Loading...
HomeMy WebLinkAbout733 W Naomi Ave #E - 2025 - Acai JointTENANT INPROVEMENT FOR RESTAURANT "ACAI JOINT" ASSESSORS PARCEL #: 5383-035-028 ADDRESS: 733 W Naomi Ave unit E Arcadia Ca 91007 ZONING: COMMERCIAL OCCUPANCY: B CONSTRUCTION TYPE: TYPE II, FIRE SPRINKLERS: YES---FULL FIRE SPRINKLER (NFPA-13) STORIES: 1 STORIES LEASE SPACE : 558 SQ. FT. PARCEL & PROJECT INFORMATION PROJECT DIRECTORY TENANT / APPLICANT MR. ALMON HUANG TEL: 626.400.7358 EMAIL: A1M0NHUANG@GMAIL.COM ADDRESS: 6425 Temple City Blvd, Temple City, Ca 9178 DESIGNER: Y.T.ASSOCIATES TAMMY TANG 9045 LONGDEN AVE., TEMPLE CITY CA 91780 T.626.283.7371 EAMIL:TAMMY9D266@HOTMAIL.COM ELECTRICAL ENGINEER: DANUT YATPLYAKUL 142 N. LOWELL AVE., GLENDORA, CA 91741 T.323.470.9435 E-MAIL: TEE.YATPIYAKUL@TXECORP.COM PROJECT SCOPE OF WORK TENANT IMPROVEMENT EXISTING RESTAURANT ·REMOVED EXISTING SHORT WALL AND SERVICE COUNTER ·NEW PATITION WALL AND OPENING ·NEW SERVICE COUNTER ·INSTALL NEW EQUIPMENT ·INSTALL NEW TRACK LIGHT IN CEILING ·REPAINT THE WALL AND CEILING HVAC AND PLUMBING REMAIN NO CHANGE SEPARATE PLAN CHECK & PERMIT: 1. SIGNAGE DEFERRED SUBMITTAL A. FIRE SPRINKLERS B. KITCHEN HOOD SYSTEM CODE TABULATION SHEET INDEX LEGAL DESCRIPTION VICINITY MAP SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M N PR O J E C T I N F O R M A T I O N EX I T I N G S I T E P L A N A-0.00 BUILDING DIVISION/PLANNING AND HEALTH PERMIT APPLICATION AT 733 W Naomi Ave unit E Arcadia Ca 91007 SITE PLAN1 N.T.S. N PROJECT LOCATION CODE TABULATION: 2022 CALIFORNIA BUILDING CODE, 2022 CALIFORNIA ELECTRICAL CODE, 2022 CALIFORNIA PLUMBING CODE, 2022 CALIFORNIA MECHANICAL CODE, 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2025 ARCADIA MUNICIPAL CODE PARCEL MAP AS PER BK 184 P 45-47 OF P M LOT 1 OCCUPANT LOAD ANALYSIS LOCATION OCCUPANT LOAD FACTOR FLOOR AREA OCCUPANT LOAD KITCHEN & SERVICE 200 GROSS 363 S.F. / 200 2 PERSONS RESTROOM ---- 58 S.F. ------ WAITING AREA 15 NET 137 S.F. /15 10 PERSONS TOTAL 558 S.F. 12 PERSONS A-0.00 SITE PLAN AND COVER SHEET A-1.00 EXISTING FLOOR PLAN EXISTING CEILING PLAN A-2.00 PROPOSED FLOOR PLAN PROPOSED CEILING PLAN A-2.01 KITCHEN KEY PLAN A-2.02 ELEVATION A-2.03 ELEVATION A-3.00 WALL DETAIL A-3.01 ADA DETAIL E-0.00 ELECTRICAL COVER SHEET E-0.01 ELECTRICAL NOTES E-0.02 ELECTRICAL TITLE 24 E-0.03 ELECTRICAL TITLE 24 E-2.00 ELECTRICAL POWER AND LIGHTING PLANS P-0.0 PLUMBING NOTES SCHEDLES P-0.1 NRCC-PLB-E ENERGY DOCUMENTATION P-1.0 WATER PLUMBING PLAN WASTE AND VENT PLAN P-2.0 PLUMBING DETAILS PROJECT LOCATION ACCESSIBLE ROUTES OF TRAVEL TO THE PRIMARY ENTRANCE TO THE BUILDING FROM ACCESSIBLE PARKING SPACES AND PUBLIC WAY. THE DIRECTION IN THE SLOPE OF TRAVEL NOT TO EXCEED 5% AND CROSS SLOPE OF TRAVEL NOT TO EXCEED 2.08%. INSPECTOR TO VERIFY. TRASH AREA LOCATION Valuation/Fees: The listed permit valuation of $10'000 for the TU appears to be underestimated. Provide a breakdown or justification of the cost estimate, including materials, labor, and any additional factor. Adjust the valuation and pay any remaining fees. EXISTING FLOOR PLAN SCALE: 1/4"=1'-0" 1 EXISTING PARTITION DEMOLITION PARTITION NEW PARTITION FULL HIGH TO CEILING SYMBOLS FLOOR DRAIN FLOOR SINK EXISTING PARTITION 2X STUDS 1 HOUR FIRE RATE TO REMAIN FIRE EXTINGUISHERFE NOTE: ALL EXIT SIGNS WILL BE INTERNALLY OR EXTERNALLY ILLUMINATED N LEGEND (E) DRY WALL CEILING PRAIN WHITE COLOR +8'-0" A.F.F. (E) DRY WALL CEILING PRAIN WHITE COLOR +9'-0" A.F.F. +12'-3" A.F.F. (E) DRY WALL CEILINGPRAIN WHITE COLOR +11'-9" A.F.F. (E) T-BAR CEILING EXISTING CEILING PLAN SCALE: 1/4"=1'-0" 1 N REMOVED EXISTING SHORT WALL REMOVED EXISTING SERVICE COUNTER COVER UNUSED FLOOR SINK AND FLOOR DRAIN SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M EX I S T I N G F L O O R P L A N & CE I L I N G P L A N A-1.00 PROPOSED FLOOR PLAN SCALE: 1/4"=1'-0" 2 FIXED WINDOW & NON OPERABLE (ALUMINUM FRAME WITH CLEAR TEMPERED GLASS) FINISH SCHEDULE FIXED WINDOW (ALUMINUM FRAME WITH CLEAR TEMPERED GLASS) (EXITING) TOTAL S. 1. SELF-CLOSING 2. SIGN ABOVE THE DOOR "THIS DOOR TO REMAIN UNLOCKED WHENEVER THE BUILDING IS OCCUPIED" 3. DOOR SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT DOOR AND WINDOW SCHEDULE NOTE: ALL EXIST DOORS SHALL COMPLY WITH CBC SECTION 1010.1, INCLUDING ALL OF THE FOLLOWING: A.CLEAR WIDTH OF EACH DOOR OPENING SHALL BE MIN. 32 OR PER SEC. 1005.1, WHICHEVER IS GREATER. B.MINIMUM DOOR HEIGHT OF 6'-8". C.SHALL BE CAPABLE OF OPENING 90 DEGREES. D.THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE 48" NOMINAL. E.EXIT DOORS SHALL BE SIDE-HINGED SWINGING TYPE. NOTE:THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. CBC 11 B-404.2.1 0. NOTE: THAT FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE 5 LB. MAXIMUM, PER CBC 11 B-309.4. NOTE: ALL EXIT SIGNS WILL BE INTERNALLY OR EXTERNALLY ILLUMINATED EXISTING PARTITION DEMOLITION PARTITION NEW PARTITION FULL 5' HIGH SYMBOLS FLOOR DRAIN FLOOR SINK EXISTING PARTITION 2X STUDS 1 HOUR FIRE RATE TO REMAIN FIRE EXTINGUISHER EGRESS CAPACITY MAIN ENTRY DOOR WIDTH =68" / 0.2 =340 FE N (E) DRY WALL CEILING PRAIN WHITE COLOR +8'-0" A.F.F. (E) DRY WALL CEILING PRAIN WHITE COLOR +9'-0" A.F.F. +12'-3" A.F.F. (E) DRY WALL CEILINGPRAIN WHITE COLOR +11'-9" A.F.F. (E) T-BAR CEILING EXISTING CEILING PLAN SCALE: 1/4"=1'-0" 1 N 28"-34" H. CASHIER 18X484 TIERS 18 X 4 8 4 T I E R S 18 X 4 8 4 T I E R S FE KITCHEN 198 S.F. SERVICE AREA 165 S.F. WAITING AREA 137 S.F. ALL-GENDERRESTROOM 58 S.F. (N) (N) (N) (N) (E) 1HR. FIRE REATE WALL TACTILE EXIT SIGN SEE DETAIL 4/ A-302 EXISTING ENTRY WITH 12" THRESHOLD NO CHANGES TO BE MADE D1 D2 2 A-3.00 W2 SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M PR O P O S E D F L O O R P L A N & C E I L I N G P L A N A-2.00 EQUIPMENT SCHEDULE IT E M N O ITEM QU A N T I T Y MANUFACTURE & MODEL NO. SIZE D"W"H" PLUMBING H.W.C.W. WATER WASTE DIR IDIR SIZE BTUX 1000 GAS ELECTRICAL BASE/ INSTALLATION REDMARK WALL MOUNT2EHAND SINK GSW HS-1615S 16"WX16"DX14"H 12"12"2" 115 6.51NCOLD TABLE 1 E 1-COMP. SINK 39"W X24"DX45"HADVANCE TABCO FE-1-1812-18RORL-X 12"12"FS 16" LEGS 6" LEGS 6" LEGS 4" MIN. CONT. COVED BASE 6" LEGS 115 512"FS 12"12"2" 12"12"2" 115 9.6 S/S WORK TABLE REGENCY 600TSB3036S 36"WX30"DX34"H2N 1 N 1 E 1 E 1 E 3 E 1 ICE MAKER 26"WX29"DX33"HMANITOWOC URF-0140A MOP SINK W/ BACKFLOW W/CHEM.RACK &MOP HOLDER 20"W X 28"D X 12"HADVANCE TABCO 9-OP-48 LOCKER 12"WX12"DX66"HWIN-HOLI WL-55 3-COMP. SINK ADVANCE FC-31818-18RL 90"WX24"DX34"H WIRE SHELVING BOMBO ADVANCE TABCO ECC 1848 48"WX18"DX74"H VO L T KW AM P S TRUE TSSU-60-24M-B-ST-HC N REACH IN FREEZER COMMERCIAL CASTERS TRUE T-49F-HC 54"WX29"DX79"H 61"WX34"DX40"H COMMERCIAL CASTERS MS1"1"1 E GAS. WATER HEATER 22"ØX72"HAMERICAN VG6250T76NV TOP OF MOK SINK76 TYPE OF OCCUPANCY WATER CLOSETS (FIXTURES PER PERSON) URINALS (FIX TURES PER PERSON) LAVATORIES(FIXTURES PER PERSON B MALE FEMALE MALE MALE FEMALE 1: 1-50 1: 1-25 1:1-200 1 : 1-150 1:1-150 1:1-250 1 PROPOSED OCCUPANCY LOAD 42/2 (21 PERSON) 1 1 1 1 1 WATER STATION 1 (MOP SINK) PLUMBING FIXTURE REQUIRED KITCHEN KEY PLAN SCALE: 1/4"=1'-0" 1 DRY FOOD STORAGE CALCULATION: 18"X48" RACK: (3)4X 4'=48 FT. TOTAL: 48+36=84 FT. 16'X2=32 FT. 28"-34" H. CASHIER 18X484 TIERS 18 X 4 8 4 T I E R S 18 X 4 8 4 T I E R S FE KITCHEN 198 S.F. SERVICE AREA 165 S.F. WAITING AREA 137 S.F. ALL-GENDER RESTROOM 58 S.F. 115 2.21NGLASS REF COMMERCIAL CASTERS TRUE T-19G-HC~FGDO1 27"WX25"DX75"H 120 1.81NBLENDERBLENDTEC CQB1 STEALTH 885 9"WX9"DX18"H 115 2.51NFLAT FREEZER GALAXY ICFF7-HC 34"WX22"DX33"H COMMERCIAL CASTERS 115 1.31NFLAT FREEZER MASTER-BILT MSF-31AN 32"WX28"DX33"H COMMERCIAL CASTERS 115 6.51NCOLD TABLE TRUE TSSU-60-16-HC 61"WX31"DX37"H COMMERCIAL CASTERS 2 N DOUBLE EALL SHELVING EAGLE WS1060 60"WX10"DX6"H 115 5.11EAIR CURTAIN MARS-N236-IU 36"WX13"DX11"H UTENSIL HOLDER SERVER CW 87750 16"WX11"DX6"H1N 115 3.30.4 0.5 C A BA-2.02 A-2.03 E A-2.03 D A-2.03 1 SPLASH GUARD SP-SH2410L R 28"WX11"HN SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M PR O P O S E D P A T I T I O N W A L L P L A N A N D ME A N S O F E G R E S S F L O O R P L A N A-2.01 NOTE: FACILITY ONLY FOR TO GO. "A" ELEVATION1 SCALE: 3/8"=1'-0" "B" ELEVATION2 SCALE: 3/8"=1'-0" #18(E) W.H. (N) WALL FRP FINISHED (N) WALL FRP FINISHED (N) WALL PAINT FINISH (N) WALL PAINT FINISH (N) 1/2" THK TEMP GLASS (N) GRANITE COUNTER TOP SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M EL E V A T I O N S A-2.02 PARTITION BASE ATTACHMENT7 SCALE: N.T.S. (N) GRANITE COUNTER TOP (N) WALL PAINT FINISH (N) WALL PAINT FINISH SCALE: 3/8"=1'-0" (N) 1/2" THK TEMP GLASS (N) TILE FINISH (N) WALL PAINT FINISH (N) GRANITE COUNTER TOP 1 "D" ELEVATION"B" ELEVATION 2 SCALE: 3/8"=1'-0" "E" ELEVATION3 SCALE: 3/8"=1'-0" MA X . H . (N) 1/2" THK TEMP GLASS 4 _ 5 _ 6 _ WALL SECTION 4 N.T.S. WALL SECTION 5 N.T.S. WALL SECTION 6 N.T.S. SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M EL E V A T I O N S A-2.03 PARTITION BASE ATTACHMENT3 SCALE: N.T.S. PARTITION ON FRAMING DETAILS AND SCHEDULE5 SCALE: N.T.S. BRACING ATTACHMENT1 SCALE: N.T.S. 1 38" X 3 5 8" X 20 GA. @ 16" O.C. HEIGHT BTN. SUPPORT REMARX 0'-0" TO 12'-0" (ICC ESR-3064P) INTERICR METAL STUD SIZE & SPAC'G 1 38" X 3 5 8 " X 20 GA. @ 16" O.C. 0'-0" TO 15'-0" SIZE 0'-0" TO 23'-0"1 38" X 6" X 20 GA. @ 16" O.C. 0'-0" TO 26'-0"1 38" X 6" X 18 GA. @ 16" O.C. 6' OR UNDER 12'-1" TO 16' BRACING LENGTH SCREWS 3 5 8 " X 20 GA 6'-1" TO 12'4 " X 20 GA 3-#10 EG. END 3-#10 EG. END 6 " X 20 GA 3-#10 EG. END NON-BRACING PARTITION SECTION TYP.4 SCALE: N.T.S. PARTITION TOP ATTACHENT2 SCALE: N.T.S. SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M WA T E R A N D V E N T P L A N WA T E R A N D G A S P L A N A-3.00 EXIT NOTE: MEANS OF EGRESS: ( TWO OR MORE REQUIRED EXITS) ·AT INTERIOR EXIT ACCESS DOORS LEADING TO EXIT ENCLOSURES OR EXIT PASSAGEWAYS: SIGN TO READ " EXIT ROUTE ". ·AT INTERIOR EXIT DOORS LEADING TO A MALL COMMONS: SIGN TO READ "EXIT" B. ACCESSIBLE PARKING @ SIDEWALK ACCESSIBLE PARKING1 EXIT IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY A CONTINUOUS DETECTABLE WARNING WHICH IS 36" WIDE. 60" SCALE: N.T.S5 THRESHOLD/ LEVEL CHANGES2 INSTALL OPERATING HARDWARE 34 - TO 44 INCHES ABOVE FLOOR 5 LB. MAX. EFFORT TO OPERATE INTERIOR AND EXTERIOR DOORS. ACCESSIBLE DOOR OPERATING HARDWARE6 NOTE: SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE. AREA OF SIGN TO BE A MIN. OF 70 SQ. IN. DESIGNATE FOR "VAN ACCESSIBLE" WHERE APPROPRIATE. EMBLEM MUST BE LOCATED IN STALL SO THAT IS VISIBLE BY A TRAFFIC ENFORCEMENT OFFICER WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE (CENTERED AT ENTRANCE TO STALL RECOMMENDED) A. ACCESSIBLE PARKING STALL INTERNATIONAL SYMBOL OF ACCESSIBILITY SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S 4 TACTILE SIGNS TRUNCATED DOMES N.T.S3SCALE: N.T.S SCALE: N.T.S SIDE REACH RANGES DETAIL8SCALE: N.T.S A. UNOBSTRUCTED FORWARD REACH B. OBSTRUCTED FORWARD REACH C. OBSTRUCTED FORWARD REACH A. UNOBSTRUCTED SIDE REACH B. OBSTRUCTED SIDE REACH C. OBSTRUCTED SIDE REACH ROUTE EXIT CL CL LOCATION OF TACTILE SIGNS AT DOORS N.T.S9ENTRANCES & EXITS, DOORS NOTES: 1. 12" MAXIMUM TOTAL HEIGHT WITH 14" MAXIMUM VERTICAL CHANGE AT EDGE. 2.1:2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER 14" VERTICAL LEVEL CHANGE. 3.14" MAXIMUM VERTICAL LEVEL CHANGE. A: LEVEL CHANGES B: THRESHOLD C: TRANSITION BETWEEN FLOOR FINISHES D. LIMITS OF PROTRUDING OBJECTS SOAP DISPENSER. TOILET PAPER HOLDER. (TILE, CEMENT, MARLITE ETC). PAPER TOWEL DISPENSER. TOILET SEAT COVER DISPENSER. SMOOTH, HARD, NONABSORBENT SURFACE MIRROR GRAB BAR: UNDER LAVATORY. 1. NO SHARP OR ABRASIVE SURFACES 2. LEVER FAUCET CONTROLS OPERABLE. 3. HOT WATER SUPPLY AND DRAIN PIPING INSULATED. 1. FLUSH CONTROL HANDLE ON WIDE SIDE WITH 3 LBS. MAXIMUM OPERATING FORCE. WATER CLOSET: LAVATORY: WITH ONE HAND AND 5 LBS. MAXIMUM FORCE. LAVATORIES SHALL BE INSULATED OR OTHERWISE. HOT WATER AND DRAINPIPES UNDER ACCESSIBLE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 1.THE OUTER DIAMETER OF A CIRCULAR GRAB BAR TO BE 1-1/4" MINIMUM AND 2" MAXIMUM. NONCIRCULAR GRAB BARS SHALL COMPLY WITH CBC 11-B-609.2.2 2.PROVIDE SOLID BACKING FOR MOUNTING OF BARS. 3.NO ROTATION PERMITTED IF FITTINGS USED. ACCESSIBLE RESTROOM DETAILS11 C G H J SCALE: N.T.S A E D F J DRAWN BY JIMMY Z H A N G ( 6 2 6 ) 5 7 0 - 9 9 7 8 DESIGN FOR RE S T A U R A N T P L U S , I N C . 7 RESTROOM SIGNAGE SCALE: N.T.S NOTE: DOOR SIGN SHALL BE IDENTIFIED BY A 1 4" THICK, 12" IN DIAMETER-CIRCLE, WITH A 1 4" THICK TRANGLE SUPERIMPOSEDE ON THE CIRCLE AND WITHIN THE 12" WITH NO PICTOGRAM. TRACTILE AN DBRAILLE SIGNAGE ON WALL SHALL IDENTIFY THE RESTROOM AS "RESTROOM", "ALL-GENDER RESTROOM", OR UNISEX RESTROOM". UNISEX OR ALL GENDER NOTE: 1.DOOR SIGN SHALL BE MOUNTED ON THE CENTERLINE OF THE DOOR AND BETWEEN 58" AND 60" FROM THE FINISHED FLOOR. 2.DOOR SHALL HAVE PRIVACY LATCHES 10 SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M AD A D E T A I L S A-3.01 REFER TO ARCHITECTURAL, STRUCTURAL, CIVIL, LANDSCAPE DRAWINGS FOR DISCIPLINE SPECIFIC WORK AND TO COORDINATE ALL IMPROVEMENT WORKS. NOTES TO CONTRACTOR: SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M PL U M B I N G N O T E S S C H E D L E S P-0 SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M NR C C - P L B - E E N E R G Y DO C U M E N T A T I O N P-0.1 EXISTING PARTITION DEMOLITION PARTITION NEW PARTITION FULL HIGH TO CEILING SYMBOLS FLOOR DRAIN FLOOR SINK EXISTING PARTITION 2X STUDS 1 HOUR FIRE RATE TO REMAIN NEW PARTITION 48" H. 1 SCALE: 1/4"=1'0" WASTE AND VENT PLAN WATER SIZING CALCULATIONS NOTE: ALL THE PLUMBING S ARE EXISTING. ADJUST $ REINSTALL FIXTURES AS NEEDED 28"-34" H. CASHIER 18X484 TIERS 18 X 4 8 4 T I E R S 18 X 4 8 4 T I E R S FE ~~ 28"-34" H. CASHIER 18X484 TIERS 18 X 4 8 4 T I E R S 18 X 4 8 4 T I E R S FE 2 SCALE: 1/4"=1'0" WATER AND GAS PLAN ~ SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M WA T E R P L U M B I N G P L A N & WA S T E A N D V E N T P L A N P-1 WALL CLEANOUT 1 N.T.S. FLOOR SINK DETAIL 2 N.T.S. .. CONDENSATE DRAIN 3 N.T.S. TRAP PRIMER DETAIL 4 N.T.S. 3 COMPARTMENT SINK DETAIL 6 N.T.S. VEGETABLE SINK 6 N.T.S. TYPICAL FLOOR SINK 7 N.T.S. CONSTRUCTION NOTES: 8 N.T.S. WATER HEATDETAIL9 N.T.S. ISLAND VENT DETAIL9 N.T.S. SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M PL U M B I N G D E T A I L S P-2 TENANT INPROVEMENT FOR RESTAURANT "ACAI JOINT" ASSESSORS PARCEL #: 5383-035-028 ADDRESS: 733 W Naomi Ave unit E Arcadia Ca 91007 ZONING: COMMERCIAL OCCUPANCY: B CONSTRUCTION TYPE: TYPE II, FIRE SPRINKLERS: YES---FULL FIRE SPRINKLER (NFPA-13) STORIES: 1 STORIES LEASE SPACE : 558 SQ. FT. PARCEL & PROJECT INFORMATION PROJECT DIRECTORY TENANT / APPLICANT MR. ALMON HUANG TEL: 626.400.7358 EMAIL: A1M0NHUANG@GMAIL.COM ADDRESS: 6425 Temple City Blvd, Temple City, Ca 9178 DESIGNER: Y.T.ASSOCIATES TAMMY TANG 9045 LONGDEN AVE., TEMPLE CITY CA 91780 T.626.283.7371 EAMIL:TAMMY9D266@HOTMAIL.COM ELECTRICAL ENGINEER: DANUT YATPLYAKUL 142 N. LOWELL AVE., GLENDORA, CA 91741 T.323.470.9435 E-MAIL: TEE.YATPIYAKUL@TXECORP.COM PROJECT SCOPE OF WORK TENANT IMPROVEMENT EXISTING RESTAURANT ·REMOVED EXISTING SHORT WALL AND SERVICE COUNTER ·NEW PATITION WALL AND OPENING ·NEW SERVICE COUNTER ·INSTALL NEW EQUIPMENT ·INSTALL NEW TRACK LIGHT IN CEILING ·REPAINT THE WALL AND CEILING HVAC AND PLUMBING REMAIN NO CHANGE SEPARATE PLAN CHECK & PERMIT: 1. SIGNAGE DEFERRED SUBMITTAL A. FIRE SPRINKLERS B. KITCHEN HOOD SYSTEM CODE TABULATION SHEET INDEX LEGAL DESCRIPTION VICINITY MAP SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M N PR O J E C T I N F O R M A T I O N EX I T I N G S I T E P L A N A-0.00 BUILDING DIVISION/PLANNING AND HEALTH PERMIT APPLICATION AT 733 W Naomi Ave unit E Arcadia Ca 91007 SITE PLAN1 N.T.S. N PROJECT LOCATION CODE TABULATION: 2022 CALIFORNIA BUILDING CODE, 2022 CALIFORNIA ELECTRICAL CODE, 2022 CALIFORNIA PLUMBING CODE, 2022 CALIFORNIA MECHANICAL CODE, 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2025 ARCADIA MUNICIPAL CODE PARCEL MAP AS PER BK 184 P 45-47 OF P M LOT 1 OCCUPANT LOAD ANALYSIS LOCATION OCCUPANT LOAD FACTOR FLOOR AREA OCCUPANT LOAD KITCHEN & SERVICE 200 GROSS 363 S.F. / 200 2 PERSONS RESTROOM ---- 58 S.F. ------ WAITING AREA 15 NET 137 S.F. /15 10 PERSONS TOTAL 558 S.F. 12 PERSONS A-0.00 SITE PLAN AND COVER SHEET A-1.00 EXISTING FLOOR PLAN EXISTING CEILING PLAN A-2.00 PROPOSED FLOOR PLAN PROPOSED CEILING PLAN A-2.01 KITCHEN KEY PLAN A-2.02 ELEVATION A-2.03 ELEVATION A-3.00 WALL DETAIL A-3.01 ADA DETAIL E-0.00 ELECTRICAL COVER SHEET E-0.01 ELECTRICAL NOTES E-0.02 ELECTRICAL TITLE 24 E-0.03 ELECTRICAL TITLE 24 E-2.00 ELECTRICAL POWER AND LIGHTING PLANS P-0.0 PLUMBING NOTES SCHEDLES P-0.1 NRCC-PLB-E ENERGY DOCUMENTATION P-1.0 WATER PLUMBING PLAN WASTE AND VENT PLAN P-2.0 PLUMBING DETAILS PROJECT LOCATION ACCESSIBLE ROUTES OF TRAVEL TO THE PRIMARY ENTRANCE TO THE BUILDING FROM ACCESSIBLE PARKING SPACES AND PUBLIC WAY. THE DIRECTION IN THE SLOPE OF TRAVEL NOT TO EXCEED 5% AND CROSS SLOPE OF TRAVEL NOT TO EXCEED 2.08%. INSPECTOR TO VERIFY. TRASH AREA LOCATION EXISTING FLOOR PLAN SCALE: 1/4"=1'-0" 1 EXISTING PARTITION DEMOLITION PARTITION NEW PARTITION FULL HIGH TO CEILING SYMBOLS FLOOR DRAIN FLOOR SINK EXISTING PARTITION 2X STUDS 1 HOUR FIRE RATE TO REMAIN FIRE EXTINGUISHERFE NOTE: ALL EXIT SIGNS WILL BE INTERNALLY OR EXTERNALLY ILLUMINATED N LEGEND (E) DRY WALL CEILING PRAIN WHITE COLOR +8'-0" A.F.F. (E) DRY WALL CEILING PRAIN WHITE COLOR +9'-0" A.F.F. +12'-3" A.F.F. (E) DRY WALL CEILINGPRAIN WHITE COLOR +11'-9" A.F.F. (E) T-BAR CEILING EXISTING CEILING PLAN SCALE: 1/4"=1'-0" 1 N REMOVED EXISTING SHORT WALL REMOVED EXISTING SERVICE COUNTER COVER UNUSED FLOOR SINK AND FLOOR DRAIN SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M EX I S T I N G F L O O R P L A N & CE I L I N G P L A N A-1.00 PROPOSED FLOOR PLAN SCALE: 1/4"=1'-0" 2 FIXED WINDOW & NON OPERABLE (ALUMINUM FRAME WITH CLEAR TEMPERED GLASS) FINISH SCHEDULE FIXED WINDOW (ALUMINUM FRAME WITH CLEAR TEMPERED GLASS) (EXITING) TOTAL S. 1. SELF-CLOSING 2. SIGN ABOVE THE DOOR "THIS DOOR TO REMAIN UNLOCKED WHENEVER THE BUILDING IS OCCUPIED" 3. DOOR SHALL BE OPENABLE FROM INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT DOOR AND WINDOW SCHEDULE NOTE: ALL EXIST DOORS SHALL COMPLY WITH CBC SECTION 1010.1, INCLUDING ALL OF THE FOLLOWING: A.CLEAR WIDTH OF EACH DOOR OPENING SHALL BE MIN. 32 OR PER SEC. 1005.1, WHICHEVER IS GREATER. B.MINIMUM DOOR HEIGHT OF 6'-8". C.SHALL BE CAPABLE OF OPENING 90 DEGREES. D.THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL BE 48" NOMINAL. E.EXIT DOORS SHALL BE SIDE-HINGED SWINGING TYPE. NOTE:THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. CBC 11 B-404.2.1 0. NOTE: THAT FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE 5 LB. MAXIMUM, PER CBC 11 B-309.4. NOTE: ALL EXIT SIGNS WILL BE INTERNALLY OR EXTERNALLY ILLUMINATED EXISTING PARTITION DEMOLITION PARTITION NEW PARTITION FULL 5' HIGH SYMBOLS FLOOR DRAIN FLOOR SINK EXISTING PARTITION 2X STUDS 1 HOUR FIRE RATE TO REMAIN FIRE EXTINGUISHER EGRESS CAPACITY MAIN ENTRY DOOR WIDTH =68" / 0.2 =340 FE N (E) DRY WALL CEILING PRAIN WHITE COLOR +8'-0" A.F.F. (E) DRY WALL CEILING PRAIN WHITE COLOR +9'-0" A.F.F. +12'-3" A.F.F. (E) DRY WALL CEILINGPRAIN WHITE COLOR +11'-9" A.F.F. (E) T-BAR CEILING EXISTING CEILING PLAN SCALE: 1/4"=1'-0" 1 N 28"-34" H. CASHIER 18X484 TIERS 18 X 4 8 4 T I E R S 18 X 4 8 4 T I E R S FE KITCHEN 198 S.F. SERVICE AREA 165 S.F. WAITING AREA 137 S.F. ALL-GENDERRESTROOM 58 S.F. (N) (N) (N) (N) (E) 1HR. FIRE REATE WALL TACTILE EXIT SIGN SEE DETAIL 4/ A-302 EXISTING ENTRY WITH 12" THRESHOLD NO CHANGES TO BE MADE D1 D2 2 A-3.00 W2 SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M PR O P O S E D F L O O R P L A N & C E I L I N G P L A N A-2.00 EQUIPMENT SCHEDULE IT E M N O ITEM QU A N T I T Y MANUFACTURE & MODEL NO. SIZE D"W"H" PLUMBING H.W.C.W. WATER WASTE DIR IDIR SIZE BTUX 1000 GAS ELECTRICAL BASE/ INSTALLATION REDMARK WALL MOUNT2EHAND SINK GSW HS-1615S 16"WX16"DX14"H 12"12"2" 115 6.51NCOLD TABLE 1 E 1-COMP. SINK 39"W X24"DX45"HADVANCE TABCO FE-1-1812-18RORL-X 12"12"FS 16" LEGS 6" LEGS 6" LEGS 4" MIN. CONT. COVED BASE 6" LEGS 115 512"FS 12"12"2" 12"12"2" 115 9.6 S/S WORK TABLE REGENCY 600TSB3036S 36"WX30"DX34"H2N 1 N 1 E 1 E 1 E 3 E 1 ICE MAKER 26"WX29"DX33"HMANITOWOC URF-0140A MOP SINK W/ BACKFLOW W/CHEM.RACK &MOP HOLDER 20"W X 28"D X 12"HADVANCE TABCO 9-OP-48 LOCKER 12"WX12"DX66"HWIN-HOLI WL-55 3-COMP. SINK ADVANCE FC-31818-18RL 90"WX24"DX34"H WIRE SHELVING BOMBO ADVANCE TABCO ECC 1848 48"WX18"DX74"H VO L T KW AM P S TRUE TSSU-60-24M-B-ST-HC N REACH IN FREEZER COMMERCIAL CASTERS TRUE T-49F-HC 54"WX29"DX79"H 61"WX34"DX40"H COMMERCIAL CASTERS MS1"1"1 E GAS. WATER HEATER 22"ØX72"HAMERICAN VG6250T76NV TOP OF MOK SINK76 TYPE OF OCCUPANCY WATER CLOSETS (FIXTURES PER PERSON) URINALS (FIX TURES PER PERSON) LAVATORIES(FIXTURES PER PERSON B MALE FEMALE MALE MALE FEMALE 1: 1-50 1: 1-25 1:1-200 1 : 1-150 1:1-150 1:1-250 1 PROPOSED OCCUPANCY LOAD 42/2 (21 PERSON) 1 1 1 1 1 WATER STATION 1 (MOP SINK) PLUMBING FIXTURE REQUIRED KITCHEN KEY PLAN SCALE: 1/4"=1'-0" 1 DRY FOOD STORAGE CALCULATION: 18"X48" RACK: (3)4X 4'=48 FT. TOTAL: 48+36=84 FT. 16'X2=32 FT. 28"-34" H. CASHIER 18X484 TIERS 18 X 4 8 4 T I E R S 18 X 4 8 4 T I E R S FE KITCHEN 198 S.F. SERVICE AREA 165 S.F. WAITING AREA 137 S.F. ALL-GENDER RESTROOM 58 S.F. 115 2.21NGLASS REF COMMERCIAL CASTERS TRUE T-19G-HC~FGDO1 27"WX25"DX75"H 120 1.81NBLENDERBLENDTEC CQB1 STEALTH 885 9"WX9"DX18"H 115 2.51NFLAT FREEZER GALAXY ICFF7-HC 34"WX22"DX33"H COMMERCIAL CASTERS 115 1.31NFLAT FREEZER MASTER-BILT MSF-31AN 32"WX28"DX33"H COMMERCIAL CASTERS 115 6.51NCOLD TABLE TRUE TSSU-60-16-HC 61"WX31"DX37"H COMMERCIAL CASTERS 2 N DOUBLE EALL SHELVING EAGLE WS1060 60"WX10"DX6"H 115 5.11EAIR CURTAIN MARS-N236-IU 36"WX13"DX11"H UTENSIL HOLDER SERVER CW 87750 16"WX11"DX6"H1N 115 3.30.4 0.5 C A BA-2.02 A-2.03 E A-2.03 D A-2.03 1 SPLASH GUARD SP-SH2410L R 28"WX11"HN SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M PR O P O S E D P A T I T I O N W A L L P L A N A N D ME A N S O F E G R E S S F L O O R P L A N A-2.01 NOTE: FACILITY ONLY FOR TO GO. FINAL INSPECTION AND APPROVAL ARE REQUIRED PRIOR TO THE START OF OPERATION. THE DEPARTMENT REQUIRES AT LEAST THREE WORKING DAYS NOTICE PRIOR TO THE DATE OF THE FINAL INSPECTION. BEFORE STARTING CONSTRUCTION, A BUILDING PERMIT MUST BE OBTAINED FROM YOUR BUILDING AND SAFETY DEPARTMENT ANY CHANGES TO APPROVED PLAN MUST BE BROUGHT TO YOUR PLAN CHECKERS ATTENTION WARNING!! IT IS MISDEMEANOR VIOLATION TO BEGIN OPERATION WITHOUT A FINAL INSPECTION AND A VALID HEALTH PERMIT/LICENSE. YOUR HEALTH PERMIT/LICENSE WILL BE ISSUED BY LA COUNTY HEALTH OFFICER AT THE JOB SITE. REMODELED AREAS OF EXISTING FOOD ESTABLISHMENT/FACILITY MUST ALSO HAVE A FINAL INSPECTION. COUNTY OF LOS ANGELES - DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALTH - PLAN CHECK PROGRAM THE PROPOSED CONSTRUCTION/EQUIPMENT INSTALLATION IS APPROVED: RESTAURANT - SR0402553 TYPE OF ESTABLISHMENT/SERVICE REQUEST# THE APPROVAL DOES NOT AUTHORIZE THE VIOLATION OF ANY LAW, ORDINANCE OR REGULATION. APPROVED: 04/15/2025 BY: VICKI NGO DATE PLAN CHECK INSPECTOR (SEE PLAN APPROVAL SHEET, ATTACHED) LOS ANGELES COUNTY DEPARTMENT OF PUBLIC HEALTH PLAN CHECK PROGRAM 5050 COMMERCE DR BALDWIN PARK, CA 91706 (626) 430-5560 "A" ELEVATION1 SCALE: 3/8"=1'-0" "B" ELEVATION2 SCALE: 3/8"=1'-0" #18(E) W.H. (N) WALL FRP FINISHED (N) WALL FRP FINISHED (N) WALL PAINT FINISH (N) WALL PAINT FINISH (N) 1/2" THK TEMP GLASS (N) GRANITE COUNTER TOP SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M EL E V A T I O N S A-2.02 PARTITION BASE ATTACHMENT7 SCALE: N.T.S. (N) GRANITE COUNTER TOP (N) WALL PAINT FINISH (N) WALL PAINT FINISH SCALE: 3/8"=1'-0" (N) 1/2" THK TEMP GLASS (N) TILE FINISH (N) WALL PAINT FINISH (N) GRANITE COUNTER TOP 1 "D" ELEVATION"B" ELEVATION 2 SCALE: 3/8"=1'-0" "E" ELEVATION3 SCALE: 3/8"=1'-0" MA X . H . (N) 1/2" THK TEMP GLASS 4 _ 5 _ 6 _ WALL SECTION 4 N.T.S. WALL SECTION 5 N.T.S. WALL SECTION 6 N.T.S. SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M EL E V A T I O N S A-2.03 PARTITION BASE ATTACHMENT3 SCALE: N.T.S. PARTITION ON FRAMING DETAILS AND SCHEDULE5 SCALE: N.T.S. BRACING ATTACHMENT1 SCALE: N.T.S. 1 38" X 3 5 8" X 20 GA. @ 16" O.C. HEIGHT BTN. SUPPORT REMARX 0'-0" TO 12'-0" (ICC ESR-3064P) INTERICR METAL STUD SIZE & SPAC'G 1 38" X 3 5 8 " X 20 GA. @ 16" O.C. 0'-0" TO 15'-0" SIZE 0'-0" TO 23'-0"1 38" X 6" X 20 GA. @ 16" O.C. 0'-0" TO 26'-0"1 38" X 6" X 18 GA. @ 16" O.C. 6' OR UNDER 12'-1" TO 16' BRACING LENGTH SCREWS 3 5 8 " X 20 GA 6'-1" TO 12'4 " X 20 GA 3-#10 EG. END 3-#10 EG. END 6 " X 20 GA 3-#10 EG. END NON-BRACING PARTITION SECTION TYP.4 SCALE: N.T.S. PARTITION TOP ATTACHENT2 SCALE: N.T.S. SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M WA T E R A N D V E N T P L A N WA T E R A N D G A S P L A N A-3.00 EXIT NOTE: MEANS OF EGRESS: ( TWO OR MORE REQUIRED EXITS) ·AT INTERIOR EXIT ACCESS DOORS LEADING TO EXIT ENCLOSURES OR EXIT PASSAGEWAYS: SIGN TO READ " EXIT ROUTE ". ·AT INTERIOR EXIT DOORS LEADING TO A MALL COMMONS: SIGN TO READ "EXIT" B. ACCESSIBLE PARKING @ SIDEWALK ACCESSIBLE PARKING1 EXIT IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY A CONTINUOUS DETECTABLE WARNING WHICH IS 36" WIDE. 60" SCALE: N.T.S5 THRESHOLD/ LEVEL CHANGES2 INSTALL OPERATING HARDWARE 34 - TO 44 INCHES ABOVE FLOOR 5 LB. MAX. EFFORT TO OPERATE INTERIOR AND EXTERIOR DOORS. ACCESSIBLE DOOR OPERATING HARDWARE6 NOTE: SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE. AREA OF SIGN TO BE A MIN. OF 70 SQ. IN. DESIGNATE FOR "VAN ACCESSIBLE" WHERE APPROPRIATE. EMBLEM MUST BE LOCATED IN STALL SO THAT IS VISIBLE BY A TRAFFIC ENFORCEMENT OFFICER WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE (CENTERED AT ENTRANCE TO STALL RECOMMENDED) A. ACCESSIBLE PARKING STALL INTERNATIONAL SYMBOL OF ACCESSIBILITY SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S 4 TACTILE SIGNS TRUNCATED DOMES N.T.S3SCALE: N.T.S SCALE: N.T.S SIDE REACH RANGES DETAIL8SCALE: N.T.S A. UNOBSTRUCTED FORWARD REACH B. OBSTRUCTED FORWARD REACH C. OBSTRUCTED FORWARD REACH A. UNOBSTRUCTED SIDE REACH B. OBSTRUCTED SIDE REACH C. OBSTRUCTED SIDE REACH ROUTE EXIT CL CL LOCATION OF TACTILE SIGNS AT DOORS N.T.S9ENTRANCES & EXITS, DOORS NOTES: 1. 12" MAXIMUM TOTAL HEIGHT WITH 14" MAXIMUM VERTICAL CHANGE AT EDGE. 2.1:2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER 14" VERTICAL LEVEL CHANGE. 3.14" MAXIMUM VERTICAL LEVEL CHANGE. A: LEVEL CHANGES B: THRESHOLD C: TRANSITION BETWEEN FLOOR FINISHES D. LIMITS OF PROTRUDING OBJECTS SOAP DISPENSER. TOILET PAPER HOLDER. (TILE, CEMENT, MARLITE ETC). PAPER TOWEL DISPENSER. TOILET SEAT COVER DISPENSER. SMOOTH, HARD, NONABSORBENT SURFACE MIRROR GRAB BAR: UNDER LAVATORY. 1. NO SHARP OR ABRASIVE SURFACES 2. LEVER FAUCET CONTROLS OPERABLE. 3. HOT WATER SUPPLY AND DRAIN PIPING INSULATED. 1. FLUSH CONTROL HANDLE ON WIDE SIDE WITH 3 LBS. MAXIMUM OPERATING FORCE. WATER CLOSET: LAVATORY: WITH ONE HAND AND 5 LBS. MAXIMUM FORCE. LAVATORIES SHALL BE INSULATED OR OTHERWISE. HOT WATER AND DRAINPIPES UNDER ACCESSIBLE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. 1.THE OUTER DIAMETER OF A CIRCULAR GRAB BAR TO BE 1-1/4" MINIMUM AND 2" MAXIMUM. NONCIRCULAR GRAB BARS SHALL COMPLY WITH CBC 11-B-609.2.2 2.PROVIDE SOLID BACKING FOR MOUNTING OF BARS. 3.NO ROTATION PERMITTED IF FITTINGS USED. ACCESSIBLE RESTROOM DETAILS11 C G H J SCALE: N.T.S A E D F J DRAWN BY JIMMY Z H A N G ( 6 2 6 ) 5 7 0 - 9 9 7 8 DESIGN FOR RE S T A U R A N T P L U S , I N C . 7 RESTROOM SIGNAGE SCALE: N.T.S NOTE: DOOR SIGN SHALL BE IDENTIFIED BY A 1 4" THICK, 12" IN DIAMETER-CIRCLE, WITH A 1 4" THICK TRANGLE SUPERIMPOSEDE ON THE CIRCLE AND WITHIN THE 12" WITH NO PICTOGRAM. TRACTILE AN DBRAILLE SIGNAGE ON WALL SHALL IDENTIFY THE RESTROOM AS "RESTROOM", "ALL-GENDER RESTROOM", OR UNISEX RESTROOM". UNISEX OR ALL GENDER NOTE: 1.DOOR SIGN SHALL BE MOUNTED ON THE CENTERLINE OF THE DOOR AND BETWEEN 58" AND 60" FROM THE FINISHED FLOOR. 2.DOOR SHALL HAVE PRIVACY LATCHES 10 SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M AD A D E T A I L S A-3.01 REFER TO ARCHITECTURAL, STRUCTURAL, CIVIL, LANDSCAPE DRAWINGS FOR DISCIPLINE SPECIFIC WORK AND TO COORDINATE ALL IMPROVEMENT WORKS. NOTES TO CONTRACTOR: SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M PL U M B I N G N O T E S S C H E D L E S P-0 SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M NR C C - P L B - E E N E R G Y DO C U M E N T A T I O N P-0.1 EXISTING PARTITION DEMOLITION PARTITION NEW PARTITION FULL HIGH TO CEILING SYMBOLS FLOOR DRAIN FLOOR SINK EXISTING PARTITION 2X STUDS 1 HOUR FIRE RATE TO REMAIN NEW PARTITION 48" H. 1 SCALE: 1/4"=1'0" WASTE AND VENT PLAN WATER SIZING CALCULATIONS NOTE: ALL THE PLUMBING S ARE EXISTING. ADJUST $ REINSTALL FIXTURES AS NEEDED 28"-34" H. CASHIER 18X484 TIERS 18 X 4 8 4 T I E R S 18 X 4 8 4 T I E R S FE ~~ 28"-34" H. CASHIER 18X484 TIERS 18 X 4 8 4 T I E R S 18 X 4 8 4 T I E R S FE 2 SCALE: 1/4"=1'0" WATER AND GAS PLAN ~ SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M WA T E R P L U M B I N G P L A N & WA S T E A N D V E N T P L A N P-1 WALL CLEANOUT 1 N.T.S. FLOOR SINK DETAIL 2 N.T.S. .. CONDENSATE DRAIN 3 N.T.S. TRAP PRIMER DETAIL 4 N.T.S. 3 COMPARTMENT SINK DETAIL 6 N.T.S. VEGETABLE SINK 6 N.T.S. TYPICAL FLOOR SINK 7 N.T.S. CONSTRUCTION NOTES: 8 N.T.S. WATER HEATDETAIL9 N.T.S. ISLAND VENT DETAIL9 N.T.S. SH E E T T I T L E : PR O J E C T : 73 3 W N A O M I A V E U N I T E AR C A D I A C A 9 1 0 0 7 TE N A N T I M P R O V E M E N T R E S T A U R A N T ( A C A I J O I N T ) Y. T . AS S O C A I T E S TA M M Y T A N G 90 4 5 L O N G D E N A V E . , T E M P L E C I T Y , C A 9 1 7 8 0 T. 6 2 6 . 2 8 3 . 7 3 7 1 E- M A I L : Y T A S S O C I A T E S 9 D 2 6 6 @ G M A I L . C O M PL U M B I N G D E T A I L S P-2