HomeMy WebLinkAbout815 W Naomi Ave - 2025 - DLHOPE SalonSHEET TITLE: STAMP: PROJECT ADDRESS: SHEET NUMBER 1040 S Otterbein Ave, Suite# B Rowland Heights, CA 91748 Phone: 909.569.2069 EMail: cnd9@icloud.com COMMERCIAL RESIDENTIAL INTERIOR DESIGNiDEAL GROUP, Inc. DESIGN De s i g n I n c , . 1 2 3 . COVER SHEET DL H O P E V R H A I R S A L O N 81 5 W N A O M I A V E U N I T # G AR C A D I A C A 9 1 0 0 7 PROJECT SUMMARY SHEET INDEX CONTRACTOR NOTES DLHOPE VR HAIR SALON FIRE PREVENTION NOTES 1.BEFORE SUBMITTING THE BID, THE CONTRACTOR SHALL CAREFULLY EXAMINE THE PLANS PERTAININGTO THIS WORK, CONTRACTOR SHALL VISIT THE SITE AND FULLY INFORM HIMSELF AS TO ALL CONDITIONSAND LIMITATIONS APPLYING TO THIS WORK HE SHALL ESTIMATE AND INCLUDE IN HIS BID A SUMSUFFICIENT TO COVER THE COST OF ALL LABOR AND MATERIALS TO ACCOMPLISH THE INTENT OF THESEPLANS. 2. THE CONTRACTOR SHALL 0BTAIN PERMITS AS REQUIRED BY THE GOVERNlNG AUTHORITIES FORCONSTRUCTION. 3. ELECTRICAL, MECHANICAL AND PLUMBING SYSTEMS SHALL BE DONE BY THE CONTRACTOR. 4. THE CONTRACTOR SHALL PROCURE IN THE OWNER'S NAME, AND CHARGES FOR INSTALLATION OF THEWATER AND GAS METERS AND ALL PIPING FROM MAIN TO MAID METERS. 5. THE CONTRACTOR SHALL SENT PROPER NOTICES. MAKE ALL NECESSARY ARRANGMENTS AND PERFORMALL SERVICES REQUIRED IN THE MAINTENANCE OF ALL PUBLIC UTILITIES 6. THE CONTRACTOR SHALL REQUIRE SUCH COOPERATION OF THE VARIOUS TRADES AS WILL BENECESSARY TO COMPLETE EACH AND EVERY PART OF THE WORK. EVEN THOUGHOUT SPECIFICALLYINDICATED. NOTED OR DETAILED ON THE DRAWINGSOR SPECIFICATIONS. 7. DIMENSIONS AND CONDITIONS AT THE JOBSITE SHALL BE VERIFIED BY( THE CONTRACTORS.DISCREPANCIES IN THE DRAWINGS OR BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS ORCODE REQUIREMENTS SHALL BE REPORTED TO THE ARCHITECT. CORRECTED DRAWINGS OR INSTRUCTIONSSHALL BE ISSUED By THE ARCHITECT PRIOR TO THE INSTALLATION OF ANY WORK SITE PLAN 1 2 4 5 6 9 3VICINITY MAP T-0 COVER SHEET A-1 FLOOR PLAN HD-1 H.C DETAIL E-1 POWER PLANE-2 CEILING PLAN A-2 EX CEILING PLAN 6.) EXTERIOR SIGN, UNDER SEPARATE PERMIT . 7.) MAX. EMPLOYEES INCLUDING MANAGER PER SHIFT 4 5. ) CODE APPLIED: 2022 CA BUILDING CODE (22 CBC), 2022 CALIFORNIA PLUMBING CODE (22 CPC), 2022 CALIFORNIA MECHANICAL CODE (22 CMC), 2022 CALIFORNIA FIRE CODE (22 CFC) 2022 CALIFORNIA ELECTRICAL CODE (22 CEC) ACCESSIBILITY SIGN DETAIL 10 " M I N OCCURS. 70" SQ. REFLECTORIZED EQUAL ON BLUE STEEL PIPE. CAP TUBE END 2" DIA. GALV. TUBULAR BACKGROUND. WHERE WHITE BEADED TEXT OR VAN ACCESSIBLE SIGN WITH BE WHITE ON HANDICAPPED BLUE BACKGROUND SIGN. WHEEL CHAIR SHALL CONCRETE FOOTING 1'-8" VAN ACCESSIBLE 1'-0 FINSH GRADE / PAVEMENT 6' - 8 " 30 " M I N 3" MIN COVER REQUIRED SCOPE OF WORK 7 T. I EXISTING V.R. HAIR SALON CHANGE TO DLHOPE HAIR SALON CONSULTANT INFORMATION DESIGNER : KEN FANG 21671 GATEWAY CENTER DR #201 DIAMOND BAR CA 91765 TEL: 909-569-2069 8 T-0 OCCUPANT LOAD 21 PERSONS E SN T A T S ECIL T IA FO CA L I F O R N A IHCERD T C E E SN T A T S ECIL T IA FO CA L I F O R N A IHCERD T C E REPLACE EXISTING SHAMPOO BED, MIRROR AND FURNITURE To preserve the integrity of the existing plumbing system serving the Premises (and the building wherein the Premises is situated), any plumbing work that is required as a result of Tenant's improvements, including, without limitation, the installation of any backflow device (including a protective cage over said device), shall be coordinated with and completed by Landlord's plumber (at Tenant's sole cost), whose contact information follows. Name: Gevork "George" Karavaev COMPANY: GO GREEN PLUMBING E-MAIL: GOGREEN.GK@GMAIL.COM TEL: 818-683-3010 To preserve the existing roof warranty, any roof-related work, or penetrations to and sealing of the roof, that is required as a result of Tenant's improvements, including, without limitation, removal of any existing equipment on the roof or installation of any new equipment on the roof, shall be coordinated with and completed by Landlord's roofer (at Tenant's sole cost), whose contact information follows. Chris Ekkelboom Mantra Roofing and Constructions chris@mantraroofingandconstruction.com 916-998-8899 Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official.” OWNER: DLHOPE VR HAIR SALON LLC 815 W NAOMI AVE UNIT# H ARCADIA,CA 91007 PHONE: 626-321-3484 EMAIL: DLHOPEVRHAIR@GMAIL .COM REPAINTING , CHANGE TILES FLOOR EXISTING LIGHTING FIXTURE REMAIN , NO CHANGE REPLACE SOME OF "T" BAR CELING PROJECT HERE Accessible path of travel: 48 in minimum width walkway, 5% maximum slope in the direction of travel, 2% maximum cross-slope. (CBC Section 11 B-403.3) & (CBC Section 11 B-403.5) The running slope of accessible path of travel shall not be steeper than 1 :20 (5%). The cross slope of walking surfaces shall not be steeper than 1 :48 (2.083%). [11 B-403.3] 8' - 0 " 9' - 0 " 9' - 0 " 18'-0" EX H.C PARKING SPACE 1 THAT INSPECTOR IS VERIFY EXISTING PATH OF TRAVEL 1 Planning will approve plans once all business license required items are provided/addressed, Contact the Business License Division at 626-574-5430 EX P N L"A" EX UNISEX RESTROOM EX B R E A K R O O M D W EX I T EX I T EX I T EX I T EX SHAMPOO AREA EX CASHIER AREA EX WAITING AREA EX HAIR CUT AREA EX DRY HAIR AREA EX P N L"A" EX UNISEX RESTROOM EX B R E A K R O O M D W EX I T EX I T EX I T EX I T EX SHAMPOO AREA EX CASHIER AREA EX WAITING AREA EX HAIR CUT AREA EX SKIN CARE ROOM EX OFFICE PROPOSED FLOOR PLAN DL H O P E V R H A I R S A L O N 81 5 W N A O M I A V E U N I T # G AR C A D I A C A 9 1 0 0 7 E SN T A T S ECIL T IA FO CA L I F O R N A IHCERD T C E E SN T A T S ECIL T IA FO CA L I F O R N A IHCERD T C E SHEET TITLE: STAMP: PROJECT ADDRESS: SHEET NUMBER 1040 S Otterbein Ave, Suite# B Rowland Heights, CA 91748 Phone: 909.569.2069 EMail: cnd9@icloud.com COMMERCIAL RESIDENTIAL INTERIOR DESIGNiDEAL GROUP, Inc. DESIGN De s i g n I n c , . 1 2 3 . A-1 A portion of the counter surface that is 36 inches long minimum and 34 inches high maximum above the finish floor shall be provided. A clear floor or ground 118-904.4.2 Forward Approach. A portion of the counter surface that is 36 inches long minimum and 34 inches high maximum shall be provided. Knee and toe space complying with 118-306 (Knee and Toe Clearance) shall be provided under the counter. A clear floor or ground space complying with 118-305 (Clear Floor or Ground Space) shall be positioned for a forward approach to the counter. EXCEPTION: Where the provided counter surface is less than 36 inches long, the entire counter surface shall be 34 inches high maximum above the finish floor. CBC 2013 118-904.1 ROOM FINISH SCHEDULE MATERIALS NOTES: FINISH SCHEDULE NOTES: D1 D2 1 2 DOORS SCHEDULE "Wall and ceiling materials shall not exceed the flame spread classifications in CBC Table 803.9." CONSTANT LATCHING FLUSH BOLTS-METAL DOORS ( "IVES" MODEL# FB50 SERIES ) CONSTANT LATCHING FLUSH BOLTS-WOOD DOORS ( "IVES" MODEL# FB60 SERIES ) DUST PROOF STRIKES (MODEL# DP1 AND DP2 ) "IVES" MODEL# FB60 SERIES DOOR SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, OR SPECIAL KNOWLEDGE OR EFFORT CBC SEC 1008.1.9 DOOR PANIC HARDWARE NOTE: 2 PIECE VERTICAL RODS RON DUPRIN, JACKSON OR EQUAL, PUSH BAR MUST BE OFFSET FROM DRS EDGE. THAT ALL FINISHES SHALL COMPLY WITH CBC CHAP. 8, TABLE 803.9. INTERIOR FLOOR FINISHES SHALL COMPLY WITH SECTION 804. LEVER HARDWARE EGRESS TRAVEL 84 FT (MAX DISTANT 300 FT WITH SPRINKLER 19" MIN 4 D3 A minimum of one 2A 10-S:C shall be provided on each floor level, conspicuously located, along normal paths of travel and within 75 feet travel distance. (CCR, Title 19, Division 1, Section 568, TABLE 2 OCCUPANCY LOADAREA CASHIER /WAITING AREA SECTION TOTAL 110sq. ft. 21 PERSONS HAIR CUT/HAIR WASH 744 sq. ft. 1477sq. ft. RESTROOM/HALL WAY AREA 546 sq. ft. O.L=110/15= 7 PERSON 3 O.L = 744/150=5 PERSON Table 1004.5 of the 2022 CBC O.L = 546/150=4 PERSON BREAK ROOM AREA 77 sq. ft.O.L = 77/15=5 PERSON 7'-0" 80'-7" 7' - 8 " 3'-2" 5'- 0 " 3'-5" 77'-0" 3' - 2 " 3' - 0 " 18 ' - 6 " ALL ARE EXISTING WALL, NO CHANGE. WALL LEGEND: PROPOSED FLOOR PLAN N AREA: 53 S.F AR E A : 7 7 S . F AREA: 151 S.F AREA: 72 S.F AREA: 38 S.F 5'-4"67'-3" 3' - 9 " 8' - 3 " 6' - 5 " 18 ' - 6 " 3' - 5 " D3 D2 D1 3' - 0 " 4' x 4 ' C L R 5' x 5 ' C L R ■ ■ ■TOILET ROOM SHALL BE PROVIDED OPENABLE A VERTICAL DUCT NOT LESS THAN 100 SQUARE INCHES IN AREA FOR THE FIRST WATER CLOSET PLUS 50 SQUARE INCHES ADDITIONAL WATER CLOSET . PROVIDING A COMPLETE CHANGE OF AIR EVEY 15 MINUTES. ■ NOTE: THE REST ROOM FLOORS SHALL HAVE A SMOOTH, HARD,NONABSORBENT SURFACE THAT EXTENDS UPWARD ONTO THE WALLS AT LEAST 6 INCHES(152MM) [CBC 1210.1] TOILET ROOMS MUST BE VENTED TO THE OUTSIDE AIR BY MEANS OF AN OPENABLE, SCREENEDWINDOW (NOT LESS THEN 16 MESH SCREENING),AN AIR SHAFT,OR A LIGHT-SWITCH-ACTIVATEDEXHAUST FAN. AREA: 593 S.F fire extinguisher PROVIDE AT LEAST 36" LONG COUNTER AT CASH REGISTER THAT BETWEEN 28" TO 34" ABOVE FINISHED FLOOR PER CBC11B-904.4.1 service counter complies with CBC, Section 904.4 for parallel approach or forward approach. (CBC, Sec. 11B-227.3). PATH OF EGRESS TRAVEL DISTANCE =84-0" EXISTING FLOOR PLAN N REMOVED NON-BEARING WALL EX I T EX I T EX I T EX I T CEILING PLAN DL H O P E V R H A I R S A L O N 81 5 W N A O M I A V E U N I T # G AR C A D I A C A 9 1 0 0 7 SHEET TITLE: STAMP: PROJECT ADDRESS: SHEET NUMBER 1040 S Otterbein Ave, Suite# B Rowland Heights, CA 91748 Phone: 909.569.2069 EMail: cnd9@icloud.com COMMERCIAL RESIDENTIAL INTERIOR DESIGNiDEAL GROUP, Inc. DESIGN De s i g n I n c , . 1 2 3 . A-2 E SN TA T S ECIL T IA FO CA LI F O R N A IHCERD T C E E SN T A T S ECIL T IA FO CA LI F O R N A IHCERD T C E LEGEND: EXHAUST FAN MIN 75 CFM NOTE: EX SUPPLY A/C OUTLET EX RETURN A/C OUTLET EXIT he suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7-16 Section 13.5.6.2.2 as follows: a.The width of the perimeter supporting closure angle or channel shall be not less than 2.0 in. unless qualified perimeter supporting clips are used. b.Closure angles or channels shall be screwed or otherwise positively attached to wall studs or other supporting structures. Perimeter supporting clips shall be qualified in accordance with approved test criteria per Section 13.2.5. c.Perimeter supporting clips shall be attached to supporting closure angle or channel with a minimum of two screws per clip and shall be installed around the entire ceiling perimeter. d.In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle, channel, or perimeter supporting clip. The other end of the ceiling gird in each horizontal direction shall have a minimum 0.75-in clearance from the wall and shall rest upon and be free to slide on a closure angle, channel, or perimeter supporting clip. e.Ceiling areas over 2500 ft.² must have seismic separation joints or full height partitions. f.Ceilings without rigid bracing must have 2” oversize trim rings for sprinklers and other ceiling penetrations. EXISTING REFLECTED CEILENG PLAN EXISTING LIGHTING FIXTURES REMAIN NOCHANGE NO MODIFICATIONS TITLE 24 LIGHTING FIXTURE SCHEDULE EMERGENCY LTG EMERGENCY LTG EX EX EX EX EX EX EXEXEXEXEX EX EX EXEX EX EX EX EX EXEX EX EX EX EX EX EX EX EX EXEXEX EX EX EX DRYWALLCEILING AFF +8'-" S LIGHT SWITCH WILL ACTIVATE THE MECHANICAL EXHAUST FAN EX T-BAR CEILING HEIGHTAFF +11'-" EX T-BAR CEILING HEIGHTAFF +11'-" EX T-BAR CEILING HEIGHTAFF +11'-" EX T-BAR CEILING HEIGHTAFF +11'-" EX T-BAR CEILING HEIGHTAFF +11'-" EX T-BAR CEILING HEIGHTAFF +11'-" EX T-BAR CEILING HEIGHTAFF +11'-" REPLACE "T" BAR PANEL SHEET TITLE: STAMP: PROJECT ADDRESS: SHEET NUMBER 1040 S Otterbein Ave, Suite# B Rowland Heights, CA 91748 Phone: 909.569.2069 EMail: cnd9@icloud.com COMMERCIAL RESIDENTIAL INTERIOR DESIGNiDEAL GROUP, Inc. DESIGN De s i g n I n c , . 1 2 3 . SIGNAGE SC: N.T.S2 H/C SIGN SC: N.T.S.3 H/C TOILET SC: N.T.S.4 H/C TOILET SC: N.T.S.5H/C LAV. ENTRANCE SIGN SC: N.T.S. SC: N.T.S. SC: N.T.S. 10 8 7 TOILET ACCESS. GRAB BARS H/C URINALS SC: N.T.S. SC: N.T.S. SC: N.T.S. 15 13 12 THRESHOLDSSC: N.T.S.20SC: N.T.S.25SC: N.T.S.30 FLOORS SC: N.T.S.23 DOORS & DOOR HARDWARESC: N.T.S.24 BRAILLE SIGNSC: N.T.S.18 234 WEST STAIR NO ROOF ACCESS B2 THROUGH 12 M1 6B2 THROUGH 12 NO ROOF ACCESSWEST STAIR 1 THROUGH 12 STAIR 3 6 ROOF ACCESS H/C D.F.SC: N.T.S.17SC: N.T.S.22DOOR SIGNAGE WALKS, HAZARDS, PORTRUDING OBJECTS 11B-6H/C TOILET 19 " M I N 48 " M I N 24 " 12 " M A X . 1'-6"2'-8" 1'-6"17"-18" ALL DISPENSERS 40" MAX TO HEIGHT OPERABLE PART 12" MIN 111 B -703.2 RAISED CHARACTERS. RAISED CHARACTERS SHALL COMPLYWITH SECTION 11 B-703.2 AND SHALL BE DUPLICATED IN BRAILLECOMPLYING WITH SECTION 11 B-703.3. RAISED CHARACTERS SHALLBE INSTALLED IN ACCORDANCE WITH SECTION 11 B-703.4.IIB-703.2.1 DEPTH. RAISED CHARACTERS SHALL BE 1/32 INCH(0.8 MM) MINIMUM ABOVE THEIR BACKGROUND.IIB-703.2.2 CASE. CHARACTERS SHALL BE UPPERCASE.11 B-703.2.3 STYLE. CHARACTERS SHALL BE SANS SERIF. CHARACTERSSHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OROF OTHER UNUSUAL FORMS.11 B-703.2.4 CHARACTER PROPORTIONS. CHARACTERS SHALL BESELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER"0" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OFTHE HEIGHT OF THE UPPERCASE LETTER "I". IIB-703.2.5 CHARACTER HEIGHT. CHARACTER HEIGHT MEASUREDVERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE5/8 INCH (15.9 MM) MINIMUM AND 2 INCHES (51 MM) MAXIMUMBASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". IIB-703.2.6 STROKE THICKNESS. STROKE THICKNESS OF THEUPPERCASE LETTER "I" SHALL BE 15 PERCENT MAXIMUM OF THEHEIGHT OF THE CHARACTER.11 B-703.2. 7 CHARACTER SPACING. CHARACTER SPACING SHALLBE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENTRAISED CHARACTERS WITHIN A MESSAGE, EXCLUDING WORDSPACES. WHERE CHARACTERS HAVE RECTANGULAR CROSS SECTIONS,SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8INCH (3.2 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTERSTROKE WIDTH MAXIMUM. WHERE CHARACTERS HAVE OTHER CROSSSECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERSSHALL BE '/16 INCH (1.6 MM) MINIMUM AND 4 TIMES THE RAISEDCHARACTER STROKE WIDTH MAXIMUM AT THE BASE OF THE CROSSSECTIONS, AND 1/8 INCH (3 .2 MM) MINIMUM AND 4 TIMES THERAISED CHARACTER STROKE WIDTH MAXIMUM AT THE TOP OF THECROSS SECTIONS. CHARACTERS SHALL BE SEPARATED FROM RAISEDBORDERS AND DECORATIVE ELEMENTS \ INCH (9.5 MM) MINIMUM.IIB-703.2.8 LINE SPACING. SPACING BETWEEN THE BASELINESOF SEPARATE LINES OF RAISED CHARACTERS WITHIN A MESSAGESHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUMOF THE RAISED CHARACTER HEIGHT.IIB-703.2.9 FORMAT. TEXT SHALL BE IN A HORIZONTALFORMAT.IIB-703.3 BRAILLE. BRAILLE SHALL BE CONTRACTED (GRADE 2) ANDSHALL COMPLY WITH SECTIONS 11 B-703.3 AND 11 B-703.4.IIB-703.3.1 DIMENSIONS AND CAPITALIZATION. BRAILLE DOTSSHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLYWITH TABLE 11 B-703.3.1. THE INDICATION OF AN UPPERCASELETTER OR LETTERS SHALL ONLY BE USED BEFORE THE FIRST WORD OFSENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OFTHE ALPHABET, INITIALS, AND ACRONYMS.11B-703.3.2 POSITION. BRAILLE SHALL BE POSITIONED BELOWTHE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT ORCENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACEDBE10W THE ENTIRE TEXT. BRAILLE SHALL BE SEPARATED 3/8 INCH(9.5 MM) MINIMUM AND 1/2 INCH (12.7 MM) MAXIMUM FROMANY OTHER TACTILE CHARACTERS AND 3/8 INCH (9.5 MM) MINIMUMFROM RAISED BORDERS AND DECORATIVE ELEMENTS. EXCEPTION: BRAILLE PROVIDED ON ELEVATOR CAR CONTROLSSHALL BE SEPARATED 3/16 INCH (4.8 MM) MINIMUM ANDSHALL BE LOCATED EITHER DIRECTLY BELOW THE CORRESPONDINGRAISED CHARACTERS OR SYMBOLS. 11B-703.4 INSTALLATION HEIGHT AND LOCATION. SIGNS WITH TACTILECHARACTERS SHALL COMPLY WITH SECTION 11B-703.4. 11B-703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND. TACTILECHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES (1219MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE,MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND60 INCHES (1524 MM) MAXIMUM ABOVE THE FINISH 1100R ORGROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHESTLINE OF RAISED CHARACTERS.EXCEPTION: TACTILE CHARACTERS FOR ELEVATOR CAR CONTROLSSHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11 B-703.4.1. 11B-703.4.2 LOCATION. WHERE A TACTILE SIGN IS PROVIDED ATA DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THELATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORSWITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVELEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORSWITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHTOF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THELATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLEDOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL.SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THATA DEAR FLOOR SPACE OF 18 INCHES (457 MM) MINIMUM BY 18INCHES (457 MM) MINIMUM, CENTERED ON THE TACTILE CHARACTERS,IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEENTHE CLOSED POSITION AND 45 DEGREE OPEN POSITION. WHEREPERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMSAND SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE OFTHE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFYEXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOORAS ONE EXITS THE ROOM OR SPACE.11B·703.S VISUAL CHARACTERS. VISUAL CHARACTERS SHALL COMPLYWITH SECTION 11B-703.5.EXCEPTION: WHERE VISUAL CHARACTERS COMPLY WITH SECTION11B-703.2 AND ARE ACCOMPANIED BY BRAILLE COMPLYINGWITH SECTION LLB-703.3, THEY SHALL NOT BE REQUIRED TO COMPLYWITH SECTIONS LLB-703.5.2 THROUGH 11B-703.5.6, 11B-703.5.8 AND 11B-703.5.9.11B-703.S.1 FINISH AND CONTRAST. CHARACTERS AND THEIRBACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALLCONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERSON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.11B-703.S.2 CASE. CHARACTERS SHALL BE UPPERCASE OR LOWERCASEOR A COMBINATION OF BOTH.11B-703.S.3 STYLE. CHARACTERS SHALL BE CONVENTIONAL INFORM. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLYDECORATIVE, OR OF OTHER UNUSUAL FORMS.11B-703.S.4 CHARACTER PROPORTIONS. CHARACTERS SHALL BESELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER"0" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OFTHE HEIGHT OF THE UPPERCASE LETTER "J".11B-703.S.S CHARACTER HEIGHT. MINIMUM CHARACTERHEIGHT SHALL COMPLY WITH TABLE 11 B-703.S.5. VIEWING DISTANCESHALL BE MEASURED AS THE HORIZONTAL DISTANCE BETWEENTHE CHARACTER AND AN OBSTRUCTION PREVENTING FURTHERAPPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE BASEDON THE UPPERCASE LETTER "I". EXCEPTION: WHERE PROVIDED, FLOOR PLANS PROVIDINGEMERGENCY PROCEDURES INFORMATION IN ACCORDANCE WITHTITLE 19 SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 11B-703.5.5. 11 B-703.S.6 HEIGHT FROM FINISH FLOOR OR GROUND. VISUALCHARACTERS SHALL BE 40 INCHES (1016 MM) MINIMUM ABOVETHE FINISH FLOOR OR GROUND. IIB-703.7.2.1 INTERNATIONALSYMBOL OF ACCESSIBILITY.THE INTERNATIONAL SYMBOL OFACCESSIBILITY SHALL COMPLYWITH FIGURE 11B-703.7.2.1. THESYMBOL SHALL CONSIST OFA WHITE FIGURE ON A BLUEBACKGROUND. THE BLUE SHALL BECOLOR NO. 15090 IN FEDERALSTANDARD 595B. EXCEPTION: THE APPROPRIATEENFORCEMENT AGENCYMAY APPROVE OTHER COLORS TOCOMPLEMENT DECOR ORUNIQUE DESIGN. THE SYMBOLCONTRAST SHALL BE LIGHT ONDARK OR DARK ON LIGHT.IIB-703.7.1 FINISH AND CONTRAST.SYMBOLS OF ACCESSIBILITYAND THEIR BACKGROUND SHALLHAVE A NON-GLARE FINISH.SYMBOLS OF ACCESSIBILITY SHALLCONTRAST WITH THEIRBACKGROUND WITH EITHER ALIGHT SYMBOL ON A DARKBACKGROUND OR A DARKSYMBOL ON A LIGHTBACKGROUND. 24" MIN 1 HD-1 HANDICAPED DETAIL 18 " 33 54 " M I N 9" M I N 27 " M I N 29 " M I N 34 " M A X 40 " M A X 5'-0"MIN 6"MAX8"MIN 17"MIN 60 " 8"MIN 6"MAX 9" M I N 27 " M I N 36 " M A X 54"MIN 12"MAX 8" 8" 5' - 0 " 1'-0" 2'-0"MIN 18 " 24"MIN 7"-9 33 " - 3 6 " 17"-18" 33 " - 3 6 " 17 " M A X 13 1/2"MIN 30" 48 " M I N 60 " E SN T A T S ECIL T IA FO CA L I F O R N A IHCERD T C E E SN T A T S ECIL T IA FO CA LI F O R N A IHCERD T C E DL H O P E V R H A I R S A L O N 81 5 W N A O M I A V E U N I T # G AR C A D I A C A 9 1 0 0 7 60 " M A X 1" 9" REFERENCE ONLY 48 M I N EX P N L"A" EX UNISEX RESTROOM EX B R E A K R O O M D W EX I T EX I T EX I T EX I T EX SHAMPOO AREA EX CASHIER AREA EX WAITING AREA EX HAIR CUT AREA EX DRY HAIR AREA POWER PLAN DL H O P E V R H A I R S A L O N 81 5 W N A O M I A V E U N I T # G AR C A D I A C A 9 1 0 0 7 SHEET TITLE: STAMP: PROJECT ADDRESS: SHEET NUMBER 1040 S Otterbein Ave, Suite# B Rowland Heights, CA 91748 Phone: 909.569.2069 EMail: cnd9@icloud.com COMMERCIAL RESIDENTIAL INTERIOR DESIGNiDEAL GROUP, Inc. DESIGN De s i g n I n c , . 1 2 3 . E-1 ABBREVIATIONS GENERAL NOTES: 1 2 METALIC 1/2" 1/2" 3/4" 3/4" 1/2" CONDUIT WIRE LEGEND #12 THHN/THWN 3/4" 3/4" SYMBOL OF 2 3 5 6 7 4 CONDUCTORS 8 NUMBER COPPER BRKR.CONDUIT AMPS 15 20 40 60 30 200 100 1" WIRE #12 #12 #12 #12 #12 BOND #12 #12 3/4" COND- 3/4" 3/4" 3/4" UIT 3/4" 3/4" 6 WIRE # 10 10 10 14 12 8 ORC. GROUND NON-METALIC NOTE : a.LIGHT FIXTURE IN CONTACT WITH INSULATION TO BE U.L. LISTED FOR THERMAL BARRIER OR PROVIDE 3" MINIMUM CLEARANCE. b.MOUNT THE FOLLOWING ABOVE FINISH FLOOR: OUTLETS - 15" TO 48" SWITCHES - 36" TO 48" THERMOSTATS - 36" TO 48" MEASURED FROM BOTTOM AND TOP OF BOXES RESPECTIVELY c.PANEL CIRCUIT DIRECTORY TO COMPLY WITH SECT. 408.4, CEC. POWER PLAN EX EXEXEXEXEXEX EX EX EXEXEXEXEXEXEXEX EX EX EX EX EX EX EX P N L"A" EX I T EX I T EX I T EX I T CEILING PLAN DL H O P E V R H A I R S A L O N 81 5 W N A O M I A V E U N I T # G AR C A D I A C A 9 1 0 0 7 SHEET TITLE: STAMP: PROJECT ADDRESS: SHEET NUMBER 1040 S Otterbein Ave, Suite# B Rowland Heights, CA 91748 Phone: 909.569.2069 EMail: cnd9@icloud.com COMMERCIAL RESIDENTIAL INTERIOR DESIGN iDEAL GROUP, Inc. DESIGN De s i g n I n c , . 1 2 3 . E-2 NOTE NOTE: THE ILLUMINATED "EXIT" SIGN AT ALL TIMES HAVING A LIGHTINTENSITY OF NOT LESS THAN ONE FOOTCANDLE AT FLOOR LEVELWITH BATTERY BACK-UP FOR EXISTING SYSTEM WITH AN OCCUPANTLOAD OF ONE HUNDRED OR MORE. PROVIDE 365 DAYPROGRAMMABLE TIME CLOCK (PERSEC 131(d) CES 2013 EXISTING REFLECTED CEILING PLAN EXISTING LIGHTING FIXTURES REMAIN NOCHANGE NO MODIFICATIONS TITLE 24 EXIT LIGHTING FIXTURE SCHEDULE EMERGENCY LTG EMERGENCY LTG EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EX EXEXEXEXEX EX