Loading...
HomeMy WebLinkAbout2401 El Monte Ave - 2025 - Tmobile Cell SiteNO SCALE IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3T-1 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION SITE INFORMATION PROJECT TEAM DRAWING INDEX LOCATION MAPPROJECT DESCRIPTION APPLICABLE CODES & REFERENCE DOCUMENTS CARRIER/APPLICANT: SOUTHERN CALIFORNIA EDISON (800) 950-2356 ELECTRIC PROVIDER: AT&T (800) 331-0500 TELCO PROVIDER: U IIB FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: A.D.A. COMPLIANCE: AREA OF CONSTRUCTION: CURRENT ZONING: MAP/PARCEL #: EXISTING RESIDENTIAL 5787-018-900 PROPERTY OWNER: CROWN CASTLE 2000 CORPORATE DRIVE CANONSBURG, PA 15317 TOWER OWNER: CITY OF ARCADIA 11800 GOLDRING RD ARCADIA, CA 91066 LATITUDE: LONGITUDE: LAT/LONG TYPE: GROUND ELEVATION: JURISDICTION:CITY OF ARCADIA, CA 240 W. HUNTINGTON DRIVE, PO BOX 60021 ARCADIA, CA 91066-6021 CROWN CASTLE USA INC. SITE NAME: BU NUMBER: IE397 MIHAI PINE 824709 2401 EL MONTE AVENUESITE ADDRESS: COUNTY: 34° 06' 40.00" / 34.111111° N -118° 02' 18.72" / 118.038533° W NAD83 372' ± SE STRUCTURAL ANALYSIS: DATED: CROWN CASTLE 12/26/2024 REFERENCE DOCUMENTS: MOUNT ANALYSIS: DATED: B+T GROUP 12/22/2024 RFDS REVISION: DATED: 6 11/13/2024 ORDER ID: REVISION: 689059 0 PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER. ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. T-MOBILE SITE NUMBER: T-MOBILE SITE NAME: T-MOBILE PROJECT: RAN TEMPLATE: BUSINESS UNIT #: SITE ADDRESS: COUNTY: SITE TYPE: TOWER HEIGHT: 824709IE05397B TMT IE397 MIHAI PINE IE05397B 2401 EL MONTE AVENUE ARCADIA, CA 91007 LOS ANGELES MONOPOLE 50'-0" ARCADIA, CA 91007 LOS ANGELES TMT IE397 MIHAI PINE L600 CALL CALIFORNIA ONE CALL (800) 227-2600 CALL 3 WORKING DAYS BEFORE YOU DIG! THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. T-MOBILE 1200 CONCORD AVENUE SUITE 500 CONCORD, CA 94520 TITLE SHEETT-1 GENERAL NOTEST-2 C-1.1 EXISTING EQUIPMENT PLAN C-1.2 TOWER ELEVATIONSC-2.1 SITE SUPPORT CABINET SPECIFICATIONS BATTERY CABINET SPECIFICATIONS E-1 ENCLOSURE CLEARANCES FINAL EQUIPMENT PLAN PANEL SCHEDULES & ONE-LINE DIAGRAM FINAL EQUIPMENT SCHEDULE SHEET #SHEET DESCRIPTION ANTENNA PLANSC-3 C-4 C-5.1 GROUND EQUIPMENT DETAILS & SPECIFICATIONS C-6.1 C-6.2 C-6.3 E-2 ELECTRICAL DETAILS G-1 TYPICAL GROUNDING SCHEMATIC G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS 67E5A998E 6160 A&E FIRM: CROWN CASTLE 2000 CORPORATE DRIVE CANONSBURG, PA 15317 C-5.2 TOWER EQUIPMENT DETAILS & SPECIFICATIONS TOWER SCOPE OF WORK: •REMOVE (3) HYBRID CABLES •INSTALL (3) ERICSSON - 4480 RRUS GROUND SCOPE OF WORK: •REMOVE (1) EXISTING RBS - 6131 CABINET •INSTALL (1) 6160 CABINET •INSTALL (1) B160 CABINET ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2022 CALIFORNIA BUILDING CODE (CBC)/2021 IBC MECHANICAL 2022 CALIFORNIA MECHANICAL CODE (CMC)/2021 UMC ELECTRICAL 2022 CALIFORNIA ELECTRICAL CODE (CEC)/2020 NEC KIMLEY-HORN & ASSOCIATES, INC. 3875 EMBASSY PKWY, SUITE 280 AKRON, OH 44333 MICHAEL.KRIEG@KIMLEY-HORN.COM TOWER ELEVATIONSC-2.2 NOTE: •ANTENNAS SHALL BE PAINTED TO MATCH THE EXISTING COLOR OF THE ENCLOSURE OR EXISTING MONOPINE TO PROVIDE ADDITIONAL STEALTH. •THE WIRELESS FACILITY INCLUDING THE ENCLOSURE SHALL BE MAINTAINED IN APPEARANCE, REPLACEMENT OF WORN, FADED, DETERIORATED PORTIONS OF THE WIRELESS FACILITY SHALL BE REPLACED OR REPAIRED SO THAT THE FACILITY APPEARS AS THE PROJECT WAS APPROVED. 04/23/25Exp. 03/31/27 Digitally signed by Eric Embick DN: cn=Eric Embick, c=US, email=Eric.Embick@kimley- horn.com Date: 2025.04.23 14:00:32 -04'00' Eric Embick IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3T-2 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-1.1 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-1.2 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-2.1 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-2.2 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-3 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-4 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-5.1 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION RRU SPECIFICATIONS RRU MODEL A B C WEIGHT (LBS) 4480-TMOV2 22.0"15.7"7.5"81.0 ERICSSON FRONT VIEWSIDE VIEW A C B TOP VIEW 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-5.2 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-6.1 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION PLAN VIEWSIDE VIEW PLAN VIEWSIDE VIEW 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-6.2 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION · · ” LEFT VIEW FRONT VIEW RIGHT VIEW REAR VIEW DOOR SWING PLAN VIEW BOLT DOWN PATTERN 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3C-6.3 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION ” FRONT VIEWLEFT VIEW RIGHT VIEW DOOR SWING PLAN VIEWREAR VIEW 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3E-1 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3E-2 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3G-1 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3G-2 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3G-3 REVISION:SHEET NUMBER: ISSUED FOR: DRWNREV DESCRIPTION DES./QADATE CC T - M O B I L E N A T I O N A L A N T E N N A A M E N D M E N T _20 2 4 - 1 2 - 3 1 T-MOBILE SITE NUMBER: IE05397B BU #: 824709 CROWN CASTLE SITE NAME: IE397 MIHAI PINE 2401 EL MONTE AVENUE ARCADIA, CA 91007 EXISTING 50'-0" MONOPOLE 0 01/29/25 TMK MCKCONSTRUCTION 421 FAYETTEVILLE ST, SUITE 600 RALEIGH, NC 27601 1 02/17/25 DMW MCKCONSTRUCTION 2 03/10/25 DMW MCKCONSTRUCTION 3 04/23/25 DMW MCKCONSTRUCTION 04/23/25Exp. 03/31/27 Crown Castle 2000 Corporate Drive Canonsburg,PA 15317 (724)416-2000 Structural Analysis Report T-Mobile Co-Locate Site Number:IE05397B Date: December 26, 2024 Subject: Carrier Designation: Crown Castle Designation:BU Number:824709 Site Name:IE397 Mihai Pine JDE Job Number:2134046 Work Order Number:2351097 Order Number:689059 Rev.0 Engineering Firm Designation:Crown Castle Project Number:2351097 Site Data:2401 El Monte Avenue,Arcadia,Los Angeles County,CA Latitude:34°6’40”Longitude:-118°2’18.72” 50.0 ft -Monopole Tower Crown Castle is pleased to submit this “Structural Analysis Report”to determine the structural integrity of the above-mentioned tower. The purpose of the analysis is to determine acceptability of the tower stress level.Based on our analysis we have determined the tower stress level for the structure and foundation,under the following load case,to be: This analysis has been performed in accordance with the 2022 CBC based upon an ultimate 3-second gust wind speed of 95 mph. Applicable Standard references and design criteria are listed in Section 2 – Analysis Criteria. Structural analysis prepared by: Blake Jacobsen, EIT Respectfully submitted by: Rohit Soni, P.E. Senior Project Engineer LC5:Proposed Equipment Configuration Sufficient Capacity Digitally signed by Rohit Soni Date: 2024.12.26 23:59:27 -05'00' 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 2 tnxTower Report –version 8.2.4.3 TABLE OF CONTENTS 1)INTRODUCTION 2)ANALYSIS CRITERIA Table 1 -Proposed Equipment Configuration 3)ANALYSIS PROCEDURE Table 2 -Documents Provided 3.1)Analysis Method 3.2)Assumptions 4)ANALYSIS RESULTS Table 3 -Section Capacity (Summary) Table 4 -Tower Component Stresses vs.Capacity -LC5 4.1)Recommendations 5)APPENDIX A tnxTower Output 6)APPENDIX B Base Level Drawing 7)APPENDIX C Additional Calculations 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 3 tnxTower Report –version 8.2.4.3 1)INTRODUCTION This tower is a 50.0 ft Monopole Tower designed by Larson Camouflage,and mapped by Paul J.Ford. 2)ANALYSIS CRITERIA TIA-222 Revision:TIA-222-H Risk Category:II Wind Speed:95 mph Exposure Category:B Topographic Factor:1 Seismic Ss:1.917 Seismic S1:0.649 Service Wind Speed:60 mph Table 1 -Proposed Equipment Configuration 3)ANALYSIS PROCEDURE Table 2 -Documents Provided 3.1)Analysis Method tnxTower (version 8.2.4.3),a commercially available analysis software package,was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A.When applicable,Crown Castle has calculated and provided the effective area for panel antennas using approved methods following the intent of the TIA-222 standard. 3.2)Assumptions 1)Tower and structures were maintained in accordance with the TIA-222 Standard. 2)The configuration of antennas,transmission cables,mounts and other appurtenances are as specified in Table 1 and the referenced drawings. Mounting Level (ft) Center Line Elevation (ft) Number of Antennas Antenna Manufacturer Antenna Model Number of Feed Lines Feed Line Size (in) 47 48 3 ericsson AIR6449 B41_T-MOBILE_TIA w/Mount Pipe 2 1-5/847 3 ericsson Radio 4480_TMOV2 3 rfs celwave APXVAALL18_43-U- NA20_TMO_TIA w/Mount Pipe 1 tower mounts T-Arm Mount [TA 601-3] 46 3 ericsson RADIO 4460 B2/B25 B66_TMO Document Reference Source 4-GEOTECHNICAL REPORTS 6458404 CCISITES 4-TOWER FOUNDATION DRAWINGS/DESIGN/SPECS 3865296 CCISITES 4-TOWER MANUFACTURER DRAWINGS 3544926 CCISITES 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 4 tnxTower Report –version 8.2.4.3 This analysis may be affected if any assumptions are not valid or have been made in error.Crown Castle should be notified to determine the effect on the structural integrity of the tower. 4)ANALYSIS RESULTS Table 3 -Section Capacity (Summary) Table 4 -Tower Component Stresses vs.Capacity -LC5 Notes: 1)See additional documentation in “Appendix C –Additional Calculations”for calculations supporting the %capacity consumed 4.1)Recommendations The tower and its foundation have sufficient capacity to carry the considered equipment configuration. No modifications are required at this time. Section No.Elevation (ft)Component Type Size Critical Element P (K)SF*P_allow (K) % Capacity Pass/ Fail L1 50 -0 Pole TP23.5x16x0.25 1 -9.68 1133.22 42.4 Pass Summary Pole (L1)42.4 Pass RATING =42.4 Pass Notes Component Elevation (ft)%Capacity Pass /Fail 1 Anchor Rods 0 45.7 Pass 1 Base Plate 0 43.5 Pass 1 Base Foundation (Structural)0 18.7 Pass 1 Base Foundation (Soil)0 32.6 Pass Structure Rating (max from all components)=45.7% 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 5 tnxTower Report –version 8.2.4.3 APPENDIX A TNXTOWER OUTPUT Crown Castle 2000 Corporate Drive Canonsburg, PA 15317 Phone: 724-416-200 FAX: Job: BU# 824709 Project: Client: Crown Castle Drawn by: jjacobsen App'd: Code: TIA-222-H Date: 12/24/24 Scale: NTS Path: C:\SAPI Work Area\824709\WO 2351097 - SA\Prod\824709.eri Dwg No. E-1 50.0 ft 0.0 ft REACTIONS - 95 mph WIND 9 K SHEAR 285 kip-ft MOMENT 10 K AXIAL SEISMIC 5 K SHEAR 204 kip-ft MOMENT 12 K AXIAL ARE FACTORED ALL REACTIONS S e c t i o n 1 L e n g t h ( f t ) 50 . 0 0 N u m b e r o f S i d e s 18 T h i c k n e s s ( i n ) 0.2 5 0 0 T o p D i a ( i n ) 16 . 0 0 0 0 B o t D i a ( i n ) 23 . 5 0 0 0 G r a d e A5 7 2 - 6 5 W e i g h t ( K ) 2.6 2.6 MATERIAL STRENGTH GRADE GRADEFy FyFu Fu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower is located in Los Angeles County, California. 2. Tower designed for Exposure B to the TIA-222-H Standard. 3. Tower designed for a 95 mph basic wind in accordance with the TIA-222-H Standard. 4. Deflections are based upon a 60 mph wind. 5. Tower Risk Category II. 6. Topographic Category 1 with Crest Height of 0.00 ft 7. CCISeismic Note: Seismic loads generated by CCISeismic 4.0.2 8. CCISeismic Note: Seismic calculations are in accordance with TIA-222-H-1 9. TOWER RATING: 42.4% 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 6 tnxTower Report –version 8.2.4.3 Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-H standard. The following design criteria apply: Tower is located in Los Angeles County,California. Tower base elevation above sea level:367.00 ft. Basic wind speed of 95 mph. Risk Category II. Exposure Category B. Simplified Topographic Factor Procedure for wind speed-up calculations is used. Topographic Category:1. Crest Height:0.00 ft. Deflections calculated using a wind speed of 60 mph. CCISeismic Note:Seismic loads generated by CCISeismic 4.0.2. CCISeismic Note:Seismic calculations are in accordance with TIA-222-H-1. A non-linear (P-delta)analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Tower analysis based on target reliabilities in accordance with Annex S. Load Modification Factors used:Kes(Fw)=0.95,Kes(Ev and Eh)=1.0. Maximum demand-capacity ratio is:1.05. Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not considered. Options Tapered Pole Section Geometry Consider Moments -Legs Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments -Horizontals √Assume Rigid Index Plate Ignore RedundantMembersin FEA Consider Moments -Diagonals √Use ClearSpansFor Wind Area SR Leg Bolts Resist Compression Use Moment Magnification Use ClearSpansFor KL/r AllLeg Panels Have Same Allowable √Use Code Stress Ratios Retension Guys To Initial Tension Offset Girt At Foundation √Use Code Safety Factors -Guys √Bypass Mast Stability Checks √Consider Feed LineTorque Escalate Ice √Use Azimuth Dish Coefficients Include Angle BlockShear Check Always Use Max Kz √Project Wind Area of Appurtenances Use TIA-222-H Bracing Resist.Exemption Use Special WindProfile √AlternativeAppurt.EPA Calculation Use TIA-222-H TensionSplice Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles LegBoltsAre AtTop OfSection Add IBC .6D+W Combination √Include Shear-Torsion Interaction Secondary HorizontalBraces Leg √Sort Capacity Reports By Component Always Use Sub-CriticalFlow Use Diamond Inner Bracing (4 Sided)Triangulate DiamondInner Bracing Use Top Mounted Sockets SR Members Have Cut Ends Treat Feed Line Bundles AsCylinder √Pole Without Linear Attachments SR Members AreConcentric IgnoreKL/ryFor 60 Deg.Angle Legs Pole With Shroud Or No Appurtenances DistributeLeg Loads AsUniform Use ASCE 10 X-Brace Ly Rules OutsideandInside Corner Radii Are Known Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade L1 50.00-0.00 50.00 18 16.0000 23.5000 0.2500 1.0000 A572-65 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 7 tnxTower Report –version 8.2.4.3 Tapered Pole Properties Feed Line/Linear Appurtenances -Entered As Round Or Flat Feed Line/Linear Appurtenances -Entered As Area Feed Line/Linear Appurtenances Section Areas Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade (65 ksi) Section Tip Dia. in Area in2 I in4 r in C in I/C in3 J in4 It/Q in2 w in w/t L1 16.2083 12.4976 391.6752 5.5912 8.1280 48.1884 783.8657 6.2500 2.3760 9.504 23.8240 18.4489 1259.9498 8.2538 11.9380 105.5411 2521.5575 9.2262 3.6960 14.784 Tower Elevation ft Gusset Area (per face) ft2 Gusset Thickness in Gusset Grade Adjust.Factor Af Adjust. Factor Ar WeightMult.Double Angle StitchBolt Spacing Diagonals in DoubleAngle Stitch Bolt Spacing Horizontals in Double Angle Stitch Bolt Spacing Redundants in L150.00-0.00 1 1 1 Description Face or Leg Allow Shield Exclude From Torque Calculation Component Type Placement ft Total Number Number Per Row Clear Spacing in Width or Diameter in Perimeter in Weight klf *** Description Face or Leg Allow Shield Exclude From Torque Calculation Component Type Placement ft Total Number CAAA ft2/ft Weight klf ****** HB158-21U6S24- xxM_TMO(1-5/8) C No No Inside Pole 47.00 -0.00 2 NoIce 0.00 0.00 *** *** Tower Section Tower Elevation ft Face AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 50.00-0.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.23 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 8 tnxTower Report –version 8.2.4.3 Feed Line Center of Pressure Note:For polesections,centerof pressure calculations do not consider feed line shielding. User Defined Loads -Seismic Section Elevation ft CPX in CPZ in CPXIce in CPZIce in L1 50.00-0.00 0.0000 0.0000 0.0000 0.0000 Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K CCISeismic Tower Section 1-1 45.00 0.00 0.0000 0.11 0.00 0.00 0.41 CCISeismic Tower Section 1-2 35.00 0.00 0.0000 0.12 0.00 0.00 0.32 CCISeismic Tower Section 1-3 25.00 0.00 0.0000 0.13 0.00 0.00 0.22 CCISeismic Tower Section 1-4 15.00 0.00 0.0000 0.14 0.00 0.00 0.12 CCISeismic Tower Section 1-5 5.00 0.00 0.0000 0.16 0.00 0.00 0.03 CCISeismic Branches @ 50'50.00 0.00 0.0000 0.03 0.00 0.00 0.14 CCISeismic Branches @ 41.3'41.30 0.00 0.0000 0.13 0.00 0.00 0.43 CCISeismic Branches @ 26.4'26.40 0.00 0.0000 0.55 0.00 0.00 0.97 CCISeismicericsson Radio 4480_TMOV2 47.00 0.00 0.0000 0.02 0.00 0.00 0.08 CCISeismicericsson Radio 4480_TMOV2 47.00 0.00 0.0000 0.02 0.00 0.00 0.08 CCISeismicericsson Radio 4480_TMOV2 47.00 0.00 0.0000 0.02 0.00 0.00 0.08 CCISeismic ericsson AIR6449 B41_T-MOBILE_TIA w/Mount Pipe 47.00 0.00 0.0000 0.03 0.00 0.00 0.13 CCISeismic ericsson AIR6449 B41_T-MOBILE_TIA w/Mount Pipe 47.00 0.00 0.0000 0.03 0.00 0.00 0.13 CCISeismic ericsson AIR6449 B41_T-MOBILE_TIA w/Mount Pipe 47.00 0.00 0.0000 0.03 0.00 0.00 0.13 CCISeismic rfs celwave APXVAALL18_43-U- NA20_TMO_TIAw/Mount Pipe 47.00 0.00 0.0000 0.04 0.00 0.00 0.14 CCISeismic rfs celwave APXVAALL18_43-U- NA20_TMO_TIAw/Mount Pipe 47.00 0.00 0.0000 0.04 0.00 0.00 0.14 CCISeismic rfs celwave APXVAALL18_43-U- NA20_TMO_TIAw/Mount Pipe 47.00 0.00 0.0000 0.04 0.00 0.00 0.14 CCISeismic ericsson RADIO 4460 B2/B25 B66_TMO 47.00 0.00 0.0000 0.03 0.00 0.00 0.11 CCISeismic ericsson RADIO 4460 B2/B25 B66_TMO 47.00 0.00 0.0000 0.03 0.00 0.00 0.11 CCISeismic ericsson RADIO 4460 B2/B25 B66_TMO 47.00 0.00 0.0000 0.03 0.00 0.00 0.11 CCISeismic (3)tower mounts 6'x 2''Mount Pipe 47.00 0.00 0.0000 0.02 0.00 0.00 0.06 CCISeismic (3)tower mounts 6'x 2''Mount Pipe 47.00 0.00 0.0000 0.02 0.00 0.00 0.06 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 9 tnxTower Report –version 8.2.4.3 Discrete Tower Loads Description Elevation ft Offset From Centroid ft Azimuth Angle ° Ev K Ehx K Ehz K Eh K CCISeismic (3)tower mounts 6'x 2''Mount Pipe 47.00 0.00 0.0000 0.02 0.00 0.00 0.06 CCISeismic tower mounts 4'x2'' Pipe Mount 47.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic tower mounts 4'x2'' Pipe Mount 47.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic tower mounts 4'x2'' Pipe Mount 47.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic tower mounts T-Arm Mount [TA 601-3] 47.00 0.00 0.0000 0.19 0.00 0.00 0.70 CCISeismic (2)rfscelwave HB158-21U6S24-xxM_TMO(1- 5/8)From 0 to 47 (40ftto47ft) 43.50 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic (2)rfscelwave HB158-21U6S24-xxM_TMO(1- 5/8)From 0 to 47 (30ftto40ft) 35.00 0.00 0.0000 0.01 0.00 0.00 0.03 CCISeismic (2)rfscelwave HB158-21U6S24-xxM_TMO(1- 5/8)From 0 to 47 (20ftto30ft) 25.00 0.00 0.0000 0.01 0.00 0.00 0.02 CCISeismic (2)rfscelwave HB158-21U6S24-xxM_TMO(1- 5/8)From 0 to 47 (10ftto20ft) 15.00 0.00 0.0000 0.01 0.00 0.00 0.01 CCISeismic (2)rfs celwave HB158-21U6S24-xxM_TMO(1- 5/8)From 0 to 47 (0ftto10ft) 5.00 0.00 0.0000 0.01 0.00 0.00 0.00 Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft ****** Branches @ 50'C None 0.0000 50.00 Branches @ 41.3'C None 0.0000 41.30 Branches @ 26.4'C None 0.0000 26.40 ***47*** Radio4480_TMOV2 A From Leg 4.00 0.00 0.00 0.0000 47.00 Radio4480_TMOV2 B From Leg 4.00 0.00 0.00 0.0000 47.00 Radio4480_TMOV2 C From Leg 4.00 0.00 0.00 0.0000 47.00 AIR6449 B41_T-MOBILE_TIA w/Mount Pipe A From Leg 4.00 0.00 1.00 0.0000 47.00 AIR6449 B41_T-MOBILE_TIA w/Mount Pipe B From Leg 4.00 0.00 1.00 0.0000 47.00 AIR6449 B41_T-MOBILE_TIA w/Mount Pipe C From Leg 4.00 0.00 0.0000 47.00 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 10 tnxTower Report –version 8.2.4.3 Load Combinations Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft 1.00 APXVAALL18_43-U- NA20_TMO_TIAw/Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 47.00 APXVAALL18_43-U- NA20_TMO_TIAw/Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 47.00 APXVAALL18_43-U- NA20_TMO_TIAw/Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 47.00 RADIO 4460 B2/B25 B66_TMO A From Leg 4.00 0.00 -1.00 0.0000 47.00 RADIO 4460 B2/B25 B66_TMO B From Leg 4.00 0.00 -1.00 0.0000 47.00 RADIO 4460 B2/B25 B66_TMO C From Leg 4.00 0.00 -1.00 0.0000 47.00 (3)6'x 2''Mount Pipe A From Leg 4.00 0.00 0.00 0.0000 47.00 (3)6'x 2''Mount Pipe B From Leg 4.00 0.00 0.00 0.0000 47.00 (3)6'x 2''Mount Pipe C From Leg 4.00 0.00 0.00 0.0000 47.00 4'x2''Pipe Mount A From Leg 4.00 0.00 0.00 0.0000 47.00 4'x2''Pipe Mount B From Leg 4.00 0.00 0.00 0.0000 47.00 4'x2''Pipe Mount C From Leg 4.00 0.00 0.00 0.0000 47.00 T-Arm Mount [TA 601-3]C None 0.0000 47.00 ***38*** ****** ****** ****** ****** ****** Comb. No. Description 1 Dead Only 2 1.2 Dead+1.0 Wind 0 deg -No Ice 3 0.9 Dead+1.0 Wind 0 deg -No Ice 4 1.2 Dead+1.0 Wind 30 deg -No Ice 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 11 tnxTower Report –version 8.2.4.3 Maximum Member Forces Comb. No. Description 5 0.9 Dead+1.0 Wind 30 deg -No Ice 6 1.2 Dead+1.0 Wind 60 deg -No Ice 7 0.9 Dead+1.0 Wind 60 deg -No Ice 8 1.2 Dead+1.0 Wind 90 deg -No Ice 9 0.9 Dead+1.0 Wind 90 deg -No Ice 10 1.2 Dead+1.0 Wind 120 deg -No Ice 11 0.9 Dead+1.0 Wind 120 deg -No Ice 12 1.2 Dead+1.0 Wind 150 deg -No Ice 13 0.9 Dead+1.0 Wind 150 deg -No Ice 14 1.2 Dead+1.0 Wind 180 deg -No Ice 15 0.9 Dead+1.0 Wind 180 deg -No Ice 16 1.2 Dead+1.0 Wind 210 deg -No Ice 17 0.9 Dead+1.0 Wind 210 deg -No Ice 18 1.2 Dead+1.0 Wind 240 deg -No Ice 19 0.9 Dead+1.0 Wind 240 deg -No Ice 20 1.2 Dead+1.0 Wind 270 deg -No Ice 21 0.9 Dead+1.0 Wind 270 deg -No Ice 22 1.2 Dead+1.0 Wind 300 deg -No Ice 23 0.9 Dead+1.0 Wind 300 deg -No Ice 24 1.2 Dead+1.0 Wind 330 deg -No Ice 25 0.9 Dead+1.0 Wind 330 deg -No Ice 26 Dead+Wind 0 deg -Service 27 Dead+Wind 30 deg -Service 28 Dead+Wind 60 deg -Service 29 Dead+Wind 90 deg -Service 30 Dead+Wind 120 deg -Service 31 Dead+Wind 150 deg -Service 32 Dead+Wind 180 deg -Service 33 Dead+Wind 210 deg -Service 34 Dead+Wind 240 deg -Service 35 Dead+Wind 270 deg -Service 36 Dead+Wind 300 deg -Service 37 Dead+Wind 330 deg -Service 38 1.2 Dead+1.0 Ev+1.0 Eh 0 deg 39 0.9 Dead-1.0 Ev+1.0Eh0 deg 40 1.2 Dead+1.0 Ev+1.0 Eh 30 deg 41 0.9 Dead-1.0 Ev+1.0Eh30 deg 42 1.2 Dead+1.0 Ev+1.0 Eh 60 deg 43 0.9 Dead-1.0 Ev+1.0Eh60 deg 44 1.2 Dead+1.0 Ev+1.0 Eh 90 deg 45 0.9 Dead-1.0 Ev+1.0Eh90 deg 46 1.2 Dead+1.0 Ev+1.0 Eh 120 deg 47 0.9 Dead-1.0 Ev+1.0Eh120 deg 48 1.2 Dead+1.0 Ev+1.0 Eh 150 deg 49 0.9 Dead-1.0 Ev+1.0Eh150 deg 50 1.2 Dead+1.0 Ev+1.0 Eh 180 deg 51 0.9 Dead-1.0 Ev+1.0Eh180 deg 52 1.2 Dead+1.0 Ev+1.0 Eh 210 deg 53 0.9 Dead-1.0 Ev+1.0Eh210 deg 54 1.2 Dead+1.0 Ev+1.0 Eh 240 deg 55 0.9 Dead-1.0 Ev+1.0Eh240 deg 56 1.2 Dead+1.0 Ev+1.0 Eh 270 deg 57 0.9 Dead-1.0 Ev+1.0Eh270 deg 58 1.2 Dead+1.0 Ev+1.0 Eh 300 deg 59 0.9 Dead-1.0 Ev+1.0Eh300 deg 60 1.2 Dead+1.0 Ev+1.0 Eh 330 deg 61 0.9 Dead-1.0 Ev+1.0Eh330 deg 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 12 tnxTower Report –version 8.2.4.3 Maximum Reactions Tower Mast Reaction Summary Section No. Elevation ft Component Type Condition Gov. Load Comb. Axial K MajorAxis Moment kip-ft Minor Axis Moment kip-ft L1 50 -0 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 50 -11.75 0.00 -203.83 Max.Mx 8 -9.68 -284.79 0.00 Max.My 2 -9.68 0.00 284.79 Max.Vy 8 8.63 -284.79 0.00 Max.Vx 2 -8.63 0.00 284.79 Max.Torque 16 -0.00 Location Condition Gov. Load Comb. Vertical K Horizontal,X K Horizontal,Z K Pole Max.Vert 50 11.75 0.00 -5.04 Max.Hx 21 7.27 8.62 0.00 Max.Hz 3 7.27 0.00 8.62 Max.Mx 2 284.79 0.00 8.62 Max.Mz 8 284.79 -8.62 0.00 Max.Torsion 12 0.00 -4.31 -7.46 Min.Vert 43 5.20 -4.37 2.52 Min.Hx 9 7.27 -8.62 0.00 Min.Hz 15 7.27 0.00 -8.62 Min.Mx 14 -284.79 0.00 -8.62 Min.Mz 20 -284.79 8.62 0.00 Min.Torsion 16 -0.00 4.31 -7.46 Load Combination Vertical K Shearx K Shearz K Overturning Moment,Mxkip-ft Overturning Moment,Mzkip-ft Torque kip-ft Dead Only 8.07 0.00 0.00 0.00 0.00 0.00 1.2 Dead+1.0 Wind 0 deg -No Ice 9.69 0.00 -8.62 -284.79 0.00 0.00 0.9 Dead+1.0 Wind 0 deg -No Ice 7.27 0.00 -8.62 -283.50 0.00 0.00 1.2 Dead+1.0 Wind 30 deg -No Ice 9.69 4.31 -7.46 -246.63 -142.39 0.00 0.9 Dead+1.0 Wind 30 deg -No Ice 7.27 4.31 -7.46 -245.52 -141.75 0.00 1.2 Dead+1.0 Wind 60 deg -No Ice 9.69 7.46 -4.31 -142.39 -246.63 -0.00 0.9 Dead+1.0 Wind 60 deg -No Ice 7.27 7.46 -4.31 -141.75 -245.52 -0.00 1.2 Dead+1.0 Wind 90 deg -No Ice 9.69 8.62 0.00 0.00 -284.79 0.00 0.9 Dead+1.0 Wind 90 deg -No Ice 7.27 8.62 0.00 0.00 -283.50 0.00 1.2 Dead+1.0 Wind 120 deg - No Ice 9.69 7.46 4.31 142.39 -246.63 0.00 0.9 Dead+1.0 Wind 120 deg - No Ice 7.27 7.46 4.31 141.75 -245.52 0.00 1.2 Dead+1.0 Wind 150 deg - No Ice 9.69 4.31 7.46 246.63 -142.39 -0.00 0.9 Dead+1.0 Wind 150 deg -7.27 4.31 7.46 245.52 -141.75 -0.00 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 13 tnxTower Report –version 8.2.4.3 Load Combination Vertical K Shearx K Shearz K Overturning Moment,Mx kip-ft Overturning Moment,Mz kip-ft Torque kip-ft No Ice 1.2 Dead+1.0 Wind 180 deg - No Ice 9.69 0.00 8.62 284.79 0.00 0.00 0.9 Dead+1.0 Wind 180 deg - No Ice 7.27 0.00 8.62 283.50 0.00 0.00 1.2 Dead+1.0 Wind 210 deg - No Ice 9.69 -4.31 7.46 246.63 142.39 0.00 0.9 Dead+1.0 Wind 210 deg - No Ice 7.27 -4.31 7.46 245.52 141.75 0.00 1.2 Dead+1.0 Wind 240 deg - No Ice 9.69 -7.46 4.31 142.39 246.63 -0.00 0.9 Dead+1.0 Wind 240 deg - No Ice 7.27 -7.46 4.31 141.75 245.52 -0.00 1.2 Dead+1.0 Wind 270 deg - No Ice 9.69 -8.62 0.00 0.00 284.79 0.00 0.9 Dead+1.0 Wind 270 deg - No Ice 7.27 -8.62 0.00 0.00 283.50 0.00 1.2 Dead+1.0 Wind 300 deg - No Ice 9.69 -7.46 -4.31 -142.39 246.63 0.00 0.9 Dead+1.0 Wind 300 deg - No Ice 7.27 -7.46 -4.31 -141.75 245.52 0.00 1.2 Dead+1.0 Wind 330 deg - No Ice 9.69 -4.31 -7.46 -246.63 142.39 -0.00 0.9 Dead+1.0 Wind 330 deg - No Ice 7.27 -4.31 -7.46 -245.52 141.75 -0.00 Dead+Wind 0 deg -Service 8.07 0.00 -3.24 -106.68 0.00 0.00 Dead+Wind 30 deg -Service 8.07 1.62 -2.80 -92.39 -53.34 0.00 Dead+Wind 60 deg -Service 8.07 2.80 -1.62 -53.34 -92.39 0.00 Dead+Wind 90 deg -Service 8.07 3.24 0.00 0.00 -106.68 0.00 Dead+Wind 120 deg -Service 8.07 2.80 1.62 53.34 -92.39 0.00 Dead+Wind 150 deg -Service 8.07 1.62 2.80 92.39 -53.34 0.00 Dead+Wind 180 deg -Service 8.07 0.00 3.24 106.68 0.00 0.00 Dead+Wind 210 deg -Service 8.07 -1.62 2.80 92.39 53.34 0.00 Dead+Wind 240 deg -Service 8.07 -2.80 1.62 53.34 92.39 0.00 Dead+Wind 270 deg -Service 8.07 -3.24 0.00 0.00 106.68 0.00 Dead+Wind 300 deg -Service 8.07 -2.80 -1.62 -53.34 92.39 0.00 Dead+Wind 330 deg -Service 8.07 -1.62 -2.80 -92.39 53.34 0.00 1.2 Dead+1.0 Ev+1.0 Eh 0 deg 11.75 0.00 -5.04 -203.83 0.00 0.00 0.9 Dead-1.0 Ev+1.0Eh0 deg 5.20 0.00 -5.04 -201.05 0.00 0.00 1.2 Dead+1.0 Ev+1.0 Eh 30 deg 11.75 2.52 -4.37 -176.52 -101.91 0.00 0.9 Dead-1.0 Ev+1.0Eh30 deg 5.20 2.52 -4.37 -174.12 -100.53 0.00 1.2 Dead+1.0 Ev+1.0 Eh 60 deg 11.75 4.37 -2.52 -101.91 -176.52 -0.00 0.9 Dead-1.0 Ev+1.0Eh60 deg 5.20 4.37 -2.52 -100.53 -174.12 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 90 deg 11.75 5.04 0.00 0.00 -203.83 0.00 0.9 Dead-1.0 Ev+1.0Eh90 deg 5.20 5.04 0.00 0.00 -201.05 0.00 1.2 Dead+1.0 Ev+1.0 Eh 120 deg 11.75 4.37 2.52 101.91 -176.52 0.00 0.9 Dead-1.0 Ev+1.0Eh120 deg 5.20 4.37 2.52 100.53 -174.12 0.00 1.2 Dead+1.0 Ev+1.0 Eh 150 deg 11.75 2.52 4.37 176.52 -101.91 -0.00 0.9 Dead-1.0 Ev+1.0Eh150 deg 5.20 2.52 4.37 174.12 -100.53 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 180 deg 11.75 0.00 5.04 203.83 0.00 0.00 0.9 Dead-1.0 Ev+1.0Eh180 deg 5.20 0.00 5.04 201.05 0.00 0.00 1.2 Dead+1.0 Ev+1.0 Eh 210 deg 11.75 -2.52 4.37 176.52 101.91 0.00 0.9 Dead-1.0 Ev+1.0Eh210 deg 5.20 -2.52 4.37 174.12 100.53 0.00 1.2 Dead+1.0 Ev+1.0 Eh 240 deg 11.75 -4.37 2.52 101.91 176.52 -0.00 0.9 Dead-1.0 Ev+1.0Eh240 deg 5.20 -4.37 2.52 100.53 174.12 -0.00 1.2 Dead+1.0 Ev+1.0 Eh 270 deg 11.75 -5.04 0.00 0.00 203.83 0.00 0.9 Dead-1.0 Ev+1.0Eh270 deg 5.20 -5.04 0.00 0.00 201.05 0.00 1.2 Dead+1.0 Ev+1.0 Eh 300 deg 11.75 -4.37 -2.52 -101.91 176.52 0.00 0.9 Dead-1.0 Ev+1.0Eh300 deg 5.20 -4.37 -2.52 -100.53 174.12 0.00 1.2 Dead+1.0 Ev+1.0 Eh 330 deg 11.75 -2.52 -4.37 -176.52 101.91 -0.00 0.9 Dead-1.0 Ev+1.0Eh330 deg 5.20 -2.52 -4.37 -174.12 100.53 -0.00 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 14 tnxTower Report –version 8.2.4.3 Solution Summary Load Comb. Sum of AppliedForces Sum of Reactions %ErrorPX K PY K PZ K PX K PY K PZ K 1 0.00 -8.07 0.00 0.00 8.07 0.00 0.000% 2 0.00 -9.69 -8.62 0.00 9.69 8.62 0.000% 3 0.00 -7.27 -8.62 0.00 7.27 8.62 0.000% 4 4.31 -9.69 -7.46 -4.31 9.69 7.46 0.000% 5 4.31 -7.27 -7.46 -4.31 7.27 7.46 0.000% 6 7.46 -9.69 -4.31 -7.46 9.69 4.31 0.000% 7 7.46 -7.27 -4.31 -7.46 7.27 4.31 0.000% 8 8.62 -9.69 0.00 -8.62 9.69 0.00 0.000% 9 8.62 -7.27 0.00 -8.62 7.27 0.00 0.000% 10 7.46 -9.69 4.31 -7.46 9.69 -4.31 0.000% 11 7.46 -7.27 4.31 -7.46 7.27 -4.31 0.000% 12 4.31 -9.69 7.46 -4.31 9.69 -7.46 0.000% 13 4.31 -7.27 7.46 -4.31 7.27 -7.46 0.000% 14 0.00 -9.69 8.62 0.00 9.69 -8.62 0.000% 15 0.00 -7.27 8.62 0.00 7.27 -8.62 0.000% 16 -4.31 -9.69 7.46 4.31 9.69 -7.46 0.000% 17 -4.31 -7.27 7.46 4.31 7.27 -7.46 0.000% 18 -7.46 -9.69 4.31 7.46 9.69 -4.31 0.000% 19 -7.46 -7.27 4.31 7.46 7.27 -4.31 0.000% 20 -8.62 -9.69 0.00 8.62 9.69 0.00 0.000% 21 -8.62 -7.27 0.00 8.62 7.27 0.00 0.000% 22 -7.46 -9.69 -4.31 7.46 9.69 4.31 0.000% 23 -7.46 -7.27 -4.31 7.46 7.27 4.31 0.000% 24 -4.31 -9.69 -7.46 4.31 9.69 7.46 0.000% 25 -4.31 -7.27 -7.46 4.31 7.27 7.46 0.000% 26 0.00 -8.07 -3.24 0.00 8.07 3.24 0.000% 27 1.62 -8.07 -2.80 -1.62 8.07 2.80 0.000% 28 2.80 -8.07 -1.62 -2.80 8.07 1.62 0.000% 29 3.24 -8.07 0.00 -3.24 8.07 0.00 0.000% 30 2.80 -8.07 1.62 -2.80 8.07 -1.62 0.000% 31 1.62 -8.07 2.80 -1.62 8.07 -2.80 0.000% 32 0.00 -8.07 3.24 0.00 8.07 -3.24 0.000% 33 -1.62 -8.07 2.80 1.62 8.07 -2.80 0.000% 34 -2.80 -8.07 1.62 2.80 8.07 -1.62 0.000% 35 -3.24 -8.07 0.00 3.24 8.07 0.00 0.000% 36 -2.80 -8.07 -1.62 2.80 8.07 1.62 0.000% 37 -1.62 -8.07 -2.80 1.62 8.07 2.80 0.000% 38 0.00 -11.75 -5.04 0.00 11.75 5.04 0.000% 39 0.00 -5.20 -5.04 0.00 5.20 5.04 0.000% 40 2.52 -11.75 -4.37 -2.52 11.75 4.37 0.000% 41 2.52 -5.20 -4.37 -2.52 5.20 4.37 0.000% 42 4.37 -11.75 -2.52 -4.37 11.75 2.52 0.000% 43 4.37 -5.20 -2.52 -4.37 5.20 2.52 0.000% 44 5.04 -11.75 0.00 -5.04 11.75 0.00 0.000% 45 5.04 -5.20 0.00 -5.04 5.20 0.00 0.000% 46 4.37 -11.75 2.52 -4.37 11.75 -2.52 0.000% 47 4.37 -5.20 2.52 -4.37 5.20 -2.52 0.000% 48 2.52 -11.75 4.37 -2.52 11.75 -4.37 0.000% 49 2.52 -5.20 4.37 -2.52 5.20 -4.37 0.000% 50 0.00 -11.75 5.04 0.00 11.75 -5.04 0.000% 51 0.00 -5.20 5.04 0.00 5.20 -5.04 0.000% 52 -2.52 -11.75 4.37 2.52 11.75 -4.37 0.000% 53 -2.52 -5.20 4.37 2.52 5.20 -4.37 0.000% 54 -4.37 -11.75 2.52 4.37 11.75 -2.52 0.000% 55 -4.37 -5.20 2.52 4.37 5.20 -2.52 0.000% 56 -5.04 -11.75 0.00 5.04 11.75 0.00 0.000% 57 -5.04 -5.20 0.00 5.04 5.20 0.00 0.000% 58 -4.37 -11.75 -2.52 4.37 11.75 2.52 0.000% 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 15 tnxTower Report –version 8.2.4.3 Non-Linear Convergence Results Load Comb. Sum of AppliedForces Sum of Reactions %ErrorPX K PY K PZ K PX K PY K PZ K 59 -4.37 -5.20 -2.52 4.37 5.20 2.52 0.000% 60 -2.52 -11.75 -4.37 2.52 11.75 4.37 0.000% 61 -2.52 -5.20 -4.37 2.52 5.20 4.37 0.000% Load Combination Converged?Number of Cycles Displacement Tolerance Force Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 4 0.00000001 0.00000001 3 Yes 4 0.00000001 0.00000001 4 Yes 4 0.00000001 0.00006877 5 Yes 4 0.00000001 0.00004390 6 Yes 4 0.00000001 0.00006877 7 Yes 4 0.00000001 0.00004390 8 Yes 4 0.00000001 0.00000001 9 Yes 4 0.00000001 0.00000001 10 Yes 4 0.00000001 0.00006877 11 Yes 4 0.00000001 0.00004390 12 Yes 4 0.00000001 0.00006877 13 Yes 4 0.00000001 0.00004390 14 Yes 4 0.00000001 0.00000001 15 Yes 4 0.00000001 0.00000001 16 Yes 4 0.00000001 0.00006877 17 Yes 4 0.00000001 0.00004390 18 Yes 4 0.00000001 0.00006877 19 Yes 4 0.00000001 0.00004390 20 Yes 4 0.00000001 0.00000001 21 Yes 4 0.00000001 0.00000001 22 Yes 4 0.00000001 0.00006877 23 Yes 4 0.00000001 0.00004390 24 Yes 4 0.00000001 0.00006877 25 Yes 4 0.00000001 0.00004390 26 Yes 4 0.00000001 0.00000001 27 Yes 4 0.00000001 0.00000001 28 Yes 4 0.00000001 0.00000001 29 Yes 4 0.00000001 0.00000001 30 Yes 4 0.00000001 0.00000001 31 Yes 4 0.00000001 0.00000001 32 Yes 4 0.00000001 0.00000001 33 Yes 4 0.00000001 0.00000001 34 Yes 4 0.00000001 0.00000001 35 Yes 4 0.00000001 0.00000001 36 Yes 4 0.00000001 0.00000001 37 Yes 4 0.00000001 0.00000001 38 Yes 4 0.00000001 0.00000001 39 Yes 4 0.00000001 0.00000001 40 Yes 4 0.00000001 0.00005884 41 Yes 4 0.00000001 0.00000001 42 Yes 4 0.00000001 0.00005884 43 Yes 4 0.00000001 0.00000001 44 Yes 4 0.00000001 0.00000001 45 Yes 4 0.00000001 0.00000001 46 Yes 4 0.00000001 0.00005884 47 Yes 4 0.00000001 0.00000001 48 Yes 4 0.00000001 0.00005884 49 Yes 4 0.00000001 0.00000001 50 Yes 4 0.00000001 0.00000001 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 16 tnxTower Report –version 8.2.4.3 Maximum Tower Deflections -Service Wind Critical Deflections and Radius of Curvature -Service Wind Maximum Tower Deflections -Design Wind Critical Deflections and Radius of Curvature -Design Wind 51 Yes 4 0.00000001 0.00000001 52 Yes 4 0.00000001 0.00005884 53 Yes 4 0.00000001 0.00000001 54 Yes 4 0.00000001 0.00005884 55 Yes 4 0.00000001 0.00000001 56 Yes 4 0.00000001 0.00000001 57 Yes 4 0.00000001 0.00000001 58 Yes 4 0.00000001 0.00005884 59 Yes 4 0.00000001 0.00000001 60 Yes 4 0.00000001 0.00005884 61 Yes 4 0.00000001 0.00000001 Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 50 -0 4.225 29 0.5802 0.0000 Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 50.00 Branches@50'29 4.225 0.5802 0.0000 Inf 47.00 Radio 4480_TMOV2 29 3.971 0.5454 0.0000 Inf 45.00 CCISeismic Tower Section 1 -1 29 3.802 0.5222 0.0000 Inf 43.50 CCISeismic (2)rfs celwave HB158- 21U6S24-xxM_TMO(1-5/8)From 0 to 47(40ft to47ft) 29 3.675 0.5048 0.0000 Inf 41.30 Branches@41.3'29 3.490 0.4792 0.0000 Inf 35.00 CCISeismic Tower Section 1 -2 29 2.957 0.4061 0.0000 Inf 26.40 Branches@26.4'29 2.231 0.3063 0.0000 Inf 25.00 CCISeismic Tower Section 1 -3 29 2.112 0.2901 0.0000 Inf 15.00 CCISeismic Tower Section 1 -4 29 1.267 0.1741 0.0000 Inf 5.00 CCISeismic Tower Section 1 -5 29 0.422 0.0580 0.0000 Inf Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 50 -0 11.289 2 1.5511 0.0000 Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 17 tnxTower Report –version 8.2.4.3 Compression Checks Pole Design Data Pole Bending Design Data Pole Shear Design Data Pole Interaction Design Data Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 50.00 Branches@50'2 11.289 1.5511 0.0000 Inf 47.00 Radio 4480_TMOV2 2 10.612 1.4580 0.0000 Inf 45.00 CCISeismic Tower Section 1 -1 2 10.160 1.3960 0.0000 Inf 43.50 CCISeismic (2)rfs celwave HB158- 21U6S24-xxM_TMO(1-5/8)From 0 to 47(40ft to47ft) 2 9.822 1.3494 0.0000 Inf 41.30 Branches@41.3'2 9.325 1.2812 0.0000 Inf 35.00 CCISeismic Tower Section 1 -2 2 7.902 1.0858 0.0000 Inf 26.40 Branches@26.4'2 5.961 0.8190 0.0000 Inf 25.00 CCISeismic Tower Section 1 -3 2 5.645 0.7755 0.0000 Inf 15.00 CCISeismic Tower Section 1 -4 2 3.387 0.4653 0.0000 Inf 5.00 CCISeismic Tower Section 1 -5 2 1.129 0.1551 0.0000 Inf Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K fPn K Ratio Pu fPn L1 50 -0 (1)TP23.5x16x0.25 50.00 0.00 0.0 18.4489 -9.68 1079.26 0.009 Section No. Elevation ft Size Mux kip-ft fMnx kip-ft Ratio Mux fMnx Muy kip-ft fMny kip-ft Ratio Muy fMny L1 50 -0 (1)TP23.5x16x0.25 284.79 653.43 0.436 0.00 653.43 0.000 Section No. Elevation ft Size Actual Vu K fVn K Ratio Vu fVn Actual Tu kip-ft fTn kip-ft Ratio Tu fTn L1 50 -0 (1)TP23.5x16x0.25 8.63 323.78 0.027 0.00 659.25 0.000 Section No. Elevation ft Ratio Pu fPn Ratio Mux fMnx Ratio Muy fMny Ratio Vu fVn Ratio Tu fTn Comb. Stress Ratio Allow. Stress Ratio Criteria L1 50 -0 (1)0.009 0.436 0.000 0.027 0.000 0.446 1.050 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 18 tnxTower Report –version 8.2.4.3 Section Capacity Table Section No. Elevation ft Ratio Pu fPn Ratio Mux fMnx Ratio Muy fMny Ratio Vu fVn Ratio Tu fTn Comb. Stress Ratio Allow. Stress Ratio Criteria Section No. Elevation ft Component Type Size Critical Element P K øPallowK % Capacity Pass Fail L1 50 -0 Pole TP23.5x16x0.25 1 -9.68 1133.22 42.4 Pass Summary Pole (L1)42.4 Pass RATING =42.4 Pass 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 19 tnxTower Report –version 8.2.4.3 APPENDIX B BASE LEVEL DRAWING 50.0 ft Monopole Tower Structural Analysis December 24,2024 Project Number 2351097,Order 689059,Revision 0 CCI BU No.824709 Page 20 tnxTower Report –version 8.2.4.3 APPENDIX C ADDITIONAL CALCULATIONS Monopole Base Plate Connection *TIA-222-H Section 15.5 Applied #VALUE! Anchor Rod Data Anchor Rod Summary (units of kips, kip-in) (4) 2-1/4" ø bolts (A615-75 N; Fy=75 ksi, Fu=100 ksi) on 30.5" BC Pu_t = 109.38 φPn_t = 243.75 Stress Rating Vu = 2.16 φVn = 149.1 42.7% Base Plate Data Mu = n/a φMn = n/a Pass 36.5" OD x 2" Plate (A572-50; Fy=50 ksi, Fu=65 ksi) Base Plate Summary Stiffener Data Max Stress (ksi):20.56 (Flexural) N/A Allowable Stress (ksi):45 Stress Rating:43.5%Pass Pole Data 23.5" x 0.25" 18-sided pole (A572-65; Fy=65 ksi, Fu=80 ksi) Analysis ResultsConnection Properties Iar (in) 0.5 Moment (kip-ft) 284.79 Axial Force (kips) 9.68 Shear Force (kips) 8.63 Moment (kip-ft) Axial Force (kips) Shear Force (kips) 0.00 BU # 824709 Applied Loads Site Name IE397 Mihal Pine Order # 689059 REV. 0 Analysis Considerations Site Info TIA-222 Revision H Grout Considered:No 9.68 8.63 Adjusted Pole Reactions Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 Analysis Date: 12/24/2024CCIplate - Version 5.0.2 Monopole Base Plate Connection - Seismic *TIA-222-H Section 15.5 Applied *1.5 Overstrength Factor Applied #VALUE! Anchor Rod Data Anchor Rod Summary (units of kips, kip-in) (4) 2-1/4" ø bolts (A615-75 N; Fy=75 ksi, Fu=100 ksi) on 30.5" BC Pu_t = 117.09 φPn_t = 243.75 Stress Rating Vu = 1.89 φVn = 149.1 45.7% Base Plate Data Mu = n/a φMn = n/a Pass 36.5" OD x 2" Plate (A572-50; Fy=50 ksi, Fu=65 ksi) Base Plate Summary Stiffener Data Max Stress (ksi):14.93 (Flexural) N/A Allowable Stress (ksi):45 Stress Rating:31.6%Pass Pole Data 23.5" x 0.25" 18-sided pole (A572-65; Fy=65 ksi, Fu=80 ksi) Site Info BU # 824709 Site Name IE397 Mihal Pine Moment (kip-ft) 203.83 Order # 689059 REV. 0 Analysis Considerations TIA-222 Revision H Grout Considered:No Iar (in) 0.5 Applied Loads Analysis Results Axial Force (kips) 11.75 Shear Force (kips) 5.04 Adjusted Pole Reactions Moment (kip-ft) 0.00 Axial Force (kips) 11.75 Shear Force (kips) 5.04 Connection Properties Show image? Plate Dia. Shaft Dia. Pole Shape Plate Type: Plate Geometry: Plate Quantity Plate Dia. 2 Shaft Dia. 2 Analysis Date: 12/24/2024CCIplate - Version 5.0.2 Report File: TIA-222 Revison: Tower Type:Check Pier Capacity only at location of Max Moment?No Location: Soil Lateral Check Compression Uplift Comp.Uplift 6.58 - 284.79 7.60 - 9.69 330.86 - 8.62 16.7%- Soil Vertical Check Compression Uplift Go to Soil Calculations 154.45 - 3 ksi 85.53 - 60 ksi 72.45 - 40 ksi 239.98 - 82.14 - 32.6%- 20 ft Reinforced Concrete Flexure Compression Uplift 0.5 ft 6.42 - 330.81 - 1684.96 - 5 ft 18.7%- 27 12 Reinforced Concrete Shear Compression Uplift 10 15.22 - 4 in 50.88 - 4 319.01 - 8 in 15.2%- in *Rating per TIA-222-H Section 15.5 N/A # of Layers 6 121 FALSE 1 0 2.5 2.5 122.591 150 0 0 0.000 0.000 0.00 0.00 FALSE 2 2.5 3 0.5 122.591 150 0 23 0.402 0.402 14 FALSE 3 3 5 2 127.514 150 0 23 0.569 0.569 14 FALSE 4 5 10 5 129.154 150 0 23 0.214 0.214 3 FALSE 5 10 15 5 118.01 150 0 23 1.066 1.066 10 FALSE 6 15 20 5 118.231 150 0 23 1.075 1.075 5.808 8 Shear Force (kips)Rating* Utilize Shear-Friction Methodology: Check Limitation Override Critical Depth: Check Shear along Depth of Pier: N/A Design Options Input Effective Depths (else Actual): Apply TIA-222-H Section 15.5:Monopole Monopole Analysis Results Applied Loads Dv=0 (ft from TOC) Soil Safety FactorMoment (kip-ft) Max Moment (kip-ft)Axial Force (kips) Consider non-tapered moment capacity: Drilled Pier Foundation BU # :824709 C:\SAPI Work Area\824709\WO 2351097 - SA\Prod\824709.eri.XMLOUT.xmlIE397 Mihal PineSite Name: 689059 REV. 0Order Number: H Rebar Size Critical Depth (ft from TOC) Clear Cover to Ties Critical Shear (kip) Critical Shear CapacityTie Size Rating*Tie Spacing Rebar 2, Fy Override (ksi) Rebar 3, Fy Override (ksi) Material Properties Skin Friction (kips) Concrete Strength, f'c:End Bearing (kips) Rebar Strength, Fy:Weight of Concrete (kips) Tie Yield Strength, Fyt:Total Capacity (kips) Axial (kips) Pier Design Data Rating* Depth Ext. Above Grade Critical Depth (ft from TOC) Critical Moment (kip-ft)Pier Section 1 From 0.5' above grade to 20' below grade Critical Moment Capacity Pier Diameter Rating* Rebar Quantity Rebar Quantity Structural Foundation Rating*Rebar Size 18.7% Rebar Cage Diameter Soil Interaction Rating*32.6% Layer Soil TypeTop (ft) Cohesionless Soil Profile Groundwater Depth SPT Blow Count Ult. Gross Bearing Capacity (ksf) Ultimate Skin Friction Uplift Override (ksf) Ultimate Skin Friction Comp Override (ksf) Calculated Ultimate Skin Friction Uplift (ksf) Calculated Ultimate Skin Friction Comp (ksf) Angle of Friction (degrees) γconcrete (pcf) γsoil (pcf) Cohesion (ksf)Bottom (ft)Thickness (ft) Cohesionless Cohesionless Cohesionless Cohesionless Cohesionless Rebar & Pier Options Embedded Pole Inputs Belled Pier Inputs Version 6.3.6 BU:824709 Structure:A WO:2351097 Order:Rev: Decimal Degrees Deg Min Sec ###Lat:34.111111 +34 6 40.00 ###Long:-118.038533 -118 2 18.72 Seismic Design Code:TIA-222-H-1 ###Site Soil:D (Determined)Stiff Soil Risk Category:II ###USGS Seismic Reference SS:1.9170 g ###S1:0.6490 g TL:8 s 1 Importance Factor, Ie:1 Acceleration-based site coefficient, Fa:1.0000 Velocity-based site coefficient, Fv:1.7000 Design spectral response acceleration short period, SDS:1.2780 g Design spectral response acceleration 1 s period, SD1:0.7355 g Ts:0.5755 Seismic Design Category Based on SDS:D Seismic Design Category Based on SD1:D Seismic Design Category Based on S1:N/A Controlling Seismic Design Category:D Location Code and Site Parameters Seismic Design Category Determination CCISeismic 4.0.2 Page 1 Analysis Date: 12/24/2024 BU:824709 Structure:A WO:2351097 Order:Rev: Tower Type:Tapered Monopole Height, h:50 ft ###Effective Seismic Weight, W:8.07 kips Amplification Factor, As:1.0 2.7.8.1 ###Response Modification Factor, R:1.5 ###1.178005969 Discrete Appurtenance Weight in Top 1/3 of Structure, Wu:3.036 kips WL:5.03650672 kips E:29000.0 ksi g:386.088 in/s2 Average Moment of Inertia, Iavg:772.8587827 in4 Fa:0.848892133 hz Approximate Fundamental Period Monopole, Ta:1.1780 s 2.7.7.1.3.3 Seismic Response Coefficient, Cs 0.6244 Table 2-12 Note 3 Seismic Response Coefficient Max 1, Csmax N/A Seismic Response Coefficient Max 2, Csmax N/A Seismic Response Coefficient Min 1, Csmin 0.0562 2.7.7.1.1 Seismic Response Coefficient Min 2, Csmin 0.3461 2.7.7.1.1 Controlling Seismic Response Coefficient, Csc 0.6244 Seismic Base Shear, V 5.040 kips 2.7.7.1.1 Period Related Exponent, k:1.339 Sum of wihi k 900.20 ### Tower Details Seismic Base Shear Vertical Distribution Factors CCISeismic 4.0.2 Page 2 Analysis Date: 12/24/2024 Section Number Length Top Height Mid Height, hx Section Weight, wx wxhxk Cvx Fxh Fxv 1 - 1 10.00 50.00 45.00 0.4455 72.86 0.0809 0.4080 0.1139 1 - 2 10.00 40.00 35.00 0.4860 56.77 0.0631 0.3179 0.1242 1 - 3 10.00 30.00 25.00 0.5265 39.20 0.0435 0.2195 0.1346 1 - 4 10.00 20.00 15.00 0.5670 21.30 0.0237 0.1193 0.1449 1 - 5 10.00 10.00 5.00 0.6075 5.24 0.0058 0.0293 0.1553 Sum 2.6325 195.37 Tower Section Loads CCISeismic 4.0.2 Page 3 Analysis Date: 12/24/2024 Name hx wx wxhxk Cvx Fxh Fxv Branches @ 50'50.00 0.1330 25.05 0.0278 0.1402 0.0340 Branches @ 41.3'41.30 0.5270 76.84 0.0854 0.4302 0.1347 Branches @ 26.4'26.40 2.1690 173.70 0.1930 0.9726 0.5544 ericsson Radio 4480_TMOV2 47.00 0.0800 13.87 0.0154 0.0777 0.0204 ericsson Radio 4480_TMOV2 47.00 0.0800 13.87 0.0154 0.0777 0.0204 ericsson Radio 4480_TMOV2 47.00 0.0800 13.87 0.0154 0.0777 0.0204 ericsson AIR6449 B41_T-MOBILE_TIA w/ Mount Pipe 47.00 0.1300 22.54 0.0250 0.1262 0.0332 ericsson AIR6449 B41_T-MOBILE_TIA w/ Mount Pipe 47.00 0.1300 22.54 0.0250 0.1262 0.0332 ericsson AIR6449 B41_T-MOBILE_TIA w/ Mount Pipe 47.00 0.1300 22.54 0.0250 0.1262 0.0332 rfs celwave APXVAALL18_43-U-NA20_TMO_TIA w/ Mount Pipe 47.00 0.1400 24.27 0.0270 0.1359 0.0358 rfs celwave APXVAALL18_43-U-NA20_TMO_TIA w/ Mount Pipe 47.00 0.1400 24.27 0.0270 0.1359 0.0358 rfs celwave APXVAALL18_43-U-NA20_TMO_TIA w/ Mount Pipe 47.00 0.1400 24.27 0.0270 0.1359 0.0358 ericsson RADIO 4460 B2/B25 B66_TMO 47.00 0.1100 19.07 0.0212 0.1068 0.0281 ericsson RADIO 4460 B2/B25 B66_TMO 47.00 0.1100 19.07 0.0212 0.1068 0.0281 ericsson RADIO 4460 B2/B25 B66_TMO 47.00 0.1100 19.07 0.0212 0.1068 0.0281 (3) tower mounts 6' x 2" Mount Pipe 47.00 0.0600 10.40 0.0116 0.0582 0.0153 (3) tower mounts 6' x 2" Mount Pipe 47.00 0.0600 10.40 0.0116 0.0582 0.0153 (3) tower mounts 6' x 2" Mount Pipe 47.00 0.0600 10.40 0.0116 0.0582 0.0153 tower mounts 4' x 2" Pipe Mount 47.00 0.0300 5.20 0.0058 0.0291 0.0077 tower mounts 4' x 2" Pipe Mount 47.00 0.0300 5.20 0.0058 0.0291 0.0077 tower mounts 4' x 2" Pipe Mount 47.00 0.0300 5.20 0.0058 0.0291 0.0077 tower mounts T-Arm Mount [TA 601-3]47.00 0.7260 125.86 0.1398 0.7047 0.1856 Sum 5.2050 687.48 Discrete Loads CCISeismic 4.0.2 Page 4 Analysis Date: 12/24/2024 Name Start Height End Height hx wx wxhxk Cvx Fxh Fxv (2) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 47 40.00 47.00 43.50 0.0350 5.47 0.0061 0.0306 0.0089 (2) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 47 30.00 40.00 35.00 0.0500 5.84 0.0065 0.0327 0.0128 (2) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 47 20.00 30.00 25.00 0.0500 3.72 0.0041 0.0208 0.0128 (2) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 47 10.00 20.00 15.00 0.0500 1.88 0.0021 0.0105 0.0128 (2) rfs celwave HB158-21U6S24-xxM_TMO(1-5/8) From 0 to 47 0.00 10.00 5.00 0.0500 0.43 0.0005 0.0024 0.0128 Sum 0.2350 17.34 Linear Loads CCISeismic 4.0.2 Page 5 Analysis Date: 12/24/2024 ASCE Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-16 Latitude:34.111111 Risk Category:II Longitude:-118.038533 Soil Class:D - Stiff Soil Elevation:371.52699535671127 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Tue Dec 24 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Tue Dec 24 2024 SS : 1.917 S1 : 0.649 Fa : 1 Fv : N/A SMS : 1.917 SM1 : N/A SDS : 1.278 SD1 : N/A TL : 8 PGA : 0.828 PGA M : 0.911 FPGA : 1.1 Ie : 1 Cv : 1.483 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Stiff Soil USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Tue Dec 24 2024 Page 2 of 3https://ascehazardtool.org/Tue Dec 24 2024 Ice Results: Data Source: Date Accessed: Ice Thickness: 0 in. Concurrent Temperature: 25 F Gust Speed 30 mph Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Tue Dec 24 2024 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Tue Dec 24 2024