HomeMy WebLinkAbout400 S Baldwin Ave - 2025 - Marketing OfficeT101 TITLE SHEET SYMBOL LEGEND ABBREVIATIONS GENERAL PROJECT DATA PROJECT TEAM 1.ALL WORK PERFORMED AND MATERIAL PROVIDED BY THE CONTRACTOR SHALL CONFORM TO THE LATEST APPLICABLE BUILDING CODES AND CONSTRUCTION STANDARDS, WHETHER OR NOT SPECIFIED ON THE DOCUMENTS. 2. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DOCUMENTS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR DEFINITION, THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION. 3. THE 'GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION', STANDARD FORM A201 OF THE AMERICAN INSTITUTE OF ARCHITECTS, LATEST EDITION, ARE MADE A PART OF THE CONSTRUCTION DOCUMENTS, AND SHALL APPLY TO THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS. 4. THESE DOCUMENTS ARE INTENDED TO CONVEY THE GENERAL DESIGN INTENT. THE HIGHEST LEVEL OF MATERIAL AND WORKMANSHIP SHALL BE USED THROUGHOUT. ALL CONSTRUCTION DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS CALLED FOR BY ANY WILL BE PROVIDED AS IF CALLED FOR BY ALL. 5. AT THE TIME OF BID SUBMITTAL, THE CONTRACTOR SHALL ADVISE ARCHITECT, IN WRITING, OF ANY SPECIFIED MATERIALS OR EQUIPMENT WHICH ARE EITHER UNAVAILABLE OR WILL CAUSE A DELAY IN THE COMPLETION OF CONSTRUCTION. NO SUBSTITUTIONS OF SPECIFIED MATERIALS SHALL BE PERMITTED WITHOUT FIRST SUBMITTING SPECIFICATIONS, SAMPLES, AND FOR THE ARCHITECT'S REVIEW. 6. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AT JOB SITE PRIOR TO COMMENCEMENT OF ANY WORK, AND SHALL REQUEST CLARIFICATION FROM THE ARCHITECT IMMEDIATELY FOR ANY DISCREPANCIES OR OMISSIONS BETWEEN THE DOCUMENTS AND FIELD CONDITIONS. THE MOST STRINGENT REQUIREMENT OF THE CONSTRUCTION DOCUMENTS, OR APPLICABLE CODES OR STANDARDS, SHALL GOVERN. 7. ALL DIMENSIONS GIVEN ARE FROM CENTERLINE OF BEAM OR COLUMN, OR FROM FACE OF FRAMING OR FACE OF MASONRY TYPICAL, UNLESS NOTED OTHERWISE. DO NOT SCALE DRAWINGS! DIMENSIONS GOVERN, AND LARGE SCALE DETAILS GOVERN OVER SMALLER SCALE DETAILS. IF DIMENSIONAL DISCREPANCIES ARE ARE DISCOVERED, THE CONTRACTOR SHALL BRING THEM TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY FOR CLARIFICATION. 8. SOLELY AS A CONVENIENCE TO THE OWNER, THE ARCHITECT MAY INCLUDE DOCUMENTS PREPARED BY THE OWNER'S OTHER CONSULTANTS (I.E.: SOILS REPORT), OR INCORPORATE THE RECOMMENDATIONS OF SAID CONSULTANTS INTO THE DOCUMENTS PREPARED OR ISSUED BY THE ARCHITECT. IT IS EXPRESSLY UNDERSTOOD THAT, BY SUCH ISSUANCE, THE ARCHITECT ASSUMES NO LIABILITY FOR THE SERVICES OF SAID CONSULTANTS. 9. THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DOCUMENTS ON-SITE DURING ALL PHASES OF THE WORK. THE CONTRACTOR SHALL SEE THAT ALL SUB-CONTRACTORS RECEIVE THE LATEST CONSTRUCTION DOCUMENTS. 10. THE CONTRACTOR, AND THE SUB-CONTRACTORS, SHALL REVIEW THE CONSTRUCTION DOCUMENTS FOR ISSUES RELATED TO EACH TRADE PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL SUB-CONTRACTORS, AND REPORT ANY DISCREPANCIES IMMEDIATELY TO THE ARCHITECT FOR CLARIFICATION. 11. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS NECESSARY FOR THE EXECUTION AND COMPLETION OF THE WORK. FORWARD COPIES OF ALL EXECUTED PERMITS TO THE ARCHITECT. 12. THE CONTRACTOR SHALL COORDINATE AND SCHEDULE ALL INSPECTIONS OR TESTS INDICATED ON THE CONSTRUCTION DOCUMENTS OR REQUIRED BY ANY GOVERNMENT AGENCY. THE OWNER WILL HIRE THE TESTING SERVICE(S) OR INSPECTOR(S) DIRECTLY. 13. THE CONTRACTOR SHALL HAVE A REGISTERED CIVIL ENGINEER CERTIFY ALL THE BUILDING PAD ELEVATIONS TO THE CITY OF ARCADIA, THE OWNER, AND THE ARCHITECT. 14. THE CONTRACTOR SHALL PROVIDE PUBLIC PROTECTION AS REQUIRED BY CITY AGENCIES, AND SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOBSITE CONDITIONS DURING THE COURSE OF CONSTRUCTION, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL PROTECT IN PLACE ALL EXISTING SURFACES TO REMAIN, AND SHALL PATCH, REPAIR, OR REPLACE ANY EXISTING SURFACES DAMAGED DURING DEMOLITION OR CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. 15. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION, ALL REQUIRED EXIT WAYS, SIGNS, LIGHTING, FIRE PROTECTION DEVICES, AND ALARMS FROM THE BUILDING TO THE PUBLIC WAY SHALL BE CONTINUOUSLY MAINTAINED. 16. IF THERE ARE TRENCHES OR EXCAVATIONS 5'-0" OR MORE IN DEPTH INTO WHICH A PERSON MUST DESCEND, OR IF THERE IS ANY DEMOLITION OR CONSTRUCTION OF ANY BUILDING, STRUCTURE, SCAFFOLDING, OR FALSEWORK MORE THAN THREE STORIES OR 36'-0" IN HEIGHT, THE CONTRACTOR SHALL OBTAIN THE NECESSARY PERMIT(S) FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 17. THE CONTRACTOR IS WHOLLY RESPONSIBLE FOR SCHEDULING OF THE WORK REQUIRED TO COMPLETE THE JOB. THE CONTRACTOR SHALL COORDINATE ALL PERMITS, SHOP DRAWINGS, SPECIAL FABRICATIONS, AND VENDOR SUPPLIED ITEMS WITH THE PROJECT SCHEDULE. 18. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER OR BUILDING MANAGEMENT TO DETERMINE THE CONDITIONS FOR CONSTRUCTION, DELIVERIES, OR OTHER TASKS TO BE PERFORMED OUTSIDE REGULAR BUSINESS HOURS, AND ANY OTHER SPECIAL BUILDING REQUIREMENTS WHICH WILL AFFECT THE WORK. EVENING OR NIGHT WORK, OR PHASED CONSTRUCTION SHALL BE INCLUDED IN THE PROJECT SCOPE. THE TENANTS SHALL REMAIN OPEN FOR BUSINESS DURING CONSTRUCTION. ACCESS TO SUITES AND ALL UTILITY SERVICES SHALL BE MAINTAINED DURING THEIR NORMAL BUSINESS HOURS. 19. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EMBEDDED ITEMS BEFORE POURING CONCRETE, AND SHALL NOTIFY THE ARCHITECT AND OWNER ONE WEEK IN ADVANCE OF THE SLAB POUR DATE. 20. THE CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL EXISTING UTILITY LINES AND STUBS TO THE BUILDING(S). THE CONTRACTOR SHALL EXTEND ALL UTILITY LINES FROM OUTSIDE THE BUILDING, OR FROM POINTS-OF-CONNECTION, AS INDICATED ON THE CONSTRUCTION DOCUMENTS. 21. SIZES AND LOCATIONS OF ALL EQUIPMENT ARE GIVEN AS A BASIS-OF-DESIGN ONLY. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS, LOCATIONS, AND REQUIREMENTS OF ALL EQUIPMENT WITH MANUFACTURER'S OR SUPPLIER'S PUBLISHED DATA, AND SHALL VERIFY THE SIZES AND LOCATIONS OF ALL FLOOR, WALL, AND ROOF OPENINGS PRIOR TO THE START OF RELATED WORK. 22. THE CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING, HANGERS, OR OTHER SUPPORT FOR ALL FIXTURES, EQUIPMENT, CABINETRY, FURNISHINGS, OR SIMILAR ITEMS AS REQ'D. 23. THE CONTRACTOR SHALL PROMPTLY REMOVE ALL RUBBISH OR WASTE MATERIALS FROM THE JOBSITE. THE CONTRACTOR SHALL PROVIDE CONTAINMENT TO PREVENT DIRT OR DUST FROM LEAVING THE J0BSITE AS DIRECTED BY CITY AGENCIES. 24. ALL ITEMS ARE NEW, U.N.O. ALL EXISTING, RELOCATED, OR NEW ITEMS SHALL BE THOROUGHLY CLEANED PRIOR TO TURN OVER TO THE OWNER. 25. INSURANCE AND BONDING FOR THE PROJECT SHALL BE AS DIRECTED BY AND TO THE SATISFACTION OF THE OWNER. 26. CONTRACT CLOSE-OUT SHALL OCCUR ONLY AFTER THE ARCHITECT'S PUNCH LIST ITEMS HAVE BEEN CORRECTED. THE CONTRACTOR SHALL SUBMIT GUARANTEES AND WARRANTEES, MAINTENANCE MANUALS, RELEASE OF LIENS, AS-BUILT DRAWINGS, AND RELATED CLOSE-OUT DOCUMENTS TO THE ARCHITECT WITH HIS FINAL APPLICATION FOR PAYMENT. 27. PROVIDE METAL CORNER BEAD AT ALL EDGES OF PLASTER OR DRYWALL, AND METAL TRIM OR CASING BEAD AT ALL EDGES OF PLASTER OR DRYWALL, WHERE THEY MEET OR TERMINATE AGAINST ANY OTHER MATERIAL, U.N.O. ALL EXTERIOR OR INTERIOR EXPOSED FLASHINGS, TRIM, ETC., SHALL BE PAINTED TO MATCH ADJACENT MATERIALS, U.N.O. THE CONTRACTOR SHALL PROVIDE SOLID BLOCKING AS REQUIRED FOR ATTACHMENT OF ALL EXTERIOR OR INTERIOR TRIMS, FINISHES, FIXTURES, ETC., AND SHALL PROVIDE NECESSARY FRAMING AND BRACING FOR THE INSTALLATION OF NOTED EQUIPMENT. 28. ALL HVAC DUCTWORK, ELECTRICAL CONDUITS, PIPING, ETC., SHALL BE RUN IN THE SOFFITS, ATTICS, FURRING, OR OTHER CONCEALED SPACES OF THE BUILDING, U.N.O. EXPOSED WORK IN FINISHED AREAS WILL NOT BE ACCEPTED. KEEP PIPING AND CONDUITS AS CLOSE TO WALLS AND UNDERSIDE OF FLOORS AND ROOFS AS POSSIBLE. 29. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. OR, AT EACH MAIN EXIT DOOR IN GROUP A (300 OCC. OR LESS), B, F, M, OR S OCCUPANCIES, ATTACH A READILY VISIBLE, DURABLE SIGN STATING: "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". THE SIGN SHALL BE IN 1" HIGH LETTERS ON A CONTRASTING BACKGROUND. THE LOCKING DEVICE MUST BE READILY DISTINGUISHABLE AS LOCKED. 30. EXTERIOR DOORS SHALL RECEIVE DEAD BOLTS AND DEAD LOCKING LATCHES. STRAIGHT DEAD BOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8". CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHEN THE CYLINDER PROJECTS FROM THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. DOOR HINGES SHALL HAVE NON-REMOVABLE PINS. 31. ALL DOOR HARDWARE SHALL BE MOUNTED FROM 30" TO 44" ABOVE THE FLOOR AND SHALL BE OPERABLE BY A SINGLE EFFORT WITH NO GRASPING OR WRIST MOVEMENT (I.E.: LEVERS, PUSH-PULLS, OR PANIC HARDWARE). THE ALLOWABLE CLOSER PRESSURE SHALL NOT EXCEED 5 POUNDS FOR INTERIOR DOORS, 5 POUNDS FOR EXTERIOR DOORS, AND 15 POUNDS FOR FIRE DOORS WITH PANIC HARDWARE. 32. FIRE EXTINGUISHERS (BY TENANT- N.I.C.) MUST BE INSTALLED PRIOR TO BUILDING OCCUPANCY AND SHALL BE RATED 2A 10 BC, PROVIDED AT THE RATE OF ONE (1) PER 3000 SF AND 75'-0" MAXIMUM ON CENTER, OR AS DIRECTED BY THE FIRE INSPECTOR IN THE FIELD. 33. IN A FIRE SPRINKLERED BUILDING, ALL INTERIOR WALL AND CEILING FINISHES SHALL HAVE A CLASS 'C' RATING MINIMUM (FLAME SPREAD 200, SMOKE DEVELOPED 450). EXIT CORRIDOR FINISHES SHALL HAVE A CLASS 'B' RATING MINIMUM (FLAME SPREAD 75). FLOOR FINISHES SHALL HAVE A SLIP-RESISTANT FINISH. 34. ALL INSULATION MATERIALS, INCLUDING FACINGS, INSTALLED IN FLOOR-CEILING AND ROOF-CEILING ASSEMBLIES, WALLS, CRAWL SPACES, OR ATTICS, SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY RATING NOT TO EXCEED 450, EXCEPT THAT FOAM PLASTIC INSULATION SHALL HAVE A FLAME SPREAD RATING NOT MORE THAN 75. 35. ALL EXTERIOR OPENINGS, FLASHINGS, COPINGS, EXPANSION JOINTS, ETC., SHALL BE WEATHERPROOF. ALL EXTERIOR DOORS AND WINDOWS, DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACES, EXTERIOR JOINT PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED, GASKETED, WEATHERSTRIPPED, OR OTHERWISE SEALED TO LIMIT AIR LEAKAGE. PROVIDE A METAL ASTRAGAL AT THE ACTIVE LEAF OF EACH PAIR OF DOORS. 36. BUILDINGS SHALL BE PROVIDED WITH NATURAL VENTILATION BY MEANS OF OPENINGS TO THE OUTDOORS WITH A READILY OPENABLE MINIMUM AREA OF 4% OF FLOOR AREA BEING VENTILATED, OR BY MECHANICAL VENTILATION (SEE MECH. DRAWINGS). 37. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS WITH A MINIMUM NET GLAZED AREA OF 8% OF FLOOR AREA OF THE ROOM SERVED, OR BY ARTIFICIAL LIGHT WITH AN AVERAGE ILLUMINATION OF 10 FOOTCANDLES (107 LUX) OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR (SEE ELECT. DRAWINGS). 38. DOOR OPENINGS NOT DIMENSIONED ARE TO BE LOCATED IN CENTER OF ROOM OR 4" FROM ADJACENT PARTITION, U.N.O. 39. CONTRACTOR SHALL PROVIDE MISCELLANEOUS ACCESS PANELS AS REQUIRED BY CODES. PROVIDE FIRE RATED PANELS AT RATED WALLS AND CEILINGS. AT FIRE RATED WALL ASSEMBLIES, EXTEND PLASTER OR GYPSUM BOARD BEHIND WALL CABINETS, RECESSED FIRE HOSE CABINETS, LIGHT FIXTURES, AND ELECTRICAL PANELS TO MAINTAIN THE FIRE RATING. 40. TEMPORARY OR PERMANENT SIGNAGE REQUIRES SEPARATE APPROVALS AND PERMITS FROM GOVERNING AGENCIES. 41. THE CONTRACTOR SHALL POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE, SIGNED BY THE INSTALLER, STATING THAT WALL, CEILING, AND FLOOR INSULATION INSTALLED IS CONSISTENT WITH THE CONSTRUCTION DOCUMENTS, AND THE MANUFACTURER'S CERTIFICATION TO COMPLY WITH 'CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIAL'. 42. THE CONTRACTOR SHALL POST, ADJACENT TO THE BUILDING PERMIT, INSTALLATION CERTIFICATES FOR MANUFACTURED DEVICES REGULATED BY THE CALIFORNIA APPLIANCE EFFICIENCY STANDARDS, INDICATING FEATURES REQUIRED TO VERIFY COMPLIANCE WITH THE STANDARDS, A STATEMENT THAT INSTALLED DEVICES CONFORM TO THE STANDARDS, REQUIREMENTS FOR SUCH DEVICES IN THE APPROVED PLANS AND SPECIFICATIONS, AND THE PERMIT NUMBER. 43. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A LIST OF THE HEATING, COOLING, WATER HEATING, LIGHTING, AND CONSERVATION SYSTEMS, FEATURES, MATERIALS, COMPONENTS, AND DEVICES INSTALLED IN THE BUILDING, AND INSTRUCTIONS ON HOW TO USE THEM; LABELS ON MANUFACTURED DEVICES CLEARLY STATING ROUTINE MAINTENANCE ACTION; AND A DESCRIPTION OF THE QUANTITIES OF OUTDOOR AND RECIRCULATED AIR THAT THE VENTILATION SYSTEM IS DESIGNED TO PROVIDE EACH AREA. 44. IDENTIFY EACH GAS OR ELECTRIC METER WITH THE NUMBER OF THE SPACE WHICH IT SERVES. 45. AN APPROVED SEISMIC GAS SHUT-OFF VALVE OR EXCESS FLOW SHUT-OFF VALVE SHALL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING (SEPARATE PLUMBING PERMIT). 46. BUILDING ADDRESS NUMBERS SHALL BE PROVIDED ON THE FRONT OF EACH BUILDING, SHALL BE VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY, AND SHALL CONTRAST WITH THEIR BACKGROUND. VERIFY THE REQUIRED HEIGHT, STROKE, COLOR, AND LOCATION OF NUMBERS WITH GOVERNING AGENCIES. 47. PREMISES IDENTIFICATION NUMBERS SHALL BE MOUNTED ON THE FRONT AND REAR (SERVICE) DOORS OF EACH TENANT SPACE. MINIMUM HEIGHT FOR THE LETTERS/NUMBERS SHALL BE 6". CONTRACTOR TO PROVIDE ADHESIVE BACKED VINYL DECALS "WHITE" TYPICAL. 48. EXIT SIGNS (BY TENANT- N.I.C.) SHALL HAVE THE WORD "EXIT" ON THE SIGN IN CAPITAL LETTERS NOT LESS THAN 6" IN HEIGHT WITH A STROKE OF NOT LESS THAN 3/4". EXIT SIGNS SHALL BE INTERNALLY ILLUMINATED, WITH A FACE LUMINANCE EQUIVALENT TO 5 FOOTCANDLES, AND SHALL BE ILLUMINATED AT ALL TIMES. IN CASE OF PRIMARY POWER LOSS, PROVIDE AN EMERGENCY ELECTRICAL SYSTEM PER THE ELECTRICAL CODE. 49. AT ANY TIME THE BUILDING IS OCCUPIED, THE MEANS OF EGRESS SHALL BE ILLUMINATED AT AN INTENSITY OF NOT LESS THAN 1 FOOTCANDLE AT FLOOR LEVEL. IN THE EVENT OF A POWER SUPPLY FAILURE, ILLUMINATION SHALL BE PROVIDED FROM AN EMERGENCY SYSTEM PER THE ELECTRICAL CODE, WHERE THE EGRESS SYSTEM SERVES AN OCCUPANT LOAD OF 100 OR MORE. ELECTRICAL POWER PLANS SHALL INCLUDE WIRING TO EXIT SIGNS AND EMERGENCY ILLUMINATION BY (TENANT- N.I.C.) OF EXIT PATHS. BACK-UP EMERGENCY LIGHTING (TENANT- N.I.C.) SHALL INCLUDE 90-MINUTE BATTERY BACK-UP FOR EXIT SIGNS. 50. ALL ROOF DRAINS SHALL BE LOCATED AT THE LOW POINT(S) OF THE ROOF, TAKING INTO CONSIDERATION THE CAMBER OF BEAMS AND DEFLECTION OF CANTILEVERS. THE CONTRACTOR SHALL VERIFY THAT POSITIVE DRAINAGE EXISTS FROM ALL POINTS ON THE ROOF PRIOR TO SHEATHING. 51. FIELD WELDING SHALL BE DONE BY WELDERS CERTIFIED BY THE CITY OF ARCADIA BUILDING DEPARTMENT FOR STRUCTURAL STEEL, REINFORCING STEEL, OR LIGHT GAGE STEEL FRAMING. CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR ALL STRUCTURAL FIELD WELDING. SHOP WELDING SHALL BE PERFORMED BY A CITY OF ARCADIA LICENSED FABRICATOR. 52. PROVIDE ISOLATION OF DISSIMILAR METALS (ALUMINUM, COPPER, STEEL, ETC.) FROM EACH OTHER (PROTECTION FROM GALVANIC CORROSION). 53. THE BUILDING SHALL BE PROVIDED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM PER NFPA 13. -or- THE EXISTING BUILDING AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE MODIFIED PER NFPA 13. SUBMIT PLANS TO THE CITY OF ARCADIA FIRE PREVENTION BUREAU AND THE OWNER'S FIRE INSURANCE RATING SERVICE FOR APPROVAL, AND TO THE ARCHITECT FOR REVIEW. THE CONTRACTOR SHALL PROVIDE A COMPLETE SYSTEM (DESIGN/BUILD, SEPARATE PERMIT), FROM CONNECTION TO THE SITE WATER MAIN (OR FIRE SERVICE VAULT OR FIRE LINE, WHERE PROVIDED) TO THE BUILDING SPRINKLER DISTRIBUTION. THE SYSTEM MUST BE FULLY OPERATIONAL AND ENERGIZED PRIOR TO FIXTURIZATION OF THE BUILDING. ALL HEADS SHALL BE SEMI-RECESSED AT CEILINGS, WITH SEISMIC EXTENDER RINGS TYP., U.N.O. 54. FIRE SPRINKLER SYSTEM MONITORING SHALL BE PROVIDED. ALARM, SUPERVISORY, AND TROUBLE SIGNALS SHALL BE DISTINCTLY DIFFERENT, AND SHALL BE AUTOMATICALLY TRANSMITTED TO AN APPROVED SUPERVISING STATION (OR WHEN APPROVED, SHALL SOUND AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION) PER NFPA 72. ONE EXTERIOR AUDIBLE DEVICE (BELL) SHALL BE CONNECTED TO THE SYSTEM. IF A FIRE ALARM SYSTEM IS INSTALLED, ACTUATION OF THE AUTOMATIC SPRINKLER SYSTEM SHALL ACTUATE THE BUILDING FIRE ALARM SYSTEM. ANY MISCELLANEOUS SMOKE DETECTORS IN HVAC RETURN DUCTS, AT FIRE/SMOKE DAMPERS, AT MAGNETIC RELEASE DOOR CLOSERS, OR AT DELAYED EXIT DEVICES SHALL BE CONNECTED THROUGH A COMMON ANNUNCIATOR PANEL INTO A SINGLE, UNIFIED ALARM SYSTEM (DESIGN/BUILD, SEPARATE PERMIT). PROVIDE SPACE FOR CONNECTION OF ADDITIONAL DETECTORS FROM (FUTURE) TENANT EQUIPMENT (N.I.C.). 55.IN ‘A’ OCCUPANCIES EXCEEDING 300 OCCUPANTS, OR IN ‘B’ OR ‘M’ OCCUPANCIES EXCEEDING 500 OCCUPANTS TOTAL OR 100 ABOVE OR BELOW THE THE LOWEST LEVEL OF EXIT DISCHARGE, PROVIDE A COMPLETE FIRE ALARM SYSTEM THROUGHOUT THE BUILDING PER NFPA 72 (INCLUDING ANNUNCIATOR PANEL, MANUAL PULL STATIONS, AND AUDIBLE/VISIBLE ALARMS). THE ALARM SHALL SEND A SIGNAL TO A CONSTANTLY ATTENDED LOCATION (MONITORING). THE SYSTEM SHALL BE INTERCONNECTED WITH SMOKE OR HEAT SENSORS IN RETURN DUCTS, ELEVATORS SHAFTS OR LOBBIES, FIRE/SMOKE DAMPERS, MAGNETIC HOLD-OPEN OR DELAYED EGRESS DEVICES, ETC., IN SHELL PROJECTS. PROVIDE ADEQUATE SPACE IN THE ANNUNCIATOR PANEL FOR FUTURE TENANT WORK. SUBMIT DESIGN/BUILD DRAWINGS TO THE CITY OF ARCADIA FIRE DEPARTMENT FOR APPROVAL, TO THE CLIENT'S FIRE INSURANCE RATING BUREAU, AND TO THE ARCHITECT FOR REVIEW. 56. CONTRACTOR SHALL PROVIDE A "KNOX" LOCK BOX PRIOR TO FINAL CONSTRUCTION APPROVAL (CONTACT FIRE MARSHALL FOR INFORMATION). PROVIDE NFPA 704 PLACARDS FOR HAZARDOUS MATERIALS AS DIRECTED BY THE FIRE INSPECTOR. 57. ALL BUILDING ENTRANCES SHALL BE ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES, AND SHALL BE IDENTIFIED WITH A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY, WITH ADDITIONAL DIRECTIONAL SIGNAGE AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN ACCESSIBLE ROUTE, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUIVALENT TO COLOR NO. 15090 IN FEDERAL STANDARD 599b. 58. THE SLOPE OF NEW WALKWAYS SHALL NOT EXCEED 1:20 (5%) EXCEPT WHERE RAMPS ARE NOTED. WALK CROSSLOPES SHALL NOT EXCEED 1:50 (2%) MAXIMUM TYPICAL. PROVIDE A LEVEL LANDING (DEFINED AS 2% MAXIMUM IN ANY DIRECTION) EXTENDING 5'-0" IN FRONT OF ALL DOORS. 59. PATCH AND REPAIR ANY HARDSCAPE DAMAGED DURING CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE THE WORK TO MAKE THE HARDSCAPE AS UNIFORM AND CONSISTENT AS POSSIBLE WITH EXISTING SITE HARDSCAPE. 60. ELECTRICAL CONVENIENCE OR COMMUNICATION SYSTEM RECEPTACLE OUTLETS SHALL BE LOCATED NO MORE THAN 48" FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15" FROM THE BOTTOM OF THE OUTLET BOX TO THE FINISHED FLOOR. ELECTRICAL CONTROLS AND SWITCHES SHALL BE LOCATED NO MORE THAN 48" FROM THE TOP OF THE OUTLET BOX TO THE FINISHED FLOOR. GENERAL NOTES VICINITY MAP DEFERRED SUBMITTALS SHEET INDEX @ At CL Centerline 'L' Angle Ø Diameter or Round % Percent # Pounds or Number (E) Existing (N) New A.B. Anchor Bolt A/C Air Condition A.C. Asphaltic Concrete ACOUST. Acoustic(al) ADJ. Adjacent A.F.F. Above Finish Floor ALUM. Aluminum APPROX. Approximate(ly) ARCH. Architect(ural) A.S.R. Automatic Sprinkler Riser AUTO. Automatic BD. Board BITUM. Bituminous BLDG. Building BLK. Block BLK'G Blocking BM. Beam BOT. Bottom CAB. Cabinet C.B. Catch Basin CEM. Cement CER. Ceramic C.I.P. Cast Iron Pipe C.J. Control Joint CL'G Ceiling CLR. Clear COL. Column CONC. Concrete CONT. Continuous CONN. Connect or Connection CTR. Center CTRSK. Countersink DBL. Double D.F. Douglas Fir or Drinking Fountain DET. Detail DIA. Diameter DIM. Dimension DN. Down DR. Door D.S. Downspout DW'G Drawing EA. Each E.J. Expansion Joint ELECT. Electrical ELEV. Elevation EMER. Emergency ENCL. Enclosure EQ. Equivalent EQPT. Equipment E.W.C. Electric Water Cooler EXST. Existing EXP. Expansion EXT. Exterior F.D. Floor Drain F.D.C. Fire Department Connection F.E. Fire Extinguisher F.E.C. Fire Extinguisher Cabinet F.H. Fire Hydrant or Flat Head F.H.C. Fire Hose Cabinet FIN. Finish F.F Finish Floor FLASH'G Flashing FLUOR. Fluorescent F.D. Floor Drain F.O.C. Face of Concrete F.O.F. Face of Finish F.O.FRAM'G Face of Framing F.O.M. Face of Masonry F.O.W. Face of Wall F.O.S. Face of Stud F.S. Floor Sink or Finish Surface FT. Foot or Feet FT'G Footing FURR'G Furring GA. Gauge GALV. Galvanized G.S. Galvanized Steel GYP. Gypsum H.B. Hose Bibb H.C. Hollow Core HD.,HDR, Head, Header HRDWD. Hardwood HDWR. Hardware H.M. Hollow Metal HORIZ. Horizontal HR. Hour HG.,HGT. High, Height INSUL. Insulation INT. Interior I.D. Inside Diameter JT. Joint JAN. Janitor LAB. Laboratory LAM. Laminate LAV. Lavatory LG., LGT. Long, Length MAX. Maximum M.B. Machine Bolt M.D.F. Medium Density Fiberboard MECH. Mechanical MEMB. Membrane MET. Metal MFR. Manufacturer MIN. Minimum MISC. Miscellaneous M.O. Masonry Opening M/R Moisture Resistant MT'D Mounted MTL. Metal N.I.C. Not in Contract NO. or # Number NOM. Nominal N.T.S. Not to Scale O.F.D. OverFlow Drain O.C. On Center O.D. Outside Diameter OFF. Office OPN'G Opening OPP. Opposite P-LAM. Plastic Laminate P.I.V. Post Indicator Valve PL Property Line PLAS. Plaster PLUMB. Plumbing PLYWD. Plywood P.M. Pressed Metal PR. Pair R. Riser RAD. Radius R.D. Roof Drain RDWD. Redwood REF. Reference REFRIG. Refrigerator REINF. Reinforced REQ'D Required R.H. Round Head RM. Room R.O. Rough Opening S.C. Solid Core SCHED. Schedule SECT. Section S.F. Square Feet SHT. Sheet SIM. Similar SLD'G Sliding SP. Space SPEC. Specification (Project Manual) SQ. Square S.S. Stainless Steel or Sanitary Sewer STA. Station STD. Standard STL. Steel STOR.A. Storage STRUCT. Structural SUSP. Suspended SYM. Symmetrical S.D. Storm Drain T. Tread TEL. Telephone TANDG. Tongue AND Groove THK.,THKN. Thick, Thickness T.O.C. Top of Curb T.O.M. Top of Masonry T.O.P. Top of Parapet T.O.S. Top of Sheathing T.O.W. Top of Wall TYP. Typical U.N.O. Unless Noted Otherwise VERT. Vertical W/ With WD. Wood W.M. Water Meter WTRPRF. Waterproof MARKETING OFFICE TENANT IMPROVEMENTS A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 ARCHITECTURAL T101 TITLE SHEET CG01 CALGREEN 2023 D010 DEMOLITION NOTES D011 DEMOLITION FLOOR PLAN & CEILING PLAN A010 OVERALL MALL LEASE PLAN (FOR REFERENCE ONLY) A101 FLOOR PLAN & REFLECTED CEILING PLAN A102 EXISTING ROOF PLAN A201 STOREFRONT & INTERIOR ELEVATIONS & SECTIONS A202 MILLWORK DETAILS (DELETED SHEET) A203 PAINT SPECIFICATION A301 WALL SECTIONS AND INTERIOR PARTITION DETAILS A401 ENLARGED TOILET PLAN, ELEVATIONS & CEILING DETAILS A601 DOOR SCHEDULE, NOTES AND DETAILS MECHANICAL M-1 .0 MECHANICAL SCHEDULES NOTES & DETAILS M-2.0 MECHANICAL FLOOR PLAN M-3.0 MECHANICAL TITLE 24 M-3.1 MECHANICAL TITLE 24 PLUMBING P-1.0 PLUMBING SCHEDULES, NOTES, & DETAILS P-2.0 PLUMBING PLAN ELECTRICAL E-1.0 SYMBOL LIST & GENERAL NOTES E-2.0 ELECTRICAL PLAN E-3.0 PARTIAL SINGLE LINE DIAGRAM & PANEL SCHEDULE E-5.0 ELECTRICAL SPECIFICATIONS E: patricia@shopsatsantaanita.com OWNER RIDERWOOD USA INC. 400 S. BALDWIN AVENUE, SUITE 231 ARCADIA, CALIFORNIA 91007 T: 626.462.8504 C: 626.632.0781 CONTACT: PATRICIAAPEL, CPM, CLS E: hrojas@mmaarchitecture.com ARCHITECT MMA ARCHITECTURE 120 WEST LIME AVENUE MONROVIA, CALIFORNIA, 91016 T: 626.583.8348 D: 626.340.0525 CONTACT: HILDA ROJAS THE FOLLOWING ITEMS SHALL BE PROVIDED ON A DESIGN/BUILD BASIS, UNDER SEPARATE PERMITS OBTAINED BY THE RESPECTIVE SUB-CONTRACTORS: ·TENANT SIGNAGE ·FIRE SPRINKLER AND FIRE ALARM MODIFICATION ·FRAMELESS ENTRY DOOR/STOREFRONT WALL TYPE SYMBOLS KEYNOTE SYMBOLS DOOR NUMBER WINDOW NUMBER CEILING HEIGHT START POINT ROOF ELEVATION ELEVATION HEIGHT MARK FINISH MATERIAL COLOR COLUMN GRID LINES ELEVATION NUMBER ELEVATION SHEET INTERIOR ELEVATION NUMBER INTERIOR ELEVATION SHEET DETAIL NUMBER DETAIL SHEET PLAN VIEW SECTION VIEW SECTION NUMBER SECTION SHEET REVISION CLOUD AND DELTA MATCH LINE 1 A B 102 201 9'-0" 20'-0 " T.O.S T.O.P 20'-0" B 2 01 01 A201 1 2 3 4 1 A203 - A301 A A503 3 ZONING ADDRESS:........................................................ 400 S. BALDWIN AVENUE ARCADIA, CA 91007 PROPOSED USE:............................................ OFFICE EXISTING ZONING:......................................... RETAIL JURISDICTION: .............................................. CITY OF ARCADIA BUILDING DATA EXISTING RETAIL: ....................................... +/- 1,095 S.F. CONSTRUCTION TYPE: ................................ IIA, FIRE SPRINKLERED OCCUPANCY GROUP: .................................. B - OCCUPANCY B A APPLICABLE CODES 2022 CALIFORNIA BUILDING CODE (CBC). 2022 CALIFORNIA ELECTRICAL CODE (CEC). 2022 CALIFORNIA MECHANICAL CODE (CMC). 2022 CALIFORNIA PLUMBING CODE (CPC). 2022 CALIFORNIA ENERGY CODE (CEnC) 2022 CALIFORNIA GREEN BUILDING CODE. 2022 CALIFORNIA FIRE CODE (CFC) SCOPE OF WORK TENANT IMPROVEMENTS FOR FUTURE MARKETING OFFICE IN VACANT SPACE INSIDE MALL : - CHANGE OF OCCUPANCY FROM M TO B - DEMOLITION OF EXISTING INTERIOR FLOORING, CEILING AND FINISHES - MINOR FACADE IMPROVEMNENTS OF SPACE - NEW MANAGER'S OFFICE IN OLD DRESSING ROOM - NEW CONFERENCE ROOM - NEW WAITING AREA - NEW OPEN DESK AREA - NEW BREAKROOM/LOUNGE AREA - (E) RESTROOM TO BE RELOCATED AND NEW OFFICE ADDED - (E) CEILING GRID TO REMAIN REPLACE LIGHTS - NEW CEILING GRID AND LIGHTS AROUND BREAKROOM AND CONFERENCE ROOM - (E) HVAC UNIT TO REMAIN, RE-ROUTE ALL DISTRIBUTION PER NEW LAYOUT - (E) ELETRICAL PANEL AND SUB METER TO REMAIN 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA NSITE 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 E: dsor@empire3.net MECHANICAL ENGINEER EMPIRE 3 CONSULTING ENGINEERS, INC 3711 LONG BEACH BLVD. SUITE 5058 LONG BEACH, CALIFORNIA 90807 T: 562.206.1964 F: CONTACT: DAVID SOR E: tmock@empire3.net PLUMBING ENGINEER EMPIRE 3 CONSULTING ENGINEERS, INC 3711 LONG BEACH BLVD. SUITE 5058 LONG BEACH, CALIFORNIA 90807 D: 562.206.1964 T: 562.222.4700 CONTACT: TRAVUTH MOCK vmock@empire3.net ELECTRICAL ENGINEER EMPIRE 3 CONSULTING ENGINEERS, INC 3711 LONG BEACH BLVD. SUITE 5058 LONG BEACH, CALIFORNIA 90807 T: 562.206.1964 F: CONTACT: VISETH MOCK PLUMBING FIXTURE ANALYSIS OCCUPANCY LOAD DATA PER CBC/CPC 2022 CH. 4, TABLE 422.1 AND TABLE 4-1 MALE WC LAVATORY FEMALE MALE FEMALE REQUIRED URINAL MALE PROVIDED (1) ALL GENDER RESTROOM WITH 1 WC AND 1 LAV 1109.2.1.2 Unisex Toilet Rooms Unisex toilet rooms shall include only one water closet and only one lavatory. A unisex bathing room in accordance with 1109.2.1.3 shall be considered a unisex toilet room. Exception: A urinal is permitted to be provided in addition to the water closet in a unisex toilet room. 1: 1-50 1: 1-75 1: 1-50 1: 1-100 1 UNISEX RESTROOM PERMITTED PER 422.2 EXCEPTION (2) REQUIRED PLUMBING FIXTURES PER CPC TABLE 422.1 1: 1-15 PROVIDED 1 1 1 11 1 1 1 -1 MALE FEMALE 15 15 OCCUPANT LOAD PER GENDER 4 OCCUPANT LOAD & EXIT REQUIREMENTS PER 1006.3.1 & 1005.3.2 FUTURE MARKETING OFFICE 1,095 SF / 150 = 8 OCC TOTAL EXIT WIDTH REQUIRED: 8 OCC. X 0.20 = 1.6" TOTAL EXIT WIDTH PROVIDED: 6' x 12 = 72" PC1 PC1 PC1 PC3 PC3 R1 R1 R1 R1 R2 OCCUPANCY LOAD DATA PER CBC/CPC 2022 CH. 4, TABLE 422.1 AND TABLE 4-1 SPACE OCCUPANT LOAD LOAD FACTOR AREA ± SF 1/150 ACCESSORY RESTROOMS, COPY RM, CLOSET, STORAGE MANAGER'S OFFICE ± 53 S.F. ± 197 S.F. TOTAL INTERIOR AREA ± 1,095 S.F.TOTAL OCC. LOAD 30 /15LOBBY AREA ± 141 S.F.10 /15CONFERENCE ROOM ± 219 S.F.15 /150OPEN OFFICE ± 315 S.F.2 /150BREAKROOM± 115 S.F.1 - PC1 R1 1/150OFFICE ± 55 S.F. R2 R2 6.26.25 MERV 13 FILTERS PART OF MECH. DESIGN CG 01 CALGREEN 2022 2022 CALGREEN NON-RESIDENTIAL MANDATORY MEASURE CHECKLIST SITE DEVELOPMENT IF THE PROJECT IS ANTICIPATED TO GENERATE VISITOR TRAFFIC, PROVIDE PERMANENTLY ANCHORED BICYCLE RACKS WITHIN200 FEET OF THE VISITORS' ENTRANCE, READILY VISIBLE TO PASSERS-BY, FOR 5% OF VISITOR MOTORIZED VEHICLE PARKING CAPACITY, WITH A MINIMUM OF ONE TWO-BIKE CAPACITY RACK. SHORT-TERM BICYCLE PARKING 5.106.4.1.1 INSTALL SHORT TERM BIKE RACKS N/A LONG-TERM BICYCLE PARKING 5.106.4.1.2 INSTALL LONG TERM BIKE LOCKERS LIGHT POLLUTION REDUCTION 5.106.8 INCLUDED IN ELECT. DESIGN METERS5.303.1 SEE CIVIL DW'GS. NEW BUILDING OR ADDITIONS IN EXCESS OF 50,000 SF 5.303.1.1 SEPARATE METERS FOR EACH TENANT WATER CONSERVING FIXTURES 5.303.3 PLUMBING FIXTURES SHALL BE IN COMPLIANCE WITH FLOW RATES SEE PLUMB. DW'GS OUTDOOR WATER USE5.304 OUTDOOR WATER USE PER MODEL WATER EFFICIENCY LANDSCAPE ORDINANCE (MWELO), FOR NEW LANDSCAPE AREAS OVER 500 SF, OR REHABILITATED AREAS GREATER THAN 2,500 SF. WEATHER PROTECTION5.407.1 PROVIDE A WEATHER-RESISTANT EXTERIOR WALL AND FOUNDATION ENVELOPE AS REQUIRED BY CALIFORNIA BUILDING CODE SECTION 1402.2, MANUFACTURER'S INSTALLATION INSTRUCTIONS, OR LOCAL ORDINANCE, WHICHEVER IS MORE STRINGENT. MOISTURE CONTROL5.407.2 ACTION TAKENREQUIREMENTSCODE SECTION SEE DRAWINGDESCRIPTION WATER EFFICIENCY AND CONSERVATION - INDOOR WATER USE ACTION TAKENREQUIREMENTSCODE SECTION SEE DRAWINGDESCRIPTION WATER EFFICIENCY AND CONSERVATION - OUTDOOR WATER USE ACTION TAKENREQUIREMENTSCODE SECTION SEE DRAWINGDESCRIPTION WEATHER RESISTANCE AND MOISTURE MANAGEMENT ACTION TAKENREQUIREMENTSCODE SECTION SEE DRAWINGDESCRIPTION CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING ACTION TAKENREQUIREMENTSCODE SECTION SEE DRAWINGDESCRIPTION ENVIRONMENTAL QUALITY - POLLUTANT CONTROL ACTION TAKENREQUIREMENTSCODE SECTION SEE DRAWINGDESCRIPTION CONSTRUCTION WASTE MANAGEMENT 5.408.1 CONTRACTOR WILL HAVE THE OPTION OF USING PRE-CERTIFIED LANDFILLS OR PREPARING A WASTE MANAGEMENT PLAN. IF NOT, WASTE MANAGEMENT PLAN SHALL BE APPROVED PRIOR TO REMOVAL OF ANY CONSTRUCTION WASTE. N/A N/A N/A N/A N/A SEE ARCH. ELEVATIONS AND WALLS SECTIONS. SEE LANDSC./IRRIG. SEE ARCH. PLANS. BY CONTRACTOR LANDSCAPE WATER BUDGET, DROUGHT TOLERANT PLANTS, AND IRRIGATION CONTROLS. EXTERIOR WEATHER BARRIERS SPRINKLERS DIRECTED AWAY FROM BLDG'S. ENTRIES COVERED BY 4'-0" MIN. OVERHANGS. NON-ABSORBENT FLOOR 2'-0 AROUND AND PERPENDICULAR TO OPENINGS. EMPLOY MOISTURE CONTROL MEASURES BY THE FOLLOWING METHODS: 1. PREVENT IRRIGATION SPRAY ON STRUCTURES. 2. DESIGN EXTERIOR ENTRIES AND OPENINGS TO PREVENT WATER INTRUSION INTO BUILDINGS. FOR BUILDINGS WITH OVER 10 TENANT-OCCUPANTS, PROVIDE SECURE BICYCLE PARKING FOR 5% OF TENANT-OCCUPIED MOTORIZED VEHICLE. PARKING CAPACITY, WITH A MINIMUM OF ONE SPACE. OUTDOOR LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED TO COMPLY WITH THE FOLLOWING: 1. THE MINIMUM REQUIREMENTS IN THE CALIF. ENERGY CODE (CEC) FOR LIGHTING IN ZONES 0-4; AND 2. BACKLIGHT (B) RATINGS AS DEFINED IN IES TM-15-11; UPLIGHT AND GLARE AS DEFINED IN THE CALIF. ENERGY CODE; AND 3. ALLOWABLE BUG RATINGS NOT EXCEEDING THOSE SHOWN IN TABLE 5.106.8 [N], OR LOCAL CODE, WHICHEVER IS MORE STRINGENT. SEPARATE METERS SHALL BE INSTALLED FOR THE USES DESCRIBED IN SECTIONS 5.303.1. AND 503.1.2 FOR BUILDINGS IN EXCESS OF 50,000 SF, SEPARATE METERS SHALL BE INSTALLED AS FOLLOWS: 1. FOR EACH INDIVIDUAL LEASED, RENTED OR OTHER TENANT SPACE WITHIN THE BUILDING PROJECTED TO CONSUME MORE THAN 100 GAL./DAY (380L/DAY), INCLUDING, BUT NOT LIMITED TO SPACES USED FOR LAUNDRY OR CLEANERS, RESTAURANT OR FOOD SERVICE, MEDICAL OR DENTAL OFFICE, LABORATORY, OR BEAUTY SALON OR BARBER SHOP. TOILET 1.28 GAL. PER FLUSH MAX., WALL MOUNTED URINAL 1.25 GAL. PER FLUSH MAX., LAVATORY FAUCETS O.5 GPM FLOW MAX., METERING FAUCETS 0.20 GAL. PER CYCLE MAX. THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE 52.2-1999, AND AN AVERAGE EFFICIENCY OF 30% BASED ON ASHRAE 52.1-1992. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY. TEMPORARY VENTILATION 5.504.1. COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION 5.504.3 CONTRACTOR SHALL PROTECT HVAC EQUIPMENT AND COMPONENTS FROM DUST AND DEBRIS AS DESCRIBED. SEE MECH. DW'GSAT THE TIME OF ROUGH INSTALLATION, OR DURING STORAGE, ON THE CONSTRUCTION SITE AND UNTIL FINAL START UP IF THE HEATING AND COOLING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL TO REDUCE THE AMOUNT OF DUST AND DEBRIS WHICH MAY COLLECT IN THE SYSTEM. FINISH MATERIAL POLLUTANT CONTROL 5.504.4 CONTRACTOR TO PROVIDE DETAILED DOCUMENTATION INCLUDE A COPY OF ALL INSPECTION VERIFICATIONS AND REPORTS REQUIRED BY THE ENFORCING AGENCY. ADHESIVE SEALANTS, CAULKS 5.504.4.1 CONTRACTOR SHALL USE PRODUCTS IN ACCORDANCE WITH TABLES 5.504.4.1 AND 5.504.4.2. ADHESIVES AND SEALANTS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS IDENTIFIED IN SECTION 5.504.4.1., AND TABLES 5.504.4.1 AND 5.504.4.2. SEE TABLES BELOW PAINTS AND COATINGS 5.504.4.3.CONTRACTOR SHALL USE PRODUCTS IN ACCORDANCE WITH TABLES 5.504.4.1 AND 5.504.4.2. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE 5.504.4.3 UNLESS MORE STRINGENT LOCAL LIMITS APPLY. SEE TABLE BELOW AEROSOL PAINTS AND COATINGS 5.504.4.3.1 AEROSOL PAINTS AND COATINGS SHALL MEET THE PRODUCT-WEIGHTED MIR LIMITS FOR ROC INSPECTION 94522(a)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES (CCR, TITLE 17, SECTION 94520 ET SEQ.) CONTRACTOR SHALL USE PRODUCTS IN ACCORDANCE WITH THE REQUIREMENTS DESCRIBED. VERIFICATION5.504.4.3.2 VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE REQUEST OF THE ENFORCING AGENCY. CONTRACTOR SHALL PROVIDE VERIFICATION OF COMPLIANCE, IF REQUESTED. CARPET SYSTEMS5.504.4.4 ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE STANDARDS LISTED IN 5.504.4.4 NO CARPET USED ON THIS PROJECT CARPET CUSHION5.504.4.4.1 ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL NO CARPET USED ON THIS PROJECT CARPET ADHESIVE5.504.4.4.2 ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 5.504.4.1. NO CARPET USED ON THIS PROJECT COMPOSITE WOOD PRODUCTS 5.504.4.5 HARDWOOD PLYWOOD, PARTICLE BOARD, AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR E.XTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN TABLE 5.504.4 CONTRACTOR SHALL USE PRODUCTS IN ACCORDANCE WITH TABLE 5.504.4. DOCUMENTATION5.504.4.5.3 VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL INCLUDE AT LEAST ONE OF THE FOLLOWING: 1. PRODUCT CERTIFICATIONS AND SPECIFICATIONS. 2. CHAIN OF CUSTODY CERTIFICATIONS. 3. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY. CONTRACTOR SHALL PROVIDE VERIFICATION OF COMPLIANCE AS REQUESTED. SEE TABLE BELOW RESILIENT FLOORING SYSTEMS 5.504.4.6 FOR 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING, INSTALLED RESILIENT FLOORING SHALL MEET AT LEAST ONE OF THE REQUIREMENTS OF SECTION 5.504.4.6. NO RESILIENT FLOORING USED ON THIS PROJECT. VERIFICATIONS OF COMPLIANCE 5.504.4.6.1 DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT RESILIENT FLOORING MATERIALS MEET THE POLLUTANT EMISSION LIMITS. NO RESILIENT FLOORING USED ON THIS PROJECT. FILTERS5.504.5.3 IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY THAT PROVIDES AT LEAST A MERV OF 13, INSTALLED PRIOR TO OCCUPANCY. SEE MECH. DW'GS ENVIRONMENTAL TOBACCO SMOKE CONTROL 5.504.7 WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES AND OPERABLE WINDOWS WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR REGULATIONS. CONTRACTOR SHALL INSTALL SIGNAGE INSTALLATION OF HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL COMPLY WITH SECTIONS 5.508.1.1 AND 5.508.1.2. OZONE DEPLETION AND GREENHOUSE GAS REDUCTION 5.508.1 NO HALONS OR CFC'S USED ON PROJECT ENVIRONMENTAL TOBACCO SMOKE CONTROL 5.504.7 WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES AND OPERABLE WINDOWS WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR REGULATIONS. CONTRACTOR SHALL INSTALL SIGNAGE N/A BY CONTRACTOR SEE TABLES BELOW BY CONTRACTOR N/A N/A N/A BY CONTRACTOR N/A N/A THE PERMANENT HVAC SYSTEM WILL NOT BE USED DURING CONSTRUCTION A MINIMUM OF 65% OF THE CONSTRUCTION WASTE GENERATED AT THE SITE IS DIVERTED TO RECYCLE OR SALVAGE. THIS IS ACHIEVED EITHER BY USING CITY PRE-CERTIFIED LANDFILLS OR IMPLEMENTATION OF A WASTE MANAGEMENT PLAN. WASTE MANAGEMENT PLAN SHALL BE PRE-APPROVED BY ENVIRONMENTAL SERVICES DEPARTMENT. PRESCRIPTIVE METHOD5.507.4.1 WALL AND ROOF/CEILING ASSEMBLIES MAKING UP THE BUILDING ENVELOPE SHALL MEET A COMPOSITE STC OF AT LEAST 50 OR COMPOSITE OITC RATING OF NO LESS THAN 40 AND EXTERIOR WINDOWS SHALL HAVE A MINIMUM STC OF 40 OR OITC OF 30 FOR ANY OF THE FOLLOWING LOCATIONS: 1. WITHIN THE 65 CNEL NOISE CONTOUR OF AN AIRPORT. 2. WITHIN THE 65 CNEL NOISE CONTOUR OF A FREEWAY. PERFORMANCE METHOD 5.507.4.2 FOR BUILDINGS LOCATED AS DEFINED IN SECTION 5.507.4.1 OR 5.507.4.1.1, WALL AND ROOF CEILING ASSEMBLIES EXPOSED TO NOISE SOURCE MAKING UP THE BUILDING SHALL BE OR ADDITION OR ALTERED ENVELOPE SHALL BE CONSTRUCTED TO PROVIDE AN INTERIOR NOISE ENVIRONMENT ATTRIBUTABLE TO EXTERIOR SOURCES THAT DOES NOT EXCEED AN Leq-1 HR OF 50 dBA IN OCCUPIED AREAS. SEE SECTION 5.507.4.2 FOR SITE FEATURES AND SECTION 5.507.4.2.2 FOR DOCUMENTATION OF COMPLIANCE. INTERIOR SOUND5.507.4.3 INTERIOR WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING TENANT SPACES AND PUBLIC SPACES SHALL HAVE AN STC OF AT LEAST 40. BUILDING MAINTENANCE AND OPERATION ACTION TAKENREQUIREMENTSCODE SECTION SEE DRAWINGDESCRIPTION 5.410.1 COMMISSIONING5.410.2 BUILDING IS LESS THAN 10,000 SF. OWNER'S PROJECT REQUIREMENT (OPR) 5.410.2.1 BUILDING IS LESS THAN 10,000 SF. BASIS OF DESIGN (BOD) 5.410.2.2 BUILDING IS LESS THAN 10,000 SF. 5.410.2.3 BUILDING IS LESS THAN 10,000 SF. FUNCTIONAL PERFORMANCE TESTING 5.410.2.4 DOCUMENTATION AND TRAINING 5.410.2.5 SYSTEM MANUAL5.410.2.5.1 SYSTEM OPERATIONS TRAINING 5.410.2.5.2 COMMISIONING REPORT 5.410.2.6 BUILDING IS LESS THAN 10,000 SF. TESTING AND ADJUSTING 5.410.4 HVAC UNITS ONLY, NO DUCTWORK SYSTEMS5.410.4.2 CONTRACTOR SHALL TEST ALL APPLICABLE SYSTEMS PROCEDURES5.410.4.3 CONTRACTOR SHALL PERFORM TESTING AND ADJUSTING. HVAC BALANCING5.410.4.3.1 HVAC UNITS ONLY, NO DUCTWORK REPORTING5.410.4.4 CONTRACTOR TO PROVIDE FINAL REPORT TO ARCHITECT AND OWNER. OPERATIONAL AND MAINTENANCE MANUAL 5.410.4.5 CONTRACTOR TO PROVIDE OWNER WITH DOCUMENTATION AS PART OF PROJECT CLOSE-OUT. INSPECTION AND REPORTS 5.410.4.5.1 PART OF TRASH ENCLOSURE AREAS SEE ARCH. SITE PLAN N/A N/A N/A N/A N/A BY CONTRACTOR BY CONTRACTOR BY CONTRACTOR N/A START TEST UNITS ONLY, FUTURE WORK N.I.C. (BY TENANT) BY CONTRACTOR BY CONTRACTOR START TEST UNITS ONLY, FUTURE WORK N.I.C. (BY TENANT) BY CONTRACTOR BY CONTRACTOR BY CONTRACTOR BUILDING IS LESS THAN 10,000 SF. CONTRACTOR SHALL PROVIDE OWNER WITH MANUALS AND EXPLANATION OF SYSTEM OPERATIONS. CONTRACTOR SHALL PROVIDE OWNER WITH MANUALS AND EXPLANATION OF SYSTEM OPERATIONS. CONTRACTOR SHALL PROVIDE OWNER WITH MANUALS AND EXPLANATION OF SYSTEM OPERATIONS. CONTRACTOR TO PROVIDE OWNER WITH DOCUMENTATION AS PART OF PROJECT CLOSE-OUT. RECYCLING BY OCCUPANTS BASIS OF DESIGN (BOD) PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE DEPOSITING, STORAGE,AND COLLECTION OF NON-HAZARDOUS MATERIALS FOR RECYCLING. FOR NEW BUILDINGS 10,000 SF AND OVER, BUILDING COMMISSIONING FOR ALL BUILDING SYSTEMS IS COVERED BY T-24, PART 6, PROCESS SYSTEMS, AND RENEWABLE ENERGY SYSTEMS SHALL BE INCLUDED IN THE DESIGN AND CONSTRUCTION PROCESS OF THE BUILDING PROJECT. COMMISSIONING REQUIREMENTS SHALL INCLUDE ITEMS LISTED IN SECTION 5.410.2. DOCUMENTED BEFORE THE DESIGN PHASE OF THE PROJECT BEGINS THE OPR SHALL INCLUDE ITEMS LISTED IN SECTION 5.410.4. A WRITTEN EXPLANATION OF HOW THE DESIGN OF THE BUILDING SYSTEMS MEETS THE OPR SHALL BE COMPLETED AT THE DESIGN PHASE OF THE BUILDING PROJECT AND UPDATED PERIODICALLY TO COVER THESYSTEMS LISTED IN SECTION 5.410.2.2. A COMMISSIONING PLAN DESCRIBING HOW THE PROJECT WILL BE COMMISSIONED SHALL BE STARTED DURING THE DESIGN PHASE OF THE BUILDING PROJECT AND SHALL INCLUDE ITEMS LISTED IN SECTION 5.410.2.3. SHALL DEMONSTRATE THE CORRECT INSTALLATION AND OPERATION OF EACH COMPONENT, SYSTEM, AND SYSTEM TO SYSTEM INTERFACE IN ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. A SYSTEMS MANUAL AND SYSTEMS OPERATIONS TRAINING ARE REQUIRED. THE SYSTEMS MANUAL SHALL BE DELIVERED TO THE BUILDING OWNER OR REPRESENTATIVE AND FACILITIES OPERATOR, AND SHALL INCLUDE THE ITEMS LISTED IN SECTION 5.410.2.5.1. THE TRAINING OF THE APPROPRIATE MAINTENANCE STAFF FOR EACH EQUIPMENT TYPE AND/OR SYSTEM SHALL INCLUDE ITEMS LISTED IN SECTION 5.410.2.5.2. A COMPLETE REPORT OF COMMISSIONING PROCESS ACTIVITIES UNDERTAKEN THROUGH THE DESIGN, CONSTRUCTION AND REPORTING RECOMMENDATI ONS FOR POST-CONSTRUCTION PHASES OF THE BUILDING PROJECT SHALL BE COMPLETED AND PROVIDED TO THE OWNER OR REPRESENTATIVE. TESTING AND ADJUSTING OF SYSTEMS SHALL BE REQUIRED FOR NEW BUILDINGS LESS THAN 10,000 SQUARE FEET, OR NEW SYSTEMS TO SERVE AND ADDITION OR ALTERATION. DEVELOP A WRITTEN PLAN OF PROCEDURES FOR TESTING AND ADJUSTING SYSTEMS. SYSTEMS TO BE INCLUDED FOR TESTING AND ADJUSTING SHALL INCLUDE, AS APPLICABLE TO THE PROJECT: 1. HVAC SYSTEMS AND CONTROLS 2. INDOOR AND OUTDOOR LIGHTING 3. WATER HEATING SYSTEMS 4. RENEWABLE ENRGY SYSTEMS 5. LANDSCAPE IRRIGATION SYSTEMS 6. WATER REUSE SYSTEMS PERFORM TESTING AND ADJUSTING PROCEDURES IN ACCORDANCE WITH INDUSTRY BEST PRACTICES AND APPLICABLE NATIONAL STANDARDS ON EACH SYSTEM. BEFORE A NEW SPACE-CONDITIONING SYSTEM SERVING A BUILDING OR SPACE IS OPERATED FOR NORMAL USE, THE SYSTEM SHOULD BE BALANCED IN ACCORDANCE WITH THE PROCEDURES DEFINED BY NATIONAL STANDARDS LISTED IN SECTION 5.410.4.3.1. AFTER COMPLETION OF TESTING, ADJUSTING AND BALANCING, PROVIDE A FINAL REPORT OF TESTING SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES. PROVIDE THE BUILDING OWNER WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTIES/WARRANTIES FOR EACH SYSTEM PRIOR TO FINAL INSPECTION INCLUDE A COPY OF ALL INSPECTION VERIFICATIONS AND REPORTS REQUIRED BY THE ENFORCING AGENCY. N/A N/A NOT WITHIN NOTED NOISE CONTOURS NOT EXPOSED TO NOISE SOURCES N/A VOC LIMIT TABLES - S A M P L E F O R M S T O B E F I L L E D O U T B Y C O N T R A C T O R - VER I F Y L O C A L R E Q U I R E M E N T S - S A M P L E F O R M S T O B E F I L L E D O U T B Y C O N T R A C T O R - VER I F Y L O C A L R E Q U I R E M E N T S - S A M P L E F O R M S T O B E F I L L E D O U T B Y C O N T R A C T O R - VER I F Y L O C A L R E Q U I R E M E N T S ELECTRIC VEHICLE CHARGING 5.106.5.3 PROVIDE MARKED STALLS AND RELATED ITEMS AS NOTED N/APROVIDE DESIGNATED PARKING FOR EV CAPABLE SPACES AND ELECTRIC VEHICLE CHARGING STATIONS (EVCS), INCLUDING CONDUIT STUBS, WIRING, AND CIRCUITING, AS SHOWN ON TABLE 5.106.5.3.1 DOCUMENTATION5.408.4 USE SAMPLE FORMS (BELOW), OR LOCAL AGENCY FORMS. BY CONTRACTORPROVIDE DOCUMENTION OF WASTE DIVERSION TO ENFORCING AGENCY SEE SHEET A301 COMMERCIAL REFRIGERATION SYSTEMS INSTALLED IN FOOD STORES OF 8,000 SF OR LARGER USING HIGH GLOBAL WARMING POTENTIAL (GWP) REFRIGERANTS OF 150 GWP OR GREATER. EXCEPTION: SYSTEMS CONTAINING REFRIGERANT LESS THAN 150 GWP ARE EXEMPT. SYSTEM SHALL COMPLY WITH MECH. CODE. SUPERMARKET REFRIGERANT LEAK REDUCTION 5.508.2 NO COMMERCIAL REFRIGERATION SYSTEMS N/A CONTRACTOR INSTALL DEMISING PARTITIONS AND FLOOR/CEILING ASSEMBLIES AS NOTED. NOISE CONTOURS NOT READILY AVAILABLE 5.507.4.1.1 BUILDINGS EXPOSED TO A NOISE LEVEL OF 65 dB Leq-1 HR DURING ANY HOUR OF OPERATION SHALL HAVE EXTERIOR WALL AND ROOF/CEILING ASSEMBLIES WITH STC RATING OF AT LEAST 45 (OR OITC 35), WITH EXTERIOR WINDOW OF A MINIMUM STC OF 40 (OITC 30). NOT EXPOSED TO NOTED NOISE LEVEL N/A N/A N/A A SEPARATE SUBMETER OR METERING DEVICE SHALL BE PROVIDED FOR ANY TENANT WITHIN A PROJECT OR SPACE WITHIN A BUILDING THAT IS PROJECTED TO CONSUME MORE THAN 1000 GAL./DAY. EXCESS CONSUMPTION 5.303.1.2 SHADE TREES5.106.12 LOCATED SHADE TREES N/ASHADE TREES SHALL BE PLANTED AS FOLLOWS: 1. MINIMUM #10 CONTAINERS INSTALLED TO PROVIDE SHADE OVER 50% OF THE PARKING AREA IN 15 YEARS. 2. MINIMUM #10 CONTAINERS INSTALLED TO PROVIDE SHADE OVER 20% OF LANDSCAPE AREAS IN 15 YEARS. 3. MINIMUM #10 CONTAINERS INSTALLED TO PROVIDE SHADE OVER 20% OF HARDSCAPE AREAS IN 15 YEARS. SEPARATE METERS OR SUB-METERS WHERE REQUIRED SEE PLUMB. DW'GS EV CHARGING: MEDIUM AND HEAVY DUTY 5.106.5.4 PROVIDE FUTURE LOCATIONS AND RELATED ITEMS AS NOTED N/APROVIDE CAPACITY FOR FUTURE EV TRUCK CHARGING STATIONS AT GROCERY AND RETAIL STORES, AND WAREHOUSES, INCLUDING PANEL CIRCUITS AND EMPTY CONDUIT STUBS, AS SHOWN ON TABLE 5.106.5.4.1 A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 6.26.25 TYPICAL DEMOLITION NOTES GENERAL DEMOLITION NOTES: 1. ALL WORK PERFORMED BY THE CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF MUNICIPAL, LOCAL OR FEDERAL AND STATE LAWS AS WELL AS ANY OTHER GOVERNING REQUIREMENTS, WHETHER OR NOT SPECIFIED ON THE DRAWINGS. 2. WHERE THE CONTRACT NOTES OR DRAWINGS CALL FOR ANY WORK OF A MORE STRINGENT NATURE THAN THAT REQUIRED BY THE BUILDING CODE OR ANY OTHER DEPARTMENT HAVING JURISDICTION OVER THE WORK, THE WORK OF THE MOST STRINGENT NATURE CALLED FOR BY THE CONTRACT, CONSTRUCTION NOTES, OR DRAWINGS SHALL BE FURNISHED IN ALL CASES. 3. THE GENERAL CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS FROM HIS OWN AND HIS SUBCONTRACTORS' WORK AND PROVIDE FOR ITS REMOVAL FROM THE JOBSITE. 4. THE CONTRACTOR SHALL EXERCISE STRICT DUST CONTAINMENT CONTROL TO PREVENT DIRT OR DUST FROM LEAVING THE J0BSITE. 5. THE CONTRACTOR SHALL PROVIDE PROTECTION DURING SITE WORK, DEMOLITION, AND CONSTRUCTION. 6. THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING CONSTRUCTION, STRUCTURE, OR EQUIPMENT SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER, AT THE EXPENSE OF THE CONTRACTOR. 7. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION FOR HIS WORK UNTIL COMPLETION OF CONTRACTED WORK. 8. THESE DRAWINGS, NOTES, AND SCHEDULES CONVEY THE DESIGN INTENT. THE HIGHEST POSSIBLE QUALITY OF WORKMANSHIP, MATERIAL, AND EQUIPMENT SHALL BE USED. THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON SITE DURING ALL CONSTRUCTION PHASES FOR THE USE OF ALL TRADES. 9. THE CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE SETS OF CONSTRUCTION DRAWINGS, OR ASSUME FULL RESPONSIBILITY FOR COORDINATION OF WORK WHEN COMPLETE SETS ARE NOT AVAILABLE TO SUBCONTRACTORS. 10. ALL REQUIRED EXITS, WAYS OF APPROACH THERETO, AND WAYS OF TRAVEL FROM THE EXIT INTO THE STREET SHALL CONTINUOUSLY BE MAINTAINED FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS FOR EGRESS IN CASE OF FIRE OR OTHER EMERGENCY. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION. 11. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LEGALLY REQUIRED APPROVALS AND PERMITS NECESSARY FOR THE EXECUTION AND COMPLETION OF HIS WORK. FORWARD COPIES OF EXECUTED PERMITS TO ARCHITECT. 12. THE CONTRACTOR IS WHOLLY RESPONSIBLE FOR THE COORDINATION AND SCHEDULING OF THE WORK FOR ALL SUBCONTRACTORS, CRAFTSMEN, AND TRADESMEN REQUIRED TO COMPLETE THE JOB. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF HE CANNOT COMPLY WITH ALL REQUIREMENTS CALLED FOR ON THESE DRAWINGS. 13. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR OMISSIONS BETWEEN THE DRAWINGS, THESE NOTES, AND FIELD CONDITIONS, AND REQUEST CLARIFICATION BEFORE COMMENCING ANY WORK. 14. EACH CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE RELATING TO THE WORK OF EACH TRADE. NO ALLOWANCE SHALL BE MADE FOR ANY EXTRA EXPENSE OR EXTENSION OF TIME DUE TO CONTRACTOR'S FAILURE OR NEGLIGENCE IN COMPLETELY EXAMINING THE JOBSITE. 15. THE GENERAL CONTRACTOR, SUBCONTRACTORS, AND ANY OTHER CONTRACTOR INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT ANY COSTS DUE TO DEFECTIVE AND/OR ILL-TIMED WORK AS A RESULT OF, BUT NOT LIMITED TO, INFERIOR WORKMANSHIP OR MATERIALS AND/OR IMPROPER SCHEDULING OR DELINQUENT ORDERING, SHALL BE BORNE BY THE PARTY RESPONSIBLE. 16. THE CONTRACTOR SHALL PROVIDE BLOCKING, BACKING, FRAMING HANGERS, OR OTHER SUPPORT FOR ALL FIXTURES, EQUIPMENT, CABINETRY, FURNISHINGS, AND ALL OTHER ITEMS AS REQUIRED. 17. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR DEFINITION, THE ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION. 18. ALL ITEMS ARE NEW UNLESS NOTED OTHERWISE. CONTRACTOR SHALL ENSURE THAT INSTALLATION METHODS CONFORM TO ALL BUILDING CODE REQUIREMENTS. THE MATERIALS SPECIFIED ARE INTENDED TO MEET CODE REQUIREMENTS. ANY DISCREPANCY BETWEEN THE CONSTRUCTION DOCUMENTS AND CODE REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY BY THE CONTRACTOR, AND PRIOR TO PERFORMANCE OF SPECIFIED WORK. 19. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALLER SCALE DETAILS. 20. DAMAGE TO WORK SHALL BE REPAIRED BY THE TRADE WHOSE WORK IS DAMAGED AND CHARGED TO THE PARTY RESPONSIBLE FOR THE DAMAGE. DEMOLITION REQUIREMENTS: 1. THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIAL AS REQUIRED TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED IN ARCHITECTS DRAWINGS OR AS OTHERWISE DIRECTED BY ARCHITECT. 2. THE GENERAL CONTRACTOR SHALL FURNISH ARCHITECT WITH A COMPLETE INVENTORY LIST OF ALL ITEMS THAT CAN BE REUSED AND/OR STORED IN BUILDING STOCK. 3. THE GENERAL CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE REGULATIONS OF THE BUILDING FOR DEMOLITION AND REMOVAL OF DEBRIS, INCLUDING OVERTIME WORK REQUIRED. 4. ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES, EXCEPT ITEMS TO BE REUSED OR RETURNED TO TENANT OR AS OTHERWISE NOTED. 5. THE GENERAL CONTRACTOR SHALL REMOVE FROM PREMISES CONDUITS LEFT AFTER WALL DEMOLITION, INCLUDING SWITCH BOXES, PLATES, BRIDGES, OR ANY OTHER TELEPHONE OR ELECTRICAL WIRING AND EQUIPMENT. 6. IN ALL AREAS WHERE DEMOLITION (REMOVAL OF TILE, CARPETING, TACKLESS, PARTITIONS, ETC.) CAUSES AN UNEVENNESS IN SLAB, THE CONTRACTOR SHALL PATCH TO LEVEL THE SLAB TO RECEIVE NEW FINISHED FLOORING. 7. THE GENERAL CONTRACTOR SHALL AT ALL TIMES PROTECT THE PROPERTY OF THE BUILDING OWNER, INCLUDING BUT NOT LIMITED TO, WINDOWS, FLOORS AND CEILING TILES, PUBLIC TOILETS, ELEVATORS, DOORS, BUCKS, ELECTRICAL AND AIR CONDITIONING EQUIPMENT, CONVECTOR ENCLOSURES, ETC. 8. THE GENERAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHTS THROUGHOUT THE SPACE UNDER CONSTRUCTION AS REQUIRED. 9. THE GENERAL CONTRACTOR SHALL CAP AND FLUSH OFF BEHIND FINISH SURFACE ALL PROJECTING PLUMBING, FLOOR ELECTRICAL/TELEPHONE OUTLETS, AND ALL OTHER PROJECTING ITEMS WHICH ARE BEING ABANDONED. 10. UPON COMPLETION OF THE DEMOLITION WORK, THE GENERAL CONTRACTOR SHALL PROVIDE THAT ALL AREAS BE LEFT BROOM CLEAN. 11. THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, FITTING AND PATCHING WORK THAT MAY BE REQUIRED TO MAKE ALL PARTS COME TOGETHER PROPERLY, AND FIT TO RECEIVE OR BE RECEIVED BY WORK OTHER CONTRACTORS SHOWN UPON OR REASONABLY IMPLIED BY THE DRAWINGS AND NOTES. 12. THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR CUT-OUTS AND PATCHING REQUIRED FOR INSTALLATION OF ALL WORK. 13. THE GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING PLASTER SURFACES AND WHERE, AS A RESULT OF DEMOLITION, FINISHED SURFACES DO NOT ALIGN THE EXISTING PLASTER SHALL BE CHOPPED AWAY, NEW CORNER BEADS AND STOPS INSTALLED AND SURFACES RE-PLASTERED TO A SMOOTH, FLUSH, ALIGNED SURFACE. D010 DEMOLITION NOTES DEMOLITION STANDARDS: 1. DEMOLISH EXISTING CONSTRUCTION WHERE INDICATED ON THE DRAWINGS AND REQUIRED BY JOB CONDITIONS. 2. PROTECT EXISTING CONSTRUCTION DESIGNATED TO REMAIN. 3. REMOVE DEMOLISHED ITEMS FROM THE SITE AND DISPOSE OF THEM IN A LEGAL MANNER. 4. DISCONNECTING, CUTTING, CAPPING, OR RELOCATING ANY ACTIVE UTILITY LINES ENCOUNTERED. 5. REFERENCE STANDARD ANSI A10.6 "SAFETY REQUIREMENTS FOR DEMOLITION" PUBLISHED BY THE AMERICAN NATIONAL STANDARDS INSTITUTE (A.N.S.I). 6. CEASE OPERATING AND IMMEDIATELY NOTIFY THE OWNER IF THE SAFETY OF EXISTING CONSTRUCTION APPEARS TO BE ENDANGERED AT ANY TIME. TAKE PRECAUTIONS TO SUPPORT SUCH ENDANGERED CONSTRUCTION AND DO NOT RESUME OPERATIONS UNTIL APPROPRIATE PROTECTION HAS BEEN PLACED. 7. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE ADEQUACY AND INSTALLATION OF ALL TEMPORARY SHORING SYSTEMS USED DURING THE REMOVAL OF ALL STRUCTURAL ELEMENTS. 8. NO EXISTING STRUCTURAL ELEMENTS (BEAM, SHEAR WALL, ETC.) SHALL BE REMOVED UNLESS CONTRACTOR IS PREPARED TO BEGIN INSTALLATION OF A NEW STRUCTURAL ELEMENT OR PROVIDE APPROVED TEMPORARY SHORING. 9. ALL DEMOLISHED MATERIALS SHALL BECOME THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF DEBRIS, UNLESS OTHERWISE DIRECTED BY THE OWNER. 10. REMOVE DEMOLISHED MATERIALS FROM THE SITE AND DISPOSE OF THEM IN A LEGAL MANNER. NO ON-SITE SALE OR BURNING OF DEMOLISHED MATERIALS WILL BE PERMITTED. 11. COMPLY WITH ALL STATE AND LOCAL REQUIREMENTS FOR RECYCLING OF MATERIALS. 12. THE DRAWINGS DO NOT NECESSARILY INDICATE THE FULL EXTENT OF THE WORK REQUIRED TO BE PERFORMED. CONTRACTOR SHALL CAREFULLY INSPECT THE EXISTING CONDITIONS TO DETERMINE THE FULL EXTENT OF WORK TO BE PERFORMED AND THE PROBLEMS INVOLVED. 13. ALL WORK SHALL BE PERFORMED BY SKILLED AND PROPERLY EQUIPPED PERSONNEL. DEMOLITION AND REMOVAL OF ITEMS SCAFFOLD HIGH OR HIGHER SHALL BE LOWERED BY CONTROLLED METHODS, NOT BY THROWING OR DROPPING. PERFORM CUTTING AND STRIPPING SO THAT THE WORK TO REMAIN IS UNDAMAGED AND IN SUCH MANNER THAT NEW WORK CAN BE PROPERLY CONNECTED WITH IT. 14. DEMOLISH EXISTING CONSTRUCTION TO THE EXTENT NECESSARY FOR THE PROPER INSTALLATION OF NEW CONSTRUCTION AND JUNCTION WITH EXISTING WORK.CUT BACK FINISHED SURFACE TO STRAIGHT, PLUMB AND LEVEL LINES AS REQUIRED. 15. SAWING SHALL BE PERFORMED BY EXPERIENCED CRAFTSMEN CUSTOMARILY ENGAGED IN AND PROPERLY EQUIPPED FOR THE PERFORMANCE OF THE TYPE OF WORK REQUIRED BY THE JOB CONDITION. PROVIDE WET VACUUM EQUIPMENT AS REQUIRED FOR CONTROL OF WASTE COOLING WATER. 16. REMOVE EXISTING CONSTRUCTION FOR INSTALLATION OF PIPING CONDUIT AND TUBING AS REQUIRED BY MECHANICAL AND ELECTRICAL TRADES. EXCEPTION: PIPING, CONDUIT, OR TUBING SHALL BE DONE BY THE TRADE INSTALLING THE PIPING, CONDUIT, OR TUBING. 17. REPAIR, RESTORE, OR REPLACE ANY DAMAGE TO EXISTING CONSTRUCTION WHICH OCCURS AS A RESULT OF DEMOLITION OPERATIONS, AT NO ADDITIONAL COST TO THE OWNER. THESE REPAIRS SHALL INCLUDE ANY ROOF PATCHING REQUIRED DUE TO DEMOLITION. COORDINATE WITH LANDLORD OR LANDLORD'S ROOFER. 18. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON THE PREMISES. PROVIDE FOR THE CONTINUOUS REMOVAL AND LEGAL OFF SITE DISPOSAL OF DEMOLISHED MATERIALS AS THE WORK PROGRESSES. DEMOLITION PREPARATION: 1. THE CONTRACTOR SHALL FURNISH EQUIPMENT AND PERFORM LABOR REQUIRED TO EXECUTE THIS WORK AS INDICATED ON THE DRAWINGS AND AS NECESSARY TO COMPLETE THE CONTRACT. 2. THE CONTRACTOR SHALL TAKE INTO CONSIDERATION AS NECESSARY WORK ALL OBVIOUS EXISTING CONDITIONS AND INSTALLATION ON THE SITE AS THOUGH THEY WERE COMPLETELY SHOWN OR DESCRIBED. ACCEPT THE SITE OF THE WORK AS IT EXISTS AND CLEAR OBSTRUCTION TO THE WORK INDICATED. 3. THE CONTRACTOR SHALL FIRST EXAMINE THE SITE AND ALL CONDITIONS AND LIMITATIONS THEREON AND THEREABOUTS, AND SHALL TAKE INTO ACCOUNT ALL SUCH CONDITIONS AND LIMITATION WHETHER OR NOT THE SAME ARE SPECIFICALLY SHOWN OR MENTIONED IN ANY OF THESE DOCUMENTS, INCLUDING WHATEVER SUMS ARE NEEDED TO COMPLETE THE WORK IN EVERY PART AS SHOWN, DESCRIBED, OR REASONABLY REQUIRED OR IMPLIED AND ATTAIN THE COMPLETED CONDITIONS. 4. THE CONTRACTOR SHALL TAKE CAREFUL NOTE THAT THE PREMISES AND ACTIVITIES WILL BE OPEN TO "BUSINESS AS USUAL" DURING THE COURSE OF THIS CONTRACT. NO INTERRUPTION OF TRAFFIC FLOW, UTILITIES SERVICES, OR OWNER'S USUAL ACTIVITIES WILL BE PERMITTED WITHOUT PREVIOUS SCHEDULING WITH THE OWNER. 5. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE BUILDING CODE HAVING JURISDICTION, THE GOVERNING STATE INDUSTRIAL SAFETY ORDERS, AND THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA). 6. THE CONTRACTOR SHALL INCLUDE MISCELLANEOUS CUTTING AND PATCHING NECESSARY TO REWORK ABUTTING SURFACES AS REQUIRED TO MAKE NEW WORK JOIN AND MATCH EXISTING SURFACES TO REMAIN. 7. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ON SEQUENCING AND PHASING OF VARIOUS PARTS OF THE WORK, SO THAT ALL FACILITIES AND SERVICES ARE MAINTAINED IN OPERATION UNTIL IMMEDIATELY BEFORE THEIR REMOVAL IS REQUIRED TO PERMIT INSTALLATION OF NEW WORK. 8. THE CONTRACTOR SHALL CARRY ON ALL WORK IN A MANNER WHICH WILL PRODUCE THE LEAST AMOUNT OF NOISE. INSTRUCT ALL WORKMEN IN NOISE CONTROL PROCEDURES. 9. THE CONTRACTOR SHALL CONTROL ALL DUST BY PREVENTING PENETRATION THROUGH NON-DEMOLISHED PARTS OF THE PREMISES AND OTHER ADJOINING AREAS. DEMOLITION EXECUTION: 1. PROVIDE PROTECTION AS REQUIRED TO PREVENT GLASS BREAKAGE. REPLACE ALL BROKEN GLASS WITH MATCHING MATERIAL. 2. PROVIDE HOISTS AND CHUTES AS REQUIRED TO LOWER REMOVED MATERIALS. THROWING, DROPPING, OR PERMITTING THE FREE FALL OF MATERIALS AND DEBRIS FROM HEIGHTS WHICH WOULD CAUSE DAMAGE TO WORK TO REMAIN. 3. UNDUE NOISE OR EXCESSIVE DUST IS EXPRESSLY PROHIBITED. 4. ERECT SIGNS, BARRICADES AND SUCH OTHER FORMS OF WARNING AS WAY BE REQUIRED TO PREVENT PERSONNEL FROM PUTTING THEMSELVES IN THE WAY OF INJURY. 5. PROVIDE SUCH FORMS OF PROTECTION AS MAY BE NECESSARY TO PREVENT DAMAGE TO EXISTING WORK OR EQUIPMENT TO REMAIN. 6. REMOVE PARTITION FINISHES, STUDS PLATES AND SILLS WHERE ONLY A PARTIAL RUN IS REMOVED. CUT BACK FINISH MATERIAL TO THE CENTER LINE OF THE NEXT ADJACENT SUPPORT TO REMAIN. LEAVE REMAINING MATERIAL WITH A CLEAN TERMINAL LINE WITH NO LOOSE MATERIAL. 7. CAREFULLY REVIEW EXISTING CONDITIONS AND DETERMINE UTILITY LINES TO BE REMOVED AND THOSE TO REMAIN ACTIVE OR TO BE REACTIVATED. PROTECT UTILITY LINES TO REMAIN. PROVIDE FOR MINIMUM SERVICE INTERRUPTION FOR UTILITY LINES TO REMAIN. 8. REMOVE UNNEEDED UTILITY LINES COMPLETELY WHEREVER POSSIBLE. CUT AND CAP OR PLUG IN A POSITIVE MANNER BEHIND THE BACK OF FINISH MATERIAL. 9. ALL DEBRIS SHALL BE REMOVED FROM THE SITE. DO NOT ALLOW MATERIALS AND DEBRIS GENERATED BY DEMOLITION ACTIVITIES TO ACCUMULATE. REMOVE DAILY AND DISPOSE OF IN A LEGAL MANNER. 10. LEAVE ALL SPACES BROOM CLEAN WITH ALL LEDGES AND CORNERS PROPERLY CLEANED. 11. REMOVE EXISTING FLOOR FINISHES AND PREPARE SUB-SURFACE TO RECEIVE NEW FLOOR AS REQUIRED. ADDITIONAL DEMOLITION NOTES: 1. REMOVAL OF EXISTING ELECTRICAL WORK SHALL INCLUDE CONDUIT, BOXES, WIRE CABLE, SUPPORTS, WIRING DEVICES, SAFETY SWITCHES, FIRE ALARM EQUIPMENT, SPEAKERS, LIGHTING FIXTURES, ETC. 2. UTILITIES STUBBED-UP FROM FLOOR AND SLAB ARE TO BE INTERCEPTED AND CAPPED BELOW FLOOR SLAB. 3. IF ASBESTOS IS DISCOVERED, THE CONTRACTOR SHALL IMMEDIATELY CEASE WORK IN THE AFFECTED AREA. THE OWNER SHALL ABATE ANY ASBESTOS UNDER A A SEPARATE AGREEMENT. 4. EXISTING PARTITIONS TO REMAIN SHALL BE PATCHED AS REQUIRED TO RECEIVE NEW FINISH AS SPECIFIED. 5. CARE SHALL BE TAKEN TO PROTECT EXISTING UTILITY LINES DURING DEMOLITION. 6. DO NOT DAMAGE ANY INTERIOR OR EXTERIOR WALLS OR COLUMNS TO REMAIN THAT SUPPORT THE ROOF STRUCTURE OR CANOPY. 7. PROVIDE ALL NECESSARY SHORING FOR DEMOLITION. PROVIDE SHOP DRAWING FOR SHORING. ALL SHORING SHALL BE REVIEWED BY THE ARCHITECT AND/OR STRUCTURAL ENGINEER. CONFIRM WHICH EXTERIOR WALLS OR COLUMNS SUPPORT THE FLOORS OR ROOF STRUCTURE ABOVE BEFORE DEMOLITION. 8. POWER AND SIGNAL DEMOLITION FOR ALL OUTLETS AND ALL TO BE DEMOLISHED WALLS. DISCONNECT AND REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO PANEL BOARDS OR NEAREST REMAINING OUTLET. 9. TURN OF POWER AT THE PANEL/SWITCH BOARDS FOR ALL EQUIPMENT SCHEDULED FOR REMOVAL OR DEMOLITION. LOCK THE DEVICE IN THE "OFF" POSITION, AND PROVIDE TAG IDENTIFYING EQUIPMENT SERVED AND ITS LOCATION. 10. REMOVE ALL FLEXIBLE DUCT, DIFFUSER, RELIEF GRILLES, HANGERS, ETC. IN SCOPE OF WORK AREA. ANY OPEN DUCT SHALL BE DAMPERED, SEALED, OR COVERED WITH VISQUENE TO MINIMIZE BLOWING DUST FROM THE CONSTRUCTION AREA. 11. MAINTAIN FIRE SPRINKLER SYSTEMS DURING DEMOLITION WORK. CONTACT OWNER'S REPRESENTATIVE PRIOR TO SHUTTING DOWN SYSTEM OR ANY PORTION OF THE SYSTEM. RESTORE ALL SYSTEM AT THE END OF EACH DAY OR WORK PERIOD. 12. DEMOLITION WORK TO BE COORDINATED WITH LANDLORD, PARTICULARLY IN PUBLIC AREAS AND/OR ADJOINING TENANT AREAS. -END- A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 6.26.25 A 2 40'-2" 9'-9"30'-5" 2 11 ' - 3 " 15 ' - 2 " 25 ' - 6 " 15'-2"5'-6"14'-91 2" (E) STOREFRONT GLAZING 11'-0" (E) ENTRY POP-OUT 27 ' - 4 1 2" 11 1DEMOLITION FLOOR PLAN 1/4" = 1'-0" (E) DRESSING ROOM (E) TOILET (E) ELECTRICAL (E) SALES AREA (E ) CO U N T E R (E) JAN D011 - 14'-6" STOREFRONT 7"1'-6"7" 31'-9" 1'-6" 1' - 6 " 10 ' - 6 " 9'-0" 13 ' - 6 " 6'-10"1'-6" 5 5 5 16 9 4 5 2 2 2 1 6 9 1 3 12 9 8 15 10 16 7 7 13 31 2" 11 1 2" 10 11 19 MA L L E N T R A N C E 4 A 2 40'-2" 9'-9"30'-5" 2 11 ' - 3 " 15 ' - 2 " 25 ' - 6 " 15'-2"5'-6"14'-91 2" (E) STOREFRONT GLAZING 11'-0" (E) ENTRY POP-OUT 27 ' - 4 1 2" 11 M 121 23 1DEMOLITION CEILING PLAN 1/4" = 1'-0" A 2 40'-2" 9'-9"30'-5" 2 11 ' - 3 " 15 ' - 2 " 25 ' - 6 " 15'-2"5'-6"14'-91 2" (E) STOREFRONT GLAZING 11'-0" (E) ENTRY POP-OUT 27 ' - 4 1 2" 11 DEMOLITION KEYNOTES 1 (E) GYP BD. TO REMAIN, PATCH, REPAIR AND PAINT AS NEEDED 2 REMOVE (E) INTERIOR PARTITION WALLS, SHELVES AND ALL UTILITIES ATTACHED TO WALLS. 6 REMOVE ENTIRE (E) RESTROOM PLUMBING/ELECTRICAL FIXTURES AND ACCESSORIES CAP ABANDON PIPES BELOW SLAB. SEE NEW FLOOR PLAN AND PLUMBING PLANS FOR NEW RESTROOM LAYOUT 3 (E) AC CEILING GRID, GRILLES, DIFFUSERS AND DUCTWORK TO REMAIN, (U.N.O.) REPLACE CEILING TILES WITH NEW, REPLACE LIGHTING WITH NEW, REWORK DUCTWORK AS NEED IN BREAKROOM & CONFERENCE ROOM 7 REMOVE PORTION OF (E) ENTRY POP-OUT FINISH (ALL PURPLE / VIOLET COLOR), PATCH AND REPAIR GYP BD. BEHIND AS NEEDED. REMOVE (E) ENTIRE FLOOR FINISHES. SEE GENERAL NOTE #1. 4 (E) ELECTRICAL PANELS, METER AND ALL THE WIRING/CONDUITS IN THIS AREA TO REMAIN 5 9 8 10 11 12 13 EXISTING INTERIOR WALL, DOOR AND FRAME TO REMAIN, PATCH AND REPAIR IF NEEDED. 14 15 EXISTING SPRINKLER HEAD / MAIN LINE TO REMAIN AND PROTECT. (+16'-0" (E) RCP) (+10'-0" RCP) (+9'-5") (+7'-10") (E)(+8'-0") (+10'-0") (+8'-0") (+8'-0") (E) OVERHEAD SOFFIT AND LIGHTS ABOVE STOREFRONT (ON MALL SIDE), TO REMAIN. PATCH, PAINT AND REPAIR AS NEEDED EXISTING EXTERIOR WALL TO REMAIN. REMOVE (E) MILLWORK COUNTER/SEATING AND MISCELLANEOUS FLOOR PLATFORMS.. EXISTING STOREFRONT GLAZING TO REMAIN. EXISTING STRUCTURAL COLUMN AND FURRING TO REMAIN. REMOVE (E)MIRROR FINISH, PATCH AND REPAIR FURRING AS NEEDED. EXISTING MALL ENTRANCE (N.A.P.) PROTECT IN PLACE. 16 REMOVE (E) ACCORDION DOOR, ACCESSORIES AND DOOR CABINET. 3 EXISTING CEILING TO REMAIN. PATCH, REPAIR AND REPAINTED.17 (E) EXHAUST FAN AND DIFFUSER TO REMAIN, REPLACE LIGHT FIXTURE WITH NEW LIGHTS, PATCH AND REPAIR CEILING AS NEEDED.18 3 17 18 8 137 14 14 TYP. 18 18 19 PORTION OF (E) ENTRY POP-OUT FINISH TO REMAIN (WHITE COLOR FINISH ALL AROUND), PATCH AND REPAIR IF NEEDED. 16 16 12 197 MA L L E N T R A N C E 20 (E) OVERHEAD SOFFIT AND LIGHTS ABOVE STOREFRONT (INSIDE SPACE) TO REMAIN, PAINT 17 20 20 21 REMOVE (E) DOOR AND REPLACE WITH NEW GLASS DOOR, ADJUST OPENING ACCORDINGLY FOR NEW DOOR PLACEMENT, SEE NEW FLOOR PLAN 22 REMOVE (E) ACT CEILING GRID, LIGHTS AND DIFFUSERS, GC TO RE-USE CEILING GRID IF POSSIBLE AND REPLACE ALL NEW LIGHTS, DIFFUSER AND RE-WORK DUCTING IN THIS AREA. ALTERNATIVELY - PROVIDE ALL NEW ACT CEILING GRID AND TILES 22 23 REMOVE (E) DOOR AND INFILL WALL DEMO FLOOR LEGEND 1. SEE DEMOLITION NOTES ON SHEET D010 FOR REFERENCE. 2. G.C. SHALL GRIND AND POLISH THE CONCRETE FLOOR TO TENANT'S SPECIFICATIONS. 3. REPAIR DAMAGE CONCRETE SLAB AND HEADER OPENING AS A RESULT OF DEMOLITION. GENERAL NOTES DEMOLITION KEYNOTES 1 (E) GYP BD. TO REMAIN, PATCH, REPAIR AND PAINT AS NEEDED 2 REMOVE (E) INTERIOR PARTITION WALLS, SHELVES AND ALL UTILITIES ATTACHED TO WALLS. 6 REMOVE ENTIRE (E) RESTROOM PLUMBING/ELECTRICAL FIXTURES AND ACCESSORIES CAP ABANDON PIPES BELOW SLAB. SEE NEW FLOOR PLAN AND PLUMBING PLANS FOR NEW RESTROOM LAYOUT 3 (E) AC CEILING GRID, GRILLES, DIFFUSERS AND DUCTWORK TO REMAIN, (U.N.O.) REPLACE CEILING TILES WITH NEW, REPLACE LIGHTING WITH NEW, REWORK DUCTWORK AS NEED IN BREAKROOM & CONFERENCE ROOM 7 REMOVE PORTION OF (E) ENTRY POP-OUT FINISH (ALL PURPLE / VIOLET COLOR), PATCH AND REPAIR GYP BD. BEHIND AS NEEDED. REMOVE (E) ENTIRE FLOOR FINISHES. SEE GENERAL NOTE #1. 4 (E) ELECTRICAL PANELS, METER AND ALL THE WIRING/CONDUITS IN THIS AREA TO REMAIN 5 9 8 10 11 12 13 EXISTING INTERIOR WALL, DOOR AND FRAME TO REMAIN, PATCH AND REPAIR IF NEEDED. 14 15 EXISTING SPRINKLER HEAD / MAIN LINE TO REMAIN AND PROTECT. (E) OVERHEAD SOFFIT AND LIGHTS ABOVE STOREFRONT (ON MALL SIDE), TO REMAIN. PATCH, PAINT AND REPAIR AS NEEDED EXISTING EXTERIOR WALL TO REMAIN. REMOVE (E) MILLWORK COUNTER/SEATING AND MISCELLANEOUS FLOOR PLATFORMS.. EXISTING STOREFRONT GLAZING TO REMAIN. EXISTING STRUCTURAL COLUMN AND FURRING TO REMAIN. REMOVE (E)MIRROR FINISH, PATCH AND REPAIR FURRING AS NEEDED. EXISTING MALL ENTRANCE (N.A.P.) PROTECT IN PLACE. 16 REMOVE (E) ACCORDION DOOR, ACCESSORIES AND DOOR CABINET. EXISTING CEILING TO REMAIN. PATCH, REPAIR AND REPAINTED.17 (E) EXHAUST FAN AND DIFFUSER TO REMAIN, REPLACE LIGHT FIXTURE WITH NEW LIGHTS, PATCH AND REPAIR CEILING AS NEEDED.18 19 PORTION OF (E) ENTRY POP-OUT FINISH TO REMAIN (WHITE COLOR FINISH ALL AROUND), PATCH AND REPAIR IF NEEDED. 20 (E) OVERHEAD SOFFIT AND LIGHTS ABOVE STOREFRONT (INSIDE SPACE) TO REMAIN, PAINT 21 REMOVE (E) DOOR AND REPLACE WITH NEW GLASS DOOR, ADJUST OPENING ACCORDINGLY FOR NEW DOOR PLACEMENT, SEE NEW FLOOR PLAN 22 REMOVE (E) ACT CEILING GRID, LIGHTS AND DIFFUSERS, GC TO RE-USE CEILING GRID IF POSSIBLE AND REPLACE ALL NEW LIGHTS, DIFFUSER AND RE-WORK DUCTING IN THIS AREA. ALTERNATIVELY - PROVIDE ALL NEW ACT CEILING GRID AND TILES 23 REMOVE (E) DOOR AND INFILL WALL DEMO FLOOR LEGEND (E) INTERIOR ITEMS TO BE REMOVED: WALLS, DOORS, PLUMBING FIXTURES, ETC. (E) EXTERIOR WALL TO REMAIN. (E) INTERIOR WALL TO BE REMOVED (E) STOREFRONT WINDOWS TO REMAIN (E) CEILING GRID TO REMAIN, REPLACE PANEL D011 DEMOLITION FLOOR PLAN AND CEILING PLAN A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 NORTH NORTH R1 R1 R1 R1 R1 R1 R1 R1 R1 R2 R2 R2 R2 R2 R2 6.26.25 1OVERALL MALL LEASE PLAN 1" = 50'-0" PROPOSED MARKETING OFFICE SEE ENLARGED PLAN ON SHEET A101 AREA: 1,095 S.F. MANAGER'S OFFICE ADJACENT TENANT M CONFERENCE ROOM BREAKROOM OPEN OFFICE ADJACENT TENANT STO. TOILET OFFICE A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 NORTH A010 OVERALL MALL LEASE PLAN (FOR REFERENCE ONLY) ( F O R R E F E R E N C E O N L Y ) R2 R2 6.26.25 A 2 40'-2" 9'-9"30'-5" 2 11 ' - 3 " 15 ' - 2 " 25 ' - 6 " 15'-2"5'-6"14'-91 2" (E) STOREFRONT GLAZING 11'-0" (E) ENTRY POP-OUT 27 ' - 4 1 2" 11 M GRAB BARTRADITIONALK-10545 GRAB BARTRADITIONALK-10544 BATHROOM SINKMODERNLIFEK-77767-1 1FLOOR PLAN 1/4" = 1'-0" NEW ALL-GENDER TOILET 7"1'-6"7"6'-10"1'-6" 4'-0" 31'-9" 12 ' - 0 " 17'-10"12'-5" V.I.F. 9'-0" CONFERENCE ROOM MANAGER'S OFFICE REF 10 ' - 7 " 5' - 3 " 8'- 1 0 " 13 ' - 6 " A2 A1 A3 A401 1 D101 D102 D104 3 2 1 1 1 1 BREAKROOM 1 6 A201 2 7 4 S1 9 9 8 8 1 8 B A A201 4 A201 3B A201 3A A201 17 A201 18 6 D103 3'-0"3'-4"6" A2 A3 A4 A4 A3 MA L L E N T R A N C E 10 A301 13 ALL FURNISHINGS, DESK, CHAIRS, TABLES ETC. TO BE FURNISHED AND INSTALLED BY OWNER A301 1 A301 9 14 18" MIN. 12" MIN. 18" MIN. 12" MIN. 30x48 CLR 60"x60" clr. 60 " x 6 0 " c l r . 48 " x 4 8 " c l r . COPY ROOM 15 16 60"x60" clr. 48"x48" clr. 12 " MI N . 18 " MI N . NEW FRAMELESS ENTRY DOOR/GLASS UNDER DEFERRED SUBMITTAL 60"x60" clr. 48"x48" clr. (E) CLOSET A2 D105 OFFICE MATCH ADJ WALL SIZE 5'-0 " TUR N I N G R A D I U S A201 16 GENERAL NOTES KEYNOTES 1 NEW ENTRY POP-OUT FINISH TO MATCH ADJACENT FINISH. COLOR TO BE DARK GREY. 2 NEW WALL GLAZING, SEE ELEVATION SHEET A201 6 3 NEW WALL TO BE FLUSH WITH EXISTING COLUMN, SEE DETAIL 20/A401 7 NEW FLOOR FINISH FOR THE ENTIRE SPACE. LVT FLOORING BY: ARMSTRONG - RIBE: J7207 4 KITCHEN BUYOUT CABINETS AND SHELVES BY GENERAL CONTRACTOR COUNTERTOP AND BACKSPLASH: BY CAMBRIA - PORTRUSH - POLISHED CAMBRIA 5 9 8 10 EXISTING CEILING GYP. BOARD TO REMAIN. PATCH & REPAIR IF NEEDED. ADD NEW LIGHTS 1. INTERIOR WALLS SHALL BE TAPED, SANDED SMOOTH (LEVEL 4) AND READY FOR TENANT FINISH . 2. INTERIOR FLOOR SLABS TO BE SMOOTH TROWELED FINISH (FF = 35, FL = 25), UNSEALED, AND READY FOR TENANT FINISH. 3. DOOR SCHEDULE REFER TO SHEET A601. WALL LEGEND EXIT DOOR EXISTING INTERIOR WALL TO REMAIN, PROTECT IN PLACE NEW STUD WALLS - SEE INTERIOR PARTITION KEYNOTES EXISTING EXTERIOR WALL TO REMAIN, PROTECT IN PLACE EXIT 3-5/8" x 20 GA. METAL STUD WALL AT 16" O.C., WITH 5/8" GYP. BOARD ON ONE (1) SIDE, WITH SOUND BATT INSULATION. SEE DETAIL 17/A301. 3-5/8" x 20 GA. METAL STUD WALL AT 16" O.C. WITH 5/8" GYP. BOARD BOTH SIDE WITH SOUND BATT INSULATION. EXTEND TO 6" ABOVE HIGHEST ADJACENT CEILING. SEE DETAIL 17/A301 EXISTING WALL PARTITION TO REMAIN. PATCH AND REPAIR IF NEEDED. EXISTING DEMISING WALL TO REMAIN. PATCH AND REPAIR IF NEEDED STOREFRONT WINDOW - SEE DETAIL INTERIOR PARTITION KEY NOTES A1 A2 A3 PORTION OF (E) ENTRY POP-OUT FINISH TO REMAIN (WHITE COLOR FINISH ALL AROUND), PATCH AND REPAIR IF NEEDED AND CLEAN TO LOOK "NEW" 2' X 4' RECESSED LIGHT FIXTURE, SEE ELECTRCAL CEILING TILE SYSTEM. 4' CEILING MOUNTED FLUORESCENT MECHANICAL HVAC DIFFUSER (SUPPLY) EXISTING SPRINKLER HEAD TO REMAIN MECHANICAL HVAC DIFFUSER (RETURN) MEACHANICAL DIFFUSER (EXHAUST) 9'-0"BOTTOM OF CEILING / SOFFIT LEGEND S# WALL PANELS FINISH - COMMAND WALL COVERINGS WOODGRAIN PATTERN, COLOR: PINE CMI 47-2792 EXISTING METER AND ELECTRICAL PANEL TO REMAIN 2' X 4' RECESSED EMERGENCY LIGHT FIXTURE, SEE ELECTRCAL OVERALL WALL PAINT - UNLESS NOTED OTHERWISE. DUNN EDWARDS: IGLOO DEW379, EGGSHELL FINISH. SEMI-GLOSS - SEE SHEET A401 FOR TOILET FINISHES. PLANTERS A4 11 EXISTING ACT CEILING GRID AND DIFFUSERS TO REMAIN, REPLACE NEW ACT TILES AND REPLACE NEW LIGHTS (SEE ELECTRICAL) 12 13 EXISTING EXHAUST FAN TO BE RELOCATED AS NEEDED OR LEAVE IN PLACE (SEE MECHANICAL AND ELECTRICAL) 14 DOOR SCHEDULE DOOR SIGNAGE - A. EACH GRADE-LEVEL EXIT DOOR TO HAVE A TACTILE SIGN WITH THE WORD "EXIT". SEE DETAIL 7A/T102 . B. POST A SIGN ADJACENT TO THE REQUIRED MAIN DOOR WITH 1" LETTERING STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". MAIN EXIT ONLY. PER CBC SECTION 1008.1.9.3. C. AT BUILDING ENTRANCE THAT IS ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES PROVIDE ACCESSIBLE SIGNAGE - SIGN TO DISPLAY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. SEE SHEET T102 60 " x 6 0 " c l r . 48 " x 4 8 " c l r . 60" CLEARANCE ON DOOR SWING DIRECTION PER CBC 11B-404.2.4 48" CLEARANCE ON OPPOSITE DIRECTION OF DOOR SWING DIRECTION PER CBC 11B-404.2.4 15 NEW GLASS DOOR, ADJUST OPENING ACCORDINGLY TO PROVIDE REQ'D DOOR CLEARANCE, SEE SHEET A601 6" DIA. LED INTERIOR RECESSED DOWNLIGHT, SEE ELECTRICAL 16 FUTURE WATER DISPENSER, SEE PLUMBING GC TO RE-USE CEILING GRID IF POSSIBLE AND REPLACE ALL NEW LIGHTS, DIFFUSER AND RE-WORK DUCTING IN THIS AREA. ALTERNATIVELY - PROVIDE ALL NEW ACT CEILING GRID AND TILES 2' X 2' RECESSED LIGHT FIXTURE, SEE ELECTRCAL 17 NEW GYP CEILING, AND LIGHTS IN NEW RELOCATED RESTROOM (E) CEILING GRID TO REMAIN, REPLACE PANEL 1REFLECTED CEILING PLAN 1/4" = 1'-0" A 2 40'-2" 9'-9"30'-5" 2 11 ' - 3 " 15 ' - 2 " 25 ' - 6 " 15'-2"5'-6"14'-91 2" (E) STOREFRONT GLAZING 11'-0" (E) ENTRY POP-OUT 27 ' - 4 1 2" 11 M EXIT 6 67 EQ.EQ. EQ . EQ . +10'-0" +8'-0" 5 MA L L E N T R A N C E EQ . 11 13 A301 1 A301 9 17 5 11 12 11 +8'-0" +7'-0" (E) (E) (E) +10'-0" +10'-0" (E) (+9'-5") EQ . 3' - 8 1 2" A101 FLOOR PLAN AND CEILING PLAN A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 NORTH NORTH PC1 PC1 PC1 PC1 PC1 PC1 PC2 PC2 PC3 PC2 PC3 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2 R2.1 R2.1 R2.1 R2.1 6.26.25 PROPOSED MARKETING OFFICE SEE ENLARGED PLAN ON SHEET A101 AREA: 1,095 S.F. CONFERENCEROOM MANAGER'SOFFICE KITCHEN TOILET STO. OFFICE 1EXISTING ROOF PLAN 1/4" = 1'-0" EXISTING MACY'S BLDG N.A.P. (E) ROOF TOP UNIT TO REMAIN N.A.P (E) ROOF TOP UNIT TO REMAIN N.A.P (E) ROOF TOP UNIT TO REMAIN N.A.P (E) ROOF TOP UNIT TO REMAIN N.A.P (E) UNIT SERVING SPACE TO REMAIN A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 NORTH A102 EXISTING ROOF PLAN KEYPLAN 6.26.25 ± 0'-0" SECOND FLOOR ± 16'-0" MALL CEILING ± 0'-0" SECOND FLOOR ± 16'-0" MALL CEILING A A ADJACENT TENANT MALL EXTERIOR PART ADJACENT TENANT MALL EXTERIOR PART 1 DEMOLITION STOREFRONT ELEVATION 1/4" = 1'-0" 2 STOREFRONT ELEVATION 1/4" = 1'-0" (E ) 1 4 ' - 8 " 8' - 0 " 11'-0" (E) PORTAL ENTRY (E ) 9 ' - 4 " V . I . F . B. O . S O F F I T 14'-6" (E) STOREFRONT 1 62 7 5 8 9 5' - 6 " 1' - 2 " 6'-10" (N) ENTRY OPEN TO BREAKROOM 17'-10" 10 ' - 0 " B. O . C E I L I N G 3INTERIOR ELEVATION 1/4" = 1'-0" 4KITCHEN ELEVATIONS 1/4" = 1'-0" AB AB 4 7 58'- 0 " A601 17 4'-0" A601 15 T T T 10 ' - 0 " B. O . C E I L I N G A601 13B A601 13C A601 13A 23 23 A301 1 3 4 S1 NOTE: FOR DOOR SCHEDULE REFER TO SHEET A601 A301 9 A301 1 A301 9 (E ) 9 ' - 4 " V . I . F . T. O . S T O R E F R O N T A601 16 A401 6B 25 26 26 FLOOR CLOSER ADJUSTABLE TOP PIVOT 111112 13 14 15 16 17 14 181824 24 10 ' - 0 " B. O . C E I L I N G T 1 17'-3"3'-0"5'-4"2'-2" KEYNOTES 1 NEW ENTRY POP-OUT FINISH TO MATCH ADJACENT FINISH. (COLOR TO BE DARK GREY) SEE DETAIL 17 & 18 ON SHEET A201 2 6 3 7 4 5 9 8 10 11 12 PORTION OF (E) ENTRY POP-OUT FINISH TO REMAIN (WHITE COLOR FINISH ALL AROUND), PATCH AND REPAIR IF NEEDED AND CLEAN TO LOOK "NEW" REMOVE PORTION OF (E) ENTRY POP-OUT FINISH (ALL PURPLE / VIOLET COLOR), PATCH AND REPAIR IF NEEDED. EXISTING EXTERIOR WALL TO REMAIN. EXISTING STOREFRONT GLAZING TO REMAIN. EXISTING MALL ENTRANCE (N.A.P.) PROTECT IN PLACE. REMOVE (E) ACCORDION DOOR, ACCESSORIES AND DOOR CABINET. (E) STOREFRONT OVERHANG CANOPY ON MALL SIDE TO REMAIN. PATCH, REPAIR AND REPAINTED. NEW STOREFRONT ENTRANCE - SEE DETAIL EXISTING DOOR TO REMAIN. G.C. TO CHECK ALL ACCESSORIES IF STILL WORKING PROPERLY. IF NOT G.C. TO INFORM OWNER OR ARCHITECT FOR REPLACEMENT. GFI OUTLET, TYP. 8" TO BOTTOM OF PLATE ABOVE COUNTER KITCHEN SINK - 33" x 22" SINGLE BOWL GRANITE BY: KRAUS - KGTW2-33 - METALLIC BLACK INSTANT FLOW WATER HEATER. PROVIDE GFI OUTLET. SEE PLUMBING AND ELECTRICAL FOR ADDITIONAL INFORMATION BUYOUT CABINETS AND SHELVES BY GENERAL CONTRACTOR HARDWARE:SOFT CLOSE HINGES & SOFT CLOSE UNDERMOUNT DRAWER SLIDES HANDLES AND PULLS: 4" DAMON EDGE BRUSHED BRASS DRAWER PULL REFRIGERATOR LOCATION, SEE ELECTRICAL DRAWINGS. REFRIGERATOR FINISH AND MODEL BY OWNER. 13 14 KITCHEN FAUCET - BY: KRAUS (KPF-2841) MATTE BLACK, SPOT FREE SEE PLUMBING SCHEDULE AND DRAWINGS. SUBMIT SPECS TO OWNER AND ARCHITECT FOR APPROVAL 15 MICROWAVE LOCATION, PROVIDE DEDICATED 20AMP SEPARATE CIRCUIT OR PER CODE. SEE ELECTRICAL DWGS. 16 17 KITCHEN BACKSPLASH: QUARTZ COUNTERTOP BY: CAMBRIA - PORTRUSH - POLISHED CAMBRIA18 NOT USED19 NOT USED20 NOT USED21 NOT USED22 DOOR HANDLE PER MANUFACTURER, SUBMIT SHOP DRAWINGS BY: PINKS - LOCK WITH LEVER IN BLACK23 QUARTZ COUNTERTOP BY: CAMBRIA - PORTRUSH - POLISHED CAMBRIA24 WALL PANELS FINISH - COMMAND WALL COVERINGS WOODGRAIN PATTERN, COLOR: PINE CMI 47-279225 PRIVACY FILM ON GLASS - FROSTED WHITE26 19NOT USED 20NOT USED 17ENTRY POP-OUT DETAIL 1" = 1'-0" 18ENTRY POP-OUT DETAIL 1" = 1'-0" (E) 2'-1" (V.I.F.) (E) 1'-6"7" 5" 412" (E ) 1 1 1 2" NEW ENTRY POP-OUT FINISH TO MATCH ADJACENT, COLOR TO BE DARK GRAY. 5/8" GYP. BD. OVER 2-1/2" METAL STUD @ 12" O.C. NEW DOOR ENTRY STOREFRONT ADJACENT TENANT (N.A.P.) (E) ENTRY POP-OUT FINISH TO REMAIN, PATCH & REPAIR IF NEEDED. CLEAN TO LOOK "NEW" 2'-1" (V.I.F.) 11 " ( V . I . F . ) 1' - 1 0 1 2" ( V . I . F . ) (E) 2'-1" (V.I.F.) 7"(E) 1'-6" NEW DOOR ENTRY STOREFRONT 1'-8" 1' - 1 0 1 2" ( V . I . F . ) 11 " ( V . I . F . ) (E ) 1 1 1 2" EXISTING STOREFRONT 5/8" GYP. BD. OVER 2-1/2" METAL STUD @ 12" O.C. (E) WALL INTERIOR, PATCH AND REPAIR IF NEEDED AFFECTED BY DEMO. (E) WALL INTERIOR, PATCH AND REPAIR IF NEEDED AFFECTED BY DEMO. NEW ENTRY POP-OUT FINISH TO MATCH ADJACENT, COLOR TO BE DARK GRAY. (E) ENTRY POP-OUT FINISH TO REMAIN, PATCH & REPAIR IF NEEDED. CLEAN TO LOOK "NEW" (E) AUTO FIRE SYSTEM #1 TO REMAIN A601 18 SIM. A601 18 SIM. FRAMELESS GLASS FRAMELESS GLASS 16KITCHEN SINK PARALLEL APPROACH 3/4" =1'-0" SINK BEYOND BUYOUT CABINETS BY GENERAL CONTRACTOR 2'- 1 0 " MA X I M U M H E I G H T A F F 2'-0" 46 " M A X . 30" A201 DEMO & PROPOSED STOREFRONT ELEVATION & INTERIOR ELEVATIONS A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 PC1 PC1 PC1 PC2 PC2 PC2 PC3 PC3 PC2 R1 R1 R1 R1 R1 R1 R1 R1 R2 R2 R2 R2 R2.1 R2.1 6.26.25 PAINTING SPECIFICATION A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 A203 PAINTING SPECIFICATION PART 1 - GENERAL 1.01 SUMMARY A. SECTION INCLUDES: SURFACE PREPARATION AND FIELD PAINTING OF EXPOSED ITEMS AND SURFACES ON THE FOLLOWING SUBSTRATES: 1. EXTERIOR: A. EXTERIOR PORTLAND CEMENT PLASTER. B. CONCRETE MASONRY UNITS (CMU). C. WOOD. D. STEEL. E. GALVANIZED METAL. 2. INTERIOR: A. GYPSUM BOARD. B. WOOD. C. CONCRETE MASONRY UNITS (CMU). D. STEEL. E. GALVANIZED METAL. 1.02 SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. INCLUDE PREPARATION REQUIREMENTS AND APPLICATION INSTRUCTIONS. B. SAMPLES FOR VERIFICATION: FOR EACH TYPE OF PAINT SYSTEM AND EACH COLOR AND GLOSS OF TOPCOAT. 1. SUBMIT SAMPLES ON RIGID BACKING, 8 INCHES SQUARE. 2. STEP COATS ON SAMPLES TO SHOW EACH COAT REQUIRED FOR SYSTEM. 3. LABEL EACH COAT OF EACH SAMPLE, 4. LABEL EACH SAMPLE FOR LOCATION AND APPLICATION AREA. C. PRODUCT LIST: FOR EACH PRODUCT INDICATED, INCLUDE THE FOLLOWING: 1. CROSS-REFERENCE TO PAINT SYSTEM AND LOCATIONS OF APPLICATION AREAS. USE SAME DESIGNATIONS INDICATED ON DRAWINGS AND IN SCHEDULES. 2. VOC CONTENT. D. CERTIFICATION BY MANUFACTURER THAT PRODUCTS SUPPLIED COMPLY WITH THE FOLLOWING REGULATIONS CONTROLLING USE OF VOLATILE ORGANIC COMPOUNDS (VOCS): 1. AIR QUALITY MANAGEMENT DISTRICT (AQMD), RULE 1113, ARCHITECTURAL COATINGS. 2. SECTION 5.504.4.3 AND TABLE 5.504.4.3, VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS, OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 5, NONRESIDENTIAL MANDATORY MEASURES. 1.03 QUALITY ASSURANCE A. MOCKUPS: APPLY MOCKUPS OF EACH PAINT SYSTEM INDICATED AND EACH COLOR AND FINISH SELECTED TO VERIFY PRELIMINARY SELECTIONS MADE UNDER SAMPLE SUBMITTALS AND TO DEMONSTRATE AESTHETIC EFFECTS AND SET QUALITY STANDARDS FOR MATERIALS AND EXECUTION. 1. ARCHITECT WILL SELECT ONE SURFACE TO REPRESENT SURFACES AND CONDITIONS FOR APPLICATION OF EACH PAINT SYSTEM SPECIFIED IN PART 3. A. VERTICAL AND HORIZONTAL SURFACES: PROVIDE SAMPLES OF AT LEAST 100 SQ. FT. B. OTHER ITEMS: ARCHITECT WILL DESIGNATE ITEMS OR AREAS REQUIRED. 2. FINAL ACCEPTANCE OF COLOR SELECTIONS WILL BE BASED ON MOCKUPS. 3. ACCEPTANCE OF MOCKUPS DOES NOT CONSTITUTE ACCEPTANCE OF DEVIATIONS FROM THE CONTRACT DOCUMENTS CONTAINED IN MOCKUPS UNLESS ARCHITECT SPECIFICALLY REVIEWS AND ACCEPTS SUCH DEVIATIONS IN WRITING. 4. SUBJECT TO COMPLIANCE WITH REQUIREMENTS, ACCEPTED MOCKUPS MAY BECOME PART OF THE COMPLETED WORK IF UNDISTURBED AT TIME OF SUBSTANTIAL COMPLETION. 1.04 DELIVERY, STORAGE, AND HANDLING A. STORE MATERIALS NOT IN USE IN TIGHTLY COVERED CONTAINERS IN A WELL-VENTILATED AREAS WITH AMBIENT TEMPERATURES CONTINUOUSLY MAINTAINED AT NOT LESS THAN 45 DEGREES F. 1. MAINTAIN CONTAINERS IN A CLEAN CONDITION, FREE OF FOREIGN MATERIALS AND RESIDUE. 2. REMOVE RAGS AND WASTE FROM STORAGE AREAS DAILY. 1.05 FIELD CONDITIONS A. APPLY PAINTS ONLY WHEN TEMPERATURES OF SURFACES TO BE PAINTED AND AMBIENT TEMPERATURES ARE BETWEEN 50 AND 95 DEGREES F. B. EXTERIOR: DO NOT APPLY PAINTS IN SNOW, RAIN, FOG, OR MIST; WHEN RELATIVE HUMIDITY EXCEEDS 85 PERCENT; AT TEMPERATURES LESS THAN 5 DEGREES F ABOVE THE DEW POINT; OR TO DAMP OR WET SURFACES. C. INTERIOR: DO NOT APPLY PAINTS WHEN RELATIVE HUMIDITY EXCEEDS 85 PERCENT; AT TEMPERATURES LESS THAN 5 DEGREES F ABOVE THE DEW POINT; OR TO DAMP OR WET SURFACES. 1.06 MAINTENANCE A. EXTRA MATERIALS: FURNISH EXTRA MATERIALS, FROM THE SAME PRODUCT RUN, THAT MATCH PRODUCTS INSTALLED AND THAT ARE PACKAGED WITH PROTECTIVE COVERING FOR STORAGE AND IDENTIFIED WITH LABELS DESCRIBING CONTENTS. 1. PAINT: 5 PERCENT, BUT NOT LESS THAN 1 GAL. OF EACH MATERIAL AND COLOR APPLIED. PART 2 - PRODUCTS 2.01 MANUFACTURERS A. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: 1. DUNN-EDWARDS CORPORATION, LOS ANGELES, CA (888) 337-2468; WWW.DUNNEDWARDS.COM. 2. BENJAMIN-MOORE, MONTVALE, NJ, (855) 724-6802; WWW.BENJAMINMOORE.COM 4. SHERWIN-WILLIAMS, CLEVELAND, OH (800) 474-3794; WWW.SHERWIN-WILLIAMS.COM. 5. VISTA PAINT, FULLERTON, CA (714) 680-3800; WWW.VISTAPAINT.COM. 2.02 PAINT MATERIALS, GENERAL A. MATERIAL COMPATIBILITY: 1. PROVIDE MATERIALS FOR USE WITHIN EACH PAINT SYSTEM THAT ARE COMPATIBLE WITH ONE ANOTHER AND SUBSTRATES INDICATED, UNDER CONDITIONS OF SERVICE AND APPLICATION AS DEMONSTRATED BY MANUFACTURER, BASED ON TESTING AND FIELD EXPERIENCE. 2. FOR EACH COAT IN A PAINT SYSTEM, PROVIDE PRODUCTS RECOMMENDED IN WRITING BY MANUFACTURERS OF TOPCOAT FOR USE IN PAINT SYSTEM AND ON SUBSTRATE INDICATED. B. VOC CONTENT: PROVIDE MATERIALS THAT COMPLY WITH VOC LIMITS OF AIR QUALITY MANAGEMENT DISTRICT (AQMD), RULE 1113, ARCHITECTURAL COATINGS, AND THE FOLLOWING: 1. COMPLY WITH SECTION 5.504.4.3 AND TABLE 5.504.4.3, VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS, OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 5, NONRESIDENTIAL MANDATORY MEASURES. C. COLORS: AS SELECTED BY ARCHITECT. PART 3 - EXECUTION 3.01 EXAMINATION A. EXAMINE SUBSTRATES AND CONDITIONS, WITH APPLICATOR PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT AND OTHER CONDITIONS AFFECTING PERFORMANCE OF WORK. B. MAXIMUM MOISTURE CONTENT OF SUBSTRATES: WHEN MEASURED WITH AN ELECTRONIC MOISTURE METER AS FOLLOWS: 1. CONCRETE AND MASONRY (CLAY AND CMU): 3 PERCENT. 2. WOOD: 15 PERCENT. 3. PORTLAND CEMENT PLASTER: 12 PERCENT. 4. GYPSUM BOARD: 12 PERCENT. C. PORTLAND CEMENT PLASTER SUBSTRATES: VERIFY THAT PLASTER IS FULLY CURED. D. EXTERIOR GYPSUM BOARD SUBSTRATES: VERIFY THAT FINISHING COMPOUND IS SANDED SMOOTH. E. VERIFY SUITABILITY OF SUBSTRATES, INCLUDING SURFACE CONDITIONS AND COMPATIBILITY WITH EXISTING FINISHES AND PRIMERS. F. BEGIN COATING APPLICATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED AND SURFACES ARE DRY. 1. APPLICATION OF COATING INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS. 3.02 PREPARATION A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS IN MPI MANUAL APPLICABLE TO SUBSTRATES AND PAINT SYSTEMS INDICATED. B. REMOVE HARDWARE, COVERS, PLATES, AND SIMILAR ITEMS ALREADY IN PLACE THAT ARE REMOVABLE AND NOT TO BE PAINTED. IF REMOVAL IS IMPRACTICAL OR IMPOSSIBLE BECAUSE OF SIZE OR WEIGHT OF ITEM, PROVIDE SURFACE-APPLIED PROTECTION BEFORE SURFACE PREPARATION AND PAINTING. 1. AFTER COMPLETING PAINTING OPERATIONS, USE WORKERS SKILLED IN THE TRADES INVOLVED TO REINSTALL ITEMS THAT WERE REMOVED. REMOVE SURFACE-APPLIED PROTECTION. C. CLEAN SUBSTRATES OF SUBSTANCES THAT COULD IMPAIR BOND OF PAINTS, INCLUDING DIRT, OIL, GREASE, AND INCOMPATIBLE PAINTS AND ENCAPSULANTS. 1. REMOVE INCOMPATIBLE PRIMERS AND REPRIME SUBSTRATE WITH COMPATIBLE PRIMERS AS REQUIRED TO PRODUCE PAINT SYSTEMS INDICATED. D. MASONRY SUBSTRATES: REMOVE EFFLORESCENCE AND CHALK. DO NOT PAINT SURFACES IF MOISTURE CONTENT OR ALKALINITY OF SURFACES OR MORTAR JOINTS EXCEEDS THAT PERMITTED IN MANUFACTURER'S WRITTEN INSTRUCTIONS. E. STEEL SUBSTRATES: REMOVE RUST AND LOOSE MILL SCALE. CLEAN USING METHODS RECOMMENDED IN WRITING BY PAINT MANUFACTURER BUT NOT LESS THAN THE FOLLOWING: 1. SSPC-SP 2, HAND TOOL CLEANING. 2. SSPC-SP 3, POWER TOOL CLEANING. 3. SSPC-SP 7/NACE NO. 4, BRUSH-OFF BLAST CLEANING. 4. SSPC-SP11, POWER TOOL CLEANING TO BARE METAL. F. SHOP-PRIMED STEEL SUBSTRATES: CLEAN FIELD WELDS, BOLTED CONNECTIONS, AND ABRADED AREAS OF SHOP PAINT, AND PAINT EXPOSED AREAS WITH THE SAME MATERIAL AS USED FOR SHOP PRIMING TO COMPLY WITH SSPC-PA 1 FOR TOUCHING UP SHOP-PRIMING. G. GALVANIZED-METAL SUBSTRATES: REMOVE GREASE AND OIL RESIDUE FROM GALVANIZED SHEET METAL BY MECHANICAL METHODS TO PRODUCE CLEAN, LIGHTLY ETCHED SURFACES THAT PROMOTE ADHESION OF SUBSEQUENTLY APPLIED PAINTS. H. COTTON OR CANVAS INSULATION COVERING SUBSTRATES: REMOVE DUST, DIRT, AND OTHER FOREIGN MATERIAL THAT MIGHT IMPAIR BOND OF PAINTS TO SUBSTRATES. 3.03 APPLICATION A. APPLY PAINTS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. 1. USE APPLICATORS AND TECHNIQUES SUITED FOR PAINT AND SUBSTRATE INDICATED. 2. PAINT SURFACES BEHIND MOVABLE ITEMS SAME AS SIMILAR EXPOSED SURFACES. BEFORE FINAL INSTALLATION, PAINT SURFACES BEHIND PERMANENTLY FIXED ITEMS WITH PRIME COAT ONLY. 3. PAINT FRONT AND BACKSIDES OF ACCESS PANELS, REMOVABLE OR HINGED COVERS, AND SIMILAR HINGED ITEMS TO MATCH EXPOSED SURFACES. 4. PAINT BOTH SIDES AND EDGES OF EXTERIOR DOORS AND ENTIRE EXPOSED SURFACE OF EXTERIOR DOOR FRAMES. 5. PAINT ENTIRE EXPOSED SURFACE OF WOOD OR METAL WINDOW FRAMES AND SASHES. 6. DO NOT PAINT OVER LABELS OF INDEPENDENT TESTING AGENCIES OR EQUIPMENT NAME, IDENTIFICATION, PERFORMANCE RATING, OR NOMENCLATURE PLATES. 7. PRIMERS SPECIFIED IN PAINTING SCHEDULES MAY BE OMITTED ON ITEMS THAT ARE FACTORY PRIMED OR FACTORY FINISHED IF ACCEPTABLE TO TOPCOAT MANUFACTURERS. B. TINT UNDERCOATS SAME COLOR AS TOPCOAT, BUT TINT EACH UNDERCOAT A LIGHTER SHADE TO FACILITATE IDENTIFICATION OF EACH COAT IF MULTIPLE COATS OF SAME MATERIAL ARE TO BE APPLIED. PROVIDE SUFFICIENT DIFFERENCE IN SHADE OF UNDERCOATS TO DISTINGUISH EACH SEPARATE COAT. C. IF UNDERCOATS OR OTHER CONDITIONS SHOW THROUGH TOPCOAT, APPLY ADDITIONAL COATS UNTIL CURED FILM HAS A UNIFORM PAINT FINISH, COLOR, AND APPEARANCE. D. APPLY PAINTS TO PRODUCE SURFACE FILMS WITHOUT CLOUDINESS, SPOTTING, HOLIDAYS, LAPS, BRUSH MARKS, ROLLER TRACKING, RUNS, SAGS, ROPINESS, OR OTHER SURFACE IMPERFECTIONS. CUT IN SHARP LINES AND COLOR BREAKS. 3.04 FIELD QUALITY CONTROL A. DRY FILM THICKNESS TESTING: OWNER MAY ENGAGE THE SERVICES OF A QUALIFIED TESTING AND INSPECTING AGENCY TO INSPECT AND TEST PAINT FOR DRY FILM THICKNESS. 1. CONTRACTOR SHALL TOUCH UP AND RESTORE PAINTED SURFACES DAMAGED BY TESTING. 2. IF TEST RESULTS SHOW THAT DRY FILM THICKNESS OF APPLIED PAINT DOES NOT COMPLY WITH PAINT MANUFACTURER'S WRITTEN RECOMMENDATIONS, CONTRACTOR SHALL PAY FOR TESTING AND APPLY ADDITIONAL COATS AS NEEDED TO PROVIDE DRY FILM THICKNESS THAT COMPLIES WITH PAINT MANUFACTURER'S WRITTEN RECOMMENDATIONS. 3.05 CLEANING AND PROTECTION A. AT THE END OF EACH WORKDAY, REMOVE RUBBISH, EMPTY CANS, RAGS, AND OTHER DISCARDED MATERIALS FROM PROJECT SITE. B. AFTER COMPLETING PAINT APPLICATION, CLEAN SPATTERED SURFACES. REMOVE SPATTERED PAINT BY WASHING, SCRAPING, OR OTHER METHODS. DO NOT SCRATCH OR DAMAGE ADJACENT FINISHED SURFACES. C. PROTECT WORK OF OTHER TRADES AGAINST DAMAGE FROM PAINT APPLICATION. CORRECT DAMAGE TO WORK OF OTHER TRADES BY CLEANING, REPAIRING, REPLACING, AND REFINISHING, AND LEAVE IN AN UNDAMAGED CONDITION. D. AT COMPLETION OF CONSTRUCTION ACTIVITIES OF OTHER TRADES, TOUCH UP AND RESTORE DAMAGED OR DEFACED PAINTED SURFACES. 3.06 EXTERIOR PAINT SCHEDULE A. EXTERIOR PORTLAND CEMENT PLASTER: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER EXTERIOR PLASTER SUBSTRATES: 1ST COAT: HIGH-PERFORMANCE ACRYLIC PRIMER. 1) DUNN-EDWARDS: ESPR00 EFF-STOP PREMIUM STUCCO PRIMER. 2) BENJAMIN MOORE: SUPER SPEC INTERIOR/EXTERIOR ACRYLIC HIGH BUILD PRIMER N068. 3) SHERWIN-WILLIAMS: S-W LOXON CONCRETE & MASONRY PRIMER SEALER A24W8300. 4) VISTA: 4600 UNIPRIME II ACRYLIC PRIMER. 2ND COAT AND 3RD COATS: FLAT ACRYLIC-LATEX PAINT FOR EXTERIOR APPLICATION. 1) DUNN-EDWARDS: EVSH10 EVERSHIELD VOC FLAT. 2) BENJAMIN MOORE: REGAL SELECT EXTERIOR HIGH-BUILD FLAT FINISH N400. 3) SHERWIN-WILLIAMS: S-W A-100 EXTERIOR LATEX FLAT A6 SERIES. 4) VISTA: 2800 ACRIGLO 100% ACRYLIC FLAT FINISH. B. CONCRETE UNIT MASONRY (SMOOTH): PROVIDE THE FOLLOWING FINISH SYSTEMS OVER EXTERIOR SMOOTH CONCRETE UNIT MASONRY SUBSTRATES: 1ST COAT: HIGH-PERFORMANCE ACRYLIC BLOCK FILLER. 1) DUNN-EDWARDS: SBPR00 BLOCFIL PREMIUM SMOOTH BLOCK FILLER. 2) BENJAMIN MOORE: SUPER SPEC MASONRY INTERIOR/EXTERIOR HI-BUILD BLOCK FILLER 206. 3) SHERWIN-WILLIAMS: S-W PREPRITE BLOCK FILLER B25W25 . 4) VISTA: 040 BLOCK KOTE ACRYLIC BLOCK FILLER. 2ND AND 3RD COATS: FLAT ACRYLIC-LATEX PAINT FOR EXTERIOR APPLICATION. 1) DUNN-EDWARDS: EVSH10 EVERSHIELD VOC FLAT. 2) BENJAMIN MOORE: REGAL SELECT EXTERIOR HIGH-BUILD FLAT FINISH N400. 3) SHERWIN-WILLIAMS: S-W A-100 EXTERIOR LATEX FLAT A6 SERIES. 4) VISTA: 2800 ACRIGLO 100% ACRYLIC FLAT FINISH. C. CONCRETE UNIT MASONRY (TEXTURED): PROVIDE THE FOLLOWING FINISH SYSTEMS OVER EXTERIOR TEXTURED CONCRETE UNIT MASONRY SUBSTRATES: 1ST COAT: HIGH-PERFORMANCE ACRYLIC BLOCK PRIMER. 1) DUNN-EDWARDS: ESPR00 EFF-STOP PREMIUM MASONRY PRIMER. 2) BENJAMIN MOORE: SUPER SPEC INTERIOR/EXTERIOR ACRYLIC HIGH BUILD PRIMER N068. 3) SHERWIN-WILLIAMS: LOXON CONCRETE & MASONRY PRIMER SEALER A24W8300. 4) VISTA: 4600 UNIPRIME II ACRYLIC PRIMER. 2ND AND 3RD COATS: FLAT ACRYLIC-LATEX PAINT FOR EXTERIOR APPLICATION. 1) DUNN-EDWARDS: EVSH10 EVERSHIELD ACRYLIC FLAT. 2) BENJAMIN MOORE: REGAL SELECT EXTERIOR HIGH-BUILD FLAT FINISH N400. 3) SHERWIN-WILLIAMS: S-W A-100 EXTERIOR LATEX FLAT A6 SERIES. 4) VISTA: 2800 ACRIGLO 100% ACRYLIC FLAT FINISH. D. CONCRETE UNIT MASONRY (INTEGRAL COLOR): PROVIDE THE FOLLOWING FINISH SYSTEMS OVER EXTERIOR INTEGRAL COLOR CONCRETE UNIT MASONRY SUBSTRATES: HIGH-PERFORMANCE WATER REPELLANT (10-YEAR MANUFACTURER WARRANTEE): 1) RAINGUARD: MICRO-SEAL SILANE/SILOXANE PENETRATING WATER REPELLENT. 2) PROSOCO: WEATHER SEAL SILOXANE WB CONCENTRATE. 3) SHERWIN-WILLIAMS: S-W LOXON 7% SILOXANE WATER REPELLENT A10T7. 4) MONOCHEM: MONOPOLE ME7 SILOXANE WATER REPELLENT. E. WOOD: PROVIDE THE FOLLOWING PAINT FINISH SYSTEMS OVER NEW EXTERIOR WOOD SUBSTRATES: 1ST COAT: ACRYLIC-LATEX-BASED EXTERIOR WOOD PRIMER. 1) DUNN-EDWARDS: EZPR00 EZ-PRIME PREMIUM EXTERIOR WOOD PRIMER. 2) BENJAMIN MOORE: FRESH START HIGH-HIDING ALL PURPOSE PRIMER 046. 3) SHERWIN-WILLIAMS: S-W EXTERIOR LATEX WOOD PRIMER B42W8041. 4) VISTA: 4200 TERMINATOR II ACRYLIC EPOXY PRIMER/STAIN BLOCKER. 2ND AND 3RD COATS: SEMI-GLOSS BLOCK-RESISTANT ACRYLIC-LATEX ENAMEL FOR INTERIOR APPLICATION. 1) DUNN-EDWARDS: EVSH50 EVERSHIELD ACRYLIC SEMI-GLOSS. 2) BENJAMIN MOORE: ULTRA SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL HP29. 3) SHERWIN-WILLIAMS: S-W SOLO 100% ACRYLIC INTERIOR/EXTERIOR SEMI-GLOSS A76 SERIES. 4) VISTA: 7000 ACRIGLO 100% ACRYLIC SEMI-GLOSS ENAMEL. F. STEEL: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER EXTERIOR STEEL SUBSTRATES. PRIMER IS NOT REQUIRED ON SHOP-PRIMED ITEMS. 1ST COAT: RUST-INHIBITIVE METAL PRIMER FOR EXTERIOR APPLICATION. 1) DUNN-EDWARDS: BRPR00 BLOC-RUST PREMIUM RUST PREVENTATIVE METAL PRIMER. 2) BENJAMIN MOORE: ULTRA SPEC HP ACRYLIC METAL PRIMER HP04. 3) SHERWIN-WILLIAMS: S-W PRO INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER, B66-310 SERIES. 4) VISTA: 9600 PROTEC ALKYD EMULSION ZERO VOC METAL PRIME. 2ND AND 3RD COATS: SEMI-GLOSS WATERBORNE ACRYLIC ENAMEL FOR EXTERIOR APPLICATION. 1) DUNN-EDWARDS: EVSH50 EVERSHIELD ACRYLIC SEMI-GLOSS. 2) BENJAMIN MOORE: ULTRA SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL HP29. 3) SHERWIN-WILLIAMS: S-W SOLO 100% ACRYLIC INTERIOR/EXTERIOR SEMI-GLOSS A76 SERIES. 4) VISTA: 7000 ACRIGLO 100% ACRYLIC SEMI-GLOSS. G. GALVANIZED METAL: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER EXTERIOR GALVANIZED-METAL SUBSTRATES: 1ST COAT: GALVANIZED METAL PRIMER FOR EXTERIOR APPLICATION. 1) DUNN-EDWARDS: UGPR00 ULTRA-GRIP PREMIUM ACRYLIC MULTI-PURPOSE PRIMER. 2) BENJAMIN MOORE: ULTRA SPEC HP ACRYLIC METAL PRIMER HP04. 3) SHERWIN-WILLIAMS: S-W PRO INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER, B66-310 SERIES. 4) VISTA: 4800 METAL PRO ACRYLIC PRIMER. 2ND AND 3RD COATS: SEMI-GLOSS WATERBORNE ACRYLIC ENAMEL FOR EXTERIOR APPLICATION. 1) DUNN-EDWARDS: EVSH50 EVERSHIELD ACRYLIC SEMI-GLOSS. 2) BENJAMIN MOORE: ULTRA SPEC HP ACRYLIC DTM SEMI-GLOSS ENAMEL HP29. 3) SHERWIN-WILLIAMS: S-W SOLO 100% ACRYLIC INTERIOR/EXTERIOR SEMI-GLOSS A76 SERIES. 4) VISTA: 7000 ACRIGLO 100% ACRYLIC SEMI-GLOSS. 3.07 INTERIOR PAINT SCHEDULE A. GYPSUM BOARD: PROVIDE THE FOLLOWING LOW ODOR/ZERO VOC FINISH SYSTEMS OVER INTERIOR GYPSUM BOARD SURFACES: 1ST COAT: LATEX-BASED PRIMER FOR INTERIOR APPLICATION. 1) DUNN-EDWARDS: UGSL00 ULTRA GRIP SELECT MULTI-SURFACE PRIMER. 2) BENJAMIN MOORE: ULTRA SPEC 500 INTERIOR LATEX PRIMER N534. 3) VISTA: 5001 V-PRO 5000 ZERO VOC PRIMER. 2ND AND 3RD COATS: FLAT BLOCK-RESISTANT ACRYLIC-LATEX ENAMEL FOR INTERIOR APPLICATION. 1) DUNN-EDWARDS: EVER10 EVEREST LOW ODOR/ZERO VOC FLAT. 2) BENJAMIN MOORE: ULTRA SPEC 500 INTERIOR LATEX FLAT N536. 3) VISTA: 5100 V-PRO 5000 FLAT. B. WOOD: PROVIDE THE FOLLOWING LOW ODOR/ZERO VOC FINISH SYSTEMS OVER NEW INTERIOR WOOD SUBSTRATES: 1ST COAT: ACRYLIC-LATEX-BASED INTERIOR WOOD PRIMER. 1) DUNN-EDWARDS: UGSL00 ULTRA GRIP SELECT MULTI-SURFACE PRIMER. 2) BENJAMIN MOORE: FRESH START MULTI-PURPOSE PRIMER N023. 3) VISTA: 4200 TERMINATOR II PRIMER. 2ND AND 3RD COATS: SEMI-GLOSS BLOCK-RESISTANT ACRYLIC-LATEX ENAMEL FOR INTERIOR APPLICATION. 1) DUNN-EDWARDS: EVER50 EVEREST 100 PERCENT ACRYLIC SEMI-GLOSS. 2) BENJAMIN MOORE: ULTRA SPEC 500 INTERIOR LATEX SEMI-GLOSS N540. 3) VISTA: 5400 V-PRO 5000 SEMI-GLOSS. C. CONCRETE UNIT MASONRY: PROVIDE THE FOLLOWING LOW ODOR/ZERO VOC FINISH SYSTEMS OVER SMOOTH CONCRETE UNIT MASONRY SUBSTRATES: 1ST COAT: ACRYLIC-LATEX-BASED INTERIOR BLOCK PRIMER. 1) DUNN-EDWARDS: UGSL00 ULTRA GRIP SELECT ACRYLIC MULTI-SURFACE PRIMER. 2) BENJAMIN MOORE: SUPER SPEC MASONRY INTERIOR/EXTERIOR ACRYLIC BLOCK FILLER 206. 3) VISTA: 040 BLOCK KOTE ACRYLIC BLOCK FILLER. 2ND AND 3RD COATS: FLAT ACRYLIC-LATEX PAINT FOR INTERIOR APPLICATION. 1) DUNN-EDWARDS: EVSH10 EVERSHIELD VOC FLAT. 2) BENJAMIN MOORE: ULTRA SPEC 500 INTERIOR LATEX FLAT N536. 3) VISTA: 5100 V-PRO 5000 FLAT. D. STEEL: PROVIDE THE FOLLOWING LOW ODOR/ZERO VOC FINISH SYSTEMS OVER INTERIOR STEEL SUBSTRATES: 1ST COAT: QUICK-DRYING RUST-INHIBITIVE LATEX-BASED METAL PRIMER. 1) DUNN-EDWARDS: UGPR00 ULTRA GRIP PREMIUM ACRYLIC MULTI-SURFACE PRIMER. 2) BENJAMIN MOORE: SUPER SPEC HP ACRYLIC METAL PRIMER P04. 3) VISTA: 9600 PROTEC ALKYD EMULSION ZERO VOC METAL PRIMER. 2ND AND 3RD COATS: SEMI-GLOSS BLOCK-RESISTANT ACRYLIC-LATEX ENAMEL FOR INTERIOR APPLICATION. 1) DUNN-EDWARDS: EVER50 EVEREST 100 PERCENT ACRYLIC SEMI-GLOSS. 2) BENJAMIN MOORE: ULTRA SPEC 500 INTERIOR LATEX SEMI-GLOSS N540. 3) VISTA: 5400 V-PRO 5000 SEMI-GLOSS. E. GALVANIZED METAL: PROVIDE THE FOLLOWING LOW ODOR/ZERO VOC FINISH SYSTEMS OVER INTERIOR GALVANIZED-METAL SUBSTRATES: 1ST COAT: ACRYLIC LATEX-BASED GALVANIZED METAL PRIMER. 1) DUNN-EDWARDS: UGPR00 ULTRA GRIP PREMIUM ACRYLIC MULTI-SURFACE PRIMER. 2) BENJAMIN MOORE: SUPER SPEC HP ACRYLIC METAL PRIMER P04. 3) VISTA: 4800 METAL PRO PRIMER. 2ND AND 3RD COATS: SEMI-GLOSS BLOCK-RESISTANT ACRYLIC-LATEX ENAMEL FOR INTERIOR APPLICATION. 1) DUNN-EDWARDS: EVER50 EVEREST 100 PERCENT ACRYLIC SEMI-GLOSS. 2) BENJAMIN MOORE: ULTRA SPEC 500 INTERIOR LATEX SEMI-GLOSS N540. 3) VISTA: 5400 V-PRO 5000 SEMI-GLOSS. END OF SECTION 6.26.25 1WALL SECTION 3/4" =1'-0" (E) +8'-0" B.O. ENTRY POP-OUT SOFFIT ±0'-0" MALL FLOOR FINISH (E) +16'-0" MALL COMMON CEILING MARKETING OFFICE MALL COMMON AREA 5' - 6 " 1' - 2 " 1' - 4 " (E ) 8 ' - 0 " V. I . F . (E) ENTRY POP-OUT FINISH TO REMAIN. PATCH AND REPAIR IF NEEDED. CLEAN TO LOOK "NEW" (N) ENTRY POP-OUT FINISH TO MATCH ADJACENT FINISH, COLOR: DARK GRAY (E) MALL WALL FINISH, PATCH AND REPAIR AFFECTED BY DEMO. (E) WALL TO REMAIN (E) OVERHANG CANOPY, AT MALL SIDE TO REMAIN (E) CEILING SOFFIT TO REMAIN (N) ENTRY POP-OUT FINISH TO MATCH ADJACENT FINISH PATCH AND REPAIR (E) GYP BD AS NEEDED, PAINT (N) STOREFRONT DOOR, SEE DOOR SCHEDULE (N) FLOOR TILE FINISH. BEDROSIANS: AREA 51 (24" X 24") CLAY MATTE STAGGERED PATTERN MALL (E) FLOOR FINISH (N.A.P.)TENANT (N) FLOOR FINISH LINE OF (E) ENTRY POP-OUT FINISH TO REMAIN.LINE OF (E) WALL FINISH, BEYOND 5"101 2" V.I.F. 9WALL SECTION 3/4" =1'-0" (E) +8'-0" B.O. ENTRY POP-OUT SOFFIT ±0'-0" MALL FLOOR FINISH (E) +16'-0" MALL COMMON CEILING T.O. CEILING +10'-0" LEASING OFFICE MALL COMMON AREA (E ) 6 ' - 7 " V. I . F . (E) MALL WALL FINISH, PATCH AND REPAIR AREA AFFECTED BY DEMO. (E) WALL TO REMAIN (E) OVERHANG CANOPY AT MALL SIDE TO REMAIN (E) CEILING SOFFIT. TO REMAIN PROTECT (E) STOREFRONT WINDOW TO REMAIN. (N) FLOOR TILE FINISH. BEDROSIANS: AREA 51 (24" X 24") CLAY MATTE STAGGERED PATTERN MALL (E) FLOOR FINISH (N.A.P.)TENANT (N) FLOOR FINISH LINE OF (E) ENTRY POP-OUT FINISH BEHIND LINE OF (E) WALL FINISH, BEYOND (E) MALL WALL FINISH TO REMAIN NOTE: G.C. TO VERIFY IN FIELD THE ACTUAL DIMENSION AND CONDITIONS OF ALL EXISTING. REMOVE (E) FLATFORM 9' - 5 " A601 9A (E) B.O. MALL ROOF DECK NOTE: G.C. TO VERIFY IN FIELD THE ACTUAL DIMENSION AND CONDITIONS OF ALL EXISTING. (E) B.O. MALL ROOF DECK WOOD JOISTS METAL DECK/CONC. FILL OPEN WEB STEEL JOISTS (AT 8'-0"MAX.) WOOD JOISTS METAL DECK/CONC. FILL OPEN WEB STEEL JOISTS (AT 8'-0" MAX.) FULL HEIGHT PARTITION PARTIAL HEIGHT PARTITION NOTE: 1. SEE TABLES A AND B WITHIN DETAIL 14/- FOR STUD AND DIAGONAL BRACE SIZE. 2. CONNECTION DETAILS ARE NOT APPLICABLE TO FIRE RATED PARTITIONS. NOTE: 1. SEE TABLES A AND B AT DETAIL 14 FOR STUD SIZE. 2. CONNECTION DETAILS ARE NOT APPLICABLE TO FIRE RATED PARTITIONS. 21 1 3 H H H H H H 3 3 4 5 6 5 3 3 3 L L L 14 ' - 6 " M A X . 14 ' - 6 " M A X . 14 ' - 6 " M A X . 8 10 9 11711 4 10 10 9 SLIP TRACK SLIP TRACK SLIP TRACK 13 METAL DECK/INSUL BD. H H 3 12 13 SLIP TRACK 13 CONC.INSUL. 13 METAL DECK/INSUL. BD. 3 L 14 ' - 6 " M A X . 12 10 8' MAX. 4TYPICAL INTERIOR NON-BEARING PARTITION DETAILS SCALE: NOT TO SCALE NOTES: 1. (2) - #12 WD. SCREWS AT 24" O.C. MAX., SPACED 2" APART. 2. 2x BLK'G. AT 24" O.C. WITH HANGER EA. END, FACE NAIL TYP. 3. (1) - 0.138" DIA. HILTI X-C (ICC-ESR #1752) WITH 1-1/4" EMBED. AT 16" O.C. 4. 3" x 9" x 20 GA. STL. STRAPS AT 24" O.C. WITH (1) - 0.138" DIA. HILTI X-C (ICC-ESR #1752) WITH 1-1/4" EMBED., IN (2) FLUTES MIN. 5. (2) - 0.138" DIA. HILTI X-C (ICC-ESR #1752) WITH 1-1/4" EMBED. AT 24" O.C. MAX. 6. 362S137-54 BLK'G AT 24" O.C. (8'-0" MAX. SPAN) WITH (2) - 0.138" DIA. HILTI X-C (ICC-ESR #1752) EA. END, SPACED 3" APART. 7. SAME AS 6, AT 4'-0" O.C. MAX. 8. 2x WD. BLK'G AT 4'-0" O.C. (STAGG.) WITH HANGER EA. END, FACE NAIL TYP. 9. (3) - #12 x 2" WD. SCREWS AT EA. BRACE, SPACED 2" APART. 10. DIAG. BRACE AT 4'-0" O.C. STAGG. IN EA. DIRECTION (SEE TABLE B), CUT FLANGE AND BEND WEB EA. END, WITH (3) - #12 S.M.S. AT EA. END TYP. 11. (3) - 0.138" DIA. HILTI X-C (ICC-ESR #1752), EA. BRACE, SPACED 3" APART. 12. 3" x 9" x 20 GA. STL. STRAPS AT 24" O.C. WITH (1) - #10 S.M.S. EA. IN (2) FLUTES MIN. 13. (2) - #10 S.M.S. AT 24" O.C. THRU TRACK. NOTES: 1. ALL WOOD STUDS SHALL BE MIN. DOUGLAS FIR-LARCH STUD GRADE. 2. BOTTOM TRACK AND TOP SLIP TRACK SHALL MATCH THE METAL STUD GAGE (20 GA. MIN. TYP., U.N.O.). 3.METAL STUDS: PER ICC ESR 4205, ASTM C754. MAX. HGT. ('H') BASED ON "COMPOSITE FRAMING" (GYP. BD. FULL HGT., BOTH SIDES, OR FLANGE BRACING), 10#/SF LIVE LOAD, AND L/120 DEFLECTION, U.N.O. (2) #12 S.M.S. AT 12" O.C. DETAIL B TABLE A - VERT. STUDS (NON-BEARING) WOOD STUDS MAX. HEIGHT (H) MIN. STUD SIZE 14'-0"2x4 AT 16" O.C. 21'-0"2x6 AT 16" O.C. METAL STUDS MAX. HEIGHT (H) MIN. STUD SIZE 16'-5"362S125-30 AT 16" O.C. 17'-5"400S125-30 AT 16" O.C. 21'-7"550S125-30 AT 16" O.C. 21'-8"600S125-30 AT 16" O.C. TABLE B - DIAGONAL BRACES MAX. LGT. (L) MIN. STUD SIZE 8'-0"362S or 400S125-30 8'-8"600S125-30 11'-5"PR. 400S125-30 (DET. B) 12'-3"PR. 600s125-30 (DET. B) DISCLAIMER: BY USING THESE GENERAL DESIGN GUIDELINES, CONTRACTOR ACCEPTS FULL RESPONSIBILITY. PROVIDE COMPLETE DESIGN CALCULATIONS AND DETAILS FOR ANY CONDITIONS NOT SHOWN, WET STAMPED AND SIGNED BY A CALIFORNIA LICENSED STRUCT'L ENGINEERING. 12TYPICAL STUD SIZES SCALE: NOT TO SCALE YY A601 9B A401 16 CONFERENCE ROOM OPEN OFFICES (E) B.O. MALL ROOF DECK T.O. CEILING +10'-0" NEW CEILING (ACT). SEE RCP PLAN A601 15 A601 17 (E) ACT CEILING GRID TO REMAIN, REPLACE NEW PANELS SEE RCP PLAN 3 5/8" X 20 GA. @ 16" O.C. DIAGONAL BRACING 1" DUAL INSUL. GLASS TYP. - 17B - 17C T.O. CEILING +10'-0" 13WALL SECTION 3/4" =1'-0" NEW 3 5/8" X 20 GA. @ 16" O.C. (E) ACT CEILING GRID TO REMAIN, REPLACE NEW PANELS SEE RCP PLAN T.O. STOREFRONT +8'-0" (E) ACT CEILING GRID TO REMAIN, REPLACE NEW PANELS SEE RCP PLAN 3"x3"x4"LG. x 20 GA. STL. CLIP 'L' WITH (2)-#10 S.M.S. EA. AT TRACK AND BRACES TYP. (+/- 800# SHEAR). MTL. STUD DIAG. BRACES AT 4'-0" O.C. MAX., STAGGERED TYP. SEE DET. 18/TABLE B. 14 ' - 6 " M A X . VE R I F Y H G T . I N F I E L D 5/8" GYP BD. FULL HEIGHT WHERE OCCURS, TYP. SEE PLAN FOR STUD SIZE/GA. 14'-6" MAX. HGT. LIMITED BY TOP CONNECTION LOADING! 12" MIN. BEARING 362T-162-33 BASE TRACK WITH SHOT PINS AT 16" O.C. MAX TYP., 'HILTI' X-C (OR EQ.)., 1-1/4" EMBED., (240# SHEAR). ICC ESR 1752. EXISTING CONC. SLAB 3-1/2" MINERAL WOOL SOUND BATT (WHERE OCCURS, SEE PLAN) FULL HGT. TYP., STC 49 ASM'BLY, RIVERBANK ACOUSTIC LAB (R.A.L.) TL-90-166 SUSP'D ACOUT. CL'G SYSTEM WITH SOUND BATT INSUL. OVER (WHERE OCCURS). SEE CL'G PLAN. A401 16 DIAG . B R A C E MAX . L G T . = ' L ' 4'-0" MAX. 4'-0" MAX. 4' - 0 " MA X . 4' - 0 " MA X . ST L . P U R L I N S D. TYP. BRACING PLAN VIEW 1/8" = 1'-0" MAX. LGT. = 'L' CORNER BRACE WITH (2)-#10 S.M.S. EA. END TYP. KICKER WITH SHOT PINS TYP. 17INTERIOR PARTITION (NON-RATED)1" = 1'-0" 3" x 9" x 20 GA. STL. STRAPS AT 24" O.C. WITH (1) - #10 S.M.S. EA. IN (2) FLUTES MIN. B. PARTITION PARALLEL TO DECKING (E) METAL DECK BEND 2" LEG WITH (1) 1/4" DIA. EXP. ANCHOR, 'HILTI' KB-TZ2 (OR EQ.)., 1-3/4" EMBED., (942# SHEAR EA.). ICC ESR 4266. 1 1 C. DIAGONAL KICKER BRACE A301 WALL SECTIONS AND PARTITION DETAILS A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 PC1 PC2 PC3 PC2 PC3 PC3 R1 R1 R1 R1 R1 R1 R1 R2 R2 R2 6.26.25 NOTES: DRAIN AND HOT PIPES UNDER LAVATORIES SHALL BE INSULATED TO PREVENT A PERSON WITHOUT SENSATION IN A WHEELCHAIR FROM BEING BURNED. USE 'TRUEBRO' HANDI-LAV GUARD INSULATION KIT. PROVIDE "INSTA-HOT" DEMAND-TYPE WATER HEATER FOR LAVATORY. SEE PLUMB. AND ELECT. DWGS. FOR EXACT LOCATION. FLOORING: LVT FLOORING BY: ARMSTRONG - RIBE: J7207 5TOILET ROOM ELEVATIONS 1/4" = 1'-0" WOMENMEN SIGNAGE GENERAL NOTES: 1. ROOM SIGN SHALL BE TEXT, BRAILLE CHARACTERS, AND PICTORIAL SYMBOLS (PICTOGRAMS). LETTERS AND NUMERALS SHALL BE RAISED 1/32" (O.08MM) UPPER CASE SANS-SERIF, AND 5/8" MIN. TO 2" MAX. HG. (BASED ON HGT. OF UPPERCASE 'I'). STROKE OF UPPERCASE 'I' SHALL BE 15% MAX. OF THE CHARACTER HGT. 2. BRAILLE SHALL BE CONTRACTED (GRADE 2). 3. THE TEXT, BRAILLE, AND PICTOGRAMS SHALL CONTRAST WITH THEIR BACKGROUND. ALL SIGN SURFACES SHALL HAVE A NON-GLARE FINISH. 4. ROOM SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR TYP. ROOM SIGNS SHALL CONTRAST WITH THE WALL FIN. (BACKGROUND). I.D. SIGNAGE ON LATCH SIDE OF DOOR SHALL BE 48" MIN. AT LOWEST BRAILLE CELLS, AND 60" MAX. AT HIGHEST LINE OF RAISED CHARACTERS. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT.CORRESPONDING GRADE II BRAILLE 1/4" THICK ACRYLIC PLASTIC. IMAGE AND LETTERS SHALL BE ENGRAVED (MIN. 1/32" DIST.) INTO PLAQUE SURFACE. SUB-SURFACE IMAGES SHALL BE CENTERED ON PLAQUE. DOOR SYMBOL, CENTERED AS SHOWN. THE SYMBOL SHALL CONTRAST WITH THE DOOR FIN. (BACKGROUND). 3' - 0 " 58 " M I N . T O 6 0 " M A X . EQ.EQ. ROOM SIGNS DOOR SYMBOLS 12" S I D E S 12 " D I A . 12 " D I A . MEN WOMEN ALL GENDER 4TOILET SIGNAGE N.T.S. 6" M I N . 60 " M A X . 48 " M I N . 9" 7"-9" 33 " M I N . 36 " M A X . 24" MIN. ELEVATION ELEVATION 1'- 7 " MI N . A B 1 2 5 9 3 SCHLUTER DILEX-AHKA BASE FINISH: SATIN ANODIZED ALUMINUM ELEVATION ELEVATIONDC 12"x 24" DREAMSTONE AZTEC ONYX BIANCO MATTE PORCELAIN TILE BY: TILEBAR 33 " M I N . 36 " M A X . DEMAND-TYPE WATER HEATER (SEE PLUMB. AND ELECT.) 3 9 2 1 4 6 5 30 " 12" MIN. 24"LC 17"-18" 12 19 " 40 " 11 12"x 24" DREAMSTONE AZTEC ONYX BIANCO MATTE PORCELAIN TILE BY: TILEBAR 13 2' - 1 0 " TYP. 40 " M A X . -- 8 -- 6A TYP. 8 6 4 4'- 0 " TI L E 8' - 0 " T. O . C E I L I N G 2" 3" 13 8' - 0 " T Y P . PRIME AND PAINT WALLS & CEILING, (2) COATS OF SEMI-GLOSS ENAMEL, COLOR: DEC6212 CRISP MUSLIN IDENTIFICATION SYMBOL ON OUTSIDE OF DOOR TYP. SEE DETAIL 4/- 58 " M I N . T O 6 0 " M A X . 7 40 " M I N . 4' - 0 " M A X . 3" X 24" DREAMSTONE AZTEC ONYX BIANCO POLISHED PORCELAIN BULLNOSE SINGLE ACCOMMODATION TOILET ROOM GENERAL NOTES 1. EACH TOILET ROOM ENTRY DOOR SHALL HAVE A PRIVACY LATCH. 2. WALLS SHALL BE SMOOTH, HARD, AND NON-ABSORBENT TO 48" IN HEIGHT, AND NOT ADVERSELY AFFECTED BY MOISTURE ALL AROUND TYP. 3. FLOOR SURFACES SHALL BE SMOOTH, HARD, AND NON-ABSORBENT, EXTENDING UPWARD A MIN. OF 6" ONTO WALLS ALL AROUND TYP. 4. FLUSH HANDLE SHALL BE ON WIDE SIDE OF FIXTURE WITH NO MORE THAN 5 LBS MAX. TO OPERATE. 5. INTERIOR DIMENSIONS SHALL INCLUDE A CLEAR FLOOR SPACE OF AT LEAST 60" IN DIA. OR A T-SHAPED CLEAR SPACE. DOOR MAY ENCROACH INTO THIS REQUIRED CLEAR SPACE BY 12" MAX. 6. GRAB BARS SHALL BE MOUNTED AT +33" A.F.F. MAX. TYP. (36" MAX. AT REAR ONLY TO CLEAR TANK TYPE TOILETS). MINIMAL GRAB BAR STRUCTURAL STRENGTH SHALL SUPPORT A 250 LB. POINT LOAD. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. 7. TOILET PAPER DISPENSER SHALL BE MOUNTED AT +19" A.F.F. TO BOTTOM OF ROLL, AND SHALL ALLOW CONTINUOUS PAPER FLOW (DOES NOT CONTROL DELIVERY). 8. INSULATE ALL LAVATORY & HAND SINK EXPOSED DRAINS AND HOT WATER PIPING BELOW FIXTURES. 9. PROVIDE WALL BUMPERS/STOPS AT ALL POINTS OF DOOR IMPACT. 10. PLUMBING FIXTURES SHALL MEET THE FOLLOWING STANDARDS: WATER CLOSET AT 1.28 GALLONS PER FLUSH MAXIMUM. LAVATORY FAUCETS AT 0.5 GPM MAX. METERING FAUCET SHALL REMAIN OPEN FOR 10 SECONDS MIN. 11. PROVIDE "INSTA-HOT" DEMAND HOT WATER FOR LAVATORY. SEE PLUMB. AND ELECT. DWGS. FOR EXACT LOCATION. 1ENLARGED ALL-GENDER TOILET PLAN 1/2" = 1'-0" 36" LG. GRAB BAR, +33" MAX. A.F.F. TYP., +36" TO CLR. TANK TOILET (PROVIDE BLK'G, SEE DETAIL 7), BY: KOHLER - TRADITIONAL 36" GRAB BARK (K-10544-BL), FINISH: MATTE BLACK COAT HOOK, +40"MIN. TO 48"MAX. A.F.F. TO TOP, AND CENTERED ON DOOR, BY: POTTERY BARN - LINDEN HOOK, FINISH: TUMBLED BRASS PAPER TOWEL DISPENSER, SURFACE MOUNTED, +40" MAX. A.F.F TO OPERABLE PART OF FIXTURE, BY: AMERICAN SPECIALTIES FINISH: STAINLESS STEEL BLACK TOILET SEAT COVER DISPENSER, SURFACE MOUNTED, +30" A.F.F. TO TOP BY: AMERICAN SPECIALTIES (MODEL:#0477-SM ) FINISH: MATTE BLACK ALUMINUM TRANSITION STRIP TYP. 1 2 3 4 5 6 7 8 9 SUBMIT SHOP DW'GS FOR ALL TOILET ROOM ACCESSORIES 17 " M I N . 18 " M A X . 5'- 0 " M I N . CL E A R F L O O R S P A C E CL 7 MIN. 9" MAX.1" CLR. 2'- 0 " 1'-0" MAX. 30X48 4'-8" MIN. CLEAR FLOOR SPACE 60 " 60" 8' - 7 " 8'-0" 2'-0" MIN. 4'-0" MIN. MANEUVER SPAVE 60" DIA. SPACE (N.T.S.) 3SINGLE TOILET GENERAL NOTES NO SCALE TOILET KEYNOTES: B A D C A401 5 5'-0" DIA. MIN. CLEARANCE 8 6 4 2 3 9 7 10 10 CL MIRROR 24"W x 36"H, +40" A.F.F. TO BASE AND CENTERED OVER LAVATORY BY: HERMITAGE BATH - MODEL: HBSM-2436MB FINISH: MATTE BLACK ADA COMPLAINT SINK BY: KOHLER - 21-3/4" RECTANGULAR PEDESTAL BATHROOM SINK (K-77767-1), +34" A.F.F. TO RIM. SEE DETAIL 10 11 42" LG. GRAB BAR, +33" MAX. A.F.F. TYP (PROVIDE BLOCKING, SEE DETAIL 7, BY: KOHLER - TRADITIONAL 42" GRAB BAR (K-10545), FINISH: MATTE BLACK SINGLE TOILET TISSUE HOLDER, SURFACE MOUNTED, +19" A.F.F. MIN. TO BOTTOM OF ROLL, 7" MIN. TO 9" MAX. ON CENTER TO FRONT OF TOILET, BY: KOHLER - PIVOTING TOILET PAPER HOLDER (K-27397), FINISH: MATTE BLACK TANK WATER CLOSET, +17" MIN. TO 19" MAX. TO TOP OF SEAT, BY KOHLER - TWO-PIECE ELONGATED TOILET, 1.28 GPF (K-25087) 11 12 SOAP DISPENSER, SURFACE MOUNTED BY: AMERICAN SPECIALTIES (MODEL:#0345) FINISH: MATTE BLACK 12 1' - 0 " MI N . 2'- 0 " MI N . FAUCET BY: KOHLER - SINGLE-HANDLE BATHROOM SINK FAUCET, 1.0 GPM (K-28126-4K) , FINISH: MATTE BLACK M GRAB BARTRADITIONALK-10545 GRAB BARTRADITIONALK-10544 BATHROOM SINKMODERNLIFEK-77767-1 15 13 EXISTING ELECTRICAL PANEL AND SUBMETER TO REMAIN 13 10LAVATORY DETAIL 1 1/2" = 1'-0" A.F.F. SINK VANITY (SEE PLUMB.). MIRROR, SEE SIZE AND MOUNTING HT. AT TOILET NOTES. INSULATE HOT WATER AND DRAIN PIPES WITH 'TRUEBRO' LAV GUARD 2 COVERS TYP. INSTANTANEOUS HEATER, WALL MOUNTED (SEE PLUMB.). NOTE: CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF THE DEMAND WATER HEATER AND DUPLEX OUTLET WITH ELECT. AND PLUMB. 27 " C L R . . KN E E S P . 8" MIN. 17" MIN. 29 " M I N . 34 " M A X . 6" MAX. 9" C L R . TO E S P . WALL TILE AT 4'-0" AFF. (BEYOND) TYP. SUSPENDED ACOUSTIC CEILING SYSTEM FROM STRUCTURE ABOVE AS FOLLOWS: FROM WOOD STRUCTURE: #10 CLOSED EYE SCREW. FROM STEEL PURLINS: 'HILTI' CC27/DN22 COMBINATION CEILING CLIPS/SHOT PINS (ICC ESR #2184, L.A.R.R. #25651) OR EQ., OR CLAMP ON 'UNISTRUT' CHANNELS AT 4'-0" O.C. PARALLEL WITH MAIN RUNNERS BELOW. FROM STEEL BAR JOISTS: TIE THRU BOTTOM FLANGES. FROM CONCRETE STEEL DECK OR CONCRETE DECK: 'HILTI' TB 27 S12 (ICC ESR #2184, L.A.R.R. #25651) OR EQ. 12 GA. VERTICAL WIRE HANGERS AT 4'-0" O.C. MAX. EA. WAY TYP. CEILING TILES, TYP. COMPRES. STRUT 4'-0" T Y P . 45° 2'- 0 " TYPI C A L 4 PL A C E S 12 GA. WIRE SPLAYED IN FOUR DIRECTIONS, 90° APART, AT 12'-0" O.C. MAX. EA. WAY TYP. 1/2" EMT: 4'-0" MAX. HGT. 3/4" : 5'-2" 1" : 6'-6" 1 1/4" : 8'-6" 1 1/2" : 10'-0" PAIR 1 5/8" x 25 GA. STUDS BACK-TO-BACK: 10'-0" MAX. PAIR 2 1/2" x 25 GA. STUDS BACK-TO-BACK: 15'-0" MAX. SUSPENDED ACOUSTICAL CEILING SYSTEM, 'DONN' DX (OR EQ.) TYP., U.N.O. (ICC ESR-#1222, L.A.R.R. #25764). SUSPENDED CEILING DETAIL STRUT DETAIL 2'-0 " CEILING SUSPENSION NOTES HANGER ATTACHMENT DEVICES SHALL BE AN APPROVED TYPE. SUSPENSION WIRES SHALL NOT BE SMALLER THAN NO. 12 GAUGE SPACED AT 4'-0" O.C. ALONG EACH MAIN RUNNER. EACH WIRE SHALL BE ATTACHED TO THE CEILING MEMBER AND THE SUPPORT ABOVE WITH A MINIMUM OF THREE TURNS. CONNECTION DEVICES AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. WIRES SHALL NOT HANG MORE THAN 1 IN 6 OUT OF PLUM, UNLESS COUNTERSLOPING WIRES ARE PROVIDED. A TRAPEZE SHALL BE USED WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. THE TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER SHALL BE INDEPENDENTLY SUPPORTED A MAXIMUM OF 8" FROM THE WALL OR CEILING WITH NO. 12 GAUGE WIRE. HORIZONTAL RESTRAINTS SHALL BE EFFECTED BY FOUR NO. 12 GAUGE WIRES SECURED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT TO EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING. A STRUT FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED UP AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12'-0" ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6'-0" FROM EACH WALL. ATTACHMENT OF THE RESTRAINT WIRES SHALL BE ADEQUATE FOR THE LOAD IMPOSED. LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM 0F 6" FROM ALL HORIZONTAL PIPING OR DUCTWORK THAT IS NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD WHICHEVER IS GREATER, WITH A SAFETY FACTOR OF 2. PERIMETER MEMBERS SHALL BE CONSIDERED AS AESTHETIC CLOSURES WITH NO STRUCTURAL VALUE. ENDS OF MAIN RUNNERS AND CROSS RUNNERS SHALL BE TIED TOGETHER TO PREVENT THEIR SPREADING. MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED AT TWO ADJACENT WALLS WITH CLEARANCE BETWEEN THE WALL AND RUNNERS MAINTAINED AT THE OTHER TWO WALLS. HEAVY DUTY CEILING SYSTEMS (CATEGORY D) SHALL BE USED FOR THE SUPPORT OF LIGHT FIXTURES. ALL LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED CEILING SYSTEM. THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF 100% OF THE LIGHTING FIXTURE WEIGHT ACTING IN ANY DIRECTION. WHEN INTERMEDIATE SYSTEMS ARE USED, NO. 12. GAUGE HANGER WIRES SHALL BE ATTACHED TO THE GRID MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE. TANDEM FIXTURES MAY UTILIZE COMMON WIRES. WHEN HEAVY DUTY SYSTEMS ARE USED, SUPPLEMENTAL HANGERS ARE NOT REQUIRED IF A 48" MODULAR PATTERN IS FOLLOWED. LIGHTING FIXTURES WEIGHING LESS THAN 56 POUNDS SHALL HAVE, IN ADDITION TO THE REQUIREMENTS ABOVE, TWO NO. 12 GAUGE HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. LIGHTING FIXTURES WEIGHING 56 POUNDS OR MORE SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. PENDANT HUNG LIGHTING FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE USING NO. 9 GAUGE WIRES OR APPROVED ALTERNATE SUPPORT WITHOUT USING THE CEILING SYSTEM FOR DIRECT SUPPORT. CEILING MOUNTED AIR TERMINALS OR SERVICES WEIGHING LESS THAN 20 POUNDS SHALL BE POSITIVELY ATTACHED TO THE MAIN RUNNERS OR CROSS RUNNERS WITH THE SAME CARRYING CAPACITY AS MAIN RUNNERS. SERVICES WEIGHING 20 POUNDS BUT LESS THAN 56 POUNDS SHALL HAVE, IN ADDITION TO THE ABOVE, TWO NO. 12 GAUGE HANGERS CONNECTED FROM THE TERMINAL OR SERVICE TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. SERVICE WEIGHING MORE THAN 56 POUNDS SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS, SHOW A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN AL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSION EVERY STRUCTURE, AND PORTION THEREOF, INCLUDING NONSTRUCTURAL COMPONENTS THAT ARE PERMANENTLY ATTACHED TO STRUCTURES AND THEIR SUPPORTS AND ATTACHMENTS, SHALL BE DESIGNED AND CONSTRUCTED TO RESIST THE EFFECTS OF EARTHQUAKE MOTIONS. THE SEISMIC DESIGN CATEGORY FOR A STRUCTURE IS PERMITTED TO BE DETERMINED IN ACCORDANCE WITH SECTION 1613 OR ASCE 7. ALL PARTITIONS SHALL BE BRACED INDEPENDENTLY FROM THE CEILING SYSTEM. 1" GAP MIN. TYP. TEE FACE SLEEVE TYP. FASTENERS CROSS TEE TYP. MAIN TEE, FIELD CUT AS REQ'D. LAY-IN CL'G TILE TYP. NOTE: PROVIDE SEISMIC JOINT AT MAIN AND CROSS-RUNNERS AS REQ'D TO DIVIDE CL'G INTO 2,500 SQ. FT. MAX. ZONES, LENGTH/WIDTH RATIO OF 1:4 MAX. 4-WAY SEISMIC JOINT CLIP, 'DONN' DH4 TYP. L.A.R.R. #25764 (OR EQ.) SPLICE CAP CRIMPED ONE SIDE TO ALLOW MOVEMENT ONLY ON OPPOSITE END 13SUSPENDED CEILING TILE DETAIL NOT SCALE 19CEILING SEISMIC JOINT DETAIL 3" = 1'-0" 16ACOUSTICAL CEILING PERIMETER 3" = 1'-0" 12"X24" DREAMSTONE AZTEC ONYX BIANCO MATTE PORCELAIN TILE BY: TILEBAR (E) 5/8" M/R GYP. BOARD 4'-5" A.F.F. 8TILE TRANSITION DETAIL 3" = 1'-0" 1 1/2" 5/8" M/R GYPSUM BOARD TYP. 3/16" THK. S.S. MOUNTING FLANGE AND ESCUTCHEON TYP. 1-1/2"Ø S.S. GRAB BAR, SATIN FIN., 'BOBRICK' B-6106 (OR. EQ.). TYP. (3)-1/4"Ø LAG BOLTS WITH 3" MIN. PENETRATION TO 4 x 4 BLOCKING. NOTE: WHERE A TANK-TYPE TOILET OBSTRUCTS PLACEMENT OF THE REAR GRAB BAR AT 33", THE GRAB BARS MAY BE INSTALLED UP TO 36" MAX. A.F.F. 4 x 4 BLOCKING BETWEEN 18 GA. MTL. STUDS WITH (2)-#12 x 2" R.H.W.S EA. END TYP. 33" MIN. TO 36" MAX. A.F.F. 7GRAB BAR BLOCKING 3" = 1'-0" NOTE: PER ESR-1222 REPORT, SUSPENDED CEILINGS THAT ARE PART OF BUILDING STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORIES D, E AND F MUST BE SUBJECT TO PERIODIC SPECIAL INSPECTIONS DURING THE INSTALLATION OF SUSPENDED CEILING SYSTEMS AND THEIR ANCHORAGE. THE SPECIAL INSPECTOR MUST VERIFY THAT THE CEILING SYSTEMS IS AS DESCRIBED IN THIS REPORT AND COMPLIES WITH THE INSTALLATION INSTRUCTIONS IN THIS REPORT AND WITH THE APPROVED CONSTRUCTION DOCUMENTS. 17WIRE HANGERS ATTACHMENT DETAIL 1-1/2" = 1-0" VERTICAL WIRE CONNECTION BRACING WIRE CONNECTION CONCRETE FRAMING OR CONCRETE FILLED METAL DECK CONNECTION NOTES: 1. POST INSTALLED ANCHORS (WEDGE BOLTS, SCREW ANCHORS, ETC) SHALL BE ICC APPROVED FOR SEISMIC DESIGN CATEGORY 'E'. SHOT PINS INTO CONCRETE SHALL NOT BE USED TO SUPPORT BRACING WIRES. 18WIRE HANGERS ATTACHMENT DETAIL 1-1/2" = 1-0" VERTICAL WIRE CONNECTION BRACING WIRE CONNECTION METAL STUD FRAMING CONNECTION NOTES: 1. POST INSTALLED ANCHORS (WEDGE BOLTS, SCREW ANCHORS, ETC) SHALL BE ICC APPROVED FOR SEISMIC DESIGN CATEGORY 'E'. SHOT PINS INTO CONCRETE SHALL NOT BE USED TO SUPPORT BRACING WIRES. 2. DO NOT HANG FROM METAL DECK UNLESS JUSTIFIED BY STRUCTURAL ENGINEER CALCULATIONS. (E) WALL TO BE PAINTED. PATCH AND REPAIR IF NEEDED. TILE ADHESIVE OR THIN SET MORTAR PER MANUFACTURER'S INSTRUCTION. 3" X 24" DREAMSTONE AZTEC ONYX BIANCO POLISHED PORCELAIN BULLNOSE WALL FINISH 1/4 LENGTH OF RUNNER (8" MAX.) 12 GA. HANGER WIRE AT 4'-0" x 4'-0" O.C. MAX. WITH MIN. (4) TURNS IN 1-1/2" TYP. MAIN OR CROSS RUNNER, POP-RIVET TO WALL ANGLE TYP. LAY-IN CL'G TILE TYP. 7/8" x 7/8" WALL ANGLE, SCREW TO EVERY OTHER STUD WITH #8 x 1-1/4" PANHEAD S.M.S. TYP. INTERIOR FACE OF WALL TYP. 1 6 1/4 LENGTH OF RUNNER (8" MAX.)'DONN' ACM7 SLIDE CLIP (OR EQ.) ICC ESR #1222, LA RR #25764, SCREW TO WALL ANGLE TYP. MAIN OR CROSS RUNNER IN SLIDE CLIP TYP. LAY-IN CL'G TILE TYP. 7/8" x 7/8" WALL ANGLE, SCREW TO EVERY OTHER STUD WITH #8 x 1-1/4" PANHEAD S.M.S. TYP. 1 63/4" NOTE: PROVIDE SLIDE JOINT AT TWO ADJ. SIDE WALLS EA. ROOM OR SPACE TYP. FIXED JOINT SLIDE JOINT MA X . MA X . CROSS RUNNER COMPRES. STRUT AND (4)-12 GA. LAT. BRACING WIRES SPLAYED 90 DEG. APART, TYP. AT 12'-0" O.C. MAX. EA. WAY MAIN RUNNERS AT 4'-0" O.C. MAX., TYP. 12 GA. GALV.WIRE HANGERS AT 4'-0" O.C. MAX. TYP. UP TO STRUCT. ABOVE, TYP. ACOUSTIC TILE PANELS, TYP. CONT. ALUM. EDGE ANGLE 5/8" GYP. BD., TYP. 6'-0" MAX. 6" MAX. 6" 6TYPICAL BASE DETAILS 6" = 1'-0" MOUNT ON WALL ON STRIKE SIDE OF DOOR FRAME, OR NEAREST ADJACENT WALL, ON RIGHT AT PAIR, 60" A.F.F. TYP. EXIT 6" x 4" HG. MATTE ACRYLIC, "WHITE" TEXT ON "RED" BACKGROUND, TYPEFACE: HELVETICA, 1" HIGH. AT ALL GRADE LEVEL EXTERIOR EXIT DOORS TYP.A 11DISABLED EXIT SIGNAGE 6" = 1'-0" 48 " M I N . 60 " M A X . SCHLUTER-DILEX-AHKAA TILEBAR 12X24 MATTE TILE TILE ADHESIVE OR THIN SET MORTAR (E) WALL, PATCH AND REPAIR IF NEEDED SCHLUTER DILEX-AHKA COVE-SHAPED W/ 3/8" RADIUS, ALUM. BRUSH FLOOR FINISH VINYL BASEB 4" JOHNSONITE VINYL BASE COLOR: 22 PEARL (BEIGE) (THROUGHOUT) (@ RESTROOM) A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 A401 ENLARGED TOILET PLAN, INT. ELEVATIONS, SECTIONS & DETAILS PC1 PC1 R1 R1 R1 R1 PC1 R1 R1 R1 R1 R1 R2.1 R1 R2.1 6.26.25 DOOR GENERAL NOTES DOOR TYPE 'A': MAIN ENTRY 3'-0" x 8'-0" x 1-3/4" FRAMELESS DOOR DISABLED DECAL A DOOR AND FRAME SCHEDULE DOOR DATA FRAME DETAILS REMARKS DOOR TYPE ROOM NAME HGT. WIDTH THKN. MAT'L MAT'L FIN. HEAD JAMB SILL D101 A MAIN ENTRY 8'-0" 3'-0"1-3/4" AL/GL AL ANOD. 9A/A601 --9C/A601 D102 B MANAGER'S OFFICE 8'-0"1-3/4" AL/GL AL ANOD. 13A/A601 16/A601 13C/A601 D105 B CONFERENCE ROOM 8'-0"AL/GL AL ANOD. 13A/A601 16/A601 13C/A601 C TOILET (E) 7'-0" (E) 3'-0"-- PAINT ------ D104 LEGEND: AL/GLALUMINUM/GLASS AL ALUMINUM ANOD. ANODIZED FACT. FACTORY FINISH HM HOLLOW METAL PM PRESSED METAL MTL METAL SC SOLID CORE T TEMPERED STOREFRONT INFORMATION: MANUFACTURER: 'KAWNEER 451 SERIES <OR> 'U.S. ALUMINUM' SERIES 451 <OR> 'ARCADIA' ASL451 FINISH: "CLEAR" ANODIZED ALUMINUM SEE SHEET A203 FOR EXTERIOR DOOR AND FRAME FINISH PAINTING. SEE SHEET A203 FOR INTERIOR DOOR AND FINISH PAINTING. SEE SHEET A203 FOR PAINTING SPEC. LABEL HDWR. SET 01 02 02 03 -- -- -- 3'-0" 3'-0"1-3/4" 1-3/4" MAIN ENTRY --RELOCATE DOOR - APPLY NEW PAINT GC TO VERIFY DOOR & HARDWARE CONDITION IS REUSABLE IF NOT REPLACE WITH NEW DOOR GENERAL NOTES: THE CONTRACTOR SHALL PROVIDE ALL NECESSARY LABOR, PARTS, AND SUPPORT PRODUCTS FOR A COMPLETE DOOR INSTALLATION. CONTRACTOR SHALL VERIFY ALL OPENING DIMENSIONS BEFORE FABRICATION AND INDICATE MEASUREMENTS ON DOOR AND FRAME SHOP DRAWINGS. SUBMIT DOOR AND HARDWARE SHOP DW'GS TO THE ARCHITECT FOR REVIEW. CONTRACTOR TO PROVIDE TEMPORARY CORES FOR ALL LOCKING DOORS, AND SEPARATE KEY FOR EACH TENANT SUITE, AND COMMON AREA DOORS. ALL DOORS SHALL HAVE A MINIMUM DOOR SIZE OF 36" AND A CLEAR OPENING WIDTH OF 34" WITH DOOR IN 90 DEGRESS OPEN POSITION. EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING AN OCCUPANT OF LOAD OF 50 OR MORE. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. OR, AT EACH MAIN EXIT DOOR IN GROUP A (300 OCC. OR LESS), B, F, M, OR S OCCUPANCIES, ATTACH A READILY VISIBLE, DURABLE SIGN STATING: "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". THE SIGN SHALL BE IN 1" HIGH LETTERS ON A CONTRASTING BACKGROUND. THE LOCKING DEVICE MUST BE READILY DISTINGUISHABLE AS LOCKED. MANUALLY OPERATED EDGE- OR SURFACE-MOUNTED FLUSH BOLTS AND SURFACE BOLTS ARE PROHIBITED AT EXIT DOORS. EXIT DOORS HAVING AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOOR KNOB OR SURFACE MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. EXTERIOR DOORS SHALL RECEIVE DEAD BOLTS AND DEAD LOCKING LATCHES. STRAIGHT DEAD BOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8". CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHEN THE CYLINDER PROJECTS FROM THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. DOOR HINGES SHALL HAVE NON-REMOVABLE PINS. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM THE POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. ALL DOOR HARDWARE SHALL BE MOUNTED FROM 30" TO 44" ABOVE THE FLOOR AND SHALL BE OPERABLE BY A SINGLE EFFORT WITH NO GRASPING OR WRIST MOVEMENT (I.E.: LEVERS, PUSH-PULLS, OR PANIC HARDWARE). THE ALLOWABLE CLOSER PRESSURE SHALL NOT EXCEED 5 POUNDS FOR INTERIOR DOORS, 5 POUNDS FOR EXTERIOR DOORS, AND 15 POUNDS FOR FIRE DOORS WITH PANIC HARDWARE. ALL DOOR HANDLE HARDWARE SHALL BE DISABLED ACCESSIBLE LEVER TYPE (SCHLAGE "ATHENS" STYLE OR EQ.) WITH 626 SATIN STAINLESS FINISH, U.N.O. PROVIDE INTERNATIONAL MEN'S AND WOMEN'S SYMBOLS (TRIANGLE OR CIRCLE) ON ALL DOORS TO TOILET ROOMS. SEE DETAIL 18 FOR SIGNS AT DOORS TO MEN'S AND WOMENS' SANITARY FACILITIES. DOOR AND FRAME SPECIFICATIONS: ON SITE STORAGE, INSTALLATION, AND ANCHORAGE FOR METAL DOORS AND FRAMES SHALL COMPLY WITH NAAMM STANDARD HMMA 840. FIRE-RATED DOOR ASSEMBLIES SHALL COMPLY WITH NFPA 80, FOR FIRE PROTECTION RATINGS INDICATED, BASED ON TESTING AT POSITIVE PRESSURE ACCORDING TO NFPA 252. CONTRACTOR TO COORD. POWERED HARDWARE WITH MANUF. REQ'MTS AND ELECT. DW'GS. CONTRACTOR TO COORD. FIRE/SMOKE DETECTOR RELEASE HARDWARE WITH DESIGN/BUILD FIRE ALARM SYSTEM (WHERE PROVIDED). HOLLOW METAL (HM) DOORS SHALL BE 18 GA., AND PRESSED METAL (PM) FRAMES SHALL BE 16 GA. MIN. TYP., U.N.O. ALL PRESSED METAL (PM) FRAMES SHALL HAVE WELDED JOINTS FILLED AND GROUND SMOOTH TYP., U.N.O. ALL PRESSED METAL (PM) FRAMES IN MASONRY WALLS SHALL BE SOLID GROUTED TYP., U.N.O. STEEL DOORS AND FRAMES SHALL BE SHOP PRIMED WITH RED OXIDE TYP., U.N.O. SOLID CORE (SC) WOOD DOORS AND FRAMES SHALL BE EITHER GLUED WOOD STAVE, OR STRUCTURAL COMPOSITE LUMBER CORES PER WDMA I.S. 10. AT PAINTED DOORS, SURFACE SHALL BE PREMIUM GRADE, PAINT GRADE BIRCH. AT STAINED AND SEALED DOORS, SURFACE SHALL BE PREMIUM GRADE WITH AA FACES, SELECT WHITE BIRCH, ROTARY CUT, BOOK MATCHED VENEER, U.N.O. ALIGN DOOR ANDS FRAMES PLUMB AND SQUARE TO WITH 1/16" TOLERANCE MAX., SECURELY FASTENED IN PLACE TYP. ALL DOOR HARDWARE TO COMPLY WITH ANSI/BHMA A156 SERIES STANDARDS. 6DOOR TYPES 3' - 0 " DOOR TYPE 'C': TOILET ROOM 3'-0" x 7'-0" x 1-3/4" (EXISTING OR NEW) 5' - 0 " C DISABLED SIGNAGE HARDWARE SET #01: SINGLE MAIN ENTRY DOOR PER MANUFACTURER 1 DISABLED DECAL SYMBOL HARDWARE SET #02: SINGLE DOOR 1 TOP, MIDDLE AND BOTTOM OFFSET PIVOTS, BY STOREFRONT FABRICATOR, FINISH: SATIN STAINLESS. 1 CONCEALED CLOSER, BY STOREFRONT FABRICATOR. 1 PINKYS LOCK WITH LEVER IN BLACK. 1 DEADLOCK, 'ADAMSRITE' MS-1850, WITH "EXIT" INDICATOR, KEY CYLINDER WITH CYLINDER GUARD, FINISH: SATIN STAINLESS. 1 THRESHOLD, 36" x 4" WIDE MIN., BY STOREFRONT FABRICATOR, FINISH: "CLEAR" ANODIZED ALUM. (EXISTING RESTROOM HARDWARE, GC TO CONFIRM IF COMPLIANT IF NOT REPLACE) HARDWARE SET #03: SINGLE TOILET ROOM DOOR 3 HINGES: 'STANLEY' FBB SERIES, 4-1/2", STD. WEIGHT, N.R.P., FINISH: PAINT. 1 LOCKSET: 'SCHLAGE' ND-SERIES (OR EQ.), FUNCTION: ND40 (PRIVACY), LEVER TYPE 07 (ATHENS), FINISH: "SATIN STAINLESS". 1 CLOSERS: 'NORTON' 9500 SERIES (OR EQ.), HEAVY DUTY, NON-HOLD OPEN, FINISH: "ALUMINUM" TYP. 1 "DISABLED" SIGNAGE: 'ADA SIGN DEPOT' (OR EQ.), ACRYLIC, FINISH: "WHITE ON BLUE". 1 SILENCER SET 11DOOR HARDWARE -- 10 " 3' - 0 " DOOR TYPE 'B': CONFERENCE/MANAGER 3'-0" x 8'-0" x 1-3/4" MED. STILE STOREFRONT DOORB PLAS. LAM., BOTH SIDES TYP. (EXISTING STORAGE HARDWARE, GC TO CONFIRM IF COMPLIANT IF NOT REPLACE) D103 B OFFICE 8'-0"1-3/4" AL/GL AL ANOD. 13A/A601 16/A601 13C/A601 02--3'-0" 15STOREFRONT SILL 3" = 1'-0" 17FRAMELESS STOREFRONT HEAD DETAIL 3" = 1'-0" ANOD. ALUM. TOP RAIL CONCEALED CLOSER ANOD. ALUM DOOR STOP AND WEATHERSTRIP A HEAD C SILL 1 2 1/ 2 " M A X . 1/ 4 " M A X . MAX. ANOD. ALUM. THRESHOLD, 4" WIDE, SET IN SEALANT, TYP. B JAMB ANOD. ALUM. MEDIUM STILE TYP. ANOD. ALUM HEAD FRAME EXP. JT. AND CONT. SEALANT TYP. ANOD. ALUM DOOR STOP AND WEATHERSTRIP ANOD. ALUM JAMB 13INTERIOR DOOR 3" = 1'-0" 8" CL R . M I N . ANOD. ALUM. BOTTOM RAIL CONC. SLAB TYP. EXT. HARDSCAPE FIN. SEE FLOOR PLANS TYP. WEATHERSTRIP TYP. SUBMIT SHOP DW'GS FOR ALL STOREFRONT OFFSET PIVOT HINGES (BEYOND) TYP. DOOR SWING 18FRAMELESS STOREFRONT JAMB DETAIL 3" = 1'-0" DOOR GLASS PER MANUFACTURER 9STOREFRONT DOOR DETAIL 3" = 1'-0" CAULKING, ALL AROUND TYP. NARROW WIDTH PROFILE HEADER WITH ADJUSTABLE TOP PIVOT FRAMELESS DOOR TEMPERED GLASS DOOR PER MANUFACTURER GLASS PANEL U-BRACKET TO MATCH ADJACENT, PER MANUFACTURER 5" FINISH TO MATCH (E) ADJACENT FINISH (E) FINISH TO REMAIN AND PROTECT REMOVE (E) DARK BLUE FINISH, PATCH AND REPAIR GYP. BOARD PREP WALL FOR NEW PAINT COLOR, DARK GRAY (E ) P O R T A L F I N I S H T O R E M A I N SE E E L E V A T I O N S (E) 5/8" GYP. BD PATCH AND REPAIR AS NEEDED, PAINT C SILL A HEAD NEW CEILING (ACT). WHERE OCCURS SEE RCP PLAN NEW 3 5/8" X 20 GA. @ 16" O.C. MTL. STUD BOX HEADER TYP. 1" DUAL INSUL. GLASS TYP. ANOD. ALUM. MEDIUM STILE TYP. ANOD. ALUM DOOR STOP AND WEATHERSTRIP ANOD. ALUM JAMB OFFSET PIVOT HINGES, TOP, MIDDLE AND BOTTOM, TYP. 5/8" GYP. BD. BOTH SIDE OVER 3-5/8" METAL STUD @ 16" O.C. CAULKING, ALL AROUND TYP. CONT. SEALANT AND BACKER ROD, BOTH SIDES, ALL AROUND TYP. 5/8" GYP. BD. ON BOTH SIDES FRAMELESS WINDOWN PER MANUFACTURER PAIR 2 x 6 STUDS TYP. FRAMELESS STOREFRONT SYSTEM FOR DESIGN INTENT PROVIDE SHOP DRAWINGS 16INTERIOR DOOR JAMB 3" = 1'-0" MTL. STUD BOX HEADER TYP. 1 2 1/ 2 " M A X . 1/ 4 " M A X . MAX. 362T125-33 TRACK PAIR 2 x 6 600S162-33 STUDS, TYP.12" DIA. x 2 12" CONCRETE ANCHORS @ 16" O.C. (SEALED HEAD) SHIM AS REQ'D. ICC #1385 362T150-54 TRACK FACTORY BONDED LOW PROFILE DOOR TOP RAIL (2) - #10 S.M.S. AT 24" O.C. THRU TRACK. 362S125-54 BLK'G AT 16" O.C. W (2) #10 SMS EA SIDE 1/4-20 ELCO DRILFLEX @ 12" O.C. (ESR-3332) 3 5/8" X 20 GA. @ 16" O.C. DIAGONAL BRACING CONC. SLAB TYP. MANUF. WEEP HOLES IN RECEPTOR. IF MISSING, FIELD DRILL 1/4" DIA. AT 24" O.C. MAX., FULL LGT. TYP. ANOD. ALUM. SILL AND RECEPTOR, SET ON SILL GASKET, AND SHIM AS REQ'D TYP. CONT. SEALANT AND BACKER ROD, BOTH SIDES TYP. SUBMIT SHOP DW'GS FOR ALL STOREFRONT ANOD. ALUM. HEAD WITH CONT. DEFLECTION RAIL TYP. 1" DUAL INSUL. GLASS TYP. ± 1 " 8'-0" T.O. STOREFRONT 1" DUAL INSUL. GLASS TYP. ANOD. ALUM JAMB CONFERENCE ROOM OPEN OFFICES NOTES: 1. 1/ 4 " M A X . 1/4" MAX. 1/2" MAX. 2 1 LEVEL CHANGES THRESHOLD TRANSITION BETWEEN FLOOR FINISHES REFER TO ACCESSIBILITY NOTES SECTION "N" COMPRESSED CARPET 1/4" MAX. BELOW THRESHOLD FIN. FLOOR EVEN THRESHOLD 1/2" MAX. PILE HEIGHT AT 1:2 SLOPE A B C 19TRESHOLD / LEVEL CHANGES N.T.S. A601 DOOR SCHEDULE A PROJECT FOR: SHEET DESCRIPTION: SHEET NUMBER: AS INSTRUMENTS OF SERVICE, ALL DESIGNS, IDEAS, AND INFORMATION SHOWN ON THESE DRAWINGS ARE AND SHALL REMAIN THE PROPERTY OF MMA ARCHITECTURE. NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF MMA ARCHITECTURE VISUAL CONTACT WITH THESE DRAWINGS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. DATE: JOB NUMBER: DRAWN BY: ISSUES / REVISIONS No.DATE CHECKED BY: DESCRIPTION 24136FMA AM HR 2024-09-05 2024-09-13 1ST PLAN CHECK SUBMITTAL 400 S. BALDWIN AVENUE, ARCADIA, CA 91007 THE SHOPS SANTA ANITA 400 S. BALDWIN AVENUE, ARCADIA, CALIFORNIA 91007 THE SHOPS SANTA ANITA MARKETING OFFICE 2024-10-30 PLAN CHECK RE-SUBMITTAL 2024-12-10 PLAN CHECK RE-SUBMITTAL 2025-01-10 PLAN CHECK RE-SUBMITTAL 2025-03-26 VE REVISIONS 2025-05-07 VE REVISIONS 2 2025-06-25 VE REVISIONS 2.1 PC3 PC2 PC3 PC3 PC3 PC3 R1 R1 R1 R1 R2 R2 R2 6.26.25 6.26.25 6.26.25 6.26.25 6.26.25 6.26.25 6.26.25 6.26.25 0' - 9 1 / 4 " 0' - 5 " 5' - 3 " 6.26.25 6.26.25 6.26.25 6.26.25