Loading...
HomeMy WebLinkAbout1045 W Huntington Dr - 2024 - BMO TIPROJECT CONTACTS CLIENT ARCHITECT STANTEC ARCHITECURE INC. 224 SOUTH MICHIGAN AVENUE, SUITE 1400 CHICAGO, IL 60604-2590 PROJECT MANAGER CONTACT: DANA RIZZO PHONE: (312) 453-7605 EMAIL: DANA.RIZZO@STANTEC.COM ARCHITECT OF RECORD CONTACT: BRIAN RENO PHONE: (312) 453-7095 EMAIL: BRIAN.RENO@STANTEC.COMBUILDING DEPARTMENT STRUCTURAL ENGINEER PROJECT INFORMATION PROJECT DESCRIPTION: TENANT IMPROVEMENT FOR A NEW RETAIL BANK BRANCH IN AN EXISTING VACANT TENANT SPACE ON 1ST FLOOR, PREVIOUSLY OCCUPIED BY A BANK. SCOPE OF WORK INCLUDES THRU-WALL ATM AND NIGHT DEPOSIT IN EXISTING OPENINGS; EXTERIOR ACCESSIBILITY IMPROVEMENTS TO THE PATH OF TRAVEL SERVING THE AREA OF ALTERATION. INSTALL ONE (1) NEW LIGHT POLE AND TWO (2) WALL PACKS TO REPLACE EXISTING WALL FIXTURES. APPLICABLE BUILDING CODES: 2022 CALIFORNIA BUILDING CODE (CBC -BASED ON 2021 IBC) 2022 CALIFORNIA EXISTING BUILDING CODE (CEBC -BASED ON 2021 IEBC) 2022 CALIFORNIA MECHANICAL CODE (CMC -BASED ON 2021 IMC) 2022 CALIFORNIA PLUMBING CODE (CPC -BASED ON 2021 IPC) 2022 CALIFORNIA FIRE CODE (CFC -BASED ON 2021 IFC) 2022 CALIFORNIA ENERGY CODE (CEC -BASED ON 2021 IECC) 2022 CALIFORNIA ELECTRICAL CODE (CEC -BASED ON 2021 NEC) 2022 CHAPTER 11B ACCESSIBILITY (CBC -BASED ON 2021 IBC) 2022 LIFE SAFETY CODE (CBC -BASED ON 2021 IBC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE CITY OF ARCADIA MUNICIPAL CODE GENERAL SITE INFORMATION APN:5777-036-002 ZONING: CO -PROFFESIONAL OFFICE FIRE PROTECTION BUILDING IS EQUIPPED WITH FIRE SPRINKLERS OCCUPANCY CLASSIFICATION (SECTION 304) EXISTING:RETAIL BANK –BUSINESS GROUP B PROPOSED:RETAIL BANK –BUSINESS GROUP B (NO CHANGE) CONSTRUCTION TYPE (CHAPTER 6) TYPE: V-B (FULLY AUTO-SPRINKLERED) OVERALL BUILDING AREA: EXISTING FIRST FLOOR (BANK): 5,400 SF EXISTING SECOND FLOOR (OFFICE): 4,682 SF (NO CHANGE) TOTAL: 10,082 SF (NO CHANGE) EXISTING BUILDING AREA TO BE RENOVATED ±5,400 SF (INTERIOR T.I. -NO AREA INCREASE) BUILDING HEIGHT (SECTION 504.3): EXISTING: 2 STORIES / LESS THAN 60'-0" (NO CHANGE) NOTE: REFER TO CODE ANALYSIS ON SHEET G-105 ABBREVIATIONS A ANNEALED AC AIR CONDITIONING ACT ACOUSTIC CEILING TILE AFF ABOVE FINISH FLOOR AHU AIR HANDLING UNIT AL ALUMINUM ASPH ASPHALT CJ CONTROL JOINT CLNG CEILING CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS CPT CARPET CT CERAMIC TILE CL CENTERLINE DBL DOUBLE DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DS DOWNSPOUT EA EACH EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATION EQ EQUAL EXIST EXISTING FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISH FLOOR FR FIRE RATED FRP FIBERGLASS REINFORCED PLASTIC GALV GALVANIZED GYP BD GYPSUM BOARD HC HANDICAP HDW HARDWARE HM HOLLOW METAL HT HEIGHT HVAC HEATING,VENTILATION, AIR CONDITIONING INSUL INSULATION MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MO MASONRY OPENING MR MOISTURE RESISTANT MTL METAL NA NOT APPLICABLE NIC NOT IN CONTRACT NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OPP OPPOSITE PF PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PT PRESSURE TREATED PTD PAINTED QT QUARRY TILE R RADIUS REBAR REINFORCING BAR REF REFERENCE REQ'D REQUIRED RO ROUGH OPENING SF STOREFRONT SB SPLASHBLOCK SIM SIMILAR SPEC SPECIFICATION SS STAINLESS STEEL STL STEEL STOR STORAGE SUSP SUSPENDED T TEMPERED TYP TYPICAL UNO UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VERT VERTICAL VIF VERIFY IN FIELD WD WOOD WP WATERPROOF WWF WELDED WIRE FABRIC BMO ABBREVIATIONS SM SERVICE MANAGER SBB SMALL BUSINESS BANKER PMB PREMIER BANKER FA FINANCIAL ADVISOR FAA FINANCIAL ADVISER ASSISTANT CMR CUSTOMER MEETING ROOM CB COUPON BOOTH BM BANK MANAGER SD VAULT SAFETY DEPOSIT VAULT RRB RETAIL RELATIONSHIP BANKER PBA PERSONAL BANKER ROLE TCR TELLER CASH RECYCLER UCS UNDER-COUNTER STEEL AB ASSOCIATE BANKER (TELLER) VICINITY MAP TRUE NORTHNOT TO SCALE PROJECT LOCATION SHEET INDEX BMO BANK N.A. CONTACT: LENNY CHOCHOLEK PHONE: (219) 201-0708 EMAIL: LENNY.CHOCHOLEK@BMO.COM BRAD YOUNG & ASSOCIATES, INC. 345 POLLASKY AVENUE CLOVIS, CA 93612 CONTACT: CHRIS WINDEN PHONE: (559)552-7208 EMAIL: CHRIS@BYAENGINEERING.COM MEP ENGINEER ROBINSON ENGINEERING INC. 19401 40TH AVENUE W, SUITE 302 LYNWOOD, WA 98036 CONTACT: SHAUN NEUBAUER PHONE: (425)330-5877 EMAIL: SNEUBAUER@ROBINSONENGINEERING.COM CITY OF ARCADIA DEVELOPMENT SERVICES - BUILDING & SAFETY 240 W HUNTINGTON DR ARCADIA, CA 91066 CONTACT: GEORGE MURAKAMI OR ERIC PAGLIOTTI* PHONE: (626)574-5416 (626)574-5413* EMAIL: GMURAKAMI@ARCADIACA.GOV EPAGLIOTTY@ARCADIACA.GOV* LANDLORD KALMANOVITZ CHARITABLE FOUNDATION 100 SHORELINE HWY, BLVD B, #395 MILL VALLEY, CA 94941 PHONE: (415) 332-0550 DEFERRED SUBMITTALS DEFERRED SUBMITTALS SHALL HAVE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD WHO SHALL REVIEW AND APPROVE THEM PRIOR TO SUBMITTAL TO THE BUILDING OFFICIAL FOR PLAN REVIEW. SUBMITTALS SHALL INCLUDE A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND APPROVED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. PROVIDE AMPLE TIME FOR THE BUILDING OFFICIAL TO REVIEW THE DOCUMENTS. A SEPARATE PLAN REVIEW AND FEE WILL BE REQUIRED FOR DEFERRED SUBMITTAL ITEMS. NO FABRICATION AND/OR INSTALLATION SHALL BE COMMENCED PRIOR TO SECURING BUILDING DEPARTMENT APPROVAL. SUBMITTALS SHALL INCLUDE (AS APPLICABLE) DRAWINGS, CALCULATIONS, DETAILS, CERTIFICATIONS, ETC. THAT SERVE TO CERTIFY/CONFIRM COMPLIANCE TO THE APPROVED CONSTRUCTION DOCUMENTS, AND SHALL BE STAMPED AND SEALED BY THE LICENSED ENGINEER/CONSULTANT AUTHORIZED TO PREPARE SUCH DOCUMENTATION. THE FOLLOWING SUBMITTALS ARE DEFERRED AND/OR UNDER SEPARATE PERMIT AND PLAN REVIEW: * FIRE ALARMS / LIFE SAFETY / FIRE SPRINKLERS (BY GC) *SITE DIRECTIONAL (WHERE REQUIRED) * EXTERIOR BUILDING SIGNAGE (BY BMO SIGNAGE VENDOR) *WALK-UP ATM SURROUND REPLACEMENT (BY BMO VENDOR) SYMBOLS X # X FINISH NAME #### ###A X KN X A-XXX ELEVATION 0'-0" PARTITION TYPE REVISION NUMBER GRID BUBBLE FINISH TAG EQUIPMENT / FURNITURE DESIGNATION ROOM TAG DOOR TAG WINDOW TAG KEYNOTE DETAIL TAG DETAIL-HORIZONTAL INTERIOR ELEVATION TAG MATCH LINE PLAN DETAIL TAG BUILDING SECTION TAG ELEVATION DATUM TAG EXTERIOR ELEVATION TAG DETAIL-VERTICAL WALL SECTION TAG X A-XXX E S W N X A-XXX X A-XXX X A-XXX X A-XXX X A-XXX A-XXX #### MILLWORK TAGM###-## BMO VENDOR CONTACTS 3M: CONTACT: HELEN BRANNIGAN PHONE: (416) 209-3185 ACUITY BRANDS (LIGHTING SUPPLIER): CONTACT: KEVIN TAGGART PHONE: (647) 625-7896 EMAIL: KEVIN.TAGGART@ACUITYBRANDS.COM ARMSTRONG: CONTACT: PAUL LUTHER PHONE: (416) 399-9302 (800) 299-0379 EMAIL: PALUTHER@ARMSTRONG.COM CAESARSTONE: CONTACT: LEA EL JAWAD PHONE: (416) 876-3714 EMAIL: LELJAWAD@CAESARSTONE.CA DIEBOLD (BANKING EQUIPMENT): CONTACT: MICHAEL "CAV" CAVENDER PHONE: (678) 435.5179 EMAIL: MICHAEL.CAVENDER@DIEBOLDNIXDORF.COM ELITE PRO SHADING SYSTEMS: CONTACT: AARON ZIMMER PHONE: (905) 660-0049 EX. 238 (416) 312-0593 EMAIL: AARON@ELITEPROSHADING.COM KANE GRAPHICAL (SIGNAGE): CONTACT: JONATHAN KANE PHONE: (773) 384-1200 EMAIL: JKANE@KANEGRAPHICAL.COM KOROSEAL: EMAIL: NA@KOROSEAL.COM MAHARAM: CONTACT: DAVID MORETTI PHONE: (416) 214-3905 EMAIL: DMORETTI@MAHARAM.COM METRO WALL COVERINGS: CONTACT: CHARLEY BINDER PHONE: (647) 524-6737 EMAIL: CBINDER@METROWALLCOVERINGS.COM MOHAWK GROUP: CONTACT: KELLY CLARKE PHONE: (365) 228-9249 EMAIL: KELLY_CLARKE@MOHAWKIND.COM OFFICE REVOLUTION (FURNITURE): CONTACT: JILL ELIAS PHONE: (708) 227-5968 EMAIL: JELIAS@OFFICE-REVOLUTION.COM OLYMPIA TILE: CONTACT: DANIELA FERORELLI PHONE: (416) 785-9555 EXT. 1264 PANOLAM: CONTACT: ADRIAN BECK PHONE: (416) 970-4912 EMAIL: ADRIAN_BECK@PANOLAM.COM POI (FURNITURE): CONTACT: KELLY BODUCH EMAIL: KBODUCH@POI.CA BMO@POI.CA SECURITAS (SECURITY): CONTACT: DON KNOWLES, SR NATIONAL ACCOUNT MANAGER PHONE: (727) 247-4348 EMAIL: DONALD.KNOWLES@SECURITAS.COM SHAW CONTRACT: CONTACT: JOHN CHAN PHONE: (416) 700-3109 EMAIL: JOHN.CHAN@SHAWINC.COM STINGRAY (AV AND MUSIC): CONTACT: ALEX KIPPS, SR PROJECT MANAGER PHONE: (514) 206-3524 EMAIL: AKIPPS@STINGRAY.COM STONE TILE: CONTACT: HENRIETTA SHENDEREY PHONE: (416) 515-9000 X233 EMAIL: HENRIETTAS@STONE-TILE.COM STRATUS (SIGNAGE): CONTACT: AMANDA HURLSTON PHONE: (216) 386-4948 EMAIL: AMANDA.HURLSTON@STRATUSUNLIMITED.COM WILSONART: CONTACT: LESLIE HUMPHREY PHONE: (614) 893-6853 EMAIL: HUMPHRL@WILSONART.COM CIVIL ENGINEER KIMLEY HORN 3801 UNIVERSITY AVE, SUITE 300 RIVERSIDE, CA 92501 CONTACT: LETICIA ALVAREZ PHONE: (951)543-9873 EMAIL: LETICIA.ALVAREZ@KIMLEY-HORN.COM THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 2 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 COVER SHEET BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 G-100 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 BMO BANK N.A. TENANT IMPROVEMENT 1045 W. HUNGTINGTON DRIVE ARCADIA, CA 91007 NOTES: 1. OWNER'S EQUIPMENT: GENERAL CONTRACTOR TO PROVIDE REQUIRED OPENINGS, ACCESS PANELS, ELECTRICAL, BLOCKING (WHERE REQUIRED), AND FINAL HOOK-UP. 2. LOW VOLTAGE CABLING, CONDUITS, FLOOR CORES/PENETRATIONS SHALL BE BY GENERAL CONTRACTOR. PATCHING AND TERMINATIONS BY BMO VENDOR(S). GENERAL CONTRACTOR TO COORDINATE REQUIREMENTS WITH BMO VENDORS AND BMO IT. 3. SIGNS BY SIGN VENDOR. 4. ALL ITEMS TO BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR, UNLESS NOTED OTHERWISE. 5. LIGHT FIXTURES TO BE SOURCED THROUGH BMO'S LIGHTING SUPPLIER (ACUITY BRANDS). SEE VENDOR CONTACTS THIS SHEET. DOOR HARDWARE (INCLUDING PERMANENT CORES AND KEYING)X YES FRAMED ARTWORK X YES FIRE PROTECTION AND SPRINKLERS X YES FINAL PROFESSIONAL CLEANING X YES RESTROOM ACCESSORIES X YES PLUMBING FIXTURES (INCLUDING WATER REFILL STATION)X YES STAFF ROOM TACKBOARD X YES STAFF ROOM APPLIANCES X YES LOLLIPOP SIGN X YES CEILING GRID AND TILES X YES LIGHT FIXTURES (SEE NOTE 5)X YES PAINTING AND WALL COVERING X YES MILLWORK X YES MEDIA SLAT WALL X YES WALL AND FLOOR TILE X YES CARPET TILE AND RESILIENT FLOORING X YES WINDOW SHADES X YES TOILET ROOM ACCESSORIES (SIGNS SEE NOTE 3)X YES BANKING EQUIPMENT (I.E. PRINTERS)X X YES INTERIOR BUILDING SIGNAGE X YES INTERIOR MURAL WALL GRAPHICS X YES SECURITY X YES SERVER RACK(S)X YES LOW VOLTAGE CABLING AND CONDUITS (SEE NOTE 2)X YES EMPLOYEE LOCKERS X YES WIRELESS ACCESS POINTS (WAPs)X YES VIDEO MONITORS / AV X YES FURNITURE X YES FILM AT DEMOUNTABLE PARTITIONS, FURNITURE, WINDOWS, AND DOORS X YES TEKNION ALTOS DEMOUNTABLE PARTITIONS X YES DRIVE-UP TUBES AND EQUIPMENT X YES UNDER COUNTER BANK EQUIPMENT X YES TELLER CASH RECYCLERS (TCRs)X YES CASH SAFE(S)X YES SAFE DEPOSIT BOXES (EXISTING VAULT)X YES WALK-UP ATM AND SURROUND X YES CHEVRON MAT X YES FIRE EXTINGUISHER CABINETS / FIRE EXTINGUISHERS X YES EXTERIOR BUILDING SIGNAGE X YES MONUMENT / PYLON SIGN X YES FURNISHED / INSTALLED BY BMO VENDOR FURNISHED / INSTALLED BY GENERAL CONTRACTOR (GC) FURNISHED BY OWNER / INSTALLED BY GENERAL CONTRACTOR (GC) COORDINATED BY GENERAL CONTRACTOR (GC) RESPONSIBILITY MATRIX - OVERALL NO. DRAWING NAME 20 2 4 - 0 7 - 1 9 I S S U E D F O R D D 20 2 4 - 0 9 - 0 6 I S S U E D F O R C D R E V I E W 20 2 4 - 0 9 - 1 3 I S S U E D F O R P E R M I T A N D B I D 20 2 4 - 1 0 - 2 8 P L A N C H E C K # 2 20 2 4 - 1 1 - 1 2 P L A N C H E C K # 3 GENERAL G-100 COVER SHEET X X X X X G-101 GENERAL NOTES AND DETAILS (CA) X X X X G-102 ACCESSIBILITY DETAILS (CA)X X X X G-103 ACCESSIBILITY DETAILS (CA)X X X X G-104 ACCESSIBILITY DETAILS (CA)X X X X G-105 EGRESS PLAN AND CODE ANALYSIS X X X X X G-106 CA GREEN CODE X X X X G-107 CA GREEN CODE X X X X G-108 CA GREEN CODE X X X X G-109 OVERALL SITE PLAN X X X X X CIVIL C1.1 DEMOLITION PLAN X X X X C2.0 IMPROVEMENT PLAN X X X X C3.0 CONSTRUCTION DETAILS X X X X ARCHITECTURAL AD-100 DEMOLITION FLOOR PLAN X X X X X AD-101 DEMOLITION REFLECTED CEILING PLAN X X X X X A-100 PARTITION PLAN X X X X X A-101 REFLECTED CEILING PLAN X X X X X A-102 FINISH PLAN X X X X X A-103 FURNITURE PLAN X X X X X A-104 EQUIPMENT PLAN X X X X X A-105 POWER AND DEVICE PLAN X X X X X A-106 ROOF PLAN X X X X A-107 ROOF DETAILS X X X X A-200 EXTERIOR ELEVATIONS X X X X X A-201 INTERIOR ELEVATIONS X X X X X A-202 INTERIOR ELEVATIONS X X X X X A-203 INTERIOR ELEVATIONS X X X X X A-300 ATM / NIGHT DROP ELEVATION & DETAILS X X X X A-400 ENLARGED RESTROOM / STAFF ROOM PLANS AND ELEVATIONS X X X X X A-401 ENLARGED LAN ROOM PLANS AND DETAILS X X X X A-500 PARTITION TYPES AND GENERAL DETAILS X X X X A-501 INTERIOR DETAILS X X X X A-502 CEILING DETAILS X X X X A-503 SEISMIC DETAILS X X X X A-504 MILLWORK DETAILS X X X X A-505 MILLWORK DETAILS X X X X A-506 MEDIA SLAT WALL DETAILS X X X X A-600 DOOR SCHEDULE AND DETAILS X X X X A-601 DOOR HARDWARE SCHEDULE AND DETAILS X X X X A-602 FINISH SCHEDULE X X X X X A-603 FURNITURE SCHEDULE X X X X X A-604 LIGHT FIXTURE SCHEDULE X X X X X A-605 MILLWORK SCHEDULE X X X X X A-606 EQUIPMENT, APPLIANCE, ACCESSORIES, AND FIXTURE SCHEDULES X X X X X A-607 BANKING HALL VIEWS X X X STRUCTURAL S1.1 STANDARD NOTES X X X X S1.2 STANDARD NOTES AND DETAILS X X X X S2.1 FOUNDATION PLAN X X X X S2.2 SECOND FLOOR FRAMING PLAN X X X X S3.1 FIXTURE DETAILS X X X X S3.2 FIXTURE DETAILS X X X X MECHANICAL M000 COVER SHEET, DRAWING INDEX X X X X M001 SCHEDULES & DETAILS X X X X M100 MECHANICAL DEMO PLAN X X X X M200 HVAC PLAN X X X X M201 ROOF PLAN X X X X M300 MECHANICAL CONTROL PLAN X X X X M400 TITLE 24 X X X X M500 EQUIPMENT SPECIFICATIONS X X X X M501 EQUIPMENT SPECIFICATIONS X X X X PLUMBING P000 GENERAL NOTES & DRAWING INDEX X X X X P001 FIXTURE SCHEDULE & DETAILS X X X X P100 PLUMBING PLAN X X X X ELECTRICAL E000 LEGEND, GENERAL NOTES, INDEX X X X X E100 LIGHTING PLAN X X X X E200 POWER PLAN - MAIN X X X X E201 POWER PLAN - ROOF X X X X E300 ONE-LINE DIAGRAM & PANEL SCHEDULE X X X X E400 INTERIOR ENERGY FORMS X X X X E401 EXTERIOR ENERGY FORMS X X X X ES1 SITE LIGHTING X X X X ES2 SITE PHOTOMETRICS X X X X 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 2 PLAN CHECK #3 SS DR 2024/11/12 2 ALLL 10/28/2024 24" MIN.12" MIN. 17" - 18"FINISH FLOOR 12" MAX.42" MIN. TOILET PAPER DISPENSER FINISH FLOOR TYPICAL ELEVATION AT ACCESSIBLE TOILET TYPICAL SIDE WALL ELEVATION AT ACCESSIBLE TOILET FACE OF FINISHED WALL FACE OF FINISHED WALL GRAB BARS GRAB BARS 1 1 / 2 " M I N 1 1 / 2 " M I N . 7"-9" DI S P E N S E R O U T L E T 19 " M I N . 54" MIN. T. O . G R I P P I N G S U R F A C E 33 " - 3 6 " T. O . G R I P P I N G S U R F A C E 33 " - 3 6 " T. O . S E A T 17 " - 1 9 " 36" MIN. FLUSH CONTROLS TO BE LOCATED ON OPEN SIDE FINISH FLOOR FACE OF FINISHED WALL HO L D 9" T. O . L A V . R I M 34 " TO B . O . R E F L E C T I N G S U R F A C E 40 " M A X TYPICAL ELEVATION AT SINK / MIRROR TOILET SEAT COVER DISPENSER 40 " M A X . 40 " M A X . 44 " M A X . 60 " M A X . TOWEL DISPENSER / WASTE RECEPTACLE, SEMI RECESSED COAT HOOKS 18" MIN. TO O P E N I N G 26 " SANITARY NAPKIN DISPOSAL 24" MIN. GENERAL NOTES: GENERAL NOTES: 1. THE TERM OWNER AS USED HEREIN SHALL REFER TO 'BMO BANK N.A.' 2. THE TERM 'DESIGNER' OR 'ARCHITECT' AS USED HEREIN SHALL REFER TO 'STANTEC ARCHITECTURE' CODES AND PERMITS: 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, COUNTY AND/OR LOCAL STATUES, ORDINANCES, REGULATIONS, LAWS AND CODES WITH AMENDMENTS AS WELL AS STANDARDS OF PERFORMANCE RECOMMENDED BY MANUFACTURERS AND TRADE ASSOCIATIONS 2. ALL WORK WITHIN TO BE PERFORMED SHALL BE IN FULL COMPLIANCE WITH ALL BUILDING OWNER RULES AND REGULATIONS 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND SCHEDULING ALL REQUIRED INSPECTIONS. 4. ALL WORK CONSISTING OF INTERIOR WALLS, CEILINGS, FINISHES, AND TRIM AS SHOWN ON ALL DRAWINGS FOR THIS PROJECT TO COMPLY WITH THE REQUIREMENTS OF THE LOCAL JURISDICTION SHOP FABRICATION DRAWINGS AND SUBMITTALS: 1. PROVIDE COMPLETE SHOP DRAWINGS FOR TRADES AND MATERIALS SPECIFIED WITHIN THIS SET OF CONSTRUCTION DOCUMENTS. SUBMIT TO ARCHITECT FOR REVIEW. REFER TO MATRIX BELOW FOR MORE INFORMATION. CUTTING AND PATCHING: 1. WHERE CUTTING AND/OR CHIPPING OF STRUCTURAL SLAB IS REQUIRED, NO REBAR SHALL BE CUT WITHOUT WRITTEN APPROVAL FROM THE BUILDING OWNER AND THE DESIGNATED STRUCTURAL ENGINEER. WHERE CORE DRILLING IS REQUIRED, VERIFY EXACT LOCATIONS WITH THE DESIGNATED STRUCTURAL ENGINEER AND ARCHITECT BEFORE PROCEEDING. ADHERE TO BUILDING REGULATIONS AND GUIDELINES PRIOR TO CORE DRILLING. 2. ALL CUTTING AND PATCHING SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. ANY EXISTING FINISHES DISTURBED OR DAMAGED BY THE CONTRACTOR DURING THIS COURSE OF WORK SHALL BE REPAIRED TO MATCH EXISTING IN KIND AND FINISH AT THE CONTRACTOR'S EXPENSE. GENERAL NOTES: 1. ALL GENERAL NOTES AND NOTES APPEARING ON SHEETS SHALL BE APPLICABLE TO ALL CONSTRUCTION UNLESS NOTED OTHERWISE. SEE AND ADHERE TO ALL GENERAL NOTES AND / OR NOTES THAT APPEAR ON THE GENERAL NOTES COLUMN OF EACH SHEET OF THE CONTRACT DOCUMENTS. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS, MATERIALS, AND CONSTRUCTION. ALL SHEETS ARE TO BE REVIEWED, AND NOTES ON ANY ONE SHEET OR DRAWINGS TO BE APPLIED TO RELATED DRAWINGS AND DETAILS. 2. ALL WORK SHOWN ON THESE DOCUMENTS SHALL BE COMPLETED BY GC UNDER THE TERMS / CONDITIONS / REQUIREMENTS OF AIA DOCUMENT A201, GENERAL CONDITIONS 1997 EDITION. ALL CONTRACTOR / OWNER AGREEMENTS / CONTRACTS SHALL BE AIA DOCUMENTS 1997 EDITION. 3. SCOPE OF WORK INCLUDES PROVIDING ALL LABOR, MATERIALS, AND EQUIPMENT AS INDICATED IN CONTRACT DOCUMENTS. 4. GC SHALL SUBMIT A CRITICAL PATH SCHEDULE INDICATING MAJOR AND CRITICAL PORTIONS OF THE WORK. 5. ITEMS NOT SPECIFICALLY MENTIONED IN SPECIFICATIONS OR SHOWN IN DRAWINGS, BUT WHICH ARE INHERENTLY NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION, SHALL BE INCLUDED IN BID. 6. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED, OBTAIN CLARIFICATION FROM ARCHITECT REGARDING DESIGN INTENT. 7. ALL PLUMBING FIXTURES, DRAINS, ETC. ARE INDICATED ON MEP SHEETS UNLESS SHOWN ON ENLARGED DRAWINGS FOR CLARITY. SEE ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 8. SCOPE OF WORK INDICATED ON THESE DRAWINGS IS FOR TENANT IMPROVEMENT WORK ONLY. 9. GC TO PERFORM A PRE-CONSTRUCTION SURVEY OF ALL FINISHES ON THE SITE. PROTECT FLOOR AND WALL FINISHES PRIOR TO CONSTRUCTION. 10. GC AND EACH TRADE ARE RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NEW WORK WITH ALL EXISTING CONDITIONS AND WITH ALL OTHER TRADES. ALL DIMENSIONS SHOWN ON ARCHITECTURAL DRAWINGS SHALL BE FIELD COORDINATED WITH STRUCTURAL DRAWINGS (WHEN PRESENT) AND WORK OF PLUMBING, FIRE PROTECTION, MECHANICAL, AND ELECTRICAL TRADES. REPORT ANY AND ALL INCONSISTENCIES TO ARCHITECT PRIOR TO PROCEEDING. 11. GC TO NOTIFY ARCHITECT IMMEDIATELY IF ANY FIELD CONDITION UNCOVERED DURING CONSTRUCTION THAT IS UNFORESEEN OR INCONSISTENT WITH PLANS OR THAT WILL IMPAIR LAYOUTS OR ATTACHMENTS OF FINISHES. 12. GC IS RESPONSIBLE FOR COORDINATING THEIR WORK WITH THAT OF ANY OWNER'S OWN WORKFORCE, OWNER'S SEPARATE CONTRACTORS, AND ITEMS / WORK SUPPLIED BY OWNER FOR THE CONTRACTOR TO INSTALL. COORDINATION SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: A. INCLUDING AND MAINTAINING ANY OWNER'S WORK / ISSUES INTO PROJECT SCHEDULE B. ESTABLISHING CRITICAL DATES FOR DELIVERY, INSTALLATION, ETC. C. PROVIDE / COORDINATE HOISTING, LOADING DOCK, AND TEMPORARY SERVICES D. PROVIDE / COORDINATE ANY / ALL BLOCKING, SUPPORT, BRACING, ETC. AS REQUIRED FOR OWNER'S WORK / ISSUES. 13. FIELD VERIFY ALL DIMENSIONS CONCERNING EXISTING AND NEW WORK AND NOTIFY ARCHITECT OF CONDITIONS REQUIRING CHANGES IN DETAILS BEFORE PROCEEDING WITH FABRICATION OR INSTALLATION OF WORK. IN CASES WHERE CHANGES IN DETAILS ARE NEEDED, THESE DRAWINGS SHALL BE USED TO SHOW THE DESIGN INTENT ONLY. ANY ADDITIONAL WORK, MATERIALS, DEMOLITION, AND / OR REMOVAL AS A RESULT OF FAILURE TO COORDINATE CHANGES NECESSITATED BY FIELD CONDITIONS WITH ARCHITECT WILL BE DONE AT GC'S EXPENSE. 14. SEE ALL ENGINEERING AND / OR CONSULTANT DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION AND PROJECT REQUIREMENTS. PRIOR TO INSTALLATION OF ANY FIXTURES, EQUIPMENT, ETC., GC TO VERIFY THAT NO CONFLICTS EXISTING BETWEEN MECHANICAL, PLUMBING, ELECTRICAL, TELE/DATA, LIGHTING, FIRE-SAFETY, AND SPRINKLER SYSTEMS (INCLUDING ALL DUCT, PIPING, AND CONDUIT ROUTING) AND THAT ALL REQUIRED CLEARANCES FOR THE INSTALLATION AND MAINTENANCE OF EQUIPMENT ARE PROVIDED. VERIFY ALL LOCATIONS OF STUB-OUTS WITH ARCHITECT, AS REQUIRED. 15. SEE ALL PLAN DRAWINGS FOR DIMENSIONS, LOCATION ISSUES, ENLARGED PLAN TARGETS, ELEVATION TARGETS, DETAIL TARGETS, ETC. DIMENSIONS, TARGETS, ETC. THAT ARE TYPICAL FOR MANY AREAS ARE NOTED ONLY ONCE. ANY WORK SHOWN OR REFEREED TO ON ONE DRAWING SHALL BE PROVIDED AS THOUGH SHOWN ON ALL RELATED DRAWINGS. 16. ARCHITECTURAL DIMENSIONS AND DESIGN INTENT TAKE PRECEDENCE OVER MECHANICAL, ELECTRICAL, OR PLUMBING REQUIREMENTS. NOTIFY ARCHITECT OF ANY DISCREPANCY BEFORE PROCEEDING WITH CONSTRUCTION. IF A CONFLICT OCCURS, NOTIFY ARCHITECT FOR RESOLUTION. GENERAL NOTES (CONTINUED): 17. WHERE DESIGN INTENT CANNOT BE DETERMINED FROM CONSTRUCTION DOCUMENTS, GC IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM ARCHITECT PRIOR TO PROCEEDING WITH THE WORK IN QUESTION. 18. ALL VERTICAL DIMENSIONS SHOWN IN CONSTRUCTION DOCUMENTS ARE MEASURED FROM TOP OF FLOOR SLAB UNLESS NOTED OTHERWISE. 19. DO NOT SCALE DRAWINGS. GC IS RESPONSIBLE FOR CHECKING ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS FOR ACCURACY. IF THERE ARE ANY QUESTIONS PERTAINING TO THESE OR OTHER COORDINATION ITEMS, GC IS RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM ARCHITECT PRIOR TO PROCEEDING WITH THE WORK IN QUESTION OR RELATED WORK. 20. LARGE SCALE DETAILS TAKE PRECEDENCE OVER SMALL SCALE DETAILS. 21. GC AND ALL SUBCONTRACTORS SHALL COORDINATE AND SUBMIT TO ARCHITECT FOR DESIGN REVIEW, ALL SUBMITTALS, SAMPLES, MANUFACTURER'S LITERATURE, CATALOG CUTS, ETC. OF ANY / ALL DEVICES EXPOSED TO VIEW AND SHOULD NOT ORDER SAME WITHOUT SUCH REVIEW. ALLOW ADEQUATE TIME (MIN. 1 WEEK PER SUBMITTAL) IN CONSTRUCTION SCHEDULE FOR THIS REVIEW. GC TO FIELD MEASURE ALL CONDITIONS TO COORDINATE, FIT, AND FACILITATE SHOP DRAWING PREPARATION FOR ALL TRADES. 22. CHANGES PROPOSED BY GC IN ANY DETAIL, SYSTEM, OR MATERIAL SHALL BE PROPOSED AND SUBMITTED FOR REVIEW BY ARCHITECT AND APPROVED BY OWNER PRIOR TO SUBMISSION OF SHOP DRAWINGS, PRODUCT INFORMATION, SAMPLES, AND OTHER REQUIRED SUBMITTALS. 23. WHERE NEW WORK ADJOINS EXISTING, SUCH WORK SHALL BE PROPERLY INTEGRATED WITH EXISTING TO ENSURE UNIFORM APPEARANCE. 24. ALL AREAS WHICH RECEIVE NEW FLOOR FINISHES SHALL BE LEVELED TO A VARIANCE OF 1/4" IN 10'-0" NON-CUMULATIVE (TYP. UNO) AND PREPARED TO RECEIVE FLOOR FINISH AS SCHEDULED. 25. ALL MATERIALS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 26. NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT ARCHITECT'S PRIOR WRITTEN APPROVAL. 27. ALL DISSIMILAR METALS AND MATERIALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO AVOID GALVANIC ACTION. 28. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 29. GC IS RESPONSIBLE FOR PROVIDING, INSTALLING, AND COORDINATING ALL REQUIRED BLOCKING, BRACING, SHIMS, SUPPORT, ETC. WITHIN THE PROJECT FOR SUPPORT, ATTACHMENT, ALIGNMENT, ETC. OF ALL MILLWORK, CABINETRY, DOORS / FRAMES, EQUIPMENT, PARTITIONS, FIXTURES, TRIM, FURNITURE, APPLIED FINISHES, BASES, HARDWARE, DEVICES, PLUMBING, GLAZING SYSTEMS, CEILING SYSTEMS, OWNER'S WORK, ETC. 30. ALL EXPOSED WORK, CONSTRUCTION, MATERIALS, PRODUCTS, ETC. SHALL BE FREE OF ANY / ALL NAME PLATES, LOGOS, STAMPED OR PRINTED MARKINGS, ETC. 31. ALL CONCEALED WOOD, PLYWOOD, WOOD BLOCKING, SHIMMING, STRUCTURING, FRAMING, ETC. IS TO BE FIRE RETARDANT TREATED. 32. GC IS RESPONSIBLE FOR PROVIDING, INSTALLING, AND COORDINATING ALL FIRE STOPPING, SAFING INSULATION, FIRE PROOFING INSULATION, ETC. AS REQUIRED BY ANY / ALL CODES, LAWS, OR ANY OTHER AUTHORITY HAVING JURISDICTION AND TO MAINTAIN EXISTING FIRE RATING FOR THE FOLLOWING, BUT NOT LIMITED TO, LOCATIONS, AND / OR CONSTRUCTION: A. WALL/S BETWEEN ADJACENT TENANT SPACES WHERE THERE IS A RATED WALL ASSEMBLY B. BETWEEN FLOORS AT PENETRATIONS WHERE REQUIRED BY EXISTING OR NEW FIRE RATED FLOOR SEPARATIONS. 33. ALL LIFE SAFETY AND SECURITY DEVICES (I.E. SMOKE DETECTORS, PULL STATIONS, LIFE SAFETY SPEAKERS, FIRE ALARMS, SECURITY DEVICES / HARDWARE, CARD READERS, RELEASE BUTTONS, SPRINKLER SYSTEMS, PRE-ACTION SYSTEMS, ETC.) ARE TO BE INCORPORATED INTO THE BASE BUILDING FIRE / SECURITY AND LIFE SAFETY SYSTEMS. GENERAL CONTRACTOR TO COORDINATE OVERALL REQUIREMENTS WITH ALL TRADES AND BASE BUILDING, IF APPPLICABLE. 34. ALL DOORS USED IN CONNECTION WITH EXITS SHALL BE ARRANGED TO BE READILY OPENED, WITHOUT THE USE OF KEYS, FROM THE SIDE FROM WHICH EGRESS IS MADE PER BUILDING CODE. 35. PROVIDE FLUSH ACCESS PANELS AS REQUIRED BY ALL APPLICABLE CODES AND AS REQUIRED FOR PROPER OPERATION AND MAINTENANCE OF EQUIPMENT, CONCEALED PLUMBING SHUT OFFS, JUNCTION BOXES, AND SYSTEMS. ACCESS PANELS SHALL BE CONCEALED FROM PUBLIC VIEW IN SO FAR AS IS PRACTICAL. ACCESS PANELS REQUIRED FOR BASE BUILDING OR OWNER-PROVIDED EQUIPMENT AND CONTROLS SHALL BE COORDINATED WITH ARCHITECT. IDENTIFY ANY POTENTIAL CONFLICTS WITH REQUIRED ACCESS PANELS AND LIGHTING / MECHANICAL SYSTEMS PRIOR TO INSTALLATION OF ANY SYSTEM. 36. GC SHALL SURVEY ALL LOCATIONS AND CONDITIONS WHERE WORK IS REQUIRED TO BE ACCESSED FROM ADJACENT TENANT OR BASE BUILDING FLOORS OR SPACES (I.E. CORING FOR ELECTRICAL DEVICES, PLUMBING, ETC.) AND COORDINATE ALL SCHEDULING AND WORK WITH THE OWNER AND BUILDING MANAGEMENT. GC TO PROVIDE ALL LABOR AND MATERIALS TO REMOVE (AND REPLACE AFTER THE WORK HAS BEEN COMPLETED TO SATISFACTION) ANY AND ALL OBJECTS, FURNITURE, MATERIALS, ETC. TO GAIN ACCESS TO THE SPACES MENTIONED ABOVE AND SHALL RESTORE ANY DISTURBED AREAS TO THEIR ORIGINAL CONDITION AS ACCEPTED BY OWNER AND / OR BUILDING MANAGEMENT. 37. ARCHITECT SHALL NOT CONTROL, BE IN CHARGE OF, OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK OR FOR THE ACTS OR OMISSIONS OF THE CONTRACTORS OR ANY OTHER PERSONS PERFORMING ANY WORK OR FOR THE FAILURE OF ANY OF THEM TO CARRY OUT THE WORK. 38. VERIFY REQUIREMENTS FOR ALL EQUIPMENT INDICATED ON THE DRAWINGS. THE CONTRACTOR SHALL PROVIDE MECHANICAL, ELECTRICAL, PLUMBING AND OTHER CONNECTIONS TO BUILDING OWNER FURNITURE AND INSTALLED ITEMS. 39. GC TO COORDINATE PROVISION AND INSTALLATION OF ALL PLUMBING FIXTURES WITH MILLWORK CONTRACTOR, ELECTRICAL CONTRACTOR, DRYWALL CONTRACTOR, AND ALL OTHER TRADES AS REQUIRED. 40. PROVIDE TEMPORARY PARTITIONS AND / OR CONSTRUCTION BARRIERS (INCLUDING SIGNAGE) AS REQUIRED TO CONTAIN CONSTRUCTION ACTIVITY AND PROTECT USERS DURING CONTINUED OCCUPANCY THRU END OF CONSTRUCTION. 41. GC SHALL MAINTAIN THE PREMISES CLEAN AND FREE OF ALL TRASH DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILING, PAINT OVERSPRAY, ETC. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS, ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON COMPLETION OF THE PROJECT. CLEANING OF PROJECT SHALL TAKE PLACE PER STANDARD PRACTICES AND SPECIFIC INSTRUCTIONS FROM OWNER. ANY DAMAGE OR LOSS OF PROPERTY OCCASIONED BY OR ARISING FROM ACTS OF THE GC SHALL BE THE RESPONSIBILITY OF THE GC AND THE CONTRACTOR HEREBY INDEMNIFIES AND HOLDS HARMLESS BOTH THE OWNER AND STANTEC. UO N 1'- 6 " O . C . ELECTRICAL / LOW VOLTAGE DEVICES UO N 4" O . C . SEE ELEVATION FOR LOCATION GANG ALL DEVICES UNDER ONE PLATE UO N 4" O . C . BACKSPLASH ELECTRICAL / LOW VOLTAGE DEVICES @ MILLWORK TYPICAL DEVICE MOUNTING HEIGHT / LOCATIONS SWITCH (GANG ALL UNDER ONE PLATE) / CARD READER / AUTOMATIC PUSH PLATE / DOOR RELEASE / THERMOSTAT MA X . 4'- 0 " UON 6" PROFILE OF OPEN DOOR UON 6" MA X . 4'- 0 " ADJACENT PARTITION EQ EQ COLUMN MA X . 4'- 0 " TYPICAL DEVICE RELATIONSHIPS MA X . 4'- 0 " UON 6" CARD READER / DOOR RELEASE AUTOMATIC PUSH PLATE MA X . 4'- 0 " UON 6" SWITCH CARD READER MA X . 4'- 0 " UON 6" UON 6" SWITCH THERMOSTAT WALL MOUNTED FIRE ALARM AUDIBLE/VISUAL CEILING WALL MOUNTED EXIT SIGN LIFE SAFETY DEVICES UON 6" UO N 6'- 8 " EQ EQ 4'- 0 " WALL MOUNTED FIRE ALARM PULL STATION EQ EQ FIRE EXTINGUISHER CABINET WHERE SPECIFIED FIRE EXTINGUISHERS (SURFACE MOUNTED OR CABINET) 48 " M A X T . O . E X T I N G U I S H E R PUSH FOR ASSISTANCE 7" 3" COUPON BOOTH 7" 3" PROVIDE DARK GRAY OR BLACK BACKGROUND WITH WHITE UPPERCASE LETTERS LETTERS SHALL BE VISUAL CHARACTERS. THE HEIGHT OF THE UPPERCASE LETTER "I" SHALL BE 5/8" MINIMUM NOTE:MOUNT PER TYPICAL MOUNTING HEIGHT DETAILS IN G-SERIES SHEETS. RECEIVER PUSH BUTTON PROVIDE A LAMACOID LABEL AT THE PUSH BUTTON IN THE COUPON BOOTH. LABEL SHALL STATE "PUSH FOR ASSISTANCE". INSTALL THE LAMACOID LABEL USING TWO SIDED TAPE ABOVE THE BUTTON. PROVIDE (3) 1.5V AAA BATTERIES. PROVIDE A LAMACOID LABEL AT THE RECEIVER/CHIME AT THE TELLER LINE. LABEL SHALL STATE "COUPON BOOTH". INSTALL THE LAMACOID LABEL USING TWO SIDED TAPE ABOVE THE RECEIVER/CHIME. 20" - 25" MAX. 44 " M A X 20" MAX. 48 " M A X . 15 " M I N . 48 " M A X . OBSTRUCTED FORWARD REACH FORWARD REACH OBSTRUCTED SIDE REACH 10" - 24" MAX. 34 " M A X . 46 " M A X . MAX. 10" 34 " M A X . 48 " M A X . SIDE REACH 15 " M I N . 48 " M A X . NOTES: 1. A CLEAR FLOOR OR GROUND SPACES POSITIONED FOR A FORWARD OR A SIDE APPROACH SHALL BE PROVIDED. 2. OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES 3. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 GENERAL NOTES AND DETAILS (CA) BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 09/28/23 222702550 G-101 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE 1/2" = 1'-0"TYPICAL MOUNTING DETAILS AT ACCESSIBLE RESTROOMS (CA) 2 1/2" = 1'-0"TYPICAL MOUNTING HEIGHTS - DEVICES (CA) 1 1/2" = 1'-0"TYP. MOUNTING HEIGHTS - LIFE SAFETY (CA) 46" = 1'-0"DETAILS - INTERIOR SIGNAGE 5 SCALE SCALE 1/2" = 1'-0"ACCESSIBLE REACH RANGES 3 SCALE NOTES: 1. SHADED ITEMS ARE NOT PART OF PROJECT SCOPE. 2. SUBMITTALS LISTED ABOVE DO NOT ACCOUNT FOR ALL MATERIALS / PRODUCTS SPECIFICIED IN PROJECT. REFER TO DRAWINGS FOR COMPLETE SCOPE OF SUBMITTALS REQUIRED. 3. ALL PRODUCT SUBSTITUTIONS MUST BE REVIEWED AND APPROVED PRIOR TO CONSTRUCTION. CONTRACTOR SHALL PROVIDE REASON FOR SUBSTITUTION IN WRITING. 4. PROVIDE SIMILAR SUBMITTAL INFORMATION PACKAGED TOGETHER. DO NOT GROUP DISSIMLAR MATERIALS AND/OR PRODUCTS. FIRE PROTECTION X X LIGHTING CONTROLS X X LOW VOLTAGE X X ELECTRICAL EQUIPMENT X PLUMBING EQUIPMENT X DUCTWORK FABRICATION X X MECHANICAL EQUIPMENT X MEP: ACOUSTICAL CEILING TILE AND GRID X MILLWORK X X TACK BOARD INCLUDING HARDWARE X TILE AND GROUT X ACOUSTICAL WALL PANEL X X X WALL COVERING X X PAINT X X RESILIENT BASE X FLOOR AND WALL TRANSITIONS X X QUEUING MAT X FLOORING (WALK OFF MAT, CARPET TILE, RESILIENT AND VCT)X X CORNER GUARDS X X ROLLER WINDOW SHADES X INTERIOR FINISHES: LIGHT FIXTURES X APPLIANCES X RESTROOM ACCESSORIES X GLAZING X X DOOR, FRAMES AND HARDWARE X X WATER PROOFING MEMBRANE AND CRACK ISOLATION X STOREFRONT SYSTEM X X METAL STUDS X ARCHITECTURAL: SHOP DRAWINGS PRODUCT DATA PHYSICAL SAMPLES SUBMITTALS MATRIX SCALE ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 LC Minimum Fine $250 ACCESSIBLE VAN ONLY PARKING 48 min 30 m i n 76 2 1219 30 min 48 min 30 m i n 48 m i n 12 1 9 76 2 762 1219 36 min X > 2 4 61 0 914 60 min X > 1 5 1524 38 1 48 m i n 12 1 9 30 m i n 76 2 60 i n c h m i n . 8 0 i n c h m i n i f wi t h i n a c i r c u l a t i o n p a t h fu l l r e q u i r e d l e n g t h o f pa r k i n g s p a c e f u ll r e q u ir e d l e n g t h o f p a r k i n g s p a c e f u ll r e q u ir e d l e n g t h o f p a r k i n g s p a c e 0.2 min 5.1 0. 6 5 16 . 5 2.3-2.4 58-61 0.45-0.47 11.4-11.9 top diameter of 0.9-0.92 22.9-23.4 base diameter of℄℄2. 3 - 2 . 4 58 - 6 1 ℄ ℄ 152 15 2 27 - 8 0 27 - 8 0 12MAX. 60 m i n 24 min 36 m i n 36 min 12 min 914 305 15 2 4 610 91 4 12 min 305 60 min 1524 60 min 1524 17-25 9 229 432-635 6 max 152 30 m i n 76 2 11 min 27 m i n 68 6 203 8 min 9 min 229 30 m i n 76 2 635 25 max *11 min 27 m i n 68 6 279 203 8 min 9 min 229 73 7 29 m i n 19 min 483 279 36 m i n 48 min 1219 91 4 32 m i n 81 3 32 m i n 81 3 91 4 36 m i n 610 24 max 42 min 48 m i n 12 1 9 1067 1219 X < 48 42 min 1067 X < 48 1219 36 min 914 36 min 914 60 m i n 15 2 4 610 24 max4 max 102 X ³ 8 0 20 3 2 X > 2 7 68 6 12 max 305 12 max 305 27 - 8 0 68 6 - 2 0 3 2 27 M A X 68 6 80 m i n 20 3 2 X > 12 305 X > 12 305 27 m a x 68 6 20 3 2 X < 8 0 flared sides 1:10 max slope slope slope 4 8 min 121 9 610 24 min 610 24 min 60 min 1524 48 m i n 12 1 9 48 m i n 12 1 9 at least as wide as curb ramp 60 min 1524 sl o p e 1: 1 2 m a x slope not to exceed1:48 in any direction 48 min 1219 6- 8 15 2 - 2 0 3 36 91 4 36 * 91 4 24 m i n 61 0 36 * 91 4 6- 8 15 2 - 2 0 3 36 91 4 sl o p e 1: 1 2 m a x sl o p e 1: 1 2 m a x slopeslope slopeslope flared sides 1:10 max slope slope not to exceed 1:48 in any direction slop e 1:12 ma x slope sl o p e flared sides 1:10 max slope 6-8 15 2-20 3 36 91 4 detect. warning shall extend 36" (in direction of travel) and shall extend full width of ramp run, less 2" max on each side. detect. warning shall extend 36" (in direction of travel) and shall extend full width of ramp run, less 2" max each side. slope 48 min 72 m i n * 18 2 8 1:12 max 1:12 max 1219 6- 8 15 2 - 2 0 3 36 * 91 4 detectable warnings shall extend the full width of the turning space at the demarcation between the street and sidewalk, less 2" max each side. 36 m i n 91 4 turning space w/ slope not to exceed 1:48 in any directions slope 48 min 1:12 max 1:12 max 1219 6- 8 15 2 - 2 0 3 36 * 91 4 36 m i n 91 4 turning space w/ slope not to exceed 1:48 in any directions 36 * 91 4 10 8 m i n * 27 4 3 *where it is technically infeasible to provide a min. 108" wide turning space the depth of the detectable warnings may be reduced to 24" min. *where it is technically infeasible to provide a min. 72" wide turning space the depth of the detectable warnings may be reduced to 24" min. slope slope detectable warnings shall extend the full width of the turning space at the demarcation between the street and sidewalk, less 2" max each side. curb ramp edge 20 1 adjoining surface max. slope *detectable warnings shall be 24" min. in depth at pedestrian islands or cut through medians that are less than 96" in length in the direction of pedestrian travel. 108 min 2473 144 min * 3658 60 min * 1524 21 6 m i n 54 8 6 2 1 6 m i n 5 4 8 6 1 4 4 m i n * 3 6 5 8 1 0 8 m i n 2 7 4 3 2 1 6 m i n 5 4 8 6 NO PARKING N O P A R K I N G car van 6 0 mi n * 1 5 2 5 carvan * EXCEPTION: VAN PARKING SPACES SHALL BE PERMITTED TO BE 108" WIDE MINIMUM WHERE THE ACCESS AISLE IS 96" WIDE MINIMUM 36 min 914 36 m i n 91 4 base ar m ar m toe clearance elevation toe clearance plan knee clearance elevation knee clearance plan knee clearance elevation @ lavatory, dining and work surfaces *at dining and work surfaces, knee clearance shall extend 19" deep minimum at 27" a.f.f. 6.4 ¼max6.4 1 2¼ ¼ 6.4 ½ 12.7 12.7 ½max 12.7 ½max 36 915 6 150 min max dimension showing English units (in inches unless otherwise specified) above the line and SI units (in millimeters unless otherwise specified) below the line dimension for small measurements direction of travel or approach boundary of clear floor space or maneuvering clearance centerline minimum maximum a permitted element or its extension a wall, floor, ceiling or other element cut in section or plan a highlighted element in elevation or plan Convention Description location zone of element, control or feature greater than> <less than 33-36 840-915 dimension showing a range with minimum - maximum less than or equal to greater than or equal to> < Convention Description 60 m i n 15 2 4 full length of vehicle pull-up space 36 min 914 17 MIN. 432 22 M I N . 55 9 6 min 6 m i n CLEAR FLOOR OR GROUND SPACE FORWARD APPROACH PARALLEL APPROACH ADDITIONAL MANEUVERING CLEARANCE FOR FORWARD APPROACH IN ALCOVE ADDITIONAL MANEUVERING CLEARANCE FOR PARALLEL APPROACH IN ALCOVE CUT THROUGH AT ISLAND CURB RAMP AT ISLAND PERPENDICULAR CURB RAMPS DIAGONAL OR CORNER TYPE CURB RAMPS PARALLEL CURB RAMPS - ONE ENTRANCE/EXIT POINT PARALLEL CURB RAMPS - TWO ENTRANCE/EXIT POINTS COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS FREE STANDING ADDITIONAL SIGN SURFACE IDENTIFICATION REQUIRED ACCESSIBLE PARKING STALLS PERPENDICULAR PARKING ANGLED PARKING ACCESSIBLE PARKING SIGN (A) ELEVATION (ENLARGED) (B) PLAN CIRCULAR TURNING SPACE T-SHAPED TURNING SPACE CLEAR WIDTH OF AN ACCESSIBLE ROUTE 180 DEGREE TURN 180 DEGREE TURN (EXCEPTION) LIMITS OF PROTRUDING OBJECTS POST-MOUNTED PROTRUDING OBJECTS VERTICAL CLEARANCES VERTICAL CHANGE IN LEVELBEVELED CHANGE IN LEVEL ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES CARPET PILE HEIGHT PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE CURB RAMPS ACCESSIBLE PARKING STALLS DETECTABLE WARNING SURFACES ENTRY AND DIRECTIONAL SIGNS TURNING SPACE/CLEAR FLOOR OR GROUND SPACE KNEE AND TOE CLEARANCE ACCESSIBLE ROUTESPROTRUDING OBJECTS AND VERTICAL CLEARANCES FLOOR OR GROUND SURFACES/CHANGES IN LEVELGRAPHIC CONVENTION FOR FIGURES PASSENGER LOADING REV 01.18.24 REV 01.18.24 4 - CLEAR FLOOR OR GROUND SPACE 11B-305 9 - CURB RAMPS 11B-406 & 11B-705 1 - GRAPHIC CONVENTION FOR FIGURES 11B-104 / 11B-106 UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT OR BY TELEPHONING BLANK SPACES SHALL BE FILLED IN WITH APPROPRIATE INFO AS A PERMANENT PART OF THE SIGN. ( ) XXX-XXXX WHITE REFLECTIVE BACKGROUND WITH 1 INCH MIN. LETTERS HATCHED LINES A MAX. OF 36 INCHES ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE SURFACE, PREFERABLY BLUE OR WHITE BLUE BORDER WHITE LETTERING, 12 INCHES HIGH MIN., VISIBLE FROM ADJACENT VEHICULAR WAY WHITE EMBLEM MUST BE LOCATED IN STALL SO THAT IT IS VISIBLE BY A TRAFFIC ENFORCEMENT OFFICER WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE. THE CENTERLINE OF THE ISA SHALL BE A MAX. OF 6 INCHES FROM THE CENTERLINE OF THE PARKING SPACE, ITS SIDES PARALLEL TO THE LENGTH OF THE PARKING SPACE, AND ITS COWER CORNER AT, OR LOWER SIDE ALIGNED WITH THE END OF THE PARKING SPACE. [11B-502.6.4.1] REV 01.18.24 INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE OR BLUE BACKGROUND. SEE COMMUNICATION ELEMENTS AND FEATURES DETAIL FOR MORE INFORMATION 'VAN ACCESSIBLE' SIGN NOTES 1. PARKING IDENTIFICATION SIGNS SHALL BE REFLECTORIZED WITH A MINIMUM AREA OF 70 SQUARE INCHES. 2. DESIGNATE FOR "VAN ACCESSIBLE" WHEN APPROPRIATE. 20, PLUS 1 FOR EACH 2 PERCENT OF TOTAL 9 8 7 6 5 4 3 2 1 1001 AND OVER 501 TO 1000 401 TO 500 301 TO 400 201 TO 300 151 TO 200 101 TO 150 76 TO 100 51 TO 75 26 TO 50 1 TO 25 IN LOT TOTAL PARKING 100 OVER 1000 REQUIRED MINIMUM NUMBER OF ACCESSIBLE SPACES VAN SPACES: FOR EVERY SIX OR FRACTION OF SIX ACCESSIBLE PARKING SPACES, AT LEAST ONE SHALL BE A VAN PARKING SPACE. [11B-208.2.3.3] SIGN SHALL BE POSTED EITHER; 1) IN A CONSPICUOUS PLACE AT EACH ENTRANCE TO AN OFF-STREET PARKING FACILITY OR 2) IMMEDIATELY ADJACENT TO ON-SITE ACCESSIBLE PARKING AND VISIBLE FROM EACH PARKING SPACE. 'MINIMUM FINE' SIGN ACCESS AISLE IDENTIFICATION SIGN INTERNATIONAL SYMBOL OF ACCESSIBILITY OPTIONAL EXTENSION OF ACCESS AISLE MARKING WHITE LETTERING, 12 INCHES HIGH MIN., VISIBLE FROM ADJACENT VEHICULAR WAY BLUE BORDER ACCESS AISLE INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE ON A BLUE BACKGROUND 10 - DETECTABLE WARNINGS 11B-247 & 11B-705 REV 01.18.24 WHERE INSTALLED IN A RADIAL PATTERN, TRUNCATED DOMES SHALL HAVE A CENTER-TO-CENTER SPACING OF 1.6" MIN TO 2.4" MAX SEE PROTRUDING OBJECTS FOR REQUIRED CLEARANCES REV 01.18.24 SEE PROTRUDING OBJECTS FOR REQUIRED CLEARANCES 8 - ENTRY AND DIRECTIONAL SIGNS 11B-216.67 - ACCESSIBLE ROUTES 11B-206, 11B-402, 11B-403 & 11B-404 6 - PROTRUDING OBJECTS AND VERTICAL CLEARANCES 11B-307 REV 01.18.24 REV O1.18.24 5 - KNEE AND TOE CLEARANCE 11B-306 REV 01.18.24 1. THE CLEAR WIDTH FOR WALKING SURFACES IN CORRIDORS SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE 44 INCHES MINIMUM. 2. THE CLEAR WIDTH OF SIDEWALKS SHALL BE 48 INCHES MINIMUM. 3. THE CLEAR WIDTH FOR AISLES SHALL BE 36 INCHES MINIMUM IF SERVING ELEMENTS ON ONLY ONE SIDE, AND 44 INCHES MINIMUM IF SERVING ELEMENTS ON BOTH SIDES. 4. THE CLEAR WIDTH FOR ACCESSIBLE ROUTES TO ACCESSIBLE TOILET COMPARTMENTS SHALL BE 44 INCHES EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS. REV 01.18.24 3 - TURNING SPACE 11B-304 2 - FLOOR OR GROUND SURFACES/CHANGES IN LEVEL 11B-302 / 11B-303 REV 01.18.24 DOMINANT DIRECTION OF TRAVEL LONG DIMENSION PERPENDICULAR TO DOMINANT DIRECTION OF TRAVEL REV 01.18.24 11 - ACCESSIBLE PARKING STALLS 11B-208 & 11B-502 12 - PASSENGER DROP-OFF & LOADING ZONES 11B-209 & 11B-503 REV 01.18.24 CURB LINE ACCESS AISLE CONNECTS DIRECTLY TO AN ACCESSIBLE ROUTE AREA TO BE MARKED THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 ACCESSIBILITY DETAILS (CA) BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 G-102 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 GENERAL: 1.DIMENSIONS:DIMENSIONS THAT ARE NOT STATED AS "MAXIMUM" OR "MINIMUM" ARE ABSOLUTE. [11B-104.1] 2.CONSTRUCTION AND MANUFACTURING TOLERANCES:ALL DIMENSIONS ARE SUBJECT TO CONVENTIONAL INDUSTRY TOLERANCES EXCEPT WHERE THE REQUIREMENT IS STATED AS A RANGE WITH SPECIFIC MINIMUM AND MAXIMUM END POINTS. [11B-103] 3.EQUIVALENT FACILITATION;NOTHING IN THESE REQUIREMENTS PREVENTS THE USE OF DESIGNS, PROJECTS, OR TECHNOLOGIES AS ALTERNATIVES TO THOSE PRESCRIBED, PROVIDED THEY RESULT IN SUBSTANTIALLY EQUIVALENT OR GREATER ACCESSIBILITY AND USABILITY. [11B-103] 4.CALCULATIONS OF PERCENTAGES:WHERE THE REQUIRED NUMBER OF ELEMENTS OR FACILITIES TO BE PROVIDED IS DETERMINED BY CALCULATIONS OF RATIOS OR PERCENTAGES AND REMAINDERS OR FRACTIONS RESULT, THE NEXT GREATER WHOLE NUMBER OF SUCH ELEMENTS OR FACILITIES SHALL BE PROVIDED. WHERE THE DETERMINATION OF THE REQUIRED SIZE OR DIMENSION OF AN ELEMENT OR FACILITY INVOLVES RATIOS OR PERCENTAGES, ROUNDING DOWN FOR VALUES LESS THAN ONE HALF SHALL BE PERMITTED. [11B-104.2] NOTES: 1. FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. 2. CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE 1/2" MAXIMUM. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND SHALL HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY WITH CHANGES IN LEVEL. 3. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 1/2" IN DIAMETER. 4. VERTICAL CHANGES IN LEVEL OF 1/4" HIGH MAXIMUM SHALL BE PERMITTED TO BE VERTICAL AND WITHOUT EDGE TREATMENT. BEVELED CHANGES IN LEVEL BETWEEN 1/4" HIGH MINIMUM AND 1/2" HIGH MAXIMUM SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2 5. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 1/2" IN DIAMETER. 6. RAMPS. CHANGES IN LEVEL GREATER THAN 1/2" HIGH SHALL BE RAMPED. NOTES: 1. FLOOR OR GROUND SURFACES OF A TURNING SPACE SHALL NOT CONTAIN CHANGES IN LEVEL, SLOPES EXCEEDING 1:48, AND DETECTABLE WARNINGS. [11B-304.2] 2. CIRCULAR SPACE: THE TURNING SPACE SHALL BE A SPACE OF 60 INCHES DIAMETER MINIMUM. THE SPACE SHALL BE PERMITTED ] TO INCLUDE KNEE AND TOE CLEARANCE. 3. EACH ARM OF THE T-SHAPED SPACE SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES MINIMUM. THE SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE ONLY AT THE END OF EITHER THE BASE OR ONE ARM. [11B-304.3.2] 4. DOORS SHALL BE PERMITTED TO SWING INTO TURNING SPACES. [11B-304.4] NOTES: 1. FOOR OR GROUND SURFACES OF A CLEAR FLOOR OR GROUND SPACE SHALL NOT CONTAIN CHANGES IN LEVEL, SLOPES EXCEEDING 1:48, AND DETECTABLE WARNINGS. [11B-305.2] 2. CLEAR FLOOR SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE, UNLESS OTHERWISE SPECIFIED. [11B-305.4] 3. THE CLEAR FLOOR SPACE SHALL BE POSITIONED FOR EITHER FORWARD OR PARALLEL APPROACH TO AN ELEMENT. [11B-305.5] 4. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND SPACE SHALL ADJOIN AN ACCESSIBLE ROUTE OR ADJOIN ANOTHER CLEAR FLOOR OR GROUND SPACE. CLEAR FLOOR OR GROUND SPACE MAY OVERLAP AN ACCESSIBLE ROUTE, UNLESS SPECIFICALLY PROHIBITED. [11B-305.6] 5. WHERE A CLEAR FLOOR OR GROUND SPACE IS LOCATED IN AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF THREE SIDES, ADDITIONAL MANEUVERING CLEARANCE COMPLYING WITH MANEUVERING CLEARANCES SHOWN ABOVE SHALL BE PROVIDED. [11B-305.7] NOTES: WHERE SPACE BENEATH AN ELEMENT IS INCLUDED AS PART OF CLEAR FLOOR OR GROUND SPACE OR TURNING SPACE, THE SPACE SHALL COMPLY WITH KNEE AND TOE CLEARANCE REQUIREMENTS. ADDITIONAL SPACE SHALL NOT BE PROHIBITED BENEATH AN ELEMENT BUT SHALL NOT BE CONSIDERED AS PART OF THE CLEAR FLOOR OR GROUND SPACE OR TURNING SPACE. [11B-306.1] GENERAL: 1. EXCEPTION: HANDRAILS SHALL BE PERMITTED TO PROTRUDE 4-1/2" MAXIMUM. 2. POST MOUNTED OBJECTS. THE SLOPING PORTIONS OF HANDRAILS SERVING STAIRS AND RAMPS SHALL NOT BE REQUIRED TO COMPLY WITH POST MOUNTED OBJECTS. 3. EDGES AND CORNERS: WHERE SIGNS OR OTHER OBJECTS ARE MOUNTED ON POSTS OR PYLONS, AND THEIR BOTTOM EDGES ARE LESS THAN 80 INCHES ABOVE THE FLOOR OR GROUND SURFACE, THE EDGES OF SUCH SIGNS AND OBJECTS SHALL BE ROUNDED OR EASED AND THE CORNERS SHALL HAVE A MINIMUM RADIUS OF 1/8 INCH. 4. GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES HIGH. THE LEADING EDGE OF SUCH GUARDRAIL OR BARRIER SHALL BE LOCATED 27 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. 5. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. 6. GUY BRACES: WHERE A GUY SUPPORT IS USED WITHIN EITHER THE WIDTH OF A CIRCULATION PATH OR 24 INCHES MAXIMUM OUTSIDE OF A CIRCULATION PATH, A VERTICAL GUY BRACE, SIDEWALK GUY OR SIMILAR DEVICE SHALL BE USED TO PREVENT A HAZARD OR AN OVERHEAD OBSTRUCTION. NOTES: 1. SITE ARRIVAL POINTS: AT LEAST ONE ACCESSIBLE ROUTE SHALL BE PROVIDED WITHIN THE SITE FROM ACCESSIBLE PARKING SPACES AND ACCESSIBLE PASSENGER LOADING ZONES, PUBLIC STREETS AND SIDEWALKS; AND PUBLIC TRANSPORTATION STOPS TO THE ACCESSIBLE BUILDING OR FACILITY ENTRANCE THEY SERVE. WHERE MORE THAN ONE ROUTE IS PROVIDED, ALL ROUTES MUST BE ACCESSIBLE. [11B-206.2.1] 2. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. EXCEPTION: AN ACCESSIBLE ROUTE SHALL NOT BE REQUIRED BETWEEN ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND ACCESSIBLE SPACES IF THE ONLY MEANS OF ACCESS BETWEEN THEM IS A VEHICULAR WAY NOT PROVIDING PEDESTRIAN ACCESS. [11B-206.2.2] 3. ENTRANCES AND EXTERIOR GROUND FLOOR EXITS SHALL BE ACCESSIBLE EXCEPTIONS: EXTERIOR GROUND FLOOR EXITS SERVING SMOKE-PROOF ENCLOSURES, STAIRWELLS, AND EXIT DOORS SERVING STAIRS ONLY SHALL NOT BE REQUIRED TO BE ON AND ACCESSIBLE ROUTE. EXITS IN EXCESS OF THOSE REQUIRED BY CHAPTER 10, AND WHICH ARE MORE THAN 24 INCHES ABOVE GRADE SHALL NOT BE REQUIRE TO BE ON AN ACCESSIBLE ROUTE. DIRECTIONAL SIGNAGE SHALL COMPLY WITH CH. 10. 4. ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS: WALKING SURFACES WITH A RUNNING SLOPE NOT STEEPER THAN 1:20, DOORWAYS, RAMPS, CURB RAMPS EXCLUDING THE FLARED SIDES, ELEVATORS, AND PLATFORM LIFTS. [11B-403.5.3] 5. REVOLVING DOORS, REVOLVING GATES AND TURNSTILES SHALL NOT BE APART OF AN ACCESSIBLE ROUTE. [11B-402.2.1] 6. ACCESSIBLE ROUTES SHALL COMPLY WITH FLOOR AND GROUND SURFACES AND CHANGES IN LEVEL. 7. THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:20. THE CROSS SLOPE OF A WALKING SURFACE SHALL NOT BE STEEPER THAN 1:48. [11B-403.3] 8. AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES SHALL PROVIDE PASSING SPACES AT INTERVALS OF 200 FEET MAXIMUM. PASSING SPACES SHALL BE EITHER A 60 INCH MINIMUM BY 60 INCH MINIMUM SPACE, OR AN INTERSECTION OF TWO WALKING SURFACES THAT PROVIDE A T- SHAPED TURNING SPACE WHERE THE BASE AND ARMS OF THE T-SHAPED SPACE EXTEND 48 INCHES MINIMUM BEYOND THE INTERSECTION. [11B-403.5.3] 9. WORKSTATIONS SHALL BE ON AN ACCESSIBLE ROUTE. SPACES AND ELEMENTS WITHIN EMPLOYEE WORKSTATIONS SHALL ONLY BE REQUIRED TO COMPLY WITH ACCESSIBLE MEANS OF EGRESS, AUDIBLE ALARM COVERAGE, FLOOR AND GROUND SURFACES, CHANGES IN LEVEL, REACH RANGES - ELECTRICAL CONTROLS AND SWITCHES, REACH RANGES - ELECTRICAL RECEPTACLE OUTLETS. 10. MULTI-STORY BUILDINGS & FACILITIES: AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT EACH STORY AND MEZZANINE. EXCEPTIONS: MULTI-STORIED OFFICE BUILDINGS (OTHER THAN THE PROFESSIONAL OFFICE OF A HEALTH CARE PROVIDER) AND PASSENGER VEHICLE SERVICE STATIONS LESS THAN THREE STORIES HIGH OR LESS THAN 3,000 SQUARE FEET PER STORY. ANY OTHER PRIVATELY FUNDED MULTI STORIED BUILDING THAT IS NOT A SHOPPING CENTER, SHOPPING MALL OR THE PROFESSIONAL OFFICE OF A HEALTH CARE PROVIDER, OR A TERMINAL, DEPOT OR OTHER STATION USED FOR SPECIFIED PUBLIC TRANSPORTATION, OR AN AIRPORT PASSENGER TERMINAL AND THAT IS LESS THAN THREE STORIES HIGH OR LESS THAN 3,000 SQUARE FEET PER STORY IF A REASONABLE PORTION OF ALL FACILITIES AND ACCOMMODATIONS NORMALLY SOUGHT AND USED BY THE PUBLIC IN SUCH A BUILDING ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES. [11B-206.2.3] 1. ENTRANCES: IN EXISTING BUILDINGS AND FACILITIES WHERE NOT ALL ENTRANCES ARE ACESSIBLE, ENTRANCES THAT ARE ACCESSBIBLE, SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. DIRECTIONAL SIGNS THAT INDICATE THE LOCATION OF THE NEAREST ENTRANCE SHALL BE PROVIDED AT ENTRANCES THAT DO NOT COMPLY. DIRECTIONAL SIGNS, INCLUDING INTERNATIONAL SYMBOL OF ACCESSIBILITY, INDICATING THE ACCESSIBLE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE SHALL BE PROVIDED AT JUNCTIONS WHERE THE ACCESSIBLE ROUTE DIVERGES FROM THE REGULAR CIRCULATION PATH. NOTES: 1. LOCATION: CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES. [11B-406.5.1] 2. DIAGONAL OR CORNER TYPE CURB RAMPS WITH RETURNED CURBS OR OTHER WELL-DEFINED EDGES SHALL HAVE THE EDGES PARALLEL TO THE DIRECTION OF PEDESTRIAN FLOW. [11B-406.5.10] THE BOTTOM OF DIAGONAL CURB RAMPS SHALL HAVE A CLEAR SPACE 48" MINIMUM OUTSIDE ACTIVE TRAFFIC LANES OF THE ROADWAY. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS SHALL PROVIDE THE 48" MINIMUM CLEAR SPACE WITHIN THE MARKINGS.[11B-406.5.9] DIAGONAL CURB RAMPS WITH FLARED SIDES SHALL HAVE A SEGMENT OF CURB 24" LONG MINIMUM LOCATED ON EACH SIDE OF THE CURB RAMP AND WITHIN THE MARKED CROSSING.[11B-406.5.10] 3. COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO AND WITHIN 24" OF THE CURB RAMP SHALL NOT BE STEEPER THAN 1:20 THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS, AND STREETS SHALL BE AT THE SAME LEVEL. [11B-406.5.8] 4. CURB RAMPS FLARES SHALL NOT BE STEEPER THAN 1:10 [11B-406.2.2] 5. LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB RAMPS. THE LANDING CLEAR LENGTH SHALL BE 48" MINIMUM. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING FLARED SIDES LEADING TO THE LANDING. THE SLOPE OF THE LANDING IN ALL DIRECTION SHALL BE 1:48 MAXIMUM. [11B-406.5.3] 6. GRADE BREAKS AT THE TOP AND BOTTOM OF CURB RAMPS SHALL BE PERPENDICULAR TO THE DIRECTION OF THE RAMP RUN. GRADE BREAKS SHALL NOT BE PERMITTED ON THE SURFACE OF RAMP RUNS AND TURNING SPACES. SURFACE SLOPES THAT MEET AT GRADE BREAKS SHALL BE FLUSH. [11B-406.5.6] 7. CROSS SLOPES SHALL BE 1:48 MAXIMUM [11B-406.5.7] 8. PARALLEL CURB RAMPS A PARALLEL CURB RAMP MAY BE PROVIDED WITH ONE SLOPING SEGMENT OR TWO OPPOSING SEGMENTS. [11B-406.6.3] 9. DETECTABLE WARNINGS AT CURB RAMPS SHALL BE LOCATED SO THE EDGE NEAREST THE CURB IS 6" MIN. AND 8" MAX. FROM THE DEMARCATION LINE AT THE FACE OF THE CURB BETWEEN THE CURB AND THE GUTTER. [11B-705.1.2.2.1 & 11B-705.1.2.2.2] DETECTABLE WARNINGS: 1. LOCATION: DETECTABLE WARNINGS SHALL BE PROVIDED AT PLATFORM BOARDING EDGES, CURB RAMPS, ISLANDS OR CUT-THROUGH MEDIANS, BUS STOPS, BLENDED TRANSITIONS, REFLECTING POOLS, AND TRACK CROSSINGS. [11B-705.1.2] 2. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND FIRECTIONAL SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF REGULATION (CCR), TITLE 24, PART 1, CHAPTER 5, ARTICLES 2, 3, & 4. REFER TO CCR TITLE 24, PART 12, CHAPTER 11B, SECTION 12-11B.205 FOR BUILDING AND FACILITY ACCESS SPECIFICATIONS FOR PRODUCT APPROVAL FOR DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES [11B-705.3] 3. COLOR AND CONTRAST: THE MATERIAL USED TO PROVIDE VISUAL CONTRAST SHALL BE AN INTEGRAL PART OF THE DETECTABLE WARNING SURFACE. [11B-705.1.1.3] DETECTABLE WARNING SURFACES SHALL BE YELLOW AND APPROXIMATE 33538 OF SAE AMSSTD-595A. [11B-705.1.1.3.1] 4. AT CURB RAMPS: REFER TO CURB RAMP DETAIL FOR DETECTABLE WARNING REQUIREMENTS AT CURB RAMPS OR CUT-THROUGH MEDIANS. 1. LOCATION: ACCESSIBLE PARKING SPACES THAT SERVICE A PARTICULAR BUILDING OR FACILITY SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE FROM PARKING TO AN ACCESSIBLE ENTRANCE. WHERE PARKING SERVES MORE THAN ONE ACCESSIBLE ENTRANCE, ACCESSIBLE PARKING SPACES SHALL BE DISPERSED AND LOCATED ON THE SHORTEST ACCESSIBLE ROUTE TO THE ACCESSIBLE ENTRANCES.[11B-208.3.1] 2. WHERE PARKING SPACES ARE MARKED WITH LINES, WIDTH MEASUREMENTS OF PARKING SPACES AND ACCESS AISLES SHALL BE MADE FROM THE CENTERLINE OF THE MARKINGS. EXCEPTION: WHERE PARKING SPACES OR ACCESS AISLES ARE NOT ADJACENT TO ANOTHER PARKING SPACE OR ACCESS AISLE, MEASUREMENTS SHALL BE PERMITTED TO INCLUDE THE FULL WIDTH OF THE LINE DEFINING THE PARKING SPACE OR ACCESS AISLE. [11B-502.1] 3. ACCESS AISLES SERVING PARKING SPACES SHALL ADJOIN AN ACCESSIBLE ROUTE. TWO PARKING SPACES OR ONE PARKING SPACE AND ONE ELECTRIC VEHICLE CHARGING STATION SHALL BE PERMITTED TO SHARE A COMMON ACCESS AISLE. [11B-502.3] 4. ACCESS AISLES SHALL BE MARKED WITH A BLUE PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA WITHIN THE BLUE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAXIMUM OF 36 INCHES ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE, PREFERABLY BLUE OR WHITE. THE WORDS "NO PARKING" SHALL BE PAINTED ON THE SURFACE WITHIN EACH ACCESS AISLE IN WHITE LETTERS A MINIMUM OF 12 INCHES (305 MM) IN HEIGHT AND LOCATED TO BE VISIBLE FROM THE ADJACENT VEHICLE WAY. ACCESS AISLE MARKINGS MAY EXTEND BEYOND THE MINIMUM REQUIRED LENGTH. [11B-502.3.3] 5. ACCESS AISLES SHALL NOT OVERLAP THE VEHICULAR WAY. ACCESS AISLES SHALL BE PERMITTED TO BE PLACED ON EITHER SIDE OF THE PARKING SPACE EXCEPT FOR VAN PARKING SPACES WHICH SHALL HAVE ACCESS AISLES LOCATED ON THE PASSENGER SIDE OF THE PARKING SPACES. [11B-502.3.3] 6. GROUND SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT.[11B-302.1] ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE PARKING SPACES THEY SERVE. CHANGES IN LEVEL, SLOPES EXCEEDING 1:48, AND DETECTABLE WARNINGS ARE NOT PERMITTED. [11B-502.4] 7. VERTICAL CLEARANCE: PARKING SPACES, ACCESS AISLES AND VEHICULAR ROUTES SERVING THEM SHALL PROVIDE A VERTICAL CLEARANCE OF 98 INCHES MINIMUM. [11B-502.5] 8. PARKING SPACE IDENTIFICATION SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE OR BLUE BACKGROUND. SIGNS IDENTIFYING VAN PARKING SPACES SHALL CONTAIN ADDITIONAL LANGUAGE OR AN ADDITIONAL SIGN WITH THE DESIGNATION "VAN ACCESSIBLE". SIGNS SHALL BE 60 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE BOTTOM OF THE SIGN. SIGNS LOCATED WITHIN A CIRCULATION PATH SHALL BE A MINIMUM OF 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE BOTTOM OF THE SIGN.[11B-502.6] SIGNS SHALL BE VISIBLE FROM EACH PARKING SPACE, AND SHALL BE PERMANENTLY POSTED EITHER IMMEDIATELY ADJACENT TO THE PARKING SPACE OR WITHIN THE PROJECTED PARKING SPACE WIDTH AT THE HEAD END OF THE PARKING SPACE. SIGNS MAY ALSO BE PERMANENTLY POSTED ON A WALL AT THE INTERIOR END OF THE PARKING SPACE. [11B-502.6.3] 9. PARKING SPACES AND ACCESS AISLES SHALL BE DESIGNED SO THAT CARS AND VANS, WHEN PARKED CANNOT OBSTRUCT THE REQUIRED CLEAR WIDTH OF ADJACENT ACCESSIBLE ROUTES. [11B-502.7] 10. PARKING SPACES AND ACCESS AISLES SHALL BE DESIGNED SO THAT PERSONS USING THEM ARE NOT REQUIRED TO TRAVEL BEHIND PARKING SPACES OTHER THAN TO PASS BEHIND THE PARKING SPACE IN WHICH THEY ARE PARKED. [11B-502.7.1] 11. A CURB OR WHEELSTOP SHALL BE PROVIDED IF REQUIRED TO PREVENT ENCROACHMENT OF VEHICLES OVER THE REQUIRED CLEAR WIDTH OF ADJACENT ACCESSIBLE ROUTES. [11B-502.7.2] 12. FREESTANDING SIGN SHALL CLEARLY STATE IN LETTERS WITH A MINIMUM HEIGHT OF 1INCH THE FOLLOWING: "UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT: _________ OR BY TELEPHONING _________." BLANK SPACES SHALL BE FILLED IN WITH THE APPROPRIATE INFORMATION AS A PERMANENT PART OF THE SIGN. [11B-502.8.2] NOTES: 1. SCOPING: PASSENGER DROP-OFF AND LOADING ZONES SHALL BE PROVIDED IN EVERY CONTINUOUS 100 LINEAR FEET OF DROP-OFF AND LOADING ZONE SPACE, OR FRACTION THEREOF. [11B-209.2.1] 2. VEHICLE PULL-UP SPACE: PASSENGER DROP-OFF AND LOADING ZONES SHALL PROVIDE A VEHICULAR PULL-UP SPACE 96 INCHES WIDE MINIMUM AND 20 FEET LONG MINIMUM. [11B-503.2] 3. ACCESS AISLE SHALL ADJOIN AN ACCESSIBLE ROUTE, BE ADJACENT AND PARALLEL TO THE VEHICLE PULL- UP SPACE, AND SHALL NOT OVERLAP THE VEHICULAR WAY [11B-503.3] 4. ACCESS AISLES SHALL BE MARKED WITH A PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA WITHIN THE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAXIMUM OF 36 INCHES ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE SURFACE. [11B-503.3.3] 5. GROUND SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. [11B-302.1] ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACES THEY SERVE. CHANGES IN LEVEL, SLOPES EXCEEDING 1:48, AND DETECTABLE WARNINGS SHALL NOT BE PERMITTED. [11B-503.4] 6. VERTICAL CLEARANCE: VEHICLE PULL-UP SPACE, ACCESS AISLES SERVING THEM, AND A VEHICULAR ROUTE FROM AN ENTRANCE TO THE PASSENGER DROP-OFF AND LOADING ZONE, AND FROM THE PASSENGER DROP-OFF AND LOADING ZONE TO A VEHICULAR EXIT SHALL PROVIDE A VERTICAL CLEARANCE OF 114 INCHES MINIMUM. [11B-503.3.5] ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 T his D raw ing Pr odu ced by t he U.S . A cce ss Boa rd T his D raw ing Pr odu ced by t he U.S . A cce ss Boa rd T his D raw ing Pr odu ced by t he U.S . A cce ss Boa rd C C 5 max 15 min 381 127 48 m i n 18 min 36 m a x 38 - 4 3 27 m i n 48 m a x EQ EQ st a n d i n g s p o u t o u t l e t 17 max 432 343 13½ min 13½ min 343 100-120 4-4.8 perimeter projecting object above grab bar projecting object below grab bar 34 " m a x @ 86 4 30 " m i n 48" min 17"-19" at lavatory 18 " m i n 18 " m i n 19"-25" at sink, dining table and work surface 45 7 4 5 7 1219 432-483 483-635 76 2 29 " m i n 73 7 27 " m i n 68 6 min 203 8" min 279 11" ri m o r c o u n t e r 48 m i n 12 1 9 48 m i n 12 1 9 48 m i n 12 1 9 32 min 813 32 min 813 32 clear min 813 90° 60 m i n 15 2 4 12 1 9 48 m i n 12 1 9 48 m i n 12 min 305 36 min 914 60 m i n 15 2 4 48 m i n 12 1 9 559 22 min 44 m i n 11 1 8 22 min 559 24 min 60 m i n 61015 2 4 24 min 44 m i n 11 1 8 610 610 24 min 12 1 9 48 m i n 12 1 9 48 m i n 42 m i n 10 6 7 22 min 559 24 min 61010 6 7 42 m i n 60 m i n 15 2 4 18 min at interior 457 X > 8 203 12 1 9 48 m i n 12 1 9 48 m i n 12 min 305 X > 8 203 10 6 7 42 m i n X > 8 203 24 min at exterior 610 18 min at interior 457 24 min at exterior 610 36 min 914 24 m a x 61 0 32 min 813 38 m a x 2 max 51 96 5 36 min 914 36 min 914 *24 min 610 *24 min 610 17-18 432-457 432-483 17-19 60 min 56 m i n 14 2 2 1524 66 m i n 16 7 6 26 min 660 60 min 1524 12 max 42 min 54 min 1372 305 1067 12 min 30524 min 610 36 min 914 19 m i n 48 3 7-9 178-229 1422 15 2 4 60 m i n 60 m i n 15 2 4 4 max 102 10 2 4 m a x 152 9 min 229 6 min partition 6 min 152 6 min 12 min 152 305 partition 35-37 889-940 15 2 4 60 m i n 11 1 8 44 m i n 17"-19" 432-483 33 - 3 6 83 8 - 9 1 4 to p o f b a r 1 1/2 min 38 33 - 3 6 83 8 - 9 1 4 to p o f b a r 48 m i n 12 1 9 to o u t l e t 56 min @ wall mounted 48 min maneuvering space 1219 water closet 1499 59 min @ floor mounted water closet 1422 56 min @ wall mounted water closet 1499 59 min @ floor mounted water closet 48 min maneuvering space 1219 door permitted to swing over hatched portion of maneuvering space 36 min 914 door permitted to swing over hatched portion of maneuvering space 60 m i n 15 2 4 1422 56 min @ wall mounted water closet 1499 59 min @ floor mounted water closet 60 min @ side door maneuvering space 1524 60 m i n 15 2 4 1422 56 min @ wall mounted water closet 1499 59 min @ floor mounted water closet 60 min @ maneuvering space 1524 door permitted to swing over hatched portion of maneuvering space 36 min 914 12 1 9 48 m i n 34 min 864 34 min 864 81 3 32 m i n 81 3 32 m i n 24 min 610 19 m i n t. o . o p e n i n g 54 min 1372 18 min 457 18 min 45745° centered on tactile characters 6 m i n 15 2 not in pictogram field 15 . 9 - 5 1 3/8" - 1/2" 3/8" min 9.5 - 12.7 9.5 5/ 8 - 2 blank cell space between words base diameter distance between dots in the same cell distance between dots in the same cell in adjacent cells single braille cell raised dot no raised dot from one cell directly below clear floor area 58 - 6 0 14 7 3 - 1 5 2 4 12 1 2 12 30 5 30 5 305 CL distance between corresponding dots distance between corresponding dots 1/8 min - 1/4 max 3.2 - 6.4 radius @ vertices eased/rounded chamfered edges 1/8 max 3.2 38 12 m i n 30 5 1½ min 38 1½ CL folding door hinged door sliding door front approach, pull side front approach, push side front approach, push side,door provided with both closer and latch hinge approach, pull side hinge approach, push side hinge approach, push side, door provided with both closer and latch latch approach, pull side latch approach, push side latch approach, push side, door provided with closer front approach side approachsliding door pocket or hinge approach sliding door stop or latch approach alcove pull side alcove push side alcove push side, door provided with both closer and latch doorways without doors doors in a series x > 8, measured perpendicular to the face of the door or gate CL co u n t e r CL co u n t e r alternate doorlocation CL CL CL CL transfer side This Dr awing Pr o duced by t he U. S. Access Boar d 34" A.F.F. MAXIMUM SAME DEPTH AS COUNTER COMPLYING KNEE CLEARANCE DRINKING FOUNTAIN SPOUT LOCATION DRINKING FOUNTAIN HEIGHT REQUIREMENTS HEIGHT OF RAISED CHARACTERS POSITION OF BRAILLE HEIGHT OF TACTILE CHARACTERS ABOVE FINISHED FLOOR OR GROUND BRAILLE MEASUREMENTS BRAILLE DIMENSIONS INTERNATIONAL SYMBOL OF ACCESSIBILITY INTERNATIONAL SYMBOL OF TTY VOLUME CONTROL TELEPHONE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS PICTOGRAM FIELD VISUAL CHARACTER HEIGHT * WOMEN'S TOILET MEN'S TOILET ALL-GENDER RESTROOM TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS LOCATION OF TACTILE SIGNS AT DOORS EDGES AND VERTICES ON GEOMETRIC SYMBOLS WALL HUNG TYPE STALL TYPE SPACING OF GRAB BARSSIZE OF GRAB BARS CHECK-OUT AISLE COUNTERS PARALLEL APPROACH-SALES AND SERVICE COUNTERS FORWARD APPROACH SALES AND SERVICE COUNTERS WHEELCHAIR ACCESSIBLE WATER CLOSETS AMBULATORY ACCESSIBLE WATER CLOSETS END OPENING DOOR OUT-SWINGING DOOR END OPENING DOOR IN-SWINGING DOOR ELEVATION ADULT ELEVATION CHILDREN TOE CLEARANCE AT ACCESS. TOILET COMP. PLAN - TOE CLEARANCESIZE OF CLEARANCE AT WATER CLOSETS OVERLAP OF WATER CLOSET IN RESIDENTIAL DWELLING UNITS SIDE WALL GRAB BAR AT WATER CLOSETS REAR WALL GRAB BAR AT WATER CLOSETS DISPENSER OUTLET LOCATION WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS AMBULATORY ACCESSIBLE TOILET COMPARTMENT SIDE OPENING OUT-SWINGING DOOR SIDE OPENING IN-SWINGING DOOR DRINKING FOUNTAINS COMMUNICATION ELEMENTS AND FEATURES URINALS GRAB BARS LAVATORIES AND SINKSDOORS, DOORWAYS, AND GATES CHECKOUT STANDS TOILET COMPARTMENTS SALES AND SERVICE COUNTERS REV 01.18.24 SCOPING (PER 11B-211) NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED, ONE ACCESSIBLE AND ONE FOR STANDING PERSONS. WHERE A SINGLE DRINKING FOUNTAIN COMPLIES WITH BOTH, IT SHALL BE PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING FOUNTAINS. BOTTLE FILLING STATIONS SHALL COMPLY WITH OPERABLE PARTS REV 01.18.24 0.059 (1.5MM) TO 0.063 (1.6MM) MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES 0.100 (2.5MM) DOT BASE DIAMETER DISTANCE BETWEEN TWO DOTS IN THE SAME CELL * 0.300(7.6MM)DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS * 0.025 (0.6MM) TO 0.037 (0.9MM)DOT HEIGHT 0.395 (10MM) TO 0.400 (10.2MM)DISTANCE BETWEEN CORRESPONDING DOTS FROM ONE CELL DIRECTLY BELOW * LESS THAN 72 INCHES HEIGHT TO FINISH FLOOR OR GROUND FROM BASELINE OF CHARACTER HORIZONTAL VIEWING DISTANCE 40 INCHES TO LESS THAN OR EQUAL TO 70 INCHES GREATER THAN 70 INCHES TO LESS THAN OR EQUAL TO 120 INCHES MINIMUM CHARACTER HEIGHT 5/8 INCH 5/8 INCH, PLUS 1/8 INCH PER FOOT OF VIEWING DISTANCE ABOVE 72 INCHES LESS THAN 180 INCHES 2 INCHES 2 INCHES, PLUS 1/8 INCH PER FOOT OF VIEWING DISTANCE ABOVE 180 INCHES GREATER THAN 120 INCHES 21 FEET AND GREATER LESS THAN 21 FEET 3 INCHES 3 INCHES, PLUS 1/8 INCH PER FOOT OF VIEWING DISTANCE ABOVE 21 FEET * FLOOR-LEVEL EXIT SIGNS COMPLYING WITH CHAPTER 10 SHALL NOT BE REQUIRED TO COMPLY WITH MOUNTING HEIGHTS SHOWN GEOMETRIC SYMBOL, 1/4" THICK SIGN, LIGHT ON DARK OR DARK ON LIGHT BACKGROUND STRIKE SIDE OF DOOR MOUNTED WITHIN 1 INCH OF VERTICAL CENTER- LINE OF DOOR * MEASURED CENTER TO CENTER 72 INCHES AND GREATER 180 INCHES AND GREATER 3 - CHECK-OUT AISLES 11B-227 & 11B-904 REV 01.18.24 REV 01.18.24 2 - GRAB BARS 11B-609 REV 01.18.24 30x48 REQUIRED CLEAR SPACE 4 - LAVATORIES AND SINKS 11B-606 8 - DRINKING FOUNTAINS + BOTTLE FILLING STATIONS 11B-211 / 11B-602 7 - URINALS 11B-213 & 11B-605 REV 01.18.24 20 - DOORS, DOORWAYS, AND GATES 11B-404 NUMBER OF CHECK OUT AISLES OF EACH FUNCTION MINIMUM NUMBER TO BE ACCESSIBLE 1 2 3 1 TO 4 5 TO 8 9 TO 15 16 AND OVER 3 PLUS 20% OF ADDITIONAL AISLES REV 01.18.24 * IN ALTERATIONS WHERE FORWARD OR PARALLEL APPROACH WOULD RESULT IN A REDUCTION OF THE NUMBER OF EXISTING COUNTERS AT WORK STATIONS THE COUNTER CAN BE REDUCED TO 24 INCHES REV 01.18.24 AT LEAST ONE SIDE PARTITION SHALL PROVIDE TOE CLEARANCE OF 9" (229mm) MINIMUM ABOVE THE FINISH FLOOR AND 6" (152mm) DEEP MINIMUM BEYOND THE COMPARTMENT-SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS. PARTITION COMPONENTS AT TOE CLEARANCES SHALL BE SMOOTH WITHOUT SHARP EDGES OR ABRASIVE SURFACES.EXCEPTION:TOE CLEARANCE AT THE SIDE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 66" (1676mm) WIDE. [11B-604.8.1.4] CLEARANCE CLEARANCE CLEARANCE CLEARANCE CLEARANCE 18 - TOILET COMPARTMENTS 11B-213/603-606 17 - COMMUNICATION ELEMENTS AND FEATURES 11B-702 & 703 MEN LIBRARY AREA OF REFUGE REFUGE AREA OF AREA OF REFUGE 12 1 9 15 2 4 48 m i n t o l o w e s t br a i l l e c e l l 60 m a x t o b a s e l i n e o f hi g h e s t l i n e o f r a i s e d ch a r a c t e r s ALL-GENDER RESTROOM 2 max 512 ma x 51 1¼ -2 32-51 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 ACCESSIBILITY DETAILS (CA) BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 G-103 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 NOTES: 1. FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72 AND CHAPTER 9, SECTIONS 907.5.2.1 AND 907.5.2.3. [11B-702.1] 2. WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ONE SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILE CHARACTERS, SHALL BE PROVIDED. [11B-703.1] 3. RAISED CHARACTERS SHALL BE 1/32 INCH MINIMUM ABOVE THEIR BACKGROUND AND SHALL BE UPPERCASE. [11B-703.2.1 & 11B-703.2.2] 4. CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIP, HIGHLY DECORATIVE OR OF OTHER UNUSUAL FORMS. [11B-703.2.3] 5. CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I". [11B-703.2.4] 6. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8 INCH MINIMUM AND 2 INCHES MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". [11B-703.2.5] 7. STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 15 PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER. [11B-703.2.6] 8. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT RAISED CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. WHERE CHARACTERS HAVE RECTANGULAR CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM. WHERE CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/16 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE BASE OF THE CROSS SECTIONS, AND 1/8 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE SEPARATED FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8" MINIMUM. [11B-703.2.7] 9. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHARACTERS WITHIN A MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE RAISED CHARACTER HEIGHT. TEXT SHALL BE IN A HORIZONTAL FORMAT. [11B-703.2.8 & 11B-703.2.9] 10. BRAILLE SHALL BE CONTRACTED (GRADE 2). [11B-703.3] 11. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11B-703.3.1. THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OF THE ALPHABET, INITIALS, AND ACRONYMS. [11B-703.3.3.1] 12. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR CENTERED. IF TEXT IS MULTI LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. BRAILLE SHALL BE SEPARATED 3/8 INCH MINIMUM AND 1/2 INCH MAXIMUM FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH MINIMUM FROM RAISED BORDERS AND DECORATIVE ELEMENTS. EXCEPTION: BRAILLE PROVIDED ON ELEVATOR CAR CONTROLS SHALL BE SEPARATED 3/16 INCH MINIMUM AND SHALL BE LOCATED DIRECTLY BELOW THE CORRESPONDING RAISED CHARACTERS OR SYMBOLS. [11B-703.3.2] 13. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MIN. ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES MAX. ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. EXCEPTION: TACTILE CHARACTERS FOR ELEVATOR CAR CONTROLS SHALL NOT BE REQUIRED TO COMPLY. [11B-703.4.1] 14. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGN SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. WHERE PROVIDED, SIGNS IDENTIFYING PERMANENT ROOMS AND SPACES SHALL BE LOCATED AT THE ENTRANCE TO, AND OUTSIDE OF THE ROOM OR SPACE. WHERE PROVIDED, SIGNS IDENTIFYING EXITS SHALL BE LOCATED AT THE EXIT DOOR WHEN APPROACHED IN THE DIRECTION OF EGRESS TRAVEL. EXCEPTION: IN ALTERATIONS WHERE SIGN INSTALLATION LOCATIONS IDENTIFIED IN SECTION 11B-703.4.2 ARE OBSTRUCTED OR OTHERWISE UNAVAILABLE FOR SIGN INSTALLATION, SIGNS WITH TACTILE CHARACTERS SHALL BE PERMITTED ON THE PUSH SIDE OF DOORS WITH CLOSERS AND WITHOUT HOLD-OPEN DEVICES. [11B-703.4.2] 15. CHARACTERS AND THEIR BACKGROUNDS SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. [11B-703.5.1] 16. VISUAL CHARACTERS SHALL BE UPPERCASE OR LOWERCASE OR A COMBINATION OF BOTH. [11B-703.5.2] 17. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE COLOR BLUE SHALL APPROXIMATE FS 15090 IN FEDERAL STANDARD 595C. EXCEPTIONS: THE APPROPRIATE ENFORCEMENT AGENCY MAY APPROVE OTHER COLORS PROVIDED THE SYMBOL CONTRAST IS LIGHT ON DARK OR DARK ON LIGHT. [11B-703.7.2.1] TOILET AND BATHING ROOMS 1. CLEARANCES: 60" (1524mm) DIA. MIN. TURNING SPACE SHALL BE PROVIDED WITHIN THE ROOM. [11B-603.2.1] REQUIRED CLEAR FLOOR SPACES, CLEARANCE AT FIXTURES, AND TURNING SPACE SHALL BE PERMITTED TO OVERLAP. [11B-603.2.2] DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS TO ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL BE PERMITTED TO ENCROACH INTO THE TURNING SPACE WITHOUT LIMITATION. OTHER THAN THE DOOR TO THE ACCESSIBLE WATER CLOSET COMPARTMENT, A DOOR IN ANY POSITION, SHALL BE PERMITTED TO ENCROACH INTO THE TURNING SPACE BY 12 INCHES MAX. EXCEPTION:WHERE THE TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL USE AND A COMPLYING CLEAR FLOOR SPACE IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE. [11B-603.2.3] 2. MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 40" (1016mm) MAX. ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35" (889mm) MAX. ABOVE THE FINISH FLOOR OR GROUND. [11B-603.3] 3. COAT HOOKS, SHELVES AND MEDICINE CABINETS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN THE CODE. SHELVES SHALL BE LOCATED 40" (1016mm) MIN. AND 48" (1219mm) MAX. ABOVE THE FINISHED FLOOR. MEDICINE CABINETS SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44" (1118mm) MAX. A.F.F. [11B-603.4] 4. ACCESSORIES: WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON A ACCESSIBLE ROUTE, ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40" (1016mm) MAX. ABOVE THE FINISH FLOOR. EXCEPTION: BABY CHANGING TABLES ARE NOT REQUIRED TO COMPLY WITH THESE REQUIREMENTS. [11B-603.5] WATER CLOSETS AND TOILET COMPARTMENTS 1. OVERLAP: THE REQUIRED CLEARANCES AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE. [11B-604.3.2] 1. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH REACH RANGES EXCEPT THEY SHALL BE LOCATED 44 INCHES MAXIMUM ABOVE THE FLOOR, AND NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST, THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET EXCEPT IN AMBULATORY ACCESSIBLE COMPARTMENTS. [11B-604.6] DISPENSERS 1. TOILET DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW. [11B-604.7.1] REQUIRED # OF ACCESSIBLE TOILET COMPARTMENTS AND PLUMBING FIXTURES: 1. WHERE TOILET COMPARTMENTS ARE PROVIDED AT LEAST 5 PERCENT OF THE TOILET COMPARTMENTS, OR FIVE PERCENT OF THE COMBINATION OF TOILET COMPARTMENTS AND URINALS, BUT NO FEWER THAN 1 TOILET COMPARTMENT SHALL BE ACCESSIBLE. [11B-213.3.1] WHERE WATER CLOSETS ARE PROVIDED, AT LEAST 5 PERCENT BUT NO FEWER THAN ONE SHALL BE ACCESSIBLE. [11B-213.3.2] WHERE ONE OR MORE URINALS ARE PROVIDED, AT LEAST 10 PERCENT BUT NO FEWER THAN ONE SHALL BE ACCESSIBLE. [11B-213.3.3] WHERE LAVATORIES ARE PROVIDED, AT LEAST 10 PERCENT BUT NO FEWER THAN ONE SHALL BE ACCESSIBLE. [11B-213.3.4] IN ADDITION, TO THE COMPARTMENTS REQUIRED TO COMPLY, WHERE SIX OR MORE TOILET COMPARTMENTS ARE PROVIDED, OR WHERE THE COMBINATION OF URINALS AND WATER CLOSETS TOTAL 6 OR MORE FIXTURES, AMBULATORY COMPARTMENTS SHALL BE PROVIDED IN THE SAME QUANTITY AS WHEELCHAIR ACCESSIBLE COMPARTMENTS. [11B-213.3.1] BABY CHANGING TABLES: 1. BABY CHANGING TABLES SHALL COMPLY WITH WORK SURFACES, AND OPERABLE PARTS SHALL COMPLY WITH CLEAR FLOOR SPACE, HEIGHT AND REACH RANGES. THEY SHALL NOT OBSTRUCT THE REQUIRED WIDTH OF AN ACCESSIBLE ROUTE BY MORE THAN 4 INCHES, AND SHALL NOT BE LOCATED IN ACCESSIBLE TOILET COMPARTMENTS WITHIN A MULTIPLE ACCOMMODATION TOILET FACILITY. [11B-226.4] NOTES: 1. GRAB BARS IN ACCESSIBLE TOILET OR BATHING FACILITIES SHALL COMPLY. [11B-609.1] 2. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE FLOOR MEASURED TO THE TOP OF THE GRIPING SURFACE. [11B-609.4] 3. GRAB BARS, AND ANY WALL OR OTHER SURFACES ADJACENT TO GRAB BARS SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS AND SHALL HAVE ROUNDED EDGES. [11B-609.5] 4. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. [11B-609.6] 5. GRAB BARS SHALL BE INSTALLED IN ANY MANNER THAT PROVIDES A GRIPPING SURFACE AT THE LOCATIONS SPECIFIED IN THIS STANDARD AND DOES NOT OBSTRUCT THE CLEAR FLOOR SPACE. [11B-609.7] 6. STRUCTURAL STRENGTH. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. [11B-609.8] NOTES: 1. DOUBLE LEAF DOORS AND GATES: AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH CLEAR WIDTHS AND CLEARANCES. [11B-404.2.2] 2. PROJECTIONS: THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES. EXCEPTION; IN ALTERATIONS, A PROJECTION OF 5/8" MAXIMUM INTO THE REQUIRED CLEAR WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. [11B-404.2.3] 3. PROVIDE REQUIRED MANEUVERING SPACE AT DOORS. MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. [11B-404.2.4] 4. THRESHOLDS IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH HIGH MAXIMUM. RAISED THRESHOLDS SHALL COMPLY WITH CHANGES IN LEVEL. [11B-404.2.5] 5. DOOR AND GATE HARDWARE: HANDLES, PULLS, LATCHED, LOCKS AND OTHER OPERABLE PARTS ON DOOR AND GATES SHALL BE 34 INCHES MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FINISHED FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. EXCEPTION: EXISTING LOCKS SHALL BE PERMITTED IN ANY LOCATION AT EXISTING GLAZED DOORS WITHOUT STILES, EXITING OVERHEAD ROLLING DOORS OR GRILLES, AND SIMILAR EXISTING DOORS OR GRILLES THAT ARE DESIGNED WITH LOCKS THAT ARE ACTIVATED ONLY AT THE TOP OR BOTTOM RAIL. [11B-404.2.7] 6. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES,THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. [11B-404.2.8.1] 7. SPRING HINGES DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS. [11B-404.2.8.2] 8. DOOR AND GATE OPENING FORCE. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL BE 5 POUNDS FOR INTERIOR OR EXTERIOR DOORS, GATES, SLIDING OR FOLDING DOORS. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. [11B-404.2.9] 9. DOOR AND GATE SURFACES. SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISHED FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. EXCEPTIONS; SLIDING DOORS ARE NOT REQUIRED TO COMPLY. TEMPERED GLASS DOORS WITHOUT STILES AND HAVING A BOTTOM RAIL OR SHOE WITH THE TOP LEADING EDGE TAPERED AT 60 DEGREES MINIMUM FROM THE HORIZONTAL SHALL NOT BE REQUIRED TO MEET THE 10 INCH BOTTOM SMOOTH SURFACE HEIGHT REQUIREMENT. DOORS AND GATES THAT DO NOT EXTEND TO WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY. [11B-404.2.10] 10. VISION LIGHTS: DOORS , GATES AND SIDE LIGHTS ADJACENT TO DOORS OR GATES, CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE GLAZED PANEL LOCATED 43 INCHES MAXIMUM ABOVE THE FINISH FLOOR. EXCEPTION: GLAZING PANELS WITH THE LOWEST PART MORE THAN 66 INCHES FROM THE FINISH FLOOR OR GROUND SHALL NOT BE REQUIRED TO COMPLY. [11B-404.2.11] 11. AUTOMATIC AND POWER ASSISTED DOORS AND GATES. AUTOMATIC DOORS AND AUTOMATIC GATES SHALL COMPLY WITH ANSI/BHMA A156.10. LOW ENERGY AND POWER ASSISTED DOORS SHALL COMPLY WITH ANSI/BHMA A156.19. AUTOMATIC DOORS SHALL PROVIDE A CLEAR OPENING OF 32 INCHES MINIMUM IN POWER-ON AND POWER-OFF MODE. THE MINIMUM CLEAR WIDTH OF AUTOMATIC DOOR SYSTEMS IN A DOORWAY SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING OF 32 INCHES WITH ONE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. MANEUVERING CLEARANCES AND THRESHOLDS AT POWER ASSISTED AND AUTOMATIC DOORS SHALL COMPLY. EXCEPTION: WHERE AUTOMATIC DOORS AND GATES REMAIN OPEN IN THE POWER-OFF CONDITION, MANEUVERING CLEARANCES ARE NOT REQUIRED. MANUAL CONTROLS SHALL COMPLY WITH REACH RANGES AND BE LOCATED BEYOND THE ARC OF THE DOOR SWING. WHERE DOORS AND GATES WITHOUT STANDBY POWER ARE A PART OF A MEANS OF EGRESS, THE CLEAR BREAK OUT OPENING AT SWINGING OR SLIDING DOORS AND GATES SHALL BE 32 INCHES MINIMUM WHEN OPERATED IN EMERGENCY MODE.[11B-404.3] NOTES 1. KITCHEN WORK SURFACE SHALL BE 34 INCHES MAX ABOVE THE FINISH FLOOR. [11B-804.3.2] 2. AT LEAST 50% OF SHELF SPACE IN STORAGE FACILITIES SHALL BE ACCESSIBLE. [11B-804.5] 3. SINKS SHALL BE ACCESSIBLE. EXCEPTION: A PARALLEL APPROACH SHALL BE PERMITTED TO A KITCHEN SINK IN A SPACE WHERE A COOK TOP OR RANGE IS NOT PROVIDED.[11B-606.2] 4. A CLEAR FLOOR SPACE SHALL BE PROVIDED AT EACH APPLIANCE. [11B-804.6.1] 5. DISHWASHER: CLEAR FLOOR OR GROUND SPACE SHALL BE POSITIONED ADJACENT TO THE DISHWASHER DOOR. THE DISHWASHER DOOR, IN THE OPEN POSITION, SHALL NOT OBSTRUCT THE CLEAR FLOOR OR GROUND SPACE FOR THE DISHWASHER OR THE SINK. [11B-804.6.3] 6. COMBINATION REFRIGERATOR/FREEZER SHALL HAVE AT LEAST 50% OF THE FREEZER SPACE 54 INCHES MAX ABOVE THE FINISHED FLOOR. [11B-804.6.6] NOTES: 1. REQUIRED COMPLIANT CHECKOUT AISLES SHALL BE LOCATED ADJACENT TO AN ACCESSIBLE ROUTE. [11B-904.2] 2. WHERE PROVIDED CHECK WRITING SURFACES SHALL BE 28" MIN. & 34" MAX. ABOVE FINISH FLOOR. [11B-904.3.3] 3. WHEN NOT ALL CHECK-OUT AISLES ARE ACCESSIBLE, ACCESSIBLE CHECK-OUT AISLES SHALL BE IDENTIFIED BY A SIGN CLEARLY VISIBLE TO A PERSON IN A WHEELCHAIR DISPLAYING THE 4 INCH BY 4 INCH (MIN) ISA SIGN. [11B-227.2] 4. WHERE CHECK-OUT AISLES SERVE DIFFERENT FUNCTIONS. CHECK-OUT AISLES COMPLYING SHALL BE PROVIDED IN ACCORDANCE WITH THE TABLE ABOVE FOR EACH FUNCTION, WHERE CHECK-OUT AISLES ARE DISPERSED THROUGHOUT THE BUILDING OR FACILITY, COMPLYING CHECK-OUT AISLES SHALL BE DISPERSED. EXCEPTION; WHERE THE SELLING SPACE IS UNDER 5000 SQUARE FEET NO MORE THAN ONE CHECK-OUT AISLE COMPLYING SHALL BE REQUIRED. [11B-227.2] 5. WHERE CHECKOUT AISLES ARE ALTERED, AT LEAST ONE OF EACH CHECK-OUT AISLE SERVING EACH FUNCTION SHALL COMPLY UNTIL THE NUMBER OF CHECK-OUT AISLES COMPLIES WITH THE TABLE ABOVE. [11B-227.2.1] NOTES: 1. A CLEAR FLOOR SPACE POSITIONED FOR A FORWARD APPROACH & CENTERED ON THE UNIT SHALL BE PROVIDED. KNEE AND TOE CLEARANCE SHALL BE PROVIDED. [11B-602.2] 2. OPERABLE PARTS SHALL COMPLY WITH OPERABLE PARTS REQUIREMENTS. THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE MOUNTED AND LOCATED WITHIN 6 INCHES OF THE FRONT EDGE OF THE FOUNTAIN OR AN AUTOMATIC ELECTRONICALLY CONTROLLED DEVICE. [11B-602.3] 3. SPOUT OUTLETS OF WHEELCHAIR ACCESSIBLE DRINKING FOUNTAINS SHALL BE 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR. [11B-602.4] SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM ABOVE THE FINISH FLOOR. [11B-602.7] 4. THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES HIGH MINIMUM AND SHALL BE LOCATED 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATED LESS THAN 3 INCHES OF THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 30 DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED BETWEEN 3 INCHES AND 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAXIMUM. [11B-602.6] 5. DEPTH: WALL AND POST-MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18 INCHES MINIMUM AND 19 INCHES MAXIMUM IN DEPTH. [11B-602.8] 6. PEDESTRIAN PROTECTION: ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN WHICH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32 INCHES WIDE MINIMUM AND 18 INCHES DEEP MINIMUM, AND SHALL COMPLY WITH MANEUVERING CLEARANCES FOR ALCOVES. WHEN USED, WING WALLS OR BARRIERS SHALL PROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES VERTICALLY FROM THE FLOOR OR GROUND SURFACE. [11B-602.9] NOTES: 1. A CLEAR FLOOR SPACE POSITIONED FOR FORWARD APPROACH SHALL BE PROVIDED. EXCEPTION: A PARALLEL APPROACH SHALL BE PERMITTED TO A KITCHEN SINK IN A SPACE WHERE A COOK TOP OR CONVENTIONAL RANGE IS NOT PROVIDED AND TO WET BARS. [11B-606.2] 2. KNEE AND TOE CLEARANCE SHALL BE PROVIDED, HOWEVER THE DIP OF THE OVERFLOW SHALL NOT BE CONSIDERED IN DETERMINING KNEE AND TOE CLEARANCES. [11B-606.2, EXCEPTION 6] 3. CONTROLS FOR FAUCETS SHALL COMPLY WITH OPERABLE PARTS. HAND-OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM. [11B-606.4] 4. WHERE ENHANCED REACH RANGE IS REQUIRED AT LAVATORIES, FAUCETS AND SOAP DISPENSER CONTROLS SHALL HAVE A REACH DEPTH OF 11 INCHES MAXIMUM OR, IF AUTOMATIC, SHALL BE ACTIVATED WITHIN A REACH DEPTH OF 11 INCHES MAXIMUM. WATER AND SOAP FLOW SHALL BE PROVIDED WITH A REACH DEPTH OF 11 INCHES MAXIMUM. 5. WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. [11B-606.5] ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 RA M P INTERIOR: 18" MINIMUM EXTERIOR: 24" MINIMUM DISTANCE BEYOND THE STRIKE EDGE OF A GATE OR DOOR ON THE SIDE TOWARD WHICH IT SWINGS NOTES: 1. IF (X) IS GREATER THAN 3" THEN (Y) MUST BE: 60" MINIMUM AT TOP OF LANDING 72" MINIMUM AT BOTTOM LANDING 2. WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING MANEUVERING CLEARANCES SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. [11B-405.7.5] 3. DOORS, WHEN FULLY OPEN , SHALL NOT REDUCE THE REQUIRED RAMP LANDING WIDTH BY MORE THAN 3 INCHES. DOORS, IN ANY POSITION, SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP LANDING TO LESS THAN 42 INCHES. [11B-405.7.5] 305 45 7 64 2½ min 2½ min 64 72 m i n 18 2 9 2 m i n 51 80 min 42 min 2032 1067 12 9 5 13 7 2 51 m i n 54 m i n 68 min 36 min 1727 914 13 7 2 12 9 5 54 m i n 51 m i n 54 min 36 min 1372 914 20 3 0 80 m i n 60 min 36 min 1524 914 15 2 4 60 m i n 42 m i n 813 32 min 13 7 2 54 m i n 48 min 1219 18 sq ft min 1.67 m² 10 6 7 40 m i n * 10 1 6 60 min 1524 60 min 1524 24 61 0 24 61 0 36 min 610 2 m a x 18 m i n 51 45 7 64 2½ max 20-24 508-610 17 - 1 9 43 2 - 4 8 3 48 min 1219 20 - 2 4 50 8 - 6 1 0 bench30x48 clear floor space 34 - 3 8 86 4 - 9 6 5 86 4 - 9 6 5 34 - 3 8 34 - 3 8 86 4 - 9 6 5 38 1½ min 38 1½ m i n 12 min 305 12 min 305 12 min 305 X 102-159 4-6¼ perimeter 12 min 305 12 plus tread 305 depth min 114 4½ max* *3½ max at ramps 12.7 30° max 32 11/4 max radius ½ max 32 11/4 max 279 11 min 102-178 4-7 72 min 1829 1524 60 min 60 min 1524 72 m i n 18 2 9 at least as wide as ramp run X < 4 102 60 m i n 15 2 4 60 min 1524 3-1/2" max 89 1219 48 min 1067 1067 15 2 4 10 6 7 platform li f t m e c h a n i s m CL CL CL Pass Through Kitchens U-Shaped Kitchens ref d/w ref d/w ref d/w plan CL co u n t e r stairs ramps walking surfaces Note: X = tread depth curved nosing beveled nosingangled riserradius of tread edge (typical for all profiles) ramp run landinglanding landing ramp run ra m p r u n landing bottom top This Dr a wing Pr o duce d by th e U. S. A cces s Bo ar d This Dr awing Pr o duced by t he U. S. Access Boar d 1'-0" MIN 1' - 6 " M I N 60 M I N . 42 MIN. (Y ) 42 M I N . DO O R WI D T H (X) (Y) 42 MIN. (X ) CENTERED DOOR SIDE (OFF-CENTERED) DOOR ANY DOOR LOCATION EXCEPTION EXISTING ELEVATOR CAR CONFIGURATION PLATFORM LIFT DOORS AND GATESANY DOOR LOCATION FLOOR DESIGNATIONHEIGHT OF SIGNALS EXIT FORWARD APPROACH BENCH BACK SUPPORT AND SEAT HEIGHT CLEAR FLOOR SPACE AND DIMENSIONS TOP AND BOTTOM HANDRAIL EXTENSIONS AT RAMPS TOP HANDRAIL EXTENSIONS AT STAIRS BOTTOM HANDRAIL EXTENSIONS AT STAIRS HANDRAIL NON-CIRCULAR CROSS SECTION HANDRAIL HEIGHT HANDRAIL CLEARANCE CHANGE IN DIRECTIONSTRAIGHT CURB OR BARRIER EDGE PROTECTION HANDRAIL ENCROACHMENT TACTILE FLOOR DESIGNATION SIGNS IN STAIRS ELEVATORS KITCHENS AND KITCHENETTES TACTILE EXIT SIGN DINING AND WORK SURFACES SEATS AND BENCHES HANDRAILS STAIRWAYS RAMPS 60" MAX TO HIGHEST LINE OF TACTILE TEXT REV 01.18.24 NORTH STAIR NO ROOF ACCESS 1 TO 2 1" SIZE W/ 1/4" STROKE TO INDICATE THE STAIR'S UPPER TERMINUS (SUCH AS ROOF ACCESS OR NO ROOF ACCESS), PLACED UNDER THE STAIRWAY IDENTIFICATION 5" MIN. TALL W/ 3/4" STROKE FOR NUMBER DESIGNATING THE FLOOR LEVEL AND IN THE CENTER OF THE SIGN. CORRESPONDING TYPE II BRAILLE UNDER EACH INFORMATION ITEM 11/2" MIN. SIZE W/ 1/4" STROKE FOR LETTERS DESIGNATING THE IDENTIFICATION OF THE STAIR ENCLOSURE PLACED AT TOP OF SIGN 1" SIZE W/ 1/4" STROKE REV 01.18.24 REV 01.18.24 * SPACES THAT DO NOT PROVIDE A COOKTOP OR CONVENTIONAL RANGE CAN BE REDUCED TO 36 INCHES 11 - KITCHENS AND KITCHENETTES 11B-212, 606.2 & 11B-804 20 - TACTILE FLOOR DESIGNATION SIGNS IN STAIRS 1013, 1023.9 & 11B-504.8 3 - TACTILE EXIT SIGNS 1013.4 & 11B-703 REV 01.18.24 GRADE 2 BRAILLE (CENTER OR FLUSH LEFT) FINISHED FLOOR REV 01.18.24 2 - DINING AND WORK SURFACES 11B-226 & 11B-902 REV 01.18.24 5 - HANDRAILS 11B-505 & 1014.8 7 - BENCHES 11B-903 REV 01.18.24 REV 01.18.24 6 - STAIRWAYS 11B-504 19 - ELEVATORS 11B-407, 11B-410 & 1009.8 12 - RAMPS 11B-405 RAMP RAMP REV 01.18.24 MOUNTING LOCATION TYP. STAIR SIGNAGE 11 12 1 9 15 2 4 48 m i n t o l o w e s t br a i l l e c e l l 60 m a x t o b a s e l i n e of t h e h i g h e s t l i n e of r a i s e d c h a r a c t e r s 1¼ -2 32-51 2¼ max 572¼ m a x 57 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 ACCESSIBILITY DETAILS (CA) BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 G-104 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 NOTES: 1. ELEVATORS SHALL COMPLY WITH 11B-407 AND WITH ASME A17.1. THEY SHALL BE PASSENGER ELEVATORS AS CLASSIFIED BY ASME A17.1. ELEVATOR OPERATION SHALL BE AUTOMATIC. [11B-407.1] 2. COMBINED PASSENGER AND FREIGHT ELEVATORS. WHEN THE ONLY ELEVATORS PROVIDED FOR USE BY THE PUBLIC AND EMPLOYEES ARE COMBINATION PASSENGER AND FREIGHT ELEVATORS, THEY SHALL COMPLY WITH SECTION 11B-407 AND WITH ASME A17.1. [11B-407.1.1] 3. CALL BUTTONS & KEYPADS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN 11B-308 MEASURED TO THE CENTERLINE OF THE HIGHEST OPERABLE PART. [11B-407.2.1.1] 4. CALL BUTTONS SHALL HAVE SQUARE SHOULDERS, BE 3/4 INCH MINIMUM IN THE SMALLEST DIMENSION AND SHALL BE RAISED 1/8" PLUS OR MINUS 1/32 INCH ABOVE THE SURROUNDING SURFACE. THE BUTTONS SHALL BE ACTIVATED BY A MECHANICAL MOTION THAT IS DETECTABLE. [11B-407.2.1.2] 5. CLEAR FLOOR SPACE COMPLYING WITH 11B-305 SHALL BE PROVIDED AT CALL CONTROLS. [11B-407.2.1.3] 6. THE CALL BUTTON THAT DESIGNATES THE UP DIRECTION SHALL BE LOCATED ABOVE THE CALL BUTTON THAT DESIGNATES THE DOWN DIRECTION. [11B-407.2.1.4] 7. CALL BUTTONS SHALL HAVE VISIBLE SIGNALS THAT WILL ACTIVATE WHEN EACH CALL IS REGISTERED AND WILL EXTINGUISH WHEN EACH CALL IS ANSWERED. CALL BUTTONS SHALL BE INTERNALLY ILLUMINATED WITH A WHITE LIGHT OVER THE ENTIRE SURFACE OF THE BUTTON. [11B-407.2.1.5] 8. A VISIBLE AND AUDIBLE SIGNAL SHALL BE PROVIDED AT EACH HOIST WAY ENTRANCE TO INDICATE WHICH CAR IS ANSWERING A CALL AND THE CAR'S DIRECTION OF TRAVEL. WHERE IN-CAR SIGNALS ARE PROVIDED THEY SHALL VISIBLE FROM THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTONS. [11B-407.2.2.1] 9. VISIBLE SIGNALS FIXTURES SHALL BE CENTERED AT 72 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. THE VISIBLE SIGNAL ELEMENTS SHALL BE A MINIMUM 21/2 INCHES HIGH BY 21/2 INCHES WIDE. SIGNALS SHALL BE VISIBLE FROM THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTON. [11B-407.2.2.2] 10. AUDIBLE SIGNALS SHALL SOUND ONCE FOR THE UP DIRECTION AND TWICE FOR THE DOWN DIRECTION, OR SHALL HAVE VERBAL ANNUNCIATORS THAT INDICATE THE DIRECTION OF ELEVATOR CALL TRAVEL. AUDIBLE SIGNALS SHALL HAVE A FREQUENCY OF 1500 Hz MAXIMUM. VERBAL ANNUNCIATORS SHALL HAVE A FREQUENCY OF 300 Hz MINIMUM AND 3,000 Hz MAXIMUM. THE AUDIBLE SIGNAL AND VERBAL ANNUNCIATORS SHALL BE 10 dB MINIMUM ABOVE AMBIENT, BUT SHALL NOT EXCEED 80 dB, MEASURED AT THE HALL CALL BUTTON. [11B-407.2.2.3] 11. FLOOR DESIGNATIONS SHALL BE PROVIDED ON BOTH JAMBS OF ELEVATOR HOISTWAY ENTRANCES. FLOOR DESIGNATIONS SHALL BE PROVIDED IN BOTH RAISED CHARACTERS AND BRAILLE. RAISED CHARACTERS SHALL BE 2 INCHES HIGH. A RAISED STAR, PLACED TO THE LEFT OF THE FLOOR DESIGNATION, SHALL BE PROVIDED ON BOTH JAMBS AT THE MAIN ENTRY LEVEL. THE OUTSIDE DIAMETER OF THE STAR SHALL BE 2 INCHES AND ALL POINTS SHALL BE OF EQUAL LENGTH. RAISED CHARACTERS, INCLUDING THE STAR, SHALL BE WHITE ON A BLACK BACKGROUND, BRAILLE COMPLYING WITH SECTION 11B-703.3 SHALL BE PLACED BELOW THE CORRESPONDING RAISED CHARACTERS AND THE STAR. THE BRAILLE TRANSLATION FOR THE STAR SHALL BE "MAIN". APPLIED PLATES ARE ACCEPTABLE IF THEY ARE PERMANENTLY FIXED TO THE JAMB. [11B-407.2.3.1] 12. ELEVATOR DOOR REQUIREMENTS. ELEVATOR DOORS SHALL BE THE HORIZONTAL SLIDING TYPE. CAR GATES SHALL BE PROHIBITED. ELEVATOR AND HOISTWAY DOORS SHALL OPEN AND CLOSE AUTOMATICALLY. EXCEPTION: EXISTING MANUALLY OPERATED HOISTWAY SWING DOORS SHALL BE PERMITTED PROVIDED THEY COMPLY WITH CLEAR DOOR WIDTH AND OPENING FORCE REQUIREMENTS AND THE CAR DOOR CLOSING IS NOT INITIATED UNTIL THE HOISTWAY DOOR IS CLOSED. [11B-407.3.1 AND 11B-407.3.2] 13. REOPENING DEVICE. ELEVATOR DOORS SHALL BE PROVIDED WITH A REOPENING DEVICE THAT SHALL STOP AND REOPEN A CAR DOOR AND HOISTWAY DOOR AUTOMATICALLY IF THE DOOR BECOMES OBSTRUCTED BY AN OBJECT OR PERSON. EXCEPTION: IN EXISTING ELEVATORS MANUALLY OPERATED DOORS SHALL NOT BE REQUIRED TO COMPLY. [11B-407.3.3] 14. THE REOPENING DEVICE SHALL BE ACTIVATED BY SENSING AN OBSTRUCTION PASSING THROUGH THE OPENING AT 5 INCHES NOMINAL AND 29 INCHES NOMINAL ABOVE THE FINISH FLOOR. THE REOPENING DEVICE SHALL NOT REQUIRE PHYSICAL CONTACT TO BE ACTIVATED, ALTHOUGH CONTACT SHALL BE PERMITTED BEFORE THE DOOR REVERSES. THE REOPENING DEVICE SHALL REMAIN EFFECTIVE TO 20 SECONDS MINIMUM. [11B-407.3.3.1 - 11B-407.3.3.3] 15. DOOR AND SIGNAL TIMING. THE MINIMUM ACCEPTABLE TIME FROM NOTIFICATION THAT A CAR IS ANSWERING A CALL UNTIL THE DOORS OF THAT CAR START TO CLOSE SHALL BE CALCULATED FROM THE FOLLOWING EQUATION: T=D/(1.5 FT/S) OR T=D/(457 MM/S) = 5 SECONDS MINIMUM WHERE T EQUALS THE TOTAL TIME IN SECONDS AND D EQUALS THE DISTANCE FROM THE POINT IN THE LOBBY OR CORRIDOR 60 INCHES DIRECTLY IN FRONT OF THE FARTHEST CALL BUTTON CONTROLLING THAT CAR TO THE CENTERLINE OF ITS HOISTWAY DOOR. EXCEPTION: FOR CARS WITH IN-CAR LANTERNS, T SHALL BE PERMITTED TO BEGIN WHEN THE SIGNAL IS VISIBLE FROM THE POINT 60 IN INCHES DIRECTLY IN FRONT OF THE FARTHEST HALL CALL BUTTON AND THE AUDIBLE SIGNAL IS SOUNDED. [11B-407.3.4] 16. DOOR DELAY: ELEVATOR DOORS SHALL REMAIN FULLY OPEN IN RESPONSE TO A CAR CALL FOR 5 SECONDS MINIMUM. [11B-407.3.5] 17. DOOR WIDTH: SHALL COMPLY WITH TABLE 11B-407.4.1. EXCEPTION: IN EXISTING ELEVATORS, A POWER-OPERATED CAR DOOR WITH A CLEAR WIDTH OF 32 INCHES MINIMUM SHALL BE PERMITTED. [11B-407.3.6] 18. CAR DIMENSIONS. INSIDE DIMENSIONS OF ELEVATOR CARS AND CLEAR WIDTH OF ELEVATOR DOORS SHALL COMPLY WITH TABLE 11B-407.4.1. EXCEPTION: IN EXISTING BUILDINGS, WHERE EXISTING SHAFT CONFIGURATION PROHIBITS STRICT COMPLIANCE, EXISTING ELEVATOR CAR CONFIGURATIONS THAT PROVIDE A CLEAR FLOOR AREA OF 18 SQUARE FEET MINIMUM AND ALSO PROVIDE AN INSIDE CLEAR DEPTH OF 54 INCHES MINIMUM AND A CLEAR WIDTH OF 48 INCHES MINIMUM SHALL BE PERMITTED. [11B-407.4.1] 19. FLOOR SURFACES IN ELEVATOR CARS SHALL BE STABLE, FIRM AND SLIP RESISTANT, AND SHALL COMPLY WITH SECTIONS 11B-302 AND 11B-303. [11B-407.4.1] 20. PLATFORM TO HOISTWAY CLEARANCE: THE CLEARANCE BETWEEN THE CAR PLATFORM SILL AND THE EDGE OF ANY HOISTWAY LANDING SHALL BE 11/4 INCH MAXIMUM. [11B-407.4.3] 21. LEVELING: EACH CAR SHALL BE EQUIPPED WITH A SELF-LEVELING FEATURE THAT WILL AUTOMATICALLY BRING AND MAINTAIN THE CAR AT FLOOR LANDINGS WITHIN A TOLERANCE OF 1/2 INCH UNDER RATED LOADING TO ZERO LOADING CONDITIONS. [11B-407.4.4] 22. ILLUMINATION. THE LEVEL OF ILLUMINATION AT THE CAR CONTROLS, PLATFORM, CAR THRESHOLD AND CAR LANDING SILL SHALL BE 5 FOOT-CANDELS (54 LUX) MINIMUM. [11B-407.4.5] 23. ELEVATOR CAR CONTROLS, WHERE PROVIDED, ELEVATOR CAR CONTROLS SHALL CONFORM WITH OPERABLE PARTS REQUIREMENTS. EXCEPTION: IN EXISTING ELEVATORS, WHERE A NEW CAR OPERATING PANEL IS PROVIDED, EXISTING CAR OPERATING PANELS MAY REMAIN OPERATIONAL AND SHALL NOT BE REQUIRED TO COMPLY. [11B-407.4.6] 24. CONTROL LOCATION: CONTROLS SHALL BE LOCATED WITHIN ONE OF THE REQUIRED REACH RANGES. EXCEPTION: WHERE THE ELEVATOR PANEL SERVES MORE THAN 16 OPENINGS AND A PARALLEL APPROACH IS PROVIDED, BUTTONS WITH FLOOR DESIGNATIONS SHALL BE PERMITTED TO BE 54 INCHES MAXIMUM ABOVE THE FINISH FLOOR; OR IN EXISTING ELEVATORS, CAR CONTROL BUTTONS WITH FLOOR DESIGNATIONS SHALL BE PERMITTED TO BE LOCATED 54 INCHES MAXIMUM ABOVE THE FINISH FLOOR WHERE A PARALLEL APPROACH IS PROVIDED. [11B-407.4.6.1] 25. BUTTONS. BUTTONS SHALL HAVE SQUARE SHOULDERS, BE 3/4 INCH MINIMUM IN THEIR SMALLEST DIMENSION AND BE RAISED 1/8 INCH PLUS OR MINUS 1/32 INCH ABOVE THE SURROUNDING SURFACE. BUTTONS SHALL BE ARRANGED WITH NUMBERS IN ASCENDING ORDER. WHEN TWO OR MORE COLUMNS OF BUTTONS ARE PROVIDED THEY SHALL READ FROM LEFT TO RIGHT. CAR CONTROL BUTTONS SHALL BE ILLUMINATED. CAR CONTROL BUTTONS SHALL BE ACTIVATED BY A MECHANICAL MOTION THAT IS DETECTABLE. [11B-407.4.6.2.1 - 11B-407.4.6.2.4] 26. KEYPADS: CAR CONTROL KEYPADS SHALL BE IN A STANDARD TELEPHONE KEYPAD ARRANGEMENT. [11B-407.4.6.3] 27. EMERGENCY CONTROLS BUTTONS SHALL HAVE THEIR CENTERLINES 35 INCHES MINIMUM ABOVE THE FINISH FLOOR. EMERGENCY CONTROLS, INCLUDING THE EMERGENCY ALARM, SHALL BE GROUPED AT THE BOTTOM OF THE PANEL. [11B-407.4.6.4.1 AND 11B-407.4.6.4.2] 28. DESIGNATIONS AND INDICATORS OF CAR CONTROLS. CONTROL BUTTONS SHALL BE IDENTIFIED BY RAISED CHARACTERS OR SYMBOLS, WHITE ON A BLACK BACKGROUND, COMPLYING WITH SECTION 1 1B-703.2 AND BRAILLE COMPLYING WITH SECTION 11B-703.3. RAISED CHARACTERS OR SYMBOLS AND BRAILLE DESIGNATIONS SHALL BE PLACED IMMEDIATELY TO THE LEFT OF THE CONTROL BUTTON TO WHICH THE DESIGNATIONS APPLY. A MINIMUM CLEAR SPACE OF 3/8 INCH OR OTHER SUITABLE MEANS OF SEPARATION SHALL BE PROVIDED BETWEEN ROWS OF CONTROL BUTTONS. [11B-407.4.7.1.1, 1 1B-407.4.7.1.2 AND 11B-407.4.7.1.5] 29. SYMBOLS. THE CONTROL BUTTON FOR THE EMERGENCY STOP, ALARM, DOOR OPEN, DOOR CLOSE, MAIN ENTRY FLOOR, AND PHONE, SHALL BE IDENTIFIED WITH RAISED SYMBOLS AND BRAILLE AS SHOWN IN TABLE 11B-407.4.7.1.3. [11B-407.4.7.1.3] 30. VISIBLE INDICATORS. BUTTONS WITH FLOOR DESIGNATIONS SHALL BE PROVIDED WITH VISIBLE INDICATORS TO SHOW THAT A CALL HAS BEEN REGISTERED. THE VISIBLE INDICATION SHALL EXTINGUISH WHEN THE CAR ARRIVES AT THE DESIGNATED FLOOR. [11B-407.4.7.1.4] 31. KEYPADS: KEYPADS SHALL BE IDENTIFIED BY VISUAL CHARACTERS COMPLYING WITH SECTION 11B-703.5 AND SHALL BE CENTERED ON THE CORRESPONDING KEYPAD BUTTON. THE NUMBER FIVE KEY SHALL HAVE A SINGLE RAISED DOT. THE DOT SHALL BE 0.118 INCH TO 0.120 INCH BASE DIAMETER AND IN OTHER ASPECTS COMPLY WITH TABLE 11B-703.3.1. [11B-407.4.7.2] 32. CAR POSITION INDICATORS; AUDIBLE AND VISIBLE CAR POSITION INDICATORS SHALL BE PROVIDED IN ELEVATOR CARS. CHARACTERS SHALL BE 1/2 INCH HIGH MINIMUM. INDICATORS SHALL BE LOCATED ABOVE THE CAR CONTROL PANEL OR ABOVE THE DOOR. AS THE CAR PASSES A FLOOR AND WHEN A CAR STOPS AT A FLOOR SERVED BY THE ELEVATOR, THE CORRESPONDING CHARACTER SHALL I LLUMINATE, AUDIBLE INDICATORS: THE SIGNAL SHALL BE AN AUTOMATIC VERBAL ANNUNCIATOR WHICH THE ANNOUNCES THE FLOOR AT WHICH THE CAR IS ABOUT TO STOP. THE VERBAL ANNUNCIATOR SHALL BE 10 dB MINIMUM ABOVE AMBIENT, BUT SHALL NOT EXCEED 80 dB, MEASURED AT THE ANNUNCIATOR. THE VERBAL ANNUNCIATOR SHALL HAVE A FREQUENCY OF 300 Hz MINIMUM TO 3,000 Hz MAXIMUM. EXCEPTION: FOR ELEVATORS THAT HAVE A RATED SPEED OF 200 FEET PER MINUTE OR LESS, A NON-VERBAL AUDIBLE SIGNAL WITH A FREQUENCY OF 1500 Hz MAXIMUM WHICH SOUNDS AS THE CAR PASSES OR IS ABOUT TO STOP AT A FLOOR SERVED BY THE ELEVATOR SHALL BE PERMITTED. [11B-407.4.8 - 11B407.4.8.2.3] 33. EMERGENCY TWO-WAY COMMUNICATIONS; RAISED SYMBOLS OR CHARACTERS, WHITE ON A BLACK BACKGROUND, AND BRAILLE SHALL BE PROVIDED ADJACENT TO THE DEVICE AND SHALL COMPLY WITH SECTIONS 11B-703.2 AND 11B-703.3. EMERGENCY TWO-WAY COMMUNICATION SYSTEMS BETWEEN THE ELEVATOR AND A POINT OUTSIDE THE HOISTWAY SHALL COMPLY WITH ASME A17.1. [11B-407.4.9] 34. SUPPORT RAIL: SUPPORT RAILS SHALL BE PROVIDED ON AT LEAST ONE WALL OF THE CAR. CLEARANCE BETWEEN SUPPORT RAILS AND ADJACENT SURFACES SHALL BE 1-1/2 INCHES MINIMUM. TOP OF SUPPORT RAILS SHALL BE 31 INCHES MINIMUM TO 33 INCHES MAXIMUM ABOVE THE FLOOR OF THE CAR. THE ENDS OF THE SUPPORT RAIL SHALL BE 6 INCHES MAXIMUM FROM ADJACENT WALLS. SUPPORT RAILS SHALL BE SMOOTH AND ANY SURFACE ADJACENT TO THEM SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE SUPPORT RAIL, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. [11B-407.4.10] 35. PLATFORM LIFTS SHALL COMPLY WITH ASME A18.1. PLATFORM LIFTS SHALL NOT BE ATTENDANT-OPERATED AND SHALL PROVIDE UNASSISTED ENTRY AND EXIT FROM THE LIFT. [11B-410.1] 36. FLOOR SURFACES IN PLATFORM LIFTS SHALL COMPLY WITH SECTIONS 11B-302 AND 11B-303. [11B-410.2] 37. CLEAR FLOOR SPACE IN PLATFORM LIFTS SHALL COMPLY WITH SECTION 11B-305. [11B-410.3] 38. PLATFORM TO RUNWAY CLEARANCE: THE CLEARANCE BETWEEN THE PLATFORM SILL AND THE EDGE OF ANY RUNWAY LANDING SHALL BE 1-1/4 INCH MAXIMUM. [11B-410.4] 39. OPERABLE PARTS: CONTROLS FOR PLATFORM LIFTS SHALL COMPLY WITH REQUIRED REACH RANGES. [11B-410.5] 40. DOORS AND GATES: PLATFORM LIFTS SHALL HAVE LOW-ENERGY POWER-OPERATED DOORS OR GATES COMPLYING WITH SECTION 11B-404.3. DOORS SHALL REMAIN OPEN FOR 20 SECONDS MINIMUM. END DOORS AND GATES SHALL PROVIDE A CLEAR WIDTH 32 INCHES MINIMUM. SIDE DOORS AND GATES SHALL PROVIDE A CLEAR WIDTH 42 INCHES MINIMUM. EXCEPTION: PLATFORM LIFTS SERVING TWO LANDINGS MAXIMUM AND HAVING DOORS OR GATES ON OPPOSITE SIDES SHALL BE PERMITTED TO HAVE SELF-CLOSING MANUAL DOORS OR GATES. [11B-410.6] 41. LANDING SIZE: THE MINIMUM SIZE OF LANDINGS AT PLATFORM LIFTS SHALL BE 60 INCHES BY 60 INCHES MINIMUM. [11B-410.7] 42. RESTRICTION SIGN: A SIGN COMPLYING WITH SECTION 11B-703.5 SHALL BE POSTED IN A CONSPICUOUS PLACE AT EACH LANDING AND WITHIN THE PLATFORM ENCLOSURE STATING "NO FREIGHT" AND INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. [11B-410.8] TWO-WAY COMMUNICATION NOTES (PER CBC 1009.8): A. A TWO-WAY COMMUNICATIONS SYSTEM SHALL BE PROVIDED AT THE LANDING SERVING EACH ELEVATOR OR BANK OF ELEVATORS ON EACH ACCESSIBLE FLOOR THAT IS ONE OF MORE STORIES ABOVE OR BELOW THE LEVEL OF EXIT DISCHARGE (OR MEET ONE OF THE EXCEPTIONS LISTED IN CBC SECTION 1009.8) B. SYSTEM REQUIREMENTS. TWO-WAY COMMUNICATION SHALL PROVIDE COMMUNICATION BETWEEN EACH REQUIRED LOCATION AND THE FIRE COMMAND CENTER OR A CENTRAL CONTROL POINT LOCATION APPROVED BY THE FIRE DEPARTMENT. WHERE THE CENTRAL CONTROL POINT IS NOT A CONSTANTLY ATTENDED LOCATION, A TWO-WAY COMMUNICATION SYSTEM SHALL HAVE A TIMED AUTOMATIC TELEPHONE DIAL-OUT CAPABILITY THAT PROVIDES TWO-WAY COMMUNICATION WITH AN APPROVED SUPERVISING STATION OR 9-1-1. TWO-WAY COMMUNICATION SHALL INCLUDE BOTH AUDIBLE AND VISIBLE SIGNALS. [1009.8.1] C. VISIBLE COMMUNICATION METHODS. A BUTTON LOCATED IN THE AREA OF REFUGE SHALL ACTIVATE BOTH A LIGHT IN THE AREA OF REFUGE INDICATING THAT RESCUE HAS BEEN REQUESTED AND A LIGHT AT THE CENTRAL CONTROL POINT INDICATING THAT RESCUE HAS BEEN REQUESTED. A BUTTON AT THE CENTRAL CONTROL POINT SHALL ACTIVATE BOTH A LIGHT AT THE CENTRAL CONTROL POINT AND A LIGHT IN THE AREA OF REFUGE INDICATING THAT THE REQUEST HAS BEEN RECEIVED. ALL OPERABLE PARTS SHALL BE PLACED WITHIN ONE OF MORE OF THE REACH RANGES, SHALL BE PROVIDED WITH A CLEAR FLOOR SPACE OR GROUND SPACE AND SHALL BE OPERABLE WITH ONE HAND NOT REQUIRING TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE MAXIMUM FORCE REQUIRED TO ACTIVATE THE OPERABLE PARTS SHALL NOT EXCEED 5 POUNDS. [1009.8.1.1] D. DIRECTIONS. DIRECTIONS FOR THE USE OF THE TWO-WAY COMMUNICATION SYSTEM, INSTRUCTIONS FOR SUMMONING ASSISTANCE VIA THE TWO-WAY COMMUNICATION SYSTEM, AND WRITTEN IDENTIFICATION OF THE LOCATION SHALL BE POSTED ADJACENT TO TWO-WAY COMMUNICATION. SIGNAGE SHALL COMPLY WITH DETAIL 17 - COMMUNICATION ELEMENTS AND FEATURES FOR VISUAL CHARACTERS REQUIREMENTS. [1009.8.2] 1. HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS. [11B-505.2] EXCEPTIONS: 1. IN ASSEMBLY AREAS, HANDRAILS SHALL NOT BE REQUIRED ON BOTH SIDES OF AISLE RAMPS WHERE A HANDRAIL IS PROVIDED AT EITHER SIDE OR WITHIN THE AISLE WIDTH. 2. CURB RAMPS DO NOT REQUIRE HANDRAILS. 3. AT DOOR LANDINGS, HANDRAILS ARE NOT REQUIRED WHEN THE RAMP RUN IS LESS THAN 6 INCHES IN RISE OR 72 INCHES IN LENGTH. 2. HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS OR RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS. [11B-505.3] 3. GRIPPING SURFACES SHALL BE CONTINUOUS ALONG THEIR LENGTH AND SHALL NOT BE OBSTRUCTED ALONG THEIR TOPS OR SIDES. THE BOTTOMS OF THE HANDRAIL GRIPPING SURFACE SHALL NOT BE OBSTRUCTED FOR MORE THAN 20 PERCENT THEIR LENGTH. WHERE PROVIDED, HORIZONTAL PROJECTIONS SHALL OCCUR 1 1/2 INCHES MINIMUM BELOW THE BOTTOM OF THE HANDRAIL GRIPPING SURFACE. [11B-505.6] EXCEPTIONS: 1. WHERE HANDRAILS ARE PROVIDED ALONG WALKING SURFACES WITH SLOPES NOT STEEPER THAN 1:20, THE BOTTOMS OF HANDRAIL GRIPPING SURFACES SHALL BE PERMITTED TO BE OBSTRUCTED ALONG THEIR ENTIRE LENGTH WHERE THEY ARE INTEGRAL TO CRASH RAILS OR BUMPER GUARDS. 2. THE DISTANCE BETWEEN HORIZONTAL PROJECTIONS AND THE BOTTOM OF THE GRIPPING SURFACE SHALL BE PERMITTED TO BE REDUCED BY 1/8 INCH FOR EACH 1/2 INCH OF ADDITIONAL HANDRAIL PERIMETER DIMENSION THAT EXCEEDS 4 INCHES. 4. HANDRAIL GRIPPING SURFACE AND ANY SURFACES ADJACENT TO THEM SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS AND SHALL HAVE ROUNDED EDGES. [11B-505.8] 5. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS. [11B-505.9] 6. HANDRAIL GRIPPING SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION OF STAIR FLIGHTS AND RAMP RUNS. [11B-505.10] EXCEPTIONS; 1. EXTENSIONS SHALL NOT BE REQUIRED FOR CONTINUOUS HANDRAILS AT THE INSIDE TURN OF SWITCH BACK OR DOGLEG STAIRS AND RAMPS. 2. IN ASSEMBLY AREAS, EXTENSIONS SHALL NOT BE REQUIRED FOR RAMP HANDRAILS IN AISLE SERVING SEATING WHERE THE HANDRAILS ARE DISCONTINUOUS TO PROVIDE ACCESS TO SEATING AND TO PERMIT CROSSOVERS WITHIN AISLES. 3. IN ALTERATIONS, WHERE THE EXTENSION OF THE HANDRAIL IN THE DIRECTION OF STAIR FLIGHT OR RAMP RUN WOULD CREATE A HAZARD, THE EXTENSION OF THE HANDRAIL MAY BE TURNED 90 DEGREES FROM THE DIRECTION OF THE STAIR FLIGHT OR RAMP RUN. 7. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT OR RAMP RUN. [11B-505.10.1 & 11B-505.10.2] 8. PROJECTS INTO THE REQUIRED WIDTH OF AISLES, STAIRWAYS, AND RAMPS AT EACH SIDE SHALL NOT EXCEED 4 1/2" AT OR BELOW HANDRAIL HEIGHT. [1014.8] NOTES: 1. TREADS AND RISERS: ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTHS. RISERS SHALL BE 4 INCHES HIGH MINIMUM AND 7 INCHES HIGH MAXIMUM. TREADS SHALL BE 11 INCHES DEEP MINIMUM. [11B-504.2] 2. OPEN RISERS SHALL NOT BE PERMITTED. [11B-504.3] 3. TREADS SHALL COMPLY WITH FLOOR SURFACES, SHALL HAVE A SLOPE NOT STEEPER THAN 1:48, AND DETECTABLE WARNINGS SHALL NOT BE PERMITTED. [11B-504.4] 4. CONTRASTING STRIPE. INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. THE STRIPE SHALL BE 2-4 INCHES WIDE PLACED PARALLEL TO AND NOT MORE THAN 1 INCH FROM THE NOSE OF THE STEP OR UPPER APPROACH. THE STRIPE SHALL EXTEND THE FULL WIDTH OF THE STEP OR UPPER APPROACH AND SHALL BE OF MATERIAL THAT IS AS LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE. GROOVES SHALL NOT BE USED TO SATISFY THIS REQUIREMENT. [11B-504.4.1] 5. NOSINGS. THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE 1/2 INCH MAXIMUM. NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED. RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAXIMUM FROM VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL EXTEND 11/4 INCHES MAXIMUM OVER TREAD BELOW. [11B-504.5] 6. HANDRAILS. STAIRS SHALL HAVE COMPLYING HANDRAILS. [11B-504.6] 7. WET CONDITIONS. STAIR TREADS AND LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. [11B-504.7] 8. FLOOR IDENTIFICATION SIGNS REQUIRED BY CHAPTER 10, SECTION 1023.9 SHALL BE LOCATED AT THE LANDING OF EACH FLOOR LEVEL, PLACED ADJACENT TO THE DOOR ON THE LATCH SIDE, IN ALL ENCLOSED STAIRWAYS IN BUILDINGS TWO OR MORE STORIES IN HEIGHT TO IDENTIFY THE FLOOR LEVEL. AT THE EXIT DISCHARGE LEVEL, THE SIGN SHALL INCLUDE A RAISED FIVE POINTED STAR LOCATED TO THE LEFT OF THE IDENTIFYING FLOOR LEVEL. THE OUTSIDE DIAMETER OF THE STAR SHALL BE THE SAME AS THE HEIGHT OF THE RAISED CHARACTERS. [11B-504.8] 1. WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL COMPLY. IN ADDITION, WHERE WORK SURFACES ARE PROVIDED FOR USE BY OTHER THAN EMPLOYEES, AT LEAST 5 PERCENT SHALL COMPLY. [11B-226.1] 2. DINING SURFACES AND WORK SURFACES REQUIRED TO COMPLY SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING SURFACES AND WORK SURFACES FOR EACH TYPE OF SEATING IN A FUNCTIONAL AREA. [11B-226.2] 3. A CLEAR FLOOR SPACE POSITIONED FOR A FORWARD APPROACH WITH KNEE AND TOE CLEARANCE SHALL BE PROVIDED. [11B-902.2] 4. THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE 28" MIN. AND 34" MAX. ABOVE THE FINISH FLOOR OR GROUND. [11B-902.3] 5. DINING SURFACES EXCEEDING 34 INCHES IN HEIGHT. WHERE FOOD OR DRINK IS SERVED FOR CONSUMPTION AT A COUNTER EXCEEDING 34 INCHES IN HEIGHT, A PORTION OF THE MAIN COUNTER 60 INCHES MINIMUM IN LENGTH SHALL BE PROVIDED. [11B-226.3] 6. BABY AND CHANGING TABLES SHALL COMPLY WITH OPERABLE PARTS AND WORK SURFACES. SEE TOILET COMPARTMENTS FOR ADDITIONAL INFORMATION. [11B-226.4] NOTES 1. KITCHEN WORK SURFACE SHALL BE 34 INCHES MAX ABOVE THE FINISH FLOOR. [11B-804.3.2] 2. AT LEAST 50% OF SHELF SPACE IN STORAGE FACILITIES SHALL BE ACCESSIBLE. [11B-804.5] 3. SINKS SHALL BE ACCESSIBLE. EXCEPTION: A PARALLEL APPROACH SHALL BE PERMITTED TO A KITCHEN SINK IN A SPACE WHERE A COOK TOP OR RANGE IS NOT PROVIDED.[11B-606.2] 4. A CLEAR FLOOR SPACE SHALL BE PROVIDED AT EACH APPLIANCE. [11B-804.6.1] 5. DISHWASHER: CLEAR FLOOR OR GROUND SPACE SHALL BE POSITIONED ADJACENT TO THE DISHWASHER DOOR. THE DISHWASHER DOOR, IN THE OPEN POSITION, SHALL NOT OBSTRUCT THE CLEAR FLOOR OR GROUND SPACE FOR THE DISHWASHER OR THE SINK. [11B-804.6.3] 6. COMBINATION REFRIGERATOR/FREEZER SHALL HAVE AT LEAST 50% OF THE FREEZER SPACE 54 INCHES MAX ABOVE THE FINISHED FLOOR. [11B-804.6.6] NOTES: 1. CLEAR FLOOR OR GROUND SPACE SHALL BE PROVIDED AND SHALL BE POSITIONED AT THE END OF THE BENCH SEAT AND PARALLEL TO THE SHORT AXIS OF THE BENCH. [11B-903.2] 2. BENCHES SHALL BE AFFIXED TO THE WALL OR FLOOR. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE SEAT, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. [11B-903.6] 3. WHERE INSTALLED IN WET LOCATIONS THE SURFACE OF THE SEAT SHALL BE SLIP RESISTANT AND SHALL NOT ACCUMULATE WATER. [11B-903.7] 4. THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL ALONG ITS LONG DIMENSION AND SHALL BE 48 INCHES LONG MIN. [11B-903.4] WHERE REQUIRED: TACTILE EXIT SIGNS SHALL BE REQUIRED AT THE FOLLOWING LOCATIONS: [11B-1013.4] 1. EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORD, "EXIT". 2. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE: "EXIT STAIR DOWN", "EXIT RAMP DOWN", "EXIT STAIR UP", "EXIT RAMP UP" 3. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS, "EXIT ROUTE". 4. EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN, SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS, "EXIT ROUTE". 5. EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A SIGN WITH THE WORDS, "TO EXIT". REFER TO COMMUNICATION ELEMENTS 11B-703 FOR RAISED CHARACTER AND BRAILLE DESCRIPTION/DEFINITION 1. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12. [11B-405.2] 2. CROSS SLOPE OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48. [11B-405.3] CHANGES IN LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE NOT PERMITTED ON RAMP RUNS. [11B-405.4] 3. RAMP RUNS SHALL COMPLY WITH FLOOR SURFACES. [11B-405.4] 4. THE CLEAR WIDTH OF A RAMP RUN SHALL BE 48 INCHES MINIMUM. [11B-405.5] HANDRAILS MAY PROJECT INTO THE REQUIRED CLEAR WIDTH OF THE RAMP AT EACH SIDE 3-1/2" MAXIMUM AT THE HANDRAIL HEIGHT. [11B-405.5] 5. THE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES MAXIMUM. [11B-405.6] 6. RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE BOTTOM OF EACH RAMP RUN. LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 1:48 AND SHALL COMPLY WITH FLOOR SURFACES. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. THE TOP LANDING SHALL BE 60 INCHES WIDE MINIMUM. THE LANDING CLEAR LENGTH SHALL BE 60 INCHES LONG MINIMUM. BOTTOM LANDINGS SHALL EXTEND 72 INCHES MINIMUM. [11B-405.7] 7. RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING 60 INCHES MINIMUM BY 72 INCHES MINIMUM IN THE DIRECTION OF DOWNWARD TRAVEL FROM THE UPPER RAMP RUN. [11B-405.7.4] 8. HANDRAILS: RAMP RUNS SHALL HAVE HANDRAILS. CURB RAMPS DO NOT REQUIRE HANDRAILS. AT DOOR LANDINGS, HANDRAILS ARE NOT REQUIRED ON RAMP RUNS LESS THAN 6 INCHES IN RISE OR 72 INCHES IN LENGTH. [11B-405.8] 9. EDGE PROTECTION SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. [11B-405.9] EXCEPTIONS: 1. EDGE PROTECTION SHALL NOT BE REQUIRED AT CURB RAMPS. 2. EDGE PROTECTION SHALL NOT BE REQUIRED ON THE SIDES OF RAMP LANDINGS SERVING AN ADJOINING RAMP RUN OR STAIRWAY. 3. EDGE PROTECTION SHALL NOT BE REQUIRED ON THE SIDES OF RAMP LANDINGS HAVING A VERTICAL DROP-OFF OF 1/2 INCH MAXIMUM WITHIN 10 INCHES HORIZONTALLY OF THE MINIMUM LANDING AREA. 10. A CURB, 2 INCHES HIGH MINIMUM, OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4 INCH DIAMETER SPHERE, WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR OR GROUND SURFACE. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE A CONTINUOUS AND UNINTERRUPTED BARRIER ALONG THE LENGTH OF THE RAMP. [11B-405.9.2] 11. LANDING SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. [11B-405.10] NOTES: 1. RAISED CHARACTER AND BRAILLE FLOOR IDENTIFICATION SIGNS SHALL BE LOCATED AT THE LANDING OF EACH FLOOR LEVEL, PLACED ADJACENT TO THE DOOR ON THE LATCH SIDE, IN ALL ENCLOSED STAIRWAYS IN BUILDINGS TWO OR MORE STORES IN HEIGHT TO IDENTIFY THE FLOOR LEVEL. [1023.9] 2. AT THE EXIT DISCHARGE LEVEL, THE SIGN SHALL INCLUDE A RAISED FIVE-POINTED STAR LOCATED TO THE LEFT OF THE IDENTIFYING FLOOR LEVEL. THE OUTSIDE DIAMETER OF THE STAR SHALL BE THE SAME AS THE HEIGHT OF THE RAISED CHARACTERS. [1023.9] 3. SIGN SHALL BE POSITIONED SO THAT IT IS READILY VISIBLE WHEN THE DOORS ARE IN THE OPEN AND CLOSED POSITIONS. [1023.9] 4. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND, WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. [1023.9.1] 5. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE: "EXIT STAIR DOWN", "EXIT RAMP DOWN", "EXIT STAIR UP", "EXIT RAMP DOWN". [1013.4] 6. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALL BE IDENTIFIED WITH A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE". [1013.4] 7. EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO COMPLY WITH SECTION 1013.1 SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE". [1013.4] 8. EACH EXIT DOOR THROUGH A HORIZONTAL EXIT THAT IS REQUIRED TO COMPLY WITH SECTION 1013.1 SHALL BE IDENTIFIED BY A SIGN WITH THE WORDS "TO EXIT". [1013.4] REFER TO COMMUNICATION ELEMENTS AND FEATURES FOR SIGNAGE REQUIREMENTS REGARDING FINISH & CONTRAST, RAISED CHARACTER & BRAILLE AND COMPLY WITH 11B-703.1, 703.2, 703.3 AND 703.5. ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 LEGEND -EGRESS PLAN FIRE EXTINGUISHER EMERGENCY EGRESS LIGHT 1. SEE COVER SHEET G-100 FOR BUILDING CODE INFORMATION. 2. SEE G-SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS AND DETAILS. GENERAL NOTES -EGRESS PLAN KEYNOTES -EGRESS PLAN 1 SIGN VENDOR TO PROVIDE AND INSTALL TACTILE UNISEX RESTROOM TACTILE AND DOOR IDENTIFICATION SIGNS. SEE DETAIL 17/G-103. 3 SIGN VENDOR TO PROVIDE AND INSTALL TACTILE "EXIT ROUTE" SIGN. SEE DETAIL 3/G-104. EXISTING WALL OR CONSTRUCTION TO REMAIN NEW WALL OR CONSTRUCTION, SEE PARTITION TYPE SCHEDULE NEW DEMOUNTABLE PARTITION SYSTEM BY FURNITURE VENDOR, SEE PARTITION TYPE SCHEDULE AREA NOT IN CONTRACT (N.I.C.) NAME ###ROOM NAME AND NUMBER #KEYNOTE EGRESS PATH FEC 2 SIGN VENDOR TO PROVIDE AND INSTALL TACTILE "EXIT" SIGN AT ENTRANCE DOORS. SEE DETAIL 3/G-104. OCCUPANT LOAD CALCULATIONS (TABLE 1004.5) OCCUPANCY CLASSIFICATION (CHAPTER 3) : B - BUSINESS FUNCTION OF SPACE : BUSINESS AREAS OCCUPANT LOAD FACTOR : 150 GROSS GROSS FLOOR AREA : 5,400 S.F. TOTAL OCCUPANTS : 36 NOTE: A ROOM OR SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD LESS THAN 50 PERSONS AND LESS THAN 750 S.F. THAT ARE ACCESSORY TO ANOTHER OCCUPANCY SHALL BE CLASSIFIED AS GROUP B OCCUPANCY. MEANS OF EGRESS SIZING (CBC SECTION 1005) EGRESS CAPACITY FACTOR (DOORS): 0.2" PER OCCUPANT MINIMUM WIDTH REQUIRED: 36 OCCUPANTS x 0.20" = 7.2" WIDTH PROVIDED:132" (EXISTING, NO CHANGE) MINIMUM NUMBER OF EXITS (CBC TABLE 1006.3.3) EXITS REQUIRED:2 EXITS PROVIDED:2 (EXISTING, NO CHANGE) EXIT SEPARATION (CBC SECTION 1007.1.1) MAXIMUM OVERALL DIAGONAL OF BUILDING: 115'-4" ONE-THIRD OF OVERALL DIAGONAL: 115'-4" / 3 = 38'-8" SEPARATION BETWEEN EXITS: 79'-10" (EXISTING, NO CHANGE) EXIT ACCESS TRAVEL DISTANCE (CBC TABLE 1017.2) ALLOWED:300'-0" ACTUAL:120'-7" PLUMBING FIXTURE CALCULATIONS (CPC TABLE 422.1) OCCUPANCY CLASSIFICATION: BUSINESS WATER CLOSETS LAVATORIES DRINKING FOUNTAIN SERVICE SINK REQUIRED PROVIDED REQUIRED PROVIDED REQUIRED PROVIDED REQUIRED PROVIDED MEN WOMEN 1 : 1-50 (NOTE 1)1 : 1-75 1 : 1-150 HI-LOW 1 HI-LOW 2 : 16-30 1 :1-50 1 1 NOTE: 1. TWO ALL-GENDER SINGLE OCCUPANCY RESTROOMS PROVIDED. ONE (1) ALL GENDER RESTROOM REQUIRED FOR BUSINESS OCCUPANCY WITH 50 TOTAL OCCUPANTS OR LESS PER SECTION 422.2, EXCEPTION 3. COMMON PATH OF EGRESS TRAVEL DISTANCE (CBC TABLE 1006.2.1) ALLOWED:100'-0" ACTUAL:71'-8" 4 LOCATION OF INTERIOR/EXTERIOR AUTOMATIC DOOR OPENER PUSH PLATE, SEE POWER AND DEVICE PLAN. OCCUPANT LOAD: 36 (18 MEN, 18 WOMEN) / EXISTING, NO CHANGE (NOTE 1) (NOTE 1) (NOTE 1) 5 AUTOMATIC LEAF DOOR. 6 EXISTING TACTILE "EXIT SIGN" 7 EXISTING INTERNATIONAL ACCESSIBILITY SYMBOL DECAL SIGN. 8 EXISTING DIRECTIONAL INTERNATIONAL ACCESSIBILITY SYMBOL SIGN. 9 SIGN VENDOR TO PROVIDE AND INSTALL INTERNATIONAL ACCESSIBILITY SYMBOL SIGN. SEE DETAIL 8/G-102. ELECTRICAL ROOM ELEVATOR EXIT SEPARATION: 79'-10" TRAVEL DISTANCE: 83' - 2" C.P.T.: 49' - 5" TR A V E L D I S T A N C E : 1 0 2 ' - 3 " C. P . T . : 7 1 ' - 8 " TRAVEL DISTANCE: 120' - 7" C.P.T.: 66' - 4" EXISTING EGRESS DOOR #101B WIDTH: 66" EXISTING EGRESS DOOR #100 WIDTH: 66" EGRESS DOOR #101A WIDTH: 66" 1 FEC 2ND LEVEL EGRESS STAIRS 2 3 2 109 MEETING ROOM 106 CMR.3 105 ATM / LAN ROOM 124 CMR.1 123 CMR.2 108 CMR.4 122 EMPLOYEE ENCLAVE 120 BM 117 EXISTING SD VAULT 104 WORK ROOM 114 UNIVERSAL RR 115 JANITOR CLOSET 113 RESTROOM 110 STAFF ROOM 119 COUPON BOOTH 116 CORRIDOR 107 RRB 100 COMMON VESTIBULE 121 AB 103 LOUNGE.2 102 LOUNGE.1 101 BANKING HALL 112 CORRIDOR 111 COAT CLOSET FEC 4'-0" 5'- 0 " 4' - 0 " 5'-0" O N E - T H I R D O F O V E R A L L D I A G O N A L: 3 8'-8" 1 1 5'-4" OFFICE USE AT TENANT ABOVE. NO SEPARATION REQUIRED FEC 5 1 1 6 7 8 9 1 1 1 1 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 EGRESS PLAN AND CODE ANALYSIS BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 1/4" = 1'-0" G-105 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 1/4" = 1'-0"EGRESS PLAN 1 1 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 LL 10/28/2024 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 CA GREEN CODE BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 01/30/24 222702550 G-106 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 X X X X X X X ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 CA GREEN CODE BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 01/30/24 222702550 G-107 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 X G.C.X G.C.X X X G.C.X X X X X G.C.X X X X X G.C.X G.C.X X ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 CA GREEN CODE BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 01/30/24 222702550 G-108 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 G.C.X G.C.X X G.C.X X X X G.C.X X G.C.X ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 EXISTING MULTI-TENANT TWO STORY BUILDING AREA OF BMO BANK RENOVATION (LEVEL 1 ONLY) TO OTHER RETAIL PADS1 HUNTINGTON DR. SU N S E T B L V D . CO R T E Z R D . 2 3 C2.0 1 LEGEND -SITE PLAN GENERAL NOTES -SITE PLAN EXISTING ACCESSIBLE PATH OF TRAVEL 1. EXISTING SITE PLAN IS FOR REFERENCE ONLY. REFER TO CIVIL DRAWINGS FOR EXTERIOR ACCESSIBILITY IMPROVEMENTS. SEE SHEETS G-102 & G-103 FOR SITE ACCESSIBILITY REQUIREMENTS. KEYNOTES -SITE PLAN 1 LOCATION OF THROUGH-WALL ATM AND SURROUND. REFER TO PLANS FOR DETAILS. 2 FOR ALL SITE WORK, SEE CIVIL DRAWINGS. 3 NEW NIGHT DEPOSIT DROP IN EXISTING OPENING. REFER TO PLANS FOR DETAILS #KEYNOTE PROPERTY LINE THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 OVERALL SITE PLAN BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 G-109 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 3/32" = 1'-0"OVERALL SITE PLAN 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 EXISTING BUILDING SU N S E T B L V D THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED ARCADIA, CA 91007 TITLE BMO CLIENT/PROJECT 1045 W. HUNTINGTON DRIVE, CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE AS NOTED Sheet DRAWING NO. PERMIT/SEAL STANTEC 224 SOUTH MICHIGAN AVE, SUITE 1400 CHICAGO, IL 60604 TEL:+1.312.554.1400• www.stantec.com KIMLEY-HORN 3801 UNIVERSITY AVE, STE 300 RIVERSIDE, CA 92501 Tel: +1.951.543.9868 CONSULTANT K: \ R I V _ L D E V \ B M O \ 0 9 4 6 1 5 3 6 6 - A R C A D I A \ C A D \ P L A N S H E E T S \ B M O A R C A D I A DE M O L I T I O N A N D I M P R O V E M E N T P L A N ISSUE FOR PERMIT AND BID 2024-09-13 NORTH NORTH DEMOLITION PLAN C1.0 GENERAL NOTESSURVEYORS NOTES NOTE:LEGEND DEMOLITION/ PROTECT-IN-PLACE NOTES · · · · · DEMOLITION/ PROTECT-IN-PLACE NOTES C1.0 PLAN CHECK #2 2024/10/28 EXISTING BUILDING SU N S E T B L V D THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED ARCADIA, CA 91007 TITLE BMO CLIENT/PROJECT 1045 W. HUNTINGTON DRIVE, CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE AS NOTED Sheet DRAWING NO. PERMIT/SEAL STANTEC 224 SOUTH MICHIGAN AVE, SUITE 1400 CHICAGO, IL 60604 TEL:+1.312.554.1400• www.stantec.com KIMLEY-HORN 3801 UNIVERSITY AVE, STE 300 RIVERSIDE, CA 92501 Tel: +1.951.543.9868 CONSULTANT K: \ R I V _ L D E V \ B M O \ 0 9 4 6 1 5 3 6 6 - A R C A D I A \ C A D \ P L A N S H E E T S \ B M O A R C A D I A DE M O L I T I O N A N D I M P R O V E M E N T P L A N ISSUE FOR PERMIT AND BID 2024-09-13 NORTH NORTH IMPROVEMENT PLAN C2.0 LEGEND CONSTRUCTION NOTES ABBREVIATIONS GENERAL NOTESSURVEYORS NOTES NOTE: · · · · · CONSTRUCTION NOTES C2.0 PLAN CHECK #2 2024/10/28 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED ARCADIA, CA 91007 TITLE BMO CLIENT/PROJECT 1045 W. HUNTINGTON DRIVE, CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE AS NOTED Sheet DRAWING NO. PERMIT/SEAL STANTEC 224 SOUTH MICHIGAN AVE, SUITE 1400 CHICAGO, IL 60604 TEL:+1.312.554.1400• www.stantec.com KIMLEY-HORN 3801 UNIVERSITY AVE, STE 300 RIVERSIDE, CA 92501 Tel: +1.951.543.9868 CONSULTANT K: \ R I V _ L D E V \ B M O \ 0 9 4 6 1 5 3 6 6 - A R C A D I A \ C A D \ P L A N S H E E T S \ B M O A R C A D I A DE M O L I T I O N A N D I M P R O V E M E N T P L A N ISSUE FOR PERMIT AND BID 2024-09-13 ≥ ACCESSIBLE PARKING STRIPING 10CONCRETE CURB 3DETECTABLE WARNINGS SIGN BASE DETAIL 2 ACCESSIBLE RAMP DETAIL5PRECAST CONCRETE WHEEL STOP 4ACCESSIBLE PARKING STALL SIGN THICKENED EDGE 7 9 8GRAVEL BERM (SE-6) ACCESSIBLEVAN PARKING RESERVED FINE $250MINIMUM CONSTRUCTION AND CONTROL JOINT 11 0" CONCRETE CURB 1 6 STANDARD 90° PARKING STALL STRIPING 12 PAVEMENT GRIND AND OVERLAY DETAIL 13 CONSTRUCTION DETAILS C3.0 C3.0 PLAN CHECK #2 2024/10/28 42 " 44 " 44 " 40" GFI GF I J GENERAL NOTES -DEMOLITION PLAN 1. DEMOLITION DRAWINGS REPRESENT EXISTING CONSTRUCTION SYSTEMS AND ASSEMBLIES AND HAVE BEEN COMPILED FROM BEST AVAILABLE INFORMATION. DEMOLITION DRAWINGS ARE NOT INTENDED TO LIMIT SCOPE OF WORK. DRAWINGS DO NOT ILLUSTRATE, IN DETAIL, ALL SYSTEMS AND / OR UNSEEN CONDITIONS WITHIN WALLS, CEILINGS AND FLOORS THROUGHOUT AREA OF WORK. DEMOLITION DRAWINGS ARE OF GENERAL NATURE ONLY DESCRIBING SCOPE OF DEMOLITION WORK. GC TO INSPECT SITE WITH SUBCONTRACTORS AS REQUIRED TO DOCUMENT EXISTING CONDITIONS AND TO SUBMIT ALL DEMOLITION SCOPE QUESTIONS PRIOR TO BIDDING (NO EXCLUSIONS ACCEPTED). 2. PRIOR TO CARRYING OUT DEMOLITION WORK ON PARTITIONS INDICATED TO BE REMOVED, EXISTING FRAMING TO BE EXPOSED FOR ARCHITECT AND ENGINEER'S REVIEW. LOCATIONS OF NEW OPENINGS ARE SHOWN ON DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONCERNS PRIOR TO DEMOLITION. GC TO PROVIDE TEMPORARY AND/OR PERMANENT SUPPORT AS NECESSARY TO MAINTAIN INTEGRITY OF EXISTING STRUCTURES ADJACENT TO AREA OF WORK. 3. GC TO DISCONNECT OR TERMINATE ALL MECHANICAL, ELECTRICAL AND PLUMBING SERVICES TO ALL AREAS WHERE WORK IS TO BE REMOVED OR RELOCATED. SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS FOR DEMOLITION OF ELECTRICAL, HVAC, PLUMBING, TELE / DATA, AND OTHER ITEMS. GC TO COORDINATE DEMOLITION WITH ALL TRADES. 4. GC TO TRACE, PROTECT, AND MAINTAIN ANY EXISTING TELE / DATA, SECURITY CABLES, ETC. FOR DURATION OF CONSTRUCTION THAT MAY SERVE OUTSIDE SCOPE OF WORK. 5. GC TO MAINTAIN CODE COMPLIANT EGRESS PATH, TEMPORARY LIGHTING, AND FIRE PROTECTION THROUGHOUT AREA OF WORK DURING CONSRUCTION. PROVIDE PHASING PLAN TO ARCHITECT, BUILDING MANAGEMENT, AND PROJECT MANAGER FOR REVIEW. 6. GC TO REMOVE ALL DEMOLITION DEBRIS DAILY, INCLUDING DEBRIS GENERATED BY SUBCONTRACTORS. AFTER COMPLETION OF DEMOLITION WORK ALL AREAS ARE TO BE LEFT "BROOM CLEAN." DEBRIS RESULTING FROM DEMOLITION TO BE DISPOSED OF PER APPLICABLE LOCAL LAWS; INCLUDING ALL RECYCLING REQUIREMENTS SET FORTH BY THE AUTHORITY HAVING JURISDICTION, BUILDING MANAGEMENT, AND/OR CLIENT. COORDINATE WITH PROJECT MANAGER REGARDING SALVAGING OF ANY EXISTING FURNITURE, FIXTURES, EQUIPMENT, ETC. 7. EXISTING COLUMN ENCLOSURES AND EXTERIOR WALL FURRING TO REMAIN, TYP. UNO. 8. ALL EXISTING FINISHES, TRIM, FIXTURES, APPLIANCES, AND EQUIPMENT TO REMAIN SHALL BE PROTECTED IN PLACE DURING DEMOLITION AND CONSTRUCTION. DAMAGE TO EXISTING ITEMS OR SURFACES THAT REMAIN TO BE REFINISHED, REPAIRED, OR REPLACED BY GC TO THE SATISFACTION OF PROJECT MANAGER, BUILDING MANAGEMENT, AND ARCHITECT AT NO ADDITIONAL COST. 9. ALL EXISTING DOORS, FRAMES, SIDELIGHTS, HARDWARE, AND EXISTING SIGNAGE TO BE REMOVED WILL REMAIN PROPERTY OF OWNER AND ARE TO BE SALVAGED FOR POSSIBLE REUSE. GC TO CONFIRM ALL REUSABLE ITEMS WITH ARCHITECT AND PROJECT MANAGER. ITEMS INSPECTED AND REJECTED FOR REUSE TO BE DISPOSED OF BY GC AT GC'S EXPENSE. 10. ALL BUILDING STANDARD CONVECTORS TO BE PROTECTED AND SEALED DURING DEMOLITION, TYP. UNO. GC TO INSTALL TEMPORARY FILTER(S) ON ALL RETURN AIR DUCT SOURCES PRIOR TO COMMENCEMENT OF DEMOLITION. COORDINATE WITH BUILDING ENGINEER FOR LOCATION(S). 11. ALL EXISTING LIFE SAFETY DEVICES TO REMAIN OR BE RELOCATED AS NEEDED TO COORDINATE WITH NEW PROPOSED LAYOUT. SEE SHEET G-100 FOR DEFFERED SUBMITTALS AND SHEET G-101 FOR TYP. DEVICE MOUNTING HEIGHTS AND LOCATIONS. 12. REMOVE ALL EXISTING CONSTRUCTION AS INDICATED ON THESE PLANS INCLUDING PARTITIONS, DOORS, FRAMES, AND ALL HANGING CLIPS, STRAPS, HANGERS ETC. REMOVE EXISTING PARTITIONS IN THEIR ENTIRETY FROM SLAB TO STRUCTURE ABOVE. REMOVAL OF PARTITION REQUIRES THAT ITEMS SUCH AS CONDUIT, OUTLETS, RAILINGS, PIPING, PLUMBING, AND FIXTURES BE REMOVED AND REROUTED (SEE MEP DRAWINGS). WHERE PORTIONS OF EXISTING PARTITIONS ARE TO REMAIN, PROVIDE CLEAN STRAIGHT SAW CUT FINISHED ENDS AND OPENINGS. 13. REMOVE ALL EXISTING WALL FINISHES, WALL BASE, AND FLOOR FINISHES, TYP. UNO. PATCH AND REPAIR TO MAKE READY FOR NEW FINISHES. FLOOR FINISHES AT OPENINGS TO BE REMOVED TO DOOR CENTERLINES FOR A CLEAN TRANSITION BETWEEN NEW AND EXISTING WORK, TYP. UNO. SEE FINISH PLAN SHEET A-102 FOR ADDITIONAL INFORMATION. 14. REMOVE ALL EXISTING UNUSED SWITCHES, OUTLETS, AND DATA PORTS INCLUDING WIRING, CONDUIT, AND J-BOXES BACK TO ORIGINAL SOURCE. POWER/DATA LOCATIONS ARE TO BE REUSED TO RECEIVE NEW DEVICE AND COVER PLATE TO MATCH NEW DEVICES, SEE SHEET A-105 FOR DEVICE COLOR / FINISH INFORMATION. 15. REMOVE EXISTING WINDOW TREATMENTS (INCLUDING FILMS) THROUGHOUT AREA OF WORK, TYP. UNO. 16. REMOVE FINISH FLOORING MATERIAL AND BACKERS IN THEIR ENTIRETY, TYP. UNO. REMOVE EXISTING ADHESIVES AS REQUIRED TO ALLOW PROPER INSTALLATION OF NEW FLOORING, PER MANUFACTURER'S REQUIREMENTS. PLUG OR FILL ALL UNUSED FLOOR CORES WITH SIMILAR MATERIAL TO MATCH EXISTING ADJACENT CONDITIONS. 17. UPON COMPLETION OF DEMOLITION, SURVEY FLOOR SLAB TO DETERMINE EXTENTS OF LEVELING REQUIRED TO ACCOMMODATE NEW DEMOUNTABLE PARTITIONS AND FLOOR FINISHES. CONFIRM ALL TOLERANCES WITH MANUFACTURER'S REQUIREMENTS. SEE GENERAL NOTES SHEET G-102 FOR ADDITIONAL INFORMATION AND FLOOR LEVELING COMPOUND SPECIFICATIONS. 18. GC TO COORDINATE WITH MOOD VENDOR FOR INSTALLATION OF NEW OR RECONFIGURATION OF EXISTING MUSIC SYSTEM. GC TO TEMPORARILY SUSPEND, BAG, AND PROTECT ANY EXISTING SPEAKERS, SWITCHES, AND OTHER SYSTEM COMPONENTS DURING DEMOLITION AND CONSTRUCTION. MOOD VENDOR TO EVALUATE EXISTING SYSTEM AND MAKE ANY NECESSARY UPGRADES, COORDINATE WITH PROJECT MANAGER. EXISTING WALL OR CONSTRUCTION TO REMAIN EXISTING ITEM TO BE REMOVED LEGEND -DEMOLITION PLAN AREA NOT IN CONTRACT (N.I.C.) #KEYNOTE KEYNOTES -DEMOLITION PLAN 10 REMOVE EXISTING MAN TRAP AND EMERGENCY EXIT. PRESERVE EXISTING STOREFRONT PER NEW PLANS. 12 REMOVE EXISTING SERVER RACKS, LOW VOLTAGE CABLING AND POWER BACK TO ORIGINAL SOURCE. COORDINATE WITH BMO I.T. FOR EQUIPMENT REMOVAL. 13 BMO VENDOR TO REMOVE EXISTING SAFE DEPOSIT BOXES. GC TO PATCH AND REPAIR AREA AS NEEDED. 6 REMOVE ALL EXISTING FLOOR FINISHES THROUGHOUT BRANCH, UNLESS NOTED OTHERWISE. 15 EXISTING 6" ATM CURB TO REMAIN. GC TO COORDINATE NEED PER NEW ATM REQUIREMENTS. 14 REMOVE EXISTING MOP HOLDER AND SALVAGE FOR REUSE, IF POSSIBLE. REPLACE WITH NEW IF EXISTING CAN'T BE REINSTALLED. 2 REMOVE CHECK WRITING COUNTER AND REPAIR SLAB AS REQUIRED. 3 REMOVE AND RELOCATE EXISTING LIGHTING CONTROLS. 7 REMOVE TV SUPPORT, POWER AND DATA. 8 REMOVE AND REPLACE ALL EXISTING PLUMBING FIXTURES, ACCESSORIES AND INTERIOR FINISHES, UNO. SEE FINISH AND EQUIPMENT PLANS FOR MORE DETAILS. 9 REMOVE AND REPLACE DOOR HARDWARE ON EXISTING STOREFRONT DOORS PER DOOR SCHEDULE. 5 REMOVE EXISTING MILLWORK AND PLUMBING. REMOVE REFRIGERATOR WATER SUPPLY 4 REMOVE ALL EXISTING FURNITURE, FIXTURES, EQUIPMENT, AND MILLWORK THROUGHOUT BRANCH UNLESS NOTED OTHERWISE. COORDINATE WITH CLIENT PROJECT MANAGER FOR ANY ITEMS TO BE SALVAGED OR REUSED. 1 REMOVE COLUMN WOOD VEENER, PATCH AND REPAIR FOR REPAINTING. 11 EXISTING 4" WALL CLEAN OUT. PROTECT IN PLACE. EXISTING ITEM TO BE REMOVED 16 ROLLING FILE STORAGE AND TRACK SYSTEM TO BE REMOVED, REPAIR SLAB AS NEEDED. 17 REMOVE AND RELOCATE EXISTING FIRE EXTINGUISHERS AND CABINET. PATCH AND REPAIR WALL AS REQUIRED GC TO VERIFY IF EXISTING CABINETS AND FIRE EXTINGUISHERS CAN BE SAVED AND REUSED. 18 EXISTING ROUGH OPENING FOR THRU-WALL ATM AND NIGHT DEPOSIT TO REMAIN. GC TO REMOVE EXISTING PLYWOOD AND PROVIDE ACTUAL ROUGH DIMENSIONS TO ARCHITECT. 19 EXISTING ELECTRICAL PANELS TO REMAIN. 20 EXISTING VAULT DOOR AND THRESHOLD TO REMAIN. 21 EXISTING SINK AND FAUCET TO REMAIN, REMOVE AND REINSTALL AS NEEDED. 22 SAWCUT AND REMOVE EXISTING SLAB AS REQUIRED FOR NEW UNDER-SLAB ELECTRICAL. SEE ELECTRICAL DRAWINGS. PATCH SLAB TO MATCH EXISTING. 23 GC TO LOCATE SEWER LINE, SAWCUT AND REMOVE EXISTING SLAB AS REQUIRED FOR NEW SANITARY PIPING. SEE PLUMBING DRAWINGS. 24 EXISTING FIRE ALARM SECURITY PANEL TO BE REMOVED AND RELOCATED. PATCH AS NEEDED. 25 GC TO REMOVE ALL EXISTING FLOOR OUTLETS AND PATCH SLAB TO MATCH EXISTING. 26 SAWCUT AND REMOVE EXISTING SLAB AS REQUIRED FOR NEW PARTIAL HEIGHT PARTITION; REFER TO DETAILS 1/A-500. 1 1 2 5 7 8 8 8 10 3 13 14 6 66 15 11 6 66 6 6 6 16 10 6 12 17 4 9 6 4 4 4 17 4 17 44 4 4 18 18 19 20 21 BUILDING LOBBY (NIC) ELEVATOR (NIC) ELECTRICAL ROOM (NIC) CORRIDOR (NIC) 22 22 22 23 24 25 23 2'- 2 " V I F 26 26 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 DEMOLITION FLOOR PLAN BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 AD-100 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 1/4" = 1'-0"DEMOLITION FLOOR PLAN 1 1 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 LL 10/28/2024 GENERAL NOTES -DEMOLITION REFLECTED CEILING PLAN LEGEND -DEMOLITION REFLECTED CEILING PLAN KEYNOTES -DEMOLITION REFLECTED CEILING PLAN 1 REMOVE EXISTING CEILING GRID, SUSPENSION SYSTEM, LIGHTING, AND CEILING DEVICES. REMOVE, STORE, AND REINSTALL EXISTING MECHANICAL DIFFUSERS PER NEW LAYOUT. EXISTING DUCTWORK TO REMAIN AND TO BE ADJUSTED PER MEP DRAWINGS. 1. DEMOLITION DRAWINGS REPRESENT EXISTING CONSTRUCTION SYSTEMS AND ASSEMBLIES AND HAVE BEEN COMPILED FROM BEST AVAILABLE INFORMATION. DEMOLITION DRAWINGS ARE NOT INTENDED TO LIMIT SCOPE OF WORK. DRAWINGS DO NOT ILLUSTRATE, IN DETAIL, ALL SYSTEMS AND / OR UNSEEN CONDITIONS WITHIN WALLS, CEILINGS AND FLOORS THROUGHOUT AREA OF WORK. DEMOLITION DRAWINGS ARE OF GENERAL NATURE ONLY DESCRIBING SCOPE OF DEMOLITION WORK. GC TO INSPECT SITE WITH SUBCONTRACTORS AS REQUIRED TO DOCUMENT EXISTING CONDITIONS AND TO SUBMIT ALL DEMOLITION SCOPE QUESTIONS PRIOR TO BIDDING (NO EXCLUSIONS ACCEPTED). 2. PRIOR TO CARRYING OUT DEMOLITION WORK ON PARTITIONS INDICATED TO BE REMOVED, EXISTING FRAMING TO BE EXPOSED FOR ARCHITECT AND ENGINEER'S REVIEW. LOCATIONS OF NEW OPENINGS ARE SHOWN ON DRAWINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES OR CONCERNS PRIOR TO DEMOLITION. GC TO PROVIDE TEMPORARY AND/OR PERMANENT SUPPORT AS NECESSARY TO MAINTAIN INTEGRITY OF EXISTING STRUCTURES ADJACENT TO AREA OF WORK. 3. GC TO DISCONNECT OR TERMINATE ALL MECHANICAL, ELECTRICAL AND PLUMBING SERVICES TO ALL AREAS WHERE WORK IS TO BE REMOVED OR RELOCATED. SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS FOR DEMOLITION OF ELECTRICAL, HVAC, PLUMBING, TELE / DATA, AND OTHER ITEMS. GC TO COORDINATE DEMOLITION WITH ALL TRADES. 4. GC TO TRACE, PROTECT, AND MAINTAIN ANY EXISTING TELE / DATA, SECURITY CABLES, ETC. FOR DURATION OF CONSTRUCTION THAT MAY SERVE OUTSIDE SCOPE OF WORK. 5. GC TO MAINTAIN CODE COMPLIANT EGRESS PATH, TEMPORARY LIGHTING, AND FIRE PROTECTION THROUGHOUT AREA OF WORK DURING CONSRUCTION. PROVIDE PHASING PLAN TO ARCHITECT, BUILDING MANAGEMENT, AND PROJECT MANAGER FOR REVIEW. 6. GC TO REMOVE ALL DEMOLITION DEBRIS DAILY, INCLUDING DEBRIS GENERATED BY SUBCONTRACTORS. AFTER COMPLETION OF DEMOLITION WORK ALL AREAS ARE TO BE LEFT "BROOM CLEAN." DEBRIS RESULTING FROM DEMOLITION TO BE DISPOSED OF PER APPLICABLE LOCAL LAWS; INCLUDING ALL RECYCLING REQUIREMENTS SET FORTH BY THE AUTHORITY HAVING JURISDICTION, BUILDING MANAGEMENT, AND/OR CLIENT. COORDINATE WITH PROJECT MANAGER REGARDING SALVAGING OF ANY EXISTING FURNITURE, FIXTURES, EQUIPMENT, ETC. 7. EXISTING COLUMN ENCLOSURES AND EXTERIOR WALL FURRING TO REMAIN, TYP. UNO. 8. ALL EXISTING FINISHES, TRIM, FIXTURES, APPLIANCES, AND EQUIPMENT TO REMAIN SHALL BE PROTECTED IN PLACE DURING DEMOLITION AND CONSTRUCTION. DAMAGE TO EXISTING ITEMS OR SURFACES THAT REMAIN TO BE REFINISHED, REPAIRED, OR REPLACED BY GC TO THE SATISFACTION OF PROJECT MANAGER, BUILDING MANAGEMENT, AND ARCHITECT AT NO ADDITIONAL COST. 9. ALL EXISTING DOORS, FRAMES, SIDELIGHTS, HARDWARE, AND EXISTING SIGNAGE TO BE REMOVED WILL REMAIN PROPERTY OF OWNER AND ARE TO BE SALVAGED FOR POSSIBLE REUSE. GC TO CONFIRM ALL REUSABLE ITEMS WITH ARCHITECT AND PROJECT MANAGER. ITEMS INSPECTED AND REJECTED FOR REUSE TO BE DISPOSED OF BY GC AT GC'S EXPENSE. 10. ALL BUILDING STANDARD CONVECTORS TO BE PROTECTED AND SEALED DURING DEMOLITION, TYP. UNO. GC TO INSTALL TEMPORARY FILTER(S) ON ALL RETURN AIR DUCT SOURCES PRIOR TO COMMENCEMENT OF DEMOLITION. COORDINATE WITH BUILDING ENGINEER FOR LOCATION(S). 11. ALL EXISTING LIFE SAFETY DEVICES TO REMAIN OR BE RELOCATED AS NEEDED TO COORDINATE WITH NEW PROPOSED LAYOUT. SEE SHEET G-100 FOR DEFFERED SUBMITTALS AND SHEET G-101 FOR TYP. DEVICE MOUNTING HEIGHTS AND LOCATIONS. 12. REMOVE ALL EXISTING CONSTRUCTION AS INDICATED ON THESE PLANS INCLUDING PARTITIONS, DOORS, FRAMES, AND ALL HANGING CLIPS, STRAPS, HANGERS ETC. REMOVE EXISTING PARTITIONS IN THEIR ENTIRETY FROM SLAB TO STRUCTURE ABOVE. REMOVAL OF PARTITION REQUIRES THAT ITEMS SUCH AS CONDUIT, OUTLETS, RAILINGS, PIPING, PLUMBING, AND FIXTURES BE REMOVED AND REROUTED (SEE MEP DRAWINGS). WHERE PORTIONS OF EXISTING PARTITIONS ARE TO REMAIN, PROVIDE CLEAN STRAIGHT SAW CUT FINISHED ENDS AND OPENINGS. 13. REMOVE ALL EXISTING WALL FINISHES, WALL BASE, AND FLOOR FINISHES, TYP. UNO. PATCH AND REPAIR TO MAKE READY FOR NEW FINISHES. FLOOR FINISHES AT OPENINGS TO BE REMOVED TO DOOR CENTERLINES FOR A CLEAN TRANSITION BETWEEN NEW AND EXISTING WORK, TYP. UNO. SEE FINISH PLAN SHEET A-102 FOR ADDITIONAL INFORMATION. 14. REMOVE ALL EXISTING UNUSED SWITCHES, OUTLETS, AND DATA PORTS INCLUDING WIRING, CONDUIT, AND J-BOXES BACK TO ORIGINAL SOURCE. POWER/DATA LOCATIONS ARE TO BE REUSED TO RECEIVE NEW DEVICE AND COVER PLATE TO MATCH NEW DEVICES, SEE SHEET A-105 FOR DEVICE COLOR / FINISH INFORMATION. 15. REMOVE EXISTING WINDOW TREATMENTS (INCLUDING FILMS) THROUGHOUT AREA OF WORK, TYP. UNO. 16. REMOVE FINISH FLOORING MATERIAL AND BACKERS IN THEIR ENTIRETY, TYP. UNO. REMOVE EXISTING ADHESIVES AS REQUIRED TO ALLOW PROPER INSTALLATION OF NEW FLOORING, PER MANUFACTURER'S REQUIREMENTS. PLUG OR FILL ALL UNUSED FLOOR CORES WITH SIMILAR MATERIAL TO MATCH EXISTING ADJACENT CONDITIONS. 17. UPON COMPLETION OF DEMOLITION, SURVEY FLOOR SLAB TO DETERMINE EXTENTS OF LEVELING REQUIRED TO ACCOMMODATE NEW DEMOUNTABLE PARTITIONS AND FLOOR FINISHES. CONFIRM ALL TOLERANCES WITH MANUFACTURER'S REQUIREMENTS. SEE GENERAL NOTES SHEET G-102 FOR ADDITIONAL INFORMATION AND FLOOR LEVELING COMPOUND SPECIFICATIONS. 18. GC TO COORDINATE WITH MOOD VENDOR FOR INSTALLATION OF NEW OR RECONFIGURATION OF EXISTING MUSIC SYSTEM. GC TO TEMPORARILY SUSPEND, BAG, AND PROTECT ANY EXISTING SPEAKERS, SWITCHES, AND OTHER SYSTEM COMPONENTS DURING DEMOLITION AND CONSTRUCTION. MOOD VENDOR TO EVALUATE EXISTING SYSTEM AND MAKE ANY NECESSARY UPGRADES, COORDINATE WITH PROJECT MANAGER. EXISTING WALL OR CONSTRUCTION TO REMAIN EXISTING ITEM TO BE REMOVED AREA NOT IN CONTRACT (N.I.C.) #KEYNOTE EXISTING ITEM TO BE REMOVED 2 EXISTING CEILING TO REMAIN, REMOVE AND REPLACE EXISTING LIGHTING AND DIFFUSERS. PATCH AND PREP FOR PAINT. 3 REMOVE EXISTING GYP. CEILING, LIGHTING, AND CEILING DEVICES. 4 REMOVE AND RE-ROUTE SPRINKLER HEAD AS REQUIRED. SEE SHOP DRAWING BY SPRINKLER SUBCONTRACTOR. 5 REMOVE RESTROOM VANITY LIGHT FIXTURE, PATCH AND REPAIR WALL FOR NEW FINISHES. 6 EXISTING GYP. CEILING / SOFFIT TO REMAIN. PROTECT IN PLACE. 7 EXISTING LIGHT FIXTURE TO REMAIN. 8 EXISTING LIGHT FIXTURES TO BE REMOVED. 9 EXISTING ELEC PANEL, REFER TO ELECTRICAL DRAWINGS. 4 1 1 3 3 1 1 1 5 1 1 1 1 1 1 2 2 6 66 6 GYP 8' - 3" ACT 10' - 0" EXIST. 10' - 4" ACT 10' - 7" ACT 9' - 10" ACT 9' - 0" ACT 9' - 0" EXIST. 8' - 11" EXIST. 8' - 11" EXIST. 10' - 3" EXIST. 10' - 3" GYP 8' - 0" EXIST. 9' - 7" ACT 9' - 2" ACT 8' - 0" ACT 8' - 0" ACT 9' - 1" ACT 10' - 0" ACT 9' - 0" BUILDING LOBBY (NIC) ELEVATOR (NIC) ELECTRICAL ROOM (NIC) CORRIDOR (NIC) 78 9 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 DEMOLITION REFLECTED CEILING PLAN BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 AD-101 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 1/4" = 1'-0"DEMOLITION REFLECTED CEILING PLAN 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 A-400 1 A-200 1 A-2016 A-201 1 114 UNIVERSAL RR 115 JANITOR CLOSET 113 RESTROOM A-201 3 4 A-202 4 A-202 3 A-202 1 A-203 1 M107-02 M107-01 M104-01 M122-01 M121-01 M121-02 M121-03 M121-04 M119-01 M116-01 105 ATM / LAN ROOM 104 WORK ROOM 106 CMR.3 107 RRB 108 CMR.4 102 LOUNGE.1 101 BANKING HALL 103 LOUNGE.2 109 MEETING ROOM 110 STAFF ROOM 112 CORRIDOR 117 EXISTING SD VAULT 119 COUPON BOOTH 120 BM 122 EMPLOYEE ENCLAVE 124 CMR.1 123 CMR.2 100 COMMON VESTIBULE 121 AB 116 CORRIDOR M110-01 M114-01 106 105A 101A 100 124 123 121 120 119 108 109 105B 101B ELECTRICAL ROOM ELEVATOR M121-06 M121-05 A-401 1 A-202 A-203 9 A-202 12 13ALIGNALIGN AL I G N 1 2 2 3 3 2 10 11 2 A-201 5 111 M111-01 8 4 4 9 3 4 5 4 4 4 4 4 6 A-20214 UP 115 114 113 110 117 4 4 111 COAT CLOSET 2ND LEVEL EGRESS STAIRS 122 104 10 11 12 MIN. 1' - 0 " 13 5'- 5 1 / 4 " 13 ' - 4 " 8'-6 1/2"5"6'-1 1/2" HOLD 7'-6" 2'-6" A-2033 3'-0"10'-5" 3'-0"9'-4 1/4" ALIGN ALIGN AL I G N 5"6'-0"6'-8 1/4"9" 3'-0"10'-5 1/4" 5" 10 ' - 6 1 / 4 " 5" 5'-0 3/4" 1'- 6 " 1'- 4 " 10 ' - 5 3 / 4 " 4'- 6 " 6" 2'- 5 1 / 4 " 4'-0 1/4" 4'-10"10" 5' - 7 1 / 4 " 3' - 4 3 / 4 " 5'- 7 1 / 4 " 3'- 0 " AL I G N AL I G N 9'-6 1/4"3'-0" 9'-5 1/4" 2'- 1 " 29 ' - 9 1 / 4 " 1'- 1 1 " 10"4'-10" 12'-9 1/4"+/- 5"2'-1" 5'- 3 1 / 2 " 16'-0" 4'- 2 1 / 2 " 1'-8" AL I G N 1'- 0 1 / 4 " ALIGN 2'-1 1/4" ALIGN 1'-6"1'-4 1/4" A-500 2 A-500 2 A-500 2 A-500 2 A-500 2 A-500 3 A-500 3 AL I G N A-500 7 3'- 1 " A-500 7 SIM. A-500 7 SIM. PF2PF2 PF2 PF2PF2 PF2 P1 PF2 P1 PF2 PF2 PF2 P2P2 P1 P2 P2 P1 PF2 PF2 P2 P1 P2 P2 P1 PP1PP1PP1 PF2 DP2 DP2 DP2 DP2DP2 DP2DP2 DP2DP2 DP2 DP2DP2 SF2 PF2 A-2034 11 ' - 7 3 / 4 " 5" 12 ' - 3 1 / 4 " 5" 8' - 5 3 / 4 " 5" 5" 9'- 1 0 3 / 4 " 5" PP3 PP3 3" 9' - 0 " 2 1/2" 8'-0" 1'-0" A 14 HOLD 2'-2" 15 5 A-203 6 V.I.F. 1'-7 1/2"6'-0"4'-7 1/2" P1 PP3 7 DP2 3'-0"12'-8" HP1 HP1 PF1 P1PV A-500 2 SIM. SIM. 2 M113-01 SIM. A-203 7 A-203 8 16 5'-0 3/4" 9 M122-02 3 17 TYP. 1 1 EXISTING WALL OR CONSTRUCTION TO REMAIN NEW WALL OR CONSTRUCTION, SEE PARTITION TYPE SCHEDULE NEW DEMOUNTABLE PARTITION SYSTEM BY FURNITURE VENDOR, SEE PARTITION TYPE SCHEDULE ### DOOR TAG, SEE DOOR SCHEDULE LEGEND -PARTITION PLAN MILLWORK TAG, SEE MILLWORK SCHEDULE GENERAL NOTES -PARTITION PLAN AREA NOT IN CONTRACT (N.I.C.) NAME ###ROOM NAME AND NUMBER #KEYNOTE 1. DO NOT SCALE FROM THESE DRAWINGS. NOTIFY ARCHITECT REGARDING OF ANY DISCREPANCIES OR MISSING INFORMATION PRIOR TO CONSTRUCTION. 2. LARGE SCALE DRAWINGS HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. 3. GC TO VERIFY ALL EXISTING CONDITIONS IN FIELD. 4. ALIGN NEW PARTITIONS WITH EXISTING PARTITIONS TO REMAIN. AT MULLIONS, ALIGN CENTERLINE OF WALL WITH CENTERLINE OF MULLION, SEE DETAILS SHEET A-501. ALL PARTITIONS ARE DIMENSIONED FROM FINISHED FACE TO FINISHED FACE, TYP. UNO. 5. GC TO FIELD VERIFY ALL DIMENSIONS FOR LOCATIONS OF NEW PARTITIONS & DOOR OPENINGS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. GC TO OBTAIN ARCHITECT’S REVIEW AND APPROVAL OF PARTITION LAYOUT PRIOR TO INSTALLATION OF TRACK AND STUD FRAMING. 6. INFILL PARTITIONS TO MATCH ADJACENT PARTITIONS IN BOTH CONSTRUCTION AND THICKNESS. 7. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING CORNER BEAD AND PROVIDE SMOOTH FINISH AT INTERSECTIONS. 8. WHERE NEW PARTITION OR MILLWORK INTERSECTS WINDOW AND/OR CONVECTOR AT PERIMETER, APPLY SOUND TRANSFER INSULATION AND ENSURE THAT ALL OPENINGS HAVE BEEN SEALED BETWEEN ADJOINING SPACES TP PREVENT SOUND TRANSMISSION. SEE DETAILS SHEET A-501. 9. PARTITIONS OVER DOORS TO BE CONTINUOUS AND IN SAME PLANE AS ADJACENT WALLS WHERE DRYWALL CONTINUES TO STRUCTURE ABOVE, OR ABOVE CEILING, TYP. UNO. 10. PATCH, LAMINATE, OR FURR EXISTING COLUMNS & WALLS AS REQUIRED THROUGHOUT ENTIRE SPACE TO ACCEPT NEW FINISHES, RECEIVE NEW ELECTRICAL / DATA / PLUMBING, RECEIVE BLOCKING WHERE REQUIRED FOR WALL-MOUNTED ITEMS, AND MEET DESIGN INTENT, TYP. UNO. EXTEND FURRING AS NOTED IN PARTITION TYPE DETAILS, SHEET A-500. 11. PATCH AND REPLACE ANY MISSING OR DAMAGED FIREPROOFING WHERE REQUIRED. 12. PROVIDE WATER RESISTANT GREEN BOARD AT HIGH MOISTURE AND/OR WET AREAS NOT FINISHED IN TILE (I.E. SINKS, RESTROOM FIXTURES), TYP. UNO. 13. PROVIDE TILE BACKER BOARD AS REQUIRED AT ALL TILE / STONE WET AREA APPLICATIONS (I.E. SINKS, TOILETS, ETC.) 14. GC TO CAULK AND SEAL ALL PENETRATIONS THROUGH EXTERIOR WALLS TO MINIMIZE ENERGY LOSS. 15. GC TO VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY SUBCONTRACTORS OR FURNITURE VENDOR. 16. GC TO COORDINATE BLOCKING REQUIREMENTS AND LOCATIONS WITH ELEVATIONS AND DETAILS AND PROVIDE CONCEALED SUPPORT IN PARTITIONS FOR ALL WALL-HUNG ITEMS. SEE DETAILS SHEET A-500. 17. ALL BLOCKING AND WOOD FURRING TO BE FIRE RETARDANT TREATED. COORDINATE WITH MILLWORK, ELECTRICAL CONTRACTORS, ETC. AS REQUIRED. 18. FIRE EXTINGUISHER CABINET LOCATIONS TO BE DETERMINED BY CODE OFFICIAL. 19. SEE MILLWORK SCHEDULE SHEET A-605 FOR ADDITIONAL INFORMATION. 20. TEKNION ALTOS DEMOUNTABLE PARTITIONS TO BE PROVIDED AND INSTALLED BY BMO VENDOR. GC TO REFER TO SHOP DRAWINGS BY BMO VENDOR. 21. SEE EGRESS PLAN SHEET G-105 FOR ALL REQUIRED EXITING SIGNAGE LOCATIONS. #WALL / PARTITION TYPE, SEE PARTITION TYPE SCHEDULE WINDOW TAG, SEE WINDOW SCHEDULE# ### NEW MILLWORK BY GC KEYNOTES -PARTITION PLAN 1 MOP SINK WITH WATER HEATER ON PLATFORM ABOVE. REFER TO DETAIL 6/A-504 AND PLUMBING DRAWINGS. 2 PROVIDE IN-WALL BLOCKING AS REQUIRED FOR APPLIED WOOD SLATS AND SURFACE-MOUNTED MONITOR, COORDINATE WITH AV DRAWINGS. SEE DETAILS. 3 PROVIDE GROMMET; REFER TO MILLWORK SECTIONS FOR MORE INFORMATION. 4 EXISTING STOREFRONT TO REMAIN. 5 EXISTING DOOR, PROTECT IN PLACE. PROVIDE NEW HARDWARE PER DOOR SCHEDULE. 6 DEMOUNTABLE PARTITION TO BE CENTERED ON ANGLED WALL. 7 PARTIAL HEIGHTED WALL FURRING. SEE ELEVATION FOR HEIGHT. 8 EXISTING THRU-WALL OPENING FOR WALK-UP ATM. GC TO REMOVE PLYWOOD TO REVIEW ATM OPENING DIMENSIONS, AND COORDINATE WITH BMO ATM VENDOR IF EXISTING CONCRETE EQUIPMENT PLINTH SHALL BE REMOVED. 9 EXISTING WALL CLEANOUT TO REMAIN. PROVIDE CHROME COVER PLATE WITH SECURING SCREW TO WALL 10 PROVIDE 3/4" F.T. PLYWOOD 6" A.F.F. TO 8'-6" A.F.F., PAINTED TO MATCH SURROUNDING WALLS AS REQUIRED FOR WALL-MOUNTED EQUIPMENT. COORDINATE WITH TELECOM, AV AND SECURITY DRAWINGS. 11 GC TO LOCATE NEW DOOR TO OPEN AT MIN. 90 DEGREE ANGLE. 12 GC TO FIELD VERIFY DIMENSION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES 13 GC TO RELOCATE FIRE ALARM SECURITY PANEL. 14 NEW LAN ROOM CAGE. REFER TO 4/A-203. GC TO REVIEW HOLD DIMENSIONS AND COMMUNICATE ANY DISCREPANCIES TO ARCHITECT. 15 CAGE LATERAL BRACING BY MANUFACTURER, TYPICAL BOTH SIDES. 16 GC TO REMOVE EXISTING PLYWOOD AND NOTIFY ARCHITECT OF EXISTING NIGHT DEPOSIT ROUGH OPENING DIMENSIONS AND HEIGHT ABOVE FINISH FLOOR. GC TO INCLUDE IN BID REPLACEMENT OF MATCHING PANEL TO ACCOMODATE NEW EQUIPMENT. 17 PROVIDE POSTS AS REQUIRED FOR PARTIAL HEIGHT PARTITIONS. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 2 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 PARTITION PLAN BMO BANK N.A. TENANT IMPROVEMENT SS DRAW 2024/05/31 222702550 1/4" = 1'-0" A-100 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1/4" = 1'-0"PARTITION PLAN 1SCALE TRUE NORTH ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 2 PLAN CHECK #3 SS DR 2024/11/12 2 ALLL 10/28/2024 LEGEND -REFLECTED CEILING PLAN GENERAL NOTES -REFLECTED CEILING PLAN AREA NOT IN CONTRACT (N.I.C.) NAME ###ROOM NAME AND NUMBER GYP. BD. CEILING #KEYNOTE CEILING TYPES - SEE FINISH SCHEDULE FOR SPECIFICATIONS AND PAINT COLORS 1. GC TO COORDINATE ALL TRADES AFFECTED BY HUNG CEILING CONSTRUCTION (HVAC, SPRINKLER, LIGHTING, POWER, ETC). 2. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ALL REQUIRED LOW VOLTAGE CABLING, TERMINATIONS, CONDUITS, PULL BOXES, HOME RUNS, WALL JUNCTION BOXES, PLASTER RINGS, ETC. FOR INSTALLATION OF ALL VOICE / DATA DEVICES, CABLES, SECURITY DEVICES, ETC. GC TO COORDINATE WITH OWNER'S VENDOR FOR REQUIREMENTS. 3. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR SUPPLYING SHOP DRAWINGS FOR SPECIFIED EQUIPMENT FOR APPROVAL TO ARCHITECT ON A TIMELY BASIS. 4. CENTER CEILING GRID AND TILE IN ENCLOSED ROOMS. 5. CENTER ALL DEVICES WITHIN CEILING TILE -LIGHT FIXTURES, FIRE ALARM DEVICES, MOTION SENSORS, SPRINKLER HEADS (WHERE APPLICABLE), HVAC SUPPLY / RETURN GRILLES, AND ANY OTHER DEVICES -TYP. UNO. 6. ALL ACCESS PANELS AT GYP. BD. CEILINGS TO BE MUD-IN, FRAMELESS WITH ROUNDED CORNERS. ACCESS PANELS LOCATIONS TO BE APPROVED BY ARCHITECT. ACCESS PANELS AT CEILING TO BE CENTERED AND ALIGNED WITH ADJACENT FIXTURES AND DEVICES, UNO. SEE GENERAL NOTES SHEET G-102 FOR APPROVED ACCESS PANEL SPECIFICATIONS. 7. PROVIDE LEVEL 5 FINISH AT ALL GYP. BD. CEILINGS ABOVE LIGHT COVES. 8. ALL SPRINKLER HEADS ARE TO BE RECESSED. 9. ALL SPRINKLER HEADS WITHIN WHITE ACT OR WHITE PAINTED GYP. BD. CEILINGS TO BE WHITE. ALL SPRINKLER HEADS WITHIN MILLWORK TO BE STAINLESS STEEL FINISH. COORDINATE WITH ARCHITECT FOR SPRINKLER HEAD FINISH IN ANY CEILING NOT NOTED ABOVE. 10. ALL MECHANICAL DUCTS, SPRINKLER PIPES AND ELECTRICAL CONDUITS TO BE PAINTED WHEN LOCATED IN OPEN CEILINGS, TYP. UNO. SEE KEYNOTES AND FINISH SCHEDULE FOR PAINT COLORS. 11. GC TO CLEAN / WIPE DUST FROM TOPS OF EXPOSED MECHANICAL DUCTS AND LIGHT FIXTURES PRIOR TO FURNITURE INSTALLATION. 12. ALL NEW AND EXISTING GYP BOARD CEILINGS TO BE PAINTED PT-2. SEE FINISH SCHEDULE SHEET A-602 FOR ALL CEILING FINISHES, SPECIFICATIONS, AND PAINT COLORS. 13. REFER TO SHEET A-503 FOR CEILING RELATED DETAILS. LIGHTING FIXURE NOTES: 1. SEE LIGHT FIXTURE SCHEDULE SHEET A-604 AND LIGHTING CONSULTANT DRAWINGS FOR FIXTURE SPECIFICATIONS AND ADDITIONAL INFORMATION. 2. ALL LIGHTING TO BE INSTALLED IN CONFORMANCE WITH ELECTRICAL CODES. NIGHT LIGHTS, EXIT LIGHTS, AND ALARMS TO BE PROVIDED BY GC AS REQUIRED. 3. GC TO LAY OUT LIGHT FIXTURES PRIOR TO INSTALLATION AND CONFIRM ALL SWITCH LOCATIONS, AND OBTAIN ARCHITECT'S APPROVAL IN WRITING PRIOR TO PROCEEDING. 4. FOR LIGHT FIXTURE AND DEVICE LOCATIONS, ARCHITECTURAL DRAWINGS SUPERSEDE MEP DRAWINGS. IN CASE OF MAJOR DISCREPANCIES BETWEEN MEP AND ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT PRIOR TO INSTALLATION. 5. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ENSURING COMPATIBILITY BETWEEN FIXTURE TRIMS AND CEILING GRID. 6. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR LAMPING OF ALL LIGHTING FIXTURES AS SPECIFIED, TYP. UNO. 7. ELECTRICAL AND MILLWORK CONTRACTORS TO COORDINATE HEIGHTS AND LOCATIONS OF ALL LIGHT FIXTURES AND SERVICE CONNECTIONS TO BE INSTALLED IN OR ON MILLWORK. ARCHITECT TO APPROVE FINISHES AND COLORS OF ALL COVER PLATES TO BE INSTALLED IN MILLWORK. GC TO COORDINATE. 8. GC TO COORDINATE WITH ALL TRADES INVOLVED IN INSTALLATION OF SERIES OR RUNS OF STRIP FIXTURES (I.E. ELECTRICAL, DRYWALL, MILLWORK, ETC.) TO ESTABLISH / DETERMINE EXACT DIVISIONS OF FIXTURES, REQUIRED LENGTH OF EACH FIXTURE(S) (ACTUAL NOT NOMINAL), AND QUANTITIES OF FIXTURES FOR THE SERIES OR RUN. HOWEVER, THE DIVISION OF FIXTURES, LENGTH OF FIXTURES, AND QUANTITIES OF FIXTURES MUST FOLLOW THE FOLLOWING GUIDELINES: A. MAX. DISTANCE BETWEEN ADJACENT CONSTRUCTION AND END OF FIXTURE(S) TO BE 6" TYP. B. PROVIDE CONSISTENT AND / OR TYPICAL FIXTURE LENGTHS WITHIN A RUN (I.E. FOR A 20'-0" RUN OF FIXTURES, PROVIDE (4) 5'-0" FIXTURES.) C. IF CONSTRUCTION CONDITIONS AND / OR OVERALL DIMENSIONS FOR THE RUN OF FIXTURES REQUIRES A MIX OF FIXTURE LENGTHS TO ACHIEVE THE REQUIRED TOTAL LENGTH, GROUP TOGETHER FIXTURES OF SIMILAR LENGTHS (I.E. FOR A 23'-0" RUN OF FIXTURES, PROVIDE (2) 4'-0" FIXTURES GROUPED TOGETHER WITH (3) 5'-0" FIXTURES GROUPED TOGETHER.) D. PROVIDE THE LONGEST FIXTURE LENGTHS POSSIBLE TO ACHIEVE OVERALL DIMENSIONS (I.E. FOR A 20'-0" RUN OF FIXTURES PROVIDE (4) 5'-0" FIXTURES VERSUS (10) 2'-0" FIXTURES.) 9. ALL EXIT LIGHTS AND SIGNAGE TO MATCH BASE BUILDING STANDARD, TYP. UNO. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL GASKETS ON INSIDE CEILING PLATES OF RECESSED EXIT LIGHTS TO CONTAIN LIGHT LEAK. 10. ALL LIGHT FIXTURE MOUNTING HEIGHTS INDICATED IN PLANS ARE MEASURED FROM FINISHED FLOOR TO THE BOTTOM OF THE LIGHT FIXTURE. LIGHTING CONTROL NOTES: 1. ALL LIGHTS TO BE CONTROLLED VIA MOTION SENSORS AND OVERRIDE SWITCHES, SEE ENGINEERING DRAWINGS. 2. SEE POWER AND DEVICE PLAN GENERAL NOTES ON SHEET A-105 FOR THE FOLLOWING: A. LIGHT SWITCH AND FACEPLATE INFORMATION INCLUDING DEVICE COLOR AND GANGING DIRECTION B. LIFE SAFETY DEVICE INFORMATION (SEE ENGINEERING DRAWINGS FOR ADDITIONAL INFO) 3. SEE SHEET G-102 FOR TYP. DEVICE HEIGHTS AND MOUNTING LOCATIONS. CEILING DEVICES CEILING TYPE AND HEIGHT ABOVE FINISHED FLOOR, SEE FINISH SCHEDULE FINISH HEIGHT L# LIGHT FIXTURE TAG KEYNOTES -REFLECTED CEILING PLAN 1 PENDANT LIGHT TO BE CENTERED OVER STAFF ROOM TABLE. COORDINATE LOCATION WITH FURNITURE PLACEMENT. 2 PENDANT LIGHT TO BE CENTERED OVER DESK. COORDINATE LOCATION WITH FURNITURE PLACEMENT. 3 PENDANT LIGHT TO BE CENTERED OVER LOUNGE FURNITURE. COORDINATE PENDANT LOCATION WITH FURNITURE PLACEMENT. 4 NEW EXTERIOR WALL PACK. SEE EXTERIOR ELEVATION FOR DETAILS. 5 WALL MOUNTED SPLIT UNIT, SEE MECHANICAL DRAWINGS. 6 EXISTING EXTERIOR AWNING TO REMAIN. SUPPLY GRILLE, SEE MECHANICAL DRAWINGS RETURN GRILLE, SEE MECHANICAL DRAWINGS ACCESS PANEL EXHAUST GRILLE, SEE MECHANICAL DRAWINGS CEILING MOUNTED WIRELESS ACCESS POINT, PROVIDE (2) DATA CABLES. COORDINATE WITH BMO VENDOR AND BMO IT FOR FINAL LOCATIONS AND WIRING REQUIREMENTS.WAP CEILING MOUNTED EXGRESS SIGN INTERNALLY ILLUMINATED S RECESSED CEILING SPEAKERS, SEE VENDOR DRAWINGS 360 DEGREE CAMERA, SEE SECURITY DRAWINGS FIXED CEILING MOUNT CAMERA, SEE SECURITY DRAWINGS C C HEIGHT STRIP CAMERA, SEE SECURITY DRAWINGSHS (N) OS OCCUPANCY SENSOR, SEE ELECTRICAL DRAWINGS PS DAYLIGHT SENSOR, SEE ELECTRICAL DRAWINGS EMERGENCY LIGHT FIXTUREEM1 MOTION DETECTOR CEILING MOUNTED, SEE SECURITY DRAWINGSMD ACOUSTIC TILE CEILING EXISTING GYP. BD. CEILING PAINTED METAL SOFFIT / SHADE POCKET LEGEND -LIGHTING TYPES UNDER-CABINET LED STRIP LIGHT - LENGTHS VARY LC1A PENDANT LIGHTLP1 LC1B LC1C LC1D 6" RECESSED DOWNLIGHTEL1 EXTERIOR LINEAR WALL WASHEREL2 EXTERIOR LINEAR WALL WASHEREL3 24" x 48" RECESSED LED 24" x 24" RECESSED LEDLA2 LA1 LED STRIP LIGHTLC2 4" SQUARE RECESSED DOWNLIGHTLD1 RECESSED LINEAR WALL WASHERLL1 48" LINEAR PENDANTLP2 ACCENT ACOUSTIC PENDANTLP3 ACCENT ACOUSTIC PENDANTLP4 ACCENT ACOUSTIC PENDANTLP5 ACCENT ACOUSTIC PENDANTLP6 ACCENT ACOUSTIC PENDANTLP7 ACCENT CLUSTER PENDANTLP8A ACCENT CLUSTER PENDANTLP8B ACCENT PENDANTLP8C ACCENT PENDANTLP9A LP9B ACCENT PENDANTLP10 ACCENT CLUSTER PENDANTLP11A ACCENT CLUSTER PENDANTLP11B ACCENT CLUSTER PENDANTLP11C SURFACE MOUNTED LINEAR LIGHTLS1 PENDANT MOUNTED LINEAR LIGHTLS2 DECORATIVE WALL SCONCELW1 24" DECORATIVE WALL SCONCELW2 DECORATIVE WALL SCONCELW3LINEAR COVE LIGHTLC3 7 PENDANT LIGHT TO BE CENTERED OVER MEETING ROOM TABLE. COORDINATE LOCATION WITH FURNITURE PLACEMENT. 8 OUTDOOR 360 DEGREE CAMERA MOUNTED ABOVE DOORS. 9 LINEAR LIGHT FIXTURES TO BE JOINED AND CENTERED IN SOFFIT. 10 EXISTING LIGHT FIXTURE TO REMAIN. ELECTRICAL ROOM ELEVATOR GYP. 10' - 3" 105 ATM / LAN ROOM 104 WORK ROOM 106 CMR.3 101 BANKING HALL 107 RRB 108 CMR.4 109 MEETING ROOM 110 STAFF ROOM 112 CORRIDOR 115 JANITOR CLOSET 114 UNIVERSAL RR 116 CORRIDOR 117 EXISTING SD VAULT 119 COUPON BOOTH 120 BM 121 AB 122 EMPLOYEE ENCLAVE 123 CMR.2 124 CMR.1 113 RESTROOM ACT-1 10' - 7" ACT-1 10' - 0" ACT-1 8' - 0" EXIST. 8' - 11" EXIST. 8' - 11" ACT-1 10' - 0" ACT-1 10' - 3" ACT-1 10' - 0" EXIST. 10' - 3" EXIST. 10' - 3" EXIST. 9' -7" ACT-2 9' - 0" ACT-2 9' - 0" LA1 LA1LA1LA1LA1 LD1 LD1 ACT-1 10' - 7" ACT-1 10' - 7" ACT-1 10' - 0" ACT-1 10' - 0" LP2 LD1 LD1 LP2 LD1 LD1 LA1 LA1 LD1 LD1 LD1LD1 LD1LD1 LD1 LD1 LD1 LD1 LD1LD1 LP2 LC1CLC1C LC1C LC1C LC1C LC1C LC1CLC1C LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1LA1LA1LA1 LA1 LA1LA1 LA1 LA1 LA1LA1LA1LA1LA1 LA1 LA1 LA1 LA1 LA1LA1 LA1 LA1 LD1 LP2 LP2 LD1 LD1 EXIST. 10' - 4" 9'-0"A.F.F. 3 4 10 LD1 LD1 LD1 LD1 LD1 2 2 2 2 2 1 5 100 COMMON VESTIBULE WAP LW1 LW1 LW1 LW1 ACT-2 9' - 0" TYP. LP11C LP11A ACT-2 9' - 0" ACT-2 9' - 0" LP11B LD1LD1 ACT-2 10' - 0" GYP. 8' - 0" LS1A GYP. 6' - 6" GYP. 8' - 0" LW1LW1 LW1 LW1 WAP LW1LW1 GYP. 8' - 10" GYP. 8' - 10" LC1CLC1C LC 1 D LC1C LC1C LA1 LA1 LA1 LA1 LC1D LC1D LC1D LC1D LC1D LP2 LD1 LD1 LD1 LD1LD1LD1 LA2 LD1 LD1 LC3A 5'- 7 " LC3B LC3B 5' - 7 " ACT-1 8' - 0" LA1 LA1 LA2 LA2 9'-0"A.F.F. LA1 LA1 LA1 LA1LA1LA1 LD1 LD1 LC 1 C LS1B LP4 EXIST. 10' - 4" EXIST. 10' - 4" EXIST. 10' - 4" 6 6 6 6 6 6 LS2C LS2C LS2C LS2CLS2C 111 COAT CLOSET GYP. 9' - 0" 2ND LEVEL EGRESS STAIRS LC3A LL1 LL1 3'-0" 4'-0" LW3 AL I G N 7 LD1 LD1 LD1 ALIGN LD1 LD1 LD1 EQ3'-3"EQ GYP. 9' - 0" LD1 LD1 LL1 LA2 4'-0" A-502 3_________________ A-502 3_________________ TYP. TYP. A-502 4_________________ A-502 7_________________TYP. A-502 7_________________ A-502 7_________________ LC 1 C LC 1 C LC 1 C A-502 7_________________ A-502 3_________________ A-502 3_________________ ACT-1 10' - 7" A-502 10_________________ A-502 10_________________ A-502 3_________________ A-502 7_________________ AL I G N ALIGN ALIGN AL I G N AL I G N A-502 8_________________ A-502 4_________________ A-502 7_________________ A-502 7_________________ A-502 7_________________ A-502 5_________________ A-502 9_________________ 10 1/4" 1'- 4 " 1'- 4 " 1' - 4 " 1'- 4 " 10 1/4" 10 1/4" A-502 11_________________A-502 11_________________ A-502 10_________________ A-502 8_________________HSC C HS C C 8 C C C C C C 10'-6 1/2" 5'-4" 5'-6" 7'-8" 5'-8" 5'-2" 7' - 6 1 / 2 " 2'- 6 " EQ EQ EQ EQ 1'-2 1/4" S S S S C EQ 2'-6"EQ EQ 2'- 6 " EQ EQ2'-6"EQ EQ 2'-6"EQ EQ2'-6"EQ LA1 LA1 2'- 4 " 2' - 4 " 2'- 4 " 2' - 4 " 2'- 4 " 8'-5" 10'-0" 11'-5"6'- 4 " 6'- 7 " 6'- 1 1 " 4'-0"2'-5"2'- 3 " EQ EQ 4'-0"2'-5" 9 9 4 104B NIGHT DEPOSIT NICHE EQEQ EQEQEQ EQ EQ EQ 1'- 6 " 1'-6" 1' - 6 " 1'-6" 2' - 9 1 / 2 " OS OS OS OSPS OS PS PS PS PS T T 1'-8 1/2" T LA1 1 1 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 REFLECTED CEILING PLAN BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 AS INDICATED A-101 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 1/4" = 1'-0"REFLECTED CEILING PLAN 1 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 LL 10/28/2024 3/A-501 4/A-501 4/A -50 1 4/A -50 1 3/A -50 1 5/A-5011/A-5011/A-5011/A-5012/A-501PRIMING AND PAINTING 1. ALL WALLS TO BE PAINTED PT-1 AND WALL BASES TO BE RB-1, TYP. UNO. 2. ALL METAL SURFACES TO BE PRIMED ACCORDING TO MANUFACTURER'S STANDARDS AND RECEIVE A SEMIGLOSS FINISH, TYP. UNO. 3. GC TO SKIM COAT ALL CORE, PERIMETER, AND EXISTING COLUMNS AS REQUIRED TO GUARANTEE PLUMBNESS AND EVENNESS PRIOR TO FINAL PAINT/FINISH APPLICATION. 4. ALL WALLS WITH GRAPHIC MURALS OR DECALS TO HAVE LEVEL 5 FINISH AND PRIMER AS DIRECTED BY SIGN VENDOR. COORDINATE WITH SIGN VENDOR FOR PRIMER SPEC AND TIMING OF APPLICATION, SEE BELOW FOR ADDITIONAL NOTES. ENSURE THAT WALL IS FREE FROM DEVICES, COORDINATE WITH POWER / DEVICE PLAN AND ALL TRADES AS REQUIRED. 5. PROVIDE PRIME COAT ONLY BEHIND AREAS TO BE COVERED WITH MILLWORK, WALLCOVERINGS, PANELS, ETC. 6. PROVIDE FINISH PAINT AT ALL WALL AREAS THAT ARE EXPOSED BEHIND ANY APPLIED MILLWORK, PANELS, CONSTRUCTION, ETC. DUE TO REVEALS, JOINTS, END CONDITIONS, ETC. 7. SEE ELEVATIONS FOR ADDITIONAL FINISH INFORMATION. 8. SEE DOOR SCHEDULE SHEET A-600 FOR DOOR AND FRAME FINISH INFORMATION. 9. SEE POWER AND DEVICE PLAN FOR ADDITIONAL NOTES PERTAINING TO DEVICE AND COVER PLATE FINISH. 10. PAINT FINISHES AT ALL WALLS AND COLUMNS TO HAVE A GLOSS VALUE OF 6-9; DOORS, FRAMES, AND CONVECTORS TO HAVE A GLOSS VALUE OF 30-40. 11. ALL WALLS WITH GRAPHICS OR ARTWORK SHALL HAVE A LEVEL 5 FINISH. ALL OTHER WALLS SHALL HAVE A LEVEL 4 FINISH. GENERAL 1. SEE FINISH SCHEDULE SHEET A-602 FOR ALL MATERIAL SPECIFICATIONS AND CONTACT INFORMATION. 2. GC TO REVIEW AND FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PREPARATION AND INSTALLATION METHODS. 3. ALL FINISHES TO BE EVENLY APPLIED AND FREED FROM ALL SAGS, RUNS, CRAWLS, BRUSH MARKS, OR OTHER DEFECTS. 4. ALL FINISH ALTERNATES TO BE PRESENTED TO ARCHITECT FOR APPROVAL PRIOR TO PURCHASE. SEE ADDITIONAL NOTES PERTAINING TO MATERIAL SUBSTITUTIONS AND SUBMITTALS, SHEET G-102. 5. ALL PRODUCTS TO BE PURCHASED FROM CONSISTENT PRODUCT RUN OR LOT. 6. PROVIDE 3-5% ATTIC STOCK FOR ALL MATERIALS, INCLUDING CARPET. CONFIRM FINAL QUANTITIES WITH OWNER. CODE & STANDARDS 1. ALL FINISHES TO MEET MINIMUM CODE REQUIREMENTS. 2. STONE AND TILE FLOORING SPECIFIED FOR WET CONDITIONS TO BE SLIP-RESISTANT WITH DYNAMIC COEFFICIENT OF FRICTION OF 0.42 OR GREATER. 3. WALL, FLOOR, AND CEILING FINISHES SHALL NOT EXCEED FLAME SPREAD CLASSIFICATIONS IN IBC TABLE 803.13 AND SECTION 804. 4. INTERIOR FLOOR FINISH MATERIALS SHALL COMPLY WITH IBC SECTION 804. FLOORING, BASE, AND FLOOR TRANSITIONS 1. SEE FLOORING DETAILS SHEET A-501 FOR TRANSITION DETAILS. 2. ALL FLOOR FINISH TRANSITIONS TO OCCUR AT CENTERLINE OF DOOR, TYP. UNO. 3. GC TO INSPECT SLAB AND PROVIDE SMOOTH FINISH PRIOR TO FLOORING INSTALLATION. FLASH PATCH FLOOR TO LEVEL AREAS WHERE TWO DIFFERENT HEIGHT FINISHES MEET. 4. ALL FLOORING MATERIALS TO BE INSTALLED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. 5. FLOOR FINISHES TO EXTEND BELOW MILLWORK, TYP. UNO. 6. ALL CARPET SEAMS TO ADJACENT CARPET AND/OR ALTERNATE FLOORING TO BE HEAT MOLDED. 7. INSTALL COVE BASE OVER CARPETING AND TILED FLOORING AS REQUIRED. 8. ALL VINYL AND RUBBER BASE TO BE ROLLED GOODS. FOUR-FOOT LENGTHS ARE NOT ACCEPTABLE AND WILL NOT BE APPROVED. 9. SEE MOHAWK GROUP 2D VISUALIZATION PACKAGE FOR CARPET AND LVT INSTALLATION DIAGRAMS AND QUANTITIES. STONE/TILE 1. GC TO PROVIDE INSTALLATION DRAWINGS OR SHOP DRAWINGS FOR ALL TILE / STONE FLOORING FOR APPROVAL PRIOR TO INSTALLATION. 2. ALL STONE, TILE, WALL, AND FLOOR GROUT FINISHES TO BE SEALED PER MANUFACTURER'S SPECIFICATIONS. 3. ALL GROUT SPECIFICATIONS, JOINT WIDTHS, AND COLORS TO BE APPROVED BY ARCHITECT PRIOR TO INSTALLATION. SEE FINISH SCHEDULE SHEET A-602 FOR GROUT SPECIFICATIONS. 4. PROVIDE FULL CONTACT MORTAR ON ALL TILES. 5. PROVIDE EXPANSION JOINTS AS PER TCNA/EJ-171 CURRENT EDITION. COORDINATE LOCATION AND COLOR OF EXPANSION JOINTS WITH ARCHITECT PRIOR TO INSTALLATION. 6. PROVIDE CRACK ISOLATION MEMBRANE PER ANSI 118.12/10 AS MANUFACTURED BY MAPEI, MAPELASTIC, AQUADEFENSE, OR APPROVED EQUAL. 7. WHERE WALLCOVERING AND CERAMIC WALL TILE HAS AN EXPOSED EDGE OR DOES NOT TERMINATE INTO AN INSIDE CORNER, PROVIDE ALUMINIUM EDGE TRIM (I.E. SCHLUTER JOLLY), TYP. UNO. SEE DETAILS SHEET A-501 8. GC TO PROVIDE INSTALLATION DIAGRAMS FOR FLOOR AND WALL TILE FOR REVIEW AND APPROVAL BY ARCHITECT. SUSTAINABILITY 1. ALL ADHESIVES AND PAINT FINISHES TO BE LOW VOC LATEX UNO. 2. ALL WOOD STAINS OR SEALANTS TO CONTAIN NO ADDED UREA-FORMALDEHYDE RESINS. APPLIED GRAPHICS AND CUSTOM SIGNAGE: 1. GC TO COORDINATE WITH SIGNAGE VENDOR / INSTALLER FOR PREFERRED PRIMER SPECIFICATION AT ANY / ALL WALLS TO RECEIVE LEVEL 5 FINISH UNDERNEATH APPLIED GRAPHICS. 2. IF SIGNAGE VENDOR DOES NOT PROVIDE A PREFERRED PRIMER, USE ZINSSER GARDZ PROBLEM SURFACE SEALER. FOLLOW PRIMER MANUFACTURER'S INSTRUCTIONS FOR APPLICATION AND ALLOW THREE DAYS BETWEEN PRIMER APPLICATION AND GRAPHICS INSTALLATION TO ALLOW FOR OFF- GASSING. GENERAL NOTES -FINISH PLAN KEYNOTES -FINISH PLAN 1 MEDIA SLAT WALL, SEE DETAILS SHEET A-506. 2 CUSTOM MURAL GRAPHIC ON OUTSIDE FACE OF EXISTING STOREFRONT, TO BE PROVIDED AND INSTALLED BY BMO VENDOR. 3 CENTER WALK-OFF MAT ON DOOR OPENING. LEGEND -FINISH PLAN AREA NOT IN CONTRACT (N.I.C.) NAME ###ROOM NAME AND NUMBER #KEYNOTE FLOOR FINISHES FLOOR TRANSITION, SEE DETAILS FINISH TAG, SEE FINISH SCHEDULEXXX 4 REFER TO BRAND BOOK BY BMO SIGN VENDOR AND TYPICAL FILM INSTALLATION DETAIL ON SHEET A-601 FOR FILMS ON OFFICE FRONTS, COUPON BOOTH / ENCLAVE DOOR. GLAZING FILMS ARE PROVIDED AND INSTALLED BY BMO VENDOR. 5 CUSTOM GRAPHICS AT BOTTLE FILLING STATION / DRINKING FOUNTAIN WALL, PROVIDED AND INSTALLED BY BMO VENDOR. GC TO PROVIDE A LEVEL 5 FINISH ON WALL AND PRIMER AS DIRECTED BY SIGN VENDOR. COORDINATE WITH SIGN VENDOR FOR PRIMER SPEC AND TIMING OF APPLICATION. 6 FLOOR DRAIN, REFER TO PLUMBING DRAWINGS. 7 FRAMED ARTWORK PROVIDED AND INSTALLED BY BMO VENDOR. 8 EXISTING VAULT THRESHOLD TO BE FLUSH WITH CARPET. 9 PROVIDE PL-3 ALL EXPOSED SURFACES. FLOAT FLOOR AS REQUIRED. CPT-1, CPT-2A, CPT-2B, CPT-3A, CPT-3B, CPT-4A, CPT-4B LVT T-1 VCT-1, VCT-2 EXISTING CONCRETE CPT-5 M-1 10 REFER TO MOHAWK GROUP 2D VISUALIZATION PACKAGE FOR CUSTOM CARPET PATTERN THIS AREA. 11 CARPET TILE CTP-4A SHALL BE INSTALLED TO INSIDE EDGE OF THE ALTOS WALL PARITIONS AT SLIDING DOOR LOCATIONS. 12 EXISTING CONCRETE FINISH TO REMAIN. 13 GC TO PATCH TILE FLOORING TO MATCH EXISTING TILE IN ENTRY VESTIBULE. 105 ATM / LAN ROOM 106 CMR.3 104 WORK ROOM 100 COMMON VESTIBULE 124 CMR.1 123 CMR.2 122 EMPLOYEE ENCLAVE 121 AB 120 BM 119 COUPON BOOTH 116 CORRIDOR 117 EXISTING SD VAULT 110 STAFF ROOM 109 MEETING ROOM 112 CORRIDOR 113 RESTROOM 114 UNIVERSAL RR 115 JANITOR CLOSET 108 CMR.4 101 BANKING HALL 107 RRB PT-1 CPT-2A RB-1 VW-3 PT-1 CPT-2A RB-1 PT-1 CPT-2A RB-1 PT-1 CPT-1 RB-1 PT-1 CPT-1 RB-1 PT-1 T-1 TB-1 PT-1 T-1 TB-1 PT-1 LVT RB-1 PT-1 LVT RB-1 PT-1 CPT-2A RB-1 PT-1 CPT-1 RB-1 PT-1 CPT-2A RB-1 PT-1 CPT-1 CPT-2A RB-1 PT-1 CPT-1 CPT-2A RB-1 PT-1 CPT-1 CPT-2A RB-1 VW-5 CPT-1 RB-1 PT-1 CPT-2A RB-1 VW-3 PT-1 CPT-1 RB-1 ELECTRICAL ROOM ELEVATOR QM PL-3 PL-3 WT-26 6 WT-2 PT-1 T-1 TB-1 WT-2 6 WT-4 WT-4 PT-9 RSH-1 GF-1A RSH-2 PT-4 PT-7A PT-7A PT-7A VW-3 VW-3 VW-3 VW-3 VW-3 PT-1 VCT-2 RB-1 5 2 PT-7A PT-7A 1 1 4 4 4 4 4 4 4 7 9 9 8 PT-6 4 CPT-2A 10 PT-5 PR20X CPT-3A CPT-3B CPT-4A CPT-4B CPT-1 CPT-2A CPT-2B 10 10 RSH-2 RSH-2 VW-6 PT-7A PT-7A PT-7A M-1 VB-3 RSH-1 111 COAT CLOSET PT-1 LVT RB-1 2ND LEVEL EGRESS STAIRS 7 7 10 11 11 11 11 11 11 5'- 10"5'-0" 3 CPT-3A CPT-3B CPT-4A CPT-4B CPT-1 CPT-2A CPT-2B 10 2'-6"6'-2" 10 ' - 0 " PT-7A RSH-1 SI M MURAL 12 13 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 FINISH PLAN BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-102 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1/4" = 1'-0"FINISH PLAN 1SCALE TRUE NORTH ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 TC1 TC1 CC2A CC2A CC2A CC2A WB-P WB-P RWS-D2 108 CMR.4 109 MEETING ROOM 120 BM 117 EXISTING SD VAULT 122 EMPLOYEE ENCLAVE 123 CMR.2 124 CMR.1 106 CMR.3 105 ATM / LAN ROOM 104 WORK ROOM TC1 CC2A CC2A RWS-SA WB-P CC2A CC2ARWS-SA WB-P TC1 CC3 CC3 TC1 OFR-LS1 WB CB3 BS2 BS2 SK1 CC1 LT2 CC1 LC5LC5 LT1 UL-4 CC3 CC3 TC1 OFR-LS1 WB LC5 LC5 LT2 LC5 LC5 LT1 CC1A LT2 CC1A AVC TC2TC2 TC2 TC2 TC2 TC2 MT6P WB1 TC1 OFR-LS1 CC3 CC3 WB CB3 TC3 TC3 CC2B TS1 CC2B CC2B TS1 WB-P RWS-D2 TS1 WB-P WB-P RWS-SA TC1 TC1 TC1 CB3 CB3 MA2MA2 MA2MA2 MA3 MA2 MA2 MA3 MA3 MA2 107 RRB CC3 CC3 OFR-LS1 WB MA3 100 COMMON VESTIBULE 116 CORRIDOR 114 UNIVERSAL RR 115 JANITOR CLOSET 113 RESTROOM 112 CORRIDOR 119 COUPON BOOTH CC3 CC3 OFR-LS1 TC1 MA3 WB 121 AB 101 BANKING HALL 110 STAFF ROOM ELECTRICAL ROOM ELEVATOR LOC TYP. SC2SC2SC2 SC2SC2SC2 ST1 LT2 LT2 FR4 FR4 FR4 RB SO1 TC1 RB RB RB 111 COAT CLOSET 2ND LEVEL EGRESS STAIRS F3H 1 3 2 4 3 1 2 2 2 2 5 5 2 5 2 5 2 5 5 2 3 5 2 5 5 52 52 5 2 GENERAL NOTES -FURNITURE PLAN 1. THIS DRAWING IS TO BE USED FOR REFERENCE AND COORDINATION PURPOSES ONLY. 2. SEE FURNITURE SCHEDULE ON SHEET A-603 FOR SPECIFICATIONS. 3. GC TO COORDINATE CONTRACTOR'S SCOPE OF WORK WITH INSTALLATION PLAN BY FURNITURE VENDOR. 4. GC TO COORDINATE WITH FURNITURE VENDOR, ARCHITECT, AND ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS DURING ROUGH-IN PHASE. FURNITURE VENDOR TO PROVIDE DIMENSIONED PLAN FOR REVIEW AND APPROVAL PRIOR TO ANY FLOOR CORING, TRENCHING, OR POWER / DATA INSTALLATION. FURNITURE VENDOR TO SNAP LINES FOR WORKSTATION LAYOUT, CONFERENCE TABLES, ETC. AND COORDINATE ALL POWER / DATA FEED LOCATIONS WITH ARCHITECT AND GC. ARCHITECT TO REVIEW AND APPROVE LAYOUT. 5. FURNITURE VENDOR TO CONFIRM LOCATION OF WALL MOUNTED POWER/DATA DEVICES AT OFFICES AND WORKSTATIONS TO ENSURE THERE ARE NO CONFLICTS WITH PEDESTALS, MODESTY PANELS, ETC. 6. FURNITURE VENDOR TO VERIFY ALL FURNITURE QUANTITIES, LOCATIONS, AND SPECIFICATIONS PRIOR TO CLIENT SIGN-OFF AND APPROVAL OF ALL FURNITURE. 7. FURNITURE VENDOR TO FIELD VERIFY ALL AS-BUILT ARCHITECTURAL DIMENSIONS PRIOR TO FURNITURE INSTALL. 8. FURNITURE VENDOR TO MAINTAIN A MINIMUM 44" CLEAR PATH FOR EGRESS. 9. FURNITURE VENDOR TO NOTIFY ARCHITECT AND CLIENT OF ANY DISCREPANCIES OF PRODUCT SPECIFICATIONS IMMEDIATELY. FURNITURE VENDOR IS RESPONSIBLE FOR SIZE VERIFICATION OF ALL FREIGHT ELEVATORS, LOCATING DOCKS, AND DELIVERY PATHWAYS TO INSURE THAT ALL FURNITURE CAN BE DELIVERED TO THE SITE IN SPECIFIED DIMENSIONS. FURNITURE VENDOR TO COORDINATE WITH BUILDING FOR ALL RULES AND REGULATIONS. KEYNOTES -FURNITURE PLAN LEGEND -FURNITURE PLAN AREA NOT IN CONTRACT (N.I.C.) NAME ###ROOM NAME AND NUMBER #KEYNOTE ###FURNITURE TAG 1 FURNITURE VENDOR TO PROVIDE CUTOUT(S) IN MEETING ROOM TABLE FOR EQUIPMENT. COORDINATE WITH BMO IT. 2 ADA COMPLIANT LOCKER. SEE DETAIL 5/A-400. 3 34" MAX HEIGHT ADA COMPLIANT TABLE. SEE DETAIL 3/G-101 AND 5/G-102. 4 KIOSK FOR EMPLOYEE USE ONLY. 5 28"-34" MAX ADJUSTABLE DESK / TABLE HEIGHT, MIN 36" WIDE WITH 30" X 48" CLEAR FLOOR SPACE POSITION FOR PARALLEL APPROACH PER DETAIL 4, SHEET G-102. 2 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 2 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 FURNITURE PLAN BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-103 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 1/4" = 1'-0"FURNITURE PLAN 1 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 2 PLAN CHECK #3 SS DR 2024/11/12 2 ALALLL 10/28/2024 GENERAL NOTES -EQUIPMENT PLAN 1. SEE SHEET A-606 EQUIPMENT SCHEDULE, STAFF ROOM APPLIANCE, RESTROOM ACCESSORIES, PLUMBING AND JANITOR FIXTURE SCHEDULES FOR ALL SPECIFICATIONS. 2. GC AND ELECTRICAL CONTRACTOR TO VERIFY WITH EACH MANUFACTURER OF EQUIPMENT AND OBTAIN SHOP DRAWINGS FROM VENDOR FOR COORDINATION FOR ALL SPECIAL REQUIREMENTS (I.E. PROVIDING AND INSTALLING SPECIALTY RECEPTACLES, ATTACHING END CONNECTORS ON CABLES, OR CABLES TO MACHINES, ETC). IF NOT SPECIFICALLY EXCLUDED FROM CONTRACT AGREEMENT, ALL CONNECTIONS TO BE INCLUDED IN THE SCOPE OF WORK OF THE ELECTRICAL CONTRACTOR. 3. GC TO PROVIDE POWER, LOW VOLTAGE, AND PLUMBING HOOKUPS FOR EQUIPMENT AS REQUIRED PER EQUIPMENT INSTALLATION ISNTRUCTIONS, MANUFACTURER'S RECOMMENDATIONS, AND ALL APPLICABLE CODE. 4. SEE ELECTRICAL PLANS FOR ALL EQUIPMENT REQUIRING THE USE OF DEDICATED CIRCUITS. 5. NOTIFY ARCHITECT IMMEDIATELY IF DISCREPANCIES IN EQUIPMENT INFORMATION OCCUR. CONSULT MANUFACTURER'S INSTALLATION INFORMATION. KEYNOTES -EQUIPMENT PLAN LEGEND -EQUIPMENT PLAN AREA NOT IN CONTRACT (N.I.C.) NAME ###ROOM NAME AND NUMBER #KEYNOTE ###EQUIPMENT TAG 1 GC TO MOUNT 'PUSH FOR ASSISTANCE' BUTTON 6'" OFF OF FRONT EDGE OF COUNTER AND 46" AFF. SEE TYPICAL MOUNTING HEIGHTS -DEVICES, ON SHEET G-101. 2 GC TO INSTALL CHIME AT 48" AFF. COORDINATE FINAL LOCATION WITH CLIENT PROJECT MANAGER AND BRANCH STAFF. SEE TYPICAL MOUNTING HEIGHTS -DEVICES, SHEET G-101. 3 NEW NIGHT DEPOSIT IN EXISTING OPENING. 4 BMO VENDOR TO RELOCATE EXISTING SURROUND (MODEL 9527) FROM EXISTING BRANCH LOCATION. VENDOR TO CONFIRM THAT THE EXISTING SURROUND IS SALVAGEABLE AND ABLE TO BE REUSED AND INSTALLED HERE. 5 BMO TO CONFIRM IF TCR WILL BE RELOCATED FROM EXISTING BRANCH. 6 CAGE AND GATE. 7 NEW SD SAFES WITHIN EXISTING VAULT ROOM TO BE INSTALLED BY DIEBOLD. GC TO COORDINATE WITH DIEBOLD ADDITIONAL INSTALL REQUIREMENTS. 8 GC AND BMO VENDOR TO FIELD VERIFY ALL DIMENSIONS AND COORDINATE DAY GATE CLEARANCES AS NECESSARY. 109 MEETING ROOM 110 STAFF ROOM 112 CORRIDOR 113 RESTROOM 114 UNIVERSAL RR 115 JANITOR CLOSET 119 COUPON BOOTH 116 CORRIDOR 120 BM 121 AB 122 EMPLOYEE ENCLAVE 124 CMR.1 123 CMR.2 100 COMMON VESTIBULE 104 WORK ROOM 105 ATM / LAN ROOM 106 CMR.3 107 RRB 108 CMR.4 101 BANKING HALL DSH-75 PR1 PR2 IC PR1 SB CSCSCS TCR TCR DSH-65 DSH-65 S ELECTRICAL ROOM ELEVATOR ATM 2 1 4 CG CG CG CG CG CG CG CGCG CG LSQ CG 3 ND BC-1 BC-2 FEC 111 COAT CLOSET 2ND LEVEL EGRESS STAIRS CG CG TYP. ALL CORNERS CB FEC CG CG CG SSH SB S-5 CG S-7 FEC 5 CG TYP. ALL CORNERS CG CG CG CG CG CG 6 CG CG SDS SDS 117 EXISTING SD VAULT 1 7 7 8 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 EQUIPMENT PLAN BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-104 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 1/4" = 1'-0"EQUIPMENT PLAN 1 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 LL 10/28/2024 GFI 30 " G F I 38" GFI 38 " G F I 38" GFI 38" 60" 60" AV60" XP AV D P 34 " 34 " 34 " 34 " 38 " 38 " 28" 28" 38" 34 " 34 " 44 " A N A 44 " 44 " 38 " 38 " J 42" DS P SC 72" 72" 72" 72" SC J 42 " 38" GFI 24 " 24 " 24" P P DS 34 " 34 " 38 " 38 " 42" 42" 38" 38" 38" 38" 38" 24 " 38 " 38 " 44" 44" J J 44 " J J J D J GF I J 60 " 60 " 60 "DCDCKP WM HU HU HU HU KP HU HU WM DC DC ALAL DC DC KP AL AL HU HU HU AL HU SC SC HU SC SC J 40 " G F I 96 " 80" 46 " J SC SC J GENERAL NOTES -POWER AND DEVICE PLAN 1. ALL DEVICES TO BE MOUNTED AT 18" AFF, TYP. UNO. SEE TYP. DEVICE MOUNTING HEIGHTS, SHEETS G-102. 2. GC TO CONFIRM IF EXISTING OUTLETS AND DATA PORTS MAY BE REUSED. GC'S ELECTRICAL CONTRACTOR TO REPLACE ALL EXISTING POWER / DATA OUTLETS AND COVER PLATES WITH NEW OUTLETS AND COVER PLATES WHERE REUSED. VERIFY IN FIELD WHETHER EXISTING LOCATIONS WORK WITH PROPOSED PLAN, RELOCATE DEVICES AS REQUIRED. 3. GC TO INSTALL, RELOCATE OR REPLACE ANY THERMOSTATS WITH NEW PER PLAN. ALL THERMOSTATS TO BE WHITE. SEE ENGINEERING DRAWINGS FOR ADDITIONAL REQUIREMENTS. 4. GC TO CONFIRM IF EXISTING LIFE SAFETY DEVICES MAY BE REUSED. PROVIDE NEW EQUIPMENT AS REQUIRED. ALL NEW DEVICES TO MATCH EXISTING DEVICES IN COLOR, SIZE, MAKE, MODEL, AND FUNCTION UNLESS AN UPGRADED DEVICE IS REQUIRED BY LOCAL CODE OR UNLESS EXISTING DEVICES ARE NO LONGER AVAILABLE FOR PURCHASE. 5. ELECTRICAL CONTRACTOR TO REUSE EXISTING CIRCUITS WHERE POSSIBLE. 6. DIMENSIONS ARE INDICATED TO CENTER OF DEVICE OR GROUPING, UNO. 7. SEE SHEET G-102 FOR TYPICAL MOUNTING HEIGHTS, DEVICE LOCATIONS, AND ORIENTATIONS. SEE INTERIOR ELEVATIONS AND MILLWORK DETAILS FOR ADDITIONAL INFORMATION. 8. FOR DEVICE LOCATIONS, ARCHITECTURAL DRAWINGS SUPERSEDE MEP DRAWINGS. IN CASE OF MAJOR DISCREPANCIES BETWEEN MEP AND ARCHITECTURAL DRAWINGS, CONTACT ARCHITECT PRIOR TO INSTALLATION. 9. HEIGHTS AND LOCATIONS OF ALL DEVICES FOR MONITORS OR OTHER WALL- OR CEILING-MOUNTED EQUIPMENT TO BE COORDINATED WITH AV VENDOR PRIOR TO ROUGH-IN. 10. LOCATIONS OF ALL POWER / DATA STUB-UPS AND FLOOR BOXES FOR WORKSTATIONS, CONFERENCE TABLES, OR ANY OTHER FURNITURE TO BE COORDINATED WITH FURNITURE VENDOR. OUTLINES OF WORKSTATIONS AND TABLE LEGS TO BE IDENTIFIED ON FLOOR SLAB FOR REVIEW AND COORDINATION WITH OWNER, ARCHITECT, AND FURNITURE VENDOR PRIOR TO CORING. 11. ALL OTHER FLOOR DEVICE LOCATIONS TO BE COORDINATED IN FIELD BY ARCHITECT PRIOR TO CORING. 12. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ALL REQUIRED LOW VOLTAGE CABLING, TERMINATIONS, CONDUITS, PULL BOXES, HOME RUNS, WALL JUNCTION BOXES, PLASTER RINGS, ETC. FOR INSTALLATION OF ALL VOICE/DATA DEVICES, CABLES, SECURITY DEVICES, ETC. GC TO COORDINATE WITH OWNER'S VENDOR FOR REQUIREMENTS. 13. GC AND LOW-VOLTAGE CONTRACTOR TO REVIEW ALL BMO TELECOM STANDARDS FOR BMO SMALL BRANCH REMODELS AND NEW LAN ROOMS. REVIEW OTHER RELEVANT BMO TELECOM STANDARDS AS REQUIRED FOR PROJECT SCOPE AND TYPE. COORDINATE WITH BMO IT. 14. GC AND LOW-VOLTAGE CONTRACTOR TO PROVIDE ALL MATERIALS AND LABOR FOR THE INSTALLATION OF A COMPLETE COMMUNICATIONS DISTRIBUTION SYSTEM INCLUDING ALL HORIZONTAL CABLES, BACKBONE CABLES, TERMINATION PANELS, PATCH CABLES, OUTLETS, CROSS-CONNECTS, AND ANY OTHER COMPONENTS AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. 15. SEE EQUIPMENT PLAN SHEET A-104 AND EQUIPMENT SCHEDULE SHEET A-606 FOR ADDITIONAL INFORMATION. GC AND ELECTRICAL CONTRACTOR TO REVIEW ALL POWER / DATA REQUIREMENTS FOR SCHEDULED EQUIPMENT AND CONFIRM THAT INDICATED POWER / DATA DEVICE QUANTITIES ARE SUFFICIENT FOR DEVICE OPERATION. PROVIDE ADDITIONAL DEVICES AS REQUIRED, COORDINATE LOCATIONS OF ANY NEW DEVICES WITH ARCHITECT PRIOR TO INSTALLATION. 16. ALL CONDUITS TO BE CONCEALED. NO EXPOSED CONDUITS. 17. GC TO COORDINATE WITH BMO VENDOR AND EQUIPMENT CUT SHEETS FOR INSTALLATION OF ATM, ATM SURROUND, NIGHT DROP, CASH SAFES, ETC. DEVICE NOTES: 1. ALL DEVICES AND LIGHTING CONTROLS TO BE GANGED WITH A SINGLE FACEPLATE, TYP. UNO. GC TO SUBMIT SHOP DRAWINGS INDICATING SIZE, LOCATION, ENGRAVED TEXT (WHERE APPLICABLE), ETC. FOR ARCHITECT'S REVIEW. 2. FOR GANGED SWITCHES AND COVER PLATES, BUTT DIMMERS AND SWITCHES TOGETHER WITHIN SAME GANG BOX, TYP. UNLESS REQUIRED TO BE SEPARATE BOX (IE. LOW VERSUS HIGH VOLTAGE). IF A GANG OF SWITCHES REQUIRE SEPARATE BOXES (IE. DUE TO LOW VERSUS HIGH VOLTAGE), INSTALL BOXES AS TIGHT AS POSSIBLE AND PROVIDE COVER PLATE WITH ENGRAVED TEXT, TYP. 3. ALL DEVICES AND FACEPLATES TO BE WHITE, TYP. UNO. ALL OUTLETS ON TILE WALLS SHALL BE STAINLESS STEEL, UNO. ARCHITECT TO PROVIDE ADDITIONAL GUIDANCE AT SUBMITTAL RESPONSE AS REQUIRED. 4. INSTALL ALL WALL BOXES SO AS TO ALLOW DEVICE FACEPLATES TO BE FLUSH WITH ADJACENT WALL SURFACE UNLESS WATTAGE REQUIREMENTS DICTATE OTHERWISE. ALL FACEPLATES TO BE INSTALLED TRUE AND LEVEL. 5. INSTALL ALL FLOOR BOXES AND DEVICES AFTER CARPET IS LAID. ALL CUTTING OF CARPET FOR FLOOR OUTLETS SHALL BE BY CARPET INSTALLER AND COORDINATED WITH ELECTRICAL CONTRACTOR. 6. FLOOR BOXES TO BE A GRAY POWDER COATED FINISH. 7. FACE PLATES IN TILE WALLS TO BE STAINLESS STEEL. ARCHITECT TO PROVIDE ADDITIONAL GUIDANCE AT SUBMITTAL RESPONSE AS REQUIRED. 8. ISOLATED GROUND (IE.) RECEPTACLE BODIES SHALL BE OF A BASIC COLOR "WHITE" WITH AN ORANGE TRIANGLE TO SYMBOLIZE ISOLATED GROUND. KEYNOTES -POWER AND DEVICE PLAN 1 SEE ENLARGED PLANS AND DETAILS SHEET A-401 FOR LAN ROOM LAYOUT INCLUDING RACK-MOUNTED DEVICES. GC TO PROVIDE ALL SERVER RACKS. GC TO PROVIDE F.T. PLYWOOD BLOCKING IN PARTITIONS FOR ALL WALL-MOUNTED EQUIPMENT. LEGEND -POWER AND DEVICE PLAN AREA NOT IN CONTRACT (N.I.C.) OUTLET - DUPLEX OUTLET - DUPLEX, GFI OUTLET - DUPLEX, DEDICATED OUTLET - QUADRUPLEX OUTLET - QUADRUPLEX, DEDICATED STUB-UP DATA FEEDSTUB-UP POWER FEED DOOR RELEASE BUTTON FLUSH DUPLEX FLOOR OUTLET FLUSH QUADRUPLEX FLOOR OUTLET PANIC / HOLD-UP BUTTON DOOR CONTACT ALARM KEYPAD, MOUNT AT 48" A.F.F. TO TOP OF DEVICE WALL MOUNTED ALARM LIGHT WALL MOUNTED MOTION DETECTOR #KEYNOTE SECURITY / ALARM DEVICES - SEE SECURITY DRAWINGS FOR ADDITIONAL INFORMATION POWER / DATA DEVICES - SEE DEVICE LABELS FOR HEIGHTS A.F.F. WHERE APPLICABLE GFI KP AL WMDC DR HU DDPP ANALOG PHONE CONNECTION (1x) WALL MOUNTED NETWORK OUTLET (2xCAT6E) FLOOR MOUNTED DATA OUTLET (2xCAT6E) FLOOR STUB-UP: (1) QUAD OUTLETS, (2) TELE/DATA PORTS, AND AV WALL MOUNTED HDMI OUTLET WIRELESS ADA PUSHPLATE JUNCTION BOX AV AV ADA SC SECURITY CONNECTIONS NAME ###ROOM NAME AND NUMBER DSDS STUB-UP DATA / SECURITY FEED BIDS BOSCH IDS VV VERINT VIDEO 2 PROVIDE POWER / DATA STUB UP FROM FLOOR INTO FURNITURE CABINET. ELECTRICAL CONTRACTOR TO MAKE CONNECTIONS TO FURNITURE PROVIDED CONDUITS / RACEWAY FOR BOTH POWER AND DATA. GC TO COORDINATE WITH FURNITURE VENDOR FOR EXACT LOCATION. 3 SEE ELECTRICAL, IT, AND AV DRAWINGS FOR POWER / DATA REQUIREMENTS AT MONITORS, TYP. PROVIDE F.T. PLYWOOD BLOCKING IN PARTITIONS FOR ALL WALL-MOUNTED ITEMS AND EQUIPMENT, REFER TO DETAILS SHEET A-500. GC TO COORDINATE ALL DEVICE MOUNTING HEIGHTS WITH AV VENDOR. 4 PROVIDE POWER / DATA / AV AT TABLE LEG. PROVIDE 1-1/2" CONDUIT WITH PULL STRING FROM TABLE LEG TO BACK OF VIDEO FOR A/V. COORDINATE WITH FURNITURE VENDOR FOR EXACT LOCATION. COORDINATE WITH VENDOR A/V DRAWINGS. 7 PROVIDE POWER / DATA BELOW FURNITURE FOR TCR MACHINE. PROVIDE ORANGE AND BLUE CABLING. DO NOT INSTALL DEVICES DIRECTLY BEHIND TCR. COORDINATE WITH FURNITURE FOR DEVICE PLACEMENT. SEE DETAILS ON SHEET A-505. 9 PROVIDE (1) ANALOG DATA PORT FOR CASH ADVANCE. 6 POWER/DATA DEVICES TO BE LOCATED ABOVE COUNTER. COORDINATE WITH FURNITURE VENDOR FOR EXACT LOCATION. REFER TO DETAILS ON SHEET A-505. 5 BUBBLE GRAPHICS WALL TO BE FREE OF ALL DEVICES. 8 PROVIDE (1) DEDICATED POWER RECEPTACLE AND (1) DATA PORT FOR ATM. PROVIDE A JUNCTION BOX PER ATM SURROUND REQUIREMENTS. COORDINATE WITH EQUIPMENT SPECIFICATIONS. 10 POWER/DATA TO BE LOCATED BELOW COUNTER. PROVIDE GROMMETS IN COUNTERTOP ABOVE EACH OUTLET LOCATION, SEE MILLWORK DETAILS FOR GROMMET SPECIFICATION. 11 COORDINATE POWER / DATA DEVICE PLACEMENT WITH FURNITURE VENDOR TO ENSURE ALL OUTLETS ARE ACCESSIBLE WHEN FURNITURE IS INSTALLED. 13 PROVIDE HARDWIRE CONNECTION FOR RESTROOM FAUCET. CONFIRM J-BOX HEIGHT AND LOCATION WITH EQUIPMENT SPECIFICATIONS. 12 PROVIDE HARDWIRE CONNECTION FOR BOTTLE FILLING STATION AND HI-LO DRINKING FOUNTAIN. CONFIRM J-BOX HEIGHT AND LOCATION WITH EQUIPMENT SPECIFICATIONS. JJ 14 CONNECT SECURITY TO SD VAULT, TCRs, ATM, NIGHT DEPOSIT AND CASH SAFE. SEE SECURITY DRAWINGS. 15 GC TO COORDINATE WITH BMO IT AND AV VENDOR FOR CONFERENCE ROOM POWER, DATA AND AV REQUIREMENTS. REFER TO VENDOR AV DRAWINGS. 16 PROVIDE HARDWIRE CONNECTION FOR DISHWASHER. CONFIRM J-BOX HEIGHT AND LOCATION WITH EQUIPMENT SPECIFICATIONS. 17 PROVIDE STAINLESS STEEL FACEPLATES FOR ELECTRICAL OUTLETS AT WALL TILE LOCATIONS. 18 (2) EXISTING ELECTRICAL PANEL LOCATION. SEE ELECTRICAL DRAWINGS. 19 PROVIDE FLUSH FLOOR BOX FOR PLUG-IN KIOSK POWER AND (1) DATA PORT. GC TO COORDINATE WITH FURNITURE VENDOR FOR EXACT LOCATION. 20 GC TO CONFIRM LOCATION AND ELECTRICAL REQUIREMENTS FOR EXTRON KEYPAD WITH VENDOR A/V DRAWINGS. 21 POWER/DATA LOCATED IN FURNITURE SYSTEM. ELECTRICAL CONTRACTOR TO PROVIDE WIRING AND TERMINATION. COORDINATE WITH FURNITURE VENDOR. 22 PROVIDE POWER FOR MOTORIZED WINDOW SHADES CONCEALED WITHIN CEILING SOFFIT IN THIS LOCATION. 23 PROVIDE POWER FOR DOOR OPERATOR ABOVE DOOR. 24 GC TO COORDINATE J-BOX CONDUIT ENTRY THROUGH TOP OF SAFE PER EQUIPMENT SPECIFICATIONS. 106 CMR.3 105 ATM / LAN ROOM 104 WORK ROOM 100 COMMON VESTIBULE 101 BANKING HALL 107 RRB 108 CMR.4 109 MEETING ROOM 110 STAFF ROOM 112 CORRIDOR 115 JANITOR CLOSET 113 RESTROOM 114 UNIVERSAL RR 116 CORRIDOR 119 COUPON BOOTH 120 BM 121 AB 122 EMPLOYEE ENCLAVE 123 CMR.2 124 CMR.1 ELECTRICAL ROOM ELEVATOR 18" 18 11 11 21 2 21 21 19 11 11 10 14 13 16 17 5 12 20 3 15 9 3 3 10 6 2 14 721 11 21 146 7 8 1 14 14 4 2ND LEVEL EGRESS STAIRS 22 22 22 12 4'- 0 " A-401 1 40" GFI ADA 23 13 ' - 1 0 1 / 4 " 9" 4 1 / 2 " 9" 8" 106" 8' - 1 1 " 7 1/2" 5'- 7 " 9" 4 1 / 2 " 9" 4'-6"6" 6"5'-7" ADA 8' - 5 1 / 2 " 117 EXISTING SD VAULT 14 1 24 24 1 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 POWER AND DEVICE PLAN BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-105 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 1/4" = 1'-0"POWER AND DEVICE PLAN 1 1 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 LL 10/28/2024 GENERAL NOTES -ROOF PLAN 1. LOCATE EXHAUST FANS AND VENTS A MINIMUM OF 10'-0" FROM HVAC UNIT AND A MINIMUM OF 5'-0" FROM PARAPET WALLS. 2. ALL JACKS ALL EXTEND A MINIMUM OF 8" ABOVE THE ROOF DECK WITH RAIN COLLARS AND SEALANT TO BE PROVIDED BETWEEN THE TOP OF THE JACK AND THE PIPE AND ALL PLUMBING VENTS MUST RECEIVE 4 LB LEAD FLANGE FLASHING. 3. COORDINATE ALL ROOF OPENINGS AND PENETRATIONS WITH ALL TRADES AND STRUCTURAL DRAWINGS TO AVOID CONFLICTS. PENETRATIONS SHALL BE SEALED WATER TIGHT. 4. ALL ROOF MOUNTED EQUIPMENT SHALL NOT BE VISIBLE IN ANY DIRECTION FROM A POINT FIVE (5) FEET ABOVE GRADE OF THE FINISH FLOOR OF THE BUILDING TO A MAX. DISTANCE OF 1,000 FEET. 5. SHOULD ANY ADDITIONAL ROOF PENETRATION BE REQUIRED, GC SHALL REAPAIR AND PATCH PER MANUFACTURERS RECOMMENDATIONS. 6. GC TO VERIFY THAT ROOF DRAINS ARE FREE OF ANY DEBRIS. 7. FOR TENANT IMPROVEMENTS, GC TO USE LANDLORD ROOFER. LEGEND -ROOF PLAN #KEYNOTE EXISTING CONSTRUCTION TO REMAIN SECURITY / ALARM DEVICES - SEE SECURITY DRAWINGS FOR ADDITIONAL INFORMATION ROOF HATCH CONTACTRHC KEYNOTES -ROOF PLAN 1 EXISTING PARAPET TO REMAIN, TYPICAL ENTIRE ROOF. 2 EXISTING ROOF DRAINS TO REMAIN. 3 EXISTING PLUMBING VENT TO REMAIN. 4 EXISTING ROOFTOP UNITS & CONDESING UNITS TO REMAIN. 5 EXISTING EXHAUST FAN, SEE MECHANICAL AND ELECTRICAL DRAWINGS. 6 EXISTING ROOF ACCESS HATCH TO REMAIN. PROVIDE ROOF HATCH CONTACT. SEE SECURITY DRAWINGS. 7 NEW CONDENSING UNIT SECURED TO ROOF CURB. SEE MECHANICAL DRAWINGS FOR DETAILS. 1 RTU CU-3 CU-2 CU-1 RTU RTURTU RTU CU-4 2 2 3 4 4 4 46 4 4 4 4 4 5 5 BMOBMO BMO BMO OTHERS OTHERS OTHERS OTHERS OTHERS RHC BMOCU-5 7 M001 1_________________ THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 ROOF PLAN BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-106 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE TRUE NORTH 1/4" = 1'-0"ROOF PLAN 1 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 ROOF DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-107 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALESCALESCALESCALE SCALESCALE MULTI-PIPE ENCLOSURE DETAIL 1PIPE SUPPORT DETAIL 2PLATFORM DETAIL 3CRICKET DETAIL 4 CONE (PRE-FABRICATED) PIPE PENETRATION 5PIPE PENETRATION - FIELD WRAP 6 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 LEGEND -EXTERIOR ELEVATIONS GENERAL NOTES -EXTERIOR ELEVATIONS 1. ALL EXTERIOR BUILDING ELEMENTS ARE EXISTING TO REMAIN, TYP. UNO. AREA NOT IN CONTRACT (N.I.C.) XXX FINISH TAG, SEE FINISH SCHEDULE EXTENT OF GRAPHIC GLASS FILM KEYNOTES -EXTERIOR ELEVATIONS 1 NEW THRU-WALL ATM IN EXISTING OPENING. SURROUND TO BE RELOCATED FROM EXISTING BRANCH BY BMO VENDOR. (ATM SURROUND 9527 -48"W X 78"H) 2 EXISTING DOUBLE DOORS AND STOREFRONT SYSTEM TO REMAIN. 3 EXISTING PLANTER TO REMAIN. 4 NEW THRU-WALL NIGHT DEPOSIT BY BMO VENDOR IN EXISTING OPENING. 5 EXISTING SIGN TO BE REMOVED AND REPLACED BY SIGN VENDOR UNDER SEPERATE PERMIT. GC TO COORDINATE RELOCATED SIGN POWER LOCATIONS WITH SIGN PERMIT AND SHOP DRAWINGS, PATCH AND REPAIR STUCCO FINISH AS REQUIRED. 6 NEW EXTERIOR WALL PACK. REMOVE ADJACENT LIGHT SCONCES, PATCH AND REPAIR TO MATCH EXISTING FINISHES. 7 NEW BLUE GLAZING FILM BY SIGN VENDOR UNDER SEPERATE PERMIT. 8 EXISTING ADDRESS NUMBERS TO REMAIN. 9 EXISTING CORNICE AND ARCHITECTURAL MOLDING TO REMAIN. 10 EXISTING STONE VEENER AND TRIM CAP TO REMAIN, TYP. 11 EXISTING STUCCO / PLASTER FINISH TO REMAIN. PATCH, REPAIR AND PAINT TO MATCH AS NEEDED. 12 EXISTING WALL SCONCE TO REMAIN. PROTECT IN PLACE. LEVEL 1 0" 5 99 9 9 1312241010 10 11 11 1111 11 11 10 9 TYP. 99 1045 87TYP.A-300 1 12 6 9'- 0 " CO O R D I N A T E W I T H E X I S T I N G B U I L D I N G S T R U C T U R E 12 ' - 8 " T T T T T T TTTTT TTT THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 EXTERIOR ELEVATIONS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-200 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 3/8" = 1'-0"EXTERIOR ELEVATION 1 SCALE ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 124 123 120 OPEN TO BEYOND OPEN TO BEYOND OPEN TO BEYOND OPEN TO BEYOND RB-1 A-506 3 PT-1 PL-3 PL-3 DSH-65DSH-65 GLASS FILM; REFER TO DETAILS ON A-601 AND FINISH SCHEDULE, TYPICAL 9'- 0 " PT-7A 3'- 2 " PT-1 M121-06M121-05 TEMPERED SAFETY GLASS, TYP.TEMPERED SAFETY GLASS, TYP. PR2 IC 2'- 4 " 3' - 2 " T Y P . PL-4 PT-1 PT-1 PL-4 2'- 0 " 3'- 0 " 3'- 0 " 105A A-504 18_________________ RB-1 M104-01 PL-1 PL-1 5"11 1/2"5"1'-9"5"1'-9"5"1'-9" 2'- 1 0 " A-504 9_________________A-504 16_________________ 2'-1"2'-1"2'-1"2'-6"1" (4) EQUAL 8'-9"1" 10 3 / 4 " 1/ 4 " 2'- 1 1 1 / 4 " 2'- 6 " 2'- 6 " PR1 2'- 1 0 " T Y P . 1'- 6 " 1'-3"5"2'-0"5"1'-0" PL-4 PT-7A PL-4 PL-1 PT-1 A-504 9_________________ A-505 5_________________ TY P . 1'- 6 " 1'-3"5"5"5" GLASS FILM; REFER TO DETAILS ON A-601 AND FINISH SCHEDULE, TYPICAL RB-1 M107-01 PL-1 FINISHED SIDE PANEL FINISHED SIDE PANEL CB 104 1 3/4"1"2'-4 1/2"2'-4 1/2"1" 1 3/4"1"2'-4 1/2"2'-4 1/2"1"5" 4'-11" EQ.EQ. PL-4 FINISHED PANEL TEMPERED SAFETY GLASS, TYP. 10 3 / 4 " 1/ 4 " 2'- 1 1 " 2'- 2 " 2'- 1 0 " EQ 5"2'-0"5"EQ 3'- 2 " T Y P . 5"5"5"1'-3" 1'- 6 " T Y P . A-505 5_________________ A-504 9_________________ PL-1 PL-4 PT-7A PL-4 PT-1 RB-1 GLASS FILM; REFER TO DETAILS ON A-601 AND FINISH SCHEDULE, TYPICAL M107-02 PL-1 FINISHED SIDE PANEL 1"EQ EQ 1" 5"1" (2) EQUAL 4'-9"1"1 3/4" PL-4 FINISHED PANEL FINISHED SIDE PANEL TEMPERED SAFETY GLASS, TYP. 106108 9' - 0 " RB-1 PT-1 GLASS FILM; REFER TO DETAILS ON A-601 AND FINISH SCHEDULE, TYPICAL 1' - 6 " T Y P EQEQ EQEQ TEMPERED SAFETY GLASS, TYP. TEMPERED SAFETY GLASS, TYP. TEMPERED SAFETY GLASS, TYP. 101A PERFORATED GRAPHIC MURAL BY SIGN VENDOR AA A A A A A TTTT T T T T TT TT T T T THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 INTERIOR ELEVATIONS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-201 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE SCALE 1/2" = 1'-0"BANKING HALL 101 - EAST 1 1/2" = 1'-0"WORK ROOM 104 - WEST 6 1/2" = 1'-0"RRB 107 - NORTH 4 1/2" = 1'-0"RRB - 107 - SOUTH 3 1/2" = 1'-0"BANKING HALL 101 - WEST 2 1/2" = 1'-0"VESTIBULE - INTERIOR STOREFRONT 5 SCALE SCALESCALE SCALE ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 PL-3 VW-5 2' - 6 " EQ EQ M119-01 RB-1 A-504 12_________________ 2' - 6 " 2' - 0 " M119-01 PL-3 VW-5 RB-1 EQEQ LW3 RB-1 PL-1 PL-1 PL-4 M121-01 PT-7A PL-4 PT-1 A-504 18_________________ 3'- 0 " 2'- 6 " 2'- 6 " A-504 5_________________ EQ 5"EQ 1'- 6 " 8'- 0 " A-504 12_________________ 1"2'-4"2'-4"1" PR1 PL-1 PL-1 PL-4 M121-02 PT-7A PL-4 PT-1 3'- 0 " 2'- 6 " 2'- 6 " EQ 5"1'-10"5"EQ 2'- 1 0 " T Y P . A-504 18_________________ 8'- 0 " A-504 9_________________ 1"2'-4"2'-4"1" CSCSCS 3' - 0 " 1' - 8 " 3'- 4 " EQ 5"5"EQ PL-1 M121-03 PT-7A PL-4 PT-1 A-504 18_________________ A-504 13_________________ 3' - 8 " T Y P . CLEAR 4'-10" 8'- 0 " 1"2'-4"2'-4"1" PL-1 PL-1 PL-4 M121-04 PT-7A PL-4 PT-1 2'- 2 " 2'- 1 0 " 3' - 2 " T Y P . A-504 18_________________ 3'- 0 " EQ 5"2'-0"5"EQ 8'- 0 " A-504 9_________________ 1"2'-4"2'-4"1" S PL-4 PT-1 PL-1 PL-1 3'-6"2'-3"5" FR4 FR4 FR4 3' - 2 " T Y P . 3'- 0 " 2'- 6 " 2'- 6 " M122-01 1"2'-6"2'-6"3"2'-0" A-504 9_________________RB-1 6'- 8 " 11'-6" RB-1 PL-1 3'-6"5"5"5'-8" PT-1 PL-1 PL-4 PL-4 M122-01 3'- 0 " 2'- 6 " 2'- 6 " PT-1 PT-1 1' - 6 " T Y P . A-504 18_________________ A-504 10_________________A-504 5_________________A-504 12_________________ 1"3'-0"3'-0"3'-0"3'-0"3'-0"1" A-501 8_________________ A-504 6 MS-2 INSTALL FULL TILE AT TOP ROW WHP MS-13' - 0 " & W A L L F U R R I N G , S E E P L A N 4'- 0 " T O P O F W A L L T I L E WATER HEATER; REFER TO PLUMBING DRAWINGS PT-1 TB-1 WT-2 A-501 10_________________ EXISTING JUNCTION BOX A-501 8_________________ A-501 10_________________ A-504 6_________________ TB-1 PT-1 4' - 0 " 3'- 0 " 6'- 5 " WT-2 MS-1 MS-2 INSTALL FULL TILE AT TOP ROW WATER HEATER; REFER TO PLUMBING DRAWINGS EXISTING MOP HOLDER (RELOCATED) WHP 4'-1" 4' - 1 1 " C L M O P H O L D E R A-501 7_________________ PT-1 TB-1 115 4' - 0 " WT-2 MS-1 A-501 7_________________ EQEQ PT-1 TB-1 1' - 6 " PT-6 M116-01 PL-4 PL-1 2'- 1 0 " 2'- 2 " 3'- 0 " PL-4 PT-1 EQ EQ 3'- 2 " A-504 18_________________ A-504 15_________________ 1"3'-10"1" 1"1'-11"1'-11"1" PT-1 RB-1 PL-1 SB 2'- 6 " 3'- 2 " 6'-7"2'-5" 8'-2 1/2"6" 1' - 6 " OPEN TO BEYOND M122-02 PT-1 A-504 13_________________ A-504 12_________________RB-1 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 INTERIOR ELEVATIONS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-202 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALESCALESCALESCALE 1/2" = 1'-0"COUPON BOOTH 119 - NORTH 101/2" = 1'-0"COUPON BOOTH 119 - WEST 11 1/2" = 1'-0"AB 121- MILLWORK 1 11/2" = 1'-0"AB 121- MILLWORK 2 21/2" = 1'-0"AB 121- MILLWORK 3 31/2" = 1'-0"AB 121- MILLWORK 4 4 1/2" = 1'-0"EMPLOYEE ENCLAVE 122 - EAST 13 1/2" = 1'-0"EMPLOYEE ENCLAVE 122 - NORTH 12 SCALESCALESCALESCALE 1/2" = 1'-0"JANITOR'S 115 - EAST 51/2" = 1'-0"JANITOR'S 115 - NORTH 61/2" = 1'-0"JANITOR'S 115 - SOUTH 71/2" = 1'-0"JANITOR'S 115 - WEST 8 SCALESCALE 1/2" = 1'-0"CORRIDOR 116 - WEST 14 SCALESCALESCALE 1/2" = 1'-0"EMPLOYEE ENCLAVE 122 - WEST 9 SCALE ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 EXIST. LANExist. MiscPanels - On Wallprinter RRBRRBRRBRRBEXIST.22'-7"28'-1"20'-4"CH: 8' - 0"303.93 SFROOMENTRANCECMR.3CMR.4LOUNGE.2NEW ATMCageBACKSPLASH TILEACCENT WALL APPLICATION - PAINTDIGITAL MERCHANDISING FEATUREFEATURE WALL: WOOD SLATSACCENT WALL APPLICATION - VWCACCENT WALL APPLICATION - MURALBR GLASSART A-505 2 PT-1 PT-1 RB-1 EQ EQ M111-01 S-5 RB-1 PT-1 G-103 8 GAP 2" MAX. GAP 2" MAX. AT C E I L I N G 4" M A X . G A P MA X . G A P 2" M A X . FLOOR ANCHORS PER MFR. MANUFACTURER: WIRE CRAFTERS CONTACT: (800) 626-1816 MESH: 2"x2" / 10 GAUGE FINISH: GRAY DOOR LEVER TYPE: 06 RHODES LEVER NOTE: GC TO PROVIDE SHOP DRAWING FOR REVIEW. CE I L I N G H E I G H T 9'- 0 " MODULAR WOVEN MESH PANEL, TYP. 2"X2"X14 GAGE STEEL POST AS REQ'D BY MFR. CYLINDER ADA LEVER LOCK BY CAGE MFR. TRANSOM PANEL ABOVE DOOR CAGE DOOR (3'-0 WIDE x 7'-3 1/4" HIGH) STIFFENER TO BE PROVIDED AS REQUIRED BY MFR. DOOR CLOSER PER MFR. DIAGONAL BRACING STRAP TO WALL. DIAGONAL BRACING STRAP TO WALL. GC TO REMOVE TEMPORARY PLYWOOD AND COORDINATE WITH VENDOR TO FIELD VERIFY EXISTING OPENING DIMENSIONS AND HEIGHT ABOVE FINISH FLOOR. EXISTING 6" HIGH X 34" WIDE X 36" DEEP CONCRETE CURB. GC TO INCLUDE IN BID POTENTIAL REMOVAL UPON FIELD VERFICATION OF OPENING DIMENSIONS. HOLD 2'-2" MIN 2'-2" LAN ROOM CABINETS, SEE A-401 FOR DETAILS GC TO REVIEW "HOLD" DIMESIONS AND COMMUNICATE ANY DISCREPANCIES TO ARCHITECT 2' - 7 5 / 8 " RO : ± 2 ' - 3 7 / 8 " SURFACE MOUNTED JUNCTION BOX WITH BLANK PLATES BY GC FOR ATM SURROUND LIGHTING. RO: ± 2'-0 5/8" CAGE AND LATERAL AND HORIZONTAL WALL BRACING BY MANUFACTURER. 2'- 7 " 2'- 5 " M I N . 4"3'-3"3'-4"3 1/2"9 1/2" GC TO REMOVE EXISTING PLYWOOD AND CONFIRM ROUGH OPENING HEIGHT AND DIMENSIONS HOLD 7'-6" EX I S T . O P E N I N G 2'- 1 3 / 8 " 2'- 7 1 / 4 " NIGHT DEPOSIT TO BE CENTERED BETWEEN EXTERIOR MULLIONS EQ EQ APPROXIMATE AREA TO BE INFILLED GC TO REMOVE EXISTING PLYWOOD AND NOTIFY ARCHITECT OF EXISTING NIGHT DEPOSIT ROUGH OPENING DIMENSIONS AND HEIGHT ABOVE FINISH FLOOR. GC TO INCLUDE IN BID REPLACEMENT OF MATCHING PANEL TO ACCOMODATE NEW NIGHT DEPOSIT. ND 11"4 1/2"1'-0" 5'- 0 1 / 2 " FRAMED ARTWORK BY BMO VENDOR 1'- 6 " 2'- 0 " EQ EQ EQ EQ RB-1 PT-1 GLASS FILM; REFER TO DETAILS ON A-601 AND FINISH SCHEDULE, TYPICAL OPEN TO BEYOND TEMPERED SAFETY GLASS, TYP. PT-5 1'- 6 " 13'-5" RB-1 FRAMED ARTWORK BY BMO VENDOR FRAMED ARTWORK BY BMO VENDOR 3' - 6 " T Y P 12'-3 1/2" TO CENTERLINE OF FRAME 8'-0" DSH-75 1'- 6 " (2) DATA DROP, (1) GANG BOX DEEP DUPLEX OUTLET. PROVIDE PULL STRING IN ALL CONDUIT. COORDINATE WITH OWNER'S AV DRAWINGS. VW-6 HE I G H T P E R V E N D O R A V D R A W I N G S CO O R D I N A T E D E V I C E M O U N T I N G 7'-6 1/2"8'-2 1/2" AVC A-500 5_________________ 5"5" EXTRON KEYPAD. CONFIRM LOCATION AND ELECTRICAL REQUIREMENTS WITH VENDOR A/V DRAWINGS RB-1 TO H I G H E S T O P E R A B L E P A R T 4'- 0 " CUSTOM GRAPHIC BY SIGN VENDOR OVER LEVEL 5 PAINTED FINISH BY GC RB-1 PT-4 EQ EQ S-7 NOTE:REFER TO MANUFACTURER'S CUT SHEETS FOR INSTALLATION HEIGHT OP E R A B L E P A R T 4' - 0 " M A X . T O T H E H I G H E S T CG THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 2 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 INTERIOR ELEVATIONS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 02/02/24 222702550 A-203 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALESCALE 1/2" = 1'-0"COAT CLOSET 111 - NORTH 2SCALE 1/2" = 1'-0"CORRIDOR 116 - HI-LOW DRINKING FOUNTAIN 3 SCALE 1/2" = 1'-0"ATM / LAN ROOM 105 - CAGE SYSTEM 4SCALE 1/2" = 1'-0"ATM / LAN ROOM 105 - NORTH 5 SCALE 1/2" = 1'-0"WORK ROOM - NIGHT DEPOSIT 6 1/2" = 1'-0"LOUNGE 2 103 - NORTH 71/2" = 1'-0"CORRIDOR 116 - SOUTH 8 SCALE SCALE 1/2" = 1'-0"CONFERENCE ROOM 109 - EAST 9 SCALE 1/2" = 1'-0"BANKING HALL 101 - BOTTLE FILLING STATION 1 SCALESCALE 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 2 PLAN CHECK #3 SS DR 2024/11/12 2 2 ALLL 10/28/2024 EXISTING SIDEWALK ATM WITH FACTORY-INSTALLED COLLAR, PROVIDED AND INSTALLED BY BMO VENDOR. NOTES: • HIGHEST OPERABLE PART OF ATM TO BE 48" A.F.F. GC TO CONFIRM ALL MEASUREMENTS TO ENSURE REACH REQUIREMENTS ARE MET. • GC TO CONFIRM ALL CUTOUT DIMENSIONS WITH ATM VENDOR PRIOR TO PURCHASE, INSTALLATION, OR ALTERATION OF ANY AND ALL MATERIALS. ATM DIMENSIONS BASED ON: NCR 6684 5 HIGH / OPEN COLLAR 5" SLEEVE / 19" TOUCHSCREEN NO CASH CAMERA EXISTING CONCRETE CURB OR PROVIDE CEN-CERTIFIED PLINTH ANCHORED TO SLAB BELOW. BOLT ATM TO PLINTH PER ATM MFR'S INSTRUCTIONS. SEE STRUCTURAL DRAWINGS FOR SEISMIC ANCHORAGE DETAILS. ATM SURROUND RELOCATED FROM EXISTING BRANCH BY BMO VENDOR SPRAY INSULATION, BACKER ROD, AND SEALANT AT GAP BETWEEN ATM AND WALL, TYP. CONTINUOUS SEALANT AT BUILDING FACE AND ATM TO ANCHOR ATM SURROUND, TYP. J-BEAD, TYP. AT EXPOSED EDGES OF GYP. BD. DE M O +/ - 1 1 / 2 " EX I S T I N G R O U G H O P E N I N G V I F 2'- 3 7 / 8 " EX I S T I N G V I F 2'- 7 5 / 8 " EXISTING EXTERIOR FINISH, PROTECT IN PLACE. EXISTING EXTERIOR WALL TO REMAIN. RED DASH OUTLINES PORTION OF EXISTING WALL TO BE REMOVED. EXISTING CONCRETE SLAB OP E NI N G P E R M F R . 2' - 5 1 / 4 " EXISTING ROUGH OPENING FOR THRU-WALL ATM. GC TO REMOVE EXISTING PLYWOOD AND PROVIDE ACTUAL ROUGH DIMENSIONS TO ARCHITECT. EXISTING SIDEWALK UNITIZED SAFE BASE PROVIDED BY BMO VENDOR. SEE STRUCTURAL DRAWINGS FOR SEISMIC ANCHORAGE DETAILS. SPRAY INSULATION, BACKER ROD, AND SEALANT AT GAP BETWEEN ATM AND WALL, TYP. EXISTING STOREFRONT FILL PANEL, PROTECT IN PLACE. EXISTING EXTERIOR WALL TO REMAIN. NOTES: • HIGHEST OPERABLE PART OF NIGHT DROP TO BE 48" A.F.F. GC TO CONFIRM ALL MEASUREMENTS TO ENSURE REACH REQURIEMENTS ARE MET. • GC TO CONFIRM ALL CUTOUT DIMENSIONS WITH VENDOR PRIOR TO PURCHASE, INTALLATION, OR ALTERATION OF ANY AND ALL MATERIALS. NIGHT DROP DIMENSIONS BASED ON: 30903 TL-30 AHD AND RECEIVING SAFE WITH SEUROMATIC AFTER HOURS DEPOSITORY WALK-UP. 6" EXISTING VERTICAL MULLION TO REMAIN, TYP. SPRAY INSULATION, BACKER ROD, AND SEALANT AT GAP BETWEEN ATM AND WALL, TYP. EX I S T I N G O P E N I N G 2' - 9 1 / 2 " EX I S T I N G O P E N I N G 2'- 5 1 / 2 " IN F I L L 6 1 / 2 " IN F I L L 1 3 / 4 " EXISTING STOREFRONT FILL PANEL, TYP. BLOCKING AS REQUIRED, TYP. SI L L PE R M F R . 2' - 7 " OP E NI N G P E R M F R . 2'- 1 1 / 4 " J-BEAD, TYP. AT EXPOSED EDGES OF GYP. BD. EXISTING CONCRETE SLAB EXISTING ROUGH OPENING FOR THRU-WALL ATM. GC TO REMOVE EXISTING PLYWOOD AND PROVIDE ACTUAL ROUGH DIMENSIONS TO ARCHITECT. A-300 2_________________A-300 3_________________ T.O. CURB 0' - 0" B.O. SOFFIT ± 11' - 9" LINE OF MODIFIED OPENING THRU EXTERIOR WALL. REFER TO SECTION FOR EXTENT OF INFILL. EXISTING STOREFRONT FILL PANEL, PROTECT IN PLACE. EXISTING STOREFRONT, PROTECT IN PLACE. EXISTING STONE VEENER WALL FINISH, PROTECT IN PLACE. TYPICAL ALL ADJACENT SURFACES. B. O . OP E N I N G 2'- 5 1 / 2 " V I F OP E NI N G 2'- 9 1 / 2 " V I F 3/4" OPENING 1'-11"3/4" B. O . O P E N I N G 2'- 7 3 / 4 " V I F OP E N I N G 2' - 4 " V I F 1 3/4" OPENING 2'-0 3/4"2 1/2" NOTE: EXISTING ROUGH OPENINGS TO BE VERIFIED IN FIELD. NEW NIGHT DROP PROVIDED AND INSTALLED BY BMO VENDOR NEW EXTERIOR WALL PACK, CENTERED OVER ATM. 9'- 0 " HIGHEST OPERABLE PART 10" - 24" FROM PARALLEL APPROACH CLEARANCE AREA 1 HE I G HT O P E R AB L E P A RT S 3' - 1 0 " M A X . R E A C H EXISTING STUCCO WALL FINISH, PROTECT IN PLACE. TYPICAL ALL ADJACENT SURFACES. MILLWORK ATM SURROUD RELOCATED FROM EXISTING BRANCH BY BMO VENDOR. ATM WITH FACTORY INSTALLED COLLAR. PROVIDED BY BMO AND INSTALLED BY BMO VENDOR. 1 HIGHEST OPERABLE PART IS 10" MAX FROM PARALLEL APPROACH CLEARANCE AREA OP E R A B L E P A R T S 4'- 0 " M A X R E A C H 1 1 NOTES: 1. G.C. SHALL VERIFY ALL ATM DIMENSIONS WITH FINAL BANK APPROVED MANUFACTURERS DRAWINGS BEFORE CONSTRUCTION. POINT OF SALE DEVICES [11B-220.2]: 1. ALL DEVICES AT EACH LOCATION SHALL COMPLY WITH OPERABLE PARTS PER 11B-707.3, DISPLAY SCREEN CHARACTERS PER 11B-707.7.2, AND POINT OF SALE DEVICES PER 11B-707.9. 2. CHARACTERS DISPLAYED ON THE SCREEN SHALL BE IN A SANS SERIF FONT. CHARACTERS SHALL BE 3/16 INCH HIGH MINIMUM BASED ON THE UPPERCASE LETTER "I". CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. 3. IF A VIDEO TOUCH SCREEN OR ANY OTHER NON TACTILE PAD IS USED, A TACTILELY DISCERNIBLE NUMERICAL KEYPAD SIMILAR TO A TELEPHONE KEYPAD COMPLYING WITH 11B-707.9.1.1 SHALL BE PROVIDED. SCOPE (11B-220.1): WHERE AUTOMATIC TELLER MACHINES OR SELF-SERVICE FARE VENDING, COLLECTION, OR ADJUSTMENT MACHINES ARE PROVIDED THEY SHALL COMPLY. WHERE BINS ARE POVIDED FOR ENVELOPES, WASTE PAPER, OR OTHER PURPOSES, AT LEAST ONE OF EACH TYPE SHALL COMPLY WITH 11B-811. WHERE ONE ATM IS PROVIED: SHALL COMPLY WITH CBC ACCESSIBILITY SCOPE ITEMS 1-13. WHERE TWO ATM'S ARE PROVIDED: ONE SHALL COMPLY WITH CBC ACCESSIBILITY SCOPE ITEMS 1-13. AND ONE SHALL COMPLY WITH CBC ACCESSIBILITY SCOPE ITEMS 1, 3-10, 12, 13. WHERE THREE OR MORE ATM'S ARE PROVIDED: AT LEAST 50% SHALL COMPLY WITH CBC ACCESSIBILITY SCOPE ITEMS 1-13. THE REST SHALL COMPLY WITH CBC ACCESSIBILITY SCOPE ITEMS 1, 3-10, 12, 13. WHERE DRIVE UP ATM'S ARE PROVIDED: SHALL COMPLY WITH CBC ACCESSIBILITY SCOPE ITEMS 4-10 AND 12. CBC ACCESSIBILITY SCOPE: 1. 11B-402 ACCESSIBLE ROUTES 2. 11B-707.2 CLEAR FLOOR OR GROUND SPACE 3. 11B-309/11B-707.3 OPERABLE PARTS 4. 11B-707.4 PRIVACY 5. 11B-707.5 SPEACH OUTPUT 6. 11B-707.5.1 USER CONTROL 7. 11B-707-5.2 RECEIPTS 8. 11B-707.6.1 INPUT CONTROLS 9. 11B-707-6.2 NUMERIC KEYS 10. 11B-707.6.3 FUNCTION KEYS 11. 11B-707.7.1 DISPLAY SCREEN VISIBILITY 12. 11B-707.7.2 DISPLAY SCREEN CHARACTERS 13. 11B-707.8 BRAILLE INSTRUCTIONS NOTE: G.C. TO COORDINATE WITH BMO ATM VENDOR FOR COMPLIANCE WITH CMC ACCESSIBILITY SCOPE 1-13 NOTED ABOVE. ATM ACCESSIBILITY NOTES THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 ATM / NIGHT DROP ELEVATION & DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-300 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1 1/2" = 1'-0"SECTION AT THRU-WALL ATM / SURROUND 21 1/2" = 1'-0"SECTION AT THRU-STOREFRONT NIGHT DEPOSIT 3 SCALESCALE 3/4" = 1'-0"WALK-UP ATM/NIGHT DROP - ELEVATION 1 SCALE 1 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 LL 10/28/2024 A-400 11 A-4006 A-202 5 10 13 12 6 7 8 A-4002 4 3 5 8 7 9 110 STAFF ROOM 115 JANITOR CLOSET 114 UNIVERSAL RR 113 RESTROOM M110-01 MS-1 MS-2 EXISTING MOP HOLDER (RELOCATED) F.D. TSC WC-4 GB TTDSND GB MIR F.D. WC-4GBGB TTD TSC CTD F.D. MIR 111 KDW S-2S-1 MTD KCM KMW 115 113114 110 111 COAT CLOSET A-2032 M111-01 LOC TYP. VB-3 SD CTD EXISTING SINK AND FAUCET PARTIAL HEIGHTED FURRING TO T.O. WALL TILE, SEE ELEVATION KFR L1 L2 SND SSH A-203 3 CHCH SD 111 KCM S-1 DM-1 WT-4 PT-1 PL-6 PT-9 PL-5 ES-1 PL-4 110 1' - 6 " T Y P . 4'-6" AC C E S S I B L E R E A C H A B L E R A N G E 2'- 9 " MI N . 1'- 3 " RB-1 4'- 0 " 20" 20" (20") (20") 20" (20") 20" (43") KFR A-505 4_________________ A-504 11_________________A-504 9_________________ A-504 14_________________ A-505 2 3'- 4 " 3'-7" M110-01 1'- 6 " 1"2'-8"1"2 EQUAL 3" 6'-6 1/2" KMWMTDS-1KCM KDW PL-6 DM-1 OPEN TO BEYOND PL-5 PL-4 PL-4 MICROWAVE TRIM KIT WT-4 S-2 4" 4'- 4 " ES-1 PT-1 AC C E S S I B L E R E A C H A B L E R A N G E 2'- 9 " MI N . 1'- 3 " 4'- 0 " 31" 31" (31") 24"27" 27" (27") (27") (30") A-505 3_________________ A-504 14_________________ A-504 9_________________A-504 13_________________ A-504 8_________________A-504 17_________________ 3'-7" CL OUTLET 7'-4" CL OUTLET 3' - 2 " T Y P 3'-9 1/2" M110-01 1"2'-3"1"2'-0"3'-0"2'-1"2'-8"3" 12'-5" RB-1 VB-3 PT-1 2'- 6 " 1'- 6 " PR20X GF-1A 2'-0" 4'-8" TEMPERED SAFETY GLASS, TYP. PT-9 RB-1 PT-9 LOC 6'- 6 " RB-1 1'- 6 " 5'-9" NOTE: LOCKER CONTROLS SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST HO O K S W I T H I N 1 5 " - 4 8 " R E A C H H E I G H T CO N T R O L S A N D I N T E R I O R C O A T 1'- 3 " 2'- 9 " LOCKER CONTROLS AND INTERIOR COAT HOOKS, TYP.ADJUSTABLE SHELF 15" MIN. 6' - 3 " TSC GBGB TTD WC-4 INSTALL FULL TILE AT TOP ROW WT-2 PT-1 TB-1 A-501 8_________________ SND A-501 10_________________ INSTALL FULL TILE AT TOP ROW TB-1 PT-1 WT-2 MIR 1'-6" WC-4 TTD GBGB A-501 8_________________ EXISTING SINK AND FAUCET SND GC TO BOX OUT PLUMBING TO MATCH ADJACENT RESTROOM A-501 10_________________M113-01 A-504 7_________________SIM. SD PT-1 TB-1 MIR A-501 7_________________ M113-01 2'-0" 3'- 4 " 7"TSC PT-1 TB-1 A-501 7_________________ 113 CHCH TB-1 PT-1 WT-2 INSTALL FULL TILE AT TOP ROW GBGB WC-4 SND TTD TSC A-501 8_________________ A-501 10_________________ 6'- 3 " ALIGN MIR INSTALL FULL TILE AT TOP ROW PL-6 M114-01 SS-3 TB-1 TTDSNDWC-4 GBGB PT-1 1'-5" WT-2 A-501 8_________________ SD A-504 7_________________ 2'-3 1/2"3 3/4" A-501 10_________________ A-501 7_________________ PT-1 MIR PL-6 TB-1 M114-01 CTD 2'-0" 1'-4" TSC PT-1 A-501 7_________________ CH TB-1 114 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 2 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 ENLARGED RESTROOM / STAFF ROOM PLANS AND ELEVATIONS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-400 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 TRUE NORTH 1/2" = 1'-0"ENLARGED RESTROOM, JANITOR CLOSET, AND STAFF ROOM PLAN 1SCALE 1/2" = 1'-0"STAFF ROOM 110 - NORTH 21/2" = 1'-0"STAFF ROOM 110 - EAST 3 1/2" = 1'-0"STAFF ROOM 110 - SOUTH 41/2" = 1'-0"STAFF ROOM 110 - WEST 5 1/2" = 1'-0"RESTROOM 113 - NORTH 61/2" = 1'-0"RESTROOM 113 - EAST 71/2" = 1'-0"RESTROOM 113 - SOUTH 81/2" = 1'-0"RESTROOM 113 - WEST 9 1/2" = 1'-0"UNIVERSAL RESTROOM 114 - NORTH 101/2" = 1'-0"UNIVERSAL RESTROOM 114 - EAST 111/2" = 1'-0"UNIVERSAL RESTROOM 114 - SOUTH 121/2" = 1'-0"UNIVERSAL RESTROOM 114 - WEST 13 SCALESCALE SCALE SCALE SCALESCALESCALESCALE SCALE SCALE SCALE SCALE GENERAL NOTES: 1. REFER TO SCHEDULES ON SHEET A-606. 2. DIMENSIONS ARE FROM FINISH FACE TO FINISH FACE OF WALL 3. ALL OUTLET COVERS TO BE STAINLESS STEEL IN STAFF ROOM, ONLY AT TILE WALLS. NOTES: 1. REFER TO SHEET G-101 FOR TYPICAL RESTROOM ACCESSIBLE MOUNTING HEIGHTS AND DIMENSIONS. 2. REFER TO SHEET A-606 FOR RESTROOM ACCESSORIES AND PLUMBING FIXTURE SCHEDULE. NOTES: 1. REFER TO SHEET G-101 FOR TYPICAL RESTROOM ACCESSIBLE MOUNTING HEIGHTS AND DIMENSIONS. 2. REFER TO SHEET A-606 FOR RESTROOM ACCESSORIES AND PLUMBING FIXTURE SCHEDULE. NOTES: 1. REFER TO SHEET G-101 FOR TYPICAL RESTROOM ACCESSIBLE MOUNTING HEIGHTS AND DIMENSIONS. 2. REFER TO SHEET A-606 FOR RESTROOM ACCESSORIES AND PLUMBING FIXTURE SCHEDULE. NOTES: 1. REFER TO SHEET G-101 FOR TYPICAL RESTROOM ACCESSIBLE MOUNTING HEIGHTS AND DIMENSIONS. 2. REFER TO SHEET A-606 FOR RESTROOM ACCESSORIES AND PLUMBING FIXTURE SCHEDULE. NOTES: 1. REFER TO SHEET G-101 FOR TYPICAL RESTROOM ACCESSIBLE MOUNTING HEIGHTS AND DIMENSIONS. 2. REFER TO SHEET A-606 FOR RESTROOM ACCESSORIES AND PLUMBING FIXTURE SCHEDULE. NOTES: 1. REFER TO SHEET G-101 FOR TYPICAL RESTROOM ACCESSIBLE MOUNTING HEIGHTS AND DIMENSIONS. 2. REFER TO SHEET A-606 FOR RESTROOM ACCESSORIES AND PLUMBING FIXTURE SCHEDULE. NOTES: 1. REFER TO SHEET G-101 FOR TYPICAL RESTROOM ACCESSIBLE MOUNTING HEIGHTS AND DIMENSIONS. 2. REFER TO SHEET A-606 FOR RESTROOM ACCESSORIES AND PLUMBING FIXTURE SCHEDULE. NOTES: 1. REFER TO SHEET G-101 FOR TYPICAL RESTROOM ACCESSIBLE MOUNTING HEIGHTS AND DIMENSIONS. 2. REFER TO SHEET A-606 FOR RESTROOM ACCESSORIES AND PLUMBING FIXTURE SCHEDULE. 50% OF CABINET STORAGE FRONTAGE MUST BE WITHIN ACCESSIBLE REACH RANGE: SHELVING FRONTAGE WITHIN REACH RANGE: 140" SHELVING FRONTAGE BEYOND REACH RANGE: (115") 50% OF CABINET STORAGE FRONTAGE MUST BE WITHIN ACCESSIBLE REACH RANGE: SHELVING FRONTAGE WITHIN REACH RANGE: 80" SHELVING FRONTAGE BEYOND REACH RANGE: 103" ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 2 PLAN CHECK #3 SS DR 2024/11/12 1 2 2 ALLL 10/28/2024 4 2 A-401 3 A-401 4 A-203 GENERAL NOTES -ENLARGED LAN ROOM PLAN 1. ALL CONDUITS TO BE RECESSED IN WALL. NO SURFACE MOUNTED CONDUITS. 2. ENSURE THAT NO SPRINKLER HEADS ARE LOCATED DIRECTLY ABOVE IT EQUIPMENT. 3. GC TO COORDINATE WITH BMO IT AND BMO VENDORS FOR ALL LAN ROOM REQUIREMENTS. 4. GC TO PROVIDE AND INSTALL SERVER RACKS. REFER TO SERVER RACK SPECS AND SOURCING INFORMATION ON THIS SHEET. 5. N.B. FOR EACH BELDEN CABINET, THE TWO 20A PDUS ARE NOT INCLUDED AND MUST BE ORDERED SEPARATELY. 6. REFER TO BMO TELECOM WORKSPACE STANDARDS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. BELDEN -BMO STANDARD CABINET -US WESCO INTERNATIONAL: CONTACT: SEAN ROWSOME EMAIL: SEAN.ROWSOME@WESCODIST.COM • TO BE ORDERED THROUGH WESCO PER BMO - WESCO/BELDEN MSA. • N.B. FOR EACH BELDEN CABINET, THE TWO 20A PDUS ARE NOT INCLUDED AND MUST BE ORDERED SEPERATELY. 9BG2-141009 BELDEN CANADA: CONTACT: SERGIO PODDA EMAIL: SERGIO.PODDA@BELDEN.COM THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 ENLARGED LAN ROOM PLANS AND DETAILS BMO BANK N.A. TENANT IMPROVEMENT BMO DPBMO 2024/08/16 222702550 A-401 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 3/4" = 1'-0"LAN ROOM - CABINET ELEVATION FRONT 3 3/4" = 1'-0"LAN ROOM - CABINET ELEVATION REAR 4 3/4" = 1'-0"LAN ROOM - IDF LAYOUT 2 SCALE 3/8" = 1'-0"ENLARGED LAN ROOM 1SCALESCALE SCALE ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 SCREW ATTACHMENTS: #8 x 1" WAFER HEAD SCREW PLACED AT 1/2" FROM PLATE EDGE 3/4" x 5 1/8" x STUD SPACING FIRE- TREATED PLYWOOD, TYP. DANBACK FLEXIBLE WOOD BACKING PLATE D16F OR APPROVED EQUAL USE FOR PANTRY SHELVING, LIGHT-DUTY WALL HUNG MILLWORK OR STEEL CABINETS, LIGHT WEIGHT SHELVING, TV MONITORS, AND SCREENS. USE FOR GRAB BARS, HANDRAILS, BOOKSHELVES, OVERHEAD FURNITURE, PLASMA SCREENS NOT EXCEEDING 100 LBS, STORAGE AREA SHELVING, WALL SYSTEMS AND ASSEMBLIES OTHER THAN ARCHITECTURAL WOODWORK, AND STONE PANELING. SCREW ATTACHMENTS: #8 x 1" WAFER HEAD SCREW PLACED AT 1/2" FROM PLATE EDGE 3/4" x 6" x STUD SPACING FIRE-TREATED PLYWOOD, TYP. LOCATE AS REQUIRED BY APPROVED SHOP DRAWINGS AND ARCHITECT'S OR MANUFACTURER'S WRITTEN INSTRUCTIONS. FRAMED PARTITION, SEE PARTITION TYPE SCHEDULE FOR STUD SIZE AND SPACING 18 GA. x 4" CONTINUOUS FLAT GALV. STEEL STRAP, SEE WOOD BACKING NOTE FOR LOCATION. FRAMED PARTITION, SEE PARTITION TYPE SCHEDULE FOR STUD SIZE AND SPACING SCREW ATTACHMENTS: TBD BY GC. 18 GA STEEL STRAP, MIN. 3" WIDTH. USE FOR PAPER TOWEL DISPENSERS, TOWEL BARS, TOILET PAPER HOLDERS, ARTWORK, DISPLAY SYSTEMS, WRITING SURFACE BOARDS, DISPLAY CASES, AND MIRRORS. FRAMED PARTITION, SEE PARTITION TYPE SCHEDULE FOR STUD SIZE AND SPACING SCREW ATTACHMENTS: TBD BY GC. CONTINUOUS 18 GA STEEL TRACK, CLIP FLANGES AT EACH STUD USE FOR PANTRY SHELVING, LIGHT-DUTY WALL HUNG MILLWORK OR STEEL CABINETS, LIGHT WEIGHT SHELVING, TV MONITORS, AND SCREENS. FRAMED PARTITION, SEE PARTITION TYPE SCHEDULE FOR STUD SIZE AND SPACING SOUND ATTENUATION INSULATION WHERE SCHEDULED, NOM. THICKNESS TO MATCH FRAMING DEPTH. SCHEDULED CEILING, SEE RCP LINE OF FLOOR STRUCTURE 3-5/8" METAL STUD INTERIOR PARTITION NON-RATED, NO INSULATIONPF1 3-5/8" METAL STUD INTERIOR PARTITION WITH ACOUSTIC BATT INSULATIONPF2 3-5/8" METAL STUD INTERIOR PARTITIONPF3 ONE LAYER TYPE 'X' GYP. BD., EXTEND FROM FLOOR SLAB TO STRUCTURE, TAPED AND SPACKLED. TYP. BOTH SIDES. SEE FINISH PLAN. METAL STUDS @ 16" O.C. SECURED TO SLAB ABOVE AND BRACED AS REQ'D FLOOR SLAB OR STRUCTURE ABOVE CONTINUOUS ACOUSTICAL SEALANT OR FIRE STOP, TYP. BOTH SIDES, TYP. TOP AND BOTTOM OF WALL. SLIP-TYPE TRACK, FASTENED TO STRUCTURE FOR BUILDING DEFLECTION MAX. 1 3/8" EITHER DIRECTION. LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SCHEDULED BASE, WHERE PRESENT. SEE FINISH PLAN AND SCHEDULE. LINE OF FLOOR STRUCTURE ONE LAYER TYPE 'X' GYP. BD., EXTEND FROM FLOOR SLAB TO STRUCTURE, TAPED AND SPACKLED. TYP. BOTH SIDES. SEE FINISH PLAN. FLOOR SLAB OR STRUCTURE ABOVE LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SCHEDULED BASE, WHERE PRESENT. SEE FINISH PLAN AND SCHEDULE. LATERAL BRACING AS REQUIRED, MIN. 2-1/2" X 20 GA METAL STUD @ 48" MIN. OC. 6" M I N . SCHEDULED CEILING, SEE RCP METAL STUDS @ 16" O.C. SECURED TO SLAB ABOVE AND BRACED AS REQ'D 3-5/8" METAL STUD INTERIOR PARTITIONP1 3-5/8" METAL STUD INTERIOR PARTITIONP2 SOUND ATTENUATION INSULATION WHERE SCHEDULED, NOM. THICKNESS TO MATCH FRAMING DEPTH. LINE OF FLOOR STRUCTURE ONE LAYER TYPE 'X' GYP. BD., EXTEND FROM FLOOR SLAB TO STRUCTURE, TAPED AND SPACKLED. SEE FINISH PLAN. FLOOR SLAB OR STRUCTURE ABOVE LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SCHEDULED BASE, WHERE PRESENT. SEE FINISH PLAN AND SCHEDULE. LATERAL BRACING AS REQUIRED, MIN. 2-1/2" X 20 GA METAL STUD @ 48" MIN. OC. SCHEDULED CEILING, SEE RCP METAL STUDS @ 16" O.C. SECURED TO SLAB ABOVE AND BRACED AS REQ'D 3-5/8" METAL STUD INTERIOR FURRING PARTITIONPPF1 3-5/8" METAL STUD INTERIOR FURRING PARTITIONPPF2 PS1 3-5/8" METAL STUD INTERIOR PARTITION W/ SECURITY MESH PS2 3-5/8" METAL STUD INTERIOR PARTITION W/ SECURITY MESH 1 5/8" METAL STUD INTERIOR FURRING PARTITIONPPF3 SOUND ATTENUATION INSULATION WHERE SCHEDULED, NOM. THICKNESS TO MATCH FRAMING DEPTH. SCHEDULED CEILING, SEE RCP LINE OF FLOOR STRUCTURE ONE LAYER TYPE 'X' GYP. BD., EXTEND FROM FLOOR SLAB TO STRUCTURE, TAPED AND SPACKLED. TYP. BOTH SIDES. SEE FINISH PLAN. METAL STUDS @ 16" O.C. SECURED TO SLAB ABOVE AND BRACED AS REQ'D FLOOR SLAB OR STRUCTURE ABOVE CONTINUOUS ACOUSTICAL SEALANT OR FIRE STOP, TYP. BOTH SIDES, TYP. TOP AND BTM OF WALL. SLIP-TYPE TRACK, FASTENED TO STRUCTURE FOR BUILDING DEFLECTION MAX. 1 3/8" EITHER DIRECTION. LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SCHEDULED BASE, WHERE PRESENT. SEE FINISH PLAN AND SCHEDULE. SECURITY MESH: CLARK DIETRICH BM 15-9 BARRIER MESH OR APPROVED EQUAL, 1.05 LBS / SF, ATTACH MESH TO STUDS USING MFR'S PROPRIETARY FASTENERS. FOLLOW ALL MFR'S FASTENING AND INSTALLATION INSTRUCTIONS. NOTE:INSTALL MESH ON BMO'S SIDE OF DEMISING WALLS, NOT ON OTHER TENANT'S SIDE. EXTEND FROM FLOOR SLAB TO STRUCTURE. NOTE:ALL STUD GAUGE AND MAX. HEIGHT TABLES ASSUME 1-5/8" FLANGE, LATERAL LOAD OF 5 PSF, AND ALLOWABLE DEFLECTION OF L/120. NON-RATED, NO INSULATION WITH ACOUSTIC BATT INSULATION NON-RATED, NO INSULATION WITH ACOUSTIC BATT INSULATION NON-RATED, NO INSULATION WITH ACOUSTIC BATT INSULATION NON-RATED, NO INSULATION SCHEDULED CEILING, SEE RCP LINE OF FLOOR STRUCTURE METAL STUDS @ 16" O.C. SECURED TO SLAB ABOVE AND BRACED AS REQ'D FLOOR SLAB OR STRUCTURE ABOVE CONTINUOUS ACOUSTICAL SEALANT OR FIRE STOP, TYP. BOTH SIDES, TYP. TOP AND BTM OF WALL. SLIP-TYPE TRACK, FASTENED TO STRUCTURE FOR BUILDING DEFLECTION MAX. 1 3/8" EITHER DIRECTION. LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SCHEDULED BASE, WHERE PRESENT. SEE FINISH PLAN AND SCHEDULE. 3-5/8" METAL STUD INTERIOR PARTITION W/ PLYWOODPB1 3-5/8" METAL STUD INTERIOR PARTITION W/ PLYWOODPB2 NON-RATED, NO INSULATION WITH ACOUSTIC BATT INSULATION P - PARTITION TO 6" ABOVE CEILING:PF - FULL HEIGHT PARTITION:PP - FURRING PARTITION TO 6" ABOVE CEILING:PB - FULL HEIGHT PARTITION WITH PLYWOOD BLOCKING: PLYWOOD BLOCKING: 3/4" FIRE-TREATED PLYWOOD, TYP., CONFIRM EXTENTS WITH WALL DETAILS. SHIM ABOVE AND BELOW AS REQUIRED TO MAINTAIN PLUMB FACE OF GYP. BD. SOUND ATTENUATION INSULATION WHERE SCHEDULED, NOM. THICKNESS TO MATCH FRAMING DEPTH. ONE LAYER TYPE 'X' GYP. BD., EXTEND FROM FLOOR SLAB TO STRUCTURE, TAPED AND SPACKLED. TYP. BOTH SIDES. SEE FINISH PLAN. PS - FULL HEIGHT PARTITION WITH SECURITY MESH: SOUND ATTENUATION INSULATION WHERE SCHEDULED, NOM. THICKNESS TO MATCH FRAMING DEPTH. TEKNION DEMOUNTABLE PARTITION BY FURNITURE VENDOR, SEE MFR DETAILS FOR DRYWALL CONNECTION AND REQUIRED TOLERANCES @DP1: MAINTAIN CLEAR OPENING FOR RETURN AIR TO PLENUM @DP2: EXTEND INSULATION AND GYP. BD. TO DECK. CORNER BEAD, TYP. BOTH SIDES 3 5/8" 16 GA METAL STUDS WITH 16 GA TOP AND BOTTOM TRACK 3-5/8" METAL STUD INTERIOR PARTITION AT DEMOUNTABLE PARTITION ACOUSTIC BATT INSULATION - WITH AIR GAP DP1 RC P SE E 6" SOUND ATTENUATION INSULATION WHERE SCHEDULED, NOM. THICKNESS TO MATCH FRAMING DEPTH. LINE OF FLOOR STRUCTURE ONE LAYER TYPE 'X' GYP. BD., EXTEND FROM FLOOR SLAB TO STRUCTURE, TAPED AND SPACKLED. TYP. BOTH SIDES. SEE FINISH PLAN. FLOOR SLAB OR STRUCTURE ABOVE LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SCHEDULED CEILING, SEE RCP METAL STUDS @ 16" O.C. SECURED TO SLAB ABOVE AND BRACED AS REQ'D 3-5/8" METAL STUD INTERIOR PARTITION AT DEMOUNTABLE PARTITION ACOUSTIC BATT INSULATION - TO DECK DP2 DP - DEMOUNTABLE PARTITION - BY OTHERS: SEE STOREFRONT MFR'S INSTRUCTIONS FOR INFORMATION ON REQUIRED FLOOR LEVELING AND SILL PREPARATION, TYP. BLACK ALUMINIUM STOREFRONT SYSTEM; GC TO FIELD VERIFY, EXTEND FROM FLOOR TO STRUCTURE ABOVE. SEE MFR'S INSTALLATION INSTRUCTIONS FOR FRAME COMPONENT SIZES AND ADDITIONAL INFORMATION. INSTALL PER MFR'S INSTRUCTIONS, TYP. 3/8" CLEAR TEMPERED SAFETY GLASS, TYP. THROUGHOUT STOREFRONT SYSTEM. LINE OF FLOOR STRUCTURE FLOOR SLAB OR STRUCTURE ABOVE LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SF2 SF - STOREFRONT PARTITION: VIF 4 1/2" AT SF-2 4-1/2" DEPTH STOREFRONT SYSTEM (VIF) TRIFAB® VERSAGLAZE® 450 FRAMING SYSTEM 2" SIGHTLINE TYPICAL 3-5/8" METAL STUD PARTIAL HEIGHT PARTITION NON-RATED, NO INSULATIONHP1 SE E E L E V A T I O N S METAL STUDS @ 16" O.C., FASTEN METAL STUD TO STEEL TUBING AS REQUIRED TO RESIST LATERAL LOADING. METAL TOP RUNNER EXISTING SLAB ON GRADE SCHEDULED P-LAM ON 1/2" SUBSTRATE, TYP. BOTH SIDES. SEE FINISH PLAN AND SCHEDULE. LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SCHEDULED BASE, WHERE PRESENT. SEE FINISH PLAN AND SCHEDULE. WOOD BLOCKING AS REQUIRED HP - HALF HEIGHT PARTITION: LINE OF 2" SQUARE TUBE BEYOND 2" x 2" x 3/16" SQUARE STRUCTURAL STEEL TUBING, TYP. ; REFER TO PARTITION PLAN 3 1/2" x 6" x 1/4" THICK BASE PLATE WELD TO COLUMN W/ 3/16" FILLET WELD ONE HOUR RATED - UL U419 LATERAL BRACING AS REQUIRED, MIN. 2-1/2" X 20 GA METAL STUD @ 48" MIN. OC. SOUND ATTENUATION INSULATION WHERE SCHEDULED, NOM. THICKNESS TO MATCH FRAMING DEPTH. LINE OF FLOOR STRUCTURE ONE LAYER TYPE 'X' GYP. BD., EXTEND FROM FLOOR SLAB TO STRUCTURE, TAPED AND SPACKLED. SEE FINISH PLAN. FLOOR SLAB OR STRUCTURE ABOVE LINE OF FINISHED FLOOR, SEE FINISH SCHEDULE. SCHEDULED BASE, WHERE PRESENT. SEE FINISH PLAN AND SCHEDULE. LATERAL BRACING AS REQUIRED, MIN. 2-1/2" X 20 GA METAL STUD @ 48" MIN. OC. SCHEDULED CEILING, SEE RCP METAL STUDS @ 16" O.C. SECURED TO SLAB ABOVE AND BRACED AS REQ'D 3-5/8" METAL STUD INTERIOR FURRING PARTITIONPP1 3-5/8" METAL STUD INTERIOR FURRING PARTITIONPP2 1 5/8" METAL STUD INTERIOR FURRING PARTITIONPP3 6" M I N . NON-RATED, NO INSULATION WITH ACOUSTIC BATT INSULATION NON-RATED, NO INSULATION PP - FURRING PARTITION TO 6" ABOVE CEILING: 3 5/8" METAL STUD INTERIOR FURRING PARTITIONPP4NON-RATED, NO INSULATION, GYPSUM BOARD TO CEILING. 6" METAL STUD INTERIOR FURRING PARTITION *SPECIFIC STUD PER STRUCTURAL DRAWINGSPPF4NON-RATED, NO INSULATION 6" METAL STUD INTERIOR FURRING PARTITIONPP5WITH ACOUSTIC BATT INSULATION 6" METAL STUD INTERIOR FURRING PARTITION *SPECIFIC STUD PER STRUCTURAL DRAWINGSPPF5WITH ACOUSTIC BATT INSULATION TEMPERED SAFETY GLASS (4) 1/4" DIA. X 2 1/2" NOMINAL EMBED. SIMPSON TITEN HD ANCHORS TO CONCRETE PARTIAL HEIGHT PARTITION - ONE POST PLAN EQ EQ WOOD BLOCKING AS REQUIRED 2" x 2" x 3/16" SQUARE STRUCTURAL STEEL TUBING AND PLATE, TYP. 6" 4 5/8" 3 1/2" x 6" x 1/4" THICK BASE PLATE WELD TO COLUMN W/ 3/16" FILLER WELD (4) 1/4" DIA. X 2 1/2" NOMINAL EMBED. SIMPSON TITEN HD ANCHORS TO CONCRETE PARTIAL HEIGHT PARTITION - TWO POST PLAN 2 1 / 4 " 3 3 / 4 " 3 3 / 4 " 2 1 / 4 " METAL STUDS @ 16" O.C., TYP. WOOD BLOCKING AS REQUIRED 2" x 2" x 3/16" SQUARE STRUCTURAL STEEL TUBING, TYP. WELD STEEL TUBING TO 1/4" THICK PLATE ANCHORED TO SUBFLOOR. TUBE SUPPORTS SPACED @ +/- 32" O.C., TYP. 2" x 2" x 3/16" SQUARE STRUCTURAL STEEL TUBING AND PLATE AT EACH END OF PARTIAL HEIGHT WALL, TYP.; MINIMUM TWO TUBES PER WALL SECTION, AND MAX 18" O.C. 4 3/4" SE E P L A N 3 1/2" x 6" x 1/4" THICK BASE PLATE WELD TO COLUMN W/ 3/16" FILLER WELD (4) 1/4" DIA. X 2 1/2" NOMINAL EMBED. SIMPSON TITEN HD ANCHORS TO CONCRETE METAL STUDS @ 16" O.C., TYP. SCHEDULED PARTITION, SEE FINISH PLAN AND SCHEDULE FOR ADDITIONAL INFORMATION LINE OF DEMOUNTABLE PARTITION BY BMO VENDOR, TYP. 2 1 / 4 " 3 3 / 4 " 4 3/4" SE E P L A N METAL STUDS @ 16" O.C., TYP. WOOD BLOCKING AS REQUIRED 2" x 2" x 3/16" SQUARE STRUCTURAL STEEL TUBING AND PLATE AT EACH END OF PARTIAL HEIGHT WALL, TYP.; MINIMUM TWO TUBES PER WALL SECTION, AND MAX 18" O.C. (4) 1/4" DIA. X 2 1/2" NOMINAL EMBED. SIMPSON TITEN HD ANCHORS TO CONCRETE 1" PARTIAL HEIGHT PARTITION - ONE POST PLAN 5/8" GYP. BOARD ALL SIDES OF POST, TYP. (2) METAL STUDS, NEST WITHIN RUNNERS (2) METAL RUNNERS, TYP. 5" 5" CORNER BEAD, TYP. LINE OF DEMOUNTABLE PARTITION BY BMO VENDOR, TYP. SEE PARTITION PLAN FOR QTY AND LOCATIONS OF PARTITIONS AT EACH COLUMN. SCHEDULED PARTITION, SEE FINISH PLAN AND SCHEDULE FOR ADDITIONAL INFORMATION LINE OF DEMOUNTABLE PARTITION BY BMO VENDOR, TYP. ALIGN 5" CORNER BEAD, TYP. MONITOR MOUNTING BRACKET, SEE VENDOR AV DRAWINGS FOR SIZE AND SPECIFICIATION. COORDINATE LOCATION OF POWER / DATA DEVICES WITH MOUNTING BRACKET CLEARANCE, ALL CABLING AND DEVICES TO BE CONCEALED BEHIND DISPLAY. SCHEDULED FLATSCREEN DISPLAY MONITOR, SEE AV DRAWINGS AND EQUIPMENT SCHEDULE SHEET A-605. MIN. 4' X 4' X 3/4" THICK PLYWOOD BLOCKING SECURED TO WALL FRAMING, COORDINATE WITH WEIGHT OF TV & BRACKET. BRACING TO SUPPORT 3X WEIGHT OF EQUIPMENT. SCHEDULED PARTITION NOTE:COORDINATE MONITOR MOUNTING HEIGHT AND ELECTRICAL REQUIREMENTS WITH VENDOR AV DRAWINGS. FIRE TREATED WOOD BLOCKING, TYP. SCHEDULED WALL, SEE PARTITION TYPE SCHEDULE. SEE PARTITION PLAN FOR LOCATIONS OF REAR FURRING WALLS WHERE APPLICABLE. METAL STUDS, SEE PARTITION TYPE SCHEDULE FOR SPACING AND THICKNESS REQUIREMENTS. LINE OF FINISHED FLOOR NEW RECESSED FIRE EXTINGUISHER CABINET, FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION. TAPE, SPACKLE, AND FINISH AS REQUIRED WITH CORNER BEADS. NOTE:GC TO COORDINATE SPACING OF FURRED WALLS TO ACCOMMODATE FIRE EXTINGUISHER CABINET, SEE PARTITION PLAN. HI G H E S T O P E R A B L E P A R T O F E X T I N G U I S H E R 4'- 0 " M A X . ADA COMPLIANT HARDWARE SPEC. SEE FEC FIRE TREATED WOOD BLOCKING WHERE REQUIRED FIRE EXTINGUISHER EXISTING GLAZING, AND ALL MULLIONS TO REMAIN, TYP. EM SEAL 1" QUIET JOINT FILLER - WHITE SEE PARTITION TYPE SCHEDULE FOR ALL WALL CONSTRUCTION INFORMATION, TYP. FO R W A L L L O C A T I O N SE E P A R T I T I O N P L A N CORNER BEAD, TYP. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 PARTITION TYPES AND GENERAL DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-500 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1 1/2" = 1'-0"TYP. IN-WALL BLOCKING 6 WALL STUD GAUGE, SPACING, AND MAX. HEIGHT STUD WIDTH STUD GAUGE STUD SPACING MAX. HEIGHT COMMENTS 1 5/8" 20 GA 16" O/C 12'-0" TYP. FURRING STUD UNLESS NOTED OTHERWISE 1 5/8" 18 GA 16" O/C 13'-1" 1 5/8" 16 GA 16" O/C 13'-11" 2 1/2" 20 GA 16" O/C 16'-8" 2 1/2" 18 GA 16" O/C 18'-1" 2 1/2" 16 GA 16" O/C 19'-4" 3 5/8" 20 GA 16" O/C 22'-2" TYP. WALL STUD UNLESS NOTED OTHERWISE 3 5/8" 18 GA 16" O/C 24'-1" 3 5/8" 16 GA 16" O/C 25'-10" 6" 20 GA 16" O/C 30'-3" 6" 18 GA 16" O/C 35'-9" 6" 16 GA 16" O/C 38'-4" 1 1/2" = 1'-0"PARTITION TYPES 1 SCALE SCALE SCALE 3" = 1'-0"COLUMN @ DEMOUNT. PARTITION 2 SCALE SCALE 1 1/2" = 1'-0"END WALL AT DEMOUNT. PARTITION 3 1 1/2" = 1'-0"TYP. SURFACE MOUNT MONITOR 5 SCALE 1 1/2" = 1'-0"TYP. FEC CABINET - SEMI-RECESSED 4 SCALE 1 1/2" = 1'-0"PLAN SECTION AT EXIST. MULLION 7 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 WALL FINISH AS SCHEDULED 1/4" SCHLUTER JOLLY ALUMINIUM TRANSITION STRIP SCHEDULED TILE AND MORTAR WALL FINISH AS SCHEDULED J-CAP; JC12 KOROSEAL KOROGARD ALUMINUM TRANSITION STRIP SCHEDULED WALLCOVERING JOINT COMPOUND CONCRETE SLAB SCHEDULED CARPET, PAD, AND ADHESIVE TRANSITIONS FRAME SYSTEM PER MANUFACTURER TO BE INSTALLED ON CENTER OF DOOR JAMB, WHERE APPLICABLE NOTE: FLOAT FLOORS AS REQUIRED TO CREATE LEVEL TRANSITIONS BETWEEN MATERIALS, TYP. UNO. SCHEDULED PEDIMAT SYSTEM CONCRETE SLAB SCHEDULED RESILIENT FLOORING, FLOAT FLOOR FOR SMOOTH AND EVEN FINISH, COORDINATE WITH MANUFACTURER. SCHEDULED CARPET, PAD, AND ADHESIVE 1/8" SCHLUTER SCHIENE ALUMINIUM TRANSITION STRIP NOTE: FLOAT FLOORS AS REQUIRED TO CREATE LEVEL TRANSITIONS BETWEEN MATERIALS, TYP. UNO. CONCRETE SLAB SCHEDULED TILE BASE, TYP. 1/8" SCHLUTER SCHEINE ALUMINIUM TRANSITION STRIP, TYP. SCHEDULED TILE AND MORTAR GROUT JOINT SE E F I N I S H S C H E D U L E SCHEDULED WALL FINISH, SEE FINISH PLAN AND ELEVATIONS. CONCRETE SLAB SCHEDULED WALL PAINT, SEE FINISH SCHEDULES AND ELEVATIONS. CONCRETE SLAB SCHEDULED VINYL BASE, TYP., ATTACH TO WALL WITH MFR'S RECOMMENDED ADHESIVE. SCHEDULED FLOORING, TYP. SE E F I N I S H S C H E D U L E CONCRETE SLAB SCHEDULED RESILIENT FLOORING, FLOAT FLOOR FOR SMOOTH AND EVEN FINISH, COORDINATE WITH MANUFACTURER. SCHEDULED TILE AND MORTAR 1/8" SCHLUTER SCHIENE ALUMINIUM TRANSITION STRIP NOTE: FLOAT FLOORS AS REQUIRED TO CREATE LEVEL TRANSITIONS BETWEEN MATERIALS, TYP. UNO. CONCRETE SLAB EXISTING EXTERIOR PAVEMENT TO REMAIN SCHEDULED ENTRY PEDIMAT SYSTEM EXISTING STOREFRONT DOOR TRANSITION FRAME SYSTEM PER MANUFACTURER TO BE INSTALLED ON CENTER OF DOOR JAMB, BUTT TO ACCESSIBLE DOOR THRESHOLD AT EXTERIOR DOOR CONCRETE SLAB SCHEDULED CARPET, PAD, AND ADHESIVE 1/8" SCHLUTER SCHIENE ALUMINIUM TRANSITION STRIP SCHEDULED TILE AND MORTAR GROUT JOINT NOTE: FLOAT FLOORS AS REQUIRED TO CREATE LEVEL TRANSITIONS BETWEEN MATERIALS, TYP. UNO. CONCRETE SLAB SCHEDULED WALL TILE, TYP. SCHEDULED TILE AND MORTAR GROUT JOINT SE E F I N I S H S C H E D U L E SCHEDULED WALL PAINT, SEE FINISH SCHEDULES AND ELEVATIONS. ALIGN SCHEDULED DOOR ROOM SIDE PUBLIC SIDE TYPE 'S2' MULLION, SEE SHEET A-500 FOR SPECIFICATION. SEE WINDOW / GLAZING TYPES FOR MULLION SIZES. 4 1 / 2 " LINE OF DOOR HEADER ABOVE, TYP. 3/8" CLEAR GLAZING, SEE WINDOW / GLAZING SCHEDULE. INSTALL PER STOREFRONT MFR'S INSTRUCTIONS. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 INTERIOR DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 11/08/23 222702550 A-501 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALESCALE 3" = 1'-0"TRANSITION - WALL TILE 83" = 1'-0"TRANSITION - WALLCOVERING 9 SCALE 3" = 1'-0"TRANSITION - PEDIMAT TO CPT 13" = 1'-0"TRANSITION - CPT TO LVT 3 3" = 1'-0"TYP. TILE WALL BASE 7 3" = 1'-0"TYP. VINYL WALL BASE - COVE 6 SCALESCALE 3" = 1'-0"TRANSITION - TILE TO LVT 4 SCALESCALESCALESCALESCALE 3" = 1'-0"TRANSITION - PEDIMAT TO EXT. 23" = 1'-0"TRANSITION - CPT TO TILE 5 3" = 1'-0"TYP. TILE WALL AND BASE 10 SCALE 3" = 1'-0"STOREFRONT - JAMB 11 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 45° 60° MAX. TYP. CROSS T-BAR RUNNER, SEE REFLECTED CEILING PLAN AND FINISH SCHEDULE FOR SPACING. 45° NO. 12 GA. WIRE (NO. 9 GA. WIRE IF FIXTURE WEIGHT EXCEEDS 56 LBS. AND IS PENDANT HUNG) FIXTURE SUPPORT WIRES AT OPPOSITE CORNERS OF LIGHT FIXTURES. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING CONTRACTOR. STRUCTURAL T-BAR RUNNER, SEE REFLECTED CEILING PLAN AND FINISH SCHEDULE FOR SPACING. SCHEDULED LIGHT FIXTURE 3/4 #6 SCREWS (4 QTY) OR MFR-PROVIDED RESTRAINTS NO. 12 GA. WIRE FASTENED TO STRUCTURE ABOVE AND WITHIN 3" OF ALL FOUR CORNERS OF LIGHT FIXTURE SPLAY WIRES AS SHOWN AND PROVIDE MIN. OF 3 WIRE TURNS EA. CONNECTION POINT. FIXTURE SUPPORT WIRES COMPASSO CLIP 8" HIGH FLAT WHITE COMPASSO TRIM 5/8" GYP. BD., SEE RCP AND FINISH SCHEDULE FOR FINISH INFORMATION. 12" MAX. STRUCTURAL T-BAR RUNNER, SEE REFLECTED CEILING PLAN AND FINISH SCHEDULE FOR SPACING. SEE RCP FOR HT. AFF. STRUCTURE ABOVE 3 5/8" 20GA METAL STUD BRACING TO STRUCTURE ABOVE SCHEDULED CEILING, SEE RCP MI N . 6" SEE RCP FOR HT. AFF. NEW RECESSED LIGHT FIXTURE WHERE PRESENT, SEE ENLARGED RCP AND LIGHT FIXTURE SCHEDULE. SEE PARTITION PLAN FOR WALL TYPES, TYP. 3 5/8" 20GA METAL STUD @ 16" O/C, TYP. 5/8" GYP. BD., TYP. CORNER BEAD, TYP. SEE RCP SEE RCP FOR HT. AFF. STRUCTURE ABOVE 3 5/8" 20GA METAL STUD BRACING TO STRUCTURE ABOVE SEE PARTITION PLAN FOR WALL TYPES, TYP. 5/8" GYP. BD., TYP. CORNER BEAD, TYP. SCHEDULED CEILING, SEE RCP MI N . 6" SEE RCP FOR HT. AFF. SEE ELEVATIONS FOR MILLWORK SECTION DETAILS BLOCKING AS REQUIRED, TYP. 3 5/8" 20GA METAL STUD @ 16" O/C, TYP. SEE RCP STRUCTURE ABOVE SEE RCP FOR HT. AFF. CORNER BEAD, TYP. 3 5/8" 20GA METAL STUD BRACING TO STRUCTURE ABOVE 3 5/8" 20GA METAL STUD @ 16" O/C, TYP. 5/8" GYP. BD., TYP. SCHEDULED CEILING, SEE RCP SEE RCP FOR HT. AFF. SCHEDULED CEILING, SEE RCP SEE RCP FOR HT. AFF. MI N . 6" MI N . 6" 5" SEE RCP FOR HT. AFF. STRUCTURE ABOVE 3 5/8" 20GA METAL STUD BRACING TO STRUCTURE ABOVE @ 32" O.C. MI N . 6" SCHEDULED CEILING, SEE RCP ALIGN EXISTING GYP CEILING TO REMAIN, TYP. STRUCTURE ABOVE 3 5/8" 20GA METAL STUD BRACING TO STRUCTURE ABOVE 3 5/8" 20GA METAL FRAMING @ 16" O/C MI N . 6" SCHEDULED CEILING, SEE RCP EXISTING PERIMETER ENCLOSURE, EXTERIOR SOFFIT, GLAZING, AND MULLIONS TO REMAIN, TYP. VIF SEE RCP SEE RCP FOR HT. AFF SEE RCP FOR HT. AFF WINDOW SHADE WHERE INDICATED, SEE FINISH PLANS AND SCHEDULE STRUCTURE ABOVE SCHEDULED CEILING, SEE RCP EXISTING PERIMETER ENCLOSURE, EXTERIOR SOFFIT, GLAZING, AND MULLIONS TO REMAIN, TYP. SEE RCP FOR HT. AFF WINDOW SHADE WHERE INDICATED, SEE FINISH PLANS AND SCHEDULE STRUCTURE ABOVE 3 5/8" 20GA METAL STUD BRACING TO STRUCTURE ABOVE @ 32" O.C. SEE PARTITION PLAN FOR WALL TYPES, TYP.5/8" GYP. BD., TYP. CORNER BEAD, TYP. SEE ELEVATIONS FOR MILLWORK SECTION DETAILS BLOCKING AS REQUIRED, TYP. 3 5/8" 20GA METAL STUD @ 16" O/C, TYP. RCP SEE SEE RCP FOR HT. AFF. SEE RCP FOR HT. AFF. SEE RCP FOR HT. AFF. STRUCTURE ABOVE 3 5/8" 20GA METAL STUD BRACING TO STRUCTURE ABOVE @ 32" O.C. MI N . 6" SCHEDULED CEILING, SEE RCP EXISTING GYP CEILING TO REMAIN, TYP. SEE RCP FOR HT. AFF. STRUCTURE ABOVE SEE RCP FOR HT. AFF. CORNER BEAD, TYP. 3 5/8" 20GA METAL STUD BRACING TO STRUCTURE ABOVE 3 5/8" 20GA METAL STUD @ 16" O/C, TYP. 5/8" GYP. BD., TYP. SCHEDULED CEILING, SEE RCP SEE RCP FOR HT. AFF. SCHEDULED CEILING, SEE RCP SEE RCP FOR HT. AFF. MI N . 6" MI N . 6" RCP SEE THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 CEILING DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 09/22/23 222702550 A-502 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALESCALE SCALE SCALE SCALE SCALESCALE SCALE 1 1/2" = 1'-0"LIGHT FIXTURE DETAIL 11 1/2" = 1'-0"CORNER AT SUSPENDED GYP. BD. CEILING 21 1/2" = 1'-0"SECTION AT GYP. BD. SOFFIT 3 1 1/2" = 1'-0"SECTION AT GYP. BD. SOFFIT - ABOVE MILLWORK 7 1 1/2" = 1'-0"SECTION AT SINGLE STUD SOFFIT - ACT TO ACT 41 1/2" = 1'-0"EXISTING SOFFIT - FLUSH TO ACT 5 SCALE SCALE 1 1/2" = 1'-0"SECTION AT ACT TO GYP. BD. TRANSITION - BUILDING PERIMETER 10SCALESCALE 1 1/2" = 1'-0"SECTION ACT - BUILDING PERIMETER 11SCALE 1 1/2" = 1'-0"SECTION AT GYP. BD. SOFFIT - ABOVE MILLWORK 81 1/2" = 1'-0"EXISTING SOFFIT TO ACT 9 1 1/2" = 1'-0"SECTION AT DOUBLE STUD SOFFIT - ACT TO ACT 6 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 TRADE SIZE 1/2" 3'-10"4'-4" 3/4" 5'-2" 5'-7" 1" 6'-6" 7'-0" 1 1/4" 8'-6" 9'-0" 1 1/2" 9'-10" 10'-5" 2"- 13'-2" 1- #12 GA. BLACK SAFETY WIRE ATTACHED TO OPPOSING CORNERS ALONG FIXTURE'S DIAGONAL LIGHT FIXTURE OR AIR TERMINAL. (INSTALLATION SIMILAR FOR BOTH.) MAIN OR CROSS TEE. LIGHT FIXTURE OR MECHANICAL SERVICE ATTACHMENT 2- #12GA. BLACK SAFETY WIRE FROM DIAGONAL CORNERS TO STRUCTURE ABOVE. MAIN TEE. SUSPENDED CEILING TILE. CROSS TEE. #12 WIRE W/ 3 FULL TURNS WITHIN 3" OR LESS AT TOP AND BOTTOM ATTACHMENT POINTS. SPACE AT 4'-0" O.C. ALONG EACH MAIN RUNNER HILTI CEILING CLIP ANGLE W/ 5/16" EYELET. ATTACHED TO STRUCTURE ABOVE PER MANUFACTURER RECOMMENDATIONS #8 SELF TAPPING SCREWS TO ALL 4 CORNERS (TYP.) ATTACH SCREW TROUGH EITHER SIDE (OPTIONAL) OPTIONAL (LOOSE) 1.5" TOTAL TRAVEL CEILING GRID SYSTEM ATTACHMENT DETAIL AT ATTACHED WALL WITH PERIMETER SUPPORT WIRE DETAIL AT UNATTACHED WALL WITH PERIMETER SUPPORT WIRE BERC-2 CLEARANCE WALL INSTALLATION (UNATTACHED WALL) BERC-2 TIGHT WALL INSTALLATION (ATTACHED WALL) COMPRESSION POST AND SPLAY WIRE - IBC ASTM E-580 CATEGORY DEF 7/8" TEE PERIMETER HANGER WIRE SCREW ATTACHED (OPTIONAL) BERC-2 SEISMIC CLIP 7/8" 8" MAX. 7/8" X 7/8" WALL MOLDING BERC-2 SEISMIC CLIP 3/4" 3/4" 7/8" ATTACH SCREW TROUGH EITHER TOP FASTENER OPENING (OPTIONAL) 7/8"7/8" MAIN TEE 45° OR LESS 45° OR LESS 45° OR LESS 4 5° O R L E S S2" MAX. SEISMIC EXPANSION JOINT CLIP INSTALLED OPTION A MAIN TEE 4-WAY SEISMIC EXPANSION JOINT CLIP CROSS TEE SEISMIC EXPANSION JOINT CLIP INSTALLED OPTION B MAIN TEE TEE-FACE SLEEVE1"1" GAP BETWEEN FIELD CUT MAIN TEE CROSS TEE FASTENERS FASTENER 4-WAY SEISMIC EXPANSION JOINT CLIP ONE SIDE OF SPLICE CAP CRIMPED TO ALLOW MOVEMENT ONLY ON OPPOSITE END CROSS TEE ADJACENT SEISMIC EXPANSION JOINT- OPTION B CLIP INSTALLED MAIN TEE 4-WAY SEISMIC EXPANSION JOINT CLIP TEE-FACE SLEEVE ONE SIDE OF SPLICE CAP CRIMPED TO ALLOW MOVEMENT ONLY ON OPPOSITE END FASTENERS 1" 1" GAP BETWEEN FIELD CUT MAIN TEE BERC-2 TIGHT WALL INSTALLATION (ATTACHED WALL) ATTACH SCREW TROUGH EITHER SIDE (OPTIONAL) ATTACH SCREW TROUGH EITHER SIDE TOP FASTENER OPENING ALLOWABLE LENGTH EMT IMC OR RMC 8" MAX. TEE-FACE SLEEVE CROSS TEE ADJACENT SEISMIC EXPANSION JOINT- OPTION A CLIP INSTALLED ONE SIDE OF SPLICE CAP CRIMPED TO ALLOW MOVEMENT ONLY ON OPPOSITE END 4-WAY SEISMIC EXPANSION JOINT CLIP 1" TEE-FACE SLEEVE MAIN TEE FASTENERS CROSS TEE 1" GAP BETWEEN FIELD CUT MAIN TEE 2" MAX. COMPRESSION POST ENGINEERED TO FIT INSTALLATION. COMPRESSION POST SHALL MEET 2022 CBC AND ASCE 7-10 REQUIREMENTS VERTICAL HANGER WIRE ADJACENT TO POST COMPRESSION POST SPLAY WIRE SECURED TO SCTRUCTURE SPRING CLIP INSERTS IN HOLE IN PORST LATERAL FORCE BRACING WHERE SUBSTANTIATING DESIGN CALCULATIONS ARE NOT PROVIDED, HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR NO. 12 GAGE WIRES SECURED TO THE MAIN RUNNERS WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12 FEET ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FEET FROM EACH WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT IS NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 250 POUNDS OR TWO TIMES THE ACTUAL DESIGN LOAD. WHICH EVER IS GREATER. SPLAY WIRE BRACING Ref, ASTM E-580, SECTION 5.2.8.2 - 5.2.8.3 GENERAL NOTES: 1. CEILING AREA GREATER THAN 1,000 SF. MUST HAVE LATERAL FORCE BRACING BY MEANS OF WIRE OR RIGID BRACING 2. MAIN BEAMS & CROSS TEES MUST BE SUPPORTED WITHIN 8" OF EACH WALL W/ 12 GA. WIRE OR APPROVED WALL SUPPORT. 3. A STRUT IS TO BE ATTACHED TO THE SUSPENSION SYSTEM & TO THE STRUCTURE ABOVE AT EACH BRACING. 4. RIGID BRACING MAY BE USED INSTEAD OF DIAGONAL SPLAY WIRES. RIGID BRACING MUST LIMIT CEILING MOVEMENT TO LESS THAN 1/4" AT THE POINT OF ATTACHMENT (SPLAY WIRE BRACING IS CLUSTERS OF 4 WIRES ATTACHED TO THE MAIN BEAM WITHIN 2" OF A CROSS TEE INTERSECTION). 5. HORIZONTAL RESTRAINT POINTS ARE TO BE LOCATED NO MORE THAN 12' ON CENTER IN EACH DIRECTION, & THE FIRST POINT WITHIN 6'-0" OF EACH WALL 6. ATTACHMENT OF THE BRACING WIRES TO THE MAIN BEAM & THE STRUCTURE SHOULD SUPPORT THE GREATER OF 200 POUNDS OR THE ACTUAL DESIGN LOAD W/ A SAFE FACTOR OF 2. 7. HEAVY-DUTY GRID SYSTEM REQUIRED 8. GRID MUST BE ATTACHED TO 2 ADJACENT WALLS. USE BERC-2 CLIPS WITH SHEET METAL SCREW THROUGH THE HORIZONTAL SLOT OR FIXED HOLE IN THE CLIP. CLIPS INSTALLED ON OPPOSITE WALLS WHERE RUNNERS MUST NOT BE FIXED TO THE CLIPS MUST ALLOW 3/4" MOVEMENT. 9. CEILINGS OVER 2,500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITIONS. 10. CEILINGS WITHOUT RIGID BRACING MUST HAVE A 2" OVERSIZED TRIM RING FOR SPRINKLERS & OTHER PENETRATION. 11. CHANGES IN THE CEILING PLANE MUST HAVE POSITIVE BRACING. 12. CABLE TRAYS & ELECTRICAL CONDUITS MUST BE INDEPENDENTLY SUPPORTED & BRACED. 13. IF PARTITIONS ARE ATTACHED TO THE SUSPENDED CEILING SYSTEM, THEY MUST BE LATERALLY BRACED TO THE BUILDING STRUCTURE. 14. VERTICAL HANGER WIRES ARE TO BE: • 14.1 NOT MORE THAN 4' ON CENTER • 14.2 MUST PLUMP WITHIN 1 IN 6 • 14.3 TIED WITH THREE TURNS IN 3" OR LESS. • 14.4 MINIMUM 12 GAUGE GALVANIZED SOFT - ANNEALED, MILD STEEL WIRE. 15. PENDANT MOUNTED FIXTURES MUST BE SUPPORTED FROM THE STRUCTURE WITH NO LESS THAN 9 GAUGE WIRE. THEY MAY NOT USE THE CEILING SUSPENSION FOR SUPPORT. 16. LIGHT FIXTURES MUST BE POSITIVELY ATTACHED TO THE SUSPENDED SYSTEM. ATTACHED DEVICE MUST BE ABLE TO WITHSTAND 100 % OF THE FIXTURE WEIGHT. 17. IF THE LIGHT FIXTURE IS 56 POUNDS OR LESS, MUST HAVE TWO 12-GA. WIRES ATTACHED AT DIAGONAL CORNERS. IF MORE THAN 56 POUNDS MUST BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE. NOTES: 1. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90° FROM EA. OTHER AT AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF THE CEILING AND LOCATED 12'-0" ON CENTER BOTH WAYS STARTING 6' FROM TWO ADJACENT WALLS. 2. FOR ROOMS WITH SPAN IN EITHER DIRECTION LESS THAN 25', MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER OF TWO ADJACENT WALLS WITH 3/8" CLEARANCE BETWEEN THE RUNNERS AND THE OTHER TWO WALLS. WHERE SPAN OF THE CEILING SYSTEM BETWEEN PERIMETER WALLS EXCEED 25' IN BOTH DIRECTIONS, A MINIMUM WALL ANGLE SIZE OF AT LEAST 2" HORIZONTAL LEG SHALL BE USED AT PERIMETER WALLS AND INTERIOR FULL HEIGHT PARTITION. THE FIRST TILE SHALL BE 3/4" CLEAR FROM WALL SURFACE. 3. WHEN THE DISTANCE BETWEEN THE STRUCTURAL DECK AND THE CEILING EXCEEDS 4', THE SPACING OF THE VERTICAL HANGERS SHALL NOT EXCEED 2' O.C. ALONG THE ENTIRE LENGTH OF THE MEANS OF EGRESS SERVICING AN OCCUPANT LOAD OF 30 OR MORE, AND AT LOBBIES ACCESSORY TO GROUP A OCCUPANCIES. 4. LATERAL FORCE-BRACING MEMBERS FOR SUSPENDED CEILINGS SHALL BE A MINIMUM OF 6" FROM ALL HORIZONTAL PIPING OR DUCT WORK NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND STRUCTURE AND SHALL SUPPORT A DESIGN LOAD THE GREATER OF 200 POUNDS OR THE ACTUAL LOAD, WITH A SAFETY FACTOR OF 2. 5. SUSPENDED CEILING SHALL COMPLY WITH SECTION 803.1 AND 808 (2022 CBC) AND ASCE 7-16. 6. SPECIAL INSPECTION IS REQUIRED FOR THE SUSPENDED CEILING AND ITS ANCHORAGE IN SEISMIC CATEGORY D, E & F PER 2022 CBC SEC. 1705.14.2 (SPECIAL INSPECTION FOR NON-STRUCTURAL COMPONENTS) 7. LATERAL BRACING FOR SUSPENDED CEILING MUST BE PROVIDED. WHERE THE CEILING IS NOT SUPPORTING INTERIOR PARTITIONS, CEILING BRACING SHALL BE PROVIDED BY FOUR NO. 12 GAUGE WIRES SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF CEILING. A STRUT (ADEQUATE TO RESIST VERTICAL COMPONENT FROM LATERAL LOADS) FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS OF ROOF OR FLOOR ABOVE. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12 FT. ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FT. (PER ASTM E580 SECTION 5.2.8.2) OF TWO ADJACENT WALLS. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. OTHERWISE, PROVIDE A STRUCTURAL DESIGN. 8. IN LIEU OF A 2" WALL ANGLE USE ARMSTRONG CEILING FRAMING SYSTEM PER ICC-ES REPORT ESR-1308, ICC-ES APPROVED HEAVY DUTY GRID, PRELUDE XL GRID INSTALLED PER REPORT FOR SEISMIC CATEGORY D. E AND F. • USE 7/8" WALL ANGLE. • BERC-2 CLIPS INSTALLED ON THE TWO ADJACENT WALLS WHERE THE RUNNERS MUST BE FIXED, ARE ATTACHED TO THE RUNNER BY A SHEET METAL SCREW THROUGH THE HORIZONTAL SLOT OR FIXED HOLE IN THE CLIP INTO THE WEB OF THE RUNNER. BERC-2 CLIPS INSTALLED ON OPPOSITE WALLS WHERE THE RUNNERS MUST NOT BE FIXED TO THE CLIPS MUST ALLOW THE TERMINAL RUNNER END TO MOVE 3/4 INCH. • FOLLOW ICC APPROVED ESR-1308 FOR INSTALLATION DETAILS. 9. PROVIDE SEISMIC SEPARATION FOR CEILING OVER 2500 SF PER ASCE 7-16 SECTION 13.5.6. 10. PROVIDE HOLD DOWN CLIPS (2) PER CROSS TEE LESS THAN 1 LB PER S.F. NEW 362S250-43 COMPRESSION STRUT WITH 4 - #10 x 1-1/2" W.S. TO BLOCKING EXISTING PLYWOOD EXISTING STRUCTURE NEW 2X4 DF#2 BLOCKING. BETWEEN EXISTING JOIST FRAMING @ NEW COMPRESSION STRUT. SEE STRUCTURAL DETAIL 3/S3.1 FOR MORE INFORMATION. COMPRESSSION STRUT ALTERNATE TOP CLIP MECHANICALLY FASTENED TO STRUCTURE 4-#10 SMS SCREWS TO CROSS TEE EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS, AND OTHER PENETRATIONS, SHOW A 2 INCH OVERSIZED RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 INCH IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMODATE 1 INCH OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSION. 1 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 SEISMIC DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 12/19/23 222702550 A-503 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1 1/2" = 1'-0"SUSP. CLNG. BRACING SUPPORT FOR SEISMIC CATERGORY D, E & F 1 SCALE ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 LL 10/28/2024 A-504 4 IN WALL BLOCKING TO SECURE CABINET, TYP 3/4" PARTICLEBOARD ADJUSTABLE SHELF, TYP REFER TO FLOOR PLAN FOR PARTITION TYPE ELEV. 9'-5" AFF 3/4" PARTICLE BOARD DOOR PANEL 1/2" PARTICLEBOARD BACKER PANEL CEILING AS PER REFLECTED CEILING PLAN VA R I E S VA R I E S SEE RCP WALL FINISH AS SCHEDULED LIGHT FIXTURE AS SCHEDULEDEQEQ CONCEALED HINGES, TYP. 1/2" WOOD SPACER, TYP NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. 1'-3" MIRROR, REFER TO SPECIFCATIONS 3/4" MARINE GRADE SUBSTRATE SEE MANUFACTUER INSTALLATION DETAILS FOR MORE INFORMATION 1/4" ALUM Z-CLIPS COUNTERTOP: SET IN MASTIC OR JOINT ADHESIVE. SCRIBE TO WALL HO L D 9" M I N . 1 1 / 2 " 1/ 4 " 5 1 / 4 " 1/ 4 " PE R SI N K I N S TA L L A T I O N DO O R P A N E L . V E R I F Y NO S E O F S I N K 2'- 1 0 " M A X . SINK AS SCHEDULED SCHEDULED COUNTERTOP, SEE ELEVATION FOR FINISH MATERIAL 1'-2"10 1/2" TO B O T T O M O F T H E R E F L E C T I N G S U R F A C E 3' - 4 " M A X . FLOOR FINISH AS SCHEDULED WALL FINISH AS SCHEDULED WALL FINISH AS SCHEDULED DOOR PANEL FIXED PANEL IN WALL BLOCKING TO SECURE CABINET, TYP A-504 3 HOLD 6" MAX.11" MIN. 2'- 3 " M I N . 6" S I N K B O W L 8" MIN. CONCEALED HINGES, TYP. NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. REFER TO TYPICAL ACCESSIBILITY DETAILS FOR KNEE AND TOE CLEARANCE IN G-SERIES. INSULATE HOT WATER PIPES & DRAIN 2'- 9 " 1/4" CO O R D I N A T E H E I G H T W I T H S I N K A-504 3 INTEGRAL TOE KICK, NOTCH AS REQUIRED TO ALLOW DOORS TO SWING OPEN, P-LAM FINISH, REFER TO ELEVATIONS INSULATE HOT WATER PIPES & DRAIN, ENSURE THERE ARE NO SHARP OR ABRASIVE OBJECTS UNDER SINK CONCEALED HINGE 1/2" PARTICLEBOARD BACKER PANEL 1/2" WD SPACER, TYP SCHEDULED COUNTERTOP, SEE ELEVATION FOR FINISH MATERIAL 4" SCHEDULED SINK AND FAUCET 2'-0" 2'- 1 0 " M A X . BRACING AS REQUIRED 3/4" PARTICLEBOARD DOOR PANEL 5" RE V E AL 1/ 4 " 7" M A X WALL FINISH AS SCHEDULED (TILE WHERE SCHEDULED) FLOOR FINISH AS SCHEDULED 3/4" PARTICLEBOARD FIXED PANEL, ALIGN WITH ADJACENT DRAWERS IN WALL BLOCKING TO SECURE CABINET, TYP 3" 3/4" MARINE GRADE SUBSTRATE 9" M I N . 2'- 3 " M I N . HOLD 6" MAX. 8" MIN. NOTES: 1. ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. 2. REQUIRED KNEE AND TOE CLEARANCE TO BE KEPT FREE OF ANY OBJECTS PER DETAILS IN G-SERIES. IN WALL BLOCKING TO SECURE CABINET, TYP 1/2" BACKER PANEL 1/2" WOOD SPACER, TYP SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEV. FOR FINISH MELAMINE, ALL INTERIOR EXPOSED AND SEMI- EXPOSED SURFACES 2'-0" 3/4" PARTICLEBOARD SLIDE OUT DOOR PANEL MIN. INTERIOR CABINET DIMENSIONS: 22-1/8"W x 17-5/8"D x 17-7/8"H RICHELIEU 31.7QT CAPACITY BIN; PRODUCT #:361330100, QTY (2) RICHELIEU EURO-CARGO RECYCLING CENTER; PRODUCT #: 461162100; FASTENED TO CABINET PER MANUFACTURER'S STANDARD BASE FINISH AS SCHEDULED FLOOR FINISH AS SCHEDULED BLOCKING AS REQUIRED FOR WASTE RECEPTACLE HARDWARE ATTACHMENT BLOCKING, TYP DRAWERS: 3/4" PARTICLEBOARD PANEL FRONT W/ 1/2" BIRCH VENEER CORE PLYWOOD SIDES & 1/4" BIRCH VENEER CORE PLYWOOD BOTTOM 3/4" PARTICLEBOARD DUST PANEL; EDGE TO MATCH EXTERIOR, TYP 3"4" 3/4" x 4" STRETCHER W/ FINISH ON FRONT EDGE TO MATCH EXTERIOR NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. CABINET BASE COUNTERTOP UNDERSUPPORT 3/4" PARTICLEBOARD DRAWER FRONT A-504 2 WALL FINISH AS SCHEDULED (TILE WHERE SCHEDULED; REFER TO INTERIOR ELEVATIONS) CONCEALED HINGES, TYP. 3/4" PARTICLEBOARD DOOR PANEL IN WALL BLOCKING TO SECURE CABINET 1/2" PARTICLEBOARD BACKER PANEL 3/4" PARTICLEBOARD ADJUSTABLE SHELF 3/4" x 4" STRETCHER W/ FINISH ON FRONT EDGE TO MATCH EXTERIOR CABINET BASE 1/2" WOOD SPACER, TYP SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEVATIONS FOR FINISH RE F E R T O E L E V A T I O N S 4" 2'-0" 3" BASE FINISH AS SCHEDULED FLOOR FINISH AS SCHEDULED WALL FINISH AS SCHEDULED (TILE WHERE SCHEDULED; REFER TO INTERIOR ELEVATIONS) A-504 3 NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. COUNTERTOP UNDERSUPPORT SEALANT 4" HIGH BACKSPLASH, TO MATCH COUNTERTOP SURFACE (WHERE INDICATED IN ELEVATIONS) IN WALL BLOCKING TO SECURE CABINET, TYP 1/2" PARTICLE BOARD BACKER PANEL CABINET BASE 1/2" WOOD SPACER, TYP DRAWERS: 3/4" PARTICLE BOARD PANEL FRONT W/ 1/2" BIRCH VENEER CORE PLYWOOD SIDES & 1/4" BIRCH VENEER CORE PLYWOOD BOTTOM CLEAR INSIDE DRAWER, TYP. 1'-8" SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEVATIONS FOR FINISH RE F E R T O E L E V A T I O N S 2'-0" 3" FLOOR FINISH AS SCHEDULED 3/4" PARTICLE BOARD DUST PANEL; EDGE TO MATCH EXTERIOR, TYP EQ 1/ 4 " EQ 1/4 " EQ 1/4 " EQ 4" BASE FINISH AS SCHEDULED A-504 2 3/4" x 4" STRETCHER W/ FINISH ON FRONT EDGE TO MATCH EXTERIOR NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. COUNTERTOP UNDERSUPPORT 3/4" PARTICLE BOARD DRAWER FRONT, TYP. WALL FINISH AS SCHEDULED (TILE WHERE SCHEDULED) 2'-0" SCHEDULED PARTITION 2'- 6 " RICHELIEU KOLOSSUS FLOATING COUNTER BRACKET; PRODUCT #: 68121690; PROVIDE SUPPORT PER MANUFACTURER'S STANDARD WOOD STUD BLOCKING AT SUPPORT 4" HIGH BACKSPLASH, TO MATCH COUNTERTOP SURFACE (WHERE INDICATED IN ELEVATIONS) 1/4" PARTICLE BOARD SUBSTRATE CABLE GROMMET AS SPECIFIED; REFER TO PLANS FOR LOCATIONS AND QUANTITIES WALL FINISH AS SCHEDULED (TILE WHERE SCHEDULED) BASE FINISH AS SCHEDULED FLOOR FINISH AS SCHEDULED SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEVATIONS FOR FINISH 2'- 3 " M I N . C L E A R 1 1 / 2 " SEALANT UNDER COUNTER EQUIPMENT VERIFY CLEARANCE REQUIREMENTS P-LAM END PANELS WHERE OCCURS FLOOR FINISH AS SCHEDULED WOOD STUD BLOCKING AT SUPPORT SCHEDULED COUNTERTOP, SCRIBE TO WALL REFER TO ELEVATIONS FOR FINISH NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH 1 1 / 2 " RE F E R T O E L E V A T I O N S RICHELIEU KOLOSSUS FLOATING COUNTER BRACKET; PRODUCT #: 68121690; PROVIDE SUPPORT PER MANUFACTURER'S STANDARD WALL FINISH AS SCHEDULED (TILE WHERE SCHEDULED) BASE FINISH AS SCHEDULED 1/4" PARTICLE BOARD SUBSTRATE 2'-0" IN WALL BLOCKING TO SECURE CABINET 1/2" PARTICLE BOARD BACKER PANEL CABINET BASE 1/2" WOOD SPACER, TYP DRAWERS: 3/4" PARTICLE BOARD PANEL FRONT W/ 1/2" BIRCH VENEER CORE PLYWOOD SIDES & 1/4" BIRCH VENEER CORE PLYWOOD BOTTOM EQ 3/4" PARTICLE BOARD DUST PANEL; EDGE TO MATCH EXTERIOR, TYP EQ CLEAR INSIDE DRAWER, TYP. 1'-7 1/2" SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEVATIONS FOR FINISH RE F E R T O E L E V A T I O N S NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. A-504 2 WALL FINISH AS SCHEDULED FLOOR FINISH AS SCHEDULED BASE FINISH AS SCHEDULED 3" RICHELIEU METABOX METAFILE SYSTEM; PRODUCT #: ZRM550100, TYP EACH DRAWER 4" 3/4" x 4" STRETCHER W/ FINISH ON FRONT EDGE TO MATCH EXTERIOR 2'-0" COUNTERTOP UNDERSUPPORT 3/4" PARTICLEBOARD DRAWER FRONT, TYP. SEALANT 4" HIGH BACKSPLASH, TO MATCH COUNTERTOP SURFACE (WHERE INDICATED IN ELEVATIONS) ADA COMPLIANT METAL DOOR PULL: RICHELIEU CONTEMPORARY METAL PULL; PRODUCT #: BP56325128195; BRUSHED NICKEL FINISH; INSTALL IN LOCATIONS AS INDICATED IN MILLWORK SCHEDULE 1 1 / 2 " 1/ 4 " 2" SPACE BETWEEN COUNTERTOP OR ADJACENT PANEL B -ADA COMPLIANT 1/2" ADA COMPLIANT METAL DRAWER PULL: RICHELIEU CONTEMPORARY METAL PULL; PRODUCT #: BP56325128195; BRUSHED NICKEL FINISH; INSTALL IN LOCATIONS AS INDICATED IN MILLWORK SCHEDULE; CENTER WITHIN DRAWER FRONT 1 1 / 2 " 1/ 4 " 2" SPACE BETWEEN COUNTERTOP OR ADJACENT PANEL B -ADA COMPLIANT 1/2" ADA COMPLIANT METAL DOOR PULL: RICHELIEU CONTEMPORARY METAL PULL; PRODUCT #: BP56325128195; BRUSHED NICKEL FINISH; INSTALL IN LOCATIONS AS INDICATED IN MILLWORK SCHEDULE 2"2" ALIGN 3/4" PARTICLE BOARD LIGHT VALENCE B -ADA COMPLIANT GENERAL NOTES -MILLWORK DETAILS 1. ALL MILLWORK DEPTH TO BE 24" U.N.O. 2. REFER TO INTERIOR ELEVATIONS AND FINISH SCHEDULE FOR ALL FINISHES AND LOCATIONS. 3. REFER TO INTERIOR ELEVATIONS FOR QUANTITY OF SHELVING PER EACH CABINET. 4. FLOOR FINISHES TO EXTEND BENEATH ALL MILLWORK. 5. REFER TO PLUMBING SCHEDULE FOR MORE INFORMATION. 6. PROVIDE FILLER PANELS AT ALL MILLWORK WHEN LOCATED ADJACENT TO WALL. 7. G.C. TO PROVIDE SHOP DRAWINGS OF ALL MILLWORK AND HARDWARE FOR REVIEW AND APPROVAL BY ARCHITECT. 8. REFER TO MILLWORK SCHEDULE ON SHEET A-605 FOR ALL LOCK, KEY AND HARDWARE REQUIREMENTS. MILLWORK HARDWARE SCHEDULE: 1. ALL DOOR FRONT, DRAWER FRONT, FIXED PANEL AND CABINET STRUCTURE SUBSTRATES TO BE 3/4" PARTICLE BOARD WITH P-LAM SURFACES AND MATCHING 3MM EDGE BAND, UNO. 2. PROVIDE MATCHING 3MM PVC EDGE BAND; DOOR AND DRAWER PANELS. 3. PROVIDE MARINE GRADE SUBSTRATE MILLWORK AT ALL SINK LOCATIONS. 4. ALL EXPOSED GABLES AND SHELVING TO BE 3/4" PARTICLE BOARD WITH P-LAM ON BOTH FACES AND MATCHING 3MM PVC EDGE BAND. 5. ALL COVERED GABLES AND SHELVING TOP AND BOTTOM PLATES TO BE 3/4" PARTICLE BOARD WITH MELAMINE AND MATCHING 1MM PVC EDGE BAND. 6. ALL CABINET BACKER PANELS TO BE MIN. 1/2" HARDBOARD PANEL WITH MELAMINE FINISH ON EXPOSED FACE. 7. BASE KICK PANEL TO BE 3/4" PLYWOOD WITH PLASTIC LAMINATE FINISH ON EXPOSED FACES AND MATCHING 1MM PVC EDGE BAND. 8. PLASTIC LAMINATE COUNTERTOPS TO HAVE FINISH P-LAM FINISH APPLIED TO ALL EXPOSED FACES; PROVIDE 1/2" PLYWOOD UNDERSUPPORT. 9. ALL EXPOSED MILLWORK EDGES TO HAVE P-LAM OR MATCHING PVC EDGE BAND. MILLWORK CABINET CONSTRUCTION SCHEDULE: BALL-BEARING ACCURIDE BALL-BEARING DRAWER SLIDES; PRODUCT #: 3832 OR APPROVED EQUAL, TYP HINGE RICHELIEU; 107 DEGREE BLUM HINGE WITH 86 ANGLE RESTRICTION CLIP; PRODUCT #: 741103 OR APPROVED EQUAL, TYP METAL CABINET STANDARDS RICHELIEU; U-SHAPE ALUMINUM PILASTER; PRODUCT #: 2552 OR APPROVED EQUAL, TYP TYPE PRODUCT MANUFACTURER / NUMBER BUMPERS CLEAR SELF-ADHESIVE BUMPERS WHERE CABINET DOOR PULL MAKES CONTACT WITH ADJACENT WALL OR MILLWORK METAL CABINET SHELF CLIP RICHELIEU; KOLOSSUS PILASTER SHELF CLIP; PRODUCT #: 62162; FINISH: ZINC; PROVIDE QTY (4) EACH SHELF LOCK -DOUBLE DOOR HAFELE PRODUCT #: 232.35.300; APPLY WITH DOUBLE STRAIGHT BOLTS C/W MORTISE AND TAB STRIKES LOCK -DRAWER HAFELE PRODUCT #: 232.18.316; TO BE EXTENDED STRAIGHT BOLT WITH C/W MORTISE STRIKE PANEL CONNECTOR HAFELE PRODUCT #: 260.15.300; COLOR: BLACK CONCEALED COUNTER BRACKET RICHELIEU; KOLOSSUS FLOATING COUNTER BRACKET; PRODUCT #: 68121690; PROVIDE SUPPORT PER MANUFACTURER'S STANDARD; REFER TO MILLWORK DETAILS GROMMET RICHELIEU; 2.5" BOREHOLE; PRODUCT #: 166021174; FINISH: SATIN CHROME; TYP ALL GROMMET LOCATIONS ADA -DOOR & DRAWER PULL STANDARD - DOOR & DRAWER PULL RICHELIEU; METAL EDGE PULL; PRODUCT # 39660195; BRUSHED NICKEL FINISH; REFER TO MILLWORK DETAILS RICHELIEU; CONTEMPORARY METAL PULL; PRODUCT #: BP56325128195; BRUSHED NICKEL FINISH; REFER TO MILLWORK DETAILS CLOSET ROD KNAPE & VOGT; 770 5 SERIES EXTRA HEAVY-DUTY ROUND CLOSET ROD; 1-5/16" DIA.; FINISH: CHROME & KNAPE & VOGT; 764 FLANGE FOR ROUND TUBING; REFER TO MILLWORK DETAILS SHELF BRACKET SYSTEM RICHELIEU; HEAVY-DUTY BRACKET, SERIES #187; PRODUCT #: 18712170 & RICHELIEU HEAVY-DUTY STANDARD, SERIES #87; PRODUCT #: 8760170; STAINLESS STEEL FINISH; REFER TO MILLWORK DETAILS FLOATING SHELF BRACKET RICHELIEU; 9" FLOATING SHELF BRACKET; PRODUCT #: 62400930; REFER TO MILLWORK DETAILS FILE HANGING HARDWARE RICHELIEU; METABOX METAFILE SYSTEM; PRODUCT #: ZRM550100; REFER TO MILLWORK DETAILS IN WALL BLOCKING TO SECURE CABINET 1/2" PARTICLEBOARD BACKER PANEL CABINET BASE 1/2" WOOD SPACER, TYP DRAWERS: 3/4" PARTICLEBOARD PANEL FRONT W/ 1/2" BIRCH VENEER CORE PLYWOOD SIDES & 1/4" BIRCH VENEER CORE PLYWOOD BOTTOM 3/4" PARTICLEBOARD DUST PANEL; EDGE TO MATCH EXTERIOR, TYP 1'- 0 " 1/ 4 " 6" 1/ 4 " 6"CLEAR INSIDE DRAWER, TYP. 1'-7 1/2" NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. FLOOR FINISH AS SCHEDULED BASE FINISH AS SCHEDULED 3" RICHELIEU METABOX METAFILE SYSTEM; PRODUCT #: ZRM550100, TYP EACH DRAWER 1'-11 1/2" 4" COUNTERTOP UNDERSUPPORT 3/4" PARTICLEBOARD DRAWER FRONT, TYP. SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEVATIONS FOR FINISH 3/4" x 4" STRETCHER W/ FINISH ON FRONT EDGE TO MATCH EXTERIOR 2'-0" 2' - 6 " A-504 2 WALL FINISH AS SCHEDULED IN WALL BLOCKING TO SECURE CABINET 1/2" PARTICLEBOARD BACKER PANEL CABINET BASE 1/2" WOOD SPACER, TYP DRAWERS: 3/4" PARTICLEBOARD PANEL FRONT W/ 1/2" BIRCH VENEER CORE PLYWOOD SIDES & 1/4" BIRCH VENEER CORE PLYWOOD BOTTOM 3/4" PARTICLEBOARD DUST PANEL; EDGE TO MATCH EXTERIOR, TYP 1'- 0 " 1/ 4 " 1'- 0 " CLEAR INSIDE DRAWER, TYP. 1'-7 1/2" NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. FLOOR FINISH AS SCHEDULED BASE FINISH AS SCHEDULED 3" RICHELIEU METABOX METAFILE SYSTEM; PRODUCT #: ZRM550100, TYP EACH DRAWER 4" COUNTERTOP UNDERSUPPORT 3/4" PARTICLEBOARD DRAWER FRONT, TYP. SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEVATIONS FOR FINISH 3/4" x 4" STRETCHER W/ FINISH ON FRONT EDGE TO MATCH EXTERIOR 2'-0" 2' - 6 " A-504 2 WALL FINISH AS SCHEDULED 4" HIGH BACKSPLASH, TO MATCH COUNTERTOP SURFACE (WHERE INDICATED IN ELEVATIONS) SEALANT IN WALL BLOCKING TO SECURE CABINET, TYP 1/2" PARTICLEBOARD BACKER PANEL 1/2" WOOD SPACER, TYP DRAWERS: 3/4" PARTICLEBOARD PANEL FRONT W/ 1/2" BIRCH VENEER CORE PLYWOOD SIDES & 1/4" BIRCH VENEER CORE PLYWOOD BOTTOM 1/ 4 " 7" 3/4" PARTICLEBOARD DUST PANEL; EDGE TO MATCH EXTERIOR, TYP CLEAR INSIDE DRAWER, TYP. 1'-8" SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEVATIONS FOR FINISH RE F E R T O E L E V A T I O N S 2'-0" BASE FINISH AS SCHEDULED FLOOR FINISH AS SCHEDULED 3/4" PARTICLEBOARD ADJUSTABLE SHELF 3/4" PARTICLEBOARD DOOR PANEL 3" A-504 2 A-504 3 4" NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. CONCEALED HINGES, TYP. COUNTERTOP UNDERSUPPORT WALL FINISH AS SCHEDULED (TILE WHERE SCHEDULED) 4" HIGH BACKSPLASH, TO MATCH COUNTERTOP SURFACE (WHERE INDICATED IN ELEVATIONS) SEALANT 3/4" SHELF SURROUND; P-LAM ALL SURFACES & EDGES; SEQUENCE FOR PLASTIC LAMINATE: EDGES FIRST, FACES SECOND. RICHELIEU 9" FLOATING SHELF BRACKET; PRODUCT #: 62400930 PROVIDE BLOCKING OR ADDITIONAL STEEL STUDS W/ IN WALL AT EACH MOUNTING BRACKET; PROVIDE BRACKETS PER MANUFACTURER'S RECOMMENDATION WALL FINISH AS SCHEDULED WALL TILE AS SCHEDULED PROVIDE ALL REQUIRED FASTENING HARDWARE PER MANUFACTURER'S STANDARD FOR ATTACHING BRACKET TO WALL AND SHELF TO BRACKET 1'-3" 3" x 3" TYP CORNER FILLER. 2-1/2" x 2-1/2" MIN. CORNER FILLER REQUIRED FOR CLEARANCE BETWEEN DRAWER AND PULL OF ADJACENT CABINET. MAY VARY BASED ON PULL. 1/ 4 " 2 3 / 4 " 1/4" 2 3/4" 3" 3" WALL FINISH AS SCHEDULED BE T W EE N M E TA L S T U D S 3 X W O O D B L O C K I N G X 5 ' - 0 " L O N G M I N . (N) 362S250-54 @ 16" O.C. FULL HEIGHT STUD 2'-2" 1/2" DIA. X 4" LAG SCREWS AT (2) LOCATIONS APPROVED MIN. 16 GAUGE 1-1/2" WIDE SEISMIC STRAPS T&B WALL MOUNTED WATER HEATER PLATFORM; HOLDRITE MODEL # 50-SWHP-WM HOT WATER HEATER AND 2.5" DRIP PAN (MAX. OPERATING WEIGHT 400 POUNDS 1/2" DIA. X 4" LAG SCREWS AT (2) LOCATIONS 5/16" X 2 1/2" LAG BOLTS 5/16" X 2 1/2" LAG BOLTS 6'-8" MIN. TO BOTTOM OF PAN 2 ROWS OF #8 SCREWS @ 6" O.C. MAXCOORDINATE WITH STRUCTURAL THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 MILLWORK DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-504 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALESCALE SCALESCALE SCALE SCALESCALESCALESCALE SCALESCALESCALESCALE 1 1/2" = 1'-0"UPPER CABINET W/ DOORS 18 1 1/2" = 1'-0"RESTROOM VANITY AND LAVATORY 71 1/2" = 1'-0"STAFF ROOM CABINET W/LAVATORY 8 1 1/2" = 1'-0"BASE CAB W/ TRASH PULLOUT 17 1 1/2" = 1'-0"BASE CABINET W/ DOORS 16 1 1/2" = 1'-0"BASE CABINET (4) DRAWER 111 1/2" = 1'-0"WORKSTATION COUNTERTOP 121 1/2" = 1'-0"COUNTERTOP OVER EQUIPMENT 13 1 1/2" = 1'-0"BASE CABINET (2) DRAWER FILE 15 3" = 1'-0"DOOR PULL DETAILS - LOWER 3 3" = 1'-0"DRAWER PULL DETAILS - LOWER 23" = 1'-0"DOOR PULL DETAILS - UPPER 41 1/2" = 1'-0"BASE CABINET BFF 30"H 5 1 1/2" = 1'-0"BASE CABINET FF 30"H 10 1 1/2" = 1'-0"BASE CABINET WITH DRAWER 9 SCALE SCALESCALE SCALE SCALE 1 1/2" = 1'-0"STAFF ROOM FLOATING SHELF 14 1 1/2" = 1'-0"CORNER CABINET DETAIL 1 1 1/2" = 1'-0"WATER HEATER PLATFORM 6 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 5'- 6 " 7 1 / 4 " 4'- 1 0 3 / 4 " TO C E N T E R L I N E O F R O D 5' - 1 " 3/4" FIXED SHELF AND CABINET STRUCTURE; P-LAM ALL EXPOSED SURFACES 1 5/16" COAT ROD AND SUPPORT A-505 6_________________ A-505 1_________________ 1 5/16" COAT ROD AND SUPPORT 3' - 1 0 " M A X TO C E N T E R L I N E O F R O D 3' - 5 3 / 4 " PL-4A EQ 3/4"EQ 1 5/16" COAT ROD AND SUPPORT 3/4" SHELF STRUCTURE; P-LAM ALL EXPOSED SURFACES 7 1 / 4 " RE F E R T O E L E V A T I O N PROVIDE BLOCKING IN WALL AS REQUIRED WAL FINISH AS SCHEDULED WALL FINISH AS SCHEDULED PL-4A 1 5/16" COAT ROD AND SUPPORT 7 1 / 4 " RE F E R T O E L E V A T I O N 1 1 / 2 " 3/4" FIXED SHELF AND CABINET STRUCTURE; P-LAM ALL EXPOSED SURFACES RE F E R T O E L E V A T I O N PROVIDE BLOCKING IN WALL AS REQUIRED WALL FINISH AS SCHEDULED WALL FINISH AS SCHEDULED PL-4A A-504 4 A-504 2 A-504 3 JUNCTION BOX, MOUNTED HORIZONTALLY CENTERED ON BACK FACE AT HEIGHT NOTED 3/4" PARTICLEBOARD DOOR PANEL 1/2" PARTICLEBOARD BACKER PANEL1/2" WOOD SPACER, TYP IN WALL BLOCKING TO SECURE CABINET, TYP DRAWERS: 3/4" PARTICLEBOARD PANEL FRONT W/ 1/2" BIRCH VENEER CORE PLYWOOD SIDES & 1/4" BIRCH VENEER CORE PLYWOOD BOTTOM AD J A C E N T AL I G N W I T H 3/4" PARTICLEBOARD DUST PANEL; EDGE TO MATCH EXTERIOR, TYP CLEAR INSIDE DRAWER, TYP. 1'-8" SCHEDULED COUNTERTOP, SCRIBE TO WALL, REFER TO ELEVATIONS FOR FINISH 3'- 7 1 / 2 " 1/ 4 " R E V E A L PE R MA N U F A CT U R E R MI C R O W A V E O P E N I N G 1/ 4 " R E V E A L RE F E R T O E L E V A T I O N S BASE FINISH AS SCHEDULED FLOOR FINISH AS SCHEDULED 3/4" PARTICLEBOARD ADJUSTABLE SHELF 3/4" PARTICLEBOARD DOOR PANEL 3/4" PARTICLEBOARD DRAWER PANEL 3" NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. 1'-11 1/2" 3/4" PARTICLEBOARD ADJUSTABLE SHELF, TYP 8'- 0 " COUNTERTOP UNDERSUPPORT MICROWAVE TRIM KIT MICROWAVE; REFER TO EQUIPMENT SCHEDULE FOR MORE INFORMATION SCRIBE TO SOFFIT SOFFIT ABOVE WALL FINISH AS SCHEDULED PROVIDE FINISHED INTERIOR CAVITY AS REQUIRED FOR MICROWAVE AND MICROWAVE TRIM KIT ALIGN BRACKET PER MANUFACTURER ELEV. SEE RCP GENERAL NOTES -MILLWORK DETAILS 1. ALL MILLWORK DEPTH TO BE 24" U.N.O. 2. REFER TO INTERIOR ELEVATIONS AND FINISH SCHEDULE FOR ALL FINISHES AND LOCATIONS. 3. REFER TO INTERIOR ELEVATIONS FOR QUANTITY OF SHELVING PER EACH CABINET. 4. FLOOR FINISHES TO EXTEND BENEATH ALL MILLWORK. 5. REFER TO PLUMBING SCHEDULE FOR MORE INFORMATION. 6. PROVIDE FILLER PANELS AT ALL MILLWORK WHEN LOCATED ADJACENT TO WALL. 7. G.C. TO PROVIDE SHOP DRAWINGS OF ALL MILLWORK AND HARDWARE FOR REVIEW AND APPROVAL BY ARCHITECT. 8. REFER TO MILLWORK SCHEDULE ON SHEET A-605 FOR ALL LOCK, KEY AND HARDWARE REQUIREMENTS. MILLWORK HARDWARE SCHEDULE: 1. ALL DOOR FRONT, DRAWER FRONT, FIXED PANEL AND CABINET STRUCTURE SUBSTRATES TO BE 3/4" PARTICLE BOARD WITH P-LAM SURFACES AND MATCHING 3MM EDGE BAND, UNO. 2. PROVIDE MATCHING 3MM PVC EDGE BAND; DOOR AND DRAWER PANELS. 3. PROVIDE MARINE GRADE SUBSTRATE MILLWORK AT ALL SINK LOCATIONS. 4. ALL EXPOSED GABLES AND SHELVING TO BE 3/4" PARTICLE BOARD WITH P-LAM ON BOTH FACES AND MATCHING 3MM PVC EDGE BAND. 5. ALL COVERED GABLES AND SHELVING TOP AND BOTTOM PLATES TO BE 3/4" PARTICLE BOARD WITH MELAMINE AND MATCHING 1MM PVC EDGE BAND. 6. ALL CABINET BACKER PANELS TO BE MIN. 1/2" HARDBOARD PANEL WITH MELAMINE FINISH ON EXPOSED FACE. 7. BASE KICK PANEL TO BE 3/4" PLYWOOD WITH PLASTIC LAMINATE FINISH ON EXPOSED FACES AND MATCHING 1MM PVC EDGE BAND. 8. PLASTIC LAMINATE COUNTERTOPS TO HAVE FINISH P-LAM FINISH APPLIED TO ALL EXPOSED FACES; PROVIDE 1/2" PLYWOOD UNDERSUPPORT. 9. ALL EXPOSED MILLWORK EDGES TO HAVE P-LAM OR MATCHING PVC EDGE BAND. MILLWORK CABINET CONSTRUCTION SCHEDULE: BALL-BEARING ACCURIDE BALL-BEARING DRAWER SLIDES; PRODUCT #: 3832 OR APPROVED EQUAL, TYP HINGE RICHELIEU; 107 DEGREE BLUM HINGE WITH 86 ANGLE RESTRICTION CLIP; PRODUCT #: 741103 OR APPROVED EQUAL, TYP METAL CABINET STANDARDS RICHELIEU; U-SHAPE ALUMINUM PILASTER; PRODUCT #: 2552 OR APPROVED EQUAL, TYP TYPE PRODUCT MANUFACTURER / NUMBER BUMPERS CLEAR SELF-ADHESIVE BUMPERS WHERE CABINET DOOR PULL MAKES CONTACT WITH ADJACENT WALL OR MILLWORK METAL CABINET SHELF CLIP RICHELIEU; KOLOSSUS PILASTER SHELF CLIP; PRODUCT #: 62162; FINISH: ZINC; PROVIDE QTY (4) EACH SHELF LOCK -DOUBLE DOOR HAFELE PRODUCT #: 232.35.300; APPLY WITH DOUBLE STRAIGHT BOLTS C/W MORTISE AND TAB STRIKES LOCK -DRAWER HAFELE PRODUCT #: 232.18.316; TO BE EXTENDED STRAIGHT BOLT WITH C/W MORTISE STRIKE PANEL CONNECTOR HAFELE PRODUCT #: 260.15.300; COLOR: BLACK CONCEALED COUNTER BRACKET RICHELIEU; KOLOSSUS FLOATING COUNTER BRACKET; PRODUCT #: 68121690; PROVIDE SUPPORT PER MANUFACTURER'S STANDARD; REFER TO MILLWORK DETAILS GROMMET RICHELIEU; 2.5" BOREHOLE; PRODUCT #: 166021174; FINISH: SATIN CHROME; TYP ALL GROMMET LOCATIONS ADA -DOOR & DRAWER PULL STANDARD - DOOR & DRAWER PULL RICHELIEU; METAL EDGE PULL; PRODUCT # 39660195; BRUSHED NICKEL FINISH; REFER TO MILLWORK DETAILS RICHELIEU; CONTEMPORARY METAL PULL; PRODUCT #: BP56325128195; BRUSHED NICKEL FINISH; REFER TO MILLWORK DETAILS CLOSET ROD KNAPE & VOGT; 770 5 SERIES EXTRA HEAVY-DUTY ROUND CLOSET ROD; 1-5/16" DIA.; FINISH: CHROME & KNAPE & VOGT; 764 FLANGE FOR ROUND TUBING; REFER TO MILLWORK DETAILS SHELF BRACKET SYSTEM RICHELIEU; HEAVY-DUTY BRACKET, SERIES #187; PRODUCT #: 18712170 & RICHELIEU HEAVY-DUTY STANDARD, SERIES #87; PRODUCT #: 8760170; STAINLESS STEEL FINISH; REFER TO MILLWORK DETAILS FLOATING SHELF BRACKET RICHELIEU; 9" FLOATING SHELF BRACKET; PRODUCT #: 62400930; REFER TO MILLWORK DETAILS FILE HANGING HARDWARE RICHELIEU; METABOX METAFILE SYSTEM; PRODUCT #: ZRM550100; REFER TO MILLWORK DETAILS FLOOR FINISH AS SCHEDULED IN WALL BLOCKING TO SECURE CABINET, TYP 3/4" PARTICLEBOARD FIXED PANEL 1/2" PARTICLE BOARD BACKER PANEL BASE FINISH AS SCHEDULED 5'- 9 " FINISH INFILL PANEL BEYOND; PANEL TO RUN FULL LENGTH WALL FINISH AS SCHEDULED REFRIGERATOR; REFER TO EQUIPMENT SCHEDULE FOR MORE INFORMATION 1/2" WOOD SPACER, TYP BALL CATCH NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. SOFFIT ABOVE SCRIBE TO SOFFIT WALL FINISH AS SCHEDULED ELEV. SEE RCP SUPPORT PANEL OF DESK BEYOND REMOVEABLE PANEL NOTCH +/- 43" TO BOTTOM OF OUTLETS (POWER AND DATA) GROMMET SURFACE MOUNTED POWER AND DATA OUTLETS FOR TCR BEHIND REMOVABLE PANEL TCR 3'- 6 " FURNITURE UNITS BY FURNITURE VENDOR 1'- 6 " +/- 43" TO OULETS (POWER AND DATA) (1) DUPLEX OUTLET AND (1) DATA PORT WITH (2) DATA DROPS FOR TCR BELOW CABINET. TCR SUPPORT PANEL OF DESK BEYOND FURNITURE UNITS BY FURNITURE VENDOR DESK BEYOND HATCHED AREA DENOTES POWER / DATA / SECURITY STUB UP FROM FLOOR TO FURNITURE SYSTEM. REFER TO SLAB PLAN, POWER AND DEVICE PLAN, AND ELECTRICAL SHEETS. A-504 4 IN WALL BLOCKING TO SECURE CABINET, TYP 3/4" PARTICLEBOARD ADJUSTABLE SHELF, TYP REFER TO FLOOR PLAN FOR PARTITION TYPE ELEV. 9'-5" AFF 3/4" PARTICLE BOARD DOOR PANEL 1/2" PARTICLEBOARD BACKER PANEL CEILING AS PER REFLECTED CEILING PLAN 3'- 0 " 1/ 4 " SE E R C P WALL FINISH AS SCHEDULED LIGHT FIXTURE AS SCHEDULEDEQEQ CONCEALED HINGES, TYP. 1/2" WOOD SPACER, TYP NOTE: ALL EXPOSED & SEMI-EXPOSED EXTERIOR SURFACES TO BE P-LAM FINISH. ALL INTERIOR FINISHES TO BE MELAMINE. 1'-3" 3/4" PARTICLEBOARD PANEL 1/4" PARTICLEBOARD REVEAL FINISHED TO MATCH DOOR AND PANEL THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 MILLWORK DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-505 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE 1 1/2" = 1'-0"ELEVATION AT COAT RODS 2 SCALE 1 1/2" = 1'-0"SECTION AT HIGH COAT ROD 1 1 1/2" = 1'-0"SECTION AT LOW COAT ROD 6 1 1/2" = 1'-0"TALL CABINET W/BASE & UPPER 3 SCALE SCALE SCALE SCALE 1 1/2" = 1'-0"FIXED PANEL ABOVE REFRIGERATOR 4 1 1/2" = 1'-0"TCR UNIT - PLAN - POWER AND DATA CONFIGURATION 71 1/2" = 1'-0"TCR UNIT - PLAN - POWER AND DATA CONFIGURATION 8 SCALE SCALE SCALE 1 1/2" = 1'-0"UPPER CABINET W/ DOORS & PANEL 5 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 SE E R C P DISPLAY SCREEN. SEE ELEVATIONS, EQUIPMENT SCHEDULE, AND VENDOR DRAWINGS. WOOD BLOCKING, LEAVE 1.5" FROM FACE OF WOOD SLAT FOR MOUNTING BRACKET MOUNTING BRACKET COORDINATE WITH BMO VENDOR FOR SPECIFICATION. SCHEDULED BASE, SEE FINISH PLAN AND SCHEDULE. SCHEDULED PARTITION WITH PLYWOOD BLOCKING, SEE PARTITION PLAN FOR ADDITIONAL INFORMATION. MILLWORK WOOD SLAT A-506 2_________________ 6 1/4"4" 6" 10 1/4" 2" 4" CO N F I R M D I S P L A Y H E I G H T W I T H V E N D O R D R A W I N G S SEE RCP FOR HT. AFF. LINE OF SURROUND WALL BEYOND RICHELIEU PANEL MOUNTING CLIPS # 918725, 36" O.C. MAX., TYP. SCHEDULED CEILING 11" SCHEDULED RECESSED LIGHT FIXTURE, SEE RCP AND LIGHT FIXTURE SCHEDULE. PT-7 4'- 6 " T O B O T T O M O F S C R E E N PT-7A 1-1/2" x 1/2" ALUMINIUM CHANNEL VERTICAL SLAT, 5/8" MDF, P-LAM AT ALL EXPOSED SURFACES. SEE FINISH SCHEDULE. 1/2" MDF BACK PANEL ATTACHED TO DRYWALL, P-LAM EXPOSED FACE SCHEDULED PARTITION WITH PLYWOOD BLOCKING, SEE PARTITION PLAN FOR ADDITIONAL INFORMATION. RICHELIEU PANEL MOUNTING CLIPS #918725, 36" O.C. MAX. CENTER SLATS ON WALL +/- 2 1/2"2"2"2" 3" 2"DISPLAY SCREEN. SEE ELEVATIONS, EQUIPMENT SCHEDULE, AND AV DRAWINGS. 1/2" MDF SUPPPORT PANEL SCHEDULED PARTITION WITH PLYWOOD BLOCKING, SEE PARTITION PLAN FOR ADDITIONAL INFORMATION. WOOD BLOCKING MOUNTING BRACKET - COORDINATE WITH BMO VENDOR FOR SPECIFICATION A-506 2 PA R T I T I O N P L A N SE E LINE OF MILLWORK WOOD SLATS ABOVELINE OF SOFFIT ABOVE EQ 3'-6" W x 2'-0"H RECESS IN WOOD SLAT WALL EQ 3 A-506 EQ 3'-6" W x 2'-0"H RECESS IN WOOD SLAT WALL EQ 5'-7 1/4"SEE PARTITION PLAN 5'-7 1/4" A-506 4_________________ 3'-6" CLEAR 3'-6" EQ EQ 3'-6" CLEAR 3'-6" EQ EQ MOUNTING BRACKET; COORDINATE WITH BMO VENDOR FOR SPECIFICATION. SCHEDULED DISPLAY SCREEN, SEE INTERIOR ELEVATIONS AND EQUIPMENT SCHEDULE. VERTICAL WOOD BLOCKING AT STUDS POWER / DATA CONNECTIONS AT GYP. BD. WALL, COORDINATE WITH VENDOR DRAWINGS FOR EXACT LOCATIONS. ALL DEVICES, FACEPLATES, POWER CORDS, ETC. TO BE COMPLETELY CONCEALED BEHIND DISPLAY. P-LAM WOOD SLAT, TYP RB-2 PL-21 P-LAM BACKER WALL PANEL VERTICAL SLAT EXTENDS ABOVE CEILING PLANE, SEE DETAIL. LINE OF BANKING HALL CEILING RECESSED SOFFIT CEILING, SEE SECTION DETAIL. PL-7 PT-7A RB-1 6" 10 ' - 0 " 2' - 0 " C L E A R 4' - 1 0 3 / 4 " 4'- 6 " B O T T O M O F D I S P L A Y S C R E E N , T Y P . FL O O R T O C E NT E R L I N E O F D I S P LA Y - C O NF I R M W IT H V E N D OR D R A WI N G S , T YP . 5' - 1 0 3 / 4 " FL O O R T O C E NT E R L I N E O F O U T LE T - C O NF I R M W IT H V E N D OR D R A W IN G S , T Y P. 5' - 2 3 / 4 " RB-1 A-506 1_________________ PT-7APT-7A A-506 4_________________ 5"EQ EQ 5"5"EQ EQ 5" SEE PLAN DETAIL BELOW SEE PLAN DETAIL BELOW 1'-5 1/4" , TYP. A-506 4_________________ RB-2 RB-1RB-1 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 MEDIA SLAT WALL DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 05/17/24 222702550 A-506 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALESCALE SCALE 1 1/2" = 1'-0"MEDIA SLAT WALL - SECTION 4 6" = 1'-0"SECTION DETAIL AT WOOD SLATS, TYP.2 1 1/2" = 1'-0"MEDIA SLAT WALL - PLAN SECTION 1 1 1/2" = 1'-0"MEDIA SLAT WALL - ELEVATION 3 SCALE ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 T = TEMPERED A T = TEMPERED SEE SCHEDULE A SE E S C H E D U L E B VERIFY 6"6" 3'- 6 " VE R I F Y 6" T SE E S C H E D U L E SEE SCHEDULE C 6"VERIFY 6" T 6" VE R I F Y MI N . 10 " SE E S C H E D U L E SEE SCHEDULE D E F 6"VERIFY 6"6"VERIFY 6" T SE E S C H E D U L E EQ EQ 6" VE R I F Y MI N . 10 " SEE SCHEDULE T SEE SCHEDULE SE E S C H E D U L E SE E S C H E D U L E SEE SCHEDULE T G T = TEMPERED SEE SCHEDULE SE E S C H E D U L E 12'-5" V.I.F. NE W S T O R E F R O N T T O A T T A C H T O E X I S T I N G AD J A C E N T S T O R E F R O N T , S E E P R O P O S E D P L A N S . 10 ' - 0 " 7'- 0 " D O O R TTT T T T T 101A 2"1'-5 1/2"2" DOORS 6'-0"2"EQ 2"EQ 2" A-600 5_________________ A-600 6_________________ T T A-501 11_________________ VI F PAINTED HOLLOW METAL FRAME, SEE SCHEDULE AND DETAILS. HOLLOW METAL (HM) A-600 3_________________ A-600 4_________________ SEE PARTITION PLAN FOR WALL TYPES HOLLOW METAL FRAME - HEAD SCHEDULED DOOR JAMB BEYOND PUBLIC SIDE ROOM SIDE SCHEDULED CEILING, SEE RCP. ANGLE BRACING, SEE PARTITION TYPES SHEET A-500. SEALANT, TYP. UN O 2" T Y P . SEE PARTITION PLAN FOR WALL TYPES SCHEDULED DOOR HOLLOW METAL FRAME - JAMB PROVIDE DOUBLE STUDS AT ALL JAMBS, TYP. ROOM SIDE PUBLIC SIDE SEALANT, TYP.UNO 2" TYP. SHIM AND SEALANT AS REQUIRED, TYP. TYPE 'SF2' MULLION, SEE SHEET A-500 FOR SPECIFICATION. SEE WINDOW / GLAZING TYPES FOR MULLION SIZES. 2" WI T H S T O R E F RO N T M F R. CO N F I R M B A S E M U L L I O N H T . TYPE 'SF2' BASE MULLION, TYP. SHIM AND SEALANT AS REQUIRED, TYP. 3/8" CLEAR TEMPERED SAFETY GLASS, SEE STOREFRONT TYPES AND PARTITION TYPES. INSTALL PER STOREFRONT MFR'S INSTRUCTIONS. PUBLIC SIDE ROOM SIDE 4 1/2" PUBLIC SIDE ROOM SIDE TYPE 'SF2' MULLION, SEE SHEET A-500 FOR SPECIFICATION. SEE WINDOW / GLAZING TYPES FOR MULLION SIZES. 4 1/2" 2"SHIM AND SEALANT AS REQUIRED, TYP. SCHEDULED DOOR TEMPERED SAFETY GLASS, 3/8" TEMPERED SAFETY GLASS, 3/8" THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 DOOR SCHEDULE AND DETAILS BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/08/15 222702550 A-600 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 NOTES: 1. SEE FINISH SCHEDULE AND DOOR DETAILS SHEET, FOR ADDITIONAL INFORMATION. 2. GC TO VERIFY CONDITION OF ANY/ALL EXISTING DOORS NOTED TO BE REUSED. NOTIFY ARCHITECT IF EXISTING DOOR IS NOT SUITABLE FOR REUSE. 3. SEE GLASS FILM APPLICATION DETAILS, SHEET A-601. 4. SEE SHEET G-102. G-103, AND A-601 FOR ADDITIONAL DOOR AND HARDWARE INFORMATION. 124 CMR.1 E - DEMOUNTABLE SYSTEM SLIDING DOOR 3'-8" 8'-8" 1 3/4" ALUMINUM / TEMPERED GLASS PREFINISHED ALUMINUM EBONY 10 N/A N/A N/A N/A 1/4" TEMPERED SAFETY GLASS TEKNION ALTOS SYSTEM DOORS & HARDWARE PROVIDED BY FURNITURE VENDOR. SEE SHOP DRAWINGS BY FURNITURE VENDOR. GC TO PREP OPENING FOR ALTOS WALL SYSTEM. 123 CMR.2 E - DEMOUNTABLE SYSTEM SLIDING DOOR 3'-8" 8'-8" 1 3/4" ALUMINUM / TEMPERED GLASS PREFINISHED ALUMINUM EBONY 10 N/A N/A N/A N/A 1/4" TEMPERED SAFETY GLASS TEKNION ALTOS SYSTEM DOORS & HARDWARE PROVIDED BY FURNITURE VENDOR. SEE SHOP DRAWINGS BY FURNITURE VENDOR. GC TO PREP OPENING FOR ALTOS WALL SYSTEM. 122 EMPLOYEE ENCLAVE B - FLUSH W/ 1/4" TEMPERED SAFETY GLASS NARROW LITE 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 04 3/A-600 6/A-602 N/A N/A 1/4" TEMPERED SAFETY GLASS SIGN VENDOR TO PROVIDE ONE-WAY VISIBILITY FILM ON GLASS LITE. 121 AB F - GATE 3'-0" 3'-2" 1 3/4" VERIFY SOLID CORE WOOD PL-3 N/A N/A 11 N/A N/A N/A N/A N/A -- 120 BM E - DEMOUNTABLE SYSTEM SLIDING DOOR 3'-8" 8'-8" 1 3/4"ALUMINIUM / TEMPERED GLASS PREFINISHED ALUMINIUM EBONY 10 N/A N/A N/A N/A 1/4" TEMPERED SAFETY GLASS TEKNION ALTOS SYSTEM DOORS & HARDWARE PROVIDED BY FURNITURE VENDOR. SEE SHOP DRAWINGS BY FURNITURE VENDOR. GC TO PREP OPENING FOR ALTOS WALL SYSTEM. 119 COUPON BOOTH C - FLUSH W 1/4" TEMPERED SAFETY GLASS FULL LITE 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 07 3/A-600 4/A-600 N/A N/A 1/4" TEMPERED SAFETY GLASS -- 118 VAULT STORAGE A - FLUSH 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 04 3/A-600 4/A-600 N/A N/A N/A GRAY SHADE MEANS NOT USED. 117 SD VAULT EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING TO REMAIN. 115 JANITOR CLOSET A - FLUSH 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 08 3/A-600 4/A-600 N/A N/A N/A -- 114 RESTROOM A - FLUSH 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 06 3/A-600 4/A-600 N/A N/A N/A -- 113 RESTROOM A - FLUSH 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 06 3/A-600 4/A-600 N/A N/A N/A 111 COAT CLOSET A - FLUSH 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 09 3/A-600 4/A-600 N/A N/A N/A CONFIRM HINGED OR BIFOLD DOOR TYPE, SINGLE OR PAIR DOORS, FRAMED OR FRAMELESS INSTALLATION. 110 STAFF ROOM A - FLUSH 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 04 3/A-600 4/A-600 N/A N/A N/A -- 109 MEETING ROOM E - DEMOUNTABLE SYSTEM SLIDING DOOR 3'-8" 8'-8" 1 3/4" ALUMINUM / TEMPERED GLASS PREFINISHED ALUMINUM EBONY 10 N/A N/A N/A N/A 1/4" TEMPERED SAFETY GLASS TEKNION ALTOS SYSTEM DOORS & HARDWARE PROVIDED BY FURNITURE VENDOR. SEE SHOP DRAWINGS BY FURNITURE VENDOR. GC TO PREP OPENING FOR ALTOS WALL SYSTEM. 108 CMR.4 E - DEMOUNTABLE SYSTEM SLIDING DOOR 3'-8" 8'-8" 1 3/4" ALUMINIUM / TEMPERED GLASS PREFINISHED ALUMINIUM EBONY 10 N/A N/A N/A N/A 1/4" TEMPERED SAFETY GLASS TEKNION ALTOS SYSTEM DOORS & HARDWARE PROVIDED BY FURNITURE VENDOR. SEE SHOP DRAWINGS BY FURNITURE VENDOR. GC TO PREP OPENING FOR ALTOS WALL SYSTEM. 106 CMR.3 E - DEMOUNTABLE SYSTEM SLIDING DOOR 3'-8" 8'-8" 1 3/4" ALUMINIUM / TEMPERED GLASS PREFINISHED ALUMINIUM EBONY 10 N/A N/A N/A N/A 1/4" TEMPERED SAFETY GLASS TEKNION ALTOS SYSTEM DOORS & HARDWARE PROVIDED BY FURNITURE VENDOR. SEE SHOP DRAWINGS BY FURNITURE VENDOR. GC TO PREP OPENING FOR ALTOS WALL SYSTEM. 105B ATM / LAN ROOM G - CAGE DOOR SYSTEM 3'-0" 7'-3 1/4" 1 1/4" STEEL WIRE PREFINISHED STEEL PREFINSHED 05 (SIM.) N/A N/A N/A N/A N/A STANDARD GRAY FINISH. SINGLE HINGED DOOR WITH CYLINDRICAL LEVER LOCK. SEE ELEVATION FOR DETAILS. PROVIDE STOREROOM LOCKSET PER HARDWARE TYPE 5. 105A ATM / LAN ROOM A - FLUSH 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 04 3/A-600 4/A-600 N/A N/A N/A -- 104 WORK ROOM A - FLUSH 3'-0" 7'-0" 1 3/4" SOLID CORE WOOD PT-1 HM PT-1 04 3/A-600 4/A-600 N/A N/A N/A -- 101B BANKING HALL EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING (SEE NOTES)N/A N/A N/A EXISTING EXISTING PROVIDE DOOR PULL (SEE HARDWARE 02) AND REPLACE DOOR LOCKING HARDWARE AS NEEDED FOR DOORS TO BE USED AS A SECONDARY ENTRANCE DURING BUSINESS HOURS. GC TO REPLACE STOREFRONT DOORS TO MATCH EXISTING IF HARDWARE CAN'T BE REPLACED. 101A BANKING HALL D - FLUSH W 1/4" TEMPERED SAFETY GLASS FULL LITE (DOUBLE DOORS)6'-0" 7'-0" 1 3/4" ALUMINUM / TEMPERED GLASS PRE FINISHED ALUMINUM PREFINISHED 02 6/A-300 11/A-501 - N/A 1/4" TEMPERED SAFETY GLASS 100 COMMON VESTIBULE EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING W H T MATERIAL FINISH MATERIAL FINISH HEAD JAMB SILL DOOR NUMBER ROOM NAME TYPE TYPICAL SIZE DOOR FRAME HARDWARE DETAILS FIRE LABEL GLAZING NOTES DOOR SCHEDULE 3/8" = 1'-0"WINDOW / STOREFRONT TYPES 1 3/8" = 1'-0"DOOR TYPES 7 SCALE NOTES: 1. SEE GLASS FILM APPLICATION DETAILS, SHEET A-601. 2. GC TO PROVIDE SAMPLES OF STOREFRONT FINISH AND OF ANY NEW MULLIONS REQUIRED AT INFILL OR EXISTING CURTAIN WALL FOR ARCHITECT'S REVIEW AND APPROVAL. A VESTIBULE STOREFRONT W 3/8" TEMPERED SAFETY GLAZING 12'-5" VIF 10'-0" VIF 3/8" ALUMINIUM MATCH EXIST. ADJACENT STOREFRONT 5/A-600 11/A-501 WALL TYPE "SF2". KAWNEER TRIFAB VERSAGLAZE 450 FRAMING SYSTEM, 2" SIGHTLINE, 4 1/2" MULLION DEPTH. BMO VENDOR TO PROVIDE AND INSTALL GLAZING FILM. W H T MATERIAL FINISH HEAD / SILL JAMB WINDOW NUMBER ROOM NAME WINDOW / GLAZING TYPE TYPICAL SIZE FRAME DETAILS NOTES WINDOW AND GLAZING SCHEDULE SCALE SCALE SCALE SCALE SCALE 1/2" = 1'-0"FRAME TYPES 2 SCALE 3" = 1'-0"HM FRAME - HEAD AT GYP. BD. 33" = 1'-0"HM FRAME - JAMB AT GYP. BD. 4 3" = 1'-0"STOREFRONT - HEAD / SILL AT GYP. BD. 53" = 1'-0"STOREFRONT - HEAD AT GYP. BD. 6 1 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 1 LL 10/28/2024 3'- 7 " AT A D A L OC A T I O N S 5' - 0 " A T S T A N D A R D L O C A T I O N S EQ EQ 5'- 0 " MA X . T O B. O . H I G H ES T R A I S ED C H A R AC T E R S 4'- 0 " M I N . T O B . O . L O W E S T R A I S E D C H A R A C T E R S DOOR SCOPE WHERE PRESENT SCHEDULED HARDWARE ROOM SIGNAGE BY BMO VENDOR 9" TY P . A L L D O O RS 34 " M I N . 44 " M A X C A L I F O R N I A AT C YP E R L O CK S 37 " L E V E R H E I G H T TYP. OFFICE FRONT ELEVATION: 1. GLAZING FILM TO BE PROVIDED AND INSTALLED BY BMO VENDOR. 2. APPLY GRADIENT FILM WITH CLEAR AT TOP. VESTIBULE DOOR ELEVATION: 1. GLAZING FILM TO BE PROVIDED AND INSTALLED BY BMO VENDOR. 2. APPLY GLAZING FILM FROM INTERIOR. 10 " 3'- 9 " EQ 5' - 0 " EQ COUPON BOOTH DOOR ELEVATION: 1. GLAZING FILM TO BE PROVIDED AND INSTALLED BY BMO VENDOR. GF-2 10" TYP. 4'- 5 " 2" GF-3 MEETING ROOM ELEVATION: 1. GLAZING FILM TO BE PROVIDED AND INSTALLED BY BMO VENDOR. 2. APPLY GLAZING FILM FROM INTERIOR. 2'- 6 " 11 " 1" 3' - 0 " GF-14 GF-10 GF-1A GF-1B TEKNION DEMOUNTABLE ALTOS SYSTEM PROVIDED AND INSTALLED BY FURNITURE VENDOR. GF-12 GF-2 T T T T T T T T T T T VI F T T T T = TEMPERED 1. ALL DOOR OPENINGS SHALL HAVE A CLEAR OPENING WIDTH OF 32" MINIMUM. CLEAR OPENING WIDTH SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND STOP, WITH THE DOOR OPEN 90 DEGREES. THERE SHALL BE NO PROJECTION INTO REQUIRED CLEAR OPENING WIDTH LOWER THAN 34" ABOVE FLOOR OR GROUND. PROJECTIONS INTO CLEAR OPENING WIDTH BETWEEN 34" AND 80" ABOVE FLOOR OR GROUND SHALL NOT EXCEED 4". [11B-1010.1.1 AND 11B-1010.1.1.1] 2. DOORS SHALL BE PROVIDED WITH REQUIRED MANEUVERING CLEARANCES SHOWN ON SHEET G-103. 3. IF PROVIDED, ALL THRESHOLDS AT DOORWAYS SHALL BE 1/2" MAXIMUM IN HEIGHT PROVIDED THAT THE THRESHOLD HAS A BEVELED EDGE ON EACH SIDE WITH A MAXIMUM SLOPE OF 1:2 FOR THE HEIGHT EXCEEDING 1/4". [11B-404.2.5] 4. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. [11B-309.4] 5. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL BE 34" MINIMUM AND 44" MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. [11B-404.2.7] 6. DOOR AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR OR GATE TO AN OPEN POSITION OF 12 DEGREES FROM THE LATCH SHALL BE 5 SECONDS MINIMUM. [11B-404.2.8.1] 7. DOOR AND GATE OPENING FORCE: THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL BE AS FOLLOWS: 1. INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAXIMUM. 2. SLIDING OR FOLDING DOORS: 5 POUNDS MAXIMUM. 3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 5 POUNDS. 4. EXTERIOR HINGED DOORS: 5 POUNDS MAXIMUM. EXCEPTION: WHEN AT A SINGLE LOCATION, ONE OF EVERY EIGHT EXTERIOR DOOR LEAFS, OR FRACTION OF EIGHT, IS A POWERED DOOR, OTHER EXTERIOR DOORS AT THE SAME LOCATION, SERVING THE SAME INTERIOR SPACE, MAY HAVE A MAXIMUM OPENING FORCE OF 8.5 POUNDS. THE POWERED LEAF(S) SHALL BE LOCATED CLOSEST TO THE ACCESSIBLE ROUTE. [11B-404.2.9] 8. SWINGING DOOR AND GATE SURFACES WITHIN 10" OF FINISHED FLOOR OR GROUND, MEASURED VERTICALLY, SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. (EXCEPTION: SLIDING DOORS). [11B-404.2.10] 9. DOORS, GATES, AND SIDELITES ADJACENT TO DOORS OR GATES CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING THROUGH GLAZED PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE PANEL LOCATED 43" MAXIMUM ABOVE THE FLOOR. [11B-404.2.11] 10. EGRESS DOORS SHALL BE OF THE SIDE-HINGED SWING DOOR, PIVOTED DOOR, OR BALANCED DOOR TYPES. SIDE-HINGED SWINGING DOORS, PIVOTED DOORS AND BALANCED DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM OR AREA CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR GROUP H OCCUPANCY. [1010.1.2 AND 1010.1.2.1] 11. THE UNLATCHING OF ANY DOOR OR LEAF FOR EGRESS SHALL REQUIRE NOT MORE THAN ONE MOTION IN A SINGLE LINEAR OR ROTATIONAL DIRECTION TO RELEASE ALL LATCHING AND LOCKING DEVICES. [11B-1010.2.1] 12. CLOSET DOORS THAT LATCH IN A CLOSED POSITION SHALL BE OPENABLE FROM INSIDE OF CLOSET. [11B-1010.2.6] 13. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. [11-B1010.2] 14. GC SHALL PROVIDE ALL KEYS AT COMPLETION OF EACH PHASE OF CONSTRUCTION. 15. MOUNT CLOSERS ON ROOM SIDE OF DOORS, TYP. UNO. 16. A READILY VISIBLE SIGN SHALL BE POSTED ON EGRESS SIDE ON OR ADJACENT TO EACH VESTIBULE AND ENTRANCE DOOR THAT STATES "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". SIGN SHALL BE IN LETTERS 1" HIGH ON CONTRASTING BACKGROUND. [111B-1010.2.4] 17. POWER-ASSISTED SWINGING DOORS AND LOW-ENERGY POWER-OPERATED SWINGING DOORS SHALL COMPLY WITH BHMA A156.19 [11B-1010.3.2] CODE AND ACCESSIBILITY NOTES -DOOR AND HARDWARE (CA OPTION) 1. GC SHALL FURNISH ALL HARDWARE AS SPECIFIED. PROVIDE CUT SHEETS FOR REVIEW AND APPROVAL BY ARCHITECT. 2. ALL PERMANENT CYLINDERS TO BE PROVIDED BY GC. GC TO COORDINATE WITH CLIENT PROJECT MANAGER FOR CYLINDER TYPE, BRAND, KEYING,ETC. 3. MAIN DOORS (I.E. ENTRANCE DOORS, VESTIBULE DOORS, SECURITY GRILLE DOORS, REAR DOORS) SHALL ALL BE KEYED THE SAME. PROVIDE 30 KEYS. 4. PROVIDE TRILOGY DIGITAL KEYPAD AND SCHLAGE CYLINDER / CORE AT THE FOLLOWING ROOMS: ATM ROOM, EMPLOYEE ENCLAVE, WORKROOMS, STAFF ROOM. EMERGENCY KEY MAY BE KEYED THE SAME FOR ALL DOORS. PROVIDE 2 KEYS. 5. LAN ROOM SHALL BE KEYED UNIQUE. PROVIDE 2 KEYS. 6. JANITOR CLOSET SHALL BE KEYED UNIQUE. PROVIDE 2 KEYS. 7. PROVIDE OCCUPANCY INDICATOR LOCK WITH ADA THUMBTURN AT RESTROOMS. EMERGENCY KEY MAY BE KEYED THE SAME FOR ALL DOORS. PROVIDE 2 KEYS. 8. OFFICE DOORS SHALL NOT BE PROVIDED WITH LOCKS. GENERAL LOCK AND KEY NOTES LEGEND -DOOR HARDWARE SCHEDULE NOT USED SEE DOOR SCHEDULE 3'-0" TYP. UNO 4" TYP. UNO THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 DOOR HARDWARE SCHEDULE AND DETAILS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-601 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE SCALE 1/2" = 1'-0"TYP. DOOR HARDWARE AND SIGNAGE 2 3/8" = 1'-0"FILM APPLICATION AT GLASS DOORS 1 NOTES: CLOSERS SHALL BE MOUNTED ON THE INSIDE OF THE ROOM. USE PARALLEL ARM CLOSER ON PUSH SIDE, AND REGULAR ARM CLOSER ON THE PULL SIDE OF DOOR. 11A TELLER LINE (DOUBLE HINGED)1 DOUBLE ACTION SPRING HINGE SUGATSUNE JDAW-180-35A DARK BRONZE ANODIZED DESIGNER NOTE: CONFIRM FINISH. USE ONLY AT DOORS WHICH REQUIRE DOUBLE-ACTING SPRING HINGES AND NO LATCHING HARDWARE IN ORDER TO REDUCE ADA CLEARANCES AT TELLER LINE DOORS. ALL OTHER DOORS TO USE HARDWARE SET 11. 1 PASSAGE SET SCHLAGE ALX 10 626 SATIN CHROME RHODES LEVER (RHO) 11 TELLER LINE 1 CONTINUOUS PIANO HINGE ASSA ABLOY MARKER FM 100 DARK BRONZE ANODIZED 10 OFFICE DEMOUNT. PARTITIONS 1 ADA-COMPLIANT ACCESSABLE SLIDING OR HINGED DOOR HARDWARE PROVIDED AND INSTALLED BY BMO VENDOR 2 DOOR PULL RICHELIEU BP56325128195 BRUSHED NICKEL 5 5/16" OVERALL LENGTH, 5 1/32" CENTER-TO-CENTER. ADA COMPLIANT. 1 BIFOLD DOOR HARDWARE KIT - 72" L RICHELIEU 14028WBC 72" TRACK LENGTH. PROVIDE ADA-COMPLIANT HARDWARE (SEE BELOW). DESIGNER NOTE: CONFIRM DOOR OPENING WIDTH AND ADJUST SPECIFICATION AS NEEDED. 09B CLOSET / STORAGE - DOUBLE BIFOLD 6 BIFOLD HINGE RICHELIEU 832 185 SATIN NICKEL 1 DOOR PULL RICHELIEU BP56325128195 BRUSHED NICKEL 5 5/16" OVERALL LENGTH, 5 1/32" CENTER-TO-CENTER. ADA COMPLIANT. 1 BIFOLD DOOR HARDWARE KIT - 36" L RICHELIEU 14014WBC 36" TRACK LENGTH. PROVIDE ADA-COMPLIANT HARDWARE (SEE BELOW). DESIGNER NOTE: CONFIRM DOOR OPENING WIDTH AND ADJUST SPECIFICATION AS NEEDED.09A CLOSET / STORAGE - BIFOLD 3 BIFOLD HINGE RICHELIEU 832 185 SATIN NICKEL 3 PER LEAF SILENCERS ROCKWOOD 608-RKW GRAY 1 DOOR STOP BURNS 521 US26D SATIN CHROME 1 PASSAGE SET SCHLAGE ALX 10 626 SATIN CHROME RHODES LEVER (RHO).09 COAT CLOSET / STORAGE - HINGED 3 BUTT HINGES MCKINNEY TA2714 NRP US26D SATIN CHROME 3 PER LEAF SILENCERS ROCKWOOD 608-RKW GRAY 2 KICK PLATE BURNS KP50 US32D STAINLESS STEEL 12" HIGH. PROVIDE ONE KICKPLATE ON EACH SIDE OF DOOR. 1 SURFACE CLOSER NORTON 7500 689 ALUMINIUM MOUNT ON ROOM SIDE OF DOOR - NOT CORRIDOR SIDE. 1 DOOR STOP BURNS 521 US26D SATIN CHROME 1 STOREROOM LOCKSET SCHLAGE ALX 80 626 SATIN CHROME RHODES LEVER (RHO) 08 JANITOR CLOSET 3 BUTT HINGES MCKINNEY TA2714 NRP US26D SATIN CHROME 3 PER LEAF SILENCERS ROCKWOOD 608-RKW GRAY 1 SURFACE CLOSER NORTON 7500 689 ALUMINIUM MOUNT ON ROOM SIDE OF DOOR - NOT CORRIDOR SIDE. 1 DOOR STOP BURNS 521 US26D SATIN CHROME 1 CYLINDER PRIVACY LOCKSET SCHLAGE ALX 40 626 SATIN CHROME RHODES LEVER (RHO) 07 COUPON BOOTH 3 BUTT HINGES MCKINNEY TA2714 NRP US26D SATIN CHROME 3 PER LEAF SILENCERS ROCKWOOD 608-RKW GRAY 2 KICK PLATE BURNS KP50 US32D STAINLESS STEEL 12" HIGH. PROVIDE ONE KICKPLATE ON EACH SIDE OF DOOR. 1 SURFACE CLOSER NORTON 7500 689 ALUMINIUM MOUNT ON ROOM SIDE OF DOOR - NOT CORRIDOR SIDE. 1 DOOR STOP BURNS 521 US26D SATIN CHROME 1 MORTISE PRIVACY LOCKSET W/ OCCUPANCY INDICATOR SCHLAGE L9496P 06A 626 SATIN CHROME 06 RHODES LEVER, 09-544 ADA THUMBTURN AT OCCUPANCY INDICATOR, "VACANT" / "OCCUPIED" INDICATOR TEXT 06 RESTROOMS 3 BUTT HINGES MCKINNEY TA2714 NRP US26D SATIN CHROME 2 KICK PLATE BURNS KP50 US32D STAINLESS STEEL 12" HIGH. PROVIDE ONE KICKPLATE ON EACH SIDE OF DOOR. 3 PER LEAF SILENCERS ROCKWOOD 608-RKW GRAY 1 SURFACE CLOSER NORTON 7500 689 ALUMINIUM 1 OVERHEAD DOOR STOP GLYNN-JOHNSON 410S US26D SATIN CHROME GC TO VERIFY COMPATIBILITY. 1 STOREROOM LOCKSET SCHLAGE L9080 P 06A S123 626 SATIN CHROME 06 RHODES LEVER 05 LAN / ELECTRICAL ROOM 3 BUTT HINGES MCKINNEY TA2714 NRP US26D SATIN CHROME 2 KICK PLATE BURNS KP50 US32D STAINLESS STEEL 12" HIGH. PROVIDE ONE KICKPLATE ON EACH SIDE OF DOOR. 3 PER LEAF SILENCERS ROCKWOOD 608-RKW GRAY 1 DOOR SCOPE IPI DOORSCOPE DS2000 ALUMINIUM / SILVER USE AT ATM ROOM DOOR ONLY. SEE DETAIL FOR MOUNTING HEIGHT. 1 SURFACE CLOSER NORTON 7500 689 ALUMINIUM MOUNT ON ROOM SIDE OF DOOR - NOT PUBLIC SIDE. 1 DOOR STOP BURNS 521 US26D SATIN CHROME 1 CYLINDER LOCKSET SCHLAGE BY GC 626 SATIN CHROME TO BE INSTALLED IN TRILOGY LOCK ABOVE. CONFIRM CORE SPECIFICATION WTIH ARCHITECT AND PROJECT MANAGER PRIOR TO PURCHASE AND INSTALLATION. 1 ELECTRONIC KEYLESS ACCESS LOCK ALARM LOCK SYSTEMS TRILOGY T2 DL2700ICS US26D SATIN CHROME 04 EMPLOYEE ENCLAVE, WORK / PRINT ROOM, ATM ROOM, STAFF ROOM 3 BUTT HINGES MCKINNEY TA2714 NRP US26D SATIN CHROME 1 RAIN GUARD PEMKO 346C (FRAME WIDTH) CLEAR ANODIZED ALUMINIUM 1 GASKETING PEMKO 2891AS (HEAD) 290AS (JAMBS) MILL FINISH ALUMINIUM 1 SWEEP PEMKO 315CN CLEAR ANODIZED ALUMINIUM 1 THRESHOLD PEMKO 253 X 3AFG MILL FINISH ALUMINIUM 1 CLOSER NORTON UNI7500 689 ALUMINIUM 1 DOOR POSITION SWITCH SECURITRON DPS-M GRAY CONFIRM WITH BMO SECURITY DRAWINGS IF REQUIRED. CONFIRM SPECIFICATION WITH ARCHITECT, PROJECT MANAGER, AND CLIENT SECURITY CONTRACTOR PRIOR TO PURCHASE AND INSTALLATION. 1 MORTISE EXIT LOCKSET SCHLAGE L9080/C123 626 SATIN CHROME RHODES ADA LEVER STYLE. DESIGNER NOTE: CONFIRM WHETHER EXTERIOR HARDWARE AND EXTERIOR KEYWAY REQUIRED. 03 EXTERIOR EXIT DOOR 3 CONTINUOUS HINGE PEMKO CFM SLF-HD1 x DR HT PE CLEAR ANODIZED ALUMINIUM 1 CLOSER NORTON UNI7500 BLACK FIELD VERIFY TO MATCH EXISTING 2 CONCEALED OVERHEAD STOP RIXON 6-X36 BLACK FIELD VERIFY TO MATCH EXISTING 1 RIM CYLINDER SCHLAGE 20-001 / C123 BLACK FIELD VERIFY TO MATCH EXISTING 2 SEAL PEMKO 297BLS BLACK FIELD VERIFY TO MATCH EXISTING 2 SWEEP PEMKO 18061BSPNB BLACK FIELD VERIFY TO MATCH EXISTING 1 PER LEAF PUSH BAR ROCKWOOD RM350 MTG-TYPE 6HD BSP FIELD VERIFY TO MATCH EXISTING 1 PER LEAF OFFSET PULL ROCKWOOD RM3331-165 MTG-TYPE 6HD BSP FIELD VERIFY TO MATCH EXISTING 1 PER LEAF CONTINUOUS HINGE PEMKO BSPFM SLF-HD1 x DR HT PE BLACK FIELD VERIFY TO MATCH EXISTING 1 MORTISE DEADLOCK ADAMS RITE MS1850S 335 BLACK 2 FULL LENGTH ADA PUSH PLATE ACTUATOR LCN 8310-836TW SATIN STAINLESS STEEL 36" x 6" FULL LENGTH ACTUATOR, WALL MOUNTED. NO EXPOSED WHIPS PERMITTED. SEE POWER AND DEVICE PLAN FOR LOCATION. (1) INSIDE BANKING HALL, (1) INSIDE BUILDING VESTIBULE 1 KEY SWITCH SCHLAGE 653-04, NS CYL BLACK MOUNTED TO MULLION AT 44" AFF INSIDE BANKING HALL. NO EXPOSED WHIPS PERMITTED. 02 MAIN ENTRANCE 1 AUTOMATIC DOOR OPERATOR LCN 4640 SERIES BLACK PROVIDE KEY OVERRIDE SWITCH. FIELD VERIFY TO MATCH EXISTING. 2 CONCEALED OVERHEAD STOP RIXON 6-X36 630 1 CLOSER NORTON UNI7500 BLACK DESIGNER NOTE: MATCH COLOR TO FRAME IF NOT BLACK OR DARK BRONZE. USE ON LEAF WITHOUT AUTO DOOR OPENER. 1 RIM CYLINDER SCHLAGE 20-001 / C123 626 SATIN CHROME DESIGNER NOTE: VERIFY IF THERE IS AN EXISTING ONE, NEED FOR NEW DOOR. 1 PER LEAF PUSH BAR ROCKWOOD RM350 MTG-TYPE 1XH MATCH STOREFRONT 1 PER LEAF OFFSET PULL ROCKWOOD RM3331-16 MTG-TYPE 6HD MATCH STOREFRONT 1 DUST PROOF STRIKE PEMKO 570 2 MANUAL FLUSH BOLT ROCKWOOD 555 / 557 (AS REQUIRED) US26D SATIN CHROME 2 CONTINUOUS HINGE PEMKO CFM SLF-HD1 x DR HT PE US26D SATIN CHROME 1 STATUS INDICATOR ADAMS RITE 4089-00 1 MORTISE DEADLOCK ADAMS RITE MS1850S 335 BLACK DESIGNER NOTE: VERIFY IF ONE ALREADY EXISTIS IN GOOD WORKING ORDER. 1 4x4 ADA DOOR PUSH PLATE ACTUATOR LCN 8310-3853TWB ACTUATOR 8310-865 RECEIVER SATIN STAINLESS STEEL FLUSH MOUNTED, CONFIRM HARDWIRED OR WIRELESS INSTALLATION, SEE POWER AND DEVICE PLAN FOR LOCATION. WIRELESS INSTALLATION REQUIRES AA BATTERIES. DESIGNER NOTE: VERIFY IF ONE ALREADY EXISTS IN GOOD WORKING ORDER, LOCATE ON EGRESS AND POWER / DEVICE PLANS AND SHOW ADA CLEARANCES. 01 EXTERIOR ENTRANCE - PAIR 1 AUTOMATIC DOOR OPERATOR LCN 4640 SERIES 695 DARK BRONZE PROVIDE KEY OVERRIDE SWITCH. DESIGNER NOTE: VERIFY IF ONE ALREADY EXISTS IN GOOD WORKING ORDER, MATCH FINISH TO ALUMINUM DOORS AND VERIFY SINGLE OR PAIR. GROUP QTY COMPONENT MANUFACTURER MODEL FINISH NOTES DOOR HARDWARE SCHEDULE 1" = 1'-0"TYP. DOOR AT ADJACENT WALL 3 SCALE ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 1 1 LL 10/28/2024 LEGEND -SCHEDULES NOT USED NOTE:REFER TO CONTACTS ON COVER SHEET. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 FINISH SCHEDULE BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-602 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 PT-7 ACCENT WALL PAINT MILLWORK NICHES, MEDIA SLAT WALL SOFFIT MANUFACTURER: BENJAMIN MOORE COLOR: BLACK 2132-10 FINISH: EGGSHELL PT-6 ACCENT WALL PAINT REFER TO FINISH PLAN AND ELEVATIONS FOR LOCATION MANUFACTURER: BENJAMIN MOORE COLOR: BLUEBELLE 2064-60 FINISH: EGGSHELL PT-5 ACCENT WALL PAINT REFER TO FINISH PLAN AND ELEVATIONS FOR LOCATION MANUFACTURER: BENJAMIN MOORE COLOR: CUMULUS COTTON 2063-79 FINISH: EGGSHELL PT-4 ACCENT WALL PAINT REFER TO FINISH PLAN AND ELEVATIONS FOR LOCATION MANUFACTURER: SHERWIN WILLIAMS COLOR: SW6959 BLUE CHIP FINISH: EGGSHELL PT-3 ACCENT WALL PAINT ACCENT PAINT IN RETAIL OFFICES WITHOUT WINDOWS OR IN LIEU OF ACCENT WALLCOVERING MANUFACTURER: BENJAMIN MOORE COLOR: WHITE SATIN 2067-70 FINISH: EGGSHELL PT-2 GENERAL CEILING PAINT CEILING PAINT MANUFACTURER: BENJAMIN MOORE COLOR: WHITE OC-151 FINISH: TEXTURED FINISH PT-1 GENERAL WALL FINISH GENERAL PAINT FINISH (ALL WALLS, DOORS, AND FRAMES UNLESS NOTED OTHERWISE) MANUFACTURER: SHERWIN WILLIAMS COLOR: SW6252 ICE CUBE FINISH: EGGSHELL (WALLS); SEMI-GLOSS (DOORS AND FRAMES) FRP FIBERGLASS REINFORCED PLASTIC PANELS JANITOR'S CLOSET (ONLY WHERE APPROVED BY BMO) MANUFACTURER: MARLITE OR APPROVED EQUAL PRODUCT: STANDARD FRP WITH PEBBLED FINISH COLOR: P100 WHITE NOTES: PROVIDE STAIN ANODIZED ALUMINUM TRIM AT TOP ACM-1 ALUMINIUM COMPOSITE PANEL - BLUE ATM VESTIBULE ACCENT WALL MANUFACTURER: ALPOLIC PE OR APPROVED EQUAL PRODUCT: ALPOLIC PE SIZE: THREE EQUAL PANELS, SEE ELEVATION AND DETAILS. COLOR: MBU BLUE / TO MATCH PMS 300 C WALLCOVERING / WALL TILE / PAINT / ACM ACM-2 ALUMINIUM COMPOSITE PANEL - GRAY ATM VESTIBULE ACCENT WALL BASE MANUFACTURER: ALPOLIC PE OR APPROVED EQUAL PRODUCT: ALPOLIC PE SIZE: +/- 6 3/4" H, SEE ELEVATION. COLOR: TO MATCH PPG 0996-6 SLATE MINE TB-1 TILE BASE RESTROOMS, JANITOR CLOSET MANUFACTURER: OLYMPIA TILE COLLECTION: UPTOWN SERIES COLOR: MANHATTAN FINISH: MATTE SIZE: 4" HIGH NOTE: SEE T-1 FOR GROUT COLOR. TILE BASE TO BE PROVIDED ON ALL WALLS EXCEPT WET WALL WITH WALL TILE. PROVIDE SCHLUTER SCHIENE TRIM; SATIN ANODIZED ALUMINUM FINISH. T-1 TO BE CUT INTO 4"X24" STRIPS. RB-2 RUBBER WALL BASE AT MEDIA SLAT WALL ONLY MANUFACTURER: MOHAWK GROUP COLLECTION: ELEMENTAL EDGES COLOR: 002 NIGHT SKIES SIZE: 4" x 1/8"; PROVIDE COVE BASE ALL CARPET AND HARD SURFACE FLOORING APPLICATIONS. RB-1 RUBBER WALL BASE GENERAL WALL BASE FOR ALL ROOMS EXCEPT FOR TILE MANUFACTURER: MOHAWK GROUP COLLECTION: ELEMENTAL EDGES COLOR: 053 DOVE SIZE: 4" x 1/8"; PROVIDE COVE BASE ALL CARPET AND HARD SURFACE FLOORING APPLICATIONS. WALL BASE ST STAIR TREAD STAIRS MANUFACTURER: MOHAWK GROUP COLLECTION: ELEMENTAL EDGES STYLE: CRS07 ROUND PROFILE WITH VISUAL STRIP COLOR: 002 NIGHT SKIES SIZE: 12 1/2" x 48" INSTALLATION: PROVIDE CRS09 RISER TRIM AT BOTH SIDES OF STAIRS, COLOR 053 DOVE. VCT-2 ANTI-STATIC VCT LAN ROOM MANUFACTURER: ARMSTRONG FLOORING COLLECTION: EXCELON SDT STATIC CONTROL FLOORING COLOR: FOSSIL GREY 51956 SIZE: 12"X12" INSTALL METHOD: QUARTER-TURN VCT-1A VCT (ALTERNATE) STAFF WORKROOM, STORAGE, ATM ROOM MANUFACTURER: TARKETT COLLECTION: VCT II COLOR: 522 STEEL WORKS SIZE: 12"X12" INSTALL METHOD: QUARTER-TURN VCT-1 VCT STAFF WORKROOM, STORAGE, ATM ROOM MANUFACTURER: ARMSTRONG FLOORING COLLECTION: STANDARD EXCELON IMPERIAL TEXTURE COLOR: CHARCOAL 51915 SIZE: 12"X12" INSTALL METHOD: QUARTER-TURN T-1 PORCELAIN FLOOR TILE RESTROOMS, JANITOR CLOSET MANUFACTURER: OLYMPIA TILE COLLECTION: UPTOWN SERIES COLOR: MANHATTAN FINISH: MATTE SIZE: 12" x 24" INSTALL METHOD: 1/3 OFFSET GROUT: LATICRETE 09 FROSTY SC SEALED CONCRETE JANITOR CLOSET (ONLY WHERE APPROVED BY BMO) SPEC TBD LVT LUXURY VINYL TILE STAFF ROOM MANUFACTURER: MOHAWK GROUP COLLECTION: LIVING LOCAL STYLE: WOOD COLOR: 560 BISQUE WARE SIZE: 7.72" x 51.97" INSTALL METHOD: REFER TO INSTALLATION DIAGRAM BY MOHAWK. NOTES: TO BE INSTALLED WITH ONE OF THE FOLLOWING ADHESIVES - M95.0 RESILIENT FLOORING ADHESIVE, M99 RESILIENT FLOORING ADHESIVE, OR M700 ADHESIVE. REFER TO INSTALLATION DIAGRAM BY MOHAWK. M-1 PEDIMAT ENTRANCE MANUFACTURER: CONSTRUCTION SPECIALTIES COLLECTION: PEDISYSTEMS ENTRANCE FLOORING PRODUCT: PEDITRED G3 COLOR: 9332 ANTHRACITE NOTE: REFER TO INTERIOR DETAILS AND FINISH PLAN FOR MORE INFORMATION. QM QUEUING MAT BANKING HALL QUEUING MAT MANUFACTURER: SOURCE FLOOR + SPECIALTIES, INC MATERIAL: GRIZZLY FX FIELD COLOR: EBONY INLAY COLOR: PEARL GRAY (FOR CHEVRONS) EDGING: HEAVY EDGE; COLOR = BLACK SIZE: 30"X120" NOTE: THIS IS A MAT THAT SITS ON TOP OF CPT-1 CPT-6 CARPET BANKING HALL, LOUNGE AREA, OFFICES, MEETING ROOMS (FOR REFRESH PROJECT ONLY) MANUFACTURER: SHAW CONTRACT COLLECTION: HAND DRAWN PRODUCT: STIPPLE TILE 5T116 COLOR: GRAPHITE 13510 SIZE: 16"X36" INSTALL METHOD: BRICK ASHLAR CPT-5 CARPET TILE ENTRANCE VESTIBULE (ONLY WHERE DIRECTED BY BMO) MANUFACTURER: SHAW CONTRACT COLLECTION: STEPPIN OUT PRODUCT: WELCOME II TILE 5T031 COLOR: STERLING 31557 SIZE: 24"X24" INSTALL METHOD: QUARTER TURN NOTES: PROVIDE INDOOR / OUTDOOR ADHESIVE CPT-4B CARPET TILE LOUNGE AREA MANUFACTURER: MOHAWK GROUP COLLECTION: ART STYLE PRODUCT: METALLIC PATH COLOR: RSUP 369 (CUSTOM RED TRANSIENT TILE) SIZE: 12"x36" INSTALL METHOD: REFER TO CARPET INSTALLATION DIAGRAM BY MOHAWK. CPT-4A CARPET TILE LOUNGE AREA MANUFACTURER: MOHAWK GROUP COLLECTION: ART STYLE PRODUCT: METALLIC PATH COLOR: RSUP 559 (CUSTOM BLUE TRANSIENT TILE) SIZE: 12"x36" INSTALL METHOD: REFER TO CARPET INSTALLATION DIAGRAM BY MOHAWK. CPT-3A CARPET TILE LOUNGE AREA MANUFACTURER: MOHAWK GROUP COLLECTION: COLOR BALANCE COLOR: 575 NIGHTSHADE (BLUE SOLID TILE) SIZE: 12"x36" INSTALL METHOD: REFER TO CARPET INSTALLATION DIAGRAM BY MOHAWK. CPT-3B CARPET TILE LOUNGE AREA MANUFACTURER: MOHAWK GROUP COLLECTION: COLOR BALANCE COLOR: 373 ATOMIC (RED SOLID TILE) SIZE: 12"x36" INSTALL METHOD: REFER TO CARPET INSTALLATION DIAGRAM BY MOHAWK. CPT-2B CARPET TILE LOUNGE AREA MANUFACTURER: MOHAWK GROUP COLLECTION: ART STYLE PRODUCT: DISRUPTIVE PATH COLOR: 913 ORANGE CRUSH (RED GRADIENT TILE) SIZE: 12"x36" INSTALL METHOD: REFER TO CARPET INSTALLATION DIAGRAM BY MOHAWK. CPT-2A CARPET TILE BANKING HALL, LOUNGE AREA, OFFICES, MEETING ROOM MANUFACTURER: MOHAWK GROUP COLLECTION: ART STYLE PRODUCT: DISRUPTIVE PATH COLOR: 915 BLUE DUSK (BLUE GRADIENT TILE) SIZE: 12"x36" INSTALL METHOD: REFER TO CARPET INSTALLATION DIAGRAM BY MOHAWK. CPT-1 CARPET TILE GENERAL CARPET TILE MANUFACTURER: MOHAWK GROUP COLLECTION: ART STYLE PRODUCT: METALLIC PATH COLOR: 929 PLATINUM GLEAM (NEUTRAL) SIZE: 12"x36" INSTALL METHOD: REFER TO CARPET INSTALLATION DIAGRAM BY MOHAWK. FLOORING AND TRANSITION TAG CATEGORY APPLICATION SPECIFICATION FINISH SCHEDULE PR70X SOLAR CONTROL GLAZING FILM EXTERIOR WINDOWS MANUFACTURER: 3M PRODUCT: PRESTIGE PR 70X NOTES: REFER TO FINISH PLAN FOR LOCATIONS. TO BE APPLIED TO GLAZING EXTERIOR SURFACE. PROVIDED AND INSTALLED BY BMO VENDOR. PR40X SOLAR CONTROL GLAZING FILM EXTERIOR WINDOWS MANUFACTURER: 3M PRODUCT: PRESTIGE PR 40X NOTES: REFER TO FINISH PLAN FOR LOCATIONS. TO BE APPLIED TO GLAZING EXTERIOR SURFACE. PROVIDED AND INSTALLED BY BMO VENDOR. PR20X SOLAR CONTROL GLAZING FILM EXTERIOR WINDOWS MANUFACTURER: 3M PRODUCT: PRESTIGE PR20X NOTES: REFER TO FINISH PLAN FOR LOCATIONS. TO BE APPLIED TO GLAZING EXTERIOR SURFACE. PROVIDED AND INSTALLED BY BMO VENDOR. GF-14 PRIVACY FILM GLASS INTERIOR MANUFACTURER: 3M ID 7100055480 COLOR: 949 WHITE GF-12 ONE-WAY VISIBILITY FILM EMPLOYEE ENCLAVE DOOR MANUFACTURER: 3M PRODUCT: 3635-210 WHITE PERFORATED (FIRST SURFACE), NIGHT VISION 15 (SECOND SURFACE) NOTES: PROVIDED AND INSTALLED BY BMO VENDOR GF-11A PERFORATED GLAZING FILM EXTERIOR WINDOWS MANUFACTURER: 3M PRODUCT: FASARA PRISIM/DOT SH2FGVI, VISTA NOTES: SEE FINISH PLAN FOR LOCATION. APPLIED TO INTERIOR GLAZING SURFACE. TO BE INSTALLED WHEN STOCK IS UNAVAILABLE FOR GF-11. PROVIDED AND INSTALLED BY BMO VENDOR. GF-11 PERFORATED GLAZING FILM EXTERIOR WINDOWS MANUFACTURER: 3M PRODUCT: FASARA PRISIM/DOT SH2FGSK, SHIZUKU COLOR: WHITE NOTES: SEE FINISH PLAN FOR LOCATION. APPLIED TO INTERIOR GLAZING SURFACE. PROVIDED AND INSTALLED BY BMO VENDOR. GF-10 CUSTOM GLAZING FILM OFFICE GLAZING FILM MANUFACTURER: 3M PRODUCT: CUSTOM BMO BLUE TRANSPARENT FILM NOTES: PROVIDED AND INSTALLED BY BMO VENDOR. GF-9 CUSTOM GLAZING FILM WORKSTATIONS MANUFACTURER: 3M PRODUCT: CUSTOM BMO BLUE GLAZING FILM. NOTES: CLEAR BLUE AT TOP, OPAQUE BLUE AT BASE. PROVIDED AND INSTALLED BY BMO VENDOR. GF-6 GLAZING FILM MEETING ROOM DOOR AND GLASS PARTITIONS MANUFACTURER: 3M PRODUCT: FASARA SHUTIE (ONE SIDE), DUSTED CRYSTAL (2ND SIDE) NOTES: PROVIDED AND INSTALLED BY BMO VENDOR. GF-5 SECURITY GLAZING FILM VARIES MANUFACTURER: 3M DISTRIBUTOR: CONVENIENCE GROUP INC. PRODUCT: SCOTCHSHIELD SAFETY & SECURITY WINDOW FILM ULTRA SERIES - ULTRA 800 NOTES: PROVIDED AND INSTALLED BY BMO VENDOR (TBD) GF-3 PRIVACY GLAZING FILM VARIES MANUFACTURER: 3M PRODUCT: FROSTED CRYSTAL 7725SE-324 NOTES: PROVIDED AND INSTALLED BY BMO VENDOR. GF-2 GRADIATED GLAZING FILM - VISIBILITY ENTRY VESTIBULE MANUFACTURER: 3M PRODUCT: FASARA AERINA SH2FG AP ARPA NOTES: PROVIDED AND INSTALLED BY BMO VENDOR. GF-1B GLAZING FILM - VISIBILITY OFFICE DOORS AND FIXED SCREEN MANUFACTURER: 3M PRODUCT: FASARA SH2MAGL, GLACE NOTES: PROVIDED AND INSTALLED BY BMO VENDOR. APPLY 2" STRIP DIRECTLY ABOVE GF-1A. GF-1A GRADIATED GLAZING FILM OFFICE DOORS AND FIXED SCREEN MANUFACTURER: 3M PRODUCT: FASARA AERINA SH2FGAR NOTES: PROVIDED AND INSTALLED BY BMO VENDOR. INSTALL UP TO 4'-5" AFF. APPLY GRADIENT FILM WITH CLEAR AT THE TOP. GLAZING FILM WT-4A GLAZED PORCELAIN WALL TILE (ALTERNATE)STAFF ROOM COUNTER BACKSPLASH DISTRIBUTOR: OLYMPIA TILE PRODUCT: OCEANI SERIES COLOR: BLUE SIZE: 2.5" x 10" FINISH: GLOSSY GROUT: LATICRETE; 42 PLATINUM INSTALLATION METHOD: VERTICAL STACK NOTES: IF TILE EDGES ARE EXPOSED, PROVIDE SCHLUTER JOLLY SATIN NICKEL ANODIZED ALUMINUM 3/8-INCH x 8 FT. 2-1/2-INCH METAL TILE EDGING TRIM OR SIMILAR TO SUIT 4MM DEPTH. WT-4 GLAZED PORCELAIN WALL TILE STAFF ROOM COUNTER BACKSPLASH DISTRIBUTOR: OLYMPIA TILE PRODUCT: GEM SERIES COLOR: COBALTO SIZE: 2.5" x 10" FINISH: GLOSSY GROUT: LATICRETE 42 PLATINUM INSTALLATION METHOD: VERTICAL STACK NOTES: IF TILE EDGES ARE EXPOSED, PROVIDE SCHLUTER JOLLY SATIN NICKEL ANODIZED ALUMINUM 3/8-INCH x 8 FT. 2-1/2-INCH METAL TILE EDGING TRIM OR SIMILAR TO SUIT 4MM DEPTH. WT-2 GLAZED CERAMIC WALL TILE RESTROOM AND JANITOR CLOSET WET WALLS DISTRIBUTOR: OLYMPIA TILE PRODUCT: COLOUR & DIMENSIONS COLOR: ARCTIC WHITE FINISH: BRIGHT SIZE: 4" x 12" INSTALL METHOD: VERTICAL STACK GROUT: LATICRETE 09 FROSTY VW-20 VINYL WALL COVERING COLUMNS IN BANKING HALL MANUFACTURER: KOROSEAL SERIES: SPIRE COLOR: MUSEUM SPR1-05 VW-8 VINYL WALL COVERING LOUNGE AREAS MANUFACTURER: CROWN SURFACE SOLUTIONS SERIES: LEVEL DIGITAL WALLCOVERINGS COLOR: PROVIDED BY BMO - USE ONLY AS DIRECTED BY BMO VW-7 VINYL WALL COVERING WELLNESS ROOM MANUFACTURER: CROWN SURFACE SOLUTIONS SERIES: GAZING PRETENSE COLOR: AREAS EM-5 VW-6A VINYL WALL COVERING (ALTERNATE)MEETING ROOM MANUFACTURER: KOROSEAL DISTRIBUTER: KOROSEAL SERIES: NIWA COLOR: NW21-10 WATER BASIN VW-6 VINYL WALL COVERING MEETING ROOM MANUFACTURER: KOROSEAL DISTRIBUTER: KOROSEAL SERIES: NIWA COLOR: NW21-11 STREAM VW-5A VINYL WALL COVERING (ALTERNATE)COUPON BOOTH MANUFACTURER: VESCOM DISTRIBUTER: KOROSEAL SERIES: AIKIN COLOR: 1068-06 VW-5 VINYL WALL COVERING COUPON BOOTH MANUFACTURER: VESCOM DISTRIBUTER: KOROSEAL SERIES: MILLWOOD COLOR: 1077.14 VW-3A VINYL WALL COVERING (ALTERNATE)ACCENT WALL IN OFFICES MANUFACTURER: VESCOM DISTRIBUTER: KOROSEAL SERIES: MILLWOOD COLOR: 1077.18 VW-3 VINYL WALL COVERING ACCENT WALL IN OFFICES MANUFACTURER: YORK CONTRACT DISTRIBUTER: TBD* SERIES: BROADWICK COLOR: GW2205 VW-2 ACOUSTC VINYL WALL COVERING MEETING NICHE MANUFACTURER: ARTE DISTRIBUTER: KOROSEAL COLLECTION: INTRIGUE PATTERN: ROSACE COLOR: 10554 GREY NOTES: SEE DETAILS FOR TRIM REQUIREMENTS. VB-3 TACK BOARD STAFF ROOM MANUFACTURER: KOROSEAL PRODUCT: TAC-WALL COLOR: 04 STONE SIZE: 4'-0"H x 6'-0"W NOTES: DIRECT GLUE INSTALLATION. PROVIDE J-TRIM FRAME SURROUND IN CLEAR ANODIZED ALUMINUM FINISH. PTS-4 HIGH-TRAFFIC PAINT HIGH TRAFFIC HALLWAYS AND ATM WALLS MANUFACTURER: SCUFFMASTER PRODUCT: SCRUBTOUCH COLOR: TO MATCH PT-4 FINISH: EGGSHELL NOTES: REFER TO MANUFACTURER'S RECOMMENDATION FOR PRIMER AND PAINTING REQUIREMENTS BASED ON SUBSTRATE. PTS-1 HIGH-TRAFFIC PAINT HIGH TRAFFIC HALLWAYS AND ATM WALLS MANUFACTURER: SCUFFMASTER PRODUCT: SCRUBTOUCH COLOR: TO MATCH PT-1 FINISH: EGGSHELL NOTES: REFER TO MANUFACTURER'S RECOMMENDATION FOR PRIMER AND PAINTING REQUIREMENTS BASED ON SUBSTRATE. PT-11 ACCENT WALL PAINT STAFF ROOM MANUFACTURER: BENJAMIN MOORE COLOR: NEWPORT GREEN 2050-30 FINISH: EGGSHELL PT-10 ACCENT WALL PAINT STAFF ROOM MANUFACTURER: BENJAMIN MOORE COLOR: WARM SPRINGS 682 FINISH: EGGSHELL PT-9 ACCENT WALL PAINT REFER TO FINISH PLAN AND ELEVATIONS FOR LOCATION MANUFACTURER: BENJAMIN MOORE COLOR: SYMPHONY BLUE 2060-10 FINISH: EGGSHELL PT-8 ACCENT WALL PAINT REFER TO FINISH PLAN AND ELEVATIONS FOR LOCATION MANUFACTURER: BENJAMIN MOORE COLOR: ATHENS BLUE 797 FINISH: EGGSHELL PT-7A ACCENT WALL PAINT REFER TO FINISH PLAN AND ELEVATIONS FOR LOCATION MANUFACTURER: BENJAMIN MOORE COLOR: SW7645 THUNDER GRAY FINISH: EGGSHELL WALL COVERING / WALL TILE / PAINT TAG CATEGORY APPLICATION SPECIFICATION FINISH SCHEDULE RSH-B ROLLER SHADE - BLACKOUT WHERE INDICATED MANUFACTURER: ELITE PRO SHADING SYSTEMS PRODUCT: BROOKLYN BLACKOUT, WHITE NOTES: PROVIDE WHITE FASCIA RSH-2 ROLLER SHADE - MOTORIZED WHERE INDICATED MANUFACTURER: ELITE PRO SHADING SYSTEMS PRODUCT: PROSILVER ECO PVC FREE, WHITE, 2% OPENNESS NOTES: MOTORIZED; ROOM TO BE PROGRAMMED TO BE IN-SYNC; PROVIDE WHITE FASCIA RSH-1 ROLLER SHADE - MANUAL WHERE INDICATED MANUFACTURER: ELITE PRO SHADING SYSTEMS PRODUCT: PROSILVER ECO PVC FREE, WHITE, 2% OPENNESS NOTES: MANUAL; PROVIDE WHITE FASCIA WINDOW SHADES BPG-2 SPANDREL GLAZING BACKPAINTED GLASS WHERE REQUIRED MANUFACTURER: OPACI-COAT 300 PRODUCT: TBD COLOR: PRIMARY WHITE BPG-1 SPANDREL GLAZING BACKPAINTED GLASS AT DIGITAL SCREEN WALLS MANUFACTURER: OPACI-COAT 300 PRODUCT: TBD COLOR: CUSTOM COLOR COATING BIRDIE BLUE #6-1595 (PANTONE 300 C) ACM-1 ALUMINUM COMPOSITE METAL PANEL EXTERIOR AND/OR INTERIOR MANUFACTURER: ALUCOBOND (OR APPROVED EQUAL) PRODUCT: TBD COLOR: MONTREAL BLUE 4128 PT-EXT-1 EXTERIOR PAINT MANUFACTURER: SHERWIN WILLIAMS PRODUCT: SUPERPAINT EXTERIOR ACRYLIC LATEX COLOR: CUSTOM COLOR FORMULA - PAINT TO MATCH BMO BLUE; PANTONE 300C, HEX #005EB8 FINISH: SATIN BASE: ULTRA DEEP EXTERIOR FINISHES F-2 FABRIC UPHOLSTERY MEETING NICHE BENCH SEAT MANUFACTURER: LDI INTERIORS SERIES: ENVIROLEATHER COLOR: MONTANA, GRIZZLY GRAY #752 F-1 FABRIC UPHOLSTERY MEETING NICHE BENCH BACK MANUFACTURER: DESIGNTEX SERIES: FELT 2MM COLOR: GRAPHITE AM001-803 NOTES: WRAP FABRIC OVER BOTH SIDES. STITCHING TO BE THICK LIGHT BLUE IN TOP, FRENCH... UPHOLSTERY SP-1 PAINTED METAL SOFFIT / SHADE POCKET SHADE POCKETS AND SOFFITS AT EXTERIOR STOREFRONT / CURTAIN WALL MANUFACTURER: ARMSTRONG OR APPROVED EQUAL PRODUCT: COMPASSO COLOR: FLAT WHITE #050 SIZE: WIDTHS AND LENGTHS PER PLAN, 9/16" THICKNESS NOTES: SEE CEILING DETAILS FOR ADDITIONAL INFORMATION. GC TO PROVIDE CLIPS, SUPPORT WIRES, AND OTHER HARDWARE FOR COMPLETE FINISHED INSTALLATION. ACT-3A DRIVE-UP CEILING EXTERIOR DRIVE-UP CEILING EXTERIOR MANUFACTURER: ARMSTRONG PRODUCT: METALWORKS VECTOR EXTERIOR PERFORATION: M2 - PERFORATED EDGE: SQUARE LAY-IN 15/16" COLOR: WHITE SIZE: 24" x 24" x 5/8" GRID: PRELUDE XL 15/16" GRID FINISH: WHITE NOTES: PROVIDE HOLD DOWN CLIPS FOR CEILING PANEL WIND RESISTANCE. ACT-3 ACOUSTIC CEILING TILE DRIVE-UP CEILING EXTERIOR MANUFACTURER: ARMSTRONG PRODUCT: METALWORKS VECTOR EXTERIOR PERFORATION: M1 - UNPERFORATED EDGE: SQUARE LAY-IN 15/16" COLOR: WHITE SIZE: 24" x 24" x 5/8" GRID: PRELUDE XL 15/16" GRID FINISH: WHITE NOTES: PROVIDE HOLD DOWN CLIPS FOR CEILING PANEL WIND RESISTANCE. ACT-2 ACOUSTIC CEILING TILE BACK OF HOUSE, RESTROOMS, STAFF ROOM MANUFACTURER: ARMSTRONG PRODUCT: CORTEGA #770 EDGE: SQUARE LAY-IN 15/16" COLOR: WHITE SIZE: 24" x 48" x 5/8" GRID: HEAVY DUTY PRELUDE XL 15/16" GRID FINISH: WHITE NOTES: CENTER IN ROOM UNLESS NOTED OTHERWISE ON RCP. ACT-1 ACOUSTIC CEILING TILE BANKING HALL, OFFICES, CLIENT-FACING SPACES MANUFACTURER: ARMSTRONG PRODUCT: ULTIMA HIGH NRC #1433 EDGE: BEVELED TEGULAR 15/16" COLOR: WHITE SIZE: 24" X 48" X 5/8" GRID: HEAVY DUTY PRELUDE XL 15/16 EXPOSED TEE GRID FINISH: WHITE NOTES: CENTER IN ROOM UNLESS NOTED OTHERWISE ON RCP. CEILING ES-1 QUARTZ COUNTERTOP STAFF ROOM COUNTERTOP MANUFACTURER: CAESARSTONE COLOR: 6141 OCEAN FOAM THICKNESS: 3/4" FINISH: POLISHED NOTES: PROVIDE GLACIER WHITE 3006 COLOR MATCHED ADHESIVE. SS-5 SOLID SURFACE WELLNESS ROOM COUNTERTOP MANUFACTURER: WILSONART COLOR: BASALT CONCRETE 9254SS FINISH: MATTE SS-4 SOLID SURFACE WINDOW SILLS MANUFACTURER: CORIAN COLOR: VERANO WHITE THICKNESS: 1/4" SS-3 SOLID SURFACE COUNTERS ON PL-6 CABINETS RESTROOM VANITY TOP MANUFACTURER: WILSONART COLOR: FROSTY WHITE MIRAGE 1573MG FINISH: MATTE SS-2 SOLID SURFACE TOP SURFACE OF STAND-ALONE MILLWORK MANUFACTURER: STARON COLOR: BRIGHT WHITE BW010 PL-21 PLASTIC LAMINATE WOOD SLATS MANUFACTURER: WILSONART COLOR: WALNUT HEIGHTS 7965K-12 FINISH: SOFT GRAIN PL-7 PLASTIC LAMINATE WOOD SLATS BACKER PANEL MANUFACTURER: WILSONART COLOR: BLACK #1595-60 FINISH: MATTE PL-6 PLASTIC LAMINATE STAFF ROOM FLOATING SHELF AND RESTROOM VANITY CABINET MANUFACTURER: WILSONART COLOR: RUSKIN OAK 17001K-57 FINISH: 57 ALIGNED OAK PL-5 PLASTIC LAMINATE STAFF ROOM BASE CABINETS MANUFACTURER: NEVAMAR DISTRIBUTOR: PANOLAM COLOR: WROUGHT IRON S6054 FINISH: GLOSS PL-4A PLASTIC LAMINATE COAT CLOSET AND JANITOR CLOSET SHELVING MANUFACTURER: NEVAMAR DISTRIBUTOR: PANOLAM COLOR: SMOKY WHITE S7027 FINISH: TEXTURED PL-4 PLASTIC LAMINATE MILLWORK CABINETS STAFF ROOM UPPER CABINETS MANUFACTURER: NEVAMAR DISTRIBUTOR: PANOLAM COLOR: SMOKY WHITE S7027-GL FINISH: GLOSS PL-3 PLASTIC LAMINATE COUPON BOOTH COUNTER, LOW WALLS MANUFACTURER: WILSONART COLOR: COLUMBIAN WALNUT 7943K-07 FINISH: TEXTURED GLOSS FINISH WITH AEON PL-2 PLASTIC LAMINATE ATM VESTIBULE WALL PANELS ATM VESTIBULE PORTAL MANUFACTURER: NEVAMAR DISTRIBUTOR: PANOLAM COLOR: PATRIOT BLUE S304 FINISH: COLOR-THROUGH LAMINATE NM55S3048; 1.3MM PL-1 PLASTIC LAMINATE MILLWORK COUNTERTOPS MILLWORK BASES MANUFACTURER: WILSONART COLOR: SLATE GREY D91-60 FINISH: HI-WEAR FINISH (CUSTOM BMO PRODUCT FOR BMO NATIONAL ACCOUNT) MEL-2 MELAMINE CABINET INTERIORS WHERE PL-3 IS USED, TOP REVEALS AT PL-3 CABINETS DRAWER INTERIOR AT PL-3 CABINETS MANUFACTURER: PANOLAM WANDEROSA COLOR: BLACK FINISH: SUPER MATTE (SM) MEL-1A MELAMINE CABINET INTERIORS WHERE PL-4 IS USED, TOP REVEALS AT PL-4 CABINETS, DRAWER INTERIORS AT PL-4 CABINETS, TOP AND SIDE PERIMETER FILLERS AT PL-3 CABINETS MANUFACTURER: PANOLAM WANDEROSA COLOR: INTERNATIONAL WHITE S557 FINISH: SUPER MATTE (SM) MEL-1 MELAMINE CABINET INTERIORS WHERE PL-4 IS USED, TOP REVEALS AT PL-4 CABINETS, DRAWER INTERIORS AT PL-4 CABINETS, TOP AND SIDE PERIMETER FILLERS AT PL-3 CABINETS MANUFACTURER: PANOLAM WANDEROSA COLOR: INTERNATIONAL WHITE S557 FINISH: SATIN ALTERNATE FINISH: GLOSS ML-1 MILLWORK BASE MEETING NICHE MANUFACTURER: CHEMETAL PRODUCT: 909 SATIN SILVER ALUMINUM; 2"H DM-1 MILLWORK BASE STAFF ROOM MANUFACTURER: WILSONART PRODUCT: ALUMASTEEL 6277 AWP-1 ACOUSTICAL WALL PANEL MEDIA SLAT WALL MANUFACTURER: SOUNDPLY PRODUCT: LATUS WALL PANEL WITH MICRO-PERFORATION FINISH: PAINTED MATTE BLACK PER MANUFACTURER STANDARD SIZE: 1" THICK NOTE: GC TO CUT PANELS IN FIELD TO SIZE AND MOUNT ON Z-CLIP BRACKETS AS DETAILED MILLWORK FINISHES TAG CATEGORY APPLICATION SPECIFICATION FINISH SCHEDULE ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 LEGEND -SCHEDULES NOT USED FURNITURE VENDOR CONTACTS POI: CONTACT: KELLY BODUCH PHONE: (416) 560-4001 EMAIL: BMO@POI.CA OFFICE REVOLUTION CONTACT: ERIC RIPES PHONE: (224) 430-9450 EMAIL: ERIPES@OFFICE-REVOLUTION.COM THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 FURNITURE SCHEDULE BMO BANK N.A. TENANT IMPROVEMENT YYYY.MM.DD 222702550 A-603 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 NOTES: 1. ALL FURNITURE ITEMS TO BE FURNISHED AND INSTALLED BY BMO VENDORS UNLESS NOTED OTHERWISE. 2. FURNITURE VENDOR TO VERIFY FINAL SPECS AND QUANTITIES. 3. FURNITURE SCHEDULE IS FOR REFERENCE ONLY. WB2 BACK PAINTED GLASS MARKERBOARD TEKNION 48"H x 96"W VERY WHITE OFFICE REVOLUTION MEETING ROOM MOUNTED AT 30" AFF TO BOTTOM OF BOARD. GC TO PROVIDE BLOCKING AS REQUIRED. WB1 BACK PAINTED GLASS MARKERBOARD TEKNION 36"H x 48"W VERY WHITE OFFICE REVOLUTION MEETING ROOM MOUNTED AT 36" AFF TO BOTTOM OF BOARD. GC TO PROVIDE BLOCKING AS REQUIRED. WB-P RECYCLING BIN AND HANGING WASTE BIN - - 102155 DESKSIDE RECYCLER, SINGLE BODY, MOBIUS LOOP; 7"H x 14.5"W x 11"D 101390 HANGING WASTE BASKET, SINGLE SOLID LIFT, 6.5"H x 7.5"W x 5.5"D BLACK BUSCH BLUE POI RRB AND AB DESKS WB WASTE BIN AND HANGING RECYCLING BIN RUBBERMAID 100335 BLACK WASTE BIN, BODY, 28Q; 15.25"H x 14.375"W x 10.5"D 102168 HANGING WASTE BASKET, SINGLE BODY; 6.5"H x... BLACK BUSCH BLUE POI OFFICES UL-4 UMAMI LOUNGE STEELCASE STRAIGHT LOUNGE - 3-SEATER (1) STLLNGEG LOUNGE-END CAP: SEA SALT COLOUR SCHEME AND SEA SALT COLOUR SCHEME CONTRASTING FASCIA (1) STLLNGST1 LOUNGE-STRAIGHT: LAGOON AND LAGOON CONTRASTING FASCIA (1) STLLNGCR1 LOUNGE-CORNER: ROYAL BLUE COLOUR SCHEME AND ROYAL BLUE COLOUR SCHEME CONTRASTING FASCIA POI LOUNGE TT1A COUPON BOOTH TABLE TEKNION EXPANSION CASEGOODS WITH HALF MODESTY PANEL, 1" WORK SURFACE, 24"D x 18, 24, 30, 36, 42, 48, 54, 60, 66, 72, 78, 84" (SELECT ONE) JAVA WALNUT WITH BLACK GROMMETS OFFICE REVOLUTION COUPON BOOTH TS2 TASK STOOL TEKNION ABILITY SPINNER STOOL WITH ROUND SEAT BLACK WITH MESH BACK SEAT FABRIC: MOMENTUM, FUNDAMENTALS, BLACK 4001-19; EBONY SATIN BASE OFFICE REVOLUTION ATM ROOM TS1 TASK STOOL TEKNION T-3 TASK STOOL BLACK WITH MESH BACK SEAT FABRIC: MOMENTUM, FUNDAMENTALS, BLACK 4001-19 PNEUMATIC LIFT HEIGHT ADJUSTABILITY; HARD CASTERS OFFICE REVOLUTION DRIVE-UP TELLER TCRS-S TCR UNIT SHROUD, SINGLE - -JAVA WALNUT LAMINATE TOP; STORM WHITE LAMINATE FINISH; PLEXIGLASS; DISTRICT HANDLES; BLACK VINYL DRAWER BOXES OFFICE REVOLUTION SINGLE-SIDED RRB DESK WITH TCR INDIVIDUAL KEY TCRS-D TCR UNIT SHROUD, DOUBLE TEKNION -JAVA WALNUT LAMINATE TOP; STORM WHITE LAMINATE FINISH; PLEXIGLASS; DISTRICT HANDLES; BLACK VINYL DRAWER BOXES OFFICE REVOLUTION DOUBLE-SIDED RRB DESK WITH TCR INDIVIDUAL KEY TC3 TASK CHAIR GLOBAL FURNITURE GROUP SUPRA #5331-4 MEDIUM - BACK TILTER MID-BACK FABRIC: TERRACE ECHO TC74 OFFICE REVOLUTION COUPON BOOTH TC2 TASK CHAIR GLOBAL FURNITURE GROUP GLOBAL ACCORD MESH MID-BACK CHAIR BLACK FABRIC UPHOLSTERY OFFICE REVOLUTION MEETING ROOM TC1 TASK CHAIR TEKNION CONTESSA FRAME: BLACK BASE: PAINTED ALUMINUM CASTERS FOR CARPET FLOORING OFFICE REVOLUTION OFFICES, WORKSTATIONS ST-6 STAFF TABLE STEELCASE 30" X 30" OR 30" X 42" UNIVERSAL SERIES WITH X BASE WHITE WITH BLACK BASE POI STAFF ROOM REFER TO PLAN FOR SIZE. ST-5 STAFF TABLE GLOBAL FURNITURE GROUP GLOBAL LICENSE TABLE 36" x 36" HIGH PRESSURE LAMINATE FINISH; DESIGNER WHITE TOP WITH BLACK FLAT SQUARE COLUMN BASE OFFICE REVOLUTION STAFF ROOM ST-4 STAFF TABLE GLOBAL FURNITURE GROUP GLOBAL LICENSE TABLE 42" x 42" HIGH PRESSURE LAMINATE FINISH; DESIGNER WHITE TOP WITH BLACK FLAT SQUARE COLUMN BASE OFFICE REVOLUTION STAFF ROOM ST-3 STAFF TABLE GLOBAL FURNITURE GROUP GLOBAL LICENSE TABLE 30" x 60" HIGH PRESSURE LAMINATE FINISH; DESIGNER WHITE TOP WITH BLACK FLAT SQUARE COLUMN BASE OFFICE REVOLUTION STAFF ROOM ST-2 STAFF TABLE GLOBAL FURNITURE GROUP GLOBAL LICENSE TABLE 36" x 72" HIGH PRESSURE LAMINATE FINISH; DESIGNER WHITE TOP WITH BLACK FLAT SQUARE COLUMN BASE OFFICE REVOLUTION STAFF ROOM ST-1 STAFF TABLE GLOBAL FURNITURE GROUP GLOBAL LICENSE TABLE 42" x 84" HIGH PRESSURE LAMINATE FINISH; DESIGNER WHITE TOP WITH ADA COMPLIANT BASE OFFICE REVOLUTION STAFF ROOM S04 BANQUETTE TEKNION BANQS WITH LOW SCREEN FINISH: LUUM GRID STATE HYDROPOWER 4090-A SEAT AND SCREEN: LUUM FINEGRAIN VOLCANIC ASH LEGS: EBONY OFFICE REVOLUTION STAFF ROOM SO3 BANQUETTE STEELCASE COALESSE CIRCA LEGS: NATURAL OAK BACK UPHOLSTERY: DESIGNTEX, ROCKET NAVY, 2693-404 SEAT UPHOLSTERY: DESIGNTEX, SORANO KEYSTONE, 3403-802 POI STAFF ROOM SO2 2-SEATER SOFA GLOBAL 54.5"W x 29 1/2" x 28 1/2"H GLOBAL WIND SOFA 3-SEATER FABRIC: ETCH ET91 MAGNET POI STAFF ROOM SO1 3-SEATER SOFA GLOBAL 79"W x 29 1/2" x 28 1/2"H GLOBAL WIND SOFA 3-SEATER FABRIC: ETCH ET91 MAGNET POI STAFF ROOM SKI STANDING KIOSK TEKNION 36"H x 43.5" x 29.75" OVAL SHAPE TOP: WILSONART FROSTY WHITE SOLID SURFACE BASE: OCTOLAM #728 OCTOPUS INTERIOR: STORM WHITE PULLS: DONG MOCKETT SATIN NICKEL OFFICE REVOLUTION BANKING HALL KIOSK IS FOR EMPLOYEE USE SC3 STAFF CHAIR, STACKING TEKNION NORTH 56 ARNE CHAIR: SISAL UPHOLSTERED SEAT: LUUM, FUNDAMENTALS, BANNER 4001-01 OFFICE REVOLUTION STAFF ROOM SC2 STAFF CHAIR, NON-STACKING TEKNION NORTH 56 SICLA FINISH: POLYURETHANE SHELL LEGS: SISAL UPHOLSTERED SEAT: LUUM, FUNDAMENTALS, BANNER 4001-01 OFFICE REVOLUTION STAFF ROOM SC1 STAFF CHAIR, STACKING TEKNION NAMI CHAIR: FEARLESS RED FRAME: CHROME; NO ARMS OFFICE REVOLUTION STAFF ROOM RWS-SA ADJUSTABLE HEIGHT WORKSTATION, SINGLE-SIDED, WITHOUT GLASS DIVIDER TEKNION -- FINISH: JAVA WALNUT CREDENZA WITH METAL ANTHRACITE DUAL HEIGHT STORAGE; DISTRICT FOUNDATION EBONY PULLS OFFICE REVOLUTION RETAIL WORKSTATION FURNITURE VENDOR TO VERIFY LEFT OR RIGHT CONFIGURATION RWS-S ADJUSTABLE HEIGHT WORKSTATION, SINGLE-SIDED, WITH GLASS DIVIDER TEKNION - - FINISH: JAVA WALNUT CREDENZA WITH METAL ANTHRACITE DUAL HEIGHT STORAGE; DISTRICT FOUNDATION EBONY PULLS, STORM WHITE LAMINATE OFFICE REVOLUTION RETAIL WORKSTATION FURNITURE VENDOR TO VERIFY LEFT OR RIGHT CONFIGURATION RWS-D2 ADJUSTABLE HEIGHT WORKSTATION, DOUBLE-SIDED TEKNION - - FINISH: JAVA WALNUT CREDENZA WITH METAL ANTHRACITE DUAL HEIGHT STORAGE; DISTRICT FOUNDATION EBONY PULLS, STORM WHITE LAMINATE OFFICE REVOLUTION RETAIL WORKSTATION RB RECYCLING BIN - -100331 RECYCLING BASKET, BODY 28Q, MOBIUS LOOP; 15.25"H x 14.375"W x 10.5"D ROYAL BLUE POI ENCLAVE, WORK ROOM OFR-SS1 ADJUSTABLE HEIGHT DESK WITH RETURN, LOWER CREDENZA, AND STORAGE STACKER TEKNION DESK: 4'-10"W x 6'-4"D STORAGE: (1) 7'-6"W x 1'-8"D LOWER CREDENZA; (1) 3'-0"W x 1'-5"D STORAGE STACKER DESK: JAVA WALNUT LAMINATE; EBONY HANDLES STORAGE: STORM WHITE LAMINATE CASE; JAVA LAMINATE FRONT; EBONY DISTRICT HANDLES; INTERIOR DRAWERS IN BLACK OFFICE REVOLUTION OFFICES OFR-LS1 ADJUSTABLE HEIGHT DESK WITH RETURN, LATERAL FILES, AND PEDESTAL BOX STORAGE TEKNION DESK: 4'-10"W x 5'-3"D STORAGE: (1) 24"D x 18"H x 32"W SINGLE-DRAWER LATERAL FILE ; (1) 24"D x 36"H x 32"W 3H LATERAL FILE; (1) 18"D x 29"H x 16"W PEDESTAL BOX. DESK: JAVA WALNUT LAMINATE; EBONY HANDLES STORAGE: STORM WHITE LAMINATE CASE; JAVA LAMINATE FRONT; EBONY DISTRICT HANDLES; INTERIOR DRAWERS IN BLACK OFFICE REVOLUTION OFFICES MT10P MEETING TABLE - 10 PERSON TEKNION 42" x 120" RECTANGULAR CONFERENCE TABLE WILSONART COLUMBIAN WALNUT 7943K-07 TOP AND BASE PANELS; BLACK TRIM ON BASES OFFICE REVOLUTION MEETING ROOM WITH POWER. PROVIDE ONE 7.1" X 5.75" CUT OUT IN TABLE TO ACCEPT EXTRON 700 CUBBY WITH ONE REMOVABLE COVERO F PANEL BASE REDUCED FOR 7" CLEAR UNDER TABLE. MOUSE HOLE 4" X 1.25" AT THE BOTTOM FOR POWER FEED. MT8P MEETING TABLE - 8 PERSON TEKNION 42" x 96" RECTANGULAR CONFERENCE TABLE WILSONART COLUMBIAN WALNUT 7943K-07 TOP AND BASE PANELS; BLACK TRIM ON BASES OFFICE REVOLUTION MEETING ROOM WITH POWER. PROVIDE ONE 7.1" X 5.75" CUT OUT IN TABLE TO ACCEPT EXTRON 700 CUBBY WITH ONE REMOVABLE COVERO F PANEL BASE REDUCED FOR 7" CLEAR UNDER TABLE. MOUSE HOLE 4" X 1.25" AT THE BOTTOM FOR POWER FEED. MT6P MEETING TABLE - 6 PERSON TEKNION 42" x 72" RECTANGULAR CONFERENCE TABLE WILSONART COLUMBIAN WALNUT 7943K-07 TOP AND BASE PANELS; BLACK TRIM ON BASES OFFICE REVOLUTION MEETING ROOM WITH POWER. PROVIDE ONE 7.1" X 5.75" CUT OUT IN TABLE TO ACCEPT EXTRON 700 CUBBY WITH ONE REMOVABLE COVERO F PANEL BASE REDUCED FOR 7" CLEAR UNDER TABLE. MOUSE HOLE 4" X 1.25" AT THE BOTTOM FOR POWER FEED. MT4P-R MEETING TABLE - 4 PERSON TEKNION 42" DIA. ROUND CONFERENCE TABLE WILSONART COLUMBIAN WALNUT 7943K-07 TOP AND BASE EBONY OFFICE REVOLUTION MEETING ROOM WITH POWER. PROVIDE ONE 7.1" X 5.75" CUT OUT IN TABLE TO ACCEPT EXTRON 700 CUBBY REMOVEABLE ACCESS PANEL IN TAPERED ROUND BASE. MC1 SLEEPER CHAIR GLOBAL PRIMACARE GC3610 32" SINGLE SLEEPER CHAIR ARM CAPS: HARVEST OAK WOOD FABRIC: MORBERN ARC SILVERSCREEN AC-507 OFFICE REVOLUTION MA3 MONITOR ARM HUMANSCALE X22BTBBTB-M2.1 BLACK FINISH WITH BLACK TRIM OFFICE REVOLUTION OFFICE DESKS MA2 MONITOR ARM HUMANSCALE M21BTBBTB-M2.1 BLACK FINISH WITH BLACK TRIM OFFICE REVOLUTION ATM ROOM, BANKER DESKS LC5 LOUNGE CHAIR KEILHAUER PONDER 68704 4-LEG LOW BACK LOUNGE CHAIR WITH GLIDE, AUTORETURN, AND ARMS FABRIC: MERKAT M1805 CHERRY BASE: POLISHED ALUMINUM POI LOUNGE LC3 LOUNGE CHAIR KEILHAUER CAHOOTS RELAX CHAIR 9020 ON SLED BASE PROMESSA 363-1387 DOGWOOD UPHOLSTERY POI LOUNGE LT2 LOUNGE SIDE TABLE KEILHAUER CAHOOTS SIDE TABLE 17.25"DIA. x 17.25"H CHROME BASE TOP AND BACK PAINTED SILVER TOP POI LOUNGE LT1 LOUNGE LOW TABLE KEILHAUER CAHOOTS LARGE ROUND LOW TABLE 37"DIA. x 13.25"H CHROME BASE TOP AND BACK PAINTED SILVER TOP POI LOUNGE LOC STAFF LOCKERS, 2-TIER WOLTER GROUP PREVIX WELDED LOCKERS F-70 SERIES, 12"W x 18"D x 76"H (INCLUDING 4" BASE)WHITE 9301 OFFICE REVOLUTION STAFF ROOM OR CORRIDOR PROVIDE 1954-ADA COMBINAISO LOCK ON BOTTOM DOORS. GC1 GUEST CHAIR TEKNION SYNAPSE WOOD GUEST CHAIR (NYSN) FINISH: LUUM FINE GRAIN VOLCANIC ASH 4046-08 WOOD: MATCH WILSONART COLUMBIAN WALNUT OFFICE REVOLUTION QUEUING AREA FR6 6-HIGH LATERAL FILE CABINET TEKNION LEDGER LATERAL FILE LLF60 / 61 EBONY SATIN METAL FINISH WHEN IN BOH; STORM WHITE METAL FINISH WHEN CLIENT FACING; JAVA LAMINATE TOP WHEN CLIENT FACING, LAMINATE TO MATCH FURNITURE WHEN IN PRIVATE OFFICES.OFFICE REVOLUTION FILING (30", 36", 42")W x (18", 20")D x 75.2"H , PROVIDE WITH FULL PULL (UPDATE WIDTH AND DEPTH PER PROJECT) FR5 5-HIGH LATERAL FILE CABINET TEKNION LEDGER LATERAL FILE LLF50 / 51 EBONY SATIN METAL FINISH WHEN IN BOH; STORM WHITE METAL FINISH WHEN CLIENT FACING; JAVA LAMINATE TOP WHEN CLIENT FACING, LAMINATE TO MATCH FURNITURE WHEN IN PRIVATE OFFICES.OFFICE REVOLUTION FILING (30", 36", 42")W x (18", 20")D x 65.6"H (COMBO HEIGHT), PROVIDE WITH FULL PULL (UPDATE WIDTH AND DEPTH PER PROJECT) FR4 4-HIGH LATERAL FILE CABINET TEKNION LEDGER LATERAL FILE LLF40 EBONY SATIN METAL FINISH WHEN IN BOH; STORM WHITE METAL FINISH WHEN CLIENT FACING; JAVA LAMINATE TOP WHEN CLIENT FACING, LAMINATE TO MATCH FURNITURE WHEN IN PRIVATE OFFICES.OFFICE REVOLUTION FILING (42")W x (20")D x 51.2"H (COMBO HEIGHT), PROVIDE WITH FULL PULL FR3 3-HIGH LATERAL FILE CABINET TEKNION LEDGER LATERAL FILE LLF30 EBONY SATIN METAL FINISH WHEN IN BOH; STORM WHITE METAL FINISH WHEN CLIENT FACING; JAVA LAMINATE TOP WHEN CLIENT FACING, LAMINATE TO MATCH FURNITURE WHEN IN PRIVATE OFFICES.OFFICE REVOLUTION FILING (30", 36", 42")W x (18", 20")D x 40"H (COMBO HEIGHT), PROVIDE WITH FULL PULL (UPDATE WIDTH AND DEPTH PER PROJECT) FR2 2-HIGH LATERAL FILE CABINET TEKNION LEDGER LATERAL FILE LLF20 EBONY SATIN METAL FINISH WHEN IN BOH; STORM WHITE METAL FINISH WHEN CLIENT FACING; JAVA LAMINATE TOP WHEN CLIENT FACING, LAMINATE TO MATCH FURNITURE WHEN IN PRIVATE OFFICES.OFFICE REVOLUTION FILING (30", 36", 42")W x (18", 20")D x 27.2"H (COMBO HEIGHT), PROVIDE WITH FULL PULL. (UPDATE WIDTH AND DEPTH PER PROJECT) FF PEDESTAL WITH FILE, FILE TEKNION LEDGER PEDESTAL LPFN EBONY SATIN METAL FINISH WHEN IN BOH; STORM WHITE METAL FINISH WHEN CLIENT FACING; JAVA LAMINATE TOP WHEN CLIENT FACING, LAMINATE TO MATCH FURNITURE WHEN IN PRIVATE OFFICES.OFFICE REVOLUTION EMPLOYEE WORK AREAS 15"W X 22"D X 27.2" H, PROVIDE WITH FULL PULL FAA -TEKNION --OFFICE REVOLUTION - CR2 CREDENZA TEKNIONL FOUNDATIONS CREDENZA, 50"W x 20"D x 20"H WILSONART COLUMBIAN WALNUT 7943K-07 WITH SILVER GLIMMER TRIM OFFICE REVOLUTION MEETING ROOM PROVIDE 12" x 12" ACCESS CUTOUT SQUARE AT BACK OF CREDENZA FOR A/V EQUIPMENT; DVD DRAWER. CR1 CREDENZA TEKNION FOUNDATIONS CREDENZA, 74"W x 20"D x 28"H WILSONART COLUMBIAN WALNUT 7943K-07 WITH SILVER GLIMMER TRIM OFFICE REVOLUTION MEETING ROOM PROVIDE 12" x 12" ACCESS CUTOUT SQUARE AT BACK OF CREDENZA FOR A/V EQUIPMENT; DVD DRAWER. CMR-L1 ADJUSTABLE HEIGHT CUSTOMER MEETING ROOM DESK TEKNION - -JAVA WALNUT AND STORM WHITE LAMINATE. EBONY PAINT.OFFICE REVOLUTION CUSTOMER MEETING ROOM CC5 CLIENT CHAIR TEKNION STUDIO TK KUSKOA FABRIC: LUUM PERCEPT CARDINALITY 4040-17 LEGS: EBONY OFFICE REVOLUTION CUSTOMER MEETING ROOM CC3 CLIENT CHAIR STEELCASE STERLING CONFERENCE CHAIR WITH ARMS FABRIC: STEELCASE; BUZZ2; GREY F516 5 STAR BASE: BLACK 0835 POI OFFICES CC2B CLIENT CHAIR TEKNION ZONES CLUB CHAIR FABRIC: LUUM PERCEPT; 4040-17 CARDINALITY 5 STAR BASE: EBONY OFFICE REVOLUTION AB DESKS CC2A CLIENT CHAIR TEKNION ZONES CLUB CHAIR FABRIC: LUUM HEATHER TECH; 4059-21 OCEAN TECH 5 STAR BASE: EBONY OFFICE REVOLUTION RRB DESKS CC1A CLIENT CHAIR - 4 BASE WITH NO ARMS KEILHAUR FLIT 3810 NO ARMS SEAT: COLLECTION: SUSTAIN; GRIZZLY GRAY 752 POI CC1 CLIENT CHAIR - 4 BASE WITH ARMS KEILHAUR FLIT 3813 CUSTOM ARM CAPS: W20 STAIN TO MATCH WILSONART COLOMBIAN WALNUT 7943K-07 SEAT: COLLECTION SUSTAIN, GRIZZLY GRAY 752 POI BANKING HALL CB3 THREE SEATER LOUNGE BENCH WITH BACK TEKNION STUDIO TK CLIQUE STP3B; 6'-1"W x 2'-0"D x 2'-7"H BACK FABRIC: LUUM DIGI TWEED BASALT 4048-08 SEAT FABRIC: LUUM INTERSTICE VESTIGE 4061-10 LEGS: EBONY METAL OFFICE REVOLUTION RETAIL OFFICES CB2 TWO SEATER LOUNGE BENCH WITH BACK TEKNION STUDIO TK CLIQUE STP2B; 0"W x 2'-0"D x 2'-7"H BACK FABRIC: LUUM DIGI TWEED BASALT 4048-08 SEAT FABRIC: LUUM INTERSTICE VESTIGE 4061-10 LEGS: EBONY METAL OFFICE REVOLUTION CUSTOMER MEETING ROOM, OFFICES BS2 BAR STOOL KEILHAUER FLIT 3811 STOOL SEAT BASE FABRIC: RED VINYL BACK FABRIC: GREY MESH MESH BACK: SPECIAL FT11 MATTERHORN FRAME: CHROME GLIDES: SPECIAL ALLIANCE PLASTIC POI STANDING KIOSK BBF PEDESTAL WITH BOX, BOX, FILE TEKNION LEDGER PEDESTAL LPFN EBONY SATIN METAL FINISH WHEN IN BOH; STORM WHITE METAL FINISH WHEN CLIENT FACING; JAVA LAMINATE TOP WHEN CLIENT FACING, LAMINATE TO MATCH FURNITURE WHEN IN PRIVATE OFFICES.OFFICE REVOLUTION EMPLOYEE WORK AREAS 15"W x 22"D x 27.2" H, PROVIDE WITH FULL PULL AVC MOBILE A/V CART WITH CASTERS TEKNION AUDIENCE A/V CART WITH SOLID DOORS, 32"W x 36"H JAVA WALNUT LAMINATE; EBONY HANDLES OFFICE REVOLUTION MEETING ROOM WITH LOCK TAG DESCRIPTION MANUFACTURER MODEL FINISH SUPPLIER APPLICATION NOTES FURNITURE SCHEDULE ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #3 SS DR 2024/11/12 1 1 EALLL 10/28/2024 LEGEND -SCHEDULES NOT USED THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 LIGHT FIXTURE SCHEDULE BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 06/10/24 222702550 A-604 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 NOTE: 1. ALL LIGHT FIXTURES TO BE SOURCED THROUGH ACUITY BRANDS UNLESS NOTED OTHERWISE, SEE VENDOR CONTACT INFORMATION ON COVER SHEET. 2. GC SHALL PROVIDE CUT SHEETS OF ALL LIGHT FIXTURES FOR REVIEW AND APPROVAL BY ARCHITECT. SUBMITTALS SHALL INCLUDE LAMP INFORMATION SHEETS ALONG WITH FIXTURE INFORMATION SHEETS. 3. GC SHALL VERIFY CEILING COMPATIBILITY, MOUNTING CONDITIONS, CLEARANCES AND STRUCTURAL SUSPENSION SYSTEM PRIOR TO FIXTURE PROCUREMENT. 4. GC SHALL PROVIDE ALL PARTS AND HARDWARE AS NECESSARY FOR COMPLETE INSTALLATION. 5. FOR SITE LIGHTING RELATED, REFER TO ELECTRICAL "ES" SHEETS. LW3 DECORATIVE WALL SCONCE ARTIKA TIVOLI 14VAN-TI-MBJ 16 WATTS 3500K LED 1500 LUMENS DIMMING DRIVER BLACK COUPON BOOTH ACUITY BRANDS WALL MOUNTED 24" ABOVE COUNTER SURFACE. CENTER OVER COUNTER. REFER TO INTERIOR ELEVATIONS LW2 24" DECORATIVE WALL SCONCE EUREKA LIGHTING EXPO 3545-24-LED-30-90-120V-DV-BLKE-WH XX WATTS 3000K LED 0-10V DIMMING DRIVER BLACK FINE TEXTURE WHITE DIFFUSER WELLNESS ROOM ACUITY BRANDS WALL MOUNTED AT XX" A.F.F. CENTER OVER MIRROR. REFER TO INTERIOR ELEVATIONS LW1 DECORATIVE WALL SCONCE CERNO GROUP TERSUS 03-136-D-C-35-P1 13 WATTS 3500K LED 1130 NOMINAL LUMENS 0-10V DIMMING DRIVER CARRARA MARBLE FACE DARK STAINED WALNUT EDGE OFFICES ACUITY BRANDS WALL MOUNT AT 72" A.F.F. SPACING TO BE 30" ON CENTER. PROVIDE 2 SCONCES PER OFFICE LS2D 96" PENDANT MOUNTED INDUSTRIAL LINEAR LIGHTING LITHONIA LIGHTING CLX CLX L96 SEF RDL MVOLT GZ10 35K 80CRI WH XX WATTS 3500K LED 0-10V DIMMING DRIVER WHITE ATM / LAN ROOM JANITOR'S CLOSET VAULT STORAGE ACUITY BRANDS CEILING MOUNTED TO ACT. LS2C 48" PENDANT MOUNTED INDUSTRIAL LINEAR LIGHTING LITHONIA LIGHTING CLX CLX L48 SEF RDL MVOLT GZ10 35K 80CRI WH 25.5 WATTS 3500K LED 4000 LUMENS 0-10V DIMMING DRIVER WHITE ATM / LAN ROOM JANITOR'S CLOSET VAULT STORAGE ACUITY BRANDS CEILING MOUNTED TO ACT. LS2B 36" PENDANT MOUNTED INDUSTRIAL LINEAR LIGHTING LITHONIA LIGHTING CLX CLX L36 SEF RDL MVOLT GZ10 35K 80CRI WH XX WATTS 3500K LED 0-10V DIMMING DRIVER WHITE ATM / LAN ROOM JANITOR'S CLOSET VAULT STORAGE ACUITY BRANDS CEILING MOUNTED TO ACT. LS2A 24" PENDANT MOUNTED INDUSTRIAL LINEAR LIGHTING LITHONIA LIGHTING CLX CLX L24 SEF RDL MVOLT GZ10 35K 80CRI WH XX WATTS 3500K LED 0-10V DIMMING DRIVER WHITE ATM / LAN ROOM JANITOR'S CLOSET VAULT STORAGE ACUITY BRANDS CEILING MOUNTED TO ACT. LS1C 96" SURFACE MOUNTED INDUSTRIAL LINEAR LIGHT LITHONIA LIGHTING ZL1D ZL1D L96 5000LM FST MVOLT 35K 80CRI WH 41 WATTS 3500K LED 5000 LUMENS 0-10V DIMMING DRIVER WHITE NIGHT DEPOSIT NICH COAT CLOSET ACUITY BRANDS CEILING MOUNTED TO GYP. BOARD. LS1B 48' SURFACE MOUNTED INDUSTRIAL LINEAR LIGHT LITHONIA LIGHTING ZL1D ZL1D L48 5000LM FST MVOLT 35K 80CRI WH 41 WATTS 3500K LED 5000 LUMENS 0-10V DIMMING DRIVER WHITE NIGHT DEPOSIT NICHE COAT CLOSET ACUITY BRANDS CEILING MOUNTED TO GYP. BOARD. LS1A 24" SURFACE MOUNTED INDUSTRIAL LINEAR LIGHT LITHONIA LIGHTING ZL1D ZL1D L24 5000LM FST MVOLT 35K 80CRI WH 41 WATTS 3500K LED 5000 LUMENS 0-10V DIMMING DRIVER WHITE NIGHT DEPOSIT NICHE COAT CLOSET ACUITY BRANDS CEILING MOUNTED TO GYP. BOARD. LP12 DESK LAMP NORTHERN LIGHT TECHNOLOGIES BOXELITE DESK LAMP WELLNESS ROOM NONE FREESTANDING DESK LAMP. LP11C ACCENT CLUSTER PENDANT LIGHT SCHNEID STUDIO JUNIT "DROP"6 WATTS 2700K LED DIMMABLE MAGENTA / PINK / NATURAL WOOD STAFF ROOM ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. TO BE CENTERED OVER STAFF ROOM TABLE. MOUNT AT 7'-0" A.F.F. LP11B ACCENT CLUSTER PENDANT LIGHT SCHNEID STUDIO JUNIT "COLUMN"6 WATTS 2700K LED DIMMABLE WHITE / NATURAL WOOD / BLUE STAFF ROOM ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. TO BE CENTERED OVER STAFF ROOM TABLE. MOUNT AT 6'-6" A.F.F. LP11A ACCENT CLUSTER PENDANT LIGHT SCHNEID STUDIO JUNIT LAMP "RECORD"6 WATTS 2700K LED DIMMABLE WHITE / NATURAL WOOD / CORAL STAFF ROOM ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. TO BE CENTERED OVER STAFF ROOM TABLE. MOUNT AT 6'-0" A.F.F. LP10 ACCENT PENDANT LIGHT SCHNEID STUDIO EIKON CIRCUS XX WATTS 3000K LED DIMMABLE SKY BLUE OAK WOOD FINISH STAFF ROOM ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. TO BE CENTERED OVER STAFF ROOM TABLE. MOUNT AT 72" A.F.F. LP9B ACCENT PENDANT LIGHT SCHNEID STUDIO EIKON BASIC 10 WATTS 3000K LED 3000 LUMENS DIMMABLE TRUE BLUE OAK WOOD FINISH STAFF ROOM ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. TO BE CENTERED OVER STAFF ROOM TABLE. MOUNT AT 72" A.F.F. LP9A ACCENT PENDANT LIGHT SCHNEID STUDIO EIKON BASIC 10 WATTS 3000K LED 3000 LUMENS DIMMABLE POPPY RED OAK WOOD FINISH STAFF ROOM ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. TO BE CENTERED OVER STAFF ROOM TABLE. MOUNT AT 72" A.F.F. LP8C ACCENT CLUSTER PENDANT LIGHT SCHNEID STUDIO STUCCO LAMP NO. 3 XX WATTS 3000K LED DIMMABLE CLAY OR/AND LAPIS BLUE BANKING HALL LOUNGE ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. MOUNT AT X'-X" A.F.F. LP8B ACCENT CLUSTER PENDANT LIGHT SCHNEID STUDIO STUCCO LAMP NO. 2 XX WATTS 3000K LED DIMMABLE CLAY OR/AND LAPIS BLUE BANKING HALL LOUNGE ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. MOUNT AT X'-X" A.F.F. LP8A ACCENT CLUSTER PENDANT LIGHT SCHNEID STUDIO STUCCO LAMP NO. 1 XX WATTS 3000K LED DIMMABLE CLAY OR/AND LAPIS BLUE BANKING HALL LOUNGE ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. MOUNT AT X'-X" A.F.F. LP7 ACCENT PENDANT LIGHT HEMERA LIGHTING NEPTUNE 5 NFC-02-CFG-COB-12W/90/30K-D010-UNV XX WATTS 3000K LED 1535 LUMENS 0-10V DIMMING DRIVER TO 1% BLACK PAINTED FINISH CLEAR FROSTED GLASS BANKING HALL LOUNGE ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. MOUNT AT X'-X" A.F.F. (DESIGNER NOTE: TO BE USED IN BRANCHES WITH LOW CEILINGS) LP6 ACCENT PENDANT LIGHT SEED DESIGN SIRCLE PENDANT S SG-100PV XX WATTS 3000K LED N/A MATTE BLACK BANKING HALL LOUNGE ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. MOUNT AT X'-X" A.F.F. LP5 ACCENT ACOUSTIC PENDANT LIGHT EUREKA LIGHTING CYCLE ACOUSTIC SERIES 4801-(SIZE)-XXX XX WATTS 3000K DIRECT / INDIRECT LED 0-10V DIMMING DRIVER WHITE FINE TEXTURE CANOPY BLACK FINE TEXTURE RING (FELT FINISH) BANKING HALL LOUNGE ACUITY BRANDS CEILING PENDANT MOUNT AT ACT . MOUNT AT X'-X" A.F.F. (DESIGNER NOTE: SIZE WILL VARY DEPENDING SCALE OF LOUNGE AREA AND WILL NEED TO BE UPDATED PER PROJECT. CONFIRM WITH BMO. AVAILABLE SIZES: 24", 36", 54", 72". FELT FINISH TO BE DETERMINED BY BMO DESIGN MANAGER AND UPDATED PER PROJECT. SEE SPEC SHEET FOR AVAILABLE FINISHES) LP4 ACCENT ACOUSTIC PENDANT LIGHT EUREKA LIGHTING ATOLL SERIES 4850DI-48"-LED-30-90-120-DV 29 WATTS 3000K DIRECT / INDIRECT LED 829 LUMENS 0-10V DIMMING DRIVER WHITE FINE TEXTURE CANOPY WHITE POWER CORD BLACK FINE TEXTURE RING BANKING HALL LOUNGE ACUITY BRANDS CEILING PENDANT MOUNT AT ACT . MOUNT AT 8'-0" A.F.F. LP3 ACCENT ACOUSTIC PENDANT LIGHT EUREKA LIGHTING FRANK 4276D-25-LED.REG-30-90-120V-DV-AC-60-RC1-(CABLE FINISH)-(SHADE FINISH)-WH XX WATTS 3000K LED 0-10V DIMMING DRIVER WHITE FINE TEXTURE CANOPY (POWER CABLE FINISH) (SHADE FINISH) STAFF ROOM BANKING HALL LOUNGE ACUITY BRANDS CEILING PENDANT MOUNT AT ACT . MOUNT AT X'-X" A.F.F. (DESIGNER NOTE: CABLE AND SHADE FINISH TO BE DETERMINTED BY BMO DESIGNER MANAGER AND UPDATED PER PROEJCT. SEE SPEC SHEET FOR AVAILABLE FINISHES) LP2 48" LINEAR PENDANT LIGHT BLACKJACK LIGHTING FLAIR FLR-48L-BL-27U-30K-WN-096 41 WATTS 3000K LED 2080 DELIEVERED LUMENS 0-10V DIMMING DRIVER MATTE BLACK WALNUT END CAP OFFICES MEETING ROOM ACUITY BRANDS CEILING PENDANT MOUNT AT ACT. CENTER OVER DESK. MOUNT AT 6'-2" A.F.F. LP1 PENDANT LIGHTING MARK ARCHITECTURAL SLOT 4 SERIES S4PD LOP (TOTAL RUN LENGTH) 90CRI 35K SCT MIN1 FLL MVOLT WHTT ZT F1/xxA RDCY WHTCY WCRD XX WATTS 3500K LED 0-10V DIMMING DRIVER TO 1%BLACK WOOD SLAT CEILING AT MEDIA WALL ACUITY BRANDS CEILING PENDANT MOUNT AT WOOD SLAT CEILING . MOUNT AT X'-X" A.F.F. (DESIGNER NOTE: THIS LIGHT FIXTURE IS ONLY TO BE USED WHERE THERE IS A SUSPENDED WOOD SLAT CEILING FEATURE) (DESIGNER NOTE: AVAILABLE IN 2', 3', 4', 5', 6', 7', 8' LENGTHS) LL1 RECESSED LINEAR WALL WASHER MARK ARCHITECTURAL SLOT 2 LED SL2L-LOP-4'-FLP-TG-90CRI-30K-400LMF-120-XXX/AMF 16 WATTS 3000K LED 1232 LUMENS 0-10V DIMMING DRIVER TO 1%WHITE (SATIN)MURAL WALL(S) ART WALL(S)ACUITY BRANDS CEILING RECESSED IN ACT. CENTER OVER ART WORK LOCATION. LD1 4" SQUARE RECESSED DOWNLIGHT GOTHAM IVO SERIES IVO4SQS-D-15LM-35K-80CRI-WD-MIN10-MVOLT-ZT-NCH- P-WMR-F 15.7 WATTS 3500K LED 1500 LUMENS CONSTANT CURRENT, DIMMING TO 1%WHITE OFFICES ATM VESTIBULE STAFF ROOM SOFFIT ACUITY BRANDS LC3B 48" LINEAR COVE LIGHT MARK ARCHITECTURAL MARKLINE MKS101-LLP-4FT-MSL4-M100FMC-90CRI-35K-250LMF- 10X60DEG-MIN1-MVOLT-WTP-ZT 10.9 WATTS / FT 3000K LED 250 LUMENS / FT 0-10V DIMMING DRIVER TO 1%WHITE MEDIA SLAT WALL ACUITY BRANDS CEILING RECESSED. PROVIDE (2) 4'-0" LENGTHS. LC3A 12" LINEAR COVE LIGHT MARK ARCHITECTURAL MARKLINE MKS101-LLP-1FT-MSL1-M100FMC-90CRI-35K-250LMF- 10X60DEG-MIN1-MVOLT-WTP-ZT-MFCLM25L 10.9 WATTS / FT 3500K LED 250 LUMENS / FT 0-10V DIMMING DRIVER TO 1%WHITE MEDIA SLAT WALL ACUITY BRANDS CEILING RECESSED. PROVIDE (2) 1'-0" LENGTHS. LC2 BLUE LED STRIP LIGHT JUNO JFX SERIES JFX 24V 100LM (SECTION LENGTH) RGBW 90CRI WL SLCH 2.2 WATTS 100 LUMEN PER FT N/A ATM VESTIBULE ACUITY BRANDS RECESSED BEHIND ATM MILLWORK PANELS (DESIGNER NOTE: SIZE WILL VARY AND WILL NEED TO BE UPDATED PER PROJECT) LC1D 30" UNDERCABINET STRIP LIGHTING JUNO UPLD UPLD-30IN-SWW4-90CRI-WH 15.3 WATTS 3500K LED 1105 LUMENS STANDARD INCANDESCENT, MAGNETIC LOW VOLTAGE, ELECTRONIC LOW VOLTAGE DIMMERS OR PHASE-CUT DIMMERS WHITE WORKROOM EMPLOYEE ENCLAVE STAFF ROOM MILLWORK NICHES ACUITY BRANDS SURFACE MOUNT UNDER MILLWORK CABINET. DIRECT WIRE PER MANUFACTURER SPECIFICATIONS, REFER TO CUTSHEET. LC1C 22" UNDERCABINET STRIP LIGHTING JUNO UPLD UPLD-22IN-SWW4-90CRI-WH 11.4 WATTS 3500K LED 826 LUMENS STANDARD INCANDESCENT, MAGNETIC LOW VOLTAGE, ELECTRONIC LOW VOLTAGE DIMMERS OR PHASE-CUT DIMMERS WHITE WORKROOM EMPLOYEE ENCLAVE STAFF ROOM MILLWORK NICHES ACUITY BRANDS SURFACE MOUNT UNDER MILLWORK CABINET. DIRECT WIRE PER MANUFACTURER SPECIFICATIONS, REFER TO CUTSHEET. LC1B 14" UNDERCABINET STRIP LIGHTING JUNO UPLD UPLD-14IN-SWW4-90CRI-WH 6.6 WATTS 3000K LED 471 LUMENS STANDARD INCANDESCENT, MAGNETIC LOW VOLTAGE, ELECTRONIC LOW VOLTAGE DIMMERS OR PHASE-CUT DIMMERS WHITE WORKROOM EMPLOYEE ENCLAVE STAFF ROOM MILLWORK NICHES ACUITY BRANDS SURFACE MOUNT UNDER MILLWORK CABINET. LC1A 9" UNDERCABINET STRIP LIGHTING JUNO UPLD UPLD-09IN-SWW4-90CRI-WH 4.5 WATTS 3000K LED 291 LUMENS STANDARD INCANDESCENT, MAGNETIC LOW VOLTAGE, ELECTRONIC LOW VOLTAGE DIMMERS OR PHASE-CUT DIMMERS WHITE WORKROOM EMPLOYEE ENCLAVE STAFF ROOM MILLWORK NICHES ACUITY BRANDS SURFACE MOUNT UNDER MILLWORK CABINET. LA2 24" X 24" RECESSED ARCHITECTURAL TROFFER MARK ARCHITECTURAL WHISPR SERIES WHSPR-2X2-80CRI-35K-4000LM-MIN10-MVOLT-YBC-ZT 32 WATTS 3500K 4000 LUMENS 0-10V DIMMING DRIVER TO 10%STANDARD WHITE GENERAL ACT CEILING ACUITY BRANDS CEILING RECESSED IN ACT. LA1 24" X 48" RECESSED ARCHITECTURAL TROFFER MARK ARCHITECTURAL WHISPR SERIES WHSPR-2X4-80CRI-35K-4000LM-MIN10-MVOLT-YBC-ZT 31 WATTS 3500K 4000 LUMENS 0-10V DIMMING DRIVER TO 10%STANDARD WHITE GENERAL ACT CEILING ACUITY BRANDS CEILING RECESSED IN ACT. EM1 ILLUMINATED EXIT SIGN CHLORIDE ER45VXL-RECESSED CEILING-SINGLE FACE-GW 3.5 WATTS -- -- -- -- 90 MIN. EMERGENCY RUN TIME, GREEN LETTERS, AUTOMATIC SELF-TEST/SELF-DIAGNOSTIC, BATTERY INDICATOR AND BATTERY TEST SWITCH EL3 EXTERIOR LINEAR WALL WASHER MARK ARCHITECTURAL MARKLINE MKS501 LLP xFT MSLx M500FMC BLU 10X60DEG MIN1 MVOLT WTP ZT NOFCL - MCORDGP2 - MDPI4W XX WATTS 4000K LED 0-10V DIMMING DRIVER TO 10%STATIC BLUE LEDS EXTERIOR ACUITY BRANDS RECESSED IN BMO BLUE BAND SIGNAGE. EXTERIOR USE. EL2 EXTERIOR LINEAR WALL WASHER MARK ARCHITECTURAL MARKLINE MKS501 LLP xFT MSLx M500FMC 80CRI 35K 300LMF 10X60DEG MIN1 MVOLT WTP ZT NOFCL XX WATTS 4000K LED 0-10V DIMMING DRIVER TO 10%WHITE DIFFUSER EXTERIOR ACUITY BRANDS RECESSED IN BMO BLUE BAND SIGNAGE. EXTERIOR USE. EL1 6" RECESSED DOWNLIGHT GOTHAM EVO6 EVO6-40/-35-AR-LSS-MD-MVOLT-GZ1-TRW 33.8 WATTS 4000K LED 3500 DELIVERED LUMENS 0-10V DIMMING DRIVER TO 1% CLEAR REFLECTOR SEMI SPECULAR TRIM WHITE FLANGE DRIVE-UP CANOPY ACUITY BRANDS CEILING RECESSED. EXTERIOR USE. TAG TYPE MANUFACTURER MODEL / CATALOG NO. LAMP DRIVER FINISH LOCATION VENDOR MOUNTING / COMMENTS LIGHT FIXTURE SCHEDULE ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 1 1 LL 10/28/2024 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 MILLWORK SCHEDULE BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 02/13/24 222702550 A-605 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 M122-02 EQUIPMENT COUNTER AND WORK SURFACE EMPLOYEE ENCLAVE COUNTER SURFACE: PL-1 NONE PROVIDE GROMMET ON COUNTER SURFACE FOR ACCESS TO POWER BELOW; REFER TO DETAILS ON SHEET A-504. M122-01 WORK SURFACE WITH STORAGE EMPLOYEE ENCLAVE BASE CABINETS: PL-4 UPPER CABINETS: PL-4 COUNTER SURFACE, BACKSPLASH AND TOE KICK: PL-1 PROVIDE LOCKS FOR UPPER CABINETS. KEY UNIQUE FROM OTHER ROOMS. PROVIDE (4) KEYS. PROVIDE LOCKS FOR LOWER FILE CABINET MILLWORK. KEY UNIQUE AND PROVIDE (4) KEYS. PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; PROVIDE HARDWARE INSERTS FOR HANGING FILES AT DRAWERS. PROVIDE GROMMET ON COUNTER SURFACE FOR ACCESS TO POWER AND DATA BELOW; REFER TO DETAILS ON SHEET A-504. M121-05 MEDIA SLAT WALL AB DESKS WOOD SLAT PANELS: PL-21 BACKER PANEL: PL-7 BASE: RB-2 NONE NONE. REFER TO DETAILS SHEET A-506. M121-04 EQUIPMENT COUNTER WITH STORAGE AB DESKS BASE CABINETS: PL-4 UPPER CABINETS: PL-4 COUNTER SURFACE AND TOE KICK: PL-1 PROVIDE LOCKS FOR UPPER AND LOWER CABINETS. M121-01, M121-02, M121-03 AND M121-04 TO BE CONSIDERED ONE MILLWORK GROUP. PROVIDE (4) KEYS.PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; REFER TO DETAILS ON SHEET A-504. M121-03 EQUIPMENT COUNTER WITH STORAGE AB DESKS UPPER CABINETS: PL-4 COUNTER SURFACE: PL-1 PROVIDE LOCKS FOR UPPER CABINETS. M121-01, M121-02, M121-03 AND M121-04 TO BE CONSIDERED ONE MILLWORK GROUP. PROVIDE (4) KEYS PROVIDE ADA COMPLIANT PULLS AT DOORS; REFER TO DETAILS ON SHEET A-504. M121-02 EQUIPMENT COUNTER WITH STORAGE AB DESKS BASE CABINETS: PL-4 UPPER CABINETS: PL-4 COUNTER SURFACE AND TOE KICK: PL-1 PROVIDE LOCKS FOR UPPER AND LOWER CABINETS. M121-01, M121-02, M121-03 AND M121-04 TO BE CONSIDERED ONE MILLWORK GROUP. PROVIDE (4) KEYS.PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; REFER TO DETAILS ON SHEET A-504. M121-01 WORK SURFACE WITH STORAGE AB DESKS BASE CABINETS: PL-4 UPPER CABINETS: PL-4 COUNTER SURFACE AND TOE KICK: PL-1 PROVIDE LOCKS FOR UPPER AND LOWER CABINETS. M121-01, M121-02, M121-03 AND M121-04 TO BE CONSIDERED ONE MILLWORK GROUP. PROVIDE (4) KEYS. KEY LOWER FILE DRAWER SEPARATELY. PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; PROVIDE HARDWARE INSERTS FOR HANGING FILES AT DRAWERS. PROVIDE GROMMET ON COUNTER SURFACE FOR ACCESS TO POWER AND DATA BELOW; M119-01 WORK SURFACE COUPON BOOTH COUNTER SURFACE: PL-3 NONE NONE: REFER TO DETAILS SHEET A-504. M118-01 WORK SURFACE VAULT STORAGE COUNTER SURFACE: PL-1 NONE NONE. M116-01 EQUIPMENT COUNTER WITH SD CARD FILE DRAWERS AND STORAGE CORRIDOR BASE CABINETS: PL-4 UPPER CABINETS: PL-4 COUNTER SURFACE AND TOE KICK: PL-1 PROVIDE LOCKS FOR UPPER AND LOWER CABINETS. KEY UNIQUE FROM OTHER MILLWORK GROUPS, KEY LOWER FILE DRAWERS SEPARATELY. PROVIDE (4) KEYS. PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; PROVIDE HARDWARE INSERTS FOR HANGING FILES AT DRAWERS; REFER TO DETAILS ON SHEET A-504. M111-01 COAT CLOSET ROD AND SHELVES CLOSET SHELVES: PL-4A ROD: STAINLESS STEEL NONE NONE: REFER TO DETAILS SHEET A-505. M110-01 COUNTERS, CABINETS, AND FLOATING SHELF STAFF ROOM BASE CABINETS: PL-5 UPPER CABINETS: PL-4 FLOATING SHELF: PL-6 COUNTER SURFACE: ES-1 TOE KICK: DM-1 NONE PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; REFER TO DETAILS ON SHEET A-504 AND A-505. M107-02 EQUIPMENT COUNTER WITH STORAGE RRB DESKS BASE CABINETS: PL-4 UPPER CABINETS: PL-4 COUNTER SURFACE AND TOE KICK: PL-1 PROVIDE LOCKS FOR UPPER AND LOWER CABINETS. M107-01 AND M107-02 TO BE CONSIDERED ONE MILLWORK GROUP TO BE KEYED ALIKE. KEY UNIQUE FROM OTHER MILLWORK GROUPS. PROVIDE (4) KEYS.PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; REFER TO DETAILS ON SHEET A-504. M107-01 EQUIPMENT COUNTER WITH STORAGE RRB DESKS BASE CABINETS: PL-4 UPPER CABINETS: PL-4 COUNTER SURFACE AND TOE KICK: PL-1 PROVIDE LOCKS FOR UPPER AND LOWER CABINETS. M107-01 AND M107-02 TO BE CONSIDERED ONE MILLWORK GROUP TO BE KEYED ALIKE. KEY UNIQUE FROM OTHER MILLWORK GROUPS. PROVIDE (4) KEYS.PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; REFER TO DETAILS ON SHEET A-504. M104-01 WORK SURFACE WITH EQUIPMENT COUNTER WITH STORAGE WORK ROOM BASE CABINETS: PL-4 UPPER CABINETS: PL-4 COUNTER SURFACE AND TOE KICK: PL-1 PROVIDE LOCKS FOR UPPER CABINETS. LOWER CABINETS DO NOT NEED TO BE LOCKED. KEY UNIQUE FROM OTHER ROOMS. PROVIDE (4) KEYS. PROVIDE ADA COMPLIANT PULL AT DOORS & DRAWERS; REFER TO DETAILS ON SHEET A-504. TAG DESCRIPTION LOCATION FINISHES LOCK/KEY REQUIREMENTS HARDWARE / NOTES MILLWORK SCHEDULE 1 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 LL 10/28/2024 EQUIPMENT SUPPLIER CONTACT LEGEND -SCHEDULES NOT USED DIEBOLD CONTACT: MICHAEL CAVENDER PHONE: (678) 435-5179 EMAIL: MICHAEL.CAVENDER@DIEBOLDNIXDORF.COM THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 EQUIPMENT, APPLIANCE, ACCESSORIES, AND FIXTURE SCHEDULES BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner YYYY.MM.DD 222702550 A-606 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 NOTES: TCR TELLER CASH RECYCLER GLORY GLR-200 - -X X REFER TO ELECTRICAL PLANS FOR POWER AND DATA REQUIREMENTS. SW-C SHELVING WIRE WITH HANGER ROD - -- -- -X X SDS DOUBLE DOOR SD BOX SAFE DIEBOLD NIXDORF MASTERGARD ELITE COMPOSITE SAFE 479-01 DOUBLE DOOR TL-30/350 2 HOUR FIRE RESISTANT X X SB SHRED BIN - -- -- -X X S CASH SAFE DIEBOLD NIXDORF DIEBOLD 275-90 (LARGE CASH SAFE) - -X X PR2 COLOR PRINTER LEXMARK CS820CTE --X X PR1 3-IN-1 PRINTER LEXMARK MX511 --X X ND NIGHT DEPOSIT DIEBOLD NIXDORF 30903 TL-30 - -X X LSQ LOLLIPOP SIGN, QUEUING - -- -- -X X IC INSTA ISSUE CARD MACHINE DATACARD DS4-ES1 - -X X FEC FIRE EXTINGUISHER CABINET JL ACADEMY ALUMINUM 1022V10A - -X X ADA-COMPLIANT FIRE EXTINGUISHER CABINET. WHITE ENAMEL FINISH, VERTICAL DUO GLAZING, APPLIED LETTERING THAT STATES "FIRE EXTINGUISHER". VERIFY SIZE AND COLOR OF LETTERING WITH FIRE MARSHALL. RECOMMENDED EXTINGUISHERS: MP5, DC5, HT5 ETD DRIVE-UP ELECTRIC TRANSACTION DRAWER DIEBOLD NIXDORF 121-30 LARGE CAPACITY ELECTRIC TRANSACTION DRAWER UL LEVEL ONE X X GC TO COORDINATE DSH-75 DIGITAL SCREEN, HORIZONTAL SAMSUNG VARIES - -X X REFER TO PLAN FOR SIZE. G.C TO PROVIDE BLOCKING, AND POWER AND DATA PER PLAN. REFER TO A/V VENDOR DRAWINGS. DSH-65 DIGITAL SCREEN, HORIZONTAL SAMSUNG VARIES - -X X REFER TO PLAN FOR SIZE. G.C TO PROVIDE BLOCKING, AND POWER AND DATA PER PLAN. REFER TO A/V VENDOR DRAWINGS. DUE-3 VEHICLE DETECTION SENSOR E.F. BAVIS AND ASSOCIATES, INC.INTELLIGENT VEHICLE DETECTION SENSOR -X X REFER TO MANUFACTURER'S SPECIFICATIONS AND DRAWINGS FOR INSTALLATION REQUIREMENTS. DESIGNER NOTE: THIS IS TO BE USED FOR EXIST. LOCATIONS/RETROFITS DUE-2 DRIVE-UP PNEUMATIC TUBE DIEBOLD NIXDORF X X GC TO COORDINATE DUE-1 VEHICLE DRIVE-UP DETECTION BELL DIEBOLD NIXDORF X X GC TO COORDINATE CS UNDER COUNTER STEEL CABINET DIEBOLD NIXDORF SU-3-LC/RC-C --X X CG CORNER GUARDS ALEXANDRIA MOULDING AT 008-AM096C03 3/4" x 3/4" x 96" ALUMINUM X X MOUNT AT 4" AFF, ABOVE WALL BASE; TRIM CORNER GUARDS AS REQUIRED TO ALIGN WITH TOP OF HOLLOW METAL DOOR FRAME, UNO. REFER TO EQUIPMENT PLANS FOR LOCATIONS. CB COMPLIANCE BOARD - -- -- -X X BC-2 RECEIVER / CHIME SADOTECH EXPANDABLE SERIES WIRELESS MULTI-UNIT DOORBELL SYSTEM WHITE X X PROVIDE A LAMACOID LABEL AT THE RECEIVER/CHIME AT THE AB DESKS. LABELS SHALL STATE "COUPON BOOTH". INSTALL THE LABEL USING DOUBLE SIDED TAPE ABOVE THE CHIME. REFER TO DETAIL 5/G-101. BC-1 'PUSH FOR ASSISTANCE' BUTTON SADOTECH EXPANDABLE SERIES WIRELESS MULTI-UNIT DOORBELL SYSTEM WHITE X X PROVIDE A LAMACOID LABEL AT THE BUTTON IN COUPON BOOTH. LABEL SHALL STATE "PUSH FOR ASSISTANCE". INSTALL THE LAMACOID LABEL USING DOUBLE SIDED TAPE ABOVE THE BUTTON. PROVIDE BATTERIES AS REQUIRED. SEE DETAIL 5/G-101. ATM ATM AND SURROUND NCR SELFSERV 6684 X X WITH RELOCATED 9527 SURROUND FROM EXISTING BRANCH. BMO VENDOR TO CONFIRM EXISTING SURROUND CAN BE SALVAGED AND REUSED. A5 EXTERIOR THRU-WALL DRIVE-UP ATM NCR SELFSERVE 84 X X GC TO COORDINATE OWNER GC BMO VENDOR OWNER GC BMO VENDOR TAG DESCRIPTION MANUFACTURER MODEL FINISH FURNISHED BY INSTALLED BY NOTES EQUIPMENT SCHEDULE NOTES: 1. GC SHALL PROVIDE PRODUCTS THAT MEET THE PERFORMANCE SPECIFICATION REQUIREMENTS FOR REVIEW AND APPROVAL BY ARCHITECT. 2. ALL APPLIANCES ARE FURNISHED AND INSTALLED BY GC UNLESS NOTED OTHERWISE. WRF WELLNESS ROOM REFRIGERATOR DANBY DESIGN DAR026A2BSLDB STAINLESS STEEL OR APPROVED EQUAL. MUST BE ADA COMPLIANT. S-3 WELLNESS ROOM SINK FRANKE ALBS 6805 STAINLESS STEEL BARRIER FREE DROP IN SINK. MTD MANUAL PULL DOWN TOWEL DISPENSER BOBRICK B-4262 SATIN STAINLESS STEEL KCM COFFEE MAKER - - - -- - PURCHASED AND INSTALLED BY THE BMO BRANCH. KMW MICROWAVE TBD TBD STAINLESS STEEL PRODUCT SHALL MEET THE FOLLOWING PERFORMANCE SPECIFICATIONS: ADA COMPLIANT, BUILT-IN TRIM KIT, 1.4 - 1.5 CU. FT. GC TO COORDINATE SIZE WITH STAFF ROOM MILLWORK. KFR-S COMPACT REFRIGERATOR DANBY DESIGNER DCR12222WDD WHITE PRODUCT SHALL MEET THE FOLLOWING PERFORMANCE SPECIFICATIONS: ADA COMPLIANT, ENERGY STAR RATED, 4.3 CU. FT. GC TO COORDINATE SIZE WITH STAFF ROOM MILLWORK. KFR REFRIGERATOR TBD TBD STAINLESS STEEL PRODUCT SHALL MEET THE FOLLOWING PERFORMANCE SPECIFICATIONS: ADA COMPLIANT, ENERGY STAR RATED, 16.6 - 18.3 CU. FT, BOTTOM FREEZER OR SIDE-BY-SIDE. GC TO COORDINATE SIZE WITH STAFF ROOM MILLWORK. FOR REFRIGERATORS WITH ICE MAKER; GC SHALL ENSURE ICE MAKER IS IN OFF POSITION. KDW DISHWASHER TBD TBD STAINLESS STEEL PRODUCT SHALL MEET THE FOLLOWING PERFORMANCE SPECIFICATIONS: ADA COMPLIANT, ENERGY STAR RATED, DECIBEL LEVEL OF 50 OR BELOW. GC TO COORDINATE SIZE WITH STAFF ROOM MILLWORK. TAG DESCRIPTION MANUFACTURER MODEL FINISH NOTES STAFF ROOM APPLIANCE SCHEDULE NOTES: 1. ALL PLUMBING FIXTURES AND ACCESSORIES ARE TO BE FURNISHED AND INSTALLED BY GC UNLESS NOTED OTHERWISE. WHP WATER HEATER PLATFORM HOLDRITE 50-SWHP-W - - FOR WATER HEATER UP TO 50 GALLONS. CONFIRM WATER HEATER DIAMETER AND REQUIRED CLEARANCES PRIOR TO PURCHASE AND INSTALLATION. WC-4 BARRIER FREE FLOOR-MOUNTED WATER CLOSET - FLUSH VALVE AMERICAN STANDARD MADERA FLOWISE 3043001.020 16-1/2" HEIGHT ELONGATED FLUSHOMETER TOILET WHITE PROVIDE WITH AMERICAN STANDARD 5901.100 WHITE ELONGATED HEAVY DUTY BOWL OPEN FRONT SEAT LESS COVER, AND AMERICAN STANDARD ULTIMA 6047.161.002 MANUAL FLUSH VALVE (1.28 GPF). FLUSH VALVE TO BE LOCATED ON OPEN SIDE OF WATER CLOSET. WC-3 BARRIER FREE WALL-MOUNTED WATER CLOSET - TANK TYPE AMERICAN STANDARD GLENWALL VORMAX ELONGATED TOILET 2882107 WITH SEAT 5901100 WHITE PROVIDE WITH AMERICAN STANDARD 3447101 ELONGATED HEAVY DUTY BOWL OPEN FRONT SEAT LESS COVER. FLUSH CONTROL TO BE LOCATED ON OPEN SIDE OF WATER CLOSET. WC-2 BARRIER FREE FLOOR-MOUNTED WATER CLOSET - TANK TYPE AMERICAN STANDARD CADET PRO RIGHT HEIGHT ELONGATED TOILET 215AA.104 WHITE PROVIDE WITH AMERICAN STANDARD 5901.100 WHITE ELONGATED HEAVY DUTY BOWL OPEN FRONT SEAT LESS COVER. FLUSH CONTROL TO BE LOCATED ON OPEN SIDE OF WATER CLOSET. USE ONLY WHERE SIZE/PRESSURE OF EXISTING WATER LINE DOES NOT ALLOW FOR FLUSH VALVE TOILET. WC-1 BARRIER FREE FLOOR-MOUNTED WATER CLOSET - FLUSH VALVE AMERICAN STANDARD MADERA FLOWISE 3043.001 16-1/2" HEIGHT ELONGATED FLUSHOMETER TOILET WHITE PROVIDE WITH AMERICAN STANDARD 5901.100 WHITE ELONGATED HEAVY DUTY BOWL OPEN FRONT SEAT LESS COVER, AND AMERICAN STANDARD ULTIMA 6047.161.002 MANUAL FLUSH VALVE. FLUSH VALVE TO BE LOCATED ON OPEN SIDE OF WATER CLOSET. SSH INDUSTRIAL SHELVING UNIT SIAVANCE CHROME 6-TIER CORNER UTILITY SHELVING UNIT 20"W x 20"D x 72"H CHROME 6 SHELVES S-9 HI-LOW DRINKING FOUNTAIN W/ INTEGRATED WATER REFILL STATION ELKAY EZWS-ERPBM28K STAINLESS STEEL HARDWIRED CONNECTION, SEE ELECTRICAL DRAWINGS. GC TO COORDINATE WITH CLIENT PROJECT MANGER TO DETERMINE IF WATER FILTER WILL BE REQUIRED. S-7 WATER REFILL STATION ELKAY EZWSM8PK STAINLESS STEEL HARDWIRED CONNECTION, SEE ELECTRICAL DRAWINGS. GC TO COORDINATE WITH CLIENT PROJECT MANGER TO DETERMINE IF WATER FILTER WILL BE REQUIRED. S-5 HI-LOW DRINKING FOUNTAIN ELKAY ERPBGRNM28K STAINLESS STEEL HARDWIRED CONNECTION, SEE ELECTRICAL DRAWINGS. GC TO COORDINATE WITH CLIENT PROJECT MANGER TO DETERMINE IF WATER FILTER WILL BE REQUIRED. S-2 STAFF ROOM SINK ELKAY LUSTERSTONE CLASSIC ELUHAD211550 STAINLESS STEEL S-1 ELECTRIC HANDS-FREE STAFF ROOM SINK FAUCET AMERICAN STANDARD BEALE 4931.380 PULL-DOWN KITCHEN FAUCET POLISHED CHROME 002 HAND-OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM. PROVIDE OPTIONAL AC ADAPTER FOR POWER SOURCE; SEE ELECTRICAL DRAWINGS. FLOW RATE: 1.5 GPM. MS-2 MOP SINK FAUCET CHICAGO FAUCETS 956-XKCP - - MS-1 MOP SINK STERN - WILLIAMS MTB-2424 SQUARE BASIN - - PROVIDE SQUARE CAST BRASS DRAIN, A-20 BUMPER GUARD, AND T-35 HOSE AND WALL HOOK. MH 3-STATION WALL MOUNT MOP HOLDER ELKAY LK403 STAINLESS STEEL COORDINATE EXACT LOCATION ON SITE. MOUNT AT 4'-10" A.F.F. TO CENTERLINE. L-2 ELECTRONIC NO-TOUCH LAVATORY FAUCET WITH INFRARED SENSOR SLOAN OPTIMA SENSOR FAUCET EAF-200-PLG POLISHED CHROME FLOW RATE: 0.5 GPM MAX. AT 60 PSI. PROVIDE HARDWIRED CONNECTION. L-1 BARRIER FREE RESTROOM SINK AMERICAN STANDARD MEZZO SEMI-COUNTERTOP SINK 9960.001 WHITE MOUNT AT 34" MAXIMUM AFF TO TOP OF RIM. TAG DESCRIPTION MANUFACTURER MODEL FINISH NOTES PLUMBING AND JANITOR FIXTURE SCHEDULE NOTES: 1. REFER TO RESTROOM PLANS, ELEVATIONS, AND TYP ACCESSIBILITY DETAILS FOR MOUNTING LOCATIONS AND HEIGHTS. 2. ALL ACCESSORIES ARE TO BE FURNISHED AND INSTALLED BY THE GC UNLESS NOTED OTHERWISE. TTD TOILET TISSUE DISPENSER FROST 156-S STAINLESS STEEL TSC TOILET SEAT COVER DISPENSER FROST 199-S STAINLESS STEEL SD SOAP DISPENSER - - - -- - PROVIDED AND INSTALLED BY BMO FACILITIES TEAM. MIR MIRROR FROST 941-2436 STAINLESS STEEL MOUNT AT 40" A.F.F. MAXIMUM TO BOTTOM OF REFLECTING SURFACE. GB GRAB BARS FROST 1001-SP SERIES BRUSHED STAINLESS STEEL PROVIDE (1) 42" GRAB BAR, (1) 36" GRAB BAR PER RESTROOM SND SANITARY NAPKIN DISPOSAL FROST 622 STAINLESS STEEL CTD COMBINATION TOWEL DISPENSER / WASTE RECEPTACLE FROST 410-B STAINLESS STEEL SEMI - RECESSED CH COAT HOOK FROST 1150-SS STAINLESS STEEL PROVIDE TWO COAT HOOKS PER RESTROOM. TAG DESCRIPTION MANUFACTURER MODEL FINISH NOTES RESTROOM ACCESSORIES SCHEDULE 1 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 ISSUED FOR CLIENT REVIEW AW DR 2024/09/06 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 1 PLAN CHECK #2 SS DR 2024/10/28 1 LL 10/28/2024 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO. SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BANKING HALL VIEWS BMO BANK N.A. TENANT IMPROVEMENT Author CheckerDesigner 09/07/24 222702550 A-607 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 SCALE SCALE SCALE SCALEBANKING HALL VIEW 1 1BANKING HALL VIEW 2 2 BANKING HALL VIEW 4 4 BANKING HALL VIEW 3 3 ISSUED FOR PERMIT AND BID AV DR 2024/09/16 LL 10/28/2024 345 POLLASKY AVE. CLOVIS, CALIFORNIA 93612 PHONE: (559) 323-9600 FAX: (559) 323-9633 S T R U C T U R A L E N G I N E E R I N G BRAD YOUNG & ASSOCIATES, INC. BYA JOB # 24622 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION BYA PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 24622 2024/09/05ISSUED FOR CLIENT REVIEW 2024/09/13ISSUED FOR PERMIT AND BID PLAN CHECK #2 2024/10/28 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT W 345 POLLASKY AVE. CLOVIS, CALIFORNIA 93612 PHONE: (559) 323-9600 FAX: (559) 323-9633 S T R U C T U R A L E N G I N E E R I N G BRAD YOUNG & ASSOCIATES, INC. BYA JOB # 24622 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION BYA PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 24622 2024/09/05ISSUED FOR CLIENT REVIEW 2024/09/13ISSUED FOR PERMIT AND BID PLAN CHECK #2 2024/10/28 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT STANDARD NOTES AND DETAILS NOT USED 345 POLLASKY AVE. CLOVIS, CALIFORNIA 93612 PHONE: (559) 323-9600 FAX: (559) 323-9633 S T R U C T U R A L E N G I N E E R I N G BRAD YOUNG & ASSOCIATES, INC. BYA JOB # 24622 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION BYA PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 24622 2024/09/05ISSUED FOR CLIENT REVIEW 2024/09/13ISSUED FOR PERMIT AND BID PLAN CHECK #2 2024/10/28 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT FOUNDATION PLAN 345 POLLASKY AVE. CLOVIS, CALIFORNIA 93612 PHONE: (559) 323-9600 FAX: (559) 323-9633 S T R U C T U R A L E N G I N E E R I N G BRAD YOUNG & ASSOCIATES, INC. BYA JOB # 24622 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION BYA PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 24622 2024/09/05ISSUED FOR CLIENT REVIEW 2024/09/13ISSUED FOR PERMIT AND BID PLAN CHECK #2 2024/10/28 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT 2nd FLOOR FRAMING PLAN S2.2 FIXTURE DETAILS S3.1 345 POLLASKY AVE. CLOVIS, CALIFORNIA 93612 PHONE: (559) 323-9600 FAX: (559) 323-9633 S T R U C T U R A L E N G I N E E R I N G BRAD YOUNG & ASSOCIATES, INC. BYA JOB # 24622 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION BYA PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 24622 2024/09/05ISSUED FOR CLIENT REVIEW 2024/09/13ISSUED FOR PERMIT AND BID PLAN CHECK #2 2024/10/28 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT 345 POLLASKY AVE. CLOVIS, CALIFORNIA 93612 PHONE: (559) 323-9600 FAX: (559) 323-9633 S T R U C T U R A L E N G I N E E R I N G BRAD YOUNG & ASSOCIATES, INC. BYA JOB # 24622 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION BYA PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 24622 2024/09/05ISSUED FOR CLIENT REVIEW 2024/09/13ISSUED FOR PERMIT AND BID PLAN CHECK #2 2024/10/28 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT FIXTURE DETAILS S3.2 DRAWING INDEX DWG DESCRIPTION M000 COVER SHEET, DRAWING INDEX M001 SCHEDULES & DETAILS M100 MECHANICAL DEMO PLAN M200 HVAC PLAN M201 ROOF PLAN M300 MECHANICAL CONTROL PLAN M400 TITLE 24 M500 EQUIPMENT SPECIFICATIONS M501 EQUIPMENT SPECIFICATIONS 90° DIVERGING RECTANGULAR TEE, EITHER RADIUS OR TURNING VANES PARALLEL FLOW BRANCH CONNECTION, EITHER RADIUS OR TURNING VANES Ø ROUND DUCT INDICATOR 90° RECTANGULAR TAKE-OFF WITH 45° TAPER WYE FITTING TRANSITION OR REDUCER (FOT = FLAT ON TOP, FOB = FLAT ON BOTTOM) 45° LATERAL TAKE-OFF 90° CONICAL TAKE-OFF 90° TAKE-OFF OR TEE FD FD FIRE DAMPER (--<| = HORIZ DUCT, --<> = VERT DUCT), 2-HR RATED, UON 90° ELBOW, R/D OR R/W=1.5 SQUARE CORNER ELBOW WITH TURNING VANES FIRE/SMOKE DAMPER (--<| = HORIZ DUCT, --<> = VERT DUCT), 2-HR RATED, UON FSD FSD VOLUME DAMPER UPUPUP DUCT PENETRATION THRU FLOOR OR ROOF DOWNUP DUCT SECTION, POSITIVE PRESSURE UP DOWN DUCT SECTION, NEGATIVE PRESSURE UP ROUND DUCT SECTION DOWN T ROOM THERMOSTAT OR TEMPERATURE TRANSMITTER DSD DUCT SMOKE DETECTOR TRANSFER GRILLE, CEILING MOUNTED WITH FULL-SIZED LINED DUCT CONNECTION 50 TRANSFER GRILLE (TG), DUCT CONNECTED, WALL MOUNTED W/ OPTIONAL CFM SHOWN CEILING DIFFUSER (FLOW ARROWS SHOWN FOR NON SYMMETRICAL AIRFLOW) CEILING RETURN/EXHAUST GRILLE LINEAR DIFFUSER, CEILING OR WALL MOUNTED (FLOW ARROWS SHOWN FOR NON SYMMETRICAL AIRFLOW) WALL SUPPLY GRILLE (SG) WALL RETURN/EXHAUST GRILLE (RG, EG) PIPE CAP PIPE PLUG UNION FLANGE GATE VALVE OR BALL VALVE BALL VALVE PRESSURE REDUCING VALVE (PRV) BREAK IN PIPING OR DUCTWORK H ROOM HUMIDISTAT OR HUMIDITY TRANSMITTER CO CARBON MONOXIDE SENSOR CD CONDENSATE DRAINAGE PIPING TYPICAL EQUIPMENT DESIGNATION (EXHAUST FAN SHOWN) EQUIPMENT EF-1 CD-1 400 CD-12x12 400 OR DIFFUSER/GRILLE TYPE, AND NUMBER OR SIZE DESIGN CFM (WHERE APPLICABLE) TERMINALS 18x12 DUCT (1ST FIGURE = SIDE SHOWN, 2ND FIGURE = SIDE NOT SHOWN) DUCTWORK SD SMOKE DETECTOR FLEXIBLE DUCT G NATURAL GAS - STD. PRESSURE NATURAL GAS - MEDIUM PRESSUREMPG CHECK VALVE ACU AIR CONDITIONING UNIT AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AP ACCESS PANEL BDD BACKDRAFT DAMPER BHP BRAKE HORSEPOWER BTUH BRITISH THERMAL UNIT PER HOUR C COMMON CAP CAPACITY CC COOLING COIL CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CLG CEILING, COOLING CO CLEANOUT COMB COMBUSTION CONT CONTINUE, CONTROL COP COEFFICIENT OF PERFORMANCE CWS CHILLED/CONDENSER WATER SUPPLY CWR CHILLED/CONDENSER WATER RETURN D DIAMETER DB DRY BULB, DECIBEL DIM DIMENSION DISCH DISCHARGE DN DOWN EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY EG EXHAUST GRILLE ELEC ELECTRIC ESP EXTERNAL STATIC PRESSURE EXH EXHAUST EXT EXTERIOR, EXTERNAL F FAHRENHEIT FCU FAN COIL UNIT FLR FLOOR FPM FEET PER MINUTE FPS FEET PER SECOND FSD FIRE/SMOKE DAMPER G GAS GAL GALLONS GPM GALLONS PER MINUTE GRD GRILLES, REGISTERS, DIFFUSERS GWB GYPSUM WALLBOARD HD HEAD HORIZ HORIZONTAL HP HORSEPOWER HPU HEAT PUMP UNIT HRU HEAT RECOVERY UNIT HVAC HEATING, VENTILATING, AND AIR CONDITIONING HVU HEATING & VENTILATION UNIT HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER ID INDIRECT DRAIN, INSIDE DIAMETER IN INCH KW KILOWATT L LONG, LENGTH LB POUND MBH THOUSAND BTU PER HOUR MECH MECHANICAL MCA MIN. CIRCUIT AMPACITY MOCP MAX. OVER CURRENT PROTECTION MTD MOUNTED OSA OUTDOOR AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION OR DIAMETER OPNG OPENING P PUMP PD PRESSURE DROP, PUMPED DRAIN POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PSIG POUNDS PER SQUARE INCHGAUGE RA RETURN AIR RD ROOF DRAIN REF REFERENCE RF RELIEF FAN RG RETURN GRILLE RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SCH SCHEDULE SF SUPPLY FAN, SQUARE FOOT SENS SENSIBLE SG SUPPLY GRILLE SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION SO SCREENED OPENING SP STATIC PRESSURE SS STAINLESS STEEL, SANITARY SEWER SQ SQUARE TG TRANSFER GRILLE TYP TYPICAL UH UNIT HEATER UON UNLESS OTHERWISE NOTED V VENT VENT VENTILATION, VENTILATOR VTR VENT THRU ROOF W WASTE, WATT, WIDE WB WET BULB (TEMPERATURE) RAIN LEADER (RL)RL OVERFLOW RAIN LEADER (OL)OL GENERAL NOTES - MECHANICAL 1.REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE WORK COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL, CIVIL, ELECTRICAL, LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY). 2.ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC. OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED. 3.CODES: COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE APPLICABLE BUILDING, MECHANICAL, ENERGY, PLUMBING, FIRE, AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. 4.PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL STRUCTURAL SHOP DRAWINGS FOR LOCATING AND ROUTING ALL DUCTWORK, DAMPERS, EQUIPMENT, PIPING, ETC. A.COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL. B.COORDINATE FINAL LOCATION AND ROUTING WITH CEILING, LIGHTS, WALLS, FIRE SPRINKLER PIPING, AND OTHER TRADES WORK. C.INCLUDE ADDITIONAL OFFSETS, ELBOWS, ROUTING, EQUIVALENT DUCT SIZING EXCHANGE, RELOCATING, ETC. AS REQUIRED FOR A COMPLETE OPERATING MECHANICAL SYSTEM. D.PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. 5.MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE. 6.ACCESS DOORS: COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. VERIFY ACCESS DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO BIDDING. 7.RATED PENETRATION: DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE/SMOKE DAMPERED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES(UL) FIRE RESISTANCE WITH HOURLY RATINGS FOR THROUGH-PENETRATION FIRE STOPS SYSTEM VOLUME #2, OR SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S UL LISTINGS (3M OR EQUIVALENT). DETERMINE REQUIREMENTS WITH GENERAL CONTRACTOR PRIOR TO BID. 8.EXHAUST OUTLETS: SOURCE-SPECIFIC FANS SHALL BE VENTED TO OUTDOORS WITH A MINIMUM 3' CLEARANCE BETWEEN VENT OUTLETS AND BUILDING OPENINGS, AND 10' MINIMUM BETWEEN VENT OUTLETS AND MECHANICAL AIR INTAKES. 9.ROOF PENETRATIONS: SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP, ROOF CURB, ROOF DRAIN, AND VTR DETAILS. 10.EXPOSED PIPING: PROVIDE CHROME PLATING FOR EXPOSED PIPING IN FINISHED ROOMS. 11.PENETRATIONS: PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK PENETRATIONS. 12.SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND PENETRATIONS IN AIR PLENUMS. 13.LIGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND REPLACEMENT. 14.CABLE TRAYS: DUCTWORK AND PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" ABOVE AND TO THE SIDE OF CABLE TRAYS. 15.MOTORS: COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM EFFICIENCIES UNDER FULL LOAD. 16.ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. COORDINATION REQUIREMENTS 1.PIPING: COORDINATE WITH STRUCTURAL FOR EXACT LOCATION OF ALL STRUCTURAL FRAMING AND FOOTINGS AND FINALIZE THE EXACT ROUTING OF ALL PIPES WITH STRUCTURAL AND AT THE SITE PRIOR AND DURING THE CONSTRUCTION. 2.DUCTWORK: LOCATE AND COORDINATE THE EXACT LOCATION OF DUCTWORK WITH STRUCTURAL PLANS AND WITH THE GENERAL CONTRACTOR PRIOR TO INSTALLATION OF ANY STRUCTURE OR EQUIPMENT. COORDINATE WITH FRAMING CONTRACTOR TO ASSURE JOIST SPACES LINE UP WHEN DUCTWORK MUST PASS THROUGH DIFFERENT JOIST SPACES. 3.ADJUSTMENTS: ALL EQUIPMENT, MOTORS, FANS GAS BURNERS, IGNITION DEVICES, DRIVES, ETC. SHALL BE ADJUSTED AND BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL. 4.APPROVALS: MECHANICAL AND PLUMBING EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH HIS MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THESE REQUIREMENTS IN HIS BID. 5.FIRE PROTECTION: CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PROTECTION SPRINKLER SYSTEM IN COMPLIANCE WITH NFPA AND LOCAL CODES. PROVIDE DESIGN, PERMITS, MATERIALS, INSTALLATION, TESTING AND ALL OTHER FOR A FULLY OPERATIONAL SYSTEM. LOCATION OF ALL PIPING TO BE COORDINATED WITH OTHER TRADES. 6.FIREPLACES: COORDINATE WITH THE GENERAL CONTRACTOR TO DETERMINE GAS FIREPLACE FLUE AND COMBUSTION AIR DUCTWORK REQUIREMENTS PRIOR TO BIDDING. PIPING NOTES 1.DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. 2.REDUCERS: PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION SIZES. 3.OFFSETS: PROVIDE FOR BRANCH LINES TO EQUIPMENT. 4.DIELECTRIC UNIONS: PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. 5.REFRIGERANT PIPING: PROVIDE SIZING & INSTALLATION IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 6.CONDENSATE DRAIN: PROVIDE A P-TRAP FOR EACH HVAC UNIT CONDENSATE PAN WITH PLUG TEES FOR CLEANING. CONDENSATE DRAINS SHALL BE DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. DRAWINGS ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. CONTRACTORS SHALL ATTEND A PRE-CONSTRUCTION MEETING WITH THE ENGINEER FOR THE PURPOSE OF REVIEWING THE WORK PRIOR TO ORDERING ANY EQUIPMENT OR PERFORMING ANY WORK. THE MEETING SHALL BE LOCATED AT THE PROJECT SITE ON A DATE AND TIME TO BE MUTUALLY AGREED. THE MEETING WILL BE A WORKING SESSION. THE MEETING WILL BE FACILITATED BY THE ENGINEER AND THE AGENDA WILL INCLUDE A DETAILED REVIEW OF THE PLANS AND SPECIFICATIONS, CROSS CHECK WITH OTHER TRADES FOR COORDINATION ISSUES, REVIEW OF PROPOSED PRODUCTS, REVIEW OF PLANNED MEANS AND METHODS,AND ON-SITE INVESTIGATION OF FIELD CONDITIONS RELATIVE TO EXISTING CONDITIONS THAT COULD AFFECT THE WORK. PERSONS ATTENDING THE MEETING SHALL BE KNOWLEDGEABLE OF THE PROJECT AND SHALL BE THE SPECIFIC PERSONS INTENDED TO CONTINUE WITH THE PROJECT THROUGH TO COMPLETION. IF REQUIRED, REVISED PLANS WILL BE ISSUED THROUGH OFFICIAL CHANNELS. CHANGES IN THE BID PRICE WILL BE DISCUSSED, BUT NO CHANGE ORDERS WILL BE ISSUED UNLESS PROCESSED THOUGH OFFICIAL CHANNELS. IT SHALL BE UNDERSTOOD THAT THE ENGINEER HAS NO AUTHORITY TO ISSUE CHANGE ORDERS. THE FOLLOWING TRADES SHALL BE REPRESENTED FOR THE MINIMUM TIME INDICATED: MECHANICAL SHEET METAL 4 HOURS PLUMBING/PIPING 4 HOURS ELECTRICAL 4 HOURS SPRINKLER 2 HOURS GENERAL CONTRACTOR ALL SESSIONS DRAWING INDEX PRE-CON MEETING NOTES SYMBOLSABBREVIATIONSGENERAL NOTES INSULATION/LINING NOTES 1.ENERGY CODE: AS A MINIMUM, COMPLY WITH THICKNESSES AND TYPES LISTED IN ENERGY CODE ENFORCED BY AHJ. PLAN NOTES 1.DUCTWORK SHALL BE METALLIC DUCTWORK 2.TEST AND BALANCE WORK SHALL BE PERFORMED BY AN INDEPENDENT TEST AND BALANCE AGENCY. PROVIDE (3) COPIES OF TEST AND BALANCE REPORT TO OWNER. 3.COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN CEILING SPACE. 4.RESTROOM EXHAUST SHALL BE A MINIMUM OF 10' FROM ANY MECHANICAL OUTSIDE AIR INTAKES. 5.ROUTE DUCTWORK UNDERNEATH JOISTS UON. 6.TRANSITION DUCT UNDER BEAMS AND DUCTS. FIELD VERIFY AVAILABLE CEILING CAVITY DIMENSIONS. 7.COORDINATE MOUNTING HEIGHT OF DIFFUSERS WITH ARCHITECTURAL PLANS. SHEET METAL NOTES 1.REFERENCE: SMACNA HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE, CURRENT EDITION. 2.CLEARANCE: COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN CEILING SPACE. 3.ROUND ELBOWS AND OFFSETS: FULL RADIUS (R/D = 1.5), 5-PIECE SEGMENTED OR STAMPED. REFER TO SMACNA HVACDCS FIG 2-7, 3-3. DO NOT USE ANGLED OFFSET (TYPE 1). MITERED OFFSET (TYPE 2) MAY BE USED UP TO 30 DEGREE OFFSET ANGLE. 4.ROUND TEES AND LATERALS: CONICAL TEE PER SMACNA HVACDCS FIG 3-5; DO NOT USE STRAIGHT TEE; DO NOT USE CONICAL SADDLE TAP FOR EXPOSED DUCTWORK IN FINISHED SPACES. 90-DEGREE TEE WITH OVAL TO ROUND TAP, LATERAL, AND 45-DEGREE RECTANGULAR LEAD-IN PER SMACNA HVACDCS FIG 3-4. 5.RECTANGULAR ELBOWS AND OFFSETS: FULL RADIUS WHERE SPACE PERMITS, R/W = 1.5; OTHERWISE USE SQUARE CORNER ELBOW WITH TURNING VANES. 6.RECTANGULAR DIVIDED FLOW FITTINGS: USE GENERALLY, EXCEPT BRANCHES TO TERMINALS; SMACNA HVACDCS FIG 2-5, TYPES 1, 2, 4A, AND 4B. DO NOT USE TYPE 3. 7.TURNING VANES: H.E.P. MANUFACTURER OR APPROVED HIGH EFFICIENCY PROFILE AIRFOIL TYPE FOR RECTANGULAR SQUARE THROAT ELBOWS. ACOUSTICAL TYPE FOR RETURN AIR MITERED ELBOWS. 8.TAKEOFFS TO OPENINGS: CONICAL TYPE WITH VOLUME DAMPER FOR ROUND DUCT BRANCHES PER SMACNA HVACDCS FIG 2-6, MINIMUM INLET DIAMETER 2 INCHES LARGER THAN DUCT SIZE. 45 DEGREE ENTRY FITTING FOR RECTANGULAR DUCT BRANCHES PER SMACNA HVACDCS FIG 2-6. 9.FLEXIBLE CONNECTIONS: PROVIDE AT EACH DUCT CONNECTION TO FANS, PACKAGED HVAC EQUIPMENT, EXTERNALLY ISOLATED AIR HANDLING UNITS, FAN COIL UNITS, AND SIMILAR EQUIPMENT. EXCEPTION: EQUIPMENT IN CORRIDOR CEILING SPACES WHERE FIRE RATING IS REQUIRED. HVAC NOTES 1.ATTACHMENTS: AIR DISTRIBUTION OUTLETS AND LOUVERS SHALL HAVE ALL REQUIRED ACCESSORIES AND ATTACHMENTS FOR A COMPLETE CONNECTION TO THE SPECIFIC TYPE OF STRUCTURE THAT THEY ARE BEING ATTACHED TO. THIS INCLUDES, BUT IS NOT LIMITED TO, EXTERIOR BRICKS, GWB WALLS, GWB CEILING, ETC. 2.DUCTWORK: DUCTWORK SHALL BE SMOOTH SHEET METAL (CLASS-1). DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE MIN. 26 GA. STEEL. MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 5'-0", UNLESS OTHERWISE NOTED ON DRAWINGS. DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 3.VOLUME DAMPERS: PROVIDE AN ACCESSIBLE MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, OSA, AND EXHAUST OPENING, LOCATED AS FAR UPSTREAM AS POSSIBLE FROM THE OPENING. PROVIDE A MANUAL VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE OPENING. VOLUME DAMPERS IN NON-ACCESSIBLE CEILINGS SHALL HAVE A CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION. 4.SEISMIC: PROVIDE SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT, PIPING, AND DUCTWORK PER SMACNA AND LOCAL REGULATIONS. 5.FILTER CLEARANCE: PROVIDE ADEQUATE CLEARANCE FOR CHANGING AIR FILTERS. 6.DUCTWORK AND PIPING OUTSIDE OF MECHANICAL ROOMS SHALL BE CONCEALED, COORDINATE WITH THE GENERAL CONTRACTOR TO FUR-OUT AS REQUIRED. 7.FIRE RATINGS: RATED FLOOR/CEILING JOINT SPACES HAVING DUCTWORK INSIDE THEM SHALL BE FIRE/SMOKE PROTECTED TO MAINTAIN THE 1-HOUR FLOOR/CEILING RATING PER LOCAL JURISDICTIONS. EXHAUST DUCTWORK PENETRATING THE 1-HOUR ROOF/CEILING OR FLOOR/CEILING ASSEMBLY SHALL HAVE ACCESSIBLE CEILING FIRE DAMPERS. ALTERNATIVELY, THE EXHAUST DUCTWORK SHALL BE ROUTED INSIDE A RATED SHAFT TO PROTECT THE CEILING/ROOF RATING PER THE LOCAL JURISDICTIONS. 8.FIRESTOP: PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 9.CORRIDOR THERMOSTAT: PROVIDE TAMPERPROOF THERMOSTATS IN CORRIDORS. DO NOT PROVIDE PLASTIC GUARDS TO MAKE THE THERMOSTATS TAMPERPROOF. PROVIDE BLANK SECURABLE THERMOSTAT COVERS. 10.EQUIPMENT REQUIRED TO INTEGRATE INTO THE BAS MUST BE CONFIGURED BY THE ORIGINAL EQUIPMENT MANUFACTURER (OEM) FOR THIS INTEGRATION TO OCCUR. THIS INCLUDES COMMUNICATION VIA OPEN PROTOCOL BACNET AND PROGRAMMING BY THE OEM INCLUDING CONFIGURING NETWORK ADDRESSING COMPATIBLE WITH EXISTING EQUIPMENT ON-SITE AND ANY TECHNICAL SUPPORT REQUIRED TO FACILITATE THIS. CONTRACTOR SUBSTITUTIONS & REVISIONS: PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS FOR REVIEW AND APPROVAL PRIOR TO ORDERING MATERIAL OR DOING WORK. FOR EQUIPMENT THAT IS SCHEDULED BY MANUFACTURER'S NAME AND CATALOG DESIGNATIONS, THE MANUFACTURER'S PUBLISHED DATA AND/OR SPECIFICATION FOR THAT ITEM ARE CONSIDERED PART OF SPECIFICATION. ENGINEERING COSTS FOR REVISING MEP PLANS SHALL BE ADDRESSED IN THE COST ANALYSIS OF THE SUBSTITUTION PROPOSAL. CONTRACTOR TO COORDINATE WITH ENGINEER AND DETERMINE ASSOCIATED DESIGN AND PERMITTING COSTS. CONTRACTOR SHALL BE RESPONSIBLE FOR OTHER COSTS ASSOCIATED WITH UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS OR REVISIONS. CONTRACTOR SUBSTITUTIONS & REVISIONS PROJECT NOTES 1.THE PERSON WITH OVERALL RESPONSIBILITY FOR CONSTRUCTION OR THE PERSON RESPONSIBLE FOR THE INSTALLATION OF REGULATED FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES SHALL POST, OR MAKE AVAILABLE WITH THE BUILDING PERMIT(S) ISSUED FOR THE BUILDING, THE REQUIRED INSTALLATION CERTIFICATE(S) FOR FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES REGULATED BY THE APPLIANCE EFFICIENCY REGULATIONS OR PART 6. SUCH INSTALLATION CERTIFICATE(S) SHALL BE MADE AVAILABLE TO THE ENFORCEMENT AGENCY FOR ALL APPROPRIATE INSPECTIONS. THESE CERTIFICATES SHALL: 1.1.IDENTIFY FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES REQUIRED TO VERIFY COMPLIANCE WITH THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6. 1.2.INCLUDE A STATEMENT INDICATING THAT THE FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES CONFORM TO THE APPLIANCE EFFICIENCY REGULATIONS AND PART 6 AND THE REQUIREMENTS FOR SUCH FEATURES, MATERIALS, COMPONENTS, OR MANUFACTURED DEVICES GIVEN IN THE PLANS AND SPECIFICATIONS APPROVED BY THE LOCAL ENFORCEMENT AGENCY. 1.3.STATE THE NUMBER OF THE BUILDING PERMIT UNDER WHICH THE CONSTRUCTION OR INSTALLATION WAS PERFORMED. 2.AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND SPECIFICATIONS DESCRIBED IN SEC. 10-103 (A) 2. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME, MATERIAL IDENTIFICATION, AND THE INSTALLED R-VALUE. 3.WITHIN 90 DAYS AFTER ISSUANCE OF CERTIFICATE OF OCCUPANCY RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER. IF ANY CHARACTERISTIC IS MATERIALLY CHANGED BEFORE FINAL CONSTRUCTION AND INSTALLATION, SUCH THAT THE BUILDING MAY NO LONGER COMPLY WITH PART 6, THE BUILDING MUST BE BROUGHT INTO COMPLIANCE, AND SO INDICATED ON AMENDED PLANS AND CERTIFICATE OF COMPLIANCE THAT SHALL BE SUBMITTED FOR PLAN APPROVAL. 4.THE BUILDER SHALL PROVIDE THE BUILDING OWNER OR THE PERSON(S) RESPONSIBLE FOR BUILDING MAINTENANCE (IN CASE OF MULTI-TENANT OR CENTRALLY OPERATED BUILDINGS) AT OCCUPANCY THE FOLLOWING: 4.1.OPERATING INFORMATION: THE APPROPRIATE CERTIFICATE(S) OF COMPLIANCE AND A LIST OF THE FEATURES, MATERIALS, COMPONENTS, AND MECHANICAL DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO OPERATE THEM EFFICIENTLY. 4.2.MAINTENANCE INFORMATION: REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING THE OPERATION AND MAINTENANCE MANUAL. 4.3.VENTILATION INFORMATION: A DESCRIPTION OF THE QUANTITIES OF OUTDOOR AND RECIRCULATED AIR THAT THE VENTILATION SYSTEMS ARE DESIGNED TO PROVIDE TO EACH AREA. 5.ANY ROOFING PRODUCT USED AS A COOL ROOF SHALL BE CERTIFIED AND LABELED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 10-113 BY THE COOL ROOF RATING COUNCIL (CRRC) AND MEET CONDITIONS SET IN SEC. 118 (I). 6.DUCT SYSTEMS USED WITH BLOWER TYPE EQUIPMENT WHICH ARE PORTIONS OF A HEATING, COOLING, ABSORPTION, EVAPORATIVE COOLING OR OUTDOOR AIR VENTILATION SYSTEM SHALL BE SIZED IN ACCORDANCE WITH CHAPTER 17 OF THE CALIFORNIA MECHANICAL CODE. 7.SUPPLY AIR, RETURN AIR, AND OUTSIDE AIR FOR HEATING, COOLING, OR EVAPORATIVE COOLING SYSTEMS SHALL BE CONDUCTED THROUGH DUCT SYSTEMS CONSTRUCTED OF METAL AS SET FORTH IN THE ANSI/SMACNA 006-2006 HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE, OR ANOTHER APPROVED DUCT CONSTRUCTION STANDARD. 8.MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME-SPREAD INDEX NOT GREATER THAN TWENTY-FIVE (25) AND A SMOKE DEVELOPED INDEX NOT GREATER THAN FIFTY (50) WHEN TESTED AS A COMPOSITE PER APPLICABLE TESTING STANDARD. 9.WHEN FIRE DETECTION OR ALARM SYSTEMS ARE PROVIDED FOR THE BUILDING, ANY REQUIRED SMOKE DETECTORS SHALL BE SUPERVISED BY SUCH SYSTEMS AND SHALL BE CAPABLE OF ACTIVATING THE FIRE ALARM SYSTEM. 10.REFRIGERANT SERVICE PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING TYPE TAMPER RESISTANT CAPS OR SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS BY AN ACCEPTABLE MEANS. 11.ALL APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE PER BUILDING CODE REQUIREMENTS OR APPLICABLE MANUFACTURER INSTALLATION REQUIREMENTS. 12.ROOF MOUNTED EQUIPMENT SHALL BE LABELED AS TO THE SPACE IT SERVES. 13.AT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL, OR OTHER ACCEPTABLE METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH MAY ENTER THE SYSTEM. 14.PRIOR TO PERMIT BEING FINALED, A COMPLETE REPORT OF THE COMMISSIONING PROCESS SHALL BE PROVIDED TO THE OWNER OR OWNER'S REPRESENTATIVE AND FORM 5.410 - VERIFICATION SHALL BE COMPLETED AND PROVIDED TO THE INSPECTOR. DRAWINGS ARE BASED ON THE ASSUMPTION THAT THE EXISTING SYSTEM IS FULLY FUNCTIONING. GENERAL CONTRACTOR SHALL COMPLETE DUCT CLEANING, TESTING, AND BALANCE TO CONFIRM THIS ASSUMPTION. IF IT IS DETERMINED THAT ANY PORTION OF SYSTEM IS NOT FUNCTIONING PROPERLY, GENERAL CONTRACTOR SHALL NOTIFY EOR TO PROVIDE SOLUTION. COVER SHEET, DRAWING INDEX R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 EXISTING SPLIT HEAT PUMP SCHEDULE - INDOOR UNIT (FOR REFERENCE ONLY) EQUIP NO.SERVICE NOMINAL CAPACITY, TONS MOUNTING/ DISCHARGE FAN ELECTRICAL SOUND POWER, dBA WEIGHT, LBS BASIS OF DESIGN CONNECTED OUTDOOR UNITAIRFLOW, CFM MOTOR DRIVE VOLTAGE MCA MOCP (E)FC-1 BOH 5 HORIZONTAL 2000 DIRECT 208-230V/1P (1)(1)--TRANE 2TEC3F60 (E)CU-1 (E)FC-2 LOBBY/STAFF RM 5 HORIZONTAL 2000 DIRECT 208-230V/1P (1)(1)--TRANE 2TEC3F60 (E)CU-3 (E)FC-3 LOBBY/CONF RM 5 HORIZONTAL 2000 DIRECT 208-230V/1P (1)(1)--TRANE GAM5B0C60 (E)CU-2 (E)FC-4 ATM RM 3 HORIZONTAL 1200 DIRECT 208-230V/1P (1)(1)--CARRIER FX4DNF037 (E)CU-4 NOTES:(1)INDOOR UNIT IS POWERED FROM OUTDOOR UNIT. EXISTING SPLIT HEAT PUMP SCHEDULE - OUTDOOR UNIT (FOR REFERENCE ONLY) EQUIP NO.SERVICE NOMINAL CAPACITY, TONS TOTAL COOLING CAPACITY, BTUH TOTAL HEATING CAPACITY, BTUH ELECTRICAL SOUND POWER, dBA WEIGHT, LBS BASIS OF DESIGN CONNECTED INDOOR UNITVOLTAGEMCAMOCP (E)CU-1 BOH 5 60,000 60,000 208-230V/3P 25 40 --TRANE 2TWA0060A3000AB (E)FC-1 (E)CU-2 LOBBY/CONFERENCE RM 5 60,000 60,000 208-230V/3P 21 35 --TRANE 4TWA4060A3000AA (E)FC-3 (E)CU-3 LOBBY/STAFF RM 5 60,000 60,000 208-230V/3P 25 40 --TRANE 2TWA0060A3000AB (E)FC-2 (E)CU-4 ATM RM 3 36,000 -208-230V/1P 17 30 --CARRIER 24APB636A0030010 (E)FC-4 DIFFUSER SCHEDULE TAG DESCRIPTION AIRFLOW, CFM NC AT MAX CFM FACE SIZE, IN NECK, IN MOUNTING BASIS OF DESIGN CD-1 CEILING DIFFUSER 0 - 700 30 24X24 (1)ACT GRID TITUS MCD RG-1 CEILING GRILLE 0 - 800 30 24X24 (1)ACT GRID TITUS PAR EG-1 CEILING GRILLE 0 - 800 30 24X24 (1)ACT GRID TITUS PAR TG-1 CEILING GRILLE 0 - 800 30 24X24 (1)ACT GRID TITUS PAR NOTES:(1)NECK SIZE VARIES. SEE M200 FOR SIZES AND QUANTITIES. NEW SPLIT AIR CONDITIONER SCHEDULE - INDOOR UNIT EQUIP NO.SERVICE NOMINAL CAPACITY, TONS MOUNTING/ DISCHARGE FAN ELECTRICAL SOUND POWER, dBA WEIGHT, LBS BASIS OF DESIGN CONNECTED OUTDOOR UNITAIRFLOW, CFM MOTOR DRIVE VOLTAGE MCA MOCP (N)FC-5 ATM/LAN RM 1.5 WALL 754 DIRECT 208-230V/1P (1)(1)49 31 DAIKIN FTK18BXVJU (N)CU-5 NOTES:(1)INDOOR UNIT IS POWERED FROM OUTDOOR UNIT. (2)PROVIDE EXTERNAL CONDENSATE PUMP - LITTLEGIANT MODEL #VCCA-2OULS OR EQUAL. NEW SPLIT AIR CONDITIONER SCHEDULE - OUTDOOR UNIT EQUIP NO.SERVICE NOMINAL CAPACITY, TONS TOTAL COOLING CAPACITY, BTUH SEER2/EER2 ELECTRICAL SOUND POWER, dBA WEIGHT, LBS BASIS OF DESIGN CONNECTED INDOOR UNITVOLTAGEMCAMOCP (N)CU-5 ATM/LAN RM 1.5 18,000 20/12.5 208-230V/3P 13 20 54 95 DAIKIN RK18BXVJU (N)FC-5 NEW FAN SCHEDULE EQUIP NO.SERVICE MOUNTING/ DISCHARGE AIRFLOW, CFM ESP. IN WG ELECTRICAL OPERATION WEIGHT, LBS BASIS OF DESIGN (1)(2) VOLTAGE HP(W) (N)EF-1 JANITOR'S CLOSET CEILING 100 0.5 115V / 1P 0.01(22)WALL SWITCH 16 GREENHECK SP-LP0511-1 (N)BEF-1 UNIVERSAL RR CEILING 100 0.5 115V / 1P 0.01(22)(3)16 GREENHECK SP-LP0511-1 (N)BEF-2 RR CEILING 100 0.5 115V / 1P 0.01(22)(3)16 GREENHECK SP-LP0511-1 NOTES:(1)PROVIDE BACKDRAFT DAMPERS ON EXHAUST FANS. (2)VIBRATION ISOLATION: FANS < 150 LBS RUBBER ISOLATORS, FANS > 150 LBS SPRING ISOLATORS (3)PROVIDE OCCUPANCY SENSOR. FAN TO RAMP UP TO FULL SPEED UPON DETECTION OF OCCUPANT. PROVIDE A 15-MINUTE DELAY BEFORE SHUTTING DOWN. SCHEDULES & DETAILS SAMPLE DETAIL SCALE: NONE 6 M001 DETAIL SCALE: NONE 2 M001 EXTERNAL CONDENSATE PUMP IN HIGH WALL BACK VIEW HIGH WALL FAN COIL UNIT. BOD: MITSUBISHI/TRANE NV SERIES ELECTRICAL ACCESS OPENING VENT TUBE UNIT CONDENSATE DRAIN LINE RESERVOIR. POWER AND CONTROL WIRING TO HIGH WALL POC FOR CONDENSATE LINE. SEE PLUMBING DRAWING FOR CONDENSATE LINE ROUTING. CONDENSATE PUMP. BOD: RECTORSEAL MINI AQUA UNIVOLT NOTE: 1.BOD: RECTORSEAL MINI AQUA UNIVOLT. FOLLOW OTHER CONDENSATE PUMP MANUFACTURE'S INSTRUCTION FOR INSTALLATION REQUIREMENT. CLEAR SPACE FOR INSTALLATION RECTANGULAR DUCT SUPPORT 45 ° ± 1 5 ° 45° ± 15° IF SEISMIC RESTRAIN IS REQUIRED, STRUCTURAL DETAIL SUPERSEDE MECHANICAL DETAIL. STEEL ANGLE SELF-TAPPING SHEET METAL SCREWS VIBRATION ISOLATOR IF REQUIRED PER ACOUSTIC THREADED ROD RECTANGULAR DUCT PER PLAN NOTE:FRONT VIEW PLAN VIEW ANCHOR PER STRUCTURAL ROUND DUCT SUPPORT 45 ° ± 1 5 ° 45° ± 15° IF SEISMIC RESTRAIN IS REQUIRED, STRUCTURAL DETAIL SUPERSEDE MECHANICAL DETAIL. SELF-TAPPING SHEET METAL SCREWS VIBRATION ISOLATOR IF REQUIRED PER ACOUSTIC THREADED ROD ROUND DUCT PER PLAN NOTE:FRONT VIEW PLAN VIEW ANCHOR PER STRUCTURAL SHEET METAL STRAP SAMPLE DETAIL SCALE: NONE 5 M001 DETAIL CEILING DIFFUSER SEE ARCH. PLANS FOR CEILING CONST. VOLUME DAMPER DUCT PER MECHANICAL PLAN FLEXIBLE DUCT CONNECTION ANCHOR TO STRUCTURE DUCT SUPPORT CEILING DIFFUSER MOUNTING & CONNECTION 3 M001 SUPPLY OUTLET RETURN AIR CEILING MOUNTED MECHANCIAL UNIT MOUNTING DETAIL PLAN VIEWSIDE VIEW THREADED ROD IF SEISMIC RESTRAIN IS REQUIRED, STRUCTURAL DETAIL SUPERSEDE MECHANICAL DETAIL. ANCHOR PER STRUCTURAL NOTE: 4 M001 NEW SPLIT HEAT PUMP SCHEDULE - INDOOR UNIT EQUIP NO.SERVICE NOMINAL CAPACITY, TONS MOUNTING/ DISCHARGE ECONOMIZER Y/N FAN ELECTRICAL SOUND POWER, dBA WEIGHT, LBS BASIS OF DESIGN CONNECTED OUTDOOR UNITAIRFLOW, CFM MOTOR DRIVE VOLTAGE MCA MOCP (N)FC-1 BOH 5 INLINE N 2000 DIRECT 208-230V/1P 10 15 43 170 TRANE GAM5B0C60 (N)CU-1 (N)FC-2 LOBBY/STAFF ROOM 5 INLINE N 2000 DIRECT 208-230V/1P 10 15 43 170 TRANE GAM5B0C60 (N)CU-3 NOTES:(1)PROVIDE ELECTRICAL DISCONNECT SWITCH AND INDIVIDUAL THERMOSTAT FOR EACH UNIT. (2)NEW UNIT TO REPLACE EXISTING (NOT SHOWN). RECONNECT EXISTING DUCTWORK AND CONDENSATE LINE. UPDATE POWER CONNECTION SIZING. (3)ECONOMIZER EXCEPTION: SERVING DEDICATED SERVER ROOM, EQUIPMENT EFF. +15% BETTER THAN CODE (C403.5 EXCEPTION 11). NEW SPLIT HEAT PUMP SCHEDULE - OUTDOOR UNIT EQUIP NO.SERVICE NOMINAL CAPACITY, TONS RATED COOLING CAPACITY, BTUH SEER2 RATED HEATING CAPACITY, BTUH COP ELECTRICAL SOUND POWER, dBA WEIGHT, LBS BASIS OF DESIGN CONNECTED INDOOR UNITVOLTAGEMCAMOCP (N)CU-1 BOH 5 57982 14.5 52500 3.5 208-230V/3P 21 35 50 248 TRANE 4TWA4060A3000A (N)FC-1 (N)CU-3 LOBBY/STAFF ROOM 5 57982 14.5 52500 3.5 208-230V/3P 21 35 50 248 TRANE 4TWA4060A3000A (N)FC-2 NOTES:(1)ARI LISTED WITH ALL STANDARD FEATURES, INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING PROTECTION. FILTER DRIER, REFRIGERANT LINE FILTER, LIQUID SOLENOID VALVE, AND SAFETY PRESSURE SWITCHES. INSTALL REFRIGERANT TUBING IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SECURE UNIT TO PAD USING STAINLESS STEEL SCREWS. TYPICAL FOR (6) LEGS REFRIGERANT LINES INSULATED TYPICAL CU ONE LAYER OF ROOFING MEMBRANE PLASTIC 2" HIGH TOTALINE PAD DETAIL SCALE: NONE 1 M001 CONDENSER MOUNTING SCHEDULES & DETAILS R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 0'4'8'N MECHANICAL DEMO PLAN SCALE: 1/4" = 1'-0" GENERAL NOTES 1.ALL MECHANICAL SYSTEMS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED ON PLANS. SEE M200 FOR APPROXIMATE DUCTWORK SIZING. 2.DISTRIBUTION LINES AND SIZES SHOWN EXISTING ARE APPROXIMATE AND SHALL BE CONFIRMED BY MECHANICAL CONTRACTOR PRIOR TO MODIFICATION. KEY NOTES 1.DEMO EXISTING DIFFUSER/GRILLE AND DUCTWORK AS SHOWN. SEE M200 FOR NEW LAYOUT. 2.DEMO EXISTING DIFFUSERS/GRILLES AND ASSOCIATED DUCTWORK UP TO MAIN TRUNK. 3.DEMO DIFFUSERS/GRILLES AND ASSOCIATED DUCTWORK. FAN COIL TO REMAIN FOR FUTURE TENANT USE. IF REQUIRED, SHIFT UNIT INTO LAN ROOM CEILING SPACE TO AVOID INTERFERENCE WITH NEW FULL HEIGHT PARTITION. 4.DEMO EXISTING BATHROOM EXHAUST FAN AND ASSOCIATED DUCTWORK. BUILDING LOBBY (NIC) ELEVATOR (NIC) ELECTRICAL ROOM (NIC) CORRIDOR (NIC) (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)RG-1 (E)RG-1 (E)RG-1(E)RG-1 (E)RG-1 (E)RG-1 (E)RG-1 (E)RG-1 (E)RG-1 (E)CD-1 (E)EG-2 10Ø 12Ø (E)EF (E)FC-1(E)FC-2(E)FC-3 (E)FC-4 2 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 (E)BEF (E)BEF 1 1 1 4 4 2 MECHANICAL DEMO PLAN R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 GENERAL NOTES 1.ALL MECHANICAL SYSTEMS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED ON PLANS. 2.CONTRACTOR TO CONFIRM EXISTING DUCTWORK LOCATIONS AND SIZING. 3.PROVIDE FLOAT SWITCH IN DRAIN PAN OF NEW MECHANICAL UNITS THAT WILL SHUT DOWN THE EQUIPMENT IN THE EVENT THE PRIMARY DRAIN IS BLOCKED, PER CMC 310.2 OPTION 1. KEY NOTES 1.POINT OF CONNECTION TO EXISTING DUCTWORK. 2.NEW WALL MOUNTED FAN COIL. ROUTE CONDENSATE TO NEAREST APPROVED RECEPTACLE. SEE PLUMBING DRAWINGS FOR PROPOSED ROUTING. 3.CONTRACTOR TO COORDINATE REFRIGERANT PATHWAY IN FIELD WITH LANDLORD AND TENANT ABOVE. 4.EXISTING FAN COIL TO REMAIN IN SPACE FOR FUTURE USE. RELOCATE AS NECESSARY TO AVOID CONFLICT WITH NEW FULL HEIGHT WALL. 5.REWORK DUCTWORK AS NECESSARY TO ACCOMMODATE NEW DIFFUSER/GRILLE LOCATION. 6.EXISTING EXHAUST LOUVER TO REMAIN. 7.PROVIDE NEW DUCTWORK TO TERMINATE AT EXISTING LOUVER ON EXTERIOR. 0'4'8'N HVAC PLAN SCALE: 1/4" = 1'-0" 1 106 CMR.3 105 ATM / LAN ROOM 104 WORK ROOM 100 COMMON VESTIBULE 101 BANKING HALL 107 RRB 108 CMR.4 109 MEETING ROOM 110 STAFF ROOM 112 CORRIDOR 115 JANITOR CLOSET 113 RESTROOM 114 UNIVERSAL RR 116 CORRIDOR 119 COUPON BOOTH 120 BM 121 AB 122 EMPLOYEE ENCLAVE 123 CMR.2 124 CMR.1 A-401 1 117 EXISTING SD VAULT 1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)CD-1 (E)RG-1 (E)RG-1 (E)RG-1(E)RG-1 (E)RG-1 (E)RG-1 (E)RG-1 (E)RG-1 (E)CD-1 (E)EG-2 (E)EF (N)FC-2 (E)FC-3 (E)FC-4 10Ø 12Ø CD-1 300 CD-1 250 CD-1 250 CD-1 250 CD-1 250 CD-1 300 CD-1 250 CD-1 250 CD-1 350 CD-1 200 CD-1 200 CD-1 250 CD-1 100 CD-1 150 CD-1 300 CD-1 600 CD-1 400 CD-1 350 CD-1 350 CD-1 350 CD-1 350 RG-1 400 RG-1 RG-1 RG-1 RG-1 RG-1 RG-1 (N)FC-5 1 RG-1 900 EG-1 TG-1 TG-1 TG-1 TG-1 TG-1 TG-1 TG-1 10 Ø 10Ø 12 Ø 12Ø 10Ø 10 Ø 12 Ø 10Ø 10Ø 10Ø 18 Ø 18Ø 8Ø 8Ø8Ø 10Ø 8Ø 12Ø 8Ø 12Ø 8Ø 14 Ø 14Ø 10Ø 12Ø 16Ø 16 Ø 16Ø 1 8 Ø 18 Ø 1 1 1 1 1 1 1 1 1 1 1 1 1 1 TG-1 TG-1 TG-1 TG-1 TG-1 TG-1 TG-1 10 Ø 10Ø 10 Ø 10Ø 10Ø 14Ø 2 12 Ø 12Ø 12Ø 18 Ø 10Ø 10Ø 10Ø 16 Ø 10Ø10 Ø 10 Ø 14 Ø 12Ø 16 Ø 10Ø 14 Ø 12 Ø 3 4 5 5 18 Ø 5 8Ø 8Ø 5Ø 5Ø 8Ø 8Ø 10Ø 5Ø 1 6 6 (N)EF-1 (N)BEF-1 (N)BEF-2 FC-57 7 RT 12 Ø 10 Ø 12 Ø (N)FC-1 1 EXISTING OUTSIDE AIR INTAKE 1 HVAC PLAN R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 (N)CU-1(E)CU-2(N)CU-1 (E)CU-4 (E)RTU (E)RTU (E)RTU (E)RTU (E)RTU (E)EF (E)EF (N)CU-5 GENERAL NOTES 1.ALL MECHANICAL SYSTEMS ARE EXISTING TO REMAIN UNLESS OTHERWISE NOTED ON PLANS. KEY NOTES 1.NEW ROOFTOP CONDENSING UNIT. ROUTE REFRIGERANT TO (N)FC-5 AT LEVEL 1 UTILIZING SAME CHASE AS (E)CU-5. CONTRACTOR TO CONFIRM ROUTING. 2.DISCONNECT POWER TO EXISTING UNIT. UNIT TO REMAIN FOR FUTURE USE. 3.UNITS WITHIN DASHED LINE ASSOCIATED WITH TENANT SPACE IN SCOPE. ALL OTHER UNITS NOTED ARE OUTSIDE SCOPE OF WORK. 4.DEMO EXISTING CONDENSER AND REPLACE WITH NEW. 0'4'8'N ROOF PLAN SCALE: 1/4" = 1'-0" 1 2 EXISTING ROOF HATCH 3 3 44 ROOF PLAN R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 GENERAL NOTES 1.ALL WIRELESS ADAPTERS MUST BE PROVIDED WITH UNINTERRUPTED/UNSWITCH POWER. 2.INSTALLER MUST BECOME FAMILIAR WITH THE PUBLISHED INSTALLATION GUIDES FOR THE PRODUCTS IN THE PROJECT SCOPE. REFER TO INTELLICOMMAND INSTALLATION GUIDELINES. 3.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROCUREMENT AND INSTALL OF INTELLICOMMAND AND RELATED COMPONENTS PERTAINING TO HVAC. 4.MOUNT ALL THERMOSTATS 44" ABOVE FINISHED FLOOR. 5.THE INTELLICOMMAND SYSTEM WILL INCLUDE COMMUNICATION INTERFACE IN ORDER TO NETWORK FACILITY TO COMPANY WIDE SYSTEM NETWORK. 6.INTELLICOMMAND MANUFACTURER TO PROVIDE ENGINEERING AND APPROVE CONTROL PLAN BEFORE INSTALLATION. KEY NOTES 1.PROVIDE TEMPERATURE SENSOR MOUNTED IN SUPPLY DUCT. 2.REPLACE EXISTING THERMOSTAT WITH NEW. RELOCATE TO POSITION SHOWN ON PLANS. CONFIRM LOCATION WITH ARCHITECTURE PRIOR TO INSTALLATION. 0'4'8'N MECHANICAL CONTROL PLAN SCALE: 1/4" = 1'-0" INTELLICOMMAN DEVICES KEY: MODEM BMS WIRED DUCT TEMP. SENSOR. MODEL TDDDR00DUCT BMS WIRELESS THERMOSTAT/ROOM CONTROLLER: THERMOSTAT ADAPTER MAY BE REQUIRED. VERIFY WITH UNIT MANUFACTURER. MODEL VT8600 T ZONE BMS MODEM. PROVIDE POWER AND LINK WITH ROOM CONTROLLERS. TELTONICA MODEL RUT950W02400 BMS WIRELESS CO2 TEMPERATURE AND HUMIDITY SENSOR. MOUNT ON CEILING PANEL NEAR RETURN AIR TERMINAL. PAIR WITH NEAREST ROOM CONTROLLER. MODEL SED-CO2-G-5045 CO2 FC-3 T 2 T FC-2 FC-1 T 2 2 CO2 MODEM DUCT (N)FC-2 (E)FC-3 (N)FC-1 DUCT DUCT 1 1 1 MECHANICAL CONTROL PLAN R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 ROBISON ENGINEERING 19401 40TH AVE. W. SUITE 302 LYNNWOOD, WA 98036 206-364-3343 09/12/2024 ROBISON ENGINEERING 19401 40TH AVE. W. SUITE 302 LYNNWOOD, WA 98036 206-364-3343 09/12/2024 JACOB O'BRIEN M-39197 SHAUN NEUBAUER TITLE 24 R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 EQUIPMENT SPECIFICATIONS R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 EQUIPMENT SPECIFICATIONS R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 ABBREVIATIONSGENERAL NOTES PRE-CONSTRUCTION MEETING NOTES SYMBOLS ABV ABOVE AD AREA DRAIN AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION BFF BELOW FINISHED FLOOR BFP BACKFLOW PREVENTER BOH BACK OF HOUSE BP BOOSTER PUMP BT BATHTUB BTUH BRITISH THERMAL UNIT PER HOUR BV BALANCING VALVE C COMMON CAP CAPACITY CB CATCH BASIN CD CONDENSATE DRAIN CFF CAPPED FOR FUTURE CFM CUBIC FEET PER MINUTE CI CAST IRON CLG CEILING, COOLING CLW CLOTHES WASHER CO CLEANOUTS COMB COMBUSTION CONT CONTINUE, CONTROL CONTR CONTRACTOR COTG CLEANOUTS TO GRADE CP CIRCULATING PUMP CV CHECK VALVE CW COLD WATER D DIAMETER DB DRY BULB, DECIBEL DF DRINKING FOUNTAIN DFU DRAIN FIXTURE UNITS DI DUCTILE IRON DIM DIMENSION DN DOWN DS DOWN SPOUT DWG DRAWING (E)EXISTING EFF EFFICIENCY ELEC ELECTRIC EQUIV EQUIVALENT EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXT EXTERIOR, EXTERNAL F FAHRENHEIT FCO FLOOR CLEANOUTS FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FF FINISHED FLOOR FLR FLOOR FPM FEET PER MINUTE FPS FEET PER SECOND FS FLOOR SINK FT FEET FU FIXTURE UNITS G GAS (LOW PRESSURE) GAL GALLONS GD GARAGE DRAIN GM GAS METER GPG GRAINS PER GALLON GPM GALLONS PER MINUTE GV GATE VALVE GWB GYPSUM WALLBOARD GWH GAS WATER HEATER HB HOSE BIBB HD HEAD HDR HUB DRAIN HEDV HOSE END DRAIN VALVE HORIZ HORIZONTAL HP HORSEPOWER HPCW HIGH PRESSURE COLD WATER HW HOT WATER HWC HOT WATER RE-CIRCULATION HWCP HOT WATER CIRCULATION PUMP HWR HOT WATER RETURN HWST HOT WATER STORAGE TANK HX HEAT EXCHANGER ICW INDUSTRIAL COLD WATER ID INDIRECT DRAIN, INSIDE DIAMETER IE INVERT ELEVATION IHW INDUSTRIAL HOT WATER IN INCH KS KITCHEN SINK KW KILOWATT L LONG, LENGTH LAV LAVATORY LB POUND M WATER METER MBH THOUSAND BTU PER HOUR MECH MECHANICAL MCA MIN. CIRCUIT AMPACITY MOCP MAX. OVER CURRENT PROTECTION MPG MEDIUM PRESSURE GAS MTD MOUNTED (N)NEW NC NORMALLY CLOSED NO NORMALLY OPEN OD OUTSIDE DIMENSION/DIAMETER OVERFLOW DRAIN/DECK DRAIN OPD OVER PRESSURE DEVICE OPNG OPENING P PUMP PD PRESSURE DROP, PLANTER DRAIN POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PRESSURE RELIEF VALVE PS PUMPED STORM DRAINAGE PSIG POUNDS PER SQUARE INCH GAUGE PSD PUMPED STORM DRAINAGE PSS PUMPED SANITARY SEWER PSW PUMPED SANITARY WASTE PW PUMPED WASTE RD ROOF DRAIN REF REFERENCE RPBP REDUCED PRESSURE BACKFLOW PREVENTER RPM REVOLUTIONS PER MINUTE S SINK SCH SCHEDULE SCW SOFTENED COLD WATER SD STORM DRAIN SEP SEWAGE EJECTOR PUMP SF SQUARE FOOT SGSV SEISMIC GAS SHUT-OFF VALVE SH SHOWER SO STORM OVERFLOW SP STATIC PRESSURE/SUMP PUMP SR SUDS RELIEF SS STAINLESS STEEL/SANITARY SEWER SSS SIDE SANITARY SEWER STD STANDARD SQ SQUARE TD TRENCH DRAIN TMV THERMOSTATIC MIXING VALVE TP TRAP PRIMER TYP TYPICAL UH UNIT HEATER UON UNLESS OTHERWISE NOTED UR URINAL V VENT VTR VENT THRU ROOF W WASTE, WATT, WIDE WC WATER CLOSET WCO WALL CLEANOUTS WHD WALL HYDRANT WM WASHING MACHINE WSFU WATER SUPPLY FIXTURE UNITS THE FOLLOWING TRADES SHALL BE REPRESENTED FOR THE MINIMUM TIME INDICATED: MECHANICAL SHEET METAL 4 HOURS PLUMBING/PIPING 4 HOURS ELECTRICAL 4 HOURS SPRINKLER 2 HOURS GENERAL CONTRACTOR ALL SESSIONS CONTRACTORS SHALL ATTEND A PRE-CONSTRUCTION MEETING WITH THE ENGINEER FOR THE PURPOSE OF REVIEWING THE WORK PRIOR TO ORDERING ANY EQUIPMENT OR PERFORMING ANY WORK. THE MEETING SHALL BE LOCATED AT THE PROJECT SITE ON A DATE AND TIME TO BE MUTUALLY AGREED. THE MEETING WILL BE A WORKING SESSION. THE MEETING WILL BE FACILITATED BY THE ENGINEER AND THE AGENDA WILL INCLUDE A DETAILED REVIEW OF THE PLANS AND SPECIFICATIONS, CROSS CHECK WITH OTHER TRADES FOR COORDINATION ISSUES, REVIEW OF PROPOSED PRODUCTS, REVIEW OF PLANNED MEANS AND METHODS,AND ON-SITE INVESTIGATION OF FIELD CONDITIONS RELATIVE TO EXISTING CONDITIONS THAT COULD AFFECT THE WORK. PERSONS ATTENDING THE MEETING SHALL BE KNOWLEDGEABLE OF THE PROJECT AND SHALL BE THE SPECIFIC PERSONS INTENDED TO CONTINUE WITH THE PROJECT THROUGH TO COMPLETION. IF REQUIRED, REVISED PLANS WILL BE ISSUED THROUGH OFFICIAL CHANNELS. CHANGES IN THE BID PRICE WILL BE DISCUSSED, BUT NO CHANGE ORDERS WILL BE ISSUED UNLESS PROCESSED THOUGH OFFICIAL CHANNELS. IT SHALL BE UNDERSTOOD THAT THE ENGINEER HAS NO AUTHORITY TO ISSUE CHANGE ORDERS. PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS FOR REVIEW AND APPROVAL PRIOR TO ORDERING MATERIAL OR DOING WORK. FOR EQUIPMENT THAT IS SCHEDULED BY MANUFACTURER'S NAME AND CATALOG DESIGNATIONS, THE MANUFACTURER'S PUBLISHED DATA AND/OR SPECIFICATION FOR THAT ITEM ARE CONSIDERED PART OF SPECIFICATION. ENGINEERING COSTS FOR REVISING MEP PLANS SHALL BE ADDRESSED IN THE COST ANALYSIS OF THE SUBSTITUTION PROPOSAL. CONTRACTOR TO COORDINATE WITH ENGINEER AND DETERMINE ASSOCIATED DESIGN AND PERMITTING COSTS. CONTRACTOR SHALL BE RESPONSIBLE FOR OTHER COSTS ASSOCIATED WITH UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS OR REVISIONS. CONTRACTOR SUBSTITUTIONS & REVISIONS APPLICABLE CODES 1.REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE WORK COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL, CIVIL, ELECTRICAL, LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY). 2.ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC. OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED. 3.CODES: COMPLETE INSTALLATION OF THE PLUMBING SYSTEM SHALL BE PER THE APPLICABLE BUILDING, MECHANICAL, ENERGY, PLUMBING, FIRE, AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. 4.PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL STRUCTURAL SHOP DRAWINGS FOR LOCATING AND ROUTING ALL EQUIPMENT, PIPING, ETC. A.COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL. B.COORDINATE FINAL LOCATION AND ROUTING WITH CEILING, LIGHTS, WALLS, FIRE SPRINKLER PIPING, AND OTHER TRADES WORK. C.INCLUDE ADDITIONAL OFFSETS, ELBOWS, ROUTING, EQUIVALENT DUCT SIZING EXCHANGE, RELOCATING, ETC. AS REQUIRED FOR A COMPLETE OPERATING MECHANICAL SYSTEM. D.PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. 5.PLUMBING CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL PLUMBING EQUIPMENT WITHIN THE STRUCTURE. 6.ACCESS DOORS: COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. VERIFY ACCESS DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO BIDDING. 7.ROOF PENETRATIONS: SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP, ROOF CURB, ROOF DRAIN, OVERFLOW DRAINS AND VTR DETAILS. 8.EXPOSED PIPING: PROVIDE CHROME PLATING FOR EXPOSED PIPING IN FINISHED ROOMS. 9.PENETRATIONS: PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK PENETRATIONS. 10.SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND PENETRATIONS IN AIR PLENUMS. 11.LIGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND REPLACEMENT. 12.CABLE TRAYS: PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" ABOVE AND TO THE SIDE OF CABLE TRAYS. 13.MOTORS: COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM EFFICIENCIES UNDER FULL LOAD. 14.ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. COORDINATION REQUIREMENTS 1.IRRIGATION SYSTEM: COORDINATE IRRIGATION WATER DEMAND, MINIMUM WATER PRESSURE REQUIREMENTS & CONTROL CABINET LOCATIONS WITH IRRIGATION CONTRACTOR. 2.GAS: CONTRACTOR/GAS COMPANY SHALL FINALIZE GAS METER AND GAS SERVICE LOCATIONS. INSTALL SEISMIC GAS SHUT OFF VALVE PER GAS COMPANY REGULATIONS. 3.UTILITIES: COORDINATE WITH SITE UTILITY CONTRACTOR AND CIVIL DRAWINGS FOR UTILITY CONNECTIONS AND EXTENSIONS. 4.ROOF DRAINAGE: COORDINATE WITH GENERAL CONTRACTOR FOR ROOF DRAIN AND OVERFLOWS, SCUPPER DRAINS, AND CONDENSATE DRAINS. 5.PLUMBING FIXTURES & EQUIPMENT: COORDINATE EXACT LOCATION OF ALL PLUMBING FIXTURES & EQUIPMENT WITH ARCHITECTURAL AND OTHER TRADES DOCUMENTS. 6.PIPING: COORDINATE EXACT LOCATION OF ALL STRUCTURAL FRAMING & FOOTINGS AND FINALIZE THE EXACT ROUTING OF ALL PIPES WITH STRUCTURAL ENGINEER AT THE SITE PRIOR TO AND DURING THE CONSTRUCTION. COORDINATE UNDER GRADE PIPING & FOUNDATION DRAINAGE PIPING WITH CIVIL ENGINEER. 7.ADJUSTMENTS: ALL EQUIPMENT, MOTORS, FANS GAS BURNERS, IGNITION DEVICES, DRIVES, ETC. SHALL BE ADJUSTED AND BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL. 8.APPROVALS: MECHANICAL AND PLUMBING EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, APPLICABLE CODES AND REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THE BID DOCUMENTS. 9.FIRE PROTECTION: CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PROTECTION SPRINKLER SYSTEM IN COMPLIANCE WITH NFPA AND LOCAL CODES. PROVIDE DESIGN, PERMITS, MATERIALS, INSTALLATION, TESTING AND ALL OTHER FOR A FULLY OPERATIONAL SYSTEM. LOCATION OF ALL PIPING TO BE COORDINATED WITH OTHER TRADES. 10.PRIOR TO PIPING INSTALLATION: PLUMBING CONTRACTOR TO COORDINATE PIPING LAYOUT WITH ALL OTHER TRADES. 11.ACCESS: COORDINATE ALL ACCESS LOCATIONS WITH GENERAL CONTRACTOR AND ARCHITECT TO ENSURE ALL REQUIRED ACCESS HATCHES, ACCESS PANELS & ACCESS COVERS ARE PROVIDED. 12.PROVIDE WATER TIGHT SEALS FOR ANY PIPING PENETRATING THE EXTERIOR FOUNDATION WALLS OR SLABS. 13.ANY DISCREPANCIES SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. 14.PROVIDE FIRE PROOFING FOR ALL PIPING PENETRATING FIRE BARRIER WALLS OR FLOOR SLABS. GENERAL EXISTING WORK TO BE REMOVED MATCHLINE OR PROPERTY LINE EQUIPMENT TYPICAL EQUIPMENT DESIGNATION PIPING WASTE ABOVE GRADE VENT STORM DRAIN OVERFLOW STORM DRAIN CONDENSATE DRAIN COLD WATER (CW) HOT WATER (HW), POTABLE, 120°F PIPE PLUG UNION WYE STRAINER FUEL OIL SUPPLY FUEL OIL RETURN FUEL OIL VENT RELIEF VENT LOW PRESSURE NATURAL GAS WYE STRAINER WITH CAPPED HOSE END BLOWDOWN VALVE BALL VALVE GLOBE VALVE CHECK VALVE BALANCING OR PLUG VALVE PRESSURE REDUCING VALVE (PRV) AUTOMATIC CONTROL VALVE, 2-WAY AUTOMATIC CONTROL VALVE, 3-WAY RELIEF VALVE BALANCING/METERING VALVE PRESSURE GAUGE THERMOMETER PIPE ANCHOR PIPE ALIGNMENT GUIDE PIPE SUPPORT VALVE STATION OR ASSEMBLY PUMP INDIRECT DRAIN, PIPE TO DRAIN A P-3 P-3 HWCP-1 SD OD CD FOR FOV RV G FOS ID P/T A PS BUTTERFLY VALVE PUMPED WASTEPW 140 140 ID FLOOR DRAIN HOSE BIBB IRR IRRIGATION (NON POTABLE) FLANGE BALL VALVE BREAK IN PIPING OR DUCTWORK RPBP DOUBLE CHECK VALVE ASSEMBLY DCVA FOF FUEL OIL FILL INDICATES DIRECTION OF CUTTING LETTER INDICATES SECTION (NO. INDICATES DETAIL) SHEET NUMBER WHERE SECTION IS DRAWN SHEET NUMBER WHERE SECTION IS TAKEN W FLEXIBLE CONNECTION IN PIPING PRV HOT WATER CIRCULATING, POTABLE, TEMPERATURE OTHER THAN 120°F HOT WATER CIRCULATING (HWC), POTABLE, 120°F HOT WATER, POTABLE, TEMPERATURE OTHER THAN 120°F SS IW INDIRECT WASTE SANITARY SEWER ABOVE GRADE V SS SANITARY SEWER BELOW GRADE CONNECTION TO EXISTING EXISTING PIPING (THIN LINE) NEW PIPING (HEAVY LINE) ARCHITECTURAL BACKGROUND (THIN LINE) SECTION IDENTIFICATION MEDIUM PRESSURE NATURAL GASMPG ROOF DRAIN, OVERFLOW DRAIN PRESSURE/TEMPERATURE TEST PORT REDUCED PRESSURE BACKFLOW PREVENTER REDUCER DIRECTION OF FLOW INLINE WATER METERM POINT OF CONNECTION CATCH BASIN - SAND/OIL INTERCEPTOR TRENCH DRAIN SEISMIC GAS SHUT-OFF VALVE WASHER BOX GREASE INTERCEPTOR # # DETAIL IDENTIFICATION DETAIL NUMBER DRAWING/SHEET NUMBER ODRD EMERGENCY GAS SHUT-OFF VALVE WASTE BELOW GRADEW GAS METERGM PIPE CAP PIPE TURNING DOWN/DROP PIPE TURNING UP BOTTOM PIPE CONNECTION TOP PIPE CONNECTION PIPE SYMBOLS PSS PUMPED SANITARY SEWER PSD PUMPED STORM DRAIN PCD PUMPED CONDENSATE DRAIN F FIRE MAIN BV THE FOLLOWING PROJECT DESIGN IS BASED ON THE FOLLOWING CODES: -2022 CALIFORNIA BUILDING CODE (CBC) -2022 CALIFORNIA MECHANICAL CODE (CMC) -2022 CALIFORNIA PLUMBING CODE (CPC) -2022 CALIFORNIA ELECTRICAL CODE (CEC) -2022 CALIFORNIA ENERGY CODE 1.CONNECTIONS: PROVIDE PLUMBING FIXTURE CONNECTIONS TO BUILDING WASTE, VENT, COLD WATER, AND HOT WATER SYSTEM IN ACCORDANCE WITH DRAWINGS, MANUFACTURER'S RECOMMENDATIONS, AND LOCAL CODES. CONNECT TO EACH FIXTURE, EQUIPMENT, ETC. WITH ALL ACCESSORIES, VALVES, VACUUM BREAKERS, REGULATORS, UNIONS, ETC. AS REQUIRED AND AS RECOMMENDED BY THE MANUFACTURERS. REFER TO PLUMBING FIXTURE CONNECTION SCHEDULE ON PLANS. 2.HOT AND COLD: WATER PIPING CONNECTION TO EACH FIXTURE SHALL BE COLD WATER ON THE RIGHT HAND SIDE AND HOT WATER ON THE LEFT HAND SIDE. 3.HOT WATER: NON-CIRCULATING HOT WATER PIPE SHALL NOT EXCEED 10' UNLESS OTHERWISE SHOWN ON DRAWINGS. 4.VENT STACKS: COORDINATE VENT STACK WITH HVAC EQUIPMENT TO MAINTAIN MINIMUM 10' CLEARANCE FROM OUTSIDE AIR INTAKES. 5.CLEANOUTS: PROVIDE CLEANOUTS PER CURRENT CPC AND AS REQUIRED BY LOCAL JURISDICTIONS. CLEANOUTS SHALL BE LOCATED IN WALLS/FLOORS WHERE THEY ARE NOT HIGHLY VISIBLE. FLOOR CLEANOUTS IN CARPETED AREAS TO BE FITTED WITH CARPET INSERTS. LOCATIONS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL. NOTE: NOT ALL CLEANOUTS ARE SHOWN ON THE PLUMBING DRAWINGS. 6.SUDS RELIEF: PROVIDE SUDS RELIEF IN ACCORDANCE WITH 2015 CPC SECTION 711.0, STATE AND LOCAL CODES. 7.SHUT-OFFS: PROVIDE 1/4 TURN BALL VALVE ANGLE STOP SHUT-OFF VALVES AND BRAIDED STAINLESS STEEL FLEX CONNECTORS AT HOT AND COLD WATER SUPPLY TO EACH FIXTURE. EXCEPTION: PROVIDE SCREWDRIVER STOPS AT BATH/SHOWERS. 8.TUB SPOUTS SHALL BE THREADED (NO PUSH-ON FITTINGS). 9.TRAP ARMS: PROVIDE TRAP ARMS SUCH THAT THE MAXIMUM LENGTH WILL NOT EXCEED CODE REQUIREMENTS. 10.ADA INSULATION: AT PLUMBING PIPING EXPOSED UNDER LAVATORIES, INSULATE THE EXPOSED PIPING AND TRAPS WITH PRODUCT SPECIFICALLY DESIGNED FOR THIS APPLICATION MEETING ADA REQUIREMENTS. PROVIDE HANDI-LAV GUARD OR EQUIVALENT. OFFSET P-TRAPS TO CLEAR WHEELCHAIR ACCESS. 11.GAS EQUIPMENT: GAS EQUIPMENT SHALL BE INSTALLED PER EQUIPMENT LISTINGS, APPLICABLE IFGC, UPC, LOCAL CODES & NFPA STANDARDS. 12.GAS CONNECTIONS: INSTALL FLEXIBLE QUICK DISCONNECT ASSEMBLIES FOR ALL GAS FIRED KITCHEN EQUIPMENT PER APPLICABLE IFGC, UPC, LOCAL CODES & NFPA STANDARDS. PROVIDE LOCKABLE GAS SHUT-OFF VALVES FOR FIREPLACES & BBQS IN UNATTENDED PUBLIC LOCATIONS IN THE BUILDING. 13.GAS PIPING CONNECTIONS TO WATER HEATERS, BOILERS AND FURNACES SHALL HAVE DIRT LEGS AND UNIONS PROVIDED ON APPLIANCE SIDE OF SHUTOFF VALVE. 14.GAS PIPING INSTALLATION: STEEL OR MALLEABLE IRON FUEL LINES 2" OR SMALLER SHALL BE ASSEMBLED USING THREAD SEALANT SUITABLE FOR NATURAL GAS. GAS PIPING LARGER THAN 2" SHALL HAVE WELDED FITTINGS. 15.GAS PIPING UNDERGROUND: WHERE INSTALLED BELOW GRADE THROUGH THE OUTER FOUNDATION OR BASEMENT WALL OF A BUILDING, SHALL BE ENCASED IN A PROTECTIVE PIPE SLEEVE. THE ANNULAR SPACE BETWEEN THE GAS PIPING AND THE SLEEVE SHALL BE SEALED. 16.GAS PIPING ABOVE GROUND: WHERE PASSING THROUGH AN OUTSIDE WALL, GAS PIPING SHALL BE PROTECTED AGAINST CORROSION BY COATING OR WRAPPING WITH AN INERT MATERIAL. WHERE PIPING IS ENCASED IN A PROTECTIVE PIPE SLEEVE, THE ANNULAR SPACE BETWEEN THE PIPING AND THE SLEEVE SHALL BE SEALED. 17.GAS PIPE SUPPORT: FUEL LINES SHALL BE SUPPORTED OR STRAPPED, AND SHALL BE PLUMB AND SQUARE. 18.GAS PIPING ON ROOFTOPS SHALL BE SUPPORTED AND ANCHORED TO THE ROOF. 19.GAS PIPING SHALL NOT BE BURIED UNDER A BUILDING, SLAB OR OTHER STRUCTURE. 20.GAS PIPING PROTECTIVE COATING: PAINT ALL EXTERIOR EXPOSED GAS PIPING WITH TWO COATS OF RUST INHIBITIVE PAINT. COLOR: GRAY. 21.WATER HAMMER ARRESTORS: PROVIDE AT THE END OF HOT AND COLD WATER LINES SERVING TWO OR MORE FIXTURES; SIZE IN ACCORDANCE WITH PLUMBING AND DRAINAGE INSTITUTE (PDI) REQUIREMENTS. WATER HAMMER ARRESTORS ARE REQUIRED FOR QUICK CLOSING VALVES, SUCH AS LAUNDRY WASHERS, FLUSH VALVES (PUBLIC TOILETS), ETC. 22.TRAP PRIMERS AS SPECIFIED: PROVIDE TRAP PRIMERS AND PIPING FOR FLOOR DRAINS, FLOOR SINKS, AREA DRAINS & HUB DRAINS. ARRANGE PIPING TO ACHIEVE EQUAL FLOW TO EACH DRAIN AND FLOOR SINK FOR TRAP PRIMERS SERVING MULTIPLE DRAINS AND FLOOR SINKS. COORDINATE EXACT LOCATIONS WITH ARCHITECT & ELECTRICAL ENGINEER. 23.P-TRAPS: ALL EXPOSED P-TRAPS SHALL BE CHROME-PLATED BRASS. P-TRAPS SERVING HANDICAPPED COUNTER TOP LAVATORIES SHALL BE INSULATED. 24.THROUGHOUT THE PROJECT PROVIDE BALL VALVES. GATE VALVES SHALL NOT BE USED. NO EXCEPTIONS. 25.HOT WATER RECIRCULATING BALANCING VALVES SHOULD BE BELL & GOSSETT CIRCUIT SETTER (WATTS OR EQUAL) WITH INTEGRAL READOUT PORTS, ADJUSTMENT KNOB, DRAIN CONNECTION, AND POSITIVE SHUTOFF. 26.DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. 27.REDUCERS: PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION SIZES. 28.VALVE TAGS: PROVIDE VALVE TAGS PER SPECIFICATIONS TO IDENTIFY VALVE AND THE AREA IT SERVES. 29.OFFSETS: PROVIDE FOR BRANCH LINES TO EQUIPMENT. 30.ALL TEMPERATURE MIXING VALVES SHALL COMPLY WITH ASSE-1070 SAFETY STANDARDS. 31.PROVIDE PIPE MARKER WITH DIRECTION OF FLOW. LABEL "NON-POTABLE WATER DO NOT DRINK" CLEARLY ON NON-POTABLE WATER PIPING. 32.PROVIDE EXPANSION LOOPS/EXPANSION JOINTS IN PIPING PER 2022 CPC TABLE 313.3 AND MANUFACTURER INSTALLATION INSTRUCTIONS. 33.PROVIDE APPROVED PIPE HANGERS & PIPE SUPPORTS IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND 2022 CPC TABLES 313.3 & 313.6. SUBMIT FOR APPROVAL. 34.DIELECTRIC UNIONS: PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. 35.REFRIGERANT PIPING: PROVIDE SIZING & INSTALLATION IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 36.CONDENSATE DRAIN: PROVIDE A P-TRAP FOR EACH HVAC UNIT CONDENSATE PAN WITH PLUG TEES FOR CLEANING. CONDENSATE DRAINS SHALL BE DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. 37.PIPING & EQUIPMENT SUPPORTS/HANGERS & SEISMIC RESTRAINTS TO BE DESIGNED BY DESIGN BUILT CONTRACTOR. 38.IF NEEDED, PROVIDE VACUUM BREAKERS AT ALL HOSE BIBBS. 39.FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE AND SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR WATER SEALS IN ACCORDANCE WITH 2022 CPC 1007.0. 40.INSULATION MATERIAL SHALL MEET CITY OF ARCADIA QUALITY STANDARDS. 41.ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE 2022 CALIFORNIA STATE ENERGY CODE. 42.BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH 2022 CPC 701.0 AND 903.0. 43.ALL SANITARY SYSTEM MATERIAL SHALL BE LISTED BY AN APPROVED LISTING AGENCY. 44.ALL STORAGE WATER HEATING EQUIPMENT SHALL BE PROVIDED WITH AN APPROVED, LISTED EXPANSION TANK OR OTHER DEVICE DESIGNED FOR INTERMITTENT OPERATION FOR THERMAL EXPANSION CONTROL PER 2022 CPC 608.3. 45.WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL DISPLACEMENTS DUE TO SEISMIC MOTION PER 2022 CPC 507.2. 46.MATERIAL EXPOSED WITHIN A DUCT OR PLENUM SHALL COMPLY WITH 2022 CMC 602.2.1. 47.HVAC EQUIPMENT AND WATER HEATERS SHALL COMPLY WITH 2022 CMC CHAPTER 3. 48.BOILERS SHALL COMPLY WITH ALL THE REQUIREMENTS OF 2022 CMC CHAPTER 10. 49.PROVIDE EXPANSION TANKS FOR BOILERS PER 2022 CMC SECTION 1009.0. 50.SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE PROVIDED WITH MIXING VALVES PER 2022 CPC 408.0. 51.PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH CITY OF ARCADIA WATER CONSERVATION STANDARDS. 52.CONTRACTOR SHALL PROVIDE FIRESTOPPING AT PENETRATIONS AS NECESSARY TO RETAIN THE FIRE RATING OF ALL ASSEMBLIES. ALL WORK SHALL BE IN COMPLIANCE WITH CODE REQUIREMENTS FOR THE BUILDING CONSTRUCTION TYPE. 53.ALL GARAGE DRAINS, TRASH ROOMS DRAINS & GARAGE TRENCH DRAINS SHALL BE TAKEN TO SAND/OIL INTERCEPTOR(S) BEFORE CONNECTING TO THE SANITARY SEWER SYSTEM. 54.PLUMBING CONTRACTOR SHALL PROVIDE REDUCED PRESSURE BACKFLOW PREVENTERS OR OTHER APPROVED BACKFLOW PREVENTION DEVICE WHERE REQUIRED BY HEALTH AUTHORITIES, FOOD SERVICE DRAWINGS, APPLIANCE MANUFACTURER INSTRUCTIONS AND BY CODE. PROVIDE REQUIRED & PROPER BACK FLOW PREVENTERS AS SPECIFIED FOR THE APPLIANCES INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: PLUMBING NOTES DRAWING INDEX DRAWING INDEX SHEET DESCRIPTION P000 GENERAL NOTES & DRAWING INDEX P001 FIXTURE SCHEDULE & DETAILS P100 PLUMBING PLAN GENERAL NOTES & DRAWING INDEX R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 1 WATER HEATER DETAIL P-001 2 WATER HEATER PLATFORM DETAIL P-001 WATER HEATER STAND SHALL BE HOLDRITE MODEL 50-SWHP-WM. INSTALL PER MANUFACTURERS RECOMMENDATIONS NOTE: BOTTOM OF WATER HEATER PLATFORM SHALL BE AT MINIMUM OF 6'-6" ABOVE FINISHED FLOOR (MAXIMUM OF 10'-0" A.F.F.). VERIFY EXACT LOCATION WITH ARCHITECT. FASTEN SECURELY TO WALL PER MANUFACTURERS RECOMMENDATIONS. ELECTRIC WATER HEATER PROVIDE DRAIN PAN AND EXTEND OVERFLOW DISCHARGE TO SERVICE SINK. 34" HOT WATER SCALE: N.T.S SCALE: N.T.S BALL VALVE (TYP) HEAT TRAP CIRCULATING PUMP THERMOMETER VACUUM RELIEF VALVE MINIMUM 6" ABOVE WATER HEATER - WATTS OR EQUAL TEMPERATURE AND PRESSURE RELIEF VALVE DISCHARGE RELIEF VALVE LINE FULL SIZE TO MOP SINK BELOW 1" DRAIN FROM PAN TO FLOOR DRAIN. DRAIN PAN WITH 2" LIP INSTALL ON STEEL PLATFORM PROVIDE CAP ON DRAIN VALVE DRAIN VALVE DIELECTRIC UNION (TYP) 34" COLD WATER INLET EXPANSION TANK 3 4" COLD WATER BALANCING VALVE SET TO 0.5 GPM CHECK VALVE (TYP) HEAT TRAP 12" HOT WATER RETURN AQUASTAT NOTES: 1.SET TANK AS CLOSE TO WALL AS POSSIBLE AND PROVIDE WOOD BLOCK SPACERS AS REQUIRED. 2.SET WATER HEATER TEMPERATURE TO 120°F. PLUMBING EQUIPMENT SCHEDULE PLAN MARK SERVICE SIZE (LOAD) FLOW RATE FIXTURE TYPE FINISH BASIS OF DESIGN NOTES (1)(2)(3)(4)CW (WSFU) HW (WSFU) W (DFU) V (DFU) G (MBH) PLUMBING EQUIPMENT WH-1 3 4"3 4"----ELECTRIC WATER HEATER -AO SMITH DEL-30 30 GAL, 19 GPH @ 100°F, 4.5kW. SEE NOTES 5 & 6. ET-1 3 4"-----EXPANSION TANK -AMTROL ST-5 PRECHARGE TO MEASURED STATIC PRESSURE AT POINT OF INSTALLATION. PLUMBING FIXTURES WC-4 3/4" (2.5)-3" (3) 2" (3)-1.6 GPF FLUSH VALVE WATER CLOSET -REFER TO PLUMBING FIXTURE SCHEDULE ON ARCHITECTURAL SHEET A-606 - L-1/L-2 1/2" (0.75) 1/2" (0.75) 2" (1) 1 1/2" (1)-0.5 GPM LAVATORY -REFER TO PLUMBING FIXTURE SCHEDULE ON ARCHITECTURAL SHEET A-606 - S-1/S-2 1/2" (1.125) 1/2" (1.125) 2" (2) 1 1/2" (2)-1.5 GPM SINK -REFER TO PLUMBING FIXTURE SCHEDULE ON ARCHITECTURAL SHEET A-606 - MS-1 1/2" (2.25) 1/2" (2.25) 2" (3) 1 1/2" (3)--MOP SINK -REFER TO PLUMBING FIXTURE SCHEDULE ON ARCHITECTURAL SHEET A-606 PROVIDE WITH MOP SINK FAUCET (MS-2). S-5 1/2" (0.5)-1 12" (0.5) 1 1/2" (0.5)--DRINKING FOUNTAIN -REFER TO PLUMBING FIXTURE SCHEDULE ON ARCHITECTURAL SHEET A-606 - S-7 1/2" (0.5)-1 1/2" (0.5) 1 1/2" (0.5)--WATER REFILL STATION -REFER TO PLUMBING FIXTURE SCHEDULE ON ARCHITECTURAL SHEET A-606 - NOTES:(1)REFER TO ARCHITECTURAL PLANS FOR MOUNTING HEIGHT. (2)CONTRACTOR SHALL CONFIRM MAKE, MODEL, AND FINISH OF ALL FIXTURES WITH OWNER PRIOR TO ORDERING. (3)PROVIDE 14 TURN ANGLE STOPS WITH BRAIDED STAINLESS STEEL FLEX CONNECTORS AT HOT AND COLD WATER SUPPLY TO EACH FIXTURE. (4)PROVIDE ASSE-1070 MIXING VALVES SET TO 100°F AND METERING FAUCETS AT ALL PUBLIC-USE LAVATORIES. (5)PROVIDE WITH WALL MOUNTING PLATFORM (WHP), SEE ARCHITECTURAL SHEET A-504 AND A-606. (6)DISCONNECT SWITCH PROVIDED BY MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR. FIXTURE SCHEDULE & DETAILS R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 PLUMBING PLAN SCALE: 1/4" = 1'-0" 0'2'4'8' 109 MEETING ROOM 110 STAFF ROOM 112 CORRIDOR 113 RESTROOM 114 UNIVERSAL RR 115 JANITOR CLOSET 117 EXISTING SD VAULT 119 COUPON BOOTH 116 CORRIDOR 120 BM 121 AB 122 EMPLOYEE ENCLAVE 124 CMR.1 123 CMR.2 100 COMMON VESTIBULE 104 WORK ROOM 105 ATM / LAN ROOM 106 CMR.3 107 RRB 108 CMR.4 101 BANKING HALL 118 VAULT STORAGE 111 COAT CLOSET 4'- 0 " 13 ' - 1 0 1 / 4 " 9" 4 1 / 2 " 9" 8" 8' - 1 1 " 7 1/2" 5'- 7 " 9" 4 1 / 2 " 9" 4'-6"6" 6"5'-7" 8' - 5 1 / 2 " 1 S-1 GENERAL NOTES 1.THERMOSTATIC MIXING VALVE: VERIFY IF THERMOSTATIC IS PROVIDED FOR LAVATORIES. IF NONE ARE EXISTING , PROVIDE ASSE 1070 MIXING VALVE SET TO 110°F. 2.REMOVE ALL UNUSED PLUMBING SUPPLY, WASTE AND VENT PIPES. DO NOT ABANDON IN CEILING, WALLS OR FLOOR. 3.CONTRACTOR SHALL LOCATED AND INSPECT SHUT-OFF VALVES TO ENSURE PROPER WORKING ORDER AND ACCESSIBLE LOCATION. MARK-UP LOCATIONS ON AS-BUILTS. KEY NOTES 1.NEW WATER HEATER TO BE LOCATED ABOVE MOP SINK. SEE DETAIL 1/P001 AND DETAIL 2/P001. 2.REMOVE EXISTING PLUMBING FIXTURES AND CONNECTIONS. TEMPORARILY CAP PLUMBING FOR FUTURE INSTALLATION OF NEW OR REUSED FIXTURES. 3.PROVIDE WATER CLOSET. RECONNECT EXISTING 3 4"CW, 3"W, AND 2"V TO LAVATORY. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS, LOCATIONS, AND ADA REQUIREMENTS. MODIFY PLUMBING AS NECESSARY TO ACCOMMODATE REMODEL. 4.PROVIDE SINK. RECONNECT EXISTING 12"CW,12"HW, 2"W, 112"V TO SINK. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS, LOCATIONS, AND ADA REQUIREMENTS. MODIFY PLUMBING AS NECESSARY TO ACCOMMODATE REMODEL. 5.PROVIDE MOP SINK. RECONNECT EXISTING 12"CW, 12"HW, 2"W, 112"V TO SINK. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS, LOCATIONS, AND ADA REQUIREMENTS. MODIFY PLUMBING AS NECESSARY TO ACCOMMODATE REMODEL. 6.PROVIDE LAVATORY. RECONNECT EXISTING 12"CW, 12"HW, 2"W, 112"V TO SINK. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS, LOCATIONS, AND ADA REQUIREMENTS. MODIFY PLUMBING AS NECESSARY TO ACCOMMODATE REMODEL. 7.RUN 12"CW LINE FROM EXISTING CW LINE TO NEW FIXTURE. 8.RUN 112"W AND 112"V FROM FIXTURE TO EXISTING WASTE AND VENT SYSTEM. 9.LAVATORY FIXTURE TO BE SAVED AND REUSED. 10.PROVIDE CONDENSATE PUMP FOR FC-5. MODEL LITTLE GIANT VCCA-20ULS 11.ROUTE 34"CD LINE TO MOP SINK. DRAIN INDIRECTLY. 12.CONNECT NEW 2"SS LINE FROM S-5 AND S-7 TO EXISTING SS LINE. CONTRACTOR TO CONFIRM LOCATION AND ROUTING IN FIELD. 13.EXISTING FAN COIL TO BE REPLACED WITH NEW UNIT. RECONNECT NEW UNIT TO EXISTING CONDENSATE ROUTING. CONTRACTOR TO VERIFY CONDENSATE PIPING IS CORRECTLY ROUTED AND INDIRECTLY DRAINED TO SERVICE SINK. MS-1 WH-1 WC-4 L-1 WC-4 S-5 6 2 4 5 7 3 3 2 2 812"CW 112"V UP 112"W DN 12"CW 112"V UP 112"W DN 7 8 S-7 92 2 2 MS-2 L-2 S-2 (N)FC-5 10 11 12 2"W (N)FC-1 (N)FC-2 13 13 R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT DR 2024/07/19 O E O No. M-39197 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN EE R ER J . CAJ 'BRIE FOETATS A L I F O R NIA N A N I C AHCEM L B 10/28/24 ISSUED FOR CLIENT REVIEW 2024/09/06 ISSUED FOR PERMIT AND BID 2024/09/13 DR DR SS SS SS PLAN CHECK #2 2024/10/28DRSS1 PLUMBING PLAN CONTRACTORS SHALL ATTEND A PRE-CONSTRUCTION MEETING WITH THE ENGINEER FOR THE PURPOSE OF REVIEWING THE WORK PRIOR TO ORDERING ANY EQUIPMENT OR PERFORMING ANY WORK. THE MEETING SHALL BE LOCATED AT THE PROJECT SITE ON A DATE AND TIME TO BE MUTUALLY AGREED. THE MEETING WILL BE A WORKING SESSION. THE MEETING WILL BE FACILITATED BY THE ENGINEER AND THE AGENDA WILL INCLUDE A DETAILED REVIEW OF THE PLANS AND SPECIFICATIONS, CROSS CHECK WITH OTHER TRADES FOR COORDINATION ISSUES, REVIEW OF PROPOSED PRODUCTS, REVIEW OF PLANNED MEANS AND METHODS,AND ON-SITE INVESTIGATION OF FIELD CONDITIONS RELATIVE TO EXISTING CONDITIONS THAT COULD AFFECT THE WORK. PERSONS ATTENDING THE MEETING SHALL BE KNOWLEDGEABLE OF THE PROJECT AND SHALL BE THE SPECIFIC PERSONS INTENDED TO CONTINUE WITH THE PROJECT THROUGH TO COMPLETION. IF REQUIRED, REVISED PLANS WILL BE ISSUED THROUGH OFFICIAL CHANNELS. CHANGES IN THE BID PRICE WILL BE DISCUSSED, BUT NO CHANGE ORDERS WILL BE ISSUED UNLESS PROCESSED THOUGH OFFICIAL CHANNELS. IT SHALL BE UNDERSTOOD THAT THE ENGINEER HAS NO AUTHORITY TO ISSUE CHANGE ORDERS. PRE-CON MEETING NOTES SYMBOLS ABBREVIATIONS M MAU-1,5HP,480,3 T WP EF-1,12KVA,208,1 POWER SIGNAL/COMMUNICATION MISCELLANEOUS J +42" RECEPTACLES SD Sa SOS SWITCHES A 2-32 LIGHTING 1 SYMBOL NAME DETAIL IDENTIFICATION GENERAL S OS S AL S DT ST S2 GFCI TV L10 GFCI CONTROLLED AND NON CONTROLLED DUPLEX RECEPTACLE (SPLIT WIRED RECEPTACLE)a DUPLEX RECEPTACLE, WITH HEIGHT ABOVE FINISHED FLOOR INDICATED CEILING MOUNTED DUPLEX RECEPTACLE CONNECTION FOR LIGHTED MIRROR COORDINATE LOCATION AND ELEVATION WITH ARCHITECT PRIOR TO ROUGH-IN L T THERMOSTAT 1.DRAWINGS ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. 2.THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. 3.REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. 4.REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. 5.PROVIDE CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. LIGHT LINE INDICATES NON-ELECTRICAL OR BACKGROUND (THIS IS NOT CONTRACTUAL DEFINITION OF WORK) HEAVY LINE INDICATES NEW WORK (THIS IS NOT CONTRACTUAL DEFINITION OF WORK) FLAG NOTE REVISION NOTE REVISION DEFINITION, AREA ENCIRCLED CONTAINS DRAWING CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE FIXTURE IDENTIFICATION SYMBOL (TYPE A, (2) 32 WATT LAMPS SHOWN) SEE SCHEDULE SEE LUMINAIRE SCHEDULE FOR FIXTURE SYMBOLS SWITCH, SINGLE POLE; WITH SWITCHING SUBSCRIPT OCCUPANCY SENSOR SWITCH, PROXIMITY INFRARED SWITCH, SINGLE POLE; WITH SWITCHING SUBSCRIPT "D" INDICATES WALLBOX DIMMER CEILING MOUNTED OCCUPANCY SENSOR CEILING MOUNTED AMBIENT LIGHT SENSOR WALL MOUNTED DUAL TECHNOLOGY OCCUPANT SENSOR SWITCH, TIMER. SWITCH, TWO POLE. SINGLE RECEPTACLE DUPLEX RECEPTACLE: WALL MOUNTED, +18" AFF DUPLEX RECEPTACLE - ABOVE COUNTER DUPLEX GFCI ABOVE COUNTER DUPLEX GFCI DOUBLE DUPLEX RECEPTACLE: WALL MOUNTED, +18" AFF FLOOR BOX ONE DUPLEX RECEPTACLE FLOOR BOX ONE DUPLEX RECEPTACLE + ONE DATA FLOOR BOX ONE DUPLEX RECEPTACLE + ONE DATA + ONE VOICE SPECIAL PURPOSE RECEPTACLE, AS NOTED JUNCTION BOX: 4SQ MOUNTED JUNCTION BOX: 4SQ WALL MOUNTED JUNCTION BOX: 4SQ TRACK DATA OUTLET: WALL MOUNTED @ +18" AFF U.O.N. TELEPHONE/DATA OUTLET: WALL MOUNTED @ +18" AFF U.O.N. TELEVISION OUTLET: WALL MOUNTED @ +18" AFF U.O.N. PANELBOARD NON-FUSED DISCONNECT SWITCH (WP = NEMA 3R WHERE APPROPRIATE ) FUSED DISCONNECT SWITCH MOTOR CONNECTION (EQUIPMENT NAME, HORSEPOWER, VOLTAGE, AND PHASE INDICATED) EQUIPMENT CONNECTION (EQUIPMENT NAME, LOAD, VOLTAGE, AND PHASE INDICATED) TRANSFORMER, DRY TYPE, SHOWN TO SCALE KW METER AND BASE A AMPERE AC ALTERNATING CURRENT, ABOVE COUNTER AFF ABOVE FINISHED FLOOR AIC AMPS INTERRUPTING CAPACITY AL ALUMINUM AMP AMPERE AWG AMERICAN WIRE GAUGE BKR BREAKER BLDG BUILDING C COIL or CONDUIT CKT CIRCUIT CO CONDUIT/RACEWAY ONLY CT CURRENT TRANSFORMER Cu COPPER CW COOL WHITE D DIMMER DED DEDICATED EC ELECTRICAL CONTRACTOR EF EXHAUST FAN ELEC ELECTRICAL EMT ELECTRICAL METALLIC TUBING EQUIP EQUIPMENT EXIST EXISTING FAA FIRE ALARM ANNUNCIATOR FACP FIRE ALARM CONTROL PANEL FLUOR FLUORESCENT GC GENERAL CONRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND GRS GALVANIZED RIGID STEEL HID HIGH INTENSITY DISCHARGE HP HORSEPOWER IG ISOLATED GROUND KCMIL THOUSAND CIRCULAR MILLS KVA KILOVOLT AMPERES KW KILOWATT LTG LIGHTING LV LOW VOLTAGE MFR MANUFACTURER MIN MINIMUM MLO MAIN LUGS ONLY N NEUTRAL NEC NATIONAL ELECTRICAL CODE (NFPA-70) NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NTS NOT TO SCALE PNL PANEL POC POINT OF CONNECTION PT POTENTIAL TRANSFORMER PVC POLYVINYL CLORIDE PWR POWER QTY QUANTITY RECEPT RECEPTACLE REF REFERENCE RI ROUGH-IN RM ROOM RO RACEWAY ONLY SHT SHEET SPEC SPECIFICATIONS SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR TYP TYPICAL UG UNDERGROUND UL UNDERWRITERS LABORATORIES UON UNLESS OTHERWISE NOTED V VOLTS W WATTS WW WARM WHITE WP WEATHERPROOF W/WITH W/O WITHOUT XFMR TRANSFORMER XFR TRANSFER Z IMPEDANCE OR ZONE FACP P SD FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR AND SPEAKER. PART OF THE DESIGN/BUILD FIRE ALARM SYSTEM SDCO FIRE ALARM COMBINATION PHOTOELECTRIC SMOKE DETECTOR, CARBON MONOXIDE DETECTOR, AND SPEAKER, GUESTROOM. CARBON MONOXIDE DETECTOR.CO DSD FIRE ALARM SYSTEM CONTROL PANEL FIRE ALARM SYSTEM PULL STATION FIRE ALARM SYSTEM STROBE/SPEAKER ELECTRO-MAGNETIC DOOR HOLDER DUCT SMOKE DETECTOR 1.PLEASE SUBMIT PROPOSALS FOR SUBSTITUTIONS OR REVISIONS FOR REVIEW AND APPROVAL PRIOR TO ORDERING MATERIAL OR DOING WORK. 2.FOR EQUIPMENT THAT IS SCHEDULED BY MANUFACTURER'S NAME AND CATALOG DESIGNATIONS, THE MANUFACTURER'S PUBLISHED DATA AND/OR SPECIFICATION FOR THAT ITEM ARE CONSIDERED PART OF SPECIFICATION. 3.ENGINEERING COSTS FOR REVISING MEP PLANS SHALL BE ADDRESSED IN THE COST ANALYSIS OF THE SUBSTITUTION PROPOSAL. 4.CONTRACTOR TO COORDINATE WITH ENGINEER AND DETERMINE ASSOCIATED DESIGN AND PERMITTING COSTS. CONTRACTOR SHALL BE RESPONSIBLE FOR OTHER COSTS ASSOCIATED WITH UNFORESEEN ISSUES RESULTING FROM SUBSTITUTIONS OR REVISIONS. CONTRACTOR SUBSTITUTIONS & REVISIONS GENERAL 1.PROVIDE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THE GOVERNING ELECTRICAL CODE, LOCAL CODES, ORDINANCES AND REQUIREMENTS OF UTILITY COMPANIES FURNISHING SERVICES TO INSTALLATION. 2.PROVIDE ALL WORK AND ITEMS NECESSARY FOR COMPLETE AND FUNCTIONAL ELECTRICAL SYSTEMS. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW EVERY CONDUIT, BOX, CONDUCTOR OR SIMILAR ITEMS FOR A COMPLETE INSTALLATION. 3.THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND DETERMINE CONDITIONS WHICH MAY AFFECT BID. ANY ITEMS NOT FULLY UNDERSTOOD SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING. 4."REF" INDICATIONS DENOTE WORK COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL, OR MECHANICAL). 5.REFERENCE ARCHITECTURAL DRAWING FOR EXACT LOCATION OF DEVICES. QUESTIONS CONCERNING THE LOCATION OF DEVICES AND EQUIPMENT SHALL BE DIRECTED TO THE ARCHITECT. FAILURE TO COORDINATE REQUIREMENTS SHALL IN NO WAY RESULT IN ADDITIONAL COMPENSATION BEING PROVIDED TO THE CONTRACTOR. 6.WHEREVER THE WORD "PROVIDE" IS USED, IT MEANS, "FURNISH AND INSTALL COMPLETE AND READY FOR USE." 7.COORDINATE LOCATION OF ELECTRICAL WITH OTHER TRADES. 8.REFER TO EQUIPMENT DRAWINGS FOR MECHANICAL CHARACTERISTICS (SIZE, LOCATION, ETC.) OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED. COORDINATE INSTALLATION AND LOCATION OF ALL EQUIPMENT WITH MECHANICAL CONTRACTOR. VERIFY ALL FUSE RATINGS, WIRE SIZES AND DISCONNECT SIZES PRIOR TO INSTALLATION. MATERIALS AND METHODS 1.PROVIDE RACEWAY AND WIRING ROUTED CONCEALED WITHIN BUILDING STRUCTURE WHERE POSSIBLE. WHERE RACEWAY CANNOT BE CONCEALED, IT SHALL BE INSTALLED PER PROJECT MANAGER'S DIRECTION. ALL CONDUIT SHALL BE INSTALLED IN NEAT SYMMETRICAL LINES HORIZONTAL OR PERPENDICULAR TO BUILDING COLUMNS AND ROOF LINES. CONDUITS SHALL BE GROUPED ON COMMON SUPPORTS WHEREVER POSSIBLE. 2.EXPOSED CONDUIT ROUTING: CONDUITS MAY BE ROUTED EXPOSED IN MECHANICAL AND ELECTRICAL ROOMS ONLY. EXPOSED CONDUITS SHALL BE SECURED A MINIMUM OF 6" ABOVE FLOOR. 3.OUTDOOR EXPOSED CONDUIT ROUTING: CONDUITS ROUTED ON ROOF OR EXPOSED TO WEATHER SHALL BE GRC, PVC OR LIQUID-TIGHT FLEX. PROVIDE WATER-TIGHT CONNECTIONS AND FITTINGS. 4.CLEARANCES: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. 5.CONNECTIONS: PROVIDE GRS, METALLIC FLEX, OR LIQUIDTITE FLEX CONDUITS FOR CONNECTIONS TO MOTORS OR MOTORIZED EQUIPMENT. 6.WIRING: PROVIDE MINIMUM #12 AWG WIRE SIZE. IF CONDUIT IS TO BE USED MINIMUM IS TO BE 1/2". FLEXIBLE CONDUIT AND FLEXIBLE CABLE IS PERMISSIBLE THROUGHOUT THE BUILDING. 7.WIRING: PROVIDE MINIMUM #10 AWG COPPER CONDUCTOR SIZE IN 120V BRANCH CIRCUIT RUNS OVER 75' IN LENGTH. SITE ELECTRICAL 1.TRENCHING: COORDINATE ALL TRENCHING WORK WITH OTHER UTILITY LOCATIONS AND DRAINAGE TRENCHES. 2.UNDERGROUND CONDUITS: PROVIDE PVC, SCHEDULE 40, 3/4" MINIMUM. PROVIDE GRC CONDUIT TRANSITION ELBOW WHEN TURNING UP TO ABOVE GRADE. 3.DIRECT-BURIED CONDUITS: CONDUIT FOR BRANCH CIRCUITS OUTSIDE BUILDINGS NOT BENEATH DRIVEWAYS OR PARKING AREAS SHALL BE DIRECTLY BURIED WITHOUT CONCRETE ENCASEMENT. THE DEPTH TO THE TOP OF BURIED CONDUITS SHALL BE 36". PROVIDE MARKER TAPE 12" BELOW GRADE. 4.BELOW SLAB: CONDUIT ROUTED BELOW ON-GRADE FLOOR SLABS SHALL BE INSTALLED PRIOR TO FLOOR SLAB POUR. ROUTE CONDUITS BELOW SLAB AS STRAIGHT AS POSSIBLE TO MINIMIZE BENDS. 5.ALL CONDUITS PENETRATING THE BUILDING ENVELOPE BELOW GRADE SHALL FOLLOW WATERPROOFING REQUIREMENTS IN THE ARCHITECTURAL DRAWINGS. NEUTRALS 1.AT CONTRACTORS OPTION, NEUTRALS MAY BE SHARED ON COMBINED HOMERUNS UNLESS THE CIRCUIT HAS A GFCI BREAKER, AN ISOLATED GROUND, OR IS FROM A PANEL WITH TVSS PROTECTION. ANY NEUTRAL DOWNSTREAM FROM A DIMMER SHALL BE DEDICATED TO THE DIMMED LOAD. 2.NEUTRAL WIRES SHOWN FOR TWO AND THREE POLE MECHANICAL AND KITCHEN EQUIPMENT MAY BE OMITTED UPON VERIFICATION THAT THEY ARE NOT REQUIRED EITHER FOR OPERATION OR CONTROL CIRCUITS PER MANUFACTURER'S SPECIFICATIONS. LIGHTING 1.PROVIDE LIGHT FIXTURES WITH PROPER FITTING FLANGES, MOUNTING SUPPORTS, AND ACCESSORY ITEMS, UL LISTED FOR CONDITIONS OF USE. LOW VOLTAGE LIGHTING 1.PROVIDE LOW VOLTAGE TRANSFORMERS IN NEARBY ACCESSIBLE CEILING SPACE. 2.PROVIDE LOW VOLTAGE CONDUCTORS SIZED PER MANUFACTURER'S GUIDELINES TO MINIMIZE VOLTAGE DROP. LIGHTING CONTROL 1.THE MAXIMUM LIGHTING POWER THAT MAY BE CONTROLLED FROM A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED THAT WHICH IS PROVIDED BY A TWENTY AMPERE CIRCUIT LOADED TO NOT MORE THAN EIGHTY PERCENT. A MASTER CONTROL MAY BE INSTALLED PROVIDED THE INDIVIDUAL SWITCHES RETAIN THEIR CAPABILITY TO FUNCTION INDEPENDENTLY. 2.EMERGENCY FIXTURES: EMERGENCY BATTERY/CHARGER SHALL BE CONNECTED TO AN UNSWITCHED LEG OF THE DESIGNATED CIRCUIT. GENERAL REQUIREMENTS SCOPE SCOPE OF WORK: UPDATE ARCADIA, CA RETAIL SPACE WITH NEW MEP FOR NEW BMO BANK LOCATION. INDEX USB A+C RECEPTACLE INCLUDED IN SET PE R M I T S E T 09 / 1 2 / 2 4 DWG DESCRIPTION E000 LEGEND, GENERAL NOTES, INDEX X E100 LIGHTING PLAN X E200 POWER PLAN - MAIN LEVEL X E201 POWER PLAN - ROOF X E300 ONE LINE DIAGRAM, PANEL SCHEDULES X E400 INTERIOR ENERGY FORMS X E401 EXTERIOR ENERGY FORMS X ES1 SITE LIGHTING X ES2 SITE PHOTOMETRICS X LEGEND, GENERAL NOTES, INDEX E000 E No. E-24894 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN E E R ER FOETA T S A L I F O R N IATRICACELEL M A R K H. STEIN K E R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER 09/12/24 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT MB MHSMB 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT MB MHSISSUED FOR DESIGN DEVELOPMENT 2024-07-23 ISSUED FOR CLIENT REVIEW 2024-09-11 ISSUED FOR PERMIT AND BID 2024-09-12 PLAN CHECK #2 2024-10-281MBMHS MB MHS MB MHS 1 ELECTRICAL ROOM ELEVATOR 18" 2ND LEVEL EGRESS STAIRS 40" GFI 106" 1 LP11A LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1 LA1LA1 LA1LA1 LA1 LA1 LA1 LA1 LA1 LA1 LS2C LS2C LS2C LS2C LP2 LS2C LS2C LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1LD1 LD1LD1 LD1LD1 LD1 LD1LD1 LD1 LD1 LD1 LD1 LD1 LD1 LD1LD1LD1 LD1LD1LD1 LD1 LD1 LD1 LD1 LC1C LC1C LC1C LC1C LS1B LW1 LW1 LC1C LC1C LW1 LW1 LP2 LP2 LW1 LW1 LC1C LC1C LC1C LC1C LW3 LA2 LA2 LA2 LA2 LS1A LP2 LL1 LL1 LC1D LC1C LC1CLC1C LC1C LC1C LC1C LW1 LW1 LP2 LL1 LP2 LW1 LW1 LC3B LC3A LC3B LC3A LP4 LP11B LP11C os os L20 L20 LIGHTING PLAN SCALE: 1/4" = 1'-0"N os os os os os os 1AA-2 LA1 LA1 LC1D LC1D LC1D LC1D LC1D os PR I M A R Y D A Y L I G H T Z O N E SE C O N D A R Y D A Y L I G H T Z O N E L20 L20 LD1 abc a a a b b b ccc c ccc c c ccc c c c de d e f ff os os WAPM C HS WAPM H S C C C C S S S C C 1AA-9 1AA-7 1AA-5 1AA-13 4 E100 A-506 4 E100 A-506 4 E100 A-506 1 ENA_E01C ELECTRICAL SYMBOLS LEGEND DIV\ELECT\GEN\LEGENDS\1605L02G MOTION DETECTOR SWITCH, GROUP "a"Sa LIGHT FIXTURE, CEILING, RECESSED MOUNTED, WALL WASH LIGHT FIXTURE, CEILING, RECESSED MOUNTED, LENSED DUAL HEAD SPOT LIGHT, RECESSED MOUNTED SOFFIT STRIP LIGHT MS UNLESS OTHERWISE NOTEDU.O.N. LIGHT FIXTURE, CEILING, SURFACE MOUNTED SURFACE-MOUNTED COOLER LIGHT S NIGHT LIGHT NL EMERGENCY LIGHTEM OCCUPANCY SENSOROS LIGHTING COMPLIANCE: SET SPEAKERS IN CEILING GRID. DAISY CHAIN THE SPEAKERS (18 GA. OR BETTER SPEAKER WIRE) AT THE FOUR DROP LOCATIONS. SPEAKER WIRE TO RUN THROUGH TRUSSES TO OFFICE RECEIVER LOCATION. GC TO PROVIDE LOW VOLTAGE WIRING TO SPEAKERS. REFER TO TITLE 24 COMPLIANCE FORMS ON SHEETS E05 & E06 CALIFORNIA GREEN BUILDING CODE - NON-RESIDENTIAL A.INTERIOR AND EXTERIOR LIGHTING SHALL BE DESIGNED SUCH THAT ZERO DIRECT-BEAM ILLUMINATION LEAVES THE BUILDING SITE." (5.106.8) B.ALL EXTERIOR LUMINAIRES SHALL BE SHIELDED OR BE CUTOFF LUMINAIRES AS DEFINED IN SECTION 132 (B) OF THE CALIFORNIA ENERGY CODE." (5.106.8) C.INTERIOR LIGHTING SHALL BE CONTAINED WITHIN EACH SOURCE." (5.106.8) D.NO MORE THAN .01 HORIZONTAL FOOTCANDLES SHALL ESCAPE 15 FEET BEYOND THE SITE BOUNDARY." (5.106.8) E.ALL EXTERIOR LIGHTING SHALL HAVE CONTROLS THAT AUTOMATICALLY TURN OFF OR LOWER LIGHT LEVELS DURING INACTIVE PERIODS FROM DUSK TO DAWN." (5.106.8) AUDIO BRANDING SPEAKERS: LIGHT FIXTURE, CEILING, RECESSED MOUNTED, LENSED, W/ 90-MINUTE EMERGENCY BATTERY BACK-UP LIGHT FIXTURE, CEILING, SURFACE MOUNTED, W/ 90-MINUTE EMERGENCY BATTERY BACK-UP MS TOGGLE SWITCH FOR MANUAL ON/OFF LIGHTING CONTROL. CONTROL LEGEND DIMMER SWITCH FOR MANUAL UNIFORM MULTI-LEVEL LIGHTING CONTROL PER 2013 CEC. SWITCH SHALL ALSO HAVE MANUAL ON/OFF FUNCTIONALITY.D SWITCHES LABELED 'OS' SHALL TURN OFF ALL CONNECTED LUMINAIRES WITHIN 30 MINUTES OF SPACE BEING VACANT.D os os PHOTOSENSOR FOR DAYLIGHT ZONE CONTROL SHALL AUTOMATICALLY ADJUSTING THE LIGHT OUTPUT OF ALL CONNECTED LUMINAIRES BASED ON THE DAYLIGHT LEVEL IN THE SPACE. PROVIDE ASSOCIATED POWER PACK. PROVIDE DUAL ZONE PHOTOCELL SENSOR. PS OCCUPANCY SENSOR SHALL TURN OFF ALL CONNECTED LUMINAIRES WITHIN 30 MINUTES OF SPACE BEING VACANT.OS SPEAKER LED 'CLOUD' LIGHT OVER COUNTER AUTOMATIC DAYLIGHTING CONTROLS DAYLIGHT ZONE EXEMPTION 6 TO SECTION 130.1(D): LUMINAIRES IN DAYLIT ZONES IN RETAIL MERCHANDISE SALES AND WHOLESALE SHOWROOM SALES. LIGHTING PLAN E100 E No. E-24894 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN E E R ER FOETA T S A L I F O R N IATRICACELEL M A R K H. STEIN K E R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER 09/12/24 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT MB MHSMB 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT MB MHSISSUED FOR DESIGN DEVELOPMENT 2024-07-23 ISSUED FOR CLIENT REVIEW 2024-09-11 ISSUED FOR PERMIT AND BID 2024-09-12 PLAN CHECK #2 2024-10-281MBMHS MB MHS MB MHS 18 504 1 1 1 LA1 1 ELECTRICAL ROOM ELEVATOR 2ND LEVEL EGRESS STAIRS TYP. TYP. ELECTRICAL ROOM ELEVATOR 18" 2ND LEVEL EGRESS STAIRS 40" GFI 106" 1 (E) +24" J J +38"+38"+38" +38" J +60" +38" +38" +38" +28" J J J J +38" +38" +38" +28" 44" 44" GFCI +24" +38" GFCI +38" GFCI +38" GFCI +42" +42" +18" +34"+34" +34" +34" +40"GFCI +40" GFCI GFCI GFCI +38" GFCI44" +42" +38" +24" 34"34" +24" J 42" +72" 72" 34" 34" 44" 44" +44" +38"+38" 38" 38"+72" 72" 60" 1AA 1A MSB POWER PLAN SCALE: 1/4" = 1'-0"N (E) (E) J +60" +60" +60" J POWERED DOOR GFCI GFCI +30" REFRIG. 1AA-37 1 12 (E) FC-4 0.01KVA,208V3P3W (N) FC-5 0.01KVA,208V3P3W (E) FC-3 0.01KVA,208V3P3W (E) FC-1 0.01KVA,208V3P3W (N) BEF-1 0.02KVA,120V1P2W S (N) BEF-2 0.02KVA,120V1P2W S (N) EF-1 0.02KVA,120V1P2W S (E) FC-2 0.01KVA,208V3P3W 15 15 15 15 9 12 16 (N) WH-1 4.5KVA,208V2P2W AL AL FIRE CONTROL PANEL HU HU HU HU HU HU HU HU HU HU HU XP AV UNDER COUNTER (E) 13 WM SCKP SC SC FLOOR BOX DATA FLOOR BOX DATA FLOOR BOX DATA FLOOR BOX DATA D C DC DC DC ADA PUSH BAR AL FOR MOTORIZED WINDOW SHADES AL SC CONDENSATE PUMP (E) (E) 17 17 1A-7 1A-32 1A-9 1A-51 1A-49 1A-33 1A-27 1A-21 1A-8 1A-47 1A-23 1A-39 (E) 10 (TYP) PULL BOX(E) 4 18 SC 1A-57 1A-10,12 1/2"C,2#10,#10G 17 1A-53 1A-45 1A-19 1A-41 1A-11 1A-35 1A-37 1A-55 1A-25 1A-31 1A-29 1A-17 1A-15 1 1 1 1.PROVIDE AN EMPTY 3/4" FLEXIBLE CONDUIT WILL A PULL LINE FROM CEILING CAVITY DOWN THE DOOR MULLION TO FACILITATE DOOR CONTACT INSTALLATION. 2.CONTRACTOR SHALL PROVIDE ELECTRIC STRIKE TO CONTROL THE RIGHT DOOR ONLY. 3.THE ELECTRICAL CONTRACTOR SHALL PROVIDE A RACEWAY TO THE FRONT OUTER VESTIBULE DOOR FRAMES FOR THE PURPOSE OF RUNNING WIRES FOR THE ELECTRIC DOOR STRIKE, OVERRIDE KEY SWITCH AND ASSOCIATED EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS AND JUNCTION BOXES INCLUDING FLEXIBLE CONDUIT, IF REQUIRED AS WELL AS PULL WIRES AS REQUIRED. 4.FOR EACH ATM PROVIDE A DUPLEX OUTLET AT +18" AFF, A DATA OUTLET MOUNTED AT +18" AFF, AND A SECURITY JUNCTION BOX MOUNTED AT +26" AFF. THE POWER, SECURITY, AND DATA OUTLETS SHALL BE ON THE RIGHT SIDE OF THE ATM (FACING THE ATM FROM THE BACK) FIELD VERIFY CONDITIONS BEFORE ROUGH-IN. THE ATM SECURITY CIRCUIT SHALL BE HARD WIRED BY THE SECURITY VENDOR. SEE AHD AND ATM ELEVATION ON SHEET E2.1. 5.FLAG NOTE NO LONGER USED. 6.RUN POWER/DATA CONDUITS/FEEDERS FROM ABOVE CEILING DOWN THRU WALL IN TRENCH AND UP INTO FLOOR BOX. VERIFY EXACT LOCATION WITH PROJECT MANAGER. 7.J-BOXES, CONDUITS, AND COVER PLATES FOR POWER AND ALARM. ALARM CONDUIT AND BOX TO REMAIN OPEN FOR WIRING BY OWNER'S ALARM CONTRACTOR. 8.RECEPTACLES ARE EXEMPT FROM THE CIRCUIT CONTROLS FOR 120V RECEPTACLES. PRINTERS, COPIERS, IT EQUIPMENT, 24/7 FUNCTION/SECURITY, KITCHEN APPLIANCES PER CEC 8.5. 9.PROVIDE 4-GANG FLUSH FLOOR BOX LEGRAND RFBA4R30. CONTRACTOR TO FURNISH AND INSTALL FLOOR BOX AND ALL OUTLETS, CONNECTORS, ETC. REFER TO ARCH. DRAWINGS FOR EXACT LOCATION. CONTRACTOR SHALL VISIT THE SITE TO OBTAIN EXISTING FLOOR SLAB DEPTH PRIOR TO BID AND FLOOR BOX EQUIPMENT ASSEMBLY RELEASE. FLOOR BOX FINISH SHALL BE COORDINATED DURING FINAL SHOP DRAWING REVIEW. RUN (1) .75"C FOR POWER AND (1) 1.25"C FOR DATA FROM ABOVE CEILING DOWN THRU WALL IN TRENCH. VERIFY EXACT LOCATION WITH BMO MANAGER. 10.PROVIDE APPROPRIATE ROUGH-IN AND FINAL CONNECTION TO MOTORIZED SHADES, FIELD COORDINATE EXACT REQUIREMENTS WITH INSTALLING CONTRACTOR AND ADJUST ACCORDINGLY. CONDUIT FED DOWN FROM ACCESSIBLE CEILING TO BOX MOUNTED IN WINDOW RETURN GYP BOARD WITH A FLEXIBLE GREENFIELD CONDUIT UP TO BOX MOUNTED IN WINDOW FRAME HEADER CONSTRUCTION BELOW BEAM. REFER TO TYPICAL POWER OPERATED WINDOW SHADE ROUGH-IN DETAIL THIS SHEET FOR ADDITIONAL INFORMATION. FIELD COORDINATE OPERATED W/ PROJECT MANAGER AND ARCHITECT AND ADJUST ACCORDINGLY. 11.PROVIDE POWER/DATA STUB UP FROM FLOOR INTO FURNITURE CABINET. ELECTRICAL CONTRACTOR SHALL MAKE CONNECTIONS TO FURNITRE PROVIDED CONDUITS/RACEWAY FOR POWER AND DATA. CONTRACTOR SHALL COORDINATE WITH FURNITURE VENDOR FOR EXACT LOCATION. 12.CONTRACTOR SHALL COORDINATE WITH BMO IT AND AV VENDOR FOR COFERENCE ROOM POWER, DATA, AND AV REQUIREMENTS. REFER TO VENDOR AV DRAWINGS. 13.EXTRON KEYPAD: CONTRACTOR SHALL VERIFY FINAL LOCATION AND ELECTRICAL REQUIREMENTS WITH AV VENDOR DRAWINGS. 14.PROVIDE 4-GANG FLUSH FLOOR BOX LEGRAND RFBA4R30. CONTRACTOR TO FURNISH AND INSTALL FLOOR BOX AND ALL OUTLETS, CONNECTORS, ETC. REFER TO ARCH. DRAWINGS FOR EXACT LOCATION. CONTRACTOR SHALL VISIT THE SITE TO OBTAIN EXISTING FLOOR SLAB DEPTH PRIOR TO BID AND FLOOR BOX EQUIPMENT ASSEMBLY RELEASE. FLOOR BOX FINISH SHALL BE COORDINATED DURING FINAL SHOP DRAWING REVIEW. RUN (1) .75"C FOR POWER AND (1) 1.5"C FOR DATA AND (1) 1.5"C FOR AV TO BACK OF VIDEO. VERIFY EXACT LOCATION WITH BMO MANAGER. 15.FAN COIL UNIT POWERED FROM OUTDOOR UNIT. 16.ELECTRICAL CONTRACTOR TO COORDINATE ALL CIRCUITING FOR EXISTING MECHANICAL UNITS WITH CURRENT CIRCUITS. 17.CONDUIT THROUGH FLOOR SLAB AND STUB UP IN KNEE WALL OF DESK. PROVIDE JUNCTION BOXES AS REQUIRED FOR FURNITURE WHIP AND PROVIDE FINAL CONNECTIONS TO DEVICES AS INDICATED. COORDINATE EXACT LOCATION WITH ARCHITECT AND FURNITURE VENDOR. 18.EXISTING ELECTRICAL INFRASTRUCTURE TO REMAIN FOR NEW TO SCOPE NIGHT DEPOSIT. 19.EXISTING ROOFTOP CONVENIENCE OUTLETS EXISTING TO REMAIN. CIRCUITING TO REMAIN TO BUILDING HOUSE PANEL RATHER THAN TO BMO ARCADIA TI SPACE PANEL. # SHEET GENERAL NOTES 1.CONTRACTOR TO COORDINATE POWER PLAN FIXTURES AND LOCATIONS WITH ARCHITECTURAL ELEVATIONS AND SPECIFICATIONS PER A-105. 2.CONTRACTOR TO COORDINATE WITH LOW VOLTAGE, SECURITY, AND AV DRAWINGS SETS, PER BMO STANDARDS. 3.CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, AND FIELD COORDINATE WITH ARCHITECTURAL AND MEP TEAM FOR SIGNIFICANT DIFFERENCES. 4.CONTRACTOR TO COORDINATE ALL ELECTRICAL INTERCONNECTIONS WITH DIFFERING TRADES REGARDING MECHANICAL UNITS AND LOW VOLTAGE EQUIPMENT WITH INTELLICOMMAND EQUIPMENT. VERIFY WITH NECESSARY PARTIES, INCLUDING LV CONTRACTORS, MECHANICAL CONTRACTORS, AND BMO MANAGER. 5. ALL PUBLIC AREA RECEPTACLES ARE TO BE TAMPERPROOF. FLAG NOTES 1 1 1 TYPICAL POWER OPERATED WINDOW SHADE ROUGH IN DETAIL GYP. BOARD WINDOW JAMB AND WALL FINISH WINDOW STOOL POWERED MECHANICAL ROLLER SHADE ENCLOSURE BY OWNER'S SHADE CONTRACTOR (N.I.C.)- REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS GLAZING SYSTEM SUSPENDED FINISH CEILNG 3/4" RIGID OPEN CONDUIT STUB TO WINDOW OPENING BY ELECTRICAL CONTRACTOR- TERMINATE FLUSH WITH FINISH HEAD- COORD. STUB POSITION WITH MOTORIZED SHADE PRODUCT INFO MOTORIZED SHADE POWER CABLE AND CONNECTIONS BY SHADE CONTRACTOR VERI F Y W I T H V E N D O R VERIFY W I T H V E N D O R VERI F Y W I T H V E N D O R VERIFY W I T H V E N D O R SURFACE-MOUNT JUNCTION BOX WITH TOGGLE SWITCH AT EACH MOTOR CONNECTION. ABOVE CEILNG. CA ENERGY CODE - CONTROLLED RECEPTACLES: 1.PROVIDE CONTROLLED RECEPTACLES IN AREAS INDICATED PER CA ENERGY CODE 130.5(D). 2.WHEN THE AREA IS OCCUPIED, THEN THE CONTROLLED RECEPTACLES SHALL BE ENERGIZED. 3.SPLIT RECEPTACLES TO BE PROVIDED WITH CONTROLLED 120V HOT WIRED TO LOWER OUTLET AND CONTINUOUS 120V HOT WIRED TO UPPER OUTLET. R1 OS CEILING OCCUPANCY SENSOR 3/C #18 CABLE PANEL-X RELAYS TO BE MOUNTED IN ACCESSIBLE LOCATION R2 R3 R4 CIRCUIT NUMBER EXAMPLE PANEL-X PANEL-X PANEL-X 1 POWER PLAN - MAIN E200 E No. E-24894 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN E E R ER FOETA T S A L I F O R N IATRICACELEL M A R K H. STEIN K E R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER 09/12/24 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT MB MHSMB 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT MB MHSISSUED FOR DESIGN DEVELOPMENT 2024-07-23 ISSUED FOR CLIENT REVIEW 2024-09-11 ISSUED FOR PERMIT AND BID 2024-09-12 PLAN CHECK #2 2024-10-281MBMHS MB MHS MB MHS (N) CU-5 3.04KVA,208V3P3W (E) CU-1 5.85KVA,208V3P3W (E) CU-2 4.54KVA,208V3P3W (E) CU-3 5.85KVA,208V3P3W (E)RTU (E)RTU (E)RTU (E)RTU (E)RTU 16 16 16 16 (E)CU-4 1A-26,28,30 1/2"C,3#10,#10G1A-20,22,24 1/2"C,3#10,#10G 1A-14,16,18 1/2"C,3#10,#10G 1A-2,4,6 WP GFCI WP GFCI (E) (E) 1 1 1.PROVIDE AN EMPTY 3/4" FLEXIBLE CONDUIT WILL A PULL LINE FROM CEILING CAVITY DOWN THE DOOR MULLION TO FACILITATE DOOR CONTACT INSTALLATION. 2.CONTRACTOR SHALL PROVIDE ELECTRIC STRIKE TO CONTROL THE RIGHT DOOR ONLY. 3.THE ELECTRICAL CONTRACTOR SHALL PROVIDE A RACEWAY TO THE FRONT OUTER VESTIBULE DOOR FRAMES FOR THE PURPOSE OF RUNNING WIRES FOR THE ELECTRIC DOOR STRIKE, OVERRIDE KEY SWITCH AND ASSOCIATED EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS AND JUNCTION BOXES INCLUDING FLEXIBLE CONDUIT, IF REQUIRED AS WELL AS PULL WIRES AS REQUIRED. 4.FOR EACH ATM PROVIDE A DUPLEX OUTLET AT +18" AFF, A DATA OUTLET MOUNTED AT +18" AFF, AND A SECURITY JUNCTION BOX MOUNTED AT +26" AFF. THE POWER, SECURITY, AND DATA OUTLETS SHALL BE ON THE RIGHT SIDE OF THE ATM (FACING THE ATM FROM THE BACK) FIELD VERIFY CONDITIONS BEFORE ROUGH-IN. THE ATM SECURITY CIRCUIT SHALL BE HARD WIRED BY THE SECURITY VENDOR. SEE AHD AND ATM ELEVATION ON SHEET E2.1. 5.FLAG NOTE NO LONGER USED. 6.RUN POWER/DATA CONDUITS/FEEDERS FROM ABOVE CEILING DOWN THRU WALL IN TRENCH AND UP INTO FLOOR BOX. VERIFY EXACT LOCATION WITH PROJECT MANAGER. 7.J-BOXES, CONDUITS, AND COVER PLATES FOR POWER AND ALARM. ALARM CONDUIT AND BOX TO REMAIN OPEN FOR WIRING BY OWNER'S ALARM CONTRACTOR. 8.RECEPTACLES ARE EXEMPT FROM THE CIRCUIT CONTROLS FOR 120V RECEPTACLES. PRINTERS, COPIERS, IT EQUIPMENT, 24/7 FUNCTION/SECURITY, KITCHEN APPLIANCES PER CEC 8.5. 9.PROVIDE 4-GANG FLUSH FLOOR BOX LEGRAND RFBA4R30. CONTRACTOR TO FURNISH AND INSTALL FLOOR BOX AND ALL OUTLETS, CONNECTORS, ETC. REFER TO ARCH. DRAWINGS FOR EXACT LOCATION. CONTRACTOR SHALL VISIT THE SITE TO OBTAIN EXISTING FLOOR SLAB DEPTH PRIOR TO BID AND FLOOR BOX EQUIPMENT ASSEMBLY RELEASE. FLOOR BOX FINISH SHALL BE COORDINATED DURING FINAL SHOP DRAWING REVIEW. RUN (1) .75"C FOR POWER AND (1) 1.25"C FOR DATA FROM ABOVE CEILING DOWN THRU WALL IN TRENCH. VERIFY EXACT LOCATION WITH BMO MANAGER. 10.PROVIDE APPROPRIATE ROUGH-IN AND FINAL CONNECTION TO MOTORIZED SHADES, FIELD COORDINATE EXACT REQUIREMENTS WITH INSTALLING CONTRACTOR AND ADJUST ACCORDINGLY. CONDUIT FED DOWN FROM ACCESSIBLE CEILING TO BOX MOUNTED IN WINDOW RETURN GYP BOARD WITH A FLEXIBLE GREENFIELD CONDUIT UP TO BOX MOUNTED IN WINDOW FRAME HEADER CONSTRUCTION BELOW BEAM. REFER TO TYPICAL POWER OPERATED WINDOW SHADE ROUGH-IN DETAIL THIS SHEET FOR ADDITIONAL INFORMATION. FIELD COORDINATE OPERATED W/ PROJECT MANAGER AND ARCHITECT AND ADJUST ACCORDINGLY. 11.PROVIDE POWER/DATA STUB UP FROM FLOOR INTO FURNITURE CABINET. ELECTRICAL CONTRACTOR SHALL MAKE CONNECTIONS TO FURNITRE PROVIDED CONDUITS/RACEWAY FOR POWER AND DATA. CONTRACTOR SHALL COORDINATE WITH FURNITURE VENDOR FOR EXACT LOCATION. 12.CONTRACTOR SHALL COORDINATE WITH BMO IT AND AV VENDOR FOR COFERENCE ROOM POWER, DATA, AND AV REQUIREMENTS. REFER TO VENDOR AV DRAWINGS. 13.EXTRON KEYPAD: CONTRACTOR SHALL VERIFY FINAL LOCATION AND ELECTRICAL REQUIREMENTS WITH AV VENDOR DRAWINGS. 14.PROVIDE 4-GANG FLUSH FLOOR BOX LEGRAND RFBA4R30. CONTRACTOR TO FURNISH AND INSTALL FLOOR BOX AND ALL OUTLETS, CONNECTORS, ETC. REFER TO ARCH. DRAWINGS FOR EXACT LOCATION. CONTRACTOR SHALL VISIT THE SITE TO OBTAIN EXISTING FLOOR SLAB DEPTH PRIOR TO BID AND FLOOR BOX EQUIPMENT ASSEMBLY RELEASE. FLOOR BOX FINISH SHALL BE COORDINATED DURING FINAL SHOP DRAWING REVIEW. RUN (1) .75"C FOR POWER AND (1) 1.5"C FOR DATA AND (1) 1.5"C FOR AV TO BACK OF VIDEO. VERIFY EXACT LOCATION WITH BMO MANAGER. 15.FAN COIL UNIT POWERED FROM OUTDOOR UNIT. 16.ELECTRICAL CONTRACTOR TO COORDINATE ALL CIRCUITING FOR EXISTING MECHANICAL UNITS WITH CURRENT CIRCUITS. 17.CONDUIT THROUGH FLOOR SLAB AND STUB UP IN KNEE WALL OF DESK. PROVIDE JUNCTION BOXES AS REQUIRED FOR FURNITURE WHIP AND PROVIDE FINAL CONNECTIONS TO DEVICES AS INDICATED. COORDINATE EXACT LOCATION WITH ARCHITECT AND FURNITURE VENDOR. 18.EXISTING ELECTRICAL INFRASTRUCTURE TO REMAIN FOR NEW TO SCOPE NIGHT DEPOSIT. 19.EXISTING ROOFTOP CONVENIENCE OUTLETS EXISTING TO REMAIN. CIRCUITING TO REMAIN TO BUILDING HOUSE PANEL RATHER THAN TO BMO ARCADIA TI SPACE PANEL. # SHEET GENERAL NOTES 1.CONTRACTOR TO COORDINATE POWER PLAN FIXTURES AND LOCATIONS WITH ARCHITECTURAL ELEVATIONS AND SPECIFICATIONS PER A-105. 2.CONTRACTOR TO COORDINATE WITH LOW VOLTAGE, SECURITY, AND AV DRAWINGS SETS, PER BMO STANDARDS. 3.CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, AND FIELD COORDINATE WITH ARCHITECTURAL AND MEP TEAM FOR SIGNIFICANT DIFFERENCES. 4.CONTRACTOR TO COORDINATE ALL ELECTRICAL INTERCONNECTIONS WITH DIFFERING TRADES REGARDING MECHANICAL UNITS AND LOW VOLTAGE EQUIPMENT WITH INTELLICOMMAND EQUIPMENT. VERIFY WITH NECESSARY PARTIES, INCLUDING LV CONTRACTORS, MECHANICAL CONTRACTORS, AND BMO MANAGER. 5. ALL PUBLIC AREA RECEPTACLES ARE TO BE TAMPERPROOF. FLAG NOTES 1 1 1 POWER PLAN - ROOF E201 E No. E-24894 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN E E R ER FOETA T S A L I F O R N IATRICACELEL M A R K H. STEIN K E R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER 09/12/24 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT MB MHSMB 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT MB MHSISSUED FOR DESIGN DEVELOPMENT 2024-07-23 ISSUED FOR CLIENT REVIEW 2024-09-11 ISSUED FOR PERMIT AND BID 2024-09-12 PLAN CHECK #2 2024-10-281MBMHS MB MHS MB MHS UTIL 208Y/120V 3P 4W MSB 208Y/120V 3P 4W 1200A M 40 0 / 3 M 1A 208Y/120V 3P 4W 400A ALL SYSTEMS EXISTING. ELECTRICAL CONTRACTOR TO CONFIRM EACH EXISTING SYSTEM SPECIFICATIONS PRIOR TO WORK. THE ELECTRICAL SET PROVIDED DOES NOT ENSURE ACTUAL ON-SITE CONDITIONS . EXISTING SYSTEMS 200/3 1AA 208Y/120V 3P 4W 250A A B HP 40 0 / 3 25 0 / 3 ~~ CIRCUIT DESCRIPTION LOAD KVABKR CKT # CKT KVA CIRCUIT DESCRIPTIONBKR# LOADCKTCKT NOTE NEUTRAL BUS AMPS VOLTSPanel AIC MAIN BKR LUGSFED FROM MOUNTING ROOM STANDARD MLO 22,000 400 208Y/120V 3P 4W FLUSH1AMSB 100% a 21200/3 20/33.16 3.04 b 43 | | c | |5 6 a 8720/1 20/11.62 0.18 b 10920/1 30/20.9 4.5 c0.72 |20/111 12 a 141320/1 40/31.26 5.85 b 161520/1 |1.26 c0.72 |20/117 18 a 201920/1 35/31.08 4.54 b 222120/1 |0.72 c0.18 |20/123 24 a 262520/1 40/31.26 5.85 b 282720/1 |1.44 c1.44 |20/129 30 a 323120/1 20/11.08 0.066 b 343320/1 20/11.62 0 c 01.08 20/120/135 36 a 383720/1 20/10.72 0 b 403920/1 20/10.36 0 c 00.9 20/120/141 42 a 444320/1 20/10.54 0 b 464520/1 20/11.04 0 c 01.68 20/120/147 48 a 504920/1 20/10.18 0 b 525120/1 20/10.18 0 c 00.9 20/120/153 54 a 565520/1 20/10.9 0 b 585720/1 20/10.36 0 c 0020/120/159 60 a 626120/1 20/10 0 b 646320/1 20/10 0 c 0020/120/165 66 a 686720/1 20/10 0 b 706920/1 20/10 0 c 0020/120/171 72 CONN KVA CONN KVA CALC KVA CALC KVA LIGHTING 3.16 3.95 (125%) LARGEST MOTOR 5.85 1.46 (25%) MOTORS 23.9 23.9 (100%) RECEPTACLES 22.3 16.2 (50%>10) KITCHEN EQUIPMENT 1.5 1.5 (100%) NONCONTINUOUS 0.5 0.5 (100%) TOTAL LOAD 47.4 BALANCED 3-PHASE LOAD 132 A PHASE A 94.2% PHASE B 103% PHASE C 103% PANEL 1AA ROOM 104 POWERED DOOR, RECEPTACLE IDF ROOM 105, (E) ATM RECEPTACLE OFFICE 106 RECEPTACLE LOBBY OFFICE RECEPTACLE LOBBY OFFICE RECEPTACLE LOBBY OFFICE RECEPTACLE FOYER RECEPTACLE MEETING ROOM 109 RECEPTACLE LOBBY RECEPTACLE ROOM 114, CORRIDOR 116 RECEPTACLE OFFICE, 117, 118 RECEPTACLE TELLER, 120 RECEPTACLE TELLER RECEPTACLE ROOM 123 FLOOR BOX, RECEPTACLE ROOM 124 RECEPTACLE ROOM 122 RECEPTACLE LOBBY RECEPTACLE ROOM 105 RECEPTACLE KITCHEN 110 RECEPTACLE KITCHEN 110 RECEPTACLE, REFRIGERATOR KITCHEN 110 RECEPTACLE, SMALL APPLIANCE (E) BATHROOM RECEPTACLE (E) SD VAULT RECEPTACLE MEETING ROOM 109 RECEPTACLE ROOM 121 RECEPTACLE NIGHT DEPOSIT SPARE SPARE SPARE SPARE SPARE SPARE SPARE (N) CU-5 CONDENSATE PUMP (N) WH-1 (E) CU-3 (E) CU-2 (E) CU-1 (N) BEF-1, (N) BEF-2, (N) EF-1 SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE CIRCUIT DESCRIPTION LOAD KVABKR CKT # CKT KVA CIRCUIT DESCRIPTIONBKR# LOADCKTCKT NOTE NEUTRAL BUS AMPS VOLTSPanel AIC MAIN BKR LUGSFED FROM MOUNTING ROOM STANDARD MLO 22,000 250 208Y/120V 3P 4W FLUSH1AA1A 100% a 2120/1 20/10.1 0 b 4320/1 20/10.1 0 c 00.396 20/120/15 6 a 8720/1 20/10.602 0 b 10920/1 20/10.983 0 c 00.845 20/120/111 12 a 141320/1 20/10.13 0 b 161520/1 20/10 0 c 0020/120/117 18 a 201920/1 20/10 0 b 222120/1 20/10 0 c 0020/120/123 24 a 262520/1 20/10 0 b 282720/1 20/10 0 c 0020/120/129 30 a 323120/1 20/10 0 b 343320/1 20/10 0 c 0020/120/135 36 a 383720/1 20/10 0 b 403920/1 20/10 0 c 0020/120/141 42 CONN KVA CALC KVA CALC KVA LIGHTING 3.16 3.95 (125%)TOTAL LOAD 3.95 BALANCED 3-PHASE LOAD 11 A PHASE A 79.1% PHASE B 103% PHASE C 118% SITE LIGHTING SITE LIGHTING IDF ROOM LIGHTING 109, 110, BATHROOM LIGHTING TELLER, BOH LIGHTING LOBBY LIGHTING FRONT OFFICE LIGHTING SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE 1 1 FLAG NOTES 1.PANEL 1A AND PANEL 1AA CONDUCTORS AND PANELS EXISTING TO REMAIN. ELECTRICAL CONTRACTOR TO VERIFY EXISTING CONDITIONS. 2.ALL BUILDING ELECTRICAL (MSB, CONDUCTORS, METERS, ETC.) EXISTING TO REMAIN. ELECTRICAL CONTRACTOR TO VERIFYING EXISTING CONDITIONS. EXISTING CONDITIONS OUTSIDE OF DESIGN SCOPE OF WORK. # 2 M 1 1 ONE LINE DIAGRAM, PANEL SCHEDULES E300 E No. E-24894 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN E E R ER FOETA T S A L I F O R N IATRICACELEL M A R K H. STEIN K E R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER 09/12/24 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT MB MHSMB 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT MB MHSISSUED FOR DESIGN DEVELOPMENT 2024-07-23 ISSUED FOR CLIENT REVIEW 2024-09-11 ISSUED FOR PERMIT AND BID 2024-09-12 PLAN CHECK #2 2024-10-281MBMHS MB MHS MB MHS E300 E No. E-24894 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN E E R ER FOETA T S A L I F O R N IATRICACELEL M A R K H. STEIN K E R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER 09/12/24 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT MB MHSMB 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT MB MHSISSUED FOR DESIGN DEVELOPMENT 2024-07-23 ISSUED FOR CLIENT REVIEW 2024-09-11 ISSUED FOR PERMIT AND BID 2024-09-12 PLAN CHECK #2 2024-10-281MBMHS MB MHS MB MHS INTERIOR ENERGY FORMS E400 E No. E-24894 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN E E R ER FOETA T S A L I F O R N IATRICACELEL M A R K H. STEIN K E R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER 09/12/24 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT MB MHSMB 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT MB MHSISSUED FOR DESIGN DEVELOPMENT 2024-07-23 ISSUED FOR CLIENT REVIEW 2024-09-11 ISSUED FOR PERMIT AND BID 2024-09-12 PLAN CHECK #2 2024-10-281MBMHS MB MHS MB MHS EXTERIOR ENERGY FORMS E401 E No. E-24894 EXP. 12-31-24 C FO SRPDERE SIONAL E N G ITSIGN E E R ER FOETA T S A L I F O R N IATRICACELEL M A R K H. STEIN K E R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER 09/12/24 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT MB MHSMB 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT MB MHSISSUED FOR DESIGN DEVELOPMENT 2024-07-23 ISSUED FOR CLIENT REVIEW 2024-09-11 ISSUED FOR PERMIT AND BID 2024-09-12 PLAN CHECK #2 2024-10-281MBMHS MB MHS MB MHS BF P BF P 1 (E)PL2 (E) (E)(E)(E)(E) (E)(E)(E) SITE PLAN SCALE: 1/8" = 1'-0" (N)PL1 (E)PL2 (E)PL2(E)PL2 (E)PL2 (E)PL2 (N)WP1 (N)WP1 4 4 4 3 1 2 1 (TYP) 5 ES1 S3.2 1 GENERAL NOTES 1.EC TO COORDINATE WITH ALL EXISTING SITE CONDITIONS PRIOR TO LIGHTING INSTALLATION. 2.ALL LIGHTING WITH (E) LABEL DENOTES EXISTING LIGHTING FIXTURES. EXISTING FIXTURES UTILIZING GENERIC BASIS OF DESIGN FOR PHOTOMETRIC CALCULATIONS. ALL LIGHTING WITH (N) LABEL DENOTES NEW FIXTURE. 3.E.C. TO COORDINATE FINAL UTILITY EQUIPMENT LOCATIONS. 4.E.C. TO CONSULT UTILITY FOR MTS INSTALLATION. E.C. TO ADHERE TO LOCAL UTILITY REGULATIONS REGARDING SERVICE RATED MANUAL TRANSFER SWITCH INSTALLATION AND REGULATIONS. 5.PHOTOMETRIC CALCULATIONS PROVIDED IN 50' RADIUS OF ATM, IN ACCORDANCE WITH CALIFORNIA FINANCIAL CODE 13041. 6.LIGHTING CONTROLS SHALL BE INSTALLED WHICH MEET ALL REQUIREMENTS OF LOCAL ENERGY CODES. 7.ALL EXTERIOR MOUNTED LIGHTING SHALL BE CONTROLLED BY PHOTOCONTROL OR ASTRONOMIC TIME-CLOCK SCHEDULING PER CALIFORNIA ENERGY CODE (CENC) REQUIREMENTS 130.2. PROVIDE MOTION SENSING CONTROLS FOR LUMINAIRES OVER 40 WATTS MOUNTED LESS THAN 24' ABOVE GRADE AND WALL MOUNTED LUMINAIRES MORE THAN 24' ABOVE GRADE. 8.ALL EXTERIOR LIGHTING SHALL BE DIMMABLE. PROVIDE LIGHTING CONTROLS FOR HIGH END TRIM TO DIM LIGHT FIXTURES TO 80% OUTPUT AT INITIAL INSTALLATION. FUTURE MAINTENANCE SHALL INCREASE OUTPUT POWER TO MAINTAIN INITIAL LIGHT LEVEL. 9.ALL EXTERIOR MOUNTED LUMINAIRES SHALL FOLLOW MAXIMUM ALLOWABLE BACKLIGHT, UPLIGHT AND GLARE (BUG) RATINGS FOUND IN CALIFORNIA GREEN BUILDING STANDARDS CODE TABLE 5.106.8. FLAG NOTES 1.DOTTED LINE REPRESENT 50' RADIUS OF ATM, IN ACCORDANCE OF CALIFORNIA FINANCIAL CODE REQUIREMENT. 2.EXISTING WALL SCONCES EXISTING TO REMAIN TO MAINTAIN AESTHETIC APPEARANCE OF BANK EXTERIOR. 3.EXISTING LIGHTING FIXTURES HAVE BEEN ESTIMATED FOR PHOTOMETRIC PURPOSES AND ARE NOT INDICATIVE OF EXACT LUMINAIRES PRESENT IN EXISTING SPACES. 4.CONTRACTOR TO REUSE EXISTING CIRCUITRY FOR DUSK-TO-DAWN TIME CLOCK PRESENT FOR ALTERED/ADDED SITE LIGHTING LUMINAIRES. # 3 ARCADIA LUMINAIRE SCHEDULE CALLOUT SYMBOL DESCRIPTION MODEL INPUT VA NOTE 1 (E)PL2 LDXB Downlight 4" Wide Semi Diffuse White GE Current A Daintree LDXB4RX15T35XX_RDI4RWSDWTXX 14 Integrated Driver , N/ALumens scaled to claims (N)PL1 DSX1 LED P1 30K T4M MVOLT Lithonia Lighting, DSX1 LED P1 30K T4M MVOLT G1 54 BUG Rating: B1 U0 G2 (N)WP1 WDGE3 LED WITH P3 - PERFORMANCE PACKAGE, 3000K, 70CRI, FORWARD THROW OPTIC Lithonia Lighting, WDGE3 LED P3 70CRI RFT 30K 71.6952 BUG Rating: B2 U0 G2 NOTES: 1.CONTRACTOR TO FURNISH AND INSTALL ALL FIXTURES. 2.LUMINAIRE SCHEDULE IS BOD ONLY. CONTRACTOR TO SUBMIT FIXTURE MODEL OR EQUIVALENT. CONTRACTOR TO COORDINATE FIXTURE FINISHES WITH ARCHITECT/OWNER. 3.FIXTURE CATALOG NUMBERS DO NOT NECESSARILY DENOTE SPECIFIC MOUNTING ACCESSORIES. CONTRACTOR TO PROVIDE ALL NECESSARY ACCESSORIES TO SUCCESSFULLY COMPLETE THE INSTALLATION. 1 SITE LIGHTING ES1 R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PRELIMINARY NOT FOR CONSTRUCTION NOT FOR PERMITS, PRICING OR OTHER OFFICIAL PURPOSES. THIS DOCUMENT HAS NOT BEEN COMPLETED OR CHECKED AND IS FOR GENERAL INFORMATION OR COMMENT ONLY. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 BF P BF P 1 (E) (E)(E)(E)(E) (E)(E)(E) SITE PLAN SCALE: 1/8" = 1'-0" 4 4 4 4.3 9.1 10.2 3.1 4.5 4.3 7.3 14.2 13.6 3.6 5.1 6.2 10.2 10.6 8.1 2.3 3.3 4.7 5.9 10.8 7.7 2.0 3.1 4.3 5.8 5.88.1 10.7 3.4 11.6 24.7 2.6 4.4 10.1 7.8 2.2 3.3 4.9 10.0 7.6 2.7 3.9 5.3 3 2 (TYP) 5 ES1 S3.2 GENERAL PHOTOMETRIC NOTES 1.PHOTOMETRIC CALCULATIONS BASED ON AVAILABLE IES FILES FROM FIXTURE MANUFACTURER (OR EQUIVALENT). FIXTURE SUBSTITUTIONS MAY COMPROMISE FOOT CANDLE (FC) LEVELS. 2.PHOTOMETRIC CALCULATION ELEVATION FROM CEILING HEIGHT IN LUMINAIRE SCHEDULE ON SHEET ES1 OR ARCH/ID PLANS. 3.SITE PHOTOMETRIC: BASED ON PROPOSED SITE LIGHTING FOR PROJECT ONLY. 4.LIGHT TRESPASS: LIGHT SPILL PAST PROJECT SITE PROPERTY LINE. FLAG NOTES # 1.DOTTED LINE REPRESENT 50' RADIUS OF ATM, IN ACCORDANCE OF CALIFORNIA FINANCIAL CODE REQUIREMENT. 2.EXISTING WALL SCONCES EXISTING TO REMAIN TO MAINTAIN AESTHETIC APPEARANCE OF BANK EXTERIOR. 3.EXISTING LIGHTING FIXTURES HAVE BEEN ESTIMATED FOR PHOTOMETRIC PURPOSES AND ARE NOT INDICATIVE OF EXACT LUMINAIRES PRESENT IN EXISTING SPACES. 4.CONTRACTOR TO REUSE EXISTING CIRCUITRY AND DUSK-TO-DAWN TIME CLOCK PRESENT FOR ALTERED SITE LIGHTING LUMINAIRES. General Photometric Schedule AVERAGE FOOT-CANDLES 6.82 MAXIMUM FOOT-CANDLES 24.7 MINIMUM FOOT-CANDLES 2.0 MAXIMUM TO MINIMUM FC RATIO 12.53 AVERAGE TO MINIMUM FC RATIO 3.46 1 SITE PHOTOMETRICS ES2 R ENGINEERING, INC OBISON 19401 40th Ave W Suite 302, Lynnwood, WA 98036 Tel: 206-364-3343 Fax: 425-835-0098 Rei Project No.: 230-1995 Contact: SHAUN NEUBAUER THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS. DO NOT SCALE THE DRAWING - ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO STANTEC WITHOUT DELAY. THE COPYRIGHTS TO ALL DESIGNS AND DRAWINGS ARE THE PROPERTY OF STANTEC. REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY STANTEC IS FORBIDDEN. COPYRIGHT RESERVED TITLE CLIENT/PROJECT CLIENT/PROJECT LOGO CHKDDSGN DATEDWN NOTES ISSUED/REVISION BY APPD YYYY/MM/DD REVISION PROJECT NO.SCALE DRAWING NO. PRELIMINARY NOT FOR CONSTRUCTION NOT FOR PERMITS, PRICING OR OTHER OFFICIAL PURPOSES. THIS DOCUMENT HAS NOT BEEN COMPLETED OR CHECKED AND IS FOR GENERAL INFORMATION OR COMMENT ONLY. PERMIT/SEAL CONSULTANT 1045 W. HUNTINGTON DR. ARCADIA, CA 91007 BMO BANK N.A. TENANT IMPROVEMENT SS DRSS 2024/06/14 222702550 Stantec Architecture Inc. 224 South Michigan Avenue Suite 1400 Chicago, IL 60604-2590 TEL:(312) 554-1400 ISSUED FOR DESIGN DEVELOPMENT SS DR 2024/07/19 345 Pollasky Ave ∙ Clovis, California 93612 ∙ 559-323-9600 ∙ 559-323-9633 Fax STRUCTURAL ENGINEERING CALCULATIONS (PC RESPONSE) BMO BANK 1045 W. Huntington Dr. Arcadia, CA 91007 BYA# 24622 October 25, 2024 Prepared For: Stantec Architecture 224 South Michigan Ave, Suite 1400 Chicago, IL 60604 BMO - Bank Arcadia, CA STRUCTURAL PC RESPONSE: COMMENTS: 17: Provide a pole light footing detail... Response: Light pole footing detail can be found on structural sheet S3.2 detail 5. PLAN CHANGES: There were 2 (N) vault safes being added to the existing large bank vault. Sheet S2.1 has been updated to show this info and the attached calculation below have been added to check the slab for the safe bearing loads. __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave Clovis, California 93612 (559) 323-9600 (559) 323-9633 Fax __________________________ __________________________ Copyright 2024 Brad Young & Associates Print Date: 10/25/2024 File Name: 24622 - pc response.xmcd Engineer:_____CW_____ 1 ATTACHED CALCULATION PACKAGE __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave Clovis, California 93612 (559) 323-9600 (559) 323-9633 Fax __________________________ __________________________ Copyright 2024 Brad Young & Associates Print Date: 10/25/2024 File Name: 24622 - pc response.xmcd Engineer:_____CW_____ 2 ADD ITEM #1 Vault safes: There will be 2 ~10,000 lb vault safes added to the existing bank safe. Determine the minimum (E) safe slab thickness that will need to be field verified prior to installing these (N) units. There will be 2 units next to each other. Nunits 2:=Number of units DLsafe 10000lb 1000lb+11000lb=:=weight of unit + 1000# product load Lsafe 85in 7.083ft=:=Length of each unit Wsafe 34in 2.833ft=:=width of each unit Combined safe loading: DLsafe.total Nunits DLsafe 22000 lb=:= Lsafe.total Lsafe Nunits 14.167 ft=:= Wsafe 2.833ft= Check slab using a 6" thick equivalent footing that is 17' long x 4' wide with #4 bars @ 16" o.c. EA way. Existing min 6" slab w/ #4 bars @ 16" o.c. EA way is OK per attached Enercalc output. Contractor to field verify (E) vault slab thickness and rebar spacing prior to installing new units using GPR or similar __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave Clovis, California 93612 (559) 323-9600 (559) 323-9633 Fax __________________________ __________________________ Copyright 2024 Brad Young & Associates Print Date: 10/25/2024 File Name: 24622 - pc response.xmcd Engineer:_____CW_____ 3 Ge n e r a l F o o t i n g LIC # : K W - 0 6 0 1 8 1 8 1 , B u i l d : 2 0 . 2 4 . 0 3 . 0 4 BR A D Y O U N G & A S S O C I A T E S , I N C (c ) E N E R C A L C I N C 1 9 8 3 - 2 0 2 3 DE S C R I P T I O N : Va u l t s l a b c h e c k Pr o j e c t F i l e : 2 4 6 2 2 . e c 6 Pr o j e c t T i t l e : En g i n e e r : Pr o j e c t I D : Pr o j e c t D e s c r : Co d e R e f e r e n c e s Ca l c u l a t i o n s p e r A C I 3 1 8 - 1 9 , I B C 2 0 2 1 , A S C E 7 - 1 6 Lo a d C o m b i n a t i o n s U s e d : I B C 2 0 2 1 Ge n e r a l I n f o r m a t i o n Ma t e r i a l P r o p e r t i e s So i l D e s i g n V a l u e s 1. 5 0 An a l y s i s S e t t i n g s 25 0 . 0 ksi No ks f All o w a b l e S o i l B e a r i n g == 3. 0 60 . 0 3,1 2 2 . 0 2 14 5 . 0 = 0 . 3 0 Fle x u r e = 0 . 9 0 Sh e a r = Va l u e s 0. 0 0 1 8 0 So i l P a s s i v e R e s i s t a n c e ( f o r S l i d i n g ) 1.0 = In c r e a s e s b a s e d o n f o o t i n g p l a n d i m e n s i o n Ad d P e d e s t a l W t f o r S o i l P r e s s u r e No : Us e P e d e s t a l w t f o r s t a b i l i t y , m o m & s h e a r N o : All o w a b l e p r e s s u r e i n c r e a s e p e r f o o t o f d e p t h = ks f wh e n m a x . l e n g t h o r w i d t h i s g r e a t e r t h a n = ft : = Ad d F t g W t f o r S o i l P r e s s u r e Ye s Ye s : Us e f t g w t f o r s t a b i l i t y , m o m e n t s & s h e a r s wh e n f o o t i n g b a s e i s b e l o w ft pc f In c r e a s e B e a r i n g B y F o o t i n g W e i g h t = p c f Min . O v e r t u r n i n g S a f e t y F a c t o r = : 1 In c r e a s e s b a s e d o n f o o t i n g D e p t h 0.7 5 0 = So i l / C o n c r e t e F r i c t i o n C o e f f . Ec : C o n c r e t e E l a s t i c M o d u l u s == Fo o t i n g b a s e d e p t h b e l o w s o i l s u r f a c e ft = All o w p r e s s . i n c r e a s e p e r f o o t o f d e p t h ks f = : 1 1. 0 Min . S l i d i n g S a f e t y F a c t o r = = Co n c r e t e D e n s i t y = Min A l l o w % T e m p R e i n f . ks i f'c : C o n c r e t e 2 8 d a y s t r e n g t h fy : R e b a r Y i e l d ks i Min S t e e l % B e n d i n g R e i n f . So i l D e n s i t y = 11 0 . 0 p c f # Di m e n s i o n s Wid t h p a r a l l e l t o X - X A x i s 17 . 0 f t Le n g t h p a r a l l e l t o Z - Z A x i s = 4.0 f t = Pe d e s t a l d i m e n s i o n s . . . px : p a r a l l e l t o X - X A x i s 17 0 . 0 i n pz : p a r a l l e l t o Z - Z A x i s 34 . 0 i n He i g h t == in Fo o t i n g T h i c k n e s s = 6.0 i n = Re b a r C e n t e r l i n e t o E d g e o f C o n c r e t e . . . = in at B o t t o m o f f o o t i n g 3.0 Re i n f o r c i n g # Ba r s p a r a l l e l t o X - X A x i s Re i n f o r c i n g B a r S i z e = 4 Nu m b e r o f B a r s = 3.0 Ba r s p a r a l l e l t o Z - Z A x i s Re i n f o r c i n g B a r S i z e = 4 Nu m b e r o f B a r s = 12 . 0 Ba n d w i d t h D i s t r i b u t i o n C h e c k ( A C I 1 5 . 4 . 4 . 2 ) Dir e c t i o n R e q u i r i n g C l o s e r S e p a r a t i o n Bars a l o n g Z - Z A x i s # B a r s r e q u i r e d w i t h i n z o n e 38 . 1 % # B a r s r e q u i r e d o n e a c h s i d e o f z o n e 6 1 . 9 % Ap p l i e d L o a d s 22 . 0 D Lr ksf L S P : C o l u m n L o a d OB : O v e r b u r d e n = k W E M-z z V-x == k V-z k M-x x = k- f t = k- f t H = Ge n e r a l F o o t i n g LIC # : K W - 0 6 0 1 8 1 8 1 , B u i l d : 2 0 . 2 4 . 0 3 . 0 4 BR A D Y O U N G & A S S O C I A T E S , I N C (c ) E N E R C A L C I N C 1 9 8 3 - 2 0 2 3 DE S C R I P T I O N : Va u l t s l a b c h e c k Pr o j e c t F i l e : 2 4 6 2 2 . e c 6 Pr o j e c t T i t l e : En g i n e e r : Pr o j e c t I D : Pr o j e c t D e s c r : PA S S n/a S l i d i n g - X - X 0. 0 k 0. 0 k N o S l i d i n g PA S S n/a S l i d i n g - Z - Z 0. 0 k 0. 0 k N o S l i d i n g DE S I G N S U M M A R Y De s i g n O K Go v e r n i n g L o a d C o m b i n a t i o n Mi n . R a t i o I t e m Ap p l i e d Ca p a c i t y PA S S 0.2 6 4 0 S o i l B e a r i n g 0.3 9 6 0 k s f 1. 5 0 k s f D O n l y a b o u t Z - Z a xis PA S S n/a O v e r t u r n i n g - X - X 0. 0 k - f t 0. 0 k - f t N o O v e r t u r n i n g PA S S n/a O v e r t u r n i n g - Z - Z 0. 0 k - f t 0. 0 k - f t N o O v e r t u r n i n g PA S S n/a U p l i f t 0. 0 k 0. 0 k N o U p l i f t PA S S 0.2 3 5 6 Z F l e x u r e ( + X ) 0.4 5 3 8 k - f t / f t 1.9 2 6 k - f t / f t + 1 . 4 0 D PA S S 0.2 3 5 6 Z F l e x u r e ( - X ) 0.4 5 3 8 k - f t / f t 1.9 2 6 k - f t / f t + 1 . 4 0 D PA S S 0. 0 4 2 3 6 X F l e x u r e ( + Z ) 0.0 7 7 0 k - f t / f t 1.8 1 8 k - f t / f t + 1 . 4 0 D PA S S 0. 0 4 2 3 6 X F l e x u r e ( - Z ) 0.0 7 7 0 k - f t / f t 1.8 1 8 k - f t / f t + 1 . 4 0 D PA S S 0.1 7 8 4 1 - w a y S h e a r ( + X ) 14 . 9 7 2 p s i 83 . 9 4 5 p s i + 1 . 4 0 D PA S S 0.1 7 8 4 1 - w a y S h e a r ( - X ) 14 . 9 7 2 p s i 83 . 9 4 5 p s i + 1 . 4 0 D PA S S 0.1 2 3 3 1 - w a y S h e a r ( + Z ) 4.0 2 6 p s i 32 . 6 4 7 p s i + 1 . 4 0 D PA S S 0.1 2 3 3 1 - w a y S h e a r ( - Z ) 4.0 2 6 p s i 32 . 6 4 7 p s i + 1 . 4 0 D PA S S 0. 0 8 9 7 6 2 - w a y P u n c h i n g 8.4 2 8 p s i 93 . 8 9 5 p s i + 1 . 4 0 D De t a i l e d R e s u l t s Ro t a t i o n A x i s & Ze c c Xe c c Ac t u a l S o i l B e a r i n g S t r e s s @ L o c a t i o n Ac t u a l / A l l o w So i l B e a r i n g (in ) Gro s s A l l o w a b l e Bo t t o m , - Z T o p , + Z L e f t , - X R i g h t , + X Ra t i o Lo a d C o m b i n a t i o n . . . X- X , D O n l y 1.5 0 n/a 0.3 9 6 0 0 . 3 9 6 0 n/ a 0.2 6 4 0. 0 n/a X- X , + 0 . 6 0 D 1.5 0 n/a 0.2 3 7 6 0 . 2 3 7 6 n/ a 0.1 5 8 0. 0 n/a Z- Z , D O n l y 1.5 0 0. 3 9 6 0 n/ a n / a 0.3 9 6 0 0.2 6 4 n/ a 0.0 Z- Z , + 0 . 6 0 D 1.5 0 0. 2 3 7 6 n/ a n / a 0.2 3 7 6 0.1 5 8 n/ a 0.0 Ro t a t i o n A x i s & Ov e r t u r n i n g S t a b i l i t y Lo a d C o m b i n a t i o n . . . Sta t u s Ov e r t u r n i n g M o m e n t Re s i s t i n g M o m e n t S t a b i l i t y R a t i o Fo o t i n g H a s N O O v e r t u r n i n g Fle x u r e A x i s & L o a d C o m b i n a t i o n in ^ 2 i n ^ 2 in ^ 2 k-f t As R e q ' d Fo o t i n g F l e x u r e Te n s i o n k-ft Ac t u a l A s Sta t u s Mu S i d e Su r f a c e Gv r n . A s Ph i * M n X- X , + 1 . 4 0 D 0.0 7 7 0 + Z B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 4 1 2 1. 8 1 8 OK X- X , + 1 . 4 0 D 0.0 7 7 0 - Z B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 4 1 2 1. 8 1 8 OK X- X , + 1 . 2 0 D 0.0 6 6 0 + Z B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 4 1 2 1. 8 1 8 OK X- X , + 1 . 2 0 D 0.0 6 6 0 - Z B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 4 1 2 1. 8 1 8 OK X- X , + 0 . 9 0 D 0.0 4 9 5 0 + Z B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 4 1 2 1. 8 1 8 OK X- X , + 0 . 9 0 D 0.0 4 9 5 0 - Z B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 4 1 2 1. 8 1 8 OK Z- Z , + 1 . 4 0 D 0.4 5 3 8 - X B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 5 0 1. 9 2 6 OK Z- Z , + 1 . 4 0 D 0.4 5 3 8 + X B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 5 0 1. 9 2 6 OK Z- Z , + 1 . 2 0 D 0.3 8 9 0 - X B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 5 0 1. 9 2 6 OK Z- Z , + 1 . 2 0 D 0.3 8 9 0 + X B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 5 0 1. 9 2 6 OK Z- Z , + 0 . 9 0 D 0.2 9 1 7 - X B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 5 0 1. 9 2 6 OK Z- Z , + 0 . 9 0 D 0.2 9 1 7 + X B o t t o m 0 . 1 2 9 6 A C I 7 . 6 . 1 . 1 0 . 1 5 0 1. 9 2 6 OK On e W a y S h e a r X Vu @ + X Loa d C o m b i n a t i o n . . . Vu @ - X Vu : M a x Vu / P h i * V n Ph i V n Sta t u s +1 . 4 0 D 14 . 9 7 14 . 9 7 1 4 . 9 7 8 3 . 9 5 0 . 1 8 ps i ps i ps i ps i OK +1 . 2 0 D 12 . 8 3 12 . 8 3 1 2 . 8 3 8 3 . 9 5 0 . 1 5 ps i ps i ps i ps i OK +0 . 9 0 D 9. 6 3 9. 6 3 9 . 6 3 8 3 . 9 5 0 . 1 1 ps i ps i ps i ps i OK On e W a y S h e a r Z Lo a d C o m b i n a t i o n . . . Vu @ - Z V u @ + Z V u : M a x Vu / P h i * V n Ph i V n Sta t u s +1 . 4 0 D 4. 0 3 4 . 0 3 4 . 0 3 3 2 . 6 5 0 . 1 2 ps i ps i ps i ps i OK +1 . 2 0 D 3. 4 5 3 . 4 5 3 . 4 5 3 2 . 6 5 0 . 1 1 ps i ps i ps i ps i OK +0 . 9 0 D 2. 5 9 2 . 5 9 2 . 5 9 3 2 . 6 5 0 . 0 8 ps i ps i ps i ps i OK 4 Ge n e r a l F o o t i n g LIC # : K W - 0 6 0 1 8 1 8 1 , B u i l d : 2 0 . 2 4 . 0 3 . 0 4 BR A D Y O U N G & A S S O C I A T E S , I N C (c ) E N E R C A L C I N C 1 9 8 3 - 2 0 2 3 DE S C R I P T I O N : Va u l t s l a b c h e c k Pr o j e c t F i l e : 2 4 6 2 2 . e c 6 Pr o j e c t T i t l e : En g i n e e r : Pr o j e c t I D : Pr o j e c t D e s c r : Vu / P h i * V n Tw o - W a y " P u n c h i n g " S h e a r All u n i t s k Sta t u s Vu Ph i * V n Lo a d C o m b i n a t i o n . . . +1 . 4 0 D 8. 4 3 9 3 . 9 0 0 . 0 8 9 7 6 OK ps i ps i +1 . 2 0 D 7.2 2 93 . 9 0 0. 0 7 6 9 4 OK ps i ps i +0 . 9 0 D 5.4 2 93 . 9 0 0. 0 5 7 7 1 OK ps i ps i 5 345 Pollasky Ave ∙ Clovis, California 93612 ∙ 559-323-9600 ∙ 559-323-9633 Fax STRUCTURAL ENGINEERING CALCULATIONS (Tenant Improvement) BMO BANK 1045 W. Huntington Dr. Arcadia, CA 91007 BYA# 24622 September 12, 2024 Prepared For: Stantec Architecture 224 South Michigan Ave, Suite 1400 Chicago, IL 60604