HomeMy WebLinkAbout444 E Huntington Dr - 2024 -444 E. HUNTINGTON DR, ARCADIA, CA 91006
SYMBOLS
BUILDING DEPARTMENT NOTES
FIRE DEPARTMENT NOTES
PROJECT DIRECTORY SHEET INDEXABBREVIATIONS
VICINITY MAP
BUILDING SUMMARY/SCOPE OF WORK
PROJECT SITE
ARCHITECTURAL DRAWINGSEXISTING BUILDING INFORMATION
CONSTRUCTION TYPE:
NUMBER OF FLOORS:
SPRINKLERED:
OCCUPANCY TYPE:
II-B
4
EXISTING SPRINKLERED
EXISTING 'B' TO REMAIN
id1.0 DEMOLITION PLAN
id1.1 NOT USED
id2.0 PARTITION/PROPOSED PLAN
id2.1 REFLECTED CEILING PLAN
id2.2 POWER AND SIGNAL PLAN
id3.0 NOT USED
id4.0 INTERIOR ELEVATIONS
id5.0 PARTITION CONSTRUCTION DETAILS
id5.2 CEILING CONSTRUCTION DETAILS
id6.0 MILLWORK DETAILS
ADJUSTABLE
ACOUSTICAL
ACOUSTICAL
ABOVE FINISH FLOOR
ARCHITECTURAL
BUILDING
BOTTOM
ANODIZED
APPROXIMATE
CONTRACTOR
COLUMN
CONCRETE
CONNECTION
CONTINUOUS
CENTERLINE
DRINKING FOUNTAIN
DIAMETER
DIAMETER
EXISTING
DIMENSION
DRAWING
CORRIDOR
CERAMIC TILE
FINISH FACE
EXPOSED
FLOOR DRAIN
GALVANIZED
FIRE EXTINGUISHER
ALUMINUM
F.F.
GAUGEGA.
GALV.
FT.FOOT
FIN.
FLR.
FINISH
FLOOR
DOORDR.
EQUALEQ.
EXP.
F.D.
F.E.C.
(E)
DWG.
D.F.
Ø
DIA.
DIM.
CORR.
C.T.
DET.DETAIL
BOARDBD.
CONC.
CONN.
CONT.
CONTR.
COL.
CLO.
CLR.
CLOSET
CLEAR
C
CLG.CEILING
BLDG.
BLK.
BOT.
BLOCK
A.F.F.
ANOD.
@
APPROX.
ARCH.
AT
ACOUS.
ALUM.
A.C.T.
ADJ.
SOLID CORE
VINYL COMPOSITIONV.C.T.
WALL COVERINGW.C.
WD.WOOD
W/
W/O WITHOUT
WITH
SCHEDULED
STANDARD
SPECIFICATIONS
STAINLESS STEEL
STRUCTURAL
SUSPENDED
TELEPHONE
TEMPERED GLASS
UNLESS OTHERWISE
STORAGESTOR.
TEMP.GL.
THK.
TYP.
U.O.N.
TYPICAL
THICK
SUSP.
STRUCT.
TELE.
SPECS.
STD.
STL.
S.S.
STEEL
S.C.
SCHED.
SECT.
SIM.
SECTION
SIMILAR
MISC.
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OPPOSITE HAND
OWNER PROVIDE &
RM.
REQ'D.REQUIRED
ROOM
O.P.I.
OPNG.
OPP.
OPENING
O.C.
O.P.C.I.
O/OVER
MTD.
N.I.C.
N.T.S.
MOUNTED
HARDWOOD
GYPSUM BOARD
LAVATORY
MECHANICAL
MANUFACTURER
MISCELLANEOUS
HDWD.
MECH.
MFR.
MIN.
MET./MTL.
MINIMUM
METAL
HT.
LAV.
HEIGHT
GL.
GYP. BD.
GLASS
L
CABINETCAB.
ABANDON(A)
(D)DEMOLISH
CONTRACTOR INSTALL
OWNER PROVIDE &
CABINET
INSTALL
NOTED
TILE
CEILING TILE
F.O.S.FACE OF STUD
MAXIMUMMAX.
MUL.MULLION
R.O.ROUGH OPENING
V.I.F.VERIFY IN FIELD
SPACESP.
(R)RELOCATED
NORTH
APPLICABLE CODES:
STATE BUILDING STANDARDS (CCR, TITLE 24, 2022 EDITION)
PART 2.CALIFORNIA BUILDING CODE W/ CITY AMMENDMENTS
PART 3.CALIFORNIA ELECTRICAL CODE W/ CITY AMMENDMENTS
PART 4.CALIFORNIA MECHANICAL CODE W/ CITY AMMENDMENTS
PART 5.CALIFORNIA PLUMBING CODE W/ CITY AMMENDMENTS
PART 6.CALIFORNIA ENERGY EFFICIENCY STANDARDS W/ CITY AMMENDMENTS
PART 7.CALIFORNIA ELEVATOR SAFETY CONSTRUCTION CODE W/ CITY AMMENDMENTS
PART 8.CALIFORNIA HISTORICAL BUILDING CODE W/ CITY AMMENDMENTS
PART 9.CALIFORNIA FIRE CODE W/ CITY AMMENDMENTS
PART 10 CALIFORNIA CODE FOR BUILDING CONSERVATION W/ CITY AMMENDMENTS
PART 12 CALIFORNIA REFERENCE STANDARDS CODE W/ CITY AMMENDMENTS
id5.1 CONSTRUCTION DETAILS
id0.0 COVER SHEET
id0.1 GENERAL NOTES
id0.2 GENERAL NOTES
id0.4 NOT USED
id0.3 GENERAL ACCESSIBILITY NOTES
1.FIRE LIFE SAFETY AND FIRE PROTECTION WORK SHALL BE PERFORMED ON A DESIGN/BUILD BASIS
UNDER SEPARATE PERMITS.
2.RESPECTIVE CONTRACTORS SHALL BE RESPONSIBLE FOR PLAN CHECK REVIEWS/APPROVALS AND
SECURING APPROPRIATE BUILDING PERMITS.
DESIGN BUILD WORK
1.ALL WORK SHALL CONFORM TO THE 2022 CALIFORNIA BUILDING CODE.
2.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY
WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS,
VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION
SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE
PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.
3.THE FACILITIES INCLUDING, BUT NOT LIMITED TO, SANITARY FACILITIES, DRINKING FOUNTAINS, AND
ELEVATORS ON ALL FLOORS, MUST COMPLY WITH ACCESSIBILITY REQUIREMENTS.
4.TOILET FACILITIES SHALL BE IDENTIFIED BY SIGNAGE IN COMPLIANCE WITH THE INTERNATIONAL SYMBOL OF
ACCESSIBILITY (CBC CHAPTER 11).
5.THE PATH OF TRAVEL FROM THE DESIGNATED HANDICAP PARKING SPACES AND THE PUBLIC SIDEWALK
PROVIDES A FREE AND UNOBSTRUCTED PASSAGE FOR ACCESS TO AND EGRESS FROM THE AREA OF WORK.
6.DOORS SHALL BE NOT LESS THAN 3'-0" IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT.
7.FLOORS OR LANDINGS LOCATED AT A DOORWAY SHALL BE NOT MORE THAN 1/2" LOWER THAN THE TOP OF
THE THRESHOLD, WHICH SHALL HAVE A 1/4" MAXIMUM VERTICAL EDGE AND A CHANGE IN LEVEL NOT
GREATER THAN 1:2.
8.A CLEAR AND LEVEL AREA SHALL BE PROVIDED ON EACH SIDE OF EXIT DOORS WITH A LENGTH OF AT LEAST
60" IN THE DIRECTION OF THE DOOR SWING AND AT LEAST 48" IN THE OPPOSITE DIRECTION, MEASURED AT
RIGHT ANGLES THE DOOR IN ITS CLOSED POSITION.
9.AN APPROVED SEISMIC GAS SHUT OFF VALVE OR EXCESS FLOW SHUT OFF VALVE WILL BE INSTALLED ON THE
FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE
EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING.
SCOPE OF WORK:
TENANT IMPROVEMENT TO EXISTING OFFICE SPACE. EXISTING 'B' OCCUPANCY
TO REMAIN, NO CHANGE OF USE.
EXISTING FLOOR USABLE AREA:7,574 SQ.FT.
SCOPE OF WORK (NEW CONSTRUCTION): 700 SQ.FT.
1.THE CONTRACTOR SHALL SUPPLY AND INSTALL A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS
THAN 2-A OR 2-A10BC WITHIN 75'-0" TRAVEL DISTANCE TO ALL PORTIONS OF THE FLOOR, AND ANY
ADDITIONAL FIRE EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. FIRE EXTINGUISHERS
SHALL ALSO BE PROVIDED DURING CONSTRUCTION.
2.DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION THEREOF SHALL BE
PROVIDED. EXITS, EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS AND EXTINGUISHER LOCATIONS
SHALL NOT BE CONCEALED BY DECORATIVE MATERIAL (CBC CHAPTER 8).
3.INTERIOR WALL AND CEILING FINISHES FOR OFFICES SHALL BE OF CLASS C PER TABLE 803.11AND NOT
EXCEED A FLAME SPREAD INDEX OF 76-200 PER SECTION 803.1.1 OF CBC 2022.
4.INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDORS AND STAIRWELLS SHALL BE OF CLASS B PER
TABLE 803.11 AND NOT EXCEED THE FLAME SPREAD INDEX OF 26-75 PER SECTION 803.1.1 OF CBC 2022.
5.ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME-RETARDANT TREATED IN AN APPROVED
MANNER (CURTAINS, DRAPES, SHADES, ETC.).
6.EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE ENERGIZED FROM SEPARATE
CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES WIRING SYSTEMS. IN THE EVENT
OF THIS SYSTEM'S FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY
SYSTEM. EMERGENCY LIGHTING SHALL GIVE A VALUE OF ONE FOOT-CANDLE AT FLOOR LEVEL (CBC
CHAPTER 10).
7.WHENEVER THE BUILDING IS OCCUPIED, EXIT SIGNS SHALL BE LIT SO THAT THEY ARE CLEARLY VISIBLE.
8.PROVIDE EXIT SIGNS WITH MINIMUM 6" HIGH BLOCK LETTERS WITH 3/4" STROKE ON A CONTRASTING
BACKGROUND. INDICATE THE LOCATION OF EXIT SIGNS ON PLANS (CBC CHAPTER 10).
9.EXIT PATH LIGHTING SHALL BE PROVIDED AT STAIRWAY, HALLWAY, EXIT PASSAGEWAY, AND EGRESS TO A
PUBLIC WAY WHENEVER THE BUILDING IS OCCUPIED, PER CBC CHAPTER 10.
10.EMERGENCY LIGHTING SYSTEM IS REQUIRED AND MUST COMPLY WITH CBC CHAPTER 10.
11.ALL FIRE ALARM DEVICES SHALL BE LOCATED AS NOTED BELOW.
12.ALTERATIONS TO THE FIRE AND LIFE SAFETY SYSTEM SHALL BE UNDER SEPARATE PERMIT FROM THE FIRE
PREVENTION SECTION PLANS. PERMIT APPLICATIONS AND FEES SHALL BE SUBMITTED AND PERMIT APPROVAL
SHALL BE OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK ON THE FIRE AND LIFE SAFETY SYSTEM.
13.PROVIDE AN APPROVED FIRE ALARM SYSTEM WITH A DESCRIPTION OF SEQUENCE OF OPERATION AND LISTED
STATE FIRE MARSHALL APPROVED EQUIPMENT.
14.SUBMIT THREE COMPLETE SETS OF PLANS TO ELECTRICAL DIVISION, DEPARTMENT OF BUILDING AND SAFETY
FOR THE ABOVE REQUIREMENTS, ONE SET DESIGNATED AS THE FIRE DEPARTMENT COPY.
15.PROVIDE AUTOMATIC FIRE EXTINGUISHING SYSTEM THROUGHOUT THE FLOOR. ALTERATIONS TO THE
AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE UNDER SEPARATE PERMIT FROM THE FIRE PREVENTION
SECTION PLANS. PERMIT APPLICATIONS AND FEES SHALL BE SUBMITTED AND PERMIT APPROVAL SHALL BE
OBTAINED PRIOR TO COMMENCEMENT OF ANY WORK ON THE FIRE PROTECTION SYSTEM.
16.SPRINKLER SYSTEM SHALL BE APPROVED BY PLUMBING DIVISION OF LOCAL BUILDING DEPARTMENT PRIOR TO
INSTALLATION (CBC CHAPTER 9).
17.ELEVATOR DOORS SHALL NOT OPEN DIRECTLY INTO ONE-HOUR CORRIDORS (CBC CHAPTER 30).
18.KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE
DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR
STATING "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS".
19.EXIT CORRIDORS, EXTERIOR EXIT BALCONIES, AND AISLES LEADING TO REQUIRED EXITS SHALL HAVE A
MINIMUM WIDTH OF 44" (CBC CHAPTER 10).
20.AN EXIT WALKWAY WITH A MINIMUM WIDTH OF 44" SHALL BE MAINTAINED CONTINUOUSLY TO A PUBLIC
WAY (CBC CHAPTER 10). EXIT PATHS OR WALKWAYS TO PUBLIC WAY SHALL BE CLEARLY DELINEATED BY
PAINTED LINES, RAILINGS, BARRIER POSTS, WALKS, OR OTHER APPROVED MEANS.
21.GLAZING INSTALLED IN ONE-HOUR CORRIDOR MUST BE 1/2" WIRED GLASS IN STEEL FRAMES AND SHALL
NOT EXCEED 25% OF CORRIDOR/ROOM COMMON WALL.
22.FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE HVAC DUCTS PENETRATE FIRE-RATED WALLS OR
CEILINGS.
id0.5 EXISTING SITEPLAN/ P.O.T. (FOR INFORMATION ONLY)
id0.7 OCCUPANCY/EGRESS PLAN
id0.6 EXISTING RESTROOMS (FOR INFORMATION ONLY)
MAD STUDIOMAD
-
-
-
-
-
-
ROOM DESIGNATION
ELEVATION NUMBER
1
ROOM NAME
No.
CEILING HEIGHT REFERENCE
KEY NOTE
ELEVATION REFERENCE
SHEET NUMBER
DETAIL NUMBER
DETAIL REFERENCE
SHEET NUMBER
SECTION NUMBER
SECTION REFERENCE
SHEET NUMBER
DETAIL NUMBER
PLAN DETAIL REFERENCE
SHEET NUMBER
ALIGNMENT OF NEW AND EXISTING ELEMENTS
SURFACE MATERIAL REFERENCE
FIXTURE REFERENCE
EQUIPMENT REFERENCE
WALL FINISH SPECIFICATION
BASE MATERIAL SPECIFICTION
WALL/BASE FINISH REFERENCE
FLOOR FINISH REFERENCE
FLOOR FINISH DIRECTION
FLOOR FINISH TRANSITIONFINFIN
HEIGHT
MATERIAL
MAT
NUM
NUM
MAT
NUM
CLIENT:WELLS FARGO
-
-
-
EMAIL: -
GENERAL CONTRACTOR:CLUNE CONSTRUCTION
IRVING CALDERON
725 S. FIGUEROA ST., STE 300
LOS ANGELES, CA 90017
PHONE: 213.457.7016
EMAIL: icalderon@clunegc.com
DESIGN FIRM:MAD STUDIO
ED MELGAR
670 GLENMORE BLVD.
GLENDALE, CALIFORNIA 91206
EMAIL: ed@madstudiola.com
PHONE: 818.795.3900
WELLS FARGO
ARCADIA HUNTINGTON
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024
ID0.0
COVER SHEET
2
2
2
2
GENERAL CONDITION NOTES
1.THESE DRAWINGS, NOTES, AND SCHEDULES CONVEY THE DESIGN INTENT. THE HIGHEST POSSIBLE QUALITY
OF WORKMANSHIP, MATERIAL, AND EQUIPMENT SHALL BE USED.
2.THESE DOCUMENTS INCORPORATE THE AIA GENERAL CONDITIONS OF THE CONTRACT FOR
CONSTRUCTION (AIA DOCUMENT A201 2017) AND SUPPLEMENTAL CONDITIONS PREPARED BY MAD, IF ANY,
BY REFERENCE. BIDDERS ARE REQUIRED TO BECOME FAMILIAR WITH THESE DOCUMENTS, WHICH CAN BE
OBTAINED FROM MAD.
3.THE BUILDING SHALL COMPLY WITH CBC CHAPTER 11B ACCESSIBILITY REQUIREMENTS AT ENTRANCE, PATH
OF TRAVEL TO AREA OF WORK, AND ANY REVISIONS OR ADDITIONAL WORK REQUIRED BY THE TENANT, FIELD
CONDITIONS, OR LOCAL GOVERNING AUTHORITIES SHALL BE BROUGHT TO THE ATTENTION OF THE
OWNER AND MAD BEFORE PROCEEDING, REGARDLESS OF COST, TIME, OR MATERIAL INCREASE.
4.ALL WORK PERFORMED BY THE CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF MUNICIPAL,
LOCAL OR FEDERAL AND STATE LAWS AS WELL AS ANY OTHER GOVERNING REQUIREMENTS, WHETHER OR
NOT SPECIFIED ON THE DRAWINGS.
5.CONTRACTOR SHALL ENSURE THAT INSTALLATION METHODS CONFORM TO ALL BUILDING CODE
REQUIREMENTS. THE MATERIALS SPECIFIED ARE INTENDED TO MEET CODE REQUIREMENTS. ANY
DISCREPANCY BETWEEN THE CONSTRUCTION DOCUMENTS AND CODE REQUIREMENTS SHALL BE BROUGHT
TO THE ATTENTION OF MAD IMMEDIATELY BY THE CONTRACTOR, AND PRIOR TO PERFORMANCE OF
SPECIFIED WORK.
6.WHERE THE CONTRACT DOCUMENTS CALL FOR ANY WORK OF A MORE STRINGENT NATURE THAN THAT
REQUIRED BY THE BUILDING CODE OR ANY OTHER DEPARTMENT HAVING JURISDICTION OVER THE WORK,
THE WORK OF THE MOST STRINGENT NATURE CALLED FOR BY THE CONTRACT, CONSTRUCTION NOTES, OR
DRAWINGS SHALL BE FURNISHED IN ALL CASES.
7.ALL WORK LISTED, SHOWN, OR IMPLIED ON ANY CONSTRUCTION DOCUMENT SHALL BE SUPPLIED AND
INSTALLED BY THE CONTRACTOR, UNLESS SPECIFICALLY NOTED "NOT IN CONTRACT".
8.THE CONTRACTOR SHALL SUBMIT A DETAILED CONSTRUCTION SCHEDULE TO THE OWNER INDICATING
PHASING OF WORK FROM START TO FINISH OF THE PROJECT.
9.INSURANCE AND BONDING FOR THE PROJECT SHALL BE AS DIRECTED BY AND TO THE SATISFACTION OF THE
OWNER.
10.THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LEGALLY REQUIRED APPROVALS AND PERMITS NECESSARY
FOR THE EXECUTION AND COMPLETION OF HIS WORK AND SHALL FORWARD COPIES OF EXECUTED PERMITS
TO MAD AND TO LANDLORD.
11.ALL MAD DRAWINGS AND ALL CONSTRUCTION NOTES ARE COMPLEMENTARY, AND WHAT IS CALLED FOR BY
EITHER WILL BE BINDING AS IF CALLED FOR BY ALL. ANY WORK SHOWN OR REFERRED TO ON ANY ONE SET
OF DRAWINGS SHALL BE PROVIDED AS THOUGH SHOWN ON ALL RELATED DRAWINGS.
12.THE CONTRACTOR IS WHOLLY RESPONSIBLE FOR THE COORDINATION AND SCHEDULING OF THE WORK
FOR ALL SUBCONTRACTORS, CRAFTSMEN, AND TRADESMEN REQUIRED TO COMPLETE THE JOB.
13.THE CONTRACTOR SHALL NOTIFY MAD IMMEDIATELY IF HE CANNOT COMPLY WITH ALL REQUIREMENTS
CALLED FOR ON THESE DRAWINGS.
14.THE CONTRACTOR SHALL NOTIFY MAD IMMEDIATELY OF ANY DISCREPANCIES OR OMISSIONS BETWEEN THE
DRAWINGS, THESE NOTES, AND FIELD CONDITIONS, AND REQUEST CLARIFICATION BEFORE COMMENCING
ANY WORK.
15.BY ENTERING INTO AN AGREEMENT WITH THE OWNER, THE CONTRACTOR REPRESENTS THAT HE HAS VISITED
THE JOB SITE, FAMILIARIZED THEMSELVES WITH EXISTING CONDITIONS, AND NOTED ANY DISCREPANCIES
WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
16.DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALLER SCALE
DETAILS.
17.ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION
STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR DEFINITION, MAD SHALL BE NOTIFIED
FOR CLARIFICATION.
18.CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE RELATING TO THE
WORK OF EACH TRADE. NO ALLOWANCE SHALL BE MADE FOR ANY EXTRA EXPENSE OR EXTENSION OF TIME
DUE TO CONTRACTOR'S FAILURE OR NEGLIGENCE IN COMPLETELY EXAMINING THE JOB SITE.
19.CONTRACTOR SHALL CONTACT BUILDING MANAGEMENT TO DETERMINE THE BUILDING OWNER'S RULES
FOR CONSTRUCTION, DELIVERIES, CONSTRUCTION TASKS TO BE PERFORMED OUTSIDE REGULAR BUSINESS
HOURS ONLY, AND ANY OTHER SPECIAL BUILDING REQUIREMENTS WHICH WILL AFFECT THE WORK. IF
OVERTIME WORK IS REQUIRED BY ANY TRADE, APPROVAL (INCLUDING COST APPROVAL) MUST BE OBTAINED
PRIOR TO THE EXECUTION OF ANY WORK. THE GENERAL INTENT IS THAT ALL WORK EXCEPT FOR
NOISE-GENERATING CONSTRUCTION SHALL BE PERFORMED ON REGULAR TIME.
20.THE GENERAL CONTRACTOR, SUBCONTRACTORS, AND ANY OTHER CONTRACTOR INVOLVED IN THIS
PROJECT SHALL TAKE NOTE THAT ANY COSTS DUE TO DEFECTIVE AND/OR ILL-TIMED WORK AS A RESULT OF,
BUT NOT LIMITED TO, INFERIOR WORKMANSHIP OR MATERIALS AND/OR IMPROPER SCHEDULING OR
DELINQUENT ORDERING, SHALL BE BORNE BY THE PARTY RESPONSIBLE.
21.THE GENERAL CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS FROM HIS OWN AND HIS
SUBCONTRACTORS' WORK, CARPET AND TELECOMS INSTALLATION, ETC., AND PROVIDE FOR ITS REMOVAL
FROM THE JOB SITE.
22.THE CONTRACTOR SHALL EXERCISE STRICT DUST CONTAINMENT CONTROL TO PREVENT DIRT OR DUST FROM
LEAVING THE JOB SITE.
23.THE CONTRACTOR SHALL PROVIDE PROTECTION DURING SITE WORK, DEMOLITION, AND CONSTRUCTION.
THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING
CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING CONSTRUCTION, STRUCTURE, OR EQUIPMENT
SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER, AT THE EXPENSE OF THE
CONTRACTOR.
24.THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON
SITE DURING ALL CONSTRUCTION PHASES FOR THE USE OF ALL TRADES. THE CONTRACTOR SHALL SEE THAT
ALL SUBCONTRACTORS RECEIVE COMPLETE SETS OF CONSTRUCTION DRAWINGS, OR ASSUME FULL
RESPONSIBILITY FOR COORDINATION OF WORK WHEN COMPLETE SETS ARE NOT AVAILABLE TO
SUBCONTRACTORS.
25.ALL EXISTING MANUFACTURED ITEMS NOT BEING REMOVED SHALL BE REFURBISHED AS REQUIRED, ANY
LOOSE ITEMS TIGHTENED (INCLUDING, BUT NOT LIMITED TO, EXIT SIGNS, DOWNLIGHTS, SPEAKERS,
MOLDINGS, ETC.), AND ANY MISSING PARTS REPLACED BY THE CONTRACTOR TO ACHIEVE A COMPLETE
INSTALLATION WITH A NEW APPEARANCE.
26.ALL REQUIRED EXITS, WAYS OF APPROACH THERETO, AND WAYS OF TRAVEL FROM THE EXIT INTO THE STREET
SHALL CONTINUOUSLY BE MAINTAINED FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS FOR EGRESS IN
CASE OF FIRE OR OTHER EMERGENCY.
27.DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL EXISTING EXIT SIGNS, EXIT
LIGHTING, FIRE PROTECTION DEVICES AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
28.THE CONTRACTOR SHALL VERIFY SIZE, LOCATION, ELECTRICAL REQUIREMENTS, AND CHARACTERISTICS OF
ALL WORK AND/OR EQUIPMENT SUPPLIED BY THE OWNER OR OTHERS PRIOR TO THE START OF RELATED
WORK WITH THE MANUFACTURER OR SUPPLIER.
29.MANUFACTURER'S NAME, TRADEMARK, LOGOS, ETC., SHALL NOT BE VISIBLE TO THE PUBLIC.
30.THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY
ALTERING, ADDING TO, OR DEDUCTING FROM THE WORK. THE CONTRACT SUM AND CLAIMS FOR
EXTENSION OF TIME SHALL BE ADJUSTED ACCORDINGLY. SUCH WORK SHALL BE OTHERWISE EXECUTED
UNDER THE CONDITIONS OF THE ORIGINAL CONTRACT.
31.ALL "EXISTING TO REMAIN", "EXISTING TO BE RELOCATED", AND/OR NEW ITEMS INSTALLED BY THE
CONTRACTOR, IN ADDITION TO BEING AMPLY PROTECTED THROUGHOUT THE PERIOD OF CONSTRUCTION,
SHALL BE THOROUGHLY CLEANED TO THE SATISFACTION OF MAD PRIOR TO BEING TURNED OVER TO THE
OWNER.
32.THE CONTRACTOR AGREES TO PAY ALL TRANSPORTATION CHARGES ON ALL MATERIAL AND EQUIPMENT TO
THE POINT OF USE AND SHALL BE RESPONSIBLE FOR ALL UNLOADING, CHECKING, AND STORING OF SAME
IN CONNECTION WITH THIS CONTRACT.
33.IF THE CONTRACTOR CLAIMS THAT ANY REVISION TO THE DRAWINGS INVOLVES EXTRA COST UNDER THIS
CONTRACT, HE SHALL GIVE WRITTEN NOTICE TO MAD WITHIN A REASONABLE TIME AFTER RECEIPT OF SUCH
INSTRUCTIONS AND IN ANY EVENT, BEFORE PROCEEDING TO EXECUTE THE WORK. THE PROCEDURE SHALL
THEN BE AS PROVIDED FOR IN THE AGREEMENT UNDER "CHANGES IN THE WORK". NO SUCH CLAIMS SHALL
BE VALID UNLESS SO MADE. UNLESS OTHERWISE AGREED, NO PAYMENT ON SUCH BILLS WILL BE MADE UNTIL
FINAL SETTLEMENT.
34.ALL CLAIMS FOR ADDITIONAL WORK WILL BE SUBMITTED IN WRITING FOR REVIEW BY MAD AND SHALL
INCLUDE A COMPLETE DESCRIPTION OF THE WORK, MATERIALS USED, ROOM NUMBER OF THE AREA OF
WORK, AND AUTHORIZATION UNDER WHICH THE WORK IS BEING PERFORMED. TOTAL COST OF THE WORK,
INCLUDING THE CONTRACTOR'S MARK-UP, SHALL BE INCLUDED IN THE SUBMITTAL.
35.THE CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING HANGERS, OR OTHER SUPPORT FOR ALL
FIXTURES, EQUIPMENT, CABINETRY, FURNISHINGS, AND ALL OTHER ITEMS AS REQUIRED.
36.MAXIMUM ROOM OCCUPANT LOAD SIGNS SHALL BE FURNISHED AND INSTALLED AS REQUIRED BY THE LOCAL
GOVERNING BUILDING CODE.
37.AT THE TIME OF BID SUBMITTAL, THE CONTRACTOR SHALL ADVISE MAD, IN WRITING, OF ANY SPECIFIED
MATERIALS OR EQUIPMENT WHICH ARE EITHER UNAVAILABLE OR WILL CAUSE A DELAY IN THE COMPLETION
OF CONSTRUCTION.
38.THE CONTRACTOR SHALL PROVIDE AND INSTALL ROUGH PLUMBING AND FINAL HOOK-UP FOR ALL SPECIFIED
FIXTURES AND APPLIANCES AND SHALL SUPPLY ALL SUCH FIXTURES AND APPLIANCES, U.O.N.
39.PRIOR TO INSTALLATION OF CARPET AND WINDOW COVERING, THE CONTRACTOR SHALL MAINTAIN THE
SPACE IN BROOM CLEAN CONDITION WHETHER OR NOT SUCH INSTALLATION IS THE CONTRACTOR'S
RESPONSIBILITY.
40.THE CONTRACTOR SHALL PROVIDE ALLOWANCE FOR APPLIANCES, U.O.N.
41.THE CONTRACTOR SHALL LEAVE THE BUILDING IN A LOCKABLE CONDITION DURING THE PERIOD OF THIS
WORK WHEN THE CONTRACTOR'S WORKMEN ARE NOT PRESENT AT THE JOB SITE.
42.THE CONTRACTOR SHALL DEACTIVATE ALL UTILITY LINES IN CONTRACT AREA PRIOR TO START OF WORK AS
NECESSARY, AFTER SECURING OWNER'S PERMISSION.
43.THE CONTRACTOR SHALL PATCH, REPAIR, REPLACE, AND/OR REFINISH EXISTING CONSTRUCTION AS
NECESSARY TO REFURBISH THE AREA OF WORK.
44.ANY AND ALL PROPOSED REVISIONS SHALL BE SUBMITTED IN THE FORM OF A WRITTEN CHANGE ORDER TO
BE APPROVED AND AUTHORIZED BY MAD AND THE OWNER PRIOR TO START OF PROPOSED WORK.
45.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LIFE SAFETY EQUIPMENT AS REQUIRED BY
STATE AND LOCAL BUILDING CODES.
46.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF THE FIRE SPRINKLER
CONTRACTOR, WHO SHALL DESIGN AND PROVIDE CERTIFIED SPRINKLER DRAWINGS FOR MAD'S APPROVAL.
47.THE CONTRACTOR SHALL HOLD HARMLESS THE TENANT, BUILDING OWNER, MAD, AND THEIR
REPRESENTATIVES OF ANY LEGAL ACTION ARISING AS A RESULT OF THE CONTRACTOR'S WORK.
48.DAMAGE TO WORK SHALL BE REPAIRED BY THE TRADE WHOSE WORK IS DAMAGED AND CHARGED TO THE
PARTY RESPONSIBLE FOR THE DAMAGE.
49.THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR CUTOUTS AND PATCHING REQUIRED FOR
INSTALLATION OF ALL WORK.
50.CONTRACTOR TO INFORM MAD WHEN CHALKLINE LAYOUT OF PARTITIONS IS COMPLETED SO THAT IT CAN
BE VERIFIED AND ANY REQUIRED CHANGES MADE PRIOR TO CONSTRUCTION.
51.ALL PLUMBING FIXTURES SHALL BE SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR. GENERAL
CONTRACTOR SHALL COORDINATE SUPPLY OF ALL NECESSARY INFORMATION ON REQUIRED CUTOUTS TO
MILLWORK CONTRACTOR.
52.ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE
ACCEPTANCE OF THE PROJECT BY THE OWNER, UNLESS STATED OTHERWISE.
53.CONTRACTOR SHALL PROVIDE SUBMITALS AS ELECTRONIC FILE (PDF PREFERRED, OR U.O.N.) TO MAD FOR
DESIGN APPROVAL AFTER HE HAS REVIEWED THEM FOR CONSTRUCTIBILITY, COORDINATION BETWEEN
TRADES, AND CONFORMANCE WITH THE CONTRACT DOCUMENTS.
54.THE CONTRACTOR SHALL SUBMIT (3) SAMPLES OF FINISH MATERIALS, FIXTURES AND EQUIPMENT TO MAD FOR
APPROVAL PRIOR TO INSTALLATION. THE CONTRACTOR SHALL BE WHOLLY LIABLE IF HE FAILS TO DO SO,
WHETHER MATERIALS ARE SPECIFIED CORRECTLY OR INCORRECTLY IN THE CONTRACT DOCUMENTS.
55.PROVIDE LIST OF ALL SUBMITTALS WITH SCHEDULE FOR TIMELY REVIEW OR RE-SELECTION IF REQUIRED. A
MINIMUM OF ONE (1) WEEK TIME FRAME FOR REVIEW OF ANY SUBMITTAL IS REQUIRED, UNLESS
ARRANGEMENTS FOR EXPEDITED REVIEW WITH MAD IS ACCEPTED.
56.GC SHALL SUBMIT THE LIGHTING PACKAGE TO MAD FOR REVIEW WITHIN THE FIRST TWO WEEKS AFTER
CONTRACT HAS BEEN AWARDED TO ENSURE SUFFICIENT TIME FOR REVIEW. A MINIMUM OF ONE (1) WEEK
TIME FRAME FOR REVIEW OF LIGHTING PACKAGE SUBMITTAL IS REQUIRED, UNLESS ARRANGEMENTS FOR
EXPEDITED REVIEW WITH MAD IS ACCEPTED.
57.BEFORE ACCEPTANCE BY THE OWNER, THE COMPLETED CONSTRUCTION SHALL BE CLEANED, LABELS
REMOVED, AND ALL OTHER TOUCH UP COMPLETED.
58.CONTRACT CLOSE-OUT SHALL OCCUR ONLY AFTER MAD HAS PREPARED THE CERTIFICATE OF SUBSTANTIAL
COMPLETION AND PUNCH LIST, AND PUNCH LIST ITEMS HAVE BEEN CORRECTED. THE CONTRACTOR SHALL
SUBMIT MAINTENANCE AND WARRANTY MANUALS, RELEASE OF LIENS, AND RECORD DRAWINGS TO MAD
WITH HIS FINAL APPLICATION FOR PAYMENT. MAD SHALL PREPARE ANY NECESSARY CHANGE ORDERS
REQUIRED TO FINALIZE THE COST OF THE PROJECT BASED ON THE CONTRACTOR'S FINAL SUBMITTALS.
GENERAL PARTITION NOTES
1.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL PARTITIONS INDICATED ON THE DRAWINGS.
2.VERIFY ALIGNMENTS IN FIELD. NOTIFY MAD IMMEDIATELY IF MISALIGNMENT OF EXISTING ELEMENTS SHOULD
OCCUR.
3.THE CONTRACTOR SHALL USE CORNER BEADS AT ALL EXPOSED CORNERS AND EXPOSED ENDS IN PLASTER
AND DRYWALL PARTITIONS.
4.ALL PARTITIONS SHALL BE ANCHORED PER MANUFACTURERS' SPECIFICATIONS AND AS REQUIRED BY
APPLICABLE BUILDING CODES.
5.BRING TO THE ATTENTION OF MAD ANY FIELD CONDITIONS THAT DO NOT ALLOW CONSTRUCTION OR
INSTALLATION AS DRAWN.
6.NOTE ANY BASE BUILDING DEFICIENCIES BEFORE THE START OF CONSTRUCTION TO MAD.
7.MAD SHALL HAVE THE RIGHT TO REVIEW AND APPROVE CHALK LINES PRIOR TO INSTALLATION OF TRACKS.
MAD SHALL BE NOTIFIED OF ANY DEVIATION FROM DIMENSIONS OR CLEARANCES INDICATED ON PLANS
REQUIRED DUE TO FIELD CONDITION.
8.THE CONTRACTOR SHALL SUPPLY ALL RETURN AIR OPENINGS IN SLAB TO SLAB PARTITIONS ABOVE CEILINGS
AS REQUIRED BY ENGINEERING DRAWINGS. ALL OPENINGS IN DEMISING AND SOUND-ATTENUATED
PARTITIONS SHALL HAVE SOUND BOOTS AND ALL OPENINGS IN FIRE-RATED PARTITIONS SHALL HAVE FIRE
DAMPERS AS REQUIRED BY LOCAL BUILDING CODES. CONTRACTOR SHALL COORDINATE WITH
ENGINEERING DRAWINGS AND INFORM MAD OF DISCREPANCIES PRIOR TO BIDDING.
9.THE CONTRACTOR SHALL PROVIDE SUFFICIENT FRAMING IN PARTITIONS TO ACCOMMODATE ALL DUCT
WORK. RETURN AIR OPENINGS AND GRILLS ABOVE AND BELOW CEILINGS SHALL BE COORDINATED WITH
MECHANICAL ENGINEERING DRAWINGS AND MECHANICAL CONTRACTOR'S SHOP DRAWINGS. ALL
OPENINGS SHALL BE PROPERLY SEALED FOR SOUNDPROOFING AND AGAINST VIBRATION.
10.THE CONTRACTOR SHALL PROVIDE AND INSTALL ACCESS PANELS AS REQUIRED FOR MECHANICAL,
ELECTRICAL, AND PLUMBING INSTALLATIONS PER APPLICABLE BUILDING CODES. CONTRACTOR SHALL
COORDINATE TYPE AND LOCATION OF ACCESS PANELS WITH MAD PRIOR TO INSTALLATION.
11.THE GENERAL CONTRACTOR SHALL COORDINATE ALL PLUMBING ROUGH-INS, FIXTURES AND ACCESSORIES
INDICATED IN THE DRAWINGS.
12.THE GENERAL CONTRACTOR SHALL COORDINATE ALL VALVES AS INDICATED IN THE DRAWINGS AND/OR AS
REQUIRED FOR THE PROPER CONTROL OF THE PIPING AND APPARATUS INSTALLED AS PART OF THIS PROJECT
SO THAT ANY FIXTURE, LINE OR APPARATUS MAY BE CUT OFF AND REPAIRED WITHOUT INTERFERENCE OR
INTERRUPTION OF SERVICE TO THE REMAINDER OF THE BUILDING.
13.ALL PIPING SHALL BE TESTED AND INSPECTED AS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION,
BEFORE CLOSING OR CONCEALING IN PARTITIONS.
14.GENERAL CONTRACTOR SHALL COORDINATE WITH MILLWORK CONTRACTOR/FURNITURE MANUFACTURER
FOR EXACT STUD LOCATIONS AND HEIGHTS OF MILLWORK AND FURNITURE BACKING PRIOR TO
INSTALLATION OF GYPSUM BOARD.
15.IF OUTLETS ARE INSTALLED DIRECTLY INTO CORE WALLS, SEAL/INSULATE AS REQUIRED PER CODES TO
MAINTAIN THE INTEGRITY OF WALL RATING. REFER TO POWER AND SIGNAL PLAN FOR LOCATIONS.
16.PATCH/REPAIR ALL EXISTING TO REMAIN PARTITIONS, TO RECEIVE A NEW FINISH.
17.INSTALL FIRE DAMPERS IN ALL DUCTS PENETRATING RATED CORRIDOR WALLS AND/OR CEILINGS. DAMPERS
ARE TO COMPLY WITH LOCAL MUNICIPAL CODES.
18.IN SOUND RATED ROOMS, ALL WALL AND FLOOR PENETRATIONS FOR PIPES, DUCTS AND OUTLETS SHALL BE
SEALED WITH AN ACOUSTICAL SEALANT AND CONCEALED OR RECESSED FIXTURES SHALL BE COVERED OR
BACKED WITH A SOUND ATTENUATION BLANKET.
19.PROVIDE WATER RESISTANT GYPSUM BOARD IN ALL TOILETS AND SHOWER ROOMS.
20.INSTALL COMBINATION FIRE/SMOKE DAMPERS AT ALL DUCTS PENETRATING RATED CORRIDOR WALL(S)
AND/OR CEILING(S). DAMPERS SHALL COMPLY WITH CBC CHAPTER 7.
21.THE GENERAL CONTRACTOR SHALL VERIFY THE MANUFACTURER OF ALL EXISTING INTERIOR BUILDING
ELEMENTS BUT NOT LIMITED TO DOOR FRAMES, DOORS, DOOR HARDWARE, FIRE EXTINGUISHER CABINETS,
MILLWORK FINISHES, AND MILLWORK HARDWARE.
22.WHEN NEW INTERIOR BUILDING ELEMENTS ARE TO MATCH EXISTING THE GENERAL CONTRACTOR SHALL
SUBMIT SAMPLES OF PROPOSED NEW AND EXISTING ELEMENTS FOR REVIEW AND APPROVAL PRIOR TO
COMMENCEMENT OF INSTALLATION OF SUCH ELEMENTS.
23.GYPSUM BOARD NOTES:
a.ALL GYPSUM BOARD SHEETS TO RUN VERTICALLY.
b.TAPE OUTER JOINTS OF GYPSUM BOARD ONLY.
c.NO JOINTS EXCEPT AT STUDS.
d.DRYWALL SCREW EDGE AND FIELD SPACING PER GYPSUM BOARD MANUFACTURERS' RECOMMENDATIONS.
e.ALL SCREWS SHALL ENGAGE STUDS, MINIMUM CSTC 40-44.
f.FIBERGLASS BATT INSULATION SHALL BE OWENS/CORNING FIBERGLASS NOISE BARRIER BATTS, OCF
FRICTION FIT OR APPROVED EQUAL. FIBERGLASS THICKNESS TO EQUAL STUD DEPTH.
g.STAGGER JOINTS OF GYPSUM BOARD WHERE MULTIPLE LAYERS OCCUR.
h.DO NOT GLUE MULTIPLE LAYERS OF GYPSUM BOARD TOGETHER.
i.NO MECHANICAL TIES BETWEEN OPPOSITE SIDES OF PARTITION.
j.ALL GYPSUM BOARD SHALL BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED ON PLANS.
k.TAPE, BED, AND SAND SMOOTH ALL CORNERS AND JOINTS TO RECEIVE WALL FINISH.
GENERAL POWER & DATA NOTES
1.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LIGHT FIXTURES AND ELECTRICAL WORK AS SHOWN OR
IMPLIED IN DRAWINGS AND NOTES.
2.ALL LIGHT SWITCHES SHALL BE CIRCUITED AND INSTALLED TO COMPLY WITH APPLICABLE LOCAL CODES AND
STATE ENERGY REQUIREMENT.
3.THE MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT
IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK DRAWINGS FOR COORDINATION PRIOR TO BIDDING AND
AGAIN PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL WORK. ANY DISCREPANCY BETWEEN THE
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF MAD FOR CLARIFICATION. WORK INSTALLED IN
CONFLICT WITH MAD'S DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR'S
EXPENSE AND SHALL NOT IMPACT THE SCHEDULE.
4.REFER TO ENGINEERING DRAWINGS FOR CIRCUITING AND EXACT SPECIFICATIONS. MECHANICAL AND
ELECTRICAL ENGINEERS' DRAWINGS ARE NOT INTENDED TO INDICATE EXACT LOCATIONS OF FIXTURES OR
EQUIPMENT. REFER TO MAD'S DRAWINGS FOR LOCATIONS OF FIXTURES, OUTLETS AND EQUIPMENT.
5.VERIFY COMMUNICATIONS REQUIREMENTS AND RACKS, RISERS, CIRCUITING, ETC. WITH APPROPRIATE
CONSULTANT DRAWINGS. PROVIDE BACK BOX WITH BLANK COVER PLATE AND CONDUIT STUB-UP TO
CEILING FOR CARD READERS. VERIFY SIZE AND LOCATION OF BACK BOX AND CONDUIT.
6.GENERAL CONTRACTOR TO COORDINATE ALL NEW SECURITY SYSTEM WORK WITH TENANT'S SECURITY
VENDER & ELECTRICAL ENGINEER DRAWINGS. CONTRACTOR TO PROVIDE ALL CONDUITS AND POWER AS
REQUIRED. CONTRACTOR TO ALSO VERIFY LOCATION OF SECURITY MONITORING SYSTEM PRIOR TO
INSTALLATION. NOTIFY MAD OF ANY CONFLICTS BETWEEN DRAWINGS PRIOR TO ORDERING OR INSTALLING
MATERIALS.
7.REFER TO MAD'S DRAWINGS FOR EXACT SPECIFICATIONS AND LOCATIONS OF FIXTURES, OUTLETS AND
EQUIPMENT.
8.REFER TO ELECTRICAL ENGINEER DRAWINGS FOR ADDITIONAL EQUIPMENT/DEVICE REQUIREMENTS.
9.THE GC SHALL BE RESPONSIBLE FOR VERIFYING THE EQUIPMENT'S ENVIRONMENTAL & ELECTRICAL
REQUIREMENTS.
10.CONTRACTOR SHALL VERIFY QUANTITY AND LOCATION OF EXISTING OUTLETS SHOWN TO REMAIN. ADVISE
MAD OF ANY CONFLICTS PRIOR TO CONSTRUCTION.
11.THE CONTRACTOR SHALL COORDINATE HIS WORK WITH MANUFACTURERS' SPECIFICATIONS AND
REQUIREMENTS.
12.THE WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL
BOARD OF FIRE UNDERWRITERS, PUBLIC UTILITIES COMPANY, OWNER'S AND LANDLORD'S
COMMUNICATIONS COMPANY, AND ALL OTHER AUTHORITIES HAVING JURISDICTION.
13.ALL NEW MATERIALS REQUIRED SHALL CONFORM TO THE STANDARDS OF UNDERWRITERS' LABORATORIES,
INC. IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED, U.O.N.
14.GENERAL CONTRACTOR TO COORDINATE SECURING OF PERMITS FOR LOW VOLTAGE WIRING.
15.GENERAL CONTRACTOR TO COORDINATE SECURING OF PERMITS FOR FIRE/LIFE SAFETY DEVICES.
16.THE CONTRACTOR SHALL FURNISH, INSTALL, AND COORDINATE ANY ELECTRICAL AND/OR LIGHTING ITEMS
WITH CABINET WORK AS REQUIRED, U.O.N.
17.THE CONTRACTOR SHALL COORDINATE ANY COMMUNICATIONS/DATA & AV REQUIREMENTS WITH THE
OWNER'S IT/AV CONTRACTOR AS REQUIRED.
18.THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY ELECTRICAL SERVICE AND LIGHTING FOR ALL TRADES AS
REQUIRED.
19.PROVIDE COMMUNICATIONS/DATA/AV OUTLETS AND ALL NECESSARY CONDUIT RUNS AS SHOWN ON
POWER AND DATA PLANS.
20.PROVIDE SLEEVES IN RATED PARTITIONS ABOVE CEILING FOR COMMUNICATIONS/DATA. VERIFY THE SIZE OF
REQUIRED CONDUITS WITH COMMUNICATIONS/DATA CONTRACTOR AND TENANT PRIOR TO START OF
WORK.
21.ALL POWER, COMMUNICATIONS/DATA, AND AV CONDUIT SHALL BE CONCEALED IN PARTITIONS AND/OR
CEILINGS.
22.PROVIDE METER, METER LOOP, AND SERVICE IN ACCORDANCE WITH LOCAL AND ELECTRICAL RUNS AS THEY
OCCUR.
23.PROVIDE POWER DISTRIBUTION TO ALL LIGHTING AND EQUIPMENT.
24.PROVIDE SERVICE AND CONNECTIONS FOR HVAC EQUIPMENT AND CONTROLS.
25.PROVIDE ALL PANELS, CUTTERS AND DISCONNECTS.
26.PROVIDE PANEL COMPLETE WITH TYPEWRITTEN DIRECTORY AND SPLIT BARS FOR TIME-CONTROLLED
CIRCUITS.
27.COORDINATE CONTROL WIRING WITH HVAC CONTRACTOR.
28.PROVIDE SERVICE, OUTLETS, OR CONNECTION AS REQUIRED FOR FIXTURES AND/OR EQUIPMENT FURNISHED
AND INSTALLED BY OTHERS.
29.ALL NEW COMMUNICATIONS AND/OR DATA CONDUIT SHALL BE 3/4"Ø STUB UP 10" ABOVE PARTITION WITH
90 DEGREE SWEEP TO PLENUM SPACE. PROVIDE PLASTIC BUSHING AT STUB UP CONDUIT.
30.ALL NEW AV CONDUIT SHALL BE 1-1/4"Ø (U.O.N.) STUB UP 10" ABOVE PARTITION WITH 90 DEGREE SWEEP TO
PLENUM SPACE. PROVIDE PLASTIC BUSHING AT STUB UP CONDUIT.
28.ALL VOICE AND DATA WIRING SHALL BE PLENUM RATED. CONTRACTOR SHALL PROVIDE WALL BOX AND
CONDUIT FROM BOX TO CEILING PLENUM. CONDUIT SHALL HAVE PULL STRINGS. COORDINATE WITH
TENANTS VOICE/DATA CONSULTANT.
29.THE MINIMUM SIZE JUNCTION BOX FOR ALL WALL MOUNTED OUTLETS SHALL BE 4S, DEEP. THIS SHALL
INCLUDE, BUT NOT BE LIMITED TO ELECTRICAL, PHONE/DATA, AUDIO/VISUAL AND SECURITY. REFER TO
ELECTRICAL ENGINEER'S DRAWINGS.
30.JUNCTION BOXES AT ALL ACOUSTICAL PARTITION SHALL RECEIVE 'LOWRY' OR APPROVED EQUAL, BOX PADS
(MIN. 1/8" THICK, PERMANENTLY RESILIENT MATERIAL) ALL HOLES IN JUNCTION BOXES SHALL BE COMPLETELY
COVERED WITH PADS, MOLDED AND PRESSED ONTO THE BACK AND SIDES OF BOX.
31.PROVIDE EXTENSION RING AT FIRE ALARM BOXES & WALL OUTLETS ALONG CORE WALLS WHEREVER FURRED
PARTITIONS & FABRIC-WRAPPED/TACKABLE WALL SURFACES OCCUR. REFER TO ELEVATIONS & FINISH PLAN(S)
FOR LOCATIONS OF THESE CONDITIONS.
32.THE GC SHALL SUBMIT, FOR DESIGNER'S APPROVAL, SAMPLES OF ALL SWITCHES, ELEC, COMMUNICATIONS &
DATA OUTLETS & ANY OTHER ELECTRICAL DEVICES THAT ARE TO BE SURFACE-MOUNTED ON THE PROJECT
(INCLUDING SUBCONTRACTOR DEVICES) PRIOR TO INSTALLATION.
33.THE GC SHALL SUBMIT TO MAD FOR APPROVAL, PLANS INDICATING LOCATIONS OF SURFACE-MOUNTED
FIRE/LIFE SAFETY DEVICES, INCLUDING STROBE LIGHTS, PRIOR TO INSTALLATION.
GENERAL DEMOLITION NOTES
1.THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIAL AS REQUIRED TO COMPLETE
DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED ON PLANS OR AS OTHERWISE DIRECTED BY
OWNER/TENANT.
2.THE GENERAL CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE REGULATIONS OF THE BUILDING FOR
DEMOLITION AND REMOVAL OF DEBRIS, INCLUDING OVERTIME WORK REQUIRED.
3.PRIOR TO FINAL BID SUBMITTAL, THE GENERAL CONTRACTOR SHALL VERIFY IF ANY EXISTING PIPING, HVAC OR
ANY OTHER BUILDING SYSTEM COMPONENTS NEED TO BE RELOCATED IN ORDER TO ACCOMMODATE THE
PROPOSED DESIGN. IF SO, SUCH MODIFICATIONS ARE TO BE IDENTIFIED IN THE BID AND PRESENTED TO
THE CLIENT/DESIGNER TO ACCEPT OR REJECT. CHANGE ORDERS FOR THESE KINDS OF MODIFICATIONS
WILL NOT BE ACCEPTED DURING CONSTRUCTION.
4.PRIOR TO FINAL BID SUBMITTAL, THE GENERAL CONTRACTOR SHALL VERIFY IF THE EXISTING CEILING SYSTEM
NEEDS TO BE UPGRADED TO COMPLY WITH LOCAL BUILDING AND SEISMIC CODES. IF SO, THIS SHALL BE
INCLUDED IN THE BID/BASE SCOPE OF WORK. CHANGE ORDERS FOR THIS MODIFICATION WILL NOT BE
ACCEPTED DURING CONSTRUCTION.
5.ALL DEMOLITION AND CONSTRUCTION SHALL BE PERFORMED DURING HOURS DETERMINED BY LANDLORD.
(MAY REQUIRE WORK BE PERFORMED AFTER HOURS AND DURING WEEKEND). THE GENERAL CONTRACTOR
SHALL PREPARE SCHEDULE OF PHASES AND TIME OF PERFORMANCE FOR OWNER/TENANT AND CLIENT'S
REVIEW AT BID SUBMITTAL.
6.GENERAL CONTRACTOR SHALL CONTACT LANDLORD IN ADVANCE TO ARRANGE WHERE STOCK CAN BE
MOVED/STORED.
7.THE GENERAL CONTRACTOR SHALL AT ALL TIMES PROTECT THE PROPERTY OF THE BUILDING OWNER,
INCLUDING BUT NOT LIMITED TO, WINDOWS, MULLIONS, ELECTRICAL AND AIR CONDITIONING
EQUIPMENT, CONVECTOR ENCLOSURES, ETC. COLUMNS, FLOORS AND CEILING TILES, PUBLIC TOILETS,
ELEVATORS, DOORS, BUCKS.
8.THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, FITTING AND PATCHING WORK THAT MAY BE
REQUIRED TO MAKE ALL PARTS COME TOGETHER PROPERLY, AND FIT TO RECEIVE OR BE RECEIVED BY WORK
OF OTHER CONTRACTORS SHOWN UPON OR REASONABLY IMPLIED BY THE DRAWINGS AND NOTES.
9.CONTRACTOR SHALL PROVIDE ALL SUPPORTS AND SEISMIC BRACING REQUIRED FOR EXISTING BUILDING
ELEMENTS THAT ARE TO REMAIN (DUCTS, PIPES, ACOUSTICAL CEILING HANGER WIRES, LIGHT FIXTURES,
CONDUITS, SPRINKLER LINES, ETC.).
10.ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES EXCEPT ITEMS TO BE RE-USED OR
RETURNED TO TENANT OR AS OTHERWISE NOTED.
11.THE GENERAL CONTRACTOR SHALL REMOVE FROM PREMISES CONDUITS LEFT AFTER WALL DEMOLITION,
INCLUDING SWITCH BOXES, PLATES, BRIDGES, OR ANY OTHER TELEPHONE OR ELECTRICAL WIRING AND
EQUIPMENT. U.O.N.
12.THE GENERAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHTS THROUGHOUT THE SPACE
UNDER CONSTRUCTION AS REQUIRED.
13.THE GENERAL CONTRACTOR SHALL CAP AND FLUSH OFF BEHIND FINISH SURFACES ALL PROJECTING
PLUMBING, FLOOR ELECTRICAL/TELEPHONE OUTLETS, AND ALL OTHER PROJECTING ITEMS WHICH ARE BEING
ABANDONED.
14.TERMINATE AND PATCH ALL ABANDONED/UNUSED ELECTRICAL, DATA/TELEPHONE OUTLETS, THERMOSTATS
AND LIGHT SWITCHES AS NOTED ON PLANS.
15.PIPES AND CONDUIT ENCOUNTERED IN DEMOLISHED PARTITIONS AND AREAS WHICH ARE TO REMAIN IN USE
SHALL BE RE-ROUTED AND CONCEALED. THOSE WHICH ARE TO BE ABANDONED SHALL BE CAPPED AND
CONCEALED IN FLOOR, WALL OR CEILING.
16.UPON COMPLETION OF THE DEMOLITION WORK, THE GENERAL CONTRACTOR SHALL PROVIDE THAT ALL
AREAS BE LEFT BROOM CLEAN.
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
ID0.1
GENERAL NOTES
GENERAL REFLECTED CEILING PLAN NOTES
1.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LIGHT FIXTURES AND ELECTRICAL WORK AS SHOWN OR
IMPLIED IN DRAWINGS AND NOTES.
2.THE MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT
IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK DRAWINGS FOR COORDINATION PRIOR TO BIDDING AND
AGAIN PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL WORK. ANY DISCREPANCY BETWEEN THE
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF MAD FOR CLARIFICATION. WORK INSTALLED IN
CONFLICT WITH MAD'S DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR'S
EXPENSE AND SHALL NOT IMPACT THE SCHEDULE.
3.CEILING HEIGHTS AND DETAILING SHALL BE AS INDICATED IN DRAWINGS. ANY DEVIATION FROM HEIGHT OR
DETAILING INDICATED SHALL BE SUBMITTED TO MAD FOR REVIEW PRIOR TO BIDDING.
4.REFER TO PLAN FOR ALL CEILING HEIGHTS. GENERAL CONTRACTOR SHALL VERIFY CLEARANCES BETWEEN
DUCTWORK, LIGHT FIXTURES, AND OTHER OBSTRUCTIONS IN THE CEILING PLENUM TO ASSURE THE FINISH
CEILING HEIGHT.
5.FOR DETAILS AND SPECIFICATIONS OF LIGHTING FIXTURES, SWITCHES, PANEL BOXES, DIMMER CONTROLS,
CIRCUITING, AIR CIRCUITING, AIR CONDITIONING, DUCTWORK AIR SUPPLY DIFFUSERS, AIR RETURN GRILLES,
JUMP DUCT, THERMOSTATS, SMOKE DETECTORS, ETC., SEE ELECTRICAL AND MECHANICAL DRAWINGS.
6.THE CEILING WORK SHALL BE CLOSELY COORDINATED WITH THAT OF OTHER TRADES WHEREVER IT IS
CONTIGUOUS.
7.GENERAL CONTRACTOR SHALL ENSURE COMPLIANCE WITH CURRENT TITLE 24.
8.GENERAL CONTRACTOR TO RE-CIRCUIT/RE-SWITCH ALL LIGHTING AS REQUIRED TO COMPLY WITH NEW
DESIGN AND LOCAL CODES. SWITCHING OF ALL OFFICES/ENCLOSED ROOMS SHALL COMPLY WITH TITLE 24
REQUIREMENTS.
9.GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND DIMENSIONS AND NOTIFY MAD
OF ANY DISCREPANCIES ADVERSELY AFFECTING THE LIGHTING DESIGN AND/OR INSTALLATION (INCLUDING
CONFLICTS WITH STRUCTURE, MECHANICAL EQUIPMENT, DUCTWORK, ETC.) PRIOR TO PROCEEDING WITH
THE WORK.
10.FASCIAS OR ANY OTHER TRANSITION IN CEILING HEIGHT CREATED BY THE INSTALLATION AND/OR
ALTERATION OF HVAC DUCTS, PIPING, OR OTHER EQUIPMENT SHALL BE CONSTRUCTED OF GYPSUM BOARD
ON METAL FRAMING.
11.ALL JOINTS IN THE CEILING TILE FIELD SHALL BE SQUARE, LEVEL, AND PERFECTLY ALIGNED WITH EACH OTHER
AND WITH RECESSED LIGHT FIXTURES.
12.THE GENERAL CONTRACTOR SHALL PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL
CEILING TILE AS REQUIRED FOR LIGHT FIXTURES, REGISTERS, DIFFUSERS AND OTHER INSERTED ITEMS.
13.THE GENERAL CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DAMAGED CEILING TILES WHICH ARE
REMOVED TO FACILITATE PLENUM SYSTEMS INSTALLATIONS.
14.PRIOR TO CLOSING CEILINGS, PLENUM SYSTEMS (HVAC, PLUMBING, ELECTRICAL, ETC.) SHALL BE INSPECTED
AND TESTED AS REQUIRED BY CONTRACTOR'S ENGINEER AND BY AUTHORITIES HAVING JURISDICTION TO
ENSURE PROPER INSTALLATION AND FUNCTION.
15.THE GENERAL CONTRACTOR SHALL NOT BE REQUIRED TO OPEN ANY CEILINGS FOR TELEPHONE, SECURITY,
OR COMPUTER DATA SYSTEMS INSTALLATION, REPAIR, OR RECONFIGURATION AFTER CEILINGS ARE CLOSED.
IF SUCH WORK IS REQUIRED, THE EXPENSE TO REOPEN CEILINGS SHALL BE BORNE BY THE PARTY
RESPONSIBLE.
16.THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL NEW LIGHT FIXTURES (COMPLETE WITH LAMPS) OF
TYPES AND MANUFACTURERS SPECIFIED.
17.WHEN NOTED ON THE DRAWINGS TO REMOVE & RELOCATE EXISTING LIGHT FIXTURES, THEY SHALL BE
REFURBISHED, CLEANED, AND RELAMPED AS REQUIRED.
18.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD SUPERVISION OF ALL MECHANICAL WORK
DURING INSTALLATION AND SHALL INSPECT ALL SYSTEMS FOR OPERATION AND CODE COMPLIANCE AT
COMPLETION OF THE JOB.
19.LOCATE NEW DIFFUSERS TO ALIGN WITH NEW FIXTURE PATTERNS. COORDINATE DIFFUSER INSTALLATION TO
AVOID CONFLICT WITH WORK OF OTHER TRADES IN PLENUM.
20.WHEN NOTED FOR EXISTING DIFFUSERS TO BE REMOVED & RELOCATED, THEY SHALL BE CLEANED AND
REFURBISHED AS REQUIRED. COORDINATE DIFFUSER INSTALLATION TO AVOID CONFLICT WITH WORK OF
OTHER TRADES IN PLENUM.
21.LOCATE HVAC GRILLES TO MINIMIZE SOUND TRAVEL FROM AREA TO AREA. NOTIFY MAD OF ANY
ANTICIPATED ACOUSTICAL PROBLEMS BEFORE START OF WORK.
22.ALLOWANCE SHALL BE MADE FOR LATERAL MOVEMENT OF THE SYSTEM. MAIN RUNNERS AND CROSS
RUNNERS SHALL BE ATTACHED AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND THE
RUNNERS MAINTAINED AT THE OTHER TWO WALLS. REFER TO DETAILS ON SHEET ID5.2.
23.INSTALL SUPPORT WIRES AND CROSS RUNNERS TO AVOID CONTACT WITH HVAC EQUIPMENT AND
DUCTWORK.
24.THE GENERAL CONTRACTOR SHALL COORDINATE FIRE/LIFE SAFETY PERMITS WITH THE BUILDING'S FIRE/LIFE
SAFETY CONTRACTOR AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE FIRE/LIFE SAFETY
SYSTEM REQUIREMENTS AND THE PLANS.
25.FIRE SPRINKLERS - PROVIDE COMPLETE SYSTEM INCLUDING, BUT NOT LIMITED TO, PIPING, VALVES, SPRINKLER
DROPS, AND SPRINKLER HEADS. USE REFLECTED CEILING PLANS FOR LAYOUT GUIDELINES. ALL SPRINKLER
HEADS SHALL BE FULLY RECESSED (FLUSH TO CEILING).
26.RE-WORK, RELOCATE, RETROFIT AND/OR INSTALL NEW FIRE/LIFE SAFETY ANNUNCIATION DEVICES AS
REQUIRED TO COMPLY WITH LOCAL GOVERNING CODES.
27.EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHING SYSTEM AS NEEDED, TO BE APPROVED BY
BUILDING AND SAFETY MECHANICAL PLAN CHECK PRIOR TO INSTALLATION.
28.FURNISH AND INSTALL SMOKE DETECTORS PER ELECTRICAL ENGINEER'S DRAWINGS. LOCATION AND
QUANTITY OF SMOKE DETECTORS WITHIN TENANT SPACE SHALL BE DETERMINED BY THE FIRE MARSHAL.
29.WHERE CEILINGS ARE SPECIFIED TO BE OF FIRE-RATED CONSTRUCTION, ALL RECESSED LIGHT FIXTURES,
SPEAKERS, ETC. SHALL BE BOXED OUT ABOVE THE CEILING WITH A FIRE-RATED ENCLOSURE EQUAL TO THAT
OF THE CEILING.
30.GENERAL CONTRACTOR SHALL COORDINATE WORK TO ACCOMMODATE VARIATIONS IN CEILING HEIGHTS
AND EQUIPMENT INSTALLED THEREIN.
31.THE GENERAL CONTRACTOR SHALL VERIFY THAT SPRINKLER AND HVAC PLACEMENT COMPLIES WITH ALL
APPLICABLE LOCAL CODE REQUIREMENTS AND RE-WORK AS NECESSARY.
32.ALL SUSPENDED GYP. BD CEILINGS SHALL RECEIVE SKIM COAT. PREP FOR FLAT PAINT FINISH WITHOUT ANY
APPARENT SEAMS OR IMPERFECTIONS. UNLESS OTHERWISE NOTED, REFER TO REFLECTED CEILING PLAN AND
FINISH PLANS PAINT SPEC, FINISH AND LOCATION.
33.CEILING FIXTURES, TERMINALS, AND DEVICES:
a.ALL LIGHT FIXTURES, AIR TERMINALS/GRILLS, OR OTHER DEVICES (REFERRED TO ALL BY COMMON TERM
FIXTURES HEREAFTER) SHALL BE MOUNTED IN A MANNER THAT WILL NOT COMPROMISE CEILING
PERFORMANCE.
b.ALL FIXTURES SHALL BE SUPPORTED DIRECTLY BY MAIN RUNNERS OR BY SUPPLEMENTAL FRAMING WHICH IS
SUPPORTED BY MAIN RUNNERS AND POSITIVELY ATTACHED WITH SCREWS OR OTHER APPROVED
CONNECTORS.
c.SURFACE MOUNTED FIXTURES SHALL BE ATTACHED TO A MAIN RUNNER WITH A POSITIVE CLAMPING DEVICE
MADE OF MATERIAL WITH A MINIMUM OF 14 GAGE. ROTATIONAL SPRING CLAMPS DO NOT COMPLY.
d.ACCESS PANELS: ACCESS TO THE SPACE BETWEEN THE CEILING AND THE FLOOR OR ROOF ABOVE SHALL
NOT BE ALLOWED. SMALL ACCESS PANELS FOR THE INSPECTION, ADJUSTMENT, OR REPAIR OF UTILITY
SWITCHES, VALVES, SENSORS, ETC MAY BE ALLOWED IF THE PANEL IS LESS THAN 300 SQUARE INCHES. SUCH
PANELS SHALL ALSO HAVE PERMANENT WARNING LABEL AS FOLLOWS:
WARNING: 1. DO NOT CLIMB, WALK, OR CRAWL ON THE GYPSUM BOARD CEILING.
2. DO NOT STORE OR STOW ANYTHING ON THE GYPSUM BOARD CEILING.
e.ALL LIGHT FIXTURES WEIGHING LESS THAN OR EQUAL TO 10 LB. SHALL HAVE ONE NO. 12 GAUGE SAFETY
WIRE CONNECTED FROM FIXTURE HOUSING TO STRUCTURE ABOVE. IT IS NOT NECESSARY FOR THESE SAFETY
WIRES TO BE TAUT.
f.ALL FIXTURES WEIGHING GREATER THAN 10 LB. BUT LESS THAN OR EQUAL TO 56 LB. SHALL HAVE TWO NO. 12
GAUGE SAFETY WIRE CONNECTED FROM FIXTURE HOUSING TO STRUCTURE ABOVE. IT IS NOT NECESSARY
FOR THESE SAFETY WIRES TO BE TAUT.
g.ALL FIXTURES WEIGHING GREATER THAN 56 LB. SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE BY
APPROVED HANGERS.
h.PENDANT-HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE USING NO LESS THAN
NO. 9 GAUGE WIRE OR AN APPROVED ALTERNATE SUPPORT. THE CEILING SUSPENSION SYSTEM SHALL NOT
PROVIDE ANY DIRECT SUPPORT.
i.ALL RECESSED OR DROP-IN FIXTURES SHALL BE SUPPORTED DIRECTLY FROM FIXTURE HOUSING TO THE
STRUCTURE ABOVE WITH A MINIMUM OF TWO NO. 12 GAUGE WIRES LOCATED AT DIAGONALLY OPPOSITE
CORNERS. LEVELING OR POSITIONING OF FIXTURES MAY BE PROVIDED BY CEILING GRID. FIXTURE SUPPORT
WIRES MAY BE SLIGHTLY LOOSE TO ALLOW THE FIXTURE TO SEAT IN THE GRID SYSTEM. FIXTURES SHALL NOT
BE SUPPORTED FROM MAIN RUNNERS OR FURRING CHANNELS IF THE WEIGHT OF THE FIXTURES CAUSES
TOTAL LOAD TO EXCEED THE DEFLECTION CAPABILITY OF THE CEILING SUSPENSION SYSTEM.
j.PROVIDE A 2-INCH OVERSIZED RING, ADAPTER OR SLEEVE ON SPRINKLER AND SIMILAR PENETRATIONS TO
ALLOW FOR A 1-INCH HORIZONTAL DISPLACEMENT IN ANY DIRECTION.
34.ANY WALL MOUNTED FIXTURES SHALL BE MOUNTED SO AS NOT TO PROTRUDE BEYOND 4" FROM THE FACE
OF THE WALL IF MOUNTED AT HEIGHT OF LESS THAN 6'-8" A.F.F.
35.GENERAL CONTRACTOR SHALL FURNISH MAD WITH PLANS SHOWING LOCATIONS OF ALL LIGHT SENSORS,
EMERGENCY LIGHT STROBES, SMOKE DETECTORS, LIFE SAFETY PUBLIC ANNOUNCEMENT SPEAKERS AND
THERMOSTATS FOR REVIEW PRIOR TO ORDERING AND INSTALLATION.
36.CUT SHEETS AND/OR SHOP DRAWINGS OF ALL REGISTERS AND ACCESS PANELS (AS REQUIRED) SHALL BE
SUBMITTED TO MAD FOR REVIEW PRIOR TO FABRICATION, INSTALLATION, OR RELOCATION.
37.CONTRACTOR SHALL SUBMIT MECHANICAL AND SPRINKLER DRAWINGS TO MAD FOR APPROVAL OF
LOCATION OF SPRINKLER HEADS AND HVAC GRILLES.
38.THE GENERAL CONTRACTOR SHALL SUBMIT ONE (1) ELECTRONIC (PDF PREFERRED) SUBMITTAL OF SPECIFIED
LIGHT FIXTURES AND EQUIPMENT. IN ADDITION, TWO (2) FULL WORKING SAMPLES OF SPECIFIED LIGHT
FIXTURES SHALL BE SUBMITTED, IF REQUESTED BY MAD.
GENERAL FLOOR FINISH NOTES
1.ALL INTERIOR FINISHES SHALL CONFORM WITH CURRENT CBC CHAPTER 8 AND ARE TO COMPLY WITH CLASS
III FLAME-SPREAD REQUIREMENTS.
2.FLOORING SHALL MEET ALL CURRENT NON-SLIP STANDARDS AND REQUIREMENTS SPECIFIED BY APPLICABLE
CODES AND/OR AUTHORITIES. CONTRACTOR SHALL PROVIDE NON-SLIP COATINGS AS NECESSARY TO MEET
THESE REQUIREMENTS.
3.ALL MATERIALS AND INSTALLATIONS OF THE SAME SHALL COMPLY WITH ALL APPLICABLE LOCAL BUILDING,
FIRE AND ADA MUNICIPAL CODES.
4.ALL NEW FINISH FLOOR SHALL BE INSTALLED BY CONTRACTOR AS SPECIFIED ON FINISH PLANS.
5.ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY. WHEN THE WORK IS COMPLETE, IT SHALL BE FREE FROM
BUCKLES, BUBBLES, OPEN JOINTS, OR OTHER IMPERFECTIONS. SEAMS SHALL BE KEPT IN ACCURATE
ALIGNMENT ALONG BOTH COORDINATES. TILES HAVING CHIPPED OR ROUNDED CORNERS WILL BE
REJECTED AND IF INSTALLED, SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE TILES AT CONTRACTOR'S
EXPENSE.
6.THE GENERAL CONTRACTOR SHALL FLASH ALL CRACKS, HOLES, OR OTHER IMPERFECTIONS (PROJECTIONS
SHALL BE REMOVED AND PATCHED) TO PROVIDE A CONTINUOUSLY SMOOTH FLOOR SURFACE WITH
VARIATION IN LEVEL NOT TO EXCEED 1/4" IN 10'-0" NON-CUMULATIVE.
7.THE GENERAL CONTRACTOR SHALL NOTIFY MAD AFTER FLOOR PATCHING IS COMPLETE FOR FIELD
INSPECTION PRIOR TO THE INSTALLATION OF FINISH FLOOR.
8.GENERAL CONTRACTOR SHALL COORDINATE WORK OF ALL FLOORING CONTRACTORS TO ENSURE THAT
ALL VARYING FLOOR MATERIALS USED ARE INSTALLED FLUSH. ALL TRANSITION METHODS SHALL BE APPROVED
BY MAD PRIOR TO INSTALLATION.
9.GENERAL CONTRACTOR SHALL FOLLOW ALL MANUFACTURERS RECOMMENDATIONS AND INSTRUCTIONS
FOR THE INSTALLATION OF ANY FINISHES OR PRODUCTS.
10.TILES SHALL BE LAID IN SQUARE PATTERN WITH COURSES PARALLEL TO WALLS, U.O.N. ON THE DRAWINGS.
TILES SHALL BE SECURELY CEMENTED AND SHALL BE LAID WITH TIGHT JOINTS. THE ADHESIVE USED FOR
CEMENTING THE TILES SHALL BE APPLIED FAR ENOUGH IN ADVANCE OF SETTING TO PERMIT THE ADHESIVE
TO REACH ITS INITIAL SET, BUT NOT ITS FINAL SET. ADHESIVES USED ARE TO BE NON-COMBUSTIBLE.
11.AREAS WHERE FLOOR FINISH IS SCHEDULED SHALL BE CLOSED TO TRAFFIC AND OTHER WORK DURING
INSTALLATION OF FINISH FLOOR.
12.UPON COMPLETION, ALL FLOOR FINISH WORK SHALL BE CLEANED BY THE CONTRACTOR, REMOVING ALL
SPOTS OF ADHESIVE, SURFACE STAINS, AND ALL SCRAPS. CARTONS AND CONTAINERS SHALL BE REMOVED
FROM THE BUILDING.
13.AFTER CLEANING, THE CONTRACTOR SHALL PROVIDE (2) APPLICATIONS OF AN APPROVED NON-SLIP WAX TO
RESILIENT TILE FLOOR, WHICH SHALL BE THOROUGHLY MACHINE-BUFFED AND LEFT IN CONDITION ENTIRELY
ACCEPTABLE TO MAD.
14.THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE PROTECTION FOR ALL FLOORING WORK FOR
THE DURATION OF THE CONTRACT. ALL PROTECTION SHALL BE REMOVED PRIOR TO PUNCH LIST.
15.ACCURATE, DIMENSIONED FLOORING PLANS SHALL BE SUBMITTED TO MAD FOR APPROVAL PRIOR TO
INSTALLATION. ELECTRONIC FILE (PDF PREFERRED) SUBMITTAL IS ACCEPTABLE.
16.GENERAL CONTRACTOR SHALL FOLLOW ALL MANUFACTURERS RECOMMENDATIONS AND INSTRUCTIONS
FOR THE INSTALLATION OF ALL FINISHES OR PRODUCTS.
17.GENERAL CONTRACTOR SHALL SUBMIT AN ELECTRONIC FILE (PDF PREFERRED) OF CARPET SEAMING DIAGRAM
INCLUDING DIRECTION OF CARPET TO MAD FOR APPROVAL PRIOR TO ORDERING AND PRIOR TO
INSTALLATION OF MATERIALS.
18.PLASTIC LAMINATE BASE SHALL BE PROVIDED ON ALL MILLWORK SCHEDULED TO RECEIVE PLASTIC LAMINATE
FINISH (SEE ELEVATIONS).
19.GENERAL CONTRACTOR SHALL SUBMIT (3) 8" X 8" SAMPLES OF ALL FINISHES TO MAD FOR APPROVAL, PRIOR
TO PURCHASE OR INSTALLATION.
20.NO SUBSTITUTIONS OF FINISHES SHALL BE MADE WITHOUT PRIOR WRITTEN APPROVAL FROM MAD.
GENERAL MILLWORK NOTES
1.REFER TO SHEET ID3.0 FOR EQUIPMENT, FIXTURE, AND MILLWORK HARDWARE/ACCESORY SCHEDULES FOR
CONTRACTOR SUPPLIED EQUIPMENT, FIXTURE, AND HARDWARE/ACCESSORIES.
2.ALL PLASTIC LAMINATE MILLWORK TO BE FABRICATED, ASSEMBLED, FINISHED AND ERECTED TO AWI CUSTOM
GRADE STANDARDS. ALL EXPOSED AND SEMI-EXPOSED SURFACES TO BE FINISHED WITH SCHEDULED PLASTIC
LAMINATE. MILLWORK TO BE 5/8" MELAMINE. MILLWORK FINISH, U.O.N.: BLACK AT COLOR PLASTIC
LAMINATE MILLWORK. WHITE AT WHITE OR LIGHT COLORED PLASTIC LAMINATE MILLWORK.
3.ALL VENEERED OR LACQUERED MILLWORK SHALL BE FABRICATED, ASSEMBLED, FINISHED AND ERECTED TO
AWI PREMIUM GRADE STANDARDS. ALL EXPOSED SURFACES INCLUDING DOORS, DRAWERS, FRONTS,
COUNTERTOPS AND BASE SHALL BE VENEERED. UNLESS OTHERWISE NOTED, MILLWORK SHALL BE FULLY
VENEERED.
4.THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE.
ALL INSTALLED MILLWORK SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES.
5.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING FIELD DIMENSIONS IN ALL AREAS SCHEDULED
TO RECEIVE CABINETS NOTED HEREIN.
6.ALL INSTALLED MILLWORK SHALL BE SCRIBED TO WALL OR CEILING. CONTRACTOR SHALL COORDINATE
MILLWORK INSTALLATION WITH THE WORK OF ALL TRADES WHICH HAVE AN IMPACT ON MILLWORK.
7.PROVIDE BRACING IN WALLS AS REQUIRED FOR OVERHEAD CABINETS. WHERE OPEN SHELVING IS INDICATED
PROVIDE ALL EXPOSED EDGE SURFACES WITH PLASTIC LAMINATE FINISHES AND INTERIOR SURFACE WITH
WHITE KORTRON OR MELAMINE.
8.GENERAL CONTRACTOR SHALL ENSURE THAT MILLWORK CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOB
SITE CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO MAD PRIOR TO FABRICATION OF CABINET
WORK.
9.ALL MILLWORK IS TO BE FABRICATED IN A CONTROLLED SHOP ENVIRONMENT. FIELD WORK SHALL BE LIMITED
TO BLOCKING, TRIMMING, AND ASSEMBLED FINISHED COMPONENTS.
10.ALL MILLWORK JOINERY SHALL BE FABRICATED AND SECURED IN A MANNER WHICH ENSURES THAT THE JOINT
WILL NOT SEPARATE.
11.ALL CUTOUTS IN PLASTIC LAMINATE COUNTER TOPS (SINKS, GROMMET CHASES, ETC.) SHALL BE MADE BY
CABINET SUBCONTRACTOR AT SITE.
12.ALL WOOD VENEER PIECES SHALL BE FINISHED IN THE SHOP WITH SPRAY EQUIPMENT. NO FINISHING OTHER
THAN TOUCHUP TO BE DONE AT JOB SITE.
13.ALL REVEALS SHALL BE 1/8" U.O.N. AND BE ADJACENT WOOD FINISH OR ADJACENT PLASTIC LAMINATE WHERE
SPECIFIED. REFER TO ELEVATIONS.
14.GENERAL CONTRACTOR SHALL COORDINATE APPROPRIATE MUD RINGS FOR OUTLETS LOCATED ON FULL
HEIGHT BACKSPLASH.
15.GENERAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL NECESSARY HARDWARE AS REQUIRED BY THE
SPECIFICATIONS OR INTENT OF THE DESIGNER. SUBMITTALS OF MILLWORK HARDWARE SHALL BE SUBMITTED
TO MAD FOR APPROVAL BEFORE ASSEMBLY.
16.CABINET HARDWARE - SEE MILLWORK HARDWARE/ACCESSORY SCHEDULE SHEET ID3.0 (U.O.N.):
a.ALL HINGES AT ALL MILLWORK SHALL BE FULLY CONCEALED.
b.ALL DRAWER GLIDES SHALL BE FULL EXTENSION EXTRA HEAVY DUTY; GLIDES TO BE BLACK AT BLACK
CASEWORK; SILVER OR WHITE AT WHITE CASEWORK.
c.ALL GROMMETS SHALL BE DOUG MOCKETT "THE MAX" SATIN ALUMINUM FINISH OR APPROVED EQUAL. ALL
GROMMET LOCATIONS TO BE FIELD VERIFIED BY ARCHITECT PRIOR TO INSTALLATION.
d.PEDESTAL CABINETS TO ACCOMMODATE PENDEFLAX LETTER AND/OR LEGAL FOLDERS. PROVIDE METAL
BRACES.
e.WASTE RECEPTACLE DRAWERS SHALL HAVE TWO (2) SETS OF HEAVY DUTY GLIDES.
17.ALL MILLWORK FINISHES SHALL BE AS SPECIFIED ON PLANS, SCHEDULES, ELEVATIONS AND/OR DETAILS,
U.O.N.
18.GENERAL CONTRACTOR TO SUBMIT AN ELECTRONIC FILE (PDF PREFERRED) MILLWORK SHOP DRAWINGS FOR
APPROVAL BEFORE FABRICATION AND INSTALLATION. CONFIRM FINISHES ON SHOP DRAWINGS FOR MAD'S
APPROVAL BEFORE FABRICATION. SUBMIT (4) 12"x12" SAMPLES OF EACH FINISH FOR APPROVAL.
19.ALL SPECIAL MILLWORK PRODUCTS AND SPECIAL ASSEMBLIES ARE SUBJECT TO SUBMITTAL AND REVIEW. SHOP
DRAWINGS AND SUBMITTALS SHALL NOT BE WAIVED UNLESS WRITTEN PERMISSION TO DO SO IS GIVEN BY
MAD.
20.MILLWORK SHOP DRAWINGS SHALL CALL OUT ALL MATERIALS AND FINISHES. ALL JOINTS, CORNERS, AND
EDGES SHALL BE DESCRIBED IN DETAIL DRAWINGS. ALL DIMENSIONS, CRITICAL OR OTHERWISE, SHALL BE
CALLED OUT ON THE SHOP DRAWINGS. MAD WILL NOT REVIEW SHOP DRAWINGS WHICH ARE INCOMPLETE
AND/OR WHICH SHOW MINIMAL DETAIL.
GENERAL WALL FINISH NOTES
1.ALL INTERIOR FINISHES SHALL CONFORM WITH CURRENT CBC CHAPTER 8.
2.ALL AREAS ARE TO BE PAINTED IN ACCORDANCE WITH FINISH PLANS UNLESS OTHERWISE NOTED OR
SPECIFIED.
3.PAINT COLORS AND ALL OTHER WALL FINISHES INCLUDING WALL COVERING SHALL BE AS SPECIFIED BY MAD.
4.THE GENERAL CONTRACTOR SHALL USE SPECIFIED PAINT PRODUCTS. IF SUBSTITUTION OF MANUFACTURER
IS REQUESTED, THE CONTRACTOR SHALL PROVIDE MANUFACTURER'S LITERATURE, INCLUDING FULL
APPLICATION SPECIFICATIONS, TO MAD FOR APPROVAL IN ADVANCE OF APPLICATION.
5.WALLS SHALL BE DEFINED AS SURFACES FROM FLOOR TO CEILING, INCLUDING PILASTERS, FASCIAS, JAMBS,
BUCKS, REVEALS, RETURNS, AND ALL VERTICAL SURFACES NOT INCLUDED IN CEILING.
6.INDICATIONS OF EXTENT OF WALL FINISH ARE GRAPHICALLY SYMBOLIC AND DO NOT REPRESENT EVERY
JOG, PROTRUSION, OR RECESS OCCURRING ON THE ACTUAL CONSTRUCTED SURFACE (NEW OR EXISTING).
THE CONTRACTOR SHALL PROVIDE SPECIFIED FINISH ON ALL SURFACES WITHIN THE LIMITS SHOWN ON THE
PLANS.
7.THE CONTRACTOR SHALL INSPECT ALL SURFACES FOR HOLES, CRACKS, AND ANY OTHER CONDITIONS
WHICH WOULD ADVERSELY IMPACT PAINT APPLICATION. ALL EXISTING LOOSE PAINT SHALL BE REMOVED.
ALL SURFACES SHALL BE PROPERLY PREPARED, PATCHED AS APPROPRIATE TO A SMOOTH CONDITION, AND
MADE READY FOR PRIME AND PAINT. THE CONTRACTOR SHALL NOT PROCEED WITH THE PAINTING WORK
UNTIL THIS HAS OCCURRED AT ALL SURFACES SCHEDULED TO RECEIVE PAINT.
8.COMMENCEMENT OF PAINTING WORK SHALL REPRESENT ACCEPTANCE OF SURFACE CONDITIONS.
9.THE GENERAL CONTRACTOR SHALL CAREFULLY REMOVE AND STORE ALL ELECTRICAL SWITCH AND OUTLET
PLATES, SURFACE HARDWARE, ETC. PRIOR TO PAINTING AND REPLACE THEM WHEN PAINTING WORK IS
COMPLETE. ALL PAINT SPILLED, SPLASHED, OR SPLATTERED ON DIFFUSERS, REGISTERS, SLAB FITTINGS, ETC.
SHALL BE REMOVED WHEN PAINTING WORK IS COMPLETE. THE CONTRACTOR SHALL REPLACE ANY ITEMS
DAMAGED DURING THIS PROCESS WITH NEW ITEM TO MATCH EXISTING.
10.ALL WOOD SHELVING AND PAINTED DOORS SHALL RECEIVE PRIMING, SANDING, AND (2) FULL COATS OF
SEMI-GLOSS ENAMEL FREE OF BRUSH MARKS. THE CONTRACTOR SHALL EXAMINE ALL AREAS OF
CONSTRUCTION AFTER COMPLETION OF ALL WORK AND PERFORM NECESSARY "TOUCH-UP" PAINTING
AND/OR PATCHING.
11.THE GENERAL CONTRACTOR SHALL INSTALL WALL COVERING PER MANUFACTURER'S SPECIFICATIONS WHERE
INDICATED ON FINISH PLANS. WALL COVERING SHALL BE INSTALLED SMOOTH, WITHOUT WRINKLES,
BUBBLES OR LOOSE EDGES. ALL PASTE AND BRUSH MARKS SHALL BE REMOVED. WALL COVERING
ADJOINING WOOD AND METAL TRIM SHALL BE CUT STRAIGHT AND SQUARE. WALL COVERING AT ALL
REVEALS SHALL RETURN INTO REVEAL. ALL WORKMANSHIP WHICH IS NOT JUDGED TO BE FIRST QUALITY BY
MAD WILL NOT BE ACCEPTED.
13.REPAIR, PATCH (IF REQUIRED) EXISTING WALLS AND RE PAINT AS SPECIFIED.
14.SOFFIT AND FASCIA FINISH SHALL MATCH ADJACENT WALL COLOR, U.O.N.
15.SEE REFLECTED CEILING PLAN FOR CEILING FINISHES & LOCATION.
16.ALL ACCESS DOORS AND PANELS LOCATED IN DRYWALL CEILINGS AND WALL SHALL BE PAINTED TO MATCH
ADJACENT SURFACE COLOR AND FINISH, U.O.N.
17.GENERAL CONTRACTOR SHALL COORDINATE ALL FINISHES ON MILLWORK AS SHOWN ON MILLWORK PLANS
WITH THE MILLWORK SUB-CONTRACTOR.
GREEN BUILDING NOTES
1.INTERIOR AND EXTERIOR LIGHTING SHALL BE INSTALLED SUCH THAT ZERO DIRECT-BEAM ILLUMINATION
LEAVES THE BUILDING SITE.
2.ALL NEW EXTERIOR LUMINAIRES SHALL BE SHIELDED OR BE CUTOFF LUMINAIRES AS DEFINED IN SECTION 132
(b) OF THE CALIFORNIA ENERGY CODE.
3.NEW NON-RESIDENTIAL GRADE EQUIPMENT AND APPLIANCES PROVIDED AND INSTALLED SHALL BE ENERGY
STAR LABELED IF ENERGY STAR IS APPLICABLE TO THAT EQUIPMENT OR APPLIANCE.
4.NONABSORBENT FLOOR AND WALL FINISH SHALL BE USED WITHIN AT LEAST TWO FEET AND PERPENDICULAR
TO EXTERIOR ENTRIES AND/OR OPENING SUBJECT TO FOOT TRAFFIC.
5.WHEN PROJECT OCCURS WITHIN THE LOS ANGELES CITY LIMITS, ONLY A CITY OF LOS ANGELES CERTIFIED
HAULER WILL BE USED FOR HAULING OF CONSTRUCTION WASTE.
6."AN OPERATION AND SYSTEMS MANUAL" SHALL BE PROVIDED TO THE FIELD INSPECTOR AT THE TIME OF
FINAL INSPECTION.
7.ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE,
PLASTIC, OR SHEETMETAL UNTIL THE FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT.
8.THE VOC CONTENT VERIFICATION CHECKLIST, FORM GRN 2, SHALL BE COMPLETED AND VERIFIED PRIOR TO
FINAL INSPECTION APPROVAL. THE MANUFACTURER'S SPECIFICATIONS SHOWING VOC CONTENT FOR ALL
APPLICABLE PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD
INSPECTOR FOR VERIFICATION.
9.ALL NEW CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT
REQUIREMENTS OF ONE OF THE FOLLOWING:
a.CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM;
b.CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD PRACTICE FOR TESTING OF (VOLATILE
ORGANIC COMPOUNDS) VOCs (SPECIFICATION 01350);
c.NSF/ANSI 140 AT THE GOLD LEVEL; OR
d.SCIENTIFIC CERTIFICATIONS SYSTEMS INDOOR ADVANTAGE GOLD
10.ALL NEW CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET REQUIREMENTS OF THE
CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM.
11.THE FORMALDEHYDE EMISSIONS VERIFICATION CHECKLIST, FORM GRN 3, SHALL BE COMPLETED PRIOR TO
FINAL INSPECTION APPROVAL. THE MANUFACTURER'S SPECIFICATIONS SHOWING FORMALDEHYDE CONTENT
FOR ALL APPLICABLE WOOD PRODUCTS SHALL BE READILY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO
THE FIELD INSPECTOR FOR VERIFICATION.
12.50% OF THE TOTAL AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH THE VOC LIMITS OR BE
CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM.
13.AN AIR FILTER WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8 OR HIGHER SHALL BE INSTALLED
IN NEW MECHANICAL SYSTEMS FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY.
14.THE HVAC, REFRIGERATION, FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CFC OR HALONS.
15.ARCHITECTURAL PAINTS AND COATINGS, ADHESIVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE
VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN TABLES 10.504.4.1 - 10.504.4.3.
16.AEROSOL PAINTS AND COATINGS SHALL MEET THE PRODUCT-WEIGHTED MIR LIMITS FOR ROC IN SECTION
94522(A)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC
COMPOUNDS AND OZONE DEPLETING SUBSTANCES, IN SECTIONS 94522(C)(2) AND (D)(2) OF CALIFORNIA
CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520; AND IN AREAS UNDER THE
JURISDICTION OF THE SOUTH COAST AREA AIR QUALITY MANAGEMENT DISTRICT ADDITIONALLY COMPLY
WITH THE PERCENT VOC BY WEIGHT OF PRODUCT LIMITS OF REGULATION 8, RULE 49
17.ALL SEALERS, STAINS, AND FINISHES ON CONCRETE, WOOD, BAMBOO, OR CORK MUST COMPLY WITH THE
SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQD) RULE 113, ARCHITECTURAL COATINGS.
GENERAL CONTRACTOR SHALL SUBMIT ALL SEALERS, STAINS, AND FINISHES BEING USED ON THE PROJECT TO
WDG FOR APPROVAL PRIOR TO INSTALLATION.
18.NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATE
SPECIFIED IN TABLE 10.303.2.3.
19.A FINAL REPORT FOR THE TESTING AND ADJUSTING OF ALL NEW SYSTEMS SHALL BE COMPLETED AND
PROVIDED TO THE FIELD INSPECTOR PRIOR TO FINAL INSPECTION. THIS REPORT SHALL BE SIGNED BY THE
INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES.
20.NEW HARDWOOD PLYWOOD, PARTICLE BOARD, AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD
PRODUCTS USED IN THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE FORMALDEHYDE LIMITS
LISTED IN TABLE 10.504.4.5.
21.THE BUILDING SHALL MEET OR EXCEED THE PROVISIONS FOR MECHANICAL VENTILATION OF SECTION 1203
OR THE LOS ANGELES BUILDING CODE.
22.BUILDINGS THAT USE DEMAND CONTROL VENTILATION SHALL HAVE CO₂ SENSORS AND VENTILATION
CONTROLS INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THE
CALIFORNIA ENERGY CODE, CCR, TITLE 24, PART 6, SECTION 121(c).
23.IF THE NEW HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A
MERV OF 8. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPPANCY.
24.TESTING AND ADJUSTMENT IS REQUIRED FOR ALL NEW INSTALLATION OF ANY OF THE FOLLOWING SYSTEMS:
a. HEATING VENTILATING AND AIR CONDITIONING SYSTEM
i. DESCRIBE THE HVAC SYSTEMS AND CONTROLS.
ii. PLANS SHALL INDICATE THAT THE HVAC SYSTEM AND COMPONENTS WILL BE TESTED, ADJUSTED
AND BALANCED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
·TABB'S CONSTRUCTION SPECIFICATION INSTITUTE MASTERFORMAT
·NEBB'S STANDARDS FOR TESTING, ADJUSTMENT AND BALANCING OF ENVIRONMENTAL SYSTEMS
(7TH EDITION)
·AABC'S NATIONAL STANDARDS FOR TOTAL SYSTEM BALANCE (6TH EDITION)
·ASHRAE'S STANDARD 111-2008
b. INDOOR AND OUTDOOR LIGHTING AND CONTROLS:
i. DESCRIBE THE TYPES OF LIGHTING FIXTURES USED AND THEIR CORRESPONDING CONTROLS AT
VARIOUS SPACES/ROOMS WITHING THE BUILDING (E.G. DIMMERS, OCCUPANCY SENSORS,
PROGRAMMABLE TIME SWITCHES, PHOTOSENSORS, ETC.)
ii. PROVIDE A NARRATIVE OF THE TESTING AND ADJUSTMENT PROCEDURE FOR THE LIGHTING
CONTROLS.
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
ID0.2
GENERAL NOTES
FLOORS AND LEVELS
IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT, OR
SHALL BE CONNECTED BY PEDESTRIAN RAMPS OR PASSENGER ELEVATORS
GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN ACCESSIBLE ROOMS AND SPACES,
INCLUDING FLOORS, WALKS, RAMPS, STAIRS, AND CURB RAMPS, SHALL BE STABLE,FIRM, AND SLIP-RESISTANT
CHANGES IN LEVEL UP TO
INCH MAY BE VERTICAL AND WITHOUT EDGE TREATMENT
CHANGES IN LEVEL BETWEEN INCH AND INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN ONE
UNIT VERTICAL IN UNITS HORIZONTAL PERCENT SLOPE
CHANGES IN LEVEL GREATER THAN INCH SHALL BE ACCOMPLISHED BY MEANS OF A CURB RAMP, RAMP, OR
ELEVATOR
IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE, THEN IT SHALL BE SECURELY
ATTACHED HAVE A FIRM CUSHION, PAD OR BACKING OR NO CUSHION OR PAD AND HAVE A LEVEL LOOP,
TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUTUNCUT PILE TEXTURE THE MAXIMUM PILE HEIGHT SHALL BE õ
INCH EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG THE
ENTIRE LENGTH OF THE EXPOSED EDGE CARPET EDGE TRIM SHALL COMPLY WITH SECTION B
SIGNS & IDENTIFICATION
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OF A WHITE FIGURE ON A BLUE
BACKGROUND THE BLUE SHALL BE E4UAL TO COLOR NO IN FEDERAL STANDARD B
ALL BUILDING AND FACILITY ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH
DISABILITIES AND AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL
SHALL BE IDENTIFIED WITH A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY AND WITH
ADDITIONAL DIRECTIONAL SIGNS TO BE VISIBLE TO PERSONS ALONG APPROACHING CIRCULATION PATHS
WHERE PERMANENT IDENTIFICATION SIGNS ARE PROVIDED FOR ROOMS AND SPACES OF A BUILDING OR
SITE, RAISED CHARACTERS SHALL BE PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE IN CONFORMANCE
WITH SECTION B THROUGH B SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE
LATCH OUTSIDE OF THE DOOR WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT
DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE
RIGHT MOUNTING HEIGHT SHALL BE INCHES ABOVE THE FINISHED FLOOR TO THE CENTERLINE OF THE
SIGN MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN INCHES
OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A
DOOR
WHEN SIGNS DIRECT TO OR GIVE INFORMATION ABOUT PERMANENT ROOMS AND FUNCTIONAL SPACES OF
A BUILDING OR SITE, THEY SHALL COMPLY WITH SECTIONS B, B, AND B FOR
OTHER MEANS OF EGRESS SIGNS AND IDENTIFICATION SEE CHAPTER , SECTIONS , ,
, , , AND
WHEN RAISED CHARACTERS OR WHEN PICTOGRAM SYMBOLS ARE USED, THEY SHALL CONFORM TO THE
FOLLOWING
DCHARACTERS ON SIGNS SHALL BE RAISED -INCH MINIMUM AND SHALL BE SANS - SERIF UPPERCASE
CHARACTERS ACCOMPANIED BY CONTRACTED GRADE BRAILLE COMPLYING WITH SECTION B
ERAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF INCH HIGH AND A MAXIMUM OF INCHES
HIGH
FPICTORIAL SYMBOL SIGNS PICTOGRAMS SHALL BE ACCOMPANIED BY THE VERBAL DESCRIPTION PLACED
DIRECTLY BELOW THE PICTOGRAM THE OUTSIDE DIMENSION OF THE PICTOGRAM FIELD SHALL BE A
MINIMUM OF INCHES IN HEIGHT
GCHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT BRAILLE SHOULD BE PLACED A MINIMUM
OF -INCH AND A MAXIMUM OF õ-INCH DIRECTLY BELOW THE TACTILE CHARACTERS FLUSH LEFT OR
CENTERED WHEN TACTILE SIGN IS MULTI-LINED, ALL BRAILLE SHALL BE PLACED TOGETHER BELOW ALL LINES
OF TACTILE TEXT B
CHARACTERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN AND AND A STROKE
WIDTH-TO-HEIGHT RATIO BETWEEN AND
CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH CHARACTERS AND
SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT CHARACTERS ON A DARK
BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND
CHARACTERS AND NUMBERS ON SIGNS RE4UIRED TO BE ACCESSIBLE BY SECTION B ITEMS AND
SHALL BE SIZED ACCORDING TO THE TABLE IN SECTION B
CONTRACTED GRADE BRAILLE SHALL BE USED WHEREVER BRAILLE IS RE4UIRED IN OTHER PORTIONS OF
THESE STANDARDS DOTS SHALL BE INCH ON CENTERS IN EACH CELL WITH -INCH SPACE BETWEEN
CELLS DOTS SHALL BE RAISED A MINIMUM OF INCH ABOVE THE BACKGROUND
ENTRANCES & EXITS
ALL ENTRANCES AND EXTERIOR GROUND FLOOR EXIT DOORS TO BUILDINGS AND FACILITIES SHALL BE MADE
ACCESSIBLE TO PERSONS WITH DISABILITIES
EVERY RE4UIRED EXIT DOORWAY SHALL BE CAPABLE OF OPENING AT LEAST DEGREES, SHALL HAVE A
MINIMUM CLEAR OPENING OF INCHES, AND SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A
DOOR NOT LESS THAN FEET IN WIDTH AND FEET INCHES IN HEIGHT
THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENINGS IN A VESTIBULE, SERVING OTHER THAN A
RE4UIRED EXIT STAIRWAY, SHALL PROVIDE A MINIMUM OF INCHES OF CLEAR SPACE FROM ANY DOOR
OPENING INTO SUCH VESTIBULE WHEN THE DOOR IS POSITIONED AT AN ANGLE OF DEGREES FROM ITS
CLOSED POSITION DOORS IN A SERIES SHALL SWING EITHER IN THE SAME DIRECTION OR AWAY FROM THE
SPACE BETWEEN THE DOORS SEE FIGURES B- & B-
CONTROLS & OPERATING MECHANISMS
CONTROLS AND OPERATING MECHANISMS IN ACCESSIBLE SPACES, ALONG ACCESSIBLE ROUTES OR AS PART
OF ACCESSIBLE ELEMENTS AND THOSE IN SECTION ARE RE4UIRED TO BE ACCESSIBLE
CLEAR FLOOR SPACE COMPLYING WITH SECTION B THAT ALLOWS A FORWARD OR PARALLEL
APPROACH BY A PERSON USING A WHEELCHAIR SHALL BE PROVIDED AT CONTROLS, DISPENSERS,
RECEPTACLES, AND OTHER OPERABLE E4UIPMENT
THE HIGHEST AND LOWEST OPERABLE PART OF ALL CONTROLS, DISPENSERS, RECEPTACLES, AND OTHER
OPERABLE E4UIPMENT SHALL BE PLACED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTIONS
B AND B
CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT RE4UIRE
TIGHT GRASPING, PUNCHING, OR TWISTING OF THE WRIST THE FORCE RE4UIRED TO ACTIVATE CONTROLS
SHALL BE NO GREATER THAN POUNDS
FOR ACCESSIBLE LAVATORIES, FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH
ONE HAND AND SHALL NOT RE4UIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST THE FORCE
RE4UIRED TO ACTIVE FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE NO GREATER THAN LBF
LEVER-OPERATED, PUSH-TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF
ACCEPTABLE DESIGNS SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST
SECONDS
SPACE ALLOWANCE & REACH RANGES
THE MINIMUM CLEAR FLOOR OR GROUND SPACE RE4UIRED TO ACCOMMODATE A SINGLE, STATIONARY
WHEELCHAIR AND OCCUPANT IS INCHES BY INCHES THE MINIMUM CLEAR FLOOR OR GROUND
SPACE FOR WHEELCHAIRS MAY BE POSITIONED FOR FORWARD OR PARALLEL APPROACH TO AN OBJECT
CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE A PART OF THE KNEE SPACE RE4UIRED UNDER
SOME OBJECTS
ONE FULL-UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE FOR A WHEELCHAIR SHALL
ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER WHEELCHAIR CLEAR FLOOR SPACE IF A
CLEAR FLOOR OR GROUND SPACE IS LOCATED IN AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART
OF THREE SIDES, ADDITIONAL MANEUVERING CLEARANCES SHALL BE PROVIDED
THE SPACE RE4UIRED FOR A WHEELCHAIR TO MAKE A -DEGREE TURN IS A CLEAR SPACE OF INCHES
DIAMETER OR A T-SHAPED SPACE
THE MINIMUM CLEAR WIDTH RE4UIRED FOR A WHEELCHAIR TO TURN AROUND AN OBSTRUCTION SHALL BE
INCHES MINIMUM WHERE THE OBSTRUCTION IS INCHES OR MORE IN LENGTH INCHES MINIMUM
WHERE THE OBSTRUCTION IS LESS THAN INCHES IN LENGTH
THE MINIMUM CLEAR WIDTH FOR SINGLE WHEELCHAIR PASSAGE SHALL BE INCHES AT A POINT AND
INCHES CONTINUOUSLY
THE MINIMUM WIDTH FOR TWO WHEELCHAIRS TO PASS IS INCHES
IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD APPROACH TO AN OBJECT, THE MAXIMUM HIGH
FORWARD REACH ALLOWED SHALL BE INCHES SEE FIGURE B-CA THE MINIMUM LOW FORWARD
REACH IS INCHES IF THE HIGH FORWARD REACH IS OVER AN OBSTRUCTION, REACH AND CLEARANCES
SHALL BE AS SHOWN IN FIGURE B-CB
IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A PERSON IN A WHEELCHAIR, THE MAXIMUM
HIGH SIDE REACH ALLOWED SHALL BE INCHES AND THE LOW SIDE REACH SHALL BE NO LESS THAN
INCHES ABOVE THE FLOOR AS SHOWN IN FIGURES B-DA & B IF THE SIDE REACH IS OVER AND
OBSTRUCTION, THE REACH AND CLEARANCES SHALL BE AS SHOWN IN FIGURE B-DC
ELECTRICAL
THE HIGHEST OPERABLE PART OF ALL CONTROLS, DISPENSERS, RECEPTACLES AND OTHER OPERABLE
E4UIPMENT SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION MEETING THE CLEARANCES AND REACH
RANGE RE4UIREMENTS OF SECTIONS B AND B
CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO
CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, OR COOLING, HEATING, AND VENTILATING
E4UIPMENT, SHALL BE LOCATED NO MORE THAN INCHES MEASURED FROM THE TOP OF THE OUTLET
BOX NOR LESS THAN INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE
FINISH FLOOR OR WORKING PLATFORM
ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF AMPERES OR LESS AND COMMUNICATION
SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN INCHES MEASURED FROM THE TOP OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN INCHES MEASURED FROM THE
BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR
OR WORKING PLATFORM
EMPLOYEE WORK AREAS & WORK STATIONS
EMPLOYEE AREAS SHALL COMPLY WITH THE ACCESSIBILITY RE4UIREMENTS OF CHAPTER B
SPECIFIC WORKSTATIONS NEED ONLY COMPLY WITH AISLE WIDTH AND FLOORS AND LEVELS, AND
ENTRYWAYS SHALL BE INCHES IN CLEAR WIDTH AISLES SHALL NOT BE LESS THAN INCHES IF SERVING
ONLY ONE SIDE, AND NOT LESS THAN INCHES WIDE IF SERVING BOTH SIDES
EMPLOYEE WORK AREAS SHALL HAVE A MINIMUM OF INCHES CLEAR WIDTH ACCESS
FIXED OR BUILT-IN SEATING, TABLES & COUNTERS
WHERE FIXED OR BUILT-IN SEATING, TABLES, OR COUNTERS ARE PROVIDED IN ACCESSIBLE PUBLIC USE OR
COMMON USE AREAS, FIVE PERCENT BUT NEVER LESS THAN ONE MUST BE ACCESSIBLE, AS RE4UIRED IN
SECTION B
IF SEATING SPACES FOR PERSONS IN WHEELCHAIRS ARE PROVIDED AT FIXED TABLES OR COUNTERS, CLEAR
FLOOR SPACE COMPLYING WITH SECTION B SHALL BE PROVIDED SUCH CLEAR FLOOR SPACE SHALL
NOT OVERLAP KNEE SPACE BY MORE THAN INCHES
IF SEATING FOR PERSONS IN WHEELCHAIRS IS PROVIDED AT FIXED TABLES OR COUNTERS, KNEE SPACES AT
LEAST INCHES HIGH, INCHES WIDE, AND INCHES DEEP SHALL BE PROVIDED
THE TOPS OF TABLES AND COUNTERS SHALL BE INCHES TO INCHES FROM THE FLOOR OR GROUND
WHERE A SINGLE COUNTER CONTAINS MORE THAN ONE TRANSACTION STATION, SUCH AS A BANK
COUNTER WITH MULTIPLE TELLER WINDOWS OR A RETAIL SALES COUNTER WITH MULTIPLE CASH REGISTER
STATIONS, AT LEAST PERCENT, BUT NEVER LESS THAN ONE OF EACH TYPE OF STATION SHALL BE LOCATED
AT A SECTION OF COUNTER THAT IS AT LEAST INCHES LONG AND NO MORE THAN TO INCHES
HIGH
STAIRWAYS
STAIRWAYS SHALL HAVE HANDRAILS ON EACH SIDE HANDRAILS SHALL BE CONTINUOUS ALONG BOTH SIDES
OF THE STAIRWAY INTERMEDIATE HANDRAILS SHALL BE PROVIDED AS RE4UIRED IN SECTION
THE TOP OF HANDRAIL GRIPPING SURFACE SHALL BE MOUNTED TO INCHES ABOVE THE NOSING OF
THE TREADS
HANDRAILS SHALL EXTEND A MINIMUM OF INCHES BEYOND THE TOP NOSING AND INCHES PLUS THE
TREAD WIDTH BEYOND THE BOTTOM NOSING AT THE TOP, THE EXTENSION SHALL BE PARALLEL WITH THE
FLOOR OR GROUND SURFACE AT THE BOTTOM, THE HANDRAIL SHALL CONTINUE TO SLOPE FOR A
DISTANCE OF THE WIDTH OF ONE TREAD FROM THE BOTTOM RISER THE REMAINDER OF THE EXTENSION
SHALL BE HORIZONTAL SEE FIGURES B- AND B-
ENDS SHALL BE RETURNED SMOOTHLY TO FLOOR, WALL OR POST
THE HANDGRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN - INCHES OR MORE THAN -
INCHES IN CROSSSECTIONAL NOMINAL DIMENSION OR THE SHAPE SHALL PROVIDE AN E4UIVALENT
GRIPPING SURFACE THE HANDGRIP PORTION OF HANDRAILS SHALL HAVE A SMOOTH SURFACE WITH NO
SHARP CORNERS GRIPPING SURFACES TOP OR SIDES SHALL BE UNINTERRUPTED BY NEWEL POSTS, OTHER
CONSTRUCTION ELEMENTS, OR OBSTRUCTIONS ANY WALL OR OTHER SURFACE ADJACENT TO THE
HANDRAIL SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS EDGES SHALL HAVE A MINIMUM RADIUS OF
INCH
THE ORIENTATION OF AT LEAST ONE HANDRAIL SHALL BE IN THE DIRECTION OF THE RUN OF THE STAIR AND
PERPENDICULAR TO THE DIRECTION OF THE STAIR NOSING, AND SHALL NOT REDUCE THE MINIMUM
RE4UIRED WIDTH OF STAIRS
HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF - INCHES BETWEEN THE WALL AND THE
HANDRAIL HANDRAILS MAY BE LOCATED IN A RECESS IF THE RECESS IS A MAXIMUM OF INCH DEEP AND
EXTENDS AT LEAST INCHES ABOVE THE TOP OF THE RAIL HANDRAILS SHALL NOT ROTATE IN THEIR
FITTINGS
INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING
CLEAR VISUAL CONTRAST EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS MARKED BY A
STRIPE PROVIDING CLEAR VISUAL CONTRAST THE STRIPE SHALL BE A MINIMUM OF INCHES WIDE TO A
MAXIMUM OF INCHES WIDE PLACED PARALLEL TO, AND NOT MORE THAN INCH FROM, THE NOSE OF THE
STEP OR UPPER APPROACH THE STRIPE SHALL EXTEND THE FULL WIDTH OF THE STEP OR UPPER APPROACH
AND SHALL BE OF MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR A
PAINTED STRIPE SHALL BE ACCEPTABLE
STAIR TREADS SHALL BE NO LESS THAN INCHES DEEP, MEASURED FROM RISER TO RISER STAIR RISER
HEIGHTS SHALL BE INCHES MAXIMUM AND INCHES MINIMUM ON ANY GIVEN FLIGHT OF STAIRS, ALL
STEPS SHALL HAVE UNIFORM RISER HEIGHT AND UNIFORM TREAD WIDTHS
ALL TREAD SURFACES SHALL BE SLIP-RESISTANT WEATHER EXPOSED STAIRS AND THEIR APPROACHES SHALL BE
DESIGNED SO THAT WATER WILL NOT ACCUMULATE ON THE WALKING SURFACES TREADS SHALL HAVE
SMOOTH, ROUNDED, OR BEVELED EXPOSED EDGES
RISERS SHALL BE SOLID AND SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE LEADING EDGE OF
THE TREAD ABOVE AT AN ANGLE NOT MORE THAN DEGREES FROM THE VERTICAL OPEN RISERS ARE NOT
PERMITTED
THE RADIUS OF CURVATURE AT THE LEADING EDGE NOSING OF THE TREAD SHALL BE NO GREATER THAN õ
INCH BEVELING OF NOSINGS SHALL NOT EXCEED õ INCH NOSINGS SHALL NOT PROJECT MORE THAN
- INCHES PAST THE FACE OF THE RISER BELOW NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE
THE UNDERSIDE OF THE LEADING EDGE BEVELED AT AN ANGLE NOT MORE THAN DEGREES FROM THE
VERTICAL THE TRANSITION FROM THE NOSING TO THE RISER SHALL BE FREE OF ABRUPT EDGES ALL
PROJECTIONS SHALL BE OF UNIFORM SIZE, INCLUDING NOSINGS AT LANDINGS
TACTILE FLOOR IDENTIFICATION SIGNS RE4UIRED BY CHAPTER , SECTION THAT COMPLY WITH
SECTION B SHALL BE LOCATED AT EACH FLOOR LEVEL LANDING IN ALL ENCLOSED STAIRWAYS IN
BUILDINGS TWO OR MORE STORIES IN HEIGHT TO IDENTIFY THE FLOOR LEVEL AT EXIT DISCHARGE LEVEL,
THE SIGN SHALL INCLUDE A RAISED FIVEPOINTED STAR LOCATED TO THE LEFT OF THE IDENTIFYING FLOOR
LEVEL THE OUTSIDE DIAMETER OF THE STAR SHALL BE THE SAME AS THE HEIGHT OF THE RAISED CHARACTERS
HAZARDS AND PROTRUDING OBJECTS
ABRUPT CHANGES IN LEVEL, EXCEPT BETWEEN A WALK OR SIDEWALK AND AN ADJACENT STREET OR
DRIVEWAY, EXCEEDING INCHES IN A VERTICAL DIMENSION, SUCH AS AT PLANTERS OR FOUNTAINS
LOCATED IN OR ADJACENT TO WALKS, SIDEWALKS, OR OTHER PEDESTRIAN WAYS, SHALL BE IDENTIFIED BY
WARNING CURBS PROJECTING AT LEAST INCHES IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE TO
WARN THE BLIND OF A POTENTIAL DROP OFF
OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN INCHES AND INCHES
ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN INCHES INTO WALKS, HALLS, CORRIDORS,
PASSAGEWAYS, OR AISLES
OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW INCHES ABOVE THE FINISHED FLOOR
MAY PROTRUDE ANY AMOUNT INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES
FREESTANDING OBJECTS MOUNTED ON POSTS OR PYLONS MAY OVERHANG INCHES MAXIMUM FROM
INCHES TO INCHES ABOVE THE GROUND OR FINISHED FLOOR
PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING
SPACE
WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES, OR OTHER CIRCULATION SPACES SHALL HAVE INCHES
MINIMUM CLEAR HEADROOM
ANY OBSTRUCTION THAT OVERHANGS A PEDESTRIAN WAY SHALL BE A MINIMUM OF INCHES ABOVE THE
WALKING SURFACE AS MEASURED FROM THE BOTTOM OF THE OBSTRUCTION
MULTIPLE ACCOMMODATION SANITARY FACILITIES
A CLEAR SPACE MEASURED FROM THE FLOOR TO A HEIGHT OF ABOVE THE FLOOR, WITHIN THE
SANITARY FACILITY ROOM, OF SUFFICIENT SIZE TO INSCRIBE A CIRCLE WITH A DIAMETER NOT LESS THAN
OTHER THAN THE DOOR TO THE ACCESSIBLE WATER CLOSET COMPARTMENT, A DOOR, IN ANY POSITION,
MAY ENCROACH INTO THIS SPACE BY NOT MORE THAN
DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE RE4UIRED FOR ANY FIXTURE DOORS MAY SWING
INTO THAT PORTION OF MANEUVERING SPACE WHICH DOES NOT OVERLAP THE FIXTURE·S RE4UIRED CLEAR
FLOOR SPACE SEE FIGURES B-E C AND E
A WATER CLOSET FIXTURE LOCATED IN A COMPARTMENT SHALL PROVIDE A MINIMUM WIDE CLEAR SPACE
FROM A FIXTURE OR A MINIMUM WIDE CLEAR SPACE FROM A WALL AT ONE SIDE OF THE WATER CLOSET
THE OTHER SIDE OF THE WATER CLOSET SHALL PROVIDE FROM THE CENTERLINE OF THE WATER CLOSET
TO THE WALL GRAB BARS SHALL NOT PROJECT MORE THAN INTO THESE CLEAR SPACES THE STALL SHALL
BE MINIMUM OF WIDE
IF THE COMPARTMENT HAS A SIDE-OPENING DOOR, EITHER INS-WINGING OR OUT-SWINGING, A MINIMUM
INCHES WIDE AND INCHES DEEP MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER
CLOSET
IF THE COMPARTMENT HAS AN END-OPENING DOOR FACING THE WATER CLOSET, EITHER IN-SWINGING
OR OUT-SWINGING, A MINIMUM INCHES WIDE AND INCHES DEEP MANEUVERING SPACE SHALL BE
PROVIDED IN FRONT OF THE WATER CLOSET THE DOOR SHALL BE LOCATED IN FRONT OF THE CLEAR
FLOOR SPACE AND DIAGONAL TO THE WATER CLOSET, WITH A MAXIMUM STILE WIDTH OF INCHES
THE WATER CLOSET COMPARTMENT SHALL BE E4UIPPED WITH A DOOR THAT HAS AN AUTOMATIC-CLOSING
DEVICE, AND SHALL HAVE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF WHEN LOCATED AT THE END
AND WHEN LOCATED AT THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF DEGREES FROM ITS
CLOSED POSITION
THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE E4UIPPED WITH A LOOP OR U-SHAPED
HANDLE IMMEDIATELY BELOW THE LATCH THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING, OR OTHER
HARDWARE NOT RE4UIRING THE USER TO GRASP OR TWIST
EXCEPT FOR DOOR OPENING WIDTHS AND DOOR SWINGS, A CLEAR, UNOBSTRUCTED ACCESS NOT LESS
THAN SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS DESIGNED FOR USE BY PERSONS WITH
DISABILITIES THE SPACE IMMEDIATELY IN FRONT OF A WATER CLOSET COMPARTMENT SHALL BE NOT LESS
THAN AS MEASURED AT RIGHT ANGLES TO COMPARTMENT DOOR IN ITS CLOSED POSITION
WHERE SIX OR MORE COMPARTMENTS ARE PROVIDED WITHIN A MULTIPLE-ACCOMMODATION TOILET
ROOM, IN ADDITION TO THE WATER CLOSET AND COMPARTMENT RE4UIRED BY ITEMS AND ABOVE,
PROVIDE AT LEAST ONE AMBULATORY ACCESSIBLE COMPARTMENT THE AMBULATORY ACCESSIBLE
COMPARTMENT SHALL BE INCHES WIDE WITH AN OUTWARD SWINGING SELF-CLOSING DOOR AND
PARALLEL GRAB BARS COMPLYING WITH SECTION B, ITEM , B
PROVIDE INCHES CLEARANCE AT THE STRIKE SIDE OF WATER CLOSET COMPARTMENT DOORS NO
EXCEPTION
TOILET ROOM FLOORS SHALL HAVE A STABLE, FIRM, SLIP RESISTANT SURFACE IN COMPLIANCE WITH SECTION
B
ACCESSIBLE WATER CLOSETS
THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF AND A MAXIMUM OF
MEASURED TO THE TOP OF A MAXIMUM HIGH TOILET SEAT, EXCEPT THAT SEATS SHALL BE PERMITTED
ONLY IN ALTERATIONS WHERE THE EXISTING FIXTURE IS LESS THAN HIGH
PROVIDE CLEAR FLOOR SPACE AND MANEUVERING SPACE AT ACCESSIBLE WATER CLOSETS IN COMPLIANCE
WITH SECTION B, ITEM REFER TO SECTION B, ITEMS AND FOR ADDITIONALLY
RE4UIRED MANEUVERING SPACE AT MULTIPLE-ACCOMMODATION TOILET FACILITIES REFER TO SECTION
B, ITEM FOR ADDITIONALLY RE4UIRED MANEUVERING SPACE AT SINGLE ACCOMMODATION
TOILET FACILITIES
DWHERE A WATER CLOSET IS NOT WITHIN A WATER CLOSET COMPARTMENT, CLEAR FLOOR SPACE AROUND
THE WATER CLOSET SHALL BE INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL
CLOSEST TO THE WATER CLOSET AND INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
WALL SEE FIGURE B-E A
EWHERE A WALL MOUNTED WATER CLOSET IS INSTALLED WITHIN AN ACCESSIBLE WATER CLOSET
COMPARTMENT,CLEAR FLOOR SPACE AROUND THE WATER CLOSET SHALL BE INCHES MINIMUM
MEASURED PERPENDICULAR FROM THE SIDE WALL CLOSEST TO THE WATER CLOSET AND INCHES
MINIMUM MEASURED PERPENDICULAR FROM THE REAR WALL WHERE A FLOOR MOUNTED WATER CLOSET IS
INSTALLED WITHIN AN ACCESSIBLE WATER CLOSET COMPARTMENT, CLEAR FLOOR SPACE AROUND THE
WATER CLOSET SHALL BE INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR WALL SEE FIGURES B-E B, C, D AND
E
FWHERE A WATER CLOSET IS INSTALLED WITHIN AN ACCESSIBLE WATER CLOSET COMPARTMENT WITH AN
INSWINGING DOOR, A MINIMUM INCHES WIDE BY INCHES DEEP MANEUVERING SPACE SHALL BE
PROVIDED IN FRONT OF THE CLEAR FLOOR SPACE RE4UIRED IN ITEM SEE FIGURES B-E C AND E
ACCESSIBLE LAVATORIES
A CLEAR FLOOR SPACE BY IN FRONT OF A LAVATORY TO ALLOW A FORWARD APPROACH SUCH
CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF
INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY
LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BE A MINIMUM OF TO
THE CENTER LINE OF THE FIXTURE
ALL LAVATORIES THAT ARE DESIGNATED TO BE ACCESSIBLE SHALL BE A MINIMUM IN HORIZONTAL DEPTH
AND MOUNTED WITH THE RIM OR COUNTER EDGE NO HIGHER THAN ABOVE THE FINISHED FLOOR AND
WITH VERTICAL CLEARANCE MEASURED FROM THE BOTTOM OF THE APRON OR THE OUTSIDE BOTTOM EDGE
OF THE LAVATORY OF , REDUCING TO AT A POINT LOCATED BACK FROM THE FRONT EDGE IN
ADDITION, A MINIMUM HIGH TOE CLEARANCE MUST BE PROVIDED EXTENDING BACK TOWARD THE WALL
TO A DISTANCE NO MORE THAN FROM THE BACK WALL THE TOE CLEARANCE SPACE MUST BE FREE OF
E4UIPMENT OR OBSTRUCTIONS
HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES SHALL BE INSULATED OR OTHERWISE
COVERED THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES
ACCESSIBLE URINALS
WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR FLOOR SPACE BY IN FRONT OF
THE URINAL TO ALLOW FORWARD APPROACH
URINALS SHALL BE FLOOR MOUNTED, STALL-TYPE OR WALL HUNG WHERE ONE OR MORE WALL HUNG
URINALS ARE PROVIDED, AT LEAST ONE WITH AN ELONGATED RIM PROJECTING A MINIMUM OF FROM
THE WALL, A MAXIMUM OF FROM THE WALL, AND A MAXIMUM OF ABOVE THE FLOOR SHALL BE
PROVIDED
CONTROLS FOR WATER CLOSET FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS
AUTOMATIC SPRING TO LIFTED POSITION SEATS ARE NOT ALLOWED
WATER CLOSET AND URINAL FLUSH VALVE CONTROLS, AND FAUCET AND OPERATING MECHANISM
CONTROLS, SHALL BE OPERABLE WITH ONE HAND, SHALL NOT RE4UIRE TIGHT GRASPING, PINCHING, OR
TWISTING OF THE WRIST, AND SHALL BE MOUNTED NO MORE THAN ABOVE THE FLOOR
THE FORCE RE4UIRED TO ACTIVATE WATER CLOSET AND URINAL FLUSH VALVE CONTROLS, AND FAUCET AND
OPERATING MECHANISM CONTROLS, SHALL BE NO GREATER THAN LBF ELECTRONIC OR AUTOMATIC
FLUSHING CONTROLS ARE ACCEPTABLE AND PREFERABLE
SELF-CLOSING FAUCET CONTROL VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST
SECONDS
ALL MIRRORS LOCATED ABOVE ACCESSIBLE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE
BOTTOM EDGE OF THE REFLECTING SURFACE NO HIGHER THAN FROM THE FINISH FLOOR OR GROUND
WHEN MIRRORS ARE PROVIDED AT LOCATIONS OTHER THAN ABOVE LAVATORIES OR COUNTERTOPS, AT
LEAST ONE SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE µ MAXIMUM
ABOVE THE FINISH FLOOR OR GROUND
MIRRORS IN FITTING AND DRESSING AREAS SHALL COMPLY WITH SECTION B
IF MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER
THAN ABOVE THE FLOOR A CLEAR FLOOR SPACE BY COMPLYING WITH SECTION B SHALL
BE PROVIDED IN FRONT OF A MEDICINE CABINET TO ALLOW A FORWARD OR PARALLEL APPROACH
GRAB BARS
GRAB BARS FOR WATER CLOSETS NOT LOCATED WITHIN A COMPARTMENT SHALL COMPLY WITH SECTION
B AND SHALL BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET AND ON THE REAR
WALL
GRAB BARS FOR WATER CLOSETS LOCATED WITHIN AN ACCESSIBLE COMPARTMENT SHALL COMPLY WITH
SECTION B AND SHALL BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET AND ON
THE REAR WALL
GRAB BARS FOR WATER CLOSETS LOCATED WITHIN AMBULATORY ACCESSIBLE COMPARTMENTS SHALL
COMPLY WITH SECTION B AND SHALL BE PROVIDED ON BOTH SIDES OF THE COMPARTMENT
THE SIDE GRAB BARS SHALL BE LONG MINIMUM, LOCATED MAXIMUM FROM THE REAR WALL, AND
EXTEND MINIMUM FROM THE REAR WALL THE FRONT END SHALL BE POSITIONED MINIMUM IN FRONT
OF THE WATER CLOSET, AND SHALL BE SECURELY ATTACHED AND CENTERED ABOVE AND PARALLEL TO
THE FLOOR
THE REAR GRAB BARS SHALL BE LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
CLOSET MINIMUM ON ONE SIDE AND MINIMUM ON THE OTHER SIDE THE REAR GRAB BAR SHALL BE
SECURELY ATTACHED AND CENTERED ABOVE AND PARALLEL TO THE FLOOR, EXCEPT THAT WHERE A
TANK-TYPE TOILET IS USED, WHICH OBSTRUCTS PLACEMENT AT , THE BAR MAY BE AS HIGH AS , WITH
- MINIMUM BETWEEN THE BAR AND TOP OF TANK
THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE ô TO õ NOMINAL, OR
THE SHAPE SHALL PROVIDE AN E4UIVALENT GRIPPING SURFACE IF GRAB BARS ARE MOUNTED ADJACENT TO
A WALL, THE SPACE BETWEEN THE WALL AND THE GRAB BARS SHALL BE õ
THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS, FASTENERS, AND MOUNTING DEVICES
SHALL MEET THE FOLLOWING SPECIFICATIONS B
DBENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE
APPLICATION OF A -LB POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF
THE GRAB BAR OR SEAT
ESHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A -LB POINT LOAD SHALL BE
LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT, AND ITS
MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND
TORSIONAL SHEAR STRESSES SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS
FSHEAR FORCE INDUCED IN FASTENER OR MOUNTING DEVICES FROM THE APPLICATION OF A -LB POINT
LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING
DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD
GTENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A -LB POINT LOAD, PLUS THE
MAXIMUM MOMENT FROM THE APPLICATION OF A -LB POINT LOAD, SHALL BE LESS THAN THE
ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND SUPPORTING STRUCTURE
HGRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS
THE GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR
ABRASIVE ELEMENTS EDGES SHALL HAVE A MINIMUM RADIUS OF
ACCESSIBLE SINKS
A CLEAR FLOOR SPACE AT LEAST BY COMPLYING WITH SECTION B SHALL BE PROVIDED IN
FRONT OF A SINK TO ALLOW FORWARD APPROACH THE CLEAR FLOOR SPACE SHALL BE ON AN ACCESSIBLE
ROUTE AND SHALL EXTEND A MAXIMUM OF UNDERNEATH THE SINK
EACH ACCESSIBLE SINK SHALL BE A MAXIMUM OF - DEEP SINKS SHALL BE MOUNTED WITH THE
COUNTER OR RIM NO HIGHER THAN ABOVE THE FINISH FLOOR KNEE CLEARANCE THAT IS AT LEAST
HIGH, WIDE, AND DEEP SHALL BE PROVIDED UNDER SINKS
HOT WATER AND DRAIN PIPES EXPOSED UNDER SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED SO
AS TO PROTECT AGAINST CONTACT THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS
FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT
RE4UIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST THE FORCE RE4UIRED TO ACTIVATE
CONTROLS SHALL BE NOT GREATER THAN LBF LEVER-OPERATED, PUSH-TYPE, AND ELECTRONICALLY
CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS
SELF-CLOSING FAUCET CONTROL VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST
SECONDS
DOORS
EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL
KNOWLEDGE OR EFFORT
MANUALLY OPERATED EDGE OR SURFACE-MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED
WHEN EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF
HAVING THE AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOORKNOB OR SURFACE-MOUNTED HARDWARE
THE UNLATCHING OF ANY LEAF SHALL NOT RE4UIRED MORE THAN ONE OPERATION
LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL
BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS,
OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT RE4UIRING THE ABILITY TO GRASP THE
OPENING HARDWARE LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION
HAND ACTIVATED DOOR OPENING HARDWARE TO BE MOUNTED TO ABOVE THE FLOOR AND BE
OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE
MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED POUNDS FOR EXTERIOR DOORS AND
POUNDS FOR INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED
DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS COMPENSATING DEVICES OR
AUTOMATIC OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS WHEN FIRE DOORS ARE
RE4UIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MAXIMUM
ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED POUNDS
ONE DOOR OF A PAIR OF DOORS SHALL MEET THE MINIMUM WIDTH RE4UIREMENTS
MAXIMUM HEIGHT OF THRESHOLD TO BE MAXIMUM VERTICAL CHANGE AT EDGE IS WITH A
MAXIMUM BEVEL OF SLOPE
ALL RE4UIRED EXIT DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING WITH THE DOOR AT DEGREE
TO THE CLOSED POSITION
THERE SHALL BE A LEVEL AND CLEAR FLOOR OR LANDING ON EACH SIDE OF EXIT DOOR THE LENGTH OF
LEVEL AREA IN THE DIRECTION OF DOOR SWING SHALL BE AND IN THE OPPOSITE DIRECTION
THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND PAST THE
STRIKE EDGE OF THE DOOR FOR EXTERIOR AND PAST THE STRIKE FOR INTERIOR DOORS
PROVIDE CLEAR SPACE OF INCHES PAST STRIKE EDGE OF THE DOOR ON THE OPPOSITE SIDE TO WHICH
THE DOOR SWINGS IF THE DOOR IS E4UIPPED WITH BOTH A LATCH AND A CLOSER
THE FLOOR OR LANDING SHALL BE NOT MORE THAN INCH LOWER THAN THE THRESHOLD OF THE
DOORWAY CHANGE IN LEVEL BETWEEN INCH AND INCH SHALL BE BEVELED WITH A SLOPE NO
GREATER THAN ONE UNIT VERTICAL IN UNITS HORIZONTAL
THE BOTTOM INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH,
UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT
CREATING A TRAP OR HAZARDOUS CONDITION WHERE NARROW FRAME DOORS ARE USED, A INCH HIGH
SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE DOOR TO
BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION
THE MAXIMUM FORCE RE4UIRED TO PUSH OR PULL OPEN A DOOR SHALL COMPLY WITH THE FOLLOWING
PUSH OR PULL FORCE FOR A HINGED DOOR SHALL BE MEASURED PERPENDICULAR TO THE DOOR FACE AT
THE DOOR OPENING HARDWARE OR INCHES FROM THE HINGED SIDE, WHICHEVER IS FARTHER FROM THE
HINGE PUSH OR PULL FORCE FOR A SLIDING OR FOLDING DOOR SHALL BE MEASURED PARALLEL TO THE
DOOR AT THE DOOR PULL OR LATCH COMPENSATING DEVISES OR AUTOMATIC DOOR OPERATORS
COMPLYING WITH SECTION B MAY BE USED TO MEET THE MAXIMUM FORCE LIMITS
DRE4UIRED FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE
ADMINISTRATIVE AUTHORITY, NOT TO EXCEED LBF
EOTHER THAN RE4UIRED FIRE DOORS, INTERIOR DOORS SHALL HAVE A MAXIMUM OPENING FORCE OF
LBF
FOTHER THAN RE4UIRED FIRE DOORS, EXTERIOR DOORS SHALL HAVE A MAXIMUM OPENING FORCE OF
LBF
PURMHFW DLUHFWRU
SKHHW TLWOH
PURMHFW DHVLJQHU
PURMHFW THFK
PURMHFW NR
ISSUE DATE
EM
SP
EM
ISSUE FOR PLANCHECK
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
SKHHW NR
ISSUE DESCRIPTION
ARCHITECTENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK
B&P CODE SECTION AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION AND SECTION THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING NON-STRUCTURAL
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING NON-SEISMIC
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING
S STRUCTURAL SYSTEM COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING
ID0.3
ACCESSIBILITY NOTES
14
113
SCALE
N.T.S.ACCESSIBILITY SYMBOL
INTERNATIONAL SYMBOL OF ACCESSIBILITY DISPLAYED AT
PRIMARY ENTRANCE
SYMBOL PROPORTIONS
SCALE
1/2" = 1'-0"ACCESSIBLE DOOR CONSTRUCTION
RUBBER BUMPER
ON CHAIR
10
"
M
I
N
I
M
U
M
BO
T
T
O
M
R
A
I
L
1/
4
"
M
A
X
.
1/
2
"
M
A
X
.
AT
1
:
2
S
L
O
P
E
1 2
SCALE
NTSTYPICAL ACCESSIBLE PARKING STALL
NO
PARKING
WHEEL STOP
1.ACCESSIBLE PARKING SHALL BE PROVIDED PER CBC SECTION 11B-208. VAN
ACCESSIBLE PARKING SHALL BE PROVIDED PER CBC SECTION 11B-208.2.4.
PARKING SPACES SHALL COMPLY WITH CBC SECTION 11B-502.
2.PARKING SPACES AND ACCESS AISLES SERVING THEM SHALL COMPLY WITH
SECTION 11B-302. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE
PARKING SPACES THEY SERVE. CHANGES IN LEVEL ARE NOT PERMITTED.
3.ACCESS ISLE - THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE
STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING SURFACES SHALL NOT
BE STEEPER THAN 1:48.
4.ACCESS ROUTE - THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT
BE STEEPER THAN 1:20. THE CROSS SLOPE OF WALKING SURFACES SHALL
NOT BE STEEPER THAN 1:48.
9'-0" MIN.
12'-0" FOR VAN ACCESSIBLE
18
'
-
0
"
M
I
N
.
WHITE LETTERING
"NO PARKING" IN 12 INCH
HIGH LETTERS MIN.
STRIPES AT 36" ON CENTER
IDENTIFCATION SIGN
PER CBC SEC.
11B-502.6. REFER TO
DETAILS ON THIS SHEET
INTERNATION SYMBOL OF
ACCESSIBILITY.
SEE DETAIL 14 (SIM.)
5'-0" MIN. AT TYP. ACCESSIBLE
PARKING STALL.
EXCEPTION: 8'-0" MIN. IF 9'-0" (MIN.) VAN
ACCESSIBLE PARKING STALL IS PROVIDED
ACCESS ISLE.
REFER TO NOTES ABOVE
BLUE BORDER
4'
-
0
"
M
I
N
.
ACCESS ROUTE AS OCCURS.
SEE NOTES BELOW
3'-
0
"
3'-0"
3'-0"
SCALE
NTSEXISTING SITEPLAN/PATH OF TRAVEL - FOR INFORMATION ONLY
(E)FE
(E)FE
(E
)
F
E
(E)FE
NO
PA
R
K
I
N
G
NO
PA
R
K
I
N
G
NO
PA
R
K
I
N
G
NO
PARKING
EXISTING 444 HUNTINGTON DR.
BUILDING AND TENANT. REFER TO PLAN
FOR AREA OF WORK
EXISTING VAN
ACCESSIBLE PARKING
AND ACCESSIBLE AISLE.
SEE DETAIL 13/ID0.5
EXISTING ACCESSIBLE
PARKING AND
ACCESSIBLE AISLE, TYP.
OF (5). SEE DETAIL
13/ID0.5
PROJECT NORTH
(TRUE NORTH)
ADJACENT TENANT -
NIC
(E
)
D
R
I
V
E
W
A
Y
(E
)
L
A
N
D
S
C
A
P
E
(E
)
D
R
I
V
E
W
A
Y
(E) DRIVEWAY
HU
N
T
I
N
G
T
O
N
D
R
.
S. 5TH AVE.
(E
)
L
A
N
D
S
C
A
P
E
EX
I
S
T
I
N
G
S
I
D
E
W
A
L
K
/
P
U
B
L
I
C
W
A
Y
EXISTING ACCESSIBLE
ROUTE FROM PUBLICWAY
SCALE
NTSSIGNAGE AT H.C. PARKING STALL
STATEMENT REQUIRED BY ITEM 2
OF SECTION VII MAY BE
COMBINED WITH THIS SIGN.
BLUE REFLECTORIZED SIGN
CONSTRUCTED OF PORCELAIN
STEEL WITH BEADED TEXT OR
EQUAL
WHITE
1/ 2" RADIUS
NOTE:
1.AREA OF SIGN TO BE A MINIMUM OF
70 SQ. INCHES. DESIGNATE FOR
"VAN ACCESSIBLE" WHERE
APPROPRIATE.
2.REFER TO SIGNAGE SECTION ON
SHEET ID0.3
TO TOP OF WALKING SURFACE
WHERE APPLIES
80
"
M
I
N
.
F
O
R
F
R
E
E
S
T
A
N
D
I
N
G
36
"
M
I
N
.
F
O
R
W
A
L
L
M
O
U
N
T
E
D
SCALE
NTSSIGNAGE AT ADA PARKING STALL
1" HIGH LETTERING
1/ 2" RADIUS
NOTE:
1.AREA OF SIGN TO BE A MINIMUM
OF 70 SQ. INCHES.
2.SIGN MAY BE POLE MOUNTED OR
WALL MOUNTED.
3.REFER TO SIGNAGE SECTION ON
SHEET ID0.3
*
17"
MIN.
22
"
MI
N
.
INFO. TO BE PROVIDED PRIOR
TO FABRICATION OF SIGN.
TO TOP OF WALKING SURFACE
80
"
M
I
N
.
F
O
R
F
R
E
E
S
T
A
N
D
I
N
G
36
"
M
I
N
.
F
O
R
W
A
L
L
M
O
U
N
T
E
D
15
18
19
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024
ID0.5
EXISTING SITE PLAN/
PATH OR TRAVEL
(FOR REFERENCE ONLY)
10
19
SCALE
3/8" = 1'-0"ACCESSIBLE MOUNTING HEIGHTS
PAPER
TOWEL/
TRASH
RECEPTACLE
40
"
M
A
X
.
2'-
0
"
1'-
7
"
MA
X
.
HAND
DRYER
TOILET SEAT
COVER
DISPENSER
SANITARY
NAPKIN
DISPOSAL
TOILET
PAPER
DISPENSER
MIRROR
2'-
9
"
VARIES
GRAB BAR
SOAP
DISPENSER
SCALE
3/8" = 1'-0"ACCESSIBLE LAVATORY
48" MIN.
NOTE:
1.OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE
TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. FORCE REQUIRED TO
ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM.
2.OPERABLE PARTS SHALL NOT BE FURTHER BACK FROM THE FRONT EDGE OF THE
LAVATORY COUNTER THAN THE THE WHEEL CHAIR SPACE IS ALLOWED TO EXTEND
BELOW.
30
"
MI
N
18
"
MI
N
.
PLAN VIEWSECTION VIEW
17" MIN.
19" MAX.
9"
MI
N
.
8"MIN.
KNEE
CLR.11"
MIN.
34
"
M
A
X
.
29
"
M
I
N
.
27
"
M
I
N
.
CLEAR
FLOOR
SPACE
BOTTOM OF REFLECTIVE MIRROR
SURFACE SHALL BE AT 40" AFF
MAXIMUM HEIGHT
17" MIN.
19" MAX.
44
"
M
A
X
.
HE
I
G
H
T
O
F
OP
E
R
A
B
L
E
PA
R
T
S
KNEE CLEARANCE IS REDUCED 1"
IN DEPTH FOR 6" IN HEIGHT
BETWEEN 9" TO 27" AFF.
6"
MAX.
PROVIDE INSULATION OR
OTHER PROTECTION AT HOT
WATER SUPPLY AND DRAIN
PIPES.
SEE
NOTE 2
ABOVE
SCALE
3/8" = 1'-0"ACCESSIBLE WATER CLOSET
36" MIN.
24"MIN.12"
MIN.
33
"
-
3
6
"
33
"
-
3
6
"
17
"
-
1
9
"
7" TO 9"
WATER CLOSET FLOOR OR
WALLMOUNTED
17" TO 18"
19
"
M
I
N
.
CL
TRANSFER SIDE
SIDE WALL ELEVATION
24" MIN.
REAR WALL ELEVATION
NOTE:
1.GRAB BARS TO BE -1/4" TO 1-1/2" CLEARANCE TO FINISH
WALL.
2.GRAB BARS SHALL HAVE BACKING AND BE DESIGNED TO
SUPPORT A 250 POUND POINT LOAD.
3.FLUSH CONTROLS SHALL BE ACCESSIBLE FROM THE WIDE
SISE OF THE TOILET.
4.FLOOR TO SLOPE 1/2" PER FOOT MAX. IN ANY DIRECTION.
5.FLOOR SURFACE TO BE NON-SLIP.
1 1/2"
42" MIN.
AL
L
D
I
S
P
E
N
S
E
R
S
4
0
"
MA
X
.
T
O
H
I
G
H
E
S
T
OP
E
R
A
B
L
E
P
A
R
T
12"
MAX.
33
"
-
3
6
"
A.
F
.
F
.
T
O
T
O
P
OF
G
R
A
B
B
A
R
1-1/4"Ø TO
1-1/2"Ø
SCALE
3/8" = 1'-0"ACCESSIBLE URINAL
PLAN VIEWSECTION VIEW
48" MIN.
2'-0"
14" MIN.
1'-
0
"
SE
E
E
L
E
V
A
T
I
O
N
URINAL
PARTITION
CLEAR
FLOOR
SPACE30
"
M
I
N
.
17
"
MA
X
.
44
"
M
A
X
.
FLUSH VALVE
RIM
18
"
MI
N
.
24"
MAX.
36
"
M
I
N
.
311
SCALE
1/4" = 1'-0"EXISTING ACCESSIBLE RESTROOM PLANS (FOR INFORMATION ONLY)
EXISTING W/ ACCESSIBLE
RESTROOM IDENTIFICATION.
SEE DETAIL 9/ID0.6
30" x 48"
CLR.
(E)MEN'S
RESTROOM
-
EXISTING ACCESSIBLE
LAVATORY. SEE DETAIL 7/ID0.6
30" x 48"
CLR.
EXISTING ACCESSIBLE
LAVATORY. SEE DETAIL 7/ID0.6
EXISTING ACCESSIBLE
WATER CLOSET. SEE
DETAIL 3/ID0.6
36"5'-0" MIN.
18"
MIN.
5'-0" MIN.
7'-
5
"
9'-
8
"
EXISTING ACCESSIBLE
WATER CLOSET. SEE
DETAIL 3/ID0.6
(E)WOMEN'S
RESTROOM
-
7
SCALE
NTSACCESSIBLE RESTROOM IDENTIFICATION
58
"
M
I
N
.
A
N
D
6
0
"
M
A
X
.
FLR. FIN.
CL
18" MIN.
18
"
M
I
N
.
X:
6
0
"
M
A
X
.
(S
E
E
D
E
T
.
'
B
'
)
Y:
4
8
"
M
I
N
.
(S
E
E
D
E
T
.
'
B
'
)
EQ EQTACTILE SIGNAGE
CENTERED ON TACTILE
CHARACTERS
58
"
M
I
N
.
A
N
D
6
0
"
M
A
X
.
FLR. FIN.
CLRESTROOM
X:
6
0
"
M
A
X
.
(S
E
E
D
E
T
.
'
B
'
)
Y:
4
8
"
M
I
N
.
(S
E
E
D
E
T
.
'
B
'
)
(PLAN)
UNISEX (ELEV.)MENS/WOMENS (ELEV.)
UNISEXRESTROOM
REFER TO
GEOMETRIC SYMBOLS
REFER TO
'TACTILE/BRAILLE
SIGNAGE'
(WOMEN)
(MEN)
WITHIN 1"
L(C OF DOOR AT
EITHER SIDE)
UNISEX
RESTROOM
BASELINE OF THE
LOWEST BRAILLE
CELLS
BASELINE OF THE
HIGHEST LINE OF
RAISED
CHARACTERS
X: 60" MAX.
C OF SIGNL
TACTILE/BRAILLE SIGNAGEGEOMETRIC SYMBOLS
LC OF SIGN.
SEE DETAIL 'A'
(UNISEX)
CL
1'-
0
"
1'-
0
"
1'-0
"
1'-0"
Y: 48" MAX.
1.PICTOGRAMS NOT REQUIRED ON SYMBOLS OR TACTILE SIGNAGE.
2.GENDER SPECIFIC GEOMETRIC SYMBOLS (I.E. MEN, WOMEN) APPLY ONLY TO MULTI-ACCOMMODATION
RESTROOMS. A SANITARY FACILITY THAT IS NOT SPECIFICALLY IDENTIFIED AS FOR "MEN" OR "WOMEN"
SHALL BE IDENTIFIED AS A "UNISEX" FACILITY. THE "UNISEX" SYMBOL IS THE ONLY SPECIFIC INDICATOR
REQUIRED TO BE PROVIDED BY CHAPTER 11B FOR A TOILET FACILITY THAT IS AVAILABLE FOR USE BY ALL
INDIVIDUALS. NO PICTOGRAM, TEXT, OR BRAILLE IS REQUIRED ON THE SYMBOL.
3.PROVIDE TACTILE/BRAILLE SIGNAGE: USER SIGN STATEMENT AS - "UNISEX RESTROOM", "ALL GENDER
RESTROOM", "RESTROOM", "MEN", "WOMEN".
REFER TO
GEOMETRIC SYMBOLS
REFER TO
'TACTILE/BRAILLE
SIGNAGE'
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
ID0.6
EXISTING RESTROOMS
(FOR REFERENCE ONLY)
(E)FE
(E)FE
(E
)
F
E
(E)FE
(E)MEN'S
RESTROOM
107
(E)WOMEN'S
RESTROOM
106
EXIST.
ENTRY
116
(E)OPEN
OFFICE
-
EXIST.
OFFICE
103
EXIST.
VAULT
110
EXIST.
BREAK RM.
105
EXIST.
ATM RM.
101
EXIST.
HALLWAY
108
EXIST.
ENTRY
100
EXIST.
STORAGE
104
EXIST.
STAIRS
-
EXIST.
JAN.
109
EXIST.
VAULT
111
(E)SECURITY
HALL
112
EXIST.
SVDR
113
EXIST.
STOR.
114
EXIST.
SVDR
115
EXIST.
OFFICE
117
EXIST.
OFFICE
118
EXIST.
STOR.
118A
EXIST.
OFFICE
119
EXIST.
OFFICE
120
EXIST.
OFFICE
121
EXIST.
OFFICE
122
TELLER
102
(E)FE
(E)FE
(E
)
F
E
(E)FE
(E)MEN'S
RESTROOM
107
(E)WOMEN'S
RESTROOM
106
EXIST.
ENTRY
116
(E)OPEN
OFFICE
-
EXIST.
OFFICE
103
EXIST.
VAULT
110
EXIST.
BREAK RM.
105
EXIST.
ATM RM.
101
EXIST.
HALLWAY
108
EXIST.
ENTRY
100
EXIST.
STORAGE
104
EXIST.
STAIRS
-
EXIST.
JAN.
109
EXIST.
VAULT
111
(E)SECURITY
HALL
112
EXIST.
SVDR
113
EXIST.
STOR.
114
EXIST.
SVDR
115
EXIST.
OFFICE
117
EXIST.
OFFICE
118
EXIST.
STOR.
118A
EXIST.
OFFICE
119
EXIST.
OFFICE
120
EXIST.
OFFICE
121
EXIST.
OFFICE
122
TELLER
102
EXISTING EXTERIOR.
SEE SHEET ID0.5
EXISTING EXTERIOR.
SEE SHEET ID0.5
61'-0"
COMMON PATH OF EGRESS
(EXISITNG ATRIUM -
NIC)
(EXISITNG TENANT SPACES - NIC)
KEYNOTESSHEET NOTES OCCUPANCY ANALYSIS
1.ALL AISLES SERVING AS THE PATH OF EGRESS ACCESS IN THE MEANS OF EGRESS SYSTEMS SHALL COMPLY
WITH THE REQUIREMENTS OF THE 2022 CBC CHAPTER 10. THE MINIMUM CLEAR WIDTH OF ALL AISLES IS
44" CLEAR.
2.EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, OR SPECIAL
KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE AN APPROVED TYPE (CBC CHAPTER 10).
3.EXIT DOORS SHALL SWING IN THE DIRECTION OF PATH OF TRAVEL WHEN SERVING AN OCCUPANT LOAD
OF MORE THAN 49 OCCUPANTS (CBC CHAPTER 10).
4.TWO (2) EXITS ARE REQUIRED WHEN SERVING AN OCCUPANT LOAD OF MORE THAN 49 OCCUPANTS (CBC
CHAPTER 10).
5.THE MINIMUM CLEAR WIDTH OF A DOOR SHALL NOT BE LESS THAN 32" (CBC CHAPTER 10).
6.EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR
PURPOSES.
7.COMMON PATH OF EGRESS TRAVEL IN GROUP B SHALL BE A MAXIMUM OF 75 FEET, OR A MAXIMUM OF
100 FEET IF THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRIINKLER SYSTEM (CBC
CHAPTER 10).
8.EXIT ACCESS TRAVEL DISTANCE IN GROUP B SHALL BE A MAXIMUM OF 200 FEET OR A MAXIMUM OF 300
FEET IF THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM (CBC CHAPTER
10).
9.DEAD ENDS IN CORRIDORS IN GROUP B SHALL NOT EXCEED 20 FEET, OR 50 FEET IF THE BUILDING IS
EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM (CBC CHAPTER 10).
10.MEANS OF EGRESS SHALL BE ILLUMINATED AT A MINIMUM INTENSITY OF 1 FOOT-CANDLE AT THE FLOOR
LEVEL.
11.MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED FROM AN EMERGENCY POWER SYSTEM.
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024
EXISTING 'B' OCCUPANCY TO REMAIN, NO CHANGE OF USE.
TOTAL: 7,574 S.F. @ 150 GROSS =51 OCC.
ID0.7
OCCUPANCY & EGRESS
PLAN
SCALE :
NORTH
OCCUPANCY AND EGRESS PLAN
1/8" = 1'-0"
2
2
2
(E)FE
(E
)
F
E
(E)FE
(E)MEN'S
RESTROOM
107
(E)WOMEN'S
RESTROOM
106
EXIST.
ENTRY
116
(E)OPEN
OFFICE
-
EXIST.
OFFICE
103
EXIST.
VAULT
110
EXIST.
BREAK RM.
105
EXIST.
ATM RM.
101
EXIST.
HALLWAY
108
EXIST.
ENTRY
100
EXIST.
STORAGE
104
EXIST.
STAIRS
-
EXIST.
JAN.
109
EXIST.
VAULT
111
(E)SECURITY
HALL
112
EXIST.
SVDR
113
EXIST.
STOR.
114
EXIST.
SVDR
115
EXIST.
OFFICE
117
EXIST.
OFFICE
118
EXIST.
STOR.
118A
EXIST.
OFFICE
119
EXIST.
OFFICE
120
EXIST.
OFFICE
121
EXIST.
OFFICE
122
(E)FE
EXIST.
TELLER
102
1
2
3
3 32
2
3
2
SHEET NOTES
1.REFER TO SHEET ID0.1 FOR GENERAL DEMOLITION NOTES.
2.REFER TO PARTITION PLAN FOR EXTENT OF DEMOLITION.
3.REFER TO ENGINEER'S DRAWINGS FOR ADDITIONAL DEMOLITION SCOPE.
4.THE GENERAL CONTRACTOR SHALL VISIT AND WALK THE PROJECT SITE PRIOR TO DETERMINING THE EXTENT
OF DEMOLITION WORK TO BE DONE.
5.ALL TRADES TO INSPECT EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR TO NOTIFY
MAD OF ANY CONFLICT BETWEEN EXISTING CONDITIONS AND THE DRAWINGS.
6.THE GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING WALLS TO REMAIN WHERE DEMOLITION
OCCURS AND PREP WALLS TO RECEIVE NEW FINISHES AS INDICATED ON FINISH PLAN(S) AND/OR
SCHEDULE(S).
7.ALL DEMOLISHED DOORS, FRAMES AND DOOR HARDWARE TO BE SAVED AND STORED FOR POSSIBLE RE-USE.
8.ALL EXISTING POWER AND DATA RECEPTACLES AND ASSOCIATED WIRING ARE TO REMAIN, U.O.N. THE
GENERAL CONTRACTOR SHALL VERIFY IN THE FIELD THE LOCATION AND FUNCTIONAL CAPACITY OF ALL
EXISTING TO REMAIN OUTLETS AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE
DRAWINGS AND EXISTING CONDITIONS.
9.WHERE PARTITIONS ARE DEMOLISHED, REMOVE ALL TELEPHONE, POWER, DATA RECEPTACLES, ETC AND ALL
ASSOCIATED WIRING ALL THE WAY BACK TO THE ORIGINATING SOURCE.
10.WHERE EXISTING PLUMBING FIXTURES ARE REMOVED, CAP-OFF EXISTING PLUMBING LINES AT THE SOURCE.
11.ALL EXISTING FLOOR CORES AND ASSOCIATED WIRING NOTED TO BE REMOVED SHALL BE TERMINATED ALL
THE WAY BACK TO ITS ORIGINATING SOURCE. FILL-IN CONCRETE SLAB WHERE OUTLETS ARE REMOVED.
12.GENERAL CONTRACTOR TO VERIFY EXISTING WALL BASE HEIGHT AND SKIM WALL AS REQUIRED TO RECEIVE
NEW WALL BASE.
13.IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACKLESS, PARTITIONS, ETC.) CAUSES AN
UNEVENNESS IN SLAB, THE CONTRACTOR SHALL PATCH/REPAIR/PREP THE SLAB FOR A SMOOTH LEVEL FLOOR
TO RECEIVE NEW FLOOR FINISHES.
14.CONTRACTOR SHALL DEMO AND REMOVE ALL ABANDONED CABLING IN THE CEILING TO THE POINT OF
ORIGIN AS REQUIRED BY LOCAL GOVERNING ELECTRICAL CODES, INCLUDING BUT NOT LIMITED TO THE
FOLLOWING; PHONE CABLE, COAXIAL CABLE, TV CABLE, LOW VOLTAGE CABLE, AND CONTROL WIRING NOT
BEING UTILIZED.
15.CONTRACTOR SHALL INSTALL FILTERS IN THE MAIN RETURN HVAC TRUNK WHILE IN CONSTRUCTION.
16.CONTRACTOR SHALL PATCH AND/OR REPAIR ALL EXISTING WALLS, COLUMNS, SILLS, ETC. WHICH ARE
DAMAGED OR EFFECTED BY DEMOLITION. EXISTING PARTITIONS SHALL BE EQUAL TO NEW.
SYMBOL DESCRIPTION
KEYNOTESLEGEND
SYMBOL DESCRIPTION
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024
SCALE :
NORTH
DEMOLITION PLAN
1/8" = 1'-0"
1 DEMOLISH EXISTING GLAZING SYSTEM
ID1.0
DEMOLITION PLAN
EXISTING PARTITION TO REMAIN
SHADED AREA INDICATES PORTION OF BUILDING NOT INCLUDED IN SCOPE OF WORK
(NIC)
DENOTES EXISTING TO BE REMOVED(D)
DENOTES EXISTING TO BE ABANDONED(A)
DENOTES EXISTING TO REMAIN(E)
EXISTING DOOR TO REMAIN
EXISTING MILLWORK TO BE REMOVED
3 DEMOLISH EXISTING MILLWORK AND SECURITY GLAZING
2 EXISTING POWER/DATA AT DEMOLISHED MILLWORK TO BE SALVAGED AND MODIFIED
AS REQUIRED PER NEW MILLWORK LAYOUT. REFER TO ID2.2
(E)FE
(E)FE
(E
)
F
E
(E)FE
(E)MEN'S
RESTROOM
107
(E)WOMEN'S
RESTROOM
106
EXIST.
ENTRY
116
(E)OPEN
OFFICE
-
EXIST.
OFFICE
103
EXIST.
VAULT
110
EXIST.
BREAK RM.
105
EXIST.
ATM RM.
101
EXIST.
HALLWAY
108
EXIST.
ENTRY
100
EXIST.
STORAGE
104
EXIST.
STAIRS
-
EXIST.
JAN.
109
EXIST.
VAULT
111
(E)SECURITY
HALL
112
EXIST.
SVDR
113
EXIST.
STOR.
114
EXIST.
SVDR
115
EXIST.
OFFICE
117
EXIST.
OFFICE
118
EXIST.
STOR.
118A
EXIST.
OFFICE
119
EXIST.
OFFICE
120
EXIST.
OFFICE
121
EXIST.
OFFICE
122
TELLER
102
1
ID4.0
2
ID4.0
1
D1
5'-
5
"
7'-
6
"
3'-7
"
15'-1"7'-8"2'-8"
1'-
1
"
5'-
1
1
"
1
2
'
-
0
"
1'-8"
5'-
0
"
8'
-
6
"
5'-0"
5'-0"
2'-0"
5'-
0
"
D1
D1
D1
D1
D1
2'-1"
D1
1
2
2
SHEET NOTES LEGEND
SYMBOL DESCRIPTION DETAIL SYMBOL DESCRIPTION DETAIL 1.REFER TO SHEET ID0.1 FOR GENERAL PARTITION NOTES.
2.ALL NEW PARTITIONS SHALL BE TYPE "D1", U.O.N.
3.ALL WORK SHALL BE CONSTRUCTED TO FULLY COMPLY WITH LOCAL BUILDING CODES, INCLUDING
BUILDING AND SAFETY, FIRE/LIFE SAFETY AND ADA REQUIREMENTS.
4.REFER TO DETAIL 1/ID5.1 FOR TYPICAL CORNER AND JOINT DETAILS AT DRYWALL PARTITIONS
5.NOT USED.
6.PROVIDE SUPPORT BACKING AT ALL NEW AND EXISTING PARTITIONS THAT ARE TO RECEIVE NEW MILLWORK,
WALL-MOUNTED TELEVISIONS, MONITORS AND/OR MARKER BOARDS, U.O.N. ON PLAN. REFER TO DETAIL
3/ID6.0 FOR TYPICAL BRACING DETAIL.
7.ALL DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISH, U.O.N.
8.THE GENERAL CONTRACTOR SHALL VERIFY ALL ALIGNMENTS IN THE FIELD. IF MISALIGNMENT OF EXISTING
ELEMENTS SHOULD OCCUR, THE GENERAL CONTRACTOR SHALL VERIFY THE OPTION OF FURRING
PARTITION(S) AS NECESSARY TO PROVIDE THE REQUIRED ALIGNMENT.
9.WHERE ALIGNMENTS BETWEEN TWO ELEMENTS ARE CRITICAL, TOLERANCE FOR SUCH ALIGNMENT SHALL
NOT EXCEED 14" IN 10'-0".
10.REPAIR/PREP ALL EXISTING PARTITIONS, DOORS FRAMES, ETC SCHEDULED TO RECEIVE A NEW FINISH.
11.LEVEL OR "FLOAT" EXISTING FLOOR SLAB WHERE REQUIRED FOR LEVEL FINISH AND APPEARANCE.
12.GENERAL CONTRACTOR TO VERIFY EXISTING WALL BASE HEIGHT AND SKIM WALL AS REQUIRED TO RECEIVE
NEW WALL BASE.
13.PROVIDE TACTILE EXIT SIGNS AS REQUIRED BY THE INSPECTOR.
14.DOOR OPENINGS IN GYPSUM BOARD PARTITIONS NOT DIMENSIONED ARE TO BE LOCATED IN CENTER OF
ROOM OR 4" FROM ADJOINING PARTITION, U.O.N.
15.NOT USED.
16.FIRE EXTINGUISHER CABINETS (FEC) SHALL BE BUILDING STANDARD OR APPROVED EQUAL, U.O.N. (TYPICAL 6"
STUD DEPTH, TO BE VERIFIED).
17.LEVEL OR FLOAT FLOORS WHERE REQUIRED FOR LEVEL FINISH AND APPEARANCE, WHERE FURNITURE/MILLED
UNITS AND ARCHITECTURAL ELEMENT ALIGNMENTS ARE CRITICAL (I.E. @ SLIDING DOORS, FILE ENCLOSURES,
BASES AT FULL HEIGHT CLOSETS, ETC.) TOLERANCE TO BE NO MORE THAN 1/4" IN 10'-0".
KEYNOTES
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024
SCALE :
NORTH
PARTITION/PROPOSED PLAN
1/8" = 1'-0"
SHADED AREA INDICATES PORTION OF BUILDING NOT
INCLUDED IN SCOPE OF WORK (NIC)
MILLWORK
BLDG STD FIRE EXTINGUISHER CABINET. SEE DETAIL 5/ID5.1
EXISTING PARTITION TO REMAIN REFER TO SHEET ID4.0
REFER TO DETAIL 5/ID5.1EXISTING DOOR TO REMAIN
FE
FEC
BLDG STD FIRE EXTINGUISHER
D1 REFER TO DETAIL
1/ID5.0
ID2.0
PARTITION/PROPOSED
PLAN
FLOOR-TO-UNDERSIDE OF CEILING PARTITION (NON-RATED)
1 BACKING FOR MONITOR BRACKETS -
PROVIDE 16 GA. FLAT STRAP BEHIND GYP. BD., OR SUREBOARD
BACKING AT WALL AS REQUIRED. SECURE BACKING TO WALL FRAMING AS REQUIRED
2
2
2
2
2
2 WALL IN-FILL AS REQUIRED. REFER TO DETAIL 1/ID5.0 SIM.
2
2
(E)FE
(E
)
F
E
(E)FE
(E)MEN'S
RESTROOM
107
(E)WOMEN'S
RESTROOM
106
EXIST.
ENTRY
116
(E)OPEN
OFFICE
-
EXIST.
OFFICE
103
EXIST.
VAULT
110
EXIST.
BREAK RM.
105
EXIST.
ATM RM.
101
EXIST.
HALLWAY
108
EXIST.
ENTRY
100
EXIST.
STORAGE
104
EXIST.
STAIRS
-
EXIST.
JAN.
109
EXIST.
VAULT
111
(E)SECURITY
HALL
112
EXIST.
SVDR
113
EXIST.
STOR.
114
EXIST.
SVDR
115
EXIST.
OFFICE
117
EXIST.
OFFICE
118
EXIST.
STOR.
118A
EXIST.
OFFICE
119
EXIST.
OFFICE
120
EXIST.
OFFICE
121
EXIST.
OFFICE
122
TELLER
102
1
1
1
1
1
SHEET NOTES KEYNOTES LEGEND
SYMBOL DESCRIPTIONSYMBOLDESCRIPTION1.REFER TO SHEET ID0.2 FOR GENERAL REFLECTED CEILING PLAN NOTES.
2.ANY NEW SCHEDULED CEILING TYPE (E.G. A.C.T, GYP. BD.) TO BE INSTALLED TO MATCH EXISTING CEILING
HEIGHTS, U.O.N.
3.ALL LIGHT FIXTURES SHOWN ON PLAN ARE EXISTING, U.O.N.
4.ALL LIGHT SWITCHES, PROJECTION SCREEN CONTROLS, AND THERMOSTATS SHALL BE GANGED TOGETHER
WHERE POSSIBLE.
5.ALL CEILING SYSTEMS AND FIXTURES ARE TO BE SUPPORTED AND BRACED AS REQUIRED BY LOCAL
GOVERNING CODES.
6.EXTEND OR MODIFY FIRE/LIFE SAFETY SYSTEM AS REQUIRED.
7.ALL EXPOSED DATA/PHONE LINES SHALL BE IN CABLE TRAYS OR SHALL BE IN RIGID CONDUIT WHEN
CROSSING OPEN CEILING AREAS.
8.PROVIDE ADDITIONAL EXIT SIGNS AS REQUIRED BY THE FIRE INSPECTOR.
9.ALL (E) CEILING AND ASSOCIATED CEILING DEVICES ARE TO REMAIN, U.O.N.
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024
SCALE :
NORTH
REFLECTED CEILING PLAN
1/8" = 1'-0"
EXISTING GYPSUM BOARD CEILING TO REMAIN
EXISTING ACOUSTICAL CEILING TILE SYSTEM TO REMAIN
NEW GYPSUM BOARD CEILING. REFER TO SHEET id5.2
NEW ACOUSTICAL TILE CEILING SYSTEM. REFER TO SHEET id5.2
CEILING GRID: TO MATCH EXISTING, V.I.F.
CEILING TILE: TO MATCH EXISTING, V.I.F.
ID2.1
REFLECTED CEILING PLAN
1 PATCH/REPAIR OR REPLACE ACT & GRID OR DRYWALL CEILING AS REQUIRED, TO MATCH EXISTING
2
2
2
2
(E)FE
(E)FE
(E
)
F
E
(E)FE
(E)MEN'S
RESTROOM
107
(E)WOMEN'S
RESTROOM
106
EXIST.
ENTRY
116
(E)OPEN
OFFICE
-
EXIST.
OFFICE
103
EXIST.
VAULT
110
EXIST.
BREAK RM.
105
EXIST.
ATM RM.
101
EXIST.
HALLWAY
108
EXIST.
ENTRY
100
EXIST.
STORAGE
104
EXIST.
STAIRS
-
EXIST.
JAN.
109
EXIST.
VAULT
111
(E)SECURITY
HALL
112
EXIST.
SVDR
113
EXIST.
STOR.
114
EXIST.
SVDR
115
EXIST.
OFFICE
117
EXIST.
OFFICE
118
EXIST.
STOR.
118A
EXIST.
OFFICE
119
EXIST.
OFFICE
120
EXIST.
OFFICE
121
EXIST.
OFFICE
122
TELLER
102
+74
"
+36
"
+36
"
+3
6
"
1
1
1
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024SHEET NOTES
1.REFER TO SHEET ID0.1 FOR GENERAL DEMOLITION NOTES.
2.REFER TO PARTITION PLAN FOR EXTENT OF DEMOLITION.
3.REFER TO ENGINEER'S DRAWINGS FOR ADDITIONAL DEMOLITION SCOPE.
4.THE GENERAL CONTRACTOR SHALL VISIT AND WALK THE PROJECT SITE PRIOR TO DETERMINING THE EXTENT
OF DEMOLITION WORK TO BE DONE.
5.ALL TRADES TO INSPECT EXISTING SITE CONDITIONS PRIOR TO SUBMITTING BIDS. CONTRACTOR TO NOTIFY
MAD OF ANY CONFLICT BETWEEN EXISTING CONDITIONS AND THE DRAWINGS.
6.THE GENERAL CONTRACTOR SHALL PATCH AND REPAIR EXISTING WALLS TO REMAIN WHERE DEMOLITION
OCCURS AND PREP WALLS TO RECEIVE NEW FINISHES AS INDICATED ON FINISH PLAN(S) AND/OR
SCHEDULE(S).
7.ALL DEMOLISHED DOORS, FRAMES AND DOOR HARDWARE TO BE SAVED AND STORED FOR POSSIBLE RE-USE.
8.ALL EXISTING POWER AND DATA RECEPTACLES AND ASSOCIATED WIRING ARE TO REMAIN, U.O.N. THE
GENERAL CONTRACTOR SHALL VERIFY IN THE FIELD THE LOCATION AND FUNCTIONAL CAPACITY OF ALL
EXISTING TO REMAIN OUTLETS AND NOTIFY THE DESIGNER OF ANY DISCREPANCIES BETWEEN THE
DRAWINGS AND EXISTING CONDITIONS.
9.WHERE PARTITIONS ARE DEMOLISHED, REMOVE ALL TELEPHONE, POWER, DATA RECEPTACLES, ETC AND ALL
ASSOCIATED WIRING ALL THE WAY BACK TO THE ORIGINATING SOURCE.
10.WHERE EXISTING PLUMBING FIXTURES ARE REMOVED, CAP-OFF EXISTING PLUMBING LINES AT THE SOURCE.
11.ALL EXISTING FLOOR CORES AND ASSOCIATED WIRING NOTED TO BE REMOVED SHALL BE TERMINATED ALL
THE WAY BACK TO ITS ORIGINATING SOURCE. FILL-IN CONCRETE SLAB WHERE OUTLETS ARE REMOVED.
12.GENERAL CONTRACTOR TO VERIFY EXISTING WALL BASE HEIGHT AND SKIM WALL AS REQUIRED TO RECEIVE
NEW WALL BASE.
13.IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACKLESS, PARTITIONS, ETC.) CAUSES AN
UNEVENNESS IN SLAB, THE CONTRACTOR SHALL PATCH/REPAIR/PREP THE SLAB FOR A SMOOTH LEVEL FLOOR
TO RECEIVE NEW FLOOR FINISHES.
14.CONTRACTOR SHALL DEMO AND REMOVE ALL ABANDONED CABLING IN THE CEILING TO THE POINT OF
ORIGIN AS REQUIRED BY LOCAL GOVERNING ELECTRICAL CODES, INCLUDING BUT NOT LIMITED TO THE
FOLLOWING; PHONE CABLE, COAXIAL CABLE, TV CABLE, LOW VOLTAGE CABLE, AND CONTROL WIRING NOT
BEING UTILIZED.
15.CONTRACTOR SHALL INSTALL FILTERS IN THE MAIN RETURN HVAC TRUNK WHILE IN CONSTRUCTION.
16.CONTRACTOR SHALL PATCH AND/OR REPAIR ALL EXISTING WALLS, COLUMNS, SILLS, ETC. WHICH ARE
DAMAGED OR EFFECTED BY DEMOLITION. EXISTING PARTITIONS SHALL BE EQUAL TO NEW.
SYMBOL DESCRIPTION
KEYNOTESLEGEND
SYMBOL DESCRIPTION
SCALE :
NORTH
POWER AND SIGNAL PLAN
1/8" = 1'-0"
WALL-MOUNTED STANDARD DUPLEX OUTLET
WALL-MOUNTED DEDICATED DUPLEX OUTLET
WALL-MOUNTED STANDARD QUAD OUTLET
WALL MOUNTED ELECTRICAL JUNCTION BOX
WALL-MOUNTED G.F.C.I. DUPLEX OUTLET
J
FIXT. #J WALL MOUNTED ELECTRICAL JUNCTION BOX HARDWIRED TO FIXTURE. REFER TO LIGHT
FIXTURE SCHEDULE FOR TYPE AND MILLWORK ELEVATION FOR HEIGHT.
WALL-MOUNTED DOUBLE DUPLEX DATA OUTLET W/ 3/4" CONDUIT STUBBED
TO CEILING PLENUM
1-1/4" CONDUIT FOR AV CABLING - HOMERUN
ID2.2
POWER & DATA PLAN
1 PROVIDE RECESSED CLOCK STYLE OUTLETS AT TV MONITOR LOCATION.
1
SCALE
3/8" = 1'-0"MILLWORK ELEVATION - TELLER LINE W/BRG (CUTOMER SIDE)
2'-
1
0
"
AD
A
4"
3'-
4
1
/
2
"
5'-0" TYP.
ADA TELLER STATION 17'-0"
(E
)
8
'
-
6
"
V
.
I
.
F
.
5
ID6.0
7"
MW-4
MW-1
MW-1
MW-3
MW-4
MW-1
6
ID6.0
MW-3
BULLET RESISTANT SECURITY
GLAZING BY OTHER
17'-0"
1'-4"1'-10"1'-4"1'-4"1'-4"EQ.EQ.5'-8"1'-10"
SCALE
3/8" = 1'-0"MILLWORK ELEVATION - TELLER LINE W/ BRG (TELLER SIDE)
4"
2'-0"5'-0"TYP. ADA TELLER STATION
6
ID6.0
10
'
-
0
"
5
ID6.0
17'-0"
3'-
4
1
/
2
"
1
1
/
2
"
8'-
6
"
V
E
R
I
F
Y
1'-10"
17'-0"
3'-2 1/4"5'-2"1'-10"1'-10"1'-7"
BULLET RESISTANT SECURITY
GLAZING BY OTHER
2'
-
1
0
"
AD
A
5'-0" TELLER STATION5'-0" TELLER STATION
1'-7"1'-10"
2
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024
ID4.0
INTERIOR ELEVATIONS
2
2
1SCALE
3" = 1'-0"UNDERSIDE OF CLNG GLASS PART
TY
P
E
SIZE GA
STEEL STUD
SPAC'G NOTES/REMARKSINSUL
PARTITION TYPE "D"
1 LAYER OF 5/8" THICK
TYPE "X" GYPSUM BOARD
AT EA SIDE OF STUD
GYPSUM BOARD NOTES:
1. ALL GYP BD SHEETS ARE
TO RUN VERTICALLY.
2. NO JOINTS EXCEPT AT
STUDS.
3. SEAL ALL PENETRATIONS.
4. PROVIDE
WATER-RESISTANT GYP. BD.
AT WET AREAS.
FLOOR FINISH AS
SCHEDULED
UL COMPLYING FASTENERS.
ONE AT EA SIDE OF EA
STUD
CONT UNPUNCHED 20 GA
FLOOR TRACK ANCHORED
TO SLAB
1
1
CONTINUOUS
ACCOUSTICAL SEALANT
(BOTH SIDES)
CEILING AS SCHEDULED.
REFER TO REFLECTED
CEILING PLAN
PROVIDE FRICTION-FIT
BATT INSULATION AT
PARTITION TYPE D1
METAL STUD FRAMING.
REFER TO CHART ABOVE
FOR SIZE, GAUGE AND
SPAN
CONC SLAB
WALL BASE AS SCHEDULED
FLOOR FINISH AS
SCHEDULED
DIAGONAL BRACING REFER
TO DETAIL 7/ID5.1.
ALTERNATE DIRECTION
@ 4'-0" O.C.
(2) #8 SHEET METAL
SCREW ATTACH THRU
DIAGONAL BRACING
HILTI LOW VELOCITY
POWDER DRIVEN FASTENER -
0.157 DIA X 1-1/4" EMBED
(ICC ESR 2269) @ 24" O.C.
FOR TOP CONNECTION
REFER TO DETAIL
6B/ID5.1, SIMILAR
#10 SMS ONE AT EACH
SIDE OF STUD
D1 3-5/8"20 GA 24"R8 PROVIDE INSULATION
9'-
0
"
A
.
F
.
F
.
M
A
X
.
STEEL STUDS: ICC-ESR-3064P
FACE LAYER SCREWS (FASTENERS): #6 TYPE 'S' SCREW, 1" LENGTH: 8" O.C. ON PANEL EDGES;
12" O.C. IN FIELD OF PANEL.
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
REVISION #1 10.11.2024
PLANCHECK CORRECTIONS 10.22.2024
ID5.0
CONSTRUCTION DETAILS
2
2
2
2
7 3
5
6
1
2
SCALE
N.T.S.TYPICAL CORNER/JOINT DETAIL
JOINT
END
CORNER
METAL CORNER BEAD W/ JOINT
COMPOUND & SAND SMOOTH
TAPE W/ JOINT COMPOUND & SAND SMOOTH
TAPE W/ JOINT COMPOUND & SAND SMOOTH
METAL CORNER BEAD W/ JOINT
COMPOUND & SAND SMOOTH
STAGGER JOINTS @ 24" MINIMUM
SCALE
3" = 1'-0"TYPICAL PARTITION INTERSECTION
PLAN C
PLAN A
PARTITION AS SCHEDULED
NOTE: GYPSUM BOARD IS NOT
CONTINUOUS. FILL INTERSECTION
CAVITY w/ ACOUSTICAL INSULATION
WHERE SCHEDULED
PLAN B
PLAN D
ACOUSTICAL
PARTITION AS
OCCURS
NOTE: GYPSUM
BOARD IS NOT
CONTINUOUS
SCALE
3" = 1'-0"OUTLET BOX @ PART w/ ACOUST INSUL
24" MIN
24" MIN
NOTE: SEPARATE CONDUIT
FOR OUTLET BOXES ON 2 SIDES
OF PARTITION. NO CONTACT
BETWEEN STUDS
NOTES:
1. PLACE OUTLET BOXES IN SEPARATE STUD SPACES
2. BACK-TO-BACK OUTLETS NOT PERMITTED
3. PLUG ALL UNUSED KNOCK-OUTS IN OUTLET BOXES WIT KNOCK-OUT CAPS
4. DEPTH OF OUTLET BOX MUST BE COMPATIBLE WITH STUD SIZE IN ORDER TO ACCOMMODATE BOX PAD
5. ACOUSTICAL BOX PAD REQUIREMENT APPLIES TO ALL PARTITIONS WITH ACOUSTICAL INSTALLATION
- APPLIES TO POWER, PHONE COMMUNICATIONS, ETC
TYPICAL DOUBLE STUD PARTITION WITH SOUND ISOLATION
(SIMILAR FOR STAGGERED STUDS)
TYPICAL SINGLE STUD PARTITION WITH SOUND ISOLATION
CONTINUOUS ACOUSTICAL
SEALANT AROUND ENTIRE
PERIMETER (TYP.)
TYPICAL OUTLET BOX
PARTITION AS SCHEDULED
BOX PAD
PARTITION AS SCHEDULED
SCALE
1-1/2" = 1'-0"FIRE EXTINGUISHER CAB (RATED/NR)
4'
-
0
"
A
F
F
T
O
T
O
P
O
F
C
A
B
I
N
E
T
,
U
.
O
.
N
.
ROUGH OPEN'G
VERIFY DIM.
W/ FEC SPEC
RO
U
G
H
O
P
E
N
I
N
G
VE
R
I
F
Y
W
/
S
P
E
C
I
F
I
C
A
T
I
O
N
RECESSED/ SEMI-RECESSED
FIRE EXTINGUISHER CABINET.
PROVIDE RATED CABINET AT
RATED WALLS
5/8" TYPE 'X' GYP BD AT
TOP, BOTTOM AND SIDES
OF RECESS
2 LAYERS OF 5/8" TYPE 'X'
GYP. BD.
PARTITION AS SCHEDULED.
PROVIDE 6" STUD AS
REQUIRED. REFER TO PLAN
SCALE
1 1/2" = 1'-0"METAL STUD ATTACHMENT
METAL STUDS,
TYPICAL
5/
8
"
M
A
X
.
DE
F
L
E
C
T
I
O
N
GA
P
EXISTING WOOD JOISTS
CONT 16 GA (MODEL 54)
CEMCO CST/SLIP-TRK SLOTTED
(ICC-ESR-2012)
#10 SMS ONE AT
EA. SIDE OF STUD
(2) #10 METAL TO
WOOD SCREW W/ 1/2"
MIN. EMBED @ 24" O.C.
EXISTING STRUCTURE
ABOVE
EXISTING STRUCTURE
ABOVE
METAL STUDS,
TYPICAL
EXISTING WOOD JOISTS
CONT 16 GA (MODEL 54)
CEMCO CST/SLIP-TRK SLOTTED
(ICC-ESR-2012)
SEE DETAIL BELOW FOR
TOP TRACK
ATTACHMENT TO WOOD
JOISTS
SCALE
NTSTYP. DIAGONAL BRACING DETAIL
45°
L2x2x16 GA. x 1'-0"
LONG METAL ANGLE ATTACH w/ (4) #12 SMS
212" X 20 GA METAL STUD
DIAGONAL BRACING AT 48"
OC MAX
EXISTING STRUCTURE
ABOVE
(5) #8 WOOD SCREW
W/ 1/2" MIN. EMBED @
12" O.C.
EXISTING WOOD JOISTS
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
ID5.1
CONSTRUCTION DETAILS
7 3
5
6
8
1
SCALE
NTSDIAGONAL BRACING WIRE @ WALL
#8 SELF TAPING SCREW
MIN. 4 TIGHT TURNS
1-
1
/
2
"
SPLAYED SIESMIC BRACE WIRE
600S137-54 SPAN (2) WALL STUDS MINIMUM
CONN W/ (5) #10 SMS, EA. STUD
REFER TO 3/ID6.0 FOR INLINE CONFIGURATION
OF BACKING PLATE WITH METAL STUD
1 1/2" x 1 1/2" x 12 GA x 2" CLIP ANGLE W/
(4) #12 x 1 1/4 SMS
1
0
°
T
O
4
5
°
SCALE
3" = 1'-0"EDGE DETAIL @ SUSPENDED CEILING
8" MAX
12 GA HANGER WIRE AT 2'-0"
O.C., TYPICAL
MAIN RUNNER OR
CROSS-TEE
ACOUSTICAL CEILING TILE AS
SCHEDULED
SHADOW MOLDING, TYPICAL
PARTITION AS SCHEDULED
REFER TO
BERC 2 SEISMIC CLIP
REFER TO DETAIL 5/ID5.2
34" MIN
RCP
4'-
0
"
M
A
X
.
HA
N
G
E
R
W
I
R
E
S
P
A
N
SCALE
NTSTYPICAL GYPSUM BOARD CEILING
NOTES:
1.PROVIDE LATERAL FORCE BRACING PER DETAIL 3/ID5.2, SIMILAR.
2.VERTICAL SUPPORT SHALL BE PROVIDED AS REQUIRED IN CHAPTER 47 OF THE UNIFORM BUILDING CODE,
WITH THE ADDED REQUIREMENT THAT DISCONTINUOUS ENDS OF CROSS-RUNNERS AND MAIN RUNNERS
SHALL BE VERTICALLY SUPPORTED @ 8" MAX FROM SUCH DISCONTINUITIES WHICH OCCUR WHERE CEILING IS
DISRUPTED BY A WALL.
3.PROVIDE 118" x 112" x 20 GA ANGLE AT END OF EACH STUD TO CHANNEL.
#12 GA SPLAY BRACED
WIRES. REFER TO DETAIL 6
& 7 ON THIS SHEET
8 GA VERTICAL WIRE @
4'-0" O.C. FOR
ATTACHMENT TO STRUCT.
ABOVE SEE DETAIL 6 ON
THIS SHEET
REFER TO SCHEDULE
3/ID5.2
112" 1.12 LBS/FT METAL
CHANNEL @ 4'-0" OC
METAL FURRING CLIPS OR
MIN 2 STRANDS 18 GA
WIRE TIES
1/4" MACHINE BOLT
7/8" x 26 GA GALV. METAL
FURRING CHANNEL 2'-0"
O.C.
5/8" TYPE "X" GYP. BD.
SCALE
3" = 1'-0"EDGE DETAIL @ SUSPENDED CEILING
PARTITION AS SCHEDULED
REFER TO
RCP
1 1/2" CHANNEL
GYP. BD.
7/8" MTL. FURRING
CHANNEL & CLIP
8"
9
10
11
13
14
SCALE
NTSACOUSTICAL TILE CEILING SUSPENSION
REFLECTED CEILING PLAN
NOTE:
1.PROVIDE ARMSTRONG SEISMIC RX SUSPENSION SYSTEM, ESR-1308. THIS SYSTEM ALONG WITH
DETAILS 1 THRU 7 ON THIS SHEET MEET REQUIREMENTS OF ASTM C636 AND ASCE 7.
2.PROVIDE LATERAL FORCE BRACING WHEN AREA IS GREATER THAN 1,000 SQUARE FEET.
3.PROVIDE JOINT CLIPS FOR MAIN BEAMS AND CROSS TEES WHEN CEILING AREA IS GREATER THAN
2,500 SQUARE FEET. SEE DETAIL 5/ID5.2
MAIN
RUNNERS
CROSS RUNNERS
LATERAL FORCE
BRACING AS REQUIRED
PER NOTE #2 BELOW
12 GA VERTICAL HANGER WIRE
AT 4'-0" O.C., TYP. FOR
ATTACHMENT TO STRUCTURE
ABOVE REFER TO DETAILS 6 ON
THIS SHEET
CEILING MAIN & CROSS RUNNER NOTE:
INSTALL CEILING GRID USING #12 GA
SPLAY WIRE HANGERS @ 45 DEGREES, 90
DEGREES TO EA OTHER (4 WIRES)
BEGINNING 6'-0" FROM STARTING POINT
OF GRID AND TILE LAYOUT AND IN BOTH
DIRECTIONS AT 12'-0" THEREAFTER.
ARMSTRONG SEISMIC RX
SUSPENSION SYSTEM,
UNATTACHED WALLS. SEE
DETAIL 5/ID5.2
12'-0" O.C. MAX.
COMPRESSION STRUT
6'-0"
MAX.
8" MAX.
TYP.
12
'
-
0
"
O
.
C
.
M
A
X
.
CO
M
P
R
E
S
S
I
O
N
S
T
R
U
T
6'
-
0
"
MA
X
.
COMPRESSION
STRUT, TYP. SEE
DETAIL 3/ID5.2
ARMSTRONG SEISMIC RX
SUSPENSION SYSTEM,
ATTACHED WALLS.
SEE DETAIL 5/ID5.2
CROSS RUNNER
AT 2'-0", TYP.
MAIN RUNNER
AT 4'-0", TYP.
12 GA VERTICAL
HANGER WIRE AT 4'-0".
FOR ATTACHMENT TO
STRUCTURE ABOVE
REFER TO DETAILS 6
ON THIS SHEET
PERIMETER
HANGER WIRE,
TYP.
SCALE
NTSSEISMIC BRACING DETAIL
2"
MAX.
TYP.
2-1/2" x 20 GA
4'-0"3/4" x 22 GA
3'-0"1/2" x 22 GA.
MAX. HEIGHTSIZE
COMPRESSION POST SIZE SCHEDULE
(BASED ON L/R > 200)
#12 GA SPLAY BRACED WIRES
EACH SIDE WITH MIN 3 TIGHT
TURNS IN 1-1/2" BOTH ENDS OF
WIRE, TYP. FOR ATTACHMENT TO
STRUCTURE ABOVE REFER TO
DETAILS 6 & 7 ON THIS SHEET
COMPRESSION POST &
METAL ANGLE. FOR
ATTACHMENT TO
STRUCTURE ABOVE SEE
DETAIL 11/ID5.2 SIM.
NOTE: LATERAL FORCE BRACING REQUIRED
ONLY FOR AREAS GREATER THAN 1,000 SQ.FT.
UP TO 5'-0"
4" x 20 GA UP TO 8'-0"
#12 GA SPLAY BRACED
WIRES EACH SIDE WITH MIN
3 TIGHT TURNS IN 1-1/2"
BOTH ENDS OF WIRE, TYP.
FOR ATTACHMENT TO
STRUCTURE ABOVE REFER
TO DETAILS 6 & 7 ON THIS
SHEET
STEEL STUD COMPRESSION
POST. FOR ATTACHMENT TO
STRUCTURE ABOVE SEE
DETAILS 11/ID5.2
MAIN RUNNER AT
4'-0" O.C., TYP.
CROSS-TEE AT 2'-0" O.C.
EACH WAY, TYP.
MAIN RUNNER AT
4'-0" O.C., TYP.
CROSS-TEE AT 2'-0" O.C.
EACH WAY, TYP.
4
5
°
T
Y
P
.
45°
T
Y
P
.
(2) #10 SMS
4
5
°
T
Y
P
.
45°
T
Y
P
.
#10 SMS
SCALE
NTSCEILING GRID SEISMIC BRACING DETAIL
8" MAX.BERC2
8" MAX.
3/8"
"UNATTACHED WALL" BERC2
"ATTACHED WALL" BERC2
7/8"
ARMSTRONG SEISMIC RX SUSPENSION
SYSTEMS - ESR-1308
(LARR 25032)
BERC2
7/8"
ALTERNATE
ATTATCHMENT -
POP RIVET IN LIEU OF
BERC2 SYSTEM
238"
4"
34"
112"
"MAIN BEAM JOINT CLIP"
REFER TO NOTE #3 ON 1/ID5.1
"CROSS TEE SEISMIC JOINT CLIP"
REFER TO NOTE #3 ON 1/ID5.1
CROSS TEE SEISMIC
JOINT CLIP
(SJCG & SCJSI)
MAIN BEAM SEISMIC
JOINT CLIP
(SJMR)
SCALE
3" = 1'-0"METAL STUD ATTACHMENT
2-1/2" MET. STUD
BLOCKING SCREWED TO
STRUCTURE ABOVE
CONT 20 GA TOP TRACK
w/ 2 1/2" FLANGES.
ATTACH TO MET. STUD
BLOCKING W/ #10 SMS
METAL STUDS, TYPICAL
ATTACH TO TRACK W/ #8 SMS
EA. SIDE OF EACH STUD
COPE FLANGES OF CROSS
STUD AS REQUIRED
SCALE
NTSCEILING WIRE ATTACHMENT
MIN. 2X JOIST, OR RAFTER
3"
MA
X
.
11
4"
M
I
N
.
2"
MI
N
.
3 - 1 1/2" X 9
GA STAPLES
OR THREE (3)
"STRONGHOLD"
"J" NAILS AT
EACH WIRE
AT 2X BLOCKING, PROVIDE 2 - 16d
COMMON NAILS AT EACH END
SCREW EYE AT BOTTOM OF
FRAMING MEMBER (HANGER
WIRE OR BRACING WIRE)
MIN. 1/4" DIAM. SCREW EYE W/ FULL THREAD
EMBEDMENT (1 1/4" MIN.) IN DIRECTION OF WIRE
SCREW EYE AT FACE OF
FRAMING MEMBER (BRACING
WIRE ONLY)
SCREW EYE ATTACHMENT
STAPLE OR NAIL ATTACHMENT DRILLED HOLE ATTACHMENT
BRACING WIRE
W/ MIN. 4 TIGHT
TURNS IN 1 1/2"
HANGER WIRE WITH MIN.
BRACING WIRE
W/ MIN. 4 TIGHT
TURNS IN 1 1/2"
HANGER WIRE WITH
MIN. 3 TIGHT
TURNS IN 1 1/2"
SADDLE
TIE
1/4" DIAM.
DRILLED HOLE
1"
M
I
N
.
MIN. 2X JOIST, OR RAFTER
BRACING WIRE
W/ MIN. 4 TIGHT
TURNS IN 1 1/2"
SCALE
3" = 1'-0"TRANSITION @ ACT/GYP BOARD CEIL'G
SHADOW MOULDING, TYPICAL
34" MIN
HANGER WIRE AS
REQUIRED
BERC 2 SEISMIC CLIP
SEE DET 5/id5.2
ACOUSTICAL CEILING
GRID & TILES AS OCCURS.
REFER TO REFLECTED
CEILING PLAN
GYP.BD CEILING AS
OCCURS. REFER TO
REFLECTED CEILING PLAN
6"
VA
R
I
E
S
-
SE
E
R
C
P
EXISTING CLG. HT.
REFER TO RCP
PROVIDE DIAG BRACING AS
REQ'D PER DETAIL 7/ID5.1
FOR STUD ATTACHMENT ABOVE
REFER TO DETAIL 10/ID5.2
212" x 20 GA. MTL STUD
FRAMING @ 16" O.C.
SCALE
1 1/2" = 1'-0"STRUT CONN. AT WOOD STRUCT.
OPTION 2
L 1 1/2" x 1 1/2" x 12 GA.
OR 162T125-16
WOOD STRUCTURE
ABOVE
(2) #10 SMS
2"
MIN.
OPTION 1
CUT FLANGES
AND BEND
#10 METAL TO WOOD
SCREW W/ 1/2" MIN.
EMBED @ 24" O.C.
#10 METAL TO WOOD
SCREW W/ 1/2" MIN.
EMBED @ 24" O.C.
12
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
ID5.2
CONSTRUCTION DETAILS
5
6
1
2
3
4SCALE
3" = 1'-0"CABINET DETAILS
1
1
/
2
"
1/
8
"
3"
SCHEDULED COUNTERTOP
A
DRAWER/
DOOR FACE AS SCHED.
3/4" PLYWOOD SUBSTRATE
B
C
D
SCRIBE COUNTER
TO WALL
E
F
G
WALL/CEILING LINE 1/
2
"
DRAWER/DOOR FACE
PLAS. LAM. REVEAL TO
MATCH CAB. LAMINATE
2"
DOOR FACE
UNDERCABINET LIGHT FIXTURE
AS SCHEDULED
DOOR FACE
AS OCCURS
DRAWER/
DOOR FACE AS
SCHED.
DRAWER/
DOOR FACE AS
SCHED.
DRAWER/
DOOR FACE AS
SCHED.
1/
8
"
PULL AS
SCHEDULED
PULL AS
SCHEDULED
PULL AS SCHEDULED
SEE DET. 1/id6.0
FOR ANCHOR.
SEE DET. 2/id6.0 FOR
ANCHORAGE
PULL AS
SCHEDULED
2" MIN.
SCHEDULED COUNTERTOP
3/4" PLYWOOD
SUBSTRATE
BACK SPLASH AS OCCURS.
SEE ELEVATIONS
2
5
/
8
"
SCALE
3" = 1'-0"MILLWORK BASE ANCHORAGE DETAIL
5/8"Ø EXPANSION ANCHOR, 3
@ EACH BLOCK MIN. 4" FROM
ENDS AND 4" MIN. EMBED: HILTI
KWIKBOLT III (ICBO ESR 1385)
2 X 4 WD. BLOCKING (P.T.)
PLAS. LAM. 0/ 1x WOOD FRAME
BASE W/#12 x 2" CADMIUM
PLATED F.H.W.S. @ 12" O.C.
PLAS. LAM. 0/ 3/4" MDF
DOOR/DRAWER
3"
LINE OF FINISH FLOOR
2
5
/
8
"
SCALE
3" = 1'-0"MILLWORK BASE ANCHORAGE DETAIL
PARTITION AS SCHEDULED
SECURE CABINETS TO WALL W/
#14 x 4" SCREWS INTO STUDS
OR BACKING PLATE @ 4" O.C.
MIN. 2 PER UNIT
1 x 3 @ MID-HEIGHT. TYP. @
ALL CASEWORK OVER 3'-6"
HIGH. SECURE TO FRAMING W/
2- #10 x 2" WOOD SCREWS @
4'-0" O.C.
BACKING PLATE SEE DETAIL
3/id6.0
SCALE
NTSMETAL SUPPORT BACKING
ISOMETRIC
METAL STUD FRAMING (PER
PARTITION TYPE) @ 16" OC
FOR LENGTH OF MILLWORK,
SHELVING ETC.
3 - #12 SMS @ EACH STUD
6" x 20 GA UNPUNCHED
BACKING TRACK
EXTEND BACKING TRACK ONE STUD PAST
END OF CABINET EACH END.
PROVIDE (2) 20 GA BACKING TRACKS AT
35" & 67" O.C.
4"
7"
3'
-
4
1
/
2
"
9 3/4"℄3"℄
SCALE
1" = 1'-0"TYP. TELLER DETAIL
2'
-
9
1
/
2
"
1
1
/
2
"
1/4"
1'-1"
CEILING WHERE OCCURS
1610-R S.S. DEAL TRAY
PROVIDED BY SECURITY
(2) 2-1/2" SATIN CHROME
GROMMETS AT EA. SIDE OF
TELLER
1'-11 3/4"
PENCIL DRAWER BY
MILLWORKER
3/8" UL LEVEL BULLET
RESISTANT FIBERGLASS
SHEET SANDWICHED
BETWEEN 2 LAYERS OF 3/8"
MDF EA. SIDE.
ACRYLIC SECURITY GLASS AND
VOICE BAFFLES PROVIDED BY
SECURITY VENDOR
2-1/2" SATIN CHROME
GROMMETS CUST. SIDE
MW 1
MW 4
MW 1
MW 6
10
1
/
2
"
1'-
0
"
RE
M
O
V
A
B
L
E
P
N
L
.
6"
3'-6 3/4"
4"
7"
1'-
2
"
4'-
0
"
9 3/4"℄3"℄
SCALE
1" = 1'-0"ACCESSIBLE TELLER DETAIL
2'-
3
"
1
1
/
2
"
1/4"
1'-7"
CEILING WHERE OCCURS
1610-R S.S. DEAL TRAY
PROVIDED BY SECURITY
WATERFALL EDGE
(2) 2-1/2" SATIN CHROME
GROMMETS AT EA. SIDE OF
TELLER
3 1/2"
1'-8 1/4"
4 X 2 X 3/16" PLATE
WELDED TO POST, BOLTED
TO COUNTER, TYP. ALL
POSTS
PENCIL DRAWER BY
MILLWORKER
1'-2"
3/8" UL LEVEL BULLET
RESISTANT FIBERGLASS
SHEET SANDWICHED
BETWEEN 2 LAYERS OF 3/8"
MDF EA. SIDE.
ACRYLIC SECURITY GLASS AND
VOICE BAFFLES PROVIDED BY
SECURITY VENDOR
ACRYLIC PACKAGE
EXCHANGE PROVIDED BY
SECURITY VENDOR2-1/2" SATIN CHROME
GROMMETS CUST. SIDE
MW 1
MW 4
MW 1
MW 610
1
/
2
"
1'-
0
"
RE
M
O
V
A
B
L
E
P
N
L
.
Project Director:
Sheet Title:
Project Designer:
Project Tech:
Project No:
ISSUE DATE
E.M.
S.P.
24023.300
E.M.
ISSUE FOR PLANCHECK 09.06.2024
All drawings and written material appearing herein constitute the original and
unpublished work of MAD Studio and the same may not be duplicated, used
or disclosed without the written consent of MAD Studio.
Sheet No.:
ISSUE DESCRIPTION
ARCHITECT/ENGINEER STAMP
44
4
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
WE
L
L
S
F
A
R
G
O
AR
C
A
D
I
A
HU
N
T
I
N
G
T
O
N
CLIENT
www.madstudiola.com
CITY STAMP
A CERTIFIED INTERIOR DESIGNER IS A COMPETENT DESIGN PROFESSIONAL
WHO MAY PREPARE AND SUBMIT NON-STRUCTURAL NON-SEISMIC
CONSTRUCTION DOCUMENTS AND SPECIFICATIONS TO LOCAL BUILDING
DEPARTMENTS FOR THE PURPOSES OF PLAN CHECK.
B&P CODE SECTION 5800 AND DEPARTMENT OF CONSUMER AFFAIRS
CALIFORNIA ARCHITECTS BOARD SECTION 5538:
A CERTIFIED INTERIOR DESIGNER MAY DESIGN ANY TYPE OF
NON-STRUCTURAL OR NON-SEISMIC INTERIOR SPACES CONSISTENT WITH
SECTION 5800 AND SECTION 5538. THEY MAY ENGAGE IN THE
PROGRAMMING, PLANNING, DESIGNING AND DOCUMENTING THE
CONSTRUCTION AND INSTALLATION OF NON-STRUCTURAL OR NON-SEISMIC
ELEMENTS, WITHIN THE INTERIOR SPACES OF A BUILDING. "NON-STRUCTURAL"
MEANS INTERIOR ELEMENTS THAT ARE NON-LOAD BEARING. "NON-SEISMIC"
MEANS INTERIOR ELEMENTS THAT DO NOT ASSIST IN THE SEISMIC BRACING
OF A BUILDING'S STRUCTURAL SYSTEM. COMMON NON-STRUCTURAL ITEMS
INCLUDE CEILING AND PARTITION SYSTEMS AS THESE COMPONENTS EMPLOY
NORMAL AND TYPICAL BRACING CONVENTIONS AND DO NOT ASSIST IN THE
STRUCTURAL INTEGRITY OF A BUILDING.
ID6.0
MILLWORK DETAILS