Loading...
HomeMy WebLinkAbout400 S Baldwin AVe - 2025 - Dave & Busters kitchen remodelDAVE AND BUSTER'S STORE #34 400 South Baldwin Avenue Arcadia, CA 91007 LOCATION INFO. SHEET TITLE SHEET NO. NO. REVISION NOTES DATE TRU BUILD SURVEYS AS - BUILT SURVEY FIRM SCALE APPROVED BY DRAWN BY DATE PROJECT NO. TB 34 10.15.2024 BAP AMD DAVACO A CRANE COMPANY 4050 Valley View Lane | Suite150 | Irving, TX 75038 tel (214) 373-4700 | toll free (877) 732-8226 PERMIT SET SUBMIT 10/15/2024 COVER SHEET G0.0 NOT TO SCALE GENERAL NOTES DRAWING LIST PE R M I T S E T S U B M I T T A L 1 0 - 1 5 - 2 0 2 4 RE V 1 1 - 2 1 - 2 0 2 5 GENERAL G0.0 Cover Sheet G0.1 Code Analysis and Egress Plan ARCHITECTURAL A1.0 Demolition Plan A2.0 Depictive Floor Plan ELECTRICAL E0.0 Electrical Legend and Specs E1.0 Electrical Power Plan E2.0 Electrical Riser and Panels PLUMBING MP.1 Plumbing Specifications P1.0 Plumbing Plans FOOD SERVICE EQUIPMENT K1 Index Sheet K2 Kitchen Equipment, Schedule & Elevations Plan K5 Kitchen Electrical/Pos, Schedules & Elevations Plan K8 Kitchen Plumbing & Gas, Schedules & Elevations Plan K13 Kitchen Critical, Schedules & Elevations Plan 1. IN ALL INSTANCES, "OWNER" REFERS TO DAVE & BUSTERS. "LANDLORD" REFERS TO RELATED. "CONTRACTOR" REFERS TO D&B CONTRACTOR. 2. ALL MATERIALS AND LABOR FOR ALL WORK NOTED OR DEPICTED IN THE CONTRUCTION DOCUMENTS SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. 3. THE CONTRACTOR IS INFORMED THAT THIS PROJECT IS A FIT OUT AND RENOVATION OF AN EXISTING FACILITY. CONTRACTOR IS RESPONSIBLE FOR REVIEWING ALL OF THE CONSTRUCTION DOCUMENTS AND OBSERVING EXISTING CONDITIONS AT THE PRE-BID MEETING. 4. CONTRACTOR'S BASE BID SHALL INCLUDE ALL WORK REQUIRED TO ACHIEVE DESIGN INTENT. CONTRACTOR SHALL SUBMIT REQUEST FOR INFORMATION (RFI) DURING BID PROCESS FOR ANY CONCERNS WITH RECONCILING EXISTING CONDITIONS TO ACHIEVE DESIGN INTENT. 5. IN THE EVEN OF CONFLICTS OF INFORMATION ON THE CONSTRUCTION DOCUMENTS, THE MORE DETAILED AND STRICTEST INTERPRETATION SHALL GOVERN, DURING BIDDING CONTRACTOR SHALL SUBMIT REQUEST FOR INFORMATION (RFI) FOR ANY REQUESTS AND/OR CLARIFICATIONS. 6. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ARCHITECT PRIOR TO COMMENCING THE WORK. 7. THE CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES AND SHALL REPORT ANY DEFECTS, DISCREPANCIES, PROBLEMS OR UNCERTAINTIES TO THE ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK AFFECTED. 8. ALL WORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL CODES, ORDINANCES AND ANY APPLICABLE AMENDMENTS. 9. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY BRACING AS REQUIRED TO ENSURE THE VERTICAL AND LATERAL STABILITY OF THE ENTIRE STRUCTURE OR A PORTION THEREOF DURING CONSTRUCTION. 10. THE CONTRACTOR SHALL PROVIDE OPENINGS AND CORES, NOT SPECIFICALLY SHOWN ON THE DRAWING, AS REQUIRED FOR MECHANICAL AND ELECTRICAL EQUIPMENT, VENTS, DUCTS, AND TYPICAL DETAILS. 11. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES, INCLUDING ADVISING ALL TRADES OF FEATURES OF CONSTRUCTION AND PROVIDING BLOCKS, HOLES, DEPRESSIONS, ETC, AS REQUIRED, FOR A COMPLETE JOB. REFER TO ALL DRAWINGS FOR SLAB DEPRESSIONS, SLOPES, CURBS, DRAINS, OPENINGS, ETC. 12. THE CONTRACTOR IS TO BUILD AND MAINTAIN CONSTRUCTION BARRICADES (ALL NECESSARY LIGHTS, SIGNS, ETC.) FOR THE PROTECTION OF THE PUBLIC, AS PER LOCAL ORDINANCES AND LANDLORD REQUIREMENTS. 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OR REPLACEMENT FOR ANY DAMAGE CAUSE BY THEM OR THEIR SUBCONTRACTORS TO EXISTING WORK IN PLACE. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MISCELLANEOUS PERMITS, FEES, AND INSPECTIONS AS MAY BE REQUIRED FOR COMPLETION OF THE JOB AS PER ALL GOVERNING AGENCIES. 15. NO STRUCTURAL CHANGES FROM THE APPROVED PLANS SHALL BE MADE IN THE FIELD WITHOUT PRIOR WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER. IF CHANGES ARE MADE WITHOUT WRITTEN APPROVAL, SUCH CHANGES SHALL BE THE LEGAL AND FINANCIAL RESPONSIBILITY OF THE CONTRACTOR TO REPLACE OR REPAIR AS DIRECTED BY THE STRUCTURAL ENGINEER. 16. ALL CONTRACTORS SHALL PROVIDE LIABILITY INSURANCE AND WORKERS COMPENSATION BENEFITS IN ACCORDANCE WITH STATE LAW FOR ALL WORKERS AND AGENTS WHO WILL BE ON THE SITE AT ANY TIME. OWNERS' CONTRACTOR TO PROVIDE INSURANCE PER CONTRACT AND INSURANCE CERTIFICATE WITH COVERAGE'S AND ADDITIONAL INSURANCE AS REQUIRED BY LANDLORD PRIOR TO CONSTRUCTION START. 17. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL BE FULLY ACQUAINTED WITH SCOPE OF THE WORK TO BE PERFORMED AND SHALL INSPECT SITE CONDITIONS PRIOR TO BID SUBMITTAL. BID SHALL INCLUDE ALL LABOR AND MATERIALS REQUIRED TO COMPLETE THE SCOPE OF WORK. 18. IT IS UNDERSTOOD THAT THE OWNER MAY BE PURCHASING AND/OR INSTALLING MATERIALS, EQUIPMENT, AND FURNISHINGS UNDER SEPARATE CONTRACTS. THE CONTRACTOR AND HIS SUBCONTRACTORS SHALL COOPERATE WITH THE OWNER TO ALLOW THE DELIVERY AND INSTALLATION OF SUCH MATERIALS, EQUIPMENT, AND FURNISHINGS BY OTHER CONTRACTORS AND SUPPLIERS WHICH MAY COMMENCE PRIOR TO FINAL ACCEPTANCE OF THE REMODELED SPACE BY THE OWNER SO AS TO ASSURE THE OWNER OF THE EARLIEST POSSIBLE COMPLETION DATE. 19. NO CHANGE ORDERS WILL BE ALLOWED FOR CLAIMS DUE TO UNFORESEEN OR UNANTICIPATED CONDITIONS WHICH COULD HAVE BEEN DISCOVERED BY THE BIDDING CONTRACTOR DURING INSPECTION OF THE SITE DURING THE BIDDING PERIOD AND PRIOR TO THE COMMENCEMENT OF THE WORK. 20. THESE DRAWINGS ARE NOT TO BE SCALED. IF REQUIRED DIMENSIONS FOR INFORMATION CANNOT BE FOUND WITHIN THE DRAWINGS OR SPECIFICATIONS, THE ARCHITECT SHALL BE REQUESTED TO INTERPRET THE DOCUMENT, WHICH SHALL BE FINAL AND BINDING. 21. ANY PURPOSED SUBSTITUTIONS SHALL BE SUBMITTED TO THE OWNER, LANDLORD AND THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO INCORPORATION INTO THE WORK. THE CONTRACTOR SHALL BE TOTALLY RESPONSIBLE FOR ANY CHANGES TO DETAILS OR CONDITIONS MADE NECESSARY BY ANY SUBSTITUTION. 22. CONTRACTOR TO PROVIDE AND INSTALL FIRE-STOPPING AT ALL PENETRATIONS AND ALL RATED ASSEMBLIES PER DRAWINGS AND PER CODE. 23. IF CONTRACTOR PROCEEDS WITH ANY WORK ON WHICH THERE IS DISCREPANCY IN INFORMATION PRIOR TO SEEKING AND RECEIVING CLARIFICATION FROM THE OWNER OR ARCHITECT, IT IS THE CONTRACTOR'S RISK. OWNER RETAINS RIGHT FOR REMEDY AT NO ADDITIONAL COST. CONTACT INFO DAVE AND BUSTER'S DAVE AND BUSTER'S 122 SOUTH BELTLINE ROAD SUITE 500 COPPELL, TEXAS 75019 PHONE: 616.499.2250 CONTACT: ADAM DALY GENERAL CONTRACTOR DAVACO 4050 VALLEY VIEW LANE SUITE 150 IRVING, TX 75039 PHONE: 214.373.4700 PHONE (TOLL FREE): 877.732.8226 ARCHITECT AGI 15 WEST SEVENTH ST. COVINGTON, KY 41011 PHONE: 859.261.5400 CONTACT: TIM SEAMAN - tseaman@agi-us.com KITCHEN RENOVATION CONSTRUCTION DOCUMENT SET LOCATION/SITE DESCRIPTION DAVE AND BUSTER'S STORE #: 34 400 SOUTH BALDWIN AVENUE ARCADIA, CA 91007 CONSTRUCTION TYPE: III-A OCCUPANCY TYPE: A-2 SCOPE OF WORK: MINOR KITCHEN RENOVATION INCLUDING REPLACEMENT OF EQUIPMENT, CUT AND CAP OF PLUMBING AND ELECTRICAL AS PER PLANS. NO CHANGES TO PARTITIONS OR EXHAUST. NO CHANGE TO USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION. TOTAL AFFECTED AREA: 772 SQFT. 1 CONS DOCUMENTS 1/21/2025 GENERAL DEMO NOTES 1. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS AND SCOPE OF DEMOLITION TO ACHIEVE AND ACCOMMODATE THE CONSTRUCTION AND INSTALLATION OF THE COMPLETE AND FINAL DESIGN CONDITION, WHETHER OR NOT EACH ELEMENT OF DEMOLITION IS SPECIFICALLY NOTED OR GRAPHICALLY DEPICTED. 2. CONTRACTOR IS TO VERIFY AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND DESIGN INTENT AND SUBMIT REQUEST FOR INFORMATION (BID CLARIFICATION) FOR ANY UNCERTAIN SCOPE PRIOR TO SUBMISSION OF BIDS. HAZMAT NOTE IN THE EVENT OF HAZARDOUS MATERIALS OR OTHER TOXIC SUBSTANCE EXPOSURE OR THE SUBSTANCE EXPOSURE OR THE SUBSTANTIAL RISK THEREOF, CLIENT WILL HAVE THE DUTY TO INFORM ARCHITECT OF SUCH RISKS KNOWN OR REASONABLY KNOWABLE TO CLIENT. IF HAZARDOUS MATERIALS OR ANY OTHER TOXIC SUBSTANCE, OR RISKS TO THE EXPOSURE THEREOF IS DISCOVERED BY ARCHITECT DURING WORK ON THE PROJECT, ARCHITECT SHALL, IN ITS SOLE DISCRETION, HAVE THE RIGHT TO SUSPEND WORK ON THE PROJECT. CLIENT SHALL HAVE THE DUTY PROMPTLY TO RETAIN A QUALIFIED EXPERT SAFELY TO RENDER OR SUPERVISE THE REMOVAL OF SUCH HAZARDOUS MATERIALS. CLIENT SHALL INDEMNIFY AND HOLD ARCHITECT, ITS AFFILIATES AND SUB-CONTRACTORS, AND THEIR OFFICERS, AGENTS AND EMPLOYEES HARMLESS FROM ANY AND ALL LIABILITY ON PART OF OR DAMAGE TO SUCH ENTITIES OR PERSONS, INCLUDING THE COST OF LEGAL FEES AND EXPENSES, AS SUCH FEES AND EXPENSES ARE INCURRED, WHICH MAY RESULT FROM HAZARDOUS MATERIALS EXPOSURE ON THE PROJECT. APPLICABLE CODES BUILDING CALIFORNIA EXISTING BUILDING CODE 2022 (IEBC 2021 AMENDED) CALIFORNIA BUILDING CODE 2022 (IBC 2021 AMENDED) MECHANICAL CALIFORNIA MECHANICAL CODE 2022 (IMC 2021 AMENDED) ELECTRICAL CALIFORNIA ELECTRICAL CODE 2022 (NFPA 70, 2020 AMENDED) PLUMBING CALIFORNIA PLUMBING CODE 2022 (UPC 2021 AMENDED) FIRE CODE CALIFORNIA FIRE CODE 2022 (IFC 2021 AMENDED) ENERGY CALIFORNIA ENERGY CODE 2022 (CEC 2022) - ISSUED FOR APPROVAL/CONSTRUCTION - ISSUED FOR REFERENCE ONLY SITE LOCATION PROJECT SITE 1 KCL-INS: ("MTR-SLIMJ " " V 2 D " ) W=0.0000 - X=11.0000 - Y = 2 0 . 0 0 0 0 - Z = 3 0 . 0 0 0 0 KCL-INS: ("MTR-SLIMJ" "V2D")W=0.0000 - X=11.0000 - Y=20.000 0 - Z = 3 0 . 0 0 0 0 KCL-INS: ("MTR-SLIMJ" "V2D")W=0.0000 - X=11.0000 - Y=20.000 0 - Z = 3 0 . 0 0 0 0 KCL-INS: ("MTR-SLIMJ" "V 2 D " ) W=0.0000 - X=11.0000 - Y= 2 0 . 0 0 0 0 - Z = 3 0 . 0 0 0 0 KCL-INS: ("MTR-SLIMJ" "V2 D " ) W=0.0000 - X=11.0000 - Y= 2 0 . 0 0 0 0 - Z = 3 0 . 0 0 0 0 TRAVEL DISTANCE 149'-4" TRA V E L D I S T A N C E 2 1 4 ' - 7 " DAVE AND BUSTER'S STORE #34 400 South Baldwin Avenue Arcadia, CA 91007 LOCATION INFO. SHEET TITLE SHEET NO. NO. REVISION NOTES DATE TRU BUILD SURVEYS AS - BUILT SURVEY FIRM SCALE APPROVED BY DRAWN BY DATE PROJECT NO. TB 34 10.15.2024 BAP AMD DAVACO A CRANE COMPANY 4050 Valley View Lane | Suite150 | Irving, TX 75038 tel (214) 373-4700 | toll free (877) 732-8226 PERMIT SET SUBMIT 10/15/2024 CODE ANALYSIS AND EGRESS PLAN G0.1 NOT TO SCALE 1 EGRESS PLAN NOT TO SCALE PLUMBING FIXTURE COUNT - NO CHANGE CODE INFORMATION & EGRESS PLAN LEGEND STAIR (.3) /DOOR (.2)EXITING PATH LEGEND DOOR 36" MAX EXPT EXPECTED LOAD MAX. LOAD EXIT WIDTH PROVIDED EGRESS LOADS MARKER DESIGN TRAVEL DISTANCE SECOND MEANS OF EGRESS PATH SPRINKLER REQUIREMENTS: FIRE ALARM REQUIREMENTS: SECTION 1017 TABLE 1017.2 EGRESS TABLE 1006.2.1 COMMON PATH OF EGRESS TRAVEL SEATING AREA ALL OTHER AREAS EXIT ACCESS TRAVEL DISTANCE EXIT ACCESS TRAVEL DISTANCE A-2/A-3 ASSEMBLY EXIT ACCESS TRAVEL DISTANCE PROVIDED 250' (WITH SPRINKLER SYSTEM) 150' SECTION 903 TOTAL OCCUPANT LOAD - 1,868 (NO CHANGE) GENERAL CONSTRUCTION DATA SECTION 302 NO CHANGE < 250' SECTION 602 TABLE 803.13 BUILDING USE AND OCCUPANCY GROUP CONSTRUCTION CLASSIFICATION (FOLLOW SHELL BUILDING) EXIT PASSAGEWAYS AND EXIT ENCLOSURES CORRIDORS ROOMS AND ENCLOSED SPACES AUTOMATIC SPRINKLER SYSTEM BUILDING HEIGHT AND AREA ALLOWABLE HEIGHT AND BUILDING AREASTABLE 506.2 AUTOMATIC SPRINKLER - EXISTING ACTUAL AREA STORIES ABOVE GRADE PLANE FEET ABOVE GRADE PLANE A-2, A-3 ASSEMBLY III-A INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY B B C FULLY SPRINKLERED 903.2.1.2, GROUP A-2 ALLOWED PROVIDED EXISTING 2 EXISTING EXISTING BUILDING FIRE RESISTANCE RATINGS TABLE 601 BEARING WALLS INTERIOR EXTERIOR NON-BEARING WALLS AND PARTITIONS EXTERIOR NON-BEARING WALLS AND PARTITIONS INTERIOR FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOIST ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOIST 2 NO CHANGE FIRE RESISTANT RATING REQUIREMENTS FOR BUILDING ELEMENTS STRUCTURAL FRAME REQUIRED 0 HOURS 0 HOURS 2 HOURS 0 HOURS 0 HOURS 0 HOURS 0 HOURS TABLE 504.3/504.4 TABLE 504.3/504.4 EXISTING FIRE/LIFE SAFETY NOTES 1. ILLUMINATED EXIT SIGNS SHALL BE PROVIDED THROUGHOUT THE BUILDING. ALL EXIT SIGNS SHALL HAVE BATTERY BACKUP. 2. THIS BUILDING SHALL BE PROVIDED WITH APPROVED BATTERY POWERED EMERGENCY LIGHTING TO ILLUMINATE ALL REQUIRED MEANS OF EGRESS. 3. DOORS SHALL BE ARRANGED TO BE OPENED READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE EGRESS SIDE. 4. EMERGENCY LIGHTING UNITYS SHALL BE WIRED INTO THE NORMAL LIGHTING CIRCUIT AND ARRANGED AS TO PROVIDE THE REQUIRED ILLUMINATION AUTOMATICALLY IN THE EVENT OF ANY INTERRUPTION OF NORMAL LIGHTING SUCH AS ANY FAILURE OF PUBLIC UTILITY OR OUTSIDE ELECTRICAL POWER SUPPLY, OPENING OF A CIRCUIT BREAKER OR FUSE, OR ANY MANUAL ACTS INCLUDING ACCIDENTAL OPENING OF SWITCH CONTROLLING NORMAL LIGHTING FACILITIES. 5. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM THE INSIDE OF THE CLOSETS. 6. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY. THE OPENING DEVICE SHALL BE READILY ACCESSIBLE TO ANYONE OUTSIDE THE DOOR. 7. THE ELEVATION OF THE FLOOR SURFACES ON BOTH SIDES OF A DOOR SHALL NOT VARY BY MORE THAN 1/2". THE ELEVATION SHALL BE MAINTAINED ON BOTH SIDES OF THE DOORWAY FOR A DISTANCE NOT LESS THAN THE WIDTH OF THE WIDEST LEAF. THRESHOLDS AT THE DOORWAYS SHALL NOT EXCEED 1/2" IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES IN EXCESS OF 1/4" SHALL BE BEVELED WITH A SLOPE OF NOT STEEPER THAN 1 IN 2. 8. A LATCH OR OTHER FASTENING DEVICE ON A DOOR SHALL BE PROVIDED WITH A RELEASING DEVICE HAVING AN OBVIOUS METHOD OF OPERATION AND THAT IS READILY OPERATED UNDER ALL LIGHTING CONDITIONS. THE RELEASING MECHANISM FOR ANY LATCH SHALL BE NOT LESS THAN 34", AND NOT MORE THAN 48" ABOVE FINISH FLOOR. DOORS SHALL BE OPERABLE WITH NOT MORE THAN ONE RELEASING OPERATION. 9. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED, INSPECTED, AND MAINTAINED IN ACCORDANCE WITH NFPA STANDARDS OR LOCAL FIRE DEPARTMENT REQUIREMENTS GOVERNING PORTABLE FIRE EXTINGUISHERS. SCOPE OF WORK LOCATION EXIT EXIT SIGN EXIT SIGN EXIT COMPLIANCE NO CHANGE OF USE & NO CHANGE OF EXIT PATH OR TRAVEL DISTANCE EXIT 75' MAX. SECTION 1006.1 MIN. NUMBER OF EXITS REQUIRED 4 REQUIRED (4 PROVIDED) FIRE SAFETY PERMITTING UNDER SEPARATE PERMIT 1 PERMIT NOTIFICATION 1/21/2025 1 PREP LINE COOK LINE EXPO LINE PERIMETER OF SCOPE OF WORK: OCCUPANCY AND EGRESS UNCHANGED DAVE AND BUSTER'S STORE #34 400 South Baldwin Avenue Arcadia, CA 91007 LOCATION INFO. SHEET TITLE SHEET NO. NO. REVISION NOTES DATE TRU BUILD SURVEYS AS - BUILT SURVEY FIRM SCALE APPROVED BY DRAWN BY DATE PROJECT NO. TB 34 10.15.2024 BAP AMD DAVACO A CRANE COMPANY 4050 Valley View Lane | Suite150 | Irving, TX 75038 tel (214) 373-4700 | toll free (877) 732-8226 PERMIT SET SUBMIT 10/15/2024 DEMOLITION PLAN A1.0 3/8" = 1'-0" 1. EXPO LINE EXISTING EQUIPMENT TO REMAIN. 2. PREP LINE EXISTING EQUIPMENT TO REMAIN. 3. EXISTING FLOOR DRAINS AND FLOOR SINKS TO REMAIN. REPAIR OR REPLACE AS REQUIRED. THOROUGHLY CLEAN EACH FIXTURES AND PROVIDE NEW GRATE TO MATCH EXISTING SIZE AND STYLE. 4. EXISTING CONCRETE CURBS TO BE REMOVED IN THEIR ENTIRETY. GC TO PATCH, REPAIR AND FILL ALL CONCRETE SURFACES WHERE CONCRETE WAS REMOVED. GC TO PREPARE FOR NEW EPOXY COATING TO MATCH EXISTING. 5. PREP WALL SURFACES FOR ANY NEW APPLICATIONS WHERE NECESSARY. KEY NOTES 1 1 DEMO - FLOOR PLAN 3/8" = 1'-0" GENERAL NOTES 1. CONTRACTOR IS TO COORDINATE REQUIRED LOCATION FOR ALL IN-WALL BLOCKING. CONTRACTOR IS TO PROVIDE FIRE TREATED IN-WALL BLOCKING, BACKING AND SUBSTRATES FOR MILLWORK, SHELVING, PANELS, SIGNS, TV'S, ETC. REFER TO K-SHEETS FOR MORE INFORMATION. 2. ALL DIMENSIONS ARE NOMINAL AND ARE FROM FACE OF SUBSTRATE, UNLESS NOTED OTHERWISE. 3. CONTRACTOR TO VERIFY EXISTING SITE CONDITIONS BEFORE ANY WORK IS TO BEGIN, NOTIFY ARCHITECT OF DISCREPANCIES. THE DRAWINGS SHALL BE READ IN CONJUNCTION WITH STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND OTHER CONSULTANT DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS OR SKETCHES AS MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. ANY DISCREPANCIES SHALL BE REFERRED TO THE SUPERINTENDENT AND ARCHITECT BEFORE PROCEEDING WITH ANY WORK. 4. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL GOVERNING STATE AND LOCAL CODES AND ORDINANCES. 5. ALL EQUIPMENT ROOMS TO BE VENTILATED AS REQUIRED BY CODE. SEE MECHANICAL SHEETS FILED UNDER SEPARATE APPLICATION. 6. ALL NEW PARTITIONS WITH SINKS AND/OR "WET EQUIPMENT" TO HAVE 5/8" WATER RESISTANT GYPSUM BOARD UNLESS NOTED OTHERWISE, WITH 5/8" CEMENT BOARD BASE TO 12" A.F.F. DEMOLITION NOTES 1. SEE MEP & STRUCTURAL DRAWINGS FOR ADDITIONAL DEMOLITION SCOPE AND NOTES. 2. CONTRACTOR TO VERIFY EXTENT OF ALL REMOVALS AND DIMENSIONS IN THE FIELD. GC TO NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO COMMENCEMENT OF WORK. 3. CUT & CAP EXISTING ABANDONED SANITARY & VENT LINES AT SLAB & FILL SLAB OPENING. COORDINATE WITH PLUMBING DRAWINGS. 4. ALL EXISTING STRUCTURE (BEAMS, GIRDERS, COLUMNS, DECKING, ETC.) TO REMAIN, UON. 5. PROTECT ALL SURFACES, SUBSTRATES AND CONSTRUCTION WHICH IS NOT SCHEDULED FOR DEMOLITION. 1. WHEREVER PATCHING OR REPAIRS TO EXISTING FLOOR ARE NECESSARY AS A RESULT OF WORK DONE GC TO PROVIDE THE FOLLOWING: - CONTINUOUS WATERPROOFING 12" UP THE WALL AND 12" OUT ONTO THE FLOOR WHERE APPLICABLE. - AN APPLIED EPOXY SYSTEM WITH INTEGRAL COVE BASE AND J-BEAD MOLDING TO RECEIVE WALL FINISH. - ALL MATERIALS TO MATCH EXISTING AND BE INSTALLED PER MANUFACTURERS INSTRUCTIONS TO ENSURE COMPLETELY WATERPROOF SURFACE. 6 2 1 2 3 3 4 4 4 4 5 5 5 6 6 6 3 PREP LINE COOK LINE EXPO LINE 14 K2 12 K2 12 K2 14 K2 KCL-INS: ("MTR-SLIMJ" "V2D " ) W=0.0000 - X=11.0000 - Y=2 0 . 0 0 0 0 - Z = 3 0 . 0 0 0 0 KCL-INS: ("MTR-SLIMJ" "V2D")W=0.0000 - X=11.0000 - Y=20.0000 - Z = 3 0 . 0 0 0 0 KCL-INS: ("MTR-SLIMJ" "V2D")W=0.0000 - X=11.0000 - Y=20.0000 - Z = 3 0 . 0 0 0 0 KCL-INS: ("MTR-SLIMJ" "V2D " ) W=0.0000 - X=11.0000 - Y=20 . 0 0 0 0 - Z = 3 0 . 0 0 0 0 KCL-INS: ("MTR-SLIMJ" " V 2 D " ) W=0.0000 - X=11.0000 - Y = 2 0 . 0 0 0 0 - Z = 3 0 . 0 0 0 0 DAVE AND BUSTER'S STORE #34 400 South Baldwin Avenue Arcadia, CA 91007 LOCATION INFO. SHEET TITLE SHEET NO. NO. REVISION NOTES DATE TRU BUILD SURVEYS AS - BUILT SURVEY FIRM SCALE APPROVED BY DRAWN BY DATE PROJECT NO. TB 34 10.15.2024 BAP AMD DAVACO A CRANE COMPANY 4050 Valley View Lane | Suite150 | Irving, TX 75038 tel (214) 373-4700 | toll free (877) 732-8226 PERMIT SET SUBMIT 10/15/2024 DEPICTIVE FLOOR PLAN A2.0 3/8" = 1'-0" 1. NO CHANGE TO EXISTING EXHAUST OR FIRE SUPPRESSION WILL BE REQUIRED TO ACCOMMODATE THE KITCHEN EQUIPMENT BEING REPLACED. 2. NO CHANGE TO EXISTING OCCUPANCY OR EGRESS WILL BE REQUIRED TO ACCOMMODATE THE KITCHEN EQUIPMENT BEING REPLACED. 3. EXISTING HAND SINK TO REMAIN. KEY NOTES 1 1 DEPICTIVE FLOOR PLAN 3/8" = 1'-0" GENERAL NOTES 1. CONTRACTOR IS TO COORDINATE REQUIRED LOCATION FOR ALL IN-WALL BLOCKING. CONTRACTOR IS TO PROVIDE FIRE TREATED IN-WALL BLOCKING, BACKING AND SUBSTRATES FOR MILLWORK, SHELVING, PANELS, SIGNS, TV'S, ETC. REFER TO K-SHEETS FOR MORE INFORMATION. 2. ALL DIMENSIONS ARE NOMINAL AND ARE FROM FACE OF SUBSTRATE, UNLESS NOTED OTHERWISE. 3. CONTRACTOR TO VERIFY EXISTING SITE CONDITIONS BEFORE ANY WORK IS TO BEGIN, NOTIFY ARCHITECT OF DISCREPANCIES. THE DRAWINGS SHALL BE READ IN CONJUNCTION WITH STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND OTHER CONSULTANT DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS OR SKETCHES AS MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. ANY DISCREPANCIES SHALL BE REFERRED TO THE SUPERINTENDENT AND ARCHITECT BEFORE PROCEEDING WITH ANY WORK. 4. ALL WORK TO BE DONE IN ACCORDANCE WITH ALL GOVERNING STATE AND LOCAL CODES AND ORDINANCES. 5. ALL EQUIPMENT ROOMS TO BE VENTILATED AS REQUIRED BY CODE. SEE MECHANICAL SHEETS FILED UNDER SEPARATE APPLICATION. 6. ALL NEW PARTITIONS WITH SINKS AND/OR "WET EQUIPMENT" TO HAVE 5/8" WATER RESISTANT GYPSUM BOARD UNLESS NOTED OTHERWISE, WITH 5/8" CEMENT BOARD BASE TO 12" A.F.F. 2 2 2 1 1 3 3 1 TC OS OS SOS SWP ST SM SD S4 T X A, AMPS AMPERES A/C AIR CONDITIONER AC ALTERNATING CURRENT AF AMPERE FRAME AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE AL ALUMINUM AWG AMERICAN WIRE GAUGE BC BARE COPPER BKBD BACKBOARD CONDUIT CB CIRCUIT BREAKER CKT CIRCUIT CU COPPER DIST DISTRIBUTION DN DOWN DP DISTRIBUTION PANEL DWG DRAWING ELR END-OF-LINE RESISTOR EWC ELECTRIC WATER COOLER <E> EXISTING <EX> EXISTING FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FLA FULL LOAD AMPERES GND GROUND GALV GALVANIZED GRS GALVANIZED RIGID STEEL GFCI GROUND FAULT HD HEAT DETECTOR HP HORSEPOWER IMC INTERMEDIATE METAL CONDUIT ISC INTERRUPTING SHORT CIRCUIT IG ISOLATED GROUND INST INSTANTANEOUS JB JUNCTION BOX KAIC KILO (THOUSAND) AMPERES KCMIL KILO (THOUSAND) KV KILO (THOUSAND) VOLTS KVA KILO (THOUSAND) KW KILO (THOUSAND) WATTS KWH KILO (THOUSAND) WATT-HOURS MCB MAIN CIRCUIT BREAKER MCM THOUSAND CIRCULAR MILS MCCB MOLDED CASE MLO MAIN LUGS ONLY NEUTRAL NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN, NTS NOT TO SCALE PNL PANELBOARD PVC POLYVINYL CHLORIDE RGS RIGID GALVANIZED SCA SHORT CIRCUIT SWBD SWITCHBOARD TBD TO BE DETERMINED TCP TEMPERATURE CONTROL TD TIME DELAY TEL TELEPHONE TYP TYPICAL UG UNDERGROUND UON UNLESS OTHERWISE UNDERGROUND PULLBOX VOLTS VA VOLT-AMPERES VFD VARIABLE WH WATER HEATER WP WEATHERPROOF WT WATERTIGHT XFMR TRANSFORMER ELECTRICAL LEGEND T X SURGE SUPPRESSION C (NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS AND ARE USED AS APPLICABLE TO THIS PROJECT) V N EC EMPTY CONDUIT FAA FIRE ALARM ANNUNCIATOR NEC NATIONAL ELECTRICAL RMC RIGID METALLIC RNC RIGID NON-METALLIC FREQUENCY DRIVE INTERRUPTING CURRENT LED TROFFER, TYPE AS NOTED SWGR SWITCHGEAR RMS ROOT-MEAN-SQUARE NESC NATIONAL ELECTRICAL ANSI AMERICAN NATIONAL STANDARDS INSTITUTE EB ENCASED BURIAL EEW ENERGIZED ELECTRICAL WORK EGC EQUIPMENT GROUNDING <ER> EXISTING TO REMAIN CONDUCTOR PANEL TVSS TRANSIENT VOLTAGE STEEL CONDUIT CONDUIT (GALVANIZED) SAFETY CODE VOLT-AMPERES LIQUID-TIGHT FLEXIBLE CIRCULAR MILS INTERRUPTING CAPACITY CIRCUIT INTERRUPTER AVAILABLE CONDUIT NUMBER CODE S3 PC S X SSS SS SS3 3 GFI GROUND FAULT INTERRUPTER RECESSED CAN FIXTURE, TYPE AS NOTED LED STRIP FIXTURE WALL MOUNTED FIXTURE, TYPE AS NOTED TRACK LIGHT FIXTURE, TYPE AS NOTED EMERGENCY LIGHT EXIT/EMERGENCY LIGHT COMBINATION CEILING MOUNTED EXIT SIGN WALL MOUNTED EXIT SIGN SINGLE POLE SWITCH, 44" AFF THREE WAY SWITCH, 44" AFF FOUR WAY SWITCH, 44" AFF WEATHER PROOF SWITCH, 44" AFF MOTOR RATED SWITCH, 44" AFF OR AS NOTED COMBINATION SWITCH AND OCCUPANCY SENSOR, 44" AFF DIGITAL TIMER SWITCH, 44" AFF CEILING MOUNTED OCCUPANCY SENSOR WALL MOUNTED OCCUPANCY SENSOR, 44" AFF TIME CLOCK PHOTO CELL PROVIDE WITH EMERGENCY BALLAST LED TROFFER, TYPE AS NOTED LED TROFFER, TYPE AS NOTED PROVIDE WITH EMERGENCY BALLAST LED TROFFER, TYPE AS NOTED PROVIDE WITH EMERGENCY BALLAST RECESSED CAN FIXTURE, TYPE AS NOTED FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF TWO SINGLE POLE SWITCHES GANGED TOGETHER FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF TWO THREE WAY SWITCHES GANGED TOGETHER LIGHTING CONTACTORLC S S EC TO PROVIDE BLACK SPEAKER 8" CONE SPEAKER IN CEILING EC TO PROVIDE BLACK SPEAKER 8" CONE SPEAKER IN WALL TELEVISION/CABLE OUTLET DOOR HOLD-OPEN DEVICE TRANSFORMER, SEE ONE LINE SMOKE DETECTOR HORN DUCT MOUNTED SMOKE DETECTOR WPWP 18" AFF OR AS NOTED, NEMA 5-20R DUPLEX RECEPTACLE 18" AFF OR AS NOTED, NEMA 5-20R WEATHER PROOF DUPLEX RECEPTACLE ABOVE COUNTER OR AS NOTED, NEMA 5-20R DUPLEX RECEPTACLE 18" AFF OR AS NOTED, NEMA 5-20R QUAD RECEPTACLE IG 18" AFF OR AS NOTED, NEMA 5-20R DUPLEX RECEPTACLE J JJJ WALL / CEILING MOUNTED JUNCTION BOX 60/3/1 F 60/3/3R/40 60/3/1 F 60/3/3R/40 RATING/POLES/NEMA RATING UNFUSED DISCONNECT SWITCH RATING/POLES/NEMA RATING/FUSE SIZE FUSED DISCONNECT SWITCH TVTV SINGLE GANG PLASTER RING, 3/4" C ABOVE CEILING TELEPHONE OUTLET, PROVIDE 4" BOX SINGLE GANG PLASTER RING, 3/4" C ABOVE CEILING DATA OUTLET, PROVIDE 4" BOX FLUSH IN FLOOR, 3/4" C ABOVE CEILING TELEPHONE OUTLET, PROVIDE 4" BOX FLUSH IN FLOOR, 3/4" C ABOVE CEILING DATA OUTLET, PROVIDE 4" BOX 18" AFF OR AS NOTED, SEE SCHEDULE SPECIAL PURPOSE RECEPTACLE CCTVCCTV S S CEILING / WALL MOUNT FIRE ALARM STROBE, MIN 75 CANDELA SPEAKER STROBE HEAT DETECTOR TAMPER SWITCH H TS FLOW SWITCHFS PULL STATION MOTOR GROUND M TVSS TRANSFORMER UTILITY GRADE METER TRANSIENT VOLTAGE SURGE SUPPRESSOR 4'X8' UNLESS NOTED OTHERWISE PLYWOOD EQUIPMENT BACKBOARD RACEWAY CONCEALED IN WALL OR ABOVE CEILING RACEWAY EXPOSED BELOW SLAB OR GRADE, OR UNDER RAISED ACCESS FLOOR RACEWAY CONCEALED IN FLOOR SLAB, BELOW SLAB OR GRADE STUB UP DENOTES CONDUIT TURNING DOWN IN PLAN VIEW DENOTES CONDUIT TURNING UP IN PLAN VIEW ABBREVIATIONS VOLUME CONTROLV PENDANT FIXTURE, TYPE AS NOTED PROVIDE WITH EMERGENCY BALLAST PENDANT FIXTURE, TYPE AS NOTED 44" AFF WALL BOX DIMMER 1000W UNLESS NOTED DIFFERENTLY 44" AFF THREE SINGLE POLE SWITCHES GANGED TOGETHER CLOSED CIRCUIT TELEVISION CAMERA ELECTRICAL SPECIFICATIONS A. DEFINITIONS: 1. "PROVIDE": FURNISH AND INSTALL, COMPLETE AND READY FOR OPERATION. 2. "INSTALL": RECEIVE, MOUNT, AND CONNECT, COMPLETE AND READY FOR OPERATION. 3. "FURNISH": SUPPLY, DELIVER TO JOB SITE, PROTECT AND STORE. B. WORK INCLUDED: PROVIDE ALL LABOR, TOOLS, MATERIAL, EXCAVATION, BACKFILL, CUTTING, PATCHING, TESTING, ADJUSTING, AND TRADE COORDINATION REQUIRED FOR A COMPLETE AND FULLY OPERATIONAL INSTALLATION, AS DESCRIBED ON THE DRAWINGS OR IN THE SPECIFICATIONS. C. CODES, RULES, AND REGULATIONS: COMPLY WITH ALL CODES ENFORCED BY THE LOCAL INSPECTION AUTHORITY, THE 2020 EDITION OF THE NATIONAL ELECTRICAL CODE (N.E.C) BEING ENFORCED FOR THIS PROJECT BY THE LOCAL INSPECTION AUTHORITY, ALL APPLICABLE LAWS AND ORDINANCE, NFPA FIRE CODES, STANDARD BUILDING CODE. GIVE ALL NECESSARY NOTICES, OBTAIN ALL REQUIRED PERMITS, AND PAY ALL INSPECTION AND OTHER FEES REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER THE WORK. D.MATERIALS: ALL MATERIAL SHALL BE NEW, AND SHALL COMPLY WITH THE INDICATED STANDARDS. ALL MATERIAL SHALL BE U/L LABELED OR U/L LISTED. ALL MATERIAL SHALL BE OF A SUITABLE TYPE AND RATING FOR THE INTENDED USE, AND SHALL BE INSTALLED IN CONFORMANCE WITH THE INSTRUCTIONS AND RECOMMENDATIONS OF THE MANUFACTURER. E.DRAWINGS 1. THE DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL OF THE REQUIRED DETAILS OF THE WORK. ALL MATERIALS CUSTOMARILY CONSIDERED TO BE A PART OF THE ELECTRICAL WORK AND REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION SHALL BE PROVIDED WITHOUT ADDITIONAL COST TO THE OWNER. 2. THE CONTRACTOR SHALL REFER ALSO TO THE ARCHITECTURAL DRAWINGS AND TO THE DRAWINGS OF ALL OTHER TRADES TO COORDINATE THE ELECTRICAL INSTALLATION. WHERE ELECTRICAL EQUIPMENT IS SHOWN ON ARCHITECTURAL DRAWINGS OR DETAILS, THE EQUIPMENT SHALL BE INSTALLED AS SHOWN ON THE ARCHITECTURAL DRAWINGS. 3. EQUIPMENT OF OTHER TRADES IS SHOWN SCHEMATICALLY ON THE ELECTRICAL DRAWINGS. THE CONTRACTOR SHALL EXAMINE THE DRAWINGS OF THE TRADE PROVIDING THE EQUIPMENT BEFORE ROUGHING IN THE CONNECTIONS FOR IT. THE CONTRACTOR SHALL CONNECT THE EQUIPMENT WHERE ACTUALLY INSTALLED, INCLUDING WIRING THROUGH ANY LINE VOLTAGE CONTROLLERS, WITHOUT ANY ADDITIONAL COST TO THE OWNER. 4. PRIOR TO ROUGHING IN CIRCUITS FOR EQUIPMENT FURNISHED BY OTHER TRADES, AND PRIOR TO RELEASING FOR MANUFACTURE PANELBOARDS, STARTERS OR MOTOR CONTROL CENTERS FEEDING SUCH EQUIPMENT, THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL PROVISIONS BEING PLANNED WITH THE TRADE PROVIDING THE EQUIPMENT AND SUBMIT ANY CONFLICTS IN WRITING TO THE ARCHITECT. 5. THE ARCHITECT MAY DIRECT THE RELOCATION OF ANY ELECTRICAL OUTLET, FIXTURE, OR OTHER EQUIPMENT TO A LOCATION WITHIN 10 FEET OF THE LOCATION SHOWN ON THE DRAWINGS AT NO ADDITIONAL COST TO THE OWNER PROVIDED SUCH RELOCATION IS DIRECTED PRIOR TO THE INSTALLATION OF THE OUTLET, FIXTURE OR EQUIPMENT BEING RELOCATED. F. SUBMITTAL DOCUMENTS: PRODUCT DATA AND SHOP DRAWINGS SHALL BE SUBMITTED IN SIX COPIES TO THE ARCHITECT FOR REVIEW PRIOR TO THE RELEASE OF THE MATERIAL FOR MANUFACTURE. REVIEW OF SUBMITTALS BY THE ARCHITECT WILL BE ONLY FOR GENERAL CONFORMANCE WITH THE DRAWINGS AND SPECIFICATIONS. REVIEW WILL BE MADE ONLY OF INFORMATION CLEARLY AND SPECIFICALLY INDICATED IN THE SUBMITTAL, AND DOES NOT IMPLY THE ACCEPTABILITY OF DETAILS WHICH ARE NOT SO DESCRIBED IN THE SUBMITTAL. REVIEW OF THE SUBMITTAL DOCUMENTS BY THE ARCHITECT DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO COMPLY WITH ALL REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. SUBMITTAL IS REQUIRED FOR PANELBOARDS AND LOADCENTERS, LIGHT FIXTURES, WIRING DEVICES, FIRE ALARM DEVICES, AND SURFACE ALUMINUM RACEWAY. G.AS-BUILT DRAWINGS: AS-BUILT DRAWINGS SHALL BE MAINTAINED AT THE JOBSITE, AND SHALL BE AVAILABLE FOR REVIEW DURING CONSTRUCTION. AS-BUILT DRAWINGS SHALL BE KEPT CURRENT DURING THE COURSE OF CONSTRUCTION OF THE WORK. SUBMIT AS-BUILT DRAWINGS TO THE ARCHITECT AT THE COMPLETION OF THE PROJECT. H. TESTING: TEST ALL PARTS OF THE WORK TO VERIFY COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS. VERIFY TIGHTNESS OF ALL MECHANICAL AND ELECTRICAL CONNECTIONS. VERIFY INTEGRITY OF ALL WIRING SYSTEMS TO ASSURE CONTINUITY, ABSENCE OF UNINTENTIONAL GROUNDS, AND INTEGRITY OF REQUIRED GROUNDS. I. CHANGE REQUEST (CHANGE ORDER) APPROVAL: CHANGE REQUESTS WILL NOT BE CONSIDERED UNLESS THE CONTRACTOR'S DETAILED LABOR AND MATERIAL ESTIMATE DESCRIBING THE CHANGE IS SUBMITTED TO THE ARCHITECT ALONG WITH THE CHANGE REQUEST, WITH MATERIAL PRICES AND LABOR UNITS ASSIGNED TO EACH LINE ITEM OF THE ESTIMATE. MATERIAL PRICES SHALL BE THE ACTUAL PRICE PAID BY THE CONTRACTOR FOR MATERIAL PURCHASED OR THE ACTUAL PRICE QUOTED TO THE CONTRACTOR BY THE MATERIAL VENDOR PROPOSED BY THE CONTRACTOR. J.COORDINATION WITH THE WORK OF OTHERS: COORDINATE WITH EACH TRADE FURNISHING EQUIPMENT REQUIRING ELECTRICAL SERVICE TO INSURE THAT THE CHARACTERISTICS SHOWN ON THE DRAWINGS FOR THE CIRCUIT SERVING THE EQUIPMENT ARE COMPATIBLE WITH THE REQUIREMENTS OF THE EQUIPMENT BEING FURNISHED. CIRCUIT BREAKERS, FUSES, DISCONNECT SWITCHES AND ASSOCIATED BRANCH CIRCUITS SHOWN ON THE DRAWINGS TO FEED HVAC EQUIPMENT, KITCHEN EQUIPMENT, ELEVATOR MOTORS, AND OTHER EQUIPMENT HAVE BEEN SELECTED BASED UPON THE CHARACTERISTICS OF EQUIPMENT BY ONE MANUFACTURER AND MAY NOT BE CORRECT FOR THE EQUIPMENT BEING PROVIDED BY THE CONTRACTOR. THE CONTRACTOR SHALL DETERMINE THE OPERATING CHARACTERISTICS OF THE EQUIPMENT ACTUALLY BEING PROVIDED AND SHALL PROVIDE AT NO ADDITIONAL COST TO THE OWNER CIRCUIT BREAKERS, FUSES, DISCONNECT SWITCHES AND BRANCH CIRCUITS AS REQUIRED BY THAT EQUIPMENT. K.EXISTING WORK: THE EXISTING ELECTRICAL INSTALLATION SHALL REMAIN AS-IS AND IN OPERATION EXCEPT WHERE OTHERWISE REQUIRED. GIVE WRITTEN NOTICE OF ANY UNFORESEEN EXISTING CONDITIONS WHICH MAY AFFECT THE WORK. WORK INVOLVING EXISTING SYSTEMS OR EXISTING SPACES SHALL BE ACCOMPLISHED WITH MINIMUM INCONVENIENCE TO THE OWNER, AND SHALL BE DONE IN A MANNER AND TIME APPROVED BY THE OWNER. ANY INTERRUPTIONS SHALL BE DURING TIMES DESIGNATED BY THE OWNER. L. DEMOLITION: IN THE AREA SHOWN ON THE ARCHITECTURAL DRAWINGS TO BE DEMOLISHED REMOVE ALL EXISTING CONDUITS, CONDUCTORS, BOXES, FIXTURES, SERVICE ENTRANCE CONDUCTORS, DISTRIBUTION EQUIPMENT, AND ALL OTHER ELECTRICAL EQUIPMENT NOT SHOWN TO REMAIN. UNLESS OTHERWISE INDICATED, MATERIAL BEING REMOVED INCLUDING WIRE, CONDUIT, AND HANGING MATERIALS BEING REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES. EQUIPMENT NOTED TO REMAIN THE PROPERTY OF THE OWNER SHALL BE STORED ON SITE AS DIRECTED BY THE ARCHITECT. COORDINATE WITH OTHER TRADES AND DISCONNECT MOTORS, HEATERS, OR OTHER EQUIPMENT AS REQUIRED FOR THE DEMOLITION OF OTHER TRADES WORK. CUT OFF ALL IN FLOOR CONDUITS, GRIND SMOOTH WITH FLOOR AND PREPARE FOR PATCHING BY OTHERS. REMOVE CONDUCTORS AND DEVICES FROM WALL AND CEILING OUTLETS AND PREPARE OUTLET FOR PATCHING BY OTHERS. CONTRACTOR SHALL DENOTE ALL DEMOLISHED CIRCUITS ON EXISTING PANEL DIRECTORIES AND NOTE ALL SPARE BREAKERS. 3. ALL PENETRATIONS OF FIRE RATED WALLS, SLABS, PARTITIONS, AND CEILINGS SHALL BE FIREPROOFED WITH A U.L. LISTED SYSTEM THAT WILL MAINTAIN THE ORIGINAL FIRE RATING OF THE PENETRATED STRUCTURE. ALL FIREPROOFING MATERIALS APPLIED AT ANY ONE PENETRATION SHALL BE THE PRODUCT OF ONE MANUFACTURER AND SHALL BE APPLIED AS DESCRIBED BY THE U.L. FIREPROOFING SYSTEM BEING CONSTRUCTED. FIREPROOFING OF SLEEVES, CABLE TRAYS, TROUGHS, AND NIPPLES TO BE USED FOR LOW VOLTAGE CABLES SHALL BE INDEFINITELY NON-HARDENING AND REMOVABLE WITH COMMON HAND TOOLS. 4. BACKBOARDS SHALL BE 8 FT. HIGH BY LENGTH SHOWN ON THE DRAWINGS AND SHALL BE U/L LABELED FIRE TREATED PLYWOOD. 5. PROVIDE ALL POWER WIRING AND CONNECTIONS FOR ALL ELECTRICALLY OPERATED EQUIPMENT. POWER WIRING INCLUDES WIRING THROUGH ANY LINE VOLTAGE CONTROL DEVICES, SUCH AS THERMOSTATS AND MANUAL STARTERS. INSTALL ALL STARTERS AND CONTACTORS EXCEPT THOSE FURNISHED AS AN INTEGRAL PART OF THE EQUIPMENT. 6. CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT NOT INSTALLED IN A PLENUM SPACE SHALL BE MADE WITH A SHORT LENGTH OF LIQUIDTIGHT FLEXIBLE CONDUIT, MINIMUM 18", INSTALLED IN A MANNER TO PERMIT MOVEMENT OF EQUIPMENT. 7. PERFORM ALL EXCAVATING, BACKFILLING, CUTTING AND REPAIRING REQUIRED FOR INSTALLATION OF ELECTRICAL WORK. 8. CONTRACTOR SHALL X-RAY FLOOR SLABS PRIOR TO ALL CORE DRILLINGS. N.CONDUIT: FEEDERS AND BRANCH CIRCUIT HOME RUNS SHALL BE CONSTRUCTED OF EMT WITH ALL STEEL SET-SCREW FITTINGS. CONNECTORS SHALL BE INSULATED THROAT TYPE. PROVIDE METALLIC BUSHINGS WITH PLASTIC INSERTS FOR 3" OR LARGER. CONDUITS FEEDING OR CONNECTING TO EQUIPMENT PROVIDED BY OTHER TRADES SHALL NOT BE INSTALLED UNTIL SUCH EQUIPMENT IS INSTALLED OR UNTIL SPECIFIC ROUGH-IN INSTRUCTIONS ARE PROVIDED BY THE TRADE PROVIDING THE EQUIPMENT. UNLESS OTHERWISE INDICATED, CONDUITS SHALL BE CONCEALED. RACEWAYS INSTALLED IN OR UNDER SLABS, ON GRADE, OR AS EXTERIOR DUCT BANKS SHALL BE PVC COATED RMC. RUN EXPOSED CONDUITS PARALLEL OR PERPENDICULAR TO STRUCTURAL ELEMENTS. TWO OR MORE RACEWAYS RUN TOGETHER SHALL BE INSTALLED ON GANG TRAPEZE TYPE HANGERS. SUCH RACEWAYS ASSEMBLIES SHALL BE RUN PARALLEL OR PERPENDICULAR TO STRUCTURAL ELEMENTS. CONDUITS EMBEDDED IN SLABS SHALL HAVE A MINIMUM OF 1" COVER OF CONCRETE ON ALL SIDES. OUTSIDE DIAMETER OF CONDUIT SHALL NOT EXCEED 1/3 OF THE SLAB THICKNESS, AND SHALL NOT BE LARGER THAN 1 1/4". PROVIDE 0.25" NYLON PULL TAPE IN ALL EMPTY CONDUITS. BRANCH CIRCUITS MAY UTILIZE TYPE MC ARMORED CABLE ASSEMBLY WITH COPPER CONDUCTORS AND FULL SIZE EQUIPMENT GROUNDING CONDUCTORS FOR INDIVIDUAL DROPS TO DEVICES. TYPE MC CABLE SHALL BE SUPPORTED A 48" INTERVALS AND SHALL NOT LAY ON THE CEILING GRID OR INTERFERE WITH THE REMOVAL OF CEILING SIZE EQUIPMENT GROUNDING CONDUCTORS. O.CONDUCTORS: ALL BUILDING WIRE SHALL BE 600 VOLT RATED THHN OR THWN COPPER, STRANDED FOR SIZES $8AWG AND LARGER, SOLID FOR SIZES 10 AND SMALLER UNLESS APPLIED FOR CONTROL. ALL BUILDING WIRE AND SPECIAL CABLES FOR SYSTEMS SHALL BE INSTALLED IN A RACEWAY. ALL WIRE AND CABLE SHALL BE DELIVERED TO THE JOBSITE IN ORIGINAL UNBROKEN PACKAGES, CARTONS OR REELS, WITH THE MANUFACTURERS NAME, UL LABEL, AND CHARACTERISTICS OF THE PRODUCT PLAINLY VISIBLE. ALL WIRE AND CABLE SHALL BE MANUFACTURED IN THE UNITED STATES OF AMERICA. WIRES SHALL BE COLOR CODED AS FOLLOWS (A,B,C,N,G): 120/208-BLACK, RED, BLUE, WHITE, GREEN; 480/277 - BROWN, ORANGE, YELLOW, GRAY, GREEN. SPLICES SHALL BE COMPRESSION TYPE. CONTROL CONDUCTORS SHALL BE TERMINATED WITH INSULATED CONNECTORS, T&B STAKON. 120 VOLT CIRCUITS WITH HOMERUN LENGTH OVER 100 FEET AND 277 VOLT CIRCUITS WITH A HOMERUN LENGTH OVER 200 FEET SHALL HAVE #10 MINIMUM HOMERUN CONDUCTORS. ALL THREE PHASE BRANCH CIRCUITS WITH A COMMON NEUTRAL SHALL HAVE #10 MINIMUM NEUTRAL. P.BOXES: OUTLET BOXES SHALL BE SHEET STEEL, MINIMUM 4" SQUARE, MINIMUM 1.5" DEEP, WITH PLASTER RING IN PLASTER OR BRICK CONSTRUCTION. OUTLETS BOXES IN POURED CONCRETE SHALL BE CONCRETE RINGS. MASONRY BOXES SHALL BE USED IN MASONRY OR TILE CONSTRUCTION. OUTLET BOXES FOR SURFACE ALUMINUM RACEWAY SHALL BE 4-11/16 WITH PLASTER RINGS ORIENTED HORIZONTALLY. BOXES SHALL BE SECURELY ANCHORED IN PLACE, AND SHALL BE SUPPORTED INDEPENDENT OF THE RACEWAY SYSTEM. PULL BOXES SHALL BE GALVANIZED SHEET STEEL, MINIMUM 12 GAUGE, WITH SCREW COVERS, AND WELDED CONSTRUCTION. WELDS SHALL BE COLD GALVANIZED. USING PERMANENT WATER PROOF WIDE BLACK MARKER, CLEARLY LABEL COVER OF ALL BRANCH CIRCUIT JUNCTION AND PULL BOXES WITH PANEL AND CIRCUIT NUMBER OF CIRCUITS CONTAINED IN OR PASSING THROUGH THE BOX. BRANCH CIRCUIT AND FEEDER JUNCTION AND PULL BOXES USED WITH EMERGENCY FEEDERS AND CIRCUITS SHALL BE PAINTED RED. PROVIDE ENGRAVED LAMINATED PLASTIC LABEL ON COVER OF EACH FEEDER PULL OR JUNCTION BOX INDICATING FEEDER DESIGNATION, SOURCE, LOAD, AND VOLTAGE. Q.WIRING DEVICES: SWITCHES FOR LIGHTING CIRCUITS SHALL BE 120/277 VOLT, 20 AMP, A.C. ONLY, QUIET TYPE, WITH GROUND BONDING SCREW, SPECIFICATION GRADE. MOMENTARY CONTACT SWITCHES SHALL BE SINGLE POLL DOUBLE THROW, CENTER OFF GE #5935 OR EQUAL. DUPLEX RECEPTACLES SHALL BE 15 AMP HUBBELL 5262 OR EQUAL. DEDICATED DUPLEX RECEPTACLES SHALL BE 20AMP HUBBELL IG5362 OR EQUAL. SPECIAL RECEPTACLES SHALL BE OF SIMILAR CONSTRUCTION. FACE PLATES SHALL BE SMOOTH NYLON OR THERMOSET PLASTIC. ADJACENT OUTLETS SHALL BE INSTALLED IN MULTI-GANG BOXES WITH A SINGLE MULTI-GANG FACE PLATE. RECEPTACLES CONNECTED TO AN EMERGENCY CIRCUIT SHALL BE RED. COORDINATE COLOR OF DEVICES AND FACEPLATE WITH ARCHITECT. R.GROUNDING: ALL FEEDERS AND BRANCH CIRCUITS SHALL BE PROVIDED WITH INSULATED GREEN EQUIPMENT GROUNDING CONDUCTOR. S.LIGHTING: SPARE FLUORESCENT LAMPS SHALL MATCH BUILDING STANDARD UNLESS NOTED OTHERWISE. INCANDESCENT LAMPS SHALL BE 130VOLT. NEW BALLASTS SHALL BE SOILD STATE ELECTRONIC. EXIT FIXTURES SHALL MATCH BUILDING STANDARD. FIXTURE LOCATIONS SHALL BE AS SHOWN ON THE REFLECTED CEILING PLAN. PROVIDE LAY-IN FIXTURES WITH TWO REMOVABLE CLIPS ATTACHING FIXTURE TO CEILING GRID. FLANGED FIXTURES SHOWN TO BE INSTALLED IN CONTINUOUS ROWS SHALL NOT HAVE INTERMEDIATE FLANGES. ALL PENDANT FIXTURES SHALL BE MOUNTED TO STRUCTURE. SEISMIC SUPPORT WIRES AND/OR COMPRESSION STRUTS FOR LAY-IN FIXTURES SHALL BE SUBJECT TO LOCAL AHJ LATEST REQUIREMENTS. T.PANELBOARDS: DEAD FRONT PANEL CONSTRUCTION WITH SEPARATELY MOUNTED INTERIOR TRIM. MAIN AND BRANCH DEVICES SHALL BE BOLT-ON. MULTI-POLE BREAKERS SHALL BE COMMON TRIP. WIDTH SHALL NOT EXCEED 22" FOR PANELBOARD AND ENCLOSURE SHALL MATCH BUILDING STANDARD. PROVIDE GROUND BUS IN PANELBOARD AND PROVIDE DEVICE MOUNTING HARDWARE WHERE A SPACE IS SCHEDULED. PANEL AND OCPD SHORT CIRCUIT RATINGS SHALL BE AT LEAST 10% GREATER THAN AVAILABLE SHORT CIRCUIT CURRENT AT PANELBOARD. U.DRY-TYPE TRANSFORMERS: TRANSFORMERS SHALL BE DRY-TYPE, ENCLOSED, SELF-COOLED, VENTILATED TYPE, DEAD-FRONT DRIP PROOF. PRIMARY AND SECONDARY TAPS SHALL BE ACCESSIBLE FROM THE FRONT. TRANSFORMERS SHALL MEET OR EXCEED BUILDING STANDARD TRANSFORMERS SPECIFICATIONS. PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR IN THE PRIMARY FEED TO THE TRANSFORMER, SUPPLEMENTAL GROUND TO NEAREST ACCESSIBLE PRIMARY STRUCTURAL MEMBER OR EQUIPMENT ROOM GROUND BUS BAR. SIZE PER NEC AND RUN IN CONDUIT WITH BOND BUSHING AT EACH END. NEUTRAL AND GROUNDING CONDUCTOR SHALL BE BONDED TO ENCLOSURE. SHORT CIRCUIT AVAILABLE CURRENTXXXX LFMC METAL CONDUIT USB AFF AS NOTED, NEMA 5-20R W/ USB CHARGER WEATHER PROOF DUPLEX RECEPTACLE TYPE WSD OR EQUAL M. BASIC MATERIALS AND METHODS: 1. ALL WORK SHALL BE SUPPORTED FROM STRUCTURAL ELEMENTS OF THE BUILDING, EXCEPT CEILING MOUNTED EQUIPMENT SUCH AS LIGHT FIXTURES, DETECTORS, REMOTE LAMPS, ETC. CEILING MOUNTED EQUIPMENT SHALL BE SUPPORTED FROM CEILING STRUCTURAL MEMBERS, INDEPENDENT OF CEILING TILES. SIZE AND SPACING OF SUPPORTS SHALL BE DETERMINED BY THE LOAD TO BE SUPPORTED SUCH THAT THE WORKING LOAD OF SUPPORTS WILL NOT EXCEED A SAFETY FACTOR OF 4:1. PLASTIC ANCHORS ARE NOT ACCEPTABLE. ELECTRICAL WORK SHALL NOT BE SUPPORTED FROM PIPING, DUCTS, OR WORK OF OTHER TRADES. 2. PROVIDE ENGRAVED PLASTIC NAMEPLATES FOR ALL SWITCHBOARDS, PANELBOARDS, MOTOR CONTROL CENTERS, STARTERS, DISCONNECTS, PRIMARY SELECTOR SWITCHES, AND TRANSFORMERS. INDICATE EQUIPMENT NAME, CIRCUIT SOURCE AND NUMBER, CIRCUIT SIZE, AMPERE RATING, VOLTAGE AND PHASE. NAMEPLATES SHALL BE BLACK BACKGROUND LAMACOID PLASTIC WITH 0.25" WHITE LETTERS. E0.0 ELECTRICAL LEGEND AND SPECS BYREVISIONS DRAWN: CHECKED: DATE: SCALE: 54 S o u t h A v e n u e Ma r i e t t a , G A 3 0 0 6 0 40 0 - 8 0 0 - 7 9 8 8 in f o @ c o n v e r g e e n g i n e e r s . c o m DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A GUID O O AL RE Z REGI S TRE D E P R OF ESSIONALE N G IN E E R ELECT R I C A L A TATEOF I R NIA C F OL N S I A A F R R F R R ELECTRICAL POWER PLAN 1/4" = 1'-0" ELECTRICAL POS PLAN 1/4" = 1'-0" E7 2 B E7 0 . 2 KD S 5 4 A KD S 5 4 B GFCI NOTE: ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 50 AMPERES OR LESS, AND ALL RECEPTACLES SUPPLIED BY THREE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS IN KITCHENS AND FOOD PREP AREAS SHALL USE GFCI BREAKER TYPE. GFCI BREAKERS SHALL BE INSTALLED IN ACCORDANCE WITH 2020 NEC ARTICLE 210.8. ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 50 AMPERES OR LESS, AND ALL RECEPTACLES SUPPLIED BY THREE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS IN RESTROOMS, WITHIN 6 FEET FROM A SINK, OR ON EXTERIOR SHALL BE INSTALLED IN ACCORDANCE WITH 2020 NEC ARTICLE 210.8 AND BE READY ACCESSIBLE. FOR EQUIPMENT THAT WOULD HAVE TO BE MOVED TO RESET THE RECEPTACLE PER THE NEC DEFINITION. A GFCI BREAKER SHALL BE UTILIZED IN LIEU OF A RECEPTACLE. KITCHEN ELECTRICAL SCHEDULE ITEM #V/ɸ AMPS H.P.KW TYPE LOCATION A.F.F.NEMA REMARKS EDCO 120V/1 PH 15.0 EACH --D.C.O.WALL 48"5-20R CONVENIENCE OUTLET - (2) RIP'S E45 115V/1 PH 5.2 0.35 -D.C.O.WALL 24"5-15P UNDER COUNTER FREEZER - E.C. TO SUPPLY & INSTALL GFCI PROTECTED DUPLEX E49 115V/1 PH 4.7 0.25 -D.C.O.WALL 24"5-15P PIZZA STATION - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E49B 115V/1 PH 4.7 --D.C.O.WALL 24"5-15P SAUTE STATION - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E54 115V/1 PH 4.7 --D.C.O.WALL 24"5-15P BREADING STATION - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E55 120V/1 PH CONTROLS - 1.0, FILTER - 8.0 --QUAD WALL 24"5-20R FRYER ASSEMBLY w/FILTER - DEDICATED 20A CIRCUIT BREAKER E58 120V/1 PH .6 EACH --D.C.O.WALL 24"5-15P COUNTER TOP PLANCHA - (2) RIP'S E59 115V/1 PH 12.0 --D.C.O.WALL 24"5-15P SHORTY REFRIGERATOR - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E60 120V/1 PH 15.9 EACH - 1910 WATTS EACH D.C.O.WALL 48"5-20P FRY WARMING STATION - (2) RIP'S E64 115V/1 PH 2.9 --D.C.O.WALL 24"5-15P SHORTY REFRIGERATOR - E.C. TO SUPPLY & INSTALL GFCI PROTECTED DUPLEX E66 208V/1 PH 13.6 EACH - 1700 WATTS EACH S.P.O.WALL 72"6-20P MICROWAVE - (3) RIP'S E66A 208V/1 PH 13.6 -1700 WATTS S.P.O.WALL 72"6-20P MICROWAVE - REUSE EXISTING OUTLET E70.2 115V/1 PH 5.5 0.55 -D.C.O.WALL 72"5-15P REACH-IN FREEZER E71 115V/1 PH 4.2 0.22 -D.C.O.WALL 90"5-15P REACH-IN REFRIGERATOR - REUSE EXISTING OUTET E71A 115V/1 PH 4.2 0.22 -D.C.O.WALL 72"5-15P REACH-IN REFRIGERATOR E72A 115V/1 PH 4.7 --D.C.O.WALL 24"5-15P FRY REFRIGERATOR - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E72B 115V/1 PH 6.5 (2) 0.20 -D.C.O.WALL 24"5-15P DISH-UP REFRIGERATOR - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E72C 115V/1 PH 6.5 --D.C.O.WALL 24"5-15P PIZZA PREP REFRIGERATOR - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E73 120V/1 PH 3.3 -400 WATTS D.C.O.WALL 48"5-15P COUNTER TOP WARMER E74 120V/1 PH 15.0 -1800 WATTS D.C.O./ JBOX WALL 52"5-15P CONVEYOR TOASTER - REUSE EXISTING OUTLET E75 120V/1 PH 7.5 -900 WATTS D.C.O.WALL 24"5-15P WARMING DRAWER - NARROW 2-TIER E76 120V/1 PH 12.0 -1440 WATTS D.C.O.WALL 24"5-15P CVAP HOLDING DRAWER E125 208V/3 PH 30.0 EACH -9600 WATTS S.P.O.WALL 48"15-30P CONVECTION OVEN - (2) RIP'S - E.C. INSTALL 4S BOX E143 120V/1 PH 10.0 EACH - 1200 WATTS EACH D.C.O.WALL 48"5-15P HOT FOOD WELL - (2) RIP'S E143A 120V/1 PH 10.0 -1200 WATTS D.C.O.WALL 24"5-15P HOT FOOD WELL KITCHEN POS ELECTRICAL SCHEDULE ITEM #V/ɸ AMPS TYPE LOCATION A.F.F.REMARKS KDS54A 120V/ 1 PH 20.0 D.C.O.WALL 66"KDS SYSTEM - DEDICATED CIRCUIT - VERIFY REQUIREMENTS w/OWNER KDS54B DATA JBOX WALL 66"DATA/KDS CABLE - 2" x 4" EMPTY BOX w/CONDUIT TO 6" ABOVE CEILING LINE - VERIFY REQUIREMENTS w/OWNER KDS64A 120V/ 1 PH 20.0 D.C.O.WALL 72"KDS SYSTEM - REUSE EXISTING OUTLET KDS64B DATA JBOX WALL 72"DATA/KDS CABLE - REUSE EXISTING OUTLET KDS72C 120V/ 1 PH 20.0 EACH D.C.O.WALL 86"KDS SYSTEM - DEDICATED CIRCUIT - VERIFY REQUIREMENTS w/OWNER KDS72D DATA JBOX WALL 86"DATA/KDS CABLE - 2" x 4" EMPTY BOX w/CONDUIT TO 6" ABOVE CEILING LINE - VERIFY REQUIREMENTS w/OWNER KDS72E 120V/ 1 PH 20.0 EACH D.C.O.WALL VARIES KDS SYSTEM - (4) RIP'S - REUSE EXISTING OUTLET KDS72F DATA VARIES WALL VARIES DATA/KDS CABLE - (4) RIP'S - REUSE EXISTING OUTLET POWER NOTES: 1.COORDINATE DISCONNECTION OF POWER TO EQUIPMENT BEING DEMOLISHED/REMOVED/RELOCATED PRIOR TO START OF WORK. 2.FOR KITCHEN EQUIPMENT BEING REMOVED/REPLACE: REUSE EXISTING ELECTRICAL DEVICES AND CIRCUITRY IF IS IN GOOD WORKING CONDITION AND MEET REQUIREMENTS OF NEW/REPLACED KITCHEN EQUIPMENT. OTHERWISE, REMOVE DEVICES AND CAP AND ABANDON EXISTING WIRING, DISCONNECT FEEDER AT PANELBOARD, TURN OFF AND LABEL BREAKER AS "SPARE". 3.REFER TO KITCHEN ELECTRICAL EQUIPMENT FOR ROUGH-IN LOCATIONS AND ADDITIONAL REQUIREMENTS . 4.REFER TO ARCHITECTURAL FOR EXACT ELECTRICAL OUTLETS LOCATION OF KITCHEN ELECTRICAL EQUIPMENT. 5.PROPOSED GFCI BANK LOCATION AS PER GFCI NOTE ON THIS SHEET. ALL GFCI DEVICES SHALL BE ACCESSIBLE. COORDINATE FINAL LOCATION WITH KITCHEN EQUIPMENT. SEE DETAIL. 6.G.C SHALL PROVIDE LITTEL FUSE INDUSTRIAL SHOCK BLOCK GFCI CLASS A SB5000 OR SIMILAR TO ALL 208V SINGLE AND THREE PHASE EQUIPMENT WITHIN THE KITCHEN AREA. E7 6 ED C O E7 1 E6 6 E7 4 E6 0 E7 2 A E7 2 C E7 5 E1 4 3 E1 2 5 E1 2 5 E6 6 A E6 6 E4 9 GFCI BANK #1 DETAIL NTS GFCI BANK #2 DETAIL NTS KB-7 EDCO NOTE 5 NOTE 5 GFCI BANK #1 GFCI BANK #2 E71 E72B E74 E76 E60 E72A E72C E75 E143 E49 KDS KDSE58 E5 4 E1 4 3 A E5 5 E6 0 E4 5 E7 3 E5 8 E5 9 E5 8 E1 4 3 E4 9 B E6 6 E6 4 E7 1 A KD S 7 2 E KD S 7 2 F KD S 7 2 E KD S 7 2 F KD S 7 2 F KD S 7 2 E KD S 7 2 D KD S 7 2 C KD S 7 2 E KD S 7 2 F KD S 6 4 A KD S 6 4 B E54 E143A EDCO E55 E60 E45 E73 KB - 3 1 , 3 3 , 3 5 NO T E 6 KB - 2 5 , 2 7 , 2 9 NO T E 6 KB - 1 4 , 1 6 NO T E 6 KB - 2 KB - 4 KB - 6 KB - 1 0 , 1 2 NO T E 6 KB - 1 7 , 1 9 NO T E 6 KB - 1 8 KB - 2 0 KB - 2 2 KB - 8 KB - 2 4 KB - 7 KB - 4 0 KB - 7 2 KB-40 KB-24 KB-72 KB-8 KB-22 KB-20 KB-18 KB-4 KB-6 KB-2 KB - 2 6 ED C O KB - 9 , 1 1 NO T E 6 E59 E143 E49B E64 E71A E70.2 KDS KB-26 KB - 2 1 KB-21 KB - 7 4 KB-74 KB-79 KB - 7 9 KB - 4 4 KB - 4 8 KB - 5 2 KB - 5 6 KB - 6 0 KB - 6 0 KB - 6 8 KB - 6 4 KB - 7 1 KB - 7 8 KB - 8 2 KB-44 KB-48 KB-52 KB-56 KB-60 KB-68 KB-64 KB-71 KB-78 KB-82 LAV-24 LA V - 2 6 LA V - 2 6 LA V - 2 8 LA V - 2 8 LAV-26 LAV-28 KDS LAV-30 LA V - 3 0 LA V - 2 4 LA V - 2 4 E1.0 ELECTRICAL POWER PLAN BYREVISIONS DRAWN: CHECKED: DATE: SCALE: 54 S o u t h A v e n u e Ma r i e t t a , G A 3 0 0 6 0 40 0 - 8 0 0 - 7 9 8 8 in f o @ c o n v e r g e e n g i n e e r s . c o m DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A GUID O O AL RE Z REGI S TRE D E P R OF ESSIONALE N G IN E E R ELECT R I C A L A TATEOF I R NIA C F OL N S I A A RISER DIAGRAM NO SCALE EXISTING PANEL KB SEC 1 400A MLO 208/120V EXISTING PANEL KB SEC 2 400A MLO 208/120V IT ROOM EXISTING PANEL LAV SEC 1 225A MCB 208/120V TO EXISTING PANEL DPLC 300A BREAKER EXISTING FEED THRU LUGS GENERAL NOTES: 1.PROVIDE PULL STRINGS IN ALL EMPTY CONDUITS. 2.ALL JUNCTION BOXES, CONDUITS, AND WIRES SHALL BE SIZED PER NEC. 3.PROVIDE A CONSTANT HOT FORM PANEL BOARD DIRECTLY TO ALL EMERGENCY BATTERY PACKS/BALLASTS IN ALL EMERGENCY LIGHTING FIXTURES. 4.REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION & MOUNTING HEIGHTS OF ALL LIGHTING FIXTURES SHOWN ON THIS DRAWING. 5.REFER TO DETAIL SHEET FOR SYMBOLS, SPECIFICATIONS AND ABBREVIATIONS. 6.ALL DEVICES AND EQUIPMENT OUTSIDE THE SCOPE OF WORK ARE EXISTING TO REMAIN U.O.N. 7.ELECTRICAL CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY PROBLEMS PERTAINING TO CIRCUIT AVAILABILITY, EXISTING CONDITIONS OR LOAD CAPACITY PRIOR TO COMMENCEMENT OF WORK. RISER DIAGRAM NOTES: 1.ALL EQUIPMENT AND OTHER ELECTRICAL MATERIALS/WORK SHOWN AS EXISTING IN THE RISER DIAGRAM SHALL BE VERIFIED BY CONTRACTOR TO BE EXISTING. WHERE THE METER, DISCONNECT, FEEDER OR OTHER COMPONENTS OF THE TENANT FEEDER DO NOT EXIST AS SHOWN. THE CONTRACTOR SHALL PROVIDE. 2.G.C SHALL COORDINATE WITH EXISTING PLANS. ELECTRICAL ROOM TO EXISTING XFMR 45KVA TLAV EXISTING PANEL LAV SEC 2 225A MLO 208/120V EXISTING FEED THRU LUGS E2.0 ELECTRICAL RISER AND PANELS BYREVISIONS DRAWN: CHECKED: DATE: SCALE: 54 S o u t h A v e n u e Ma r i e t t a , G A 3 0 0 6 0 40 0 - 8 0 0 - 7 9 8 8 in f o @ c o n v e r g e e n g i n e e r s . c o m DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A GUID O O AL RE Z REGI S TRE D E P R OF ESSIONALE N G IN E E R ELECT R I C A L A TATEOF I R NIA C F OL N S I A A BYREVISIONS DRAWN: CHECKED: DATE: SCALE: 54 S o u t h A v e n u e Ma r i e t t a , G A 3 0 0 6 0 40 0 - 8 0 0 - 7 9 8 8 in f o @ c o n v e r g e e n g i n e e r s . c o m DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A No. M34196 JU S T I R.HARD Y REGI S TRE D E P R O F ESSIONAL E N G IN E E R EXP. MECH A N I C A L A TATE OF I R N I A C F OL N S 9/30/2026 MP.1 PLUMBING SPEC. I.GENERAL PROVISIONS A.OVERVIEW 1.ALL WORK DONE UNDER THIS CONTRACT SHALL COMPLY WITH ALL STATE AND LOCAL CODES HAVING JURISDICTION AND WITH THE REQUIREMENTS OF THE UTILITY COMPANIES WHOSE SERVICES MAY BE USED. ALL MODIFICATIONS REQUIRED BY THESE CODES SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL CHARGES. WHERE CODE REQUIREMENTS ARE LESS THAN THOSE SHOWN ON THE PLANS OR IN THE SPECIFICATIONS, THE PLANS AND SPECIFICATIONS SHALL BE FOLLOWED. WHERE APPLICABLE, NFPA REQUIREMENTS SHALL BE MET. 2.IN CASE OF ANY CONFLICTS BETWEEN CONTRACT DOCUMENTS, THE STRICTER/MORE STRINGENT SHALL GOVERN. 3.THE CONTRACTOR SHALL OBTAIN ALL PERMITS, INSPECTIONS, AND APPROVALS AS REQUIRED BY ALL AUTHORITIES HAVING JURISDICTION AND DELIVER CERTIFICATES OF APPROVAL TO THE ENGINEER. ALL FEES AND COSTS OF ANY NATURE WHATSOEVER INCIDENTAL TO THESE PERMITS, INSPECTIONS AND APPROVALS MUST BE ASSUMED AND PAID BY THE CONTRACTOR. 4.THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE PROVISIONS OF O.S.H.A. 5.THE WORKMANSHIP AND MATERIALS COVERED BY THESE SPECIFICATIONS SHALL CONFORM TO ALL ORDINANCES AND REGULATIONS OF THE CITY, COUNTY AND/OR OTHER AUTHORITIES HAVING JURISDICTION. 6.CONTRACTOR SHALL VISIT THE SITE AND EXAMINE EXISTING CONDITIONS BEFORE SUBMITTING BID. NO ALLOWANCE WILL BE MADE FOR LACK OF KNOWLEDGE OF EXISTING CONDITIONS WHEN SUCH CONDITIONS CAN BE DETERMINED BY OBSERVATION. 7.PRIOR TO SUBMITTING DATA FOR OR PURCHASING EQUIPMENT REQUIRING ELECTRICAL SERVICE, THE CONTRACTOR SHALL VERIFY THAT ELECTRICAL CHARACTERISTICS OF EQUIPMENT SUBMITTALS COMPLY WITH ELECTRICAL SERVICE PROVIDED FOR THE SPECIFIED ITEMS OF EQUIPMENT. 8.UPON RECEIPT OF THE CONTRACTOR OF REVIEWED SUBMITTALS FOR EQUIPMENT PROVIDED UNDER THIS DIVISION, THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL SERVICE REQUIREMENTS, I.E., MOTOR HORSEPOWER AND FULL LOAD AMPS, ELECTRICAL SERVICE CHARACTERISTICS (VOLTAGE AND PHASE), AND NUMBER OF SERVICES FOR EACH ITEM OF EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS WITH THE ELECTRICAL DRAWINGS AND SPECIFICATIONS. 9.ITEMS ON OR PROJECTING THROUGH THE CEILING SHALL BE COORDINATED WITH OTHER TRADES. E.EXECUTION 2.THE PLANS DO NOT GIVE EXACT ELEVATIONS OR LOCATIONS OF LINES, NOR DO THEY SHOW ALL THE OFFSETS, CONTROL LINES, OR OTHER INSTALLATION DETAILS. THE CONTRACTOR SHALL CAREFULLY LAY OUT HIS WORK AT THE SITE TO CONFORM TO THE STRUCTURAL CONDITIONS, TO PROVIDE PROPER GRADING OF LINES, TO AVOID ALL OBSTRUCTIONS, TO CONFORM TO DETAILS OF INSTALLATION SUPPLIED BY THE MANUFACTURERS OF THE EQUIPMENT TO BE INSTALLED, AND TO THEREBY PROVIDE AN INTEGRATED, COORDINATED AND SATISFACTORY OPERATING INSTALLATION. DO NOT SCALE DRAWINGS. 3.IF THE CONTRACTOR PROPOSES TO INSTALL EQUIPMENT, INCLUDING PIPING AND DUCTWORK, REQUIRING SPACE CONDITIONS OTHER THAN THOSE SHOWN, OR TO REARRANGE THE EQUIPMENT, HE SHALL ASSUME FULL RESPONSIBILITY FOR THE REARRANGEMENT OF THE SPACE AND CONNECT ARRANGEMENT AT NO ADDITIONAL COST TO THE OWNER, AND SHALL HAVE THE ENGINEER REVIEW THE CHANGE BEFORE PROCEEDING WITH THE WORK. THE REQUEST FOR SUCH CHANGES SHALL BE ACCOMPLISHED BY SHOP DRAWINGS OF THE SPACE IN QUESTION. 4.TEMPORARY FILTERS SHALL BE PROVIDED FOR FANS THAT ARE USED DURING CONSTRUCTION. AT THE TIME OF STARTING THE BALANCING OF THE AIR DISTRIBUTION SYSTEM, NEW FILTERS SHALL BE INSTALLED. 5.THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER LOCATION AND SIZE OF ALL SLOT, HOLES OR OPENINGS IN THE BUILDING STRUCTURE PERTAINING TO HIS WORK, AND FOR THE CORRECT LOCATION OF SLEEVES, INSERTS, CORES, ETC. 6.THE CONTRACTOR SHALL SO COORDINATE THE WORK OF THE SEVERAL VARIOUS TRADES THAT IT MAY BE INSTALLED IN THE MOST DIRECT AND WORKMANLIKE MANNER WITHOUT HINDERING OR HANDICAPPING THE OTHER TRADES. PIPING INTERFERENCES SHALL BE HANDLED BY GIVING PRECEDENCE TO PIPE LINES WHICH REQUIRE A STATED GRADE FOR PROPER OPERATION. FOR EXAMPLE SEWER LINES AND CONDENSATE PIPING SHALL TAKE PRECEDENCE OVER WATER LINES IN DETERMINATION OF ELEVATIONS. WHERE THERE IS INTERFERENCE BETWEEN SEWER LINES AND CONDENSATE LINES, THE SEWER LINES SHALL HAVE PRECEDENCE AND PROVISIONS SHALL BE MADE IN THE CONDENSATE LINES FOR LOOPING THEM AROUND THE SEWER LINES. IN ALL CASES, LINES REQUIRING A STATED GRADE FOR THEIR PROPER OPERATION SHALL HAVE PRECEDENCE OVER ELECTRICAL CONDUIT AND DUCTWORK. 7.ALL PIPING AND DUCTWORK IN FINISHED AREAS- EXCEPT WHERE NOTED TO THE CONTRARY- SHALL BE INSTALLED IN A CHASE, FURRED SPACE, OR ABOVE CEILINGS, ETC. IN ALL CASES, PIPES AND DUCTS SHALL BE INSTALLED AS HIGH AS POSSIBLE. RUNS OF PIPING SHALL BE GROUPED WHENEVER IT IS FEASIBLE TO DO SO. 8.PIPING SHALL BE INSTALLED TO PASS INSPECTIONS BY LOCAL PLUMBING INSPECTION DEPARTMENT, STATE AND FEDERAL AUTHORITIES AND INSURANCE COMPANY HAVING JURISDICTION. ANY CHANGES OR ADDITIONS WHICH MAY BE NECESSARY TO OBTAIN SUCH INSPECTIONS AND APPROVAL SHALL BE MADE BY THE CONTRACTOR AS PART OF THIS CONTRACT AND WITHOUT ADDITIONAL COST TO THE OWNER. 9.PIPING, DUCTWORK OR EQUIPMENT SHALL NOT BE INSTALLED IN ELECTRICAL EQUIPMENT ROOMS OR ELEVATOR MACHINE ROOMS EXCEPT AS SERVING ONLY THOSE ROOMS. OUTSIDE OF ELECTRICAL EQUIPMENT ROOMS, DO NOT RUN PIPING OR DUCTWORK OR LOCATE EQUIPMENT, WITH RESPECT TO SWITCHBOARDS, PANEL BOARDS, POWER PANELS, MOTOR CONTROL CENTERS, DRY TYPE TRANSFORMERS OR ROOF TOP AIR CONDITIONING UNIT ELECTRICAL PANELS. 10.PROVIDE ACCESS TO EQUIPMENT AND APPARATUS REQUIRING OPERATION, SERVICE OR MAINTENANCE WITHIN THE LIFE OF THE SYSTEM. INCLUDING, BUT NOT LIMITED TO, MOTORS, VALVES, FILTERS, DAMPERS, SHOCK ABSORBERS, ETC. EQUIPMENT LOCATED ABOVE LAY-IN TYPE CEILINGS IS CONSIDERED ACCESSIBLE. 11.DAMAGED EQUIPMENT SHALL BE REPAIRED OR REPLACED AT THE OPTION OF THE ARCHITECT H.ACCESS DOORS 7.FURNISH AND INSTALL ACCESS DOORS AT EACH POINT REQUIRED TO PROVIDE ACCESS TO CONCEALED VALVES, CLEANOUTS AND OTHER DEVICES REQUIRING OPERATION, ADJUSTMENT OR MAINTENANCE. ACCESS DOORS SHALL BE 16 GAUGE STEEL, PRIME COAT FINISH, WITH MOUNTING STRAPS, CONCEALED HINGES AND SCREWDRIVER LOCKS, DESIGNED FOR THE DOORS TO OPEN 180 DEGREES. 8.ACCESS DOORS INSTALLED IN FIRE WALLS OR PARTITIONS SHALL BE UL LABELED TO MAINTAIN THE FIRE RATING OF THE WALL OR PARTITION. II.INSULATION A.GENERAL PIPE INSULATION 1.FIBERGLASS SHALL BE ACCEPTABLE FOR INDOOR HOT & COLD DOMESTIC; HYDRONIC PIPING; AND INSULATED DRAINAGE PIPING. PROVIDE PREFABRICATED FITTINGS FOR ELBOWS AND TEE'S. PROVIDE PREFAB PVC FITTINGS OR WHITE ALL SERVICE (INTEGRAL TO PREFAB PIPING ELBOW) PIPING ELBOW JACKETING. PROVIDE PIPE LABELING FOR ALL INSULATED, JACKETED INDOOR PIPING. PVC JACKETING SHALL NOT BE PERMITTED IN RETURN PLENUM AREAS. ALL JACKEING SEAMS SHALL BE SEALED AIR-TIGHT FOR CONTINUOUS VAPOR BARRIER. 2.FITTINGS AND VALVES SHALL BE INSULATED WITH PRE-FORMED FITTINGS, FABRICATED SECTIONS OF PIPE INSULATION, TANK INSULATION, BLANKET INSULATION, OR INSULATING CEMENT. THICKNESS SHALL BE EQUAL TO ADJACENT PIPE INSULATION. FINISH SHALL BE WITH PRE-FORMED PVC FITTING COVERS OR AS OTHERWISE SPECIFIED ON CONTRACT DRAWINGS. 3.FLANGES, COUPLINGS AND VALVE BONNETS SHALL BE COVERED WITH AN OVERSIZED PIPE INSULATION SECTION SIZED TO PROVIDE THE SAME INSULATION THICKNESS AS ON THE MAIN PIPE SECTION. AN OVERSIZED INSULATION SECTION SHALL BE USED TO FORM A COLLAR BETWEEN THE TWO INSULATION SECTIONS WITH LOW-DENSITY BLANKET INSULATION BEING USED TO FILL GAPS. JACKETING SHALL MATCH THAT USED ON STRAIGHT PIPE SECTIONS. ROUGH CUT ENDS SHALL BE COATED WITH SUITABLE WEATHER OR VAPOR RESISTANT MASTIC AS DICTATED BY THE SYSTEM LOCATION AND SERVICE. ON HOT SYSTEMS WHERE FITTINGS ARE TO BE LEFT EXPOSED, INSULATION ENDS SHOULD BE BEVELED AWAY FROM BOLTS FOR EASY ACCESS. B.INSULATION THICKNESS 1.DOMESTIC COLD WATER INSULATION SHALL BE 1” MINIMUM OR AS REQUIRED BY LOCAL ENERGY CODES. 2.FOR MEDIA BELOW 60 DEGREES INSULATION SHALL BE 1” UP TO 1-¼” PIPE SIZE; 1.5” THICK UP TO 3” PIPE SIZE; AND 2” THICK BEYOND 3” PIPE SIZE. 3.CHILLED WATER PIPING INSULATION SHALL BE 1” UP TO 1-1/4” PIPE SIZE, 1.5” UP TO 3”. 4.PROVIDE MINIMUM PIPE INSULATION RATING PER INSULATION TABLE 403.2.10 ON THIS SHEET. C.FIBERGLASS PIPE INSULATION 1.ONE PIECE FIBROUS GLASS PIPE INSULATION WITH FACTORY APPLIED ALUMINUM FOIL AND WHITE KRAFT PAPER FLAME RETARDANT VAPOR BARRIER JACKET. 2.PROVIDE SELF_SEALING LONGITUDINAL JACKET LAPS AND BUTT STRIPS. AVERAGE THERMAL CONDUCTIVITY: 0.23 BTU/IN. PER SQUARE FOOT PER DEGREES F PER HOUR AT 75 DEGREES F MEAN TEMPERATURE. 3.PROVIDE INSULATION CEMENT, FIBERGLASS REINFORCEMENT FABRIC, VAPOR BARRIER COATING, FOR CONTINUOUS, AIR-TIGHT INSULATION WITH VAPOR BARRIER. E.FOAMGLASS PIPE INSULATION 1.FOAM GLASS TYPE PIPE INSULATION SHALL HAVE MAXIMUM K_FACTOR OF 0.38 AT 50 DEGREES F MEAN TEMPERATURE. MINIMUM DENSITY SHALL BE 8 LB/CU. FT., 1 1/2" THICK MINIMUM. PROVIDE MASTIC, FIBERGLASS REINFORCED STRAPPING TAPE TO ASSURE AIR-TIGHT MOISTURE-PROOF INSULATION. PROVIDE WITH ALUMINUM JACKETING THAT SHALL BE 0.016" THICK WITH FITTING COVERS 0.024" THICK. PROVIDE WITH 5 WATT/FT HEAT TRACING BELOW INSULATION FOR OUTDOOR, ABOVE-GROUND INSTALLATION. 2.PROVIDE FOAM GLASS INSERTS AT PIPE HANGERS, CLAMPS, OR OTHER SUPPORTS IN FIBERGLASS OR ELASTOMERIC PIPE INSULATION INSTALLATIONS INSERTS SHALL BE SAME THICKNESS AS ADJOINING PIPE INSULATION. VAPOR SEAL SHALL BE AS HEREINBEFORE SPECIFIED. ALUMINUM JACKETING SHALL NOT BE REQUIRED FOR INDOOR INSERTS (PVC OR WHITE ALL-SERVICE FOIL/KRAFTJACKETING MEDIA SHALL BE USED). E.ELASTOMERIC (CLOSED CELL FOAM) PIPE INSULATION 1.ELASTOMERIC SHALL BE PROVIDED FOR ALL REFRIGERANT PIPING AND OUTDOOR INSULATED PIPING AND MAY BE USED FOR INDOOR DOMESTIC OR CONDENSATE PIPING. PIPING WILL REQUIRE JACKETING- ALUMINUM FOR OUTDOOR PIPING OR FOIL/WHITE KRAFT MEDIA OR PVC FOR INDOOR PIPING. PROVIDE WITH FULL ADHESIVE ADHERING SEAMS AND JOINTS FOR CONTINUOUS VAPOR BARRIER. ELBOWS SHALL BE FORMED BY CUTTING SEGMENTS AT 30 DEGREE ANGLES (3 SEGMENTS AT EACH 90 DEGREE BEND) WITH MASTIC AT ALL SEAMS. PROVIDE PREFORMED JACKETING ELBOWS AT ALL PIPING ELBOW VI.PIPING A.USE DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE JOINED TOGETHER. B.DOMESTIC WATER & PUMPED CONDENSATE 1.UNDERGROUND WATER SERVICE PIPING 3" IN SIZE AND LARGER SHALL BE CLASS 50 DUCTILE IRON PIPE, AWWA C151, WITH HUB AND SPIGOT, PUSH_ON JOINTS, AND CLASS 50 OR GREATER MECHANICAL JOINT DUCTILE IRON FITTINGS ALL CEMENT LINED PER AWWA C104. MECHANICAL JOINTS FOR DUCTILE IRON PIPE SHALL BE MADE WITH A FOLLOWER GLAND, GASKET, BOLTS AND NUTS. PUSH-ON JOINTS FOR DUCTILE PIPE SHALL BE MADE WITH A ONE PIECE LUBRICATED COMPRESSION RUBBER GASKET AS PER AWWA C111. 2.UNDERGROUND STEEL PIPE AND FITTINGS INCLUDING THE PORTION THROUGH THE FLOOR SHALL BE PROTECTED AGAINST CORROSION BY APPLICATION OF PROTECTIVE COATINGS. PRIOR TO COATING, PIPE AND FITTINGS SHALL BE CLEANED OF ALL RUST, SCALE, DIRT AND OIL. PIPES AND FITTINGS SHALL BE GIVEN TWO COATS OF A COAL-TAR BASE BITUMINOUS PROTECTIVE COATING, EACH HAVING A DRY FILM THICKNESS OF 7-9 MILS. THE COMBINED THICKNESS OF BOTH COATS COMBINED SHALL BE 15-18 MILS. 3.UNDERGROUND WATER SERVICE PIPING 2 1/2" IN SIZE AND SMALLER (TO A POINT 1'-0" ABOVE THE FINISHED FLOOR) SHALL BE. TYPE "K" HARD DRAWN COPPER TUBING, ASTM B88, WITH BRAZED JOINTS AND WROUGHT COPPER, ANSI B16.22, OR CAST BRONZE, ANSI B16.18, SOCKET FITTINGS. . BRAZED JOINTS SHALL BE MADE USING BCUP-5 BRAZING ALLOY WITH A COMPATIBLE FLUX. 4.ABOVE-GROUND WATER PIPING - 4" AND SMALLER SHALL BE. TYPE "L" HARD DRAWN COPPER TUBING, ASTM B88, WITH SOLDERED JOINTS AND WROUGHT COPPER, ANSI B16.22, OR CAST BRONZE, ANSI B16.18, SOCKET FITTINGS. SOLDER JOINTS SHALL BE MADE USING A 95-5 TIN-ANTIMONY SOLDER (NO-LEAD SOLDER) WITH A COMPATIBLE FLUX. 5.UNDERGROUND WATER PIPING TO TRAP PRIMERS OR HVAC CONDENSATE PUMP DISCHARGE SHALL BE. TYPE “L” SOFT DRAWN COPPER TUBING, ASTM B88, WITHOUT FITTINGS. 6.FLANGED JOINT SHALL BE MADE WITH RING TYPE NON-METALLIC GASKETS, BOLTS AND NUTS. 7.THREADED JOINTS AT EQUIPMENT CONNECTIONS SHALL BE MADE UP WITH TEFLON TAPE. AFTER CUTTING BUT PRIOR TO THREADING, PIPE SHALL BE REAMED AND SHALL HAVE BURRS REMOVED. 8.GROOVED MECHANICAL JOINTS: GROOVED JOINTS FOR COPPER AND GALVANIZED STEEL PIPES SHALL BE INSTALLED USING BOLTED MECHANICAL COUPLING, PRESSURE-RESPONSIVE GASKET ALONG WITH GROOVED AND FITTINGS. LAYOUT BASIS SHALL BE ANVIL GRUV-LOCK, 9.DIELECTRIC ADAPTERS SHALL BE PROVIDED BETWEEN COPPER AND IRON PIPE CONNECTIONS AND BETWEEN FERROUS AND NONFERROUS PIPING OR EQUIPMENT. 10.UNDERGROUND WATER PIPING SHALL HAVE A MINIMUM COVER OF 3'- 0" TO THE TOP OF THE PIPE. 11.INSTALL WATER HAMMER ARRESTORS ABOVE CEILING ON THE HOT AND COLD WATER BRANCH LINES SERVING A BATTERY OF FIXTURES; ON THE COLD WATER BRANCH LINES SERVING INDIVIDUAL FLUSH VALVE WATER CLOSETS AND URINALS; AND ELSEWHERE AS INDICATED ON THE DRAWINGS. PROVIDE ACCESS PANEL FOR WHA LOCATED ABOVE HARD CEILINGS. 12.VACUUM BREAKERS SHALL BE PROVIDED ON ALL HOSE OUTLETS, HOSE BIBS AND HYDRANTS UNLESS THE DRAWINGS INDICATE THAT A BACKFLOW PREVENTER IS TO BE PROVIDED ON THE PIPING SERVING THE OUTLET. 13.INSTALL 1/2" CW LINE FROM NEAREST CW MAIN OR BRANCH LINE TO ALL FLOOR DRAINS WITH TRAP PRIMER FOR TRAP PRIMING. UNDERGROUND PIPING FROM TRAP PRIMER TO FLOOR DRAINS SHALL BE INSTALLED WITHOUT FITTINGS. TRAP PRIMERS SHALL BE PROVIDED FOR ALL FLOOR DRAINS AND HUB DRAINS. 14.CONNECT HOT AND COLD WATER PIPING SYSTEM TO EQUIPMENT AS INDICATED, AND COMPLY WITH EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE SHUT-OFF BALL VALVE AND UNION FOR EACH CONNECTION, PROVIDE DRAIN VALVE ON DRAIN CONNECTIONS. PROVIDE SINGLE SHUTOFF BALL VALVE FOR HEADERS SERVING HOT OR COLD WATER TO MULTIPLE FIXTURES WITHIN A SINGLE WALL OR CHASE. PROVIDE ACCESS PANEL FOR VALVES INSTALLED ABOVE HARD CEILINGS. 15.ALL DOMESTIC WATER SERVICE AND SUPPLY PIPING INSTALLED UNDER THIS DIVISION SHALL BE DISINFECTED WITH CHLORINE BEFORE IT IS PLACED INTO OPERATION. THE CHLORINATING MATERIAL SHALL BE LIQUID CHLORINE CONFORMING TO FED. SPEC. BB-C-120 AND SHALL BE INTRODUCED TO THE SYSTEM BY EXPERIENCED OPERATORS ONLY. THE CHLORINE SOLUTION APPLIED TO THE PIPING SECTIONS OR SYSTEM SHALL CONTAIN AT LEAST FIFTY PARTS PER MILLION OF AVAILABLE CHLORINE AND SHALL REMAIN IN THE SECTIONS OR SYSTEM FOR A PERIOD OF NOT LESS THAN SIXTEEN (16) HOURS. DURING THE DISINFECTION PERIOD ALL VALVES SHALL BE OPENED AND CLOSED AT LEAST FOUR TIMES. AT THE END OF THE RETENTION PERIOD, NO LESS THAN 50 PPM OF CHLORINE SHALL BE PRESENT IN THE EXTREME END OF THIS SYSTEM. AFTER THE DISINFECTION PERIOD THE CHLORINATED WATER SHALL BE FLUSHED FROM THE SYSTEM WITH CLEAR WATER UNTIL THE RESIDUAL CHLORINE CONTENT IS NOT GREATER THAN TWO-TENTHS - (0.2) - PARTS PER MILLION. THE CONSTRUCTION MANAGER SHALL SUBMIT TO THE ARCHITECT WRITTEN CERTIFICATION THAT THE SYSTEM WAS DISINFECTED. CERTIFICATION SHALL INCLUDE NAME OF PROJECT, NAME OF OWNER, NAME OF OPERATORS, DATE OF DISINFECTION, TIMES OF DISINFECTION PERIOD, MAXIMUM CHLORINE LEVEL AND RESIDUAL CHLORINE LEVEL. C.NATURAL GAS 1.ABOVE-GROUND MAXIMUM 2-1/2” GAS PIPING SHALL BE BLACK STEEL PIPE, .SCHEDULE 40, ASTM A53 WITH STANDARD WEIGHT WROUGHT STEEL SOCKET-WELD FITTINGS PER ASTM A234 OR THREADED CONNECTIONS. PIPE SIZES 3" AND UP OR WITH PRESSURE ABOVE 5PSI SHALL ONLY BE PERMITTED WITH SOCKET-WELDED JOINTS (NO THREADED CONNECTIONS). 2.STEEL GAS PIPING TO BE INSTALLED UNDERGROUND SHALL BE FURNISHED WITH A FACTORY APPLIED COATING WHICH SHALL CONSIST OF A RESILIENT, EXTRUDED, POLYETHYLENE SLEEVE WHICH IS SEALED TO THE PIPE. THE PLASTIC COATING SHALL BE NOT LESS THAN 25 MILS THICK AND SEALED TO THE PIPE WITH A HOT APPLIED ADHESIVE WHICH RETAINS ITS ELASTICITY IN HOT AND COLD ENVIRONMENTS. 3.FIELD APPLIED WRAPPING TAPE FOR FITTINGS AND JOINTS SHALL BE COAL TAR WITH HEAVY VINYL OR POLYESTER FILM BACKING MEETING FEDERAL SPECIFICATION HH-T-30A, TAPECOAT CT OR TAPECOAT 20 OR JT JOINT COATINGS, INC., WITH PRIMER, APPLICATION PROCEDURES AND HEATING IN ACCORDANCE WITH THE TAPE MANUFACTURER'S RECOMMENDATIONS. 4.ARRANGE WITH THE UTILITY COMPANY TO PROVIDE GAS SERVICE TO INDICATED LOCATION WITH SHUTOFF AT TERMINATION. MAKE ALL ARRANGEMENTS WITH UTILITY AS TO THE EXTENT OF ITS WORK, AND PAY ALL COSTS, FEES AND SECURE PERMITS INVOLVED TO OBTAIN SERVICE FOR THE BUILDING. 5.PROVIDE SHUTOFF IN GAS SERVICE PIPE AT ENTRY IN BUILDING, EXT/END PIPE TO GAS METER LOCATION INDICATED; PROVIDE PARTS AND ACCESSORIES REQUIRED BY UTILITY TO CONNECT TO METER. 6.PROVIDE VALVE AND UNION SHALL BE PROVIDED AT EACH CONNECTION TO A PIECE OF EQUIPMENT. EQUIPMENT PROVIDED WITH A FLANGED INLET SHALL HAVE A FLANGED CONNECTION. 7.DRIP LEGS, 6-INCHES LONG, SHALL BE PROVIDED IN GAS PIPING AT ENDS OF HORIZONTAL RUNS, AT THE BASE OF RISERS AND AT CONNECTIONS TO EQUIPMENT. DRIP LEG CAP SHALL BE REMOVABLE WITH MINIMUM 4” BETWEEN CAP AND WALL OR ROOF. 8.GAS PIPING WITHIN THE BUILDING SHALL BE RUN ABOVE FLOOR SLAB. 9.PRESSURE REGULATORS ARE TO BE PROVIDED ON ALL EQUIPMENT IF NOT PROVIDED AS PART OF THE EQUIPMENT. COORDINATE INLET/OUTLET PRESSURES WITH ACTUAL DELIVERED PRESSURE AND EQUIPMENT INLET PRESSURES. CONTRACTOR SHALL ARRANGE FOR ADJUSTMENT OF GAS PRESSURE TO PREVENT EXCESSIVE OR INSUFFICIENT GAS PRESSURE TO ALL EQUIPMENT PIECES. 10.PROVIDE FLEX HOSE CONNECTION TO ALL INDOOR APPLIANCES NOT SUPPLIED WITH THE EQUIPMENT PIECE BY THE OWNER OR EQUIPMENT PROVIDER. 11.THREADED JOINTS SHALL BE MADE WITH A MIXTURE OF GRAPHITE AND OIL APPLIED TO MALE THREADS ONLY. AFTER CUTTING AND PRIOR TO THREADING, PIPE SHALL BE REAMED AND SHALL HAVE BURRS REMOVED. 12.WELDED JOINTS SHALL BE FUSION WELDED IN ACCORDANCE WITH ANSI B31, SECTION 6. 13.FLANGED JOINTS SHALL BE FACED TRUE, PROVIDED WITH GASKET AND MADE SQUARE AND TIGHT. 14.BRAZED JOINTS SHALL BE MADE UP USING BCUP-5 BRAZING ALLOY WITH A COMPATIBLE FLUX. 15.ALL STEEL FITTINGS AND JOINTS IN UNDERGROUND PIPING SHALL BE FIELD-COATED USING A PRIMER AND FLEXIBLE POLYETHYLENE TAPE AND THE SAME MANUFACTURER AS THE PIPE COATING. DAMAGED COATING SHALL BE REPAIRED WITH PRIMER AND TAPE AS SPECIFIED FOR FITTINGS AND JOINTS. D.SANITARY WASTE &VENT, STORM, GREASE WASTE 1.UNDERGROUND SANITARY, WASTE AND VENT PIPING, AND STORM DRAINAGE PIPING, AND INDOOR PIPING ABOVE 8” IN SIZE SHALL BE SERVICE WEIGHT (COATED) CAST IRON SOIL PIPE AND FITTINGS, ASTM A74, WITH GASKET HUB AND SPIGOT JOINTS, ASTM C564. GASKET JOINTS FOR CAST IRON PIPE SHALL BE MADE WITH LUBRICATED NEOPRENE COMPRESSION GASKETS. PVC SHALL BE PERMITTED IF ALLOWED BY LOCAL CODE. UNDERGROUND PVC PIPING SHALL BE SCHEDULE 40 PVC WITH SOLVENT WELD JOINTS MEETING ASTM D-1785 AND ASTM D-2665. 2.ABOVE-GROUND SANITARY, WASTE AND VENT AND STORM DRAINAGE PIPING 8" AND SMALLER SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE AND FITTINGS, ASTM A888 AND CISPI 301, WITH STANDARD NO-HUB COUPLINGS. PVC SHALL BE PERMITTED OUTSIDE OF RETURN AIR PLENUMS WITH OWNER APPROVAL. NEOPRENE RUBBER GASKET AND MINIMUM 24 GAUGE TYPE 304 STAINLESS STEEL SHIELD AND FOUR STAINLESS STEEL BANDS FOR SIZES 1 1/2" THROUGH 4", SIX BANDS MINIMUM FOR SIZED 5" AND LARGER. 6” PIPE AND UP: NEOPRENE ELASTOMERIC GASKET AND SERIES 300 STAINLESS STEEL SHIELD AND MULTIPLE DRAW BANDS AND SCREW CLAMPS CONFORMING TO ASTM C-564 AND CISPI STANDARD 310-90. ABOVE-GROUND SANITARY PIPING, LOCATED OUTSIDE OF RETURN AIR PLENUMS MAY ALSO BE SCHEDULE 40 PVC WITH SOLVENT WELD JOINTS MEETING ASTM D-1785 AND ASTM D-2665 PER OWNER APPROVAL. 3.ALL WASTE PIPING 1" IN SIZE AND SMALLER SHALL BE TYPE "L" HARD DRAWN COPPER TUBING, ASTM B88, WITH SOLDERED JOINTS AND WROUGHT COPPER, ANSI B16.22, OR CAST BRONZE, ANSI B16.18, SOCKET FITTINGS. SOLDERED JOINTS FOR TYPE 'L' COPPER TUBING AND CAST DMV BRONZE PIPE SHALL BE MADE WITH 95-5 TIN-ANTIMONY (NO LEAD) SOLDER AND COMPATIBLE FLUX. E.PIPING HANGERS 1.PROVIDE CLEVIS SUPPORTS WITH BEAM CLAMP, CONCRETE ANCHORS (CONCRETE STRUCTURE), SCREWED BRACKET (WOOD STRUCTURE). PROVIDE HANGER OUTSIDE OF INSULATION WITH RIGID FOAM GLASS INSULATION SECTION AT HANGERS. PROVIDE 16 GAUGE PIPING SADDLE AT EACH HANGER. NO WELDING OR CUTTING OF STEEL STRUCTURAL MEMBERS SHALL BE PERMITTED. LAYOUT BASIS SHALL BE ANVIL 260. 2.PROVIDE SEISMIC HANGERS PER DRAWING REQUIREMENTS. 3.HANGER INSTALLATION FOR HOT WATER PIPING SHALL NOT PREVENT MOVEMENT FOR PIPING EXPANSION. 4.SPACING AS FOLLOWS: STEEL PIPE: 1/2” TO 1-1/4” - 7' ; 1-1/2” TO 2-1/2” - 9' ; 3”&4” - 12' ; 6“&8” - 17' ; 10” AND UP- 22' COPPER PIPE: 1/2” TO 1” - 5' ; 1-1/4” TO 2” - 7' ; 2-1/2” AND UP - 9' CAST IRON: 10' WITH SUPPORT AT EACH JOINT, TAKEOFF, AND FITTING. VII.VALVES/PUMPS A.GENERAL 1.VALVES SHALL HAVE THE NAME OR TRADEMARK OF THE MANUFACTURER AND THE WORKING PRESSURE STAMPED OR CAST ON THE VALVE BODY. 2.ALL VALVES IN EACH SYSTEM, EXCEPT FOR SPECIAL TYPES SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER. 3.ALL VALVES REQUIRING PACKING SHALL BE DESIGNED AND CONSTRUCTED SUCH THAT THEY CAN BE REPACKED UNDER PRESSURE. 4.VALVE HAND WHEELS/ ACTUATOR SHALL BE MALLEABLE IRON EXCEPT WHERE SPECIFIED OTHERWISE. 5.ALL VALVES INSTALLED IN HORIZONTAL LINES SHALL BE INSTALLED WITH THE STEMS HORIZONTAL OR ABOVE. VALVE ACTUATOR SHALL BE ORIENTED, WHEN INSTALLED, TO PROVIDE MAXIMUM ACCESSIBILITY FOR OPERATION. 6.PROVIDE ACCESS PANELS FOR VALVES LOCATED IN WALLS OR ABOVE HARD CEILINGS. B.VALVES FOR HYDRONIC / DOMESTIC WATER SYSTEM 1.BALL VALVES (FOR PIPING 3" AND SMALLER) SHALL HAVE BRONZE BODY, STAINLESS STEEL BALL, LEVER HANDLE, FOR SYSTEMS UP TO 125 PSIG. GATE VALVES SHALL NOT BE PERMITTED FOR PIPES 3” AND SMALLER. VALVE LAYOUT BASIS SHALL BE WATTS B6000-SS 2.GATE VALVES (FOR DOMESTIC PIPING 4" IN SIZE AND LARGER): VALVE SHALL HAVE IRON BODY, BRONZE TRIM, NON-RISING STEM, SOLID WEDGE AND FLANGED ENDS FOR 200 POUND W.O.G. LAYOUT BASIS FOR VALVE SHALL BE NIBCO F-619. 3.BUTTERFLY VALVES (FOR HYDRONIC PIPING 4” AND LARGER): VALVE SHALL HAVE DUCTILE IRON BODY, EXTENDED NECK, GEOMETRIC DRIVE MOLDED-IN SEAT LINER, EPDM LINER AND ALUMINUM BRONZE DISC - INSTALL BETWEEN STD. ANSI CLASS 125/150 FLANGES - CONFORMING TO MSS-SP67/MSS-SP25/API-609. LAYOUT BASIS SHALL BE NIBCO WD 2000. 4.CHECK VALVES (4" IN SIZE AND LARGER): VALVE SHALL BE HORIZONTAL SWING TYPE WITH IRON BODY, BRONZE TRIM AND FLANGED ENDS FOR 200 POUND W.O.G. VALVE LAYOUT BASIS SHALL BE NIBCO F-918-B. 5.CHECK VALVES (3" IN SIZE AND SMALLER): VALVE SHALL BE HORIZONTAL SWING TYPE WITH BRONZE BODY, COMPOSITION DISC AND SOLDER ENDS FOR 200 POUND W.O.G. LAYOUT BASIS SHALL BE NIBCO S/T-413. 6.HOSE END DRAIN VALVES: VALVE SHALL BE 3/4" IN SIZE WITH BRONZE BODY, NON-RISING STEM, SOLID WEDGE, THREADED INLET AND HOSE OUTLET WITH CAP AND CHAIN FOR 200 POUND W.O.G. 7.UNDERGROUND GATE VALVES AND VALVE BOXES: GATE VALVES (4" IN SIZE AND LARGER) SHALL BE AWWA APPROVED WITH IRON BODY, BRONZE TRIM, NON-RISING STEM, PARALLEL SEAT DOUBLE DISC, SQUARE OPERATING NUT AND MECHANICAL JOINT ENDS FOR 200 POUND W.W.P. VALVE BOXES SHALL BE PROVIDED OVER EACH UNDERGROUND GATE VALVE. VALVE BOXES SHALL BE ADJUSTABLE CAST IRON ROADWAY TYPE WITH BELLED LOWER SECTION AND REMOVABLE LID AT GRADE. LID SHALL BE LABELED "WATER" AND BOXES NOT IN PAVED AREAS SHALL BE SET IN A 12" X 12" X 6" CONCRETE PAD. VALVE BOXES LAYOUT BASIS SHALL BE MUELLER H-10360 PROVIDE ONE T-WRENCH FOR EACH SIZE OPERATING NUT. C.VALVES FOR NATURAL GAS SYSTEM 1.PLUG VALVES (3" IN SIZE AND LARGER): VALVES SHALL BE THE SEMI-STEEL TYPE WITH CAST IRON BODY, LUBRICATED CAST IRON PLUG, FLANGED ENDS AND WRENCH OPERATED FOR 175 POUND W.O.G. VALVES LAYOUT BASIS SHALL BE WALWORTH1797F 2.PLUG VALVES (2 1/2" IN SIZE AND SMALLER): VALVES SHALL HAVE BRONZE BODY AND PLUG, THREADED ENDS AND SQUARE HEAD FOR 175 POUND W.O.G. VALVE LAYOUT BASIS SHALL BE: WALWORTH NO. 1736 3.BALL VALVES (1/2”, 3/4”, AND 1” UP TO 1/2 PSI FOR APPLIANCE CONNECTION): VALVE SHALL BE LEVER HANDLE, 600 PSI CWP RATED - 1/2 PSI FOR INDOOR APPLIANCE CONNECTIONS PER ANSI Z21.15 & CGA 9.1A. LAYOUT BASIS SHALL BE NIBCO GB1A. 4.LUBRICATED PLUG VALVES SHALL BE LUBRICATED AT THE FACTORY AND SEALANT SHALL BE DESIGNED FOR NATURAL GAS. PROVIDE SIX (6) STICKS OR TUBES OF SEALANT UTILIZED AND TURN SUCH OVER TO THE OWNER. PROVIDE ONE (1) VALVE WRENCH FOR EACH SIZE AND TYPE OF VALVE HEAD AND TURN SUCH WRENCHES OVER TO THE OWNER. 5.PRESSURE REGULATING VALVE: VALVE SHALL HAVE INTERCHANGEABLE ALUMINUM ORIFICE, MOLDED DEEP CONVOLUTION DIAPHRAGM WITH O-RING SEAL, PLATED STEEL DIAPHRAGM PLATE, STAINLESS STEEL LEVER PIN, ONE PIECE MOLDED BUNA-N VALVE SEAT, DIE CAST ZINC VALVE STEM, DELRINFI VENT VALVE WITH BUNA-N SEAT, SPRING LOADED INTERNAL RELIEF VALVE ASSEMBLY, 1" AND 3/4" THREADED VENT WITH STAINLESS STEEL SCREEN, FIBERGLASS REINFORCED POLETHELYNE SEAL CAP WITH INTEGRAL RELIEF VALVE STOP, AND FIELD INTERCHANGEABLE ADJUSTMENT SPRING, CSA 6-18 APPROVED. PROVIDE THREE SPRINGS AT RATED OUTLET PRESSURE PLUS SPRING FOR NEXT HIGHES AND LOWEST PRESSURE RATING FOR BALANCING PURPOSES. PROVIDE ALL VENTING REQUIRED BY THE MANUFACTURER FOR ALL INDOOR MOUNTED REGULATORS. LAYOUT BASIS SHALL BE ACTARIS B42N. 6.CONTRACTOR SHALL PROVIDE REGULATORS AT ALL APPLIANCE CONNECTIONS REGARDLESS OF SUPPLY PRESSURE UNLESS THE REQUIRED EQUIPMENT DELIVERY PRESSURE CAN BE DELIVERED WITHOUT THE USE OF A REGULATOR. 7.CONTRACTOR TO COORDINATE INLET/OUTLET PRESSURES WITH DRAWINGS AND GAS EQUIPMENT MANUFACTURERS REQUIREMENTS. 8.INSTALL ALL REGULATORS CLEAR OF ANY EQUIPMENT ACCESS SUCH THAT VALVE SPRINGS AND ORIFICE CAN BE ACCESSED WITHOUT REMOVING VALVE. 1.THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS. IT IS INTENDED THAT A COMPLETE PLUMBING AND FIRE PROTECTION SYSTEM BE PROVIDED WITH ALL NECESSARY EQUIPMENT, APPURTENANCES AND CONTROLS COMPLETELY COORDINATED WITH ALL DISCIPLINES. ALL PARAMETERS GIVEN IN THESE DOCUMENTS SHALL BE STRICTLY CONFORMED TO. ANY ITEMS AND LABOR REQUIRED FOR A COMPLETE PLUMBING AND FIRE PROTECTION SYSTEM IN ACCORDANCE WITH ALL APPLICABLE CODES, STANDARDS, LOCAL AUTHORITIES AND THESE CONTRACT DOCUMENTS SHALL BE FURNISHED WITHOUT INCURRING ANY ADDITIONAL COST TO THE OWNER. CAREFULLY REVIEW ALL CONTRACT DOCUMENTS AND THE DESIGN OF OTHER TRADES BEFORE PREPARING SHOP DRAWINGS. 2.COORDINATE ALL WORK WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL TRADES. PIPE ROUTING SHOWN IS DIAGRAMMATIC. PROVIDE ALL OFFSETS, ETC. TO AVOID INTERFERENCES WITH EQUIPMENT, PIPING, DUCT WORK, LIGHTS, CONDUITS, AND STRUCTURAL ITEMS, ETC... 3.ALL DRAINAGE PIPING AND POTABLE WATER PIPING SHALL BE CONCEALED INSIDE WALLS AND PIPE CHASES OR ABOVE CEILINGS AS HIGH AS POSSIBLE. 4.EXPOSED PIPING AT FIXTURES SHALL BE SECURED TO WALLS CONSTRAINED AGAINST ANY FREE-MOVEMENT OF PIPING. 5.CONTRACTOR SHALL MAKE FINAL CONNECTION TO ALL DOMESTIC WATER, SANITARY SEWERS, STORM DRAINS, FIRE SUPPLY AND GAS SERVICES AT APPROXIMATELY 5'-0" FROM BUILDING STRUCTURE UNLESS OTHERWISE NOTED. 6.REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR LOCATION OF ALL PLUMBING FIXTURES. EXACT LOCATION OF ALL PLUMBING FIXTURES MUST BE VERIFIED IN FIELD PRIOR TO INSTALLATION. FINAL LOCATIONS AND HEIGHTS SHALL BE AS DIRECTED BY ARCHITECT. 7.PLUMBING CONTRACTOR SHALL MAKE FINAL CONNECTION TO ALL EQUIPMENT INDICATED ON DRAWINGS INCLUDING KITCHEN AND LAUNDRY EQUIPMENT PER MANUFACTURER'S SPECIFIC INSTALLATION INSTRUCTIONS. FINAL CONNECTION SHALL INCLUDE ANY ADAPTERS, NIPPLES SHUTOFF VALVES, PRESSURE REGULATING VALVES, SHOCK ABSORBERS, BACKFLOW PREVENTION DEVICES, ETC. CONTRACTOR SHALL COMPLETELY REVIEW EACH EQUIPMENT ITEM'S INSTALLATION INSTRUCTIONS PRIOR TO COMMENCEMENT OF WORK. ALL ITEMS REQUIRED FOR INSTALLATION ARE INCLUDED IN THE PLUMBING CONTRACTOR'S SCOPE. 8.DO NOT RUN PLUMBING OR FIRE PROTECTION PIPING THROUGH TRANSFORMER VAULTS, ELECTRICAL CLOSETS, ELECTRICAL SWITCHGEAR ROOMS, ELEVATOR EQUIPMENT ROOMS, COMPUTER ROOMS OR TELEPHONE ROOMS. DO NOT RUN ANY PIPING ABOVE ELECTRICAL PANELS OR OTHER ELECTRICAL/CONTROLS COMPONENTS. 9.ALL COMMERCIAL FIXTURES SPECIFIED BY AN EQUIPMENT PROVIDER SHALL OVERRIDE ANY SPECIFIED PLUMBING FIXTURES ON THIS PLAN. THE PLUMBER SHALL COORDINATE FINAL REQUIRED FIXTURES WITH OWNER/EQUIPMENT SUPPLIER. VERIFY CONNECTION SIZE AND LOCATION OF ALL ITEMS WITH KITCHEN EQUIPMENT DRAWINGS. 10.PROVIDE AN EXPANSION JOINT ON ALL PIPING SYSTEMS THAT CROSS BUILDING EXPANSION JOINTS. 11.PROVIDE CONNECTION TO EXISTING WATER SERVICE WHERE AVAILABLE. PROVIDE WATER METER, PRV STATION WITH FULL SIZE BYPASS, AND RPZ VALVE. COORDINATE METER AND BACKFLOW REQUIREMENTS WITH LOCAL AUTHORITY AND UTILTIY COMPANIES. CONNECT TO EXISTING SANITARY AND KITCHEN WASTE STUB WHERE AVAIALBLE. CONNESTIONS TO EXISTING UTILTIES SHALL BE COORDINATED IN THE FIELD FOR EXACT LOCATION AND INVERT AVAILABILITY. 12.PROVIDE GAS CONNECTION TO EXISTING METER WHERE POSSIBLE. PROVIDE CONNECTION TO ROOF MOUNTED EQUIPMENT AND TO KITCHEN EQUIPMENT AS INDICATED ON KITCHEN EQUIPMENT DRAWING. PROVIDE SHUT-OFF VALVES AT ALL POINTS OF CONNECTION. PROVIDE SOLENOID SHUT-OFF VALVE FOR GAS ITEMS UNDER KITCHEN HOODS. INTERLOCK SOLENOID WITH HOOD FIRE PROTECTION SYSTEM. GAS PIPING SHALL NOT BE ROUTED BELOW FLOORS. PIPING INDICATED AS BELOW SLAB SHALL BE PROVIDED IN A PREFABRICATED MODULAR STAINLESS STEEL UTILITY TRENCH. 13.ALL PLUMBING FIXTURES, PIPING, AND MATERIALS SHALL BE LISTED OR LABELED AND INSTALLED AS PER A RECOGNIZED APPROVAL AGENCY. 14.ALL WORK WITHIN THIS SCOPE OF WORK SHALL COMPLY WITH ALL CITY, STATE AND NATIONAL PLUMBING CODES. ALL WORK SHALL CONFORM TO BUILDING STANDARDS. 15.PLUMBING CONTRACTOR SHALL VERIFY VOLTAGE, PHASE AND WIRE SIZE OF PLUMBING EQUIPMENT REQUIRING ELECTRICAL CONNECTION WITH ELECTRICAL CONTRACTOR PRIOR TO PURCHASE OF EQUIPMENT 16.ALL PLUMBING UTILTIY AND SERVICE REQUIREMNTS SHALL BE COORDINATED BY THE CONTRACTOR WITH THE LOCAL CODE AUTHORITIES AND UTILITY COMPANIES. ANY ADDITIONAL REQUIREMENTS FOR UTILTY SERVICES SHALL BE INCLUDED IN CONTRACTOR SCOPE. 17.COORDINATE ALL FLOOR PENETRATIONS WITH STRUCTURAL DRAWINGS. THE PLUMBER SHALL SET SLEEVES IN FLOORS AND WALLS AND ATTACHMENTS FOR HANGERS AS CONSTRUCTION PROGRESSES. COORDINATE THE EXACT SIZE AND LOCATION OF ALL SLEEVES WITH STRUCTURAL ENGINEER. ALL PENETRATIONS MUST BE SEALED AND HELD AS TIGHT TO COLUMNS OR WALLS AS POSSIBLE. 18.COORDINATE ALL UNDERGROUND PIPING WITH GRADE BEAMS, WALL FOOTINGS, COLUMN FOUNDATIONS AND OTHER STRUCTURAL CONDITIONS. 19.ALL DRAINAGE PIPING AND VENT PIPING SHALL SLOPE AT 1/8 INCH PER FOOT UNLESS OTHERWISE NOTED. 20.FLOORS WHERE INDICATED ON ARCHITECTURAL AND /OR STRUCTURAL DRAWINGS SHALL SLOPE TO FLOOR DRAINS. MAXIMUM SLOPE IN ANY DIRECTION SHALL NOT EXCEED ¼ INCH PER FOOT. EXACT LOCATION OF ALL FLOOR DRAINS AND HUB DRAINS FOR EQUIPMENT MUST BE VERIFIED IN FIELD PRIOR TO INSTALLATION. FINAL LOCATION SHALL BE AS DIRECTED BY ARCHITECT. FLOOR DRAIN SHALL BE COMPLETELY FLUSH WITH THE LOWEST LEVEL OF THE FLOOR SLOPE AND SHALL NOT PROTRUDE BEYOND THE FLOOR SO AS TO CAUSE POOLING AROUND THE DRAIN. CUTTING OF ANY FLOOR DRAINAGE FIXTURE GRATE SHALL NOT BE PERMITTED 21.EXACT LOCATION OF ALL CLEANOUTS MUST BE COORDINATED AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. 22.COORDINATE ALL FIXTURE GRATES, ORIENTATIONS, AND REQUIRED GRATE SPACING WITH THE KITCHEN EQUIPMENT SUPPLIER. VERIFY ALL FLOOR DRAIN AND FLOOR SINK LOCATIONS WITH THE KITCHEN CONSULTANT. HALF-GRATES SHALL BE PROVIDED FOR HUB DRAIN COLLECTING INDIRECT SINK DISCHARGE. CONTRACTOR SHALL COORDINATE FINAL FLOOR SINK LOCATIONS WITH SINK SUPPORT LEGS TO AVOID SUPPORTS SITTING ON GRATES. 23.SANITARY VENTS MUST TERMINATE A MINIMUM OF 10 FT. FROM OR 2 FT. ABOVE AIR INTAKES, WINDOWS OR VENT SHAFTS. 24.INDIRECT WASTE RECEPTORS MUST BE LOCATED WHERE READILY ACCESSIBLE FOR INSPECTION AND CLEANING. 25.ALL INDIRECT WASTE PIPING SHALL DISCHARGE THROUGH A CODE REQUIRED AIR GAP OR AIR BREAK INTO A WASTE RECEPTOR. ALL INDIRECT WASTE PIPING THAT EXCEEDS 2' IN DEVELOPED LENGTH MEASURED HORIZONTALLY OR 4' IN TOTAL DEVELOPED LENGTH SHALL BE TRAPPED. 26.ALL HOSE BIBBS AND WASHDOWN FAUCETS ARE REQUIRED TO HAVE PROPER BACKFLOW PREVENTERS WHERE HOSES ARE ATTACHED AND LEFT UNATTENDED. CHEMICAL FEED SYSTEMS AT COMMERCIAL KITCHENS SHALL HAVE DEDICATED BACKFLOW PREVENTERS SEPARATE FROM WASHO-DOWN OR HOSE BIB FIXTURES. 27.PVC PIPING SHALL BE PROHIBITTED IN ANY AIR PLENUM SPACES. PIPING SHALL NOT BE PROVIDED WITHING INSULATED COOLER/FREEZER PANEL WALLS. 28.PROVIDE 12" x 12" ACCESS PANELS FOR SHOCK ABSORBERS, TRAP PRIMERS AND ALL VALVES LOCATED ABOVE NON-ACCESSIBLE CEILINGS AND INSIDE PIPE CHASES. EXACT LOCATION MUST BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. ALL ACCESS PANELS SHALL BE LOCATED SO THAT THEY ARE NOT VISIBLE TO PUBLIC VIEW. 29.WALL HYDRANTS AND HOSE BIBBS SHALL BE MOUNTED 1' - 6" ABOVE GRADE OR FLOOR LEVELS. 30.PIPING ISULATION SHALL BE PROVIDED WITH CONTIUOUS AIR-TIGHT VAPOR BARRIER WITH NO LOOSE TAPE OR EXPOSED INSULATION MATERIAL. CONDENSATE PIPING SHALL BE PROVIDED WITH ELASTOMERIC INSULATION. ALL INSULATION AND WRAPPING JOINTS AND SEEMS SHALL BE PROVIDED WITH 1” OVERLAP AND MANUFACTURER RECOMMENDED, AIR-TIGH MASTIC AT ANY INSULATION OR VAPRO BARIER JOINTS. INSULATION SHALL BE INSTALLED WITH FULL THICKNESS, FREE OF ANY INSUALTION COMPRESSION. PROVIDE RIGID INSULATION SECTION AT ALL PIPING HANGERS. 31.PROVIDE REDUCED PRESSURE BACKFLOW PREVENTER AT ALL CONNECTIONS TO MECHANICAL EQUIPMENT, KITCHEN AND LAUNDRY EQUIPMENT, IRRIGATION AND POOL CONNECTIONS, WATER SOFTENERS, VENDING MACHINES, ETC. AS REQUIRED BY CODE AND LOCAL AUTHORITIES. CONTRACTOR IS TO VERIFY WITH THE LOCAL AUTHORITY THE TYPE OF BACKFLOW PREVENTION DEVICE REQUIRED FOR ALL APPLICATIONS PRIOR TO INSTALLATION. DRAINAGE FIXTURE AND PIPING (HUB DRAIN/FLOOR DRAIN ETC) SHALL BE PROVIDED FOR EACH BFP CONTAINING A BACKFLOW DISCHARGE. 32.EXTEND ALL PVC CONDUITS CONTAINING BEVERAGE LINES, HOT AND COLD WATER PIPING, ETC. BELOW FLOOR/GROUND A MINIMUM OF ONE INCH ABOVE FINISHED FLOOR AND SEAL AROUND PIPING TO ENSURE WATER- TIGHT CONNECTIONS. OFFSET ALL PVC BEVERAGE CONDUITS WITH 24" MINIMUM RADIUS FITTINGS. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR ADDITIONAL DETAILS AND REQUIREMENTS. PVC CONDUITS SHALL BE FIRE WRAPPED OR ENCASED IN 5/8" GYPBOARD. 33.PROVIDE A VALVED BYPASS AT ALL EQUIPMENT INCLUDING WATER HEATERS, STORAGE TANKS WATER SOFTENERS, BOOSTER PUMPS, FIRE PUMPS, ETC… FOR MAINTENANCE OF EQUIPMENT. 34.PROVIDE BALL VALVES AT ALL BRANCH LINES SERVING MULTIPLE FIXTURES. PROVIDE ACCESSIBLE BALL VALVE AT EACH FIXTURE CONNECTION (IN ADDITION TO ANY EXPOSED STOPS) OR FIXTURE HEADER BRANCH CONNECTION. 35.ALL HAND-WASHING BASINS AND LAVATORIES INSTALLED SHALL BE EQUIPPED WITH HOT AND COLD WATER THROUGH A MIXING VALVE UNLESS A TEMPERED WATER SUPPLY IS INDICATED. 36.INSTALL VACUUM BREAKERS A MINIMUM OF 6" ABOVE THE FLOOD LEVEL RIM OF A FIXTURE SERVED WITH NO SHUT-OFF DEVICES BEYOND THE DISCHARGE OF THE VACUUM BREAKER. 37.THE USE OF RISER CLAMPS TO SUPPORT VERTICAL PIPE ALONG WALLS, OR COLUMNS IS PROHIBITED. PROVIDE B-LINE 22 STRUT & B-2000 PIPE CLAMPS 38.CONTRACTOR SHALL HANG ALL PIPING FROM THE STRUCTURAL MEMBERS (W-SHAPES, BAR JOISTS) WITH CLAMP-TYPE CONNECTIONS. PIPING SHALL NOT BE SUPPORTED FROM THE METAL DECK. STRUCTURAL MEMBERS SHALL NOT BE CUT OR DRILLED. 39.ALL JOINTS, ANNULAR SPACES, OR OPENINGS INTO HOLLOW OR INACCESSIBLE AREAS ARE TO BE CLOSED TO 1/32" OR LESS FOR FOOD SERVICE AREAS. 40.ALL ANNULAR SPACES ARE TO BE CLOSED AND ESCUTCHEON PLATES AT HAND WASHING AREAS MUST BE SECURED. 41.TRAP FOR FLOOR DRAINS, FLOOR SINKS, OR HUB DRAINS ASSOCIATED WITH THE FOOD SERVICE AREAS AND NOT AS AN INDIRECT WASTE RECEPTOR SHALL BE PROVIDED WITH A WATER SEAL OF AT LEAST 4" DEEP. 42.INSTALL VACUUM BREAKERS A MINIMUM OF 6" ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE SERVED WITH NO SHUT-OFF DEVICES BEYOND THE DISCHARGE OF THE VACUUM BREAKER. 43.ALL JOINTS, ANNULAR SPACES, OR OPENINGS INTO HOLLOW OR INACCESSIBLE AREAS ARE TO BE CLOSED TO 1/32" OR LESS FOR FOOD SERVICE AREAS. 44.ALL DIRECT CONNECT APPLIANCES SHALL BE INDIVIDUALLY PROTECTED AGAINST BACKFLOW. "CARBONATOR" AND CARBONATED-TYPE SODA DISPENSERS ARE CONSIDERED TO BE "HIGH HAZARD" APPLIANCES AND SHALL BE PROTECTED BY SPECIFICALLY LISTED CO2 BACKFLOW PREVENTERS. ALL OTHER APPLIANCES SUCH AS ICE MACHINES, COFFEE MAKERS, YOGURT DISPENSERS, AND SIMILAR EQUIPMENT WITH DIRECT CONNECTIONS TO POTABLE WATER SHALL BE PROTECTED BY A DOUBLE CHECK VALVE TYPE BACKFLOW PREVENTER. 45.REFER TO FIRE PROTECTION SPEC FOR SPRINKLER DESIGN REQUIREMENTS FOR ALL AREAS IN CONJUNCTION WITH PIPING AND HEADS SHOWN ON DRAWINGS. 46.GC SHALL BE RESPONSIBLE FOR ALL RISER, AND SERVICE COMPONENTS INCLUDING ALL DETECTOR CHECKS, DOUBLE DETECTOR CHECK ASSEMBLIES, PIV, WET AND DRY RISERS, FDC, VAULTS AND OTHER DEVICES REQUIRED FOR ALL AREA NOTED WITH SPRINKLER COVERAGE. GENERAL PLUMBING NOTES BYREVISIONS DRAWN: CHECKED: DATE: SCALE: 54 S o u t h A v e n u e Ma r i e t t a , G A 3 0 0 6 0 40 0 - 8 0 0 - 7 9 8 8 in f o @ c o n v e r g e e n g i n e e r s . c o m DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A No. M34196 JU S T I R.HARD Y REGI S TRE D E P R O F ESSIONAL E N G IN E E R EXP. MECH A N I C A L A TATE OF I R NIA C F OL N S 9/30/2026 F R R 6" FD-1 (ETR) 6" FD-1 (ETR) 6" FD-1 (ETR)6" FD-1 (ETR) 6" FD-1 (ETR) 6" FD-1 (ETR) 6" FD-1 (ETR)6" FD-1 (ETR) 6" FD-1 (ETR) 12" FD-1 (ETR) 12" FD-1 (ETR) 12" FD-1 (ETR) G55 3 G58 3 G58 3 G57 2 G63 2 4 4 GASGASGASGASGASGASGASGASGASGASGASGAS GAS LINE (ETR) 2-1/2"2-1/2" GASGASGASGASGASGASGASGASGASGASGASGA S GA S GA S GA S GA S GASGAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GA S GA S GA S GA S GA S GAS CAP 1 CAP 1 CAP 1 CAP 1 CAP 1 CAP 1 CAP 1CAP 1 GAS GAS GAS 3" GAS LINE (ETR) 2- 1 / 2 " 2- 1 / 2 " 3" GAS LINE FROM ROOF ABOVE (ETR) 2-1/2"3" 2-1/2" G63G57G58G58 G5 5 GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS 3/4" 264 CFH3/4" 120 CFH 3/4" 85 CFH 3/4" 85 CFH1" 357 CFH GAS LINE(ETR) GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GA S GA S GA S GA S GA S GA S 2-1/2" GAS LINE (ETR) CAPEXISTING CAPEXISTING CAPEXISTING CAPEXISTING 2- 1 / 2 " CAPEXISTING 2- 1 / 2 " 3"2 1/2" CAPEXISTING CAPEXISTING CAPEXISTINGCAPEXISTINGCAPEXISTING BYREVISIONS DRAWN: CHECKED: DATE: SCALE: 54 S o u t h A v e n u e Ma r i e t t a , G A 3 0 0 6 0 40 0 - 8 0 0 - 7 9 8 8 in f o @ c o n v e r g e e n g i n e e r s . c o m DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A No. M34196 JU S T I R.HARD Y REGI S TRE D E P R O F ESSIONALE N GI N E E R EXP. MECH A N I C A L A TATE OF I R NIA C F OL N S 9/30/2026 PLUMBING FLOOR PLAN-SANITARY 3/8" = 1'-0" # P1.0 PLUMBING PLANS REFER TO K-SHEETS FOR KITCHEN PLUMBING FIXTURE SCHEDULE, DIMENSIONS AND FIXTURE BRANCH SIZES. OVERALL KEY PLAN N.T.S. GAS PIPE DROP ROOF DRAIN BALL VALVE GAS PIPING CW PIPING HW PIPING HOT WATER RECIRCULATION PIPING VENT PIPING SANITARY PIPING (LONG DASH) GREASE WASTE (SHORT DASH)STRAINER PRV CHECK VALVE METER NAT GAS REGULATOR 3 WAY VALVE 2 WAY VALVE BUTTERFLY VALVE CIRCUIT SETTER FLOW CONTROL VALVE GAGE PT PLUG PUMP DOUBLE CHECK VALVE FLEX PIPE/CONNECTION THERMOMETER AUTO AIR VENT FROSTAT UNION RPZ CHECK GAS LEGEND NOTE: EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS & SITE VISITS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. GENERAL DEMO NOTES: 1.PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT, ENGINEER AND/OR OWNER OF CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2.EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT “AS-BUILT” CONDITIONS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 3.OWNER RETAINS RIGHTS OF SALVAGE FOR EQUIPMENT AND FIXTURES TO BE REMOVED. COORDINATE WITH THE OWNER THE EQUIPMENT AND FIXTURES TO BE SALVAGED AND THE LOCATION FOR STORAGE. AVOID DAMAGE TO EQUIPMENT, FIXTURES AND DEVICES DURING DEMOLITION WORK AND DURING TRANSPORT TO OWNER'S DESIGNATED STORAGE LOCATION. 4.AVOID DAMAGING EXISTING SURFACES AND EQUIPMENT TO REMAIN FOR NEW INSTALLATION. REPAIR ANY DAMAGE CAUSED DURING WORK AT NO EXTRA COST TO THE OWNER. 5.SEAL ALL PENETRATIONS THROUGH FLOORS, WALLS, CEILINGS AND ROOFS WHERE PLUMBING COMPONENTS ARE REMOVED AND WHERE THE EXISTING PENETRATION IS NOT USED FOR THE NEW INSTALLATION. REPAIR SURFACES TO MATCH ADJACENT AREAS. 6.INSTALL PERMANENT CAPS WHERE PIPING IS REMOVED AND THE EXISTING TAPS ARE NOT USED FOR THE NEW INSTALLATION. INSTALL TEMPORARY CAPS WHERE PIPING IS REMOVED AND THE EXISTING TAPS WILL BE USED FOR THE NEW INSTALLATION TO PROTECT THE INTERIOR SURFACES UNTIL NEW PIPING IS INSTALLED. 7.REMOVE PIPE HANGERS, PIPE SUPPORTS AND EQUIPMENT SUPPORTS WHERE PIPING OR EQUIPMENT IS REMOVED AND THE EXISTING HANGERS AND SUPPORTS ARE NOT USED FOR THE NEW INSTALLATION. 8.VERIFY THAT EXISTING EQUIPMENT TO REMAIN IS OPERATING PROPERLY. NOTIFY THE ARCHITECT, ENGINEER AND/OR OWNER OF ANY DAMAGED AND/OR MALFUNCTIONING COMPONENTS. 9.WHERE SHUTDOWN OF EXISTING ACTIVE PIPING SYSTEMS IS REQUIRED DURING DEMOLITION PHASE OF WORK IN PREPARATION FOR NEW TIE-IN PHASE OF WORK, COORDINATE WITH THE OWNER AND MINIMIZE DOWNTIME. VERIFY EXISTING SYSTEMS, EQUIPMENT, AND COMPONENTS WILL BE PROVIDED WITH BACKUP SERVICE WHERE REQUIRED. NOTIFY OWNER A MINIMUM OF SEVEN (7) DAYS PRIOR TO INTERRUPTION OF SERVICE KITCHEN GENERAL NOTES: 1. REFERENCE KITCHEN EQUIPMENT DRAWINGS FOR ITEMS TO BE FURNISHED AND / OR INSTALLED AND PROVIDE ITEMS AND WORK AS REQUIRED TO COMPLETE THE INSTALLATION OF PLUMBING SYSTEMS FOR KITCHEN EQUIPMENT. REFERENCE THE KITCHEN EQUIPMENT DRAWINGS FOR REQUIRED ROUGH-IN AND FINAL CONNECTIONS FOR KITCHEN EQUIPMENT. REFERENCE THE KITCHEN EQUIPMENT SHOP DRAWINGS PRIOR TO THE START OF INSTALLATION FOR ADDITIONAL REQUIREMENTS. 2.PROVIDE ITEMS AND WORK AS REQUIRED FOR A COMPLETE AND WORKING PLUMBING INSTALLATION FOR EACH PIECE OF KITCHEN EQUIPMENT. PROVIDE ROUGH-INS AND CONNECT TO THE KITCHEN EQUIPMENT WITH TRAPS, SUPPLIES, SHUTOFF VALVES, PIPES TO THE WALL, ESCUTCHEONS, ETC AS SHOWN, SPECIFIED AND REQUIRED. 3.VERIFY GAS LOADS AND GAS ROUGH-IN OF KITCHEN EQUIPMENT WITH THE KITCHEN EQUIPMENT DRAWINGS PRIOR TO INSTALLING GAS PIPING. PROVIDE GAS COCKS, UNIONS, ETC. AS SPECIFIED AND REQUIRED. INSTALL GAS QUICK DISCONNECTS WHERE FURNISHED WITH THE KITCHEN EQUIPMENT. 4.COMPLY WITH HEALTH DEPARTMENT REGULATIONS. PROVIDE CLEARANCE FOR CLEANING BEHIND AND UNDER EXPOSED PIPING AS REQUIRED BY HEALTH DEPARTMENT. CONFORM TO HEALTH DEPARTMENT REQUIREMENTS FOR LOCATIONS OF FLOOR SINKS. 5.COORDINATE LOCATION OF VENT, WATER, AND GAS PIPING TO AVOID CONFLICT WITH OTHER TRADES. 6.LEAN INSTALLED PLUMBING FIXTURES AND EQUIPMENT. 7.SEAL AROUND INSTALLED FIXTURES AND KITCHEN EQUIPMENT WITH CAULK. CONTRACTOR TO COORDINATE WITH ANSUL SYSTEM INSTALLER MODIFICATIONS REQUIRED TO EXISTING HOOD ANSULSYSTEM TO PROVIDE PROPER COVERAGE OF ALL NEW EQUIPMENT BENEATH EXISTING HOOD PLUMBING FIXTURE SCHEDULE: FIXTURES IN THIS SCHEDULE OR THEIR APPROVED EQUIVALENT ARE PROVIDED BY THE PLUMBING CONTRACTOR. SUBMIT SHOP DRAWINGS ON EACH OF THESE ITEMS. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION AND INSTALLATION REQUIREMENTS. VERIFY ROUGH-IN REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE PLUMBING FIXTURE MOUNTING HEIGHTS. THERMOSTATIC MIXING VALVE: POWERS # LFG480, SOLID LEAD FREE BRASS BODY, THERMOSTATIC WAX ELEMENT, CORROSION RESISTANT INTERNAL PARTS, AND INTEGRAL CHECKS, ASSE 1070 COMPLIANT, CAPABLE OF 2.2 GPM WITH A 20 PSI DIFFERENTIAL AND A MINIMUM FLOW RATE OF 0.25 GPM. SET MAXIMUM TEMPERATURE AS INDICATED ON PLANS. TMV TMV # PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES. PLUMBING PLAN NOTE CALLOUT 1 EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) PLUMBING PLAN NOTE CALLOUT (ETR)EXISTING TO REMAIN NOTE: CONTRACTOR SHALL VERIFY ALL GAS FIRED EQUIPMENT CONNECTION LOCATIONS IN THE FIELD PRIOR TO INSTALLING ANY GAS PIPE MAINS OR BRANCHES. INSTALL THE GAS TRAIN SUCH THAT ACCESS PANEL SWINGSHALL NOT BE IMPEDED. FULL SIZE FULL PORT GAS COCK OR BALL VALVE DRIP/DIRT POCKET MAKE CONNECTION TO OR APPLIANCE FLEX HOSE QUICK CONNECTION FITTING OR UNIT GAS MANIFOLD INSIDE CABINET WITH GROUND JOINT UNION. PROVIDE GROMMET IN CABINET FOR WATER-TIGHT SEAL FOR HVAC CONNECTIONS. GAS PIPING EQUIPMENT CONNECTION DETAIL. PRESSURE REGULATOR WITH VENT LIMITER OR VENT TO OUTDOORS. PROVIDE AT EACH APPLIANCE WHEN SERVICE IS GREATER THAN 7" W.C. GAS RISER DIAGRAM N.T.S. 3/4" 360° FREESPIN MALE INLET QUICK CONNECT MALE NIPPLE PLUG BODY 3/4" FEMALE QUICK CONNECT COUPLING SOCKET EXTRUDED COATED STAINLESS BRAIDED GAS APPLIANCE CONNECTOR 3/4" 360° FREESPIN MALE OUTLET TO GAS APPLIANCEFROM GAS SUPPLY LINE GAS APPLIANCE QUICK DISCONNECT KITCHEN GAS SCHEDULE ITEM # CONNECTION SIZE LOOKING UP OR DOWN B.T.U./ HOUR REMARKS USE EXISTING PIPE FOR NATURAL GAS LOOP TO HANDLE: 911,000 TOTAL B.T.U./HR.: G55 1"DOWN 357,000 FRYER ASSEMBLY w/FILTER - QUICK DISCONNECT SUPPLIED BY K.E.C. & INSTALLED BY P.C. G57 3/4"UP 120,000 36" CHARBROILER - P.C. TO INSTALL & SUPPLY GAS PRESSURE - QUICK DISCONNECT SUPPLIED BY K.E.C. & INSTALLED BY P.C. G58 3/4" EACH UP 85,000 EACH 36" PLANCHA - (2) RIP'S - QUICK DISCONNECT SUPPLIED BY K.E.C. & INSTALLED BY P.C. G63 3/4"UP 264,000 48" HOT TOP RANGE - GAS PRESSURE REGULATOR SUPPLIED w/UNIT & INSTALLED BY P.C. - QUICK DISCONNECT SUPPLIED BY K.E.C. & INSTALLED BY P.C. NOTE: THE GAS EQUIPMENT WILL BE INITIALLY SET BY THE K.E.C. THEN THE P.C. WILL USE EXISTING GAS LINE TO VARIOUS CONNECTION POINTS. P.C. IS TO PROVIDE SHUT-OFF'S & INSTALL ALL PRESSURE REGULATORS. P.C. IS TO INSTALL THESE COMPONENTS IN ACCESSIBLE AREAS FOR SERVICING. PLUMBING PLAN NOTES: 1.CAP EXISTING GAS STUB-UP FOR EXISTING EQUIPMENT AT MAIN. 2.CONNECT NEW GAS EQUIPMENT TO EXISTING GAS STUB-OUT. MAKE CONNECTION TO EQUAL OR LARGER EXISTING STUB-OUT AS FIELD CONDITIONS REQUIRE. REFERENCE KITCHEN EQUIPMENT DRAWINGS FOR CONNECTION SIZE AND REQUIREMENTS. 3.CONNECT NEW GAS EQUIPMENT TO EXISTING GAS HEADER. CONNECT TO EXISTING GAS HEADER PER MANUFACTURE'S RECOMMENDATIONS. PROVIDE WITH NEW SHUT-OFF VALVE. EXISTING FIXTURE TO REMAIN. 4.EXISTING FIXTURE TO REMAIN. # ROUGH-IN SET INDEX SHEET K1 INDEX K2 KITCHEN PLAN, SCHEDULE & ELEVATIONS K5 KITCHEN ELECTRICAL & POS PLAN, SCHEDULES & ELEVATIONS K8 KITCHEN PLUMBING & GAS PLAN, SCHEDULES & ELEVATIONS K13 KITCHEN CRITICAL PLAN, SCHEDULE & ELEVATIONS IN D E X S H E E T SHEET DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A K1 1 OF 5 SHEETS BYREVISIONS DRAWN: CHECKED: DATE: SCALE: F R R K80K80A K72BK43B K30 K66 K76 K60 K74A K81AK74 K2 K72A K81AK81B K72C K81A K81B K2 K46A K75 K143 K49K43 K30 K66 K116A K125 EXISTING PASS WINDOW TO REMAIN EXISTING HAND SINK TO REMAIN K70.2 K143 K54 K79 K2 K78/ K141K47 K55 K60 K45 K73K56A K58/B K59 K57/B K102 K143 K78/ K141 K46 K63/B K64 K41 K39K2 K2 EXISTING PASS WINDOW TO REMAIN EXISTING PASS WINDOW TO REMAIN EXISTING KDS TO REMAIN K71 K49B K66K65 RELOCATE EXISTING KDS FROM COOKLINE EXISTING KDS TO REMAIN RELOCATE EXISTING KDS FROM WEST END OF LINE EXISTING KDS TO REMAIN K78/ K141 K78/ K141 K78/ K141 K78/ K141 K7 K7 K7 K7 K30K66 K71 K49 K116AK72CK72AK74AK72BK80 K71 K75K2K2 K66 K30 K43BK80A K7 K76 K70.2 K54K45K59K46K49BK64K2 K2 K39 K143 K79K78 K65 K41 K55 K60K73 K58/BK57/B K63/B K141 K47 K56A K102 EXISTING HAND SINK TO REMAIN EXISTING KDS TO REMAIN K7 K7 ELEVATION "12" DISH-UP LINE EXISTING COLD WINDOW TO REMAIN ELEVATION "14" MAIN COOK LINE EXISTING PASS WINDOW TO REMAIN EXISTING PASS WINDOW TO REMAIN K81A K81B K81A K81B K81A K74 K78 K141 K78 K141 K78 K141 K78 K141 K143 K7 K2 K143 K78 K141 RELOCATE EXISTING KDS EXISTING KDS TO REMAINRELOCATE EXISTING KDS FROM COOK LINEEXISTING KDS TO REMAINEXISTING KDS TO REMAIN K125 K46A K43 K66 K60 K66 K30 K30 K71 K66 KITCHEN EQUIPMENT SCHEDULE ITEM #QTY DESCRIPTION MANUFACTURE MODEL NUMBER PROVIDED BY: INSTALLED BY: NSF LISTED CUSTOM FAB CASTERS /FIXED K2 LOT TRASH RECEPTACLES RUBBER MAID #3540-SLIM JIM OWNER OWNER --- K7 8 CORNER GUARDS @ BOH CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES - K30 3 MICROWAVE WALL SHELF CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K39 1 HAND SINK ADVANCE TABCO 7-PS-62-2X K.E.C.K.E.C.YES -FIXED K39.1 2 HAND SINK SPLASH GUARDS (NOT SHOWN ON PLAN)CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K41 1 POT RACK ADVANCE TABCO SW1-48 K.E.C.K.E.C.YES -FIXED K43 2 PLATE SHELVES CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K43B 2 PLATE SHELVES CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K45 1 UNDER COUNTER FREEZER w/DRAWERS DELFIELD STD4532NP K.E.C.K.E.C.YES -CASTERS K46 1 WORK COUNTER CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K46A 1 WORK COUNTER CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K47 1 WORK COUNTER CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K49 1 PIZZA STATION DELFIELD 18660PTBMP K.E.C.K.E.C.YES -CASTERS K49B 1 SAUTE STATION DELFIELD DA000A15P01 K.E.C.K.E.C.YES -CASTERS K54 1 BREADING STATION DELFIELD DA000A17P01 K.E.C.K.E.C.YES -CASTERS K55 1 FRYER ASSEMBLY w/FILTER FRYMASTER 3FQG60T K.E.C.K.E.C.YES -CASTERS K55A 1 GAS DISCONNECT HOSE (NOT SHOWN ON PLAN)T&S BRASS HG-4E-48SK K.E.C.PLUMBER YES -FIXED K56A 1 DOUBLE WALL SHELF w/BOWL SLIDES CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K57 1 CHARBROILER SOUTHBEND HDC-36 K.E.C.K.E.C.YES -- K57A 1 GAS DISCONNECT HOSE (NOT SHOWN ON PLAN)T&S BRASS HG-4D-48SK K.E.C.PLUMBER YES -FIXED K57B 1 CONDIMENT RAIL CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K58 2 COUNTER TOP PLANCHA WOOD STONE WS-GPL-3636-CT01 K.E.C.K.E.C.YES -- K58A 2 GAS DISCONNECT HOSE (NOT SHOWN ON PLAN)T&S BRASS HG-4D-48SK K.E.C.PLUMBER YES -FIXED K58B 2 CONDIMENT RAIL CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K59 1 SHORTY REFRIGERATOR DELFIELD DA000A14P K.E.C K.E.C.YES -CASTERS K60 2 FRY WARMING STATION MERCO MCG1827NNN K.E.C.K.E.C.YES -- K63 1 48" HOT PLATE SOUTHBEND HDO-48 K.E.C.K.E.C.YES -- K63A 1 GAS DISCONNECT HOSE (NOT SHOWN ON PLAN)T&S BRASS HG-4D-48SK K.E.C.PLUMBER YES -FIXED K63B 1 CONDIMENT RAIL CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K64 1 SHORTY REFRIGERATOR DELFIELD DA000A13P K.E.C.K.E.C.YES -CASTERS K65 1 PAN/PLATE OVERSHELF CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K66 4 MICROWAVE OVEN PANASONIC NE-17521 K.E.C.K.E.C.YES -- K70.2 1 REACH-IN FREEZER DELFIELD 6125XL-S K.E.C.K.E.C.YES -CASTERS K71 2 REACH-IN REFRIGERATOR DELFIELD 6025XL-S K.E.C.K.E.C.YES -CASTERS K72A 1 FRY REFRIGERATOR DELFIELD 18648PTBMP K.E.C.K.E.C.YES -CASTERS K72B 1 DISH-UP REFRIGERATOR DELFIELD 18699PTBMP K.E.C.K.E.C.YES -CASTERS K72C 1 PIZZA PREP REFRIGERATOR DELFIELD DA000A?P01 K.E.C.K.E.C.YES -CASTERS K73 1 COUNTER TOP WARMER APW WYOTT W-9 K.E.C.K.E.C.YES -- K74 1 CONVEYOR TOASTER ANTUNES VCT-2 K.E.C.K.E.C.--- K74A 1 TOASTER COUNTER CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K75 1 WARMING DRAWER WELLS RWN-2 K.E.C.K.E.C.YES -- K76 1 CVAP HOLDING DRAWER WINSTON HBB0N2 K.E.C.K.E.C.YES -- K78 6 P.O.S SYSTEM UNITS - EXISTING - (2) TO RELOCATE --OWNER OWNER --- K79 1 DOUBLE WALL SHELF w/BOWL SLIDES & CONDIMENT RAIL CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K80 1 WORK COUNTER CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K80A 2 PLATE SHELVES CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K81A 3 PASS THRU CONDIMENT RAILS CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K81B 2 HEAT SHIELD CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K102 LOT WALL PANELING FOR MAIN COOK LINE CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES - K116A 1 PIZZA OVEN COUNTER CUSTOM S/S CUSTOM S/S K.E.C.K.E.C.YES YES FIXED K125 2 CONVECTION OVEN TURBO CHEF HHD-9500 -105-DL K.E.C.K.E.C.YES -- K141 6 POS MONITOR BRACKET - EXISTING - (2) TO RELOCATE PEERLESS SA730P OWNER OWNER --FIXED K143 3 HOT FOOD WELL APW WYOTT W-3VI K.E.C.K.E.C.YES -- SCALE: SHEET K2 MAIN KITCHEN 2 OF 5 SHEETS KI T C H E N E Q U I P M E N T P L A N , SC H E D U L E & E L E V A T I O N S DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A BYREVISIONS DRAWN: CHECKED: DATE: SCALE: ELEVATION "12" DISH-UP LINE EXISTING COLD WINDOW TO REMAIN ELEVATION "14" MAIN COOK LINE EXISTING PASS WINDOW TO REMAIN EXISTING PASS WINDOW TO REMAIN KITCHEN ELECTRICAL SCHEDULE ITEM #V/ɸ AMPS H.P.KW TYPE LOCATION A.F.F.NEMA REMARKS EDCO 120V/1 PH 15.0 EACH --D.C.O.WALL 48"5-20R CONVENIENCE OUTLET - (2) RIP'S E45 115V/1 PH 5.2 0.35 -D.C.O.WALL 24"5-15P UNDER COUNTER FREEZER - E.C. TO SUPPLY & INSTALL GFCI PROTECTED DUPLEX E49 115V/1 PH 4.7 0.25 -D.C.O.WALL 24"5-15P PIZZA STATION - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E49B 115V/1 PH 4.7 --D.C.O.WALL 24"5-15P SAUTE STATION - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E54 115V/1 PH 4.7 --D.C.O.WALL 24"5-15P BREADING STATION - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E55 120V/1 PH CONTROLS - 1.0, FILTER - 8.0 --QUAD WALL 24"5-20R FRYER ASSEMBLY w/FILTER - DEDICATED 20A CIRCUIT BREAKER E58 120V/1 PH .6 EACH --D.C.O.WALL 24"5-15P COUNTER TOP PLANCHA - (2) RIP'S E59 115V/1 PH 12.0 --D.C.O.WALL 24"5-15P SHORTY REFRIGERATOR - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E60 120V/1 PH 15.9 EACH - 1910 WATTS EACH D.C.O.WALL 48"5-20P FRY WARMING STATION - (2) RIP'S E64 115V/1 PH 2.9 --D.C.O.WALL 24"5-15P SHORTY REFRIGERATOR - E.C. TO SUPPLY & INSTALL GFCI PROTECTED DUPLEX E66 208V/1 PH 13.6 EACH - 1700 WATTS EACH S.P.O.WALL 72"6-20P MICROWAVE - (3) RIP'S E66A 208V/1 PH 13.6 -1700 WATTS S.P.O.WALL 72"6-20P MICROWAVE - REUSE EXISTING OUTLET E70.2 115V/1 PH 5.5 0.55 -D.C.O.WALL 72"5-15P REACH-IN FREEZER E71 115V/1 PH 4.2 0.22 -D.C.O.WALL 90"5-15P REACH-IN REFRIGERATOR - REUSE EXISTING OUTET E71A 115V/1 PH 4.2 0.22 -D.C.O.WALL 72"5-15P REACH-IN REFRIGERATOR E72A 115V/1 PH 4.7 --D.C.O.WALL 24"5-15P FRY REFRIGERATOR - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E72B 115V/1 PH 6.5 (2) 0.20 -D.C.O.WALL 24"5-15P DISH-UP REFRIGERATOR - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E72C 115V/1 PH 6.5 --D.C.O.WALL 24"5-15P PIZZA PREP REFRIGERATOR - E.C. TO PROVIDE & INSTALL GFCI PROTECTED DUPLEX E73 120V/1 PH 3.3 -400 WATTS D.C.O.WALL 48"5-15P COUNTER TOP WARMER E74 120V/1 PH 15.0 -1800 WATTS D.C.O./ JBOX WALL 52"5-15P CONVEYOR TOASTER - REUSE EXISTING OUTLET E75 120V/1 PH 7.5 -900 WATTS D.C.O.WALL 24"5-15P WARMING DRAWER - NARROW 2-TIER E76 120V/1 PH 12.0 -1440 WATTS D.C.O.WALL 24"5-15P CVAP HOLDING DRAWER E125 208V/3 PH 30.0 EACH -9600 WATTS S.P.O.WALL 48"15-30P CONVECTION OVEN - (2) RIP'S - E.C. INSTALL 4S BOX E143 120V/1 PH 10.0 EACH - 1200 WATTS EACH D.C.O.WALL 48"5-15P HOT FOOD WELL - (2) RIP'S E143A 120V/1 PH 10.0 -1200 WATTS D.C.O.WALL 24"5-15P HOT FOOD WELL KITCHEN POS ELECTRICAL SCHEDULE ITEM #V/ɸ AMPS TYPE LOCATION A.F.F.REMARKS KDS54A 120V/ 1 PH 20.0 D.C.O.WALL 66"KDS SYSTEM - DEDICATED CIRCUIT - VERIFY REQUIREMENTS w/OWNER KDS54B DATA JBOX WALL 66"DATA/KDS CABLE - 2" x 4" EMPTY BOX w/CONDUIT TO 6" ABOVE CEILING LINE - VERIFY REQUIREMENTS w/OWNER KDS64A 120V/ 1 PH 20.0 D.C.O.WALL 72"KDS SYSTEM - REUSE EXISTING OUTLET KDS64B DATA JBOX WALL 72"DATA/KDS CABLE - REUSE EXISTING OUTLET KDS72C 120V/ 1 PH 20.0 EACH D.C.O.WALL 86"KDS SYSTEM - DEDICATED CIRCUIT - VERIFY REQUIREMENTS w/OWNER KDS72D DATA JBOX WALL 86"DATA/KDS CABLE - 2" x 4" EMPTY BOX w/CONDUIT TO 6" ABOVE CEILING LINE - VERIFY REQUIREMENTS w/OWNER KDS72E 120V/ 1 PH 20.0 EACH D.C.O.WALL VARIES KDS SYSTEM - (4) RIP'S - REUSE EXISTING OUTLET KDS72F DATA VARIES WALL VARIES DATA/KDS CABLE - (4) RIP'S - REUSE EXISTING OUTLET ELECTRICAL SYMBOLS & ABBREVIATIONS SINGLE CONVENIENCE OUTLET (SCO)Sw SWITCH AS NOTED DOUBLE CONVENIENCE OUTLET (DCO)Sp SWITCH & PILOT LIGHT QUAD CONVENIENCE OUTLET (QCO)EL ELEVATION A.F.F JUNCTION BOX (JB)AMPS AMPERES HEATING ELEMENT OR POWER V VOLTS FLOOR RECEPTACLE AS NOTED ɸ PHASE SPECIAL PURPOSE OUTLET (SPO)A.F.F.ABOVE FINISHED FLOOR MOTOR OUTLET B.T.C.BRANCH TO CONNECTION POINT & CONNECT EQUIPMENT CONVENIENCE OUTLET - 2 CIRCUIT 120/280V - 1PH, 3 WIRE OR AS NOTED B.T.F.BRANCE TO FIXTURE, FURNISH & INSTALL RECEPTACLE CONDUIT AS NOTED D.F.A.DROP FROM ABOVE SOLENOID OR CONTROL CIRCUIT S.U.STUB UP A.F.F. DATA/PHONE H.P.HORSE POWER PANELBOARD KW KILOWATTS DISCONNECT SWITCH E.C.ELECTRICAL CONTRACTOR LIGHT INDICATION R.I.P.ROUGH IN POINT J C S D F R R +72" FS FS FSFSFSFSFSFS G FS FSFSFS +72"+72" +90"+52" A +52"+52" +84" +72" A +72"+72" A 3'- 8 " - E 1 2 5 6'- 2 " - E 1 2 5 8'- 6 " - E 4 9 13 ' - 8 " - E 7 5 , E 1 4 3 & E 6 6 20 ' - 3 " - E 7 2 C 25 ' - 1 " - E 7 2 A 32 ' - 5 1 / 2 " - E7 6 ( + 2 4 " ) & E7 4 ( E X I S T I N G ) 30 ' - 9 1 / 2 " - E 6 0 35 ' - 6 " - E 6 6 37 ' - 7 " - E 7 2 B E6 4 - 9 ' - 0 " E1 4 3 - 1 4 ' - 9 1 / 2 " E4 9 B - 1 3 ' - 0 " E6 6 - 1 0 ' - 7 1 / 2 " E7 1 A - 4 ' - 4 " E5 9 - 2 0 ' - 5 1 / 2 " E5 8 - 2 2 ' - 1 0 " E5 8 - 1 9 ' - 1 0 " E6 0 - 2 6 ' - 9 " E4 5 & E 7 3 - 2 6 ' - 1 " E5 5 - 3 0 ' - 4 1 / 2 " ED C O - 3 3 ' - 7 1 / 2 " E5 4 - 3 8 ' - 1 0 " E1 4 3 A - 3 8 ' - 4 " E7 0 . 2 - 4 0 ' - 6 " 43 ' - 6 3 / 4 " - ED C O ( + 4 8 " ) & E7 1 ( E X I S T I N G ) EX I S T I N G - E 6 6 A F R R +72"+72" +90"+90"+90" +90" +90"+90"+72"+72" KD S 7 2 D 17 ' - 2 1 / 2 " KD S 7 2 C 16 ' - 4 1 / 2 " KD S 7 2 E EX I S T I N G KD S 7 2 F EX I S T I N G KD S 7 2 F EX I S T I N G KD S 7 2 E EX I S T I N G KD S 7 2 E EX I S T I N G KD S 7 2 F EX I S T I N G KD S 7 2 E EX I S T I N G KD S 7 2 F EX I S T I N G KD S 6 4 A EX I S T I N G KD S 6 4 B EX I S T I N G D D KD S 5 4 B 33 ' - 2 1 / 8 " KD S 5 4 A 34 ' - 0 1 / 8 " SCALE: SHEET K5 3 OF 5 SHEETS REUSE AS MANY EXISTING UTILITIES AS POSSIBLE KI T C H E N E L E C T R I C A L / P O S P L A N , SC H E D U L E S & E L E V A T I O N S MAIN KITCHEN MAIN KITCHEN DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A BYREVISIONS DRAWN: CHECKED: DATE: SCALE: ELEVATION "12" DISH-UP LINE EXISTING COLD WINDOW TO REMAIN ELEVATION "14" MAIN COOK LINE EXISTING PASS WINDOW TO REMAIN EXISTING PASS WINDOW TO REMAIN REUSE EXISTING HAND SINK WATER & DRAIN EXISTING HAND SINK TO REMAIN GENERAL PLUMBING NOTES 1.ALL PLUMBING OUTLETS & CONNECTIONS SHOWN ON THIS PLAN ARE FOR FIXTURES & EQUIPMENT SHOWN RFG CONSULTING EQUIPMENT PLAN ONLY. FOR ADDITIONAL BUILDING REQUIREMENTS (AREA FLOOR DRAINS, ETC.) SEE OTHER DRAWINGS OR SPECIFICATIONS BY THE ARCHITECT 2.ALL DIMENSIONS ARE GIVEN FROM FINISHED WALL AND/OR CENTER LINE OF COLUMNS TO CENTER LINE OF OUTLET OR FROM CENTER LINE OF OUTLET TO CENTER LINE OF OUTLET, UNLESS OTHERWISE NOTED. ALL OUTLETS NOTED +12", +24", ETC. TO STUB OUT OF THE WALL AT HEIGHT GIVEN. HEIGHT OF OUTLETS IS GIVEN FROM FINISHED FLOOR (NOT TOP OF FINISHED CURB) TO CENTER LINE OF OUTLET. OUTLETS NOTED "STUB UP" OR "STUB OUT" ABOVE FINISHED FLOOR AT LOCATIONS SHOWN ARE TO STUB UP A MAXIMUM OF 4" ABOVE FINISHED FLOOR OR TOP OF CURB, UNLESS OTHERWISE NOTED. CONTRACTOR TO VERIFY ALL DIMENSIONS AT JOB SITE. 3.ALL FOR SINKS INDICATED HALF IN & HALF OUT OF COUNTER BODIES TO BE FLUSH w/FINISHED FLOOR. ALL FULLY OR PARTIALLY EXPOSED FLOOR SINKS TO BE PROVIDED w/APPROPRIATE GRATE COVERS. FLOOR SINKS HAVE BEEN LOCATED w/THE ASSUMPTION THAT THEY WILL BE SET FLUSH w/FINISHED FLOOR (UNLESS NOTED OTHERWISE.) IN THE EVENT LOCAL CODES REQUIRE FLOOR SINKS TO BE ABOVE OR BELOW FINISHED FLOOR LEVEL, PLUMBER SHALL COMPLY w/LOCAL CODES BUT NOTIFY REG CONSULTING IMMEDIATELY. 4.PLUMBER TO CONNECT ALL WATER LINES, GAS LINES, WASTE LINES, ETC., FOR SINK, DISHWASHERS, DISPOSERS, ETC., & RUN INSULATED DRAIN LINE FROM ALL REFRIGERATED UNITS, ICE PANS, ETC. TO FLOOR SINKS & DIRECT OR INDIRECT WASTE LINES TO BE NO SMALLER THAN STUB OUT OF FIXTURES THEMSELVES. 5.ALL WORK SHOWN ON FIXTURE PLUMBING PLAN & OUTLINED IN ABOVE NOTES TO BE PERFORMED BY PLUMBING CONTRACTOR UNDER BUILDING CONTRACT. IT IS THE PLUMBER'S RESPONSIBILITY TO SEE THAT THIS PHASE OF WORK MEETS, & IS INSTALLED IN ACCORDANCE w/STANDARDS REQUIRED BY ALL GENERAL, STATE & FEDERAL LAWS (INCLUDING HEALTH CODES), & BY ANY & ALL CODES PECULIAR TO THE MUNICIPALITY OR AREA WHERE JOB IS BEING INSTALLED. 6.THESE PLANS ARE FOR THE SOLE PURPOSE OF INDICATING THE LOCATION OF OUTLETS & EQUIPMENT REQUIREMENTS 7.PLUMBER TO PROVIDE THE FOLLOWING ITEMS: A.BALL VALVES ON ALL WATER & GAS LINES & SHOCK ABSORBERS ON ALL SELF VALVES B.ALL VALVES TRIM & PRESSURE REGULATORS NECESSARY TO CONNECT ALL LINES. C.TEMPERATURE & PRESSURE SAFETY RELEASE VALVES FOR HOT WATER BOOSTER IF USED. D.BACK FLOW PREVENTION DEVICES AS REQUIRED BY CODE. E.DIALECTIC COUPLERS WHEN CONNECTION GALVANIZED IRON PIPE TO COPPER. F.FLOOR SINK, FUNNEL HUBS, FLOOR DRAINS, & RESPECTIVE PROTECTIVE GRATES. G.NECESSARY WATER LINES & GAS LINES ON ROOF FOR MAKEUP AIR SYSTEM. FOR LOCATION & EXHAUST REQUIREMENTS, SEE ARCHITECTURAL AND/OR HVAC PLANS. H.ALL GRATES ON FLOOR SINKS & ALL SCREENS ON FLOOR DRAINS. I.ALL WATER FILTERS REQUIRED FOR ICE MACHINES, COFFEE MAKERS, STEAMERS, ETC. J.INDIVIDUAL BALL VALVE ON ALL DRAIN LINES FOR SOUP & FOOD WARMERS K.ALL DRAIN LINES, NOTE: DRAIN LINES SHALL BE RUN IN COPPER FROM CONNECTIONS TO TERMINATION. 8.PLUMBER TO MAKE ALL FINAL CONNECTIONS 9.PLUMBER TO INSTALL AUTOMATIC GAS SHUT-OFF VALVE SUPPLIED BY FIRE CONTROL CONTRACTOR 10.ALL DRAIN LINES FROM REFRIGERATED EQUIPMENT SHALL HAVE A "P" TRAP. THE "P" TRAP MUST BE LOCATED OUTSIDE OF THE REFRIGERATED CAVITY. 11.REFER TO REFRIGERATION DATA SHEET FOR ADDITIONAL PLUMBING NOTES & REQUIREMENTS. PLUMBING SYMBOLS & ABBREVIATIONS FLOOR DRAIN - 4" HIGH FUNNEL (FFD)S.R.STEAM RETURN FLOOR DRAIN - (FD)B.H.P.BOILER HORSEPOWER FLOOR SINK - AS NOTED - (FS)E.L.ELEVATION A.F.F RIGHT ANGLE FLOOR DRAIN - AS NOTED P.P.H.POUNDS PER HOUR MIXING HOSE BIB, SINGLE OUTLET P.S.I.POUNDS PER SQUARE INCH HOSE BIB, SINGLE OUTLET S.P.STATICE PRESSURE COLD WATER - (CW)A.F.F.ABOVE FINISHED FLOOR HOT WATER - (HW)B.T.C.BRANCH TO CONNECTION & CONNECT TEMPERED WATER B.F.F.BELOW FINISHED FLOOR DIRECT WATE D.F.A.DROP FROM ABOVE HUB DRAIN - (HD) - SET 1" A.F.F.S.U.STUB UP A.F.F. RETURN AIR DUCT CONNECTION W.G.INCHES OF WATER GAUGE EXHAUST DUCT CONNECTION C.F.M.CUBIC FEET PER MINUTE G.P.H.GALLONS PER HOUR F.P.M.FEET PER MINUTE ( VELOCITY) G.P.M.GALLONS PER MINUTE S.S.STEAM SUPPLY D.R.DRAIN R.I.P.ROUGH IN POINT K.E.C.KITCHEN EQUIPMENT CONTRACTOR P.C.PLUMBING CONTRACTOR KITCHEN GAS SCHEDULE ITEM # CONNECTION SIZE LOOKING UP OR DOWN B.T.U./ HOUR REMARKS USE EXISTING PIPE FOR NATURAL GAS LOOP TO HANDLE: 911,000 TOTAL B.T.U./HR.: G55 1"DOWN 357,000 FRYER ASSEMBLY w/FILTER - QUICK DISCONNECT SUPPLIED BY K.E.C. & INSTALLED BY P.C. G57 3/4"UP 120,000 36" CHARBROILER - P.C. TO INSTALL & SUPPLY GAS PRESSURE - QUICK DISCONNECT SUPPLIED BY K.E.C. & INSTALLED BY P.C. G58 3/4" EACH UP 85,000 EACH 36" PLANCHA - (2) RIP'S - QUICK DISCONNECT SUPPLIED BY K.E.C. & INSTALLED BY P.C. G63 3/4"UP 264,000 48" HOT TOP RANGE - GAS PRESSURE REGULATOR SUPPLIED w/UNIT & INSTALLED BY P.C. - QUICK DISCONNECT SUPPLIED BY K.E.C. & INSTALLED BY P.C. NOTE: THE GAS EQUIPMENT WILL BE INITIALLY SET BY THE K.E.C. THEN THE P.C. WILL USE EXISTING GAS LINE TO VARIOUS CONNECTION POINTS. P.C. IS TO PROVIDE SHUT-OFF'S & INSTALL ALL PRESSURE REGULATORS. P.C. IS TO INSTALL THESE COMPONENTS IN ACCESSIBLE AREAS FOR SERVICING. Gas Quick-Disconnect Installation NO SCALE 3" MAX. COOKING EQUIPMENT INSTALL GAS MANIFOLD TIGHT TO WALL w/1 5/8" UNISTRUT TO GAIN MAXIMUM EQUIPMENT DEPTH UNDER HOOD MAIN GAS MANIFOLD BY PLUMBER - MANIFOLD SECURED TO WALL SHUT-OFF VALVE BY PLUMBER GAS QUICK-DISCONNECT w/DOUBLE SWIVELS. DISCONNECT HOSE PROVIDED BY F.S.E.C.. INSTALLED BY PLUMBER BUILDING WALL MIN 1" (VERIFY CODES)ELBOWS & FITTINGS BY PLUMBER GAS CONNECTION ON COOKING EQUIPMENT GAS PRESSURE REGULATOR INSTALLED BY PLUMBER FINISHED FLOOR RESTRAINING CORD, SECURED TO WALL BLOCKING, STUD, OR GAS MANIFOLD BY PLUMBER. INCLUDED w/KIT. F R R G6 3 - 8 ' - 1 " G5 7 - 1 6 ' - 6 " G5 8 - 2 0 ' - 1 1 1 / 2 " G5 8 - 2 3 ' - 1 1 1 / 2 " G5 5 - 2 8 ' - 7 1 / 2 " REUSE EXISTING HAND SINK WATER & DRAIN EXISTING HAND SINK TO REMAIN REPLACE EXISTING FLOOR SINK GRATES TO FULL GRATES IN MAIN COOK LINE AND DISH UP LINE SCALE: SHEET K8 4 OF 5 SHEETS REUSE EXISTING GAS LOOP REUSE AS MANY EXISTING UTILITIES AS POSSIBLE KI T C H E N P L U M B I N G & G A S P L A N , SC H E D U L E S & E L E V A T I O N S MAIN KITCHEN DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A BYREVISIONS DRAWN: CHECKED: DATE: SCALE: ELEVATION "B" DISH-UP LINE ELEVATION "C" MAIN COOK LINE EXISTING COLD WINDOW TO REMAIN EXISTING PASS WINDOW TO REMAIN EXISTING PASS WINDOW TO REMAIN 6 24 "9 3.1 3.2 2'-3"9'-7"24" 46 " 33 " 27 " 4' - 1 0 " 36"41"6'-9 1/2" 6' - 8 " 5'-8 1/2" 33 " 46 " 3 1 24 " 48 " 24" WALL BACKING SCHEDULE NOTE: ARCHITECT TO DETERMINE TYPE OF WALL BACKING BASED ON LOCAL CODE REQUIREMENTS REFER TO ARCHITECT DRAWINGS FOR ADDITIONAL INFORMATION WALL BACKING IS FROM FINISHED WALLS ELEV. VIEW # ITEM #SIZE STARTING A.F.F.BY TYPE REMARKS KITCHEN: B 1 24" x 48"24"G.C.16 GA. GALVANIZED STEEL HAND SINK B 3 6'-9 1/2" x 33"46"G.C.16 GA. GALVANIZED STEEL MICROWAVE & WALL SHELVES B 3.1 24" x 33"46"G.C.16 GA. GALVANIZED STEEL MICROWAVE WALL SHELF B 3.2 9'-7" x 27" TOP OF PASS WINDOW (4'-10") G.C.16 GA. GALVANIZED STEEL WALL SHELVES C 6 FULL WIDTH FULL HEIGHT G.C.16 GA. GALVANIZED STEEL COOK LINE B 9 36" x 24" TOP OF PASS WINDOW (6'-8") G.C.16 GA. GALVANIZED STEET POS MONITOR @ DISH-UP LINE F R R 33.2 93.1 6 K13B K13C 2'-3"41"5'-8 1/2" 1 SCALE: SHEET K13 5 OF 5 SHEETS REUSE AS MANY EXISTING UTILITIES AS POSSIBLE KI T C H E N C R I T I C A L P L A N , SC H E D U L E & E L E V A T I O N S MAIN KITCHEN DA V E & B U S T E R ' S SA N T A A N I T A , C A 40 0 S o u t h B a l d w i n A v e n u e , A r c a d i a , C A BYREVISIONS DRAWN: CHECKED: DATE: SCALE: WWW.PUBLICHEALTH.LACOUNTY.GOV/EH SPECIALIZED SURVEILLANCE AND ENFORCEMENT BRANCH ENVIRONMENTAL HEALTH DEPARTMENT OF PUBLIC HEALTHwCOUNTY OF LOS ANGELES PLAN CHECK PROGRAM - BALDWIN PARK 5050 COMMERCE DR, BALDWIN PARK, CA 91706 PHONE: (626) 430-5560 OFFICIAL PLAN REVIEW REPORT 03/05/2025DATE EHS VICKI NGO PLAN CHECK NUMBER SR0397249 PROGRAM ELEMENT 1702 - RESTAURANT (501-1,999 SF) -RMDL OWNER / REQUESTER JASON COX, SR DIR OF MAINTENANCE DBA DAVE & BUSTER'S ADDRESS 400 S BALDWIN AVE #930U, ARCADIA, CA 91007 REVISED PLAN REVIEW STATUS: APPROVED CORRECTIONS COMPLETED DATE CORRECTEDCORRECTION CATEGORY DATE IDENTIFIED 03/05/2025WATER SUPPLY 01/16/2025 03/05/2025WASTE WATER/PLUMBING 01/16/2025 03/05/2025EQUIPMENT/STORAGE 01/16/2025 03/05/2025VENTILATION01/16/2025 03/05/2025PLAN SUBMITTAL/REMODEL 01/16/2025 ADDITIONAL REQUIREMENTS NONE Help us serve you better by completing a short survey. Visit our website at www.publichealth.lacounty.gov/eh. Page 1 of 3EHS Signature OFFICIAL PLAN REVIEW REPORT 03/05/2025DATE EHS VICKI NGO PLAN CHECK NUMBER SR0397249 PROGRAM ELEMENT 1702 - RESTAURANT (501-1,999 SF) -RMDL OWNER / REQUESTER JASON COX, SR DIR OF MAINTENANCE DBA DAVE & BUSTER'S ADDRESS 400 S BALDWIN AVE #930U, ARCADIA, CA 91007 COMMENTS PLAN IS APPROVED. REMODEL SCOPE OF WORK INCLUDES REPLACING EQUIPMENT AND ADDING EQUIPMENT. NO CHANGES IN PLUMBING. FINAL FACILITY APPROVAL IS CONTINGENT UPON THE ON SITE INSPECTION AND APPROVAL OF THE FOOD EQUIPMENT AND THE PREMISES. CONTACT VICKI NGO AT 626-430-5557 OR VINGO@PH.LACOUNTY.GOV TO SCHEDULE AN APPOINTMENT FOR FINAL FIELD INSPECTION. CALL AT LEAST 3 TO 5 WORKING DAYS PRIOR TO ARRANGE FOR A FINAL INSPECTION. A FINAL INSPECTION SHALL BE CONDUCTED AND A PUBLIC HEALTH PERMIT OBTAINED PRIOR TO OPENING AND OPERATING THIS FOOD ESTABLISHMENT. THE FOLLOWING MUST BE COMPLIED WITH PRIOR TO CALLING FOR A FINAL INSPECTION: 1. ALL BUILDING AND SAFETY (MECHANICAL, PLUMBING, ELECTRICAL AND FIRE) AND OTHER ENFORCEMENT AGENCIES FINAL INSPECTIONS MUST BE SIGNED OFF PRIOR TO HEALTH DEPARTMENT FINAL APPROVAL IF NEEDED. 2. THE HEALTH DEPARTMENT APPROVED PLANS MUST BE AVAILABLE AT THE JOB SITE AT THE TIME OF INSPECTION. 3. ALL UTILITIES MUST BE ON AND OPERATIONAL. HOT WATER MUST BE AT 120F AND ABOVE. ALL REFRIGERATION UNITS MUST BE 41F AND BELOW. EXHAUST FAN MUST BE OPERATIONAL. 4. ALL FOOD AND UTENSIL RELATED EQUIPMENT SHALL HAVE AN ANSI CERTIFICATION. IF CONSTRUCTION IS NOT COMPLETED WITHIN TWELVE (12) MONTHS FROM THE DATE OF APPROVAL, NEW PLAN SUBMISSION AND APPROVAL SHALL BE REQUIRED. ONE SET OF HEALTH DEPARTMENT APPROVED PLANS SHALL BE ON THE JOB SITE AT ALL TIMES DURING CONSTRUCTION. ANY CHANGES TO THE APPROVED PLANS MUST BE BROUGHT TO THE PLAN CHECKERS ATTENTION Help us serve you better by completing a short survey. Visit our website at www.publichealth.lacounty.gov/eh. Page 2 of 3EHS Signature OFFICIAL PLAN REVIEW REPORT 03/05/2025DATE EHS VICKI NGO PLAN CHECK NUMBER SR0397249 PROGRAM ELEMENT 1702 - RESTAURANT (501-1,999 SF) -RMDL OWNER / REQUESTER JASON COX, SR DIR OF MAINTENANCE DBA DAVE & BUSTER'S ADDRESS 400 S BALDWIN AVE #930U, ARCADIA, CA 91007 DISCLOSURES Prior to construction and approval from the Los Angeles County Department of Public Health Environmental Health Division (DPH-EH) Plan Check Program, final inspections must be obtained from Building and Safety (mechanical, plumbing, electrical) and all other enforcement agencies. Failure to obtain a Public Health Permit/ License prior to operation of the facility/establishment is a misdemeanor violation. Construction of the food facility/ establishment must be completed and approved within twelve (12) months from the date of approval to avoid submitting new plans. A copy of the approved plans must be available at the time of the field construction review. All utilities must be on and operational at the time of the field construction review. Please contact your plan check inspector at least 3 days prior to the field construction review. Two field inspections will be covered under the Plan Check fees assessed upon plan submission. A charge will be assessed for each subsequent field construction review. Help us serve you better by completing a short survey. Visit our website at www.publichealth.lacounty.gov/eh. Page 3 of 3EHS Signature