HomeMy WebLinkAbout123 W Huntington Dr - 2024 - Hilton Hotel Building D Metal StudSS AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 SW-01 AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 STATEMENT OF GENERAL CONFORMANCE FOR PROJECTS WHICH UTILIZE "DEFERRED SUBMITTAL" PLANS, INCLUDING BUT NOT LIMITED TO SHOP DRAWINGS, PREPARED BY OTHER LICENSED DESIGN PROFESSIONALS AND/OR CONSULTANTS, NOT UNDER RESPONSIBLE CHARGE/DIRECTION OF THE DESIGNATED ARCHITECT/ENGINEER OF RECORD (CITY PERMIT NO. _____________________________________) o THE DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET o THIS DRAWING, PAGE OF SPECIFICATIONS/CALCULATIONS HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARE LICENSED AND/OR AUTHORIZED TO PREPARE SUCH DRAWINGS IN THIS STATE. IT HAS BEEN EXAMINED BY ME FOR: 1.DESIGN INTENT AND APPEARS TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CALIFORNIA CODE OF REGULATIONS AND THE PROJECT SPECIFICATIONS PREPARED BY ME, AND 2.COORDINATION WITH MY PLANS AND SPECIFICATIONS AND IS ACCEPTABLE FOR INCORPORATION INTO THE CONSTRUCTION OF THIS PROJECT. THE STATEMENT OF GENERAL CONFORMANCE SHALL NOT BE CONSTRUED AS RELIEVING ME, OR THE PERSON UNDER WHOSE DIRECT SUPERVISION THESE DOCUMENTS WERE PREPARED, OF OUR RIGHTS, DUTIES, AND RESPONSIBILITIES UNDER APPLICABLE SECTIONS OF THE CALIFORNIA BUILDING CODE. I CERTIFY THAT: ALL DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET THIS DRAWING OR PAGE IS/ARE IN GENERAL CONFORMANCE AND HAVE BEEN COORDINATED SIGNATURE DATE ARCHITECT / ENGINEER IN GENERAL RESPONSIBLE CHARGE OR DELEGATED STRUCTURAL ENGINEER PRINT NAME LICENSE NUMBER EXPIRATION XX X Kenneth D. O'Dell 2024-06-07 S4101 - California 6/30/2025 X 2024-06-10 Kevin Sund 06/14/2024 CONCRETE SLAB, S.S.D. CONCRETE SLAB, S.S.D. 3.8 TYP. 3.8 TYP. 3.6 3.6 3.10 TYP. A DA DG DH DJ DK DL DM DP D1 D2 D3.1 D5 D7 D8.1 D11.5 D12 D8.1 D12 DC.5 DF.5 D11.5D7 D5.5 DD.5 DE.5 DF DG.5 DH.5 DI.5 DK.5 DL.5 DG DH DJ DK DL DM DP DF.5 DF DG.5 DH.5 DI.5 DK.5 DL.5 DA DC.5 DD.5 DE.5 DB.4DB.4 F3 F2 F4 F3F5 F3 F3 F3 F4 CONCRETE SLAB ON GRADE PER NOTE #10 F2 CC5 CC5CC3 CC3 CC3 CC3 F3 F3 F3 SEE CS PLAN SHEETS FOR MORE INFORMATION CC1 CC4 F2 F2 F2 F2 CC1 SIM CC1 SIM CC1 SIM CC1 SIM CC1 SIM CC1 CC1 CC6 CC1 F2 F210 " CC3 CC3 10 " CC1 CC1 CC1 F4 1'- 6 " 1'- 6 " F6 4'-0"4'-0" 1' - 2 " F4 4'- 0 " 5'-0"5'-0" 4' - 0 " 30" THK CONC MAT SLAB W/ #8 @ 12"OC EA WAY TOP AND #9 @ 10" EW BOTT 6'-0" 6'-0" 1'- 6 " 2'-0" 2'- 6 " F1 F1 F1 3' - 0 " 3' - 0 " 3'-0" F1 2'-6" CC1 CC1 SIM F1 F1 WF2 WF2 WF 2 WF 2 WF 1 WF3 WF3 WF4 WF 1 WF 5 WF 3 WF1 WF 1 8" CMU W/ #5 @ 16"OC VERT EF AND #4 @ 16"OC HORIZ EF CC4 F4 CC4 F4 CC4 F4 CC4 F4 CC4 F4 CC4 F4 CC4 12" WIDE x18" DEEP CONT FTG W/ (2)-#5 T&B , TYP UNO AT PERIMETER WF 2 WF 2 F1 F1 F1 WF 2 CONC SLAB CONTROL & CONSTRUCTION JOINTS PER 11 S4.1 1'-6" THK ELEV PIT SLAB W/ #6 @ 12"OC EW T&B WF 1 C3 C3 C3 F1C3 C3 F1C3 2'-6" C3 F1C3 C3 F1C3 C3 C3 1/2" VERT JOINT BTWN CONC & CMU, TYP F1C3 C3 C3 C3 C3 C3 C3 C3 54 ' - 0 " 40 ' - 0 " 12'-0" WIDE x36" DEEP CONC FTG W/ (12)-#9 LONG T&B & #9 @ 12"OC TRANS T&B ALIGN WEST FACE OF WF2 FTG W/ F4 FTG, TYP 3 1 / 8 " 12'-0" WIDE x36" DEEP CONC FTG W/ (12)-#9 LONG T&B & #9 @ 12"OC TRANS T&B F1C3 F1 C3 3'-5" WF6 C3 F1C3 C3 C7 C7 C7 C7 WF1 19 ' - 2 1 / 8 " 3 1/8 F/O COL 19 ' - 0 7 / 8 " 4'-4" 13 ' - 2 " 1'- 1 1 / 2 " 5'-7 3/4" 4' - 3 3 / 8 " 9' - 7 " 3 1/2"9'-2" 18'-10 3/8" 14'-9 3/8" 3'-6"4'-3 3/8"6'-5"8 3/4" 7'-0" 13 ' - 3 " 13 ' - 0 " CC2 CC2 CC2 CC2 CC2 CC2 CC2 10 ' - 1 0 3 / 4 " 3' - 1 1 1 / 2 " 6' - 1 1 1 / 4 " 1'- 6 1 / 2 " 6'- 0 1 / 2 " 6" 35'-6 1/4" 4" 9" 3'-8 1/2" CC1 F3 F3 5' - 0 " 5'-0" CMU WALL AND FTG PER 19 CS3.2 F1C3 ALIGN WEST FACE OF F1 FTG WITH F2 FTG T/O FTG = -2'-3" T/O FTG = -2'-3" T/O FTG = -2'-3" T/O FTG = -1'-9" T/O FTG = -1'-0" T/O FTG = -5'-0"T/O FTG = -4'-6" T/O FTG = -2'-3" T/O FTG = -2'-3"T/O FTG = -2'-3" T/O FTG = -2'-3" T/O FTG = -2'-3" T/O FTG = -2'-3" T/O FTG = -2'-3" T/O FTG = -2'-3"T/O FTG = -3'-9" T/O FTG = -1'-9" TRANSFORMER T/O FTG = -3'-9" UP UP UP UP AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 FIRST FLOOR INT. & EXTERIOR WALL PLAN SYMBOLS & LEGENDS INTERIOR WALL STUDS SCHEDULE SW-02 KEY PLAN EXTERIOR WALL STUDS SCHEDULE 2024-06-10 Kevin Sund 06/14/2024 A DA DG DH DJ DK DL DM DP D1 D2 D3.1 D5 D7 D8.1 D11.5 D12 D8.1 D12 DC.5 DF.5 D11.5D7 D5.5 DD.5 DE.5 DF DG.5 DH.5 DI.5 DK.5 DL.5 DG DH DJ DK DL DM DP DF.5 DF DG.5 DH.5 DI.5 DK.5 DL.5 DA DC.5 DD.5 DE.5 DB.4 DC DC D3 D3 D3 5" S E I S M I C SE P A R A T I O N W8 x 3 5 W10x68 W1 0 x 4 5 W10x45 HSS5x5x3/8 BRACE ABOVE W5 x 1 9 W1 4 x 2 6 W1 4 x 2 6 W1 0 x 6 8 W1 0 x 6 8 W10x33 W10x33 W1 0 x 4 5 W10x45 W10x45 W1 0 x 4 5 W10x33 W10x33 W10x88 W1 0 x 6 8 W1 0 x 6 8 W8 x 3 5 W8 x 3 5 W8 x 3 5 W8 x 3 5 W8 x 3 5 W8 x 3 5 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 4 x 2 6 W1 4 x 2 6 W1 0 x 6 8 W1 0 x 6 8 W1 0 x 3 3 W1 0 x 3 3 W10x68W10x33W10x33 W10x33 SEE CS PLAN SHEETS FOR MORE INFORMATION W1 0 x 3 3 W1 0 x 3 3 W10x68W10x68 W10x68W10x68W10x33 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W10x68 W10x68 W10x33 W10x33 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W10x68 W10x68 W5 x 1 9 W1 2 x 2 2 W1 0 x 3 3 W10x33 W1 0 x 4 5 W1 0 x 4 5 W1 0 x 4 5 W1 0 x 4 5 W10x33 W1 0 x 6 8 W10x45 W10x33 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 10 " 10 " W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W10x45W10x45 W10x45 W10x45 W10x45 TY P A T R O O F D4 D4 T/O SLAB EL=13'-0" W1 0 x 3 3 W1 0 x 6 8 5" W10x33 W10x33 W10x68 W1 0 x 3 3 W1 0 x 3 3 W10x33 W1 0 x 6 8 W10x33 W10x33W10x33 C7 C7 SB4 W10x33 W1 0 x 3 3 W10x33 W10x33 5" D3 T/O SLAB EL=10'-0" T/O SLAB EL=9'-7" 5" 14"x14" MAX OPNG PER 9 CS4.4 W10x68 W10x33 W1 0 x 3 3 W14x43 W5x19 W5x19W5x19W5x19W5x19W5x19W5x19W5x19W5x19 W5x19 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W14x26 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W1 0 x 3 3 W10x68 2'-0" 2'-0"1'-0" 2 S5.2 TYP AT STEEL MOMENT CONN TO COL 1'-0"1'-0" 1'-0" T/O SLAB EL=12'-3" W8 x 3 5 W8x35W8x35W8x35 W8x35 W8 x 3 5 2' - 0 " 2'- 0 " L6x6x1/2 LEDGER L6x6x1/2 LEDGER L6x6x1/2 LEDGER L6x6x1/2 LEDGER L6x6x1/2 LEDGER C7 C7 1 S5.2 TYP AT STEEL TO CONC CONN, UNO L6x6x1/2 LEDGER W1 0 x 3 3 C8x18.7 HEADER C8x18.7 HEADER ld ADD'L (2)-#6 BARS WELDED TO BACK OF EMBED PL ld ADD'L (2)-#6 BARS WELDED TO BACK OF EMBED PL W1 0 x 3 3 W10x33 W12x58W5 x 1 9 W5 x 1 9 W5 x 1 9 W5 x 1 9 W5 x 1 9 W5 x 1 9 W5 x 1 9 W12x58W12x58 W5 x 1 9 C3 1'- 0 " AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 2ND FLOOR INT. & EXTERIOR WALL PLAN SW-03 SYMBOLS & LEGENDS EXTERIOR WALL STUDS SCHEDULE INTERIOR WALL STUDS SCHEDULE KEY PLAN 2024-06-10 Kevin Sund 06/14/2024 LL EM EM EM EM EM EM D1 D2 D3.1 D5 D7 D8.1 D11.5 D12 DA DC.5 DF.5 DJ DM DP DL DK DH DG DF DE.5 D3 D4 D6 D8 D10 D11 DC DD DE 2 A5.03 1 A5.03 1 A5.04 2 A5.04 A3.13 2 A3.08 2 A3.07 2 Z_A3.06 2 A3.12 4 A3.10A 1 A3.09 2 A3.11A 1 15'-11"49'-6"19'-0" 12 ' - 8 " 8' - 4 " 3' - 6 " 17 ' - 6 " 14 ' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 7' - 0 " 9' - 3 " 9'-2"24'-1 1/2"18'-0"7'-0"21'-0"15'-11"49'-6"19'-0" 6' - 0 " 31 ' - 6 " 12 ' - 8 " 11 ' - 1 0 " 17 ' - 6 " 14 ' - 0 " DL.5 DK.5 DJ.5 DH.5 DG.5 D5.5 A3.07 4 DD.5 DB.4 POOL EQUIP. D 004 ELEC. D 005 MDF RM D 005A RISER RM. D 006 DOMESTIC WATER PUMP ROOM D 132 SERVICE CORRIDOR D 116 BOH CORRIDOR D 103 ELEV. LOBBY D 111 LOBBY D 105 BANQUET STORAGE D 112 PREFUNCTION D 113 KITCHEN HOOD DRY STORAGE D 107 STAGING D 117 KITCHEN D 104 W D 110 M D 109 FITNESS CENTER D 102 COURTYARD D 126 BANQUET ROOM #2 D 115 14' - 4" A.F.F. GYP. BD. 13' - 0" A.F.F. GYP. BD. 14' - 4" A.F.F. GYP. BD. 14' - 6" A.F.F. GYP. BD. 12' - 0" A.F.F. GYP. BD. BANQUET ROOM #1 D 114 12' - 0" A.F.F. GYP. BD. 14' - 6" A.F.F. GYP. BD. 12' - 0" A.F.F. GYP. BD. 12' - 0" A.F.F. GYP. BD. 9' - 0" A.F.F. GYP. BD. 9' - 6" A.F.F. GYP. BD. 9' - 6" A.F.F. GYP. BD. 9' - 0" A.F.F. GYP. BD. 9' - 0" A.F.F. GYP. BD. 10' - 0" A.F.F. GYP. BD. 8' - 6" A.F.F. GYP. BD. 13' - 0" A.F.F. GYP. BD. 14' - 6" A.F.F. GYP. BD. 9' - 6" A.F.F. GYP. BD. 9' - 0" A.F.F. GYP. BD. 8' - 0" A.F.F. ACT1 8' - 0" A.F.F. GYP. BD. 8' - 0" A.F.F. GYP. BD. OPEN TO SKY EXP. TO FLOOR ASSEMBLY EXP. TO FLOOR ASSEMBLY 8' - 0" A.F.F. GYP. BD. 8' - 0" A.F.F. ACT1 9' - 0" A.F.F. ACT4 SHAFT ABOVE IN CEILING EXP. TO FLOOR ASSEMBLY A3.16 5 8' - 0" A.F.F. ACT1 8' - 0" A.F.F. ACT2 10' - 0" A.F.F. GYP. BD. TYP. TYP. 13' - 0" A.F.F. GYP. BD. TYP. TYP. EXP. TO FLOOR ASSEMBLY TYP. TYP. TYP. TYP. 13' - 0" A.F.F. GYP. BD. TYP. 12' - 0" A.F.F. GYP. BD. HALL D 129 8' - 0" A.F.F. ACT1 WARMING KITCHEN/ SERVING SETUP D 127 CLOSER PANEL TO TOP OF WIC SHAFT ABOVE IN CEILING 12' - 0" A.F.F. GYP. BD. SHAFT ABOVE 13' - 10" A.F.F. GYP. BD. 13' - 10" A.F.F. GYP. BD.TYP. TYP. 5" SEISMIC GAP WITH SEISMIC COVER 10' - 0" A.F.F. GYP. BD. 8' - 0" A.F.F. ACT210' - 0" A.F.F. GYP. BD. 7' - 2" A.F.F. GYP. BD. 8' - 0" A.F.F. ACT1 A6.12 1A 10' - 0" A.F.F. GYP. BD. 10' - 0" A.F.F. GYP. BD. 10' - 0" A.F.F. GYP. BD. 1.2.3.4.5.6. SEE UNIT PLANS A3.20 - A3.60 SERIES FORTYPICAL UNIT RCP LAYOUTS.ACCESS PANELS WHERE REQUIRED. PAINTFINISH TO MATCH ADJACENT WALL FINISHU.O.N.PAINT HVAC GRILLES, ACCESS PANELS, ETC.TO MATCH ADJACENT FINISHES U.O.N.FIRE SPRINKLER SYSTEM DEFERREDSUBMITTAL.SEE ELECTRICAL DRAWINGS FOR EMERGENCYLIGHTING & LIFE SAFETY DEVICES.SEE ELECTRICAL DRAWINGS FOR LIGHT TAGS,FIXTURE ZONING & ELECTRICAL DEVICELOCATIONS. SHEET NOTES7.8.9.SEE MECHANICAL DRAWINGS FOREXHAUST/SUPPLY/RETURN FAN INFORMATION .PROVIDE SEISMIC CONTROL JOINT AT ALL GYP.BD. CEILING AREAS EXCEEDING 2,500SF. SEEDETAILS ON A8.61.EXIT SIGN SHOWN IN CORRIDOR SHALL BEPROVIDED WITH LOW EXIT SIGN PER CBC1013.7, SEE ELECTRICAL PLANS FORINFORMATION AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 FIRST FLOOR SOFFIT PLAN SYMBOLS & LEGENDS INTERIOR WALL STUDS SCHEDULE SW-04 KEY PLAN EXTERIOR WALL STUDS SCHEDULE 2024-06-10 Kevin Sund 06/14/2024 TYPICAL STUD INTERSECTION SCREW DETAILS 2 3 5 8 TYPICAL SCREW PENETRATION 16 12 11 13MULTIPLE STEEL STUDS TO TRACK STEEL STUD TO TRACK CONN. TYPICAL STEEL STUD WALL FRAMING ELEVATION SILL AT 12'-6" MAX. OPENING IN EXT. STEEL STUD WALL SILL AT 4'-6" MAX. OPENING IN EXT. STEEL STUD WALL BUILT-UP BEAM /COLUMN 25 HEADER AT 4'-6" MAX. OPENG. IN EXT. STEEL STUD WALL HEADER AT 12'-6" MAX. OPENG. IN EXT. STEEL STUD WALL INT. STEEL BOTTOM TRACK ANCHORAGE 24 1823 17 16 22 21 STEEL STUD BKOCKING AND STRAP HEADER SIZING TABLE TYPICAL COLUMN AT ENTRY CONC. COL. AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 SW-06 2024-06-10 Kevin Sund 06/14/2024 110 6 7 8 15 14 12 11 19 17 16 25 22 23 NON-BRG WALL FRAMING HEADER FRAMING @ LOAD-BEARING WALL HEADER @ NON-BEARING WALL MULTI-STUD PACKS HOLE REINFORCEMENT TRACK SPLICEBLOCKING PANEL BEAM TO POST 21 BEAM TO POST JOIST/BEAM STIFFENERS EXTERIOR STUD WALL AT CONC.BRACKING DETAIL DETAIL AT PARAPET STL. COL. IN STEEL STUD WALL 18 FULL HIGH NON-BRG WALL TO METAL DECKSOFFIT TO METAL DECK INTERIOR STUD WALL AT CONC. 24 1TYP. EXT. METAL STUD WALL TO STL. BM TYP. SLOTTED TRACK AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 SW-07 2024-06-10 Kevin Sund 06/14/2024 4 51516TYP. INTERIOR METAL STUD WALL AT CONC. SLAB 1 2 FAST TOP CLIPS (FTC-5)-1 3 9 7 8 STUD CONN. W/ FCSC 5-1/2" CLIPS STUD CONN. W/ FCEC 8" OR 10" CLIP METAL WALL TO FTG AT POP-OUT TYP. EXT. METAL STUD WALL AT CONC. SLAB&FTG 13TYP. EXTERIOR METAL STUD WALL AT CONC. SLAB STUD TO CONCRETE SLAB 10 METAL WALL TO STL. AT POP-OUT TYP. EXTERIOR METAL STUD TO W BEAM TYP. METAL STUD TO TOP OF BEAM DETAIL METAL WALL TO CONC. SLAB 611 12TYP. EXT. METAL STUD WALL AT CONC. SLAB&FTGTYP. EXT. METAL STUD WALL AT CONC. SLAB&FTG 14 AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 SW-08 2024-06-10 Kevin Sund 06/14/2024 SOFFIT/SUSPENDED CEILING JOIST FRAMING 1 2 35 6 4 DETAIL DETAIL AT ENTRY SOFFIT 7DETAIL TYP. EXT. METAL STUD WALL AT CONC. SLAB&FTG DETAIL TYP. EXT. METAL STUD WALL AT CONC. SLAB&FTG AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 SW-09 2024-06-10 Kevin Sund 06/14/2024 24 1WALL SECTION WALL SECTION 3 WALL SECTION WALL SECTION AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 SW-10 2024-06-10 Kevin Sund 06/14/2024 TYP. EXT. METAL STUD WALL SECTION 1 TYP. EXT. EDGE OF ROOF DECK DETAIL 2 TYP. SECTION 3 AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 SW-11 2024-06-10 Kevin Sund 06/14/2024 2 TYP. SECTION 1 TYP. SECTION AQX ENGINEERING INC. 1520 Brookhollow, Suite #45 Santa Ana, CA 92705 Off. (714) 662-0510 Fax. (714) 662-1050 www.aqxeng.com ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE AQX AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE AQX HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. BUILDING D 1 PLAN CHECK CORRECTION 06/01/2024 SW-12 2024-06-10 Kevin Sund 06/14/2024 06/14/2024