Loading...
HomeMy WebLinkAbout400 S Baldwin Ave # FC2 - 2025 - Tataypa Peruvian Kitchen2 3 4 6 5 6 5 9 10 11 12 7 8 13 14 15 1.FIREPROOFING (GENERAL CONTRACTOR TO REPAIR AS REQUIRED WITH SPRAYED MONOKOTE OR EQUAL). 2.EPOXY NORTH THE SHOPS AT SANTA ANITA CONTACT: JAMES LAM 400 S. BALDWIN AVENUE, SUITE FC2 ARCADIA, CALIFORNIA 91007 TELEPHONE: 626.617.4556 EMAIL: james@shopsatsantaanita.com TAG DESIGN WORKS ARCHITECT: JOHNNY LU CONTACT: WING HO 411 E. HUNTINGTON DR., SUITE 308 ARCADIA, CA 91006 TELEPHONE: 626.446.5300 EMAIL: who@tagdesignworks.com ARCHITECT: MECHANICAL ENGINEER: 1 2 3 4 6 5 6 5 7 TENANT IMPROVEMENTS TO AN EXISTING SPACE IN THE FOOD COURT AT THE SHOPS AT SANTA ANITA LANDLORD: FIRE RESISTANCE FOR BUILDING ELEMENTS (CBC TABLE 601) ROOF CONSTRUCTION AND SECONDARY MEMBERS......... 1 BUILDING ELEMENT TYPE II- A FLOOR CONSTRUCTION AND SECONDARY MEMBERS........ 1 NON-BEARING WALLS AND PARTITIONS INTERIOR............................................................... 0 PRIMARY STRUCTURAL FRAME......................................... 1 BEARING WALLS EXTERIOR.............................................................. 1 INTERIOR............................................................... 1 ROOMS AND ENCLOSED SPACES CLASS A: = FLAME SPREAD INDEX 0-25; SMOKE DEVELOPED INDEX 0-450 CLASS B: = FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED INDEX 0-450 CLASS C: = FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0-450 CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND EXIT ACCESS RAMPS BL # TI-25-1702 MECHANICAL PLUMBING G000 COVER SHEET G101 G201 GENERAL NOTES G301 CALIFORNIA GREEN CHECK LIST ACCESSIBILITY NOTES ACCESSIBILITY NOTES ACCESSIBILITY DETAILS ACCESSIBILITY DETAILS SITE PLAN DEMOLITION FLOOR PLAN & REFLECTED CEILING PLAN PROPOSED FLOOR PLAN & REFLECTED CEILING PLAN ROOF PLAN INTERIOR ELEVATIONS INTERIOR PARTITION DETAILS TYPICAL CEILING DETAILS PROJECT DIRECTORY INDEX OF DRAWINGS ARCHITECTURALPROJECT SCOPE LEGAL DESCRIPTION PROJECT LOCATION APPLICABLE CODES CONTRACTOR SHALL HAVE A COPY OF EACH OF THESE CODE BOOKS AVAILABLE AT THE JOB SITE AT ALL TIMES. CONSTRUCTION TYPE (CBC SECTION 602.2 TO 602.5) ALLOWABLE AREA (CBC TABLE 504.4) (CBC SECTION 506 & TABLE 506.2) ALLOWABLE HEIGHT (TABLE 504.3) OCCUPANCY GROUP (CBC SECTION 302) SMOKE & FLAME SPREAD RATING FOR INTERIOR FINISHES (CBC SECTION 803 & TABLE 803.13)INTERIOR EXIT STAIRWAYS, INTERIOR EXIT RAMPS AND EXIT PASSAGEWAYS ASSESSOR'S ID NO. : 5775-031-034 POR OF LOT 3 P M 89-76-77 & POR OF LOT 1 P M 261-91-95 400 S. BALDWIN AVENUE, SUITE FC2, ARCADIA, CA. 91007 1 SPECIAL INSPECTIONS DEFERRED SUBMITTALS SEPARATE PERMITS VICINITY MAP SPRINKLERED CALIFORNIA BUILDING CODE2022 CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA ELECTRICAL CODE CALIFORNIA FIRE CODE CALIFORNIA ENERGY CODE- TITLE 24 SPRINKLER FIRE ALARM II-A (FULLY SPRINKLERED) EGRESS & CODE SIGNAGE PLAN PROJECT SUMMARY OCCUPANCY GROUP - - G401 G402 G403 G404 AS101 A001 A101 A102 A401 A510 A515 MECHANICAL LEAD SHEETM-00 THE SHOPS AT SANTA ANITA TATAYPA PERUVIAN KITCHEN (SUITE FC2) 400 S. BALDWIN AVENUE, ARCADIA, CA. 91007 CALGREEN CODE G000 TITLE SHEET B B C C TENANT IMPROVEMENT AREA OF WORK 626 S.F. UP D A T E DEFERRED SUBMITTALS SHALL FIRST BE SUBMITTED TO THE PROJECT ARCHITECT, ENGINEER AND/OR OWNER. FOR REVIEW AND COORDINATION, FOLLOWING THE COMPLETION OF THE PROJECT ARCHITECT OR ENGINEER'S REVIEW AND COORDINATION A SUBMITTAL TO THE CITY SHALL BE MADE WHICH SHALL INCLUDE A LETTER STATING THIS REVIEW AND COORDINATION HAS BEEN PERFORMED AND COMPLETED AND PLANS & CALCULATIONS FOR THE DEFERRED ITEMS ARE FOUND TO BE ACCEPTABLE WITH NO EXCEPTIONS. CBC 107.3.4.1. DEFERRED ITEMS ARE: 1. AUTOMATIC FIRE SPRINKLER 2. FIRE ALARM ELECTRICAL STORY LIMITATIONS (TABLE 504.4) 1.FIRE SPRINKLER SYSTEM 2.FIRE ALARM SYSTEM 3.TENANT SIGNAGE 4.KITCHEN HOOD FIRE EXTINGUISHING SYSTEM AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK 2022 2022 2022 2022 2022 2022 NO CHANGE NO CHANGE NO CHANGE B SITE PLUMBING ENGINEER: ELECTRICAL ENGINEER: MWQ ENGINEERING CONTACT: MOTAZ W QUDAH 5 UPPER NEWPORT PLAZA DRIVE, SUITE 202 NEWPORT BEACH, CALIFORNIA 92660 TELEPHONE: 562.413.9495 EMAIL: MOTAZ@MWQENG.COM MECHANICAL FLOOR PLANM-01 GREASE HOOD DETAILSM-02 GREASE HOOD DETAILSM-03 GREASE HOOD DETAILSM-04 GREASE HOOD DETAILSM-05 GREASE HOOD DETAILSM-06 GREASE HOOD DETAILSM-07 GREASE HOOD DETAILSM-08 GREASE HOOD DETAILSM-09 GREASE HOOD DETAILSM-10 ENERGY COMPLIANCE FORMSM-11 PLUMBING LEAD SHEETP-00 8 9 10 11 12 PLUMBING FLOOR PLANP-01 1 2 ELECTRICAL SYMBOLS, NOTES & SHEET INDEXE0.01 2 3 POWER LAYOUT & SINGLE LINE DIAGRAME1.0 ROOF PLAN POWER LAYOUTE2.0 JORGE WONG TELEPHONE: 626.241.7868 EMAIL: jorgewo@yahoo.com TENANT: MWQ ENGINEERING CONTACT: MOTAZ W QUDAH 5 UPPER NEWPORT PLAZA DRIVE, SUITE 202 NEWPORT BEACH, CALIFORNIA 92660 TELEPHONE: 562.413.9495 EMAIL: MOTAZ@MWQENG.COM MWQ ENGINEERING CONTACT: AMIR JAZAYERI 5 UPPER NEWPORT PLAZA DRIVE, SUITE 202 NEWPORT BEACH, CALIFORNIA 92660 TELEPHONE: 562.413.9495 EMAIL: AMIR@MWQENG.COM ENERGY COMPLIANCE FORMSM-1213 WALL, FLOOR & CEILING SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.11 16 KITCHEN HOOD ATTACHMENT DETAILSA516 SERVICE COUNTER KITCHEN KITCHEN SUPPORT FE FE E100 6 O C C TR A V E L D I S T A N C E 5 0 ' - 0 " < 2 5 0 ' - 0 " 10.0610.36 10.353' - 8 " M I N I M U M CL E A R SCALE:26 EGRESS & CODE SIGNAGE PLAN 1/2" = 1'-0" EXIT WIDTH REQUIREMENTS DOOR NO.OCCUPANT LOAD EXIT WIDTH REQUIRED OCC. (0.2) EXIT WIDTH PROVIDED E100 6 1.2"38" OCCUPANT LOAD CALCULATION PER TABLE 1004.5 ROOM #ROOM NAME AREA S.F.OCC.LOAD OCC. FACTOR OCC. LOAD 100 SERVICE COUNTER 169 B 150 2 101 KITCHEN 289 B 150 2 102 KITCHEN SUPPORT 165 B 150 2 TOTALS 623 6 PATH OF TRAVEL (44" MINIMUM) OCCUPANT LOAD AT EXIT SUITE FC2 HAS AN OCCUPANT LOAD OF 6 6 < 50, THEREFORE SUITE FC2 REQUIRES ONLY A SINGLE EXIT ILLUMINATED EXIT SIGN (SEE ELECTRICAL PLANS) LEGEND TACTILE 'EXIT' SIGNAGE WALL HUNG FIRE EXTINGUISHER - PROVIDE 4"X12" 3-WAY SIGN A5000-MN BY SAFETYSIGN OR EQUAL (ABOVE FIRE EXTINGUISHER) 12 OCC EXIT NUMBER OF EXITS: 1 REQUIRED NUMBER OF EXITS: 1 PROVIDED EXITING REQUIREMENTS KEYNOTES DESCRIPTION DETAIL G101 FIRE, LIFESAFETY AND CODE SIGNAGE PLAN GENERAL NOTES INTERIOR CODE SIGNAGE GENERAL NOTES: 1.SIGNAGE SHALL BE ACRYLIC WITH SMOOTH EDGES CONFORMING TO ANSI Z97.1: COLOR AS SELECTED BY OWNER / ARCHITECT. 2.SIGNAGE SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH CODE REQUIREMENTS. 3.ALL CODE SIGNAGE SHALL BE ACQUIRED FROM ADA SIGN DEPOT (WWW.ADASIGNDEPOT.COM). 28B / G40410.06 10.35 WALL HUNG 6 LITTER K-TYPE FIRE EXTINGUISHER - PROVIDE 4"X12" 3-WAY SIGN A5000-MN BY SAFETYSIGN OR EQUAL (ABOVE FIRE EXTINGUISHER)10.36 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK REFER TO METAL STUD SIZE OR CMU NOM WIDTH AS INDICATED BY THE "METAL STUD/CMU WIDTH" CHARACTER ON THE TAG, AS SHOWN ON PARTITION TYPE DETAILS, FOR EXAMPLE "3"=3-5/8" METAL STUDS. REFER TO SHEET A510 FOR TYPICAL FRAMING DETAILS. GENERAL NOTES-SEISMIC ZONES IBC D-F, CBC3-4: ALL METAL STUD PARTITION TYPES SHALL COMPLY WITH PARTITION TYPE GENERAL NOTES, AND ALL METAL STUDS SHALL BE MIN 20 GA, UNO. ALL CMU PARTITION TYPES SHALL COMPLY WITH PARTITION TYPE GENERAL NOTES, AND REINFORCING AS INDICATED ON THE STRUCTURAL DRAWINGS, UNO. PARTITION TYPE GENERAL NOTES WALL TYPE NOTES: 1.TYPE "X" GYP WALL BOARD SPECIFIED THROUGHOUT UNLESS OTHERWISE SPECIFIED. PROVIDE MOISTER RESISTANT GYP BOARD AT ALL WET WALLS. PROVIDE TILE BACKER BOARD ON ALL WALLS WITH TILE. FIRE RESISTANT ASSEMBLIES TILE BACKER BOARD SHALL BE PROVIDED OVER THE FIRE RESISTANT SYSTEM. 2.INSTALL CONTROL JOINTS MAXIMUM 30'-0" O.C. INTERVAL WHERE A CONTROL JOINT OCCURS IN AN ACOUSTICAL OR FIRE RATED SYSTEM, BLOCKING SHALL BE PROVIDED BEHIND THE CONTROL JOINT BY USING A BACKING MATERIAL SUCH AS 5/8" TYPE "X" GYP BOARD, MINERAL FILLER OR OTHER TESTED EQUIVALENT. 3.CONFORM TO DETAILED REQUIREMENTS OF DESIGNATED TESTING AUTHORITY NUMBERS AT ALL WALLS. WALLS DESIGNATED AS "BASED ON" VARY AS NOTED IN PARENTHESIS. SEE STRUCTURAL SHEAR WALLS SCHEDULE FOR SHEAR WALL ATTACHMENT AND EDGE BLOCKING REQUIREMENTS WHERE APPLICABLE. STRUCTURAL SHEAR WALL SCHEDULE OVERRIDES LISTED ASSEMBLY ATTACHMENT AND BLOCKING REQUIREMENTS ONLY WHEN MORE RESTRICTIVE. 4.WALL TYPES STATED AS "BASED ON" A LISTED ASSEMBLY MIGHT VARY IN STUD SIZE. NO EXACT LISTED ASSEMBLY EXISTS. PER GA-600-2012 P.9 ITEM 16, "GREATER STUD SIZES (DEPTH) SHALL BE PERMITTED TO BE USED IN METAL - OR WOOD - STUD SYSTEMS." THESE WALLS CAN ALSO BE SHOWN TO MEET THE REQUIRED FIRE RESISTIVE RATING BY THE CALCULATION METHOD PER SECTION 703.3.3 AND SECTION 721 IF REQUIRED. 5.WALL TYPES STATED AS "BASED ON" A LISTED ASSEMBLY MIGHT VARY DUE TO ADDITION OF EXTRA LAYER(S) OF ELEMENTS. NO EXACT LISTED ASSEMBLY EXISTS. PER GA-600-2012 P. ITEM 22, "ADDITIONAL LAYERS OF TYPE "x" OR REGULAR GYP BOARD SHALL BE PERMITTED TO BE ADDED TO ANY SYSTEM." FASTENERS SPECIFIED FOR THE ATTACHMENT OF GYP BOARD APPLIED OVER THE ADDITIONAL LAYER(S) OF ELEMENTS SHALL BE INCREASED BY NOT LESS THAN THE THICKNESS OF THE ADDITIONAL LAYER(S). 6.METALLIC OUTLET BOXES SHALL BE PERMITTED TO BE INSTALLED IN WOOD AND STEEL STUD WALLS OR PARTITIONS HAVING GYPSUM BOARD FACINGS AND CLASSIFIED AS TWO HOURS OR LESS. THE SURFACE AREA OF INDIVIDUAL BOXES SHALL NOT EXCEED 16 SQUARE INCHES. THE AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE FEET. BOXES LOCATED ON OPPOSITE SIDES OF WALLS OR PARTITIONS SHALL BE IN SEPARATE STUD CAVITIES AND SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. APPROVED NONMETALLIC BOXES SHALL BE PERMITTED AS ALLOWED BY LOCAL CODE. A.GENERAL REQUIREMENTS 1.AIA DOCUMENT A201 - 2007 GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION ARE HEREBY INCLUDED AS PART OF THE CONTRACT DOCUMENTS AND OWNER/CONTRACTOR AGREEMENT. 2.SOLELY AS A CONVENIENCE TO THE OWNER, THE ARCHITECT MAY INCLUDE DOCUMENTS PREPARED BY CERTAIN CONSULTANTS (OR INCORPORATE THE RECOMMENDATIONS OF SAID CONSULTANTS IN DOCUMENTS PREPARED BY THE ARCHITECT) WITHIN THE SET OF DOCUMENTS ISSUED BY THE ARCHITECT BEING EXPRESSLY UNDERSTOOD THAT, BY SAID ISSUANCE, THE ARCHITECT ASSUMES NO LIABILITY FOR THE SERVICES OF SAID CONSULTANTS NOT UNDER CONTRACT TO THE ARCHITECT. 3.THE ENTIRE WORK SHALL BE WARRANTED AGAINST DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. THE WARRANTY SHALL SPECIFICALLY PROVIDE THAT ALL DEFECTS IN MATERIAL AND WORKMANSHIP APPEARING DURING THE WARRANTY PERIOD, AS DETERMINED BY THE ARCHITECT, WILL BE REMEDIED TO THE SATISFACTION OF THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL SECURE AND FURNISH TO THE OWNER AS A CONDITION PRECEDENT TO FINAL ACCEPTANCE AND PRIOR TO APPLICATION FOR PAYMENT, ALL WRITTEN GUARANTEES AND WARRANTIES, A LIST OF NAMES, ADDRESSES, AND TELEPHONE NUMBERS OF ANY AND ALL SUB-CONTRACTORS USED FOR THE CONSTRUCTION AND SERVICES. 4.THESE PLANS AND RELATED DOCUMENTS MUST BE AVAILABLE AT THE JOB SITE AT ALL TIMES & BE AVAILABLE DURING ANY INSPECTION ACTIVITY PER C.B.C. 5.WORK WITHIN THE AREA BOUNDARIES INDICATED IN THE PROJECT DOCUMENTS SHALL COMPLY WITH ALL APPLICABLE BUILDING CODE REGULATION AND ORDINANCE REQUIREMENTS. OCCUPANTS ADJACENT TO THE PROJECT ARE BOUNDARIES SHALL CONTINUE UNINTERRUPTED OCCUPANCY DURING CONSTRUCTION OF THE PROJECT. 6.CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY TO CONTINUOUSLY AND NOT BE LIMITED TO NORMAL HOURS: AND THE CONTRACTOR SHALL DEFEND: INDEMNIFY AND HOLD THE OWNER & ARCHITECT HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. 7.CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE RULES AND REGULATIONS OF THE LANDLORD IN THE PERFORMANCE OF THE WORK. A COPY OF THE RULES AND REGULATIONS ARE AVAILABLE FROM THE LANDLORD UPON REQUEST. 8.CONTRACTORS INSURANCE REQUIREMENTS PER LANDLORD RULES AND REGULATIONS AND TENANT REQUIREMENTS. EACH POLICY OF INSURANCE SHALL NAME THE LANDLORD AND TENANT, SUCCESSORS, AND ASSIGNS WITHOUT ADDITIONAL CHARGE. THE CONTRACTOR SHALL CERTIFY TO THE OWNER THAT HE HAS OBTAINED SIMILAR CERTIFICATES OR MEMORANDUM EVIDENCE FORM EACH OF THE SUBCONTRACTORS BEFORE THEIR WORK COMMENCES. EACH SUBCONTRACTOR MUST BE COVERED BY INSURANCE OF THE SAME CHARACTER, NAMING THE CONTRACTOR AN THE OWNER AS ADDITIONAL INSUREDS. 9.CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID TO FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS. 10.THE CONTRACTOR SHALL EXAMINE THE DRAWINGS AND SPECIFICATIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. 11.THE CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 12.THE CONTRACTOR SHALL INSPECT EXISTING CONDITIONS, INCLUDING ELEMENTS SUBJECT TO MOVEMENT OR DAMAGE DURING DEMOLITION, CUTTING AND PATCHING. AFTER UNCOVERING THE WORK, INSPECT CONDITIONS AFFECTING INSTALLATION OF NEW WORK. IF UNCOVERED CONDITIONS ARE NOT AS ANTICIPATED, IMMEDIATELY NOTIFY THE ARCHITECT AND SECURE NEEDED DIRECTIONS. DO NOT PROCEED IN AREAS OF DISCREPANCY UNTIL ALL SUCH DISCREPANCIES HAVE BEEN FULLY RESOLVED. 13.THE CONTRACTOR SHALL PROVIDE ALL REQUIRED PROTECTION PRIOR TO CUTTING, INCLUDING BUT NOT NECESSARILY LIMITED TO SHORING, BRACING AND SUPPORT TO MAINTAIN STRUCTURAL INTEGRITY OF THE EXISTING WORK. THE CONTRACTOR SHALL CAREFULLY PROTECT ALL EXISTING FINISHES TO REMAIN SUCH AS WALL COVERING, FLOORING, CEILING AND DOORS. HE SHALL PERFORM ALL CUTTING AND DEMOLITION BY METHODS WHICH WILL PREVENT DAMAGE TO OTHER PORTIONS OF THE WORK AND WILL PROVIDE PROPER SURFACES TO RECEIVE INSTALLATION OF NEW WORK. PERFORM FITTING AND ADJUSTMENT OF PRODUCTS TO PROVIDE FINISHES INSTALLATION COMPLYING WITH THE SPECIFIED TOLERANCES AND FINISHES. 14.THE ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY ACTION TAKEN BY ANYONE ON THE PROJECT IF THAT PERSON HAS KNOWLEDGE OF ANY DISCREPANCY, OMISSION, OR AMBIGUITY IN THE DRAWINGS OR SPECIFICATIONS UNTIL THE ARCHITECT HAS BEEN NOTIFIED, CORRECTED THE DISCREPANCY, MADE THE INCLUSION OR MORE CLEARLY EXPLAINED THE INTENT OF THE DRAWINGS OR SPECIFICATIONS. 15.GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE COORDINATION OF THE VARIOUS TRADES PERFORMING THE WORK. CONTRACTOR SHALL SUBMIT FOR REVIEW COMPLETE, COMPOSITE COORDINATION SHOP DRAWINGS ILLUSTRATING THE EXTENT AND POSITION OF EACH COMPONENT OF THE WORK AS TO AVOID CONFLICT AND TO MAINTAIN REQUIRED SERVICE ACCESS AND CODE REQUIRED CLEARANCES. NO WORK SHALL BE PERFORMED UNTIL REFERENCED COORDINATION SHOP DRAWINGS HAVE BEEN REVIEWED WITH NO EXCEPTION TAKEN. 16.DO NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. 17.THE CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF DRAWINGS AT THE JOB SITE FOR USE IN MAKING "RECORD DRAWINGS." ANY REVISIONS SHALL BE NOTED THEREON AND SUBMITTED TO THE ARCHITECT AT THE COMPLETION OF THE JOB PER THE PROJECT MANUAL. PROVIDE A COPY FOR THE OWNER PER CONSTRUCTION DOCUMENTS. 18.THE ARCHITECT IS AUTHORIZED TO ORDER MINOR CHANGES DURING THE COURSE OF THE WORK WHICH WILL NOT INVOLVE EXTRA COST OR TIME AND WHICH ARE CONSISTENT WITH THE CONTRACT DOCUMENTS. 19.THE OWNER AND/OR ARCHITECT RESERVE THE RIGHT TO HAVE TESTS MADE WHEN DEEMED NECESSARY. SHOULD THE ARCHITECT ORDER SPECIAL TESTING OR INSPECTION OF A QUESTIONABLE PART OF THE WORK WHICH REVEALS DEFECTS NOT IN CONFORMITY WITH THE CONTRACT DOCUMENT, THE CONTRACTOR SHALL PAY THE COST OF SUCH SPECIAL TESTING OR INSPECTIONS INCLUDING THE ARCHITECTS EXTRA SERVICES MADE NECESSARY THEREBY. OTHERWISE THE OWNER SHALL BEAR THE COST. 19.1.TESTS SHALL BE MADE IN ACCORDANCE WITH RECOGNIZED STANDARDS BY COMPETENT, INDEPENDENT TESTING LABORATORY. ANY MATERIAL FOUND DEFECTIVE OR NOT IN CONFORMITY WITH THE SPECIFICATION STANDARDS SHALL BE PROMPTLY REPLACED OR REPAIRED AT THE EXPENSE OF THE CONTRACTOR. SAMPLES REQUIRED FOR TESTING WILL BE FURNISHED BY THE CONTRACTOR AND SELECTED AS DIRECTED BY THE ARCHITECT. 20.THE CONTRACTOR SHALL RETAIN ALL STORED ITEMS IN AN ORDERLY ARRANGEMENT ALLOWING MAXIMUM ACCESS, NOT IMPEDING WALKWAYS AND PROVIDING THE REQUIRED PROTECTION OF MATERIALS. 21.THE CONTRACTOR SHALL MAINTAIN THE PROJECT AREA IN A NEAT AND ORDERLY CONDITION AT ALL TIMES, NOT ALLOWING THE ACCUMULATION OF SCRAP, DEBRIS, WASTE MATERIAL AND OTHER ITEMS NOT REQUIRED FOR CONSTRUCTION OF THIS WORK. 22.THE CONTRACTOR SHALL CONDUCT THE FINAL CLEANING OF ALL AREAS AFFECTED BY THIS WORK. VISUALLY INSPECT ALL INTERIOR SURFACES AND REMOVE ALL TRACES OF SOIL, WASTE MATERIAL, SMUDGES AND OTHER FOREIGN MATTER. REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT SURFACES. REMOVE ALL PAINT DROPPINGS, SPOTS, STAINS AND DIRT FROM FINISHED SURFACES. USE ONLY THE SPECIFIED CLEANING MATERIALS AND EQUIPMENT. CLEAN AND POLISH ALL GLASS EITHER INSTALLED OR AFFECTED BY THIS WORK. 23.THE CONTRACTOR SHALL PROVIDE AND COORDINATE THE EXACT DIMENSIONS, SIZES AND POSITIONS OF ALL OPENINGS IN FLOOR AND WALL CONSTRUCTION NECESSARY FOR THE INSTALLATION OF THE WORK. CONFIRM LOCATION WITH THE PROJECT MANAGEMENT TEAM PRIOR TO BEGINNING THE WORK. 24.CONTRACTOR SHALL XRAY/RADAR TO LOCATE ALL REINFORCEMENT AND UTILITIES IN STRUCTURAL CONCRETE SLABS, BEAMS, WALLS ETC. PRIOR TO DRILLING, CUTTING OR INSTALLING FASTENERS. 25.PENETRATIONS INTO AND THROUGH PARTITIONS CONTAINING SOUND INSULATION BATTS SHALL BE SEALED WITH PERMANENT RESILIENT SEALANT SPECIFIED FOR THAT PURPOSE. ELECTRICAL DEVICES, RECESSED CABINETS, ETC. SHALL BE SEALED, LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN THE INTEGRITY OF THE ACOUSTICAL ASSEMBLY. ALL PENETRATIONS THROUGH MATERIALS PROVIDING FIRE PROTECTION SHALL BE SEALED TO MAINTAIN REQUIRED FIRE RATING. 26.ALL PIPING AND DUCT WORK, VALVES, DAMPERS, CONTROLS AND TERMINATIONS SHALL BE INSTALLED AT LOCATIONS WHICH PROVIDE SAFE, DIRECT AND EASY ACCESS. PROVIDE ACCESS DOORS AT WALLS AND CEILINGS FOR ACCESS WHERE REQUIRED, WHETHER SHOWN ON THE DRAWINGS OR NOT, WITH NO ADDITIONAL COST TO THE OWNER. 27.ALL ATTACHMENTS TO AND PENETRATIONS THROUGH CONCRETE NOTED ON THE DRAWINGS TO BE WATERPROOFED SHALL BE MADE PRIOR TO APPLICATION OF THE WATERPROOFED MATERIAL. 28.CUTTING, BORING, SAW-CUTTING OR DRILLING THROUGH THE NEW OR EXISTING STRUCTURAL ELEMENTS TO BE DONE ONLY WHEN SO DETAILED IN THE DRAWINGS OR REVIEWED AND ACCEPTED BY THE STRUCTURAL ENGINEER. 29.PENETRATION THROUGH FIRE RATED FLOORS AND WALLS SHALL BE PROVIDED IN ACCORDANCE WITH THE CBC SECTIONS 709.6 AND 714 SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE PROVIDED FOR REVIEW BY INSPECTION AUTHORITIES. SUBSTITUTIONS OF OR REVISIONS OR ADDITIONS TO APPROVED SYSTEMS SHALL BE SUBMITTED TO THE INSPECTOR OF RECORD AND THE FIRE DEPARTMENT FOR FIELD REVIEW AND APPROVAL. 30.THE CONTRACTOR SHALL NOT INTERRUPT EXISTING UTILITIES SERVING EXISTING FACILITIES, EXCEPT WHEN AUTHORIZED IN WRITING BY THE OWNER AND ALL AUTHORITIES HAVING JURISDICTION. PROVIDE TEMPORARY SERVICES DURING CONSTRUCTION ACTIVITIES ACCEPTABLE TO LANDLORD AND GOVERNING AUTHORITIES. 31.THE WORK SHALL INCLUDE ALL REMOVALS NOT SPECIFICALLY INDICATED ON DRAWINGS BUT NECESSARY FOR THE COMPLETION OF WORK. 32.THE CONTRACTOR SHALL KEEP ALL EXITS READILY ACCESSIBLE AND UNOBSTRUCTED AT ALL TIMES. B.DEFINITIONS 1.WHEN A DETAIL IS IDENTIFIED AS TYPICAL. THE CONTRACTOR SHALL APPLY THIS DETAIL TO EVERY LIKE CONDITION WHETHER OR NOT THE REFERENCE IS REPEATED IN EVERY INSTANCE. WHEN A NOTE IS IDENTIFIED AS TYPICAL (TYP.), THE CONTRACTOR SHALL APPLY THIS NOTE TO EVERY LIKE CONDITION (REPRESENTED GRAPHICALLY OR NOT) WHETHER OR NOT THE REFERENCE IS REPEATED IN EVERY INSTANCE. 2."SIMILAR" INDICATES COMPLETE SYSTEM AND COMPONENTS SHALL BE PROVIDED COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3.AS REQUIRED INDICATES COMPONENTS REQUIRED TO COMPLETE THE NOTES, SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS, SHALL BE PROVIDED. 4.ALIGN INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE & PLUMB RELATION TO ADJACENT MATERIALS. C.PERMITS 1.OWNER WILL REIMBURSE CONTRACTOR FOR THE COST OF BUILDING PERMIT. COST OF ALL OTHER PERMITS BY CONTRACTOR. 2.COST FOR THE INSTALLATION OF THE TEMPORARY BARRICADE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL MAINTAIN BARRICADE DURING CONSTRUCTION AND REMOVE WHEN CONSTRUCTION IS COMPLETE. 3.SEPARATE PERMITS SHALL BE OBTAINED FOR PEDESTRIAN PROTECTION, DEMOLITION, PLUMBING, MECHANICAL ELECTRICAL, FIRE SPRINKLER, AND FIRE ALARM AS REQUIRED BY THE LOCAL GOVERNING AGENCIES OR FIRE SPRINKLER AND FIRE ALARM AGENCIES. THE COST FOR THE SEPARATE PERMITS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4.COST FOR THIRD PARTY INSPECTIONS AND TESTING SHALL BE THE RESPONSIBILITY OF THE OWNER. ALL OTHERS ARE THE RESPONSIBILITY OF THE CONTRACTOR. MATERIAL LEGEND ELECTRICAL LEGEND DURESS ALARM SWITCH WALL MOUNTEDDA HS VCR HORN / STROBE DOOR BELL VIDEO RECORDER SECURITY ALARM KEYPAD SMOKE DETECTOR JUNCTION BOX IN WALL JUNCTION BOX ABOVE CEILING J J SAK v AUDIBLE ALARM VISUAL ALARM SD EXHAUST FAN CARD READER THERMOSTATT P PANIC BUTTON M MOTION SENSOR IN WALL MONITORM MOTION SENSOR ON CEILINGM CAMERA WITH DATA OUTLET WIRELESS ACCESS POINT WITH DATA OUTLETWAP DEDICATED DUPLEX ELECTRICAL OUTLET TELE-POWER POLE W/ 4 ELECTRICAL OUTLETS VOICE & DATA OUTLET w/ TERMINATION FACEPLATE DATA OUTLET w/ TERMINATION FACEPLATE VOICE OUTLET w/ TERMINATION FACEPLATE 220V. ELECTRICAL OUTLET QUADRUPLEX ELECTRICAL OUTLET THREE-WAY LIGHT SWITCH DUPLEX ELECTRICAL OUTLET LIGHT SWITCH FLOOR WALL DEDICATED QUADRUPLEX ELECTRICAL OUTLET d.d. d.d. RECESSED ELECTRICAL PANEL SECTION NUMBER SHEET NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER ELEVATION NUMBER ROOM TAG FIRE EXTINGUISHER IN RECESSED CABINET CONCRETE MASONRY BLOCK GYPSUM BOARD STUCCO / PLASTER RIGID INSULATION FINISHED WOOD - AS NOTED CONTINUOUS WOOD BATT INSULATION EARTH PLYWOOD CONCRETE METAL WOOD BLOCKING E.F.I.S. WORK POINT, DATUM POINT DOOR NUMBER ROOM NUMBER ELEVATION NUMBER SHEET NUMBER GRID REFERENCE SEE ELECTRIC DRAWINGS ILLUMINATED EXIT SIGN REVISION NUMBER ELEVATION SHOWN WALL TYPES-REFER TO SHEET A511 CONSTRUCTION KEYNOTES DEMOLITION KEYNOTES INTERIOR ELEVATION MATERIALS FIXTURE SCHEDULE REFER TO ELEVATION SHEET COLOR & MATERIAL REFERENCE EQUIPMENT SCHEDULE A - - - - -- - 7.05 - -CEILING TYPE AND CEILING HEIGHT WINDOW NUMBER - ABBREVIATIONS AND SYMBOLS ℄ DIA. C.L., AMERICAN DISABILITIES ACT ACOUSTICAL CEILING TILE CENTER LINE AND PERPENDICULAR ANCHOR BOLT CHANNEL AIR CONDITIONING ASPHALTIC CONCRETE POUND OR NUMBER DIAMETER OR ROUND AREA DRAIN ADJUSTABLE ADJACENT ARCHITECTURAL APPROXIMATE ALUMINUM ABOVE FINISH FLOOR AUTOMATIC SPRINKLER ACOUSTICAL AT & @ # A/C AC AB ADA ARCH. APPROX. AD ACT A.F.F. A.S.R. ALUM. ADJ ACOUS. CONTROL JOINTC.J. COLUMN CLEAR CEILING CERAMIC TILE COUNTERSUNK CONTINUOUS CONNECTION CENTER, COUNTER CONTRUCTION DEPARTMENT DOUGLAS FIR DOUBLE DRINKING FOUNTAIN CONCRETE C.T. CTSK. CONT. CONN. D.F. DEPT. DBL. CTR. CONST. CONC. COL. CLR. CLG. BUILDING BOARD CARPET BETTER BLOCKING BOTTOM BEAM CAST IRON CATCH BASIN CABINET BLOCK BD. BM. C.I. BTR. BLKG. C.B. CAB. BOT. BLK. BLDG. CPT. DETAIL DOOR OPENING DOWNSPOUT DETAIL DOOR DOWN DIMENSION DRAWING DIAMETER DN. DR. DIA. DO DWG. DTL. D.S. DIM. DET. EAST DRAWER EACH E. EA. DWR. ELECTRIC WATER COOLER ELEVATION EXPANSION JOINT EQUAL EQUIPMENT EXPANSION EXISTING EXHAUST ENCLOSURE EPOXY TOPPING EXTERIOR EXPOSED ELECTRICAL E.J. EQ. E.T. EQUIP. EXIST., (E) E.W.C. EXT. EXP. EXH. ENCL. ELEC. EL., ELEV. FURRING FOOTING FACE OF MASONRY FOOT OR FEET FACE OF STUD FT. FURR. FTG. F.O.M. F.S. F.O.S. FULL SIZE FLOOR SINK FINISH SURFACE FACE OF FACE OF SHEATHING FACE OF FINISHF.O.F. F.O. F.O.SH. FIRE ALARM FLAT BAR FLOOR DRAIN FINISH GRADE FIRE HYDRANT FOUNDATION FACTORY FINISH FINISH FLOOR FINISH FLUORESCENT FLOW LINE FLOOR FIRE EXTINGUISHER F.A. F.E. F.F. FIN. F.L. FLUOR. F.G. F.H. FDN. F.B. FL., FLR. F.D. INSIDE DIMENSIONI.D. INSULATION INFORMATION INSIDE DIAMETER JOIST JANITOR INTERIOR INSUL. INFO. JST. JAN. INT. HOSE BIBB HOLLOW CORE HARDWOOD HARDWARE HEIGHT HORIZONTAL HOLLOW METAL HOUR HIGH POINT HORSE POWER HEADER H.C. H.B. HDWD. HDW. HT HORIZ. HOR. H.M. HR. H.P. HDR. GENERAL CONTRACTOR GAUGE GRAB BAR GALVANIZED GLASS GYP. WALL BOARD GALVANIZED IRON GROUND GYPSUM GALVANIZED STEEL GRADE G.B. GA. GALV. G.C. GL. G.I. GRD. G.S. GYP. GR. MEDIUM DENSITY OVERLAY LIQUID MARKER BOARD LABORATORY CONSTRUCTION JOINT LIGHT LAMINATE MECHANICAL MAXIMUM LAVATORY METAL MANHOLE METAL LATH MINIMUM MISCELLANEOUS MASONRY OPENING MANUFACTURER NORTH MULLION MOUNTED NOMINAL NUMBER NOT IN CONTRACT NOT TO SCALE K.J. LAB. LAM. L.M.B. LT. M.D.O. MECH. MAX. L., LAV M.H. M.L. MET., MTL. MISC. MIN. MFR. M.O. N. MUL. MTD. NOM. NO. N.I.C. N.T.S. PAPER TOWEL DISPENSER ON CENTER OFFICE OVERHEAD OVERFLOW DRAIN OUTSIDE DIMENSION OUTSIDE DIAMETER OPPOSITE OPENING POUR JOINT OVERFLOW SCUPPER PROPERTY LINE PLANTING AREA PLUMBING PLASTER POINT PAIR PLYWOOD PLASTIC LAMINATE PAVEMENT PRESSED METAL PLATE O.D. O.C. O.H. OFF. OPP. O.S. OPNG. P.J. P.L. P.A. PLAM. PLBG. PLAS. PT. PR. PLYWD. P.MET. PVMT. PTD. PL. QUARRY TILEQ.T. RETURN AIR RADIUS ROOF DRAIN ROOM REINFORCED REQUIRED REFERENCE RISER, RADUIS REFRIGERATOR REFRIGERATION RESILIENT RE-SAWN REDWOOD ROUGH SAWN R. R.A. RAD. R.D. REFRIG. RM. REQ'D. REINF. REF. RESIL. R.S. RWD. REVERSEREV. SUSPENDED STRUCTURAL SYMMETRICAL SWITCHBOARD STAINLESS STEEL SERVICE SINK SUSP. S.S. STRUCT. SYM. SWBD. SINK SOUTH SOLID CORE SHEATHING SECTION SUPPLY AIR SHEETING SLIDING SIMILAR SQUARE STATION SCORE LINE STEEL STANDARD STORAGE SHEET SPECIFICATION STORM DRAIN SCUPPER DRAIN SO. S. S.D. S.C. SH. SEC. S.A. SHTG. SL. SIM. STA. SQ. SPEC. STD. STOR. STL. SHT. WEATHERPROOFW.P. WORK POINT WATERPROOF TOP OF CATCH BASIN TOP OF SHEATHING UNLESS OTHERWISE TOILET PAPER DISPENSER VINYL COMPOSITION TILE T. T.B. T.A. T.O.C. T.C. TER. THK. TEL. T.O.SH. T.O.M. T.O.W. T.V. T.P.D. T.J. U.O.N. U.N.O. TYP. T.O.P./T.P. V.I.F. V.C.T. VERT. W. W.C. W/ W.H. WD. T.O.F. TREAD TACK BOARD TREE AREA TRANSFORMER THICK TERRAZZO TOP OF CURB TELEPHONE TOP OF CONCRETE TOWEL BAR TOP OF WALL TELEVISION TOP OF PARAPET TOP OF MASONRY TOOL JOINT OTHERWISE UNLESS NOTED NOTED TYPICAL VERTICAL WEST WITH VERIFY IN FIELD WATER CLOSET WOOD WIDE FLANGE WATER HEATER TOP OF FRAMING T.O.D. TOP OF STEEL DECKING WF. F E D B A G H I J K L M N O P Q R S T U V W ∠ANGLE KICK PLATE MARKER BOARD MOP RACK MODULAR SYSTEM FURNITURE NEW KP MB MR MSF (N) REMOVE VISION PANEL (R) VP TELE/DATA BACKBOARD TBB S.V.SHEET VINYL TBD TO BE DETERMINED SFM STATE FIRE MARSHAL PRISON INDUSTRYPIA AUTHORITY OCCUPANT LOADO.L. C TEMPERED GLASS PANIC HARDWAREPH WT.WEIGHT DUPLEX RECEPTACLE, 20A, 125V UNLESS NOTED OTHERWISE QUAD RECEPTACLE, 20A, 125V UNLESS NOTED OTHERWISE J JUNCTION BOX F S TYPICAL PLAN SYMBOLS (NEW) CEILING MOUNTED, PENDANT LIGHT SPRINKLER HEAD CEILING FAN SMOKE DETECTOR EXIT SIGN EMERGENCY LIGHT 2x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN SPRINKLER RISER GAS METER F S TYPICAL PLAN SYMBOLS (EXISTING) SUPPLY AIR GRILLE RETURN AIR GRILLE SPRINKLER HEAD CEILING FAN SMOKE DETECTOR EXIT SIGN EMERGENCY LIGHT SPRINKLER RISER GAS METER F S TYPICAL PLAN SYMBOLS (DEMOLITION) SPRINKLER HEAD CEILING FAN SMOKE DETECTOR EXIT SIGN EMERGENCY LIGHT SPRINKLER RISER GAS METER 1x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN STRIP LIGHT FIXTURE-SEE ELECTRICAL PLAN CEILING MOUNTED LIGHT 2x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN 1x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN STRIP LIGHT FIXTURE-SEE ELECTRICAL PLAN CEILING MOUNTED LIGHT 2x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN 1x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN STRIP LIGHT FIXTURE-SEE ELECTRICAL PLAN CARBON MONOXIDE DETECTOR RECESSED LIGHT FIXTURE C SUPPLY AIR GRILLE SUPPLY AIR GRILLE RETURN AIR GRILLE SUPPLY AIR GRILLE SUPPLY AIR GRILLE RETURN AIR GRILLE SUPPLY AIR GRILLE WALL MOUNTED LIGHT FIXTURE CARBON MONOXIDE DETECTORC CARBON MONOXIDE DETECTORC UNIT PANELBOARD, FLUSH MOUNTED, RATED AS NOTED RECESSED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE (N) UNIT PANELBOARD, FLUSH MOUNTED, RATED AS NOTED RECESSED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE UNIT PANELBOARD, FLUSH MOUNTED, RATED AS NOTED DUPLEX RECEPTACLE, 15A, 125V UNLESS NOTED OTHERWISE QUAD RECEPTACLE, 15A, 125V UNLESS NOTED OTHERWISE J JUNCTION BOX DUPLEX RECEPTACLE, 20A, 125V UNLESS NOTED OTHERWISE QUAD RECEPTACLE, 20A, 125V UNLESS NOTED OTHERWISE J JUNCTION BOX FH (E)WALL TO REMAIN (E)ONE-HOUR WALL (E)TWO HOUR WALL (N)PARTITION ONE-HOUR WALL TWO HOUR WALL PARTITION TYPE (N)WALL INFILL WALL LEGEND (EXISTING) DATA OUTLET TELEVISION OUTLET VOICE & DATA OUTLET DATA OUTLET TELEVISION OUTLET VOICE & DATA OUTLET DATA OUTLET TELEVISION OUTLET VOICE & DATA OUTLET REMAIN(REM) RELOCATE(RELO) REPLACE(REPLACE) ANNOTATION SYMBOLS WALL LEGEND (NEW) FH FH D.DIMENSIONS 1.DIMENSIONS ARE INDICATED TO THE CENTERLINE OF THE STRUCTURAL GRID, FACE OF CONCRETE WALL, NOMINAL FACE OF CMU WALL, FACE OF SHEATHING AT EXTERIOR AND FACE OF STUD AT INTERIORS, AS SCHEDULED, UNLESS OTHERWISE NOTED. 2.ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. 3.FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 4.VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - AFF. 5.CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC PANEL CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 6.DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, CLEARANCE, AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND COMPONENTS. DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE DRAWINGS. 7.WHERE DIMENSIONAL DISCREPANCIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY BEFORE PROCEEDING WITH THE WORK. D.TEMPORARY FACILITIES 1.THE CONTRACTOR SHALL MAKE ALL NECESSARY ARRANGEMENTS FOR CONSTRUCTION WATER, POWER, AND TOILET FACILITIES. 2.ALL COMBUSTIBLES CONSISTING OF BOXES, SCRAP LUMBER, ETC., ON THE CONSTRUCTION SITE SHALL BE CLEANED UP AND DISPOSED OF IN AN APPROVED MANNER ON A DAILY BASIS. 3.A MINIMUM OF ONE (1) 2A:10BC RATED EXTINGUISHER OR AS REQUIRED BY PUBLIC AGENCY HAVING JURISDICTION SHALL BE MAINTAINED AT THE JOB SITE. F.ACCESS DOORS & PANELS 1.CONTRACTOR SHALL PROVIDE ACCESS PANELS AS REQUIRED BY PLUMBING, FIRE SPRINKLER, MECHANICAL, ELECTRICAL AND OTHER INSTALLERS AS REQUIRED BY CODE. 2.PROVIDE RATED ACCESS PANEL @ ALL RATED WALL, FLOOR/CEILING, AND CEILING ROOF ASSEMBLIES. G. SPECIALTIES - FIRE EXTINGUISHERS 1.PROVIDE MIN. ONE (1) PORTABLE CLASS 2A: 10BC FIRE EXTINGUISHER. LOCATE WITHIN SEVENTY-FIVE (75) FEET FROM ANY POINT WITHIN THE TENANT SPACE. PROVIDE ADDITIONAL PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE DEPARTMENT FIELD INSPECTOR AND AS NOTED ON THE DRAWINGS. H.SIGNAGE 1.SIGN CONTRACTOR SHALL ACQUIRE SEPARATE BUILDING DEPARTMENT PERMITS FOR INSTALLATION OF ALL SIGNS AS REQUIRED BY LOCAL CODES. (N.I.C.). 2.GENERAL CONTRACTOR SHALL FURNISH AND INSTALL BLOCKING, ELECTRICAL JUNCTION BOX(ES), AND ACCESS PANELS. COORDINATE LOCATION(S) WITH SIGN CONTRACTOR AND ARCHITECT. 3.ROOM SIGNAGE SHALL BE BY CONTRACTOR BY STATE AND/OR LOCAL CODES. I.FIRE ASSEMBLIES 1.FIRE RESISTIVE FLOOR CEILING OR ROOF CEILINGS ASSEMBLIES SHALL BE PROVIDED, CONSTRUCTED, AND / OR MAINTAINED IN ACCORDANCE WITH SECTION 712 OF THE CALIFORNIA BUILDING CODE. 2.SHAFT ENCLOSURES: OPENINGS THROUGH FLOORS SHALL BE ENCLOSED IN A SHAFT ENCLOSURE OF FIRE RESISTIVE CONSTRUCTION IN ACCORDANCE WITH SECTION 713 OF THE CALIFORNIA BUILDING CODE. 3.PROVIDE FIRE STOPPING AT ALL THROUGH PENETRATIONS IN FIRE RATED WALL ASSEMBLIES, FLOOR/ CEILING ASSEMBLIES, CEILING / ROOF ASSEMBLIES, ETC. ALL FIRESTOPPING ASSEMBLIES SHALL HAVE U.L. LISTING OR EQUAL AND MEET THE REQUIREMENTS OF CALIFORNIA BUILDING CODE SECTION 711 & 712. J.PLUMBING 1.REFER TO PLUMBING DRAWINGS FOR ADDITIONAL NOTES. 2.AN APPROVED SEISMIC GAS SHUTOFF SHALL BE INSTALLED ON THE GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE GAS PIPES. 3.CONTRACTOR SHALL LABEL ALL SHUT OFF SUPPLY VALVES WITH THE AREAS/ITEMS IN WHICH THEY ARE SERVING. 4.WHERE IT HAS BEEN RECOMMENDED BY THE SOILS SURVEY REPORT TO PROVIDE PIPE PROTECTION FROM UNDERGROUND CORROSIVE SOIL(S), PIPES SHALL BE PROTECTED/ENCASED PER THE INSTALLATION/ENCASEMENT PORTIONS OF ASTM-74, ASTM D 2321 & AWWA C105 AS APPLIES. K.MECHANICAL 1.REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL NOTES. 2.COMBINATION FIRE AND SMOKE DAMPERS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR CEILINGS. CONTRACTOR SHALL PROVIDE REQUIRED CONSTRUCTION EVEN WHEN NOT SPECIFICALLY DETAILED. 3.CONTRACTOR SHALL UTILIZE BUILDING CONTRACTOR FOR STARTUP OF HVAC UNITS. L.FIRE SPRINKLERS (DESIGN BUILD) 1.THE BUILDING IS FULLY SPRINKLERED THROUGHOUT. THE DESIGN BUILD CONTRACTOR SHALL BE RESPONSIBLE FOR MODIFYING THE EXISTING SYSTEM TO ACCOMMODATE THE PROPOSED IMPROVEMENTS. 2.THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE AUTOMATIC FIRE SPRINKLER TO GOVERNING AGENCIES FOR APPROVAL PRIOR TO WORK IN THE FIELD. SHOP DRAWINGS SHALL BEAR STAMPED APPROVALS FROM ALL AUTHORIZED AGENCIES AND BY ANY OTHER AGENCIES WHOSE APPROVALS ARE REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. 3.AUTOMATIC FIRE SPRINKLERS MUST BE IN FULL OPERATIONAL USE AND "ON" PRIOR TO FIXTURIZATION OF TENNANT'S LEASE SPACE. 4.ALL SPRINKLER HEADS IN GYPSUM BOARD CEILINGS SHALL BE FULLY RECESSED TYPE. ESCUTCHEON COLOR SHALL BE SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD COLORS. 5.ALL SPRINKLER HEAD IN ACOUSTICAL CEILING TILE (OFFICE) SHALL BE SEMI-RECESSED TYPE - COLOR AS SELECTED BY THE ARCHITECT FROM MANUFACTURER'S STANDARD COLORS. M.ELECTRICAL 1.REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL NOTES. 2.ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING SITE CONDITIONS, SERVICE REQUIREMENTS, AND EXACT LOCATIONS OF SERVICE FACILITIES. 3.ELECTRICAL CONTRACTOR SHALL CHECK WITH OTHER TRADES FOR LOCATION OF EQUIPMENT WHICH REQUIRES ANY HOOK-UP, DISCONNECT SWITCHES, RELAYS, ETC. PRIOR TO ANY START OF WORK. 4.LOCATIONS SHOWN ON ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ELECTRICAL DRAWINGS. 5.EXIT SIGNS WHERE NOTED SHALL BE WORDED "EXIT" IN LETTERS SIX INCHES (6") HIGH AND SHALL CONFORM WITH GOVERNING BUILDING CODES AND REGULATIONS. PROVIDE ILLUMINATED EXIT SIGNS WHERE NOTED AND/OR REQUIRED BY CODE. ILLUMINATED EXIT SIGNS SHALL BE LIGHTED AND WIRED ON SEPARATE CIRCUIT. 6.EXITS SHALL BE ILLUMINATED AT ANYTIME THE BUILDING IS OCCUPIED WITH A LIGHT HAVING AN INTENSITY OF NOT LESS THAN ONE FOOT - CANDLE AT FLOOR LEVEL PER C.B.C. 7.ADDITIONAL DIRECTIONAL EXIT SIGNAGE MAY BE REQUIRED BY THE AHJ AT THE TIME OF FINAL INSPECTION. N.FIRE ALARM (DESIGN BUILD) 1.THE CONTRACTOR SHALL PROVIDE A COMPLETE FIRE ALARM DETECTION SYSTEM WITHIN THE TENANT SPACE AS AN EXTENSION OF THE LANDLORD'S BUILDING WIDE ADDRESSABLE FIRE ALARM SYSTEM. 2.THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE FIRE ALARM SYSTEM TO THE GOVERNING AGENCIES FOR APPROVAL PRIOR TO WORK IN THE FIELD. SHOP DRAWINGS SHALL BEAR STAMPED APPROVALS FOR THE AUTHORIZED AGENCIES AND BY ANY OTHER AGENCIES WHOSE APPROVALS ARE REQUIRED. PARTITION TYPE PARTITION TYPE SUSPENDED TILE CEILING AND GRID - - 18 A999 - - - - - OFFICE 999 000 SF - - 01 A 2 A-3 PH-00 - - - GENERAL NOTESLEGEND G201 GENERAL NOTES POWER DRIVEN FASTENERP.D.F. GYPSUM BOARD CEILING CAM CR PROTECT IN PLACEP.I.P. AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK G301 CALIFORNIA GREEN CHECK LIST 1.STORM WATER POLLUTION PREVENTION. NEWLY CONSTRUCTED PROJECTS AND ADDITIONS SHALL PREVENT THE POLLUTION OF STORM WATER RUNOFF FROM THE CONSTRUCTION ACTIVITIES. THE CITY’S LOCAL STORM WATER ORDINANCE REQUIREMENTS (NPDES). BEST MANAGEMENT PRACTICES (BMP’S) SHALL BE FOLLOWED TO PREVENT THE LOSS OF SOIL THROUGH WIND OR WATER EROSION BY IMPLEMENTING A COMBINATION OF EROSION AND SEDIMENT CONTROL. SOIL LOSS BMP AND GOOD HOUSEKEEPING BMP SHALL BE REVIEWED AND APPROVED BY THE CITY ENGINEERING SERVICES DIVISION OF PUBLIC WORKS PRIOR TO BEGINNING WORK. CALGREEN SEC 5.106.1.2. PROJECTS THAT DISTURB MORE THAN ONE ACRE OF LAND HAVE ADDITIONAL REQUIREMENTS. 4.ELECTRIC VEHICLE (EV) CHARGING. FOR NEW BUILDINGS, CONSTRUCTION SHALL PROVIDE THE ELECTRIC VEHICLE INFRASTRUCTURE TO EV CAPABLE PARKING SPACES TO FACILITATE ELECTRIC VEHICLE CHARGING AND SHALL BE IN ACCORDANCE WITH THE CALIFORNIA BUILDING AND ELECTRICAL CODES. AUTOMATED MECHANICAL CAR PARKING SYSTEMS ARE NOT REQUIRED TO COMPLY WITH THIS SECTION. THE NUMBER OF EV CAPABLE SPACES AND THE NUMBER OF EV CAPABLE SPACES WITH THE INSTALLATION OF ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE) SHALL BE AS FOLLOWS: 0 to 9 10 to 25 26 to 50 51 to 75 76 to 100 101 to 150 151 to 200 201 and over 0 4 8 13 17 25 35 20% of total* ACCESSIBLE EVCS. ARCHITECTURAL PLANS SHALL FURTHER SHOW ALL ACCESSIBILITY REQUIREMENTS FOR THE EV PARKING SPACES PER THE CALIFORNIA BUILDING CODE SECTION 11B-228.3 AND 11B-812. USE OF AUTOMATIC LOAD MANAGEMENT SYSTEMS (ALMS). ALMS SHALL BE PERMITTED FOR EVCS. WHEN ALMS IS INSTALLED, THE REQUIRED ELECTRICAL LOAD CAPACITY SPECIFIED IN SECTION 5.106.5.3.1 FOR EACH EVCS MAY BE REDUCED WHEN SERVICED BY AN EVSE CONTROLLED BY AN ALMS. DIVISION 5.2 – ENERGY EFFICIENCY SCOPE. THIS PROJECT SHALL COMPLY WITH ALL APPLICABLE ENERGY EFFICIENCY REQUIREMENTS AS SET FORTH IN THE 2022 CALIFORNIA ENERGY CODE. ENERGY CALCULATIONS AND FORMS SHALL BE INCLUDED AS PART OF THE PLANS AND DRAWINGS. DIVISION 5.1 – PLANNING & DESIGN SITE DEVELOPMENT (SEC. 5.106) 2.BICYCLE PARKING. SHORT-TERM AND LONG-TERM BICYCLE PARKING FACILITIES SHALL BE PROVIDED AS FOLLOWS (506.4): b.LONG-TERM BICYCLE PARKING SHALL BE PROVIDED FOR NEW BUILDINGS AND FOR ADDITIONS OR ALTERATIONS WITH 10 OR MORE TENANT-OCCUPANT PARKING SPACES, SHALL PROVIDE SECURE BICYCLE PARKING BASED ON 5% OF THE TENANT VEHICLE PARKING SPACES BEING ADDED WITH A MINIMUM OF ONE BICYCLE PARKING SPACE. ACCEPTABLE BICYCLE PARKING SHALL BE CONVENIENT FROM THE STREET AND SHALL MEET ONE OF THE FOLLOWING: 3.DESIGNATED PARKING FOR CLEAN AIR VEHICLES. CALGREEN SECTION 5.106.5.2 HAS BEEN DELETED AND DOES NOT REQUIRE PARKING FOR CLEAN-AIR VEHICLES. 5.LIGHT POLLUTION REDUCTION. FOR NEWLY CONSTRUCTED BUILDINGS, OUTDOOR LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED TO COMPLY WITH THE REQUIREMENTS OF CALGREEN SECTION 5.106.8. ELECTRICAL PLANS SHALL SHOW THE LIGHT POLLUTION REDUCTION REQUIREMENTS. 6.GRADING AND PAVING. FOR NEW BUILDINGS, AND FOR ADDITIONS AND ALTERATIONS THAT ALTER THE DRAINAGE PATH: CONSTRUCTION PLANS SHALL INDICATE HOW SITE GRADING OR A DRAINAGE SYSTEM WILL MANAGE ALL SURFACE WATER FLOWS TO KEEP WATER FROM ENTERING BUILDINGS. DIVISION 5.3 – WATER EFFICIENCY AND CONSERVATION 7.WATER METERS. FOR NEW BUILDINGS OR ADDITIONS LARGER THAN 50,000 SQUARE FEET, SEPARATE SUBMETERS SHALL BE INSTALLED AS FOLLOWS: b.A SEPARATE SUBMETER OR METERING DEVICE SHALL BE PROVIDED FOR EXCESS CONSUMPTION BY ANY TENANT WITHIN A NEW BUILDING OR ADDITION THAT IS PROJECTED TO CONSUME MORE THAN 1,000 GALLONS PER DAY. a.EACH TENANT SPACE WITHIN THE BUILDING PROJECTED TO CONSUME MORE THAN 100 GALLONS PER DAY, INCLUDING, BUT NOT LIMITED TO LAUNDRY OR CLEANERS, RESTAURANT OR FOOD SERVICE, MEDICAL OR DENTAL OFFICE, LABORATORY, OR BEAUTY SALON OR BARBER SHOP. 8.WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. ALL NEW PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND SHOWERHEADS) IN NEW BUILDINGS AND AREAS OF ADDITIONS OR ALTERATIONS, SHALL COMPLY WITH THE FOLLOWING MAXIMUM FLOW RATES: PLUMBING PLANS SHALL SHOW ALL INDOOR WATER EFFICIENCY FEATURES OF CALGREEN SECTION 5.303 10.COMMERCIAL KITCHEN EQUIPMENT. ALL NEW PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH THE MAXIMUM FLOW RATES AS FOLLOWS: DIVISION 5.4 – MATERIAL CONSERVATION AND RESOURCE EFFICIENCY 12.WEATHER PROTECTION. PROVIDE A WEATHER-RESISTANT EXTERIOR WALL AND FOUNDATION ENVELOPE AS REQUIRED BY THE CALIFORNIA BUILDING CODE SECTION 1404.2 (WEATHER PROTECTION) AND THE CALIFORNIA ENERGY CODE SECTION 150. 13.MOISTURE CONTROL. PROVIDE MOISTURE CONTROL MEASURES BY THE FOLLOWING METHODS: a.LANDSCAPE IRRIGATION SPRINKLER SYSTEMS SHALL BE DESIGNED TO PREVENT SPRAY ON STRUCTURES. b.PRIMARY EXTERIOR DOORS SHALL BE COVERED TO PREVENT WATER INTRUSION BY USING NONABSORBENT FLOOR AND WALL FINISHES WITHIN 2-FEET AROUND SUCH OPENINGS PLUS AT LEAST ONE OF THE FOLLOWING: i.AN INSTALLED AWNING AT LEAST 4 FEET IN DEPTH. ii.A ROOF OVERHANG AT LEAST 4 FEET IN DEPTH. iii.THE DOOR IS RECESSED AT LEAST 4 FEET. iv.OTHER EQUIVALENT PROTECTION. C.INSTALL FLASHINGS INTEGRATED WITH A DRAINAGE PLANE. PLANS SHALL SHOW DETAILS FOR WEATHER PROTECTION AND MOISTURE CONTROL PER CALGREEN SEC 5.407. 14.CONSTRUCTION WASTE MANAGEMENT. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65% OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH THE CITY OF ARCADIA CONSTRUCTION AND DEMOLITION MATERIALS MANAGEMENT PLAN (CDMMP) ORDINANCE. A CITY APPROVED WASTE MANAGEMENT COMPANY/HAULER SHALL BE USED FOR RECYCLING OF CONSTRUCTION WASTE. DOCUMENTATION OF COMPLIANCE SHALL BE PROVIDED TO THE CITY’S ENVIRONMENTAL SERVICES DIVISION. 15.EXCAVATED SOIL AND LAND CLEARING DEBRIS. 100% OF TREES, STUMPS, ROCKS AND ASSOCIATED VEGETATION AND SOILS FROM LAND CLEARING SHALL BE REUSED OR RECYCLED. CONTAMINATED SOIL OR MATERIALS ARE NOT REQUIRED TO BE REUSED OR RECYCLED. 16.RECYCLING BY OCCUPANTS. PROVIDE READILY ACCESSIBLE AREAS SERVING THE ENTIRE BUILDING FOR THE COLLECTION OF NON-HAZARDOUS MATERIALS FOR RECYCLING, INCLUDING (BUT NOT LIMITED TO) PAPER, CORRUGATED CARDBOARD, GLASS, PLASTICS, ORGANIC WASTE, AND METALS. THE PROJECT SHALL ALSO COMPLY WITH THE CITY’S RECYCLING ORDINANCE. 17.COMMISSIONING. FOR NEW BUILDINGS 10,000 SQUARE FEET AND OVER, BUILDING COMMISSIONING SHALL BE INCLUDED IN THE DESIGN AND CONSTRUCTION PROCESSES OF THE BUILDING PROJECT TO VERIFY THAT THE BUILDING SYSTEMS AND COMPONENTS MEET THE OWNER’S OR OWNER REPRESENTATIVE’SPROJECT REQUIREMENTS. COMMISSIONING SHALL BE PERFORMED IN ACCORDANCE WITH CALGREEN CODE SECTION 5.410.2 BY TRAINED PERSONNEL WITH EXPERIENCE ON PROJECTS OF COMPARABLE SIZE AND COMPLEXITY. COMMISSIONING REQUIREMENTS TO INCLUDE: 18.TESTING AND ADJUSTING. NEW BUILDINGS LESS THAN 10,000 SQUARE FEET OR NEW SYSTEMS THAT SERVE AN ADDITION OR ALTERATION, SHALL BE TESTED AND ADJUSTED AS FOLLOWS: a.PROCEDURES. TESTING AND ADJUSTING SHALL BE IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS AND APPLICABLE STANDARDS ON EACH SYSTEM. b.HVAC BALANCING. IN ADDITION TO TESTING AND ADJUSTING, HVAC SYSTEMS SHALL BE ADJUSTED AND BALANCED BEFORE THE SYSTEM IS OPERATED FOR USE. c.REPORTING. AFTER COMPLETION OF ALL TESTING, ADJUSTING AND BALANCING, A FINAL REPORT OF TESTING SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES SHALL BE GIVING TO THE OWNER. d.OPERATION AND MAINTENANCE MANUAL. THE BUILDING OWNER OR REPRESENTATIVE SHALL BE PROVIDED WITH A DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTIES/WARRANTIES FOR EACH SYSTEM. THE MANUAL SHALL INCLUDE A COPY OF ALL INSPECTION VERIFICATIONS AND REPORTS. DIVISION 5.5 – ENVIRONMENTAL QUALITY 19.FIREPLACES. ANY INSTALLED GAS FIREPLACE SHALL BE DIRECT-VENT SEALED COMBUSTION TYPE. NEW PERMANENTLY INSTALLED WOOD BURNING DEVICES ARE PROHIBITED PER SCAQMD RULE 445. 20.TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY. 21.PROTECTION OF HVAC EQUIPMENT AND DUCT SYSTEMS. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HVAC EQUIPMENT, ALL DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEETMETAL OR OTHER METHOD TO PREVENT DUST OR DEBRIS FROM ENTERING THE SYSTEM. 22.FINISH MATERIAL POLLUTANT CONTROL, SHALL COMPLY AS FOLLOWS: a.ADHESIVES, SEALANTS AND CAULKS USED ON THIS PROJECT SHALL COMPLY WITH SCAQMD RULE 1168 FOR VOC LIMITS AND TOXIC COMPOUNDS. AEROSOL ADHESIVES, SEALANTS AND CAULKS SHALL COMPLY WITH STATEWIDE VOC STANDARDS. b.PAINTS AND COATINGS SHALL COMPLY WITH VOC LIMITS IN TABLE 1 OF THE ARB ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, AS SHOWN IN CALGREEN TABLE 5.504.4.3. c.AEROSOL PAINTS AND COATINGS SHALL MEET THE PWMIR LIMITS FOR ROC IN SECTION 94522(A)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES, IN SECTIONS 94522(C)(2) AND (D)(2) OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520 d.CARPET SYSTEMS. ALL CARPETING SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PLUS PROGRAM OR EQUIVALENT PER CALGREEN SECTION 5.504.4.4. CARPET CUSHIONS SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. ADHESIVES SHALL COMPLY WITH VOC LIMITS IN CALGREEN TABLE 5.504.4.1. e.COMPOSITE WOOD PRODUCTS. HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN ARB’S AIR TOXICS CONTROL MEASURE (ATCM) FOR COMPOSITE WOOD AS SHOWN IN CALGREEN TABLE 5.504.4.5. VERIFICATION OF COMPLIANCE SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. f.RESILIENT FLOORING. WHERE INSTALLED, 80% OF THE FLOOR AREA RECEIVING RESILIENT FLOORING SHALL MEET AT LEAST ONE OF THE STANDARDS LISTED IN CALGREEN SECTION 5.504.4.6. DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT RESILIENT FLOORING MATERIALS MEET THE POLLUTANT EMISSION LIMITS. g.THERMAL INSULATION SHALL MEET AT LEAST ONE OF THE STANDARDS LISTED IN CALGREEN SECTION 5.504.4.7. DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT THERMAL INSULATION MATERIALS MEET THE POLLUTANT EMISSION LIMITS. h.ACOUSTICAL CEILINGS AND WALL PANELS SHALL MEET AT LEAST ONE OF THE STANDARDS LISTED IN CALGREEN SECTION 5.504.4.8. DOCUMENTATION SHALL BE PROVIDED VERIFYING THAT ACOUSTICAL FINISH MATERIALS MEET THE POLLUTANT EMISSION LIMITS. 23.FILTERS. IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT PROVIDES AT LEAST A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 13. FILTERS SHALL BE CLEARLY LABELED BY THE MANUFACTURER INDICATING THE MERV RATING. a.WATER CLOSETS: 1.28 GALLONS PER FLUSH. b.URINALS: MAXIMUM 0.125 GALLONS PER FLUSH FOR WALL-MOUNTED. OTHER URINALS: 0.5 GALLONS PER FLUSH. c.SINGLE SHOWERHEADS: MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 80 PSI. d.MULTIPLE SHOWERHEADS SERVING ONE SHOWER: COMBINED FLOW RATE OF ALL SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 80 PSI. e.LAVATORY FAUCETS: 0.5 GALLONS PER MIN. AT 60 PSI. f.KITCHEN FAUCETS: 1.8 GAL PER MIN. AT 60 PSI. g.WASH FOUNTAINS: 1.8 GAL PER MIN. /20 [RIM SPACE AT 60 PSI]. h.METERING FAUCETS: 0.20 GALLONS PER CYCLE. 24.TOBACCO SMOKE CONTROL. WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, SIGNAGE SHALL BE INSTALLED PROHIBITING SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES AND OPERABLE WINDOWS. 25.INDOOR MOISTURE CONTROL. BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF THE CALIFORNIA BUILDING CODE, SECTION 1202 (VENTILATION) AND CHAPTER 14 (EXTERIOR WALLS). 26.CARBON DIOXIDE MONITORING. FOR BUILDINGS OR ADDITIONS EQUIPPED WITH DEMAND CONTROL VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS SHALL BE SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CALIFORNIA ENERGY CODE, SECTION 120.1(C)(4). CARBON DIOXIDE MONITORING IN EACH PUBLIC K-12 SCHOOL CLASSROOM SHALL BE EQUIPPED WITH A CARBON DIOXIDE MONITOR OR SENSOR THAT COMPLIES WITH THE REQUIREMENTS OF CALGREEN NEW SECTION 5.506.3. 27.ACOUSTICAL CONTROL. NEW BUILDINGS, ADDITIONS, AND ALTERATIONS, LOCATED WITHIN THE 65 CNEL OR LDN NOISE CONTOUR OF A FREEWAY, EXPRESSWAY, RAILROAD, INDUSTRIAL OR OTHER NOISE SOURCE AS DETERMINED BY THE NOISE ELEMENT OF THE GENERAL PLAN, SHALL EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH SOUND TRANSMISSION CLASS (STC) VALUES DETERMINED IN ACCORDANCE WITH ASTM E90 AND ASTM E413 OR OUTDOOR-INDOOR SOUND TRANSMISSION CLASS (OITC) DETERMINED IN ACCORDANCE WITH ASTM E1332, USING EITHER THE PRESCRIPTIVE OR PERFORMANCE METHOD AS FOLLOWS: a.PRESCRIPTIVE METHOD FOR EXTERIOR NOISE SOURCES. WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE SHALL MEET A STC RATING OF AT LEAST 50 OR AN OITC RATING OF NO LESS THAN 40. EXTERIOR WINDOWS SHALL MEET A STC RATING OF AT LEAST 40 OR AN OITC RATING OF AT LEAST 30. b.PERFORMANCE METHOD FOR EXTERIOR NOISE SOURCES. WALL AND ROOF-CEILING ASSEMBLIES EXPOSED TO THE NOISE SOURCE SHALL BE CONSTRUCTED TO PROVIDE AN INTERIOR NOISE ENVIRONMENT THAT DOES NOT EXCEED AN HOURLY EQUIVALENT NOISE LEVEL (LDN -1HR) OF 50 DBA IN OCCUPIED AREAS DURING ANY HOUR OF OPERATION. AN ACOUSTICAL ANALYSIS DOCUMENTING COMPLYING INTERIOR SOUND LEVELS SHALL BE PREPARED BY PERSONNEL APPROVED BY THE ARCHITECT OR ENGINEER OF RECORD. ACOUSTICAL CONTROL DOES NOT APPLY TO BUILDINGS WITH FEW OR NO OCCUPANTS OR WHERE OCCUPANTS ARE NOT LIKELY TO BE AFFECTED BY EXTERIOR NOISE AS DETERMINED BY THE ENFORCING AGENCY, SUCH AS FACTORIES, WAREHOUSES, PARKING STRUCTURES AND UTILITY BUILDINGS. 28.OUTDOOR AIR QUALITY. OZONE DEPLETION AND GREENHOUSE GAS REDUCTIONS. HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT SHALL NOT CONTAIN CFCS OR HALONS. 29.SUPERMARKET REFRIGERANT LEAK REDUCTION. NEW AND REPLACEMENT REFRIGERATION SYSTEMS WHEN INSTALLED IN RETAIL FOOD STORES 8,000 SQUARE FEET OR MORE CONDITIONED AREA, AND THAT UTILIZE REFRIGERATED DISPLAY CASES, OR WALK-IN COOLERS OR FREEZERS CONNECTED TO REMOTE COMPRESSOR OR CONDENSING UNITS, SHALL COMPLY WITH THE PROVISIONS OF CALGREEN SECTIONS 5.508.2 THROUGH 5.508.2.6, TO REDUCE THE POTENTIAL FOR REFRIGERANT LEAKAGE. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS CHAPTER 7 1.GENERAL. NEW BUILDINGS SHALL COMPLY WITH THE REQUIREMENTS OF CALGREEN CHAPTER 7. 2.INSTALLER TRAINING. HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED BY A NATIONALLY OR REGIONALLY RECOGNIZED TRAINING OR CERTIFICATION PROGRAM AS OUTLINED IN CALGREEN SECTION 702.1. 3.SPECIAL INSPECTION. WHEN REQUIRED BY THE ENFORCING AGENCY, THE OWNER OR THE RESPONSIBLE ENTITY ACTING AS THE OWNER’S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PROVIDE INSPECTION OR OTHER DUTIES NECESSARY TO SUBSTANTIATE COMPLIANCE WITH THE CALGREEN CODE. SPECIAL INSPECTORS SHALL BE REGISTERED WITH THE CITY OF ARCADIA BUILDING & SAFETY DIVISION PRIOR TO PERFORMING ANY SPECIAL INSPECTIONS OF ANY COMPONENT OR SYSTEM REQUIRED. SPECIAL INSPECTORS SHALL BE INDEPENDENT ENTITIES WITH NO FINANCIAL INTEREST IN THE MATERIALS OR THE PROJECT THEY ARE INSPECTING. 4.VERIFICATIONS. DOCUMENTATION USED TO SHOW COMPLIANCE WITH THIS CODE SHALL INCLUDE BUT IS NOT LIMITED TO: CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, INSPECTION REPORTS, OR OTHER METHODS ACCEPTABLE TO THE CITY OF ARCADIA Compliance Statement AS THE DESIGN PROFESSIONAL OR DESIGNER OF RECORD FOR THIS PROJECT, I CERTIFY THAT THIS PROJECT WILL COMPLY WITH ALL APPLICABLE PROVISIONS OF THE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN CODE). Signature Print Name Date Revision Date 1/1/23 11.OUTDOOR WATER USE. LANDSCAPE AREAS SHALL FOLLOW THE MANDATORY MODEL WATER EFFICIENCY LANDSCAPE ORDINANCE (MWELO) CONTAINED WITHIN CHAPTER 2.7, DIVISION 2, TILE 23, CALIFORNIA CODE OF REGULATIONS. LANDSCAPE PLANS SHALL SHOW ALL OUTDOOR WATER EFFICIENCY FEATURES OF CALGREEN SECTION 5.304. a.FOOD WASTE DISPOSERS: DISPOSER SHALL EITHER BE 1 GPM WHEN THE DISPOSER IS NOT IN USE OR SHALL AUTOMATICALLY SHUT OFF AFTER NO MORE THAN 10 MINUTES OF INACTIVITY. DISPOSER SHALL USE NO MORE THAN 8 GPM OF WATER. TABLE 5.504.4.1 - ADHESIVE VOC LIMIT 1,2 LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVES 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168, www.arb.ca.gov/DRDB/SC/CURHTML/R1168.PDF TABLE 5.504.4.2 - SEALANT VOC LIMIT LESS WATER AND LESS EXEMPT COMPOUNDS IN GRAMS PER LITER SEALANTS CURRENT VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NONPOROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 NOTE: FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THESE TABLES, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 5.504.4.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY CURRENT VOC LIMIT FLAT COATINGS 50 NONFLAT COATINGS 100 NONFLAT HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH-TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS: CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. TABLE 5.504.4.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIFORNIA CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16 INCHES (8 MM). SCALE:26 CAL GREEN NOTES NTS SCALE:11 CAL GREEN TABLES NTS SCALE:8 MANDATORY REQUIREMENTS CHECKLIST NTS a.SHORT-TERM BICYCLE PARKING SHALL BE PROVIDED FOR ALL NEW PROJECTS AND FOR ADDITIONS OR ALTERATIONS WITH 10 OR MORE NEW PARKING SPACES, AS FOLLOWS: i.FOR PROJECTS THAT GENERATE VISITOR (CUSTOMER) TRAFFIC; PROVIDE PERMANENTLY ANCHORED VISITOR BICYCLE RACKS WITHIN 200 FEET OF THE VISITORS’ ENTRANCE, READILY VISIBLE TO PASSERS-BY, BASED ON 5% OF THE NEW VISITOR VEHICLE PARKING SPACES WITH A MINIMUM OF ONE TWO-BIKE RACK. i.COVERED, LOCKABLE ENCLOSURES WITH PERMANENTLY ANCHORED BICYCLE RACKS; OR ii.LOCKABLE BICYCLES ROOMS WITH PERMANENTLY ANCHORED RACKS; OR iii.LOCKABLE, PERMANENTLY ANCHORED BICYCLE LOCKERS. SHOW LOCATION OF THE BICYCLE PARKING ON THE SITE/FLOOR PLANS AND PROVIDE DETAILS FOR SECURE BICYCLE STORAGE. 0 0 2 3 4 6 9 25% of EV capable spaces* * ROUND UP TO THE NEAREST WHOLE NUMBER NUMBER OF REQUIRED EV CAPABLE SPACES NUMBER OF EV CAPABLE SPACES WITH EVSE TOTAL NUMBER OF ACTUAL PARKING SPACES EV CAPABLE SPACES. TO FACILITATE THE INSTALLATION OF EVSE, THE INFRASTRUCTURE SHALL BE INSTALLED AT THE TIME OF CONSTRUCTION. PLANS AND ELECTRICAL CALCULATIONS SHALL COMPLY WITH ALL THE DETAILED INFRASTRUCTURE CONSTRUCTION REQUIREMENTS FOR THE FUTURE INSTALLATION OF EVSE AS LISTED IN CALGREEN SECTION 5.106.5.3.1. ELECTRIC VEHICLE CHARGING STATIONS (EVCS). EV CAPABLE SPACES PROVIDED WITH EVSE CREATES EVCS AS REQUIRED IN COLUMN 3 SHOWN ABOVE. EVCS MAY BE PROVIDED WITH EVSE IN ANY COMBINATION OF LEVEL 2 AND DIRECT CURRENT FAST CHARGING (DCFC) EXCEPT THAT AT LEAST ONE LEVEL 2 EVSE SHALL BE PROVIDED. THE INSTALLATION OF EACH DCFC EVSE SHALL BE PERMITTED TO REDUCE THE MINIMUM NUMBER OF REQUIRED EV CAPABLE SPACES WITHOUT EVSE BY FIVE AND REDUCE PROPORTIONALLY THE REQUIRED ELECTRICAL LOAD CAPACITY TO THE SERVICE PANEL OR SUBPANEL. 9.OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. NONRESIDENTIAL DEVELOPMENTS SHALL COMPLY WITH THE LOCAL WATER EFFICIENT LANDSCAPE ORDINANCE OR THE CURRENT CALIFORNIA DEPARTMENT OF WATER RESOURCES MODEL WATER EFFICIENCY LANDSCAPE ORDINANCE (MWELO), WHICHEVER IS MORE STRINGENT. EACH OF THE ABOVE ITEMS SHALL INDIVIDUALLY COMPLY WITH CALGREEN SECTIONS 5.410.2.1 THROUGH 5.410.2.6. COMMISSIONING IS NOT REQUIRED FOR THE FOLLOWING: a.UNCONDITIONED WAREHOUSES OF ANY SIZE. b.AREAS LESS THAN 10,000 SQUARE FEET USED FOR OFFICES OR OTHER CONDITIONED ACCESSORY SPACES WITHIN UNCONDITIONED WAREHOUSES. c.TENANT IMPROVEMENTS LESS THAN 10,000 S.F. AND NOT THE INITIAL TENANT TO THE SPACE. d.OPEN PARKING GARAGES, OF ANY SIZE, WITHIN A STRUCTURE. a.OWNER’S OR OWNER REPRESENTATIVE’S PROJECT REQUIREMENTS. b.BASIS OF DESIGN. c.COMMISSIONING MEASURES SHOWN IN THE CONSTRUCTION DOCUMENTS. d.COMMISSIONING PLAN. e.FUNCTIONAL PERFORMANCE TESTING. f.DOCUMENTATION AND TRAINING. g.COMMISSIONING REPORT. INTERIOR SOUND TRANSMISSION. WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING TENANT SPACES AND TENANT SPACES FROM PUBLIC PLACES SHALL HAVE AN STC OF AT LEAST 40. JOHNNY C. LU 08/11/2025 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - MANDATORY REQUIREMENTS CHECKLIST: NEWLY CONSTRUCTED NON-RESIDENTIAL BUILDINGS ITEM #CODE SECTION REQUIREMENT REFERENCE SHEET # or N/A COMMENTS E.G. NOTES # 1 5.106.1 STORM WATER POLLUTION PREVENTION G301 NOTE 1 2 5.106.4.1.1 SHORT-TERM BICYCLE PARKING G301 NOTE 2A 2 5.106.4.1.2 LONG-TERM BICYCLE PARKING G301 NOTE 2B 3 5.106.5.2 DESIGNATED PARKING FOR CLEAN AIR VEHICLES NA NA 4 5.106.5.3 ELECTRIC VEHICLE CHARGING G301 NOTE 4 5 5.106.8 LIGHT POLLUTION REDUCTION G301 NOTE 5 6 5.106.10 GRADING AND PAVING G301 NOTE 6 7 5.303.1.1 NEW BUILDINGS IN EXCESS OF 50,000 SQ. FT.G301 NOTE 7 8 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS G301 NOTE 8 10 5.303.4 COMMERCIAL KITCHEN EQUIPMENT G301 NOTE 10 11 5.304.1 OUTDOOR WATER USE G301 NOTE 11 12 5.407.1 WEATHER PROTECTION G301 NOTE 12 13 5.407.2 MOISTURE CONTROL G301 NOTE 13 14 5.408.1 CONSTRUCTION WASTE MANAGEMENT G301 NOTE 14 15 5.408.3 EXCAVATED SOIL AND LAND CLEARING DEBRIS G301 NOTE 15 16 5.410.1 RECYCLING BY OCCUPANTS G301 NOTE 16 17 5.410.2 COMMISSIONING (>10,000 SQ. FT.)G301 NOTE 17 18 5.410.4 TESTING AND ADJUSTING (<10,000 SQ. FT.)G301 NOTE 18 19 5.503.1 FIREPLACE AND WOOD STOVES G301 NOTE 19 20 5.504.1 TEMPORARY VENTILATION G301 NOTE 20 21 5.504.3 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION G301 NOTE 21 22 5.504.4 FINISH MATERIAL POLLUTANT CONTROL G301 NOTE 22 23 5.504.5.3 FILTERS G301 NOTE 23 24 5.504.7 ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL G301 NOTE 24 25 5.505.1 INDOOR MOISTURE CONTROL G301 NOTE 25 26 5.506.2 CARBON DIOXIDE MONITORING G301 NOTE 26 27 5.507.4 ACOUSTICAL CONTROL G301 NOTE 27 28 5.508.1 OZONE DEPLETIONS AND GREENHOUSE GAS REDUCTION G301 NOTE 28 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK G401 ACCESSIBILITY NOTES A.APPLICATION AND ADMINISTRATION 1.PUBLIC ACCOMMODATIONS SHALL MAINTAIN IN OPERABLE WORKING CONDITION THOSE FEATURES OF FACILITIES AND EQUIPMENT THAT ARE REQUIRED TO BE ACCESSIBLE TO AND USEABLE BY PERSONS WITH DISABILITIES. ISOLATED OR TEMPORARY INTERRUPTIONS IN SERVICE OR ACCESSIBILITY DUE TO MAINTENANCE OR REPAIRS SHALL BE PERMITTED. §11B- 108 2.WHEN ALTERATIONS OR ADDITIONS ARE MADE TO EXISTING BUILDINGS OR FACILITIES, AN ACCESSIBLE PATH OF TRAVEL TO THE SPECIFIC AREA OF ALTERATION OR ADDITION SHALL BE PROVIDED UNLESS OTHERWISE EXEMPT. §11B-202.4 3.PRIMARY ACCESSIBLE PATH OF TRAVEL SHALL INCLUDE A PRIMARY ENTRANCE TO THE BUILDING OR FACILITY; TOILET AND BATHING FACILITIES SERVING THE AREA; DRINKING FOUNTAINS SERVING THE AREA; PUBLIC TELEPHONES SERVING THE AREA, AND SIGNS. §11B-202. 4.WHEN THE ADJUSTED CONSTRUCTION COST IS LESS THAN OR EQUAL TO THE CURRENT VALUATION THRESHOLD $147,863.00, THE COST OF COMPLIANCE WITH THE PRIMARY ACCESSIBLE PATH OF TRAVEL REQUIREMENTS IS LIMITED TO 20 PERCENT OF THE ADJUSTED CONSTRUCTION COST OF ALTERATIONS, STRUCTURAL REPAIRS OR ADDITIONS PRESENTLY PLANNED AND THOSE DURING THE PRECEDING THREE-YEAR PERIOD. §11B-202.4 5.ADJUSTED CONSTRUCTION COST OF ALTERATIONS, STRUCTURAL REPAIRS OR ADDITIONS DOES NOT INCLUDE THE COST OF ALTERATIONS TO PATH OF TRAVEL ELEMENTS. §11B-202.4 6.IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS IN THE FOLLOWING ORDER: (1) AN ACCESSIBLE ENTRANCE; (2) AN ACCESSIBLE ROUTE TO THE ALTERED AREA; (3) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE ACCESSIBLE UNISEX RESTROOM; (4) ACCESSIBLE TELEPHONES; (5) ACCESSIBLE DRINKING FOUNTAINS; AND (6) WHEN POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH AS PARKING, SIGNS, STORAGE AND ALARMS. §11B-202.4 7.ALTERATIONS TO A QUALIFIED HISTORIC BUILDING OR FACILITY SHALL COMPLY WITH CHAPTER 11B UNLESS IT WILL THREATEN OR DESTROY THE HISTORICAL SIGNIFICANCE OR CHARACTER-DEFINING FEATURES OF THE BUILDING OR PROPERTY. IN THOSE CASES, ALTERNATIVE PROVISIONS SHALL BE APPLIED ON AN ITEM-BY- ITEM OR CASE-BY-CASE BASIS WITH SUFFICIENT WRITTEN DOCUMENTATION. §11B-202.5, SHBC 8-602 8.NOTE ON PLAN: PUBLIC ACCOMMODATIONS SHALL MAINTAIN IN OPERABLE WORKING CONDITION THOSE FEATURES OF FACILITIES AND EQUIPMENT THAT ARE REQUIRED TO BE ACCESSIBLE TO AND USEABLE BY PERSONS WITH DISABILITIES. ISOLATED OR TEMPORARY INTERRUPTIONS IN SERVICE OR ACCESSIBILITY DUE TO MAINTENANCE OR REPAIRS SHALL BE PERMITTED. §11B-108 B.BUILDING BLOCKS FLOOR OR GROUND SURFACES 1.FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT. §11B-302.1 2.CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE ½ INCH MAXIMUM. §11B-302.2, FIGURE 11B-302.2 CHANGES IN LEVEL 3.VERTICAL CHANGES IN LEVEL FOR FLOOR OR GROUND SURFACES MAY BE ¼ INCH HIGH MAXIMUM AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL GREATER THAN ¼ INCH AND NOT EXCEEDING ½ INCH IN HEIGHT SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. §11B-303, FIGURES 11B-303.2 & 11B-303.3 4.CHANGES IN LEVEL GREATER THAN ½ INCH IN HEIGHT SHALL BE RAMPED AND SHALL COMPLY WITH THE REQUIREMENTS OF 11B-405 RAMPS OR 11B-406 CURB RAMPS AS APPLICABLE. §11B-303 5.ABRUPT CHANGES IN LEVEL EXCEEDING 4 INCHES IN A VERTICAL DIMENSION BETWEEN WALKS, SIDEWALKS OR OTHER PEDESTRIAN WAYS AND ADJACENT SURFACES OR FEATURES SHALL BE IDENTIFIED BY WARNING CURBS AT LEAST 6 INCHES IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE OR BY GUARDS OR HANDRAILS WITH A GUIDE RAIL CENTERED 2 INCHES MINIMUM AND 4 INCHES MAXIMUM ABOVE THE SURFACE OF THE WALK OR SIDEWALK. THESE REQUIREMENTS DO NOT APPLY BETWEEN A WALK OR SIDEWALK AND AN ADJACENT STREET OR DRIVEWAY. §11B-303.5 TURNING SPACE 6.CIRCULAR TURNING SPACES SHALL BE A SPACE OF 60 INCHES DIAMETER MINIMUM AND MAY INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH 11B-306 KNEE AND TOE CLEARANCE. §11B-304.3.1 7.T-SHAPED TURNING SPACES SHALL BE A T-SHAPED SPACE WITHIN A 60 INCH SQUARE MINIMUM WITH ARMS AND BASE 36 INCHES WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES MINIMUM. §11B-304.3.2, FIGURE 11B-304.3.2 KNEE AND TOE CLEARANCE 8.FOR LAVATORIES AND BUILT-IN DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, TOE CLEARANCE SHALL BE PROVIDED THAT IS 30 INCHES IN WIDTH AND 9 INCHES IN HEIGHT ABOVE THE FINISH FLOOR OR GROUND FOR A DEPTH OF 19 INCHES MINIMUM. §11B-306.2.1 9.TOE CLEARANCE SHALL EXTEND 19 INCHES MAXIMUM UNDER LAVATORIES FOR TOILET AND BATHING FACILITIES AND 25 INCHES MAXIMUM UNDER OTHER ELEMENTS. §11B-306.2.2 10.AT LAVATORIES IN TOILET AND BATHING FACILITIES, KNEE CLEARANCE SHALL BE PROVIDED THAT IS 30 INCHES IN WIDTH FOR A DEPTH OF 11 INCHES AT 9 INCHES ABOVE THE FINISH FLOOR OR GROUND AND FOR A DEPTH OF 8 INCHES AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND INCREASING TO 29 INCHES HIGH MINIMUM ABOVE THE FINISH FLOOR OR GROUND AT THE FRONT EDGE OF A COUNTER WITH A BUILT-IN LAVATORY OR AT THE FRONT EDGE OF A WALL-MOUNTED LAVATORY FIXTURE. §11B- 306.3.3, FIGURE 11B-306.3(C) 11.AT DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, KNEE CLEARANCE SHALL BE PROVIDED THAT IS 30 INCHES IN WIDTH AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND FOR A DEPTH OF AT LEAST 19 INCHES. §11B-306. PROTRUDING OBJECTS 12.EXCEPT FOR HANDRAILS, OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND LESS THAN 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL PROTRUDE NO MORE THAN 4 INCHES HORIZONTALLY INTO THE CIRCULATION PATH. HANDRAILS MAY PROTRUDE 4½ INCHES MAXIMUM. §11B-307.2, FIGURE 11B-307.2 13.FREESTANDING OBJECTS MOUNTED ON POSTS OR PYLONS SHALL OVERHANG CIRCULATION PATHS NO MORE THAN 12 INCHES WHEN LOCATED FROM 27 TO 80 INCHES ABOVE THE FINISH FLOOR OR GROUND. §11B-307.3, FIGURE 11B-307.3(A) 14.PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES. §11B-307.5 15.LOWEST EDGE OF A SIGN OR OTHER OBSTRUCTION, WHEN MOUNTED BETWEEN POSTS OR PYLONS SEPARATED WITH A CLEAR DISTANCE GREATER THAN 12 INCHES, SHALL BE LESS THAN 27 INCHES OR MORE THAN 80 INCHES ABOVE THE FINISH FLOOR OR GROUND. §11B-307.3, FIGURE 11B-307.3(B) 16.VERTICAL CLEARANCE SHALL BE AT LEAST 80 INCHES HIGH ON CIRCULATION PATHS EXCEPT AT DOOR CLOSERS AND DOOR STOPS, WHICH MAY BE 78 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-307.4 17.GUARDRAILS OR OTHER BARRIERS WITH A LEADING EDGE LOCATED 27 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE ON CIRCULATION PATHS IS LESS THAN 80 INCHES HIGH. §11B-307.4, FIGURE 11B-307.4 18.WHERE A GUY SUPPORT IS USED WITHIN EITHER THE WIDTH OF A CIRCULATION PATH OR 24 INCHES MAXIMUM OUTSIDE OF A CIRCULATION PATH, A VERTICAL GUY BRACE, SIDEWALK GUY OR SIMILAR DEVICE SHALL BE USED TO PREVENT A HAZARD OR AN OVERHEAD OBSTRUCTION. §11B-307.4.1, FIGURE 11B-307.4.1 REACH RANGES 19.ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. §11B-308.1.1 20.ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. §11B-308.1.2. 21.HIGH FORWARD REACH THAT IS UNOBSTRUCTED SHALL BE 48 INCHES MAXIMUM AND THE LOW FORWARD REACH SHALL BE 15 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-308.2.1, FIGURE 11B-308.2.1 22.HIGH FORWARD REACH SHALL BE 48 INCHES MAXIMUM WHERE THE REACH DEPTH IS 20 INCHES OR LESS AND 44 INCHES MAXIMUM WHERE THE REACH DEPTH EXCEEDS 20 INCHES. HIGH FORWARD REACH SHALL NOT EXCEED 25 INCHES IN DEPTH. §11B-308.2.2, FIGURE 11B-308.2.2 23.HIGH SIDE REACH SHALL BE 48 INCHES MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 INCHES MINIMUM ABOVE THE FINISH FLOOR WHERE THE SIDE REACH IS UNOBSTRUCTED OR THE DEPTH OF ANY OBSTRUCTION DOES NOT EXCEED 10 INCHES. §11B-308.3.1, FIGURE 11B-308.3.1 24.HIGH SIDE REACH SHALL BE 46 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND WHERE THE HIGH SIDE REACH IS OVER AN OBSTRUCTION MORE THAN 10 INCHES BUT NOT MORE THAN 24 INCHES IN DEPTH. §11B-308.3.2, FIGURE 11B- 308.3.2 25.OBSTRUCTIONS FOR HIGH SIDE REACH SHALL NOT EXCEED 34 INCHES IN HEIGHT AND 24 INCHES IN DEPTH. §11B-308.3.2, FIGURE 11B-308.3.2 26.OBSTRUCTIONS FOR HIGH SIDE REACH SHALL NOT EXCEED 34 INCHES IN HEIGHT AND 24 INCHES IN DEPTH. §11B-308.3.2, FIGURE 11B-308.3.2 27.OBSTRUCTED HIGH SIDE REACH FOR THE TOP OF WASHING MACHINES AND CLOTHES DRYERS SHALL BE PERMITTED TO BE 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR. §11B-308.3.2 28.OBSTRUCTED HIGH SIDE REACH FOR THE OPERABLE PARTS OF FUEL DISPENSERS SHALL BE PERMITTED TO BE 54 INCHES MAXIMUM MEASURED FROM THE SURFACE OF THE VEHICULAR WAY WHERE FUEL DISPENSERS ARE INSTALLED ON EXISTING CURBS. §11B-308.3.2 OPERABLE PARTS 1.OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM. §11B-309.4 C.ACCESSIBLE ROUTES DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE 1.DETECTABLE WARNING SURFACES SHALL BE YELLOW AND APPROXIMATE FS 33538 OF FEDERAL STANDARD 595C. §11B- 705.1.1.3.1 2.DETECTABLE WARNING SURFACES SHALL PROVIDE A 70 PERCENT MINIMUM VISUAL CONTRAST WITH ADJACENT WALKING SURFACES. CONTRAST IN PERCENT SHALL BE DETERMINED BY: CONTRAST PERCENT = [(B1-B2)/B1] X 100 WHERE B1 = LIGHT REFLECTANCE VALUE (LRV) OF THE LIGHTER AREA AND B2 = LIGHT REFLECTANCE VALUE (LRV) OF THE DARKER AREA §11B-705.1.1.3.2 (SEE EXCEPTION) DOORS DOORWAYS, AND GATES 3.DOORS, DOORWAYS, AND GATES PROVIDING USER PASSAGE SHALL BE PROVIDED IN ACCORDANCE WITH 11B-206.5 DOORS, DOORWAYS, AND GATES. §11B-206.5 4.DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH 11B-404 DOORS, DOORWAYS, AND GATES. §11B-404.1 5.DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES. §11B-404.2.3 6.SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.1. §11B- 404.2.4.1 7.DOORWAYS LESS THAN 36 INCHES WIDE WITHOUT DOORS OR GATES, SLIDING DOORS, OR FOLDING DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.2. §11B-404.2.4.2 8.MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES OF THE LATCH SIDE AN INTERIOR DOORWAY, OR WITHIN 24 INCHES OF THE LATCH SIDE OF AN EXTERIOR DOORWAY, PROJECTS MORE THAN 8 INCHES BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE. §11B- 404.2.4.3 9.THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE ½ INCH HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES AND 11B-303 CHANGES IN LEVEL. §11B- 404.2.5 10.HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH 11B-309.4 OPERATION. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. §11B-404.2.7 11.THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: §11B-404.2.9 a. INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAXIMUM. b. SLIDING OR FOLDING DOORS: 5 POUNDS MAXIMUM. c. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. d. EXTERIOR HINGED DOORS: 5 POUNDS MAXIMUM. 12.SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. §11B-404.2.10 RAMPS 13.RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%). §11B-405.2 14.CROSS SLOPE OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48 (2.083%). §11B-405.3 15.FLOOR OR GROUND SURFACES OF RAMP RUNS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES. CHANGES IN LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE NOT PERMITTED ON RAMP RUNS. §11B-405.4 16.THE CLEAR WIDTH OF A RAMP RUN SHALL BE 48 INCHES MINIMUM. §11B-405.5 17.THE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES MAXIMUM. §11B-405.6 18.RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE BOTTOM OF EACH RAMP RUN. §11B-405.7 19.LANDINGS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES. CHANGES IN LEVEL ARE NOT PERMITTED. §11B- 405.7.1 20.THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. §11B- 405.7.2 21.TOP LANDINGS SHALL BE 60 INCHES WIDE MINIMUM. §11B-405.7.2.1 22.THE LANDING CLEAR LENGTH SHALL BE 60 INCHES LONG MINIMUM. §11B-405.7.3 23.BOTTOM LANDINGS SHALL EXTEND 72 INCHES MINIMUM IN THE DIRECTION OF RAMP RUN. §11B-405.7.3.1 24.RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING 60 INCHES MINIMUM BY 72 INCHES MINIMUM IN THE DIRECTION OF DOWNWARD TRAVEL FROM THE UPPER RAMP RUN. §11B-405.7.4 25.WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY 11B-404.2.4 AND 11B-404.3.2 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. DOORS, WHEN FULLY OPEN, SHALL NOT REDUCE THE REQUIRED RAMP LANDING WIDTH BY MORE THAN 3 INCHES. DOORS, IN ANY POSITION, SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP LANDING TO LESS THAN 42 INCHES. §11B-405.7.5 26.RAMP RUNS SHALL HAVE COMPLIANT HANDRAILS PER 11B-505 HANDRAILS. §11B-405.8 27.EDGE PROTECTION COMPLYING WITH 11B-405.9.2 CURB OR BARRIER SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. §11B-405.9 (SEE EXCEPTIONS) 28.A CURB, 2 INCHES HIGH MINIMUM, OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4 INCH DIAMETER SPHERE, WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR OR GROUND SURFACE. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE A CONTINUOUS AND UNINTERRUPTED BARRIER ALONG THE LENGTH OF THE RAMP. §11B-405.9.2 29.LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. §11B-405.10 HANDRAILS HANDRAILS 1.HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS. §11B-505.2 2.HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS AND RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS. §11B-505.3 3.TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES MINIMUM AND 38 INCHES MAXIMUM VERTICALLY ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. HANDRAILS SHALL BE AT A CONSISTENT HEIGHT ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. §11B-505.4 4.CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACES AND ADJACENT SURFACES SHALL BE 1½ INCHES MINIMUM. HANDRAILS MAY BE LOCATED IN A RECESS IF THE RECESS IS 3 INCHES MAXIMUM DEEP AND 18 INCHES MINIMUM CLEAR ABOVE THE TOP OF THE HANDRAIL. §11B-505.5 5.HANDRAIL GRIPPING SURFACES SHALL BE CONTINUOUS ALONG THEIR LENGTH AND SHALL NOT BE OBSTRUCTED ALONG THEIR TOPS OR SIDES. THE BOTTOMS OF HANDRAIL GRIPPING SURFACES SHALL NOT BE OBSTRUCTED FOR MORE THAN 20 PERCENT OF THEIR LENGTH. WHERE PROVIDED, HORIZONTAL PROJECTIONS SHALL OCCUR 1½ INCHES MINIMUM BELOW THE BOTTOM OF THE HANDRAIL-GRIPPING SURFACE. §11B-505.6 6.HANDRAIL GRIPPING SURFACES WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1¼ INCHES MINIMUM AND 2 INCHES MAXIMUM. §11B-505.7.1 7.HANDRAIL GRIPPING SURFACES WITH A NON-CIRCULAR CROSS SECTION SHALL HAVE A PERIMETER DIMENSION OF 4 INCHES MINIMUM AND 6¼ INCHES MAXIMUM, AND A CROSS-SECTION DIMENSION OF 2¼ INCHES MAXIMUM. §11B-505.7.2 8.HANDRAIL GRIPPING SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION OF STAIR FLIGHTS AND RAMP RUNS IN ACCORDANCE WITH SECTION 11B-505.10 HANDRAIL EXTENSIONS. §11B-505.10 9.RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES MINIMUM BEYOND THE TOP AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN. §11B-505.10.1 10.AT THE TOP OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES MINIMUM BEGINNING DIRECTLY ABOVE THE FIRST RISER NOSING. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. §11B-505.10.2 11.AT THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. THE HORIZONTAL EXTENSION OF A HANDRAIL SHALL BE 12 INCHES LONG MINIMUM AND A HEIGHT EQUAL TO THAT OF THE SLOPING PORTION OF THE HANDRAIL AS MEASURED ABOVE THE STAIR NOSINGS. EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. §11B-505.10. STAIRWAYS 1.A STAIR IS DEFINED AS A CHANGE IN ELEVATION, CONSISTING OF ONE OR MORE RISERS. §11B-202 2.ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTHS. RISERS SHALL BE 4 INCHES HIGH MINIMUM AND 7 INCHES HIGH MAXIMUM. TREADS SHALL BE 11 INCHES DEEP MINIMUM. CURVED STAIRWAYS WITH WINDER TREADS ARE PERMITTED AT STAIRS WHICH ARE NOT PART OF A REQUIRED MEANS OF EGRESS. (SEE EXCEPTION) §11B-504.2 3.OPEN RISERS ARE NOT PERMITTED. §11B-504.3 (SEE EXCEPTIONS) 4.INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. THE STRIPE SHALL BE A MINIMUM OF 2 INCHES WIDE TO A MAXIMUM OF 4 INCHES WIDE PLACED PARALLEL TO, AND NOT MORE THAN 1 INCH FROM, THE NOSE OF THE STEP OR UPPER APPROACH. THE STRIPE SHALL EXTEND THE FULL WIDTH OF THE STEP OR UPPER APPROACH AND SHALL BE OF MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE. GROOVES SHALL NOT BE USED TO SATISFY THIS REQUIREMENT. §11B-504.4.1 5.THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE ½ INCH MAXIMUM. NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED. RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAXIMUM FROM VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL EXTEND 1¼ INCHES MAXIMUM OVER THE TREAD BELOW. §11B-504.5 (SEE EXCEPTION FOR EXISTING BUILDINGS) 6.STAIRS SHALL HAVE HANDRAILS COMPLYING WITH SECTION 11B-505 HANDRAILS. §11B-504.6 7.STAIR TREADS AND LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. §11B-504.7 8.FLOOR IDENTIFICATION SIGNS REQUIRED BY CHAPTER 10, SECTION 1022.9 COMPLYING WITH SECTIONS 11B-703.1 SIGNS GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS SHALL BE LOCATED AT THE LANDING OF EACH FLOOR LEVEL, PLACED ADJACENT TO THE DOOR ON THE LATCH SIDE, IN ALL ENCLOSED STAIRWAYS IN BUILDINGS TWO OR MORE STORIES IN HEIGHT TO IDENTIFY THE FLOOR LEVEL. AT THE EXIT DISCHARGE LEVEL, THE SIGN SHALL INCLUDE A RAISED FIVE POINTED STAR LOCATED TO THE LEFT OF THE IDENTIFYING FLOOR LEVEL. THE OUTSIDE DIAMETER OF THE STAR SHALL BE THE SAME AS THE HEIGHT OF THE RAISED CHARACTERS. §11B-504.8 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS 9. PERPENDICULAR RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%). §11B-406.2.1 10. FOR PERPENDICULAR RAMPS, WHERE PROVIDED, CURB RAMP FLARES SHALL NOT BE STEEPER THAN 1:10. §11B-406.2, FIGURE 11B-406.2.2 11. THE RUNNING SLOPE OF THE CURB RAMP SEGMENTS SHALL BE IN-LINE WITH THE DIRECTION OF SIDEWALK TRAVEL. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%). §11B-406.3.1, FIGURE 11B-406.3.2 12. A TURNING SPACE 48 INCHES MINIMUM BY 48 INCHES MINIMUM SHALL BE PROVIDED AT THE BOTTOM OF THE CURB RAMP. THE SLOPE OF THE TURNING SPACE IN ALL DIRECTIONS SHALL BE 1:48 MAXIMUM (2.083%). §11B-406.3.2 13. BLENDED TRANSITION RAMPS HALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:20 (5%). §11B-406.4.1 14. CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES. §11B-406.5.1 15. THE CLEAR WIDTH OF CURB RAMP RUNS (EXCLUDING ANY FLARED SIDES), BLENDED TRANSITIONS, AND TURNING SPACES SHALL BE 48 INCHES MINIMUM. §11B-406.5.2 16. LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB RAMPS AND BLENDED TRANSITIONS (PARALLEL CURB RAMPS SHALL NOT BE REQUIRED TO COMPLY). THE LANDING CLEAR LENGTH SHALL BE 48 INCHES MINIMUM. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING ANY FLARED SIDES, OR THE BLENDED TRANSITION LEADING TO THE LANDING. THE SLOPE OF THE LANDING IN ALL DIRECTIONS SHALL BE 1:48 (2.083%) MAXIMUM. §11B-406.5.3 17. GRADE BREAKS AT THE TOP AND BOTTOM OF CURB RAMP RUNS SHALL BE PERPENDICULAR TO THE DIRECTION OF THE RAMP RUN. GRADE BREAKS SHALL NOT BE PERMITTED ON THE SURFACE OF RAMP RUNS AND TURNING SPACES. SURFACE SLOPES THAT MEET AT GRADE BREAKS SHALL BE FLUSH. §11B-406.5.6 18. THE CROSS SLOPE OF CURB RAMPS AND BLENDED TRANSITIONS SHALL BE 1:48 (2.083%) MAXIMUM. §11B-406.5.7 19. COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO AND WITHIN 24 INCHES OF THE CURB RAMP SHALL NOT BE STEEPER THAN 1:20 (5%). THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS, AND STREETS SHALL BE AT THE SAME LEVEL. §11B-406.5.8 20. THE BOTTOM OF DIAGONAL CURB RAMPS SHALL HAVE A CLEAR SPACE 48 INCHES MINIMUM OUTSIDE ACTIVE TRAFFIC LANES OF THE ROADWAY. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS SHALL PROVIDE THE 48 INCHES MINIMUM CLEAR SPACE WITHIN THE MARKINGS. §11B-406.5.9 21. CURB RAMPS AND BLENDED TRANSITIONS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH 11B-705 DETECTABLE WARNINGS. §11B-406.5.12 22. RAISED ISLANDS IN CROSSINGS SHALL BE CUT THROUGH LEVEL WITH THE STREET OR HAVE CURB RAMPS AT BOTH SIDES. THE CLEAR WIDTH OF THE ACCESSIBLE ROUTE AT ISLANDS SHALL BE 60 INCHES WIDE MINIMUM. WHERE CURB RAMPS ARE PROVIDED, THEY SHALL COMPLY WITH 11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS. LANDINGS COMPLYING WITH 11B-406.5.3 LANDINGS AND THE ACCESSIBLE ROUTE SHALL BE PERMITTED TO OVERLAP. ISLANDS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH 11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE. §11B-406.6, FIGURE 11B-406.6 D.GENERAL SITE AND BUILDING ELEMENTS 1.WHERE PARKING SPACES ARE PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN NUMBER AND KIND REQUIRED PER SECTION 11B-208 PARKING SPACES. §11B-208.1 2.WHERE PASSENGER LOADING ZONES, DROP-OFF ZONES, AND/OR BUS STOPS ARE PROVIDED, ACCESSIBLE PASSENGER LOADING ZONES, DROP-OFF ZONES, AND/OR BUS STOPS ARE REQUIRED. 3.WHERE ELECTRIC VEHICLE CHARGING STATIONS (EVCS) ARE PROVIDED, THEY SHALL COMPLY WITH SECTION 11B-812 AS REQUIRED BY SECTION 11B-228.3. 4.EVCS COMPLYING WITH SECTION 11B-812 THAT SERVE A PARTICULAR BUILDING OR FACILITY SHALL BE LOCATED ON AN ACCESSIBLE ROUTE TO AN ENTRANCE COMPLYING WITH SECTION 11B-206.4. WHERE EVCS DO NOT SERVE A PARTICULAR BUILDING OR FACILITY, EVCS COMPLYING WITH SECTION 11B-812 SHALL BE LOCATED ON AN ACCESSIBLE ROUTE TO AN ACCESSIBLE PEDESTRIAN ENTRANCE OF THE EV CHARGING FACILITY. E.PLUMBING FIXTURES AND FACILITIES DRINKING FOUNTAINS 1.DRINKING FOUNTAINS SHALL COMPLY WITH SECTIONS 11B-307 PROTRUDING OBJECTS AND 11B-602 GENERAL REQUIREMENTS. §11B-602.1 2.UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 CLEAR FLOOR OR GROUND SPACE POSITIONED FOR A FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 KNEE AND TOE CLEARANCE SHALL BE PROVIDED. §11B-602.2 3.SPOUT OUTLETS SHALL BE 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-602.4 4.THE SPOUT SHALL BE LOCATED 15 INCHES MINIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES MAXIMUM FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. §11B-602.5 5.THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES HIGH MINIMUM AND SHALL BE LOCATED 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATED LESS THAN 3 INCHES FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 30 DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED BETWEEN 3 INCHES AND 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAXIMUM. §11B-602.6 6.SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-602.7 7.WALL AND POST-MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18 INCHES MINIMUM AND 19 INCHES MAXIMUM IN DEPTH. §11B-602.8 8.ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN SUCH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32 INCHES WIDE MINIMUM AND 18 INCHES DEEP MINIMUM, AND SHALL COMPLY WITH SECTION 11B-305.7 MANEUVERING CLEARANCE. WHEN USED, WING WALLS OR BARRIERS SHALL PROTECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES VERTICALLY FROM THE FLOOR OR GROUND SURFACE. §11B-602.9 TOILET AND BATHING ROOM CLEARANCES 9.DOORS TO UNISEX TOILET ROOMS AND UNISEX BATHING ROOMS SHALL HAVE PRIVACY LATCHES. §11B-213.2.1 10.MIRRORS LOCATED ABOVE THE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITHIN THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE THE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-603.3 11.COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308. SHELVES SHALL BE LOCATED 40 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR. MEDICINE CABINETS SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44 INCHES MAXIMUM ABOVE THE FINISH FLOOR. §11B-603.4 12.WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR. BABY CHANGING STATIONS ARE NOT REQUIRED TO COMPLY WITH SECTION 11B-603.5 (SEE EXCEPTION) §11B-603.5 WATER CLOSETS AND TOILET COMPARTMENTS 13.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 11B-309.4 OPERATION EXCEPT THEY SHALL BE LOCATED 44 INCHES MAXIMUM ABOVE THE FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET EXCEPT IN AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH SECTION 11B-604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS. §11B-604.6 14.TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 11B-309.4 OPERATION AND SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW THE GRAB BAR, 19 INCHES MINIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW. §11B-604.7 15.SANITARY NAPKIN DISPOSAL UNITS, IF PROVIDED, SHALL COMPLY WITH SECTION 11B-309.4 AND SHALL BE WALL MOUNTED AND LOCATED ON THE SIDEWALL BETWEEN THE REAR WALL OF THE TOILET AND THE TOILET PAPER DISPENSER, ADJACENT TO THE TOILET PAPER DISPENSER. THE DISPOSAL UNIT SHALL BE LOCATED BELOW THE GRAB BAR WITH THE OPENING OF THE DISPOSAL UNIT 19 INCHES MINIMUM (483 MM) ABOVE THE FINISH FLOOR. §11B-604.7.2 16.URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13½ INCHES DEEP MINIMUM MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE. §11B-605.2 17.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 11B-309 OPERABLE PARTS EXCEPT THAT THE FLUSH CONTROL SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 44 INCHES ABOVE THE FINISH FLOOR. §11B-605.4 18.FOR LAVATORIES AND SINKS, A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11B-305 CLEAR FLOOR OR GROUND SURFACES, POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 KNEE AND TOE CLEARANCE SHALL BE PROVIDED. §11B-606.2 19.LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-606.3 SIGNS RELATED TO TOILETS AND BATHING FACILITIES 20.ENTRANCES LEADING TO TOILET ROOMS AND BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING ROOM GEOMETRIC SYMBOLS. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST COMPLIANT TOILET ROOM OR BATHING ROOM WITHIN THE FACILITY SHALL BE PROVIDED. SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, THE TOILET ROOMS OR BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. WHERE CLUSTERED SINGLE USER TOILET ROOMS OR BATHING FACILITIES ARE PERMITTED TO USE EXCEPTIONS TO 11B-213.2 TOILET AND BATHING ROOMS, TOILET ROOMS OR BATHING FACILITIES COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA UNLESS ALL TOILET ROOMS AND BATHING FACILITIES COMPLY WITH 11B-603 TOILET AND BATHING ROOMS. EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC TOILET ROOMS OR BATHING ROOMS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE ROOMS POSTED IN OR NEAR THE BUILDING LOBBY OR ENTRANCE ON A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.8 21. PICTOGRAMS SHALL COMPLY WITH THE FOLLOWING: a. PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. §11B-703.6.1 b. PICTOGRAMS AND THEIR FIELD SHALL HAVE A NON-GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH THEIR FIELD WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. §11B-703.6.2 c. PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. TEXT DESCRIPTORS SHALL COMPLY WITH 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.4 INSTALLATION HEIGHT AND LOCATION. §11B-703.6.3 d. THE INSTALLATION HEIGHT AND LOCATION OF PICTOGRAM SIGNS SHALL BE PER §11B-703.4.1. 22. SYMBOLS SHALL COMPLY WITH THE FOLLOWING: a. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS. THE SYMBOL SHALL BE MOUNTED AT 58 INCHES MINIMUM AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED FROM THE CENTERLINE OF THE SYMBOL. WHERE A DOOR IS PROVIDED, THE SYMBOL SHALL BE MOUNTED WITHIN 1 INCH OF THE VERTICAL CENTERLINE OF THE DOOR. §11B-703.7.2.6 (SEE EXCEPTION) b. A TRIANGLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO MEN'S TOILET AND BATHING FACILITIES AND IT SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE, ¼ INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.1 c. A CIRCLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO WOMEN'S TOILET AND BATHING FACILITIES AND IT SHALL BE IDENTIFIED BY A CIRCLE, ¼ INCH THICK AND 12 INCHES IN DIAMETER. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.2 d. COMBINED CIRCLE AND TRIANGLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO UNISEX TOILET AND BATHING FACILITIES AND IT SHALL BE SHALL BE IDENTIFIED BY A CIRCLE, ¼ INCH THICK AND 12 INCHES IN DIAMETER WITH A ¼ INCH THICK TRIANGLE WITH A VERTEX POINTING UPWARD SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12-INCH DIAMETER. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.3 WASHING MACHINE AND CLOTHES DRYERS 1.WASHING MACHINES AND CLOTHES DRYER'S OPERABLE PARTS MUST COMPLY WITH SECTION 11B-309 OPERABLE PARTS. §11B-611.3 2.TOP LOADING MACHINES SHALL HAVE THE DOOR TO THE LAUNDRY COMPARTMENT LOCATED 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR. FRONT LOADING MACHINES SHALL HAVE THE BOTTOM OF THE OPENING TO THE LAUNDRY COMPARTMENT LOCATED 15 INCHES MINIM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR. §11B-611.4 F.COMMUNICATION ELEMENTS AND FEATURES FIRE ALARM SYSTEMS 1.WHERE FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS PROVIDE AUDIBLE ALARM COVERAGE, ALARMS SHALL COMPLY WITH 11B-215 FIRE ALARM SYSTEMS. §11B-215.1 (SEE EXCEPTION) 2.ALARMS IN PUBLIC USE AREAS AND COMMON USE AREAS SHALL COMPLY WITH 702 CHAPTER 9, SECTION 907.5.2.3.1. §11B-215.2 3.WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE WIRING SYSTEM SHALL BE DESIGNED SO THAT VISIBLE ALARMS COMPLYING WITH 702 CHAPTER 9, SECTION 907.5.2.3.2 CAN BE INTEGRATED INTO THE ALARM SYSTEM. §11B-215.3 4.FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72 (1999 OR 2002 EDITION) (INCORPORATED BY REFERENCE, SEE “REFERENCED STANDARDS” IN CHAPTER 1), EXCEPT THAT THE MAXIMUM ALLOWABLE SOUND LEVEL OF AUDIBLE NOTIFICATION APPLIANCES COMPLYING WITH SECTION 4-3.2.1 OF NFPA 72 (1999 EDITION) SHALL HAVE A SOUND LEVEL NO MORE THAN 110 DB AT THE MINIMUM HEARING DISTANCE FROM THE AUDIBLE APPLIANCE. IN ADDITION, ALARMS IN GUEST ROOMS REQUIRED TO PROVIDE COMMUNICATION FEATURES SHALL COMPLY WITH SECTIONS 4-3 AND 4-4 OF NFPA 72 (1999 EDITION) OR SECTIONS 7.4 AND 7.5 OF NFPA 72 (2002 EDITION), AND CHAPTER 9, SECTIONS 907.5.2.1 AND 907.5.2.3. §11B-702.1 ASSISTIVE LISTENING SYSTEMS 5.ASSISTIVE LISTENING SYSTEMS SHALL BE PROVIDED IN ASSEMBLY AREAS, INCLUDING CONFERENCE AND MEETING ROOMS, USED FOR THE PURPOSE OF ENTERTAINMENT, EDUCATIONAL OR CIVIC GATHERINGS, OR SIMILAR PURPOSES. §202, §11B- 219.2 NOTE: ASSEMBLY AREAS INCLUDE, BUT ARE NOT LIMITED TO, CLASSROOMS, LECTURE HALLS, COURTROOMS, PUBLIC MEETING ROOMS, PUBLIC HEARING ROOMS, LEGISLATIVE CHAMBERS, MOTION PICTURE HOUSES, AUDITORIA, THEATERS, PLAYHOUSES, DINNER THEATERS, CONCERT HALLS, CENTERS FOR THE PERFORMING ARTS, AMPHITHEATERS, ARENAS, STADIUMS, GRANDSTANDS, OR CONVENTION CENTERS. §202, §11B-219.2 6.ASSISTIVE LISTENING SYSTEM SHALL PROVIDE AN AMPLIFICATION SYSTEM UTILIZING TRANSMITTERS, RECEIVERS, AND COUPLING DEVICES TO BYPASS THE ACOUSTICAL SPACE BETWEEN A SOUND SOURCE AND A LISTENER BY MEANS OF INDUCTION LOOP, RADIO FREQUENCY, INFRARED, OR DIRECT-WIRED EQUIPMENT. §202 7.WHERE A BUILDING CONTAINS MORE THAN ONE ASSEMBLY AREA UNDER ONE MANAGEMENT, THE TOTAL NUMBER OF REQUIRED RECEIVERS MAY BE CALCULATED USING THE TOTAL NUMBER OF SEATS IN THE ASSEMBLY AREAS PROVIDED THAT ALL RECEIVERS ARE USABLE WITH ALL SYSTEMS. §11B-219.3 (SEE EXCEPTION) 8.TWENTY-FIVE PERCENT MINIMUM OF RECEIVERS PROVIDED FOR ASSISTIVE LISTENING SYSTEMS, BUT NO FEWER THAN TWO, SHALL BE HEARING-AID COMPATIBLE EXCEPT WHEN ALL SEATS IN AN ASSEMBLY AREA ARE SERVED BY MEANS OF AN INDUCTION LOOP. §11B-219.3 9.WHEN ASSISTIVE-LISTENING SYSTEMS ARE LIMITED TO SPECIFIC AREAS OR SEATS, SUCH AREAS OR SEATS SHALL BE WITHIN A 50-FOOT VIEWING DISTANCE OF THE STAGE OR PLAYING AREA AND SHALL HAVE A COMPLETE VIEW OF THE STAGE OR PLAYING AREA. §11B-219.4 10.PERMANENTLY INSTALLED ASSISTIVE-LISTENING SYSTEMS ARE REQUIRED IN AREAS IF (1) THEY HAVE FIXED SEATING AND (2A) THEY ACCOMMODATE AT LEAST 50 PERSONS OR (2B) THEY HAVE AUDIO-AMPLIFICATION SYSTEMS, EXCEPT THOSE USED EXCLUSIVELY FOR PAGING AND/OR BACKGROUND MUSIC. §11B-219.2, §11B-219.5 11.PORTABLE ASSISTIVE-LISTENING SYSTEMS MAY SERVE MORE THAN ONE CONFERENCE OR MEETING ROOMS IF AN ADEQUATE NUMBER OF ELECTRICAL OUTLETS OR OTHER SUPPLEMENTARY WIRING IS PROVIDED AND PERMANENTLY INSTALLED SYSTEMS ARE NOT REQUIRED. §11B-219.5 12.RECEIVERS REQUIRED FOR USE WITH AN ASSISTIVE LISTENING SYSTEM SHALL INCLUDE A 1/8 INCH STANDARD MONO JACK. §11B-706.2 13.RECEIVERS REQUIRED TO BE HEARING AID COMPATIBLE SHALL INTERFACE WITH TELECOILS IN HEARING AIDS THROUGH THE PROVISION OF NECK LOOPS. §11B-706.3 14.ASSISTIVE LISTENING SYSTEMS SHALL BE CAPABLE OF PROVIDING A SOUND PRESSURE LEVEL FROM 110 - 118 DB WITH A DYNAMIC RANGE ON THE VOLUME CONTROL OF 50 DB. §11B-706.4 15.SIGNAL-TO-NOISE RATIO FOR INTERNALLY GENERATED NOISE IN ASSISTIVE LISTENING SYSTEMS SHALL BE 18 DB MINIMUM. §11B-706.5 16.PEAK CLIPPING SHALL NOT EXCEED 18 DB OF CLIPPING RELATIVE TO THE PEAKS OF SPEECH. §11B-706.6 TWO-WAY COMMUNICATION SYSTEMS 17.TWO-WAY COMMUNICATION SYSTEMS THAT ARE PROVIDED TO GAIN ADMITTANCE TO A BUILDING OR FACILITY OR TO RESTRICTED AREAS WITHIN A BUILDING OR FACILITY SHALL PROVIDE BOTH AUDIBLE AND VISUAL SIGNALS. HANDSET CORDS, IF PROVIDED, SHALL BE 29 INCHES LONG MINIMUM. §11B-230.1, §11B-708 18.COMMON USE OR PUBLIC USE SYSTEM INTERFACE OF COMMUNICATIONS SYSTEMS BETWEEN A RESIDENTIAL DWELLING UNIT AND A SITE, BUILDING, OR FLOOR ENTRANCE SHALL INCLUDE THE CAPABILITY OF SUPPORTING VOICE AND TTY COMMUNICATION WITH THE RESIDENTIAL DWELLING UNIT INTERFACE. §11B-708.4.1 19.RESIDENTIAL DWELLING UNIT SYSTEM INTERFACE OF COMMUNICATIONS SYSTEMS BETWEEN A RESIDENTIAL DWELLING UNIT AND A SITE, BUILDING, OR FLOOR ENTRANCE SHALL INCLUDE A TELEPHONE JACK CAPABLE OF SUPPORTING VOICE AND TTY COMMUNICATION WITH THE COMMON USE OR PUBLIC USE SYSTEM INTERFACE. §11B-708.4.2 TELEPHONES 20.WHERE COIN-OPERATED PUBLIC PAY TELEPHONES, COIN LESS PUBLIC PAY TELEPHONES, PUBLIC CLOSED-CIRCUIT TELEPHONES, PUBLIC COURTESY PHONES, OR OTHER TYPES OF PUBLIC TELEPHONES ARE PROVIDED, PUBLIC TELEPHONES SHALL BE PROVIDED IN ACCORDANCE WITH 11B-217 TELEPHONES FOR EACH TYPE OF PUBLIC TELEPHONE PROVIDED. FOR PURPOSES OF THIS SECTION, A BANK OF TELEPHONES SHALL BE CONSIDERED TO BE TWO OR MORE ADJACENT TELEPHONES. §11B-217.1 21.EXCEPT DRIVE-UP ONLY PUBLIC TELEPHONES, WHERE PUBLIC TELEPHONES ARE PROVIDED, WHEELCHAIR ACCESSIBLE TELEPHONES COMPLYING WITH 11B-704.2 SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 11B-217.2. §11B-217.2 22.ALL PUBLIC TELEPHONES SHALL HAVE VOLUME CONTROLS COMPLYING WITH 11B-704.3. §11B-217.3 23.TTYS COMPLYING WITH 11B-704.4 SHALL BE PROVIDED IN ACCORDANCE WITH 11B-217.4. 24.WHERE A BANK OF TELEPHONES IN THE INTERIOR OF A BUILDING CONSISTS OF THREE OR MORE PUBLIC PAY TELEPHONES, AT LEAST ONE PUBLIC PAY TELEPHONE AT THE BANK SHALL BE PROVIDED WITH A SHELF AND AN ELECTRICAL OUTLET IN ACCORDANCE WITH 11B-704.5. §11B-217.5 (SEE EXCEPTION) SIGNS 1.EXCEPT BUILDING DIRECTORIES, MENUS, SEAT AND ROW DESIGNATIONS IN ASSEMBLY AREAS, OCCUPANT NAMES, BUILDING ADDRESSES, AND COMPANY NAMES AND LOGOS, NEW OR ALTERED SIGNS SHALL BE PROVIDED IN ACCORDANCE WITH 11B-216 SIGNS AND SHALL COMPLY WITH 11B-703 SIGNS. THE ADDITION OF OR REPLACEMENT OF SIGNS SHALL NOT TRIGGER ANY ADDITIONAL PATH OF TRAVEL REQUIREMENTS. §11B-216.1 2.INTERIOR AND EXTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACESSHALL COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS. WHERE PICTOGRAMS ARE PROVIDED AS DESIGNATIONS OF PERMANENT INTERIOR ROOMS AND SPACES, THE PICTOGRAMS SHALL COMPLY WITH 11B-703.6 PICTOGRAMS AND SHALL HAVE TEXT DESCRIPTORS COMPLYING WITH 11B-703.2 AND 11B-703.5. §11B-216.2 (SEE EXCEPTION) 3.SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR AND EXTERIOR SPACES AND FACILITIES OF THE SITE SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS. §11B-216.3 4.SIGNS FOR MEANS OF EGRESS SHALL COMPLY WITH 11B-216.4 MEANS OF EGRESS: a. SIGNS REQUIRED BY SECTION 1013.4 AT DOORS TO EXIT PASSAGEWAYS, EXIT DISCHARGE, AND EXIT STAIRWAYS SHALL BE IDENTIFIED BY TACTILE SIGNS COMPLYING COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS. §11B-216.4.1 b. SIGNS REQUIRED BY SECTION 1009.11 TO PROVIDE INSTRUCTIONS IN AREAS OF REFUGE SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS. SIGNS REQUIRED BY SECTION 1009.9 AT DOORS TO AREAS OF REFUGE AND EXTERIOR AREAS FOR ASSISTED RESCUE SHALL COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS AND INCLUDE AN INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. §11B- 216.4.2 c. SIGNS REQUIRED BY SECTION 1009.10 TO PROVIDE DIRECTIONS TO ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS. §11B-216.4.3 d. SIGNS REQUIRED BY SECTION 1010.1.9.7, ITEM 6.4 AT DOORS WITH DELAYED EGRESS LOCKS SHALL COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS. §11B-216.4.4 5.SIGNS WITHIN PARKING FACILITIES SHALL COMPLY WITH SECTION 11B-216.5.2. §11B-216.5 6.IN EXISTING BUILDINGS AND FACILITIES WHERE NOT ALL ENTRANCES COMPLYWITH 11B-404 DOORS, DOORWAYS, AND GATES, COMPLIANT ENTRANCES SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. DIRECTIONAL SIGNS COMPLYING WITH 11B-703.5 VISUAL CHARACTERS THAT INDICATE THE LOCATION OF THE NEAREST ENTRANCE COMPLYING WITH 11B-404 SHALL BE PROVIDED AT ENTRANCES THAT DO NOT COMPLY WITH 11B-404 DOORS, DOORWAYS, AND GATES. DIRECTIONAL SIGNS COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE ISA COMPLYING WITH 11B-703.7.2.1 ISA, INDICATING THE ACCESSIBLE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE SHALL BE PROVIDED AT JUNCTIONS WHEN THE ACCESSIBLE ROUTE DIVERGES FROM THE REGULAR CIRCULATION PATH. §11B-216.6 7.WHERE EXISTING ELEVATORS DO NOT COMPLY WITH 11B-407 ELEVATORS, COMPLIANT ELEVATORS SHALL BE CLEARLY IDENTIFIED WITH THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC ELEVATORS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE ELEVATORS POSTED IN THE BUILDING LOBBY ON A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE ISA COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.7 8.ENTRANCES TO TOILET ROOMS AND BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING ROOM GEOMETRIC SYMBOLS. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST COMPLIANT TOILET ROOM OR BATHING ROOM WITHIN THE FACILITY SHALL BE PROVIDED. SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.8 9.WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, THE TOILET ROOMS OR BATHING ROOMS COMPLYING WITH SECTION 11B-603, SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1 ISA. 11B-216.8 10.WHERE CLUSTERED SINGLE USER TOILET ROOMS OR BATHING FACILITIES ARE PERMITTED TO USE EXCEPTIONS TO 11B-213.2 TOILET AND BATHING ROOMS, TOILET ROOMS OR BATHING FACILITIES COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA UNLESS ALL TOILET ROOMS AND BATHING FACILITIES COMPLY WITH 11B-603 TOILET AND BATHING ROOMS. §11B-216.8 11.EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC TOILET ROOMS OR BATHING ROOMS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE ROOMS POSTED IN OR NEAR THE BUILDING LOBBY OR ENTRANCE ON A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.8 12.IDENTIFICATION AND DIRECTIONAL SIGNS FOR PUBLIC TTYS SHALL BE PROVIDED IN ACCORDANCE WITH 11B-216.9 TTYS. §11B- 216.9 a. PUBLIC TTYS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF TTY COMPLYING WITH 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY. §11B-216.9.1 b. DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST PUBLIC TTY SHALL BE PROVIDED AT ALL BANKS OF PUBLIC PAY TELEPHONES NOT CONTAINING A PUBLIC TTY. IN ADDITION, WHERE SIGNS PROVIDE DIRECTION TO PUBLIC PAY TELEPHONES, THEY SHALL ALSO PROVIDE DIRECTION TO PUBLIC TTYS. IF A FACILITY HAS NO BANKS OF TELEPHONES, THE DIRECTIONAL SIGNS SHALL BE PROVIDED AT THE ENTRANCE OR IN A BUILDING DIRECTORY. DIRECTIONAL SIGNS SHALL COMPLY WITH 11B-703.5 AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF TTY COMPLYING WITH 11B-703.7.2.2. §11B-216.9.2 13.EACH ASSEMBLY AREA REQUIRED BY 11B-219 ASSISTIVE LISTENING SYSTEMS TO PROVIDE ASSISTIVE LISTENING SYSTEMS SHALL PROVIDE SIGNS INFORMING PATRONS OF THE AVAILABILITY OF THE ASSISTIVE LISTENING SYSTEM. THE SIGN SHALL INCLUDE WORDING THAT STATES “ASSISTIVE-LISTENING SYSTEM AVAILABLE” AND SHALL BE POSTED IN A PROMINENT PLACE AT OR NEAR THE ASSEMBLY AREA ENTRANCE. ASSISTIVE LISTENING SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS COMPLYING WITH 11B-703.7.2.4 ASSISTIVE LISTENING SYSTEMS. §11B-216.10 (SEE EXCEPTION) 14.WHERE MORE THAN ONE CHECK-OUT AISLE IS PROVIDED, CHECK-OUT AISLES COMPLYING WITH 11B-904.3 CHECK-OUT AISLES SHALL BE IDENTIFIED BY A SIGN COMPLYING WITH 11B-904.3.4 IDENTIFICATION SIGN. WHERE CHECK-OUT AISLES ARE IDENTIFIED BY NUMBERS, LETTERS, OR FUNCTIONS, SIGNS IDENTIFYING CHECK-OUT AISLES COMPLYING WITH 11B-904.3 CHECK-OUT AISLES SHALL BE LOCATED IN THE SAME LOCATION AS THE CHECK-OUT AISLE IDENTIFICATION. §11B-216.11 (SEE EXCEPTION) 15. SIGNS IDENTIFYING THE TYPE OF ACCESS PROVIDED ON AMUSEMENT RIDES SHALL BE PROVIDED AT ENTRIES TO QUEUES AND WAITING LINES. IN ADDITION, WHERE ACCESSIBLE UNLOAD AREAS ALSO SERVE AS ACCESSIBLE LOAD AREAS, SIGNS INDICATING THE LOCATION OF THE ACCESSIBLE LOAD AND UNLOAD AREAS SHALL BE PROVIDED AT ENTRIES TO QUEUES AND WAITING LINES. SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.12 16. WHERE PROVIDED IN TRANSPORTATION FACILITIES, VARIABLE MESSAGE SIGNS CONVEYING TRANSPORTATION RELATED INFORMATION SHALL COMPLY WITH SECTION 11B-703.8. WHERE PROVIDED IN BUILDINGS THAT ARE DESIGNED AS EMERGENCY SHELTERS, VARIABLE MESSAGE SIGNS CONVEYING EMERGENCY RELATED INFORMATION SHALL COMPLY WITH SECTION 11B-703.8. §11B- 216.13 17.SIGNS SHALL COMPLY WITH 11B-703 SIGNS. WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ONE SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILE CHARACTERS, SHALL BE PROVIDED. §11B-703.1 a. SIGNS AS SPECIFIED IN SECTION 11B-703 SIGNS, OR IN OTHER SECTIONS OF THIS CODE, WHEN INCLUDED IN THE CONSTRUCTION OF NEW BUILDINGS OR FACILITIES, OR WHEN INCLUDED, ALTERED OR REPLACED DUE TO ADDITIONS, ALTERATIONS OR RENOVATIONS TO EXISTING BUILDINGS OR FACILITIES, AND WHEN A PERMIT IS REQUIRED, SHALL COMPLY WITH 11B-703.1.1.1 PLAN REVIEW AND 11B-703.1.1.2 INSPECTION. §11B-703.1.1 b. PLANS, SPECIFICATIONS OR OTHER INFORMATION INDICATING COMPLIANCE WITH THESE REGULATIONS SHALL BE SUBMITTED TO THE ENFORCING AGENCY FOR REVIEW AND APPROVAL. §11B-703.1.1.1 c. SIGNS AND IDENTIFICATION DEVICES SHALL BE FIELD INSPECTED AFTER INSTALLATION AND APPROVED BY THE ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER CHAPTER 1, DIVISION II, SECTION 111, OR FINAL APPROVAL WHERE NO CERTIFICATE OF OCCUPANCY IS ISSUED. THE INSPECTION SHALL INCLUDE, BUT NOT BE LIMITED TO, VERIFICATION THAT BRAILLE DOTS AND CELLS ARE PROPERLY SPACED AND THE SIZE, PROPORTION AND TYPE OF RAISED CHARACTERS ARE IN COMPLIANCE WITH THESE REGULATIONS. §11B-703.1.1.2 18.RAISED CHARACTERS SHALL COMPLY WITH 11B-703.2 RAISED CHARACTERS AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH 11B-703.3 BRAILLE. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH 11B-703.4 INSTALLATION HEIGHT AND LOCATION. §11B-703.2 a. RAISED CHARACTERS SHALL BE 1/32 INCH MINIMUM ABOVE THEIR BACKGROUND. §11B-703.2.1 b. CHARACTERS SHALL BE UPPERCASE. §11B-703.2.2 c. CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. §11B-703.2.3 d. CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER “O” IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER “I”. §11B-703.2.4 e. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8 INCH MINIMUM AND 2 INCHES MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER “I”. §11B-703.2.5 f. STROKE THICKNESS OF THE UPPERCASE LETTER “I” SHALL BE 15 PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER. §11B- 703.2.6 g. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT RAISED CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. WHERE CHARACTERS HAVE RECTANGULAR CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM. WHERE CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/16 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE BASE OF THE CROSS SECTIONS, AND 1/8 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE SEPARATED FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8 INCH MINIMUM. §11B-703.2.7 h. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHARACTERS WITHIN A MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE RAISED CHARACTER HEIGHT. §11B-703.2.8 i. TEXT SHALL BE IN A HORIZONTAL FORMAT. §11B-703.2.9 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NOT U S E D NOT U S E D NOT U S E D NOT U S E D NOT U S E D NOT U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NOT U S E D NO T U S E D NO T U S E D NO T U S E D NOT U S E D NO T U S E D NOT U S E D NOT U S E D G402 ACCESSIBILITY NOTES SIGNS (CONTINUED) 19. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH 11B-703.3 BRAILLE AND 11B-703.4 INSTALLATION HEIGHT AND LOCATION. §11B-703.3 a.BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11B-703.3.1. THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OF THE ALPHABET, INITIALS, AND ACRONYMS. §11B-703.3.1 b.BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. BRAILLE SHALL BE SEPARATED 3/8 INCH MINIMUM AND 1/2 INCH MAXIMUM FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH MINIMUM FROM RAISED BORDERS AND DECORATIVE ELEMENTS. §11B-703.3.2 (SEE EXCEPTION) 20. SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH 11B-703.4 INSTALLATION HEIGHT AND LOCATION. §11B-703.4 a.TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST TACTILE CHARACTER BRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER LINE OF RAISED CHARACTERS. §11B-703.4.1 (SEE EXCEPTION) WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. WHERE PROVIDED, SIGNS IDENTIFYING PERMANENT ROOMS AND SPACES SHALL BE LOCATED AT THE ENTRANCE TO, AND OUTSIDE OF THE ROOM OR SPACE. WHERE PROVIDED, SIGNS IDENTIFYING EXITS SHALL BE LOCATED AT THE EXIT DOOR WHEN APPROACHED IN THE DIRECTION OF EGRESS TRAVEL. §11B-703.4.2 (WITH EXCEPTION) 21. VISUAL CHARACTERS SHALL COMPLY WITH THE FOLLOWING, EXCEPT WHERE VISUAL CHARACTERS COMPLY WITH 11B-703.2 RAISED CHARACTERS AND ARE ACCOMPANIED BY BRAILLE COMPLYING WITH 11B-703.3 BRAILLE, THEY SHALL NOT BE REQUIRED TO COMPLY WITH 11B-703.5.2 THROUGH 11B-703.5.6, 11B-703.5.8 AND 11B-703.5.9: a.CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. §11B-703.5.1 b.CHARACTERS SHALL BE UPPERCASE OR LOWERCASE OR A COMBINATION OF BOTH. §11B-703.5.2 c.CHARACTERS SHALL BE CONVENTIONAL IN FORM. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. §11B-703.5.3 d.CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER “O” IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER “I”. §11B-703.5.4 e.MINIMUM CHARACTER HEIGHT SHALL COMPLY WITH TABLE 11B-703.5.5. VIEWING DISTANCE SHALL BE MEASURED AS THE HORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN OBSTRUCTION PREVENTING FURTHER APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE BASED ON THE UPPERCASE LETTER “I”. §11B-703.5.5 (SEE EXCEPTION) f.VISUAL CHARACTERS SHALL BE 40 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-703.5.6 (SEE EXCEPTIONS) g.STROKE THICKNESS OF THE UPPERCASE LETTER “I” SHALL BE 10 PERCENT MINIMUM AND 20 PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER. §11B-703.5.7 h.CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT CHARACTERS, EXCLUDING WORD SPACES. SPACING BETWEEN INDIVIDUAL CHARACTERS SHALL BE 10 PERCENT MINIMUM AND 35 PERCENT MAXIMUM OF CHARACTER HEIGHT. §11B-703.5.8 i.SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF CHARACTERS WITHIN A MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE CHARACTER HEIGHT. §11B-703.5.9 j.TEXT SHALL BE IN A HORIZONTAL FORMAT. §11B-703.5.10 22. PICTOGRAMS SHALL COMPLY WITH THE FOLLOWING: a.PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. §11B-703.6.1 b.PICTOGRAMS AND THEIR FIELD SHALL HAVE A NON-GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH THEIR FIELD WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. §11B-703.6.2 c.PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. TEXT DESCRIPTORS SHALL COMPLY WITH 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.4 INSTALLATION HEIGHT AND LOCATION. §11B- 703.6.3 23. SYMBOLS OF ACCESSIBILITY AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER A LIGHT SYMBOL ON A DARK BACKGROUND OR A DARK SYMBOL ON A LIGHT BACKGROUND. §11B-703.7.1 24. SYMBOLS SHALL COMPLY WITH THE FOLLOWING: a.THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH FIGURE 11B-703.7.2.1 ISA. THE SYMBOL SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE COLOR BLUE SHALL APPROXIMATE FS 15090 IN FEDERAL STANDARD 595C. §11B-703.7.2.1 (SEE EXCEPTIONS) 1) THE APPROPRIATE ENFORCEMENT AGENCY MAY APPROVE OTHER COLORS PROVIDED THE SYMBOL CONTRAST IS LIGHT ON DARK OR DARK ON LIGHT. 2) ON THE ACCESSIBILITY FUNCTION BUTTON ON HALL CALL CONSOLES IN A DESTINATION-ORIENTED ELEVATOR SYSTEM THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE A WHITE SYMBOL ON A BLACK BACKGROUND. b.THE INTERNATIONAL SYMBOL OF TTY SHALL COMPLY WITH FIGURE 11B-703.7.2.2. c.TELEPHONES WITH A VOLUME CONTROL SHALL BE IDENTIFIED BY A PICTOGRAM OF A TELEPHONE HANDSET WITH RADIATING SOUND WAVES ON A SQUARE FIELD SUCH AS SHOWN IN FIGURE 11B-703.7.2.3. d.ASSISTIVE LISTENING SYSTEMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS COMPLYING WITH FIGURE 11B-703.7.2.4. e.ROOMS, FACILITIES AND PATHS OF TRAVEL THAT ARE ACCESSIBLE TO AND USABLE BY PEOPLE WHO ARE ADVERSELY IMPACTED BY AIRBORNE CHEMICALS OR PARTICULATE(S) AND/OR THE USE OF ELECTRICAL FIXTURES AND/OR DEVICES SHALL BE IDENTIFIED BY THE CLEANER AIR SYMBOL COMPLYING WITH FIGURE 11B-703.7.2.5. THIS SYMBOL IS TO BE USED STRICTLY FOR PUBLICLY FUNDED FACILITIES OR ANY FACILITIES LEASED OR RENTED BY STATE OF CALIFORNIA, NOT CONCESSIONAIRES. f.DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS. THE SYMBOL SHALL BE MOUNTED AT 58 INCHES MINIMUM AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED FROM THE CENTERLINE OF THE SYMBOL. WHERE A DOOR IS PROVIDED THE SYMBOL SHALL BE MOUNTED WITHIN 1 INCH OF THE VERTICAL CENTERLINE OF THE DOOR. §11B-703.7.2.6 (SEE EXCEPTION) g.MEN'S TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE, ¼ INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.1 h.WOMEN'S TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, ¼ INCH THICK AND 12 INCHES IN DIAMETER. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.2 i.UNISEX TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, ¼ INCH THICK AND 12 INCHES IN DIAMETER WITH A ¼ INCH THICK TRIANGLE WITH A VERTEX POINTING UPWARD SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12-INCH DIAMETER. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. 11B-703.7.2.6.3 j.EDGES OF SIGNS SHALL BE ROUNDED, CHAMFERED OR EASED. CORNERS OF SIGNS SHALL HAVE A MINIMUM RADIUS OF ⅛ INCH. §11B-703.7.2.6.4 k.POLE-SUPPORTED PEDESTRIAN TRAFFIC-CONTROL BUTTONS SHALL BE IDENTIFIED WITH COLOR CODING CONSISTING OF A TEXTURED HORIZONTAL YELLOW BAND 2 INCHES IN WIDTH ENCIRCLING THE POLE, AND A 1-INCH-WIDE DARK BORDER BAND ABOVE AND BELOW THIS YELLOW BAND. COLOR CODING SHALL BE PLACED IMMEDIATELY ABOVE THE CONTROL BUTTON. CONTROL BUTTONS SHALL BE LOCATED NO HIGHER THAN 48 INCHES ABOVE THE GROUND SURFACE ADJACENT TO THE POLE. §11B-703.7.2 F. ELEVATORS & LIFTS ELEVATORS 1.ELEVATORS PROVIDED FOR PASSENGERS SHALL COMPLY WITH 11B-407. WHERE MULTIPLE ELEVATORS ARE PROVIDED, EACH ELEVATOR SHALL COMPLY WITH 11B-407 ELEVATORS; (SEE EXCEPTIONS). §11B-206.6 2.WHERE ELEMENTS OF EXISTING ELEVATORS ARE ALTERED, THE SAME ELEMENT SHALL ALSO BE ALTERED IN ALL ELEVATORS THAT ARE PROGRAMMED TO RESPOND TO THE SAME HALL CALL CONTROL AS THE ALTERED ELEVATOR AND SHALL COMPLY WITH THE REQUIREMENTS OF 11B-407 ELEVATORS FOR THE ALTERED ELEMENT. §11B-206.6.1 EXCEPTION: WHERE A GROUP OF EXISTING ELEVATORS ARE ALTERED INTO A DESTINATION-ORIENTED ELEVATOR SYSTEM, OR WHERE ELEMENTS OF EXISTING DESTINATION-ORIENTED ELEVATORS ARE ALTERED, THE SAME ELEMENTS SHALL ALSO BE ALTERED IN ALL ELEVATORS THAT ARE PROGRAMMED TO RESPOND TO THE SAME CALL CONSOLE OR GROUP OF CALL CONSOLES AND SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 11B-411 FOR THE ALTERED ELEMENTS. 3.ELEVATORS SHALL COMPLY WITH 11B-407 ELEVATORS AND WITH ASME A17.1. THEY SHALL BE PASSENGER ELEVATORS AS CLASSIFIED BY ASME A17.1. ELEVATOR OPERATION SHALL BE AUTOMATIC. WHEN THE ONLY ELEVATORS PROVIDED FOR USE BY THE PUBLIC AND EMPLOYEES ARE COMBINATION PASSENGER AND FREIGHT ELEVATORS, THEY SHALL COMPLY WITH 11B-407 ELEVATORS AND WITH ASME A17.1. §11B-407.1, §11B-407.1.1 4.WHERE ELEVATOR CALL BUTTONS OR KEYPADS ARE PROVIDED, THEY SHALL COMPLY WITH 11B-407.2.1 CALL CONTROLS AND 11B-309.4 OPERATION. §11B-407.2.1 5.CALL BUTTONS AND KEYPADS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN 11B-308 REACH RANGES, MEASURED TO THE CENTERLINE OF THE HIGHEST OPERABLE PART. §11B-407.2.1.1 6.CALL BUTTONS SHALL HAVE SQUARE SHOULDERS, BE ¾ INCH MINIMUM IN THE SMALLEST DIMENSION AND SHALL BE RAISED ⅛ INCH PLUS OR MINUS 1/32 INCH ABOVE THE SURROUNDING SURFACE. THE BUTTONS SHALL BE ACTIVATED BY A MECHANICAL MOTION THAT IS DETECTABLE. §11B-407.2.1.2 7. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 11B-305 CLEAR FLOOR OR GROUND SURFACE SHALL BE PROVIDED AT CALL CONTROLS. §11B-407.2.1.3 8. EXCEPT FOR DESTINATION-ORIENTED ELEVATORS, THE CALL BUTTON THAT DESIGNATES THE UP DIRECTION SHALL BE LOCATED ABOVE THE CALL BUTTON THAT DESIGNATES THE DOWN DIRECTION. §11B-407.2.1.4 9. EXCEPT AT DESTINATION-ORIENTED ELEVATORS, VISIBLE SIGNAL FIXTURES SHALL BE CENTERED AT 72 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. THE VISIBLE SIGNAL ELEMENTS SHALL BE A MINIMUM 2½ INCHES HIGH BY 2½ INCHES WIDE. SIGNALS SHALL BE VISIBLE FROM THE FLOOR AREA ADJACENT TO THE HALL CALL BUTTON. §11B-407.2.2.2, FIGURE 11B-407.2.2.2 10. FLOOR DESIGNATIONS COMPLYING WITH 11B-703.2 RAISED CHARACTERS AND 11B-703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND SHALL BE PROVIDED ON BOTH JAMBS OF ELEVATOR HOISTWAY ENTRANCES. FLOOR DESIGNATIONS SHALL BE PROVIDED IN BOTH RAISED CHARACTERS AND BRAILLE. RAISED CHARACTERS SHALL BE 2 INCHES HIGH. A RAISED STAR, PLACED TO THE LEFT OF THE FLOOR DESIGNATION, SHALL BE PROVIDED ON BOTH JAMBS AT THE MAIN ENTRY LEVEL. THE OUTSIDE DIAMETER OF THE STAR SHALL BE 2 INCHES AND ALL POINTS SHALL BE OF EQUAL LENGTH. RAISED CHARACTERS, INCLUDING THE STAR, SHALL BE WHITE ON A BLACK BACKGROUND. BRAILLE COMPLYING WITH SECTION 11B-703.3 BRAILLE SHALL BE PLACED BELOW THE CORRESPONDING RAISED CHARACTERS AND THE STAR. THE BRAILLE TRANSLATION FOR THE STAR SHALL BE “MAIN”. APPLIED PLATES ARE ACCEPTABLE IF THEY ARE PERMANENTLY FIXED TO THE JAMB. §11B- 407.2.3.1, FIGURE 11B-407.2.3.1 11. ELEVATOR DOORS SHALL BE THE HORIZONTAL SLIDING TYPE. CAR GATES SHALL BE PROHIBITED. §11B-407.3.1 12. ELEVATOR HOISTWAY AND CAR DOORS SHALL OPEN AND CLOSE AUTOMATICALLY. §11B-407.3.2 (SEE EXCEPTION) 13. THE WIDTH OF ELEVATOR DOORS SHALL COMPLY WITH TABLE 11B-407.4.1. §11B-407.3.6 (SEE EXCEPTION) 14. INSIDE DIMENSIONS OF ELEVATOR CARS AND CLEAR WIDTH OF ELEVATOR DOORS SHALL COMPLY WITH TABLE 11B-407.4.1. §11B-407.4.1 (SEE EXCEPTION) 15. FLOOR SURFACES IN ELEVATOR CARS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES AND 11B-303 CHANGES IN LEVEL. §11B-407.4.2 16. THE CLEARANCE BETWEEN THE CAR PLATFORM SILL AND THE EDGE OF ANY HOISTWAY LANDING SHALL BE 1¼ INCH MAXIMUM. §11B- 407.4.3 17. ELEVATOR CAR CONTROLS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN 11B-308 REACH RANGES. §11B-407.4.6, SEE EXCEPTIONS AS APPLICABLE. 18. CAR CONTROL BUTTONS WITH FLOOR DESIGNATIONS SHALL COMPLY WITH THE FOLLOWING: §11B-407.4.6.2 a.BUTTONS SHALL HAVE SQUARE SHOULDERS, BE 3/4 INCH MINIMUM IN THEIR SMALLEST DIMENSION AND BE RAISED 1/8 INCH PLUS OR MINUS 1/32 INCH ABOVE THE SURROUNDING SURFACE. §11B-407.4.6.2.1 b.BUTTONS SHALL BE ARRANGED WITH NUMBERS IN ASCENDING ORDER. WHEN TWO OR MORE COLUMNS OF BUTTONS ARE PROVIDED THEY SHALL READ FROM LEFT TO RIGHT. §11B-407.4.6.2.2 c.CAR CONTROL BUTTONS SHALL BE ILLUMINATED. §11B-407.4.6.2.3 d.CAR CONTROL BUTTONS SHALL BE ACTIVATED BY A MECHANICAL MOTION THAT IS DETECTABLE. §11B-407.4.6.2.4 19. EMERGENCY CONTROL BUTTONS SHALL HAVE THEIR CENTERLINES 35 INCHES MINIMUM ABOVE THE FINISH FLOOR. §11B-407.4.6.4.1 20.EMERGENCY CONTROLS, INCLUDING THE EMERGENCY ALARM, SHALL BE GROUPED AT THE BOTTOM OF THE PANEL. §11B-407.4.6.4.2 20.1.CAR CONTROL BUTTONS SHALL COMPLY WITH THE FOLLOWING: §11B-407.4.7.1 a.CONTROL BUTTONS SHALL BE IDENTIFIED BY RAISED CHARACTERS OR SYMBOLS, WHITE ON A BLACK BACKGROUND, COMPLYING WITH 11B-703.2 RAISED CHARACTERS AND BRAILLE COMPLYING WITH 11B-703.3 BRAILLE. §11B-407.4.7.1.1 b.RAISED CHARACTERS OR SYMBOLS AND BRAILLE DESIGNATIONS SHALL BE PLACED IMMEDIATELY TO THE LEFT OF THE CONTROL BUTTON TO WHICH THE DESIGNATIONS APPLY. §11B-407.4.7.1.2 c.THE CONTROL BUTTON FOR THE EMERGENCY STOP, ALARM, DOOR OPEN, DOOR CLOSE, MAIN ENTRY FLOOR, AND PHONE, SHALL BE IDENTIFIED WITH RAISED SYMBOLS AND BRAILLE AS SHOWN IN TABLE 11B-407.4.7.1.3. §11B-407.4.7.1.3, TABLE 11B- 407.4.7.1.3 d.BUTTONS WITH FLOOR DESIGNATIONS SHALL BE PROVIDED WITH VISIBLE INDICATORS TO SHOW THAT A CALL HAS BEEN REGISTERED. THE VISIBLE INDICATION SHALL EXTINGUISH WHEN THE CAR ARRIVES AT THE DESIGNATED FLOOR. §11B-407.4.7.1.4 e.A MINIMUM CLEAR SPACE OF 3/8 INCH OR OTHER SUITABLE MEANS OF SEPARATION SHALL BE PROVIDED BETWEEN ROWS OF CONTROL BUTTONS. §11B-407.4.7.1.5 22.KEYPADS SHALL BE IDENTIFIED BY CHARACTERS COMPLYING WITH 11B-703.5 VISUAL CHARACTERS AND SHALL BE CENTERED ON THE CORRESPONDING KEYPAD BUTTON. THE NUMBER FIVE KEY SHALL HAVE A SINGLE RAISED DOT. THE DOT SHALL BE 0.118 INCH TO 0.120 INCH BASE DIAMETER AND IN OTHER ASPECTS COMPLY WITH TABLE 11B-703.3.1. §11B-407.4.7.2 23.AUDIBLE AND VISIBLE CAR POSITION INDICATORS SHALL BE PROVIDED IN ELEVATOR CARS. CHARACTERS SHALL BE ½ INCH HIGH MINIMUM. INDICATORS SHALL BE LOCATED ABOVE THE CAR CONTROL PANEL OR ABOVE THE DOOR. §11B-407.4.8 24.EMERGENCY TWO-WAY COMMUNICATION SYSTEMS SHALL COMPLY WITH 11B-308 REACH RANGES. RAISED SYMBOLS OR CHARACTERS, WHITE ON A BLACK BACKGROUND, AND BRAILLE SHALL BE PROVIDED ADJACENT TO THE DEVICE AND SHALL COMPLY WITH 11B-703.2 RAISED CHARACTERS AND 11B-703.3 BRAILLE. EMERGENCY TWO-WAY COMMUNICATION SYSTEMS BETWEEN THE ELEVATOR AND A POINT OUTSIDE THE HOISTWAY SHALL COMPLY WITH ASME A17.1. §11B-407.4.9 25.SUPPORT RAILS SHALL BE PROVIDED ON AT LEAST ONE WALL OF THE CAR AND SHALL COMPLY WITH THE FOLLOWING: §11B-407.4.10 a.CLEARANCE BETWEEN SUPPORT RAILS AND ADJACENT SURFACES SHALL BE 1½ INCHES MINIMUM. TOP OF SUPPORT RAILS SHALL BE 31 INCHES MINIMUM TO 33 INCHES MAXIMUM ABOVE THE FLOOR OF THE CAR. THE ENDS OF THE SUPPORT RAIL SHALL BE 6 INCHES MAXIMUM FROM ADJACENT WALLS. §11B-407.4.10.1 b.SUPPORT RAILS SHALL BE SMOOTH AND ANY SURFACE ADJACENT TO THEM SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. §11B- 407.4.10.2 c.ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE SUPPORT RAIL, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. §11B-407.4.10.3 LIMITED-USE/LIMITED-APPLICATION ELEVATORS 26.LIMITED-USE/LIMITED-APPLICATION ELEVATORS SHALL COMPLY WITH 11B-408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS AND WITH ASME A17.1. THEY SHALL BE PASSENGER ELEVATORS AS CLASSIFIED BY ASME A17.1. ELEVATOR OPERATION SHALL BE AUTOMATIC. §11B-408.1 27.ELEVATOR CALL BUTTONS AND KEYPADS SHALL COMPLY WITH 11B-407.2.1 CALL CONTROLS. §11B-408.2.1 28.HALL SIGNALS SHALL COMPLY WITH 11B-407.2.2 HALL SIGNALS. §11B-408.2.2 29.SIGNS AT ELEVATOR HOISTWAYS SHALL COMPLY WITH 11B-407.2.3.1 FLOOR DESIGNATION. §11B-408.2.3 30.SLIDING HOISTWAY AND CAR DOORS SHALL COMPLY WITH 11B-407.3.1 THROUGH 11B-407.3.3 (TYPE, OPERATION, AND REOPENING DEVICE) AND 11B-408.4.1 CAR DIMENSIONS AND DOORS. §11B-408.3.1 LIMITED-USE/LIMITED-APPLICATION ELEVATORS (CONTINUED) 31. SWINGING HOISTWAY DOORS SHALL OPEN AND CLOSE AUTOMATICALLY AND SHALL COMPLY WITH 11B-404 DOORS, DOORWAYS, AND GATES, 11B-407.3.2 OPERATION, AND 11B-408.3.2 SWINGING DOORS. §11B-408.3.2 32. SWINGING DOORS SHALL BE POWER-OPERATED AND SHALL COMPLY WITH ANSI/BHMA A156.19 (1997 OR 2002 EDITION). §11B- 408.3.2.1 33. ELEVATOR CARS SHALL PROVIDE A CLEAR WIDTH 42 INCHES MINIMUM AND A CLEAR DEPTH 54 INCHES MINIMUM. CAR DOORS SHALL BE POSITIONED AT THE NARROW ENDS OF CARS AND SHALL PROVIDE 32 INCHES MINIMUM CLEAR WIDTH. §11B-408.4.1, FIGURE 11B- 408.4.1 (SEE EXCEPTION) 34. FLOOR SURFACES IN ELEVATOR CARS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES AND 11B-303 CHANGES IN LEVEL. §11B-408.4.2 35. THE PLATFORM TO HOISTWAY CLEARANCE SHALL COMPLY WITH 11B-407.4.3 PLATFORM TO HOISTWAY CLEARANCE. §11B-408.4.3 36. ELEVATOR CAR LEVELING SHALL COMPLY WITH 11B-407.4.4 LEVELING. §11B-408.4.4 37. ELEVATOR CAR ILLUMINATION SHALL COMPLY WITH 11B-407.4.5 ILLUMINATION. §11B-408.4.5 38. CONTROL PANELS SHALL BE CENTERED ON A SIDE WALL. §11B-408.4.6 39. DESIGNATIONS AND INDICATORS OF CAR CONTROLS SHALL COMPLY WITH 11B-407.4.7 DESIGNATIONS AND INDICATORS OF CAR CONTROLS. §11B-408.4.7 40. CAR EMERGENCY SIGNALING DEVICES COMPLYING WITH 11B-407.4.9 EMERGENCY COMMUNICATION SHALL BE PROVIDED. §11B- 408.4.8 PLATFORM LIFTS 1.PLATFORM LIFTS SHALL COMPLY WITH 11B-410 PLATFORM LIFTS. PLATFORM LIFTS SHALL BE PERMITTED AS A COMPONENT OF AN ACCESSIBLE ROUTE IN AN EXISTING BUILDING OR FACILITY OR IN NEW CONSTRUCTION AS FOLLOWS: §11B-206.7 a.PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE ACCESSIBLE ROUTES TO PERFORMANCE AREAS AND SPEAKERS' PLATFORMS. §11B- 206.7.1 b.PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE AN ACCESSIBLE ROUTE TO COMPLY WITH THE WHEELCHAIR SPACE DISPERSION AND LINE-OF-SIGHT REQUIREMENTS OF 11B-221 ASSEMBLY AREAS AND 11B-802 WHEELCHAIR SPACES, COMPANION SEATS, DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS. §11B-206.7.2 c.PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE AN ACCESSIBLE ROUTE TO INCIDENTAL SPACES WHICH ARE NOT PUBLIC USE SPACES AND WHICH ARE OCCUPIED BY FIVE PERSONS MAXIMUM. §11B-206.7.3 d.PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE AN ACCESSIBLE ROUTE TO: JURY BOXES AND WITNESS STANDS; RAISED COURTROOM STATIONS INCLUDING, JUDGES' BENCHES, CLERKS' STATIONS, BAILIFFS' STATIONS, DEPUTY CLERKS' STATIONS, AND COURT REPORTERS' STATIONS; AND TO DEPRESSED AREAS SUCH AS THE WELL OF A COURT. §11B-206.7.4 e.PLATFORM LIFTS SHALL BE PERMITTED WHERE EXISTING EXTERIOR SITE CONSTRAINTS MAKE USE OF A RAMP OR ELEVATOR INFEASIBLE. §11B-206.7.5 f.PLATFORM LIFTS SHALL BE PERMITTED TO CONNECT LEVELS WITHIN TRANSIENT LODGING GUEST ROOMS REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH 11B-806.2 GUEST ROOMS WITH MOBILITY FEATURES OR RESIDENTIAL DWELLING UNITS REQUIRED TO PROVIDE MOBILITY FEATURES COMPLYING WITH 11B-809.2 THROUGH 11B-809.4 AND ADAPTABLE FEATURES COMPLYING WITH CHAPTER 11A, DIVISION IV. §11B-206.7.6 g.PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE ACCESSIBLE ROUTES TO LOAD AND UNLOAD AREAS SERVING AMUSEMENT RIDES. §11B-206.7.7 h.PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE ACCESSIBLE ROUTES TO PLAY COMPONENTS OR SOFT CONTAINED PLAY STRUCTURES. §11B-206.7.8 i.PLATFORM LIFTS SHALL BE PERMITTED TO PROVIDE ACCESSIBLE ROUTES TO TEAM OR PLAYER SEATING AREAS SERVING AREAS OF SPORT ACTIVITY. §11B-206.7.9 2.FOR RECREATIONAL BOATING FACILITIES AND FISHING PIERS AND PLATFORMS, PLATFORM LIFTS SHALL BE PERMITTED TO BE USED INSTEAD OF GANGWAYS THAT ARE PART OF ACCESSIBLE ROUTES SERVING RECREATIONAL BOATING FACILITIES AND FISHING PIERS AND PLATFORMS. §11B- 206.7.10 3.PLATFORM LIFTS SHALL COMPLY WITH ASME A18.1 (1999 EDITION OR 2003 EDITION). PLATFORM LIFTS SHALL NOT BE ATTENDANT-OPERATED AND SHALL PROVIDE UNASSISTED ENTRY AND EXIT FROM THE LIFT. §11B-410.1 4.FLOOR SURFACES IN PLATFORM LIFTS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES AND 11B-303 CHANGES IN LEVEL. §11B-410.2 5.CLEAR FLOOR SPACE IN PLATFORM LIFTS SHALL COMPLY WITH 11B-305 CLEAR FLOOR OR GROUND SPACE. §11B-410.3 6.THE CLEARANCE BETWEEN THE PLATFORM SILL AND THE EDGE OF ANY RUNWAY LANDING SHALL BE 1¼ INCH MAXIMUM. §11B-410.4 7.CONTROLS FOR PLATFORM LIFTS SHALL COMPLY WITH 11B-309 OPERABLE PARTS. §11B-410.5 8.PLATFORM LIFTS SHALL HAVE LOW-ENERGY POWER-OPERATED DOORS OR GATES COMPLYING WITH 11B-404.3 AUTOMATIC AND POWER- ASSISTED DOORS AND GATES. DOORS SHALL REMAIN OPEN FOR 20 SECONDS MINIMUM. END DOORS AND GATES SHALL PROVIDE A CLEAR WIDTH 32 INCHES MINIMUM. SIDE DOORS AND GATES SHALL PROVIDE A CLEAR WIDTH 42 INCHES MINIMUM. §11B-410.6, FIGURE 11B-410.6 (SEE EXCEPTION) 9.THE MINIMUM SIZE OF LANDINGS AT PLATFORM LIFTS SHALL BE 60 INCHES BY 60 INCHES. §11B-410.7 10. A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS SHALL BE POSTED IN A CONSPICUOUS PLACE AT EACH LANDING AND WITHIN THE PLATFORM ENCLOSURE STATING “NO FREIGHT” AND INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B- 703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY. §11B-410.8 11. DESTINATION-ORIENTED ELEVATORS SHALL COMPLY WITH SECTION 11B-411 AND WITH ASME A17.1. THEY SHALL BE PASSENGER ELEVATORS AS CLASSIFIED BY ASME A17.1. ELEVATOR OPERATION SHALL BE AUTOMATIC. §11B-411.1 a.IN FACILITIES SERVED BY DESTINATION-ORIENTED ELEVATOR SYSTEMS, FLOOR DESIGNATIONS SHALL BE NUMERIC CHARACTERS ONLY. FLOOR DESIGNATIONS SHALL BE “ONE” (1) OR “ZERO” (0) AT THE MAIN ENTRY LEVEL AND SHALL INCREASE BY ONE FOR EACH SUCCESSIVE HIGHER STORY OR LEVEL. THE INITIAL FLOOR BELOW THE MAIN ENTRY LEVEL SHALL BE DESIGNATED “MINUS ONE” (-1) AND THE DESIGNATION FOR EACH SUCCESSIVE LOWER STORY OR LEVEL SHALL DECREASE BY ONE. STORIES OR LEVELS SHALL NOT BE DESIGNATED BY ALPHABETIC CHARACTERS. (SEE EXCEPTIONS) b.ELEVATOR CARS SHALL BE DESIGNATED WITH A SINGLE ALPHABETIC CHARACTER. (SEE EXCEPTION) 12. ELEVATOR LANDING REQUIREMENTS NEED TO COMPLY WITH THE FOLLOWING: §11B-411.2.1-§11B-411.2.2 a.HALL CONSOLES INCLUDING: LOCATION, KEYPADS, TOUCH SCREEN, ACCESSIBILITY, FUNCTION BUTTON, DISPLAY SCREEN, AUDIO OUTPUT, ARRANGEMENT, ADDITIONAL FEATURES, BUTTON REQUIREMENTS, IDENTIFICATION OF FLOORS SERVED, ELEVATOR CAR ASSIGNMENT. b.ELEVATOR CAR IDENTIFICATION AT CAR LANDINGS INCLUDING: VISIBLE IDENTIFICATION, VERBAL IDENTIFICATION, SIGNS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCES (FLOOR DESIGNATION SIGNS AND CAR DESIGNATION SIGNS). 13. ELEVATOR DOOR REQUIREMENTS NEED TO COMPLY WITH: TYPE, OPERATION, REOPENING DEVICE, HEIGHT, CONTACT, DURATION, DOOR DELAY, WIDTH. §11B-411.3 14. ELEVATOR CAR REQUIREMENTS NEED TO COMPLY WITH: §11B-411.4 a.CAR DIMENSIONS b.FLOOR SURFACES c.PLATFORM TO HOISTWAY CLEARANCE d.LEVELING e.ILLUMINATION f.ELEVATOR CAR CONTROLS g.DESIGNATIONS AND INDICATORS OF CAR CONTROL BUTTONS h.CAR POSITION INDICATORS i.EMERGENCY COMMUNICATION j.SUPPORT RAIL k.FLOOR DESTINATION INDICATORS G. RESTAURANTS, CAFETERIAS, BANQUET FACILITIES, BARS, PERFORMANCE AREAS, PRESS BOXES, EMPLOYEE AREAS 1.WITHIN A SITE. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. §11B-206.2.2 2.ENTRANCES SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 11B-206.4. ENTRANCE DOORS, DOORWAYS, AND GATES SHALL COMPLY WITH SECTION 11B-404 AND SHALL BE ON AN ACCESSIBLE ROUTE COMPLYING WITH SECTION 11B-402. §11B-206.4 3.WHERE TOILET ROOMS ARE PROVIDED, EACH TOILET ROOM SHALL COMPLY WITH SECTION 11B-603. WHERE BATHING ROOMS ARE PROVIDED, EACH BATHING ROOM SHALL COMPLY WITH SECTION 11B-603. §11B-213.2 4.IN RESTAURANTS, CAFETERIAS, BANQUET FACILITIES, BARS, AND SIMILAR FACILITIES, AN ACCESSIBLE ROUTE SHALL BE PROVIDED TO ALL FUNCTIONAL AREAS, INCLUDING RAISED OR SUNKEN AREAS, AND OUTDOOR AREAS. §11B-206.2.5 5.WHERE A CIRCULATION PATH DIRECTLY CONNECTS A PERFORMANCE AREA TO AN ASSEMBLY SEATING AREA, AN ACCESSIBLE ROUTE SHALL DIRECTLY CONNECT THE ASSEMBLY SEATING AREA WITH THE PERFORMANCE AREA. AN ACCESSIBLE ROUTE SHALL BE PROVIDED FROM PERFORMANCE AREAS TO ANCILLARY AREAS OR FACILITIES USED BY PERFORMERS UNLESS EXEMPTED BY 11B- 206.2.3 MULTI-STORY BUILDINGS AND FACILITIES, (SEE EXCEPTIONS 1 THROUGH 7). §11B-206.2.6 6.PRESS BOXES IN ASSEMBLY AREAS SHALL BE ON AN ACCESSIBLE ROUTE. §11B-206.2.7 (SEE EXCEPTIONS) 7.COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS SHALL COMPLY WITH 11B-402 ACCESSIBLE ROUTES. §11B-206.2.8 (SEE EXCEPTIONS) 8.NEWLY CONSTRUCTED COMMERCIAL PLACES OF PUBLIC AMUSEMENT SHALL PROVIDE NO FEWER THAN ONE ADULT CHANGING FACILITY IN COMPLIANCE WITH SECTION 11B-813. (SEE DEFINITION) 9.AT DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, KNEE CLEARANCE SHALL BE PROVIDED THAT IS 30 INCHES IN WIDTH AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND FOR A DEPTH OF AT LEAST 19 INCHES. §11B-306.3 DINING SURFACES, WORK SURFACES & WET BAR 10. DINING SURFACES AND WORK SURFACES SHALL COMPLY WITH 11B-902.2 AND 11B-902.3. §11B-902.1 11. A CLEAR FLOOR SPACE COMPLYING WITH 11B-305 POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH 11B-306 SHALL BE PROVIDED. §11B-902.2 12. THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-902.3 13. ACCESSIBLE DINING SURFACES AND WORK SURFACES FOR CHILDREN'S USE SHALL COMPLY WITH 11B-902.4. §11B-902.4 (SEE EXCEPTION) 14. WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL COMPLY WITH 11B-902. IN ADDITION, WHERE WORK SURFACES ARE PROVIDED FOR USE BY OTHER THAN EMPLOYEES, AT LEAST 5 PERCENT SHALL COMPLY WITH 11B-902. §11B-226.1 (SEE EXCEPTIONS) 15.DINING SURFACES AND WORK SURFACES REQUIRED TO COMPLY WITH 11B-902 SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING SURFACES AND WORK SURFACES FOR EACH TYPE OF SEATING IN A FUNCTIONAL AREA. WORK SURFACES REQUIRED TO COMPLY WITH 11B-902 SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING WORK SURFACES. §11B-226.2 16.WHERE FOOD OR DRINK IS SERVED FOR CONSUMPTION AT A COUNTER EXCEEDING 34 INCHES IN HEIGHT, A PORTION OF THE MAIN COUNTER 60 INCHES MINIMUM IN LENGTH SHALL BE PROVIDED IN COMPLIANCE WITH 11B-902.3. §11B-226.3 17. FOOD SERVICE LINES SHALL COMPLY WITH 11B-904.5. WHERE SELF-SERVICE SHELVES ARE PROVIDED, AT LEAST 50 PERCENT, BUT NO FEWER THAN ONE, OF EACH TYPE PROVIDED SHALL COMPLY WITH 11B-308. §11B-227.4 18. QUEUES AND WAITING LINES SERVICING COUNTERS OR CHECK-OUT AISLES REQUIRED TO COMPLY WITH 11B-904.3 OR 11B-904.4 SHALL COMPLY WITH 11B-403. §11B-227.5 19. COUNTERS IN FOOD SERVICE LINES SHALL COMPLY WITH 11B-904.5. §11B-904.5 1) SELF-SERVICE SHELVES AND DISPENSING DEVICES FOR TABLEWARE, DISHWARE, CONDIMENTS, FOOD AND BEVERAGES SHALL COMPLY WITH 11B-308. §11B-904.5.1 2) THE TOPS OF TRAY SLIDES SHALL BE 28 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-904.5.2 20.SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH SECTION 11B-904.4.1 OR 11B-904.4.2. THE ACCESSIBLE PORTION OF THE COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR SERVICE COUNTER TOP. §11B-904.4 (SEE EXCEPTION) a.A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES LONG MINIMUM AND 34 INCHES HIGH MAXIMUM ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 11B-305 SHALL BE POSITIONED FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH MINIMUM LENGTH OF COUNTER. §11B-904.4.1 (SEE EXCEPTION) OR b.A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES LONG MINIMUM AND 34 INCHES HIGH MAXIMUM SHALL BE PROVIDED. KNEE AND TOE SPACE COMPLYING WITH 11B-306 SHALL BE PROVIDED UNDER THE COUNTER. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 11B-305 SHALL BE POSITIONED FOR A FORWARD APPROACH TO THE COUNTER. §11B-904.4.2 I. AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES 1.ELECTRONIC INFORMATION PROCESSING DEVICES THAT ACCEPT OR DISPENSE CASH IN CONNECTION WITH A CREDIT, DEPOSIT OR CONVENIENCE ACCOUNT SHALL COMPLY WITH THE REQUIREMENTS FOR AUTOMATIC TELLER MACHINES (ATMS). §202, §11B-220.1 2.DEVICES USED FOR THE PURCHASE OF GOODS OR SERVICES THAT REQUIRE A PERSONAL IDENTIFICATION NUMBER (PIN), ZIP CODE OR SIGNATURE SHALL COMPLY WITH THE REQUIREMENTS FOR POINT-OF-SALE DEVICES (POS). §202, §11B-220.2 3.ALL AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES SHALL DISPLAY CHARACTERS IN A SANS SERIF FONT. CHARACTERS SHALL BE AT LEAST 3/16 INCH HIGH BASED ON THE UPPERCASE LETTER "I". CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. §11B-220, §11B-707.7.2 4.WALK-UP AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES SHALL COMPLY WITH ALL REQUIREMENTS OF SECTIONS 11B-305 CLEAR FLOOR OR GROUND SPACE AND 11B-309 OPERABLE PARTS. EACH OPERABLE PART SHALL BE ABLE TO BE DIFFERENTIATED BY SOUND OR TOUCH, WITHOUT ACTIVATION, UNLESS A CLEAR OR CORRECT KEY IS PROVIDED. §11B-220,11B-707 5.WHERE TWO OR MORE WALK-UP POINT-OF-SALE DEVICES ARE INSTALLED FOR USE WITH A SPECIFIC TYPE OF MOTOR FUEL, AT LEAST TWO FOR THAT FUEL TYPE SHALL COMPLY WITH ALL REQUIREMENTS OF SECTIONS 11B-305 CLEAR FLOOR OR GROUND SPACE AND 11B-309 OPERABLE PARTS. FUEL TYPES INCLUDE, BUT ARE NOT LIMITED TO, GASOLINE, DIESEL, COMPRESSED NATURAL GAS, METHANOL, OR ETHANOL. §11B-220.2 6.POINT-OF-SALE DEVICES AT ELECTRIC VEHICLE CHARGING STATIONS REQUIRED TO COMPLY WITH 11B-812 SHALL COMPLY WITH 11B- 812.10.3. §11B-220.2 7.DRIVE-UP ONLY AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES SHALL BE OPERABLE WITH ONE HAND WITHOUT REQUIRING TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST AND USE NO MORE THAN 5 POUNDS TO ACTIVATE OPERABLE PARTS. EACH OPERABLE PART SHALL BE ABLE TO BE DIFFERENTIATED BY SOUND OR TOUCH, WITHOUT ACTIVATION, UNLESS A CLEAR OR CORRECT KEY IS PROVIDED. §11B-707.3 8.POINT-OF-SALE DEVICES WHEN PROVIDED AT CHECK STANDS AND SALES AND SERVICE COUNTERS AND ALL AUTOMATIC TELLER MACHINES SHALL PROVIDE THE OPPORTUNITY FOR THE SAME DEGREE OF PRIVACY OF INPUT AND OUTPUT AVAILABLE TO ALL INDIVIDUALS. §11B-707.4, §11B-707.9.2 9.WHERE BINS ARE PROVIDED FOR ENVELOPES, WASTE PAPER, OR OTHER PURPOSES TO SERVE AUTOMATIC TELLER AND FARE MACHINES, AT LEAST ONE OF EACH TYPE SHALL COMPLY WITH THE REQUIREMENTS FOR CLEAR FLOOR SPACE, HEIGHT AND OPERABLE PARTS IN SECTION 11B-811 STORAGE. §11B-220.1 10.AUTOMATIC TELLER, FARE MACHINES AND POINT-OF-SALE DEVICES SHALL BE SPEECH ENABLED. SPEECH SHALL BE DELIVERED THROUGH A MECHANISM THAT IS READILY AVAILABLE TO ALL USERS, INCLUDING BUT NOT LIMITED TO, AN INDUSTRY STANDARD CONNECTOR OR A TELEPHONE HANDSET. SPEECH SHALL BE RECORDED OR DIGITIZED HUMAN, OR SYNTHESIZED. §11B-707.5 11.FOR AUTOMATIC TELLER, FARE MACHINES, AND POINT-OF-SALE DEVICES OPERATING INSTRUCTIONS AND ORIENTATION, VISIBLE TRANSACTION PROMPTS, USER INPUT VERIFICATION, ERROR MESSAGES, AND ALL DISPLAYED INFORMATION FOR FULL USE SHALL BE ACCESSIBLE TO AND INDEPENDENTLY USABLE BY INDIVIDUALS WITH VISION IMPAIRMENTS. §11B-707.5 12.SPEECH ON AUTOMATIC TELLER, FARE MACHINES, AND POINT-OF-SALES DEVICES SHALL BE CAPABLE OF BEING REPEATED OR INTERRUPTED. SPEECH OUTPUT FOR ANY SINGLE FUNCTION MAY BE AUTOMATICALLY INTERRUPTED WHEN A TRANSACTION IS SELECTED. VOLUME CONTROL SHALL BE PROVIDED FOR THE SPEECH FUNCTION. §11B-707.5.1 13.SPEECH OUTPUT DEVICES ON AUTOMATIC TELLER, FARE MACHINES AND POINT-OF-SALES DEVICES THAT PROVIDE RECEIPTS SHALL PROVIDE AUDIBLE BALANCE INQUIRY INFORMATION, ERROR MESSAGES, AND ALL OTHER INFORMATION ON THE PRINTED RECEIPT NECESSARY TO COMPLETE OR VERIFY THE TRANSACTION UNLESS OTHERWISE EXEMPTED. §11B-707.5.2 14.SPEECH OUTPUT DEVICES ON AUTOMATIC TELLER AND FARE MACHINES AND POINT-OF-SALE DEVICES THAT PROVIDE RECEIPTS SHALL NOT REQUIRE THE FOLLOWING TO BE AUDIBLE: MACHINE LOCATION, DATE AND TIME OF TRANSACTION, CUSTOMER ACCOUNT NUMBER, AND THE MACHINE IDENTIFIER; INFORMATION ON PRINTED RECEIPTS THAT DUPLICATES INFORMATION AVAILABLE ON-SCREEN; AND PRINTED COPIES OF BANK STATEMENTS AND CHECKS. §11B-707.5.2 15.AUTOMATIC TELLER AND FARE MACHINES AND POINT-OF-SALE DEVICES SHALL PROVIDE AT LEAST ONE TACTILELY DISCERNIBLE INPUT CONTROL FOR EACH FUNCTION. WHERE PROVIDED, KEY SURFACES NOT ON ACTIVE AREAS OF DISPLAY SCREENS, SHALL BE RAISED ABOVE SURROUNDING SURFACES. WHERE MEMBRANE KEYS ARE THE ONLY METHOD OF INPUT, EACH SHALL BE TACTILELY DISCERNIBLE FROM SURROUNDING SURFACES AND ADJACENT KEYS. §11B-707.6.1 16.NUMERIC KEYS ON AUTOMATIC TELLER AND FARE MACHINES SHALL BE ARRANGED IN A 12-KEY ASCENDING OR DESCENDING TELEPHONE KEYPAD LAYOUT. THE NUMBER FIVE KEY SHALL BE TACTILELY DISTINCT FROM THE OTHER KEYS. §11B-707.6.2 17.FUNCTION KEYS ON AUTOMATIC TELLER AND FARE MACHINES SHALL CONTRAST VISUALLY FROM BACKGROUND SURFACES. CHARACTERS AND SYMBOLS ON KEY SURFACES SHALL CONTRAST VISUALLY FROM KEY SURFACES. VISUAL CONTRAST SHALL BE EITHER LIGHT-ON-DARK OR DARK-ON-LIGHT EXCEPT FOR TACTILE SYMBOLS. §11B-707.6.3.1 18.FUNCTION KEY SURFACES ON AUTOMATIC TELLER, FARE MACHINES AND POINT-OF-SALE DEVICES SHALL HAVE TACTILE SYMBOLS AS FOLLOWS: ENTER OR PROCEED KEY: RAISED CIRCLE; CLEAR OR CORRECT KEY: RAISED LEFT ARROW; CANCEL KEY: RAISED LETTER EX; ADD VALUE KEY: RAISED PLUS SIGN; DECREASE VALUE KEY: RAISED MINUS SIGN. §11B-707.6.3 19.AT LEAST 50 PERCENT OF WALK-UP AUTOMATIC TELLER, FARE MACHINES AND POINT-OF-SALE DEVICES SHALL HAVE DISPLAY SCREENS THAT ARE VISIBLE FROM A POINT LOCATED 40 INCHES ABOVE THE CENTER OF THE CLEAR FLOOR SPACE IN FRONT OF THE MACHINE. §11B-220.1, §11B-707.7.1 20.WHERE DISPLAY SCREENS FOR AUTOMATIC TELLER, FARE MACHINES OR POINT-OF-SALE DEVICES ARE MOUNTED VERTICALLY OR NO MORE THAN 30 DEGREES TIPPED AWAY FROM THE VIEWER, THE CENTER LINE OF THE DISPLAY SCREEN AND OTHER DISPLAY DEVICES SHALL BE NO MORE THAN 52 INCHES ABOVE THE FLOOR OR GROUND SURFACE. §11B-707.7.1.1 21.WHERE DISPLAY SCREENS FOR AUTOMATIC TELLER, FARE MACHINES OR POINT-OF-SALE DEVICES ARE MOUNTED BETWEEN 30 DEGREES AND 60 DEGREES TIPPED AWAY FROM THE VIEWER, THE CENTER LINE OF THE DISPLAY SCREEN AND OTHER DISPLAY DEVICES SHALL BE NO MORE THAN 44 INCHES ABOVE THE FLOOR OR GROUND SURFACE. §11B-707.7.1.2 22.WHERE DISPLAY SCREENS FOR AUTOMATIC TELLER OR FARE MACHINES ARE MOUNTED NO LESS THAN 60 DEGREES AND NO MORE THAN 90 DEGREES (HORIZONTAL) TIPPED AWAY FROM THE VIEWER, THE CENTER LINE OF THE DISPLAY SCREEN AND OTHER DISPLAY DEVICES SHALL BE NO MORE THAN 34 INCHES ABOVE THE FLOOR OR GROUND SURFACE. §11B-707.7.1.3 H. ASSEMBLY AREAS 8.WHEELCHAIR SPACES SHALL BE PROVIDED IN EACH SPECIALTY SEATING AREA THAT PROVIDES SPECTATORS WITH DISTINCT SERVICES OR AMENITIES THAT GENERALLY ARE NOT AVAILABLE TO OTHER SPECTATORS. THE NUMBER OF WHEELCHAIR SPACES PROVIDED IN SPECIALTY SEATING AREAS SHALL BE INCLUDED IN, RATHER THAN BE IN ADDITION TO, THE TOTAL NUMBER OF WHEELCHAIR SPACES REQUIRED BY TABLE 11B-221.2.1.1. §11B-221.2.1.6 9.WHEELCHAIR SPACES SHALL BE AN INTEGRAL PART OF THE SEATING PLAN. §11B-221.2.2 10.WHEELCHAIR SPACES SHALL PROVIDE LINES OF SIGHT COMPLYING WITH 11B-802.2 LINES OF SIGHT AND BE DISPERSED HORIZONTALLY AND VERTICALLY. §11B-221.2.3, §11B-221.2.3.1, §11B-221.2.3.2 11.PROVIDE SECTION(S) TO SHOW THAT LINES OF SIGHT TO THE SCREEN, PERFORMANCE AREA, OR PLAYING FIELD FOR SPECTATORS IN WHEELCHAIR SPACES COMPLY WITH 11B-802.2 LINES OF SIGHT. 12.AT LEAST ONE COMPANION SEAT COMPLYING WITH 11B-802.3 COMPANION SEATS SHALL BE PROVIDED IMMEDIATELY ADJACENT TO EACH WHEELCHAIR SPACE REQUIRED BY 11B-221.2.1 NUMBER AND LOCATION. §11B-221.3 13.IN ROW SEATING, COMPANION SEATS SHALL BE LOCATED TO PROVIDE SHOULDER ALIGNMENT WITH ADJACENT WHEELCHAIR SPACES. §11B-802.3.1 14.COMPANION SEATS SHALL BE EQUIVALENT IN SIZE, QUALITY, COMFORT, AND AMENITIES TO THE SEATING IN THE IMMEDIATE AREA. COMPANION SEATS SHALL BE PERMITTED TO BE MOVEABLE. §11B-802.3.2 15.AT LEAST 5 PERCENT OF THE TOTAL NUMBER OF AISLE SEATS PROVIDED SHALL COMPLY WITH THE FOLLOWING SECTION 11B-802.4 AND SHALL BE THE AISLE SEATS LOCATED CLOSEST TO ACCESSIBLE ROUTES. §11B-221.4 a.WHERE ARMRESTS ARE PROVIDED ON SEATING IN THE AREA, SHOW FOLDING OR RETRACTABLE ARMRESTS ON THE AISLE SIDE OF DESIGNATED AISLE SEATS. §11B-802.4.1 b.EACH DESIGNATED AISLE SEAT SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1. c.SIGNAGE COMPLYING WITH SECTION 11B-703.5 SHALL BE POSTED AT THE TICKET OFFICE NOTIFYING PATRONS OF THEIR AVAILABILITY. §11B-802.4.2 16.AT LEAST 1 PERCENT OF THE TOTAL NUMBER OF SEATS, AND NO FEWER THAN TWO, SHALL BE SEMI-AMBULANT SEATS WITH AT LEAST 24 INCHES CLEAR LEG SPACE BETWEEN THE FRONT OF THE SEAT TO THE NEAREST OBSTRUCTION OR THE BACK OF THE SEAT IN FRONT. §11B-221.6 & §11B-802.5 I. AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES (CONTINUED) 23. AUTOMATIC TELLER AND FARE MACHINES SHALL HAVE INSTRUCTIONS FOR INITIATING THE SPEECH MODE PROVIDED IN CONTRACTED (GRADE 2) BRAILLE. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH THE BRAILLE DIMENSION REQUIREMENTS OF TABLE 11B-703.3.1. BRAILLE UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OF THE ALPHABET, INITIALS, AND ACRONYMS. §11B-707.8 24. POINT-OF-SALE SYSTEMS THAT INCLUDE A VIDEO TOUCH SCREEN OR ANY OTHER NON-TACTILE KEYPAD SHALL BE EQUIPPED WITH A TACTILELY DISCERNIBLE NUMERICAL KEYPAD, RADIO FREQUENCY IDENTIFICATION DEVICE, FINGERPRINT BIOMETRICS OR OTHER ACCESSIBLE EQUIVALENT TECHNOLOGY. §11B-220.2, §11B-707.9 25. POINT-OF-SALE SYSTEMS THAT INCLUDE A VIDEO TOUCH SCREEN OR ANY OTHER NON-TACTILE KEYPAD SHALL ENABLE A VISUALLY IMPAIRED PERSON TO ENTER HIS OR HER OWN PERSONAL IDENTIFICATION NUMBER OR ANY OTHER PERSONAL INFORMATION NECESSARY TO PROCESS THE TRANSACTION IN A MANNER THAT PROVIDES THE OPPORTUNITY FOR THE SAME DEGREE OF PRIVACY INPUT AND OUTPUT AVAILABLE TO ALL INDIVIDUALS. §11B-220.2, §11B-707.9 26. TACTILELY DISCERNIBLE NUMERICAL KEYPADS ON POINT-OF-SALE SYSTEMS SHALL BE SIMILAR TO A TELEPHONE KEYPADS CONTAINING A RAISED DOT ON THE NUMBER 5 KEY WITH A DOT BASE DIAMETER BETWEEN 1.5 TO 1.6 MM AND A HEIGHT BETWEEN 0.6 TO 0.9 MM. §11B-707.9.1.1 DRESSING, FITTING, AND LOCKER ROOMS 27. WHERE DRESSING ROOMS, FITTING ROOMS, OR LOCKER ROOMS ARE PROVIDED, AT LEAST 5 PERCENT, BUT NO FEWER THAN ONE, OF EACH TYPE OF USE IN EACH CLUSTER PROVIDED SHALL COMPLY WITH THE FOLLOWING: §11B-222.1 AND §11B-803 a.A 60 INCH DIAMETER CIRCULAR TURNING SPACE OR A T-SHAPED TURNING SPACE COMPLYING WITH 11B-304.3.2 T-SHAPED SPACES SHALL BE PROVIDED WITHIN THE ROOM. §11B-803.2 b.DOORS SHALL NOT SWING INTO THE ROOM UNLESS A TURNING SPACE IS PROVIDED BEYOND THE ARC OF THE DOOR SWING. §11B- 803.3 c.A BENCH COMPLYING WITH 11B-903 BENCHES SHALL BE PROVIDED WITHIN THE ROOM. THE BENCH SEAT SHALL BE 48 INCH MINIMUM LONG, 20 TO 24 INCH DEEP, AND A CLEAR FLOOR SPACE COMPLYING WITH 11B-305 CLEAR FLOOR OR GROUND SPACE SHALL BE PROVIDED AT THE END OF THE BENCH SEAT AND PARALLEL TO THE SHORT AXIS OF THE BENCH. THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL ALONG ITS LONG DIMENSION. THE TOP OF THE BENCH SEAT SHALL BE 17 TO 19 INCHES ABOVE THE FINISH FLOOR. BENCHES SHALL BE AFFIXED TO THE WALL OR FLOOR. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE SEAT, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. §11B-803.4, §11B-903. d.COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN 11B-308 AND SHALL NOT BE LOCATED ABOVE THE BENCH OR OTHER SEATING IN THE ROOM. §11B-803.5 e.SHELVES SHALL BE 40 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-803.5. f.FULL-LENGTH MIRRORS, AT LEAST 18 INCHES WIDE BY 54 INCHES HIGH, SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 20 INCHES MAXIMUM ABOVE THE FINISH FLOOR. MIRRORS SHALL BE MOUNTED IN A POSITION AFFORDING A VIEW TO A PERSON ON THE BENCH AS WELL AS TO A PERSON IN A STANDING POSITION. §11B-803.6 BENCHES 28.CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 11B-305 SHALL BE PROVIDED AND SHALL BE POSITIONED AT THE END OF THE BENCH SEAT AND PARALLEL TO THE SHORT AXIS OF THE BENCH. §11B-903.2 29.BENCHES SHALL HAVE SEATS THAT ARE 48 INCHES LONG MINIMUM AND 20 INCHES DEEP MINIMUM AND 24 INCHES DEEP MAXIMUM. §11B-903.3 30.THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL ALONG ITS LONG DIMENSION. BACK SUPPORT SHALL BE 48 INCHES LONG MINIMUM AND SHALL EXTEND FROM A POINT 2 INCHES MAXIMUM ABOVE THE SEAT SURFACE TO A POINT 18 INCHES MINIMUM ABOVE THE SEAT SURFACE. BACK SUPPORT SHALL BE 2½ INCHES MAXIMUM FROM THE REAR EDGE OF THE SEAT MEASURED HORIZONTALLY. §11B-903.4 31.THE TOP OF THE BENCH SEAT SURFACE SHALL BE 17 INCHES MINIMUM AND 19 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-903.5 32.BENCHES SHALL BE AFFIXED TO THE WALL OR FLOOR. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS IS APPLIED AT ANY POINT ON THE SEAT, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE. §11B-903.6 33.WHERE INSTALLED IN WET LOCATIONS, THE SURFACE OF THE SEAT SHALL BE SLIP RESISTANT AND SHALL NOT ACCUMULATE WATER. §11B-903.7 CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS 34.WHERE PROVIDED, CHECK-OUT AISLES, SALES COUNTERS, SERVICE COUNTERS, FOOD SERVICE LINES, QUEUES, AND WAITING LINES SHALL COMPLY WITH 11B-227 AND 11B-904. §11B-227.1 35.WHERE CHECK-OUT AISLES ARE PROVIDED, CHECK-OUT AISLES COMPLYING WITH 11B-904.3 SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 11B-227.2. WHERE CHECK-OUT AISLES SERVE DIFFERENT FUNCTIONS, CHECK-OUT AISLES COMPLYING WITH 11B-904.3 SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 11B-227.2 FOR EACH FUNCTION. WHERE CHECK-OUT AISLES ARE DISPERSED THROUGHOUT THE BUILDING OR FACILITY, CHECK-OUT AISLES COMPLYING WITH 11B-904.3 SHALL BE DISPERSED. WHEN NOT ALL CHECK-OUT AISLES ARE ACCESSIBLE, ACCESSIBLE CHECK-OUT AISLES SHALL BE IDENTIFIED BY A SIGN COMPLYING WITH 11B-904.3.4. §11B-227.2 (SEE EXCEPTION) 36.PROVIDE A NOTE ON PLANS: “OPERATIONAL PROCEDURES ARE OFTEN NECESSARY TO ENSURE THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY REQUIREMENTS ARE MET. WHEN CHECK-OUT AISLES ARE OPEN FOR CUSTOMER USE, THE BUSINESS SHOULD ENSURE THAT A MINIMUM OF ONE ACCESSIBLE CHECK-OUT AISLE IS ALWAYS AVAILABLE FOR USE BY PERSONS WITH DISABILITIES. AS CHECK- OUT AISLES ARE OPENED AND CLOSED BASED ON FLUCTUATING CUSTOMER LEVELS, THE BUSINESS SHOULD ENSURE THAT THE NUMBER OF ACCESSIBLE CHECK-OUT AISLES AVAILABLE COMPLIES WITH TABLE 11B-227.2. 37.WHERE CHECK-OUT AISLES ARE ALTERED, AT LEAST ONE OF EACH CHECK-OUT AISLE SERVING EACH FUNCTION SHALL COMPLY WITH 11B-904.3 UNTIL THE NUMBER OF CHECK-OUT AISLES COMPLIES WITH 11B-227.2. §11B-227.2.1 38.ALL PORTIONS OF COUNTERS REQUIRED TO COMPLY WITH 11B-904 SHALL BE LOCATED ADJACENT TO A WALKING SURFACE COMPLYING WITH 11B-403. §11B-904.2 39.CHECK-OUT AISLES SHALL COMPLY WITH THE FOLLOWING: a.AISLES SHALL COMPLY WITH 11B-403. §11B-904.3.1 b.THE COUNTER SURFACE HEIGHT SHALL BE 38 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. THE TOP OF THE COUNTER EDGE PROTECTION SHALL BE 2 INCHES MAXIMUM ABOVE THE TOP OF THE COUNTER SURFACE ON THE AISLE SIDE OF THE CHECK- OUT COUNTER. §11B-904.3.2 c.WHERE PROVIDED, CHECK WRITING SURFACES SHALL COMPLY WITH 11B-902.3. §11B-904.3.3 d.WHEN NOT ALL CHECK-OUT AISLES ARE ACCESSIBLE, ACCESSIBLE CHECK-OUT AISLES SHALL BE IDENTIFIED BY A SIGN CLEARLY VISIBLE TO A PERSON IN A WHEELCHAIR DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1. THE SIGN SHALL BE A MINIMUM OF 4 INCHES BY 4 INCHES. §11B-904.3.4 40.SALES COUNTERS AND SERVICE COUNTERS SHALL COMPLY WITH EITHER OF THE FOLLOWING AND THE ACCESSIBLE PORTION OF THE COUNTER TOP SHALL EXTEND THE SAME DEPTH AS THE SALES OR SERVICE COUNTER TOP. §11B-904.4 (SEE EXCEPTION) a.A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES LONG MINIMUM AND 34 INCHES HIGH MAXIMUM ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 11B-305 SHALL BE POSITIONED FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH MINIMUM LENGTH OF COUNTER. §11B-904.4.1 (SEE EXCEPTION) OR b.A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES LONG MINIMUM AND 34 INCHES HIGH MAXIMUM SHALL BE PROVIDED. KNEE AND TOE SPACE COMPLYING WITH 11B-306 SHALL BE PROVIDED UNDER THE COUNTER. A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 11B-305 SHALL BE POSITIONED FOR A FORWARD APPROACH TO THE COUNTER. §11B-904.4.2 41.WHERE PROVIDED, AT LEAST ONE OF EACH TYPE OF SALES COUNTER AND SERVICE COUNTER SHALL COMPLY WITH 11B-904.4. WHERE COUNTERS ARE DISPERSED THROUGHOUT THE BUILDING OR FACILITY, COUNTERS COMPLYING WITH 11B-904.4 ALSO SHALL BE DISPERSED. §11B-227.3 42.QUEUES AND WAITING LINES SERVICING COUNTERS OR CHECK-OUT AISLES REQUIRED TO COMPLY WITH 11B-904.3 OR 11B-904.4 SHALL COMPLY WITH 11B-403. §11B-227.5 43.WHERE COUNTERS OR TELLER WINDOWS HAVE SECURITY GLAZING TO SEPARATE PERSONNEL FROM THE PUBLIC, A METHOD TO FACILITATE VOICE COMMUNICATION SHALL BE PROVIDED. TELEPHONE HANDSET DEVICES, IF PROVIDED, SHALL COMPLY WITH 11B-704.3. §11B-904.6 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES, AND FUEL DISPENSERS 44.EXCEPT AT DRIVE-UP ONLY DEPOSITORIES, WHERE PROVIDED, AT LEAST ONE OF EACH TYPE OF DEPOSITORY, VENDING MACHINE, CHANGE MACHINE, AND FUEL DISPENSER SHALL COMPLY WITH 11B-309. §11B-228.1 45.WHERE MAIL BOXES ARE PROVIDED IN AN INTERIOR LOCATION, AT LEAST 5 PERCENT, BUT NO LESS THAN ONE, OF EACH TYPE SHALL COMPLY WITH 11B-309. §11B-228.2 46.GAS PUMP NOZZLES SHALL NOT BE REQUIRED TO PROVIDE OPERABLE PARTS THAT HAVE AN ACTIVATING FORCE OF 5 POUNDS (22.2N) MAXIMUM. §11B-309.4 (SEE EXCEPTION) H. ASSEMBLY AREAS 1.ASSEMBLY AREAS SHALL PROVIDE WHEELCHAIR SPACES, COMPANION SEATS, DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS COMPLYING WITH 11B-221 AND 11B-802. §11B-221.1 2.LAWN SEATING AREAS AND EXTERIOR OVERFLOW SEATING AREAS, WHERE FIXED SEATS ARE NOT PROVIDED, SHALL CONNECT TO AN ACCESSIBLE ROUTE. §11B-221.5 3.PROVIDE NUMBER OF WHEELCHAIR SPACES PER TABLE §11B-221.2.1.1 4.IN EACH LUXURY BOX, CLUB BOX, AND SUITE WITHIN ARENAS, STADIUMS, AND GRANDSTANDS, WHEELCHAIR SPACES COMPLYING WITH SECTION 11B-802.1 SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 11B-221.2.1.1. §11B-221.2.1.2 5.IN OTHER BOXES, THE TOTAL NUMBER OF WHEELCHAIR SPACES REQUIRED SHALL BE DETERMINED IN ACCORDANCE WITH TABLE 11B-221.2.1.1. WHEELCHAIR SPACES SHALL BE LOCATED IN NOT LESS THAN 20 PERCENT OF ALL BOXES PROVIDED. §11B- 221.2.1.3 6.AT LEAST ONE WHEELCHAIR SPACE COMPLYING WITH SECTION 11B-802.1 SHALL BE PROVIDED IN TEAM OR PLAYER SEATING AREAS SERVING AREAS OF SPORT ACTIVITY. §11B-221.2.1.4 7.IN STADIUM-STYLE MOVIE THEATERS, THE TOTAL NUMBER OF WHEELCHAIR SPACES REQUIRED SHALL BE PER TABLE 11B- 221.2.1.1.THE REQUIRED WHEELCHAIR SPACES SHALL BE LOCATED ON RISERS OR CROSS-AISLES IN THE STADIUM SECTION THAT SATISFY AT LEAST ONE OF THE FOLLOWING CRITERIA: §11B-221.2.1.5 a.LOCATED WITHIN THE REAR 60% OF THE SEATS PROVIDED IN THE THEATER; OR b.LOCATED WITHIN THE AREA OF THE THEATER IN WHICH THE VERTICAL VIEWING ANGLES (AS MEASURED TO THE TOP OF THE SCREEN) ARE FROM THE 40TH TO THE 100TH PERCENTILE OF VERTICAL VIEWING ANGLES FOR ALL SEATS AS RANKED FROM THE SEATS IN THE FIRST ROW (1ST PERCENTILE) TO SEATS IN THE BACK ROW (100TH PERCENTILE). AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NOT U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D 3'- 0 " ( P A R K I N G ) 5" ( B U I L D I N G E N T R A N C E S I G N A G E ) 3'-0" (PARKING) 5" (BUILDING ENTRANCE SIGNAGE) SCALE:5 ACCESSIBLE SYMBOL N.T.S. HANDICAPPED BLUE COLOR, BACKGROUND #15090 FED. STD. 595C OR EQ. WHITE HIGHWAY PAINT 2 COATS, 3" WIDE TYP. F.F. 64 " 43 " 42 " 38 " DOOR & FRAME, WHERE OCCURS VIEWER ℄ OF DR. DEADLOCK OR PUSH PLATE ℄ OF DOOR PULL GRIP AND OF PUSH-PULL BAR ℄ OF LEVER HANDLE, LATCH AND CROSS BAR ON FIRE EXIT DEVICE UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT: 17" (MIN.) 24" RECOMMENDED 22 " ( M I N . ) 24 " R E C O M M E N E D E D NOTES: 1. SIGN TO BE REFLECTORIZED PORCELAIN STEEL WITH BEADED TEXT 2.BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL. 3. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS. 4. SIGN TO BE PROVIDED AT ALL ENTRY DRIVEWAYS 5. CITY OF XX POLICE DEPARTMENT OR BY CALLING: (XXX) XXX-XXXX. SIGN LETTERING SHALL BE NOT LESS THAN 1" IN HEIGHT 12" (MIN.) 12 " ( M I N . ) NOTES: 1. SIGN TO BE REFLECTORIZED PORCELAIN STEEL. 2. BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL. 3. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS. 4. ARROW SHALL POINT IN THE DIRECTION OF THE PATH OF TRAVEL PARKING ONLY MINIMUM FINE $250 VAN ACCESSIBLE NOTES: 1. SIGN TO BE REFLECTORIZED WITH AN AREA OF THE SIGN(S) IS NOT SMALLER THAN 70 SQUARE INCHES 2. SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE 3.BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFAQCE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL 4. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS 5. SIGN TO BE PROVIDED AT ALL PARKING SPACES RESERVED FOR PERSONS WITH DISABILITIES 60" MIN. 72" MIN. 72" MIN. 72" MIN. 72" MIN.60" MIN. 72" MIN. 48" DN . MIN. (REFER TO NOTE #5) 12" TW + 12" MIN.36 " 12" MIN. 12" TW + 12" MIN. TO F I N I S H F L O O R 36 " 12" MIN. 27 " M A X . 27 " M A X . 1-1/4" MAX. 30° MAX.30° MAX. 1-1/4" MAX. . 3' - 0 " NOTE: 1.SHADED AREAS OF RAMP MUST HAVE DETECTABLE WARNING SURFACE CROSS SLOPE OF LANDING 2.AREAS SHALL NOT EXCEED 2% IN ANY DIRECTION. 30" MAX. RISE (TYP.) 12" 36 " HANDRAILS MUST EXTEND A MINIMUM OF 12" OF LEVEL DISTANCE (PARALLEL TO LANDING SURFACE) BEYOND TOP AND BOTTOM OF THE RAMP ENDS THE RAMP ENDS BEFORE THEY ARE RETURNED 12" 4" MA X . 30 " 43 " 36 " 36 " 48" MIN. 48" MIN. WIDTH GUARD RAIL IN ACCORDANCE WITH CBC 1015 SCALE:17 GENERAL RAMP REQUIREMENTS N.T.S. G RAMP WITH TURNING PLATFORM A CURB RAMPS F RAMP WITH INTERMEDIATE SWITCHBACK PLATFORM E STRAIGHT RAMP RUN D HANDRAIL AT RAMPS VARIES (30' MAX.) 60" MIN. 30" MAX. RISE (TYP.) AT LEAST AS WIDE AS RAMP RUN C - C RAMP SECTION WIDTH MUST BE A MINIMUM OF 60" WHEN SERVING AN OCCUPANCY 300 OR MORE 1-1/4" TO 1-1/2" DIA. HANDRAIL AT RAMPS EDGE PROTECTION - IN FORM OF A BARRIER: 2" HIGH CURB (6" HIGH WARNING CURB WHERE A DROP OF 4" OR MORE OCCURS) < 4" AND < 30" ADJACENT HAZARD 72" MIN. 60" MIN. INTERMEDIATE PLATFORM AT LEAST AS WIDE AS RAMP RUN 30" MAX. RISE (TYP.) 60" MIN. LANDING GUIDE CURB OR WARNING CURB POST @ 4'-0" O.C. MAX SCALE:2 ACCESSIBLE PARKING STALL SIGNAGE N.T.S. SCALE:3 UNAUTHORIZED VEHICLE WARNING SIGNS N.T.S. SCALE:4 ACCESSIBLE PATH OF TRAVEL N.T.S. 1/2" RADIUS TYPICAL WHITE ON BLUE BACKGROUND WHITE ON BLUE BACKGROUND TYPICAL 1/2" RADIUS TYPICAL VAN ACCESSIBLE SIGN WHERE APPLICABLE C HANDRAIL EXTENSIONS AT STAIRWAY SCALE:9 STAIR DETAILS N.T.S. B ACCEPTABLE STAIR NOSING SOLID RISER, TYPICAL 1/2" RADIUS MAX. RADIUS NOSING BEVELED NOSING 1/2" BEVEL MAX. ROUNDED OR BEVELED NOSING, TYPICAL VISUAL WARNING STRIPS SHALL BE 2" MIN. (4" MAX.) WIDTH AND INSTALLED 1" MAX. FROM EDGE OF THE TOP AND BOTTOM TREADS OF INTERIOR STAIRS, AND ON ALL TREADS OF EXTERIOR STAIRS. BOTTOM LANDING TOP LANDING VISUAL WARNING STRIPS SHALL BE 2" MIN. (4" MAX.) WIDTH AND INSTALLED 1" MAX. FROM EDGE OF THE TOP AND BOTTOM TREADS OF INTERIOR STAIRS, AND ON ALL TREADS OF EXTERIOR STAIRS.BOTTOM LANDING TW = TREAD WIDTH TW TW = TREAD WIDTH TO F I N I S H F L O O R TOP LANDING TW 24" MIN. OF STRAIGHT CURB 1-1/2"TO 1-1/2" 1-1/4" 3" MAX. 18 " M I N . 1 1 / 2 " MI N . 2 1/4 MAX 2 1/4 M A X 1 1 / 2 M I N 1 1/2 MIN - 2 MAX 1 1/2 NON-CIRCULAR CROSS SECTION A CLEARANCE & GRIPPING SURFACES CIRCULAR CROSS SECTION 4-6 14 PERIMETER INTERMEDIATE TURNING POSITION 48" 30 " M I N . 48" Y Z NOTES: Z X 48" MIN. 48 " 15 " M I N . 48" 30 " M I N . X 48 " M I N I M U M 48 " M I N I M U M 12" MIN. 18" MIN. 1/ 4 " MA X . 48" MIN. CLR. 1/ 2 " MA X . 2 1 SCALE:26 GENERAL DOOR REQUIREMENTS N.T.S. A.FLOOR(S) OR LANDING(S) ARE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE THRESHOLD OF THE DOORWAY. B.CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" IS BEVELED AT A MAXIMUM GRADIENT OF 1:2. C.RECESSED DOOR MATS ARE ADEQUATELY ANCHORED TO PREVENT INTERFERENCE WITH OF 1:2. D.CARPET AND CARPET TILES ARE SECURELY ATTACHED AND HAVE LEVEL LOOP, TEXTURED LOOP, LEVEL-CUT PILE OR LEVEL-CUT/UNCUT PILE WITH PILE NOT EXCEEDING 1/2" IN HEIGHT. E.EXPOSED EDGES OF CARPET ARE FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. LEVER, LOOPED AND PUSH BAR DOOR HARDWARE 10" MIN. BOTTOM RAIL RUBBER BUMPER ON CHAIR 1/ 2 " PROVIDE THIS ADDITIONAL SPACE IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER 1/2" MAX. PILE HEIGHT COMPRESSED CARPET 1/4" MAX. BELOW THRESHOLD THRESHOLD FIN. FLOOR LEVEL NOTES: 1.CHANGES IN LEVEL BETWEEN 1/4" HIGH MIN. AND 1/2" HIGH MAX. SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. 2.1/4" MAXIMUM VERTICAL LEVEL CHANGE. SCALE:25 WALKS & SIDEWALKS N.T.S. SCALE:29 REACH REQUIREMENTS N.T.S. DOOR TYPE: A.REQUIRED EXIT DOORWAY(S) ARE OF A SIZE TO PERMIT INSTALLATION OF A DOOR A MINIMUM 3' IN WIDTH, 6'-8" IN HEIGHT B.EXIT DOOR IS CAPABLE OF OPENING A MINIMUM OF 90 DEGREES C.THE CLEAR WIDTH OF THE DOORWAY IS 32" MINIMUM. D.DOUBLE DOORS/AUTOMATIC DOORS - AT LEAST ONE DOOR MUST COMPLY WITH DOOR TYPE ITEM B AND C ABOVE E.BOTTOM 10" OF DOOR (EXCEPT SLIDING DOORS) HAS A SMOOTH, UNINTERRUPTED SURFACE THAT ALLOWS DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION F.EFFORT TO OPERATE DOOR IS WITHIN PRESSURE ALLOWED. INTERIOR AND EXTERIOR DOORS - 5 POUNDS MAXIMUM PRESSURE TO OPERATE. FIRE DOORS - 15 POUNDS MAXIMUM PRESSURE TO OPERATE G.TWO DOORS A SERIES PROVIDE A MINIMUM OF 48" CLEAR SPACE FROM ANY DOOR IN ANY POSITION HARDWARE: A.HANDLES, PULL LATCHES, LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE OPERATE B.LATCHING AND LOCKING DOORS THAT ARE HAND OPERATED AND WHICH ARE IN A PATH OF TRAVEL ARE OPERABLE BY LEVER TYPE, PANIC BARS, PUSH-PULL ACTIVATION BARS, U-SHAPED HANDLES OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION C.11B-404.2.7 OPENING HARDWARE IS CENTERED BETWEEN 34" AND 44" ABOVE FINISH FLOOR D.11B-404.2.8.1 - DOOR CLOSERS AND GATE CLOSERS, IF PRESENT, SHALL BE ADJUSTED SO THAT FROM AN OPENING POSITION OF 90°, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12° FROM THE LATCH IS 5 SECONDS MINIMUM 11B-404.2.8.2 - DOOR AND GATE SPRING HINGES, IF PRESENT, SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70°, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM THRESHOLD PROVIDE THIS ADDITIONAL SPACE IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER 1.X SHALL BE < 25 INCHES; Z SHALL BE EQUAL TO X. 2.WHEN X < 20 INCHES, THEN Y SHALL BE 48 INCHES MAXIMUM. 3.WHEN X IS 20 TO 25 INCHES, THEN Y SHALL BE 44 INCHES MAXIMUM. B DOOR HARDWARE & MOUNTING HEIGHTS D THRESHOLD E TRANSITION BETWEEN FLOOR FINISHES F VESTIBULES / TWO DOORS IN SERIES A TYPICAL DOOR ELEVATION HEIGHTS D MAXIMUM FORWARD REACH OVER AN OBSTRUCTION E HIGH FORWARD REACH LIMITS F CLEAR FLOOR SPACE - FRONT APPROACH B SIDEWALK OBSTRUCTIONS A LEVEL CHANGES CURB (TYP.) STREET (TYP.) SIDEWALK VAN STALL 5'-0" 18 ' - 0 " MI N . 12'-0"9'-0" STANDARD STALL SCALE:16 ELECTRIC VEHICLCLE CHARGING PARKING STALL & SIGNAGE N.T.S. EV CHARGING ONLY EV CHARGING ONLY ACCESSIBLE ROUTE CLEAR FLOOR SPACE EV CHARGER STANDARD ACCESSIBLE EVCS EVCS NOT REGULATED BY SECTION 11B-812 VAN ACCESSIBLE EVCS 80 " MI N . 27 " MA X . 4" MAX. SCALE:24 PROTRUDING OBJECTS N.T.S. ACCESSIBLE ROUTE 4' - 0 " MI N . CL R . 1' - 0 " VE H I C L E OV E R H A N G NO PARKING 12" HIGH LETTERING INDICATING "NO PARKING," PAINT 2 COATS TRAFFIC WHITE 12" HIGH LETTERING INDICATING "EV CHARGING ONLY," PAINT 2 COATS TRAFFIC WHITE 1'- 6 "EQUIPMENT SPACE EXCEPT FOR ELECTRIC VEHICLE CHARGING 1'-0" 1-1/2" RADIUS TYPICAL RED ON WHITE BACKGROUND "P" SHALL BE BLACK 1'- 6 " NOTES: 1. SIGN TO BE REFLECTORIZED PORCELAIN STEEL. 2. BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL. 3. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS. VAN ACCESSIBLEVAN ACCESSIBLE SIGN WHERE APPLICABLE ELECTRIC VEHICLE CHARGING SIGN 16B - VARIES (30' MAX.) WHEN DOOR SWINGS ONTO LANDING: 42" MIN. PLUS DOOR WIDTH VARIES (30' MAX.) WHEN DOOR SWINGS ONTO LANDING: 42" MIN. PLUS DOOR WIDTH 60" MIN. AT LEAST AS WIDE AS RAMP RUN 60" MIN.VARIES (30' MAX.) WHEN DOOR SWINGS ONTO LANDING: 42" MIN. PLUS DOOR WIDTH 60" MIN.VARIES (30' MAX.) 1/2" RADIUS TYPICAL ADJACENT HAZARD 1/ 4 " MA X . 1/ 4 " MA X . 12" MIN. 30" 48 " M A X . 15 " MI N . 34 " M A X . 30"24" MAX. 46 " M A X . 48 " 30"10" MAX. A MAXIMUM SIDE REACH OVER AN OBSTRUCTION B HIGH AND LOW SIDE REACH LIMITS C CLEAR FLOOR SPACE PARALLEL APPROACH 48 " M I N I M U M 60 " M I N I M U M 48" MINIMUM 54" PREFERRED 24" MIN. EXTERIOR 18" MIN. INTERIOR SURFACE SLOPE NOT TO EXCEED 2% 12" MINIMUM IF DOOR HAS BOTH A CLOSER AND A LATCH SURFACE SLOPE NOT TO EXCEED 2% C TYPICAL DOOR LANDING CLEARANCES B ELETCRIC VEHICLE CHARGING SIGN A ELETCRIC VEHICLE CHARGING PARKING STALL 3'-0" TYP. 2 1 1/2" MAX. 1/4" MAX. GROUT BELOW THRESHOLD LANDING RAMP LANDING 27 " M A X . 27 " M A X . 12"12" MIN.PLAN VIEW STAIR GENERAL NOTES: RISER EIGHT AND TREAD DEPT: ·RISER HEIGHT: 7" MAX AND 4" MIN. ·RECTANGULAR TREAD DEPTH: 11" MIN. DIMENSIONAL UNIFORMITY: STAIR TREADS AND RISERS SHALL BE OF UNIFORM SIZE AND SHAPE. THE TOLERANCE BETWEEN THE LARGEST AND SMALLEST RISER HEIGHT OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTH SHALL NOT EXCEED 3/8". WALKING SURFACE: EXTERIOR WALKING SURFACE OF TREADS SHALL BE SLOPED FOR DRAINAGE NOT STEEPER THAN 2% IN ANY DIRECTION. GENERAL NOTE: PROVIDE SMOOTH, NON ABRASIVE SURFACE BEHIND HANDRAILS. 2" DIA. GALV. POLE 2" DIA. GALV. POLE 2" DIA. GALV. POLE 6'-8" MIN. 6'-8" MIN. 6'-8" MIN. 2.35" .6 5 " M I N . B TRUNCATED DOMES 2. 3 5 " .0.2" TOP DIAMETER 0.45" - 0.47" MAX BOTTOM DIAMETER 0.9" - 0.92" MAX PLAN VIEW ENLARGED ELEVATION VIEW 48" DN . DN . PLTR. 60" 48 " MI N . PLTR. DN. TYP. 6'- 6 " MI N . 48" MIN. 2% S L O P E 3'- 0 "NOTE: SURFACE WILL REQUIRE 36" SECTION OF TRUNCATED DOMES IF LANDING SURFACE ADJOINS VEHICULAR TRAFFIC WAY (SEE DETAIL "B") PAINT CURB SAFETY YELLOW (2 COATS), TYP. LINE OF OBSTRUCTION OR EDGE OF WALK AREA, AS OCCURS, TYP.3' - 0 " 4'-0" LINE OF FRONT OF REQ'D PARKING SPACE 1:10 MAX. SLOPE (TYPICAL) 1:12 SLOPE MAX. TYP. LINE OF OBSTRUCTION OR EDGE OF WALK AREA AS OCCURS, TYP. MIN. WALK AREA MIN. DN.3' - 0 " 3' - 0 " DETECTABLE WARNINGS SHALL BE LOCATED SO THE EDGE NEAREST THE CURB IS 6 INCHES (152 mm) MINIMUM & 8 INCHES (203 mm) MAXIMUM FROM THE DEMARCATION LINE AT THE FACE OF THE CURB, BETWEEN THE CURB & THE GUTTER, STREET OR HIGHWAY (CBC 11B-705.1.2.2.1) VAN STALL 5'-0" 18 ' - 0 " SEE SITE PLAN FOR STALL(S) CONFIGURATION. EQUAL TYP. 3'-0" T Y P . 4' - 0 " MI N . CL R . 4'-0" MIN. BLUE PAINTED CURB AT HANDICAPPED STALL ONLY TRUNCATED DOMES EQUAL TYP. 2'- 0 " ACCESSIBLE SYMBOL 4" WIDE, PAINTED BLUE STRIPES (2 COATS) 12'-0" CAR OVERHANG LINE WHERE OCCURS, SEE SITE PLAN RA M P DO W N 12" HIGH LETTERING INDICATING "NO PARKING," PAINT 2 COATS TRAFFIC WHITE CONC. CURB - SEE SITE PLAN AND CIVIL DWG'S FOR PROFILE REQUIRED 9'-0" STANDARD STALL 4'-0" LONG CONCRETE WHEEL STOP ALIGN, TYPICAL 4'- 0 " MI N . C L R . HANDICAP PARKING SIGN36 " 4'-0" MIN. CLR. SCALE:1 ACCESSIBLE PARKING STALL N.T.S. 17B - 2 - 5 - NOTE: SLOPE OF PARKING STALL AND ADJACENT ACCESSIBLE AISLE NOT TO EXCEED 2% SLOPE IN ANY DIRECTION NO PARKING 4" WIDE, PAINTED BLUE STRIPES (2 COATS) L E S S T H A N 6 0 " W I D E 6 0 " M I N . 60" MIN. 60" MIN. 60" MIN. 60" MIN. 200' MAX 200' MAX 200' MAX 400' MAX 6 0 " M I N . 60 " M I N . 60 " M I N . PASSING SPACE (2% MAX CROSS-SLOPE) LEVEL REST AREA (2% MAX SLOPE IN ANY DIRECTION) SCALE:19 PASSING SPACES N.T.S. 48" MIN . 4 8 " M I N . LESS THAN 60" WIDE 2 % M A X 5% MAX 5% MAX LEVEL TURNING AREA (2% MAX SLOPE IN ANY DIRECTION) A RESTING AND PASSING AREAS NOTES: AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES PROVIDES PASSING SPACES AT INTERVALS OF 200 FEET MAXIMUM. THE PASSING SPACES ARE EITHER A SPACE 60 INCHES MINIMUM BY 60 INCHES MINIMUM, OR AN INTERSECTION OF TWO WALKING SURFACES THAT PROVIDE A COMPLIANT T-SHAPE TURNING SPACE WHERE THE BASE AND ARMS OF THE T-SHAPE SPACE EXTEND 48 INCHES MINIMUM BEYOND THE INTERSECTION. 11B-403.5.3 1:10 MAX. SLOPE (TYPICAL) 1:12 SLOPE MAX. TYP. 1:12 SLOPE MAX. TYP. NOTES: 1.DETECTABLE WARNING SURFACE SHALL BE YELLOW CONFORMING TO FS 33538 OF FEDERAL STANDARD 595C 2.MATERIAL USED SHALL BE RECESSED INTO WALKING SURFACE 3.DETECTABLE WARNING SURFACE SHALL CONTRAST VISUALLY WITH ADJACENT WALKING SURFACES EITHER LIGHT-ON-DARK OR DARK-ON-LIGHT 4.ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 24, PART 1, CHAPTER 5, ARTICLE 2, 3 AND 4 6" UPDATE TOWING INFORATION G403 ACCESSIBILITY DETAILS NO T U S E D AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NOT U S E D NOT U S E D STRUCTURAL STRENGTH: ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHERE A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS (1112 N) IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER MOUNTING DEVICE, OR SUPPORTING STRUCTURE. 33 " - 3 6 " T. O . G R A B B A R 48 " T. O . S H O W E R H E A D C O N T R O L H A N D L E 17 " M I N . 19 " M A X 30 " M I N . 60" MIN. 15" to 16" 6" MAX 24" MIN. 6" 24 " M I N . 17 " M A X . SEE PLAN 17 " M A X . 13-1/2" MIN. T&H EQEQ 44 " M A X . H A N D O P E R A T E D FL U S H C O N T R O L S T&H 18" MIN.18" MIN. > 2 4 " < 2 4 " 19 " MA X . 32" MIN. CLR. FLUSH HANDLE OR VALVE SHALL BE ON WIDE SIDE 60" C L E A R F L O O R S P A C E 60" CLR. MIN. 34 " M I N . CL E A R 4" M A X 35"-37" 60 " M I N . 44 ' M I N . 60" CLR. MIN. 17" MIN. 34 " M A X . 29 " M I N . 6" MAX. TOE CLEARANCE 8" 9" MI N . 24" MIN. 48" 7"-9" 48" MIN. CLR. TO ADJ. WALL 33 " - 3 6 " T. O G R I P P I N G S U R F A C E 40 " M A X . 54" MIN 42" MIN. ℄. 60 " M I N . M A N E U V E R I N G S P A C E 36 " M I N . WH E N D O O R S W I N G S I N 16 G404 E FG 48 " M I N . 17"- 19" 8" 27 " M I N . MIN. KNEE CLEARANCE 60" C L E A R F L O O R S P A C E 59 " M I N . @ F L O O R M O U N T E D W A T E R C L O S E T SURFACE MOUNTED SANITARY NAPKIN DISPOSAL WHERE OCCURS SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER PROVIDE BACKING 60" CLR. MIN. 32" MIN. CLR. 4" MAX. FLUSH VALVE OR VALVE SHALL BE ON 'WIDE SIDE" SURFACE MOUNTED SANITARY NAPKIN DISPOSAL WHERE OCCURS SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER SURFACE MOUNTED TOILET SEAT-COVER DISPENSER 30"x48" CLR. FLOOR SPACE SELF-CLOSING DOOR SELF-CLOSING DOOR 6" CLEAR G ELEVATIONFELEVATION B SIDE OPENING DOORASINGLE ACCOMODATION C SIDE FRONT DOOR D AMBULATORY SCALE:16 ACCESSIBLE TOILET PLAN & ELEVATIONS 1/2"=1'-0" SCALE:19 ACCESSIBLE URINAL PLAN & ELEVATIONS 1/2"=1'-0" C ELEVATION B PLANDELEVATION A PLAN (ALCOVE) SCALE:20 ACCESSIBLE SHOWER PLAN & ELEVATIONS 1/2"=1'-0" C ELEVATION B ELEVATION A PLAN 30"x48" CLEAR 36"x48" CLEAR STRUCTURAL STRENGTH: ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHERE A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS (1112 N) IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER MOUNTING DEVICE, OR SUPPORTING STRUCTURE.36"x60" CLEAR 17"-18"17"-18"17"-18"18" 19 " M I N . TO O P E N ' G 19 " M I N . TO O P E N ' G 11" MIN. SINK 34 " M A X . 6- 1 / 2 " M A X . SI N K D E P T H 27 " M I N . K N E E CL E A R A N C E 19" DEPTH KNEE CLEARANCE 24" MAX. 3'-0" CLEAR 18" MIN. ATTACH TOE KICK TO CABINET DOOR UPPER CABINETS WHERE OCCURS 30" MIN 19 " M A X 8"MIN 11"MIN 9" M I N B SECTION A PLAN SCALE:22 ACCESSIBLE SINK PLAN & SECTION SCALE: 1/2"=1'-0" B - ℄ B-2888 TOILET TISSUE DISPENSER MULTI-ROLL TOILET TISSUE DISPENSER BOBRICK SATIN FINISHED B-221 TOILET SEAT COVER DISPENSER CLASSIC SERIES SURFACE MOUNTED SEAT-COVERED DISPENSER BOBRICK SATIN FINISHED B-5806 SERIES 42" GRAB BARS BOBRICK SATIN FINISHED B-5806 SERIES 48" GRAB BARS 1 1/4"Ø STAINLESS STEEL BOBRICK SATIN FINISHED B-270 SANITARY NAPKING DISPOSAL RECEPTACLE BOBRICK SATIN FINISHED 1 2 3 4 5 CODEITEM NO.MANUF.COLORNAMEDESCRIPTION H ACCESSORIES SPECIFICATIONS 18" MIN. CLR. 59 " M I N . @ F L R M O U N T E D W A T E R C L O S E T 56 " M I N . @ W A L L M O U N T E D W A T E R C L O S E T 48 " M I N . M A N E U V E R I N G S P A C E 12" MAX. 40 " M A X . T O R E F L E C T I V E SU R F A C E 2 12" MAX. 1 12" MA X . 27" MAX. 48 " M A X . T. O . S H O W E R C O N T R O L S A. ACCESSIBLE BENCH PLAN NOTE: ·CLEAR FLOOR OR GROUND SPACE SHALL BE PROVIDED AND POSITIONED AT THE END OF THE BENCH SEAT AND PARALLEL TO THE SHORT AXIS OF THE BENCH ·BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL ALONG ITS LONG DIMENSION ·BENCH SHALL BE AFFIXED TO THE WALL OR FLOOR ·ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A FORCE OF 250 POUNDS IS APPLIED 30"x48" WHEELCHAIR ACCESS AT EITHER END OF ACCESSIBLE BENCH B. ACCESSIBLE BENCH SECTION 48" MIN. 2 1 / 2 " MA X . 20 " M I N . 24 " M A X . 17 " M I N . 19 " M A X . 18 " M I N . 2" MA X . C. ACCESSIBLE LOCKER SECTION 40 " M I N . 4 8 " M A X . H E I G H T 15 " L O W E S T RE A C H R A N G E SHELF SCALE:8 ACCESSIBLE BENCH AND LOCKER DETAIL SCALE: 1/2"=1'-0" 39 " M I N . - 4 1 " M A X 18 " M I N . 39" MIN. - 41" MAX. VERTICAL GRAB BAR WHERE OCCURS. ℄. B-2111 SERIES SOAP DISPENSER SURFACE MOUNTED SOAP DISPENSER BOBRICK SATIN FINISHED6 B-2620 SERIES PAPER DISPENSER SURFACE MOUNTED PAPER DISPENSER BOBRICK SATIN FINISHED7 25" MAX. 18" MIN. 34 " M A X . 40 " M A X . W H E N M O U N T E D OV E R C O U N T E R O R L A V . 33 " - 3 6 " T. O . G R I P P I N G OF S U R F A C E 6" MAX.42" 12" MIN. 17"-18"PLUMBEREX, PRO-EXTREME SERIES X4333 KIT INCLUDES: P-TRAP COVER, TWO (2) SUPPLY COVERS FIN. FACE OF WALL 36" MIN. 1- 1 / 2 " MI N . K-4368HIGHCLIFFC_TOILETSVITREOUS CHINA E ELEVATION 40 " M A X . W H E N M O U N T E D OV E R C O U N T E R O R L A V . SURFACE MOUNTED PAPER DISPENSER 71 5 43 2 2 6 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL RECEPTACLE 1 1/4"Ø STAINLESS STEEL LEVER HANDLE FOR FAUCET - SEE PLUMBING DWGS NOTE: INSULATE DRAIN & HOT WATER PIPES 17 " - 1 9 " SE A T S 2" M A X COUNTER F.F. 44 " 4" 8" 15 " MI N . 48 " M A X . 48 " M A X . DO O R H E I G H T M I N U S 8 " 80 " ( O R 6 " B E L O W CE I L I N G W H I C H E V E R I S L O W E R ) 48 " M A X . 48 " M A X 48 " M A X . TO P O F H A N D L E CARD READER, LOCAL ALARM, ARMING OR INTERCOM STATION, WALL PHONE OUTLET ELECTRICAL OR COMMUNICATION OUTLET ABOVE COUNTER A B ELECTRICAL OR COMMUNICATION OUTLET C LIGHT SWITCH D THERMOSTAT E ELECTRO MAGNETIC DOOR HOLD-OPEN F AUDIBLE & VISUAL FIRE ALARM OR SECURITY STROBE LIGHT G MANUAL FIRE ALARM PULL STATION H FIRE EXTINGUISHER I FIRE EXTINGUISHER IN CABINET SCALE:9 MOUNTING HEIGHTS FOR RESTROOM ACCESSORIES 3/8"=1'-0" SCALE:10 MOUNTING HEIGHTS 3/8"=1'-0" SCALE:26 EXIT & RESTROOM SIGNAGE 3/8"=1'-0" BACK SPLASH 6" F.F.48 " M I N . T O B A S E L I N E O F T H E LO W E S T B R A I L L E C E L L S 60 " M A X . EXIT ROUTE EXIT EXIT 12 " 3" EQ.EQ. AL I G N W I T H T O P O F A D J . F R A M E 12 " O R GR E A T E R WALL MOUNTED EXIT SIGN AT EXIT DOOR MO U N T O N S T R I K E S I D E W H E N D I M A B O V E DO O R H E A D < 1 2 " 18"MIN. CLEAR ℄ EQ.EQ. WALL OR OBSTRUCTION WHERE OCCURS 40 " M A X . T O H I G H E S T OP E R A B L E P A R T ACCESSIBLE TOWEL DISPENSER ACCESSIBLE SANITARY NAPKIN/TAMPON VENDOR ACCESSIBLE SOAP DISPENSER ACCESSIBLE SEAT COVER DISPENSER 33 " - 3 6 " T. O . G R I P P I N G OF S U R F A C E GRAB BARSSPACING AROUND GRAB BARS 19 " M I N . ACCESSIBLE ROLL TOILET TISSUE DISPENSER ACCESSIBLE SANITARY NAPKIN DISPOSAL A B C D E G H I 1 1 / 2 " M I N . 12 " MI N . 4" MAX. POINT OF DISPENSING 40 " M A X . B . O . RE F L E C T I V E SU R F A C E O V E R A CO U N T E R O R L A V . 35 " M A X . A N Y W H E R E EL S E MIRROR MOUNTING HEIGHTS J SURFACE-MOUNTED DRYER F 34 " M A X 19 " M A X 45° CENTERED ON TACTILE CHARACTERS 18 " M I N . CL E A R 18"MIN. CLEAR ℄ EQ. 60 " M A X . B A S E L I N E O F H I G H E S T LE V E L O F R A I S E D C H A R A C T E R S ℄ 48 " M I N . T O B A S E L I N E O F T H E LO W E S T B R A I L L E C E L L S EQ EQ 60 " M A X . 58 " - 6 0 " CE N T E R R E S T R O O M S I G N WI T H I N 1 8 " O F D O O R F R A M E ℄ EQ. ℄ ALL GENDERRESTROOMALL GENDERRESTROOM WALL OR OBSTRUCTION WHERE OCCURS 18"MIN. CLEAR B SIGNAGE LOCATION AT TOILET ROOM DOOR A EXIT, EXIT ROUTE, EXIT STAIRS & ROOM SIGNAGE C TYPICAL LOCATION OF TACTILE SIGNS AT DOORS ELECTRICAL RECEPTACLE, SWITCH & CONTROLS FIRE CONTROL DEVICES PROTRUDING OBJECT ABOVE GRAB BARS MEN WOMEN ALL GENDER 6" MIN . 3 WOMEN'S ACCESSIBLE TOILET SIGNAGE 2 MEN'S ACCESSIBLE TOILET SIGNAGE 1 UNISEX / ALL GENDER ACCESSIBLE TOILET SIGNAGE 12 " 6" MI N . 12 " 6" MI N . 12 " THE TRIANGLE SHALL CONTRAST WITH THE CIRCLE AND THE CIRCLE SHALL CONTRAST WITH THE DOOR. THE TRIANGLE SHALL CONTRAST WITH THE DOOR. THE CIRCLE SHALL CONTRAST WITH THE DOOR. 48 " M A X . NOTE: ILLUSTRATIONS SHOWN HERE ARE FOR DIMENSIONAL ACCESSIBILITY PURPOSES ONLY. A SECOND DRINKING FOUNTAIN SHOULD BE PROVIDED AT A MOUNTING HEIGHT SUITABLE TO PERSONS WITH LIMITED PHYSICAL BENDING ABILITY, ADJACENT TO THE ACCESSIBLE FOUNTAIN, MAINTAINING MINIMUM CLEARANCES NOTED AND AS REQUIRED. PROVIDE TEXTURED AREA OF CONTRASTING COLOR TO IDENTIFY WATER FOUNTAIN LOCATION. WHEN FOUNTAIN IS AT AN INTERIOR LOCATION, THE TEXTURED AREA SHALL ALSO BE OF DIFFERENT RESILIENCY THAN THAT OF THE ADJACENT FLOOR SURFACE FINISH. 27 " M I N . 36 " M A X . 32" CLEAR FOR SINGL E 18" MIN . 19" MAX . 18" MIN . 24" MAX . 6" MIN. 6" MAX. SCALE:18 HI-LO DRINKING FOUNTAIN N.T.S. Hi-LO FOUNTAIN DESIGN 38 " M I N . T O 4 3 " M A X . 5" MAX. 11B-602 DRINKING FOUNTAINS: SHALL COMPLY WITH SECTION 11B-307 AND 11B-602. 11B-602.2: CLEAR FLOOR SPACE: UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 POSITIONED FOR A FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 SHALL BE PROVIDED. 11B-602.3 OPERABLE PARTS: SHALL COMPLY WITH SECTION 11B-309. THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE MOUNTED AND LOCATED WITHIN 6 INCHES OF THE FRONT EDGE OF THE FOUNTAIN OR AUTOMATIC ELECTRONICALLY CONTROLLED DEVICE. 11B-602.4 SPOUT HEIGHT: SPOUT OUTLETS SHALL BE 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. 11B-602.5 SPOUT LOCATION: THE SPOUT SHALL BE LOCATED 15 INCHES MAXIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES MAXIMUM FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. 11B-602.6 WATER FLOW: WATER FLOW SHALL COMPLY WITH SECTION 11B-602.6 11B-602.7 DRINKING FOUNTAINS FOR STANDING PERSONS: SPOUT OUTLETS OF THE DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM ABOVE FINISH OR GROUND. 11B-602.8 DEPTH: WALL- AND POST-MOUNTED CANTILEVER DRINKING FOUNTAINS SHALL BE 18 INCHES MINIMUM AND 19 INCHES MAXIMUM IN DEPTH. 11B-602.9 PEDESTRIAN PROTECTION: ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED IN COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN WHICH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32 INCHES WIDE MINIMUM, AND 18 INCHES DEEP MINIMUM, AND SHALL COMPLY WITH SECTION 11B-305.7. WHEN USED, WING WALLS OR BARRIERS SHALL PROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES VERTICALLY FROM THE FLOOR OR GROUND SURFACE. 60 " M A X . T O B A S E L I N E O F R A I S E D C H A R A C T E R S 1 THRU 2 NO ROOF ACCESS STAIR 1 160 " M A X 1ST FLOOR SIGN 1 60 " M A X FIN. FLR. 4" 4" 1 THRU 2 NO ROOF ACCESS STAIR 1 2 2ND FLOOR SIGN 1ST LEVEL 48 " M I N BRAILLE EACH ELEVATOR HOISTWAY ENTRANCE MUST HAVE RAISED FLOOR DESIGNATION CHARACTERS, SANS SERIF OR SIMPLE SERIF TYPE, 2" HIGH ON EACH DOOR JAMB CENTERED 60" AFF, AND THE SIGNS FOR THE MAIN ENTRY FLOOR MUST INCLUDE A RAISED STAR. THE CHARACTERS MUST BE WHITE ON A BLACK BACKGROUND. BRAILLE MUST BE PLACED BELOW THE CORRESPONDING RAISED CHARACTERS ADD RAISED STAR TO FLOOR IDENTIFICATION SIGNS, REQUIRED ON FIRST FLOOR SIGN ONLY 2ND LEVEL ADD RAISED STAR TO FLOOR IDENTIFICATION SIGNS, REQUIRED ON FIRST FLOOR SIGN ONLY 48 " M I N . T O B A S E L I N E O F TA C T I L E C H A R A C T E R S EXIT 6" 6" EQ . EQ . 1/8" THICK MATTE ACRYLIC SIGN COLOR TO BE VERIFIED ADA COMPLIANT GRADE 2 BRAILLE BEADS SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT SEPARATED 3/8 INCH MIN. 1/2 INCH MAX. FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH FROM RAISED BORDERS AND DECORATIVE ELEMENTS ADA COMPLIANT WHITE LETTERS. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASE LINE OF THE CHARACTER SHALL BE 5/8 INCH MIN. AND 2 INCH MAX. BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS SHALL BE 15 PERCENT MAXIMUM OF THE SAME LETTER "I" FIN. FLR. EXIT ROUTE 6" 6" EQ . EQ . LOCATE AT GRADE LEVEL EXTERIOR EXIT DOOR 1/8" THICK MATTE ACRYLIC SIGN COLOR TO BE VERIFIED ADA COMPLIANT GRADE 2 BRAILLE BEADS SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT SEPARATED 3/8 INCH MIN. 1/2 INCH MAX. FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH FROM RAISED BORDERS AND DECORATIVE ELEMENTS. REFERENCE: CBC 11B-703. DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS 0.300 INCHES MIN. AND MAX., PER TABLE 11B-703.3.1 DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS 0.300 INCHES MIN. AND MAX., PER TABLE 11B-703.3.1 BRAILLE BRAILLE FIN. FLR. BRAILLE BRAILLE 2 ADA COMPLIANT WHITE LETTERS. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASE LINE OF THE CHARACTER SHALL BE 5 8" MIN AND 2 INCH MAX BASED ON THE HEIGHT OF THE UPPER CASE LETTER "I". STROKE THICKNESS SHALL BE 15 PERCENT MAXIMUM OF THE SAME LETTER "I". FIN. FLR. SCALE:24 STAIR LEVEL IDENTIFICATION SIGNS NONE SCALE:28 TACTILE SIGN REQUIREMENTS NONE 60 " M A X 48 " M I N FIN. FLR. 60 " M A X . T O B A S E L I N E O F R A I S E D C H A R A C T E R S 48 " M I N . T O B A S E L I N E O F TA C T I L E C H A R A C T E R S A FLOOR IDENTIFICATION SIGNS B EXIT SIGNS C EXIT ROUTE SIGNS A GROUND FLOOR B UPPER OR LOWER FLOORS FIN. FLR. 6" 6" EQ . EQ . 1/8" THICK MATTE ACRYLIC SIGN COLOR TO BE VERIFIED ADA COMPLIANT GRADE 2 BRAILLE BEADS SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT SEPARATED 3/8 INCH MIN. 1/2 INCH MAX. FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH FROM RAISED BORDERS AND DECORATIVE ELEMENTS. DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS 0.300 INCHES MIN. AND MAX., PER TABLE 11B-703.3.1 BRAILLE ADA COMPLIANT WHITE LETTERS. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASE LINE OF THE CHARACTER SHALL BE 58" MIN AND 2 INCH MAX BASED ON THE HEIGHT OF THE UPPER CASE LETTER "I". STROKE THICKNESS SHALL BE 15 PERCENT MAXIMUM OF THE SAME LETTER "I". 60 " M A X . T O B A S E L I N E O F R A I S E D C H A R A C T E R S 48 " M I N . T O B A S E L I N E O F TA C T I L E C H A R A C T E R S D EXIT STAIRS SIGNS EXIT STAIRS DOWN NOTE: AUTOMATIC DOOR REOPENING DEVICE IS ACTIVATED IF AN OBJECT PASSES THROUGH EITHER LINE A OR LINE B. LINE A AND LINE B REPRESENT THE VERTICAL LOCATIONS OF THE DOOR REOPENING DEVICE NOT REQUIRING CONTACT. FLOOR LANDING NUMBERS ON BOTH SIDES OF DOOR JAMB 35 " M I N . A. F . F . 1/ 2 " M I N . 1 3 2 4 3/4" MIN. 5 6 48 " A . F . F . M A X F O R F R O N T AP P R O A C H 5 4 " A . F . F . M A X FO R P A R A L L E L A P P R O A C H NUMERAL HEIGHT MAIN ENTRY FLOOR DOOR CLOSE DOOR OPEN EMERGENCY ALARM EMERGENCY STOP HALL LANTERN CALL BUTTON ℄ B A 6' - 0 " M I N . 42 " ℄29 "60 " 5" ℄ 12 " 14" MAXIMUM OCCUPANCY 76 1/8" THICK MATTE ACRYLIC SIGN COLOR TO BE BEIGE STANDARD BLACK LETTER GRAPHICS SCALE:27 ELEVATOR CONTROL PANEL 1 1/2"=1'-0" SCALE:23 MAXIMUM OCCUPANCY SIGN NTS BUTTON WIDTH 6' - 0 " M I N . NOTE: 1) MOUNT SIGN IN A VISIBLE LOCATION BETWEEN 48" & 60" ABOVE FINISH FLOOR 2) VERIFY MAX OCCUPANCY WITH ARCHITECT NO T U S E D G404 ACCESSIBILITY DETAILS AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NOT U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NO T U S E D NOT U S E D NO T U S E D NOT U S E D NO T U S E D NO T U S E D NO T U S E D R&R JUNIORS / KIDS FASHION FORWARD FOOD SERVICE / ENTERTAINMENT PROJECT LOCATION (SUITE FC2) RESTROOMS SERVING SUITE FC2 (DISTANCE 80'-0") MALL ENTRY MALL ENTRY MALL ENTRY MALL ENTRY SCALE:26 SITE PLAN 1/48" = 1'-0" AS101 SITE PLAN NORTH LEGEND EXISTING ACCESSIBLE PATH OF TRAVEL (44" MINIMUM) NOTE: NO ABRUPT CHANGES IN ELEVATION ALONG THE PATH OF TRAVEL SHOWN. THE SLOPE & CROSS-SLOPE ALONG THE PATH OF TRAVEL SHALL NOT EXCEED 5% & 2% RESPECTIVELY (INSPECTOR TO VERIFY) AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK 12.36 6.08 WH T +84" +84" +36" +84"+84"+84" +48" +84" +80" +84" +40" +40" +48" +80" +80" +36" +90"SERVICE COUNTER KITCHEN KITCHEN SUPPORT J J GFCI GFCI GFCI GFCI GFCI GFCI GFCI 6.09 11.40 11.40 11.40 11.40 11.80 22.18 22.19B 22.19 22.19B 22.41 22.42 22.43 22.44 50.1150.11 12.36 50.12 22.19 22.19 21.09 11.80 S S S GYP. BD. +14'-9" GYP. BD. +11'-9" GYP. BD. +12'-7" 9.29 9.29 11.40 11.40 11.40 11.40 50.1150.11 9.21 9.29B 24" MAX. 3" MAX. TYP. NOTES: 1) REBAR CAN BE INSTALLED AT AN ANGLE & BENT ONCE IN FIELD 2) REPAIR VAPOR BARRIER (WHERE OCCURS) 3) REPAIR SUB-BASE (REPLACE LOST MATERIAL) (2) #4 CONTINUOUS (N) MIN 3000 PSI CONCRETE (E) SLAB ON GRADE COMPACT SOIL UNDER (N) SLAB TRENCH AS REQ'D. FOR PLUMBING DRILL & EPOXY #4 DOWELS @ 18" O.C. W/ HILTI RE-500 V3 (ESR-3814) W/ 4" EMBED ROUGHEN (E) SLAB TO 1/4" AMPLITUDE MIN. SCALE:5 SLAB INFILL DETAIL 1 1/2"=1'-0" 1" M I N . AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK A001 DEMOLITION FLOOR PLAN & REFLECTED CEILING PLAN SCALE:16 DEMOLITION FLOOR PLAN 1/2" = 1'-0" DEMOLITION LEGEND NORTH DEMOLITION KEY NOTES 22.42 HAND SINK TO BE REPLACED (SEE PROPOSED PLAN FOR LOCATION) PATCH & REPAIR WALL FINISHES TO MATCH EXISTING SCALE:26 DEMOLITION REFLECTED CEILING PLAN 1/2" = 1'-0" NORTH SCALE: 1/2"=1'-0" 0'2'1'4' SCALE: 1/2"=1'-0" 0'2'1'4' 1.PLAN LEGEND SEE SHEET G201. 2.PREPARATION: a.CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID TO FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS. b.PRE-CONSTRUCTION MEETING: CONTRACTOR SHALL CONDUCT A PRE-DEMOLITION CONFERENCE WITH OWNER, ARCHITECT AND TRADES ON SITE TO REVIEW SCHEDULE, SCOPE OF DEMOLITION WORK, CONDITION OF CONSTRUCTION TO BE DEMOLISHED AND AREAS OF EXISTING CONSTRUCTION TO REMAIN AND REQUIRED PROTECTION. c.ALL OWNER FURNITURE AND EQUIPMENT SHALL BE REMOVED AS REQUIRED. COORDINATE WITH OWNER'S PROJECT REPRESENTATIVE. 3.FIELD CONDITIONS: a OWNER DOES NOT GUARANTEE THAT EXISTING CONDITIONS ARE THE SAME AS THOSE INDICATED ON THE RECORD DOCUMENTS. b.NOTIFY THE ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS BEFORE PROCEEDING WITH DEMOLITION WORK. c.IF SUSPECTED HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY THE OWNER. d.MAINTAIN EXISTING UTILITIES TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING DEMOLITION OPERATIONS. e.MAINTAIN FIRE-PROTECTION FACILITIES IN SERVICE DURING DEMOLITION OPERATION. f.DO NOT DISRUPT ADJOINING TENANTS' OPERATION. 4.GENERAL: a.DEMOLISH AND REMOVE EXISTING CONSTRUCTION TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. b.USE METHODS REQUIRED COMPLETING THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS. c.PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE PROTECTED STORAGE LOCATION, CLEANED AND REINSTALLED AFTER DEMOLITION IS COMPLETE. d.LOCATIONS OF EXISTING POWER, TELECOM, DATA, ETC SHALL BE VERIFIED IN FIELD AFTER ALL FURNITURE, FIXTURES AND EQUIPMENT HAVE BEEN REMOVED. e.DEMOLISH ALL FLOOR, WALL AND CEILING FINISHES WHERE NEW FINISHES ARE SCHEDULED TO BE INSTALLED. SEE PROPOSED IMPROVEMENT PLANS. PATCH AND REPAIR OR PROVIDE NEW SUBSTRATE AS REQUIRED TO ACCOMMODATE NEW FINISHES. f.MAINTAIN FIRE RATING AT ALL RATED FLOOR/CEILING, ROOF/CEILING AND WALL ASSEMBLIES. g.REFER TO PLUMBING DRAWINGS FOR PLUMBING DEMOLITION WORK (WHERE APPLICABLE). h.REFER TO MECHANICAL DRAWINGS FOR ALL MECHANICAL DEMOLITION WORK (WHERE APPLICABLE). i.REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL DEMOLITION WORK (WHERE APPLICABLE). j.EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE RECYCLED, REUSED, SALVAGED, REINSTALLED, OR INDICATED TO REMAIN IN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM THE PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN APPROVED MANNER. k.CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT AND DEBRIS CAUSED BY SELECTIVE DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO EXISTING CONDITION BEFORE DEMOLITION OPERATIONS BEGAN. DEMOLITION GENERAL NOTES EXISTING WALL TO REMAIN (E) WALL TO BE REMOVED FIRE SPRINKLER (RE-CONFIGURE AS REQUIRED TO ACCOMMODATE NEW WORK) (E) MECHANICAL REGISTER TO BE REMOVED (E) LIGHT FIXTURE TO BE REMOVED (E) SUSPENDED ACOUSTICAL CEILING SYSTEM TO BE REMOVED (E) SUSPENDED ACOUSTICAL CEILING GRID TO REMAIN (E) MECHANICAL REGISTER TO REMAIN (E) LIGHT FIXTURE TO REMAIN (E) ILLUMINATED EXIT SIGN TO REMAIN (E) CEILING ACCESS PANEL TO REMAIN EXISTING TO REMAIN TO BE REMOVED FIRE SPRINKLER (RE-CONFIGURE AS REQUIRED TO ACCOMMODATE NEW WORK) S (E) SMOKE DETECTOR TO REMAIN (E) GYP. BD. CEILING / SOFFIT TO BE REMOVED (E) GYP. BD. CEILING / SOFFIT TO REMAIN (E) ELECTRICAL OUTLETS TO BE REMOVED PREP SINK TO BE REPLACED (SEE PROPOSED PLAN FOR LOCATION) PATCH & REPAIR WALL FINISHES TO MATCH EXISTING COUNTER TO BE REMOVED (PATCH & REPAIR WALL FINISHES TO MATCH EXISTING) HOUSEKEEPING PAD TO BE REMOVED - PATCH & REPAIR SLAB AS REQUIRED (SEE DETAIL 5/-) INSTALL QUARRY TILE FLOORING TO MATCH EXISTING FLUSH WITH EXISTING QUARRY TILE WALL HUNG CABINET TO BE REMOVED THREE COMPARTMENT SINK & FAUCET TO BE REPLACED (SEE PROPOSED PLAN FOR LOCATION) PATCH & REPAIR WALL FINISHES TO MATCH EXISTING MOP SINK & FAUCET TO BE REPLACED PATCH & REPAIR WALL & FLOOR FINISHES TO MATCH EXISTING FLOOR SINK TO REMAIN MENU BOARD SURROUND TO BE REMOVED KITCHEN EQUIPMENT & DUCTWORK TO BE REMOVED (TERMINATE ABOVE CEILING) PATCH & REPAIR WALL, FLOOR & CEILING FINISHES TO MATCH EXISTING PROVIDE OPENING IN EXISTING GYP. BD. CEILING TO ACCOMMODATE NEW MECHANICAL REGISTER (SEE MECHANICAL DRAWINGS) - PATCH & REPAIR & PAINT CEILING 22.43 12.36 11.80 6.08 22.41 22.44 22.19 FLOOR DRAIN TO REMAIN22.18 6.09 11.40 9.29B INTERIOR PARTITION TO BE REMOVED - PATCH & REPAIR SLAB AS REQUIRED (SEE DETAIL 5/-) PATCH & REPAIR FLOOR & WALL FINISHES TO MATCH EXISTING50.11 LOW WALL (BELOW COUNTER) TO BE REMOVED (PATCH & REPAIR FLOOR FINISHES TO MATCH EXISTING)50.12 REMOVE ANSUL CONTROL BUTTONS (PATCH & REPAIR WALL FINISHES TO MATCH EXISTING)21.09 REMOVE FLOOR SINK (CAP PIPE & FILL HOLE WITH CONCRETE FLUSH WITH EXISTING SLAB) INSTALL QUARRY FLOOR TILE TO MATCH EXISTING AT REMOVED FLOOR SINK22.19B MODIFY EXISTING SUSPENDED GYP. BD. CEILING TILE TO ACCOMMODATE NEW MECHANICAL REGISTER (SEE MECHANICAL DRAWINGS)9.21 GYP. BD. SOFFIT TO BE REMOVED (TERMINATE HVAC DUCT ABOVE NEW CEILING)9.29 T SERVICE COUNTER KITCHEN KITCHEN SUPPORT FE J J GFCI GFCI GFCI GFCI GFCI GFCI GFCI FE 6'- 8 " CE N T E R L I N E O F S I N K 3'- 6 " CE N T E R L I N E O F S I N K 2'- 8 " 1' - 7 " CE N T E R L I N E OF E Q U I P M E N T 2' - 4 " CE N T E R L I N E OF E Q U I P M E N T 2'- 2 " CE N T E R L I N E OF E Q U I P M E N T 11'-1" MILLWORK (VERIFY DIMENSIONS IN FIELD WITH S.S. TABLE BEHIND)4" 1'- 1 0 " CE N T E R L I N E OF E Q U I P M E N T 5'- 2 " CE N T E R L I N E O F E Q U I P M E N T 22.42 2'- 0 " MI L L W O R K 11.40 11.40 11.40 11.40 11.40 11.40 22.41 22.43 22.44 11.406.22 5.72 11.40 11.40 11.40 11.40 11.40 11.40 11.40 11.40 11.40 4' - 1 " CE N T E R L I N E O F E Q U I P M E N T 3' - 8 " CL E A R 17'-10" MILLWORK 1 1A 12 3 3 4 5 6 7 9 10 11 2 13 14 15 16 17 18 19 20 21 22 2'-0" MIN. CLEAR 4'-5" MILLWORK 13'-10" PREFABRICATED SERVICE COUNTER 3' - 4 " SE R V I C E C O U N T E R 23.38 23 24 25 26 27 2727 27 8.05 S S S GYP. BD. +14'-9" GYP. BD. +11'-9" GYP. BD. +12'-7" 9.29 ALIGN 9.29 6'-0" INSIDE FACE OF SOFFIT (COORDINATE WITH HOOD) 5' - 1 " CE N T E R L I N E O F F L U E 9'- 6 " CE N T E R L I N E O F F L U E 11 1/2" 11 1/2" 23.38 28 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK A101 SCALE:16 PROPOSED FLOOR PLAN 1/2" = 1'-0" FLOOR PLAN GENERAL NOTES 1.CONTRACTOR SHALL VERIFY THAT ALL EXISTING DOOR FORCES (OPENING & CLOSING) MEET THE CURRENT BUILDING CODE REQUIREMENTS 2.ALL DOORS SHALL BE SELF CLOSING NORTH PROPOSED KEY NOTES SCALE:26 PROPOSED REFLECTED CEILING PLAN 1/2" = 1'-0" NORTH SCALE: 1/2"=1'-0" 0'2'1'4' SCALE: 1/2"=1'-0" 0'2'1'4' PROPOSED FLOOR PLAN & REFLECTED CEILING PLAN #DESCRIPTION DETAIL 1.FOR PLAN SYMBOL LEGEND AND ADDITIONAL NOTES & ABBREVIATIONS SEE SHEET G201. 2.PROVIDE SEISMIC BRACING, AS REQUIRED BY CODE AND INDICATED ON DRAWINGS, FOR ALL CEILING FINISHES, PLUMBING, FIRE SPRINKLER, MECHANICAL AND ELECTRICAL SYSTEMS. 3.EXIT SIGNS, WHERE NOTED, SHALL BE WORDED "EXIT" IN LETTERS SIX INCHES (6") HIGH. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES AND PROVIDED WITH AN EMERGENCY ELECTRICAL SYSTEM FROM STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON-SITE GENERATOR SET TO INSURE CONTINUED ILLUMINATION FOR AT LEAST 90 MINUTES IN CASE OF PRIMARY POWER LOSS. 4.INTERNALLY ILLUMINATED EXIT SIGNS - ELECTRICALLY POWERED, SELF-LUMINOUS AND PHOTOLUMINESCENT EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND (CBC) CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. 5.ADDITIONAL DIRECTIONAL EXIT SIGNAGE MAY BE REQUIRED BY THE GOVERNING AGENCY HAVING JURISDICTION OVER THE PROJECT AT THE TIME OF FINAL INSPECTION. RCP GENERAL NOTES 5 A401 10 A401 12 A401 17 A401 22 A401 23 A401 24 A401 25 A401 11 A401 25 A401 11 A401 DEMOLITION LEGEND EXISTING WALL TO REMAIN FIRE SPRINKLER (RE-CONFIGURE AS REQUIRED TO ACCOMMODATE NEW WORK) (N) MECHANICAL REGISTER (N) LIGHT FIXTURE (E) SUSPENDED GYP. BD. CEILING & GRID BY USG TO REMAIN (UL TYPE FC-CB, CLASS A, FLAME SPREAD RATING: 25 OR LESS & SMOKE DEVELOPMENT RATING: 50 OR LESS) (E) MECHANICAL GRILLE TO REMAIN (E) LIGHT FIXTURE TO REMAIN (E) ILLUMINATED EXIT SIGN TO REMAIN (E) CEILING ACCESS PANEL TO REMAIN EXISTING TO REMAIN PROPOSED S (E) SMOKE DETECTOR TO REMAIN (N) GYP. BD. CEILING / SOFFIT SEE SHEET A515 FOR SUSPENDED GYP. BD. CEILING DETAILS (E) GYP. BD. CEILING / SOFFIT TO REMAIN (N) ELECTRICAL OUTLETS (SEE ELECTRICAL DRAWINGS) 22.42 HAND SINK & FAUCET (SEE PLUMBING & KITCHEN CONSULTANT DRAWINGS) PREP SINK & FAUCET (SEE PLUMBING & KITCHEN CONSULTANT DRAWINGS) THREE COMPARTMENT SINK & FAUCET (SEE PLUMBING & KITCHEN CONSULTANT DRAWINGS) MOP SINK & FAUCET (SEE PLUMBING & KITCHEN CONSULTANT DRAWINGS) KITCHEN EQUIPMENT (SEE KITCHEN CONSULTANT DRAWINGS) GYP. BD. CEILING TO MATCH EXISTING 22.43 22.41 22.44 11.40 9.29 21 / A515 15 & 16 / ID101 26" X 20" STAINLESS STEEL WALL MOUNTED SPLASH GUARD (GSW MODEL# SP-S)5.72 COUNTER (SEE INTERIOR ELEVATIONS)6.22 26 A401 #DESCRIPTION MFR. TRUEREFRIGERATED DRAWERS (FOUR DRAWER) - 5" CASTORS1 MODEL # 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 TUC-67D-4-HC AMERICAN RANGESTOCK POT RANGE ARSP-18 AMERICAN RANGEFRYERAF-50HE GSWSTAINLESS STEEL WORK TABLE WT-EB3084 HOSHIZAKIICE MACHINE KM-350/520/660M_J(Z) HOSHIZAKIICE STORAGE BIN B-300SF CRATHCODOUBLE BOWL BUBBLER D25-4 -NOT USED - WARINGHEAVY DUTY ONE GALLON FOOD BLENDER CB15 TRUEREACH-IN REFRIGERATOR (SINGLE DOOR)T-19G-HC-FGD01 TRUEREACH-IN REFRIGERATOR (DOUBLE DOOR)T-49G-HC-FGD01 RINNAICOMMERCIAL GAS RICE COOKER RER-55ASN GSWSTAINLESS STEEL RICE COOKER STAND ES-RC3024 GSWSTAINLESS STEEL HAND SINK HS-1615W GSWSTAINLESS STEEL PREP SINK WITH DRAIN BOARD SE18181L GSWS.S. THREE COMPARTMENT SINK WITH TWO DRAIN BOARDS SH20243D GSWS.S. FLOOR MOUNTED MOP SINK SE2424FM CORNELIUSSODA DISPENSER (POST MIX, DROP-IN)2323 GENERAL70" THREE HOLE RANGE CHINESE WOK - MED GENERAL42" CHINESE RANGE CHINESE WOK - SM GENERALS.S. SERVICE COUNTER (19 ROUND PANS)- GSWS.S. SPLASH GUARD (WALL MOUNTED)SP-S2420 TRUEREFRIGERATED DRAWERS (TWO DRAWERS) - 5" CASTORS1A TUC-27D-2-HC EQUIPMENT LIST EQUIPMENT FOODSERVICE ACCESSORIES THREE COMPARTMENT SINK FAUCET ONE FAUCET SERVES ALL THREE SINKS (SEE CUT SHEET)23 25 26 27 28 5PR-8W12 STAINLESS STEEL MOP HANGER K-242 STAINLESS STEEL UTILITY SHELF K-246 METROWIRE SHELVING ANCHORED TO WALL (SEE NOTE BELOW)SUPER ERECTA CURTRONAIR CURTAIN 36" AIR-PRO ADVANCE TABCOMOP SINK FAUCET24 K-240 ADVANCE TABCO ADVANCE TABCO NOTES: 1) ALL EQUIPMENT SHALL BE ON 6" HIGH LEGS, COMMERCIAL CASTERS OR ON A 4" MASONRY CONTINUOUS COVED BASE 2) ANCHOR THE TOP SHELF OF EACH FOOD STORAGE WIRE RACK TO WALL STUDS USING FLEXIBLE STRAPS 3) ALL DOORS SHALL BE PROVIDED WITH CLOSERS (SELF CLOSING) ROOM NAME KITCHEN 101 FLOOR WALLS CEILING MT'L.HT. DOOR 11'-9" TRIMEXTERIORINTERIOR ROOM FINISH SCHEDULE GYP. BD. KITCHEN SUPPORT 102 12'-7"GYP. BD. SERVICE COUNTER 100 QT 14'-9"-GYP. BD. ABBREVIATIONS CT CERAMIC TILE PT PAINT QT QUARRY TILE 1. G.C. SHALL SUBMIT THE 3 SAMPLES OF ALL FINISHES TO ARCHITECT FOR APPROVAL. 2.SUBMITTALS MUST BE APPROVED BEFORE PLACING ORDERS WHERE MATERIALS ARE NOT RETURNABLE. 3.G.C. TO NOTIFY ARCHITECT OF ITEMS W/ LONG LEAD TIMES. 4.NO FINISH SUBSTITUTIONS MAY BE MADE W/O PRIOR WRITTEN AUTHORIZATION BY ARCHITECT. 5.ALL FINISHES SHALL BE APPLIED IN STRICT ACCORDANCE W/ MANUFACTURER'S SPECIFICATIONS. 6.APPLICATION OF INTERIOR FINISHES SHALL BE IN ACCORDANCE W/ WITH THE LATEST ADDITION OF THE CALIFORNIA BUILDING CODE AND CALIFORNIA GREEN BUILDING CODE (SEE TITLE SHEET AND CAL GREEN SHEETS). 7.THE MAXIMUM FLAME SPREAD CLASSIFICATION OF FINISH MATERIALS USED FOR INTERIOR FINISHES SHALL NOT EXCEED THAT SET FORTH IN THE LATEST ADDITION OF THE CALIFORNIA BUILDING CODE (SEE TITLE SHEET AND FINISH SCHEDULE). 8.THE SMOKE DENSITY OF MATERIALS OF FINISH MATERIALS USED FOR INTERIOR FINISHES SHALL NOT EXCEED THAT SET FORTH IN THE LATEST ADDITION OF THE CALIFORNIA BUILDING CODE (SEE TITLE SHEET AND FINISH SCHEDULE). 9.VERIFICATION OF COMPLIANCE WITH CALIFORNIA GREEN CODE REQUIREMENTS SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL BE PREPARED AND SUBMITTED BY THE CONTRACTOR. 10.ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. BEGINNING WORK IMPLIES ACCEPTANCE OF CONDITION. 11.ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY. WHEN THE WORK IS COMPLETE, IT SHALL BE FREE FROM BUCKLES, BUBBLES, OPEN JOINTS, OR IMPERFECTIONS. SEAMS SHALL BE KEPT IN ACCURATE ALIGNMENT ALONG BOTH COORDINATES. 12.GENERAL CONTRACTOR TO PROVIDE TEMPORARY PROTECTION FOR ALL INSTALLED FINISHES AS WORK PROGRESSES. 13.GYPSUM BOARD WALLS SHALL BE LEVEL 4 FINISH U.N.O 14.GYPSUM BOARD CEILINGS SHALL BE LEVEL 5 FINISH U.N.O. 15.PROVIDE MOISTURE RESISTANT GYPSUM BOARD IN AREAS SUBJECT TO MOISTURE (IE: TOILETS, KITCHEN'S). 16.TYPE AND INSTALLATION REQUIREMENTS OF SUBSTRATE FOR SPECIFIED FINISH(ES) SHALL BE FURNISHED AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND INDUSTRY STANDARDS. 17.ALL PAINT SHALL BE APPLIED IN ACCORDANCE W/ THE MANUFACTURER'S SPECIFICATION FOR THAT PARTICULAR SURFACE. 18.ALL WALLS SHALL RECEIVE ONE (1) PRIMER COAT & TWO (2) TOP COATS OF PAINT MINIMUM, U.N.O. PAINT FINISH SHALL HAVE CONSISTENT COVERAGE, FREE OF ROLLER OR BRUSH MARKS. 19.PAINT FINISH ON SURFACES INCLUDING: DOOR FRAMES, HANDRAILS, ELEVATOR DOORS, ETC. SHALL BE PAINTED SEMI-GLOSS, U.N.O. 20.ALL METAL ACCESS DOORS SHALL BE PAINTED TO MATCH ADJACENT WALL OR CEILING FINISH. ANY GRAPHICS ON DOORS SHALL BE REMOVED AND REAPPLIED AFTER PAINTING. 21.WALL COVERING SUB-CONTRACTOR TO SUBMIT SEAMING MOCK-UP SAMPLES ON GYP. BOARD OF ALL SPECIFIED WALL COVERINGS FOR APPLICATION PRIOR TO PLACEMENT OF ORDER. 22.FLOORING SHALL MEET ALL CURRENT NON-SLIP STANDARDS & REQUIREMENTS (WET & DRY CONDITION) SPECIFIED BY APPLICABLE CODES &/OR AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. CONTRACTOR SHALL PROVIDE NON-SLIP COATINGS AS NECESSARY TO MEET THESE REQUIREMENTS. 23.FLOORING SUB-CONTRACTORS TO SUBMIT SEAMING & INSTALLATION DIAGRAM W/ SUBMITTAL PACKAGE. 24.CONTRACTOR TO FIELD VERIFY EXISTING CONDITION OF FLOORS RECEIVING NEW FINISH. CONTRACTOR SHALL INCLUDE ALL REQUIRED FLOOR PREPARATION IN BID. PROVIDE PRICE TO FLOAT FLOOR WHERE NECESSARY TO ACHIEVE TOLERANCE OF 1/4" MAX. IN 10'-0'' SPAN. 25.ALL CERAMIC & VINYL COMPOSITION TILES TO BE INSTALLED W/ FULL TILE FROM TRANSITION AT DOOR & FULL TILE FROM WALL PERPENDICULAR TO DOOR, U.N.O. 26.G.C. TO COORDINATE THE INSTALLATION OF WALL BASE W/ ANY MILLWORK. 27.CERAMIC, PORCELAIN, AND OR QUARRY TILE GENERAL NOTES: A. ALL FLOORS IN WET AREAS (IE: KITCHEN AND TOILET ROOMS) SCHEDULED TO RECEIVED TILE, SHALL BE WATERPROOFED TO 6" A.F.F WITH REDGARD WATERPROOFING AND CRACK PREVENTION MEMBRANE OR APPROVED EQUAL PRIOR TO APPLICATION OF TILE. B. PROVIDE SOFT JOINT ON THE INTERIOR AT A MAXIMUM OF 25' IN EACH DIRECTION EXCEPT WHERE EXPOSED TO DIRECT SUNLIGHT (HEAT) OR MOISTURE A MAXIMUM OF 12' IN EACH DIRECTION. PERIMETER JOINTS AND MOVEMENT JOINTS ARE REQUIRED WHERE TILE WORK ABUTS RESTRAINING SURFACES SUCH AS PERIMETER WALLS, DISSIMILAR FLOOR FINISHES, CURBS, COLUMNS, PIPES, CEILINGS, AND WHERE CHANGES OCCUR IN BACKING MATERIALS, BUT NOT AT DRAIN STRAINERS. CHANGES OF PLANE, INTERIOR MOVEMENT JOINTS REQUIRED AT ALL INSIDE AND OUTSIDE CORNERS. C. ALL EXPANSION, COLD, ISOLATION CONTRACTION AND SEISMIC JOINTS IN THE STRUCTURE SHOULD CONTINUE THROUGH THE TILE WORK, INCLUDING SUCH JOINTS AT VERTICAL SURFACES. D. TILE GROUT SHALL BE SEALED W/ AQUAMIX "SEALER'S CHOICE" OR APPROVED EQUAL. 28.AFTER CLEANING, THE CONTRACTOR SHALL PROVIDE TWO (2) APPLICATIONS OF AN APPROVED NON-SLIP WAX TO RESILIENT TILE FLOOR, WHICH SHALL BE THOROUGHLY MACHINE-BUFFED & LEFT IN CONDITION ENTIRELY ACCEPTABLE TO ARCHITECT. 31. CONTRACTOR SHALL PATCH & REPAIR ANY EXISTING OR NEW FINISHES TO MATCH EXISTING OR NEW FINISHES THAT ARE COMPROMISED BY THE NEW WORK QT QT 27 A401 CT & PAINTED GYP. BD. CT & FRP PANELS OVER GYP. BD. - CT & FRP PANELS OVER GYP. BD. CT & FRP OVER GYP. BD. CT & FRP OVER GYP. BD.PT - GYP. BD.GYPSUM BOARD SS SOLID SURFACE FINISH NOTES FRP FIBER REINFORCED POLYMER SEE INTERIOR ELEVATIONS ON SHEET A401 FOR ADDITIONAL FINISH INFORMATION FLOORING INCLUDES 4" TALL (MINIMUM) 3/8" COVED QUARRY TILE BASE FINISH SCHEDULE NOTES KITCHEN HOOD UTILITY CABINET (ATTACH TO WALL WITH 5/16" x 1-1/2" SELF TAPPING SCREWS EQUALLY SPACED (TOP & BOTTOM) TO METAL STUDS (MIN. OF 3 STUDS)23.38 20 A515 20 A515 20 A515 PROVIDE DOOR CLOSER AS REQUIRED (DOOR SHALL BE SELF CLOSING)8.05 SUITE FC2 BELOW INDICATED BY SOLID HATCH (E) ROOF TOP ENCLOSURE WALL (E) HVAC UNIT (N.I.C.) (E) HVAC UNIT (N.I.C.) D23.20 HVAC UNIT 23.35 23.35 23.20B MAKE-UP AIR UNIT 22.10 70.01 7.72 7.72C 7.72B 7.72B 7.53 7.53 22.10B SUITE FC2 BELOW INDICATED BY SOLID HATCH (E) ROOF TOP ENCLOSURE WALL (E) HVAC UNIT (N.I.C.) (E) HVAC UNIT (N.I.C.) 22.10 70.01 7.72 7.53 7.53 7.72C 22.10B 23.20C 4" MECHANICAL EQUIPMENT (SEE MECHANICAL DRAWINGS) TOP OF CURB TO REMAIN LEVEL (E) ROOF SHEATHING 22 GA GALV. SHEET METAL FLASHING (N) LEVELING CURB- RIPPED AS REQUIRED FOR ROOF SLOPE (SEE DETAIL 30B) 1/2" PLYWOOD MECHANICAL FASTENER W/ 1/4" RUBBER GASKET / SEAL 40 MIL SELF-ADHERING MEMBRANE "CLASS A" SINGLE PLY ROOFING O/ RECOVERY BOARD NEW BEAM (SEE DETAIL 30B) BASE FLASHING MEMBRANE A ARCHITECTURAL DETAIL B STRUCTURAL DETAIL AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK A102 ROOF PLAN SCALE: 1/4"=1'-0" 0'8'2'4' 7.72 7.72B 23.35 22.10 23.20 7.53 70.01 (E) CURBED ROOF OPENING FOR HVAC UNITS TO REMAIN MODIFY (E) CURBED ROOF OPENING AS REQUIRED TO INSTALL NEW EXHAUST FAN (E) EXHAUST FAN TO TO BE REPLACED (SEE MECHANICAL DRAWINGS) (E) PIPE PENETRATION THRU ROOF TO REMAIN (SEE PLUMBING DRAWINGS) (E) MECHANICAL UNIT TO REMAIN (MECHANICAL DRAWINGS) CLASS 'A' SINGLE PLY ROOF TO REMAIN (PROTECT IN PLACE) LINE OF WALL OR STRUCTURE BELOW (SEE FLOOR PLAN & RCP) ROOF PLAN GENERAL NOTES #DESCRIPTION DETAIL ROOF PLAN KEY NOTES A. ALL ROOF ELEVATIONS ARE REFERENCED FROM TOP OF FLOOR SLAB (FIN. FLR. ELEV. OF 0'-0") OR FROM DATUM LINE (0'-0") WHERE OCCURS, SEE BUILDING ELEVATIONS & SECTIONS TO LOCATE DATUM LINE B. ALL ROOF WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE ROOFING MANUFACTURER'S RECOMMENDATIONS AND APPROVED DETAILS C.THE CONTRACTOR SHALL VERIFY THAT ALL AREAS TO RECEIVE BUILT-UP ROOFING OR SINGLE PLY ROOFING MEMBRANE ARE PROVIDED WITH POSITIVE DRAINAGE AT 1/4" PER FOOT MINIMUM PRIOR TO ROOFING D.THE CONTRACTOR SHALL VERIFY THAT ALL AREAS TO RECEIVE FIBERGLASS SHINGLES ARE PROVIDED WITH POSITIVE DRAINAGE PRIOR TO ROOFING (PROVIDE MINIMUM 4:12 PITCH) E. VERIFY SIZES AND LOCATIONS OF ALL OPENINGS, PLATFORMS, ETC., WITH RESPECTIVE CONTRACTORS F. ALL CRICKETS / FLASHING SHALL SLOPE A MINIMUM OF 1/2" PER FOOT G. PROVIDE CRICKETS / FLASHING AROUND ALL CURBED ROOF OPENINGS H.BROADCAST FREE GRANULES INTO EXCESSIVE ASPHALT AND AT SIDE & END LAPS OF THE CAP SHEET I. ALL ROOF DIMENSIONS ARE MEASURED TO THE FACE OF SHEATHING, U.N.O. J. BUILT-UP ROOFING: ON CRICKETS STEEPER THAN 1" PER 1'-0" AND ON VERTICAL SURFACES, USE CLASS 'A' MODIFIED BITUMEN MINERAL-SURFACED ROOFING SYSTEM (AS REQUIRED, TYPICAL) K.ALL MECHANICAL, PLUMBING AND ELECTRICAL TO RECEIVE PILLOW BLOCKS AS REQUIRED (MAX. 4'-0" APART) L.GENERAL CONTRACTOR TO PROVIDE ROOF JACKS AT ALL EXPOSED ROOF PENETRATIONS M. PROVIDE FLEXIBLE PENETRATIONS AS REQUIRED (VERIFY COLOR WITH ARCHITECT PRIOR TO PROCEEDING) N. PAINT ALL EXPOSED IRON AND GALVANIZED IRON PIPES, CONDUIT, ETC. (VERIFY COLOR WITH ARCHITECT PRIOR TO PROCEEDING) O. ALL ROOF MOUNTED EQUIPMENT (IE HOODS, VENTILATORS, ETC.) SHALL BE PAINTED WITH TWO (2) COATS OF EXTERIOR SEMI-GLOSS PAINT (VERIFY COLOR WITH ARCHITECT PRIOR TO PROCEEDING) 23.20B (E) MECHANICAL UNIT TO BE REPLACED (MECHANICAL DRAWINGS) SCALE:16 DEMOLITION ROOF PLAN 1/4" = 1'-0" NORTH SCALE:26 PROPOSED ROOF PLAN 1/4" = 1'-0" NORTH SCALE: 1/4"=1'-0" 0'8'2'4' 7.72C MODIFY (E) CURBED ROOF OPENING FOR NEW HVAC EQUIPMENT 30 / - SCALE:30 ROOFTOP HOUSE KEEPING PAD 3"=1'-0" 22.10B (E) ROOF VENT TO BE MODIFIED TO ACCOMMODATE CLEARANCE (SEE MECHANICAL DRAWINGS) 23.20C PROVIDE PRE-FABRICATED CURB WITH NEW HVAC UNIT (FILTER SECTIONS) (MODIFY EXISTING CURBED OPENING TO ACCOMMODATE BLOWER SECTION) 7' - 0 " B. O . H O O D & B. O . H O O D U T I L I T Y C A B I N E T 11 ' - 9 " SU S P E N D E D G Y P . B D . C E I L I N G H E I G H T 9' - 0 " SO F F I T H E I G H T 2 OUTLINE OF HOOD EXISTING FRP WALL PANELS TO REMAIN EXISTING CERAMIC WALL TILE TO REMAIN EXISTING QUARRY TILE BASE TO REMAIN EXISTING DOOR TO REMAIN (PAINT) KITCHEN HOOD UTILITY CABINET 12 ' - 7 " SU S P E N D E D G Y P . B D . C E I L I N G H E I G H T 14 ' - 9 " GY P . B D . C E I L I N G H E I G H T 2' - 9 1 / 2 " SE R V I C E CO U N T E R 2'- 7 1 / 2 " LO W W A L L 14 15 4 9 17 22 7 21EXISTING WALL TILE TO REMAIN QUARRY TILE BASE TO MATCH EXISTING EXISTING FRP WALL PANELS TO REMAIN EXISTING WALL TILE TO REMAIN PAINT EXISTING GYP. BD. WALL 2' - 9 1 / 2 " SI N K & CO U N T E R H E I G H T 14 ' - 9 " GY P . B D . C E I L I N G H E I G H T 7'- 0 " B. O . S U S P E N D E D W A L L 20 7 13 A510 EXISTING CERAMIC WALL TILE (BEYOND) TO REMAIN QUARRY TILE BASE TO MATCH EXISTING EXISTING WALL TILE TO REMAIN (PATCH & REPAIR) SEE DETAIL 27 ON THIS SHEET FOR FINISH EXISTING QUARRY TILE BASE (BEYOND) TO REMAIN STAINLESS STEEL KITCHEN HOOD SIDE PANEL (SEE MECHANICAL DRAWINGS) STAINLESS STEEL BACKSPLASH (BEYOND) SEE DETAIL 21 ON SHEET A510 & KITCHEN HOOD ACCESSORY DETAILS IN MECHANICAL DRAWINGS 11 ' - 9 " SU S P E N D E D G Y P . B D . C E I L I N G H E I G H T 12 ' - 7 " SU S P E N D E D G Y P . B D . C E I L I N G H E I G H T 16 5 6 (E) WATER HEATER EXISTING WALL TILE TO REMAIN EXISTING QUARRY TILE BASE TO REMAIN EXISTING FRP WALL PANELS TO REMAIN 2' - 7 1 / 2 " P. O . S . CO U N T E R HE I G H T 14 ' - 9 " GY P . B D . C E I L I N G H E I G H T 11 ' - 9 " SU S P E N D E D G Y P . B D . C E I L I N G H E I G H T 9' - 0 " SO F F I T 7' - 0 " B. O . H O O D & T. O . B A C K S P L A S H 14 ' - 9 " B. O . S T R U C T U R E 2' - 3 " M I N . CL E A R CARRY S.S. BACKSPLASH TO CEILING FOR THIS END PANEL 18 20 19 3 3 13 12 2EXISTING WALL TILE TO REMAIN EXISTING QUARRY TILE BASE TO REMAIN PAINT EXISTING GYP. BD. WALL STAINLESS STEEL BACKSPLASH (SEE KITCHEN HOOD ACCESSORY DETAILS IN MECHANICAL DRAWINGS) KITCHEN HOOD FRP PANELS TO MATCH EXISTING OVER GYP. BD. SOFFIT 11 ' - 9 " SU S P E N D E D G Y P . B D . C E I L I N G H E I G H T 7'- 0 " B. O . H O O D H E I G H T 9'- 0 " SO F F I T & P E R F . P A N E L H E I G H T ±1 4 ' - 9 " B. O . C O N C R E T E S T R U C T U R E ±5 ' - 3 " V. I . F . 6" EXHAUST HOOD 14 15 (E) ELECTRICAL PANEL 11 1312 EXISTING FRP WALL PANELS TO REMAIN EXISTING WALL TILE TO REMAIN QUARRY TILE BASE TO MATCH EXISTING FRP WALL PANELS TO MATCH EXISTING AT SUSPENDED WALL 12 ' - 7 " SU S P E N D E D G Y P . B D . C E I L I N G H E I G H T 6' - 8 " B. O . W A T E R H E A T E R 4 22 16 (E) WATER HEATEREXISTING FRP WALL PANELS TO REMAIN EXISTING WALL TILE TO REMAIN QUARRY TILE BASE TO MATCH EXISTING 14 ' - 9 " GY P . B D . C E I L I N G H E I G H T 2'- 9 1 / 2 " SE R V I C E CO U N T E R HE I G H T 2' - 7 1 / 2 " P. O . S . CO U N T E R HE I G H T 21 18 13 A510 11 A510 EXISTING WALL TILE TO REMAIN QUARRY TILE BASE TO MATCH EXISTING GYP. BD. (PAINTED) 11 ' - 9 " SU S P E N D E D G Y P . B D . C E I L I N G H E I G H T 14 ' - 9 " GY P . B D . C E I L I N G H E I G H T 2'- 9 1 / 2 " SE R V I C E CO U N T E R 2' - 7 1 / 2 " LO W W A L L 1'-6" MIN. 11 10 1A 1 7 21 EXISTING WALL TILE TO REMAIN EXISTING QUARRY TILE BASE TO REMAIN EXISTING FRP WALL PANELS TO REMAIN 14 ' - 9 " GY P . B D . C E I L I N G H E I G H T 2'- 7 1 / 2 " CO U N T E R & LO W W A L L 2'- 9 1 / 2 " SE R V I C E CO U N T E R 18 21 WOOD WALL PANELSTILE BASE TO MATCH COUNTER METAL EDGE TRIM SOLID SURFACE COUNTERTOP OVERHANG 1. PREFERRED VERTICAL CLEARANCE BETWEEN UPPER AND LOWER CASEWORK IS 24". IN NO CASE SHOULD THE VERTICAL CLEARANCE BE LESS THAN 18". 2. PROVIDE A 2" VALANCE TO SHIELD TASK LIGHTING MOUNTED ON THE UNDERSIDE OF THE UPPER CABINETS. ENSURE THAT THE FIXTURE IS PROPERLY INTEGRATED INTO THE DESIGN OF THE UPPER CASEWORK. 3. PROVIDE EDGE PROTECTION, SUCH AS METAL EDGES FOR CASEWORK THAT IS LOCATED IN AN AREA WITH WHEELED TRAFFIC FOR DAMAGE PREVENTION. EDGE PROTECTION SHOULD BE INTEGRATED IN THE CASEWORK DESIGN. 4. USE 4" HIGH TOE SPACE ON ALL BASE CABINETS 5. CONTRACTOR TO PROVIDE WATER LINES TO REFRIGERATOR, COFFEE MAKER AND WATER DISPENSER AS DIRECTED BY ANTHEM PROJECT MANAGER. SHUT-OFF VALVES SHALL BE LOCATED UNDER THE SINK AND LABELED. INTERIOR ELEVATION GENERAL NOTES AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK A401 INTERIOR ELEVATIONS SCALE:5 INTERIOR ELEVATION 1/4" = 1'-0" SCALE:10 INTERIOR ELEVATION 1/4" = 1'-0" SCALE:11 INTERIOR ELEVATION 1/4" = 1'-0" SCALE:12 INTERIOR ELEVATION 1/4" = 1'-0" SCALE:17 INTERIOR ELEVATION 1/4" = 1'-0" SCALE:22 INTERIOR ELEVATION 1/4" = 1'-0" SCALE:23 INTERIOR ELEVATION 1/4" = 1'-0" SCALE:24 INTERIOR ELEVATION 1/4" = 1'-0" SCALE:25 INTERIOR ELEVATION 1/4" = 1'-0" SCALE: 1/4"=1'-0" 0'8'2'4' SCALE: 1/4"=1'-0" 0'8'2'4' SCALE: 1/4"=1'-0" 0'8'2'4' SCALE: 1/4"=1'-0" 0'8'2'4' SCALE: 1/4"=1'-0" 0'8'2'4' SCALE: 1/4"=1'-0" 0'8'2'4' SCALE: 1/4"=1'-0" 0'8'2'4' SCALE: 1/4"=1'-0" 0'8'2'4' SCALE: 1/4"=1'-0" 0'8'2'4' SCALE:26 INTERIOR ELEVATION 1/4" = 1'-0" #DESCRIPTION MFR. TRUEREFRIGERATED DRAWERS (FOUR DRAWER) - 5" CASTORS1 MODEL # 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 TUC-67D-4-HC AMERICAN RANGESTOCK POT RANGE ARSP-18 AMERICAN RANGEFRYERAF-50HE GSWSTAINLESS STEEL WORK TABLE WT-EB3084 HOSHIZAKIICE MACHINE KM-350/520/660M_J(Z) HOSHIZAKIICE STORAGE BIN B-300SF CRATHCODOUBLE BOWL BUBBLER D25-4 -NOT USED - WARINGHEAVY DUTY ONE GALLON FOOD BLENDER CB15 TRUEREACH-IN REFRIGERATOR (SINGLE DOOR)T-19G-HC-FGD01 TRUEREACH-IN REFRIGERATOR (DOUBLE DOOR)T-49G-HC-FGD01 RINNAICOMMERCIAL GAS RICE COOKER RER-55ASN GSWSTAINLESS STEEL RICE COOKER STAND ES-RC3024 GSWSTAINLESS STEEL HAND SINK HS-1615W GSWSTAINLESS STEEL PREP SINK WITH DRAIN BOARD SE18181L GSWS.S. THREE COMPARTMENT SINK WITH TWO DRAIN BOARDS SH20243D GSWS.S. FLOOR MOUNTED MOP SINK SE2424FM CORNELIUSSODA DISPENSER (POST MIX, DROP-IN)2323 GENERAL70" THREE HOLE RANGE CHINESE WOK - MED GENERAL42" CHINESE RANGE CHINESE WOK - SM GENERALS.S. SERVICE COUNTER (19 ROUND PANS)- GSWS.S. SPLASH GUARD (WALL MOUNTED)SP-S2420 TRUEREFRIGERATED DRAWERS (TWO DRAWERS) - 5" CASTORS1A TUC-27D-2-HC EQUIPMENT LIST EQUIPMENT FOODSERVICE ACCESSORIES THREE COMPARTMENT SINK FAUCET ONE FAUCET SERVES ALL THREE SINKS (SEE CUT SHEET)23 25 26 27 28 5PR-8W12 STAINLESS STEEL MOP HANGER K-242 STAINLESS STEEL UTILITY SHELF K-246 METROWIRE SHELVING ANCHORED TO WALL (SEE NOTE BELOW)SUPER ERECTA CURTRONAIR CURTAIN 36" AIR-PRO ADVANCE TABCOMOP SINK FAUCET24 K-240 ADVANCE TABCO ADVANCE TABCO NOTES: 1) ALL EQUIPMENT SHALL BE ON 6" HIGH LEGS, COMMERCIAL CASTERS OR ON A 4" MASONRY CONTINUOUS COVED BASE 2) ANCHOR THE TOP SHELF OF EACH FOOD STORAGE WIRE RACK TO WALL STUDS USING FLEXIBLE STRAPS 3) ALL DOORS SHALL BE PROVIDED WITH CLOSERS (SELF CLOSING) SCALE: 1/4"=1'-0" 0'8'2'4' SCALE:27 FRONT COUNTER ELEVATION NONE SCALE: 1/4"=1'-0" 0'8'2'4' INTERIOR METAL STUD SCHEDULE SCALE:1 INTERIOR METAL STUD SCHEDULE NONE BETWEEN SUPPORTS HEIGHT (3) #10 EACH END 1 5/8" x 6" x 18 GA. 1 3/8" x 6" x 18 GA. 1 3/8" x 4" x 20 GA. 1 1/4" x 3 5/8" x 20 GA. 1 1/4" x 3 5/8" x 20 GA.6' OR UNDER 6'-1" TO 12' 12'-1" TO 16' 16'-1" TO 20' 20'-1" TO 25' 15'-1" TO 18'-0" 0' TO 15'-0" 18'-1' TO 20'-0" 20'-1' TO 26'-0" 26'-1" TO 30'-0" SCREWSSIZEBRACING LENGTH REMARKICC-ESR-3064P INTERIOR METAL STUD SIZE & SPACING (3) #10 EACH END (3) #10 EACH END (4) #10 EACH END (4) #10 EACH END 1 1/4" x 3 5/8" x 20 GA. @ 16" O.C. 1 1/4" x 3 5/8" x 18 GA. @ 16" O.C. 1 1/4" x 3 5/8" x 16 GA. @ 16" O.C. 1 1/4" x 6" x 18 GA. @ 16" O.C. 1 1/4" x 6" x 16 GA. @ 16" O.C. 2 1/2" x 8" x 14 GA. @ 16" O.C.30'-1" TO 45'-0" A) SECTION B) PLAN B (3) #10 SCREWS EACH END FLANGE BRACING BRACING SPLICE MINIMUM (3) #10 SCREWS PER BLOCK @ JOISTED CEILINGS ONLY TRACK BLOCKING (@ SPLICE ONLY) METAL STUD GYPSUM BOARD WHERE OCCURS PARTITION STUDS TRACK BLOCKING (@ SPLICE ONLY) BEND ENDS UP & SCREW TO STUD w/ (2) #10 TEK SCREWS (1) #10 SCREW PER STUD FLANGE BRACINGWALL MATERIAL UNDERSIDE OF STRUCTURE FLANGE BRACING: 16 GA. 1 1/2" WIDE METAL STRAP OR 1 1/2" COLD-ROLLED CHANNEL TRACK BLOCKING (@ SPLICE ONLY) FLOOR SLAB 27A - USE STUD WALL FLANGE BRACING 4'-0" O.C. ON SIDE(S) OF PARTITION WHERE GYPSUM BOARD SHEATHING DOES NOT OCCUR, INCLUDING ABOVE THE CEILING.4'- 0 " O . C . M A X . TY P I C A L 4' - 0 " O . C . M A X . TY P I C A L C) PARALLEL TO ROOF STRUCTURE D) PERPENDICULAR TO ROOF STRUCTURE (CONCRETE FILLED METAL DECK) (CONCRETE FILLED METAL DECK) METAL STUD BRACING @ 4'-0" O.C. ON ALTERNATING SIDES OF THE WALL, SEE SCHEDULE FOR SIZE (DETAIL 1 THIS SHEET) 6" 3/8" DIA. HILTI KB-TZ WITH 2" MIN EMBED EACH SIDE & 2" FROM EACH END CENTERED ON LOWER FLUTES (ESR 1917) 1" 1" METAL STUD BRACING @ 4'-0" O.C. ON ALTERNATING SIDES OF THE WALL, SEE SCHEDULE FOR SIZE (DETAIL 1 THIS SHEET) 2" TYP. 2" TYP. 12 GA. CLIP ANGLE 12 GA. CLIP ANGLE UNDERSIDE OF CONCRETE FILLED METAL DECK / CONCRETE DECK UNDERSIDE OF CONCRETE FILLED METAL DECK / CONCRETE DECK TWO (2) 3/8" DIA. HILTI KB-TZ WITH 2" MIN EMBED EACH SIDE (4 TOTAL) & 2" FROM EACH END CENTERED ON LOWER FLUTES (ESR 1917) 16 GA. SHEET METAL BACKING PLATE- SEE NOTES FOR SIZE NOTES 1. EXTEND BACKING PLATE ACROSS (3) STUDS MINIMUM 2. EXTEND ALL BACKING PLATES TO NEXT STUD BEYOND END OF SUPPORTED ITEM 3. LET-IN BACKING TO WALL STUD FLANGES & SCREW AS NOTED, FLUSH TO FACE OF FLANGE. FLANGES SHALL NOT BE CUT UNLESS FILLED WITH WELDED PLATE DETAIL B SPECIAL APPLICATIONS * COORDINATE EXTENT OF BACKING WITH OWNER REPRESENTATIVE TYPICAL APPLICATIONS * BASE & WALL CABINETS AND SHELVES * SHOWER SEATS * GRAB BARS * CRASH GUARDS * TOILET ACCESSORIES (SURFACE MOUNTED) * WALL MOUNTED DOOR STOPS * MARKER & TACK BOARDS * FRAMED SIGNAGE * FIRE EXTINGUISHER BRACKETS * EQUIPMENT DISTRIBUTING LESS THAN 20# PER STUD (CENTER OF GRAVITY LESS THAN 6" FROM FACE OF STUD UNLESS SPECIFICALLY ALLOWED BY DESIGNER OF RECORD) NOTE: 150 LBS MAX/STUD DETAIL A WALL STUD (3) #10 x 1/2" LOW-PROFILE HEAD SCREWS @ EACH STUD, TYPICAL 600T150-54 TRACK NOTCH OVER STUDS (ALT: 8"x14GAx3 STUDS) (3) #10 x 1/2" LOW-PROFILE HEAD SCREWS @ EACH STUD, TYPICAL ALTERNATE BACKING PRODUCT: DANBACK® FLEXIBLE WOOD BACKING** BY CLARK DIETRICH **USE FlamePro® WHERE REQUIRED C) TRACK PERPENDICULAR TO FLUTES D) TRACK PARALLEL TO FLUTES - TRACK SHEET METAL 2"W x 16"L x 16 GA @ 2'-0" O.C. & 6" FROM ENDS 3/8" DIA. HILTI KB-TZ W/ 2" MIN EMBED (ESR-1917) 24" O.C. EA. SIDE, AND 2" FROM ENDS & CENTERED ON FLUTES (ESR 1663) (2) #10 SCREWS PER SHEET METAL PLATE (STAND-OFF WASHERS PER PRE-APPROVAL) 3/8" DIA. HILTI KB-TZ W/ 2" MIN EMBED (ESR-1917) 24" O.C. SIDE, AND 2" FROM EA. END CENTERED ON FLUTES (ESR 1663) T.O. STUD 2" C #8 SCREW CENTER OF SLOT PER PRE-APPROVAL SLOTTED CEILING TRACK (16 GAUGE) 1/ 2 " PER (CONCRETE FILLED METAL DECK) (CONCRETE FILLED METAL DECK) F) OFFSET TO BEAM E) ON BEAM 2" 2" **HILTI 'X-U' POWER ACTUATED FASTENERS @ 32" O.C. (2) #10 S.M.S. @ 2'-0" O.C. Z CLIP, 16 GA @ 2'-0" O.C. C 6" MAX. C **HILTI 'X-U' POWER ACTUATED FASTENERS @ 2'-0" O.C. **#12 SELF TAPPING SCREWS CAN BE USED IN LIEU OF HILTI 'X-U' FASTENER IF STEAL FLANGE IS LESS THEN 1/4" THICK. NONRATED PER PER VA R I E S 2 " MA X . A) TRACK PERPENDICULAR TO FLUTES B) TRACK PARALLEL TO FLUTES - TRACK 1/ 2 " SHEET METAL 2"W x 16"L x 14 GA @ 2'-0" O.C. & 6" FROM ENDS (1) #10 SCREWS EA. SIDE PER SHEET METAL PLATE (STAND-OFF WASHERS PER PRE-APPROVAL) (2) #10 SCREWS PER SHEET METAL PLATE (STAND-OFF WASHERS PER PRE-APPROVAL) #8 SCREW CENTER OF SLOT PER PRE-APPROVAL SLOTTED CEILING TRACK 2" C T.O. STUD PER (METAL DECK) (METAL DECK) METAL STUD BRACING @ 4'-0" O.C. ON ALTERNATING SIDES OF THE WALL, SEE SCHEDULE FOR SIZE (DETAIL 1 THIS SHEET) 6" A) PARALLEL TO ROOF STRUCTURE B) PERPENDICULAR TO ROOF STRUCTURE TWO (2) #10 S.M.S. EACH SIDE (4 TOTAL) & 2" FROM EACH END CENTERED ON LOWER FLUTES UNDERSIDE OF METAL DECK 1" 2" TYP.1" (METAL DECK) (METAL DECK) METAL STUD BRACING @ 4'-0" O.C. ON ALTERNATING SIDES OF THE WALL, SEE SCHEDULE FOR SIZE (DETAIL 1 THIS SHEET) TWO (2) #10 S.M.S. EACH SIDE (4 TOTAL) & 2" FROM EACH END CENTERED ON LOWER FLUTES 12 GA. CLIP ANGLE 12 GA. CLIP ANGLE 2" TYP. UNDERSIDE OF METAL DECK H) OFFSET TO BEAM G) ON BEAM 2" 2" WHERE OFFSET DISTANCE EXCEEDS 6" PROVIDE PER DETAIL 22/A511 USE METAL-LITE, INC. "SLOTTED TRACK SYSTEM" OR SLIPTRACK SYSTEMS, INC. "SLP-TRK" Z CLIP, 2"x 2"x 2"x 3" LONG, 16 GA (2) #10 S.M.S. @ 2'-0" O.C. (2) #10 S.M.S. @ 2'-0" O.C. Z CLIP, 16 GA @ 2'-0" O.C. 6" MAX. C C RATED **HILTI 'X-U' POWER ACTUATED FASTENERS @ 32" O.C. **HILTI 'X-U' POWER ACTUATED FASTENERS @ 2'-0" O.C. PER PER VARIES 2" MAX. SCALE:26 FIRE EXTINGUISHER CABINET @ RATED WALL 1-1/2" = 1'-0" AT 1 HR. CONDITIONS WRAP 5/8" TYPE "X" GYP. BD. INTO CAVITY BEHIND CABINET AND FIRE TAPE METAL SEMI-RECESSED FIRE EXTINGUISHER CABINET ACOUSTIC INSULATION WHERE OCCURS SEMI-RECESSED FIRE EXTINGUISHER CABINET SEE MANUFACTURER FOR ROUGH OPENING 5/8" GYP. BD. BEHIND CABINET RATED PARTITION AS SCHEDULED PLAN SECTION 48 " M A X . A . F . F . T O ℄ O F H A N D L E - B - PERPENDICULAR TO FLUTES A - PARALLEL TO FLUTES C1 - OFFSET OF BEAM UL # HW-D-0160 C2 - OFFSET OF BEAM GAP PER UL DESIGNS THIS SHEET SLIPTRACK SYSTEMS SLIP-TRACK BRAND SLOTTED TRACK 5/8" DEFLECTION GAP METAL FRAMING PER 26/A510 4 #10 SCREWS TYPE X GYP BDFIRE-RESISTIVE JOINT SPRAY OVER MINERAL WOOL GYP. BD. LAYERS AS REQ'D. SEE UL DESIGNS THIS SHEET (E) SPRAY-ON FIRE RESISTIVE MATERIALS (E) BEAM MINERAL WOOL IN FLUTE CAVITY 0.145"Ø POWDER DRIVEN FASTENER - 1 1/4" EMBED @ 24" O.C. MAX. (ESR 1663) SEE FASTENER MANUFACTURER ICBO FOR FASTENER CAPACITY OR PER ENGINEER OF RECORD SCALE:6 TOP OF WALL - FIRE RATED 3" = 1'-0" GENERAL NOTES-SEISMIC ZONES IBC D-F, CBC3-4: ALL METAL STUD PARTITION TYPES SHALL COMPLY WITH PARTITION TYPE GENERAL NOTES, AND ALL METAL STUDS SHALL BE MIN 20 GA, UNO. ALL CMU PARTITION TYPES SHALL COMPLY WITH PARTITION TYPE GENERAL NOTES, AND REINFORCING AS INDICATED ON THE STRUCTURAL DRAWINGS, UNO. (SEE GENERAL NOTES ON SHEET G201 FOR WALL TYPE NOTES) METAL STUD PARTITION GENERAL NOTES SUSPENDED WALL NOTES: 1.TYPE "X" GYPSUM WALL BOARD SPECIFIED THROUGHOUT UNLESS OTHERWISE SPECIFIED. PROVIDE MOISTER RESISTANT GYP BOARD AT ALL WET WALLS. PROVIDE TILE BACKER BOARD ON ALL WALLS WITH TILE. FIRE RESISTANT ASSEMBLIES TILE BACKER BOARD SHALL BE PROVIDED OVER THE FIRE RESISTANT SYSTEM. 2.INSTALL CONTROL JOINTS MAXIMUM 30'-0" O.C. INTERVAL WHERE A CONTROL JOINT OCCURS IN AN ACOUSTICAL OR FIRE RATED SYSTEM, BLOCKING SHALL BE PROVIDED BEHIND THE CONTROL JOINT BY USING A BACKING MATERIAL SUCH AS 5/8" TYPE "X" GYP BOARD, MINERAL FILLER OR OTHER TESTED EQUIVALENT. 3.CONFORM TO DETAILED REQUIREMENTS OF DESIGNATED TESTING AUTHORITY NUMBERS AT ALL WALLS. WALLS DESIGNATED AS "BASED ON" VARY AS NOTED IN PARENTHESIS. SEE STRUCTURAL SHEAR WALLS SCHEDULE FOR SHEAR WALL ATTACHMENT AND EDGE BLOCKING REQUIREMENTS WHERE APPLICABLE. STRUCTURAL SHEAR WALL SCHEDULE OVERRIDES LISTED ASSEMBLY ATTACHMENT AND BLOCKING REQUIREMENTS ONLY WHEN MORE RESTRICTIVE. 4.WALL TYPES STATED AS "BASED ON" A LISTED ASSEMBLY MIGHT VARY IN STUD SIZE. NO EXACT LISTED ASSEMBLY EXISTS. PER GA-600-2012 P.9 ITEM 16, "GREATER STUD SIZES (DEPTH) SHALL BE PERMITTED TO BE USED IN METAL - OR WOOD - STUD SYSTEMS." THESE WALLS CAN ALSO BE SHOWN TO MEET THE REQUIRED FIRE RESISTIVE RATING BY THE CALCULATION METHOD PER SECTION 703.3.3 AND SECTION 721 IF REQUIRED. 5.WALL TYPES STATED AS "BASED ON" A LISTED ASSEMBLY MIGHT VARY DUE TO ADDITION OF EXTRA LAYER(S) OF ELEMENTS. NO EXACT LISTED ASSEMBLY EXISTS. PER GA-600-2012 P. ITEM 22, "ADDITIONAL LAYERS OF TYPE "x" OR REGULAR GYP BOARD SHALL BE PERMITTED TO BE ADDED TO ANY SYSTEM." FASTENERS SPECIFIED FOR THE ATTACHMENT OF GYP BOARD APPLIED OVER THE ADDITIONAL LAYER(S) OF ELEMENTS SHALL BE INCREASED BY NOT LESS THAN THE THICKNESS OF THE ADDITIONAL LAYER(S). 6.METALLIC OUTLET BOXES SHALL BE PERMITTED TO BE INSTALLED IN WOOD AND STEEL STUD WALLS OR PARTITIONS HAVING GYPSUM BOARD FACINGS AND CLASSIFIED AS TWO HOURS OR LESS. THE SURFACE AREA OF INDIVIDUAL BOXES SHALL NOT EXCEED 16 SQUARE INCHES. THE AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE FEET. BOXES LOCATED ON OPPOSITE SIDES OF WALLS OR PARTITIONS SHALL BE IN SEPARATE STUD CAVITIES AND SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. APPROVED NONMETALLIC BOXES SHALL BE PERMITTED AS ALLOWED BY LOCAL CODE. ELEVATION SECTION DUCT PENETRATION ELEVATION SECTION BEAM PENETRATION SECTIONELEVATION PENETRATIONS OF ACOUSTICAL PARTITIONS BY DUCT, CONDUIT, CABLE, PIPES ETC. SHALL BE ACOUSTICALLY SEALED AS SHOWN. ANY GAP LARGER THAN 1/2" SHALL BE COVERED WITH GYPSUM BOARD, LAPPED A MINIMUM OF 2" AND SCREWED BEFORE USING ACOUSTICAL SEALANT. CLOSED CELL POLYURETHANE FOAM OR FIRE RATED SILICONE FOAM 1/2" CLEAR (TYP.) DUCT OR SOUND TRAP FIBERGLASS INSULATION 1.5 PCF MAX. 100% FILL ACOUSTICAL SEALANT STEEL BEAM ACOUSTICAL SEALANT WALL TYPE VARIES PER PLAN SCALE:16 WALL PENETRATION DETAILS 1-1/2" = 1'-0" ELEVATION SECTION DUCT PENETRATION ELEVATION SECTION BEAM PENETRATION SECTIONELEVATION PENETRATIONS OF ACOUSTICAL PARTITIONS BY DUCT, CONDUIT, CABLE, PIPES ETC. SHALL BE ACOUSTICALLY SEALED AS SHOWN. ANY GAP LARGER THAN 1/2" SHALL BE COVERED WITH GYPSUM BOARD, LAPPED A MINIMUM OF 2" AND SCREWED BEFORE USING ACOUSTICAL SEALANT. CLOSED CELL POLYURETHANE FOAM OR FIRE RATED SILICONE FOAM 1/2" CLEAR (TYP.) DUCT OR SOUND TRAP FIBERGLASS INSULATION 1.5 PCF MAX. 100% FILL FIBERGLASS INSULATION 1.5 PCF MAX. (100% FILL) STRUCT DECK ACOUSTICAL SEALANT STEEL BEAM ACOUSTICAL SEALANT WALL TYPE VARIES PER PLAN SCALE:2 LOW WALL DETAILS 1 1/2" = 1'-0" 3/16"STEEL PLATE 6" x 6" x 5/8" S.M.S. #10 @ 2'-0" O.C. & 2" FROM EACH END 600S 137-33 MTL STUDS @ 1'-4" O.C. STEEL TUBE 2"x 2"x 3/16" @ 4'-0" O.C. STUDS EACH SIDE OF TUBE STEEL PLAN VIEW SECTION VIEW (2) 3/8" DIA SIMPSON TITEM HD SCREWS x 3 1/4" EMBED S.M.S. #10 @ 2'-0" O.C. & 2" FROM EACH END OF STUDS EDGE OF TRACK BELOW STEEL TUBE 2"x 2"x 3/16" @ 4'-0" O.C. (2) 3/8" DIA SIMPSON TITEN HD SCREWS x 3 1/4" EMBED 3/16" 4' - 0 " M A X . 6x6 STEEL PLATE 4" 2" 2" CONT. 6" TRACK AT TOP & BOTTOM (MATCH GA. OF STUDS) STUDS EACH SIDE OF TUBE STEEL LOW HEIGHT PARTITION (SEE DETAIL 2 ON THIS SHEET) IN WALL 1-1/2" X 1-1/2" X 14" METAL BRACKET SUPPORTS WELDED TO STEEL TUBE SEE DETAIL 20 ON THIS SHEET SOLID SURFACE COUNTER EXISTING PARTITION LOW HEIGHT PARTITION SEE DETAIL 2 ON THIS SHEET IN WALL 1-1/2" X 1-1/2" X 1 4" METAL BRACKET SUPPORTS WELDED TO STEEL TUBE SOLID SURFACE COUNTER 12 COUNTER AT EXISTING WALL 11 COUNTER AT SERVICE COUNTER QUARRY TILE BASE TO MATCH EXISTING SEE DETAIL 20 ON THIS SHEET LOW HEIGHT PARTITION - SEE DETAIL 2 ON THIS SHEET SOLID SURFACE COUNTER 13 EDGE LID COUNTER AT SERVICE COUNTER QUARRY TILE BASE TO MATCH EXISTING SEE DETAIL 4 ON THIS SHEET SERVICE COUNTER QUARRY TILE BASE TO MATCH EXISTING SEE DETAIL 20 THIS SHEET GYP. BD. (PAINTED) OVER METAL FRAMING GYP. BD. (PAINTED) OVER METAL FRAMING EXISTING WALL TILE TO REMAIN SOLID SURFACE OVER 3 4" PLYWOOD STEEL ANGLE R 1/2" SCALE:20 COUNTER EDGE DETAIL 6" = 1'-0" R 1/2" LED ROPE LIGHT (SEE ELECTRICAL) SOLID SURFACE OVER 3 4" PLYWOOD SOLID SURFACE OVER 1-1/2" SOLID BLOCKING PANELING OVER GYP. BD. (SEE ELEVATION) LOW WALL FRAMING (SEE DETAIL2 THIS SHEET) GYP. BD. (PAINTED) SCALE:4 COUNTER EDGE DETAIL 6" = 1'-0" BOTTOM OF KITCHEN HOOD KITCHEN HOOD STAINLESS STEEL VERTICAL SIDE PANEL EXISTING METAL STUD PARTITION WITH 5/8" TYPE X GYP. BD. ON BOTH SIDES STAINLESS STEEL BACKSPLASH OVER GYP. BD. EXISTING QUARRY TILE WALL BASE STAINLESS STEEL BACKSPLASH TO FACE OF SOFFIT (SEE DETAIL 5 ON SHEET A401) SCALE:21 BACKSPLASH DETAIL 1-1/2" = 1'-0" SCALE:29 WALL ANCHORAGE TO STRUCTURE 3" = 1'-0" SCALE:28 WALL BACKING DETAIL 1" = 1'-0" SCALE:14 WALL BRACING TO STRUCTURE 3" = 1'-0" AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK A510 W S SCALE:21 TYPICAL ACOUSTICAL CEILING LAYOUT DETAILS VARIES CROSS RUNNER MAIN RUNNER TYPICAL 12 GA. VERTICAL HANGER WIRE @ 4'-0" EACH WAY WITH MINIMUM 3 TIGHT TURNS (WITHIN 1 1/2" DISTANCE) @ BOTH ENDS OF WIRE (SEE DETAIL 15 FOR ANCHORING TO DECK) (2) #12 S.M.S CONNECTING COMPRESSION STRUT TO T-BAR GRID COMPRESSION STRUT (SEE DETAIL 21I & 21J) OR OPTIONAL EMT TUBING PER SCHEDULE ABOVE 12 GA. BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN A DISTANCE OF 1 1/2" @ BOTH ENDS OF WIRE (TYPICAL). SEE DETAIL 15B, 15D & 15E FOR ANCHORING TO DECK SUSPENDED CEILING NOTES A SET OF FOUR SPLAY WIRES SHALL BE PROVIDED FOR EACH 96 S.F. OF TRIBUTARY AREA. FIRST SET OF SPLAY WIRES SHALL BE WITHIN 4"-0" FROM ANY WALL. PROVIDE COMPRESSION STRUT AT EACH SPLAY WIRE LOCATION. CROSS RUNNER SLOT END OF TUBE OR POST TO FIT OVER MAIN RUNNER SCALE:21A 3D VIEW OF CEILING 1" = 1'-0" 12 GA. VERT. HANGER WIRE SET TO CEILING GRID LEVEL PRIOR TO FASTENING TUBE 1.SUSPENDED CEILING SYSTEMS, ALSO KNOWN AS ACOUSTICAL CEILING SYSTEMS, ARE CEILING ASSEMBLIES USED TO SUPPORT ACOUSTICAL LAY-IN PANELS OR TILES. SUCH SYSTEMS SHALL COMPLY WITH SECTIONS 808 AND 2506 OF THE BUILDING CODE, INCLUDING SECTION 13.5.6 OF THE ASCE 7-05 STANDARD, ASTM C 635 AND CISCA - "GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT-HUNG SUSPENDED CEILING ASSEMBLIES", AS WELL AS TO COMPLY WITH ICC EVALUATION REPORT ESR-1222 2.CEILING AREAS EXCEEDING 144 SQ FT SHALL HAVE HORIZONTAL AND VERTICAL RESTRAINTS OF THE CEILING TO THE STRUCTURAL SYSTEM 3.CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. LUMINARIES, SPEAKERS, DUCTS AND GRILLS, CABLES, CABLE TRAYS, ELECTRICAL BOXES, AND CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. IN FIRE-RATED ASSEMBLIES, WHERE INDEPENDENT SUPPORT WIRES ARE USED, THEY SHALL BE DISTINGUISHABLE BY COLOR, TAGGING, OR OTHER EFFECTIVE MEANS FROM THOSE THAT ARE PART OF THE FIRE-RATED DESIGN 4.12 GA. (MIN) HANGER WIRES MAY BE USED FOR UP TO AND INCLUDING 4'-0" X 4'-0" GRID SPACING ALONG MAIN RUNNERS 5.PROVIDE 12 GA. HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN 8" FROM THE SUPPORT OR WITHIN 1/4 OF THE LENGTH OF THE END TEE, WHICHEVER IS LEAST, FOR THE PERIMETER OF THE CEILING AREA. END CONNECTIONS FOR RUNNERS WHICH ARE DESIGNED AND DETAILED TO RESIST THE APPLIED HORIZONTAL FORCES MAY BE USED IN LIEU OF THE 12 GA. HANGER WIRES 6.PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO MAIN HANGER SPACING. PROVIDE ADDITIONAL HANGERS, STRUTS, OR BRACES AS REQUIRED AT ALL CEILING BREAKS, SOFFITS OR DISCONTINUOUS AREAS. HANGER WIRES THAT ARE MORE THAN 1 IN 6 OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES 7.CEILING GRID MEMBERS MAY BE ATTACHED TO NOT MORE THAN 2 ADJACENT WALLS. CEILING GRID MEMBERS SHOULD BE AT LEAST 3/4 INCH FREE OF OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE AND A MINIMUM OF 3/4 INCH CLEAR OF WALL 8.AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN THE RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A 16 GA. WIRE WITH A POSITIVE MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER IS 12" OR LESS, THIS INTERLOCK IS NOT REQUIRED 9.PROVIDE SETS OF FOUR 12 GA. SPLAYED BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER 10.THE SLOPE OF THESE WIRES SHOULD NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND SHOULD BE TAUT WITHOUT CAUSING THE CEILING TO LIFT. SPLICES IN BRACING WIRES ARE NOT TO BE PERMITTED WITHOUT SPECIAL OSHPD APPROVAL 11.FASTEN HANGER WIRES WITH NOT LESS THAN THREE TIGHT TURNS. FASTEN BRACING WIRES WITH FOUR TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A DISTANCE OF 1-1/2 INCHES. HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE WIRE ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE FORCES ACTING ON THE WIRE 12.SEPARATE ALL CEILING HANGING AND BRACING WIRES AT LEAST 6 INCHES FROM ALL UN-BRACED DUCTS, PIPES, CONDUITS, ETC. IT IS ACCEPTABLE TO ATTACH LIGHTWEIGHT ITEMS, SUCH AS SINGLE ELECTRICAL CONDUIT NOT EXCEEDING 3/4" NOMINAL DIAMETER, TO HANGER WIRES USING CONNECTORS ACCEPTABLE TO OSHPD 13.WHEN DRILLED-IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN REINFORCED CONCRETE FOR HANGER WIRES, 1 OUT OF 10 MUST BE FIELD TESTED FOR 200 POUNDS OF TENSION. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES, 1 OUT OF 2 MUST BE FIELD-TESTED FOR 440 POUNDS OF TENSION. SHOT-IN ANCHORS IN CONCRETE ARE NOT PERMITTED FOR BRACING WIRES. IF ANY SHOT-IN OR DRILLED-IN ANCHOR FAILS, ALL ADJACENT ANCHORS MUST BE TESTED 14.ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES 15.ALL FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING LESS THAN 56 POUNDS MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY-DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO 12 GA. SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE. ALL 4 FT. X 4 FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACH CORNER 16.ALL FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING 56 POUNDS OR MORE MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN 4 TAUT 12 GA. WIRES EACH ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED 17.THE 4 TAUT 12 GA. WIRES INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE UNIT 18.SUPPORT SURFACE-MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICH SURROUND THE CEILING RUNNER AND WHICH ARE EACH SUPPORTED FROM THE STRUCTURE ABOVE BY A 12 GA. WIRE. SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT ACCEPTABLE 19.PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES ARE 8 FEET OR LONGER 20.SUPPORT PENDANT-MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE FIXTURES. (SEE ALSO NOTE 10 ABOVE) 21.ALL CEILING SUSPENSION SYSTEM COMPONENTS SHALL BE "HEAVY DUTY" TYPE WITH COMPONENTS PARTS AS LISTED BELOW 22.ACOUSTICAL CEILING GRID EXPANSION JOINTS REQUIRED FOR ANY CEILING AREAS OVER 2,500 S.F. OR 100'-0" IN ANY DIRECTION PER CODE. 23.STABILIZER BARS, CROSS TEES OR OTHER SUITABLE MEANS TO PREVENT SPREADING SHALL BE PROVIDED WITHIN 8" OF EACH WALL 24.SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS 25.CEILING CLOUDS: PROVIDE HANGING WIRES, BRACE WIRES AND COMPRESSION STRUT AS DETAILED. IN ADDITION PROVIDE BRACE WIRES AND COMPRESSION STRUTS AT EACH CORNER, REGARDLESS OF THE TYPE OF CLOUD ESR-1222 400S137-33 (20 GA.) 250T125-33 (20 GA.) 250T125-33 (20 GA.) OPTIONAL ELECTRICAL METALLIC TUBING (EMT) SCHEDULE HEIGHT* EMT OPTION METAL STUD OPTION UP TO 7'-0" UP TO 6'-0" UP TO 5'-0" UP TO 10'-0"400S137-33 (20 GA.) 1-1/4" EMT 1" EMT 3/4" EMT - ANY STRUT HEIGHT GREATER THAN 20'-0" WILL REQUIRE ENGINEERING CALCULATIONS. CONTRACTOR IS RESPONSIBLE TO CONTRACT A LICENSED STRUCTURAL ENGINEER AND SUBMIT THE CALCULATIONS *DISTANCE BETWEEN CEILING AND STRUCTURE ABOVE. UP TO 20'-0"400S162-43 (18 GA.)- NOTE: ALL MAIN AND CROSS RUNNERS TO BE HEAVY DUTY MEMBERS SCALE:21C 2'-0" X 2'-0" GRID 1/4" = 1'-0"SCALE:21D 2'-0" X 4'-0" GRID OR 2'-0" X 5'-0" GRID 1/4" = 1'-0" SCALE:21B TYPICAL CEILING GRID LAYOUT PLAN 1/4" = 1'-0"SCALE:21I COMPRESSION POST & WIRE (ACT) 3" = 1'-0"SCALE:21E GRID ATTACHMENT (ACT FREE SIDE) 3" = 1'-0" SCALE:21F GRID ATTACHMENT (ACT FIXED SIDE) 3" = 1'-0"SCALE:21H LIGHT FIXTURE SUPPORT (ACT & GYP. BD.) 3" = 1'-0" SCALE:15F COMPRESSION STRUT TO STRUCTURE 3" = 1'-0"SCALE:15D BRACE WIRE TO STRUCTURE 3" = 1'-0"SCALE:15B HANGER WIRE TO STRUCTURE 3" = 1'-0" SCALE:15E COMPRESSION STRUT TO STRUCTURE 3" = 1'-0"SCALE:15C BRACE WIRE TO STRUCTURE 3" = 1'-0"SCALE:15A HANGER WIRE TO STRUCTURE 3" = 1'-0"(METAL DECK)(METAL DECK)(METAL DECK) (CONCRETE)(CONCRETE)(CONCRETE) SCALE:21K GRID EXPANSION JOINT (ACT) N.T.S. SCALE:21J COMPRESSION POST & WIRE (GYP. BD.) 3" = 1'-0"SCALE:21G GRID ATTACHMENT (GYP. BD.) 3" = 1'-0" SCALE:21H EXPANSION JOINT (GYP. BD.) 3" = 1'-0" SCALE:20 TYP. SUSPENDED WALL DETAILS 3" = 1'-0" SCALE:20A STUDS PERPENDICULAR TO FLUTES (CONCRETE) 3" = 1'-0" SCALE:20B STUDS PARALLEL TO FLUTES (CONCRETE) 3" = 1'-0" SCALE:15G ATTACHED TO STUDS 1" = 1'-0"SCALE:15H ATTACHED BETWEEN STUDS 1" = 1'-0" SCALE:15 ATTACHMENT TO DECK STRUCTURE VARIESSCALE:25 PENDANT FIXT. BRACE 3/4" = 1'-0" UNBRACED BRACED @ MIDSPAN CEILING JOIST SPAN TABLE SCALE:29 CEILING FRAMING(NON-LOAD BEARING) VARIES A515 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK A516 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK MECHANICAL LEAD SHEET M-00 MECHANICAL SHEET INDEX SHEET #SHEET NAME M-00 MECHANICAL LEAD SHEET M-01 MECHANICAL FLOOR PLAN 2022 CALIFORNIA BUILDING CODE. 2022 CALIFORNIA MECHANICAL CODE. 2022 CALIFORNIA PLUMBING CODE. 2022 CALIFORNIA ENERGY CODE. 2022 CALIFORNIA ELECTRICAL CODE. 2022 CALIFORNIA FIRE CODE. 2022 CALIFORNIA GREEN BUILDING CODE WITH ALL AHJ AMENDMENTS. APPLICABLE CODE GRILLES AND REGISTERS SCHEDULE MANUFACTURER MODEL FINISH DESCRIPTION VOLUME DAMPER REMARKS PRICE INDUSTRIES AMCD AS PER ARCH/ID SQUARE FACE DIFFUSER YES NICK SIZE PER PLANS. NOTES: -INSTALL LINEAR DIFFUSER/GRILL WITH FACTORY PROVIDED PLENUM. -WHERE DIFFUSER/GRILL MANUFACTURED WITH RECTANGULAR OUTLET/INLET, INSTALL DUCT TRANSITION TO ROUND. -FINISHES SHALL BE PER ARCH./ID PLANS. -SPECIFIED DIFFUSER/GRILL CAN BE SUBSTITUTE WITH ANY APPROVED EQUAL. AIR BALANCE SCHEDULE UNIT OUTSIDE AIR EXHAUST AIR NOTES KEF-1 --INTERLOCKED WITH MAU SCALE:1 CEILING REGISTER/DIFFUSER N.T.S M-02 GREASE HOOD DETAILS DUCT INSTALLATION & INSULATION SHALL COMPLY WITH 2022 T24 AND AS BELOW (REFER TO MANDATORY MEASURES ON SHEET M-03 FOR ADDITIONAL REQUIREMENTS): -DUCT LOCATED WITHIN DROP CEILING OR IN BETWEEN STRUCTURAL JOISTS SHALL HAVE A 1" INSULATION NOT LESS THAN R4.2 VALUE TO PREVENT CONDENSATION. -DUCT LOCATED IN UNCONDITIONED SPACE SHALL HAVE A MINIMUM OF 2" INSULATION AND NOT LESS THAN R8 VALUE. -DUCT LOCATED WITHIN VENTILATED ROOF ATTIC SHALL HAVE A MINIMUM OF 2" INSULATION AND NOT LESS THAN R8 VALUE. -EXPOSED DUCT SHALL BE SPIRAL PAINTED PER ARCH. PLANS. EXPOSED DUCT WORK TO CONDITIONED AREA'S SHALL BE PERMITTED TO BE INSTALLED WITHOUT INSULATION. -DUCT PLENUMS SHALL BE LINED WITH 1" INSULATION. -DUCT SUPPORT SHALL CONFIRM TO MANUFACTURER RECOMMENDATIONS, CMC & SMACNA GUIDELINES. -DUCT LOCATED WITHIN DROP CEILING OR STRUCTURAL JOIST SHALL BE PERMITTED TO HAVE THE LAST 5' OF RUN TO THE DIFFUSER OF FLEX DUCT THAT COMPLIES WITH CMC. -DUCT EXPOSED TO WEATHER SHALL HAVE A MINIMUM OF 2" INSULATION AND WRAPPED WITH APPROVED WEATHER PROTECTION MATERIAL SUCH AS ALUMINUM WRAP THAT IS ABLE TO PROTECT IT FROM WATER, SUN LIGHT AND UV LIGHT. DUCT CONSTRUCTION AND MATERIAL SCHEDULE 2,200 2,400 M-03 PRICE INDUSTRIES CVD AS PER ARCH/ID RESTROOM DIFFUSER YES NICK SIZE PER PLANS. PRICE INDUSTRIES 10FF AS PER ARCH/ID PERFORATED RETURN YES NICK SIZE PER PLANS. PRICE INDUSTRIES 10FF AS PER ARCH/ID FILTERED RETURN NO NICK SIZE PER PLANS. SCALE:3 GREASE HOOD 6" OVERHANG HORIZONTAL DETAIL N.T.S M-04 EXPOSED CEILING SCALE:2 DUCT MOUNT ROUND DIFFUSER DETAIL N.T.S KEF-2 -- GREASE HOOD DETAILS GREASE HOOD DETAILS M-05 GREASE HOOD DETAILS M-06 GREASE HOOD DETAILS M-07 GREASE HOOD DETAILS M-08 GREASE HOOD DETAILS M-09 GREASE HOOD DETAILS M-10 GREASE HOOD DETAILS M-11 PRICE INDUSTRIES RCDE AS PER ARCH/ID ROUND DIFFUSER YES NICK SIZE PER PLANS. ENERGY COMPLIANCE FORMS SCALE:4 GREASE DUCT ACCESS PANEL SPEC'S N.T.S MAU-1 4,600 -- INTERLOCKED WITH MAU INTERLOCKED WITH KEF'S TOTAL 4,600 4,600 SPACE IS BALANCED M-12 ENERGY COMPLIANCE FORMS S KITCHENSUPPORT KITCHEN SERVICE COUNTER WH GREASE HOOD UTILITY CABINET SUITE FC2 BELOW INDICATED BY SOLID HATCH (E) ROOF TOP ENCLOSURE WALL (E) HVAC UNIT (N.I.C.) (E) HVAC UNIT (N.I.C.) MECHANICAL FLOOR PLAN M-01 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK SCALE:1 MECHANICAL FLOOR PLAN 1/4"=1'-0"SCALE:2 MECHANICAL ROOF PLAN 1/4"=1'-0" 1500500 FLOW RATE (CFM) 1000 0.00 0 0.50 PR E S S U R E D R O P ( i n . H 2 0 ) PRESSURE DROP VS. FLOW RATE FR A C T I O N A L E F F I C I E N C Y ( % ) 0 0.1 20 40 1.0 PARTICLE DIAMETER (UM) 10.0 EFFICIENCY VS. PARTICLE DIAMETER 60 80 100 1.00 1.50 2.00 2.50 3.00 3.50 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-02 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-03 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK ” ” SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-04 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-05 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK PRESSURE OVERFLOWSWITCH To buildingdrain Field Wiredand Piped From buildingwater supplyNormally closed valve B W Roof line R WB R SWITCH AE Normally open valve InternalWaterSolenoid TIMER 15 A1 18 A2 16 P SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-06 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK ɸ SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-07 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-08 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-09 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK CUSTOMER APPROVAL TO MANUFACTURE: SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-10 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK ENERGY COMPLIANCE FORMS M-11 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK ENERGY COMPLIANCE FORMS M-12 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK PLUMBING GENERAL NOTES 1.PLUMBING WORK SHALL COMPLY WITH 2022 CALIFORNIA BUILDING CODES AND AHJ AMENDMENTS. 2.PLUMBING EQUIPMENT SHALL BE APPROVED AND TESTED UNDER APPROVED AGENCY FOR THE AHJ. 3.EACH HORIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH A CLEANOUT AT ITS UPPER TERMINAL, AND EACH RUN OF PIPING, THAT IS MORE THAN 100 FEET IN TOTAL DEVELOPED LENGTH, SHALL BE PROVIDED WITH A CLEANOUT FOR EACH 100 FEET, OR FRACTION THEREOF, IN LENGTH OF SUCH PIPING. AN ADDITIONAL CLEANOUT SHALL BE PROVIDED IN A DRAINAGE LINE FOR EACH AGGREGATE HORIZONTAL CHANGE IN DIRECTION EXCEEDING 135 DEGREES. A CLEANOUT SHALL BE INSTALLED ABOVE KITCHEN SINK AND LAVATORY CONNECTION FITTING, SERVING EACH FIXTURE. 4.SANITARY SEWER LINE TO SLOPE @ 2% UNLESS NOTED OTHERWISE. 5.CONTRACTOR TO VERIFY POINT OF CONNECTION PRIOR ANY INSTALLATION. 6.ALL VALVES AND FITTING TO SAME SIZE AS PIPE SIZE. 7.FLOOR DRAINS SHALL HAVE A TRAP PRIMER. 8.UNIONS SHALL BE PROVIDED PRIOR TO ANY EQUIPMENT CONNECTION. 9.THE USE OF CPVC PIPING SHALL COMPLY WITH 2022 CPC 604.1.1. 10.THE USE OF PEX PIPING SHALL COMPLY WITH 2022 CPC 604.1.1. 11.HOT WATER PIPING INSULATION SHALL BE PER 2022 CALIFORNIA PLUMBING CODE 609.11.2: "HOT WATER PIPE INSULATION SHALL BE PER BELOW SCHEDULE. EXCEPTIONS: -PIPING THAT PENETRATES FRAMING MEMBERS SHALL NOT BE REQUIRED TO HAVE PIPE INSULATION FOR THE DISTANCE OF THE FRAMING PENETRATION. -HOT WATER PIPING BETWEEN THE FIXTURE CONTROL VALVE OR SUPPLY STOP AND THE FIXTURE OR APPLIANCE SHALL NOT BE REQUIRED TO BE INSULATED. 14.SLEEVES SHALL BE PROVIDED FOR PIPING PASSING THRU MASONRY OR CONCRETE FLOORS/WALLS. 15.PLUMBING FIXTURE SHALL MEET 2022 CALIFORNIA PLUMBING CODE REQUIREMENTS PER CHAPTER 4 AND CALIFORNIA GREEN CODE FIXTURE FLOW. 16.DOMESTIC WATER LINE SHALL BE DISINFECTED PER 2022 CPC 609.9. 17.WET VENT SHALL NOT EXCEED 6' IN LENGTH. 18.WATER PIPES AND FITTINGS WITH A LEAD CONTENT WHICH EXCEEDS 0.25% SHALL BE PROHIBITED IN SYSTEMS CONVEYING POTABLE WATER. (CPC604.2) 19.CONTRACTOR SHALL FIELD VERIFY UTILITIES POINT OF CONNECTION AND COORDINATE AT SITE AS NEEDED. PLUMBING LEGENED AND ABBREVIATIONS SYMBOL ABBREVIATIO DESCRIPTION CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER HWR DOMESTIC HOT WATER RETURN SS SANITARY SEWER SS BG SANITARY SEWER BELOW GROUND SD STORM DRAIN SD BG STORM DRAIN BELOW GROUND V PLUMBING VENTS GAS STANDARD PRESSURE GAS MPG MEDIUM PRESSURE GAS PCD PRIMARY CONDENSATE SCD SECONDERY CONDENSATE HB HOSE BIB DN PIPE DOWN UP PIPE UP DS DOWNSPOUT P.O.C POINT OF CONNECTION RD ROOF DRAIN OD OVERFLOW DRAIN AD AREA DRAIN FD FLOOR DRAIN ED EMERGENCY DRAIN TD TRENCH DRAIN FS FLOOR SINK WCO WALL CLEAN OUT YCO YARD CLEAN OUT COTG CLEAN OUT TO GRADE FCO FLOOR CLEAN OUT SR SUD RELIEF IRR IRRIGATION ABV ABOVE BLW BELOW 2022 CALIFORNIA ENERGY CODE TABLE 120.3-A PIPE INSUALTION THICKNES IN INCHES OR R VALUE FLUID TEMPRETURE INSULATION CONDUCTIVITY NOMINAL PIPE SIZE BTU.in/(h X FT² X °F)MEAN RATING TEMPRETURE F <1 1 TO <1 1/2 1 1/2 TO <4 4 TO <8 >8 105-140 F 0.22-0.28 100 1 1.5 1.5 1.5 1.5 R-7.7 R-12.5 R-11 R-9 R-8 PLUMBING SHEET INDEX SHEET #SHEET NAME P-00 PLUMBING LEAD SHEET P-01 PLUMBING FLOOR PLAN PLUMBING FIXTURES MAX FLOW RATE HAND SINK PLUMBING FIXTURE MAX FLOW RATE 1.2 GPM @ 60 psi PUBLIC LAVATORIES 0.5 GPM @ 60 psi METERING FAUCET 0.25 GPC SHOWER HEAD 1.8 GPM @ 80 PSI WATER CLOSET 1.25 GPF URINAL 0.125 GALLONS KITCHEN FAUCET 1.8 GPM @ 60 PSI THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY CODE WITH ALL AHJ AMENDMENT. PIPE MATERIAL SCHEDULE DOMESTIC WATER (2 ) B A N D NO - H U B CA S T I R O N SC H E D U L E 80 P V C TY P E L CO P P E R SC H E D U L E 4 0 BL A C K S T E E L CP V C PV C AB S NOTES INSIDE C & H WATER ABV FLOOR UNDER SLAB THRU SLAB OUTSIDE MUST BE SLEEVED, PVC USED FOR EXTERIOR BUILDING SUPPLY MUST BE SLEEVED, PVC USED FOR EXTERIOR BUILDING SUPPLY SS, VENT & SD RISERS THRU ALL FLOORS BELOW SLAB (UNDERGROUND) NO HUB CAST IRON, 2-BAN- NO HUB COUPLINGS PVC DWV (AS APPROVED PER AHJ) CONDENSATE ABV FLOOR AS APPROVED PER AHJ INDIRECT WASTE ABV FLOOR AS APPROVED PER AHJ SERVICE PIPE MATERIAL PLUMBING LEAD SHEET P-00 TY P E K CO P P E R GAS OUTSIDE OR EXPOSED INSIDE THE BUILDING SC H E D U L E 4 0 GA L V N I Z E D ST E E L PROVIDE DOUBLE WALL PIPING WITH VENT IF INSTALLED BLW SLAB AS APPROVED PER AHJ *INSTALLATION OF CPVC SHALL BE PER 2022 CPC 604.1.1 & 609.9 *INSTALLATION OF GAS PIPING SHALL BE PER 2022 CPC 1210.0. *ALL CPVC PIPING SHALL COMPLY WITH CHAPTER 15 FIRESTOP PROTECTION WHERE NEEDED. *USE CORZAN SCHEDULE 80 FOR WATER PIPES SIZE OF 212" AND LARGER. *USE FLOW GUARD GOLD CPVC 41 FOR WATER PIPES SIZES OF 2" AND SMALLER. *ALL EXPOSED GAS PIPING SHALL BE PROTECTED AGAINST CORRSION BY COATING OR WRAPPING WITH AN INERT MATERIAL APPROVED FOR SUCH APPLICATION. PER 2022CPC SECTION 1208.5.6 & 1210.1.3. *PVC SCHEDULE 40 FOR DCW UNDER SLAB ONLY, NOT ALLOWED WITHIN THE BUILDING. *COPPER TYPE L: FIRST 10' OF PIPE CONNECTION TO WATER HEATER OR WHEN PIPE EXPOSED OUTDOOR AND ROOF. AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK WATER HEATER CALC'S DEMAND CALC'S: (1) KITCHEN SINK (3 COMP)@ 45 GPH = 45 (1) KITCHEN SINK (PREP)@ 15 GPH = 15 (1) MOB SINKS @ 15 GPH = 15 (2) HAND SINK @ 05 GPH = 10 TOTAL REQIURED = 85 GPH (E) RHEEM GAS TANK WATER HEATER (GNU82-252) 151.3 GPH @ 60°F TOTAL OF SUPPLY HOT WATER . SCALE:3 FLOOR CLEAN OUT N.T.SSCALE:2 WALL CLEAN OUT N.T.SSCALE:1 PIPE PENETRATION THRU INTERIOR WALL N.T.S DESCRIPTION VENTWASTE ROUGH-IN SERVICES ITEM FIXTURE GASHOTCOLD WATERWATER TOTAL GAS DEMAND MODEL NUM.MARK PLUMBING FIXTURE SCHEDULE DESCRIPTION COLDVENTSS HOT PIPE SIZES KITCHEN SINK - 3 COMPKS-1 AS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 1.8 GPM @ 60 PSI FLOOR SINK - ZURN Z1901FS-1 2"2"12"-12" SQUARE FLOOR SINK, ACID RESISTANCE COAT, CAST IRON BODY MATERIAL. LIGHT DUTY & HEAL PROOF GRATE. INSTALL TRAP PRIMER. TRAP PRIMER PPP PR01-ULP500TP 12"-PPP PR01-ULP500 TRAP PRIMER, LOCATE UNDER THE SINK EXPOSED OR WITHIN AN ACCESS PANEL. LEAD FREE FLOW ACTIVATION.-- SERVICE SINK/MOB SINKSS-1 AS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 2.2 GPM @ 60 PSI NOTES: *NOTHING WITHIN THE SPEC'S ALLOW TO INSTALL ANY ITEM WITH DISCREPANCIES WITH LOCAL CODES AND AMENDMENTS. CONTRACTOR SHALL INFORM EOR FOR ANY POTENTIAL DISCREPANCY PRIOR ORDERING ANY FIXTURE. CONTRACTOR CAN SUBSTITUTE FIXTURES WITH ANY APPROVED EQUAL. OBTAIN OWNERSHIP APPROVAL PRIOR SUBMITTING TO EOR FOR REVIEW. *ALL INSTALLED FIXTURES AND EQUIPMENTS SHALL BE LISTED AND TESTED PER ONE OF THE APPROVED LISTING AGENCY TO THE AHJ. HAND SINK - ADAHS-1 AS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 1.2 GPM @ 60 PSI EXISTING TO REMAIN INDIRECT EXISTING TO REMAINAS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 1.8 GPM @ 60 PSIKITCHEN SINK - PREPKS-2 ICE MACHINEIM-1 AS SPECIFIED BY ARCH/DEVELOPER. SODA FOUNTAIN DRINKFD-1 AS SPECIFIED BY ARCH/DEVELOPER. EXISTING TO REMAIN INDIRECT (E) INDIRECT (E)12"- 12"- EXISTING TO REMAIN PLUMBING FIXTURES FLOW RATE MUST COMPLY WITH ALL CAL GREEN REQUIREMENT PER SECTION 5.303 FOR NON-RESIDENTIAL APPLICATIONS & CPC SECTION 407 TO 417 WH T FE FE KITCHENSUPPORT KITCHEN SERVICE COUNTER WH GREASE HOOD UTILITY CABINET PLUMBING FLOOR PLAN P-01 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA Consultant: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA 08/11/2025 1ST PLAN CHECK 09/12/2025 2ND PLAN CHECK SCALE:1 PLUMBING FLOOR PLAN 1/4"=1'-0" ITEM NO DESCRIPTION CW HW INDIRECT SS SS & V THE SHOPS AT SANTA ANITA FC-2 KITCHEN EQUIPMENTS - PLUMBING ROUGH IN SIZES NOTES: -REFER TO KITCHEN PLANS FOR THE FULL SCHEDULE. -SCHEDULE SHOWN FOR REFERENCE ONLY. MODEL NUMBER AND MANUFACTURER TO BE VERIFIED WITH ARCH. PLANS. -FOR PLUMBING ROUGH IN CONNECTION TO EQUIPMENTS DETAILS REFER TO ARCH. PLUMBING KEY NOTES: E;I67ING 3/8M%ING )I;78RE 72 %E &$RE)8//< 'I6&2NNE&7E' $N' RE3/$&E' $6 3ER $R&+ 3/$N6 IN 7+E 6$ME /2&$7I2N IN67$// NEW $NG/E 67236 7R$36 &2NNE&7I2N6 E;I67ING )/22R 6IN.)/22R 'R$IN 72 %E 3R27E&7E' IN 3/$&E '8RING &2N67R8&7I2N NEW  &2/' W$7ER /INE &2NNE&7 72 7+E M$IN W$7ER 628R&E WI7+IN 7+E 63$&E )IE/' 9ERI)< E;I67ING W$7ER +E$7ER R+E8M GN8 72 %E 3R27E&7E' IN 3/$&E )/22R 6IN. &2NNE&7  GW 9EN7 $N' 7$3 72 E;I67ING GRE$6E W$67E /INE 9EN7 WI7+IN 7+E 63$&E )IE/' 9ERI)<   &+INE6 R$NGE R  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+   +2/E R$NGE R  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 )R<ER )R  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 R$NGE R  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 RI&E &22.ER GR&  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ 62/EN2I' 9$/9E 69 WI7+ $&&E66 3$NE/ &2NNE&7E' 72 7+E +22' )IRE 6833RE66I2N 6<67EM &2NNE&7 72 E;I67ING GRE$6E W$67E /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+ I&E M$&+INE &2NNE&7  )I/7ERE' W$7ER  66 72 )/22R 6IN. 7+R28G+  $IR G$3 IN67$// %)3 )28N7$IN 'RIN. 62'$ 'I63EN6ER  &2NNE&7  )I/7ERE' W$7ER  66 72 )/22R 6IN. 7+R28G+  $IR G$3 IN67$// %)3 NEW +$N' 6IN. IN67$// &W+W $N'  66 9EN7 &2NNE&7 7+E 3/8M%ING /INE6 72 E;I67ING 6<67EM 9I)  PLUMBING GENERAL NOTES: &2N7R$&72R 6+$// 9ERI)< E;I67ING 87I/I7< /INE6 3RI2R $N< %I' &2N7R$&72R 6+$// IN&/8'E IN +I6 %I' 7+E &267 2) 7REN&+ING E;&$9$7I2N %E''ING /2&$7ING 87I/I7< /INE6 8N'ERGR28N' $N' 'EM2/I6+ING E;I67ING 3/8M%ING )I;78RE6 I) $N< R8N 66 /INE6 $7 $ 6/23E 2)   I) N27 3266I%/E N27I)< $R&+E2R &2N7R$&72R 72 &22R'IN$7E WI7+ 2WNER RE3 G& )2R $N< 6ER9I&E IN7ERR837I2N $N' 6+$// MINIMI=E '2WN7IME &2N7R$&72R 6+$// &/E$N 6I7E E9ER<'$< $N' 'I6&$R' 7+E 'E%RI6 IN $33R23RI$7E M$NNER 2876I'E 7+E 6I7E $// +W +WR 3I3E6 6+$// %E IN68/$7E' 3ER  &$/I)2RNI$ ENERG< &2'E 7  &2N7R$&72R 6+$// 3R29I'E NEW )I;78RE6 6833/< 67236 W+$ $N' $N< 3/8M%ING )I;78RE $&&E662R<  E &2N'EN6$7E /INE 6+$// %E 3R27E&7E' IN 3/$&E RE3$IR $6 NEE'E' $N' .EE3 $6 +IG+ $6 3266I%/E #  6/23E &22R'IN$7E 2N 6I7E $N' E;7EN' 7+E E /INE 72 7+E NEW /$9 7ERMIN$7E 72 7+E 7$I/ 3IE&E 2) /$9$72R< &2N7R$&72R 6+$// &$3 $N< E 3/8M%ING 3I3E6 IN )/22R6 W$//6 $N' &EI/ING 7+$7 6ER9E E 3/8M%ING )I;78RE6 %EING REM29E'RE/2&$7E' &2N7R$&72R 6+$// W$/. 7+E 6I7E 3RI2R %I''ING 7+E -2% $N' 6+$// IN&/8'E IN %I' 7+E &267 2) E;7EN'ING M2'I)<ING $N' 83GR$'ING 3/8M%ING /INE6 72 6ER9E 7+E NEW /$<287 $N< 3/8M%ING 3I3E /$RGER 7+$N W+$7 6+2WN 2N 3/$N6 6+$// %E $&&E37$%/E I) 6M$//ER &2N7R$&72R 6+$// RE3/$&E 72 M$7&+ 6I=E6 IN'I&$7E' 2N 3/$N6 &2N7R$&72R 6+$// &22R'IN$7E WI7+ ME&+$NI&$/ &2N7R$&72R 72 RE/2&$7E $N< 3/8M%ING 9EN76 WI7+IN  2) 2876I'E $IR IN7$.E6 IN67$// &/E$N 2876 E9ER<  2R &+$NGE 2) 'IRE&7I2N $// )I;78RE 6+$// +$9E $ W$// &/E$N 287 WI7+IN 7+E W$// %E+IN' I7 FW STOCK POT RANGE N/AN/AN/A COMMERCIAL GAS RICE COOKER N/A N/AN/AN/A N/A 1" N/A1" FLOOR MOUNTED MOP SINK STAINLESS STEEL PREP SINK WITH DRAIN BOARD FRYER ICE MACHINE SODA DISPENSER (POST MIX,DROP-IN) GAS N/A N/A N/AN/A N/A 70" THREE HOLE RANGE N/AN/A N/A 40" CHINESE RANGE ICE STORAGE BIN STAINLESS STEEL HAND SINK THREE COMPARTMENT SINK WITH TWO DRAINBOARD N/A N/A N/A N/A N/A N/A (E) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 2" 2" N/A 1" N/A N/A N/A N/A N/A 114" 2" 2" 3 4" 1" (E)N/A N/A (E) (E)(E) N/A N/A N/A N/A(E)(E) (E)(E) 12" N/A(E)(E) N/A 12" 1" TO FS PER CPC WITH FD ADJ. TO IT NOTES NEW SINK PER NOTE 15 E0.0 ELECTRICAL SYMBOLS, NOTES AND SHEET INDEX AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA MWQ ENGINEERING MECHANICAL, ELECTRICAL, PLUMBING AND ENERGY ANALYSIS 562.413.9495 INFO@MWQENG.COM 09/02/2025 2ND PLAN CHECK OS ELECTRICAL LEGEND C J S 3 door f A GFCI AFCI WP OC OC OSD d EX Jazayeri E1.0 POWER LAYOUT & ONE-LINE AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT FC2 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA MWQ ENGINEERING MECHANICAL, ELECTRICAL, PLUMBING AND ENERGY ANALYSIS 562.413.9495 INFO@MWQENG.COM KITCHEN SUPPORT KITCHEN SERVICE COUNTER T FE GFCI FE POWER LAYOUT SCALE: 1/2" = 1'-0" J ROOF PLAN POWER LAYOUT SCALE: 1/2" = 1'-0" KEF-2 KEF-1 MAU-1 E2.0 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE SANTA ANITA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 SANTA ANITA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT FC2 Consultant: Seal: 250601 Sheet Title Sheet # Client: REVISIONDATEDELTA MWQ ENGINEERING MECHANICAL, ELECTRICAL, PLUMBING AND ENERGY ANALYSIS 562.413.9495 INFO@MWQENG.COM ROOF PLAN POWER LAYOUT 208/120V 3P,4W 400A,MAIN A TAP TO EXISTING PROVISION TO MALL (EXISTING) ELECTRICAL ONE LINE DIAGRAM TRANSFORMER 480V TO 208/120V 112.5KVA (EXISTING) PANELSCHEDULES T SERVICE COUNTER KITCHEN KITCHEN SUPPORT FE J J GFCI GFCI GFCI GFCI GFCI GFCI GFCI FE 6'- 8 " CE N T E R L I N E O F S I N K 3'- 6 " CE N T E R L I N E O F S I N K 2'- 8 " 1' - 7 " CE N T E R L I N E OF E Q U I P M E N T 2' - 4 " CE N T E R L I N E OF E Q U I P M E N T 2'- 2 " CE N T E R L I N E OF E Q U I P M E N T 11'-1" MILLWORK (VERIFY DIMENSIONS IN FIELD WITH S.S. TABLE BEHIND)4" 1'- 1 0 " CE N T E R L I N E OF E Q U I P M E N T 5'- 2 " CE N T E R L I N E O F E Q U I P M E N T 22.42 2'- 0 " MI L L W O R K 11.40 11.40 11.40 11.40 11.40 11.40 22.41 22.43 22.44 11.406.22 5.72 11.40 11.40 11.40 11.40 11.40 11.40 11.40 11.40 11.40 4' - 1 " CE N T E R L I N E O F E Q U I P M E N T 3' - 8 " CL E A R 17'-10" MILLWORK 1 1A 12 3 3 4 5 6 7 9 10 11 2 13 14 15 16 17 18 19 20 21 22 2'-0" MIN. CLEAR 4'-5" MILLWORK 13'-10" PREFABRICATED SERVICE COUNTER 3' - 4 " SE R V I C E C O U N T E R 23.38 23 24 25 26 27 2727 27 8.05 S S S GYP. BD. +14'-9" GYP. BD. +11'-9" GYP. BD. +12'-7" 9.29 ALIGN 9.29 6'-0" INSIDE FACE OF SOFFIT (COORDINATE WITH HOOD) 5' - 1 " CE N T E R L I N E O F F L U E 9'- 6 " CE N T E R L I N E O F F L U E 11 1/2" 11 1/2" 23.38 28 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . TAG Project Number: 400 S. BALDWIN AVENUE ARCADIA, CALIFORNIA 91007 PHONE: (626) 617-4556 THE SHOPS AT SANTA ANITA 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 400 S. BALDWIN AVENUE SUITE FC2 ARCADIA, CA 91007 THE SHOPS AT SANTA ANITA FOOD COURT TATAYPA PERUVIAN KITCHEN Consultant: Seal: 08/11/2025 1ST PLAN CHECK 250601 Sheet Title & Number RENEWAL DATE RCHITE C T DESNECIL A A L I F O R NIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 Client: REVISIONDATEDELTA 09/12/2025 2ND PLAN CHECK 09/12/2025 HEALTH CORRECTIONS 09/29/2025 3RD PLAN CHECK A101 SCALE:16 PROPOSED FLOOR PLAN 1/2" = 1'-0" FLOOR PLAN GENERAL NOTES 1.CONTRACTOR SHALL VERIFY THAT ALL EXISTING DOOR FORCES (OPENING & CLOSING) MEET THE CURRENT BUILDING CODE REQUIREMENTS 2.ALL DOORS SHALL BE SELF CLOSING NORTH PROPOSED KEY NOTES SCALE:26 PROPOSED REFLECTED CEILING PLAN 1/2" = 1'-0" NORTH SCALE: 1/2"=1'-0" 0'2'1'4' SCALE: 1/2"=1'-0" 0'2'1'4' PROPOSED FLOOR PLAN & REFLECTED CEILING PLAN #DESCRIPTION DETAIL 1.FOR PLAN SYMBOL LEGEND AND ADDITIONAL NOTES & ABBREVIATIONS SEE SHEET G201. 2.PROVIDE SEISMIC BRACING, AS REQUIRED BY CODE AND INDICATED ON DRAWINGS, FOR ALL CEILING FINISHES, PLUMBING, FIRE SPRINKLER, MECHANICAL AND ELECTRICAL SYSTEMS. 3.EXIT SIGNS, WHERE NOTED, SHALL BE WORDED "EXIT" IN LETTERS SIX INCHES (6") HIGH. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES AND PROVIDED WITH AN EMERGENCY ELECTRICAL SYSTEM FROM STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON-SITE GENERATOR SET TO INSURE CONTINUED ILLUMINATION FOR AT LEAST 90 MINUTES IN CASE OF PRIMARY POWER LOSS. 4.INTERNALLY ILLUMINATED EXIT SIGNS - ELECTRICALLY POWERED, SELF-LUMINOUS AND PHOTOLUMINESCENT EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND (CBC) CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. 5.ADDITIONAL DIRECTIONAL EXIT SIGNAGE MAY BE REQUIRED BY THE GOVERNING AGENCY HAVING JURISDICTION OVER THE PROJECT AT THE TIME OF FINAL INSPECTION. RCP GENERAL NOTES 5 A401 10 A401 12 A401 17 A401 22 A401 23 A401 24 A401 25 A401 11 A401 25 A401 11 A401 DEMOLITION LEGEND EXISTING WALL TO REMAIN FIRE SPRINKLER (RE-CONFIGURE AS REQUIRED TO ACCOMMODATE NEW WORK) (N) MECHANICAL REGISTER (N) LIGHT FIXTURE (E) SUSPENDED GYP. BD. CEILING & GRID BY USG TO REMAIN (UL TYPE FC-CB, CLASS A, FLAME SPREAD RATING: 25 OR LESS & SMOKE DEVELOPMENT RATING: 50 OR LESS) (E) MECHANICAL GRILLE TO REMAIN (E) LIGHT FIXTURE TO REMAIN (E) ILLUMINATED EXIT SIGN TO REMAIN (E) CEILING ACCESS PANEL TO REMAIN EXISTING TO REMAIN PROPOSED S (E) SMOKE DETECTOR TO REMAIN (N) GYP. BD. CEILING / SOFFIT SEE SHEET A515 FOR SUSPENDED GYP. BD. CEILING DETAILS (E) GYP. BD. CEILING / SOFFIT TO REMAIN (N) ELECTRICAL OUTLETS (SEE ELECTRICAL DRAWINGS) 22.42 HAND SINK & FAUCET (SEE PLUMBING & KITCHEN CONSULTANT DRAWINGS) PREP SINK & FAUCET (SEE PLUMBING & KITCHEN CONSULTANT DRAWINGS) THREE COMPARTMENT SINK & FAUCET (SEE PLUMBING & KITCHEN CONSULTANT DRAWINGS) MOP SINK & FAUCET (SEE PLUMBING & KITCHEN CONSULTANT DRAWINGS) KITCHEN EQUIPMENT (SEE KITCHEN CONSULTANT DRAWINGS) GYP. BD. CEILING TO MATCH EXISTING 22.43 22.41 22.44 11.40 9.29 21 / A515 15 & 16 / ID101 26" X 20" STAINLESS STEEL WALL MOUNTED SPLASH GUARD (GSW MODEL# SP-S)5.72 COUNTER (SEE INTERIOR ELEVATIONS)6.22 26 A401 #DESCRIPTION MFR. TRUEREFRIGERATED DRAWERS (FOUR DRAWER) - 5" CASTORS1 MODEL # 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 TUC-67D-4-HC AMERICAN RANGESTOCK POT RANGE ARSP-18 AMERICAN RANGEFRYERAF-50HE GSWSTAINLESS STEEL WORK TABLE WT-EB3084 HOSHIZAKIICE MACHINE KM-350/520/660M_J(Z) HOSHIZAKIICE STORAGE BIN B-300SF CRATHCODOUBLE BOWL BUBBLER D25-4 -NOT USED - WARINGHEAVY DUTY ONE GALLON FOOD BLENDER CB15 TRUEREACH-IN REFRIGERATOR (SINGLE DOOR)T-19G-HC-FGD01 TRUEREACH-IN REFRIGERATOR (DOUBLE DOOR)T-49G-HC-FGD01 RINNAICOMMERCIAL GAS RICE COOKER RER-55ASN GSWSTAINLESS STEEL RICE COOKER STAND ES-RC3024 GSWSTAINLESS STEEL HAND SINK HS-1615W GSWSTAINLESS STEEL PREP SINK WITH DRAIN BOARD SE18181L GSWS.S. THREE COMPARTMENT SINK WITH TWO DRAIN BOARDS SH20243D GSWS.S. FLOOR MOUNTED MOP SINK SE2424FM CORNELIUSSODA DISPENSER (POST MIX, DROP-IN)2323 GENERAL70" THREE HOLE RANGE CHINESE WOK - MED GENERAL42" CHINESE RANGE CHINESE WOK - SM GENERALS.S. SERVICE COUNTER (19 ROUND PANS)- GSWS.S. SPLASH GUARD (WALL MOUNTED)SP-S2420 TRUEREFRIGERATED DRAWERS (TWO DRAWERS) - 5" CASTORS1A TUC-27D-2-HC EQUIPMENT LIST EQUIPMENT FOODSERVICE ACCESSORIES THREE COMPARTMENT SINK FAUCET ONE FAUCET SERVES ALL THREE SINKS (SEE CUT SHEET)23 25 26 27 28 5PR-8W12 STAINLESS STEEL MOP HANGER K-242 STAINLESS STEEL UTILITY SHELF K-246 METROWIRE SHELVING ANCHORED TO WALL (SEE NOTE BELOW)SUPER ERECTA CURTRONAIR CURTAIN 36" AIR-PRO ADVANCE TABCOMOP SINK FAUCET24 K-240 ADVANCE TABCO ADVANCE TABCO NOTES: 1) ALL EQUIPMENT SHALL BE ON 6" HIGH LEGS, COMMERCIAL CASTERS OR ON A 4" MASONRY CONTINUOUS COVED BASE 2) ANCHOR THE TOP SHELF OF EACH FOOD STORAGE WIRE RACK TO WALL STUDS USING FLEXIBLE STRAPS 3) ALL DOORS SHALL BE PROVIDED WITH CLOSERS (SELF CLOSING) ROOM NAME KITCHEN 101 FLOOR WALLS CEILING MT'L.HT. DOOR 11'-9" TRIMEXTERIORINTERIOR ROOM FINISH SCHEDULE GYP. BD. KITCHEN SUPPORT 102 12'-7"GYP. BD. SERVICE COUNTER 100 QT 14'-9"-GYP. BD. ABBREVIATIONS CT CERAMIC TILE PT PAINT QT QUARRY TILE 1. G.C. SHALL SUBMIT THE 3 SAMPLES OF ALL FINISHES TO ARCHITECT FOR APPROVAL. 2.SUBMITTALS MUST BE APPROVED BEFORE PLACING ORDERS WHERE MATERIALS ARE NOT RETURNABLE. 3.G.C. TO NOTIFY ARCHITECT OF ITEMS W/ LONG LEAD TIMES. 4.NO FINISH SUBSTITUTIONS MAY BE MADE W/O PRIOR WRITTEN AUTHORIZATION BY ARCHITECT. 5.ALL FINISHES SHALL BE APPLIED IN STRICT ACCORDANCE W/ MANUFACTURER'S SPECIFICATIONS. 6.APPLICATION OF INTERIOR FINISHES SHALL BE IN ACCORDANCE W/ WITH THE LATEST ADDITION OF THE CALIFORNIA BUILDING CODE AND CALIFORNIA GREEN BUILDING CODE (SEE TITLE SHEET AND CAL GREEN SHEETS). 7.THE MAXIMUM FLAME SPREAD CLASSIFICATION OF FINISH MATERIALS USED FOR INTERIOR FINISHES SHALL NOT EXCEED THAT SET FORTH IN THE LATEST ADDITION OF THE CALIFORNIA BUILDING CODE (SEE TITLE SHEET AND FINISH SCHEDULE). 8.THE SMOKE DENSITY OF MATERIALS OF FINISH MATERIALS USED FOR INTERIOR FINISHES SHALL NOT EXCEED THAT SET FORTH IN THE LATEST ADDITION OF THE CALIFORNIA BUILDING CODE (SEE TITLE SHEET AND FINISH SCHEDULE). 9.VERIFICATION OF COMPLIANCE WITH CALIFORNIA GREEN CODE REQUIREMENTS SHALL BE PROVIDED AS REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL BE PREPARED AND SUBMITTED BY THE CONTRACTOR. 10.ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. BEGINNING WORK IMPLIES ACCEPTANCE OF CONDITION. 11.ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY. WHEN THE WORK IS COMPLETE, IT SHALL BE FREE FROM BUCKLES, BUBBLES, OPEN JOINTS, OR IMPERFECTIONS. SEAMS SHALL BE KEPT IN ACCURATE ALIGNMENT ALONG BOTH COORDINATES. 12.GENERAL CONTRACTOR TO PROVIDE TEMPORARY PROTECTION FOR ALL INSTALLED FINISHES AS WORK PROGRESSES. 13.GYPSUM BOARD WALLS SHALL BE LEVEL 4 FINISH U.N.O 14.GYPSUM BOARD CEILINGS SHALL BE LEVEL 5 FINISH U.N.O. 15.PROVIDE MOISTURE RESISTANT GYPSUM BOARD IN AREAS SUBJECT TO MOISTURE (IE: TOILETS, KITCHEN'S). 16.TYPE AND INSTALLATION REQUIREMENTS OF SUBSTRATE FOR SPECIFIED FINISH(ES) SHALL BE FURNISHED AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND INDUSTRY STANDARDS. 17.ALL PAINT SHALL BE APPLIED IN ACCORDANCE W/ THE MANUFACTURER'S SPECIFICATION FOR THAT PARTICULAR SURFACE. 18.ALL WALLS SHALL RECEIVE ONE (1) PRIMER COAT & TWO (2) TOP COATS OF PAINT MINIMUM, U.N.O. PAINT FINISH SHALL HAVE CONSISTENT COVERAGE, FREE OF ROLLER OR BRUSH MARKS. 19.PAINT FINISH ON SURFACES INCLUDING: DOOR FRAMES, HANDRAILS, ELEVATOR DOORS, ETC. SHALL BE PAINTED SEMI-GLOSS, U.N.O. 20.ALL METAL ACCESS DOORS SHALL BE PAINTED TO MATCH ADJACENT WALL OR CEILING FINISH. ANY GRAPHICS ON DOORS SHALL BE REMOVED AND REAPPLIED AFTER PAINTING. 21.WALL COVERING SUB-CONTRACTOR TO SUBMIT SEAMING MOCK-UP SAMPLES ON GYP. BOARD OF ALL SPECIFIED WALL COVERINGS FOR APPLICATION PRIOR TO PLACEMENT OF ORDER. 22.FLOORING SHALL MEET ALL CURRENT NON-SLIP STANDARDS & REQUIREMENTS (WET & DRY CONDITION) SPECIFIED BY APPLICABLE CODES &/OR AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. CONTRACTOR SHALL PROVIDE NON-SLIP COATINGS AS NECESSARY TO MEET THESE REQUIREMENTS. 23.FLOORING SUB-CONTRACTORS TO SUBMIT SEAMING & INSTALLATION DIAGRAM W/ SUBMITTAL PACKAGE. 24.CONTRACTOR TO FIELD VERIFY EXISTING CONDITION OF FLOORS RECEIVING NEW FINISH. CONTRACTOR SHALL INCLUDE ALL REQUIRED FLOOR PREPARATION IN BID. PROVIDE PRICE TO FLOAT FLOOR WHERE NECESSARY TO ACHIEVE TOLERANCE OF 1/4" MAX. IN 10'-0'' SPAN. 25.ALL CERAMIC & VINYL COMPOSITION TILES TO BE INSTALLED W/ FULL TILE FROM TRANSITION AT DOOR & FULL TILE FROM WALL PERPENDICULAR TO DOOR, U.N.O. 26.G.C. TO COORDINATE THE INSTALLATION OF WALL BASE W/ ANY MILLWORK. 27.CERAMIC, PORCELAIN, AND OR QUARRY TILE GENERAL NOTES: A. ALL FLOORS IN WET AREAS (IE: KITCHEN AND TOILET ROOMS) SCHEDULED TO RECEIVED TILE, SHALL BE WATERPROOFED TO 6" A.F.F WITH REDGARD WATERPROOFING AND CRACK PREVENTION MEMBRANE OR APPROVED EQUAL PRIOR TO APPLICATION OF TILE. B. PROVIDE SOFT JOINT ON THE INTERIOR AT A MAXIMUM OF 25' IN EACH DIRECTION EXCEPT WHERE EXPOSED TO DIRECT SUNLIGHT (HEAT) OR MOISTURE A MAXIMUM OF 12' IN EACH DIRECTION. PERIMETER JOINTS AND MOVEMENT JOINTS ARE REQUIRED WHERE TILE WORK ABUTS RESTRAINING SURFACES SUCH AS PERIMETER WALLS, DISSIMILAR FLOOR FINISHES, CURBS, COLUMNS, PIPES, CEILINGS, AND WHERE CHANGES OCCUR IN BACKING MATERIALS, BUT NOT AT DRAIN STRAINERS. CHANGES OF PLANE, INTERIOR MOVEMENT JOINTS REQUIRED AT ALL INSIDE AND OUTSIDE CORNERS. C. ALL EXPANSION, COLD, ISOLATION CONTRACTION AND SEISMIC JOINTS IN THE STRUCTURE SHOULD CONTINUE THROUGH THE TILE WORK, INCLUDING SUCH JOINTS AT VERTICAL SURFACES. D. TILE GROUT SHALL BE SEALED W/ AQUAMIX "SEALER'S CHOICE" OR APPROVED EQUAL. 28.AFTER CLEANING, THE CONTRACTOR SHALL PROVIDE TWO (2) APPLICATIONS OF AN APPROVED NON-SLIP WAX TO RESILIENT TILE FLOOR, WHICH SHALL BE THOROUGHLY MACHINE-BUFFED & LEFT IN CONDITION ENTIRELY ACCEPTABLE TO ARCHITECT. 31. CONTRACTOR SHALL PATCH & REPAIR ANY EXISTING OR NEW FINISHES TO MATCH EXISTING OR NEW FINISHES THAT ARE COMPROMISED BY THE NEW WORK QT QT 27 A401 CT & PAINTED GYP. BD. CT & FRP PANELS OVER GYP. BD. - CT & FRP PANELS OVER GYP. BD. CT & FRP OVER GYP. BD. CT & FRP OVER GYP. BD.PT - GYP. BD.GYPSUM BOARD SS SOLID SURFACE FINISH NOTES FRP FIBER REINFORCED POLYMER SEE INTERIOR ELEVATIONS ON SHEET A401 FOR ADDITIONAL FINISH INFORMATION FLOORING INCLUDES 4" TALL (MINIMUM) 3/8" COVED QUARRY TILE BASE FINISH SCHEDULE NOTES KITCHEN HOOD UTILITY CABINET (ATTACH TO WALL WITH 5/16" x 1-1/2" SELF TAPPING SCREWS EQUALLY SPACED (TOP & BOTTOM) TO METAL STUDS (MIN. OF 3 STUDS)23.38 20 A515 20 A515 20 A515 PROVIDE DOOR CLOSER AS REQUIRED (DOOR SHALL BE SELF CLOSING)8.05 FINAL INSPECTION AND APPROVAL ARE REQUIRED PRIOR TO THE START OF OPERATION. THE DEPARTMENT REQUIRES AT LEAST THREE WORKING DAYS NOTICE PRIOR TO THE DATE OF THE FINAL INSPECTION. BEFORE STARTING CONSTRUCTION, A BUILDING PERMIT MUST BE OBTAINED FROM YOUR BUILDING AND SAFETY DEPARTMENT ANY CHANGES TO APPROVED PLAN MUST BE BROUGHT TO YOUR PLAN CHECKERS ATTENTION WARNING!! IT IS MISDEMEANOR VIOLATION TO BEGIN OPERATION WITHOUT A FINAL INSPECTION AND A VALID HEALTH PERMIT/LICENSE. YOUR HEALTH PERMIT/LICENSE WILL BE ISSUED BY LA COUNTY HEALTH OFFICER AT THE JOB SITE. REMODELED AREAS OF EXISTING FOOD ESTABLISHMENT/FACILITY MUST ALSO HAVE A FINAL INSPECTION. COUNTY OF LOS ANGELES - DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALTH - PLAN CHECK PROGRAM THE PROPOSED CONSTRUCTION/EQUIPMENT INSTALLATION IS APPROVED: Warehouse– SR0352922 TYPE OF ESTABLISHMENT/SERVICE REQUEST# THE APPROVAL DOES NOT AUTHORIZE THE VIOLATION OF ANY LAW, ORDINANCE OR REGULATION. APPROVED: 10/31/2023_ BY: Vicki Ngo__ DATE PLAN CHECK INSPECTOR (SEE PLAN APPROVAL SHEET, ATTACHED) LOS ANGELES COUNTY DEPARTMENT OF PUBLIC HEALTH PLAN CHECK PROGRAM 5050 COMMERCE DR BALDWIN PARK, CA 91706 (626) 430-5560 WWW.PUBLICHEALTH.LACOUNTY.GOV/EH SPECIALIZED SURVEILLANCE AND ENFORCEMENT BRANCH ENVIRONMENTAL HEALTH DEPARTMENT OF PUBLIC HEALTHwCOUNTY OF LOS ANGELES PLAN CHECK PROGRAM - BALDWIN PARK 5050 COMMERCE DR, BALDWIN PARK, CA 91706 PHONE: (626) 430-5560 OFFICIAL PLAN REVIEW REPORT 10/02/2025DATE EHS VICKI NGO PLAN CHECK NUMBER SR0418634 PROGRAM ELEMENT 1702 - RESTAURANT (501-1,999 SF) OWNER / REQUESTER DANIEL FUKUMOTO, DESIGNER DBA TATAYPA PERUVIAN KITCHEN / JORGE WONG ADDRESS 400 S BALDWIN AVE STE FC2, ARCADIA, CA 91007 CHARGEABLE PLAN REVIEW STATUS: APPROVED CORRECTIONS COMPLETED DATE CORRECTEDCORRECTION CATEGORY DATE IDENTIFIED 10/01/2025WAREWASHING FACILITIES 09/04/2025 10/01/2025HANDWASHING FACILITIES 09/04/2025 10/01/2025JANITORIAL FACILITIES 09/04/2025 10/01/2025TOILET FACILITIES 09/04/2025 10/02/2025WATER SUPPLY 09/04/2025 10/02/2025WASTE WATER/PLUMBING 09/04/2025 10/01/2025EQUIPMENT/STORAGE 09/04/2025 10/01/2025VENTILATION09/04/2025 10/01/2025VERMIN EXCLUSION/ENCLOSURE 09/04/2025 ADDITIONAL REQUIREMENTS FINAL FACILITY APPROVAL IS CONTINGENT UPON THE ON SITE INSPECTION AND APPROVAL OF THE FOOD EQUIPMENT AND THE PREMISES. Help us serve you better by completing a short survey. Visit our website at www.publichealth.lacounty.gov/eh. Page 1 of 3EHS Signature OFFICIAL PLAN REVIEW REPORT 10/02/2025DATE EHS VICKI NGO PLAN CHECK NUMBER SR0418634 PROGRAM ELEMENT 1702 - RESTAURANT (501-1,999 SF) OWNER / REQUESTER DANIEL FUKUMOTO, DESIGNER DBA TATAYPA PERUVIAN KITCHEN / JORGE WONG ADDRESS 400 S BALDWIN AVE STE FC2, ARCADIA, CA 91007 COMMENTS PLANS ARE APPROVED. FINAL FACILITY APPROVAL IS CONTINGENT UPON THE ON SITE INSPECTION AND APPROVAL OF THE FOOD EQUIPMENT AND THE PREMISES. CONTACT VICKI NGO AT 626-430-5557 OR VINGO@PH.LACOUNTY.GOV TO SCHEDULE AN APPOINTMENT FOR FINAL FIELD INSPECTION. CALL AT LEAST 3 TO 5 WORKING DAYS PRIOR TO ARRANGE FOR A FINAL INSPECTION. A FINAL INSPECTION SHALL BE CONDUCTED AND A PUBLIC HEALTH PERMIT OBTAINED PRIOR TO OPENING AND OPERATING THIS FOOD ESTABLISHMENT. THE FOLLOWING MUST BE COMPLIED WITH PRIOR TO CALLING FOR A FINAL INSPECTION: 1. ALL BUILDING AND SAFETY (MECHANICAL, PLUMBING, ELECTRICAL AND FIRE) AND OTHER ENFORCEMENT AGENCIES FINAL INSPECTIONS MUST BE SIGNED OFF PRIOR TO HEALTH DEPARTMENT FINAL APPROVAL IF NEEDED. 2. THE HEALTH DEPARTMENT APPROVED PLANS MUST BE AVAILABLE AT THE JOB SITE AT THE TIME OF INSPECTION. 3. ALL UTILITIES MUST BE ON AND OPERATIONAL. HOT WATER MUST BE AT 120F AND ABOVE. ALL REFRIGERATION UNITS MUST BE 41F AND BELOW. EXHAUST FAN MUST BE OPERATIONAL. 4. ALL FOOD AND UTENSIL RELATED EQUIPMENT SHALL HAVE AN ANSI CERTIFICATION. THE FOLLOWING DOCUMENTS MUST BE PROVIDED AT THE TIME OF FINAL INSPECTION: 1. BUILDING AND SAFETY FIELD CARD WITH FINAL SIGNATURES. 2. SELLER'S PERMIT 3. BUSINESS LICENSE 4. OWNER INFORMATION (DRIVER LICENSE FOR INDIVIDUAL OWNER, ARTICLES OF INCORPORATION AND EIN FOR CORPORATION). 5. PUBLIC HEALTH PERMIT APPLICATION IF CONSTRUCTION IS NOT COMPLETED WITHIN TWELVE (12) MONTHS FROM THE DATE OF APPROVAL, NEW PLAN SUBMISSION AND APPROVAL SHALL BE REQUIRED. ONE SET OF HEALTH DEPARTMENT APPROVED PLANS SHALL BE ON THE JOB SITE AT ALL TIMES DURING CONSTRUCTION. ANY CHANGES TO THE APPROVED PLANS MUST BE BROUGHT TO THE PLAN CHECKERS ATTENTION Help us serve you better by completing a short survey. Visit our website at www.publichealth.lacounty.gov/eh. Page 2 of 3EHS Signature OFFICIAL PLAN REVIEW REPORT 10/02/2025DATE EHS VICKI NGO PLAN CHECK NUMBER SR0418634 PROGRAM ELEMENT 1702 - RESTAURANT (501-1,999 SF) OWNER / REQUESTER DANIEL FUKUMOTO, DESIGNER DBA TATAYPA PERUVIAN KITCHEN / JORGE WONG ADDRESS 400 S BALDWIN AVE STE FC2, ARCADIA, CA 91007 DISCLOSURES Prior to construction and approval from the Los Angeles County Department of Public Health Environmental Health Division (DPH-EH) Plan Check Program, final inspections must be obtained from Building and Safety (mechanical, plumbing, electrical) and all other enforcement agencies. Failure to obtain a Public Health Permit/ License prior to operation of the facility/establishment is a misdemeanor violation. Construction of the food facility/ establishment must be completed and approved within twelve (12) months from the date of approval to avoid submitting new plans. A copy of the approved plans must be available at the time of the field construction review. All utilities must be on and operational at the time of the field construction review. Please contact your plan check inspector at least 3 days prior to the field construction review. Two field inspections will be covered under the Plan Check fees assessed upon plan submission. A charge will be assessed for each subsequent field construction review. Help us serve you better by completing a short survey. Visit our website at www.publichealth.lacounty.gov/eh. Page 3 of 3EHS Signature