Loading...
HomeMy WebLinkAbout123 W Huntington Dr - 2024 - Hilton Hotel EBM SystemsEBM0.1 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com GENERAL NOTES 1.VERIFICATION: VERIFY ALL DIMENSIONS, ELEVATIONS & SITE CONDITIONS BEFORE STARTING WORK. NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 2.CONFLICTS: NOTES & DETAILS ON THE DRAWINGS TAKE PRECEDENCE OVER THE GENERAL NOTES & TYPICAL DETAILS IN CASE OF CONFLICT. OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH ANY WORK INVOLVED. 3.SUBSTITUTIONS: PROVIDE MANUFACTURER'S APPROVED PRODUCT EVALUATION REPORTS & A LIST OF ALL PROPOSED SUBSTITUTIONS TO THE ENGINEER FOR REVIEW & WRITTEN APPROVAL BEFORE FABRICATION. 4.SIMILAR WORK: WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, SUCH DETAILS SHALL BE THE SAME AS FOR SIMILAR WORK SHOWN ON THE DWGS. 5.CONSTRUCTION METHODS AND PROJECT SAFETY: THE CONTRACT DRAWINGS & SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE METHODS, PROCEDURES OR SEQUENCES OF CONSTRUCTION. TAKE NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF THE STRUCTURE DURING CONSTRUCTION. NEITHER THE OWNER NOR ARCHITECT / ENGINEER WILL ENFORCE SAFETY MEASURES OR REGULATIONS. CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND BRACING. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. 6.CHANGES TO DRAWINGS: OBTAIN PRIOR WRITTEN APPROVAL. 7.OPTIONS: OPTIONS ARE FOR THE CONTRACTOR'S CONVENIENCE. HE SHALL BE RESPONSIBLE FOR ALL CHANGES NECESSARY IF HE CHOOSES AN OPTION AND SHALL COORDINATE ALL DETAILS. THE COST OF ADDITIONAL DESIGN WORK NECESSITATED BY THE SELECTION OF AN OPTION SHALL BE BORNE BY THE CONTRACTOR. 8.ADDITIONAL DESIGN: THE COST OF ADDITIONAL DESIGN WORK DUE TO ERRORS OR OMISSIONS IN CONSTRUCTION SHALL BE BORNE BY THE CONTRACTOR. 9.COORDINATION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES & SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH THE WORK. 10.EXISTING CONDITIONS: ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE ENGINEERS SO THAT PROPER REVISIONS MAY BE MADE. MODIFICATIONS OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER. 11.EXISTING STRUCTURE: ADEQUACY OF EXISTING STRUCTURE TO SUPPORT THE IMPOSED LOADS SHALL BE VERIFIED BY THE PARENT BUILDING STRUCTURAL ENGINEER OF RECORD OR STRUCTURAL ENGINEER FOR THE PROJECT. 12.WATERPROOFING: GENERAL CONTRACTOR OR DESIGNATED WATERPROOF IS FULLY RESPONSIBLE FOR WEATHERPROOFING ALL PENETRATIONS IN ROOF AND/OR WALL COVERINGS DUE TO INSTALLATION OF NEW ASSEMBLIES. 13.COMPLETION: UPON COMPLETION OF THIS SCOPE OF WORK, IT SHALL BECOME THE RESPONSIBILITY OF THE GENERAL CONTRACTOR OR OWNER TO PROTECT THIS WORK FROM ANY DAMAGE DURING THE REMAINDER OF CONSTRUCTION OF THIS PROJECT. 14.MODIFICATIONS: ANY MODIFICATIONS TO THE INSTALLED SYSTEM SHALL BE PERFORMED ONLY AND EXCLUSIVELY BY THE INSTALLING CONTRACTOR RESPONSIBLE FOR THE SYSTEM. MODIFICATIONS MADE BY ANY OTHER PARTY TRANSFERS LIABILITY TO THAT PARTY MAKING THE MODIFICATIONS. DESIGN STANDARDS & CODES: 1.ALL MATERIALS, WORK & DESIGN SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: ·2022 CALIFORNIA CODE OF REGULATIONS (CCR) - TITLE 24 ·2022 CALIFORNIA BUILDING CODE (CBC) ·2021 INTERNATIONAL BUILDING CODE (IBC) ·ASCE 7-16 MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDING AND OTHER STRUCTURES ·CAL/OSHA INDUSTRY SAFETY ORDERS - TITLE 8 INDUSTRIAL RELATIONS ··ARTICLE 5 - WINDOW CLEANING ··ARTICLE 6 - POWERED PLATFORMS AND EQUIPMENT FOR BUILDING MAINTENANCE ·FEDERAL OSHA STANDARDS - 29 CFR 1910.66 POWERED PLATFORMS FOR BUILDING MAINTENANCE ·ASME A120.1-2014 - SAFETY REQUIREMENTS FOR POWERED PLATFORMS AND TRAVELING LADDERS AND GANTRIES FOR BUILDING MAINTENANCE ·ANSI/ASSP Z359 (LATEST REVISION) SAFETY REQUIREMENTS FOR PERSONAL FALL ARREST SYSTEMS, SUBSYSTEMS AND COMPONENTS ·APPLICABLE PROVISIONS OF NEMA AND THE NATIONAL ELECTRIC SAFETY CODE STEEL NOTES: 1.ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (A.I.S.C.). 2.THE FOLLOWING STEEL MATERIAL SHALL CONFORM TO THEIR RESPECTIVE ASTM STANDARDS NOTED: 2.A.ANCHOR RODS A307 2.B.OTHER SHAPES A36 2.C.PLATES A572 GR 50 2.D.HSS TUBE A500 GR B OR GR C 2.E.WIRE ROPE A492 (STAINLESS STEEL) ALUMINUM NOTES: 1.ALL STRUCTURAL ALUMINUM SHALL BE FABRICATED AND ERECTED IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (A.I.S.C.). 2.THE FOLLOWING ALUMINUM MATERIAL SHALL CONFORM TO THEIR RESPECTIVE ASTM STANDARDS NOTED: 2.A.PLATES 6161-T6 B308/B308M 2.B.HSS 6061-T6 B308/B308M WELDING NOTES: 1.ALL WELDING IS TO COMPLY WITH AWS STANDARDS AND IS TO BE DONE BY WELDERS CERTIFIED FOR THE TYPE OF WELDING TO BE PERFORMED AS REQUIRED 2.ALL WELDING IS TO BE DONE BY ELECTRIC ARC PROCESS WITH E70XX ELECTRODES, E70-T4 ELECTRODE IS NOT ALLOWED. 3.ALL EXPOSED FIELD WELDS SHALL BE APPLIED WITH A COLD GALVANIZING SPRAY OR EQUIVALENT CORROSIVE-RESISTANT SUBSTANCE. HARDWARE NOTES: 1.ALL BOLTED CONNECTIONS SHALL BE TURN-OF-NUT TIGHTENING. BOLTS SHALL BE INSTALLED IN THE HOLES OF THE CONNECTION AND BROUGHT TO A SNUG-TIGHT CONDITION. SNUG TIGHT AS DEFINED AS THE TIGHTNESS THAT EXIST WHEN THE PLIES OF THE JOINT ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF A PERSON USING AN ORDINARY SPUD WRENCH. AFTER OBTAINING A SNUG-TIGHT CONDITION, TURN EACH NUT OF THE CONNECTION AN ADDITIONAL 13 TURN. 2.ALL FALL PROTECTION COMPONENTS & HARDWARE SHALL BE STAINLESS STEEL OR GALVANIZED. EXTERIOR BUILDING MAINTENANCE DESIGN NOTES: 1.A 42" PARAPET IS REQUIRED AT ALL: A.SCHEDULED MAINTENANCE WORK AREAS WHERE A WORKER MUST PASS WITHIN 6' OF A ROOF EDGE. B.EBM EQUIPMENT LOCATIONS. C.LOCATIONS WHERE A WORKER MUST PASS WITHIN 6' OF A FALL HAZARD EXCEEDING 30" ON A ROUTINE BASIS. D.SKYLIGHTS AND OTHER FLOOR OPENINGS. 2.EBM EQUIPMENT MAY NOT BE TRANSFERRED BETWEEN ROOF LEVELS AND MUST BE STORED AT THE LEVEL IN WHICH IT WILL BE USED 3.PERMANENT ACCESS IS REQUIRED TO ANY ROOFTOP WHERE EBM EQUIPMENT, MECHANICAL EQUIPMENT, SOLAR PANELS AND/OR ROOF DRAINS ARE PRESENT. 4.POWER LINES MUST NOT PASS WITHIN 15' OF A BUILDING FACADE WHERE EBM EQUIPMENT IS BEING UTILIZED ON A ROUTINE BASIS. 5.LAG SCREWS MAY NOT BE USED IN NEW OR REPLACEMENT INSTALLATIONS. EBM SYSTEM DESCRIPTION AT THE BUILDING PERIMETER, GROUND-RIGGED POWERED PLATFORMS SUSPENDED BY PORTABLE OUTRIGGER SYSTEMS SHALL BE USED TO ACCESS THE FACADE FOR EXTERIOR WINDOW CLEANING. THE POWERED PLATFORMS ALONG WITH ANY ADDITIONAL RIGGING EQUIPMENT SHALL BE PROVIDED BY THE WINDOW CLEANING CONTRACTOR ON AN AS-NEEDED BASIS AS SPECIFIED ON THE OPERATING PROCEDURES OUTLINE SHEET (OPOS). WINDOW CLEANING AT WINDOWS BELOW 48' FROM GRADE OR TERRACE SHALL BE PERFORMED USING WATER-FED EXTENSION POLES AND/OR PORTABLE LADDERS WHERE POSSIBLE. UNSCHEDULED BUILDING MAINTENANCE (I.E. PAINTING, CAULKING, WINDOW REPLACEMENT, ETC.) SHALL BE DONE USING EITHER BUILT-UP SCAFFOLDING SYSTEMS, AERIAL LIFTS, TIE-BACK ANCHORS OR OTHER EBM EQUIPMENT SHOWN EXTERIOR BUILDING MAINTENANCE HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 SHEET INDEX EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 3 08/21/2024 STATEMENT OF GENERAL CONFORMANCE FOR PROJECTS WHICH UTILIZE "DEFERRED SUBMITTAL" PLANS, INCLUDING BUT NOT LIMITED TO SHOP DRAWINGS, PREPARED BY OTHER LICENSED DESIGN PROFESSIONALS AND/OR CONSULTANTS, NOT UNDER RESPONSIBLE CHARGE/DIRECTION OF THE DESIGNATED ARCHITECT/ENGINEER OF RECORD (CITY PERMIT NO. _____________________________________) o THE DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET o THIS DRAWING, PAGE OF SPECIFICATIONS/CALCULATIONS HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARE LICENSED AND/OR AUTHORIZED TO PREPARE SUCH DRAWINGS IN THIS STATE. IT HAS BEEN EXAMINED BY ME FOR: 1.DESIGN INTENT AND APPEARS TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CALIFORNIA CODE OF REGULATIONS AND THE PROJECT SPECIFICATIONS PREPARED BY ME, AND 2.COORDINATION WITH MY PLANS AND SPECIFICATIONS AND IS ACCEPTABLE FOR INCORPORATION INTO THE CONSTRUCTION OF THIS PROJECT. THE STATEMENT OF GENERAL CONFORMANCE SHALL NOT BE CONSTRUED AS RELIEVING ME, OR THE PERSON UNDER WHOSE DIRECT SUPERVISION THESE DOCUMENTS WERE PREPARED, OF OUR RIGHTS, DUTIES, AND RESPONSIBILITIES UNDER APPLICABLE SECTIONS OF THE CALIFORNIA BUILDING CODE. I CERTIFY THAT: ALL DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET THIS DRAWING OR PAGE IS/ARE IN GENERAL CONFORMANCE AND HAVE BEEN COORDINATED SIGNATURE DATE ARCHITECT / ENGINEER IN GENERAL RESPONSIBLE CHARGE OR DELEGATED STRUCTURAL ENGINEER PRINT NAME LICENSE NUMBER EXPIRATION XX X Kenneth D. O'Dell 2024-08-29 S4101 - California 6/30/2025 X VFD 42" C L R 30"C L R 42"C L R 30"C L R 42"C L R 30" C L R 30"C L R 42" C L R 30"C L R 42"C L R 30"C L R 42"C L R 42"CLR 30"CLR 30"CLR 42"CLR 30"C L R 42" C L R 30"C L R 42" C L R 1 A B C C.3 C.4 D 0.6 2 3 4 5 6 7 7 8 9 10 11 12 136.7 7.3 0.5 2.5 3.5 4.5 5.5 6.5 C.6 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 A.1 1.5 2% MIN. 2% MIN. 2%MIN . 2% MIN. 2% MIN. 2% MIN . 2%MIN . 2% MIN . 2% MIN.2% MIN. 2%MIN . 2% MIN . 2%MIN . 2%MI N . 2% MIN . 2% MI N . 2% MIN . DN 30" C L R FRO N T 42" C L R 30" C L R FR O N T 42" C L R 30" C L R FRO N T 42" C L R 30" C L R 42" C L R 30" C L R 42" C L R 30"C L R 42"CLR 30"CLR FRONT DN FRONT 42" CLR 30" CLR 42" C L R 30" C L R FRO N T 42"C L R 30" C L R FRO N T FRO N T 42 " C L R 30 " C L R FR O N T 42" C L R 30" C L R 13 A B C C.3 C.4 13.4 D1 D2 D5 D7 D8.1 D8.1 D11.5 D12 D12 DA DA DC.5 DJ DM DP DL DK DH DG DF DE.5 D3 D4 D6 D8 D10 D10 D11 D11 DC DC DD DD DE DN DB DB DD.2 D11.9 D5.5 ELEV. MACHINE ROOM ST-D2.7 DD.5 DB.42% MIN. 2% MIN. 2% MI N . 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MI N . D700 2% MIN. 2% MI N . 60' - 6 1/8" H.P. 59' - 9" L.P. 59' - 9" L.P. 2% MI N . R 1 7 ' - 4 " 2% MI N . 2% MIN. 9' - 0 " 9'- 0 " 8M 8M 8M 8M 12 ' - 0 " 9'- 6 " 7'- 0 " 7'- 0 " 7'- 0 " 1M 1M 1M 1M 14'-718" HB HB HB HB HB HBHB 7'- 4 " HBHB HBHB 1M HB HB HB HB HB HB HB HB HB 1 1/16"=1'-0" OVERALL ROOF PLAN - BUILDING C & D CANOPY AT LEVEL 1 EBM1.0 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com N HATCH LEGEND WATER FED POLE OPERATIONS ZONE (GROUND LEVEL & LOW ROOF) HIGH/LOW LEVEL ROOF TOP BOOM LIFT OPERATIONS ZONE (GROUND LEVEL) SWING STAGE OPERATIONS ZONE (ROOF TOPS & GROUNDLEVEL) 2 1 08/21/2024 VFD 42" C L R 30 " C L R 42 " C L R 30" C L R 42" C L R 30" C L R 30" C L R 42 " C L R 30"C L R 42"C L R 30" C L R 42"C L R 42"CLR 30"CL R 30"CLR 42"CL R 30 " C L R 42" C L R 30" C L R 42" C L R 1 A B C C.3 C.4 D 0.6 2 3 4 5 6 7 7 8 9 10 11 12 136.7 7.3 0.5 2.5 3.5 4.5 5.5 6.5 C.6 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 A.1 1.5 2% MIN. 2% MIN. 2%MIN . 2% MIN. 2% MIN. 2% MIN . 2%MIN . 2% MIN . 2% MIN.2% MIN. 2%MIN . 2% MIN . 2%MIN . 2%MI N . 2% MIN . 2% MI N . 2% MI N . DN FRONT 42" CLR 30" CLR 42 " C L R 30" C L R FR O N T FR O N T 42 " C L R 13 A B C C.3 C.4 13.4 D1 D2 D5 DA DC.5 DE.5 D3 D4 DC DD DB DD.2 D5.5 9' - 0 " 9' - 0 " HBHB HBHB LOW LEVEL ROOF, PERMANENT ACCESS REQUIRED FOR ALL GROUND WINDOW WASHING OPERATIONS, SEE EBM1.2 FOR ACCESS DESIGN LAYOUT ACCESS PATH REQUIRED FOR ALL GROUND WINDOW WASHING OPERATIONS. SEE DETAIL 1/EBM3.2 HB HB HB HB HB HB HB HB HB 1 3/32"=1'-0" ROOF PLAN - BUILDING C 1 EBM2.0 3 EBM2.1 2 EBM2.0 4 EBM2.1 2 EBM2.1 CANOPY AT LEVEL 1 1 EBM2.1 EBM1.1 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com N HATCH LEGEND WATER FED POLE OPERATIONS ZONE (GROUND LEVEL & LOW ROOF) HIGH/LOW LEVEL ROOF TOP BOOM LIFT OPERATIONS ZONE (GROUND LEVEL) SWING STAGE OPERATIONS ZONE (ROOF TOPS & GROUNDLEVEL) 08/21/2024 42 " C L R 30 " C L R 42 " C L R 30 " C L R 30 " C L R 30 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 11 12 13 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 2% MI N . DN 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 30 " C L R 42"CLR 30"CLR FRONT DN FRONT 42" CLR 30" CLR 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R 13 A B C C.3 C.4 13.4 D1 D2 D5 D7 D8.1 D8.1 D11.5 D12 D12 DA DA DC.5 DJ DM DP DL DK DH DG DF DE.5 D3 D4 D6 D8 D10 D10 D11 D11 DC DC DD DD DE DN DB DB DD.2 D11.9 D5.5 ELEV. MACHINE ROOM ST-D2.7 DD.5 DB.42% MIN. 2% MIN. 2% MI N . 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MI N . D700 2% MIN. 2% MI N . 60' - 6 1/8" H.P. 59' - 9" L.P. 59' - 9" L.P. 2% MI N . R 1 7 ' - 4 " 2% MI N . 2% MIN . 1 1/8"=1'-0" BLDG D ROOF PLAN - WEATHERPROOF POWER SUPPLY OUTLET DEDICATED TO POWERED PLATFORM. SEE ELECTRICAL REQUIREMENTS. POWER TO BE LOCATED NO MORE THAN 50' FROM ANY DROP LOCATION TYP. 8M 8M 8M 8M PLATFORMS PROVIDED BY WINDOW WASHING CONTRACTOR AT THE TIME OF CLEANING TO BE GROUND RIGGED & ROOF RIGGED. 6' CLEARANCE REQUIRED AT GROUND LEVEL FOR PLATFORM MANEUVERING PORTABLE OUTRIGGER SEOR TO PROVIDE BLOCKING @ FRONT FULCRUM OF OUTRIGGER TYP PERMANENT ACCESS REQUIRED @ LEVEL 3 LOW ROOF RIGGING 12 ' - 0 " 9' - 6 " 7' - 0 " 7' - 0 " 7' - 0 " ROOF TIE-BACK ANCHOR TO COMPLY WITH SECTION 3291 (f) OF THE CCR FOR UNSCHEDULED FACADE MAINTENANCE TYP PERMANENT ACCESS REQUIRED AT HIGH ROOF, TYP. PER CCR 1670(a) & 3270 (PERMANENT LADDER, STAIR, ROOF HATCH AND 42" PARAPET OR GUARDRAIL) GROUND OPERATIONS ZONE AND ACCESS AREAS REQUIRED (TYP) DRIFTING REQUIRED AT SECOND LEVEL BROW. DRIFTING REQUIRED AT SECOND LEVEL BROW. SWING STAGE LAUNCH ZONE, 6' CLEARANCE REQUIRED AROUND PLATFORM 1M 1M 1M 1M FIRST LEVEL CANOPY, PERMANENT ACCESS REQUIRED PER CCR 1670(a) & 3270 (PERMANENT LADDER, STAIR, ROOF HATCH AND 42" PARAPET OR GUARDRAIL) 14'-71 8" HB HB HB HB HB HBHB SECOND LEVEL ROOF, PERMANENT ACCESS REQUIRED DN FIRST LEVEL CANOPY, PERMANENT ACCESS REQUIRED 7' - 4 " 1M GUARDRAIL REQUIRED PER CCR 1670(a) & 3270 A6 A1 A2 A3 A4 A5 A7 A8 A9 A10 A11 A12 A13 A14 A16 A17 A18 A21 A23 A15 A22 R2 R1 A25 A20 A19 A26 A24 7'-3" TYP. 4'-6" TYP. 4'-6" TYP. 7'-3" TYP. 2 EBM2.3 2 EBM2.2 3 EBM2.2 1 EBM2.3 1 EBM2.1 7" 6" 6"0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com N LEGEND SYM PART DETAIL QTY TIE-BACK ANCHOR 2 / EBM3.0 26 / 26 OUTRIGGER SUPPORT BASE 1 / EBM3.2 2 / 2 12' PORTABLE OUTRIGGER 1 / EBM3.1 2 / 2 10' RETRACTABLE OUTRIGGER BEAM 2 / EBM3.1 1 / 1 FRONT FULCRUM (OUTRIGGER) BLOCKING BY OTHERS 3 / EBM3.1 18 / 18 EBM1.2 HATCH LEGEND WATER FED POLE OPERATIONS ZONE (GROUND LEVEL & LOW ROOF) HIGH/LOW LEVEL ROOF TOP BOOM LIFT OPERATIONS ZONE (GROUND LEVEL) SWING STAGE OPERATIONS ZONE (ROOF TOPS & GROUNDLEVEL) 1 2 08/21/2024 42 " C L R 30 " C L R 42 " C L R 30 " C L R 30 " C L R 30 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 11 12 13 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 2% MI N . DN 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 30 " C L R 42"CLR 30"CLR FRONT DN FRONT 42" CLR 30" CLR 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R 13 A B C C.3 C.4 13.4 D1 D2 D5 D7 D8.1 D8.1 D11.5 D12 D12 DA DA DC.5 DJ DM DP DL DK DH DG DF DE.5 D3 D4 D6 D8 D10 D10 D11 D11 DC DC DD DD DE DN DB DB DD.2 D11.9 D5.5 ELEV. MACHINE ROOM ST-D2.7 DD.5 DB.42% MIN. 2% MIN. 2% MI N . 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MI N . D700 2% MIN. 2% MI N . 60' - 6 1/8" H.P. 59' - 9" L.P. 59' - 9" L.P. 2% MI N . R 1 7 ' - 4 " 2% MI N . 2% MI N . 1 1/8"=1'-0" BLDG D ROOF PLAN - 26'-3" 26'-3" 26'-3" 24'-6" 11'-4" 7'-8"12'-2"8'-11"10'-0"11'-6"12'-0"7'-7"13'-6"12'-0"12'-0"7'-11"6'-3" 12'-8" 4'-2" 4'-21 4" 6'-9" 7'-2" 11'-2" 11'-0" 9'-5"13'-0"8'-9" 2'-11" 9'-0" 4'-6" 2'-2" 6'-3" 10'-0" TYP. 12'-0" 3'-6" 7'-81 4" 11'-31 2" DIMENSIONING 7'-8" TYP. 6'-5"6'-0" 4'-4" 4'-4" 5'-6" 1'-2" 2'-0" 2'-10" 12'-0" A6 2'-9" A1 A2 A3 A4 A5 A7 A8 A9 A10 A11 A12 A13 A14 A16 A17 A18 A21 A23 A15 A22 R2 R1 A25 A20 A19 A26 A24 3'-6" 11'-0" 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com N LEGEND SYM PART DETAIL QTY TIE-BACK ANCHOR 2 / EBM3.0 26 / 26 OUTRIGGER SUPPORT BASE 1 / EBM3.2 2 / 2 EBM1.3 1 2 08/21/2024 LEVEL 1 0" LEVEL 2 9' - 0" BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' BLDG. C UPPER ROOF (T.O.S) EL +48.83' 8910111213 7.58.59.510.511.512.513.413.5 AVERAGE GRADE EL -0.60' BLDG.C PLANNING HEIGHT LIMIT EL +49.73' BLDG. C (E) ROOF H.P. (T.O.C) EL +38.83' BLDG. C ROOFTOP PATIO EL +39.33' 48'-0" MAX. WATER-FED POLE ZONE 48'-0" MAX. WATER-FED POLE ZONE 1 1/8"=1'-0" BLDG C - SOUTH 1 ELEVATION 2 1/8"=1'-0" BLDG C - NORTH 2 ELEVATION FIRST LEVEL ROOF BETWEEN BLDG C & D FIRST LEVEL CANOPY BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' BLDG. C UPPER ROOF (T.O.S) EL +48.83' 8 9 10 11 12 137.5 8.5 9.5 10.5 11.5 12.5 13.4 13.5 AVERAGE GRADE EL -0.60' BLDG.C PLANNING HEIGHT LIMIT EL +49.73' BLDG. C (E) ROOF H.P. (T.O.C) EL +38.83' BLDG. C ROOFTOP PATIO EL +39.33' 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com EBM2.0 HATCH LEGEND WINDOWS TO BE ACCESSED FROM EXTERIOR BY GROUND OPERATIONS OR FROM BALCONY (HIGH-REACH POLE; ASSUMING NO POWER LINES WITHIN RANGE OF MOTION), SEE DETAIL 1 / EBM6.0 WINDOWS TO BE ACCESSED FROM EXTERIOR BY SUSPENDED OPERATIONS (WORK PLATFORM / SINGLE MAN BASKET) SEE DETAIL 1 / EBM3.3 OPERABLE WINDOW TO BE ACCESSED FROM INTERIOR SEE DETAIL 1 & 2 / EBM3.2 DOORS & WINDOWS WITHOUT HATCH SHALL BE CLEANED FROM RESPECTIVE FLOOR / BALCONY 08/21/2024 BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' BLDG. C UPPER ROOF (T.O.S) EL +48.83' ABCDC.3C.4 AVERAGE GRADE EL -0.60' BLDG.C PLANNING HEIGHT LIMIT EL +49.73' BLDG. C (E) ROOF H.P. (T.O.C) EL +38.83' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' BLDG. C UPPER ROOF EL +48.20' 1 0.623456 0.52.53.54.55.56.5 AVERAGE GRADE EL -0.60' 1.5 12 ' - 5 " 12 ' - 1 1 " 50 ' - 4 " MA X A L L O W A B L E H E I G H T P E R ZO N I N G BLDG.C PLANNING HEIGHT LIMIT EL +49.73' BLDG. C (E) ROOF H.P. EL +38.83' 48'-0" MAX. WATER-FED POLE ZONE 48'-0" MAX. WATER-FED POLE ZONE BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' BLDG. C UPPER ROOF EL +48.20' A B C C.3 C.4 D AVERAGE GRADE EL -0.60' 12 ' - 5 " 12 ' - 1 1 " 48 ' - 9 5 / 8 " BLDG.C PLANNING HEIGHT LIMIT EL +49.73' 50 ' - 4 " MA X A L L O W A B L E H E I G H T P E R ZO N I N G BLDG. C (E) ROOF H.P. EL +38.83' 48'-0" MAX. WATER-FED POLE ZONE 48'-0" MAX. WATER-FED POLE ZONE 3 1/8"=1'-0" BLDG C - NORTH 1 ELEVATION 4 1/8"=1'-0" BLDG C - SOUTH 2 ELEVATION 2 1/8"=1'-0" BLDG C - WEST ELEVATION11/8"=1'-0" BLDG C - EAST ELEVATION FIRST LEVEL CANOPY Tectonic Copyright 2007 BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' BLDG. C UPPER ROOF (T.O.S) EL +48.83' 10.6 2 3 4 5 60.5 2.5 3.5 4.5 5.5 6.5 AVERAGE GRADE EL -0.60' 1.5 BLDG.C PLANNING HEIGHT LIMIT EL +49.73' BLDG. C (E) ROOF H.P. (T.O.C) EL +38.83' BLDG. C ROOFTOP PATIO EL +39.33' 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com EBM2.1 HATCH LEGEND WINDOWS TO BE ACCESSED FROM EXTERIOR BY GROUND OPERATIONS OR FROM BALCONY (HIGH-REACH POLE; ASSUMING NO POWER LINES WITHIN RANGE OF MOTION), SEE DETAIL 1 / EBM6.0 WINDOWS TO BE ACCESSED FROM EXTERIOR BY SUSPENDED OPERATIONS (WORK PLATFORM / SINGLE MAN BASKET) SEE DETAIL 1 / EBM3.3 OPERABLE WINDOW TO BE ACCESSED FROM INTERIOR SEE DETAIL 1 & 2 / EBM3.2 DOORS & WINDOWS WITHOUT HATCH SHALL BE CLEANED FROM RESPECTIVE FLOOR / BALCONY 3 08/21/2024 BLDG. C & D LEVEL 1 EL +0.00' BLDG. D LEVEL 2 EL +10.00' BLDG. D LEVEL 3 EL +19.50' BLDG. D LEVEL 4 EL +29.50' BLDG. D LEVEL 5 EL +39.50' BLDG. D LEVEL 6 EL +49.50' AVERAGE GRADE EL -0.60' BLDG. D PLANNING HEIGHT LIMIT EL +63.40' DADJDMDPDLDKDHDGDFDCDDDEDNDBDD.2 BLDG. D ROOF EL +59.50' DL.5 DK.5 DJ.5 DH.5 DG.5 DB.4 2 1/8"=1'-0" BLDG D - EAST ELEVATION 48'-0" MAX. WATER-FED POLE ZONE 1 1/8"=1'-0" BLDG D - WEST ELEVATION 48'-0" MAX. WATER-FED POLE ZONE 48'-0" MAX. WATER-FED POLE ZONE BLDG. C & D LEVEL 1 EL +0.00' BLDG. D LEVEL 2 EL +10.00' BLDG. D LEVEL 3 EL +19.50' BLDG. D LEVEL 4 EL +29.50' BLDG. D LEVEL 5 EL +39.50' BLDG. D LEVEL 6 EL +49.50' AVERAGE GRADE EL -0.60' BLDG. D PLANNING HEIGHT LIMIT EL +63.40' DA DJ DM DPDLDKDHDGDFDCDDDEDNDBDD.2 BLDG. D ROOF EL +59.50' DL.5DK.5DJ.5DH.5DG.5DD.5DB.4 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com EBM2.2 HATCH LEGEND WINDOWS TO BE ACCESSED FROM EXTERIOR BY GROUND OPERATIONS OR FROM BALCONY (HIGH-REACH POLE; ASSUMING NO POWER LINES WITHIN RANGE OF MOTION), SEE DETAIL 1 / EBM6.0 WINDOWS TO BE ACCESSED FROM EXTERIOR BY SUSPENDED OPERATIONS (WORK PLATFORM / SINGLE MAN BASKET) SEE DETAIL 1 / EBM3.3 OPERABLE WINDOW TO BE ACCESSED FROM INTERIOR SEE DETAIL 1 & 2 / EBM3.2 DOORS & WINDOWS WITHOUT HATCH SHALL BE CLEANED FROM RESPECTIVE FLOOR / BALCONY 3 08/21/2024 2 1/8"=1'-0" BLDG D - SOUTH ELEVATION 48'-0" MAX. WATER-FED POLE ZONE 1 1/8"=1'-0" BLDG D - NORTH ELEVATION 48'-0" MAX. WATER-FED POLE ZONE 48'-0" MAX. WATER-FED POLE ZONE BLDG. C & D LEVEL 1 EL +0.00' BLDG. D LEVEL 2 EL +10.00' BLDG. D LEVEL 3 EL +19.50' BLDG. D LEVEL 4 EL +29.50' BLDG. D LEVEL 5 EL +39.50' BLDG. D LEVEL 6 EL +49.50' AVERAGE GRADE EL -0.60' BLDG. D PLANNING HEIGHT LIMIT EL +63.40' D1D2D5D7D8.1D12 D3D4D6D8D10D11D11.9 BLDG. D ROOF EL +59.50' D5.5 BLDG. C & D LEVEL 1 EL +0.00' BLDG. D LEVEL 2 EL +10.00' BLDG. D LEVEL 3 EL +19.50' BLDG. D LEVEL 4 EL +29.50' BLDG. D LEVEL 5 EL +39.50' BLDG. D LEVEL 6 EL +49.50' AVERAGE GRADE EL -0.60' BLDG. D PLANNING HEIGHT LIMIT EL +63.40' D1 D2 D3.1 D5 D7 D8.1 D12D3D4D6D8D10D11D11.9 BLDG. D ROOF EL +59.50' D5.5 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com EBM2.3 HATCH LEGEND WINDOWS TO BE ACCESSED FROM EXTERIOR BY GROUND OPERATIONS OR FROM BALCONY (HIGH-REACH POLE; ASSUMING NO POWER LINES WITHIN RANGE OF MOTION), SEE DETAIL 1 / EBM6.0 WINDOWS TO BE ACCESSED FROM EXTERIOR BY SUSPENDED OPERATIONS (WORK PLATFORM / SINGLE MAN BASKET) SEE DETAIL 1 / EBM3.3 OPERABLE WINDOW TO BE ACCESSED FROM INTERIOR SEE DETAIL 1 & 2 / EBM3.2 DOORS & WINDOWS WITHOUT HATCH SHALL BE CLEANED FROM RESPECTIVE FLOOR / BALCONY 3 08/21/2024 PL WASHERS 3" 3" Ø13 16" 3 8" THK. 1'-8" HSS 4.5x.237 A500 GR. B SIDE 5/16 1/2" GR 50 CAP PLATE PAD EYE SEE DETAIL 4 / - 3/8 1/4 5000# ULT. ANY DIRECTION (OSHA) 2" 1'-2" VIF A307 THREADED ROD ASSY 3 4" 2 1-1/2"=1'-0" TIE-BACK ANCHOR FABRICATION DETAIL Ø13 16" 5/8" THK. PLAN VIEW 1'-0" VIF 9" VIF 9" VIF 1'-0" VIF NOTES: 1. ENTIRE ANCHOR ASSEMBLY TO BE HOT DIPPED GALVANIZED. 2.ARCH TO VERIFY ADEQUATE ANCHOR HEIGHT FOR WATERPROOFING 3.WATER PROOFING BY OTHERS 11 2" TYP DETAIL 1 / - FOR ATTACHMENT DETAIL 11 2" TYP Ø2" R 1 16" R1 4" ISOMETRIC SECTION TOP VIEWFRONT VIEW 4 3"=1'-0" PAD-EYE DETAIL 17 8" 17 8" 33 4" 7 8" 2" 33 4" 1" 1" 1018 COLD ROLLED STEEL 33 4" PLAN VIEW 1'-0" VIF 9" VIF PER PLAN (24" O.C. UNO AT ROOF) JOIST PER SEOR, TYP. STRAPPING PER SEOR, TYP. BLOCKING PER SEOR, TYP. 1'-10" MAX (4) 3/4" DIA THRU-BOLTS TO BLKG BELOW STRAPPING PER SEOR JOIST PER SEOR, TYP.BLOCKING PER SEOR, TYP. SHEATHING PER SEOR 1 1-1/2"=1'-0" TIE-BACK ANCHOR ATTACHMENT DETAIL SIDE VIEW TIE-BACK ANCHOR SEE DETAIL 2 / - ADJ PARAPET INSTALL ANCHOR W/ PAD EYE IN PLANE TO DROP LOCATION NOTES: 1. ALL ANCHORS ARE DESIGNED FOR 5000# IN ANY DIRECTION, THIS IS AN AESTHETIC DECISION 3 1-1/2"=1'-0" ANCHOR INSTALL ORIENTATION 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com EBM3.0 ANCHOR MATERIALS ITEM DETAIL QUANTITY TIE-BACK ANCHOR 2 / -26 3/4" HDG THREADED ROD ASSY: (2) NUTS, (1) SPLITWASHER, (2) FLAT WASHERS, & (1) PL WASHER 1 / -104 TIE-BACK ANCHOR NOTES: 1.APPLICABLE STANDARD MET INCLUDE OSHA 1926.502, ANSI Z359.1, & CAL-OSHA CHAPTER 4, ARTICLE 5, SECTION 3291 (f), SECTION 3282, AND SECTION 3296. 2.ANCHORS MAY BE USED FOR FALL PROTECTION AS WELL AS SUSPENDED MAINTENANCE OPERATIONS IF SPECIFIED IN OPOS. 3.ANCHOR SHALL BE VISUALLY INSPECTED BY A COMPETENT PERSON PRIOR TO EACH USE. DO NOT USE IF THERE IS ANY QUESTION ABOUT THE ABILITY OF THE ANCHOR TO SAFELY SUPPORT THE REQUIRED LOADS. 4.EACH SAFETY LINE SHALL BE ATTACHED TO A SEPARATE ROOF ANCHOR. DO NOT ATTACH MORE THAN ONE (1) LINE TO AN ANCHOR AT A TIME. DESIGN CAPACITY AND TESTING LOADS & PROCEDURES: 1.WORKING LOAD = 1,250 LBS. W/ A FACTOR OF SAFETY (F.S.) =4.0 2.PROOF LOAD = 2,500 LBS. HELD FOR 5 MINUTES AND RETURNED TO 0 LBS WITH LESS THAN A DEGREE OF PERMANENT DEFORMATION CCR Title 8, 4.7.1.6 §3296 (b)(4)(B). 3.ULTIMATE LOAD = 5,000 LBS. ANCHOR IS DESIGNED TO SUSTAIN A 5,000 LBS. LOAD APPLIED IN ANY DIRECTION WITHOUT PERMANENT DEFORMATION CCR Title 8, 4.7.1.1 §3291 (f)(2)(C). ENGINEERING NOTE: 1.PER CBC CHAPTER 16, 1607.10.4 FALL ARREST AND LIFELINE ANCHORAGES - IN ADDITION TO ANY OTHER APPLICABLE LIVE LOADS, FALL ARREST AND LIFELINE ANCHORAGES AND STRUCTURAL ELEMENTS THAT SUPPORT THESE ANCHORAGES SHALL BE DESIGNED FOR A LIVE LOAD OF NOT LESS THAN 3,100 POUNDS (13.8 KN) FOR EACH ATTACHED LIFELINE, IN EVERY DIRECTION THAT A FALL ARREST LOAD CAN BE APPLIED. 2.PER CBC CHAPTER 16, 1605.2 LOAD COMBINATIONS - FALL ARREST AND FACADE ACCESS LOADS ARE DESIGNED AS LIVE LOADS, THE APPLICABLE LOAD COMBINATION IS: 1.6L = 1.6 x 3100# = 5000# ULTIMATE 3.VERIFICATION OF THE CAPACITY OF STRUCTURE, STRAPPING, BLOCKING, OR FRAMING TO SUPPORT REQUIRED LOADS IMPOSED BY THE ANCHOR DEPICTED SHALL BE PERFORMED BY PARENT BUILDING STRUCTURAL ENGINEER. DETAIL ORIGIN: SSK-TIE-BACK DETAIL REFER TO STRUCTURAL FOR ADDITIONAL INFO 08/21/2024 2 3 4 ITEM NO. 620106 920361 920242 920237 H-BEAM 5x5 FRONT/BACK 12FT ADJUSTABLE CASTER DOLLY, 5x5 REAR RIGGING PLATE, 5x5 ADJ. BEAM END STOP 5'-10" 4'-6" MAX (2) RIGGING PLATE, 5x5 12FT 5x5 BEAM, F/R BEAM END STOP PRIMARY SUSPENSION LINE CAPACITY 1,000 LB LOAD SECONDARY LINE SUSPENSION SEE DRAWING L1005-292 FOR PROPER TENSIONING PROCEDURE. MAXIMUM (2) ADJUSTABLE CASTER DOLLY, 5x5 F/R EXISTING ANCHOR 6'-9" MIN (10'-0" REF.) 4'0" MAX MAXIMUM ULTIMATE FULCRUM LOAD = 6,700 LB 3,350 LB PER LEG) WARNING:-Failure to properly install and use this product may result in death or serious injury. Follow the manufacturer’s instruction manual. Suspended Scaffold Systems must be installed and dismantled by, or under the supervision of, a trained and competent person. -Bee Access declines any responsibility for any special layouts, rigging or structural combinations beyond the descriptions of this drawing, or components manufactured by others. Any installation of this equipment other than in strict accordance with this drawing shall be at the Operator’s risk. -Designed to be used with Bee Access components only. -Never let the equipment be moved or operated by unauthorized personnel. -Never load this equipment above its rated load capacity. -Do not alter any products and never use it for purposes or in ways for which it was not intended. -Inspect all equipment before each use. Never use damaged equipment. -Read and comply with the “Code of Safe Practices for Suspended Powered Scaffolds” issued by the Scaffold & Access Industry Association (available from your supplier). MAXIMUM COUNTERWEIGHT LOADING OF 2,700 LB APPLIED TO STRUCTURE OUTRIGGER FORCES APPLIED TO STRUCTURE Fx Fy Fz Mx My Mz FRONT FIXED FULCRUM N/A 6700 LBS (DOWN)N/A N/A N/A N/A TIE-BACK ANCHOR N/A 2700 LBS (UP)N/A N/A N/A N/A +Fy +Mz +Fz +My +Mx +Fx EBM SUPPORT NOTES: LOADS ARE BASED ON 2.5X WORKING LOAD PER CBC 1607.10.3 12' PORTABLE BACKFED OUTRIGGER DETAIL 3/4" = 1'-0" NOTES: 1. SUPPORT STAND WILL BE IN FRONT OR BEHIND RIGGING POINT DEPENDING ON OUTRIGGER CONFIGURATION 1 1 2 2 1 1 QTY.PART NO.DESCRIPTION DICAPAD D1818 1-1/2" = 1'-0"3 1'-6" 1'-6" 1" HIGH DENSITY THERMOPLASTIC PLAN NOTES: 1. PADS TO BE PLACED UNDER FRONT FULCRUM OF PORTABLE OUTRIGGER TO PREVENT DAMAGE TO ROOF HANDLE RETRACTABLE BACKFED ALUMINUM OUTRIGGER BEAM SEE DETAIL 5 / EBM3.2 OUTRIGGER SUPPORT POST SEE DETAIL 2 / EBM3.2 SUSPENSION LINE AND FALL ARREST LINE ATTACH TO POWERED PLATFORM BY OTHERS 10° MAX ANGLE FOR DRIFTING 5'-4" PER ELEV. 3'-11" 2700 LBS MAX (ULTIMATE) VERTICAL UPWARD LOAD 6700 LBS MAX (ULTIMATE) VERTICAL DOWNWARD LOAD 6" MIN 1000 LBS MAX. WORKING LOAD 4000 LBS FACTORED LOAD NOTES: 1. OUTRIGGER SHOWN AS "IN USE" CONFIGURATION. MUST BE DISMANTLED WHEN NOT IN USE 1'-10" OUTRIGGER BASE PER DETAIL 1 / EBM3.2 OUTRIGGER BASE ATTACHMENT PER DETAIL 1 / EBM3.2 10'-0" 5'-6" (SUPPORT LENGTH) 1.5 X CANTILEVER MIN 3'-6" (CANTILEVER)1'-0" TYP 2 1"=1'-0" 10FT SEMI-PORTABLE OUTRIGGER DETAIL OUTRIGGER FORCES APPLIED TO STRUCTURE Fx Fy Fz Mx My Mz FRONT STAND 0.8 K 6700 LBS (DOWN)0.8 K 5.0 K-FT 1.0 K-FT 1.1 K-FT REAR STAND 0.8 K 2700 LBS (UP)0.8 K 0.2 K-FT 2.0 K-FT 0 K-FT +Fy +Mz +Fz +My +Mx +Fx EBM SUPPORT STRUCTURE BELOW NOTES: 1. LOADS ARE BASED ON 4.0X WORKING LOAD DOGLINE TYPICAL 208V 20A MOTOR MODULAR POWERED PLATFORM BY MAINTENANCE CONTRACTOR 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com EBM3.1 POWERED PLATFORM INSTALLATION NOTES: PER CCR TITLE 8, DIV. 1, CHAP. 4.7.1.6. §3294. (K) ELECTRICAL REQUIREMENTS. THE FOLLOWING ELECTRICAL REQUIREMENTS APPLY TO BUILDINGS WHICH UTILIZE WORKING PLATFORMS FOR BUILDING MAINTENANCE: (1)GENERAL BUILDING ELECTRICAL INSTALLATIONS SHALL COMPLY WITH THE ELECTRICAL SAFETY ORDERS, UNLESS OTHERWISE SPECIFIED IN THIS ARTICLE; (2)BUILDING ELECTRICAL WIRING SHALL BE OF SUCH CAPACITY THAT WHEN FULL LOAD IS APPLIED TO THE EQUIPMENT POWER CIRCUIT, NOT MORE THAN A FIVE PERCENT DROP FROM BUILDING SERVICE-VAULT VOLTAGE SHALL OCCUR AT ANY POWER CIRCUIT OUTLET USED BY EQUIPMENT REGULATED BY THIS ARTICLE; (3) THE EQUIPMENT POWER CIRCUIT SHALL BE AN INDEPENDENT ELECTRICAL CIRCUIT THAT SHALL REMAIN SEPARATE FROM ALL OTHER EQUIPMENT WITHIN OR ON THE BUILDING, OTHER THAN POWER CIRCUITS USED FOR HAND TOOLS THAT WILL BE USED IN CONJUNCTION WITH THE EQUIPMENT. IF THE BUILDING IS PROVIDED WITH AN EMERGENCY POWER SYSTEM, THE EQUIPMENT POWER CIRCUIT MAY ALSO BE CONNECTED TO THIS SYSTEM; (4)THE POWER CIRCUIT SHALL BE PROVIDED WITH A DISCONNECT SWITCH THAT CAN BE LOCKED IN THE “OFF” AND “ON” POSITIONS. THE SWITCH SHALL BE CONVENIENTLY LOCATED WITH RESPECT TO THE PRIMARY OPERATING AREA OF THE EQUIPMENT TO ALLOW THE OPERATORS OF THE EQUIPMENT ACCESS TO THE SWITCH; (5)THE DISCONNECT SWITCH FOR THE POWER CIRCUIT SHALL BE LOCKED IN THE “ON” POSITION WHEN THE EQUIPMENT IS IN USE; AND (6)AN EFFECTIVE TWO-WAY VOICE COMMUNICATION SYSTEM SHALL BE PROVIDED BETWEEN THE EQUIPMENT OPERATORS AND PERSONS STATIONED WITHIN THE BUILDING BEING SERVICED. THE COMMUNICATIONS FACILITY SHALL BE OPERABLE AND SHALL BE MANNED AT ALL TIMES BY PERSONS STATIONED WITHIN THE BUILDING WHENEVER THE PLATFORM IS BEING USED. (TITLE 24, PART 2, 2-8521) ELECTRICAL REQUIREMENTS: 1.ELECTRICAL WEATHERPROOF RECEPTACLE: NEMA L6 - 30R TWIST-LOCK, 30A; 208V; 1PH; 60HZ. 2.PROVIDE 1/2" DIA. STAINLESS STEEL EYEBOLT FOR STRAIN RELIEF ANCHOR, INSTALL WITHIN 12" MAX OF EACH OUTLET. 3.ANCHOR TO BE CAPABLE OF WITHSTANDING 100 LBS. PULL IN ANY DIRECTION WITHIN 18" OF RECEPTACLE. OUTRIGGER NOTES: PER CCR TITLE 8, 4.7.1.6 §3291 (D) OUTRIGGER BEAMS: (1)OUTRIGGER BEAMS SHALL NOT BE EMPLOYED ON BUILDINGS EXCEEDING 130 FEET IN HEIGHT UNLESS ACCEPTABLE TO THE DIVISION. ALL OUTRIGGER BEAMS SHALL BE DESIGNED TO SUPPORT THE RATED LOAD IMPARTED BY THE SUSPENDED SCAFFOLD OR BOATSWAIN'S CHAIR WITH A SAFETY FACTOR OF AT LEAST 4. OUTRIGGER BEAMS SHALL NOT EXTEND MORE THAN 6 FEET BEYOND THE FACE OF THE BUILDING. ONLY STEEL OR HIGH STRENGTH ALLOY BEAMS SHALL BE USED. THE INBOARD END OF OUTRIGGER BEAMS, MEASURED FROM THE FULCRUM POINT TO THE ANCHORAGE POINT, SHALL BE NOT LESS THAN 1 1/2 TIMES THE OUTBOARD END IN LENGTH. THE FULCRUM POINT OF THE BEAM SHALL REST ON LEG(S) OR EQUIVALENT SUPPORTS SECURELY ATTACHED TO THE BEAM AND SO ARRANGED AS TO PREVENT LATERAL OVERTURNING OF THE BEAM. BEARING PADS SHALL BE SECURELY AFFIXED TO EACH SUPPORT AND SHALL BE OF SUFFICIENT AREA TO SAFELY DISTRIBUTE IMPOSED LOADS TO THE ROOF STRUCTURE. THE INBOARD ENDS OF OUTRIGGER BEAMS SHALL BE SECURELY ANCHORED BY MEANS OF TENSION MEMBERS (TIE-DOWN) AFFIXED TO THE STRUCTURAL FRAME OF THE ROOF IN SUCH A MANNER THAT APPLIED FORCES ARE RESISTED WITHIN ALLOWABLE LIMITS AFFORDING A SAFETY FACTOR OF AT LEAST 4. ALL TIE-DOWN FITTINGS AT THE INBOARD END OF THE BEAM SHALL BE OF A TYPE THAT VIBRATION EFFECTS SHALL NOT PRODUCE ACCIDENTAL DISENGAGEMENT. SAFETY HOOKS FOR BEAM TIE-DOWN PURPOSES SHALL NOT BE USED. THE USE OF COUNTERWEIGHTS AT THE INBOARD END OF MOBILE AND FIXED OUTRIGGER BEAMS ARE PROHIBITED. (2)(E)PORTABLE OUTRIGGERS) THE OUTRIGGER SHALL BE SECURED WITH A TIE-BACK TO A VERIFIED ANCHORAGE ON THE BUILDING DURING THE ENTIRE TIME OF USE. THE ANCHORAGE SHALL BE DESIGNED TO HAVE A SAFETY FACTOR OF NOT LESS THAN FOUR BASED ON THE RATED CAPACITY OF THE OUTRIGGER. (G)EACH OUTRIGGER SHALL BE DESIGNED BY A REGISTERED ENGINEER TO SUPPORT A LOAD OF 4 TIMES THE RATED HOIST CAPACITY OR THE TOTAL LOAD WHICHEVER IS GREATER. OUTRIGGER BEAMS SHALL HAVE A MINIMUM RATED CAPACITY OF 1000 POUNDS. (H)THE OUTRIGGER BEAM SHALL BE SECURED AGAINST HORIZONTAL MOVEMENT WHEN IN USE. (I)PORTABLE OUTRIGGERS WEIGHING MORE THAN 80 POUNDS SHALL BE PROVIDED WITH A STABLE MEANS FOR ITS TRANSPORT (WHEELS OR CART). (J)EACH OUTRIGGER SHALL BE SO LOCATED THAT THE SUSPENSION WIRE ROPES, FOR TWO POINT SUSPENDED WORKING PLATFORMS, ARE HUNG PARALLEL. (K) THE PARTS OF SECTIONAL OUTRIGGER BEAM(S) (I.E. AN OUTRIGGER BEAM(S) CONSISTING OF MORE THAN ONE PIECE) SHALL BE IDENTIFIED (E.G. NUMBERED, COLOR-CODED). PARTS SHALL NOT BE INTERCHANGED OR SUBSTITUTED EXCEPT WITH THE APPROVAL OF THE MANUFACTURER. (3)EACH OUTRIGGER BEAM SHALL BE PROVIDED WITH A SECURELY AFFIXED, DURABLE AND READILY VISIBLE METAL PLATE BEARING THE FOLLOWING INFORMATION IN LETTERS AT LEAST 1/4-INCH IN HEIGHT. (A) THE BEAM'S RATED LOAD. (B)MANUFACTURER'S NAME. (C)PRECAUTIONARY WARNING MESSAGE PROHIBITING USE OF THE BEAM WITHIN 10 FEET OF HIGH-VOLTAGE LINES. (TITLE 24, PART 2, SECTION 3105A.4.2.) TESTING LOADS & PROCEDURES: 1.PROOF LOAD = 2000 LBS. LOAD SUSPENSION DEVICES SHALL NOT BE TESTED TO MORE THAN 2 TIMES THE RATED WORKING LOAD WHICH THE DEVICE IS DESIGNED TO LIFT AND/OR SUPPORT. CCR TITLE 8, 4.7.1.6 §3296 (B)(4)(A). 1.1.THE PROOF LOAD ITEM WILL BE TESTED TO TWICE THE RESULTANT FORCE OF THE WORKING LOAD. THEREFORE THE INDIVIDUAL OUTRIGGER STANDS SHALL BE TESTED TO A LOAD OF 2000 LBS PER A LICENSED ENGINEER'S PROCEDURE HELD FOR 5 MINUTES AND RETURNED TO 0 LBS WITH LESS THAN A DEGREE OF PERMANENT DEFORMATION ENGINEERING NOTES: 1.PER CBC CHAPTER 1607.11.3 ELEMENTS SUPPORTING HOISTS FOR FACADE ACCESS AND BUILDING MAINTENANCE EQUIPMENT - IN ADDITION TO ANY OTHER APPLICABLE LIVE LOADS, STRUCTURAL ELEMENTS THAT SUPPORT HOISTS FOR FACADE ACCESS AND BUILDING MAINTENANCE EQUIPMENT SHALL BE DESIGNED FOR A LIVE LOAD OF 2.5 TIMES THE RATED LOAD OF THE HOIST OR THE STALL LOAD OF THE HOISTS, WHICHEVER IS LARGER. 2.PER ASCE 7, SECTION 2.3 LOAD COMBINATIONS FOR STRENGTH DESIGN - FALL ARREST AND FACADE ACCESS LOADS ARE DESIGNED AS LIVE LOADS, THE APPLICABLE LOAD COMBINATION IS: 1.6L = 1.6 x 2.5 x 1000# = 4000# ULTIMATE 3.VERIFICATION OF THE CAPACITY OF STRUCTURE, STRAPPING, BLOCKING, OR FRAMING TO SUPPORT REQUIRED LOADS IMPOSED BY THE ANCHOR DEPICTED SHALL BE PERFORMED BY PARENT BUILDING STRUCTURAL ENGINEER. PORTABLE OUTRIGGER MATERIALS ITEM DETAIL QTY 12 FT PORTABLE OUTRIGGER ASSY 1 / -2 10 FT SEMI-PORTABLE OUTRIGGER 2 / -1 D1818 DICAPADS 3 / -4 08/21/2024 1/4 3/8 OUTRIGGER SUPPORT SOCKET SEE DETAIL 3 / - 1'-10" 4" SCH 80 PIPE (4.5" O.D.) SIDE PLAN NOTE: FOR ATTACHMENT SEE DETAIL 2 / EBM3.1 1 1-1/2"=1'-0" OUTRIGGER SUPPORT BASE PL WASHERS 3" 3" Ø13 16" 3 8" THK. 1'-2" VIF A307 THREADED ROD ASSY 3 4" Ø13 16" 5/8" THK. 1'-0" VIF 9" VIF 9" VIF 1'-0" VIF 11 2" TYP 11 2" TYP 5/16 3'-11" (2) Ø1 1 16" HOLES FOR 1" SS PINS 4x4x1/4" SQ TUBE A500 GR B 3'-11" FRONT SIDE 1/4 NOTES: 1. MATERIAL: HOT-DIPPED GALVANIZED STEEL 2. WEIGHT: 42 LBS 3" 1/4 7"61 2" 5" 41 2" (2) 1" PINS RIVETED TO HEAD WITH 18" LANYARD 5" 7x5x1/4" HSS 45 8" 21 2" Ø1 1 16" FOR 1" SS PINS ONLY ON REAR STAND 7" 2 1-1/2"=1'-0" OUTRIGGER SUPPORT LONG POST 41 2" 2" 2" 2"2" 1'-0" 61 2" 1"5'-6" (CANTILEVER 1.5X MIN.)3'-6" OUTRIGGER SUPPORT HEAD TYP RIGGING ROPES FOR REFERENCE 4" SCH 40 SS (PIPE) BEARING EDGE TO MINIMIZE CABLE WEAR 6x2x3/8" 6061 BEAM STOP PL (2) 1" SS 303 PINS RIVETED TO BEAM WITH 18" LANYARD NOTES: 1. MATERIAL: 6061 T6 ALUMINUM 2. TOTAL WEIGHT: 58 LBS MILL NOTCH FOR PIN ACCESS 1/4 1/4 10'-0" LONG 6x4x1/4" REC. TUBE 6061-T6 1-1/16" HOLE TYP 5 1-1/2"=1'-0" 10' PORTABLE OUTRIGGER BEAM SIDE 51 2" 6" 3" 51 2" R1" Ø1 2" DRAIN HOLE 5X5X3/8" HSS A500 GRB 5X5X3/8" HSS A500 GRB 1 4" 1/2" GR 50 PL PLAN (4) Ø1 1 16" PIN HOLE (ALL SIDES) 3 3"=1'-0" OUTRIGGER SUPPORT SOCKET 8"6" 3 8" 30° CHAMFER 1/4" THRU-HOLE FOR LANYARD 1/4" THRU-HOLE FOR PIN 18" SS CABLE LANYARD RIVETED TO CORRESPONDING PIECE NOTES: 1. MATERIAL: 303 SS A582. 1" PIN 4 3"=1'-0" SS PIN 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com EBM3.2 DETAIL ORIGIN: SSK-TIE-BACK DETAIL REFER TO STRUCTURAL FOR ADDITIONAL INFO SEMI-PORTABLE OUTRIGGER MATERIALS ITEM DETAIL QUANTITY OUTRIGGER SUPPORT BASE 1 / -2 OUTRIGGER SUPPORT POST 2 / -2 10FT OUTRIGGER BEAM (6x4x1/4")5 / -1 3/4" HDG THREADED ROD ASSY: (2) NUTS, (1) SPLITWASHER, (2) FLAT WASHERS, & (1) PL WASHER 1 / -8 SS PIN 6 / -6 08/21/2024 TOP OF WINDOW AT LEVEL 1 TOP OF WINDOW AT LEVEL 2 TOP OF WINDOW AT LEVEL 3 TOP OF WINDOW AT LEVEL 4 TOP OF WINDOW AT LEVEL 5 TOP OF SLAB H ( 4 8 ' M A X . ) h H X 0.25 12'-0" h x 0.25 4'-6" CONCRETE PAVER REQUIRED WHERE PLANTER OCCURS TELESCOPING WATER-FED EXTENSION POLE CONNECTED DE-IONIZED WATER SOURCE SPRAYER AND AGITATOR BRUSH NOTE: 1. DO NOT EXCEED 48' MAXIMUM HEIGHT 2. DO NOT USE WITHIN 10' OF POWER LINES. 1 3/8"=1'-0" GROUND OPERATIONS FOR WINDOW CLEANING REQUIREMENTS WITH WATERFED EXTENSION POLE OPERABLE, CASEMENT OUTWARD SWINGING W/ WASHABILITY HARDWARE FIXED PANE T.O. FINISHED FLOOR 42" MIN VIEW FROM EXTERIOR INTERIOR OUTWARD SWINGING CASEMENT WINDOW PLAN VIEW FIXED PANE 42" MIN VIEW FROM EXTERIOR OUTWARD SWINGING CASEMENT WINDOW PLAN VIEW OPERABLE, CASEMENT OUTWARD SWINGING W/ WASHABILITY HARDWARE. OPERABLE, CASEMENT OUTWARD SWINGING W/ WASHABILITY HARDWARE FIXED PANE VIEW FROM EXTERIOR T.O. FINISHED FLOOR 42" MIN INTERIOR OUTWARD SWINGING CASEMENT WINDOW PLAN VIEW NOTE: 1.INWARD SWINGING CASEMENT WINDOWS ARE ALSO ACCEPTABLE AS OPERABLE, MAINTAIN 42" SILL HEIGHT. 2.SLIDING WINDOW MAY ALSO BE OPERABLE AS LONG AS THE SLIDING PANE CAN BE REMOVED FOR CLEANING BOTH SIDES, MAINTAIN 42" SILL HEIGHT. 3.IF ANY OPENING IS GREATER THAN 18", THEN A TIE-BACK ANCHOR IS REQUIRED IN THE INTERIOR SERVICEABLE AREA. WASH-ABILITY (OFFSET) HINGE REQUIRED TYP 18" MAX TYP (IF SILL <42" AFF) IF OPERABLE WINDOWS HAVE A SILL HEIGHT LESS THAN 42 INCHES AFF, AN 18" LIMITER BAR IS REQUIRED 30" MAX FIXED WINDOW PANE BELOW OPERABLE WINDOW THRESHOLD 18" MAX TYP (IF SILL <42" AFF)18" MAX (IF SILL <42" AFF) 5' MAX WIDTH FOR FIXED WINDOW PANE BETWEEN OPERABLE WINDOWS WASH-ABILITY (OFFSET) HINGE REQUIRED TYP WASH-ABILITY (OFFSET) HINGE REQUIRED TYP 30" MAX WIDTH FOR FIXED WINDOW PANE ADJACENT TO OPERABLE WINDOW INTERIOR 2 3/4"=1'-0" OPERABLE WINDOW REQUIREMENTS SETBACK GUARDRAIL CONDITION WIDE CURB / PARAPET CONDITION A B EXTENDED SLAB EDGE WITH CURB CONDITION C AT LEAST ONE (1) OF THESE CONDITIONS MUST BE SATISFIED AT ALL GUARDRAIL LOCATIONS. 42 " M I N - 4 5 " M A X G U A R D R A I L O R 42 " M I N - 7 2 " M A X . P A R A P E T T.O.FINISHED ROOF T.O.EXTERIOR SIDE OF PARAPET ROOF CURB / LOW PARAPET GUARDRAIL 18" MAX. 6" MAX.INTERIOR SIDE OF PARAPET (ROOF) GUARDRAIL WIDE CURB / PARAPET T.O.EXTERIOR SIDE OF PARAPET T.O.FINISHED ROOF PARAPET WIDTH > 18" 18" MAX. T.O.EXTERIOR SIDE OF PARAPET ROOF CURB / LOW PARAPET GUARDRAIL 42 " M I N - 4 5 " M A X G U A R D R A I L O R 42 " M I N - 7 2 " M A X . P A R A P E T INTERIOR SIDE OF PARAPET (ROOF) 42 " M I N - 4 5 " M A X G U A R D R A I L O R 42 " M I N - 7 2 " M A X . P A R A P E T 18" MAX. 6" MAX. EXTENDED SLAB T.O.FINISHED ROOF 3 1"=1'-0" GUARDRAIL LOCATION REQUIREMENTS 0 PRELIMINARY (BID SET)06/01/23 1 REVISION 1 10/04/23 (BULLETIN 1 - IFC SET) 2 REVISION 2 06/24/24 3 PLAN CHECK 08/15/24 PROJECT HI L T O N A R C A D I A 12 3 W H U N T I N G T O N D R . A R C A D I A , C A 9 1 0 0 7 EX T E R I O R B U I L D I N G M A I N T E N A N C E ( E B M ) 55662 THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF VERSATILE SYSTEMS. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION, OR DISCLOSURE OF THE DRAWING, DOCUMENTS, AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF VERSATILE SYSTEMS. DRAFTED BY: B.Y EBM0.1 GENERAL INFORMATION EBM1.0 SITE/ROOF PLAN - OVERALL EBM1.1 ROOF PLAN - BUILDING C EBM1.2 ROOF PLAN - BUILDING D EBM1.3 ROOF PLAN - BUILDING D DIMS EBM2.0 ELEVATIONS EBM2.1 ELEVATIONS EBM2.2 ELEVATIONS EBM2.3 ELEVATIONS EBM3.0 DETAILS EBM3.1 DETAILS EBM3.2 DETAILS EBM3.3 DETAILS 28258 Ave Stanford, Santa Clarita, CA 91355 818.565.5551 | VerFallPro.com EBM3.3 08/21/2024 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com HILTON ARCADIA HOTEL EBM CALCULATIONS 8/28/24 HILTON ARCADIA HOTEL MHP DRAWINGS FOR EMB SYSTEM A DA DG DH DJ DK DL DM DP D1 D2 D5 D7 D8.1 D12 D8.1 D12 D5.5 DF DG DH DJ DK DL DM DP DF DA DC DC D3 D4 D6 D8 D10 D11 DBDB DD DD.2 DNDN DE D10 D11 D11.9 DD D3.1 DE.5 DE.5 DF.5 DF.5 D11.5 D11.5D7 DD.5DD.5 DC.5DC.5 DB.4 DN UP FRONT 42" CLR 30" CLR 42 " C L R 30" C L R FR O N T 42 " C L R 30 " C L R FR O N T FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R DN A DA DG DH DJ DK DL DM DP D1 D2 D5 D7 D8.1 D12 D8.1 D12 D5.5 DF DG DH DJ DK DL DM DP DF DA DC DC D3 D4 D6 D8 D10 D11 DBDB DD DD.2 DNDN DE D10 D11 D11.9 DD D3.1 DE.5 DE.5 DF.5 DF.5 D11.5 D11.5D7 DD.5DD.5 DC.5DC.5 DB.4 HP 2-1 MAX OP WT=657#RJ4 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 SHTG PER NOTE #3 & 7 S6.1 ,TYP B S3.1 MF2 12 S6.3TYP 12 S6.3TYP 12 S6.4 5 S6.4 TYP 9 S6.4 TYP 8 S6.4 TYP 5 S6.4 DBLDBLDBL B1 FJ 4 ROOF SHTG PER ROOF FRMG PLAN NOTE #4 DBL DBL DBL 6 S6.3 TYP 3 S6.3TYP12 S6.3TYP H S5.3 STAIR 2 CMST12 CMST12 STRAP B1 CMST12 STRAP x 20'-0" RJ4 FJ4 FJ4 DB L FJ 1 FJ 1 FJ 1 B7 B7 FJ4 B7 DBL FJ 4 A5 31' A5 17.5' A5 29.5' A5 18' A5 18' A5 17.5' A5 17.5' A5 17.5' A5 9.5' A5 17.5' A5 17.5' A5 29.5' A5 8' A5 29.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' A6 5.5' A6 5.5' A6 5.5' A5 9' A5 29.5' A6 5.5' A6 5.5' A6 5.5' A5 17.5' A5 17.5' A5 9' FLOOR OPNG PER 12 S6.1 & 13 S6.1 AS APPLICABLE, TYP B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 8x 8 RJ4 RJ4RJ4RJ4 RJ4 A5 17.5' A5 9' A5 17.5' A5 9' B1 B1 B1 B1 B1 SB1 B1B1 B1 A6 5.5' FJ4 SB1 DBL B1 B1 A5 28' FJ 1 FJ 1 SB 3 SB3 SB3 FJ 1 FJ4 B6 5.5' FJ4 FJ 1 SB1 FJ 1 FJ 1 FJ1 A5 17.5' A5 9' A5 9' A5 17.5' A5 27.5' A5 15' A5 16.5'A5 16' A5 5.5' A5 5.5' B6 5.5' B6 5.5' J S5.3 STAIR 2 D S5.4 STAIR 5 A5 30.5' B1 FJ 1 SB 3 B1 HP 1-1 MAX OP WT=657# HP 113C MAX OP WT=393#HP 113B MAX OP WT=519# HP 113B MAX OP WT=519# HP 4-2 MAX OP WT=810# HP 3-2 MAX OP WT=810# DOAS 1 MAX OP WT=2,622# +400# CURB DB L 7" x 9 1 / 2 " L V L 7"x9 1/2" LVL 7" x 9 1 / 2 " L V L 7"x9 1/2" LVL DB L SB 4 DBL A5 18' 6x10 HDR, TYP UNO B1 B1 B1 B1 A5 8' DBL B1 B1 12 S6.3 TYP 12 S6.3 TYP DBL FJ1 6x10 6x 1 0 HP 5-2 MAX OP WT=807# 12 S9.1 TYP AT SCREENWALL 5'-0"5'-0" SB4 24" MST BENT STRAP, TYP 24" MST BENT STRAP, TYP RJ3 6x10 HDR 6x10 HDR 6x10 HDR 6x10 HDR 6x10 HDR 6x10 HDR 6x 1 0 H D R , T Y P U N O 1'-0" SB3 5 S6.4 TYP 3 S6.4 FJ1 5 1/4"x9 1/2" LVL P11P11 RJ4 KEF 1 MAX OP WT=742# EF 7-6 MAX OP WT=271# SF 7-3 MAX OP WT=235# RJ 4 RJ4 RJ3 DB L DB L PROVIDE DBL JOISTS BENEATH DOAS UNIT PROVIDE SHTG PER NOTE #3 & 7 S6.1 AT RAISED FRAMING OPNG PER 12 S6.1 3 S9.1 TYP PROVIDE SHTG PER NOTE #3 & 7 S6.1 AT RAISED FRAMING FJ1 FJ1 H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 1 H i l t o n A r c a d i a H o t e l ( N e w D e s i g n ) \ 3 _ D r a w i n g s \ D w g s - 0 1 \ 1 9 - 0 2 8 3 - 0 1 _ B l d g D _ S 2 . 6 ( S I X T H F L O O R F R A M I N G P L A N ) . d w g P L O T T E D B Y : Ch a n n o n S h i d a k i O N : Ju n e 1 3 , 2 0 2 4 A T : 11 : 2 1 A M SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME S2.6 SIXTH FLOOR FRAMING PLAN HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 125 W HUNTINGTON DR. BUILDING C & D ARCADIA, CA 91007 VG PROPERTIES INVESTMENTS, LLC NO.DATE ISSUES & REVISIONS S 3900 Cover Street Long Beach, CA 90808 562.985.3200 P TRUC T URAL E N GI N SREE MHP JN 562.985.1011 F 19-0283-01 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) SCALE:S2.6 SIXTH FLOOR FRAMING PLAN A 1/8" = 1'-0" 1.SEE GENERAL NOTES SHEET(S) FOR APPLICABLE NOTES, ABBREVIATIONS AND PLAN SYMBOLS LEGEND. SEE PLAN SHEET FOR LIST OF APPLICABLE TYPICAL DETAILS NOT CALLED OUT ON PLANS. 2.FINISHED SIXTH FLOOR ELEVATION = PER ARCHITECT. 3.UNLESS NOTED OTHERWISE, FLOOR SHEATHING SHALL BE 3/4" STRUCT I TONGUE & GROOVE PLYWOOD, BLOCKED (W/ 2x4 FLAT), W/ 10d NAILS @ 6,6,12 (BN,EN,FN), GLUE PLYWOOD TO JOIST, TYPICAL UNLESS NOTED OTHERWISE. AT INCREASED DIAPHRAGM NAILING AREA, PROVIDE 10D NAILS @ 2", 3'', 12'' (BN, EN, FN). 4.PROVIDE CONSTRUCTION GLUE BETWEEN ALL FLOOR SHEATHING AND BEAMS AND JOISTS. 5.ALL FLOOR MEMBERS NOT OTHERWISE DIMENSIONED SHALL BE EQUALLY SPACED BETWEEN GIRDERS OR OTHER SUPPORTS. 6.FOR FRAMING SPANS GREATER THAN 6'-0", PROVIDE WOOD BLOCKING AT THE LESSER OF MIDSPAN OR 8'-0"OC. INSTALL BLOCKING PER APPLICABLE TYPICAL DETAILS. 7.SEE ARCHITECTURAL PLANS FOR FLOOR DEPRESSIONS AND SLOPES NOT SHOWN ON PLAN. 8.SEE ARCHITECTURAL DRAWINGS FOR NON-BEARING WALL LOCATIONS AND DIMENSIONS NOT SHOWN ON PLAN. 9.LOCATE PLYWOOD ON UNIT SIDE AT CORRIDOR SHEARWALLS. 10.SEE ARCH PLAN FOR WALL STUD THICKNESS. ALL SIXTH FLOOR EXTERIOR WALLS ARE TO BE 2x6 @ 16''OC, INTERIOR BEARING AND SHEAR WALLS TO BE 2x6 STUDS @ 16"OC, UNLESS NOTED OTHERWISE ON PLAN. 11.JAMBS HEADERS AND SILLS NOT SHOWN ON PLAN, TYPICAL UNLESS NOTED OTHERWISE. SEE 4/S6.1 AND 5/S6.1 FOR OPENING FRAMING INFORMATION. 12.SEE SHEET S6.5 FOR TYPICAL DRAG STRAP CONNECTIONS. FRAMING PLAN NOTES FLOOR JOIST SCHEDULE JOIST MARK JOIST SIZE SPACING (UNO) FJ1 9 1/2" RED I 45 16"OC FJ4 DBL 1 3/4"x5 1/2" LVL 16"OC 1.SEE THIRD FLOOR FRAMING PLAN FOR FRAMING SYMBOL LEGEND AND NOTES AS APPLICABLE. 2.SEE GENERAL NOTES SHEET S1.0 FOR APPLICABLE NOTES REGARDING THE VARIOUS CONSTRUCTION ELEMENTS SHOWN ON PLAN. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3.FINISH ROOF ELEVATION = PER ARCH. 4.UNLESS NOTED OTHERWISE, ROOF SHEATHING SHALL BE 5/8" STRUCT I PLYWOOD, BLOCKED, W/ 10d NAILS @ 6",6",12" (BN,EN,FN). 5.ALL FLOOR MEMBERS NOT OTHERWISE DIMENSIONED SHALL BE EQUALLY SPACED BETWEEN GIRDERS OR OTHER SUPPORTS. 6.FOR FRAMING SPANS GREATER THAN 6'-0", PROVIDE WOOD BLOCKING AT THE LESSER OF MIDSPAN OR 8'-0"OC. INSTALL BLOCKING PER APPLICABLE TYPICAL DETAILS. 7.SEE ARCHITECTURAL PLANS FOR ROOF DEPRESSIONS AND SLOPES. 8.UNLESS NOTED OTHERWISE, MAXIMUM OPERATING WEIGHT ROOF TOP MECHANICAL UNITS SHALL BE 250#. PROVIDE DOUBLE JOIST SUPPORT FOR MECHANICAL UNITS EXCEEDING 250# OPERATING WEIGHT. SEE A/S9.1 FOR EQUIPMENT ANCHORAGE SCHEDULE. SEE MECHANICAL DRAWINGS FOR PRECISE SIZE AND LOCATIONS OF MECHANICAL UNITS. 9.SEE ARCHITECTURAL, MECHANICAL, AND/OR ELECTRICAL DRAWINGS FOR LOCATION OF ALL EQUIPMENT. 10.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED WITH ACTUAL EQUIPMENT TO BE INSTALLED. 11.CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF ALL ACCESS PANEL & EQUIPMENT ANCHOR/ MOUNTING HOLES PRIOR TO INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS PROVIDED ON PLANS AND/OR DETAILS, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. SEE 12/S6.1 & 13/S6.1 FOR FRAMING OPENING DETAILS. 12.SEE SHEET S6.5 FOR TYPICAL DRAG STRAP CONNECTIONS. 13.SEE 12 /S9.1 FOR ROOF TOP MECH SCREEN CONNECTION DETAILS ROOF FRAMING PLAN NOTES ROOF BEAM SCHEDULE BEAM MARK JOIST SIZE RB1 5 1/4"x9 1/2" LVL RB4 6x6 ROOF JOIST SCHEDULE JOIST MARK JOIST SIZE SPACING (UNO) RJ3 1 3/4x5 1/2 LVL 24"OC RJ4 9 1/2" RED I-45 24"OC POST SCHEDULE POST MARK POST SIZE P1 6x6 P2 6x4 P3 4x4 P4 4x6 P5 4x8 P6 4x10 P7 6x10 P8 (2)-2x8 P9 (3)-2x8 P10 (4)-2x8 P11 6x8 P12 8x8 STEEL COLUMN SCHEDULE COLUMN MARK COLUMN SIZE REFERENCE DETAIL NOTE C1 HSS5x5x1/4 9/S4.1 OR 2/S6.2, UNO 3/4" THK BASE PL C2 HSS8x6x1/4 STUB COL SEE PLAN COORDINATE LOCATION WITH ELEVATOR C3 HSS5x5x1/4 9/S4.1 1" , TYPE B BASE PL C4 HSS5x5x1/4 9/S4.1 1" , TYPE C BASE PL C5 HSS4x4x1/4 9/S4.1 1" , TYPE C BASE PL C6 HSS5x5x5/16 9/S4.1 1" , TYPE A BASE PL C7 HSS6x4x1/2 FLOOR WOOD BEAM SCHEDULE BEAM MARK BEAM SIZE COMMENTS B1 5 1/4"x9 1/2" LVL TYP, UNO B7 3 1/2"x9 1/2" LVL HANGER NOTE: AT STEEL AND CMU, PROVIDE SIMPSON "W" HANGER EACH END UNLESS NOTED OTHERWISE AT CMU PROVIDE (4)-7/8"Ø AB @ 8"OC EACH SIDE OF BEAM WHERE LEDGER OCCURS. STEEL BEAM SCHEDULE BEAM MARK JOIST SIZE SB1 W8x21 SB2 W8x15 SB3 W8x35 SB4 HSS6x6x1/4 04.02.24 RFI 161 06. .24 RFI 207 RJ 3 TIEBACK LOCATIONS TO BE ATTACHMENT TOSTRUCTURE PER 15/S9.1 AT RJ4 AND SAWN LUMBERJOIST LOCATIONS, AND 14/S9.1 AT RJ3 JOIST LOCATIONS 18 3 1 / 2 " x 5 1 / 4 " L V L 3 1 / 2 " x 5 1 / 4 " L V L WOOD 06/18/2024 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT Exp. 6-30-25 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 09.04.24 RFI 259 15 S6.4 SIM 3 S5.1 TYP3 S5.1 TYP RJ3 ABOVE SHTG PER NOTE #4 & 7 S6.1 ,TYP W8 x 1 5 W8 x 1 5 BE A M HO I S T BE A M HO I S T 15 S6.4 15 S6.4 TYP 15 S6.4 SIM RJ3 HSS5x5x1/4, TYP (3 LOCS) 30 " C L R FR O N T 42 " C L R FR O N T 42 " C L R 42"CLR 30"CLR FRONT 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 30" C L R 42"CLR 30"CLR FRONT DA DG DH DJ DK DL DM DP D7 D8.1 D12 D8.1 D12 DF DG.5 DH.5 DI.5 DK.5 DL.5 DC D8 D10 D11 DB DD DN DE D10 D11 D11.9 SHTG PER NOTE #4 & 7 S6.1 ,TYP 9 S6.4 6 S6.4 8 S6.4 9 S6.4 6x 1 0 H D R , T Y P U N O RJ 4 RJ3 RJ3 RB 1 DB L PROVIDE (2)-ROWS FLOOR SHTG BN ALONG THIS WALL 13 S6.4 TYP RB4 7"x9 1/2" LVL 7" x 9 1 / 2 " L V L 7" x 9 1 / 2 " L V L 7"x9 1/2" LVL RB1 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 SB2 RJ 4 RB 4 RB 4 RJ 4 RJ 4 RJ4 DBL RJ 3 RJ3 RB4 SB2 RJ 4 RB 1 RB1 RB 1 RB 1 RJ 4 RJ 4 SB 1 SB2 SB2 SB 1 RJ 4 RJ 4 B1 FJ4 2x 1 0 @ 1 2 " O C SB2 K S5.3 BELOW C S2.7 STAIR 2 ABOVE 5 S6.4 SB 4 HP 3-1 MAX OP WT=918#RB 1 RB 1 RB 1 RB1RB1 RB1 RB 1 RB 1 RB 1 RB 1 RB 1 HP 4-1 MAX OP WT=918# HP 5-1 MAX OP WT=918# HP 6-1 MAX OP WT=918#HP 114B MAX OP WT=519# HP 114A MAX OP WT=519# RB 1 RB 1 RB 1 RB 1 RB 1 RB 1 RB 1 RB 1 RB1 RB1 RB1 RB1 RB1 RB1 RB 1 RB 1 RB 1 RB 1 GWH PER PLUMBING, MAX OP WT= 1,600# EA HP 115A MAX OP WT=519# RB 1 RB 1 RB 1 RB 1 RB 1 RB 1 RB1 RB1 RB1 RB1 6 S6.4SIM 6x 1 0 6x10 6x 1 0 RJ3 RJ4 24" MST BENT STRAP, TYP SB4 FLOOR OPNG PER 12 S6.1 & 13 S6.1 AS APPLICABLE, TYP 12 S9.1 TYP AT SCREENWALL 2X 1 0 @ 1 2 " O C 24" MST BENT STRAP, TYP 5 S6.4 9 S6.4 B S2.7 ROOF ABOVE 4 S6.4 3 S6.4 6x 1 0 H D R , T Y P U N O 6x10 HDR 6x 1 0 4x10 4x10 8 S6.4 11 S6.4 4 S6.4 3 S6.4 10 S6.4 DB L 2 x 1 0 DB L 9 1 / 2 " RE D I - 4 5 4x10 2x10 @ 12"0C 2x10 @ 12"0C DB L 9 1 / 2 " RE D I - 4 5 HP 701 MAX OP WT=153# RB 1 RB 1 HP 115B MAX OP WT=519# PROVIDE DBL JOISTS BENEATH WATER HEATERS RB 1 RB 1 RB1 RB1 RB1 RJ 4 RJ 4 SF 7-2 MAX OP WT=99# 3 S9.1TYP HP 117 MAX OP WT=393# 2x10 @ 12"0C SF 7-1 MAX OP WT=389# RB4 RB4 RB4 RB4 EF 7-5 MAX OP WT=247# HP IT MAX OP WT=657# RB4 D8.1D8 D10 DC DB DD D8.1 D10 RJ 3 15 S6.4 15 S6.4 SIM DM DP DN H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 1 H i l t o n A r c a d i a H o t e l ( N e w D e s i g n ) \ 3 _ D r a w i n g s \ D w g s - 0 1 \ 1 9 - 0 2 8 3 - 0 1 _ B l d g D _ S 2 . 7 ( R O O F & H I G H E L E V A T O R F R A M I N G P L A N S ) . d w g P L O T T E D B Y : Ch a n n o n S h i d a k i O N : Ju n e 2 7 , 2 0 2 4 A T : 9: 4 6 A M SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME S2.7 ROOF & HIGH ELEVATOR FRAMING PLANS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 125 W HUNTINGTON DR. BUILDING C & D ARCADIA, CA 91007 VG PROPERTIES INVESTMENTS, LLC NO.DATE ISSUES & REVISIONS S 3900 Cover Street Long Beach, CA 90808 562.985.3200 P TRUC T URAL E N GI N SREE MHP JN 562.985.1011 F 19-0283-01 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) SCALE:S2.7 ROOF & HIGH ELEVATOR FRAMING PLANS A 1/8" = 1'-0" ROOF JOIST SCHEDULE JOIST MARK JOIST SIZE SPACING (UNO) RJ3 1 3/4x5 1/2 LVL 24"OC RJ4 9 1/2" RED I-45 24"OC 1.SEE THIRD FLOOR FRAMING PLAN FOR FRAMING SYMBOL LEGEND AND NOTES AS APPLICABLE. 2.SEE GENERAL NOTES SHEET S1.0 FOR APPLICABLE NOTES REGARDING THE VARIOUS CONSTRUCTION ELEMENTS SHOWN ON PLAN. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3.FINISH ROOF ELEVATION = PER ARCH. 4.UNLESS NOTED OTHERWISE, ROOF SHEATHING SHALL BE 5/8" STRUCT I PLYWOOD, BLOCKED, W/ 10d NAILS @ 6",6",12" (BN,EN,FN). 5.ALL FLOOR MEMBERS NOT OTHERWISE DIMENSIONED SHALL BE EQUALLY SPACED BETWEEN GIRDERS OR OTHER SUPPORTS. 6.FOR FRAMING SPANS GREATER THAN 6'-0", PROVIDE WOOD BLOCKING AT THE LESSER OF MIDSPAN OR 8'-0"OC. INSTALL BLOCKING PER APPLICABLE TYPICAL DETAILS. 7.SEE ARCHITECTURAL PLANS FOR ROOF DEPRESSIONS AND SLOPES. 8.UNLESS NOTED OTHERWISE, MAXIMUM OPERATING WEIGHT ROOF TOP MECHANICAL UNITS SHALL BE 250#. PROVIDE DOUBLE JOIST SUPPORT FOR MECHANICAL UNITS EXCEEDING 250# OPERATING WEIGHT. SEE A/S9.1 FOR EQUIPMENT ANCHORAGE SCHEDULE. SEE MECHANICAL DRAWINGS FOR PRECISE SIZE AND LOCATIONS OF MECHANICAL UNITS. 9.SEE ARCHITECTURAL, MECHANICAL, AND/OR ELECTRICAL DRAWINGS FOR LOCATION OF ALL EQUIPMENT. 10.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED WITH ACTUAL EQUIPMENT TO BE INSTALLED. 11.CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF ALL ACCESS PANEL & EQUIPMENT ANCHOR/ MOUNTING HOLES PRIOR TO INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS PROVIDED ON PLANS AND/OR DETAILS, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. SEE 12/S6.1 & 13/S6.1 FOR FRAMING OPENING DETAILS. 12.SEE SHEET S6.5 FOR TYPICAL DRAG STRAP CONNECTIONS. 13.SEE 12 /S9.1 FOR ROOF TOP MECH SCREEN CONNECTION DETAILS ROOF FRAMING PLAN NOTES ROOF BEAM SCHEDULE BEAM MARK JOIST SIZE RB1 5 1/4"x9 1/2" LVL RB4 6x6 SCALE:S2.7 ELEVATOR PENTHOUSE FRAMING PLAN B 1/8" = 1'-0" STEEL COLUMN SCHEDULE COLUMN MARK COLUMN SIZE REFERENCE DETAIL NOTE C1 HSS5x5x1/4 9/S4.1 OR 2/S6.2, UNO 3/4" THK BASE PL C2 HSS8x6x1/4 STUB COL SEE PLAN COORDINATE LOCATION WITH ELEVATOR C3 HSS5x5x1/4 9/S4.1 1" , TYPE B BASE PL C4 HSS5x5x1/4 9/S4.1 1" , TYPE C BASE PL C5 HSS4x4x1/4 9/S4.1 1" , TYPE C BASE PL C6 HSS5x5x5/16 9/S4.1 1" , TYPE A BASE PL C7 HSS6x4x1/2 LIST OF APPLICABLE TYPICAL FRAMING DETAILS DESCRIPTION DETAIL SHEET TYPICAL BEAM CONNECTION SCHEDULE 1 S5.1 TYPICAL BEAM TO BEAM CONNECTION 2 S5.1 TYPICAL BEAM TO COLUMN CONNECTION 3 S5.1 TYPICAL STIFFENER PLATE 4 S5.1 TI FRAMING AT STEEL BEAM 5 S5.1 WOOD BEAM TO STEEL COLUMN 7 S5.1 TYPICAL BEAM TO BEAM MOMENT CONNECTION 8 S5.1 TYPICAL WOOD BEAM TO WOOD BEAM CONNECTION 1 S6.1 TYPICAL JOIST TO WOOD BEAM CONNECTION 2 S6.1 WOOD POST BASE TO CONCRETE 3 S6.1 TYPICAL OPENING IN EXTERIOR WOOD STUD WALL 4 S6.1 TYPICAL OPENING IN INTERIOR WOOD STUD WALL 5 S6.1 WOOD STUD WALL TO CONCRETE 6 S6.1 TYPICAL HORIZONTAL PLYWOOD SHEATHING 7 S6.1 WOOD POST TO BEAM CONNECTION WITHIN WALL 8 S6.1 TYPICAL WOOD NAILER AT STEEL BEAM 9 S6.1 DOUBLE TOP PLATE SPLICE SCHEDULE 10 S6.1 TYPICAL WOOD BEAM HANGER SCHEDULE 11 S6.1 TYPICAL HORIZONTAL FRAMING AT OPENING BETWEEN JOIST OR RAFTER (2'-0" MAX)12 S6.1 TYPICAL HORIZONTAL FRAMING AT OPENING (4'-0" MAX)13 S6.1 TYPICAL WOOD BEAM TO ISOLATED WOOD POST 14 S6.1 NON-BEARING PARTITION 15 S6.1 TYPICAL WOOD STUD WALL BLOCKING / BACKING 16 S6.1 TYPICAL DOUBLE PLYWOOD WEB JOIST 17 S6.1 TYPICAL HOLES AND NOTCHES IN WOOD 18 S6.1 HOLE IN BEAMS 19 S6.1 TYPICAL BEAM IN WALL 20 S6.1 TYPICAL MULTI-STORY SHEAR WALL ELEVATION, SCHEDULE AND NOTES A S6.2 DETAIL 1 S6.2 HSS OR PIPE COLUMN IN SHEAR WALL 2 S6.2 HOLDOWN AT UPPER FLOORS 3 S6.2 TYPICAL CORNERS AND INTERSECTIONS AT WOOD STUD SHEAR WALLS 4 S6.2 TYPICAL ATS ELEVATION VIEW AND ALLOWABLE PENETRATION AT SHEAR WALL 5 S6.2 TYPICAL STRINGER TO FRAMING CONNECTION 13 S6.3 FRAMING STRAP OVER TOP OF PLYWOOD 15 S6.3 TYPICAL I-JOIST WEB STIFFENER 17 S6.3 STEEL BEAM SCHEDULE BEAM MARK JOIST SIZE SB1 W8x21 SB2 W8x15 SB3 W8x35 SB4 HSS6x6x1/4 SCALE:S2.7 STAIR 2 - PENTHOUSE FRAMING PLAN C 1/8" = 1'-0" 04.02.24 RFI 161 07.01.24 RFI 216 Exp. 6-30-25 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 07/01/2024 DB L 4x10 PROVIDE SIMP HWP HANGER WHERE INDICATED 2X10 @ 12" OC, TYP, 4X10 @ 12" 0C AT EBM FULCRUMLOCATIONS (4 MIN), PROVIDE SIMP HWP HANGER AT4x10 JOSTS ATTACHED TO Wx PROVIDE SIMP LGU5.25-SDS AT DBL JOIST END TIEBACK LOCATIONS TO BE ATTACHMENT TO STRUCTURE PER 15/S9.1 AT RJ4 AND SAWN LUMBER JOIST LOCATIONS, AND 14/S9.1 AT RJ3 JOIST LOCATIONS WOOD PLACE A DBL JOIST 1 FOOT AWAY FROM EXTERIOR WALL(IN ADDITION TO TYP ROOF JOISTS), TYP NEXT TO WALL ALONG GL D12 AS SHOWN (9 LOCS) WOOD DB L DB L DB L DB L DB L DB L DB L DB L WOOD TYP, 4X10 @ 12" 0C AT EBMFULCRUM LOCATIONS (4 MIN), ATTACH TODBL WITH SIMP LGU3.63-SDS. TYP AT JOISTSBELOW GL DL, UNO TIEBACK LOCATIONS TO BE ATTACHMENT TO STRUCTURE PER 15/S9.1 AT RJ4 AND SAWN LUMBER JOIST LOCATIONS, AND 14/S9.1 AT RJ3 JOIST LOCATIONS 09.04.24 RFI 259 A PE R S C H E D SEISMIC CRADLE CLIP OR U-BOLT PER PLAN VIEW A-A (2 MIN) A PE R S C H E D P1000T STRUT PER PLAN VIEW A-A EQUIP MOUNT AS OCCURS PER APPLICABLE DETAIL COUPLER AND/OR SPRING ISOLATOR WHERE OCCURS A PE R S C H E D , T Y P THREADED ROD PER APPLICABLE DETAIL SUPPORTING MEMBER PER APPLICABLE DETAIL 2"MI N TY P AA PLAN VIEW A-A STIFFENER TYPE A FOR 3/8"Ø, 1/2"Ø, OR 5/8"Ø RODS STIFFENER TYPE B FOR 3/4"Ø, 7/8"Ø, OR 1"Ø RODS PL1/4 x1 5/8 x0'-3 1/2" P1000T STRUT U-BOLT (FIT TIGHT TO STRUT & HANGER ROD) THREADED ROD 3/8"Ø BOLT P1000T STRUT THREADED ROD P2485 CRADLE CLIP P3008 NUT STIFFENER SCHEDULE ROD DIAMETER STIFFENER TYPE A (MAX) 3/8" TYPE A 9" 1/2"12" 5/8"15" 3/4" TYPE B 20" 7/8"25" 1"28" NOTE: ALL CHANNELS, BRACKETS AND FASTENERS NOTED AS “P####” ARE BY UNISTRUT. SCALE:S9.1 TYPICAL HANGER ROD STIFFENER OPTIONS 13 NONE UNIT ANCHORAGE SCHEDULE UNIT NAME DISCIPLINE (A/M/E/P)REF DETAIL MAX OP WT MSD E 1/S9.1 2,800 LVC1, LVD1 & TRANSFORMER E 2/S9.1 1,000# DOAS-1 M 11/S9.1 PER PLAN HP, SF, WH, EF, KEF M 11/S9.1 PER PLAN GWH P 3/S9.1 PER PLAN SCALE:S9.1 EQUIPMENT SCHEDULE A 1" = 1'-0" BLKG AT I-JOIST BLKG AT 2x JOIST 1" EQ EQ 1" HANGER ROD TO STRUCTURE GAUGE STRAP TO STRUCTURE CABLE BRACE TO STRUCTURE BLKG PER 4 S9.1 FRAMING OR BLKG PER 4 S9.1 , TYP 3" 1" M I N HANGER ROD TO STRUCT ALT 3/4"Ø THRU BOLT HGR ROD PER MECH PLY ROOF AS OCCURS (3)-10d NAILS ANGLE BRACE TO STRUCTURE PLY ROOF AS OCCURS (3)-10d NAILS PLY ROOF AS OCCURS JOIST PER PLAN FILLER PER 6 S9.1 2x OR I-JOIST PER PLAN FILLER PER 17 S6.3 SCALE:S9.1 BLOCKING AT STRUCTURE FOR MECHANICAL ANCHORAGE 4 1" = 1'-0" SCALE:S9.1 TJI BLOCKING DETAIL 5 1" = 1'-0" SCALE:S9.1 EQUIPMENT ANCHORAGE TOP CONNECTIONS 6 1" = 1'-0" 3" SOLID WEB FILLER BOTH SIDES (12" LONG MIN, 1" THK MIN) (4)-ROWS 8d @ 4"OC EA SIDE (STAGG BTWN SIDES) 4x4 MIN BLKG W/ SIMP 'U' HANGER EA END DBL JOIST PER PLAN 4x4 MIN BLKG W/ SIMP 'U' HANGER EA END I-JOIST PER PLAN 1/4" GAP T&B, TYP TJI BLKG W/ SIMP A35 EA END STAGGER TO WEB STIFF, TYP FULL HT 4x BLK W/ SIMP A35 EA END EA SIDE 2x OR I-JOIST PER PLAN (2)-1/2"Ø x3" LAG SCREWS ANGLE BRACE (L2x2x12GA MINx6'-0'' LONG MAX) PER MECH 100 LBS MAX (3)-#10 x2" WOOD SCREWS MIN SUPPORT STRAP (20GAx2'' MIN) PER MECH (TWIST STRAP 90º AS REQD) 2x OR I-JOIST PER PLAN HANGER ROD PER MECH NUT & WASHER ABOVE & BELOW 100# MAX 100# MAX JOIST OR 4x BLKG AS OCCURS L2 1/2x2x3/8 x0'-3" LONG ANGLE BRACE FULL HT 4x BLK W/ U-HANGER EA END 2x OR I-JOIST PER PLAN (4)-TIGHT TURNS IN 1 1/2" CABLE BRACE PER MECH 100# MAX UNISTRUT P1354A W/ (2)-1/2"Ø x3" LAG SCREWS SCALE:S9.1 PREFAB CURB TO WOOD FRAMING 11 NONE PE R A P P L I C A B L E DE T A I L 1" MAX 1" MIN STRAP TO CURB WELD PER APPLICABLE DETAIL UNIT PER APPLICABLE DETAIL SEISMIC STRAP PER MECH, CONN TO FRAME & CURB W/ BOLT & WELD PER APPLICABLE DETAIL PRE-FABRICATED ROOF CURB (12GA MIN)SDS25412 @ 16"OC ALL AROUND WELDED UNIT FRAME (12GA MIN) WELDED UNIT FRAME (Cx W/ 3/16" MIN THK WEB & Lx) CHANNEL FRAME CONDTION (E) PLY SHEATHING PER PLAN CURB TO WOOD FRAMING SECTION A-A SEISMIC STRAP PER MECH, CONN TO FRAME & CURB W/ SMS PER APPLICABLE DETAIL ROOF BEAM, JOIST OR BLOCKING AS OCCURS 2 1/2" MIN TYP A A ROOF BEAM, JOIST OR BLOCK LAG SCREW, CURB TO WOOD FRAMING BLOCK PER APPL DETAIL (4x6 MIN UNO) W/ SIMP A35 EA SIDE, EA END, TYP SCALE:S9.1 SCREEN WALL 12 NONE 1' - 6 " MA X VA R I E S 1'- 0 " MA X 1'- 0 " MA X 2/ 3 H ± 4 " 1/ 3 H ± 4 " H = 8 ' - 6 " M A X BBBB A A A A 8" 5" 1" TY P 1" TYP SECTION B-BSECTION A-A BRACE DIRECTION 3" MIN TYP FURRING CHANNEL PER ARCH PL1/4 CAP SCREEN PER ARCH HSS3x3x1/4 (8'-0'' OC MAX) HSS2x2x1/8 BRACE 3/16 PL3/8 W/ (4)-SIMP SDS25412 SCREWS W/ 4'' MIN END DISTANCE & 2'' MIN EDGE DISTANCE AT BLKG CJP 1 1/2 " MIN 1 1/2 " MIN TY P 6x6 BLKG W/ SIMP A35 EA SIDE, EA END, CTRD BELOW EA SET OF SCREWS AT BRACE, TYP 6x10 FLAT BLKG CENTERED BELOW SCREWS AT POST W/ SIMP A34 EA SIDE, EA END DBL 2x OR DBL I-JOIST EA SIDE OF SCREEN POST 3/16 CAP PL TO POST, TYP PLWD SHTG PER PLAN (E) PLYWOOD SHEATHING PER PLAN BLKG CENTERED BELOW SCREWS HSS3x0.25 @ 8'-0" MAX (E) WOOD JOIST PER PLAN ROOFING PER ARCH PL3/8 GUSSET W/ 7/8"Ø THRU BOLT WP 30º M I N 60º M A X CONDITION A PERP ROOF JOISTS BBBB FURRING CHANNEL PER ARCH SCREEN PER ARCH HSS HSS BRACE PLWD SHTG PER PLAN ROOFING PER ARCH CONDITION B PERP ROOF JOISTS NOTE: FOR BALANCE OF INFO NOT SHOWN, SEE COND A DBL I-JOIST EA SIDE OF SCREEN POST BBBB A A A A FURRING CHANNEL PER ARCH SCREEN PER ARCH HSS HSS2x2x1/8 BRACE PLWD SHTG PER PLAN ROOFING PER ARCH CONDITION C TOP OF WALL WEB STIFF PER 17 S6.3 6x6 BLKG EA SIDE W/ A34 EA SIDE EA END ADDL SIMP H2A NOTE: FOR BALANCE OF INFO NOT SHOWN, SEE COND A WHERE ROD EXCEEDS 14'', PROVIDE ROD STIFF PER 13 S9.1 WHERE REQD 100# MAX WHERE ROD EXCEEDS 14'', PROVIDE ROD STIFF PER 13 S9.1 WHERE REQD 100# MAX SCALE:S9.11" = 1'-0" SCALE:S9.1 TIEBACK ANCHOR AT ROOF 15 NONE PL3/8x4x4 12 " MI N 1/4 1/4 ROUND HSS3x0.25ROUND HSS3x0.25 TYP 9" 9" 1 1/2" TYP 1 1 / 2 " TY P PER PLAN 1 1 / 2 " TY P PLAN VIEW DBL JOIST EA SIDE OF TIE BACK ANCHOR JOIST PER PLAN TIEBACK AND BASE PL PER OTHERS 5 1/4" x 7 1/4" LVL BLKG W/ SIMP HGUS5.5/8 HGR EA END, TYP SIMP MST72 STRAP TO BLKG EA SIDE OF TIEBACK 2' - 0 " M A X BLKG PER PLAN VIEW JOIST PER PLAN DBL JOIST EA SIDE OF TIE BACK ANCHOR PLWD SHTG PER PLAN TIEBACK (4)-3/4"Ø THRU BOLTS TO BLKG BELOW SIMP STRAP 30d @ 6"OC, TYP 30d @ 6"OC, TYP 30d @ 6"OC, TYP SCALE:S9.1 RECESSED PANEL ANCHORAGE 10 NONE (E) WOOD STUD (2x6 MIN) WALL PER PLAN HEADER & JAMB PER 4 S6.1 OR 5 S6.1 W MAX H MA X (2)-1/4"Ø WOOD SCREWS, TYP EA SIDE AS SHOWN (4 SCREWS TOTAL) PANEL BOARD PER PLAN, MAX OP WT PER PLAN CONDUIT WHERE OCCURS ADD STRAPS AT DBL TOP PL AS REQD PER 18 S6.1 NOTE: FOR BALANCE OF INFO SHOWN BUT NOT NOTED, SEE 4 S6.1 OR 5 S6.1 SCALE:S9.1 MECH PLATFORM AT TRUSS JOIST 3 NONE PER MECHANICAL 2 3/4" MIN TYP 2"2"2" MAX TYP 2"2" 2" MAX TYP 1'- 0 " MA X SECTION A-A A A JOIST PER PLAN L3x3x1/4x0'-6" LONG BENT PL (2 EA CORNER) W/ (2)-#12 SMS TO UNIT & (2)-3/8"Ø LAG SCREWS (3" PEN) TO SLEEPER, TYP 4x SLEEPER ALL AROUND AND @ 8'-0" MAX, FIELD VERIFY DEPTH 2x6 @ 16"OC W/ SIMP LUS HGR, TYP 6x6 BLOCK W/ SIMP FACE MOUNT HANGER, TYP MECH UNIT PER PLAN ROOF SHEATHING PER PLAN 2x6 BLKG JOIST PER PLAN, TYP L3x3x1/4x0'-6" LONG BENT PL W/ (2)-3/8"Ø x3'' LONG LAG SCREWS TO SLEEPER & 6x6, TYP 3/4" PLWD, BLOCKED W/ 10d @ 6",6",12" (BN,EN,FN), TYP BN BN EN EN (2)-A34 EA CORNER A35 @ 12''OC LARGER PLATFORM WHERE OCCURS LARGER PLATFORM WHERE OCCURS SCALE:S9.1 ELECTRICAL EQUIPMENT ANCHORAGE 2 NONE H MA X 21 " MI N W MIN PLAN VIEW AT BASE CONC SLAB ON GRADE PER PLAN CONC HOUSE KEEPING PAD PER 20 S4.1 ANCHOR PER PLAN VIEW, TYP EQUIPMENT PER PLAN, MAX OP WT PER A S9.1 5/8"Ø EXPANSION ANCHOR (3 5/8" EMBED) IN MANUF PREDRILLED HOLE, TYP AT EA CORNER AS SHOWN (4 ANCHORS TOTAL) 6" MIN TYP ALL AROUND SCALE:S9.1 ELECTRICAL SWITCHBOARD ANCHORAGE 1 NONE H MA X PLAN VIEW AT BASE CONC SLAB ON GRADE PER PLAN CONC HOUSE KEEPING PAD PER 20 S4.1 ANCHOR PER PLAN VIEW, TYP EQUIPMENT PER PLAN, MAX OP WT PER A S9.1 5/8"Ø EXPANSION ANCHOR (3 5/8" EMBED) IN MANUF PREDRILLED HOLE, TYP AT EA CORNER AS SHOWN (4 ANCHORS TOTAL) 6" MIN TYP ALL AROUND 2'-7"1'-4" A A SECTION A-A 1'- 9 " 1 1 / 2 " 2 1/2" 3'-0"2'-0"2'-0"4'-0" 1'-4"3'-7" AIRCRAFT CABLE TO CONCRETE SLAB 1 1 250# MAX NOTES: 1.FOR TELECOM AND ELECTRICAL CABLE TRAYS (MAX WT=10 LBS/FT) SPACE VERTICAL ROD @ 60"OC MAXIMUM. 2.PROVIDE PIPE AND CABLE TRAY AIRCRAFT CABLE BRACING EA SIDE SPACED AT 10'-0"OC MAXIMUM TRANSVERSE AND LONGITUDINAL. 3.MINIMUM SPACING BETWEEN HANGER OR BRACE CONNECTION. 3/8"Ø HILTI KB-TZ (1 1/2" EMBED)UNISTRUT P1546 OR EQUAL 3/16" GALVANIZED AIRCRAFT CABLE W/ 2-U-BOLT CLAMPS & THIMBLE CONC SLAB PER PLAN 250# MAX 3/8"Ø HILTI KB TZ (1 1/2" MIN EMBED) ALT TO KB-TZ: CAST IN HEADED ANCHOR BOLT (2" EMBED) W/ DIAMETER TO MATCH HANGER ROD3/8"ØA36 THREADED ROD. FOR PIPE HANGERS AT 5"-8"Ø PIPES, USE 1/2"Ø A36 ROD. WHERE ROD LENGTH AT BRACE IS GREATER THAN 14" PROVIDE STIFFENER PER 13 S9.1 3/8"Ø COUPLER CONC SLAB PER PLAN SCALE:S9.1 SUSPENDED DISTRIBUTION SYSTEMS (MEP OR ARCHITECTURAL ELEMENTS)7 1/2" = 1'-0" SCALE:S9.1 TYPICAL ROOFTOP DUCT SUPPORT 8 NONE 4'- 6 " M A X 6'- 6 " M A X 9'-0" MAX 5/16 TYP 5/16 TYP 5/16 TYP C6x8.2 DUCT PER MECH 3" STD PIPE @ 9'-0"OC MAX, TYP C6x8.2 DBL JOIST OR DECREASE JOIST SUPPORT TO 12''OC AT DUCT SUPPORT PLY SHEATHING PER PLAN AA 2" TYP PLAN VIEW A-A PL1/2x4x0'-10" BASE PLATE W/ (4)-SIMP SDS25500 SCREWS SCALE:S9.1 PANEL BOARD ANCHORAGE 9 NONE W MAX (EQUAL TO (E) STUD SPACING) D MAX H MA X 2" MA X 2" MA X WHERE ANCHOR POINTS DO NOT ALIGN W/ STUDS, PROVIDE WOOD BLOCKING/ BACKING PER 16 S6.1 FINISH AS OCCURS PER ARCH PANEL BOARD PER PLAN, MAX OP WT PER PLAN WOOD STUD (2x6 MIN) WALL PER PLAN (4)-#14 x3" WOOD SCREWS EA SIDE, INTO EA STUD, TYP AS SHOWN (8 SCREWS TOTAL)- AT CONC OR SOLID GROUTED CMU WALL, USE (4)-3/8"Ø HILTI KH-EZ SCREW ANCHOR (3 1/4" EMBED), TYP EA SIDE AS SHOWN (8 SCREWS TOTAL) SIDE ELEVATIONFRONT ELEVATION HANGER STRAP OR COMP STRUT TO CONC SLAB PL1/8x3SQ PLATE WASHER BEND STRAP/STRUT TO FIT (BEND ONE TIME MAX) HANGER STRAP (20GAx2'' MIN) OR COMPRESSION STRUT (362S162-33 MIN) HANGER ROD TO CONC SLAB (2)-1/4''Ø SMS EA CORNER 1" 1" 6x BLKG PER ABOVE WEB STIFF PER 17 S6.3 6x12 BLKG CTR BELOW POST W/ A35 EA END 250# MAX 250# MAX H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 1 H i l t o n A r c a d i a H o t e l ( N e w D e s i g n ) \ 3 _ D r a w i n g s \ D w g s - 0 1 \ 1 9 - 0 2 8 3 - 0 1 _ B l d g D _ S 9 . 1 ( E Q U I P M E N T A N C H O R A G E A N D M E P S U P P O R T D E T A I L S ) . d w g P L O T T E D B Y : Ch a n n o n S h i d a k i O N : Ju n e 1 3 , 2 0 2 4 A T : 11 : 2 1 A M SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME S9.1 EQUIPMENT ANCHORAGE DETAILS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 125 W HUNTINGTON DR. BUILDING C & D ARCADIA, CA 91007 VG PROPERTIES INVESTMENTS, LLC NO.DATE ISSUES & REVISIONS S 3900 Cover Street Long Beach, CA 90808 562.985.3200 P TRUC T URAL E N GI N SREE MHP JN 562.985.1011 F 19-0283-01 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) 06. .24 RFI 20718 TIEBACK ANCHOR AT LVL JOISTS 9" PER PLAN 9" 1 1/2" TYP 1 1 / 2 " T Y P PLAN VIEW TY P 5 1/4" x 5 1/4" LVL BLKG W/ SIMP FACE MOUNT HANGER, TYP (4)-3/4" DIA THRU BOLTS AT LVL BEAMS BELOW TIEBACK AND BASE PL PER OTHERS PLWD SHTG PER PLAN SIMP MST72 STRAP TO BLKG EA SIDE OF TIEBACK SIMP MST72 STRAP TO BLKG EA SIDE OF TIEBACK JOIST PER PLAN 3.5 x 5.25 LVL AT ANCHOR BOLT LOCATIONS TIEBACK AND BASE PL PER OTHERS 2'- 0 " M A X 5 1/4" x 5 1/4" LVL BLKG W/ SIMP FACE MOUNT HANGER, TYP JOIST PER PLAN 3.5 x 5.25 LVL AT ANCHOR BOLT LOCATIONS 14 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 06/18/2024 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT Exp. 6-30-25 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 09.04.24 RFI 259 MHP JN: 19-0283-02 123 W. Huntington Dr. Arcadia, CA for VG Property Investments, LLC August 25 E. Huntington Dr Arcadia, CA by MHP, Inc. Structural Engineers Long Beach, California STRUCTURAL CALCULATIONS for Hilton - Arcadia Cover Page 28, 2024 Exp. 6-30-25 S No.4101IS GE R OF C TA ST E R EF D P R O TE E I R E E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DEL L U R A LTSRUCT Exterior Building Mantainance Calcs CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com TOC Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH Table of Contents Section Page No. GENERAL Loading Criteria 1.1 Roof Key Plans 1.2-1.3 Roof Framing Checks 2.1.1-2.1.23 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 1.1 Roof Dead Load = 18psf Roof Live Load = 20psf Tieback Load (Loads are not be considered concurrently): Lateral Load at Tieback = 5000# x 2ft / 0.75' / 2 Anchors = 6667# Vertical Load due to outrigger = 2700#/4 Anchors = 675# Bearing Plate Load at Front Fulcrum: P = 6700#/2legs = 3350# Q = 3350#/(1.5ftx1.5ft) = 1490psf SCALE:S9.1 TIEBACK ANCHOR AT ROOF 15 NONE 9" 9" 1 1/2" TYP 1 1 / 2 " TY P PER PLAN 1 1 / 2 " TY P PLAN VIEW DBL JOIST EASIDE OF TIE BACK ANCHOR JOIST PER PLAN TIEBACK AND BASE PL PER OTHERS 5 1/4" x 7 1/4" LVL BLKGW/ SIMP HGUS5.5/8 HGR EA END, TYP SIMP MST72 STRAP TO BLKG EA SIDE OF TIEBACK 2'-0 " M A X BLKG PER PLAN VIEW JOIST PER PL DBL JOIST EASIDE OF TIE BACK ANCHOR PLWD SHTG PER PLAN TIEBACK (4)-3/4"Ø THRU BOLTS TO BLKG BELOW SIMP STRAP 30d @ 6"OC, TYP Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH Loading Criteria: 6667#6667# 4'-6" MAX (2) RIGGING PLATE, 5x5 12FT 5x5 BEAM, F/R BEAM END STOP PRIMARY SUSPENSION LINE CAPACITY 1,000 LB LOAD SECONDARY LINE SUSPENSION SEE DRAWING L1005-292 FOR PROPER TENSIONING PROCEDURE. MAXIMUM (2) ADJUSTABLE CASTER DOLLY, 5x5 F/R EXISTING ANCHOR 6'-9" MIN(10'-0" REF.) 4'0" MAX MAXIMUM ULTIMATE FULCRUM LOAD = 6,700 LB 3,350 LB PER LEG) MAXIMUM COUNTERWEIGHTLOADING OF 2,700 LB APPLIED TO STRUCTURE1490 psf 9" PER PLAN 9" 1 1/2" TYP 1 1/2" TYP PLAN VIEW 0'-1 1/2"TYP 5 1/4" x 5 1/4" LVL BLKG W/ SIMPFACE MOUNT HANGER, TYP (4)-3/4" DIA THRU BOLTSAT LVL BEAMS BELOW TIEBACK AND BASE PL PER OTHERS PLWD SHTG PER PLAN SIMP MST72 STRAP TOBLKG EA SIDE OF TIEBACK SIMP MST72 STRAP TOBLKG EA SIDE OF TIEBACK JOIST PER PLAN 3.5 x 5.25 LVL ATANCHOR BOLTLOCATIONS TIEBACK AND BASEPL PER OTHERS 2'-0 " M A X 5 1/4" x 5 1/4" LVL BLKG W/ SIMP FACE MOUNT HANGER, TYP JOIST PER PLAN3.5 x 5.25 LVL ATANCHOR BOLT LOCATIONS 5000# Typ Condition @ TJI and Sawn Lumber Typ Condition @ LVL Note About Load Duration Factors: In most calculations the Load Duration Factor (Cd) is taken as 2.0 for loads applied by the tiebacks or the bearing load of the outrigger. This is done because these ultimate loads occur over very short periods of time. For some joist a more conservative value of Cd (1.6) was used. Vertical Load = 2700#/4 Anchors = 675# DICAPAD D1818 1-1/2" = 1'-0"3 1'-6" 1'-6" 1" HIGH DENSITY THERMOPLASTIC PLAN NOTES: 1. PADS TO BE PLACED UNDER FRONT FULCRUM OF PORTABLE OUTRIGGER TO PREVENT DAMAGE TO ROOF HANDLE A DA DG DH DJ DK DL DM DP D1 D2 D5 D7 D8.1 D12 D8.1 D12 D5.5 DF DG DH DJ DK DL DM DP DF DA DC DC D3 D4 D6 D8 D10 D11 DBDB DD DD.2 DNDN DE D10 D11 D11.9 DD D3.1 DE.5 DE.5 DF.5 DF.5 D11.5 D11.5D7 DD.5DD.5 DC.5DC.5 DB.4 DN UP FRONT 42" CLR 30" CLR 42 " C L R 30" C L R FR O N T 42 " C L R 30 " C L R FR O N T FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R DN A DA DG DH DJ DK DL DM DP D1 D2 D5 D7 D8.1 D12 D8.1 D12 D5.5 DF DG DH DJ DK DL DM DP DF DA DC DC D3 D4 D6 D8 D10 D11 DBDB DD DD.2 DNDN DE D10 D11 D11.9 DD D3.1 DE.5 DE.5 DF.5 DF.5 D11.5 D11.5D7 DD.5DD.5 DC.5DC.5 DB.4 HP 2-1 MAX OP WT=657#RJ4 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 FJ 1 SHTG PER NOTE #3 & 7 S6.1 ,TYP B S3.1 MF2 12 S6.3TYP 12 S6.3TYP 12 S6.4 5 S6.4 TYP 9 S6.4 TYP 8 S6.4 TYP 5 S6.4 DBLDBLDBL B1 FJ 4 ROOF SHTG PER ROOF FRMG PLAN NOTE #4 DBL DBL DBL 6 S6.3 TYP 3 S6.3TYP12 S6.3TYP H S5.3 STAIR 2 CMST12 CMST12 STRAP B1 CMST12 STRAP x 20'-0" RJ4 FJ4 FJ4 DB L FJ 1 FJ 1 FJ 1 B7 B7 FJ4 B7 DBL FJ 4 A5 31' A5 17.5' A5 29.5' A5 18' A5 18' A5 17.5' A5 17.5' A5 17.5' A5 9.5' A5 17.5' A5 17.5' A5 29.5' A5 8' A5 29.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' B6 5.5' A6 5.5' A6 5.5' A6 5.5' A5 9' A5 29.5' A6 5.5' A6 5.5' A6 5.5' A5 17.5' A5 17.5' A5 9' FLOOR OPNG PER 12 S6.1 & 13 S6.1 AS APPLICABLE, TYP B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 B1 8x 8 RJ4 RJ4RJ4RJ4 RJ4 A5 17.5' A5 9' A5 17.5' A5 9' B1 B1 B1 B1 B1 SB1 B1B1 B1 A6 5.5' FJ4 SB1 DBL B1 B1 A5 28' FJ 1 FJ 1 SB 3 SB3 SB3 FJ 1 FJ4 B6 5.5' FJ4 FJ 1 SB1 FJ 1 FJ 1 FJ1 A5 17.5' A5 9' A5 9' A5 17.5' A5 27.5' A5 15' A5 16.5'A5 16' A5 5.5' A5 5.5' B6 5.5' B6 5.5' J S5.3 STAIR 2 D S5.4 STAIR 5 A5 30.5' B1 FJ 1 SB 3 B1 HP 1-1 MAX OP WT=657# HP 113C MAX OP WT=393#HP 113B MAX OP WT=519# HP 113B MAX OP WT=519# HP 4-2 MAX OP WT=810# HP 3-2 MAX OP WT=810# DOAS 1 MAX OP WT=2,622# +400# CURB DB L 7" x 9 1 / 2 " L V L 7"x9 1/2" LVL 7" x 9 1 / 2 " L V L 7"x9 1/2" LVL DB L SB 4 DBL A5 18' 6x10 HDR, TYP UNO B1 B1 B1 B1 A5 8' DBL B1 B1 12 S6.3 TYP 12 S6.3 TYP DBL FJ1 6x10 6x 1 0 HP 5-2 MAX OP WT=807# 12 S9.1 TYP AT SCREENWALL 5'-0"5'-0" SB4 24" MST BENT STRAP, TYP 24" MST BENT STRAP, TYP RJ3 6x10 HDR 6x10 HDR 6x10 HDR 6x10 HDR 6x10 HDR 6x10 HDR 6x 1 0 H D R , T Y P U N O 1'-0" SB3 5 S6.4 TYP 3 S6.4 FJ1 5 1/4"x9 1/2" LVL P11P11 RJ4 KEF 1 MAX OP WT=742# EF 7-6 MAX OP WT=271# SF 7-3 MAX OP WT=235# RJ 4 RJ4 RJ3 DB L DB L PROVIDE DBL JOISTS BENEATH DOAS UNIT PROVIDE SHTG PER NOTE #3 & 7 S6.1 AT RAISED FRAMING OPNG PER 12 S6.1 3 S9.1 TYP PROVIDE SHTG PER NOTE #3 & 7 S6.1 AT RAISED FRAMING FJ1 FJ1 H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 1 H i l t o n A r c a d i a H o t e l ( N e w D e s i g n ) \ 3 _ D r a w i n g s \ D w g s - 0 1 \ 1 9 - 0 2 8 3 - 0 1 _ B l d g D _ S 2 . 6 ( S I X T H F L O O R F R A M I N G P L A N ) . d w g P L O T T E D B Y : Ch a n n o n S h i d a k i O N : Ju n e 1 3 , 2 0 2 4 A T : 11 : 2 1 A M SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME S2.6 SIXTH FLOOR FRAMING PLAN HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 125 W HUNTINGTON DR. BUILDING C & D ARCADIA, CA 91007 VG PROPERTIES INVESTMENTS, LLC NO.DATE ISSUES & REVISIONS S 3900 Cover Street Long Beach, CA 90808 562.985.3200 P TRUC T URAL E N GI N SREE MHP JN 562.985.1011 F 19-0283-01 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) SCALE:S2.6 SIXTH FLOOR FRAMING PLAN A 1/8" = 1'-0" 1.SEE GENERAL NOTES SHEET(S) FOR APPLICABLE NOTES, ABBREVIATIONS AND PLAN SYMBOLS LEGEND. SEE PLAN SHEET FOR LIST OF APPLICABLE TYPICAL DETAILS NOT CALLED OUT ON PLANS. 2.FINISHED SIXTH FLOOR ELEVATION = PER ARCHITECT. 3.UNLESS NOTED OTHERWISE, FLOOR SHEATHING SHALL BE 3/4" STRUCT I TONGUE & GROOVE PLYWOOD, BLOCKED (W/ 2x4 FLAT), W/ 10d NAILS @ 6,6,12 (BN,EN,FN), GLUE PLYWOOD TO JOIST, TYPICAL UNLESS NOTED OTHERWISE. AT INCREASED DIAPHRAGM NAILING AREA, PROVIDE 10D NAILS @ 2", 3'', 12'' (BN, EN, FN). 4.PROVIDE CONSTRUCTION GLUE BETWEEN ALL FLOOR SHEATHING AND BEAMS AND JOISTS. 5.ALL FLOOR MEMBERS NOT OTHERWISE DIMENSIONED SHALL BE EQUALLY SPACED BETWEEN GIRDERS OR OTHER SUPPORTS. 6.FOR FRAMING SPANS GREATER THAN 6'-0", PROVIDE WOOD BLOCKING AT THE LESSER OF MIDSPAN OR 8'-0"OC. INSTALL BLOCKING PER APPLICABLE TYPICAL DETAILS. 7.SEE ARCHITECTURAL PLANS FOR FLOOR DEPRESSIONS AND SLOPES NOT SHOWN ON PLAN. 8.SEE ARCHITECTURAL DRAWINGS FOR NON-BEARING WALL LOCATIONS AND DIMENSIONS NOT SHOWN ON PLAN. 9.LOCATE PLYWOOD ON UNIT SIDE AT CORRIDOR SHEARWALLS. 10.SEE ARCH PLAN FOR WALL STUD THICKNESS. ALL SIXTH FLOOR EXTERIOR WALLS ARE TO BE 2x6 @ 16''OC, INTERIOR BEARING AND SHEAR WALLS TO BE 2x6 STUDS @ 16"OC, UNLESS NOTED OTHERWISE ON PLAN. 11.JAMBS HEADERS AND SILLS NOT SHOWN ON PLAN, TYPICAL UNLESS NOTED OTHERWISE. SEE 4/S6.1 AND 5/S6.1 FOR OPENING FRAMING INFORMATION. 12.SEE SHEET S6.5 FOR TYPICAL DRAG STRAP CONNECTIONS. FRAMING PLAN NOTES FLOOR JOIST SCHEDULE JOIST MARK JOIST SIZE SPACING (UNO) FJ1 9 1/2" RED I 45 16"OC FJ4 DBL 1 3/4"x5 1/2" LVL 16"OC 1.SEE THIRD FLOOR FRAMING PLAN FOR FRAMING SYMBOL LEGEND AND NOTES AS APPLICABLE. 2.SEE GENERAL NOTES SHEET S1.0 FOR APPLICABLE NOTES REGARDING THE VARIOUS CONSTRUCTION ELEMENTS SHOWN ON PLAN. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3.FINISH ROOF ELEVATION = PER ARCH. 4.UNLESS NOTED OTHERWISE, ROOF SHEATHING SHALL BE 5/8" STRUCT I PLYWOOD, BLOCKED, W/ 10d NAILS @ 6",6",12" (BN,EN,FN). 5.ALL FLOOR MEMBERS NOT OTHERWISE DIMENSIONED SHALL BE EQUALLY SPACED BETWEEN GIRDERS OR OTHER SUPPORTS. 6.FOR FRAMING SPANS GREATER THAN 6'-0", PROVIDE WOOD BLOCKING AT THE LESSER OF MIDSPAN OR 8'-0"OC. INSTALL BLOCKING PER APPLICABLE TYPICAL DETAILS. 7.SEE ARCHITECTURAL PLANS FOR ROOF DEPRESSIONS AND SLOPES. 8.UNLESS NOTED OTHERWISE, MAXIMUM OPERATING WEIGHT ROOF TOP MECHANICAL UNITS SHALL BE 250#. PROVIDE DOUBLE JOIST SUPPORT FOR MECHANICAL UNITS EXCEEDING 250# OPERATING WEIGHT. SEE A/S9.1 FOR EQUIPMENT ANCHORAGE SCHEDULE. SEE MECHANICAL DRAWINGS FOR PRECISE SIZE AND LOCATIONS OF MECHANICAL UNITS. 9.SEE ARCHITECTURAL, MECHANICAL, AND/OR ELECTRICAL DRAWINGS FOR LOCATION OF ALL EQUIPMENT. 10.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED WITH ACTUAL EQUIPMENT TO BE INSTALLED. 11.CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF ALL ACCESS PANEL & EQUIPMENT ANCHOR/ MOUNTING HOLES PRIOR TO INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS PROVIDED ON PLANS AND/OR DETAILS, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. SEE 12/S6.1 & 13/S6.1 FOR FRAMING OPENING DETAILS. 12.SEE SHEET S6.5 FOR TYPICAL DRAG STRAP CONNECTIONS. 13.SEE 12 /S9.1 FOR ROOF TOP MECH SCREEN CONNECTION DETAILS ROOF FRAMING PLAN NOTES ROOF BEAM SCHEDULE BEAM MARK JOIST SIZE RB1 5 1/4"x9 1/2" LVL RB4 6x6 ROOF JOIST SCHEDULE JOIST MARK JOIST SIZE SPACING (UNO) RJ3 1 3/4x5 1/2 LVL 24"OC RJ4 9 1/2" RED I-45 24"OC POST SCHEDULE POST MARK POST SIZE P1 6x6 P2 6x4 P3 4x4 P4 4x6 P5 4x8 P6 4x10 P7 6x10 P8 (2)-2x8 P9 (3)-2x8 P10 (4)-2x8 P11 6x8 P12 8x8 STEEL COLUMN SCHEDULE COLUMN MARK COLUMN SIZE REFERENCE DETAIL NOTE C1 HSS5x5x1/4 9/S4.1 OR 2/S6.2, UNO 3/4" THK BASE PL C2 HSS8x6x1/4 STUB COL SEE PLAN COORDINATE LOCATION WITH ELEVATOR C3 HSS5x5x1/4 9/S4.1 1" , TYPE B BASE PL C4 HSS5x5x1/4 9/S4.1 1" , TYPE C BASE PL C5 HSS4x4x1/4 9/S4.1 1" , TYPE C BASE PL C6 HSS5x5x5/16 9/S4.1 1" , TYPE A BASE PL C7 HSS6x4x1/2 FLOOR WOOD BEAM SCHEDULE BEAM MARK BEAM SIZE COMMENTS B1 5 1/4"x9 1/2" LVL TYP, UNO B7 3 1/2"x9 1/2" LVL HANGER NOTE: AT STEEL AND CMU, PROVIDE SIMPSON "W" HANGER EACH END UNLESS NOTED OTHERWISE AT CMU PROVIDE (4)-7/8"Ø AB @ 8"OC EACH SIDE OF BEAM WHERE LEDGER OCCURS. STEEL BEAM SCHEDULE BEAM MARK JOIST SIZE SB1 W8x21 SB2 W8x15 SB3 W8x35 SB4 HSS6x6x1/4 04.02.24 RFI 161 06. .24 RFI 207 RJ 3 TIEBACK LOCATIONS TO BE ATTACHMENT TOSTRUCTURE PER 15/S9.1 AT RJ4 AND SAWN LUMBERJOIST LOCATIONS, AND 14/S9.1 AT RJ3 JOIST LOCATIONS 18 3 1 / 2 " x 5 1 / 4 " L V L 3 1 / 2 " x 5 1 / 4 " L V L WOOD 06/18/2024 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT Exp. 6-30-25 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 1.2 RJ 1 LOW ROOF KEY PLAN 15 S6.4 SIM 3 S5.1 TYP3 S5.1 TYP RJ3 ABOVE SHTG PER NOTE #4 & 7 S6.1 ,TYP W8 x 1 5 W8 x 1 5 BE A M HO I S T BE A M HO I S T 15 S6.4 15 S6.4 TYP 15 S6.4 SIM RJ3 HSS5x5x1/4, TYP (3 LOCS) 30 " C L R FR O N T 42 " C L R FR O N T 42 " C L R 42"CLR 30"CLR FRONT 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R FR O N T 42 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 30" C L R 42"CLR 30"CLR FRONT DA DG DH DJ DK DL DM DP D7 D8.1 D12 D8.1 D12 DF DG.5 DH.5 DI.5 DK.5 DL.5 DC D8 D10 D11 DB DD DN DE D10 D11 D11.9 SHTG PER NOTE #4 & 7 S6.1 ,TYP 9 S6.4 6 S6.4 8 S6.4 9 S6.4 6x 1 0 H D R , T Y P U N O RJ 4 RJ3 RJ3 RB 1 DB L PROVIDE (2)-ROWS FLOOR SHTG BN ALONG THIS WALL 13 S6.4 TYP RB4 7"x9 1/2" LVL 7" x 9 1 / 2 " L V L 7" x 9 1 / 2 " L V L 7"x9 1/2" LVL RB1 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 RJ 4 SB2 RJ 4 RB 4 RB 4 RJ 4 RJ 4 RJ4 DBL RJ 3 RJ3 RB4 SB2 RJ 4 RB 1 RB1 RB 1 RB 1 RJ 4 RJ 4 SB 1 SB2 SB2 SB 1 RJ 4 RJ 4 B1 FJ4 2x 1 0 @ 1 2 " O C SB2 K S5.3 BELOW C S2.7 STAIR 2 ABOVE 5 S6.4 SB 4 HP 3-1 MAX OP WT=918#RB 1 RB 1 RB 1 RB1RB1 RB1 RB 1 RB 1 RB 1 RB 1 RB 1 HP 4-1 MAX OP WT=918# HP 5-1 MAX OP WT=918# HP 6-1 MAX OP WT=918#HP 114B MAX OP WT=519# HP 114A MAX OP WT=519# RB 1 RB 1 RB 1 RB 1 RB 1 RB 1 RB 1 RB 1 RB1 RB1 RB1 RB1 RB1 RB1 RB 1 RB 1 RB 1 RB 1 GWH PER PLUMBING, MAX OP WT= 1,600# EA HP 115A MAX OP WT=519# RB 1 RB 1 RB 1 RB 1 RB 1 RB 1 RB1 RB1 RB1 RB1 6 S6.4SIM 6x 1 0 6x10 6x 1 0 RJ3 RJ4 24" MST BENT STRAP, TYP SB4 FLOOR OPNG PER 12 S6.1 & 13 S6.1 AS APPLICABLE, TYP 12 S9.1 TYP AT SCREENWALL 2X 1 0 @ 1 2 " O C 24" MST BENT STRAP, TYP 5 S6.4 9 S6.4 B S2.7 ROOF ABOVE 4 S6.4 3 S6.4 6x 1 0 H D R , T Y P U N O 6x10 HDR 6x 1 0 4x10 4x10 8 S6.4 11 S6.4 4 S6.4 3 S6.4 10 S6.4 DB L 2 x 1 0 DB L 9 1 / 2 " RE D I - 4 5 4x10 2x10 @ 12"0C 2x10 @ 12"0C DB L 9 1 / 2 " RE D I - 4 5 HP 701 MAX OP WT=153# RB 1 RB 1 HP 115B MAX OP WT=519# PROVIDE DBL JOISTS BENEATH WATER HEATERS RB 1 RB 1 RB1 RB1 RB1 RJ 4 RJ 4 SF 7-2 MAX OP WT=99# 3 S9.1TYP HP 117 MAX OP WT=393# 2x10 @ 12"0C SF 7-1 MAX OP WT=389# RB4 RB4 RB4 RB4 EF 7-5 MAX OP WT=247# HP IT MAX OP WT=657# RB4 D8.1D8 D10 DC DB DD D8.1 D10 RJ 3 15 S6.4 15 S6.4 SIM DM DP DN H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 1 H i l t o n A r c a d i a H o t e l ( N e w D e s i g n ) \ 3 _ D r a w i n g s \ D w g s - 0 1 \ 1 9 - 0 2 8 3 - 0 1 _ B l d g D _ S 2 . 7 ( R O O F & H I G H E L E V A T O R F R A M I N G P L A N S ) . d w g P L O T T E D B Y : Ch a n n o n S h i d a k i O N : Ju n e 2 7 , 2 0 2 4 A T : 9: 4 6 A M SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME S2.7 ROOF & HIGH ELEVATOR FRAMING PLANS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 125 W HUNTINGTON DR. BUILDING C & D ARCADIA, CA 91007 VG PROPERTIES INVESTMENTS, LLC NO.DATE ISSUES & REVISIONS S 3900 Cover Street Long Beach, CA 90808 562.985.3200 P TRUC T URAL E N GI N SREE MHP JN 562.985.1011 F 19-0283-01 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) SCALE:S2.7 ROOF & HIGH ELEVATOR FRAMING PLANS A 1/8" = 1'-0" ROOF JOIST SCHEDULE JOIST MARK JOIST SIZE SPACING (UNO) RJ3 1 3/4x5 1/2 LVL 24"OC RJ4 9 1/2" RED I-45 24"OC 1.SEE THIRD FLOOR FRAMING PLAN FOR FRAMING SYMBOL LEGEND AND NOTES AS APPLICABLE. 2.SEE GENERAL NOTES SHEET S1.0 FOR APPLICABLE NOTES REGARDING THE VARIOUS CONSTRUCTION ELEMENTS SHOWN ON PLAN. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3.FINISH ROOF ELEVATION = PER ARCH. 4.UNLESS NOTED OTHERWISE, ROOF SHEATHING SHALL BE 5/8" STRUCT I PLYWOOD, BLOCKED, W/ 10d NAILS @ 6",6",12" (BN,EN,FN). 5.ALL FLOOR MEMBERS NOT OTHERWISE DIMENSIONED SHALL BE EQUALLY SPACED BETWEEN GIRDERS OR OTHER SUPPORTS. 6.FOR FRAMING SPANS GREATER THAN 6'-0", PROVIDE WOOD BLOCKING AT THE LESSER OF MIDSPAN OR 8'-0"OC. INSTALL BLOCKING PER APPLICABLE TYPICAL DETAILS. 7.SEE ARCHITECTURAL PLANS FOR ROOF DEPRESSIONS AND SLOPES. 8.UNLESS NOTED OTHERWISE, MAXIMUM OPERATING WEIGHT ROOF TOP MECHANICAL UNITS SHALL BE 250#. PROVIDE DOUBLE JOIST SUPPORT FOR MECHANICAL UNITS EXCEEDING 250# OPERATING WEIGHT. SEE A/S9.1 FOR EQUIPMENT ANCHORAGE SCHEDULE. SEE MECHANICAL DRAWINGS FOR PRECISE SIZE AND LOCATIONS OF MECHANICAL UNITS. 9.SEE ARCHITECTURAL, MECHANICAL, AND/OR ELECTRICAL DRAWINGS FOR LOCATION OF ALL EQUIPMENT. 10.DIMENSIONS OF EQUIPMENT ANCHOR/ MOUNTING LOCATIONS SHOWN ON PLANS AND/OR DETAILS ARE TO BE COORDINATED WITH ACTUAL EQUIPMENT TO BE INSTALLED. 11.CONTRACTOR TO VERIFY THE EXACT SIZE AND LOCATION OF ALL ACCESS PANEL & EQUIPMENT ANCHOR/ MOUNTING HOLES PRIOR TO INSTALLATION. WHERE ACTUAL EQUIPMENT DIMENSIONS DO NOT FALL WITHIN THE MINIMUM OR MAXIMUM DIMENSIONS PROVIDED ON PLANS AND/OR DETAILS, NOTIFY SEOR AND AWAIT DIRECTION PRIOR TO PROCEEDING WITH WORK. SEE 12/S6.1 & 13/S6.1 FOR FRAMING OPENING DETAILS. 12.SEE SHEET S6.5 FOR TYPICAL DRAG STRAP CONNECTIONS. 13.SEE 12 /S9.1 FOR ROOF TOP MECH SCREEN CONNECTION DETAILS ROOF FRAMING PLAN NOTES ROOF BEAM SCHEDULE BEAM MARK JOIST SIZE RB1 5 1/4"x9 1/2" LVL RB4 6x6 SCALE:S2.7 ELEVATOR PENTHOUSE FRAMING PLAN B 1/8" = 1'-0" STEEL COLUMN SCHEDULE COLUMN MARK COLUMN SIZE REFERENCE DETAIL NOTE C1 HSS5x5x1/4 9/S4.1 OR 2/S6.2, UNO 3/4" THK BASE PL C2 HSS8x6x1/4 STUB COL SEE PLAN COORDINATE LOCATION WITH ELEVATOR C3 HSS5x5x1/4 9/S4.1 1" , TYPE B BASE PL C4 HSS5x5x1/4 9/S4.1 1" , TYPE C BASE PL C5 HSS4x4x1/4 9/S4.1 1" , TYPE C BASE PL C6 HSS5x5x5/16 9/S4.1 1" , TYPE A BASE PL C7 HSS6x4x1/2 LIST OF APPLICABLE TYPICAL FRAMING DETAILS DESCRIPTION DETAIL SHEET TYPICAL BEAM CONNECTION SCHEDULE 1 S5.1 TYPICAL BEAM TO BEAM CONNECTION 2 S5.1 TYPICAL BEAM TO COLUMN CONNECTION 3 S5.1 TYPICAL STIFFENER PLATE 4 S5.1 TI FRAMING AT STEEL BEAM 5 S5.1 WOOD BEAM TO STEEL COLUMN 7 S5.1 TYPICAL BEAM TO BEAM MOMENT CONNECTION 8 S5.1 TYPICAL WOOD BEAM TO WOOD BEAM CONNECTION 1 S6.1 TYPICAL JOIST TO WOOD BEAM CONNECTION 2 S6.1 WOOD POST BASE TO CONCRETE 3 S6.1 TYPICAL OPENING IN EXTERIOR WOOD STUD WALL 4 S6.1 TYPICAL OPENING IN INTERIOR WOOD STUD WALL 5 S6.1 WOOD STUD WALL TO CONCRETE 6 S6.1 TYPICAL HORIZONTAL PLYWOOD SHEATHING 7 S6.1 WOOD POST TO BEAM CONNECTION WITHIN WALL 8 S6.1 TYPICAL WOOD NAILER AT STEEL BEAM 9 S6.1 DOUBLE TOP PLATE SPLICE SCHEDULE 10 S6.1 TYPICAL WOOD BEAM HANGER SCHEDULE 11 S6.1 TYPICAL HORIZONTAL FRAMING AT OPENING BETWEEN JOIST OR RAFTER (2'-0" MAX)12 S6.1 TYPICAL HORIZONTAL FRAMING AT OPENING (4'-0" MAX)13 S6.1 TYPICAL WOOD BEAM TO ISOLATED WOOD POST 14 S6.1 NON-BEARING PARTITION 15 S6.1 TYPICAL WOOD STUD WALL BLOCKING / BACKING 16 S6.1 TYPICAL DOUBLE PLYWOOD WEB JOIST 17 S6.1 TYPICAL HOLES AND NOTCHES IN WOOD 18 S6.1 HOLE IN BEAMS 19 S6.1 TYPICAL BEAM IN WALL 20 S6.1 TYPICAL MULTI-STORY SHEAR WALL ELEVATION, SCHEDULE AND NOTES A S6.2 DETAIL 1 S6.2 HSS OR PIPE COLUMN IN SHEAR WALL 2 S6.2 HOLDOWN AT UPPER FLOORS 3 S6.2 TYPICAL CORNERS AND INTERSECTIONS AT WOOD STUD SHEAR WALLS 4 S6.2 TYPICAL ATS ELEVATION VIEW AND ALLOWABLE PENETRATION AT SHEAR WALL 5 S6.2 TYPICAL STRINGER TO FRAMING CONNECTION 13 S6.3 FRAMING STRAP OVER TOP OF PLYWOOD 15 S6.3 TYPICAL I-JOIST WEB STIFFENER 17 S6.3 STEEL BEAM SCHEDULE BEAM MARK JOIST SIZE SB1 W8x21 SB2 W8x15 SB3 W8x35 SB4 HSS6x6x1/4 SCALE:S2.7 STAIR 2 - PENTHOUSE FRAMING PLAN C 1/8" = 1'-0" 04.02.24 RFI 161 07.01.24 RFI 216 Exp. 6-30-25 S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N AINRFOILA A ONS L E N G I KEN N E T H D.O'DE L L U R A LTSRUCT 07/01/2024 DB L 4x10 PROVIDE SIMP HWP HANGER WHERE INDICATED 2X10 @ 12" OC, TYP, 4X10 @ 12" 0C AT EBM FULCRUMLOCATIONS (4 MIN), PROVIDE SIMP HWP HANGER AT4x10 JOSTS ATTACHED TO Wx PROVIDE SIMP LGU5.25-SDS AT DBL JOIST END TIEBACK LOCATIONS TO BE ATTACHMENT TO STRUCTURE PER 15/S9.1 AT RJ4 AND SAWN LUMBER JOIST LOCATIONS, AND 14/S9.1 AT RJ3 JOIST LOCATIONS WOOD PLACE A DBL JOIST 1 FOOT AWAY FROM EXTERIOR WALL(IN ADDITION TO TYP ROOF JOISTS), TYP NEXT TO WALL ALONG GL D12 AS SHOWN (9 LOCS) WOOD DB L DB L DB L DB L DB L DB L DB L DB L WOOD TYP, 4X10 @ 12" 0C AT EBMFULCRUM LOCATIONS (4 MIN), ATTACH TODBL WITH SIMP LGU3.63-SDS. TYP AT JOISTSBELOW GL DL, UNO TIEBACK LOCATIONS TO BE ATTACHMENT TO STRUCTURE PER 15/S9.1 AT RJ4 AND SAWN LUMBER JOIST LOCATIONS, AND 14/S9.1 AT RJ3 JOIST LOCATIONS 1.3 RJ - 2 RJ - 4 RJ - 7 RJ - 9 RJ - 3 RJ - 5 RJ - 6 RJ-8 HIGH ROOF KEY PLAN CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.1 HILTON ARCADIA HOTEL EBM CALCULATIONS 8/28/24 FRAMING JOISTS NOTE Please note - during the submittal process, material substitutions were made for the joists as shown below. BOISE CASCADE RIVERSIDE PROJECT TRANSMITTAL LETTER Project: Hilton Arcadia 123 W Huntington Dr., Arcadia, CA 91007 Date: Oct 19th, 2023 Architectural Plan: Oct 3rd, 2023 (A2.14) Structural Plan: Oct 3rd, 2023 (S2.4) Buildings or Sections (BCE Lists): BUILDING D Site Plan Page: A-1.01 Levels: 3rd Floor (Stair), 4th Floor, 5th Floor, 6th Floor, Roof and High Roof 1. Material Substitutions (Framing to match On-Center Spacing & Direction as Drawn) Boise Cascade Product Plan Specified Product 9-1/2” BCI 1.8 DF @ 16”, 24” O.C for 9-1/2” RED I-45 @ 16”, 24” O.C DBL 1-3/4” x 5-1/2” VERSA-LAM 2.1E 2800 DF @ 16” O.C 1-3/4” x 5-1/2” VERSA-LAM 2.1E 2800 DF @ 24” O.C for DBL 1-3/4” x 5-1/2” LVL @ 16” O.C 1-3/4” x 5-1/2” LVL @ 24” O.C 3-1/2” x VERSA-LAM 2.1E 3100 DF 5-1/4” x VERSA-LAM 2.1E 3100 DF 7” x VERSA-LAM 2.1E 3100 DF for 3-1/2” x LVL 5-1/4” x LVL 7” x LVL 6500 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.2 Roof Dead Load = 18psf x (2'/2 + 0.75'/2) = 24.75plf Roof Live Load = 20psf x (2'/2 + 0.75'/2) = 27.5plf Tieback Load (Loads are not be considered concurrently): Lateral Load = 5000# x 2ft / 0.75' / 2 Anchors = 6667# (LRFD) = 4167# (ASD) Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH RJ-1 D+Lr 9" 4167#4167# 2.375' 3.125' 6' - 9" Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-1 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Boise Cascade Versa Lam 2800 2,800.0 2,800.0 3,000.0 750.0 2,000.0 1,036.83 285.0 2,100.0 41.760 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.02475 , Tributary Width = 1.0 ft, (Roof Load) Point Load : L = 4.167 k @ 3.125 ft, (Tieback Load) Point Load : L = -4.167 k @ 2.375 ft, (Tieback Load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.179: 1 Load Combination +D+0.750L Span # where maximum occurs Span # 1 Location of maximum on span 3.129ft 228.77 psi= = 5,824.00psi 3.50 X 5.250Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+0.750L= = = 570.00 psi== Section used for this span 3.50 X 5.250 Maximum Shear Stress Ratio 0.401 : 1 2.390ft= = 1,043.20psi Maximum Deflection 0 <360 1022Ratio =0 <180 Max Downward Transient Deflection 0.066 in 1228Ratio =>=360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.079 in Ratio =>=180 Max Upward Total Deflection 0 in fb: Actual Fb: Allowable fv: Actual Fv: Allowable Span: 1 : L Only n/a Span: 1 : +D+L n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length D Only 0.00 0.00 0.000.00 1.00Length = 6.725 ft 1 0.040 0.023 0.90 1.000 1.04 1.00 1.00 0.14 105.21 2620.80 0.07 256.501.00 5.97 1.00Length = 0.02464 ft 1 0.001 0.023 0.90 1.000 1.04 1.00 1.00 0.00 1.53 2620.80 0.07 256.501.00 5.97 1.00+D+0.750L 1.000 1.04 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 6.725 ft 1 0.179 0.401 2.00 1.000 1.04 1.00 1.00 1.40 1,043.20 5824.00 2.80 570.001.00 228.77 1.00Length = 0.02464 ft 1 0.001 0.401 2.00 1.000 1.04 1.00 1.00 0.01 7.91 5824.00 0.42 570.001.00 228.77 1.00+0.60D 1.000 1.04 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 6.725 ft 1 0.014 0.008 1.60 1.000 1.04 1.00 1.00 0.08 63.12 4659.20 0.04 456.001.00 3.58 1.00Length = 0.02464 ft 1 0.000 0.008 1.60 1.000 1.04 1.00 1.00 0.00 0.92 4659.20 0.04 456.001.00 3.58 . 2.1.3 Cd for live load cases was changed to 2.0 as the tieback impact load is defined as Live in Enercalc CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.4 Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH Roof Dead Load = 18psf x (2') = 36plf Roof Live Load = 20psf x (2') = 40plf Tieback Load (Loads are not be considered concurrently): Vertical Load = 2700#/4 Anchors = 675# Lateral Load = 5000# x 2ft / 11.25"/12 / 2 Anchors= 5333# (LRFD) = 3333# (ASD) RJ-2 D+Lr 11.25" 3333#3333 4.125' 4.875' 14' - 1" Shear Capacity = 1575#(Cd)(2 Members) = 1575#(2)(2) = 6300# > 3220# Moment Capacity = 7010#-ft(Cd) = 7010#-ft(2) = 14020#-ft > 3010#-ft Shear Demand = 3220# (See Enercalc Analysis next page) Moment Demand = 3010#-ft (See Enercalc Analysis next page) Each Member OK OK General Beam Analysis LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-2 Analysis Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: General Beam Properties Elastic Modulus ksi1,800.0 233.330Span #1 in^4Area =in^2 Moment of Inertia =Span Length =10.014.083 ft .Service loads entered. Load Factors will be applied for calculations.Applied Loads Uniform Load : D = 0.0360, Lr = 0.040 k/ft, Tributary Width = 1.0 ft, (Roof Load) Point Load : L = 3.333 k @ 4.0 ft, (Tieback Load) Point Load : L = -3.333 k @ 4.938 ft, (Tieback Load) .DESIGN SUMMARY Maximum Bending = Load Combination +D+0.750Lr+0.750L Span # where maximum occurs Span # 1 Location of maximum on span 3.943 ft 3.035 k Span # where maximum occurs Location of maximum on span Span # 1 Load Combination +D+L Maximum Shear = 4.929 ft 1.976 k-ft Maximum DeflectionMax Downward Transient Deflection 0.085 in 1989Max Upward Transient Deflection -0.096 in 1768Max Downward Total Deflection 0.161 in 1046Max Upward Total Deflection -0.019 in 8717 .Maximum Forces & Stresses for Load Combinations Span # Summary of Moment Values (k-ft)Load Combination Shear Values (k)Max Stress Ratios M V Mmax -Mmax +Rm VnxMa - Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length Overall MAXimum Envelope Dsgn. L = 14.08 ft 1 1.98 1.98 3.04 D Only Dsgn. L = 14.08 ft 1 0.89 0.89 0.25 +D+L Dsgn. L = 14.08 ft 1 1.59 -1.20 1.59 3.04 +D+Lr Dsgn. L = 14.08 ft 1 1.88 1.88 0.54 +D+0.750Lr+0.750L Dsgn. L = 14.08 ft 1 1.98 -0.01 1.98 2.19 +D+0.750L Dsgn. L = 14.08 ft 1 1.38 -0.69 1.38 2.26 +0.60D Dsgn. L = 14.08 ft 1 0.54 0.54 0.15 2.1.5 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.6 Roof Dead Load = 18psf x (2') = 36plf Roof Live Load = 20psf x (2') = 40plf Tieback Load Vertical Load = 2700#/4 Anchors = 675# Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH RJ-3 D+Lr 9" 675#675# 3.46' 4.21' 13' - 3" 13-03-00 B1 B2 1 2 3 Total Horizontal Product Length = 13-10-00 Page 1 of 2 Double 9-1/2"BCI®6500-1.8 DF RJ3 (Joist) BC CALC®Member Report Dry |1 span |No cant.|24"OCS |Non-Repetitive |Glued &nailed August 12,2024 20:43:21 Build 8892 Job name:Hilton Arcadia File name: Address:Description: City,State,Zip:Specifier: Customer:MHP Designer: Code reports:ESR-1336 Company: Page 1 of 2 Reaction Summary (Down /Uplift)(lbs)Bearing Live Dead Snow Wind Roof Live B1,3-1/2"0 /986 249 /0 277 /0 B2,3-1/2"0 /364 249 /0 277 /0 Load Summary Live Dead Snow Wind Roof Live OCS Tag Description Load Type Ref.Start End Loc.100%90%115%160%125% 1 Unf.Area (lb/ft²)L 00-00-00 13-10-00 Top 36 40 12" 2 Conc.Pt.(lbs)L 03-05-08 03-05-08 Top -675 n\a 3 Conc.Pt.(lbs)L 04-02-08 04-02-08 Top -675 n\a Controls Summary Value %Allowable Duration Case Location Pos.Moment 1699 ft-lbs 19.4%125%2 06-10-09 Neg.Moment -2745 ft-lbs 39.2%100%1 04-02-08 End Reaction 526 lbs 15.3%125%2 00-00-00 End Shear 748 lbs 23.7%100%1 00-03-08 Total Load Deflection L/1255 (0.128")19.1%n\a 2 06-10-09 Live Load Deflection L/796 (-0.202")60.3%n\a 5 05-09-12 Total Neg.Defl.L/1118 (-0.144")21.5%n\a 1 05-04-15 Max Defl.-0.144"14.4%n\a 1 05-04-15 Span /Depth 16.9 Bearing Supports Dim.(LxW)Value %Allow Support %Allow Member Material B1 Wall/Plate 3-1/2"x 5-1/8"526 lbs n\a 15.3%Unspecified B1 Uplift 737 lbs B2 Wall/Plate 3-1/2"x 5-1/8"526 lbs n\a 15.3%Unspecified B2 Uplift 115 lbs BC FloorValue®Summary BC FloorValue®:Subfloor:3/4"OSB,Glue +Nail Minimum Enhanced Premium Subfloor Rating:Code Minimum Controlling Location:06-11-00 Cautions Uplift of -737 lbs found at bearing B1. All multiple member 9-1/2"BCI®6500-1.8 DF applications with side load or unevenly distributed top load require filler blocks and fasteners.See Boise Cascade Technical Note IJ-13 for further information. 2.1.7 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.8 Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH Roof Dead Load = 18psf x (1') = 18plf Roof Live Load = 20psf x (1') = 20plf Bearing Plate Load: P = 6700#/2legs/= 3350# w = 3350#/(1.5ftx1.5ft) x 1'(Trib Width) = 1490plf RJ-4 D+Lr 1490plf1490plf 1.5' 13' - 3" 5.75' Shear Capacity = 1575#(Cd)(2 Members) =1575#(1.6)(2) = 5040# > 4217# Moment Capacity = 7010#-ft(Cd) = 7010#-ft(1.6) = 11216#-ft > 8873#-ft Shear Demand = 3113# (See Enercalc Analysis next page) Moment Demand = 8.873#-ft (See Enercalc Analysis next page) Each Member Cd of 1.6 was conservatively used for the ultimate bearing load OK OK General Beam Analysis LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-4 Analysis Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: General Beam Properties Elastic Modulus ksi1,800.0 233.330Span #1 in^4Area =in^2 Moment of Inertia =Span Length =10.013.250 ft .Service loads entered. Load Factors will be applied for calculations.Applied Loads Uniform Load : D = 0.0180, Lr = 0.020 k/ft, Tributary Width = 1.0 ft, (Roof Load) Uniform Load : L = 1.490 k/ft, Extent = 0.750 -->> 2.250 ft, Tributary Width = 1.0 ft, (Bearing Load) Uniform Load : L = 1.490 k/ft, Extent = 6.50 -->> 8.0 ft, Tributary Width = 1.0 ft, (Bearing Load) .DESIGN SUMMARY Maximum Bending = Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 7.023 ft 3.113 k Span # where maximum occurs Location of maximum on span Span # 1 Load Combination +D+L Maximum Shear = 0.000 ft 8.873 k-ft Maximum DeflectionMax Downward Transient Deflection 0.590 in 269Max Upward Transient Deflection 0.000 in 0Max Downward Total Deflection 0.620 in 256Max Upward Total Deflection 0.000 in 557250 .Maximum Forces & Stresses for Load Combinations Span # Summary of Moment Values (k-ft)Load Combination Shear Values (k)Max Stress Ratios M V Mmax -Mmax +Rm VnxMa - Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length Overall MAXimum Envelope Dsgn. L = 13.25 ft 1 8.87 8.87 3.11 D Only Dsgn. L = 13.25 ft 1 0.40 0.40 0.12 +D+L Dsgn. L = 13.25 ft 1 8.87 8.87 3.11 +D+Lr Dsgn. L = 13.25 ft 1 0.83 0.83 0.25 +D+0.750Lr+0.750L Dsgn. L = 13.25 ft 1 7.08 7.08 2.46 +D+0.750L Dsgn. L = 13.25 ft 1 6.75 6.75 2.36 +0.60D Dsgn. L = 13.25 ft 1 0.24 0.24 0.07 2.1.9 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.10 Roof Dead Load = 18psf x (0.5') = 9plf Roof Live Load = 20psf x (0.5') = 10plf Tieback Load: Vertical Load = 2700#/4 Anchors/2members = 337.5# Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH RJ-5 D+Lr 9" 337.5#337.5# 3.88' 4.63' 10' - 7" Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-5 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2018 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Uniform Load : D = 0.0090, Lr = 0.010 ksf, Tributary Width = 0.50 ft, (Roof Loads) Point Load : L = -0.3375 k @ 3.880 ft, (Tieback Load) Point Load : L = -0.3375 k @ 4.630 ft, (Tieback Load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.880: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 4.635ft 42.94 psi= = 990.00psi 2x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L = = = 180.00 psi== Section used for this span 2x10 Maximum Shear Stress Ratio 0.239 : 1 3.863ft== 870.79psi Maximum Deflection 735 >=360 7453Ratio =770 >=180 Max Downward Transient Deflection 0.009 in 14160Ratio =>=360 Max Upward Transient Deflection -0.173 in Ratio = Max Downward Total Deflection 0.017 in Ratio =>=180 Max Upward Total Deflection -0.165 in fb: Actual Fb: Allowable fv: Actual Fv: Allowable Span: 1 : Lr Only Span: 1 : L Only Span: 1 : +D+Lr Span: 1 : +D+L .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length D Only 0.00 0.00 0.000.001.00Length = 10.583 ft 1 0.040 0.014 0.90 1.100 1.00 1.00 1.00 0.06 35.34 891.00 0.02 162.001.00 2.22 1.00+D+L 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 10.583 ft 1 0.880 0.239 1.00 1.100 1.00 1.00 1.00 1.55 870.79 990.00 0.40 180.001.00 42.941.00+D+Lr 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 10.583 ft 1 0.060 0.021 1.25 1.100 1.00 1.00 1.00 0.13 74.62 1237.50 0.04 225.001.00 4.68 1.00+D+0.750Lr+0.750L 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 10.583 ft 1 0.497 0.140 1.25 1.100 1.00 1.00 1.00 1.10 615.39 1237.50 0.29 225.001.00 31.451.00+D+0.750L 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 10.583 ft 1 0.566 0.155 1.15 1.100 1.00 1.00 1.00 1.15 644.39 1138.50 0.30 207.001.00 32.03 1.00+0.60D 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 2.1.11 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.12 Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH Roof Dead Load = 18psf x (0.5') = 9plf Roof Live Load = 20psf x (0.5') = 10plf Tieback Load (Loads are not be considered concurrently): Vertical Load = 2700#/4 Anchors/2members = 337.5# Wind Load = 28psf RJ-6 D+Lr 337.5#337.5# 1.375' 8' - 6" 9" 4' - 5" 2.125 28psf wind each direction Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-6 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : IBC 2018 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :IBC 2018 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0090, Lr = 0.010 k/ft Load for Span Number 1 Point Load : L = -0.3380 k @ 1.375 ft Point Load : L = -0.3380 k @ 2.125 ft Load for Span Number 2 Uniform Load : W = 0.0280 ksf, Tributary Width = 1.0 ft, (Wind) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.478: 1 Load Combination +D+L Span # where maximum occurs Span # 1 Location of maximum on span 2.137ft 56.19 psi= = 990.00psi 2x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+L= = = 180.00 psi== Section used for this span 2x10 Maximum Shear Stress Ratio 0.312 : 1 1.330ft= = 473.52psi Maximum Deflection 1815 >=360 1252Ratio =1915 >=180 Max Downward Transient Deflection 0.073 in 1378Ratio =>=360 Max Upward Transient Deflection -0.056 in Ratio = Max Downward Total Deflection 0.080 in Ratio =>=180 Max Upward Total Deflection -0.053 in fb: Actual Fb: Allowable fv: Actual Fv: Allowable Span: 2 : L Only Span: 1 : L Only Span: 2 : +D+0.750Lr+0.750L+0.450W Span: 2 : +D+Lr .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length D Only 0.00 0.00 0.000.00 1.00Length = 8.50 ft 1 0.049 0.027 0.90 1.100 1.00 1.00 1.00 0.08 43.90 891.00 0.04 162.001.00 4.39 1.00Length = 4.170 ft 2 0.049 0.027 0.90 1.100 1.00 1.00 1.00 0.08 43.90 891.00 0.03 162.001.00 4.39 1.00+D+L 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 8.50 ft 1 0.478 0.312 1.00 1.100 1.00 1.00 1.00 0.84 473.52 990.00 0.52 180.001.00 56.19 1.00Length = 4.170 ft 2 0.044 0.312 1.00 1.100 1.00 1.00 1.00 0.08 43.90 990.00 0.03 180.001.00 56.19 1.00+D+Lr 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 2.1.13 Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-6 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length 1.00Length = 8.50 ft 1 0.075 0.041 1.25 1.100 1.00 1.00 1.00 0.17 92.67 1237.50 0.09 225.001.00 9.27 1.00Length = 4.170 ft 2 0.075 0.041 1.25 1.100 1.00 1.00 1.00 0.17 92.67 1237.50 0.06 225.001.00 9.27 1.00+D+0.750Lr+0.750L 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.267 0.178 1.25 1.100 1.00 1.00 1.00 0.59 329.91 1237.50 0.37 225.001.00 40.141.00Length = 4.170 ft 2 0.065 0.178 1.25 1.100 1.00 1.00 1.00 0.14 80.48 1237.50 0.06 225.001.00 40.14 1.00+D+0.750L 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.307 0.201 1.15 1.100 1.00 1.00 1.00 0.62 349.32 1138.50 0.39 207.001.00 41.68 1.00Length = 4.170 ft 2 0.039 0.201 1.15 1.100 1.00 1.00 1.00 0.08 43.90 1138.50 0.03 207.001.00 41.68 1.00+D+0.60W 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.079 0.033 1.60 1.100 1.00 1.00 1.00 0.22 125.84 1584.00 0.09 288.001.00 9.49 1.00Length = 4.170 ft 2 0.079 0.033 1.60 1.100 1.00 1.00 1.00 0.22 125.84 1584.00 0.09 288.001.00 9.491.00+D-0.60W 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.042 0.015 1.60 1.100 1.00 1.00 1.00 0.12 66.60 1584.00 0.04 288.001.00 4.26 1.00Length = 4.170 ft 2 0.024 0.015 1.60 1.100 1.00 1.00 1.00 0.07 38.04 1584.00 0.03 288.001.00 4.26 1.00+D+0.750Lr+0.750L+0.450W 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 8.50 ft 1 0.218 0.144 1.60 1.100 1.00 1.00 1.00 0.62 345.36 1584.00 0.38 288.001.00 41.53 1.00Length = 4.170 ft 2 0.090 0.144 1.60 1.100 1.00 1.00 1.00 0.25 141.94 1584.00 0.10 288.001.00 41.53 1.00+D+0.750Lr+0.750L-0.450W 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 8.50 ft 1 0.199 0.135 1.60 1.100 1.00 1.00 1.00 0.56 314.46 1584.00 0.36 288.001.00 38.75 1.00Length = 4.170 ft 2 0.012 0.135 1.60 1.100 1.00 1.00 1.00 0.03 19.02 1584.00 0.01 288.001.00 38.75 1.00+D+0.750L+0.450W 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.230 0.150 1.60 1.100 1.00 1.00 1.00 0.65 364.77 1584.00 0.40 288.001.00 43.071.00Length = 4.170 ft 2 0.067 0.150 1.60 1.100 1.00 1.00 1.00 0.19 105.35 1584.00 0.07 288.001.00 43.07 1.00+D+0.750L-0.450W 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.211 0.140 1.60 1.100 1.00 1.00 1.00 0.60 333.87 1584.00 0.37 288.001.00 40.291.00Length = 4.170 ft 2 0.011 0.140 1.60 1.100 1.00 1.00 1.00 0.03 17.56 1584.00 0.01 288.001.00 40.29 1.00+0.60D+0.60W 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.068 0.028 1.60 1.100 1.00 1.00 1.00 0.19 108.28 1584.00 0.08 288.001.00 8.16 1.00Length = 4.170 ft 2 0.068 0.028 1.60 1.100 1.00 1.00 1.00 0.19 108.28 1584.00 0.08 288.001.00 8.161.00+0.60D-0.60W 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.039 0.015 1.60 1.100 1.00 1.00 1.00 0.11 62.22 1584.00 0.04 288.001.00 4.19 1.00Length = 4.170 ft 2 0.035 0.015 1.60 1.100 1.00 1.00 1.00 0.10 55.60 1584.00 0.04 288.001.00 4.191.00+0.60D 1.100 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.017 0.009 1.60 1.100 1.00 1.00 1.00 0.05 26.34 1584.00 0.02 288.001.00 2.63 1.00Length = 4.170 ft 2 0.017 0.009 1.60 1.100 1.00 1.00 1.00 0.05 26.34 1584.00 0.02 288.001.00 2.63 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections L Only10.0000 0.000 -0.0562 3.751 +D+0.750Lr+0.750L+0.450W 2 0.0798 4.170 0.0000 3.751 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum -0.537 0.179 Overall MINimum -0.029 0.145 D Only 0.029 0.085 +D+L -0.508 -0.054 +D+Lr 0.061 0.179 +D+0.750Lr+0.750L -0.349 0.051 +D+0.750L -0.374 -0.019 +D+0.60W 0.012 0.172 +D+0.750Lr+0.750L+0.450W -0.362 0.117 +D+0.750L+0.450W -0.386 0.046 +0.60D+0.60W 0.000 0.138 +0.60D 0.017 0.051 Lr Only 0.032 0.094 L Only -0.537 -0.139 W Only -0.029 0.145 2.1.14 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.15 Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH Roof Dead Load = 18psf x (1') = 18plf Roof Live Load = 20psf x (1') = 20plf Bearing Plate Load: P = 6700#/2legs/= 3350# w = 3350#/(1.5ftx1.5ft) x 1.0'(Trib Width) = 1490plf Wind Load = 28psf RJ-7 D+Lr 1490plf 1.5' 8' - 6"4' - 5" 28psf wind each direction Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-7 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0180, Lr = 0.020 k/ft Load for Span Number 2 Uniform Load : W = 0.0280 ksf, Tributary Width = 1.0 ft, (Wind) Uniform Load : L = 1.490 k/ft, Extent = 0.0 -->> 1.50 ft, Tributary Width = 1.0 ft, (Bearing Load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.230: 1 Load Combination +D+0.750Lr+0.750L+0.450W Span # where maximum occurs Span # 1 Location of maximum on span 8.500ft 45.05 psi= = 1,728.00psi 4x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+0.750Lr+0.750L+0.450W= = = 288.00 psi== Section used for this span 4x10 Maximum Shear Stress Ratio 0.156 : 1 8.500ft== 397.58psi Maximum Deflection 2785 >=360 906Ratio =2961 >=180 Max Downward Transient Deflection 0.107 in 930Ratio =>=360 Max Upward Transient Deflection -0.037 in Ratio = Max Downward Total Deflection 0.110 in Ratio =>=180 Max Upward Total Deflection -0.034 in fb: Actual Fb: Allowable fv: Actual Fv: Allowable Span: 2 : L Only Span: 1 : L Only Span: 2 : +D+L Span: 2 : +D+Lr .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length D Only 0.00 0.00 0.000.00 1.00Length = 8.50 ft 1 0.039 0.023 0.90 1.200 1.00 1.00 1.00 0.16 37.63 972.00 0.08 162.001.00 3.76 1.00Length = 4.170 ft 2 0.039 0.023 0.90 1.200 1.00 1.00 1.00 0.16 37.63 972.00 0.06 162.001.00 3.76 1.00+D+Lr 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 8.50 ft 1 0.059 0.035 1.25 1.200 1.00 1.00 1.00 0.33 79.43 1350.00 0.17 225.001.00 7.95 1.00Length = 4.170 ft 2 0.059 0.035 1.25 1.200 1.00 1.00 1.00 0.33 79.43 1350.00 0.13 225.001.00 7.95 1.00+D+0.750Lr+0.750L 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.215 0.150 1.60 1.200 1.00 1.00 1.00 1.54 371.24 1728.00 0.93 288.001.00 43.06 1.00Length = 4.170 ft 2 0.215 0.150 1.60 1.200 1.00 1.00 1.00 1.54 371.24 1728.00 0.93 288.001.00 43.06 2.1.16 Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-7 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length 1.00+D+0.750L 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.197 0.141 1.60 1.200 1.00 1.00 1.00 1.41 339.89 1728.00 0.88 288.001.00 40.70 1.00Length = 4.170 ft 2 0.197 0.141 1.60 1.200 1.00 1.00 1.00 1.41 339.89 1728.00 0.88 288.001.00 40.70 1.00+D+0.750Lr+0.750L+0.450W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 8.50 ft 1 0.230 0.156 1.60 1.200 1.00 1.00 1.00 1.65 397.58 1728.00 0.97 288.001.00 45.05 1.00Length = 4.170 ft 2 0.230 0.156 1.60 1.200 1.00 1.00 1.00 1.65 397.58 1728.00 0.97 288.001.00 45.05 1.00+D+0.750Lr+0.750L-0.450W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.200 0.143 1.60 1.200 1.00 1.00 1.00 1.43 344.90 1728.00 0.89 288.001.00 41.07 1.00Length = 4.170 ft 2 0.200 0.143 1.60 1.200 1.00 1.00 1.00 1.43 344.90 1728.00 0.89 288.001.00 41.07 1.00+D+0.750L+0.450W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.212 0.148 1.60 1.200 1.00 1.00 1.00 1.52 366.23 1728.00 0.92 288.001.00 42.681.00Length = 4.170 ft 2 0.212 0.148 1.60 1.200 1.00 1.00 1.00 1.52 366.23 1728.00 0.92 288.001.00 42.68 1.00+D+0.750L-0.450W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.181 0.134 1.60 1.200 1.00 1.00 1.00 1.30 313.55 1728.00 0.84 288.001.00 38.71 1.00Length = 4.170 ft 2 0.181 0.134 1.60 1.200 1.00 1.00 1.00 1.30 313.55 1728.00 0.84 288.001.00 38.711.00+0.60D+0.60W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.033 0.015 1.60 1.200 1.00 1.00 1.00 0.24 57.69 1728.00 0.09 288.001.00 4.35 1.00Length = 4.170 ft 2 0.033 0.015 1.60 1.200 1.00 1.00 1.00 0.24 57.69 1728.00 0.09 288.001.00 4.351.00+0.60D-0.60W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 8.50 ft 1 0.017 0.007 1.60 1.200 1.00 1.00 1.00 0.13 30.14 1728.00 0.04 288.001.00 2.03 1.00Length = 4.170 ft 2 0.007 0.007 1.60 1.200 1.00 1.00 1.00 0.05 12.54 1728.00 0.02 288.001.00 2.03 1.00+0.60D 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 8.50 ft 1 0.013 0.008 1.60 1.200 1.00 1.00 1.00 0.09 22.58 1728.00 0.05 288.001.00 2.26 1.00Length = 4.170 ft 2 0.013 0.008 1.60 1.200 1.00 1.00 1.00 0.09 22.58 1728.00 0.04 288.001.00 2.26 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections L Only10.0000 0.000 -0.0366 4.939 +D+L 2 0.1103 4.170 0.0000 4.939 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum -0.197 2.602 Overall MINimum -0.029 0.145 D Only 0.058 0.170 +D+L -0.139 2.602 +D+Lr 0.123 0.359 +D+0.750Lr+0.750L -0.041 2.136 +D+0.750L -0.090 1.994 +D+0.60W 0.041 0.257 +D+0.750Lr+0.750L+0.450W -0.054 2.201 +D+0.750L+0.450W -0.103 2.060 +0.60D+0.60W 0.018 0.189 +0.60D 0.035 0.102 Lr Only 0.065 0.189 L Only -0.197 2.432 W Only -0.029 0.145 2.1.17 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.18 Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH Roof Dead Load = 18psf x (1') = 18plf Roof Live Load = 20psf x (1') = 20plf Bearing Plate Load: P = 6700#/2legs/= 3350# w = 3350#/(1.5ftx1.5ft) x 1.0'(Trib Width) = 1490plf Wind Load = 28psf RJ-8 D+Lr 1490plf 1.5' 8' - 6" 4' - 3"28psf Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-8 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Loads on all spans... Uniform Load on ALL spans : D = 0.0180, Lr = 0.020 k/ft Load for Span Number 2 Uniform Load : W = 0.0280 ksf, Tributary Width = 1.0 ft, (Wind) Uniform Load : L = 1.490 k/ft, Extent = 0.0 -->> 1.50 ft, Tributary Width = 1.0 ft, (Bearing Load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.239: 1 Load Combination +D+0.750Lr+0.750L+0.450W Span # where maximum occurs Span # 1 Location of maximum on span 4.250ft 46.53 psi= = 1,728.00psi 4x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+0.750Lr+0.750L+0.450W= = = 288.00 psi== Section used for this span 4x10 Maximum Shear Stress Ratio 0.162 : 1 4.250ft== 413.26psi Maximum Deflection 5571 >=360 1446Ratio =5205 >=180 Max Downward Transient Deflection 0.066 in 1632Ratio =>=360 Max Upward Transient Deflection -0.009 in Ratio = Max Downward Total Deflection 0.075 in Ratio =>=180 Max Upward Total Deflection -0.010 in fb: Actual Fb: Allowable fv: Actual Fv: Allowable Span: 2 : L Only Span: 1 : L Only Span: 2 : +D+L Span: 1 : +D+L .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length D Only 0.00 0.00 0.000.00 1.00Length = 4.250 ft 1 0.045 0.019 0.90 1.200 1.00 1.00 1.00 0.18 43.82 972.00 0.07 162.001.00 3.13 1.00Length = 4.50 ft 2 0.045 0.019 0.90 1.200 1.00 1.00 1.00 0.18 43.82 972.00 0.07 162.001.00 3.13 1.00+D+Lr 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 4.250 ft 1 0.069 0.029 1.25 1.200 1.00 1.00 1.00 0.38 92.50 1350.00 0.14 225.001.00 6.60 1.00Length = 4.50 ft 2 0.069 0.029 1.25 1.200 1.00 1.00 1.00 0.38 92.50 1350.00 0.14 225.001.00 6.60 1.00+D+0.750Lr+0.750L 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 4.250 ft 1 0.221 0.154 1.60 1.200 1.00 1.00 1.00 1.59 382.59 1728.00 0.96 288.001.00 44.34 1.00Length = 4.50 ft 2 0.221 0.154 1.60 1.200 1.00 1.00 1.00 1.59 382.59 1728.00 0.96 288.001.00 44.34 2.1.19 Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-8 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length 1.00+D+0.750L 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 4.250 ft 1 0.200 0.145 1.60 1.200 1.00 1.00 1.00 1.44 346.08 1728.00 0.90 288.001.00 41.74 1.00Length = 4.50 ft 2 0.200 0.145 1.60 1.200 1.00 1.00 1.00 1.44 346.08 1728.00 0.90 288.001.00 41.74 1.00+D+0.750Lr+0.750L+0.450W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 4.250 ft 1 0.239 0.162 1.60 1.200 1.00 1.00 1.00 1.72 413.26 1728.00 1.00 288.001.00 46.53 1.00Length = 4.50 ft 2 0.239 0.162 1.60 1.200 1.00 1.00 1.00 1.72 413.26 1728.00 1.00 288.001.00 46.53 1.00+D+0.750Lr+0.750L-0.450W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 4.250 ft 1 0.204 0.146 1.60 1.200 1.00 1.00 1.00 1.46 351.92 1728.00 0.91 288.001.00 42.16 1.00Length = 4.50 ft 2 0.204 0.146 1.60 1.200 1.00 1.00 1.00 1.46 351.92 1728.00 0.91 288.001.00 42.16 1.00+D+0.750L+0.450W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 4.250 ft 1 0.218 0.153 1.60 1.200 1.00 1.00 1.00 1.57 376.75 1728.00 0.95 288.001.00 43.931.00Length = 4.50 ft 2 0.218 0.153 1.60 1.200 1.00 1.00 1.00 1.57 376.75 1728.00 0.95 288.001.00 43.93 1.00+D+0.750L-0.450W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 4.250 ft 1 0.183 0.137 1.60 1.200 1.00 1.00 1.00 1.31 315.41 1728.00 0.85 288.001.00 39.55 1.00Length = 4.50 ft 2 0.183 0.137 1.60 1.200 1.00 1.00 1.00 1.31 315.41 1728.00 0.85 288.001.00 39.551.00+0.60D+0.60W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 4.250 ft 1 0.039 0.017 1.60 1.200 1.00 1.00 1.00 0.28 67.19 1728.00 0.10 288.001.00 4.79 1.00Length = 4.50 ft 2 0.039 0.017 1.60 1.200 1.00 1.00 1.00 0.28 67.19 1728.00 0.10 288.001.00 4.791.00+0.60D-0.60W 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 4.250 ft 1 0.009 0.005 1.60 1.200 1.00 1.00 1.00 0.06 15.44 1728.00 0.03 288.001.00 1.35 1.00Length = 4.50 ft 2 0.008 0.005 1.60 1.200 1.00 1.00 1.00 0.06 14.61 1728.00 0.02 288.001.00 1.35 1.00+0.60D 1.200 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 4.250 ft 1 0.015 0.007 1.60 1.200 1.00 1.00 1.00 0.11 26.29 1728.00 0.04 288.001.00 1.88 1.00Length = 4.50 ft 2 0.015 0.007 1.60 1.200 1.00 1.00 1.00 0.11 26.29 1728.00 0.04 288.001.00 1.88 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+L10.0000 0.000 -0.0098 2.469 +D+L 2 0.0746 4.500 0.0000 2.469 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum -0.399 2.792 Overall MINimum -0.005 0.193 D Only -0.005 0.162 +D+L -0.399 2.792 +D+Lr -0.010 0.342 +D+0.750Lr+0.750L -0.304 2.269 +D+0.750L -0.300 2.134 +D+0.60W -0.045 0.278 +D+0.750Lr+0.750L+0.450W -0.334 2.356 +D+0.750L+0.450W -0.330 2.221 +0.60D+0.60W -0.043 0.213 +0.60D -0.003 0.097 Lr Only -0.005 0.180 L Only -0.394 2.629 W Only -0.067 0.193 2.1.20 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 2.1.21 Hilton Arcadia Framing Checks 8/24 19-0283-02 CWH Main Span: Roof Dead Load = 18psf x (1') = 18plf Roof Live Load = 20psf x (1') = 20plf Cantilever: Roof Dead Load = 18psf x (3.5') = 63plf Roof Live Load = 20psf x (3.5') = 70plf Bearing Plate Load: P = 6700#/2legs = 3350# Reaction from Joist 1: 3350#(1.5'/2)/5' = 502.5# Reaction from Joist 2: 3350#(1.5'/2)/2' = 1256 # Wind Load = 28psf(3.5) = 98plf RJ-9 D+Lr 11' - 3" 6' - 3"28psf 5' 2' 8" 4.75' 503#1256# RJ - 9 D+Lr 3.5' Fulcrum Loads Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-9 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.0180, Lr = 0.020 , Tributary Width = 1.0 ft, (Roof Load) Point Load : L = -0.5030 k @ 0.670 ft, (Fulcrum Load) Point Load : L = -1.256 k @ 4.750 ft, (Fulcrum Load) Load for Span Number 2 Uniform Load : W = 0.0280 ksf, Tributary Width = 3.50 ft, (Wind) Uniform Load : D = 0.0180, Lr = 0.020 ksf, Tributary Width = 3.50 ft, (Roof Load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.493: 1 Load Combination +D+0.750Lr+0.750L+0.450W Span # where maximum occurs Span # 1 Location of maximum on span 4.749ft 30.52 psi= = 1,440.00psi 2-2x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr= = = 225.00 psi== Section used for this span 2-2x10 Maximum Shear Stress Ratio 0.136 : 1 6.250ft= = 710.33psi Maximum Deflection 2674 >=360 514Ratio =1670 >=180 Max Downward Transient Deflection 0.111 in 1078Ratio =>=360 Max Upward Transient Deflection -0.028 in Ratio = Max Downward Total Deflection 0.233 in Ratio =>=180 Max Upward Total Deflection -0.045 in fb: Actual Fb: Allowable fv: Actual Fv: Allowable Span: 2 : W Only Span: 1 : L Only Span: 2 : +D+0.750Lr+0.750L+0.450W Span: 1 : +D+0.750Lr+0.750L+0.450W .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length D Only 0.00 0.00 0.000.00 1.00Length = 6.250 ft 1 0.273 0.089 0.90 1.000 1.00 1.00 1.00 0.79 220.89 810.00 0.27 162.001.00 14.46 1.00Length = 5.0 ft 2 0.273 0.089 0.90 1.000 1.00 1.00 1.00 0.79 220.89 810.00 0.27 162.001.00 14.46 1.00+D+Lr 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 6.250 ft 1 0.415 0.136 1.25 1.000 1.00 1.00 1.00 1.66 466.33 1125.00 0.56 225.001.00 30.52 1.00Length = 5.0 ft 2 0.415 0.136 1.25 1.000 1.00 1.00 1.00 1.66 466.33 1125.00 0.56 225.001.00 30.52 1.00+D+0.750Lr+0.750L 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 2.1.22 Wood Beam LIC# : KW-06014612, Build:20.22.6.12 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2022 DESCRIPTION:RJ-9 Project File: 19-0283-01 hilton arcadia bldg d framing_revised_backup_1_backup_1.ec6 Project Title:Engineer:Project ID:Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination Ci CLCCCCF/V mr td Shear ValuesMax Stress Ratios M CV fbM fvF'b V F'vSegment Length 1.00Length = 6.250 ft 1 0.412 0.092 1.60 1.000 1.00 1.00 1.00 2.11 592.85 1440.00 0.49 288.001.00 26.51 1.00Length = 5.0 ft 2 0.281 0.092 1.60 1.000 1.00 1.00 1.00 1.44 404.97 1440.00 0.49 288.001.00 26.51 1.00+D+0.750L 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 6.250 ft 1 0.325 0.113 1.60 1.000 1.00 1.00 1.00 1.67 467.99 1440.00 0.60 288.001.00 32.461.00Length = 5.0 ft 2 0.153 0.113 1.60 1.000 1.00 1.00 1.00 0.79 220.89 1440.00 0.27 288.001.00 32.46 1.00+D+0.750Lr+0.750L+0.450W 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 6.250 ft 1 0.493 0.127 1.60 1.000 1.00 1.00 1.00 2.53 710.33 1440.00 0.68 288.001.00 36.63 1.00Length = 5.0 ft 2 0.389 0.127 1.60 1.000 1.00 1.00 1.00 1.99 559.59 1440.00 0.68 288.001.00 36.63 1.00+D+0.750Lr+0.750L-0.450W 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 6.250 ft 1 0.330 0.105 1.60 1.000 1.00 1.00 1.00 1.69 475.37 1440.00 0.56 288.001.00 30.21 1.00Length = 5.0 ft 2 0.174 0.105 1.60 1.000 1.00 1.00 1.00 0.89 250.34 1440.00 0.30 288.001.00 30.211.00+D+0.750L+0.450W 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 6.250 ft 1 0.407 0.096 1.60 1.000 1.00 1.00 1.00 2.09 585.47 1440.00 0.51 288.001.00 27.69 1.00Length = 5.0 ft 2 0.261 0.096 1.60 1.000 1.00 1.00 1.00 1.34 375.51 1440.00 0.45 288.001.00 27.69 1.00+D+0.750L-0.450W 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 6.250 ft 1 0.243 0.129 1.60 1.000 1.00 1.00 1.00 1.25 350.51 1440.00 0.69 288.001.00 37.23 1.00Length = 5.0 ft 2 0.046 0.129 1.60 1.000 1.00 1.00 1.00 0.24 66.27 1440.00 0.08 288.001.00 37.23 1.00+0.60D+0.60W 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.001.00Length = 6.250 ft 1 0.235 0.077 1.60 1.000 1.00 1.00 1.00 1.21 338.70 1440.00 0.41 288.001.00 22.17 1.00Length = 5.0 ft 2 0.235 0.077 1.60 1.000 1.00 1.00 1.00 1.21 338.70 1440.00 0.41 288.001.00 22.17 1.00+0.60D-0.60W 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 6.250 ft 1 0.051 0.017 1.60 1.000 1.00 1.00 1.00 0.26 73.63 1440.00 0.09 288.001.00 4.821.00Length = 5.0 ft 2 0.051 0.017 1.60 1.000 1.00 1.00 1.00 0.26 73.63 1440.00 0.09 288.001.00 4.82 1.00+0.60D 1.000 1.00 1.00 1.00 0.00 0.00 0.001.00 0.00 1.00Length = 6.250 ft 1 0.092 0.030 1.60 1.000 1.00 1.00 1.00 0.47 132.53 1440.00 0.16 288.001.00 8.681.00Length = 5.0 ft 2 0.092 0.030 1.60 1.000 1.00 1.00 1.00 0.47 132.53 1440.00 0.16 288.001.00 8.68 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L+0.450W10.0000 0.000 -0.0449 3.561 +D+0.750Lr+0.750L+0.450W 2 0.2329 5.000 0.0000 3.561 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum -0.820 1.050 Overall MINimum -0.070 0.686 D Only -0.070 0.497 +D+L -0.820 -0.511 +D+Lr -0.147 1.050 +D+0.750Lr+0.750L -0.691 0.155 +D+0.750L -0.633 -0.259 +D+0.60W -0.187 0.909 +D+0.750Lr+0.750L+0.450W -0.779 0.464 +D+0.750L+0.450W -0.721 0.050 +0.60D+0.60W -0.159 0.710 +0.60D -0.042 0.298 Lr Only -0.077 0.553 L Only -0.751 -1.008 W Only -0.196 0.686 2.1.23 Structural Calculations Scope: Exterior Building Maintenance Rev 0: May 29, 2024 Hilton Arcadia 123 W Huntington Dr. Arcadia, CA 91007 Project: 55662 05/29/2024 1 Hilton Arcadia Structural Calculations 123 W Huntington Dr Arcadia, CA 91007 Project: 55662 2 Contents PROJECT SUMMARY __________________________________________________________________ 3 BUILDING CODE ______________________________________________________________________ 3 ASSUMPTIONS _______________________________________________________________________ 3 DESIGN CRITERA _____________________________________________________________________ 4 ANALYSIS APPROACH _________________________________________________________________ 4 2 Hilton Arcadia Structural Calculations 123 W Huntington Dr Arcadia, CA 91007 Project: 55662 3 Project Summary Equipment is to be installed on the roof of the Hilton Arcadia Building to be used by workers performing exterior building maintenance (EBM). Equipment is defined under the Analysis Approach section. Applicable Code 2022 California Building Code (CBC) – Building Code with amendments by the City of Arcadia. 1. Section 1607.9 – Loads on Handrails, Guards, Grab Bars and Seats. 2. Section 1607.11.3 – Elements Supporting Hoists for Façade Access and Building Maintenance Equipment. 3. Section 1607.11.4 – Fall Arrest and Lifeline Anchorages. California Code of Regulations (CCR) – Title 8 1. Subchapter 4. Construction Safety Orders (Sections 1500 – 1962) a. Article 24 – Fall Protection (Sections 1669 – 1672) 2. Subchapter 7. General Industry Safety Orders (Sections 3200 – 3299) a. Article 2 – Standard Specifications (Sections 3209 – 3239) b. Article 4 – Access, Workspace and Work Areas (Sections 3270 – 3280) c. Article 5 – Window Cleaning (Sections 3281 – 3291) d. Article 6 – Powered Platforms and Equipment for Building Maintenance (Sections 3292 – 3299) ASCE 7-16, Minimum Design Loads for Buildings and Other Structures. American Institute of Steel Construction, Inc, – Steel Construction Manual, 15th Edition. National Design Specifications for Wood Construction – 2022 Edition. CAL/OSHA Title 8, Section 3282 (all) and Section 3291(c), (d), and (e). OSHA Standard 1910 Subpart I – Personal Protective Equipment Assumptions The following are assumptions taken for design. 1. All information and documentation provided by the owner, manufacturers, client, and others pertaining to this fall restraint system installation project are accurate. 2. Safety Factors as specified are maintained for all fall arrest designs per Code requirements. 3. A maximum of one (1) worker, weighing not more than 310 pounds, including tools, will be attached to each rooftop tie-back anchor at a time for fall arrest purposes. 4. A maximum of 1,000 lbs. will be loaded onto the cantilevered ends of the outrigger assemblies. 5. This analysis does not verify the capacities of the personal fall restraint and arrest systems. 6. This fall protection system and attachment design is intended for use in this referenced project location only and with the specified materials and products only. 7. The existing roof and building framing members to which the fall protection system will be attached are in sound structural condition and meet or exceed the member sizes to be field verified. 3 Hilton Arcadia Structural Calculations 123 W Huntington Dr Arcadia, CA 91007 Project: 55662 4 Design Criteria 1. Tie-back anchors to be designed for 5,000 lbs. Ultimate load (CCR Section 3291 & CCR Section 1670) or 3100 Service load for wood and steel design (CBC 1607), applied in any direction with no permanent deformation. 2. Outrigger assemblies to be designed for 4,000 lbs. Ultimate load (CCR Section 3291) (1,000 lbs. working load with a 4.0 factor of safety) to be loaded at the cantilevered end. Analysis Approach 1. Tie-back anchor design and analysis and attachment to the wood framed roof includes: a. Pad-eye i. Page 6 b. Cap Plate i. Page 9 c. Stanchion i. Page 17 d. Baseplate i. Page 19 e. Fasteners/bolts i. Page 20 f. Welding of assembly pieces i. Within Each Component Above 2. Fixed Outrigger design and analysis and attachment to the wood framed roof includes: a. Outrigger permanent base (tie-back anchor governs above) b. Outrigger support post i. Page 21 c. Outrigger beam i. Page 24 d. Fasteners/bolts (tie-back anchor governs above) The design of the roof structure will be designed by the parent building structural engineer of record and is beyond this scope. 4 Job #: 55662 Padeye Job Name: Hilton Arcadia 4.0 Std. Pipe Attachment Ultimate Load (P)5000 lbs (LRFD) Rated Load 1250 lbs Height of Stanchion (H)20 in DESIGN CALCULATIONS AND ANALYSIS Design Methodology: This calculation provides structural analysis for roof anchor components and qualifications using the provisions of LRFD strength design according to the AISC 360-15 Specification and other industry recognized standards referenced within. As such, the equivalent ASD design load considered can be taken as the Ultimate Load (P) divided by the IBC live load factor of 1.6 if using this calculation to determine an equivalent ASD reaction. P (applied in any direction) H 5 Padeye Bar Equivalent (du)0.875 in Center-to-Center Width (Wu)2.875 in Height to Applied Load (Hu)2 in Fillet Weld Leg Size (w1)0.25 in Plug Weld Effective Throat 0.125 in resists shear only Minimum Yield Stress (Fy,u)54 ksi AISI 1018 Minimum Tensile Strength (Fu,u)64 ksi AISI 1018 A (in2)Ione (in4) Itwo (in4) Sx (in3) Zx (in3)r (in) 0.766 0.049 3.262 0.223 0.335 0.253 Design Tensile Strength, ϕRnt 37.21 kip AISC Eq. D2-1 Design Tensile Strength, ϕRntnet 36.75 kip AISC Eq. D2-2 Unity Check: 0.14 P/min(ϕRnt) FReaction (P/4) =1250 lbs Reaction Forces for Risa Design Shear Strength, ϕRnv 37.21 kip AISC Eq. G4-1 Unity Check: 0.13 Rcv/ϕRnv DESIGN OF PADEYE Padeye Properties Padeye in Tension (Load Case P3) Padeye in Shear (Load Case P2) Conservatively considers one leg of Padeye resists the applied load. Conservatively considers one leg of Padeye resists the applied load. w1 Hu P2 P1 P3 6 Design Strength of Padeye, ϕMnb 10.85 kip-in AISC Eq. F11-1 (Use S x) Lateral-Torsional Buckling does not apply per F11.2.d Required Flexural Strength, Mrb 9.38 kip-in P*1-7/8" Unity Check: 0.86 Mrb/ϕMnb FReaction (Mrb / 2B) =1705 lbs Reaction Forces for Risa Required Axial Strength (Pr) 3.48 kip P*(Hu)/wu Required Flexural Strength (Mr) 18.75 kip-in P/2*(Hu) Available Axial Strength (Pc) 36.75 kip ϕMnb Available Flexural Strength (Mc) 99.67 kip-in ϕRnt Interaction Ratio: 0.24 AISC Eq. H1-1b FReaction (Mr / 2t) =10714 lbs Reaction Forces for Risa Flexure Strength Padeye Leg, ϕMnl 10.85 kip-in AISC Eq. F11-1 (Use S x) Required Flexural Strength, Mrl 5 kip-in P*Hu/2 Unity Check: 0.46 Mrl/ϕMnl Electrode Strength (Fexx) 70 ksi Length of Fillet Weld (l)3.75 in Moment of inertia about axis (Ix)8.79 in3 2l 3 / 12 Maximum Vertical Force (Vp)0.67 kips/in P r / 2l Maximum Horizontal Force (He)2.13 kips/in P reyi / I x Required Force 2.24 kips/in √(Vp^2+H e ^2) Available Strength of Fillet (qu)1.39 kip/in/sixteenth Required Fillet Weld Size (D) 1.61 sixteenths R / q u Unity Check: 0.40 D/16 / w 1 Electrode Strength (Fexx) 70 ksi Length of Fillet Weld (Lw2) 9.25 in π*du Section Modulus of Weld (Sw2) 3.41 in2 Blodgett 7.4-7, Table 5 Required Force Per Inch 4.89 kip/in √(fvv^2+(fvt+fvm)^2) Strength of Weld per Inch, ϕRnw 5.57 kip/in AISC Eq. J2-4 & J2-5 Strength of Base Metal, ϕRnb 6.56 kip/in AISC Eq. J2-2 Unity Check: 0.88 Padeye Weld to Cap Plate (Load Case P1) Padeye Weld to Cap Plate (Load Case P2) Padeye Local Leg Bending (Load Case P1) Consider Padeye leg is a simple span with one support at the welded connection and the other support at the center of the Padeye where support is provided from the adjacent leg. Padeye in Weak Axis Flexure (Load Case P2) Considers maximum height of applied load at top of padeye, two legs of Padeye resisting at center of Padeye Padeye in Tension/Compression and Flexure (Load Case P1) 7 Electrode Strength (Fexx) 70 ksi Fillet Weld Leg Size (w1)0.25 in Length of Fillet Weld (Lw1) 14.14 in π*dc Section Modulus of Weld (Sw1)' 15.90 in2 Blodgett 7.4-7, Table 5 Torsional Constant (J) 71.57 in3 Blodgett 7.4-7, Table 5 Required Force Per Inch 0.75 kip/in √((fvv+fvj)^2+(fvt+fvm)^2) Strength of Weld per Inch, ϕRnw 5.57 kip/in AISC Eq. J2-4 Strength of Base Metal, ϕRnb 10.28 kip/in AISC Eq. J2-2 Unity Check: 0.13 Cap Plate Weld to Stanchion (Load Case P2) 8 Diversified Fall Protection bZilber Stanchion cap plate SK-1 Jul 17, 2023 padeye calc.r3dJOB #: 55662 9 Diversified Fall Protection bZilber Stanchion cap plate SK-2 Jul 17, 2023 padeye calc.r3dJOB #: 55662 10 Diversified Fall Protection bZilber Stanchion cap plate SK-3 Jul 17, 2023 padeye calc.r3dJOB #: 55662 11 Diversified Fall Protection bZilber Stanchion cap plate SK-4 Jul 17, 2023 padeye calc.r3dJOB #: 55662 12 Company Designer Job Number Model Name : : : : Diversified Fall Protection bZilber Stanchion cap plate Checked By : __________ 7/17/2023 1:24:14 PM RISA-3D Version 20 [ padeye calc.r3d ]Page 1 Plate Primary Data Label A Node B Node C Node D Node Material Thickness [in] 1 P13 N37 N38 N39 N5 gen_Steel 0.5 2 P5 N24 N25 N26 N27 gen_Steel 0.5 3 P23 N17 N16 N41 N37 gen_Steel 0.5 4 P18 N45 N46 N3 N47 gen_Steel 0.5 5 P12 N33 N36 N1 N2 gen_Steel 0.5 6 P29 N25 N24 N14 N13 gen_Steel 0.5 7 P24 N34 N19 N21 N6 gen_Steel 0.5 8 P25 N2 N20 N32 N33 gen_Steel 0.5 9 P14 N1 N18 N9 N31 gen_Steel 0.5 10 P37 N3 N46 N43 N44 gen_Steel 0.5 11 P28 N13 N22 N28 N25 gen_Steel 0.5 12 P4 N22 N13 N7 N23 gen_Steel 0.5 13 P34 N40 N43 N48 N38 gen_Steel 0.5 14 P8 N32 N24 N27 N33 gen_Steel 0.5 15 P3 N19 N20 N2 N21 gen_Steel 0.5 16 P31 N24 N32 N34 N14 gen_Steel 0.5 17 P36 N48 N45 N47 N8 gen_Steel 0.5 18 P16 N43 N40 N42 N44 gen_Steel 0.5 19 P9 N21 N2 N30 N10 gen_Steel 0.5 20 P1 N13 N14 N15 N7 gen_Steel 0.5 21 P21 N41 N16 N1 N36 gen_Steel 0.5 22 P10 N14 N34 N6 N15 gen_Steel 0.5 23 P38 N46 N45 N48 N43 gen_Steel 0.5 24 P2 N16 N17 N18 N1 gen_Steel 0.5 25 P6 N4 N28 N11 N29 gen_Steel 0.5 26 P30 N28 N4 N26 N25 gen_Steel 0.5 27 P35 N44 N26 N4 N3 gen_Steel 0.5 28 P27 N28 N22 N23 N11 gen_Steel 0.5 29 P26 N20 N19 N34 N32 gen_Steel 0.5 30 P32 N36 N33 N27 N42 gen_Steel 0.5 31 P19 N38 N48 N8 N39 gen_Steel 0.5 32 P33 N41 N40 N38 N37 gen_Steel 0.5 33 P15 N40 N41 N36 N42 gen_Steel 0.5 34 P17 N26 N44 N42 N27 gen_Steel 0.5 35 P11 N3 N4 N29 N35 gen_Steel 0.5 36 P22 N18 N17 N37 N5 gen_Steel 0.5 37 P20 N47 N3 N35 N12 gen_Steel 0.5 38 P7 N30 N2 N1 N31 gen_Steel 0.5 Load Combinations Description Solve P-Delta BLC Factor BLC Factor 1 Tension Yes Y 3 1 2 Perpendicular Load Yes Y 1 1 3 Parallel Load Yes Y 2 1 4 Diagonal Load Yes Y 2 0.71 3 0.71 Envelope Plate Principal Stresses Plate Surface Sigma1 [ksi] LC Sigma2 [ksi] LC Tau Max [ksi] LC Angle [rad] LC Von Mises [ksi] LC 1 P13 max T 2.391 1 -0.183 2 1.559 1 1.162 1 2.826 1 2 min 0.801 3 -1.836 3 0.906 2 0.404 3 1.729 2 3 max B 1.836 3 -0.801 3 1.559 1 1.975 3 2.826 1 4 min 0.183 2 -2.391 1 0.906 2 -0.748 4 1.729 2 55662 MMB 13 Company Designer Job Number Model Name : : : : Diversified Fall Protection bZilber Stanchion cap plate Checked By : __________ 7/17/2023 1:24:14 PM RISA-3D Version 20 [ padeye calc.r3d ]Page 2 Envelope Plate Principal Stresses (Continued) Plate Surface Sigma1 [ksi] LC Sigma2 [ksi] LC Tau Max [ksi] LC Angle [rad] LC Von Mises [ksi] LC 5 P5 max T 7.132 2 -2.588 2 4.86 2 2.308 3 8.718 2 6 min -2.1 1 -4.574 4 0.852 1 -0.632 4 3.3 1 7 max B 4.574 4 2.1 1 4.86 2 1.412 1 8.718 2 8 min 2.588 2 -7.132 2 0.852 1 -0.04 2 3.3 1 9 P23 max T 4.157 3 -0.133 3 4.145 2 1.913 1 8.971 2 10 min -1.745 1 -9.525 2 0.316 1 -0.468 2 2.133 1 11 max B 9.525 2 1.745 1 4.145 2 2.111 4 8.971 2 12 min 0.133 3 -4.157 3 0.316 1 0.342 1 2.133 1 13 P18 max T -2.149 3 -4.471 1 2.428 2 1.276 3 17.121 2 14 min -14.168 2 -19.024 2 0.885 1 0.828 2 3.9 1 15 max B 19.024 2 14.168 2 2.428 2 -0.295 3 17.121 2 16 min 4.471 1 2.149 3 0.885 1 -0.742 2 3.9 1 17 P12 max T 8.646 3 8.034 3 2.396 2 0.816 2 8.357 3 18 min -5.438 1 -7.409 1 0.306 3 -0.101 3 2.086 4 19 max B 7.409 1 5.438 1 2.396 2 1.583 1 8.357 3 20 min -8.034 3 -8.646 3 0.306 3 -0.755 2 2.086 4 21 P29 max T 7.509 2 0.015 2 3.747 2 2.188 3 7.502 2 22 min -1.055 1 -3.803 4 0.603 1 1.263 2 1.96 1 23 max B 3.803 4 1.055 1 3.747 2 0.617 3 7.502 2 24 min -0.015 2 -7.509 2 0.603 1 -0.308 2 1.96 1 25 P24 max T 8.413 2 0.281 2 4.066 2 2.29 4 8.276 2 26 min 1.849 4 -2.152 1 0.978 4 -0.373 2 1.905 4 27 max B 2.152 1 -1.849 4 4.066 2 1.319 3 8.276 2 28 min -0.281 2 -8.413 2 0.978 4 0.04 1 1.905 4 29 P25 max T 17.892 2 6.209 2 5.842 2 1.556 2 15.735 2 30 min -3.728 1 -5.317 1 0.794 1 -0.607 3 1.867 4 31 max B 5.317 1 3.728 1 5.842 2 1.861 1 15.735 2 32 min -6.209 2 -17.892 2 0.794 1 -0.015 2 1.867 4 33 P14 max T 4.486 1 -0.257 4 3.627 2 0.624 1 10.576 2 34 min -4.88 2 -12.135 2 0.906 4 -0.728 3 1.698 4 35 max B 12.135 2 4.88 2 3.627 2 2.195 1 10.576 2 36 min 0.257 4 -4.486 1 0.906 4 0.843 3 1.698 4 37 P37 max T -3.837 1 -5.655 1 6.174 2 0.953 3 16.956 2 38 min -6.985 2 -19.333 2 0.909 1 -0.05 2 5.001 1 39 max B 19.333 2 6.985 2 6.174 2 2.212 4 16.956 2 40 min 5.655 1 3.837 1 0.909 1 -0.618 3 5.001 1 41 P28 max T 9.536 2 6.942 2 2.255 3 1.775 3 8.54 2 42 min -0.709 1 -4.94 4 1.07 1 0.934 2 2.569 1 43 max B 4.94 4 0.709 1 2.255 3 0.204 3 8.54 2 44 min -6.942 2 -9.536 2 1.07 1 -0.636 2 2.569 1 45 P4 max T 3.056 4 -1.551 1 2.809 4 1.791 3 4.906 2 46 min 1.673 3 -3.525 2 1.947 3 0.133 2 3.383 3 47 max B 3.525 2 -1.673 3 2.809 4 1.703 2 4.906 2 48 min 1.551 1 -3.056 4 1.947 3 -0.064 1 3.383 3 49 P34 max T 1.374 3 -2.326 1 4.057 2 0.963 1 8.599 2 50 min -1.362 1 -9.014 2 0.482 1 0.211 2 2.024 1 51 max B 9.014 2 1.362 1 4.057 2 1.782 2 8.599 2 52 min 2.326 1 -1.374 3 0.482 1 -0.685 3 2.024 1 53 P8 max T 7.056 2 0.214 3 4.386 2 2.346 3 8.053 2 54 min -2.208 1 -4.313 1 1.053 1 -0.456 4 2.337 4 55 max B 4.313 1 2.208 1 4.386 2 1.632 1 8.053 2 56 min -0.214 3 -7.056 2 1.053 1 -0.066 2 2.337 4 57 P3 max T 17.956 2 13.248 2 2.354 2 2.348 2 16.126 2 58 min -2.575 1 -4.685 1 0.918 4 -0.305 3 1.691 4 59 max B 4.685 1 2.575 1 2.354 2 1.271 4 16.126 2 MMB55662 14 Company Designer Job Number Model Name : : : : Diversified Fall Protection bZilber Stanchion cap plate Checked By : __________ 7/17/2023 1:24:14 PM RISA-3D Version 20 [ padeye calc.r3d ]Page 3 Envelope Plate Principal Stresses (Continued) Plate Surface Sigma1 [ksi] LC Sigma2 [ksi] LC Tau Max [ksi] LC Angle [rad] LC Von Mises [ksi] LC 60 min -13.248 2 -17.956 2 0.918 4 -0.311 1 1.691 4 61 P31 max T 7.808 2 0.461 2 3.674 2 1.748 2 7.588 2 62 min -1.193 1 -2.253 1 0.53 1 -0.756 4 1.952 1 63 max B 2.253 1 1.193 1 3.674 2 0.876 3 7.588 2 64 min -0.461 2 -7.808 2 0.53 1 -0.492 1 1.952 1 65 P36 max T 2.673 4 -1.818 1 4.088 2 1.646 1 8.123 2 66 min 0.106 2 -8.07 2 2.21 1 1.254 2 3.848 1 67 max B 8.07 2 -0.106 2 4.088 2 0.075 1 8.123 2 68 min 1.818 1 -2.673 4 2.21 1 -0.316 2 3.848 1 69 P16 max T 1.441 2 -3.121 3 4.113 2 0.741 3 7.609 2 70 min -2.645 4 -6.785 2 1.164 3 -0.158 2 2.81 3 71 max B 6.785 2 2.645 4 4.113 2 2.312 3 7.609 2 72 min 3.121 3 -1.441 2 1.164 3 1.412 2 2.81 3 73 P9 max T 12.368 2 5.31 2 3.529 2 1.441 2 10.746 2 74 min 1.514 4 -2.857 3 0.854 4 -0.619 1 1.619 4 75 max B 2.857 3 -1.514 4 3.529 2 2.306 3 10.746 2 76 min -5.31 2 -12.368 2 0.854 4 -0.13 2 1.619 4 77 P1 max T 2.417 1 -0.649 4 1.654 1 1.949 3 2.965 1 78 min 0.259 2 -1.215 2 0.737 2 -0.53 2 1.363 2 79 max B 1.215 2 -0.259 2 1.654 1 1.041 2 2.965 1 80 min 0.649 4 -2.417 1 0.737 2 -0.449 1 1.363 2 81 P21 max T 6.752 3 4.112 3 6.046 2 0.6 3 16.498 2 82 min -6.701 2 -18.794 2 0.86 1 -0.256 1 1.862 4 83 max B 18.794 2 6.701 2 6.046 2 2.17 3 16.498 2 84 min -4.112 3 -6.752 3 0.86 1 1.314 1 1.862 4 85 P10 max T 2.221 1 -0.823 1 1.522 1 2.308 4 2.727 1 86 min 0.102 2 -1.688 3 0.635 2 -0.401 3 1.223 2 87 max B 1.688 3 -0.102 2 1.522 1 2.034 2 2.727 1 88 min 0.823 1 -2.221 1 0.635 2 0.41 1 1.223 2 89 P38 max T 0.105 3 -2.286 1 4.259 2 1.324 1 9.209 2 90 min -1.852 1 -9.773 2 0.217 1 0.481 2 2.103 1 91 max B 9.773 2 1.852 1 4.259 2 2.051 2 9.209 2 92 min 2.286 1 -0.105 3 0.217 1 -0.51 3 2.103 1 93 P2 max T 6.817 3 2.268 3 2.31 2 1.867 1 16.528 2 94 min -13.727 2 -18.346 2 0.898 4 -0.759 2 1.663 4 95 max B 18.346 2 13.727 2 2.31 2 1.859 3 16.528 2 96 min -2.268 3 -6.817 3 0.898 4 0.296 1 1.663 4 97 P6 max T 21.492 2 11.74 2 4.876 2 1.714 2 18.639 2 98 min 1.996 3 -2.964 4 2.178 3 0.719 1 3.776 3 99 max B 2.964 4 -1.996 3 4.876 2 2.29 1 18.639 2 100 min -11.74 2 -21.492 2 2.178 3 -0.759 4 3.776 3 101 P30 max T 27.992 2 15.572 2 6.21 2 2.168 4 24.293 2 102 min -6.662 4 -11.447 4 1.095 1 -0.774 1 6.127 1 103 max B 11.447 4 6.662 4 6.21 2 0.797 1 24.293 2 104 min -15.572 2 -27.992 2 1.095 1 -0.262 2 6.127 1 105 P35 max T 3.244 2 -3.058 2 3.151 2 2.266 2 10.311 4 106 min -9.958 4 -10.632 4 0.337 4 -0.488 4 5.459 2 107 max B 10.632 4 9.958 4 3.151 2 1.475 1 10.311 4 108 min 3.058 2 -3.244 2 0.337 4 0.202 3 5.459 2 109 P27 max T 3.874 2 -0.312 3 2.254 2 2.064 2 4.227 2 110 min 2.625 3 -0.634 2 1.468 3 0.499 1 2.794 3 111 max B 0.634 2 -2.625 3 2.254 2 2.266 4 4.227 2 112 min 0.312 3 -3.874 2 1.468 3 -0.647 3 2.794 3 113 P26 max T 9.457 2 1.34 2 4.059 2 2.049 2 8.864 2 114 min -1.765 1 -2.468 1 0.351 1 -0.55 4 2.202 1 MMB LESS THAN 50 KSI 55662 15 Company Designer Job Number Model Name : : : : Diversified Fall Protection bZilber Stanchion cap plate Checked By : __________ 7/17/2023 1:24:14 PM RISA-3D Version 20 [ padeye calc.r3d ]Page 4 Envelope Plate Principal Stresses (Continued) Plate Surface Sigma1 [ksi] LC Sigma2 [ksi] LC Tau Max [ksi] LC Angle [rad] LC Von Mises [ksi] LC 115 max B 2.468 1 1.765 1 4.059 2 1.056 3 8.864 2 116 min -1.34 2 -9.457 2 0.351 1 -0.33 1 2.202 1 117 P32 max T 4.46 2 1.158 3 4.755 2 0.839 2 8.241 2 118 min -2.103 1 -5.05 2 0.258 3 -0.754 3 1.485 3 119 max B 5.05 2 2.103 1 4.755 2 1.584 1 8.241 2 120 min -1.158 3 -4.46 2 0.258 3 -0.732 2 1.485 3 121 P19 max T 2.397 1 -0.136 2 1.577 1 1.996 2 2.852 1 122 min 1.656 2 -0.843 3 0.896 2 1.152 3 1.728 2 123 max B 0.843 3 -1.656 2 1.577 1 0.425 2 2.852 1 124 min 0.136 2 -2.397 1 0.896 2 -0.418 3 1.728 2 125 P33 max T 3.05 3 -1.328 3 3.949 2 2.202 1 8.375 2 126 min -1.392 1 -8.782 2 0.483 1 -0.192 2 2.054 1 127 max B 8.782 2 1.392 1 3.949 2 2.278 4 8.375 2 128 min 1.328 3 -3.05 3 0.483 1 0.631 1 2.054 1 129 P15 max T 2.846 3 0.451 3 4.071 2 0.834 3 7.443 2 130 min -2.211 1 -6.454 2 1.106 4 -0.043 1 2.303 4 131 max B 6.454 2 2.211 1 4.071 2 1.957 4 7.443 2 132 min -0.451 3 -2.846 3 1.106 4 -0.737 3 2.303 4 133 P17 max T 7.511 2 -2.19 2 4.851 2 2.138 2 8.813 2 134 min -2.724 4 -5.262 1 0.52 3 -0.772 3 1.953 3 135 max B 5.262 1 2.724 4 4.851 2 1.519 1 8.813 2 136 min 2.19 2 -7.511 2 0.52 3 0.568 2 1.953 3 137 P11 max T 8.872 2 -7.971 1 11.357 2 0.771 2 19.827 2 138 min -9.948 4 -13.842 2 0.705 3 -0.064 3 7.146 1 139 max B 13.842 2 9.948 4 11.357 2 2.342 2 19.827 2 140 min 7.971 1 -8.872 2 0.705 3 1.507 3 7.146 1 141 P22 max T 3.276 3 -0.153 4 3.958 2 1.896 2 7.806 2 142 min 0.226 2 -7.691 2 1.03 4 0.252 3 1.988 4 143 max B 7.691 2 -0.226 2 3.958 2 1.823 3 7.806 2 144 min 0.153 4 -3.276 3 1.03 4 -0.732 4 1.988 4 145 P20 max T 5 4 -1.518 1 4.481 2 2.294 3 11.851 2 146 min -4.475 2 -13.437 2 2.355 3 -0.718 4 4.107 3 147 max B 13.437 2 4.475 2 4.481 2 1.31 2 11.851 2 148 min 1.518 1 -5 4 2.355 3 0.723 3 4.107 3 149 P7 max T 11.084 3 9.659 3 11.548 2 1.675 3 20.013 2 150 min -7.138 1 -12.203 2 0.213 4 -0.728 2 1.624 4 151 max B 12.203 2 7.138 1 11.548 2 1.64 1 20.013 2 152 min -9.659 3 -11.084 3 0.213 4 0.104 3 1.624 4 MMB55662 16 Height of Stanchion (H) 20 in Pipe Size 4.0 Std. Pipe P4.00 Fillet Weld Leg Size (w3)0.3125 in Minmum Yield Stress (Fy)46 ksi Minimum Tensile Stress (Fu)62 ksi ASTM A500 Gr. C Steel Modulus of Elasticity (E) 29000 ksi AISC Table B4.1b c do di t A I S r Z 4.5 4.03 0.221 2.96 6.82 3.03 1.51 4.05 in in in in2 in4 in2 in in2 Required Strength in Shear (Vr) 5 kip Critical Shear Stress (Fcr) 27.6 ksi AISC Eq. G5-2a/b Design Shear Strength (ϕRnv) 36.76 kip AISC Eq. G5-1 Unity Check: 0.14 DESIGN OF ANCHOR STANCHION ASTM A500 Gr. C Stanchion Properties Stanchion in Shear (Load Case P1) H w3 P1 P2 2" 17 Design Tensile Strength (ϕPn) 122.544 kip AISC Eq. D2-1 Unity Check: 0.04 Required Flexural Strength (Mr) 110.00 kip-in D/t ratio 20.36 Compactness Ratio (λp) 44.13 AISC Table B4.1B, Slenderness Ratio (λr) 195.43 Case 20 Compactness in Flexure Compact Design Flexural Strength (ϕRn) 125.442 kip-in AISC Eq. F8-1 (Use S) Unity Check: 0.88 Required Axial Strength (Pr) 0 kip Available Axial Strength (Pc) 122.54 kip Required Flexural Strength (Mr) 110.00 kip-in Available Flexural Strength (Mc) 125.442 kip-in Interaction Ratio 0.88 AISC Eq. H1-1a & 1b Electrode Strength (Fexx) 70 ksi Fillet Weld Leg Size (w3)0.3125 in Section Modulus of Weld (Sw1) 16.80 in2 Blodgett 7.4-7, Table 5 Length of Fillet Weld (Lw1) 14.53 in π*dc Required Force Per Inch 6.56 kip/in √(fvv^2+(fvt+fvm)^2) Strength of Weld per Inch, ϕRnw 10.44 kip/in AISC Eq. J2-4 Strength of Base Metal, ϕRnb 10.28 kip/in AISC Eq. J2-2 Unity Check: 0.64 Stanchion in Tension/Compression and Flexure (Load Case P1) Design of Weld to Base Material, w3 (Load Case P1) AISC F8.2a: Limit State of Flange Local Buckling does not apply Stanchion in Flexure (Load Case P1) Stanchion in Tension (Load Case P2) 18 Loading: Ultimate Load, P = 5000 lbs Height of Stanchion, H = 23.31 in. Anchor Weight, w = 150 lbs Baseplate Data: Base Plate Length, N =12.00 in. Base Plate Width, B =12.00 in. Base Plate Thickness, t =0.63 in Base Plate Steel Grade = ASTM A572 Gr 50 Plate Yield Stress, Fy = 50.00 ksi Base Plate tensile stress, Fu = 65.00 ksi Stanchion Data: Stanchion Size = 4.0 Std. Pipe Stanchion Diameter, d = 4.50 in. Effective Diameter, de =3.60 in. Fastener Data: Bolt Type = A307 0.75 in. Total No. of Bolts, Nb =4 in2 Bolt Area, Ab =0.44 in. Bolt Shear Capacity, Fnv =4420 lbs Bolt Tension Capacity, Fnt =14314 lbs Bolt Edge Distance, de =1.5 in. m = 4.20 in. DESIGN OF 4-BOLT BASE PLATE AND ANCHORAGE (AISC DESIGN GUIDE) Design Information 19 Wood Data: Fc┴ = 625 psi Fc┴ ' = Fc┴ * KF * ø = 939 psi Mu = P * H =117 kip-in e = Mu / w =777.08 in ecrit =5.99 in EQ (3.3.1)<OKAY> f = 4.50 in qmax = Fc┴' * B =11273 lbs/in Y+ =19.96 in EQ (3.4.3) Y- =1.04 in EQ (3.4.3) RT =11.74 kips Tension Force (f + N/2)2 =110.25 in2 EQ (3.4.4) 2Pr (e + f) / qmax =20.80 in2 <OKAY> tp(req) =0.57 in EQ (3.3.15a) x = 2.70 in EQ (3.3.15a) Mpl =2.64 kips-in/in EQ (3.4.5a) tp(req) =0.48 in EQ (3.4.7a) tp(req) =0.53 in AISC EQ (F11-1) Min. Plate Thickness =0.57 in <OKAY> Determine worst case forces on fasteners Tension only (4 screws): Ft = 1250.00 lbs Horizontal Loading (2 bolts in tension, 4 bolts in shear): Ft = 5868 lbs at worst anchor Fv = 1250 lbs at worst anchor F'nt = 13211 lbs <OKAY>EQ (J3-3a) øRn = 9908 lbs <OKAY> Required Plate Washer Size Below Blocking Areq =6.25 in2 Minimum Washer Size Req'd =2.5 in square Base Plate Yielding (AISC Design Guide 3.4) Fastener Check - Wood Deck Only 20 Height of Stanchion (H)22 in Pipe Size 4.0 Std. Pipe P4.00 Fillet Weld Leg Size (w3)0.3125 in Minmum Yield Stress (Fy)46 ksi Minimum Tensile Stress (Fu)62 ksi ASTM A500 Gr. C Steel Modulus of Elasticity (E) 29000 ksi AISC Table B4.1b c do di t A I S r Z 4.5 4.03 0.221 2.96 6.82 3.03 1.51 4.05 in in in in2 in4 in2 in in2 Required Strength in Shear (Vr)3.115 kip Critical Shear Stress (Fcr) 27.6 ksi AISC Eq. G5-2a/b Design Shear Strength (ϕRnv) 36.76 kip AISC Eq. G5-1 Unity Check: 0.08 DESIGN OF ANCHOR STANCHION Stanchion Properties ASTM A500 Gr. C Stanchion in Shear (Load Case P1) H w3 P1 P2 21 Design Tensile Strength (ϕPn) 122.544 kip AISC Eq. D2-1 Unity Check: 0.04 Required Flexural Strength (Mr)40.44 kip-in D/t ratio 20.36 Compactness Ratio (λp) 44.13 AISC Table B4.1B, Slenderness Ratio (λr) 195.43 Case 20 Compactness in Flexure Compact Design Flexural Strength (ϕRn) 125.442 kip-in AISC Eq. F8-1 (Use S) Unity Check: 0.32 Required Axial Strength (Pr) 0 kip Available Axial Strength (Pc) 122.54 kip Required Flexural Strength (Mr) 40.44 kip-in Available Flexural Strength (Mc) 125.442 kip-in Interaction Ratio 0.32 AISC Eq. H1-1a & 1b Electrode Strength (Fexx) 70 ksi Fillet Weld Leg Size (w3)0.3125 in Section Modulus of Weld (Sw1) 16.80 in2 Blodgett 7.4-7, Table 5 Length of Fillet Weld (Lw1) 14.53 in π*dc Required Force Per Inch 2.42 kip/in √(fvv^2+(fvt+fvm)^2) Strength of Weld per Inch, ϕRnw 10.44 kip/in AISC Eq. J2-4 Strength of Base Metal, ϕRnb 10.28 kip/in AISC Eq. J2-2 Unity Check: 0.24 AISC F8.2a: Limit State of Flange Local Buckling does not apply Stanchion in Tension/Compression and Flexure (Load Case P1) Design of Weld to Base Material, w3 (Load Case P1) Stanchion in Tension (Load Case P2) Stanchion in Flexure (Load Case P1) 22 Required Flexural Strength (Mr)40.44 kip-in FBOLT = FWELD = M/b =13.48 kips 1" Diameter SS Pin Capacity = 80.1 kips See AISC Table 7-1 (Double Shear) 17%<OKAY> FWELD (4" Min. of 1/4" Fillet) = 22.27 kips See AISC Table 8-1 (LRFD) 61%<OKAY> Design Outrigger Receiver Connection for Moment at Top of Post 23 Diversified Fall Protection M. Boulant 40342 Fixed Outriggers SK-1 Apr 18, 2023 Fixed Outrigger Template.r3d OUTRIGGER CALCLUATIONS JOB #: 55662 24 Diversified Fall Protection M. Boulant 40342 Fixed Outriggers SK-2 Apr 18, 2023 Fixed Outrigger Template.r3d INCIDENTAL SIDEWAYS LOADING FOR 10 DEGREES MAX PLATFORM DRIFT JOB #: 55662 25 Diversified Fall Protection M. Boulant 40342 Fixed Outriggers SK-3 Apr 18, 2023 Fixed Outrigger Template.r3d INCIDENTAL SIDEWAYS LOADING FOR 10 DEGREES MAX PLATFORM DRIFT JOB #: 55662 26 Company Designer Job Number Model Name : : : : Diversified Fall Protection M. Boulant 40342 Fixed Outriggers Checked By : __________ 4/18/2023 3:24:30 PM RISA-3D Version 20 [ Fixed Outrigger Template.r3d ]Page 1 Node Coordinates Label X [ft] Y [ft] Z [ft] Detach From Diaphragm 1 N1 30 3 0 2 N2 30 3 1.75 3 N3 30 3 6.25 4 N4 30 9 1.75 5 N5 30 9 6.25 6 N6 30 9 0 7 N7 30 2 6.25 8 N8 30 13 6.25 Node Boundary Conditions Node Label X [k/in] Y [k/in] Z [k/in] X Rot [k-ft/rad] Y Rot [k-ft/rad] Z Rot [k-ft/rad] 1 N1 Reaction Reaction Reaction Reaction Reaction Reaction 2 N6 Reaction Reaction Reaction Reaction Reaction Reaction Hot Rolled Steel Properties Label E [ksi] G [ksi] Nu Therm. Coeff. [1e⁵°F⁻¹] Density [k/ft³] Yield [ksi] Ry Fu [ksi] Rt 1 A992 29000 11154 0.3 0.65 0.49 50 1.1 65 1.1 2 A36 Gr.36 29000 11154 0.3 0.65 0.49 36 1.5 58 1.2 3 A572 Gr.50 29000 11154 0.3 0.65 0.49 50 1.1 65 1.1 4 A500 Gr.B RND 29000 11154 0.3 0.65 0.527 42 1.4 58 1.3 5 A500 Gr.B RECT 29000 11154 0.3 0.65 0.527 46 1.4 58 1.3 6 A500 Gr.C RND 29000 11154 0.3 0.65 0.527 46 1.4 62 1.3 7 A500 Gr.C RECT 29000 11154 0.3 0.65 0.527 50 1.4 62 1.3 8 A53 Gr.B 29000 11154 0.3 0.65 0.49 35 1.6 60 1.2 9 A1085 29000 11154 0.3 0.65 0.49 50 1.4 65 1.3 10 A913 Gr.65 29000 11154 0.3 0.65 0.49 65 1.1 80 1.1 Aluminum Properties Label E [ksi] G [ksi] Nu Therm. Coeff. [1e⁵°F⁻¹]Density [k/ft³] Table B.4 kt Ftu [ksi]Fty [ksi]Fcy [ksi]Fsu [ksi] Ct 1 6061-T6 10100 3787.5 0.33 1.3 0.173 Table B.4-1 1 45 35 35 24 141 2 6063-T5 10100 3787.5 0.33 1.3 0.173 Table B.4-2 1 22 16 16 13 141 3 6063-T6 10100 3787.5 0.33 1.3 0.173 Table B.4-2 1 30 25 25 19 141 4 5052-H34 10200 3787.5 0.33 1.3 0.173 Table B.4-1 1 34 26 24 20 141 5 6061-T6 W 10100 3787.5 0.33 1.3 0.173 Table B.4-1 1 24 15 15 15 141 Hot Rolled Steel Section Sets Label Shape Type Design List Material Design Rule Area [in²] Iyy [in⁴] Izz [in⁴] J [in⁴] 1 Base HSS4.500X0.237 Column HSS Pipe A500 Gr.C RND Typical 2.96 6.79 6.79 13.6 2Support Post HSS4X4X4 Column SquareTube A500 Gr.B RECT Typical 3.37 7.8 7.8 12.8 Aluminum Section Sets Label Shape Type Design List Material Design Rule Area [in²] Iyy [in⁴] Izz [in⁴] J [in⁴] 1 Outrigger RT4X6X0.25 Beam Rectangular Tubes 6061-T6 Typical 4.75 12.3 23.5 24.5 55662 27 Company Designer Job Number Model Name : : : : Diversified Fall Protection M. Boulant 40342 Fixed Outriggers Checked By : __________ 4/18/2023 3:24:30 PM RISA-3D Version 20 [ Fixed Outrigger Template.r3d ]Page 2 Member Primary Data Label I Node J Node Section/Shape Type Design List Material Design Rule 1 M1 N1 N2 Base Column HSS Pipe A500 Gr.C RND Typical 2 M2 N2 N3 Support Post Column SquareTube A500 Gr.B RECT Typical 3 M3 N4 N5 Support Post Column SquareTube A500 Gr.B RECT Typical 4 M4 N6 N4 Base Column HSS Pipe A500 Gr.C RND Typical 5 M6 N7 N5 Outrigger Beam Rectangular Tubes 6061-T6 Typical 6 M7 N5 N8 Outrigger Beam Rectangular Tubes 6061-T6 Typical Node Loads and Enforced Displacements (BLC 1 : Vert) Node Label L, D, M Direction Magnitude [(k, k-ft), (in, rad), (k*s²/ft, k*s²*ft)] 1 N8 L Z -1 Node Loads and Enforced Displacements (BLC 2 : Horiz X) Node Label L, D, M Direction Magnitude [(k, k-ft), (in, rad), (k*s²/ft, k*s²*ft)] 1 N8 L X 0.175 Node Loads and Enforced Displacements (BLC 3 : Horiz Y) Node Label L, D, M Direction Magnitude [(k, k-ft), (in, rad), (k*s²/ft, k*s²*ft)] 1 N8 L Y 0.175 Basic Load Cases BLC Description Category Z Gravity Nodal 1 Vert None 1 2 Horiz X None 1 3 Horiz Y None 1 4 DL DL -1 Load Combinations Description Solve P-Delta BLC Factor BLC Factor BLC Factor BLC Factor 1 Vertical Load Yes Y 1 4 DL 1 2 Vertical w/ Y Yes Y 1 4 3 4 DL 1 3 Vertical w/ X Yes Y 1 4 2 4 DL 1 4 Vertical w/ 0.71*(X & Y)Yes Y 1 4 2 2.83 3 2.83 DL 1 5 Working Load 1 Yes Y 1 1 2 0.71 DL 1 3 0.71 6 Working Load 2 Yes Y 1 1 2 1 DL 1 7 Working Load 3 Yes Y 1 1 3 1 DL 1 Load Combination Design Description Service Hot Rolled Cold Formed Wood Concrete Masonry Aluminum Stainless Connection 1 Vertical Load Yes Yes Yes Yes Yes Yes Yes Yes 2 Vertical w/ Y Yes Yes Yes Yes Yes Yes Yes Yes 3 Vertical w/ X Yes Yes Yes Yes Yes Yes Yes Yes 4 Vertical w/ 0.71*(X & Y)Yes Yes Yes Yes Yes Yes Yes Yes 5 Working Load 1 Yes Yes Yes Yes Yes Yes Yes Yes Yes 6 Working Load 2 Yes Yes Yes Yes Yes Yes Yes Yes Yes 7 Working Load 3 Yes Yes Yes Yes Yes Yes Yes Yes Yes 55662 28 Company Designer Job Number Model Name : : : : Diversified Fall Protection M. Boulant 40342 Fixed Outriggers Checked By : __________ 4/18/2023 3:24:30 PM RISA-3D Version 20 [ Fixed Outrigger Template.r3d ]Page 3 Envelope Node Reactions Node Label X [k] LC Y [k] LC Z [k] LC MX [k-ft] LC MY [k-ft] LC MZ [k-ft] LC 1 N1 max 0 6 -0.059 6 -0.663 6 1.261 2 0.001 6 0.959 3 2 min -0.024 3 -0.738 2 -3.115 2 -0.632 3 -0.141 3 0 1 3 N6 max 0 7 0.213 1 7.326 2 -0.071 7 0 7 1.965 3 4 min -0.676 3 0.011 7 1.875 6 -1.536 3 -4.867 3 0 1 5 N5 max NC NC NC NC LOCKED NC 6 min NC NC NC NC LOCKED NC 7 Totals:max 0 7 0 6 4.212 2 8 min -0.7 3 -0.7 2 1.212 5 Envelope Member End Reactions MemberMember End Axial[k] LC y Shear[k] LC z Shear[k] LC Torque[k-ft] LC y-y Moment[k-ft] LC z-z Moment[k-ft] LC 1 M1 I max -0.663 6 0.735 2 0 6 0.959 3 0.141 3 1.261 2 2 min -3.115 2 0.059 6 -0.023 3 0 1 -0.001 6 -0.632 3 3 J max -0.682 6 0.735 2 0 6 0.959 3 0.1 3 -0.008 7 4 min -3.134 2 0.059 6 -0.023 3 0 1 -0.001 6 -1.011 3 5 M2 I max -0.682 6 0.743 2 0 6 0.959 3 0.1 3 -0.008 7 6 min -3.134 2 0.06 6 -0.022 3 0 1 -0.001 6 -1.011 3 7 J max -0.738 6 0.743 2 0 6 0.959 3 0 7 -0.519 6 8 min -3.189 2 0.06 6 -0.022 3 0 1 0 1 -3.369 2 9 M3 I max 7.308 2 -0.012 7 0 7 1.965 3 3.611 3 -0.052 7 10 min 1.856 6 -0.253 3 -0.803 3 0 1 0 1 -1.14 3 11 J max 7.252 2 -0.012 7 0 7 1.965 3 0 7 0 7 12 min 1.8 6 -0.253 3 -0.803 3 0 1 0 1 0 1 13 M4 I max 7.326 2 -0.011 7 0 7 1.965 3 4.867 3 -0.071 7 14 min 1.875 6 -0.226 1 -0.717 3 0 1 0 1 -1.536 3 15 J max 7.308 2 -0.011 7 0 7 1.965 3 3.611 3 -0.052 7 16 min 1.856 6 -0.226 1 -0.717 3 0 1 0 1 -1.14 3 17 M6 I max 0 7 0 7 0 7 0 7 0 7 0 7 18 min 0 1 0 1 0 1 0 1 0 1 0 1 19 J max -0.059 6 -0.777 6 0 6 0 7 0.835 3 16.046 3 20 min -0.738 2 -3.229 2 -0.021 3 0 1 0 1 4.037 7 21 M7 I max 0 6 4.023 3 0 7 0 7 2.8 3 16.046 3 22 min -0.7 2 1.021 7 -0.7 3 0 1 0 1 4.037 7 23 J max 0 6 4 3 0 7 0 7 0 7 0 7 24 min -0.7 2 0.998 7 -0.7 3 0 1 0 1 0 1 Envelope AISC 15TH (360-16): LRFD Member Steel Code Checks Member Shape Code CheckLoc[ft]LCShear CheckLoc[ft]DirLCphi*Pnc [k]phi*Pnt [k]phi*Mn y-y [k-ft]phi*Mn z-z [k-ft]Cb Eqn 1 M1 HSS4.500X0.237 0.103 0 2 0.083 1.75 3 120.969 122.544 13.904 13.904 1 H1-1b 2 M2 HSS4X4X4 0.22 4.5 2 0.076 4.5 y 3 128.181 139.518 16.181 16.181 1.659H1-1b 3 M3 HSS4X4X4 0.321 0 3 0.165 4.5 z 3 128.181 139.518 16.181 16.181 1.667H1-1b 4 M4 HSS4.500X0.237 0.397 0 3 0.178 1.75 3 120.969 122.544 13.904 13.904 1 H1-1b Envelope AA ADM1-15: LRFD - BUILDING Member Aluminum Code Checks Member Shape Code CheckLoc[ft]LCShear CheckLoc[ft]DirLCphi*Pnc[k]phi*Pnt[k]phi*Mny[k-ft]phi*Mnz[k-ft]phi*Vny[k]phi*Vnz[k]Cb Eqn 1 M6 RT4X6X0.25 0.832 7 3 0.068 7 y 2 96.991 149.625 16.08 20.563 47.25 29.25 1 H.1-1 2 M7 RT4X6X0.25 0.954 0 3 0.085 0 y 3 132.925 149.625 16.08 20.563 47.25 29.25 1.668H.1-1 Design Base Connections Max Moment in Outrigger Shear at top of Base Max. Compression Force in Base Max. Tension Force in Base Code checks all below 1.0 Tie-Back Anchor Loading Governs 55662 29