER PROJECT PLAN. STITCH NAIL FULL HT. COMPRESSION POSTS TO BRIDGE COMPRESSION POST ON EACH SIDE, 16d AT 6" O.C. WHEN STRAPS OCCUR FROM FLOOR ABOVE STITCH NAIL FULL HT. STUD TO COMPRESSION POSTS, 2 ROWS 16d AT 6" O.C. STAGGERED. SILL PL 6x4 (4" WALL) OR 6x6 (6" WALL), MIN. NOTE: OVERTURNING FORCES ASSUMED TO BE EQUALLY DISTRIBUTED AMONGST BRIDGE POSTS. ADDITIONAL COMPRESSION FORCES ARE ASSUMED TO BE EQUALLY DISTRIBUTED AMONGST ALL FULL HT. COMPRESSION POSTS. 2" SOLID BLOCKING FOR FULLFLOOR FRAMING STRAPS PER PLAN (BY OTHERS) USE Z4 SPECIFIED POSTS OR STRAP FRAMING PER EOR PLANS, WHICHEVER IS LARGER STRAP FRAMING POSTS PER PLAN MAX. OR 6" MIN LENGTHBPW ROD PER Z4 ELEVATIONS BPW PER Z4 ELEVATIONS CNX PER Z4 ELEVATIONS WIDTH OF WALL AND FULL DEPTH OF FLOOR FRAMING EACH SIDE OF ROD. LENGTH TO MATCH POSTS BELOW. REFER TO EOR DOCUMENTS FOR SPECIFIC BLOCKING REQUIREMENTS STRAP TERMINATION OPTIONZ4-01 11 "CUMULATIVE LOAD DEMAND" NOTED ON Z4 ELEVATIONS. DISCONTINUOUS TIE-DOWN SHALL BE DESIGNED BY 3 12 x 3 12 x 38 TRANSITION WASHER w/ HOLE DIAMETER 116" GREATER THAN ROD TERMINATION AT WOOD BEAM NOTE: BPW & NUT PER Z4 RUN ELEVATIONS BEARING PLATE WASHER (BPW) TO MEET OR EXCEED BEAM SUPPORTING THE EOR SHEATHING NUT & WASHER RODCOUPLER NUT & WASHER TO MATCH ROD DIAMETER & GRADE COMPRESSION POSTS SILL PL ANCHOR TIE AT STEEL BEAMZ4-01 13 X 3"X3" FABRICATOR FOR SHOP WELDING. FOR NOT SHOWN SPECIAL INSPECTION OR APPROVED INFORMATION SEE AT-32 * REQUIRED. WELD SHALL MEET AWS D1.8 FIELD WELDING SPECIAL INSPECTION DETAIL FOR * AT-65 & AT-100 ANCHOR TIE NAILER * ANCHOR TIE AT-32 ROD SILL PL EA. SIDE. MINIMUM U.N.O. BY ENGINEER MIN. "t" = 1/4" MIN. IN ALL CASES,STEEL BEAM & NAILER PER PLAN COMPRESSION POSTS SILL PL STEEL BEAM3/16"STEEL BEAM ANCHOR TIE DEVICE HEIGHT WIDTH DEPTH 3X [IN]2CAPACITY [KIP] AT-32 9 3 1/2 3 1/4 32.4 AT-32L 16 3 1/2 3 1/4 32.4 AT-65 11 3/4 4 1/4 3 1/2 5/16 64.8 AT-65L 16 4 1/4 3 1/2 5/16 64.8 AT-100L 16 4 3/4 3 3/4 3/8 100.0 1. ALL PLATE MATERIAL IS ASTM A36. 2. ALLOWABLE UPLIFT LOADS ARE PER AISC NO INCREASE PERMITTED. 3. X VALUE INDICATES WELD THROAT SIZE FULL HEIGHT POSTS PER Z4 ELEVATIONS SILL PL ROD CONTINUES TO FLOOR BELOW PER Z4 ELEVATION BPW WITH LENGTH > 8" PER Z4 ELEVATIONS 2x POSTS ON BPW PER Z4 ELEVATIONS WITH EDGE NAILING NAILING PER DETAIL 8, INSERT STITCH NAILING 16d @ 6" O.C. INSTALLED FLUSH TO EDGE OF BPW ADDITIONAL POSTS ON BPW AS REQUIRED PER TIE-DOWN ELEVATION DETAILS UPDATED: 2022-01-13 TIE-DOWN SYSTEM LOAD PATHZ4-01 12 WOOD POSTS ARE ATTACHED TO SHEARWALL VIA NAILING UPLIFT OF WOOD POSTS DUE TO OVERTURNING (TENSION) FORCES OF SHEARWALL UPLIFT FORCES ARE TRANSFERRED TO BPW AND CNX VIA WOOD POSTS BEARING ON FLOOR BLOCKING AND/OR WOOD PLATES TENSION ROD RESISTS UPLIFT FORCES AND TRANSFERS LOADS TO FOUNDATION OR PODIUM OF STRUCTURE TENSION ROD TO RESIST AT-LEVEL TENSION FORCES AND TOTAL CUMULATIVE TENSION FORCES FROM LEVELS ABOVE BPW AND CNX TO RESIST AT-LEVEL TENSION FORCES ONLY COMPRESSION POST LAYOUTZ4-01 7 COMPRESSION POST EDGE NAILINGZ4-01 8 ANCHOR AT WOOD BEAMZ4-01 14 POSTS OVER BPWZ4-01 15 NOT USED CPL AND ROD FRAMING THRU FRAMING AS REQUIRED 2" Z4 ELEVATIONS 8" MAX ABOVE & BELOW FLOOR FRAMING ROD PER FLOOR COMPRESSION POSTS PER PLAN SNUG CNX TO BPW AND BPW TO TOP PLATE MAX. ELEVATIONS COMPRESSION POSTS PER PLAN BEARING ZONE 45° CNX PER Z4 TIGHTEN 1/4" LAG SCREW TO BPW PER PLAN JOIST SPACE 4 1/2" - 8 1/2" FROM END OF SHEAR WALL TO CENTERLINE OF ROD U.N.O. IN EOR STRUCTURAL DOCUMENTS OR Z4 ELEVATIONS SPLICE WITHIN 8" OF ROD 6" MAX BPW & CNX AT SILL AS REQUIRED NAILING WHERE REQUIRED PER EOR PLANS FLOOR FRAMING TOP PLATES - DO NOT ROD CONTINUES TO FLOOR BELOW PER Z4 ELEVATION BEARING ZONE 45° PER Z4 ELEVATIONS THRU FRAMING ROD PER Z4 ELEVATIONS BPW PER Z4 ELEVATIONS CNX PER Z4 ELEVATIONS COMPRESSION POSTS PER Z4 ELEVATION WITH EDGE NAILING PER DETAIL 8, INSERT STITCH SILL PL SOLID BLOCKING FOR FULL WIDTH OF WALL AND FULL DEPTH OF FLOOR FRAMING EACH SIDE OF ROD. LENGTH TO MATCH POSTS BELOW. U.N.O. IN EOR DOCUMENTS, REFER TO EOR DOCUMENTS FOR SPECIFIC BLOCKING REQUIREMENTS X HOLE DIA ROD DIA MIN X MAX X < 1"ROD DIA + 1/2"1 5/8" 1" - 1 1/2"ROD DIA + 1/2"2" > 1 1/2"ROD DIA + 1/2"2 1/2" ROD DIA MIN X MAX X < 1"ROD DIA + 1/2"1 5/8" 1" - 1 1/2"ROD DIA + 1/2"2" > 1 1/2"ROD DIA + 1/2"2 1/2" X HOLE DIA X HOLE DIA DE T A I L S U P D A T E D : 2 0 2 2 - 0 1 - 1 3 Z4-01 Mi T e k Z 4 T Y P I C A L D E T A I L S 10/08/202001/11/2024 STATEMENT OF GENERAL CONFORMANCE FOR PROJECTS WHICH UTILIZE "DEFERRED SUBMITTAL" PLANS, INCLUDING BUT NOT LIMITED TO SHOP DRAWINGS,PREPARED BY OTHER LICENSED DESIGN PROFESSIONALS AND/OR CONSULTANTS, NOT UNDER RESPONSIBLE CHARGE/DIRECTION OF THE DESIGNATED ARCHITECT/ENGINEER OF RECORD (CITY PERMIT NO. _____________________________________) o THE DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET o THIS DRAWING, PAGE OF SPECIFICATIONS/CALCULATIONS HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARE LICENSED AND/OR AUTHORIZED TO PREPARE SUCH DRAWINGS IN THIS STATE. IT HAS BEEN EXAMINED BY ME FOR: 1.DESIGN INTENT AND APPEARS TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CALIFORNIA CODE OF REGULATIONS AND THE PROJECT SPECIFICATIONS PREPARED BY ME, AND 2.COORDINATION WITH MY PLANS AND SPECIFICATIONS AND IS ACCEPTABLE FOR INCORPORATION INTO THE CONSTRUCTION OF THIS PROJECT. THE STATEMENT OF GENERAL CONFORMANCE SHALL NOT BE CONSTRUED AS RELIEVING ME, OR THE PERSON UNDER WHOSE DIRECT SUPERVISION THESE DOCUMENTS WERE PREPARED, OF OUR RIGHTS, DUTIES, AND RESPONSIBILITIES UNDER APPLICABLE SECTIONS OF THE CALIFORNIA BUILDING CODE. I CERTIFY THAT: ALL DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET THIS DRAWING OR PAGE IS/ARE IN GENERAL CONFORMANCE AND HAVE BEEN COORDINATED SIGNATURE DATE ARCHITECT / ENGINEER IN GENERAL RESPONSIBLE CHARGE OR DELEGATED STRUCTURAL ENGINEER PRINT NAME LICENSE NUMBER EXPIRATION XX X Kenneth D. O'Dell 2024-03-20 S4101 - California 6/30/2025 X 03/27/2024 7 & 9 Z4-01 7 & 9 Z4-01 7 & 9 Z4-01 7 & 9 Z4-01 7 & 9 Z4-01 7 & 9 Z4-01 7 & 9 Z4-01 7 & 9 Z4-01 72 " 6x6 (2) 2x6 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 5 5000 6903 5000 5657 4 10000 13530 5000 5657 3 17500 17671 7500 7688 10 " 10 " 12 0 " 12 0 " 11 0 " 3 4 FLOOR FRAMING BY OTHERS 5 FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX 12 0 " 12 0 " 84 " 1" A36 ATR 1" STD CPL 7/8" A36 ATR 7/8" - 1" STD CPL 5/8" A36 ATR 5/8" - 7/8" STD CPL CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 6"5 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 3.21 Z4-02 [35.PD] (2) 2x6 (2) 2x6(2) 2x6 (4) 2x6(2) 2x6 72 " 6x6 (3) 2x6 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 5 5000 6903 5000 6612 4 10000 13530 5000 6612 3 17500 17671 7500 7704 1" 1" 12 0 " 12 0 " 11 0 " 3 4 FLOOR FRAMING BY OTHERS 5 FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX 12 0 " 12 0 " 84 " 1" A36 ATR 1" STD CPL 7/8" A36 ATR 7/8" - 1" STD CPL 5/8" A36 ATR 5/8" - 7/8" STD CPL CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 6"13 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 3.22 Z4-02 [35.PD-34TC-FRT] (2) 2x6 (2) 2x6(2) 2x6 (5) 2x6(2) 2x6 72 " 6x6 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 5 7500 9940 7500 7704 4 17500 17671 10000 14758 3 27500 27612 10000 14758 1" 1" 12 0 " 12 0 " 11 0 " 3 4 FLOOR FRAMING BY OTHERS 5 FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX 12 0 " 12 0 " 84 " 1 1/4" A36 ATR 1 1/4" STD CPL 1" A36 ATR 1" - 1 1/4" STD CPL 3/4" A36 ATR 3/4" - 1" STD CPL CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 6"10 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 3.33 Z4-02 [35.PD-34TC-FRT] (2) 2x6 (3) 2x6(2) 2x6 (8) 2x6(2) 2x6 (5) 2x6 72 " 6x6 (6) 2x6 10 " 10 " 10 " 12 0 " 12 0 " 12 0 " 10 7 " 3 4 FLOOR FRAMING BY OTHERS 5 6 FLOOR FRAMING BY OTHERS FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX 12 0 " 12 0 " 12 0 " 84 " 1 1/4" A36 ATR 1 1/8" - 1 1/4" HS CPL 1" A36 ATR 1" - 1 1/4" STD CPL 7/8" A36 ATR 7/8" - 1" STD CPL 5/8" A36 ATR 5/8" - 7/8" STD CPL CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 6"61 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 4.14 Z4-02 [36.PD] (2) 2x6 (2) 2x6(2) 2x6 (10) 2x6(2) 2x6 (4) 2x6(2) 2x6 72 " 6x6 (6) 2x6 1" 1" 1" 12 0 " 12 0 " 12 0 " 10 7 " 3 4 FLOOR FRAMING BY OTHERS 5 6 FLOOR FRAMING BY OTHERS FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX 12 0 " 12 0 " 12 0 " 84 " 1 1/4" A36 ATR 1 1/8" - 1 1/4" HS CPL 1" A36 ATR 1" - 1 1/4" STD CPL 7/8" A36 ATR 7/8" - 1" STD CPL 5/8" A36 ATR 5/8" - 7/8" STD CPL CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 6"20 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 4.15 Z4-02 [36.PD-35TC] (2) 2x6 (2) 2x6(2) 2x6 (10) 2x6(2) 2x6 (4) 2x6(2) 2x6 72 " 6x8 10 " 10 " 10 " 12 0 " 12 0 " 12 0 " 10 7 " 3 4 FLOOR FRAMING BY OTHERS 5 6 FLOOR FRAMING BY OTHERS FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX 12 0 " 12 0 " 12 0 " 84 " 1 1/4" A36 ATR 1 1/8" - 1 1/4" HS CPL 1" A36 ATR 1" - 1 1/4" STD CPL 7/8" A36 ATR 7/8" - 1" STD CPL 5/8" A36 ATR 5/8" - 7/8" STD CPL CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 8"5 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 4.16 Z4-02 [36.PD] (8) 2x8(2) 2x8 (5) 2x8(2) 2x8 (3) 2x8(2) 2x8 (2) 2x8 (2) 2x8 72 " 6x6 (8) 2x6 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 6 5000 6903 5000 6612 5 10000 13530 5000 6612 4 17500 17671 7500 7704 3 25000 27612 7500 7704 1" 1" 1" 12 0 " 12 0 " 12 0 " 10 7 " 3 4 FLOOR FRAMING BY OTHERS 5 6 FLOOR FRAMING BY OTHERS FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX 12 0 " 12 0 " 12 0 " 84 " 1 1/4" A36 ATR 1 1/8" - 1 1/4" HS CPL 1" A36 ATR 1" - 1 1/4" STD CPL 7/8" A36 ATR 7/8" - 1" STD CPL 5/8" A36 ATR 5/8" - 7/8" STD CPL CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 6"2 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 4.17 Z4-02 [36.PD-35TC-FRT] (2) 2x6 (2) 2x6(2) 2x6 (12) 2x6(2) 2x6 (5) 2x6(2) 2x6 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 6 5000 6903 5000 5657 5 10000 13530 5000 5657 4 17500 17671 7500 7688 3 25000 27612 7500 7688 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 6 5000 6903 5000 5657 5 10000 13530 5000 5657 4 17500 17671 7500 7688 3 25000 27612 7500 7688 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 6 5000 6903 5000 5657 5 10000 13530 5000 5657 4 17500 17671 7500 7688 3 25000 27612 7500 7688 72 " 6x6 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 5 10000 13530 10000 13530 4 17500 17671 7500 7704 3 25000 27612 7500 7704 1" 1" 12 0 " 12 0 " 11 0 " 3 4 FLOOR FRAMING BY OTHERS 5 FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 6"4 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 4.18 Z4-02 [35.PD-34TC-FRT] 12 0 " 12 0 " 84 " 1 1/4" A36 ATR 1 1/8" - 1 1/4" HS CPL 1" A36 ATR 1" - 1 1/4" STD CPL 7/8" A36 ATR 7/8" - 1" STD CPL (6) 2x6(4) 2x6 (6) 2x6 (10) 2x6 (4) 2x6 (4) 2x6 7 & 9 Z4-01 72 " 6x6 (6) 2x6 1" 1" 1" 12 0 " 12 0 " 12 0 " 10 7 " 3 4 FLOOR FRAMING BY OTHERS 5 6 FLOOR FRAMING BY OTHERS FLOOR FRAMING BY OTHERS 8" MIN - 12" MAX 12 0 " 12 0 " 12 0 " 84 " 1 3/8" A36 ATR 1 1/4" - 1 3/8" HS CPL 1 1/8" A36 ATR 1 1/8" - 1 3/8" STD CPL 7/8" A36 ATR 7/8" - 1 1/8" STD CPL 5/8" A36 ATR 5/8" - 7/8" STD CPL CONCRETE ANCHOR PER EOR STRUCTURAL DOCUMENTS RUNTYPE NAME [RUNTYPE DESCRIPTION]: WALL DEPTH:RUNTYPE QTY: 6"22 NOTE:C = CIP ANCHOR, E = EPOXY ANCHOR 4.29 Z4-02 [36.PD-35TC] (2) 2x6 (2) 2x6(2) 2x6 (2) 2x6 (4) 2x6 (2) 2x6 LV L CUMULATIVE TENSION LOAD (ASD) [lbs]LEVEL TENSION LOAD (ASD) [lbs] DEMAND CAPACITY DEMAND CAPACITY 6 5000 6903 5000 5657 5 10000 13530 5000 5657 4 20000 22365 10000 10735 3 30000 33410 10000 17161 NOT USED NOT USED (2) 2x6 CNX-5BPW-6 (RED) CNX-7BPW-6 (RED) CNX-8BPW-7 (YELLOW) CNX-7BPW-7 (YELLOW) CNX-8BPW-9 (GREEN) CNX-5BPW-7 (YELLOW) CNX-5 BPW-6 (RED) CNX-7BPW-6 (RED) CNX-10BPW-7 (YELLOW) CNX-8BPW-7 (YELLOW) CNX-5 BPW-6 (RED) CNX-7BPW-6 (RED) CNX-10BPW-7 (YELLOW) CNX-8BPW-7 (YELLOW) CNX-5 BPW-6 (RED) CNX-7BPW-6 (RED) CNX-10BPW-7 (YELLOW) CNX-8BPW-7 (YELLOW) CNX-7BPW-7 (YELLOW) CNX-8BPW-9 (GREEN) CNX-5 BPW-7 (YELLOW) CNX-10BPW-9 (GREEN)CNX-8BPW-9 (GREEN) CNX-8BPW-9 (GREEN) CNX-10BPW-9 (GREEN) CNX-7BPW-17-6 (LIGHT BLUE) CNX-5 BPW-6 (RED) CNX-7BPW-6 (RED) CNX-9BPW-11 (BLUE) CNX-11BPW-17-6 (LIGHT BLUE) 1 CNX-6BPW-9 (GREEN) CNX-10BPW-17-6 (LIGHT BLUE) CNX-8BPW-17-6 (LIGHT BLUE) 1 1 1 1 1 1 1 1 1 MiTek Z4 RUNTYPE NOMENCLATURE EXAMPLE: ABBREVIATIONS: NOTE: UNDERLINED LETTERS INDICATE NUMBER VALUE TIE-DOWN ANCHOR (CAST-IN-PLACE) TIE-DOWN CONCRETE CAST-IN-PLACE ANCHOR PER EOR STRUCTURAL DOCUMENTS. REFER TO GENERAL NOTE 6 OF DETAIL 0/Z4-01 FOR OTHER TIE-DOWN ANCHOR REQUIREMENTS. BRIDGE CONDITION COMPRESSION FORCES ARE ASSUMED TO BE EQUALLY DISTRIBUTED AMONGST ALL FULL HT COMPRESSION POSTS. COMPRESSION BASED ON POST CAPACITIES COMPRESSION DEMAND LOADS WERE NOT PROVIDED FOR THIS SUBMITTAL. COMPRESSION POSTS HAVE BEEN DESIGNED TO MEET OR EXCEED CAPACITY OF POST ASSEMBLIES SPECIFIED ON EOR STRUCTURAL DOCUMENTS. EOR TO VERIFY AND APPROVE DESIGN. CNX AND CNXO DEVICES CNX AND CNXO DEVICES ARE INTERCHANGEABLE WOOD SHRINKAGE COMPENSATION DEVICES WITH NO DIFFERENCES IN CAPACITY OR INSTALLATION. CNXO TO EVENTUALLY COMPLETELY REPLACE CNX DEVICES. OTHER CONDITIONS (PREFIXED WITH STARTING AND ENDING LEVEL AS NEEDED) RUNTYPE NAME PER EOR PLANS OR, IF NOT PROVIDED, PER DEMAND LOADING CONDITIONS STARTING AND ENDING LEVEL PER ARCHITECTURAL PLANS STARTING CONDITION(S) RUNTYPE DESCRIPTION A [25.PD-FRT] STARTING CONDITIONS CF CONCRETE SLAB (FOUNDATION) CW CONCRETE WALL MW CONCRETE MASONRY WALL PD ELEVATED CONCRETE SLAB (PODIUM) SB STEEL BEAM SP STEEL PLATE WB WOOD BEAM TB THROUGH-BOLT XC CONCRETE CURB, WHERE X = HEIGHT (IN) XCS CRAWL SPACE, WHERE X = HEIGHT (IN) AX ANCHOR DIA, WHERE X = DIA (1/8 IN) BP BPW AT FOUNDATION SILL PLATE OTHER CONDITIONS XBW BALLOON-WALL FRAMING AT LVL X FRT FIRE-RETARDANT TREATED LUMBER PW SHEAR PARTY WALL XSI STEEL BEAM INTERRUPTION AT LVL X TC TOP-CHORD BEARING, JOIST HANGING, OR SEMI-BALLOON FLOOR FRAMING XXX TOTAL LEVEL DEFLECTION LIMIT (1/1000 IN) XDY WALL DEPTH CHANGES TO Y (IN) AT LVL X XHY SPECIAL FLOOR HT CONDITION X = FLOOR LVL, Y = FLOOR HT CONDITION XFFY SPECIAL FLOOR FRAMING DEPTH X = FLOOR LVL, Y = FLOOR DEPTH (IN) HDC TRADITIONAL HOLD DOWN CONVERSION TIE-DOWN ELEVATION NOTES 16 0 2 3 S w i n g l e y R i d g e R o a d , C h e s t e r f i e l d , M O 6 3 0 1 7 T: ( 9 5 1 ) 2 6 8 - 3 6 7 0 F : ( 9 5 1 ) 2 7 3 - 0 0 4 0 HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . , A R C A D I A , C A GE N E R I C S U B M I T T A L REVISION DATE DESCRIPTION 1 2024-01-11 UPDATE PLANS Z4 PROJECT No.: 2300954 SCALE: NOT TO SCALE ISSUE DATE (YYYY-MM-DD): 2023-11-23 DRAWN BY: HUONG CHECKED BY: LW SHEET No.: PR O J E C T N A M E : SH E E T N A M E : Mi T e k Z 4 T I E - D O W N E L E V A T I O N S Z4-02 10/08/202001/11/2024 03/27/2024 D1 D2 D3 D3.1 D4 D5 D5.5 D6 D7 D8 D8.1 D10 D11 D11.5 D12 FROM GL D1 TO D11 7 STAIR 1 C S5.3 DA DB UP DN P12 C7 C7 DB.4P1 P11 SB4 HSS10x6x1/2 C7 DC HSS10x6x1/2 DC.5 5 P12-1" THICKENED SLAB AT STEP 16 S4.3 DD.2 DD.5 16 S4.3 E5 1 S3.0 TYP DE.5 5 E5 E5 A DF.5 DF DG DG.5 B5 E5 DH DH.5 C5 E5 DJ DI.5 B5 E5 DK DK.5 E5 27.5' E5 DL DL.5 P1 B5 16.5' DM DN DP P1 UP DN P1 P1 P1 -8"STAIR 2 H S5.3 P1 B5 5.5' B5 5.5' DP P1 B5 16' -8" 5.5' P11 P11 B5 15.5' P1 P1 P1 F6 5.5' DM DN D7 D8.1 D10 D11 D11.5 D11.9D12 DL.5 S4.4 TYP 4 P1 P1 THICKENED SLAB AT STEP F6 5.5'DL 5.5' -8" DK.5 17.5' B5 9' E5 17.5' B5 9' B5 18'F6 5.5'DK 5.5' S4.4 TYP 4 DI.5 29.5' C5 29.5'F6 5.5'DJ 5.5' 17.5' 5.5' E5 17.5' DF.5 E5 5.5' C5 18' C5 8' C5 29.5'F6 5.5'DG S6.1 TYP 6 B5 9' DG.5 E5 17.5' E5 17.5' B5 9' B5 18'F6 5.5'DH DH.5 17.5'F6 5.5' S4.3 TYP 5.5' C5 18' C5 8' C5 29.5' DE.5 DF F6 5.5'DE B5 -8"F3 5.5' F3 5.5' F3 5.5' F3 5.5' F3 5.5'4 S4.4 TYP DD.5 17.5' P1 B5 9' E5 13' E5 17.5' B5 9' B5 18'F6 5.5'DD P12 S4.3 TYP C2 24.5'C2 29.5'C2 29.5' DC.5 E5 31' C7 E5 17.5' P1 F5 28'F6 5.5'DC P12 D2 8.5' D2 8.5' D2 8.5' S4.3 D2 8.5' D2 8.5' D2 8.5' B5 8.5' P1 P1 P1 F6 5.5' P1 DB B5 8.5' P1 B5 30.5' DA S4.3 TYP 5 1' - 0 " HS S 1 0 x 6 x 1 / 2 HS S 1 0 x 6 x 1 / 2 -1 " 4' - 0 " -8 " FLOOR REFERENCE:STRUCTURAL PAGE REFERENCE: STRUCTURAL DRAWING DATE: THIRD FLOOR FRAMING PLAN S2.3B 2023-06-05 1 1 1 1 1 Z4-02 1 Z4-02 1 Z4-02 2 Z4-02 2 Z4-02 2 Z4-02 2 Z4-02 2 Z4-02 2 Z4-02 8 Z4-02 8 Z4-02 2 Z4-02 3 Z4-02 3 Z4-02 3 Z4-02 3 Z4-02 3 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 4 Z4-02 5 Z4-02 5 Z4-02 5 Z4-02 5 Z4-02 5 Z4-02 5 Z4-02 5 Z4-02 5 Z4-02 5 Z4-02 5 Z4-02 4 Z4-02 6 Z4-02 6 Z4-02 6 Z4-02 6 Z4-02 6 Z4-02 7 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 9 Z4-02 GENERIC SUBMITTAL REFER TO SHEETS Z4-01 TO Z4-02 FOR DETAILS AND ELEVATIONS PERTAINING TO THE Z4 TIE-DOWN SYSTEM. ENGINEER OF RECORD (EOR):MHP STRUCTURAL ENGINEERS EOR PROJECT No.:LA21.522 LEGEND TIE-DOWN ELEVATION REFERENCE A =TIE-DOWN ELEVATION NUMBER XX =SHEET NUMBER A Z4-XX 16 0 2 3 S w i n g l e y R i d g e R o a d , C h e s t e r f i e l d , M O 6 3 0 1 7 T: ( 9 5 1 ) 2 6 8 - 3 6 7 0 F : ( 9 5 1 ) 2 7 3 - 0 0 4 0 HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . , A R C A D I A , C A GE N E R I C S U B M I T T A L REVISION DATE DESCRIPTION 1 2024-01-11 UPDATE PLANS Z4 PROJECT No.: 2300954 SCALE: NOT TO SCALE ISSUE DATE (YYYY-MM-DD): 2023-11-23 DRAWN BY: HUONG CHECKED BY: LW SHEET No.: PR O J E C T N A M E : SH E E T N A M E : TDLP-01 Mi T e k Z 4 T I E - D O W N L A Y O U T P L A N NOTE: SEAL ON TIE-DOWN LAYOUT SHEETS FOR Z4 TIE-DOWN DESIGNS ONLY. MiTek DID NOT PARTICIPATE IN THE PREPARATION OR REVIEW OF THE PROJECT DESIGN OR DRAWINGS, THEREBY MiTek's LIABILITY IS LIMITED TO THE DESIGN OF THE Z4 TIE-DOWN COMPONENTS. 10/08/202001/11/2024 03/27/2024 ▄▄▄▄ MiTek Z4 Tie-Down Systems Continuous Rod System Submittal Z4 SUBMITTAL INFORMATION Date: 2024-01-11 Revision: DELTA 1 (R1) Submittal Type:GENERIC SUBMITTAL PROJECT INFORMATION Project Name: HILTON ARCADIA Project Address: 123 W HUNTINGTON DR. ARCADIA, CA Engineer of Record (EOR): MHP STRUCTURAL ENGINEERS Architect of Record (AOR): AXIS/GFA ARCHITECTURE + DESIGN Structural Plan Date: 2023-11-21 Jurisdiction: CITY OF ARCADIA SUBMITTAL PACKAGE EOR shall verify that the load values (demands) used meet the EOR's design intent. CONTINUOUS ROD SYSTEM (Z4) • Overturning forces are transferred from the structural sheathing to the wood posts. • Shearwall overturning forces generate tension and compression loads at opposite ends of the shearwall. • • • Cinch Nuts (CNX) transfer load from the bearing plate to continuous rod per level. • Tension loads are accumulated in the rod. • CNX provides perpetual shrinkage compensation. DELIVERABLES • • ENGINEER OF RECORD (EOR) ARCHITECT OF RECORD (AOR) Thank you for using MiTek Z4 Tie-Down Systems. Sincerely, MiTek Z4 Engineering Team E-Mail: GRP-RES-NA-Z4-Engineering@mii.com The following Z4 Calculations are provided along with the detail and elevation sheets as a deferred submittal to the tie-down system specified in the construction documents. These documents have been submitted to the Engineer of Record (EOR) and bear their shop drawing stamp as an accepted specification. For evaluation reports please refer to ICC ESR No. 2190 and/or Los Angeles RR No. 25623. Please review submittal package as part of your coordination with the construction documents and comment as necessary. During your review if you should have any questions please contact MiTek Z4 Engineering or Customer Service at (951) 245- 9525. Please provide your shop drawing review stamp on the following sheets: the first page of the calculation package, the first page of the shop drawings (Z4-01), and the first page of the tie down layout plans (TDLP-01). Keep a copy for your records. Inform Architect of your receipt of the documents and forward to them for their use & approval. Please review submittal package as part of your coordination with the construction documents and comment as necessary. (1) Electronic set of sealed calculations showing the design of the Z4 system that meets or exceeds project demand with corresponding Z4 runtype names. (1) Electronic set of sealed elevations & details showing parts and installation configurations, as well as placement plans showing the locations of the Z4 runtypes where different from those originally specified on the plans. If the Z4 runtype names are identical to the runtype names specified on the plans a placement plan is not required. Compression loads accumulate in the wood posts from the top to the bottom level. If the EOR specifies the compression load Z4 will include in the design. Uplift (tension loads): wood posts push up and are resisted by the bearing plates above. The tension load specified by the EOR is included as the basis of the Z4 Design. 555 S. Promenade Avenue, St 104 Corona, CA 92879 Tel. 951-245-9525 10/08/202001/11/2024 03/27/2024 ▄▄▄▄ MiTek Z4 Tie-Down Systems Revised Submittal Narrative Letter Z4 SUBMITTAL INFORMATION Date: 2024-01-11 Revision: DELTA 1 (R1) Reason for Revised Submittal:EOR Comments on Previous Submittal PROJECT INFORMATION Project Name: HILTON ARCADIA Project Address: 123 W HUNTINGTON DR. ARCADIA, CA Engineer of Record (EOR): MHP STRUCTURAL ENGINEERS NARRATIVE LETTER To: Whom it May Concern From: MiTek Z4 Engineering Team GRP-RES-NA-Z4-Engineering@mii.com MiTek USA, Inc. Regarding: Narrative of MiTek Z4 Submittal Package Revision Delta 1 (R1) (Sealed: 2024-01-11) • • • This revision will override the submittal package previously submitted. Sincerely, MiTek Z4 Engineering Team This narrative letter addresses a brief summary of the modifications made to the MiTek Z4 Submittal Package for the project ''HILTON ARCADIA''. The modifications are as follows: This narrative may not provide an exhaustive list of all changes in the latest revision of the MiTek Z4 Submittal Package and must be reviewed by the Engineer of Record (EOR). If you have any additional questions or concerns, please feel free to contact the Z4 engineering team at your convenience. Total run count increased (R0: 138, R1: 142) Runtype QTYs updated: 4/Z4-02 and 5/Z4-02 Runtype design updated: 3/Z4-02 555 S. Promenade Avenue, St 104 Corona, CA 92879 Tel. 951-245-9525 10/08/202001/11/2024 ▄▄▄▄ MiTek Z4 Tie-Down Systems Bridge Design Z4 SUBMITTAL INFORMATION Date: 2024-01-11 Revision: DELTA 1 (R1) PROJECT INFORMATION Project Name: HILTON ARCADIA Project Address: 123 W HUNTINGTON DR. ARCADIA, CA Engineer of Record (EOR): MHP STRUCTURAL ENGINEERS If you have any additional questions or concerns, please contact the MiTek Z4 Engineering team at your convenience. Sincerely, MiTek Z4 Engineering Team GRP-RES-NA-Z4-Engineering@mii.com This is an explanation of how MiTek Z4 Engineering designs compression posts for a bridge assembly at the terminating level of the tie-down system. The full height posts (see Figure 1) are designed for additional compression demand (E.G. dead loads) as well as a portion of the overturning level tension demand. See equation (1) below. Figure 1 - Bridge at Terminating Level Example (1) Where C ADD = Additional Compression Demand, LB = Bridge Post Height, LF = Full Ht Post Height, t = Level Tension Demand. A portion of the overturning tension demand is distributed to the full height posts based on the geometry of the post heights. This is because of bridge posts, which are designed to resist the overturning tension which is equal to the overturning compression, do in fact transfer a portion of the level tension to the full height posts via stich nailing. Therefore, the MiTek Z4 submittal calculations package will show the distributed full height compression demand from equation (1) in lieu of the compression demands shown on the EOR structural documents. Full Height Compression Post Demand = IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 01/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 01/Z4-02 - Level 5 (110")A36 5/8 x 120 69.5 6903 0.048 BPW-6 5657 0.031 CNX-5 14067 0.016 0.098 0.200 0.884 5000 5000 72 A36 7/8 x 120 8 13530 0.003 01/Z4-02 - Level 4 (120")A36 7/8 x 120 112 13530 0.077 BPW-6 5657 0.031 CNX-7 28187 0.013 0.126 0.200 0.884 5000 10000 -A36 1 x 120 8 17671 0.004 01/Z4-02 - Level 3 (120")A36 1 x 120 112 17671 0.103 BPW-7 7688 0.038 CNX-8 29283 0.016 0.164 0.200 0.990 7500 17500 -B7 1 x 24 8 36816 0.007 Comments: 3.2 [35.PD] [6"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 1 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing Tension Comp.Level Compression Posts Summary Run: 01/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 110 2x6 DF No.2 [Full Height Post] (1)5156 110 2x6 DF No.2 [Full Height Post] (1)5156 72 2x6 DF No.2 [Bridge Post] (1)5156 72 2x6 DF No.2 [Bridge Post] (1)5156 Totals:Bridge Posts (Tension Chord)5156 5156 10313 0.485 Totals:Full Height Posts (Comp. Chord)5156 5156 15.00 10313 0.110 110 2x6 DF No.2 [Full Height Post] (2)10313 110 2x6 DF No.2 [Full Height Post] (2)10313 Totals:Full Height Posts (Tension Chord)10313 10313 20625 0.242 Totals:Full Height Posts (Comp. Chord)10313 10313 15.00 20625 0.485 110 2x6 DF No.2 [Full Height Post] (2)10313 110 2x6 DF No.2 [Full Height Post] (4)20625 Totals:Full Height Posts (Tension Chord)10313 20625 30938 0.242 Totals:Full Height Posts (Comp. Chord)10313 20625 15.00 30938 0.566 2Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 01/Z4-02 - Level 5 - Wall: 5.5" -5000 1131 110 01/Z4-02 - Level 4 - Wall: 5.5" 5000 -10000 120 01/Z4-02 - Level 3 - Wall: 5.5" 7500 -17500 120 10/08/202001/11/2024 IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 02/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 02/Z4-02 - Level 5 (110")A36 5/8 x 120 69.5 6903 0.048 BPW-7 6612 0.022 CNX-5 14067 0.016 0.088 0.200 0.756 5000 5000 72 A36 7/8 x 120 8 13530 0.003 02/Z4-02 - Level 4 (120")A36 7/8 x 120 112 13530 0.077 BPW-7 6612 0.022 CNX-7 28187 0.013 0.116 0.200 0.756 5000 10000 -A36 1 x 120 8 17671 0.004 02/Z4-02 - Level 3 (120")A36 1 x 120 112 17671 0.103 BPW-9 7704 0.038 CNX-8 29283 0.016 0.164 0.200 0.990 7500 17500 -B7 1 x 24 8 36816 0.007 Comments: 3.2 [35.PD-34TC-FRT] [6"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 3 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing *Fire Treated* Tension Comp.Level Compression Posts Summary Run: 02/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 110 2x6 DF No.2 [Full Height Post] (1)4434 110 2x6 DF No.2 [Full Height Post] (1)4434 72 2x6 DF No.2 [Bridge Post] (1)4434 72 2x6 DF No.2 [Bridge Post] (1)4434 Totals:Bridge Posts (Tension Chord)4434 4434 8869 0.564 Totals:Full Height Posts (Comp. Chord)4434 4434 16.50 8869 0.128 119 2x6 DF No.2 [Full Height Post] (2)8869 119 2x6 DF No.2 [Full Height Post] (3)13303 Totals:Full Height Posts (Tension Chord)8869 9423 18292 0.273 Totals:Full Height Posts (Comp. Chord)8869 13303 16.50 22172 0.451 119 2x6 DF No.2 [Full Height Post] (2)8869 119 2x6 DF No.2 [Full Height Post] (5)22172 Totals:Full Height Posts (Tension Chord)8869 10347 19216 0.390 Totals:Full Height Posts (Comp. Chord)8869 22172 16.50 31041 0.564 4Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 02/Z4-02 - Level 5 - Wall: 5.5" -5000 1131 110 02/Z4-02 - Level 4 - Wall: 5.5" 5000 -10000 120 02/Z4-02 - Level 3 - Wall: 5.5" 7500 -17500 120 10/08/202001/11/2024 IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 03/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 03/Z4-02 - Level 5 (110")A36 3/4 x 120 69.5 9940 0.049 BPW-9 7704 0.038 CNX-6 16942 0.020 0.110 0.200 0.974 7500 7500 72 A36 1 x 120 8 17671 0.003 03/Z4-02 - Level 4 (120")A36 1 x 120 112 17671 0.103 BPW-17-6 14758 0.019 CNX-8 29283 0.018 0.144 0.200 0.990 10000 17500 -A36 1 1/4 x 120 8 27612 0.005 03/Z4-02 - Level 3 (120")A36 1 1/4 x 120 112 27612 0.102 BPW-17-6 14758 0.019 CNX-10 54190 0.018 0.146 0.200 0.996 10000 27500 -B7 1 1/4 x 24 8 57524 0.007 Comments: 3.3 [35.PD-34TC] [6"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 5 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing *Fire Treated* Tension Comp.Level Compression Posts Summary Run: 03/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 110 2x6 DF No.2 [Full Height Post] (1)4434 110 2x6 DF No.2 [Full Height Post] (2)8869 72 2x6 DF No.2 [Bridge Post] (1)4434 72 2x6 DF No.2 [Bridge Post] (1)4434 Totals:Bridge Posts (Tension Chord)4434 4434 8869 0.846 Totals:Full Height Posts (Comp. Chord)4434 8869 21.00 13303 0.127 119 2x6 DF No.2 [Full Height Post] (2)8869 119 2x6 DF No.2 [Full Height Post] (5)22172 Totals:Full Height Posts (Tension Chord)8869 11640 20509 0.488 Totals:Full Height Posts (Comp. Chord)8869 22172 21.00 31041 0.564 119 2x6 DF No.2 [Full Height Post] (2)8869 119 2x6 DF No.2 [Full Height Post] (8)35475 Totals:Full Height Posts (Tension Chord)8869 11640 20509 0.488 Totals:Full Height Posts (Comp. Chord)8869 35475 21.00 44344 0.620 6Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 03/Z4-02 - Level 5 - Wall: 5.5" -7500 1696 110 03/Z4-02 - Level 4 - Wall: 5.5" 10000 -17500 120 03/Z4-02 - Level 3 - Wall: 5.5" 10000 -27500 120 10/08/202001/11/2024 IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 04/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 04/Z4-02 - Level 6 (107")A36 5/8 x 120 69.5 6903 0.048 BPW-6 5657 0.031 CNX-5 14067 0.016 0.098 0.200 0.884 5000 5000 72 A36 7/8 x 120 8 13530 0.003 04/Z4-02 - Level 5 (120")A36 7/8 x 120 112 13530 0.077 BPW-6 5657 0.031 CNX-7 28187 0.013 0.126 0.200 0.884 5000 10000 -A36 1 x 120 8 17671 0.004 04/Z4-02 - Level 4 (120")A36 1 x 120 112 17671 0.103 BPW-7 7688 0.038 CNX-8 29283 0.016 0.161 0.200 0.990 7500 17500 -A36 1 1/4 x 120 8 27612 0.005 04/Z4-02 - Level 3 (120")A36 1 1/4 x 120 112 27612 0.093 BPW-7 7688 0.038 CNX-10 54190 0.017 0.156 0.200 0.976 7500 25000 -B7 1 1/8 x 24 8 46595 0.008 Comments: 4.1 [36.PD] [6"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 7 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing Tension Comp.Level Compression Posts Summary Run: 04/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 107 2x6 DF No.2 [Full Height Post] (1)5156 107 2x6 DF No.2 [Full Height Post] (1)5156 72 2x6 DF No.2 [Bridge Post] (1)5156 72 2x6 DF No.2 [Bridge Post] (1)5156 Totals:Bridge Posts (Tension Chord)5156 5156 10313 0.485 Totals:Full Height Posts (Comp. Chord)5156 5156 24.00 10313 0.107 110 2x6 DF No.2 [Full Height Post] (2)10313 110 2x6 DF No.2 [Full Height Post] (4)20625 Totals:Full Height Posts (Tension Chord)10313 20625 30938 0.162 Totals:Full Height Posts (Comp. Chord)10313 20625 24.00 30938 0.323 110 2x6 DF No.2 [Full Height Post] (2)10313 110 2x6 DF No.2 [Full Height Post] (6)30938 Totals:Full Height Posts (Tension Chord)10313 30938 41250 0.182 Totals:Full Height Posts (Comp. Chord)10313 30938 24.00 41250 0.424 110 2x6 DF No.2 [Full Height Post] (2)10313 110 2x6 DF No.2 [Full Height Post] (10)51563 Totals:Full Height Posts (Tension Chord)10313 41895 52207 0.144 Totals:Full Height Posts (Comp. Chord)10313 51563 24.00 61875 0.404 8Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 04/Z4-02 - Level 6 - Wall: 5.5" -5000 1101 107 04/Z4-02 - Level 5 - Wall: 5.5" 5000 -10000 120 04/Z4-02 - Level 4 - Wall: 5.5" 7500 -17500 120 04/Z4-02 - Level 3 - Wall: 5.5" 7500 -25000 120 10/08/202001/11/2024 IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 05/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 05/Z4-02 - Level 6 (107")A36 5/8 x 120 69.5 6903 0.048 BPW-6 5657 0.031 CNX-5 14067 0.016 0.098 0.200 0.884 5000 5000 72 A36 7/8 x 120 8 13530 0.003 05/Z4-02 - Level 5 (120")A36 7/8 x 120 112 13530 0.077 BPW-6 5657 0.031 CNX-7 28187 0.013 0.126 0.200 0.884 5000 10000 -A36 1 x 120 8 17671 0.004 05/Z4-02 - Level 4 (120")A36 1 x 120 112 17671 0.103 BPW-7 7688 0.038 CNX-8 29283 0.016 0.161 0.200 0.990 7500 17500 -A36 1 1/4 x 120 8 27612 0.005 05/Z4-02 - Level 3 (120")A36 1 1/4 x 120 112 27612 0.093 BPW-7 7688 0.038 CNX-10 54190 0.017 0.156 0.200 0.976 7500 25000 -B7 1 1/8 x 24 8 46595 0.008 Comments: 4.1 [36.PD-35TC] [6"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 9 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing Tension Comp.Level Compression Posts Summary Run: 05/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 107 2x6 DF No.2 [Full Height Post] (1)5156 107 2x6 DF No.2 [Full Height Post] (1)5156 72 2x6 DF No.2 [Bridge Post] (1)5156 72 2x6 DF No.2 [Bridge Post] (1)5156 Totals:Bridge Posts (Tension Chord)5156 5156 10313 0.485 Totals:Full Height Posts (Comp. Chord)5156 5156 24.00 10313 0.107 119 2x6 DF No.2 [Full Height Post] (2)10313 119 2x6 DF No.2 [Full Height Post] (4)20625 Totals:Full Height Posts (Tension Chord)9238 9238 18477 0.271 Totals:Full Height Posts (Comp. Chord)10313 20625 24.00 30938 0.323 119 2x6 DF No.2 [Full Height Post] (2)10313 119 2x6 DF No.2 [Full Height Post] (6)30938 Totals:Full Height Posts (Tension Chord)10313 10957 21270 0.353 Totals:Full Height Posts (Comp. Chord)10313 30938 24.00 41250 0.424 119 2x6 DF No.2 [Full Height Post] (2)10313 119 2x6 DF No.2 [Full Height Post] (10)51563 Totals:Full Height Posts (Tension Chord)10313 10957 21270 0.353 Totals:Full Height Posts (Comp. Chord)10313 51563 24.00 61875 0.404 10Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 05/Z4-02 - Level 6 - Wall: 5.5" -5000 1101 107 05/Z4-02 - Level 5 - Wall: 5.5" 5000 -10000 120 05/Z4-02 - Level 4 - Wall: 5.5" 7500 -17500 120 05/Z4-02 - Level 3 - Wall: 5.5" 7500 -25000 120 10/08/202001/11/2024 IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 06/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 06/Z4-02 - Level 6 (107")A36 5/8 x 120 64 6903 0.044 BPW-6 5657 0.031 CNX-5 14067 0.016 0.094 0.200 0.884 5000 5000 72 A36 7/8 x 120 8 13530 0.003 06/Z4-02 - Level 5 (120")A36 7/8 x 120 112 13530 0.077 BPW-6 5657 0.031 CNX-7 28187 0.013 0.126 0.200 0.884 5000 10000 -A36 1 x 120 8 17671 0.004 06/Z4-02 - Level 4 (120")A36 1 x 120 112 17671 0.103 BPW-7 7688 0.038 CNX-8 29283 0.016 0.161 0.200 0.990 7500 17500 -A36 1 1/4 x 120 8 27612 0.005 06/Z4-02 - Level 3 (120")A36 1 1/4 x 120 112 27612 0.093 BPW-7 7688 0.038 CNX-10 54190 0.017 0.156 0.200 0.976 7500 25000 -B7 1 1/8 x 24 8 46595 0.008 Comments: 4.1 [36.PD] [8"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 11 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing Tension Comp.Level Compression Posts Summary Run: 06/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 107 2x8 DF No.2 [Full Height Post] (1)6797 107 2x8 DF No.2 [Full Height Post] (1)6797 Totals:Bridge Posts (Tension Chord)0 0 0 0.000 Totals:Full Height Posts (Comp. Chord)6797 6797 21.00 13594 0.081 110 2x8 DF No.2 [Full Height Post] (2)13594 110 2x8 DF No.2 [Full Height Post] (3)20391 Totals:Full Height Posts (Tension Chord)13594 20391 33984 0.147 Totals:Full Height Posts (Comp. Chord)13594 20391 21.00 33984 0.294 110 2x8 DF No.2 [Full Height Post] (2)13594 110 2x8 DF No.2 [Full Height Post] (5)33984 Totals:Full Height Posts (Tension Chord)13594 33984 47578 0.158 Totals:Full Height Posts (Comp. Chord)13594 33984 21.00 47578 0.368 110 2x8 DF No.2 [Full Height Post] (2)13594 110 2x8 DF No.2 [Full Height Post] (8)54375 Totals:Full Height Posts (Tension Chord)13594 54375 67969 0.110 Totals:Full Height Posts (Comp. Chord)13594 54375 21.00 67969 0.368 12Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 06/Z4-02 - Level 6 - Wall: 7.25" -5000 1101 107 06/Z4-02 - Level 5 - Wall: 7.25" 5000 -10000 120 06/Z4-02 - Level 4 - Wall: 7.25" 7500 -17500 120 06/Z4-02 - Level 3 - Wall: 7.25" 7500 -25000 120 2x8 DF No.2 [Bridge Post] (1)72 Totals:Full Height Posts (Comp. Chord)6797 6797 21.00 13594 0.081 110 2x8 DF No.2 [Full Height Post] (2)13594 110 2x8 DF No.2 [Full Height Post] (3)20391 Totals:Full Height Posts (Tension Chord)13594 20391 33984 0.147 Totals:Full Height Posts (Comp. Chord)13594 20391 21.00 33984 0.294 110 2x8 DF No.2 [Full Height Post] (2)13594 110 2x8 DF No.2 [Full Height Post] (5)33984 Totals:Full Height Posts (Tension Chord)13594 33984 47578 0.158 Totals:Full Height Posts (Comp. Chord)13594 33984 21.00 47578 0.368 110 2x8 DF No.2 [Full Height Post] (2)13594 110 2x8 DF No.2 [Full Height Post] (8)54375 Totals:Full Height Posts (Tension Chord)13594 54375 67969 0.110 Totals:Full Height Posts (Comp. Chord)13594 54375 21.00 67969 0.368 -5000 1101 107 06/Z4-02 - Level 5 - Wall: 7.25" 5000 -10000 120 06/Z4-02 - Level 4 - Wall: 7.25" 7500 -17500 120 06/Z4-02 - Level 3 - Wall: 7.25" 7500 -25000 120 6797 13594 6797 0.368 10/08/202001/11/2024 IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 07/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 07/Z4-02 - Level 6 (107")A36 5/8 x 120 69.5 6903 0.048 BPW-7 6612 0.022 CNX-5 14067 0.016 0.088 0.200 0.756 5000 5000 72 A36 7/8 x 120 8 13530 0.003 07/Z4-02 - Level 5 (120")A36 7/8 x 120 112 13530 0.077 BPW-7 6612 0.022 CNX-7 28187 0.013 0.116 0.200 0.756 5000 10000 -A36 1 x 120 8 17671 0.004 07/Z4-02 - Level 4 (120")A36 1 x 120 112 17671 0.103 BPW-9 7704 0.038 CNX-8 29283 0.016 0.161 0.200 0.990 7500 17500 -A36 1 1/4 x 120 8 27612 0.005 07/Z4-02 - Level 3 (120")A36 1 1/4 x 120 112 27612 0.093 BPW-9 7704 0.038 CNX-10 54190 0.017 0.156 0.200 0.974 7500 25000 -B7 1 1/8 x 24 8 46595 0.008 Comments: 4.1 [36.PD-35TC-FRT] [6"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 13 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing *Fire Treated* Tension Comp.Level Compression Posts Summary Run: 07/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 107 2x6 DF No.2 [Full Height Post] (1)4434 107 2x6 DF No.2 [Full Height Post] (1)4434 72 2x6 DF No.2 [Bridge Post] (1)4434 72 2x6 DF No.2 [Bridge Post] (1)4434 Totals:Bridge Posts (Tension Chord)4434 4434 8869 0.564 Totals:Full Height Posts (Comp. Chord)4434 4434 27.00 8869 0.124 119 2x6 DF No.2 [Full Height Post] (2)8869 119 2x6 DF No.2 [Full Height Post] (5)22172 Totals:Full Height Posts (Tension Chord)8869 9423 18292 0.273 Totals:Full Height Posts (Comp. Chord)8869 22172 27.00 31041 0.322 119 2x6 DF No.2 [Full Height Post] (2)8869 119 2x6 DF No.2 [Full Height Post] (8)35475 Totals:Full Height Posts (Tension Chord)8869 10347 19216 0.390 Totals:Full Height Posts (Comp. Chord)8869 35475 27.00 44344 0.395 119 2x6 DF No.2 [Full Height Post] (2)8869 119 2x6 DF No.2 [Full Height Post] (12)53213 Totals:Full Height Posts (Tension Chord)8869 10347 19216 0.390 Totals:Full Height Posts (Comp. Chord)8869 53213 27.00 62081 0.403 14Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 07/Z4-02 - Level 6 - Wall: 5.5" -5000 1101 107 07/Z4-02 - Level 5 - Wall: 5.5" 5000 -10000 120 07/Z4-02 - Level 4 - Wall: 5.5" 7500 -17500 120 07/Z4-02 - Level 3 - Wall: 5.5" 7500 -25000 120 10/08/202001/11/2024 IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 08/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 08/Z4-02 - Level 5 (110")A36 7/8 x 120 69.5 13530 0.048 BPW-17-6 14758 0.019 CNX-7 28187 0.017 0.088 0.200 0.739 10000 10000 72 A36 1 x 120 8 17671 0.004 08/Z4-02 - Level 4 (120")A36 1 x 120 112 17671 0.103 BPW-9 7704 0.038 CNX-8 29283 0.016 0.161 0.200 0.990 7500 17500 -A36 1 1/4 x 120 8 27612 0.005 08/Z4-02 - Level 3 (120")A36 1 1/4 x 120 112 27612 0.093 BPW-9 7704 0.038 CNX-10 54190 0.017 0.156 0.200 0.974 7500 25000 -B7 1 1/8 x 24 8 46595 0.008 Comments: 4.1 [35.PD-34TC-FRT] [6"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 15 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing *Fire Treated* Tension Comp.Level Compression Posts Summary Run: 08/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 110 2x6 DF No.2 [Full Height Post] (2)8869 110 2x6 DF No.2 [Full Height Post] (4)17738 72 2x6 DF No.2 [Bridge Post] (2)8869 72 2x6 DF No.2 [Bridge Post] (2)8869 Totals:Bridge Posts (Tension Chord)8869 8869 17738 0.564 Totals:Full Height Posts (Comp. Chord)8869 17738 27.00 26606 0.085 119 2x6 DF No.2 [Full Height Post] (4)17738 119 2x6 DF No.2 [Full Height Post] (6)26606 Totals:Full Height Posts (Tension Chord)10347 10347 20694 0.362 Totals:Full Height Posts (Comp. Chord)17738 26606 27.00 44344 0.395 119 2x6 DF No.2 [Full Height Post] (4)17738 119 2x6 DF No.2 [Full Height Post] (10)44344 Totals:Full Height Posts (Tension Chord)10347 10347 20694 0.362 Totals:Full Height Posts (Comp. Chord)17738 44344 27.00 62081 0.403 16Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 08/Z4-02 - Level 5 - Wall: 5.5" -10000 2261 110 08/Z4-02 - Level 4 - Wall: 5.5" 7500 -17500 120 08/Z4-02 - Level 3 - Wall: 5.5" 7500 -25000 120 10/08/202001/11/2024 IBC - WD*Jurisdiction Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 Product Design Values Report Run: 09/Z4-02 Demand Loads Z4 Products Tension Level Rod Bearing Plate Washer Cinch Nut Summary Le v e l T e n s i o n Co m p o n e n t s ( l b s ) Cu m u l a t i v e T e n s i o n Co m p o n e n t s ( l b s ) Br i d g e B o t t o m H e i g h t ( i n ) Product(s) Le n g t h ( i n ) Ca p a c i t y ( l b s ) El o n g a t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) De f l e c t i o n ( i n ) Pr o d u c t Ca p a c i t y ( l b s ) Tr a v e l + D e f l e c t i o n ( i n ) To t a l D e f l e c t i o n Ma x A l l o w a b l e D e f l e c t i o n Co n t r o l l i n g D e s i g n I n d e x 09/Z4-02 - Level 6 (107")A36 5/8 x 120 69.5 6903 0.048 BPW-6 5657 0.031 CNX-5 14067 0.016 0.098 0.200 0.884 5000 5000 72 A36 7/8 x 120 8 13530 0.003 09/Z4-02 - Level 5 (120")A36 7/8 x 120 112 13530 0.077 BPW-6 5657 0.031 CNX-7 28187 0.013 0.125 0.200 0.884 5000 10000 -A36 1 1/8 x 120 8 22365 0.003 09/Z4-02 - Level 4 (120")A36 1 1/8 x 120 112 22365 0.093 BPW-11 10735 0.035 CNX-9 42337 0.015 0.147 0.200 0.932 10000 20000 -A36 1 3/8 x 120 8 33410 0.004 09/Z4-02 - Level 3 (120")A36 1 3/8 x 120 112 33410 0.092 BPW-17-6 17161 0.016 CNX-11 51093 0.019 0.136 0.200 0.898 10000 30000 -B7 1 1/4 x 24 8 57524 0.008 Comments: 4.2 [36.PD-35TC] [6"] MiTek Specifier v2.5.2009.2101Tuesday, 09 January, 2024 Product Design Values Report 17 10/08/202001/11/2024 IBC - WD*Jurisdiction: Region:United States Number: Address: Name: Customer: HILTON ARCADIA 123 W HUNTINGTON DR, ARCADIA, CA 91007 De s i g n I n d e x Cu m u l a t i v e C o m p r e s s i o n Ca p a c i t y ( l b s ) As s e m b l y L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Ca p a c i t y ( l b s ) Post Selection P o s t L e n g t h ( i n ) Le v e l H e i g h t ( i n ) Fu l l H t . P o s t s Co m p r e s s i o n C h o r d ( l b s ) Br i d g e P o s t s Te n s i o n C h o r d ( l b s ) Fu l l H t . P o s t s Te n s i o n C h o r d ( l b s ) Wall Framing Report Demand Loads Wall Framing Tension Comp.Level Compression Posts Summary Run: 09/Z4-02 (Towards Wall End)(Towards Wall Center) Le v e l T e n s i o n Ca p a c i t y ( l b s ) 107 2x6 DF No.2 [Full Height Post] (1)5156 107 2x6 DF No.2 [Full Height Post] (1)5156 72 2x6 DF No.2 [Bridge Post] (1)5156 72 2x6 DF No.2 [Bridge Post] (1)5156 Totals:Bridge Posts (Tension Chord)5156 5156 10313 0.485 Totals:Full Height Posts (Comp. Chord)5156 5156 18.00 10313 0.107 119 2x6 DF No.2 [Full Height Post] (2)10313 119 2x6 DF No.2 [Full Height Post] (2)10313 Totals:Full Height Posts (Tension Chord)9238 9238 18477 0.271 Totals:Full Height Posts (Comp. Chord)10313 10313 18.00 20625 0.485 119 2x6 DF No.2 [Full Height Post] (2)10313 119 2x6 DF No.2 [Full Height Post] (4)20625 Totals:Full Height Posts (Tension Chord)10313 13535 23848 0.419 Totals:Full Height Posts (Comp. Chord)10313 20625 18.00 30938 0.646 119 2x6 DF No.2 [Full Height Post] (2)10313 119 2x6 DF No.2 [Full Height Post] (6)30938 Totals:Full Height Posts (Tension Chord)10313 13535 23848 0.419 Totals:Full Height Posts (Comp. Chord)10313 30938 18.00 41250 0.727 18Wall Framing ReportTuesday, 09 January, 2024 MiTek Specifier v2.5.2009.2101 09/Z4-02 - Level 6 - Wall: 5.5" -5000 1101 107 09/Z4-02 - Level 5 - Wall: 5.5" 5000 -10000 120 09/Z4-02 - Level 4 - Wall: 5.5" 10000 -20000 120 09/Z4-02 - Level 3 - Wall: 5.5" 10000 -30000 120 10/08/202001/11/2024