HomeMy WebLinkAbout52 E Huntington Dr - 2025 - Boiling CrabSHEET INDEX PROJECT SUMMARY CODE ANALYSIS: PROJECT ADDRESS: SEPARATE SUBMITTALS: OWNER : ENGINEER CONSTRUCTION TYPE: PROJECT DESCRIPTION: SCOPE OF WORK: (N) OCCUPANCY GROUP: NUMBER OF STORIES: SITE PLAN 52 E HUNTINGTON DRIVE., ARCADIA, CA 91006 GENERAL NOTES ’ ’ ’ ’ VICINITY MAP GA. GAUGE VERT. VERTICAL INFO. HORIZ. GALVGYP. BD. I.C. I.D.INFORMATIONINSIDE DIAMETER HORIZONTAL GYPSUM BOARD INTERCOM GALVANIZED W.I. W/O W/ VEST. WROUGHT IRON WITHOUT WITH VESTIBULE STRUC. S.S., ST.S. PLYW'D OPEN'G ABOVE FINISHED FLOORA.F.F. MIN. F.H.C. ELEV. EXIST'G DETS DET. E.P. FTG EQ. FLRFIN. F.G. (E) EL. DIA ELECTRICAL PANEL T.A. FIRE HOSE CABINET FINISH, FINISHED FINISH GRADE FOOTING EQUAL FLOOR U.N.O. V.C.T. T.B. TYP. T.W. T.C. ELEVATION, ELEVATOR EXISTING ELEVATION EXISTING DIAMETERDETAILS DETAIL S. T.O. SHT SIM. S.F. ADMIN. CMU CONC. CLSR'M CEM. PLAS. CL'G CEM.C.B. B.L. B.N.BLD'G AC.T. C.T. CLR C.F. CEMENT O.D.CERAMIC TILE CEMENT PLASTER CONCRETE CLASSROOM CLEAR CUBIC FEETCEILING PR. REQ. PL. OPP. ADMINISTRATION CHALK BOARD BUILDING LINE ACOUSTICAL TILE BULL NOSEBUILDING MET. O.C. N.I.C.NO. (N) M.B. A.C.ASPHALTIC CONCRETE MAX. MINIMUM TACK BOARD TYPICAL TOP OF WALL STAINLESS STEEL STANDARD TOP OF STRUCTURAL SIMILAR SQUARE FEET SHEET OUTSIDE DIAMETER REQUIRED PLYWOOD PAIR PLATE OPENINGOPPOSITE NOT IN CONTRACT MARKER BOARD METAL ON CENTER NUMBER NEW MAXIMUM CONCRETE MASONRY UNIT ABBREVIATIONS COVER SHEET GENERAL NOTES GENERAL NOTES ACCESSIBILITY NOTES ACCESSIBILITY NOTES ACCESSIBILITY DETAILS FLOOR FINISH PLAN FLOOR FINISH PLAN G-001 A-000 A-001 A-002 A-003 A-004 A-102 A-103 DETAIL NUMBER DETAIL NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NUMBER A SHEET NUMBER DETAIL NUMBER A-4 2 SECTION DETAIL A-4 2 103 ROOM NAME W1 D3 W6 N 1 1 KEYNOTE WALL TAG ROOM NAME+0'-0" A.F.F. FLOOR PLAN A-101 SYMBOLS A-4 2 BUILDING HEIGHT: FINISH TAG1 B NORTH DEMOLITION PLANA-100 DESIGNER: BUILDING SUMMARY PROJECT CONSULTANTS SITE DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP 52 E HUNTINGTON DRIVE., ARCADIA, CA 91006 NORTH The Boiling Crab HUNTINGTON DRIVE EGRESS PLAN REFLECTED CEILING PLAN A-104A A-104 OCCUPANT LOAD: DEMOLITION PLANA-100A A-101A EGRESS PLAN A-102A FLOOR PLAN A-103A REFLECTED CEILING PLAN ROUGH-IN FLOOR PLAN ROUGH-IN FLOOR PLANA-105A A-105 INTERIOR ELEVATIONSA-200 EXTERIOR ELEVATIONSA-300 ENLARGED RESTROOM PLANS & ELEVATIONSA-400 ENLARGED RESTROOM PLANS & ELEVATIONSA-401 DETAILSA-500 SCHEDULEA-600 EQUIPMENT PLANQ-101 EQUIPMENT SCHEDULEQ-102 KITCHEN INTERIOR ELEVATIONSQ-200 INTERIOR ELEVATIONSA-201 INTERIOR ELEVATIONSA-202 INTERIOR ELEVATIONSA-203 DETAILSA-501 DETAILSA-502 DETAILSA-503 S 1 S T A V E KITCHEN INTERIOR ELEVATIONSQ-201 M.E.P. ENGINEER EQUIPMENT PLANQ-101A MECHANICAL SCHEDULES & NOTES MECHANICAL FLOOR PLAN E5 ELECTRICAL ROOF PLAN E3 PANEL SCHEDULES, SYMBOLS, & NOTESE1 LIGHTING PLAN M3 M2 POWER PLANE2 E4 EQUIPMENT PLAN E7 DINING ROOM EMERGENCY PHOTOMETRIC PLAN M1 HVAC PLAN EQUIPMENT SCHEDULE M5 M4 MECHANICAL SECTIONSM6 MECHANICAL DETAILSM10 MECHANICAL TITLE 224M11 MECHANICAL TITLE 24M12 HOOD DRAWINGSM7 HOOD DRAWINGSM8 HOOD DRAWINGSM9 PLUMBING SCHEDULES & NOTESP1 HOT & COLD WATER PLANP3 WASTE & VENT FLOOR PLANP4 PLUMBING GAS PLANP5 EQUIPMENT SCHEDULEP2 MECHANICAL ROOF PLAN G-001 COVER SHEET ENLARGED SITE PLANG-002 (E) USE & OCCUPANCY GROUP: AREA OF WORK: (E) ALLEY DETAILSA-504 STRUCTURAL SHEETSS1 STRUCTURAL SHEETSS2 INTERIOR ELEVATION REVISION CLOUD & DELTA NORTH ARROW DATUM ELEVATION DOOR NUMBER ROOM NUMBER & NAME EQUIPMENT NUMBER TOP OF ASPHALT PAVING TOP OF CONC., T.O. CURB UNLESS NOTED OTHERWISE VINYL COMBINATION TILE STRUCTURAL SHEETSS3 E6 COMPLIANCE REPORT T-24 STRUCTURAL SHEETSS4 ASSESSOR PARCEL NO.: LEGAL DESCRIPTION: ALLOWABLE AREA: BUILDING SUMMARY SITE DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP G-002 COVER SHEET SITE PLAN 52 E HUNTINGTON DRIVE., ARCADIA, CA 91006 NORTH The Boiling Crab HUNTINGTON DRIVE S 1 S T A V E (E) ALLEY CONSTRUCTION TYPE: (N) OCCUPANCY GROUP: NUMBER OF STORIES: BUILDING HEIGHT: (E) USE & OCCUPANCY GROUP: AREA OF WORK: ASSESSOR PARCEL NO.: LEGAL DESCRIPTION: ALLOWABLE AREA: GENERAL CONSTRUCTION NOTES GENERAL NOTES DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-000 GENERAL NOTES GENERAL NOTES (CONT.) DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-001 GENERAL NOTES ACCESSIBILITY REQUIREMENTS ⅛ DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-002 ACCESSIBILITY NOTES ACCESSIBILITY REQUIREMENTS 1 ⅛ DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900,Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-003 ACCESSIBILITY NOTES 14TYP. DIMENSIONS FOR TOILET FIXTURES SCALE: N.T.S. 15KNEE CLEARANCE @ LAVATORY SCALE: N.T.S.11RESTROOM DOOR SYMBOL SCALE: N.T.S. 12TOILET DOOR SYMBOL SCALE: N.T.S. 7INTERNATIONAL ACCESSIBILITY SYMBOL SCALE: N.T.S. EXIT ROUTE EXIT 8REQUIRED KNEE CLEARANCE SCALE: N.T.S.4(N) ACCESSIBLE PARKING SIGN SCALE: N.T.S. 5ACCESSIBLE PARKING TOW-AWAY SIGN SCALE: N.T.S. 6NOT USED SCALE: N.T.S. 16CLEAR DOOR WIDTH AND DEPTH SCALE: N.T.S. 20FORWARD REACH SCALE: N.T.S. 18SIDE REACH SCALE: N.T.S. 10TACTILE EXIT SIGN SCALE: N.T.S. 2NEW ACCESSIBLE PARKING DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP 3NOT USED A-004 ACCESSIBILITY DETAILS DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-100 DEMOLITION PLAN GENERAL NOTES:KEYNOTES N WALL LEGEND NO. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 1 1 1 1 4 1 1 1 1 2 2 2 1 1 2 2 3 3 3 4 4 5 6 6 6 6 6 6 6 77 7 8 6 9 EXISTINGRETAIL AREA EXISTING RETAILSTORAGE AREA 13 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-100A DEMOLITION PLAN GENERAL NOTES:KEYNOTES N WALL LEGEND NO. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 1 4 4 1 1 2 1 1 2 5 6 6 8 2 11 2 6 4 12EXISTING OFFICEAREA EXISTINGOFFICE AREA DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-101 EGRESS PLAN N EXIT COMMON PATH OF TRAVEL DIRECTIONALLIGHT EMERGENCY LIGHT EXIT / EMERGENCYLIGHT PLUMBING FIXTURE CALCULATION TABLE 422.1 WATER CLOSET LAVATORIESURINAL AREA OCCUPANTSQ. FT.LEGENDTYPE OF OCCUPANCY A B C D E G LOAD FACTOR GROUP CLASS - B A-2 FIRE NOTES: CLASS - B CLASS - C INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY OCCUPANCY TABULATION TABLE A: OCCUPANT LOAD FACTOR (CPC 2022) OCCUPANT LOAD: F LEGENDTABLE 803.13 OCCUPANT LOAD OCCUPANT LOAD FACTOR (PER CBC 2022) OCCUPANT LOAD: TD FS FS FS FS FS FD FD FS FS FD FD FD FD FD EX I T EXIT WAITING AREA 101 TRASH AREA 102 DINING AREA 1 103 DINING AREA 2 104 HAND WASH AREA 105 HALLWAY 106 SERVICE AREA 107 KITCHEN AREA 108 PREP AREA 109 WAREWASHING AREA 110 BEER STORAGE ROOM 111 WALK-IN COOLER 113 WALK-IN FREEZER 114 WOMEN'S RESTROOM 115 MEN'S RESTROOM 116 HOSTESS STATION 100 SERVICEAREA 107 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-101A EGRESS PLAN N EXIT COMMON PATH OF TRAVEL DIRECTIONALLIGHT EMERGENCY LIGHT EXIT / EMERGENCYLIGHT LEGEND EXIT OFFICE AREA 117 OFFICE AREA 117 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP REFER TO SHEET A-600 FOR FISH SCHEDULES & NOTES. NOTE ACCESSIBILITY NOTES A-102 FLOOR PLAN FLOOR PLAN KEYNOTES 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 19 20 21 22 23 24 25 26 N TD FS FS FS FS FS FD FD FS FS FD FD FD FD FD 1 A-200 W2 D1 HOSTESS STATION 100 W2 W1 W2 W0 W0 W1 W1 W0 W0 W1 W0 W0 W0 W3 W3 W3 W3 W5 W1 W1 W3 W3 W3 W4 W4 W4 W4 W4 W4 W4 W4 W4 W5 W7 W7 W7 W6W6 W6 W6 W5 1 4 2 3 5 5 6 7 8 8 8 8 8 8 10 10 10 11 11 12 13 14 14 15 16 17 1 A-502 18 18 18 26 20 21 21 21 21 21 21 21 21 21 21 21 9 23 23 24 25 25 W4 WAITING AREA 101 TRASH AREA 102 DINING AREA 1 103 DINING AREA 2 104 HAND WASH AREA 105 HALLWAY 106 SERVICE AREA 107 KITCHEN AREA 108 PREP AREA 109 WAREWASHING AREA 110 BEER STORAGE ROOM 111 19 WALK-IN COOLER 113 WALK-IN FREEZER 114 WOMEN'S RESTROOM 115 MEN'S RESTROOM 116 2 A-200 1 A-201 2 A-201 3 A-202 1 A-202 2 A-202 3 A-201 1 Q-200 2 Q-200 3 Q-200 4 Q-200 6 Q-200 5 Q-200 1 Q-201 2 Q-201 3 Q-203 3 Q-201 4 Q-201 D2 D3 D3 D4 D5 D5 D6 1 A-400 W0 W0 2 3 W4 10 10 10 W4 9 W4 SERVICE AREA 117 10 1 A-401 W6 2 2 W0 W0 W0 6 A-501 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP REFER TO SHEET A-600 FOR FINISH SCHEDULES & NOTES. NOTE FLOOR PLAN KEYNOTES 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 19 20 21 22 23 24 25 26 A-102A FLOOR PLAN N W1 W1 W1 W1 W1 W1 W1 W1 8 8 8 8 16 EXISTING OFFICE AREA 117 1 A-203 3 A-203 2 A-203 D7 D7 EXISTING OFFICE AREA 117 N DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP SEE SCHEDULE AND NOTES AT SHEET A-5.00 NOTE: KEYNOTES 1 2 3 4 5 BUILDING NOTES LEGEND EXIT COMMON PATH OF TRAVEL DIRECTIONALLIGHT EMERGENCY LIGHT EXIT / EMERGENCYLIGHT 6 A-103 REFLECTED CEILING PLAN ELECTRICAL FIXTURE LEGEND SYMBOL DESCRIPTION LAMP X WATTS REMARK 1 2 1 1 4 4 6 6 18A-500 17A-500 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-103A REFLECTED CEILING PLAN N KEYNOTES 1 2 3 4 5 BUILDING NOTES LEGEND EXIT COMMON PATH OF TRAVEL DIRECTIONALLIGHT EMERGENCY LIGHT EXIT / EMERGENCYLIGHT 6 SEE SCHEDULE AND NOTES AT SHEET A-5.00 NOTE: ELECTRICAL FIXTURE LEGEND SYMBOL DESCRIPTION LAMP X WATTS REMARK N DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP FLOOR FINISH SCHEDULE WALL BASE SCHEDULE B-3 DESCRIPTION: MANUFACTURER: PRODUCT: B-1 DESCRIPTION: MANUFACTURER:PRODUCT: B-2 DESCRIPTION: MANUFACTURER:PRODUCT: B-4 DESCRIPTION: MANUFACTURER: PRODUCT:FINISH: EW-1 DESCRIPTION: MANUFACTURER: PRODUCT: F-1 DESCRIPTION:MANUFACTURER: PRODUCT: F-2 DESCRIPTION:MANUFACTURER: PRODUCT: REMARKS: F-3 DESCRIPTION: MANUFACTURER: PRODUCT: A-104 FLOOR FINISH PLAN NOTES: TD FS FS FS FS FS FD FD FS FS FD FD FD FD FD F-2 F-3 F-1 B-1 B-1 B-1 B-4 B-4 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-4 B-4 B-3 B-3 B-3 B-3 B-3 B-3 B-3 B-3 B-1 B-1 B-1 B-1 F-2 F-2 B-1B-1 B-1 B-1 B-1 B-1 B-1B-1 B-1 B-1B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2 B-2B-2 B-2 B-2 B-2 F-1 F-1 F-1 F-2 F-2 F-2 F-3 2A-103 2 A-103 2 A-103 B-4 B-4 B-4F-1 B-2 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP N A-104A FLOOR FINISH PLAN FLOOR FINISH SCHEDULE WALL BASE SCHEDULE B-3 DESCRIPTION: MANUFACTURER: PRODUCT: B-1 DESCRIPTION: MANUFACTURER:PRODUCT: B-2 DESCRIPTION: MANUFACTURER:PRODUCT: B-4 DESCRIPTION: MANUFACTURER: PRODUCT:FINISH: EW-1 DESCRIPTION: MANUFACTURER: PRODUCT: F-1 DESCRIPTION:MANUFACTURER: PRODUCT: F-2 DESCRIPTION:MANUFACTURER: PRODUCT: REMARKS: F-3 DESCRIPTION: MANUFACTURER: PRODUCT: F-2 F-2 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-105 ROUGH-IN FLOOR PLAN N TD FS FS FS FS FS FD FD FS FS FD FD FD FD FD HOSTESSSTATION 100 WAITING AREA 101 TRASH AREA 102 DINING AREA 1 103 DINING AREA 2 104 HAND WASH AREA 105 HALLWAY 106 SERVICEAREA 107 KITCHENAREA 108 PREP AREA 109 WAREWASHING AREA 110 BEER STORAGEROOM 111 WALK-INCOOLER 113 WALK-INFREEZER 114 WOMEN'SRESTROOM 115 MEN'SRESTROOM 116 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP N A-105A ROUGH-IN PLAN EXISTING OFFICE AREA 117 EXISTING OFFICE AREA 117 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-200 INTERIOR ELEVATIONS B-1 T-1 WP-2 B-1WP-1 WP-1 MF-1WP-2MF-1 B-1T-1 FIN. FLOOR 0'-0" A.F.F. OPEN CEILING @ DINING AREA VERIFY HEIGHT WP-2 MF-1 P-2 P-2 B-1 FIN. FLOOR 0'-0" A.F.F. OPEN CEILING @ DINING AREA VERIFY HEIGHT B-1 T-1 P-2 B-1 P-2 B-1 B-1 P-2 MF-2 P-2 B-1 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-201 INTERIOR ELEVATIONS MF-2 B-1 WP-2 MF-1 WP-1 B-1 WP-1 MF-1MF-1 FIN. FLOOR0'-0" A.F.F. MF-1 OPEN CEILING @DINING AREAVERIFY HEIGHT P-2 FIN. FLOOR 0'-0" A.F.F. OPEN CEILING @ DINING AREA VERIFY HEIGHT MF-1 WP-2 B-1 P-2 MF-1 MF-4 P-2 B-1 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @ HAND WASH AREA +9'-0" A.F.F. WP-3 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-202 INTERIOR ELEVATIONS B-1T-1 MF-1 WP-2 P-2 P-2 B-1 FIN. FLOOR 0'-0" A.F.F. OPEN CEILING @DINING AREA VERIFY HEIGHT B.O. SOFFIT +9'-0" A.F.F. T-1 MF-4 WP-5P-2 MF-1 P-2 B-1 B-1T-1 B-1T-1 P-2 FIN. FLOOR 0'-0" A.F.F. OPEN CEILING @ DINING AREA VERIFY HEIGHT B.O. SOFFIT @ SERVICE AREA +9'-0" A.F.F. B-1 MF-5 MF-5 MF-1 WP-2 FIN. FLOOR 0'-0" A.F.F. OPEN CEILING @DINING AREA VERIFY HEIGHT P-2 MF-1 WP-2 B-1 WP-2WP-2 B-1 B-1 P-2P-2 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-203 INTERIOR ELEVATIONS FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @ STORAGE AREA +8'-0" A.F.F. (V.I.F.) B-2 B-2 WP-4 WP-4 WP-4 WP-4 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @ STORAGE AREA +8'-0" A.F.F. (V.I.F.) B-2 B-2 WP-4 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @STORAGE AREA +8'-0" A.F.F. (V.I.F.) B-2 WP-4 B-2 WP-4 WP-4 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-300 EXTERIOR ELEVATIONS THE BOILING CRAB 1ENLARGED MEN'S RESTROOM PLAN SCALE: 1/2"=1'-0" GENERAL NOTES RESTROOM ACCESSORIES SCHEDULE QTY.DESCRIPTIONNO. A MAKE & MODEL B C D E F G H J K L M N O P 2MEN'S RESTROOM ELEVATIONS SCALE: 1/2"=1'-0" DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-400 ENLARGED RESTROOM PLAN 3LAVATORY SECTION DETAIL SCALE: 1/2"=1'-0" A D WP-3 T-2 ELEVATION 'A' AB B-3 A WP-3 ELEVATION 'B' B-3 T-2 EBAC T-2 ELEVATION 'D' WP-3 M N T-2 WP-3 ELEVATION 'C' B-3 B-3 A B C D 2A-400 A A B C D O O M J HJ 3- 1ENLARGED WOMEN'S RESTROOM PLAN SCALE: 1/2"=1'-0" GENERAL NOTES RESTROOM ACCESSORIES SCHEDULE QTY.DESCRIPTIONNO. A MAKE & MODEL B C D E F G H J K L M N O P 2WOMEN'S RESTROOM ELEVATIONS SCALE: 1/2"=1'-0" DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-401 ENLARGED RESTROOM PLAN A B C D 2A-401 A C B D O O A A O JHJ AB F T-2 WP-3 ELEVATION 'A' B-3 AD T-2 A A WP-3 ELEVATION 'B' B-3 E BA C T-2 ELEVATION 'C' WP-3B-3 N ELEVATION 'D' WP-3B-3 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-500 DETAILS CONDITION A CONDITION B A SLIP TRACK PERPENDICULAR TO JOIST B SLIP TRACK PARALLEL TO JOIST A PASS-THRU & BAR COOLER COUNTER - SECTION 4 SERVICE COUNTER - SECTION 2 T-1 WP-4 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP 15OVERHEAD SHELVING SCALE: N.T.S. A-501 DETAILS PASS-THRU SHELF SECTION 6 7CORNER GUARD - PLAN SCALE: 6"=1'-0" 8EPOXY BASE @ FRP & STAINLESS SCALE: 3"=1'-0" 9FIRE BLOCKING UNDER RAISED FLOOR, TYP. SCALE: 1 1/2"=1'-0" 12MOP SINK FLASHING - SECTION SCALE: 3"=1'-0" 10FULL HEIGHT BLOCKING - PLAN SCALE: 3"=1'-0"14SERVICE BAR ACCESSIBLE COUNTER - SECTION SCALE: 1 1/2"=1'-0" WP-3 T-1 7 1/4"1'-2" 1'-0 3/8" 7 1/4" 1'-0 3/8" 1 1 / 4 " 1' - 8 " 1 ' - 4 1 / 2 " 1PASS-THRU SHELF - PLAN SCALE: 1"=1'-0" 2PASS-THRU SHELF - SECTION SCALE: 1"=1'-0" 3PASS-THRU SHELF - ELEVATION SCALE: 1"=1'-0" 4PASS-THRU SHELF - ISOMETRIC SCALE: 1"=1'-0" DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP OVERSHELF 4'-1" 1'-1 1/4" WINDOW FRAME 3'-11 7/8" DIVIDER 1'-9 1/2" 2'-2 1/4" 8"3'-8" 5'-0" 8" 2'-9 1/2" 1'-1 1/4" 1'- 8 " OV E R S H E L F 1' - 4 1 / 2 " 1 1 / 2 " 1'- 5 " WI N D O W F R A M E 1' - 3 1 / 2 " 3'- 0 1 / 2 " 8 1 / 4 " 1 ' - 8 " 8 1 / 4 " 1' - 7 " 5 - A-502 DETAILS 9EXISTING ROOF ACCESS LADDER 5TRELLIS JOIST CONNECTION @ WALL SCALE: 1 1/2"=1'-0"7SECTION AT HOSTESS STATION SCALE: 1 1/2"=1'-0" 6ENLARGED TRELLIS PLAN SCALE: 1/2"=1'-0"8ENLARGED HOSTESS STATION SCALE: 1/2"=1'-0" EXISTING MEZZANINE AREA EXISTING GROUND LEVEL AREA B-1 MF-2 WP-2 B-1WP-1 WP-1 MF-1MF-1 MF-1 MF-1 WP-2 B-1WP-1 WP-1 MF-1WP-2MF-1 5 - DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-503 WALK-IN COOLER DETAILS DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP A-504 WALK-IN COOLER LARR ELECTRICAL FIXTURE LEGEND SYMBOL DESCRIPTION LAMP X WATTS REMARK FINISHMATERIALDESCRIPTION CEILING SCHEDULE MANUFACTURER CEILING NOTES C2 RO O M N U M B E R ROOM NAME ROOM FINISH SCHEDULE ROOM DESCRIPTION FLOOR BASE MATERIAL W A L L S FINISH MATERIAL C E I L I N G FINISHMATERIAL W2 W1 NO. DESCRIPTION WALL SCHEDULE WALL LEGEND W3 W4 W5 HARDWARE REMARKSCORETHKFACE/EDGEFRAME LITESIZE (WxH)MFG #NO.DESCRIPTION DOOR SCHEDULE D1 D2 D3 D4 D5 FIRE DEPT. NOTES: W6 HOSTESS STATION100 WAITING AREA101 TRASH AREA102 DINING AREA 1103 DINING AREA 2104 HAND WASH AREA105 HALLWAY106 SERVICE AREA107 KITCHEN AREA108 PREP AREA109 WAREWASHING AREA110 BEER STORAGE ROOM111 STORAGE AREA112 WALK-IN COOLER113 WALK-IN FREEZER114 WOMEN'S RESTROOM115 HEALTH DEPARTMENT NOTES DOOR TYPES BUILDING DEPT. NOTES: SCALE:1FLOOR TILE TRANSITION N.T.S. FIRE NOTES DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP C3 FLOOR FINISH NOTES DESCRIPTIONNO. MANUFACTURER MFG# COLOR REMARK MATERIAL FINISH SCHEDULE FINISH MF-1 MF-2 MF-3 INTERIOR TILE FINISH SCHEDULE FINISHDESCRIPTIONNO. SERIESMANUFACTURER COLORMFG# REMARK T-1 T-2 DESCRIPTIONNO. MANUFACTURER MFG# COLOR REMARK WALL PANEL SCHEDULE FINISH WP-1 WP-2 MF-4 WP-3 WP-4 WP-5 INTERIOR PAINT SCHEDULE P-1 NO.COLORMANUFACTURERMFG #FINISH REMARK P-2 P-3 P-4 MF-5 MEN'S RESTROOM116 D6 D7 A-600 SCHEDULES SERVICE AREA107A W7 C1 W0 D1 D2 D7 D5 D6 D3 D4 DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP Q-101 EQUIPMENT PLAN N TD FS FS FS FS FS FD FD FS FS S2 S2 S2 S3 S3 S4 S4 S5 S5 S7 S7 S8 S9 S10 S11 S12 S14 S19 S20 SB-1 SB-2 SB-5 SB-7 K1 K2 K2 K2 K2 K2 K2 K3 K3 K3 K3 K3 K3 K3 K4 K5 K5 K6 K6 K6 K8 K8 K9 K11 K12 K13 K13 K13 K13 K13 K14 K14 K14 K14 K14 K15 K15 K15 K16 K16 K16 K17 K18 K18 K19 K20 K10 KP1 KP1 KP5 KP6 KP5 KP6KP3 KP4 KP8 KP9 KS5 KP10 KW1 KW2KW3 KW4 KW3 KW4 KW5 KW6KW7KW9 KW9 KW12 KS1 KS2 KS4KS13KS15KS13 KS15 KS12 KS16 KS19 KS19 KS19 KS19 KS19 KS19 KS20 KS20 KS20 KS20 KS20 KS22 KS23 KS24 KS24 KS24 KS27 HW1 HW1 HW2HW2 HW3HW3 HW4 HW4 HW2 HW3 HW2 F1F1F1 F1 F1 F1F1 F1 F1F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1F1F1F1F1F1F1F1 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2F2F2 F2F2F2 F2F2F2 F2F2F2 F2F2F2 F2F2F2 F2F2 F2F2 F2F2 F2F2 F2F2 F2F2 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F3 F4F6 F6 F5 F5 F5 F5 F5 F5 F5 F5 F5 S2 KS25 KS25 KS25 KS25KS25 KS25 KS25 KS25 KS25KS25 KP7 F5 HW1 HW2 HW3 HW2 F1 F2 F2 F2 KS6 KS7 KS8 KS21 KS13KS-12 F5 KS9 KS12 KS6.1 S15 S16 KS7 KS8 KS21 K20 FD FD FD FD FD HOSTESSSTATION 100 WAITING AREA 101 DINING AREA 1 103 DINING AREA 2 104 HAND WASH AREA 105 HALLWAY 106 SERVICEAREA 107 KITCHEN AREA 108 PREP AREA 109 WAREWASHINGAREA 110 BEER STORAGE ROOM 111 WALK-IN COOLER 113 WALK-IN FREEZER 114 WOMEN'S RESTROOM 115 MEN'S RESTROOM 116 SERVICE AREA 107A DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP HEALTH DEPARTMENT NOTES:LEGEND: Q-102 EQUIPMENT SCHEDULE DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP Q-200 KITCHEN ELEVATIONS B-2 B-2 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @SERVICE AREA +9'-0" A.F.F. WP-3 MF-5 WP-3MF-5 WP-3 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @SERVICE AREA +8'-0" A.F.F. B-2 B-2 WP-3 B-2 B-2 WP-3 WP-3 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @ SERVICE AREA +9'-0" A.F.F.B.O. CEILING @ SERVICE AREA +8'-0" A.F.F. MF-5 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @KITCHEN AREA +8'-0" A.F.F. B-2B-2 WP-3 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @ KITCHEN AREA +8'-0" A.F.F. B-2 B-2 WP-3 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @KITCHEN AREA +8'-0" A.F.F. DRAWN BY SHEET CONTENT SHEET NO ISSUE DATE / REVISIONS: EFM CHECK BY ADR PR O J E C T N A M E / A D D R E S S : 52 E H u n t i n g t o n D r i v e . , Ar c a d i a , C A 9 1 0 0 6 DESIGNER 10 0 5 E . L a s T u n a s D r i v e , S u i t e 2 0 5 , S a n G a b r i e l , Ca l i f o r n i a 9 1 7 7 6 Em a i l : a r c h . o f f i c e d i r e c t o r @ g m a i l . c o m ENGINEER Kwei Consulting Engineers, Inc. 611 Wilshire Blvd., Suite #900, Los Angeles, CA 90017 DE S I G N , L L C Th e B o i l i n g Cr a b STAMP Q-201 KITCHEN ELEVATIONS B-2 B-2 B-2 WP-4 WP-3 WP-3 WP-3WP-3WP-4 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING @ WARE WASHING AREA +8'-0" A.F.F. WP-4 B-2 WP-4 B-2 B-2 B-2 WP-4 WP-4 WP-4 FIN. FLOOR 0'-0" A.F.F. B.O. CEILING PREP AREA +8'-0" A.F.F. FIN. FLOOR 0'-0" A.F.F. B.O. CEILING PREP AREA +8'-0" A.F.F. B-2 WP-4 B-2 B-2 B-2 B-2 B-2 WP-4 WP-4 FIN. FLOOR 0'-0" A.F.F. B.O. CEILINGPREP AREA +8'-0" A.F.F. B-2 B-2 WP-4 FIN. FLOOR 0'-0" A.F.F. B.O. CEILINGPREP AREA +8'-0" A.F.F.                                                                                                                                                                MEZZANINE FLOOR PLAN KS3 KS3 TD RICEwarmer OVEN OVEN ELEC. PANEL PA S S - T H R U SH E L F SO D A D I S P E N S E R WIT H I C E B I N TV WAITING AREA PA S S - T H R U SH E L F ICE MAKER (FLAKER) ICE BIN undercounter dishwasher IC E B I N EM P L O Y E E L O C K E R S RICEcooker WAITING BENCH WA I T I N G B E N C H FD BABY CHANGING STATION ELEC. PANEL FS STAIRS TO EXISTING MEZANNINE AREA SB-1 SB-2 SB-5 SB-7 F6 F6 S2 MO P S I N K POWER PLAN 1/4"=1'-0" MEZZANINE FLOOR PLAN 1/4"=1'-0" PNL"C"PNL"D" PNL"A" PNL"B" NEW 600 AMP 120/240 V 1PH, 3WIRE "MS"                                                                                                     MEZZANINE CEILING PLAN 1/4"=1'-0" OVEN OVEN ELEC. PANEL PA S S - T H R U SH E L F SO D A D I S P E N S E R WIT H I C E B I N TV WAITING AREA PA S S - T H R U SH E L F ICE MAKER (FLAKER) ICE BIN undercounter dishwasher IC E B I N EM P L O Y E E L O C K E R S PRINTER WAITING BENCH WA I T I N G B E N C H 7' high wall BABY CHANGING STATION ELEC. PANEL FS STAIRS TO EXISTING MEZANNINE AREA MO P S I N K 8'8'     LIGHTING PLAN 1/4"=1'-0"                                                                                                                                                                                                         WALK-IN COOLER/FREEZR CONDENSERS PLATFORM ROOF PARAPET WALL ROOF PARAPET WALL ROOF PARAPET WALL ROOF PARAPET WALL ROOF PARAPET WALL ROOF PARAPET WALL ROOF PLAN 1/4"=1'-0" ROOF PLAN 1/4"=1'-0" MUA 1 MUA 2 EF 1 EF 2 EF 3 10' 10' 10' 10' 10'                  CU 1 CU 2                                                                                                                                                                                                            MEZZANINE CEILING PLAN 1/4"=1'-0" OVEN OVEN ELEC. PANEL PA S S - T H R U SH E L F SO D A D I S P E N S E R WIT H I C E B I N TV WAITING AREA PA S S - T H R U SH E L F ICE MAKER (FLAKER) ICE BIN undercounter dishwasher IC E B I N EM P L O Y E E L O C K E R S PRINTER WAITING BENCH WA I T I N G B E N C H 7' high wall BABY CHANGING STATION ELEC. PANEL FS STAIRS TO EXISTING MEZANNINE AREA MO P S I N K LIG 4.9 5.4 5.9 6.4 6.6 6.5 6.1 5.5 4.8 4.0 3.2 2.5 5.5 5.6 5.8 6.0 6.3 6.4 6.5 6.2 5.7 4.8 3.9 3.0 2.3 7.1 6.7 6.5 6.6 7.1 7.7 8.2 8.2 7.6 6.4 5.1 3.8 2.8 9.6 8.5 7.9 8.0 8.8 10.1 11.3 11.7 10.9 9.0 6.9 5.0 3.5 12.9 10.8 9.6 9.7 11.1 13.4 15.7 16.5 15.3 12.5 9.2 6.3 4.3 16.3 13.1 11.3 11.4 13.4 16.8 20.1 21.5 19.9 15.9 11.4 7.6 5.0 18.6 14.7 12.4 12.5 15.0 19.0 23.0 22.8 18.2 12.9 8.5 5.4 18.8 14.8 12.5 12.6 15.0 19.0 23.0 22.8 18.2 12.9 8.5 5.4 16.8 13.5 11.5 11.6 13.6 16.9 20.2 21.6 20.0 16.0 11.5 7.7 5.0 13.6 11.3 10.0 10.0 11.3 13.6 15.9 16.7 15.5 12.6 9.3 6.5 4.4 10.4 9.1 8.4 8.4 9.2 10.4 11.6 12.0 11.1 9.3 7.1 5.2 3.7 8.1 7.6 7.3 7.3 7.7 8.2 8.6 8.6 8.0 6.8 5.5 4.2 3.1 6.9 6.9 7.0 7.0 7.1 7.1 7.1 6.8 6.3 5.4 4.4 3.5 2.7 7.0 7.4 7.7 7.8 7.7 7.4 6.9 6.4 5.7 4.9 4.1 3.3 2.61.9 24.7 24.7 4.9 5.4 5.9 6.4 6.6 6.5 6.1 5.5 4.8 4.0 3.2 2.5 5.5 5.6 5.8 6.0 6.3 6.4 6.5 6.2 5.7 4.8 3.9 3.0 2.3 7.1 6.7 6.5 6.6 7.1 7.7 8.2 8.2 7.6 6.4 5.1 3.8 2.8 9.6 8.5 7.9 8.0 8.8 10.1 11.3 11.7 10.9 9.0 6.9 5.0 3.5 12.9 10.8 9.6 9.7 11.1 13.4 15.7 16.5 15.3 12.5 9.2 6.3 4.3 16.3 13.1 11.3 11.4 13.4 16.8 20.1 21.5 19.9 15.9 11.4 7.6 5.0 18.6 14.7 12.4 12.5 15.0 19.0 23.0 22.8 18.2 12.9 8.5 5.4 18.8 14.8 12.5 12.6 15.0 19.0 23.0 22.8 18.2 12.9 8.5 5.4 16.8 13.5 11.5 11.6 13.6 16.9 20.2 21.6 20.0 16.0 11.5 7.7 5.0 13.6 11.3 10.0 10.0 11.3 13.6 15.9 16.7 15.5 12.6 9.3 6.5 4.4 10.4 9.1 8.4 8.4 9.2 10.4 11.6 12.0 11.1 9.3 7.1 5.2 3.7 8.1 7.6 7.3 7.3 7.7 8.2 8.6 8.6 8.0 6.8 5.5 4.2 3.1 6.9 6.9 7.0 7.0 7.1 7.1 7.1 6.8 6.3 5.4 4.4 3.5 2.7 7.0 7.4 7.7 7.8 7.7 7.4 6.9 6.4 5.7 4.9 1.9 24.7 24.7 1.6 1.8 1.8 1.7 1.5 1.3 1.1 0.9 2.5 2.8 2.8 2.6 2.3 1.9 1.6 1.3 1.0 4.0 4.4 4.4 4.1 3.5 2.9 2.3 1.8 1.4 6.3 7.0 7.1 6.4 5.4 4.2 3.2 2.4 1.9 9.6 10.9 11.0 9.8 7.9 6.0 4.4 13.9 15.9 16.0 14.2 11.1 8.1 5.7 18.0 20.9 21.0 18.4 14.3 10.1 7.0 20.2 23.5 20.8 16.0 11.3 7.9 5.9 4.8 19.4 22.6 22.8 20.1 15.7 11.3 8.3 6.6 5.9 16.0 18.6 18.8 16.7 13.5 10.3 8.2 7.3 7.4 8.1 9.20.8 23.7 ZONE#1 1.3 1.0 1.8 1.4 2.4 1.9 4.9 5.4 5.5 5.6 7.1 6.7 5.7 5.8 5.7 7.9 8.5 8.7 11.0 12.5 13.0 10.7 15.3 18.3 5.0 5.2 5.7 17.5 15.2 12.3 9.1 7.0 5.4 6.02.7 3.5 7.1 7.3 10.1 14.1 15.63.1 1.9 1.5 2.1 6.0 6.2 6.9 5.4 5.6 5.5 4.1 4.0 5.0 5.0 5.8 LUMINAIRE SCHEDULE Symbol Label Qty File Lumens LLF WattsCatalog Number Description Lamp E3 9000 1.00 63 LCBL 9000LM LED PENDANT LIGHT, 9000 Lumens, STATISTICS Description Symbol Avg Max Min Max/Min Avg/Min Calc Zone #1 13.7 fc 24.8 fc 4.5 fc 5.5:1 3.0:1 DINING ROOM EMERGENCY LIGHT PHOTOMETRIC PLAN 1/4"=1'-0"                                                                                                     1 AC ITEM MECHANICAL EQUIPMENT SCHEDULE                                                                                                       RICEwarmer OVEN OVEN ELEC. PANEL PA S S - T H R U SH E L F SO D A D I S P E N S E R WIT H I C E B I N TV WAITING AREA PA S S - T H R U SH E L F ICE MAKER (FLAKER) ICE BIN undercounter dishwasher IC E B I N EM P L O Y E E L O C K E R S RICEcooker WAITING BENCH WA I T I N G B E N C H BABY CHANGING STATION ELEC. PANEL FS STAIRS TO EXISTING MEZANNINE AREA EXIST METER TO UPGRADE NEW SERVICE TO 400 AMPS 120/208 V 3PH EXIST. METER MO P S I N K MEZZANINE FLOOR PLAN 1/4"=1'-0" SHAFT FLOOR PLAN 1/4"=1'-0" 4'-6" 11' 13' 4' 5'                                                                                                      OVEN OVEN ELEC. PANEL PA S S - T H R U SH E L F SO D A D I S P E N S E R WIT H I C E B I N TV WAITING AREA PA S S - T H R U SH E L F ICE MAKER (FLAKER) ICE BIN undercounter dishwasher IC E B I N EM P L O Y E E L O C K E R S PRINTER WAITING BENCH WA I T I N G B E N C H 7' high wall BABY CHANGING STATION ELEC. PANEL FS STAIRS TO EXISTING MEZANNINE AREA EXIST METER TO UPGRADE NEW SERVICE TO 400 AMPS 120/208 V 3PH EXIST. METER MO P S I N K CEILING PLAN MEZZANINE CEILING PLAN CEILING PLAN 1/4"=1'-0"  NOTE: Air moving systems in excess of a combined volume of 2,000 cfm are required to be equipped with anautomatic shutoff interlocked with a smoke detector located in the supply ducting of air moving system.[CMC 203 and 608]                                                                                                                                                                                                                   CONDENSATE WASTE SIZING 1. EF-1, AND MUA-1,SHALL BE ELECTRICALLY INTERLOCKED, 2. EF-2, AND MUA-2,SHALL BE ELECTRICALLY INTERLOCKED, 3. EF-3, AND MUA-2,SHALL BE ELECTRICALLY INTERLOCKED, NEW MUA UNIT NEW MUA UNIT WALK-IN COOLER/FREEZR CONDENSERS PLATFORM ROOF PARAPET WALL ROOF PARAPET WALL ROOF PARAPET WALL ROOF PARAPET WALL ROOF PARAPET WALL ROOF PARAPET WALL ROOF PLAN 1/4"=1'-0" MUA 1 MUA 2 EF 1 EF 2 EF 3 10' 10' 10' 10' 10'                                                                                                       SECTION OF EXHAUST HOOD, DUCT BLOWER, & MAKE-UP AIR SYSTEM PLATE FORM 26 GAUGE GALV. DUCT. DIFFUSER 6" MIN. 18" MIN. FIRE RATE CEILING REMOVEABLE U. L. LABEL FILTERS.45 MIN. 3/8 " THRED ROD CONNCETED TO ROOF JOIST @ 4 CORNER ANGLE SUPPORT 16 G A U G E G A L V . O R B L A C K S T E E L W E L D G R E A S E D U C T . 3" M I N . A I R S P A C E . FOLLOW ALL EQUIPMENT INSTALLATION INSTRUCTION FOR 4' - 0 " M A X . 6'- 6 " M I N . 7 ' - 0 " M A X . FLOOR OR BASE FINISH FOLLOW THE ROOM FINISH SCHEDULE & HEALTH DEPT. REQUIREMENT. 6" MIN. BEYOND THE EDGE OF THE COOKING SURFACE ON ALL OPEN SIDE. 3" MIN. AIR SPACE. HOOD LESS THAN 12" FROM CEILING MUST BE FLASHED SOLID WITH STAINLESS STEEL. 6" MIN. H. ON LEGS. COMMERCIAL COOKING EQUIPMENT FOLLOW THE INSTALLATION REQUIREMENT & INSTRUCTION TO INSTALL. ALSO GAS EQUIPMENT HAS TO HAVE A. G. A. LABEL. ELECTRIC EQUIPMENT MUST HAVE U. L. LABEL. EXHAUST OUT LETS: SHALL BE AT LEAST 40" MIN. ABOVE THE ROOF SURFACE, AT LEAST 10'-0" FROM PARTS OF THE SAME OR CONTIGUOUS BUILDINGS,ADJACENT PROPERTY LINE OR AIR INTAKE OPENING INTO ANY BUILD'G AND SHALL BE LOCATED AT LEAST 10'-0" ABOVE THE ADJOINING GRADE LEVEL. AIR VELOCITY: 1,500 FPM - 2,500 FPM NOTE: 1. KITCHEN HOOD EXHAUST DUCT BE EQUIPPED WITH TIGHT-FITTING CLEAN-OUT DOORS WHERE NECESSARY FOR MAINTENANCE. (UMC 2022) 2. ACCESS OPENING TO THE CLEAN-OUT MUST HAVE A FIRE RATED EQUAL TO SHAFT. (UMC 2022) 3. ALL COOKING EQUIPMENT MUST HAVE MIN. 6" HEIGHT NSF LEGS. OR 4" HEIGHT CONTINUOUSLY COVED BASE. OR ON APPROVED CASTERS. ROOF SCREEN MAY REQUIRED (PER BUILD'G CODE) STAINLESS STEEL HOOD WITH REMOVABLE GREASE FILTERS, U. L. LIST. HOOD SHALL BE MIN. 20 GAUGE STAINLESS STEEL. THE MAX. TOTAL DEVELOPED LENGTH OF THE DUCT OR DUCT FITTING MEASURED ALONG THE CENTER LINE SHALL NOT EXCEED 3 TIME THE VERTICAL DIMENSION OF THE FAN OUTLET. ROOF 3/8" ALL THREAD ROD CONNECTED TO ROOF JOIST AT 4 CORNER SEE SHEET M-6 THERMAL CERAMICS WRAPS DUCT INSULATION TWO LAYER SYSTEM (PER BUILDING CODE) 6'- 6 " M I N . 7 ' - 0 " M A X . COMBUSTIBLE BUILD'G INSTALLATION SPACE REQUIREMENT. 40 " M I N .  JOIST WITH SIMPSOM A-35 ATTACH STUDS TO DOUBLE ON ALL CONNERTORS 18" MIN. WHEN HOOD IS LESS THAN 18" BELOW CEILING, EXTENDED FIRE RATE CEILING 18" BEYOND THE HOOD AROUND OPEN SIDE. 18" MIN. WHEN HOOD IS LESS THAN 18" BELOW CEILING, EXTENDED FIRE RATE CEILING 18" BEYOND THE HOOD AROUND OPEN SIDE. 5/8" GYP. BOARD TYPE "X" CEILING. HOOD LESS THAN 12" FROM CEILING MUST BE FLASHED SOLID WITH STAINLESS STEEL. 16 GA. GALV. ANGLE 3" X 3" X 12" TACKWELD 6" TO MACHINE 2 #12 SHEETMETAL SCREW 2" 5/8" GYP. BOARD TYPE "X" CEILING. TO SECURE EACH END PROVIDED # 12 SHEET METAL SCREW 2" SECURE STEEL ANGLE TO THE SHAFT        SOLID WELD ON 4 SIDE 10'-0" MIN. 2 #1/2" X 3" LAG SCREWTO SECURE TO ROOF JOIST. VENTED CURB SEE SHEET A-4.1 VENTED CURB SEE SHEET A-4.1 24 " M I N . OF M E T A L C O M P L I A N C E W I T H T A B L E 6 - 1 & 6 - 2 . TH E D U C T O R D U C T F I T T I N G S H A L L B E C O N S T R U C T E D 16 G A U G E C A R B O N S T E E L W E L D G R E A S E D U C T .  EF 1 EF 1,2 PROVIDE A 2" X 18" GALV 16 G.. "Z" BAR ONEACH END 6" W/4 # 12 SHEET METAL SCREW BRACE HOOD TO THE WALL STUD.   OF M E T A L C O M P L I A N C E W I T H T A B L E 6 - 1 & 6 - 2 . TH E D U C T O R D U C T F I T T I N G S H A L L B E C O N S T R U C T E D 16 G A U G E C A R B O N S T E E L W E L D G R E A S E D U C T . EF 2 PROVIDE "X' BRACE WIRE # 12 ALL 4 SIDE MAKE-UP AIR UNIT SIDE DISCHARGE CHAMPION # SEE PLANS MUA 1, 2 PROVIDE "X' BRACE WIRE # 12 ALL 4 SIDE (E) ROOF JOIST 2 X 10X 21' D.F. @16" 2 #1/2" X 3" LAG SCREW TO SECURE EACH END. 6 TACK WELD TO THE MAKE UP AIR AT LESS 6" L. ANGLE 16 GA. GALV. ANGLE 2 X 10 SOLID BLKG EX I S T I N G W A L L 2 X 10 SOLID BLKG (E) ROOF JOIST 2 X 10X 18' D.F. @16" (E) ROOF JOIST 2 X 10X 21' D.F. @16" SIMPSON LU210 SIMPSON LU210 2 X 10 SOLID BLKG SIMPSON LU210 2 X 10 SOLID BLKG SIMPSON LU210 (E) ROOF JOIST 2 X 10X 21' D.F. @16"2 X 10 SOLID BLKG SIMPSON LU210  (E) TYPE "X" GYP. CEILING (E) TYPE "X" GYP. CEILING(E) TYPE "X" GYP. CEILING    • The damaged section should be removed by cuttingthe steel banding or removing the clips holding it in place. • A new section of the same dimension should be cutfrom a roll of 3M Fire Barrier Duct Wrap 15A, either24 in. (60,9 cm) or 48 in. (121 cm) wide. • The new section should be placed and fittedensuring the same overlap that existed previously. • The steel banding should be placed around thematerial and tensioned so as to sufficiently hold the3M Fire Barrier Duct Wrap 15A in place. •If the blanket has not been damaged but the foilhas ripped, seal the rips with aluminum foil tape. 8. Purchase Information3M Fire Barrier products are available through a network of nationwide distributors. For information onwhere to buy, go to www.3m.com/firestop. 9. Safe Handling InformationConsult Material Safety Data Sheet prior tohandling and disposing of 3M Fire Barrier DuctWrap 15A. Figure 2 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Access Door System 1. Access Hole 2.1/4 in. (6 mm) Dia. All Threaded Rods 3.Access Cover - 16 Gauge 4.Insulation Pins - Welded 5.First Layer 3M Fire Barrier Duct Wrap 15A Cut Same Size As Cover 6.Second Layer 3M Fire Barrier Duct Wrap 15A with 1 in. (25mm) Overlap On All Sides 7.Speed Clips 8.Aluminum Tape Covering All Exposed Edges 9.Spool Pieces For Threaded Rods 10.1/4 in. (6mm) Diameter Wing Nuts System integrity is limited by quality of installation. Figure 3 3M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems 4-1/2 inch (11,4 cm) Concrete Floor or Wall 1.Floor/Ceiling or Wall Assembly 2.Duct 3A.One Layer 3M Fire Barrier Duct Wrap 15A 3B Banding or Pinning 3C.Packing Material 3D.3M Fire Barrier 1000 N/S, 1003 S/L or 2000+ Silicone Sealant For Wall Assembly Apply Sealant To Both Sides of Wall System integrity is limited by quality of installation. Warranty and Limited Remedy. This product will be free from defects in material and manufacture for a period of ninety (90) days from date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR MERCHANTIBILITY ORFITNESS FOR A PARTICULAR PURPOSE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user’s method of application. If this 3M product is proved to be defective within the warranty period stated above, your exclusive remedy and3M’s sole obligation shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the product. Limitation of Liability. Except where prohibited by law, 3M will not be liable for any loss or damages arising from the use of this 3M prod- uct, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Printed in U.S.A. MCS 205630© 3M 2001 98-0400-5066-2 (Nov. 2001) Consumer Safety and Light Management Department 3M Center 223-2N-21St. Paul, MN 55144-1000(800) 328-1687 3M ICC-ES ESR-1255 points. Insulated cup-head pins can be used at thesame spacing requirements of the insulation pins. NOTE: Support hangar systems do not need to bewrapped provided the hangar rods are at least aminimum of 3/8 in. (9,53 mm) diameter and spaced amaximum of 60 in. (152 cm) on center along thelength of the duct. Use a minimum 2 in. x 2 in. x1/4 in. (50 mm x 50 mm x 6,35 mm) steel angle steelsupport channel or SMACNA equivalent supportsystem. Access Door Installation (See Figure 2)Four galvanized steel threaded rods, 1/4 in. diameter(6,35 mm) by 4-1/2 in. to 5 in. long (114 mm to127 mm) are welded to the duct at the corners of thedoor opening. Four steel tubes, each 3 in. (76 mm)long, are placed over the rods to act as protection forthe 3M Fire Barrier Duct Wrap 15A when fasteningthe door. Four insulation pins are welded to the doorpanel for installation of the blanket. One layer of 3MFire Barrier Duct Wrap 15A is cut approximately thesame size as the access panel and impaled over theinsulation pins on the panel. It is essential that thislayer fit tightly against the wrap surrounding theaccess door opening with no through openings. Asecond layer of 3M Fire Barrier Duct Wrap 15A is cutso as to overlap the first layer by a minimum of 1 in.(25,4 mm). The second layer is impaled over the pinsand both layers are locked in place with galvanized speed clips. Pins that extend beyond the outer layerof 3M Fire Barrier Duct Wrap 15A shall be turneddown to avoid sharp points on the door. The insulated door panel is placed over the threadedrods and held in place with washers and wing nuts.The details are shown in Figure 2. Penetrations (See Figure 3)When the duct penetrates a fire rated wall, ceiling orfloor, an approved firestop system must be employed.Figure 3 illustrates a typical condition. To firestop the wrapped duct, follow the installationparameters detailed in the following Omega PointLaboratories, Inc. systems: FS 557 W, FS 558 F, FS 559 W, FS 560 F, FS 561 F, FS 562 W, FS 563 W, FS 578 F, FS 579 W. Other ApplicationsMore details on the installation of the product can be found in the 3M Product Data and InstallationInstruction Manual (98-0400-5054-8). 7. MaintenanceNo maintenance is required when installed in accordance with the 3M Installation Instructions.Once installed, if any section of the 3M Fire BarrierDuct Wrap 15A is damaged so that the blanket isdamaged, the following procedures will apply: Figure 13M Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to CombustiblesTelescoping Wrap Technique With Banding For Ducts 24 inches (60,9 cm) or Less 1.One Layer 3M Fire Barrier Duct Wrap 15A 2.Steel Banding 1/2 in. (13 mm) Wide Min. Typical 3.3 in. (76 mm) Min. Longitudinal Overlap 4.3 in. (76 mm) Min. Perimeter Overlap System integrity is limited by quality of installation. Telescoping Overlap Wrap Option Cross Sectional View Checkerboard Overlap Wrap Option Cross Sectional View Butt Joint With Collar Option Cross Sectional View International Mechanical CodeStandard Building Code SBCCI ES Compliance Report 2132This is only a partial list of code compliance. For thelatest code and approval information go towww.3m.com/firestop or speak to your authorized 3Mdistributor or sales representative at (800) 328-1687. 6. Installation Techniques3M Fire Barrier Duct Wrap 15A system should beinstalled in accordance with the following installation instructions. Material and Equipment •3M Fire Barrier Duct Wrap 15A blanket, 1-1/2 in.(38 mm) thick, 24 in. (60 cm) or 48 in. (121 cm)wide, 20 ft. (609 cm) standard length. The 48 in.(121 cm) wide blanket helps to minimize waste. • Aluminum foil tape.• Minimum 3/4 in. (19 mm) wide filament tape.• Carbon steel or stainless steel banding material,minimum 1/2 in. (12,7 mm) wide, minimum 0.015 in. (0,38 mm) thick, with steel banding clips. • Hand banding tensioner, crimping tool, and banding cutter.• Minimum 12 gauge copper-coated steel insulationpins; galvanized steel or stainless speed clips, minimum1-1/2 in. (38 mm) square or 1-1/2 in. (38 mm) dia.round, or equivalent sized insulated cup-head pins;capacitor discharge stud gun. • Access door hardware: four galvanized steel threadrods, 1/4 in. (6 mm) diameter by 4-1/2 in. to 5 in.long (114 mm to 127 mm) with 1/4 in. (6 mm) wingnuts and 1/4 in. (6 mm) washers: 4 in. (102 mm)long steel hollow tubing to fit threaded rods. • Minimum 4.0 lb. (1,8 kg) density mineral wool orscrap pieces of 3M Fire Barrier Duct Wrap 15A. •3M Fire Barrier 1000 N/S, 1003 S/L or 2000+ Silicone Sealant. Storage: The 3M Fire Barrier Duct Wrap 15A and 3MFire Barrier 1000 N/S, 1003 S/L and 2000+ SiliconeSealants must be stored in a dry warehouse environment. Pallets should not be stacked. Preparatory Work: 3M Fire Barrier Duct Wrap 15A isinstalled with common tools, such as knives, bandersand capacitor discharge guns for applying insulationpins. In order to install the duct firestop system, thesurfaces of all the openings and penetrating itemsneed to be clean, dry, frost free and free of dust. Method: To minimize waste, 3M Fire Barrier DuctWrap 15A material should be rolled out tautly beforemeasuring. General instructions for installing the 3MFire Barrier Duct Wrap 15A include a one-layer wrapconstruction applied directly to the duct. The 3M FireBarrier Duct Wrap 15A blanket is wrapped around theperimeter of the duct and is cut to a length to overlapitself not less than 3 in. (76 mm). The overlap madeby adjacent blankets forms the “longitudinal” overlap.Aluminum foil tape is used to seal all cut edges of theblanket and any tears in the foil scrim. There are three (3) approved installation techniques for installing the 3M Fire Barrier Duct Wrap 15A (See Figure 1): 1. Telescoping 3 in. (76 mm) Overlap WrapWith the telescoping overlap wrap method, eachblanket overlaps one adjacent blanket, and eachblanket has one edge exposed and one edge coveredby the next blanket as shown in Figure 1. The visibleedges of the perimeter overlaps all point in the same direction. 2. Checkerboard 3 in. (76 mm) Overlap WrapWith the 3 in. (76 mm) checkerboard overlap wrapmethod, blankets with both edges exposed alternatewith blankets with covered edges, as shown in Figure1. The visible edges of the perimeter overlapsalternate their directions and appear on every other blanket. 3. Butt Joint With CollarWith the butt joint and collar method, adjacent blankets are butted tightly together and 6 in. (152 mm)wide collar of 3M Fire Barrier Duct Wrap is centeredover the joint, overlapping each blanket by3 in. (76 mm) minimum as shown in Figure 1. In all three overlap techniques the perimeter overlapcan occur at any location on the duct. The blanket is mechanically attached to the duct bysteel banding or by welded insulation pins and clips for all three installation methods listed above. For Banding Only (See Figure 1)Filament tape can be used to temporarily hold theblanket in place until the banding is applied. The steelbanding is applied around the duct 1-1/2 in. (38 mm)from each edge of the blanket, and maximum10-1/2 in. (26,7 cm) centers. The banding is placedaround the material and tightened so as to sufficientlyhold the 3M Fire Barrier Duct Wrap 15A in placeagainst the duct, compressing the foil but not cutting the foil. Additional Pinning to Prevent Sagging of theWrap: For Ducts 24 in. (60 cm) and larger in width,additional pins are needed to support the blanket on the bottom horizontal surface and on the outside faceof a vertical duct run. Space pins a maximum of10-1/2 in. (26,7 cm) apart in the direction of theblanket width, and a maximum of 12 in. (30 cm) apartin the direction of the blanket length. Refer toparagraph below for more information on MechanicalFastening with Pins. For Mechanical Fastening with Pins OnlyInsulation pins are welded to the duct in the centersof the overlaps a minimum of 1-1/2 in. (38 mm) fromeach edge of the blanket, and spaced a maximum of10-1/2 in. (26,7 cm) on center along perimeteroverlap, and a maximum of 10-1/2 in. (26,7 mm) oncenter along longitudinal overlaps. The blanket isimpaled over the pins and held in place by galvanizedspeed clips. Insulation pins that extend beyond theblanket wrap shall be turned down to eliminate sharp 1. Product Description3MTM Fire Barrier Duct Wrap 15A is a fire resistantwrap consisting of a patented inorganic blanketencapsulated with a scrim-reinforced foil. It is used tofire rate commercial kitchen grease ducts and is aproven alternative to 1 or 2 hour fire resistant ratedshaft enclosures. This non-asbestos wrap contains asafer fiber construction* and installs easily because ofits high flexibility and strength.3M Fire Barrier DuctWrap 15A is the thinnest standard, single layer fireresistant wrap that has passed the UL1978 test whichsimulates a grease duct fire. With its excellentinsulating capabilities, it is an ideal choice for tightspaces because it protects combustible constructionsat zero clearance to the overlap or collar. 3M Fire Barrier 1000 N/S, 1003 S/L and 2000+ Silicone Sealants used in combination 3M Fire Barrier DuctWrap 15A provide an effective firestop when the ductpenetrates fire rated walls and floors. Features• Thinnest, standard one layer wrap for grease ductsrated as a shaft alternative per UL 1978 • Zero clearance to the overlap or collar forcongested spaces • High flexibility for installation ease• Foil encapsulated with unique center overlap seamfor blanket protection, less dust, and high wrapstrength • Widest range of penetration seal systems • Safer fiber construction* *Has been demonstrated to be soluble in the lungs according to EU guidelines 67/548/EWG, Note Q for bio persistence. 2. Applications3M Fire Barrier Duct Wrap 15A is an ideal fireresistive enclosure for commercial kitchen greaseducts. It is a proven performance alternative to a 1 or 2 hour fire resistant rated shaft enclosures andprovides zero clearance to combustible constructionat overlap or collar.3M Fire Barrier 1000 N/S, 1003 S/L or 2000+ Silicone Sealant is used in combinationwith 3M Fire Barrier Duct Wrap 15A to firestop theduct when the duct penetrates fire rated floors and walls. 4. Typical Physical Properties Blanket Color:gray/greenWeight: 1.38 lbs./sq. ft. (6.73 kg/sq. m) 5. Performance3M Fire Barrier Duct Wrap 15A has been tested inaccordance with the following: ASTM C 411 ASTM E 119ASTM C 518 ASTM E 136ASTM E 84 ASTM E 814UL 1978 (Sections 12 & 13) Surface Burning Characteristics (ASTM E 84)Foil Encapsulated Blanket:Flame Spread: 0Smoke Developed: 0 Blanket:Flame Spread: 0Smoke Developed: 0 For technical data and properties of 3M Fire Barrier 1000 N/S, 1003 S/L and 2000+ Silicone Sealants seeseparate product data sheets available from your 3Mrepresentative. Code Compliance3M Fire Barrier Duct Wrap 15A complies withrequirements of the following codes:BOCA ES Compliance Report 2161 NFPA 96, 1998 Edition Standard Mechanical Code Fire Barrier Duct Wrap 15A Commercial Kitchen Grease Duct Fire Protection System Product Data 3 Compliance 1998 Edition Complies with InternationalMechanical Code Complies with StandardMechanical Code 3. Availability Product Unit Size Units/Wt./ctn. ctn. 3M Fire Barrier Roll 1.5 in.x 24 in. x 20 ft.1 53 lbs.Duct Wrap 15A (38mm x 60,9cm x 609 cm)24 kg 3M Fire Barrier Roll 1.5 in. x 48 in. x 20 ft.1 106 lbs.Duct Wrap 15A (38mm x 121 cm x 609 cm)48 kg Thermal Conductivity Temperature OF (OC)btu•in./(hr.•ft2•F)500 (260)0.4171000 (537)0.9221500 (815)1.691800 (982)2.27 Grease Duct Listings Fire Enclosure System Omega Point Lab. Design Nos. Resistive Duct System Through- Rating PenetrationSystem 1 or 2 hours GD 532 F FS 557 WGD 538 F FS 558 F FS 559 W FS 560 F FS 561 F FS 562 W FS 563 W FS 578 F FS 579 W 1 layer of 3M Fire Barrier Duct Wrap 15A , 3 in. (76 mm) perimeter and longitudinal overlaps M NFPA 96 PLASTER ON METAL LATH ON METAL STUD SEE ARCHITECTURE PLAN FOR DETAIL RESEARCH REPORT:RR25765 (CSI#07815)                                                                                                      1 4824 ND-2 13' 0.00"600 Deg.3575 -0.583"3575 430 SS Where Exposed ALONE ALONE HOOD NO.TAG MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM TOTAL EXH. CFM RISER(S) WIDTH LENG.DIA.CFM S.P. TOTAL SUPPLY CFM HOOD CONSTRUCTION HOOD CONFIG. END TO END ROW 178712"12" -0.583"178712"12" 1 Captrate Solo Filter 9 20"16"4 L55 Series E26 NO NO 653 LBS HOOD NO.TAG FILTER(S) TYPE QTY.HEIGHT LENGTH LIGHT(S) QTY.TYPE WIRE GUARD UTILITY CABINET(S) LOCATION FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WGHT 1 FINISHED BACK- ISL/REV INSTALL 156.00" Long HOOD NO.TAG OPTION 13' 0.00"Nom./13' 0.00"OD 48" 3" 39"78"39" 2 1/4"75 3/4"75 3/4" NOTE: Additional hanging angles provided for hoods 12' and longer. U.L. Listed L55 Series E26 Canopy Light Fixture - High Temp Assembly 11" 12" 12" 11" 12" 12" 3" INTERNAL STANDOFF GREASE DRAIN WITH REMOVABLE CUP 4" EXHAUST RISER HANGING ANGLE L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) 23.5% OPEN STAINLESS STEEL PERFORATED PANEL ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 6" 2 3/4" 16" 18" EQUIPMENT BY OTHERS 48.0" MAX 80" AFF REFERENCE 24" NOM. 54" IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK 4.166"Shelf With 2.25"Condensate MUA 2.25" 2.25" 2.25" 4.166" IN THE FOLLOWING LOCATIONS FOR WALL CANOPIES HANGING ANGLES WILL BE LOCATED REAR FROMDIM Only Back OnlyExhaust MUA With Wall Exhaust HOOD STYLE DIM DIM 2.25" 2.25" 2.25" 2.25" Hood) Hood) 2.25" 2.25" (24" High FRONT FROM (30" High FRONT FROM GREASE CUP WILL BE SUPPORTED BY TWO STUDS ON THE INSIDE WALL OF THE HOOD. THE GREASE WILL DRAIN THROUGH A CONCEALED GREASE TROUGH AND INTO THIS REMOVEABLE/CLEANABLE CUP. MC IntertekIT AN S TED ION L SIAT RE S I S T A N C E ( i n . H 2 0 ) CAPTRATE R AIRFLOW (cfm) 0.2 0.4 400 0 0 200 600 800 1000 0.6 0.8 1.2 1 1.4 RESISTANCE VS. AIRFLOW 1.6 2" Captrate Grease-Stop Solo FilterRR Captrate Grease-Stop Solo Filter NOTE- Exhaust Collar Must be Factory Installed. If A Different Size Or Location is Required, Please Note Change On Submittal. Rear Discharge Is Available. Contact CaptiveAire For Possible Locations. 1 CORE Protection 0 0 Fire Cabinet Left Left FIRE SYSTEM NO. Tag TYPE SIZE FLOW POINTS INSTALLATION SYSTEM LOCATION ON HOOD 1 SC Electrical 2.000 CaptiveAire Systems FIRE SYSTEM NO. TAG TYPE SIZE SUPPLIED BY1 0 - 0 - 100-BW 2x4 Blank Plate for J-Box 0 - 0 - 12-F28021-005360 Duct Fire Thermostat. NO, Close on temp rise at 360°F. 0 - 0 - 59361-1/2 2x4 Extension Ring 0 - 0 - SLPCON-03FT Supervised Loop Connection Kit. Contains the parts needed to connect the supervised loop between End to End hoods with less than a 2' gap. Kit contains 5 Feet of Black MG wire, 5 Feet of Tan MG wire, 3 Feet of Flexible Conduit, and two 7/8" connectors. 0 - 0 - SLPCON-20FT Supervised Loop Connection Kit. Contains the parts needed to connect the supervised loop between hoods with upto 19' gap. Kit contains 22 Feet of Black MG wire, 22 Feet of Tan MG wire, 20 Feet of Flexible Conduit, and two 7/8" connectors. 34 - 34 - A0019852 24VDC or 120VAC Single Action Manual Actuation Device (Push/Pull Station) With Protective Cover, One (1) Normally Open Contact ADDITIONAL PARTS TO BE DETERMINED... 3 3 3 1 1 1 0 0 0 0 0 0 FIRE SYSTEM NO. TAG KEY NUMBER - PART DESCRIPTION QTY. BY FACTORY QTY. BY DIST. 1 NCA16FA 3575 1.350 1137 1.500 0.4550 1 208 7 142 13.4 FAN UNIT NO. TAG FAN UNIT MODEL #CFM ESP.RPM H.P.B.H.P.Ø VOLT FLA WEIGHT (LBS.)SONES 1 1 - Grease Box FAN UNIT NO. TAG OPTION (Qty. - Descr.) 1 YES FAN UNIT NO. TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SUPPLY SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 # 1 41 LBS Curb 26.500"W x 26.500"L x 20.000"H Vented Hinged NO.ON FAN WEIGHT ITEM SIZE - WEATHERPROOF DISCONNECT - GREASE CLASSIFICATION TESTING - HIGH HEAT OPERATION 300°F (149°C) DAMAGED TO ANY EXTENT THAT COULD CAUSE 15 MINUTES WITHOUT THE FAN BECOMING AT 600°F (316°C) FOR A PERIOD OF WHILE EXHAUSTING BURNING GREASE VAPORS EXHAUST FAN MUST OPERATE CONTINUOUSLY ABNORMAL FLARE-UP TEST WOULD CAUSE UNSAFE OPERATION. DETERIORATING EFFECTS TO THE FAN WHICH THERMAL EQUILIBRIUM, AND WITHOUT ANY UNTIL ALL FAN PARTS HAVE REACHED WHILE EXHAUSTING AIR AT 300°F (149°C) EXHAUST FAN MUST OPERATE CONTINUOUSLY NORMAL TEMPERATURE TEST - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH 24 3/4 21 14 7/8 33 3/4 30 1/2 2 23 AN UNSAFE CONDITION. FEATURES: - RESTAURANT MODEL - ROOF MOUNTED FANS - UL705 AND UL762 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) GREASE DRAIN 3" FLANGE 21 21 ROOF OPENING DIMENSIONS 20 GAUGE CONSTRUCTION STEEL 20" 23" 23" VENTED CURB EXAMPLE: 7/12 PITCH = 30° SLOPE PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. SPECIFY PITCH: 0" 0° 12" FANS #1, #2 - NCA14FA EXHAUST FAN OPTIONS GREASE BOX                                                                                                      1 4824 ND-2 13' 0.00"600 Deg.3575 -0.583"3575 430 SS Where Exposed ALONE ALONE HOOD NO.TAG MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM TOTAL EXH. CFM RISER(S) WIDTH LENG.DIA.CFM S.P. TOTAL SUPPLY CFM HOOD CONSTRUCTION HOOD CONFIG. END TO END ROW 178712"12" -0.583"178712"12" 1 Captrate Solo Filter 9 20"16"4 L55 Series E26 NO NO 653 LBS HOOD NO.TAG FILTER(S) TYPE QTY.HEIGHT LENGTH LIGHT(S) QTY.TYPE WIRE GUARD UTILITY CABINET(S) LOCATION FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WGHT 11' 0.00"Nom./11' 0.00"OD 54" 16" 22" 8" 12" 28" 44" 8" 12" 28" 44" 8" 12" 28" 3" 66"66" 12" Ø16" U.L. Listed L55 Series E26 Canopy Light Fixture - High Temp Assembly 3" INTERNAL STANDOFF GREASE DRAIN WITH REMOVABLE CUP 4" EXHAUST RISER HANGING ANGLE L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) 23.5% OPEN STAINLESS STEEL PERFORATED PANEL ATTACHING PLATES SUPPLY RISER WITH VOLUME DAMPER 6" 2 3/4" 16" 18" EQUIPMENT BY OTHERS 48.0" MAX 80" AFF REFERENCE 24" NOM. 54" IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK 4.166"Shelf With 2.25"Condensate MUA 2.25" 2.25" 2.25" 4.166" IN THE FOLLOWING LOCATIONS FOR WALL CANOPIES HANGING ANGLES WILL BE LOCATED REAR FROMDIM Only Back OnlyExhaust MUA With Wall Exhaust HOOD STYLE DIM DIM 2.25" 2.25" 2.25" 2.25" Hood) Hood) 2.25" 2.25" (24" High FRONT FROM (30" High FRONT FROM GREASE CUP WILL BE SUPPORTED BY TWO STUDS ON THE INSIDE WALL OF THE HOOD. THE GREASE WILL DRAIN THROUGH A CONCEALED GREASE TROUGH AND INTO THIS REMOVEABLE/CLEANABLE CUP. MC IntertekIT A N S TED ION L SIAT RE S I S T A N C E ( i n . H 2 0 ) CAPTRATE R AIRFLOW (cfm) 0.2 0.4 400 0 0 200 600 800 1000 0.6 0.8 1.2 1 1.4 RESISTANCE VS. AIRFLOW 1.6 2" Captrate Grease-Stop Solo FilterRR Captrate Grease-Stop Solo Filter NOTE: MODEL ND-2 IS AN ETL LISTED EXHAUST HOOD ETL LISTING IS 200 CFM/FT (600 DEGREES) Q = ETL LISTING * 11'0" = 2200 CFM < 2750 CFM (DESIGN) MODEL ND-2 IS ETL LISTED WITH 1 EX RISER UP TO 16' ACETATE-BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECUREMENT TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED SPECIFICATIONS THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE-ENGINEERED WITH UNDERWRITERS LABORATORIES, INC. (UL) THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT-OFF APPLICATIONS. THE EXTINGUISHING AGENT SHALL BE A POTASSIUM CARBONATE, POTASSIUM OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIQUID AGENT HANDLING AND USAGE. THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACCORDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM. THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. 1 NCA16FA NCA16FA 3025 1.350 1112 1.500 1 240 7 184 13.4 FAN UNIT NO. FAN UNIT MODEL #MODEL TAG CFM ESP.RPM H.P.Ø VOLT FLA WEIGHT (LBS.)SONES 1 1 - Grease Box FAN UNIT NO. OPTION (Qty. - Descr.) 1 YES FAN UNIT NO. FAN UNIT TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SUPPLY SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT 1 # 1 41 LBS Curb 26.500"W x 26.500"L x 20.000"H Vented Hinged NO.ON FAN WEIGHT ITEM SIZE - WEATHERPROOF DISCONNECT - GREASE CLASSIFICATION TESTING - HIGH HEAT OPERATION 300°F (149°C) DAMAGED TO ANY EXTENT THAT COULD CAUSE 15 MINUTES WITHOUT THE FAN BECOMING AT 600°F (316°C) FOR A PERIOD OF WHILE EXHAUSTING BURNING GREASE VAPORS EXHAUST FAN MUST OPERATE CONTINUOUSLY ABNORMAL FLARE-UP TEST WOULD CAUSE UNSAFE OPERATION. DETERIORATING EFFECTS TO THE FAN WHICH THERMAL EQUILIBRIUM, AND WITHOUT ANY UNTIL ALL FAN PARTS HAVE REACHED WHILE EXHAUSTING AIR AT 300°F (149°C) EXHAUST FAN MUST OPERATE CONTINUOUSLY NORMAL TEMPERATURE TEST - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TO DISCONNECT SWITCH 28 24 16 1/2 39 3/8 33 3/4 2 22 5/8 GREASE DRAIN AN UNSAFE CONDITION. FEATURES: - RESTAURANT MODEL - ROOF MOUNTED FANS - UL705 AND UL762 DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) 19 1/2 39 3" FLANGE 24 24 ROOF OPENING DIMENSIONS 20 GAUGE CONSTRUCTION STEEL 20" 26 1/2" 26 1/2" VENTED CURB FAN #1 NCA16FA - EXHAUST FAN OPTIONS GREASE BOX                                                                                                      1 6024 VHB-PSP-F CAPTIVEAIRE 5' 0"700 DEG II N/A 175 875 4"12"875 1114 -0.116"700 430 SS 100%ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP TOTAL SUPPLY CFM HOOD CONSTRUCTION HOOD CONFIG END TO END ROW 1 2 L55 SERIES E26 NO NO 258 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT 1 Front 60"14"6"MUA 12"28"699 0.159" HOOD NO TAG POS LENGTH WIDTH HEIGHT TYPE RISER(S) WIDTH LENG DIA CFM SP 5' 0"NOM./5' 0.00"OD. 60" 14" 30" 7" 12" 28" § 30"30" 30" Ø12" U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY.1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM)STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEELFLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNERHANGING ANGLE (WEIGHT BEARING ANCHOR POINTFOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPIGRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5(MINIMUM) STEEL FLAT WASHER. FULL LENGTHHANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). FULL LENGTH HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5(MINIMUM) STEEL FLAT WASHER. SUPPLY PLENUM HANGING ANGLE(WEIGHT BEARING ANCHOR POINT FOR SUPPLYPLENUM). SUPPLY PLENUM HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR PSP HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) SEE HOOD TABLE. EXHAUST RISER. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). 23.5% OPEN STAINLESS STEEL PERFORATED PANEL. ATTACHING PLATES. SUPPLY RISER WITH VOLUME DAMPER. 6" 2 3/4" 14" 18" EQUIPMENT BY OTHERS. 80" 24" NOM. 60" IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS.                                                                                                                        BOLT 3/8"Ø MACHINE TYPICAL ROUND DUCT STRAP ROUND DUCT MAX. LOAD EACH 420 600 2"x16 GA. 1/8"STL.x2" HANGER/LBS. 45°SEE SCHEDULE FOR SIZE. EACH MAX. LOAD STRAP OR RECT. DUCT TYPICAL SQUARE DUCT MAX. OF #10 SELF TAPPING RECTANGULAR DUCT (TYPICAL)12" O.C. MAX. 3. 2. 1. NOTE: 4201"X 18 GA.P/2 =72 PERIMETER/IN.HANGER/LBS. OF LESS THAN 6 SQUARE FEET AND ROUND DUCTS LESS THAN 28 INCHES IN DIAMETER. BRACING NOT REQUIRED FOR RECTANGULAR DUCTS WITH CROSS SECTIONAL AREAS FOR TRANSVERSE AND LONGITUDINAL BRACING FOLLOW "SMACNA". NO BRACING REQUIRED IF DUCT IS SUSPENDED 12 INCHES OR LESS IN LENGTH. GALVANIZED SHEETMETAL STRAP DUCT HANGER 5'-0" O.C.- 2"x2"x1/4" DIAGONAL BRACE 16'-0"O.C. MAX. STRUCTURE SPACING BOTH SIDES. FOR CONNECTION TO WOOD UP TO 20" DIAMETER/INCHES 21" TO 36" S.M.S. EQUALLY SPACED ROD 3/8 IN(680# MAX) 4. MAXIMUM 8 FEET ON CENTER SPACING PER CMC CHAPTER 6. BOLT 3/8"Ø MACHINE NOTE: DETAIL APPLICABLE FOR DUCTWORK ONLY, CONNECTION TO WOOD DETAIL "A" OR NEW 2x RAFTER/ STRUCTURAL MEMBER WOOD AT EACH END HANGER WIRE MIN. 3 TIGHT TURNS TYPICAL BLOCKING OR NEW 2x RAFTER/ JOIST/RAFTER BLOCKING MIN. 4 TIGHT TURNS AT EACH END BRACING WIRE TYPICAL THREAD EMBED. 1/4"Ø SCREW EYE W/ FULL SPLAYED 12 GAUGE ATTACHMENT TO WOOD HANGER WIRE EMBED 1 1/4" MIN. VERTICAL 12 GAUGE ATTACHMENT TO WOOD HANGER WIRE MEMBER WOOD STRUCTURAL 3" MAX. HANGER STRAP ATTACHMENT TO WOOD SCREWS x 2" MIN. 2-#8 WOOD HANGER STRAP SIMPSON A35 WITH 1/2" MAX. LENGTH SCREWS TO PLYWOOD 3" M I N . 2x RAFTERS 24" ON CENTER BOLT 1/2"Ø THRU OR LONGITUDINAL BRACES VERTICAL, DIAGONAL SIMPSON A35 EACH SIDE- ROOF RAFTERS 4x BLOCKING WITH EXISTING RAFTER DEPTH TO MATCH EACH END CONNECTION TO WOOD DETAIL "B" (FOR P/2 GREATER THAN 72) 3" MIN. 2" MIN. THREADED TEE WITH DIRECTION OF FLOW FOOT DOWN IN SLOPE 1/8" PER 5" MIN. PROVIDE DRAIN NUT IN NOTE: BOTTOM OF P-TRAP 3" WITH S.S. CLAMPS NEOPRENE TUBING REMOVABLE CAP LOOSE CAP 3/4" TYPICAL HVAC UNIT, S.M.D. 2" x 4" REDWOOD BLOCK PRESSURE TREATED WITH APPROVED MATERIAL FOR OUTDOOR INSTALLATION- SECURE REDWOOD TO ROOF WITH (2)3/8"Øx3" LAG BOLTS EXISTING ROOF SEALANT UNDER BLOCK TO PREVENT SEEPAGE OF WATER INTO ROOF ONE-HOLE UNISTRUT PIPE STRAP (SIZE AS REQUIRED) P-1000 UNISTRUT 1/4"x3/4" GALVANIZED WOOD SCREW REFRIGERANT PIPE WALL CONDENSATE LINE BY PLBG CONTRACTOR, LAVATORY/ SINK SEE FLOOR PLAN TAILPIECE FROM PLBG. FIXTURE SEE PLBG DWGS APPROVED FITTING BY PLBG CONTRACTOR SEE PLBG DWG'S FINISHED FLOOR SLOPE                                                                                                                                                                                                                                                                                                                PIPE MATERIALS SERVICES LOCATION MATERIAL JOINING METHOD REMARKS DOMESTIC COLD & HOT WATER UNDERGROUND RIGID COPPER( TYPE K)BRAZED NOT TO EXCEED 20 OF I PERCENT JOINT FITTINGS. SHOULD STREET PRESSURE EXCEED 80 PSI, A PRESSURE REDUCING VALVE ASSEMBLY SHALL BE INSTALLED. NO JOINTS SHALL BE ALLOWED UNDER BUILDING SLAB. GATE VALVES SHALL BE BRONZE WITH ENDS TO SUITE PIPE, NONRISING STEM FOR 150 PSI WORKING PRESSURE. ABOVE UNDERGROUND RIGID COPPER( TYPE L)SOLDERED SANITARY WASTE SEWER UNDERGROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS ABOVE GROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS SANITARY WASTE VENT ABOVE GROUND CAST IRON SOIL PIPE & FITTINGS OR OTHER APPROVED MATERIAL HUBLESS LOW PRESSURE GAS UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED PROVEIDE APPROVED GAS PRESSUSRE REGULATORS. NATURAL GAS RIGHT AND LEFT HAND NIPPLES AND COUPLINGS SHALL BE NEW BLACK IRON, UNIONS SHALL NOT BE USED EXCEPT AT UNITS AND VAVLES. ABOVE UNDERGROUND SCHEDULE 40 BLACK STEEL WELDED ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY ABS PIPE MAY BE USED WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY PLUMBING ABBREVIATIONSMEP COMPONENT ANCHORAGE NOTE PIPING SYSTEM BRACING NOTE GENERAL NOTES FIXTURE CONNECTION SCHEDULE (BRANCH SIZES) MISC. EQUIPMENT SCHEDULE MISC. EQUIPMENT SCHEDULE DOMESTIC WATER CALCULATION DOMESTIC WATER PIPING SIZING PLUMBING LEGEND                                                                                                                                                                                                          RICEwarmer OVEN OVEN PA S S - T H R U SH E L F SO D A D I S P E N S E R WIT H I C E B I N TV WAITING AREA PA S S - T H R U SH E L F ICE MAKER(FLAKER) ICE BIN AIR C U R T A I N undercounterdishwasher IC E B I N EM P L O Y E E L O C K E R S RICEcooker WAITING BENCH WA I T I N G B E N C H BABY CHANGING STATION ELEC. PANEL FS TV TV TV TV TV TV TVTV TV TV STAIRS TO EXISTINGMEZANNINE AREA MO P S I N K TV LEGEND FLOOR PLAN (HOT & COLD) 3/16"=1'-0"                                                                                                      RICEwarmer OVEN OVEN ELEC. PANEL PA S S - T H R U SH E L F SO D A D I S P E N S E R WIT H I C E B I N TV WAITING AREA PA S S - T H R U SH E L F ICE MAKER(FLAKER) ICE BIN AIR C U R T A I N undercounterdishwasher IC E B I N EM P L O Y E E L O C K E R S RICEcooker WAITING BENCH WA I T I N G B E N C H BABY CHANGING STATION ELEC. PANEL FS TV TV TV TV TV TV TVTV TV TV STAIRS TO EXISTINGMEZANNINE AREA MO P S I N K TV TABLE 1014.3.6 GRAVITY GREASE INTERCEPTOR SIZING FLOOR PLAN (WASTE & VENT) 3/16"=1'-0"                                                                                                      RICERRICERICECCIIRIRCCCCCCIIIIIICCwarmererrrwarmer OVEN OVEN ELEC. PANEL PA S S - T H R U SH E L F SO D A D I S P E N S E R SO D A D I S P E N S E R WIT H I C E B I N TV WAITING AREA PA S S - T H R U SH E L F ICE MAKER(FLAKER) ICE BIN AIR C U R T A I N undercounterdishwasher IC E B I N EM P L O Y E E L O C K E R S CCCCCm CEERICCkerercookk WAITING BENCH WA I T I N G B E N C H WA I T I N G B E N C H BABY CHANGING STATION ELEC. PANEL I FS TV TV TVVT TV TVV TVTTVTTTTVTVTTTTTTVTVTTTTTVTTVVTT TVTV TV TV STAIRS TO EXISTINGMEZANNINE AREA A ww R MO P S I N K K TVTTTTTTTTTTTVVVVV N FLOOR PLAN (GAS) 3/16"=1'-0" 92'-05 8" 25'-81116"                                                                                                    