HomeMy WebLinkAbout12339 Lower Azusa Rd - 2025 - Proposed cabling area tables, desks, and working benches.NEW 16" PUBLIC WATER MAIN (N) PUB F.H. (N) PUB F.H. NEW 16" PUBLIC WATER MAIN NEW 1 6 " P U B L I C W A T E R M A I NBLDG 1 - DCDA #1BLDG 1 - DCDA #2BLDG 2DCDA #1 BLDG 2DCDA #2 BLDG 3 - DCDA #1 BLDG 3DCDA #2 (N) PUB F.H.(N) PUB F.H. L O W E R A Z U S A R D LOWER AZUSA RD NE W 1 6 " P U B L I C W A T E R M A I N (E) PUB F.H. (E) PUB F.H. (E) PUB F.H. (E) P U B F.H. (E) P U B F.H. (E) 16" PUBLIC WATER MAIN (E) 16" P U B LIC W A T E R M AIN BUILDING 1 WORK AREA SE T B A C K 60 ' - 0 " SETBACK 77' - 0" SETBACK 65' - 0" SE T B A C K 18 5 ' - 0 " PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E T.O.W. TYP. T.S.B. T.O.S. T.O.P. T.O.R. T.S. T.O.C. T.O.CL. REF. S.G. S.F. SS S M.T. F.D. H.B. F.E. F.S. FHC F.O.S. F.E.W. F.F. F.O.C. F.S.S. B.O.B. F.O.B. EXP. (E) DF LC A.F.L. B.W. A.F.F. F.E.B. OCC. OL EXIT BATTERY BACK UP EMERGENCY LIGHT W/EXIT COMBINATION, REFER TO ELECTRICAL FOR PLACEMENT SURFACE MOUNTED ILLUMINATED EXIT SIGN WITH DIRECTIONAL ARROWS IF APPLICABLE -WHERE INDICATED. UNLESS OTHERWISE NOTED.W/ 2A:10B:C TOP OF SPANDREL BEAM TOP OF WALL TYPICAL TOP OF SLAB TOP OF SHEATHING TOP OF CLADDING TOP OF RAILING TOP OF PARAPET TOP OF CURB REFRIGERATOR SLAB ON GRADE SQUARE FEET SERVICE SINK SINK MARBLE THRESHOLD FIRE EXTINGUISHER CABINET FINISH SURFACE FIRE HOSE CABINET FLOOR DRAIN HOSE BIB FACE OF CONCRETE FACE OF STUD FACE OF EXISTING WALL FACE OF STUCCO SURFACE FINISH FLOOR BOTTOM OF BEAM FACE OF BLOCK DRINKING FOUNTAIN EXPOSED EXISTING CENTER LINE BACK OF WALK ABOVE FINISH LEVEL ABOVE FINISH FLOOR FIRE EXTINGUISHER BRACKET MOUNTED OCCUPANCY OCCUPANCY LOAD UNLESS OTHERWISE NOTED.W/ 2A:10B:C EMERGENCY LIGHT, REFER TO ELECTRICAL FOR PLACEMENT EXIT E.EMERGENCY LIGHTING W/ 90MIN. BATTERY BACKUP. SPECIFIC PLAN MITIGATION MEASURES MM 4.2-1 PRIOR TO BUILDING PERMIT ISSUANCE, THE CITY OF ARCADIA SHALL VERIFY THAT THE FOLLOWING NOTE IS SPECIFIED ON ALL BUILDING PLANS. PROJECT CONTRACTORS SHALL BE REQUIRED TO COMPLY WITH THE NOTE AND MAINTAIN WRITTEN RECORDS OF SUCH COMPLIANCE THAT CAN BE INSPECTED BY THE CITY OF ARCADIA UPON REQUEST. THIS NOTE ALSO SHALL BE SPECIFIED IN BID DOCUMENTS ISSUED TO PROSPECTIVE CONSTRUCTION CONTRACTORS. “ALL SURFACE COATINGS SHALL CONSIST OF “ZERO-VOLATILE ORGANIC COMPOUND”PAINTS (NO MORE THAN 100 GRAM/LITER OF VOC) AND/OR HIGH PRESSURE LOW VOLUME (HPLV) APPLICATIONS CONSISTENT WITH SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1113.” MM 4.2-7 THE BUILDING PLANS FOR EACH BUILDING SHALL REQUIRE LIGHT-COLORED ROOF MATERIALS. LIGHT COLORED ROOF MATERIALS ARE MORE SOLAR-REFLECTIVE THAN DARK COLORED ROOFS; LIGHT COLOR ROOFS KEEP BUILDINGS COOLER AND REDUCE LOCAL AIR TEMPERATURES, WHICH IN TURN IMPROVES AIR QUALITY AND SLOWS SMOG FORMATION. THE CITY OF ARCADIA SHALL VERIFY THIS INFORMATION IS PROVIDED ON THE PROJECT’S BUILDING PLANS PRIOR TO ISSUANCE OF BUILDING PERMITS AND INSPECT FOR ADHERENCE DURING BUILDING CONSTRUCTION. MM 4.5-1 PRIOR TO BUILDING PERMIT ISSUANCE, THE CITY OF ARCADIA SHALL VERIFY THAT THE FOLLOWING NOTES ARE SPECIFIED ON ALL BUILDING PLANS. PROJECT CONTRACTORS SHALL BE REQUIRED TO COMPLY WITH THE NOTES AND MAINTAIN WRITTEN RECORDS OF SUCH COMPLIANCE THAT CAN BE INSPECTED BY THE CITY OF ARCADIA UPON REQUEST. THESE NOTES ALSO SHALL BE SPECIFIED IN BID DOCUMENTS ISSUED TO PROSPECTIVE CONSTRUCTION CONTRACTORS. A) COMPREHENSIVE CONSTRUCTION MANAGEMENT PLAN SHALL BE PREPARED AND IMPLEMENTED THAT IS DESIGNED TO MINIMIZE THE NUMBER OF LARGE CONSTRUCTION EQUIPMENT OPERATING DURING ANY GIVEN TIME PERIOD. B) GASOLINE-POWERED EQUIPMENT SHALL BE EQUIPPED WITH CATALYTIC CONVERTERS. C) ELECTRICAL POWERED EQUIPMENT SHALL BE UTILIZED IN-LIEU OF GASOLINE-POWERED ENGINES WHERE FINANCIALLY AND TECHNICALLY FEASIBLE AND COMMERCIALLY AVAILABLE. PROVIDE TEMPORARY TRAFFIC CONTROLS SUCH AS A FLAG PERSON, DURING ALL PHASES OF CONSTRUCTION TO MAINTAIN SMOOTH TRAFFIC FLOW ON PUBLIC STREETS ADJACENT TO THE PROJECT SITE. MM 4.5-2 BUILDING AND SITE PLAN DESIGNS SHALL ENSURE THAT PROJECT ENERGY EFFICIENCIES SURPASS (EXCEED) APPLICABLE (2014) CALIFORNIA TITLE 24 ENERGY EFFICIENCY STANDARDS BY A MINIMUM OF 5%. VERIFICATION OF INCREASED ENERGY EFFICIENCIES SHALL BE DOCUMENTED IN TITLE 24 COMPLIANCE REPORTS PROVIDED BY THE APPLICANT, AND REVIEWED AND APPROVED BY THE CITY OF ARCADIA PRIOR TO THE ISSUANCE OF THE FIRST BUILDING PERMIT. MM 4.9-2 PRIOR TO THE ISSUANCE OF ANY BUILDING OR GRADING PERMITS, THE CITY OF ARCADIA DEVELOPMENT SERVICES DEPARTMENT SHALL REVIEW BUILDING AND GRADING PLANS TO ENSURE THAT THE FOLLOWING NOTES ARE INCLUDED. PROJECT CONTRACTORS SHALL BE REQUIRED TO COMPLY WITH THESE NOTES AND MAINTAIN WRITTEN RECORDS OF SUCH COMPLIANCE THAT CAN BE INSPECTED BY THE CITY OF ARCADIA UPON REQUEST. A) CONSTRUCTION CONTRACTORS SHALL EQUIP ALL CONSTRUCTION EQUIPMENT, FIXED OR MOBILE, WITH PROPERLY OPERATING AND MAINTAINED MUFFLERS, CONSISTENT WITH MANUFACTURERS’STANDARDS. THE CONSTRUCTION CONTRACTOR SHALL PLACE ALL STATIONARY CONSTRUCTION EQUIPMENT SO THAT EMITTED NOISE IS DIRECTED AWAY FROM THE NOISE SENSITIVE RECEPTORS NEAREST THE PROJECT SITE. B) CONSTRUCTION CONTRACTORS SHALL LOCATE EQUIPMENT STAGING AREAS (AREAS WHERE LARGE PIECES OF CONSTRUCTION EQUIPMENT ARE STORED WHEN NOT IN OPERATION) A MINIMUM DISTANCE OF 200 FEET AWAY FROM NOISE-SENSITIVE RECEIVERS NEAREST THE PROJECT SITE (I.E., TO THE WEST) DURING ALL PROJECT CONSTRUCTION. C) CONSTRUCTION CONTRACTORS SHALL LIMIT HAUL TRUCK DELIVERIES TO THE SAME HOURS SPECIFIED FOR CONSTRUCTION EQUIPMENT (BETWEEN THE HOURS OF 7:00 A.M. AND 7:00 P.M., MONDAY THROUGH SATURDAY, UNLESS OTHERWISE PERMITTED BY THE DEVELOPMENT SERVICES DEPARTMENT. CONSTRUCTION IS PROHIBITED ON SUNDAYS AND MAJOR HOLIDAYS.). D) TO LIMIT HAUL TRUCK NOISE TO SENSITIVE RECEPTORS, HAUL TRUCKS MUST ENTER AND LEAVE THE PROJECT SITE BY LOWER AZUSA ROAD, TOWARD I-605. HAUL TRUCKS SHALL NOT BE PERMITTED TO LEAVE THE SITE AND TURN RIGHT ON LOWER AZUSA ROAD. SIGNS MUST BE INSTALLED AT ALL CONSTRUCTION EXIT DRIVEWAYS DIRECTING DRIVERS TO TURN LEFT ONTO LOWER AZUSA ROAD TOWARD I-605. E) ANY PROJECT-RELATED CONSTRUCTION ACTIVITY PLANNED DURING THE EVENING (7:00 P.M. TO 10:00 P.M.) OR LATE NIGHT/EARLY MORNING HOURS (10:00 P.M. TO 7:00 A.M.) REQUIRES DISCLOSURE TO ALL PROPERTIES WITHIN 300 FEET, AND/OR AS OTHERWISE REQUIRED BY THE CITY OF ARCADIA OR REQUESTED BY THE CITY OF EL MONTE, AND SHALL NOT TAKE PLACE WITHIN 40 FEET OF NEARBY SENSITIVE RECEIVERS. TO CONDUCT WORK DURING THESE EVENING AND LATE NIGHT/EARLY MORNING HOURS, THE CONSTRUCTION CONTRACTOR MUST DEMONSTRATE TO THE CITY OF ARCADIA IN THE FORM OF A NOISE ANALYSIS PREPARED BY A QUALIFIED ACOUSTICAL ENGINEER THAT CONSTRUCTION NOISE LEVELS AFFECTING RESIDENTIAL RECEIVERS IN THE CITY OF EL MONTE BETWEEN 7:00 P.M. AND 7:00 A.M. WOULD FALL AT OR BELOW THE FOLLOWING LEVELS: 45 LEQ AVERAGE; 50 L25 (15 MINUTE); 55 L8 (5 MINUTE) AND 60 LMAX (<1 MINUTE). MM 4.10-4 PRIOR TO THE ISSUANCE OF GRADING OR BUILDING PERMITS, THE PROJECT APPLICANT SHALL PREPARE AND THE CITY OF ARCADIA SHALL APPROVE A TEMPORARY TRAFFIC CONTROL PLAN. THE TEMPORARY TRAFFIC CONTROL PLAN SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. A REQUIREMENT TO COMPLY WITH THE TEMPORARY TRAFFIC CONTROL PLAN SHALL BE NOTED ON ALL GRADING AND BUILDING PLANS AND ALSO SHALL BE SPECIFIED IN BID DOCUMENTS ISSUED TO PROSPECTIVE CONSTRUCTION CONTRACTORS. THE TEMPORARY TRAFFIC CONTROL PLAN SHALL REQUIRE THE FOLLOWING: A) DELIVERY TRUCKS SHALL UTILIZE THE MOST DIRECT ROUTE BETWEEN THE SITE AND I-605 VIA LOWER AZUSA ROAD; B) EXCEPT FOR THE SEGMENT OF LOWER AZUSA ROAD BETWEEN THE SITE AND I-605, THE CONSTRUCTION CONTRACTOR SHALL ASSURE THAT CONSTRUCTION-RELATED HAUL TRIPS, INCLUDING BUT NOT LIMITED TO THE TRANSPORTATION OF CONSTRUCTION MATERIALS, EARTH MATERIALS, AND/OR HEAVY EQUIPMENT TO AND FROM THE PROJECT SITE BE LIMITED TO NO MORE THAN 50 PASSENGER CAR EQUIVALENT (PCE) TRIPS (I.E., 25 INBOUND AND 25 OUTBOUND TRIPS, OR ANY COMBINATION THEREOF) DURING THE AM PEAK HOUR (7:00AM-9:00AM) AND THE PM PEAK HOUR (4:00PM-6:00PM) ON LOCAL ROADS. A TWO-AXLE TRUCK TRIP IS THE EQUIVALENT OF 1.5 PCE TRIPS; A THREE-AXLE TRUCK TRIP IS THE EQUIVALENT OF 2.0 PCE TRIPS; AND A FOUR-AXLE OR LARGER TRUCK TRIP IS THE EQUIVALENT OF 3.0 PCE TRIPS. RR-NOISE-4 PRIOR TO ISSUANCE OF DISCRETIONARY PERMITS FOR CONSTRUCTION ACTIVITIES, PROJECT APPLICANTS/DEVELOPERS SHALL SUBMIT EVIDENCE TO THE DIRECTOR OF DEVELOPMENT SERVICES THAT THE FOLLOWING NOISE REDUCTION MEASURES ARE STATED AS REQUIREMENTS ON THE CONSTRUCTION PLANS AND SPECIFICATIONS: A) DURING ALL EXCAVATION AND GRADING, THE CONSTRUCTION CONTRACTORS SHALL EQUIP ALL CONSTRUCTION EQUIPMENT, FIXED OR MOBILE, WITH PROPERLY OPERATING AND MAINTAINED MUFFLERS, CONSISTENT WITH MANUFACTURERS’STANDARDS. THE CONSTRUCTION CONTRACTOR SHALL PLACE ALL STATIONARY CONSTRUCTION EQUIPMENT SO THAT EMITTED NOISE IS DIRECTED AWAY FROM THE NOISE-SENSITIVE RECEPTORS. B) WHEN FEASIBLE, THE CONSTRUCTION CONTRACTOR SHALL LOCATE EQUIPMENT STAGING IN AREAS THAT WILL CREATE THE GREATEST DISTANCE BETWEEN CONSTRUCTION-RELATED NOISE SOURCES AND NOISE SENSITIVE RECEPTORS DURING ALL PROJECT CONSTRUCTION. C) THE CONSTRUCTION CONTRACTOR SHALL LIMIT ALL CONSTRUCTION-RELATED ACTIVITIES THAT WOULD RESULT IN HIGH NOISE LEVELS, ACCORDING TO THE CONSTRUCTION HOURS SET FORTH IN THE MUNICIPAL CODE. D) THE CONSTRUCTION CONTRACTOR SHALL LIMIT HAUL TRUCK DELIVERIES TO THE SAME HOURS SPECIFIED FOR CONSTRUCTION EQUIPMENT. TO THE EXTENT FEASIBLE, HAUL ROUTES SHALL NOT PASS SENSITIVE LAND USES OR RESIDENTIAL DWELLINGS. CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 3/ 3 / 2 0 2 5 8: 5 5 : 1 7 A M 3/3/2025 8:55:17 AM T8-1.0 CO V E R P A G E 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1257-21 GL E N A I R L O G I S T I C S - BL D G 1 10 / 2 8 / 2 1 Au t h o r Ch e c k e r GLENAIR LOGISTICS -BUILDING 1 12339 LOWER AZUSA ROAD ARCADIA, CA 91006 Vicinity Map SITE PLAN CONSULTANT INDEX: TENANT: PROJECT ARCHITECT: PROJECT DEVELOPER: MECHANICAL ENGINEER: ELECTRICAL ENGINEER: SHEET INDEX: APPLICABLE CODES:2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECRTICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STDS. 2022 CALIFORNIA FIRE CODE (CFC) ZONE:ARCADIA LOGISTICS CENTER SPECIFIC PLAN AREA OF LOT: LEGAL DESCRIPTION: ASSESSOR'S ID NO. : OCCUPANCY TYPE: PARKING REQUIRED: PARKING PROVIDED: EXISTING LANDSCAPE AREA: BUILDING SPRINKLER: PHASE VIII -CABLING 413,939 SF 9.50 ACRES 8541-017-027 AND 8541-017-028 B / S-1 / F-1 / A-2 10,000 SF OFFICE @ 1/250 THE LAND REFFERED TO HEREIN BELOW IS SITUATED IN THE CITY OF ARCADIA, IN THE COUNTY OF LOS ANGELES, STATE OF CALIFORNIA , AND IS DESCRIBED AS FOLLOWS. THAT PORTION OF LOT 1 OF TRACT NO. 10369, IN THE CITY OF ARCADIA, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AS PER MAP RECORD IN BOOK 149, PAGES 95 AND 96, OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, LYING WESTERLY AND NORTHWESTERLY OF THE WESTERLY LINE OF THE LAND DESCRIBED IN THE CONDEMNATION OF ACTION , CASE NO. 574211, SUPERIOR COURT OF SAID COUNTY, A CERTIFIED COPY OF THE DECREE HAD IN SAID ACTION WAS RECORDED IN BOOK 38373, PAGE 153, OF OFFICE RECORDES. EXCEPT AN UNDIVIDED 75 PER CENT OF ALL OIL, GAS AND OTHER HYDROCARBON SUBSTANCES IN AND UNDER SAID LAND, WITH RIGHT OF INGRESS AND EGRESS NECESSARY FOR THE MINING AND REMOVAL OF SAME, AS RESERVED BY MARTIN WUNDERLICH, E.MURIELLE WUNDERLICH, GEORGE P. LEONARD AND WILM LEONARD, BY DEED RECORDED FEBRUARY 4, 1955 AS INSTRUMENT NO. 470, IN BOOK 46821, PAGE 149, OF OFFICIAL RECORDES. FULLY SPRINKLERED ESFR SITE INFORMATION - CABLING AREA TABLES, DESKS AND WORKING BENCHES (±72,200 sq.ft.) - NO CHANGE OF OCCUPANCY AND INCREASE IN BUILDING SQ.FT. (E) BUILDING AREA: 200,387 SFGROUND FLOOR: 5,036 SFMEZZANINE: 205,423 SF 40 STALLS 10,000 SF WH/MANUF (0K-10K) @ 1/1,000 10 STALLS 10,000 SF WH/MANUF (10K-20K) @ 1/3,000 3 STALLS 175,423 SF WH/MANUF (20K+) @ 1/5,000 35 STALLS 88 STALLSTOTAL PARKING REQUIRED: CURRENT STALLS STRIPED 95 STALLS PROPOSED TEMPORARY COVID MITIGATION PARKING STALL STRIPPING. 46 STALLS 137 STALLSTOTAL: 60,701 SF COVERAGE:14.66% PREFERED PARKING STALLS REQUIRED FOR LOW EMITTING & FUEL EFFICIENT VEHICLES PER CALGREEN TABLE 5.106.5.2 8 STALLS PREFERED PARKING STALLS PROVIDED: 10 STALLS BIKE PARKING REQUIRED: 5 BIKESCALGREEN @ MIN. 5% OF AUTO STALLS PROVIDED: BIKE PARKING PROVIDED: 5 BIKES ACCESSIBLE STALLS: CODE SUMMARY PROJECT DATA STANDARD: VAN: 3 1 4TOTAL: CONSTRUCTION TYPE: TYPE III-B AREA JUSTIFICATION:UNLIMITED FOUR SURROUNDING SIDEYARDS OF 40' AND 60' PER CBC 507 AND 507.5 BUILDING CODE ALLOW HEIGHT: 50' + 20' = 70 FEET - SECTION 504.2 PROJECT SCOPE OF WORK PROPOSED PARKING ALTERATION: TOTAL NO. OF STALLS REMOVED: -4 STALLS GLENAIR, INC. 1211 AIR WAY GLENDALE, CA 91201 (818) 247-6000 MALEKIAN and ASSOCIATES, Inc. Alen Malekian, AIA, NCARB 2255 HONOLULU AVE. SUITE 1A MONTROSE, CA 91020 (818) 249-5522 GEROGE C. HOPKINS CONSTRUCTION 919 WEST GLENAOKS BLVD. GLENDALE, CA 91202 STALLS REMOVED FOR ELECTRICAL PAD ADDITION:-4 STALLS ARCHITECTURAL LEGENDS AND ABBREVIATION: 8M-0.0 SHEET INDEX, MANDATORY NOTES & KEYPLAN 8M-1.0 EQUIP'T SCHED'L, NOTES & DETAILS 8M-2.0 OVERALL HVAC FLOOR PLAN 8M-3.0 PARTIAL HVAC FLOOR PLAN 8M-4.0 OVERALL HVAC FLOOR PLAN 8M-5.0 T-24 COMPLIANCE ENERGY FORMS T8-1.0 COVER PAGE T8-1.1 OCCUPANCY AND EXITING DIAGRAMS T8-1.2 FIRE EXTINGUISHER PLAN A8-1.0 SITE PLAN A8-2.0 OVERALL GROUND LEVEL PLAN A8-2.1 FURNITURE ENLARGED PLANS MECHANICAL KENT ELECTRIC, INC. 6655 SAN FERNANDO ROAD GLENDALE, CA 91201 (818) 247-1192 E-1.0 FRONT SHEET E-2.0 POWER PLAN E-3.0 PANEL SCHEDULES E-4.0 SINGLE LINE DIAGRAM E-5.0 ELECTRICAL SPECIFICATIONS ELECTRICAL THERMA, LLC. 2390 BATEMAN AVE. IRWINDALE, CA 91010 (626) 446-1854 UP UP G F E D C B A 1 1 2 2 3 3 4 5 6 7 8 9 10 11 12 13 F.6 3.52.5 E.9 F.4 EXISTING WAREHOUSE / MANUFACTURING 100 (E)ELEC RM 101 (E)VESTIBULE 102 177,894 sf F-1 / S-1 (MODERATE HAZARD FACTORY INDUSTRIAL / MODERATE HAZARD STORAGE) OCCUPANCY CALCULATIONS AREA LOAD FACTOR TABLE 1004.5 INDUSTRIAL - 100 GROSS 1,778.94 NO. OF OCCUPANTS EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXIT EXITEXITEXITEXITEXIT EXITEXIT EXIT EXIT EXIT EXIT 2,000 sf A-2 (ASSEMBLY INTENDED FOR FOOD AND OR DRINK CONSUMPTION) OCCUPANCY CALCULATIONS (BREAK ROOMS) AREA LOAD FACTOR TABLE 1004.5 ASSEMBLY W/O FIXED SEATS - 15 NET 133.33 NO. OF OCCUPANTS 1,884 sf (EA.) A-2 (ASSEMBLY INTENDED FOR FOOD AND OR DRINK CONSUMPTION) OCCUPANCY CALCULATIONS (BREAK ROOMS) AREA LOAD FACTOR TABLE 1004.5 ASSEMBLY W/O FIXED SEATS - 15 NET 125.6 NO. OF OCCUPANTS 920 sf A-2 (ASSEMBLY INTENDED FOR FOOD AND OR DRINK CONSUMPTION) OCCUPANCY CALCULATIONS (BREAK ROOMS) AREA LOAD FACTOR TABLE 1004.5 ASSEMBLY W/O FIXED SEATS - 15 NET 61.33 NO. OF OCCUPANTS 4,125 sf B (BUISINES GROUP) OCCUPANCY CALCULATIONS (OFFICES) AREA LOAD FACTOR TABLE 1004.5 UNCONCENTRATED - 150 GROSS 27.5 NO. OF OCCUPANTS EXIT (EXISTING) (EXISTING) (EXISTING) (EXISTING) (EXISTING -PARTIALLY RENOVATED ) 88' TRAVEL DISTANCE MAXIMUM TRAVEL DISTANCE 300' PER TABLE 1017.2 CBC 2022 (712'-6"x1/3=237'-6") 10 07.1 .1 CBC 20 22 20 5 ' T R A V E L D I S T A N C E MA X I M U M T R A V E L D I S T A N C E 2 5 0 ' PE R T A B L E 1 0 1 7 . 2 C B C 2 0 2 2 16 0 ' T R A V E L D I S T A N C E MA X I M U M T R A V E L D I S T A N C E 2 5 0 ' PE R T A B L E 1 0 1 7 . 2 C B C 2 0 2 2 94' TRAVEL DISTANCE MAXIMUM TRAVEL DISTANCE 250' PER TABLE 1017.2 CBC 2022 EXISTING FURNITURE TO REMAIN 116' TRAVEL DISTANCE MAXIMUM TRAVEL DISTANCE 250' PER TABLE 1017.2 CBC 2022 127' TRAVEL DISTANCE MAXIMUM TRAVEL DISTANCE 250' PER TABLE 1017.2 CBC 2022 120' TRAVEL DISTANCE MAXIMUM TRAVEL DISTANCE 250' PER TABLE 1017.2 CBC 2022 17 7 ' T R A V E L D I S T A N C E MA X I M U M T R A V E L D I S T A N C E 2 5 0 ' PE R T A B L E 1 0 1 7 . 2 C B C 2 0 2 2 162' TRAVEL DISTANCE MAXIMUM TRAVEL DISTANCE 250' PER TABLE 1017.2 CBC 2022 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 61' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"59' - 0"640' - 0" 14' - 3"8' - 0"9' - 5"10' - 8"9' - 0"15' - 7" TY P . 3' - 6 " 9' - 6" 9' - 7" 8' - 4" TY P . 6' - 8 1 / 2 " 6' - 7 " 7' - 6 1 / 2 " 24 ' - 0 " 6' - 1 0 " 6' - 8 " 11 ' - 1 1 1 / 2 " 6' - 2 1 / 2 " 7' - 6 " 6' - 8 1 / 2 " 7' - 0 " 6' - 8 1 / 2 " 7' - 0 " 6' - 5 1 / 2 " 6' - 6 " 6' - 8 1 / 2 " 7' - 6 " TY P . 6' - 8 1 / 2 " 6' - 1 0 " 6' - 1 0 " 47 ' - 6 1 / 2 " 25 ' - 7 1 / 2 " TY P . 3' - 6 " CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 3/ 3 / 2 0 2 5 8: 1 8 : 4 3 A M 3/3/2025 8:18:43 AM T8-1.1 OC C U P A N C Y A N D E X I T I N G D I A G R A M S 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1257-21 GL E N A I R L O G I S T I C S - BL D G 1 06 / 0 3 / 2 0 Au t h o r Ch e c k e r 1/32" = 1'-0"1 GROUND LEVEL FLOOR PLAN - CODE DIAGRAM PHASE VIII UP UP G F E D C B A 1 1 2 2 3 3 4 5 6 7 8 9 10 11 12 13 F.6 3.52.5 E.9 F.4 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 61' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"59' - 0" 640' - 0" NORTH (E) ROOF ACCESS LADDER (E) EQUIPMENT CANOPY (E) CANOPY "A" (E) CANOPY "B" (E) CANOPY "D" PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR,ALSO DURING CONSTRUCTION CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 3/ 3 / 2 0 2 5 8: 1 8 : 5 8 A M 3/3/2025 8:18:58 AM T8-1.2 FI R E E X T I N G U I S H E R P L A N 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1257-21 GL E N A I R L O G I S T I C S - BL D G 1 11 / 0 5 / 2 4 Au t h o r Ch e c k e r 1" = 20'-0"1 OVERALL GROUND LEVEL FIRE EXTINGUISHER PLAN - PHASE VIII BLDG 1 - DCDA #1BLDG 1 - DCDA #2 R D (E) PUB F.H. (E) P U B F.H. ( E ) P U B F. H . (E) 1 6 " P U B LIC W A T E R M AI N G F E D C B A 1 1 2 2 3 3 4 5 6 7 8 9 10 11 12 13 F.6 3.52.5 E.9 F.4 2' - 5 3 / 4 " 0' - 0 1 / 4 " NORTH 47 47 48 48 48 48 43 44 13 19 31 24 18 42 2 3 4 7 8 9 11 16 37 20 12 22 23 2525 1 22 22 CV CV CV CV CV CV CV 32 38 38 38 38 6 27 27 W 30 CV CV CV 28 45 10 35 36 46 85 ' - 0 " 10 0 ' - 0 " 49 50 48 18 ' - 0 " 53 52 CANOPY 'C' 51 51 51 CANOPY 'A'CANOPY 'B'CANOPY 'D' 54 1. PUBLIC STREET : ALL IMPROVEMENTS INCLUDING SIDEWALKS, CURB CUTS AND DRIVEWAY APRONS ARE TO BUILT TO CITY / COUNTY STANDARD PER APPROVED CIVIL DRAWINGS. 2. (E) CURB CUT. SEE CIVIL DRAWINGS FOR IMPROVEMENTS. 3. (E) STREET FIRE HYDRANT. SEE CIVIL DRAWINGS. 4. (E) STREET LIGHT. SEE CIVIL DRAWINGS. 5. (E) ACCESSIBLE PARKING STALL COMPLIANCE SIGNAGE AT DRIVEWAY ENTRANCES INTOSITE. 6. (E) FIRE DEPARTMENT CONNECTION. SEE FIRE PROTECTION DRAWINGS. 7. (E) FIRE BACKFLOW PREVENTER TO BE SCREENED WITH LANDSCAPE. SEE FIRE PROTECTIONDRAWINGS. 8. (E) IRRIGATED LANDSCAPING PER GUIDELINES WITH MIN 6"CONCRETE CURBS AT ALL INTERIOR PERIMETERS. SEE LANDSCAPE DRAWINGS. 9.(E) MEDIUM BROOM FINISH CONCRETE SIDE WALK: MIN. 4.5" THK. 2500PSI WITH #3 BARS @ 18" O.C. EA. WAY OVER 95% COMPACTED 12" SUBGRADE. PROVIDECONTROL / CONSTRUCTION JOINTS @ MAX. 5'-0" O.C. SHADED AREAS: #5 TOP-CAST WASHFINISHED CONCRETE WITH THE C-34 DARK GREY COLOR MIX. 10. (E) ACCESSIBLE PATH OF TRAVEL FROM STALLS & PUBLIC WAY TO PRIMARY ENTRANCE.SEE CIVIL DRAWINGS. SLOPE NOT TO EXCEED 1:20 EXCEPT AT CURB RAMPS AND OTHERDEFINED RAMPS. CROSS SLOPE NOT TO EXCEED 1/4" PER FOOT. SEE GENERAL NOTES ONTHIS SHEET FOR ADDITIONAL DATA. STRIPE PAVING WITH WHITE PAINT AT ALL DRIVEWAYCROSSINGS. 11. (E) ACCESSIBLE PRIMARY ENTRANCE / EXIT. PROVIDE 5' MIN. DEEP LEVEL CONCRETELANDING WITH MAX. CROSS SLOPES NOT EXCEEDING 1/4" PER FOOT. PROVIDEACCESSIBILITY SIGNAGE, NO SMOKING SIGNAGE,AND EXIT SIGN ON INTERIOR PER SHEET T24-3. 12. (E) CONCRETE TILT-UP MANUFACTURING/OFFICE / WAREHOUSE FACILITY. 13. (E) ON-SITE FIRE HYDRANT. PROVIDE GUARD POSTS PER FIRE DEPARTMENTSTANDARDS. 14. PROPERTY LINE. 15. LANDSCAPE CONTROLLER. SEE LANDSCAPE DRAWINGS. 16. (E) 3000 PSI CONCRETE SITE PAVING OVER COMPACTED SUBGRADE PER GEOTECH REPORT.SEE CIVIL DRAWINGS FOR THICKNESS. SEE STRUCTURAL DRAWINGS FOR REINFORCING. INTRUCK YARD. PROVIDE CONTROL / CONSTRUCTION JOINTS PER STRUCTURAL DRAWINGS.PROVIDE MEDIUM BROOM FINISH. SEE CIVIL DRAWINGS FOR ADDITIONAL DATA. CONFIRMSUB-GRADE COMPACTION REQUIREMENTS WITH SOILS REPORT. PROVIDE REINFORCING INFORKLIFT RAMP SLABS PER FOUNDATION PLAN NOTES. 17. (E) INTERIOR ELECTRICAL SWITCHGEAR. SEE ELECTRICAL DRAWINGS. 18. (E) TRANSFORMER AND VAULT. SEE ELECTRICAL DRAWINGS FOR IMPROVEMENTS.PROXIMITY OF VAULT TO BUILDING SHALL BE GOVERNED BY STRUCTURAL FOOTINGDETAILS. PROVIDE BOLLARDS PER POWER COMPANY REQUIREMENTS -SEE ELECTRICALDWGS. 19. UNLESS SHOWN OTHERWISE, ALL EXIT DOORS SHALL HAVE A MINIMUM 5'-0" SQ. CLEARAND LEVEL CONCRETE LANDING W/ MAX. PER DETAIL 14/AD-1. CROSS SLOPES NOTEXCEEDING 1/4" PER FOOT. TYPICAL U.N.O. WHERE LANDINGS REQUIRE MORE THAN ONESTEP, PROVIDE STEEL HANDRAILS 20. (E) GRADE LEVEL LOADING DOOR. 21. (E) DOCK HIGH TRUCK LOADING DOOR. 22. (E) 8' HIGH ROLLING/SWING GATES AS SHOWN ON SITE PLAN. ALL SITE GATESWILL HAVE KNOX BOXES AND AND RAPID ENTRY SYSTEM TO ALLOW FOR FIRE DEPARTMENTACCESS. GATES SHALL PROVIDE 80% OPACITY. SUBMIT DETAILED SHOP DRAWINGS ANDCALCULATIONS FOR APPROVAL. PROVIDE CONDUIT FOR FUTURE GATE MOTORS ANDCOMMUNICATIONS. 23. (E) TYPICAL 8" DIA. (U.N.O.) CONCRETE FILLED GUARD POST PAINTED SAFETY YELLOWWHERE SHOWN. 24. (E) 12'-0" HIGH MIN. (AS MEASURED FROM INSIDE THE TRUCK YARD) PAINTED CONCRETESCREEN WALL. PROVIDE WATERPROOFING PER SPECS WHERE LANDSCAPED GRADE ON ONESIDE OF WALL IS ABOVE FINISH GRADE ON TO OTHER SIDE OF WALL. 25. (E)INTERIOR ROOF DRAIN AND/OR OVERFLOW DRAIN TO EXIT BUILDING THROUGH TILT-UPWALL OR RAMP PANEL. DRAIN PIPES TO EXTEND TO FACE OF CURB OR CONNECT WITHON-SITE STORM DRAIN SYSTEM. SEE CIVIL DRAWINGS. 26. (E) ONE HOUR RATED FIRE PUMP ROOM WITH FIRE DEPARTMENT ACCESS FROM EXTERIOR.PROVIDE SIGNAGE ON EXTERIOR DOOR. SEE FLOOR PLAN. 27. (E) TYPICAL STANDARD PARKING STALL 9' X 20' (OR 9' X 17' + 3' OVERHANG). 28. (E) BOLT DOWN RIBBON WAVE STYLE GALVANIZED BIKE RACK BY PATTERSON WILLIAMS.USE 5 BIKE CAPACITY 1602-05G . 29. (E) SANITARY SEWER LINE -SEE CIVIL DRAWINGS FOR FINAL LOCATIONS. 30. (E) DOMESTIC WATER LINE -SEE CIVIL DRAWINGS FOR FINAL LOCATIONS. 31. (E) TWO COMPARTMENT TRASH ENCLOSURE: MIN. 6' HIGH PAINTED CONCRETE WALLS W/PAINTED SOLID METAL GATES. PROVIDE 6"H (MIN.) X 6"W CONCRETE CURB AT INTERIORPERIMETER OF ENCLOSURE WITH EMBEDDED L3”X 3”X 1/4”GALVANIZED STEEL ANGLE &1/2”ROUND X 6”J-BOLTS @ 4'-0”ON CENTER MAX. PROVIDE CONCRETE SLAB AND APRONPER TRUCKING APRON REQUIREMENTS. ONE COMPARTMENT DESIGNATED FOR RECYCLABLEMATERIALS INCLUDING PLASTICS, METALS, PAPER, GLASS & CARDBOARD. 32. (E) 'CV' DESIGNATES A PARKING STALL MARKED AS "CLEAN AIR / VANPOOL / EV" VEHICLEPARKING. 33. (E) WATER QUALITY AND DETENTION BASIN . AT BASINS 4 & 5 PROVIDE A 5' MIN.SURROUNDING FENCE WITH MAINTENANCE ACCESS GATES. COORDINATE FINAL GATE ANDFENCE LOCATIONS WITH CIVIL DRAWINGS. 34. (E) ON SITE LIGHTING -POLE MOUNTED FIXTURES ON SACKED & PATCHED CONCRETEBASE. LIGHTING DESIGNED TO NOT CREATE GLARE INTO ADJACENT PROPERTIES ANDSTREETS. SEE ELECTRICAL DRAWINGS FOR FINAL LOCATIONS AND PHOTOMETRIC STUDY. 35. (E) ACCESSIBLE PATH SIGNAGE. 36.(E) ELECTRIC VEHICLE CAR CHARGING STATION TO SERVE TWO STALLS. 37. (E) PARKING LOT. 38. (E) 8'-0" TUBULAR STEEL PICKET FENCE. 39. (E) 36" MIN. DEPTH TRUNCATED DOME DETECTABLE WARNING SURFACE 40. PRIVATE STREET WITH ACCESSIBLE PATH SIDEWALKS & CURB CUTS AND ASIGNALIZED INTERSECTION AT LOWER AZUSA ROAD. SEE CIVIL DRAWINGS. 41. (E) STORM DRAIN AND EASEMENT. PROTECT IN PLACE. SEE CIVIL DRAWINGS. 42. (E) CMU SCREEN WALL. PROTECT IN PLACE. 43. (E) SEWER PUMP STATION. SEE CIVIL DRAWINGS. 44. (E) EMERGENCY GENERATOR FOR SEWER PUMP STATION. SEE ELECTRICAL DRAWINGS. 45. (E) 25' HIGH ILLUMINATED FLAGPOLE 46. (E) 12' SQ. CONCRETE PAVED LUNCH PATIO AREA: MIN. 4.5" THK. 2500 PSI WITH #3 BARS @18" O.C. EA. WAY OVER 95% COMPACTED 12" SUBGRADE. PROVIDE CONTROL /CONSTRUCTION JOINTS @ MAX. 5'-0" O.C. FINISH: #5 TOP-CAST WASH FINISHED CONCRETEWITH THE C-34 DARK GREY COLOR MIX. 47. (E) NO SMOKING WITHING 15' OF THE BUILDING SIGNAGE. 48. (E) AC UNITS. 49. (E) NEW TRUCK RAMP 50. (E) LEVEL LOADING DOOR FOR FINISH FLOOR GRADE LEVEL ACCESS. 51. (N) PROPOSED NEW CANOPY. 52. (E) ADA RAMP 53. (E) EQUIPMENT CANOPY 54. PROPOSED AREA OF WORK KEYNOTES:00 CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 3/ 3 / 2 0 2 5 8: 1 9 : 0 1 A M 3/3/2025 8:19:01 AM A8-1.0 SI T E P L A N 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1257-21 GL E N A I R L O G I S T I C S - BL D G 1 10 / 2 8 / 2 1 Au t h o r Ch e c k e r 1" = 30'-0"1 PROPOSED SITE PLAN - PHASE VIII UP UP G F E D C B A 1 1 2 2 3 3 4 5 6 7 8 9 10 11 12 13 F.6 3.52.5 E.9 F.4 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 60 ' - 0 " 61' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"52' - 0"59' - 0" 640' - 0" NORTH (E) ROOF ACCESS LADDER (E) EQUIPMENT CANOPY (E) CANOPY "A" (E) CANOPY "B" (E) CANOPY "D" AREA OF WORK WORK BENCH INTEGRATED LIGHING 96"X30" TYP. SEE TABLE 96"X30" TYP. SEE WORK BENCH ENG. 96"X30" TYP. SEE WORK BENCH 96"x30" TYP. SEE WORK BENCH 96"x30" TYP. SEE TABLE 96"X30" TYP. SEE EXISTING 14' - 3"8' - 0"9' - 5"10' - 8"9' - 0"15' - 7" TY P . 3' - 6 " 9' - 6" 9' - 7" 8' - 4" TY P . 6' - 8 1 / 2 " 6' - 7 " 7' - 6 1 / 2 " 24 ' - 0 " 6' - 1 0 " 6' - 8 " 11 ' - 1 1 1 / 2 " 6' - 2 1 / 2 " 7' - 6 " 6' - 8 1 / 2 " 7' - 0 " 6' - 8 1 / 2 " 7' - 0 " 6' - 5 1 / 2 " 6' - 6 1 / 8 " 6' - 8 1 / 2 " 7' - 6 " /3 A8-2.1/3 A8-2.1 /1 A8-2.1 /5 A8-2.1 /7 A8-2.1 /7 A8-2.1 TY P . 6' - 8 1 / 2 " 6' - 1 0 " 6' - 1 0 " 47 ' - 6 1 / 2 " 25 ' - 7 1 / 2 " TY P . 3' - 6 " CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 3/ 3 / 2 0 2 5 8: 1 9 : 3 6 A M 3/3/2025 8:19:36 AM A8-2.0 OV E R A L L G R O U N D L E V E L P L A N 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1257-21 GL E N A I R L O G I S T I C S - BL D G 1 11 / 0 3 / 2 1 Au t h o r Ch e c k e r 1" = 20'-0"1 OVERALL GROUND LEVEL PLAN - PHASE VIII 2' - 6 " 8' - 0" HEIGHT 32" HEIGHT 29" 2' - 6 " 8' - 0" 2' - 6 " 8' - 0" HEIGHT 32" 2' - 6 " 8' - 0" HEIGHT 34" 1/2" = 1'-0"1 WORK BENCH INTEGRATED LIGHING 96"X30" TYP. CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . B y Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 3/ 3 / 2 0 2 5 8: 1 9 : 4 0 A M 3/3/2025 8:19:40 AM A8-2.1 FU R N I T U R E E N L A R G E D P L A N S 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 1257-21 GL E N A I R L O G I S T I C S - BL D G 1 11 / 2 1 / 2 4 Au t h o r Ch e c k e r 2 3D View - WORK BENCH INTEGRATED LIGHING 96"X30" TYP. 1/2" = 1'-0"3 TABLE 96"X30" 4 3D View - TABLE 96"X30" 1/2" = 1'-0"5 WORK BENCH ENG. 96"X30" 6 3D View - WORK BENCH ENG. 96"X30" 1/2" = 1'-0"7 WORK BENCH 96"x30" 8 3D View - WORK BENCH 96"x30" GENERAL NOTES DIVISION OF WORK NOTE: INSULATION IS NOT REQUIRED FOR NON-FRAME DEMISING WALLS. NOTE: INSULATION IS NOT REQUIRED FOR NON-FRAME DEMISING WALLS. ≥ • • • ≥ • • • • • ≥ • • • • ≥ • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • “” G F E D C B A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 F.6 3.52.5 E.9 F.4 AREA OF WORK SH E E T I N D E X , M A N D A T O R Y N O T E S , & K E Y P L A N 8M0.0 CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 1 IS S U E D F O R P L A N C H E C K S U B M I T T A L LL 01 / 2 1 / 2 5 1 LL CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 1 IS S U E D F O R P L A N C H E C K S U B M I T T A L LL 01 / 2 1 / 2 5 1 LL EXHAUST FAN SCHEDULE EQ U I P ' T S C H D ' L N O T E S & D E T A I L S 8M1.0 CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 1 IS S U E D F O R P L A N C H E C K S U B M I T T A L LL 01 / 2 1 / 2 5 1 LL G F E D C B A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 F.6 3.52.5 E.9 F.4 6711 6712 6713 6714 6716 6717 6802 6803 6719 6804680568276800 6799 6798 6797 6824 6825 6826 6847 6848 6850 6849 68386837 6836 6835 6853 68466845 6843 6844 5794 5793 57915792 5790578957885787 5773 5774 5775 5776 5779 5778 5777 5781 5782 5785 5786 5550 6831 6832 6833 68346829 6842 5800 6461 5549 5809 5802 5803 5808 58055804 5806 5807 5765 5766 5767 5768 5769 5770 6474 6475 6476 6477 6478 6479 5759 5760 5761 5762 5763 5764 5759 5760 5761 5762 5763 5764 5755 5754 5753 5752 5751 5750 5749 5756 5757 5758 5799 6851 8M2.0 OV E R A L L H V A C F L O O R P L A N 1" = 20'-0"1 OVERALL HVAC PLAN - PHASE IX TRUE NORTH PROJECT NORTH CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 1 IS S U E D F O R P L A N C H E C K S U B M I T T A L LL 01 / 2 1 / 2 5 1 LL B C D E 54123 8M3.0 PA R T I A L H V A C F L O O R P L A N 3/32" = 1'-0"2 PARTIAL HVAC PLAN - PHASE IX TRUE NORTH PROJECT NORTH CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 1 IS S U E D F O R P L A N C H E C K S U B M I T T A L LL 01 / 2 1 / 2 5 1 LL DRAWING KEY NOTES G F E D C B A 1 1 2 2 3 3 4 4 5 6 7 8 9 10 11 12 13 F.6 3.52.5 E.9 F.4 NORTH 8M4.0 OV E R A L L H V A C R O O R P L A N 1" = 20'-0"1 OVERALL HVAC PLAN - PHASE IX TRUE NORTH PROJECT NORTH CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 1 IS S U E D F O R P L A N C H E C K S U B M I T T A L LL 01 / 2 1 / 2 5 1 LL 8M5.0 T- 2 4 C O M P L I A N C E E N E R G Y F O R M S CH E C K E D DR A W N FO R C O N S T R . DA T E O F I S S U E Da t e No . By Re v i s i o n s PROJECT NO. SHEET NO. PR O J E C T PRINT DATE & TIME 12 3 3 9 L O W E R A Z U S A R O A D AR C A D I A , C A 9 1 0 0 6 GL E N A I R L O G I S T I C S - B L D G 1 IS S U E D F O R P L A N C H E C K S U B M I T T A L LL 01 / 2 1 / 2 5 1 LL