Loading...
HomeMy WebLinkAbout1107 S Baldwin Ave #B - 2025 - Japan MartX#.# X X-# Water ClosetWC WD Wood TypicalTYP Top Of CurbTC TW Top Of Wall Top of Paraphet Top Of GradeTG TOP RD Roof Drain SCH Schedule Specification Similar SheetSHT SIM SPEC RM Room RequiredREQ'D STRUCTStructural HeightHT Property LinePL MTL MECH Mechanical Metal Not To Scale Natural GradeNG NTS On CenterOC LWC Light Weight Concrete Air ConditioningHVAC WIC Walk In Closet GRID LINES DETAIL REFERENCE WINDOW DOOR SECTION CUT INTERIOR ELEVATION REF. DETAIL ENLARGEMENT REF. DETAIL REFERENCE REVISION NUMBER SMOKE DETECTOR NOTE REFERENCE FAN OUTLET W/GROUND-FAULT CIRCUIT-INTERRUPTER DUPLEX RECEPTACLE OUTLET "HALF-HOT" OUTLET SPLIT-WIRED RECEPTACLE THREE-WAY SWITCH SINGLE-POLE SWITCH CEILING MOUNTED JUNCTION BOX COMPUTER DATA OUTLET TELEVISION / CABLE OUTLET INCANDESCENT LIGHTING CEILING MOUNTED INCANDESCENT LIGHTING WALL MOUNTED FLUORESCENT LIGHTING CEILING RECESSED TELEPHONE OUTLET AluminumAL BLDG BALC Balcony Building CONC Concrete Double ContinuousCONT DBL CLR CLO CLG CL Center Line Ceiling Closet Clear Down Spout DownDN DS DIM Dimension FL Floor Face of Wall (Finish) Face of StudFOS FOW GEN GYP Gypsum Board General Fire Extinguisher Foot or FeetFT FX FG FF FD EXT Exterior Floor Drain Finish Floor Finish Grade Fire Hose Cabinet Fire HydrantFH FHC EXIST EQ Equal Existing Elevation Electrical DrawingDWG ELEC ELEV Square FeetSF xx xx SD TV S3 S J GFI RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt COVER SHEET G000 SHEET INDEXPROJECT DATA VICINITY MAP JAPAN MART SUBMITTAL LOG ZONING NOTES LEGAL DESCRIPTION PUBLIC WORKS NOTES CONSTRUCTION NOTES 1107 S. BALDWIN AVE., UNIT B ARCADIA, CA 91007 LEGEND BUILDING CODE SITE CONSULTANTS 1. 1. A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIRED BEFORE THE BUILDING DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OF PUBLIC WORKS DEPARTMENT INSPECTION, IF ANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK, CURB AND GUTTER, AND ALLEY/STREET PAVEMENT WILL BE REQUIRED. ADDITIONALLY, IF EXISTING UTILITIES INFRASTRUCTURE ARE DEEMED SUBSTANDARD, A NEW 1-INCH WATER SERVICE, WATER METER BOX, SEWER LATERAL AND/OR CLEANOUT WITH BOX AND LID WILL BE REQUIRED. 100% OF THE COST SHALL BE BORNE BY THE PROPERTY OWNER (MUNICIPAL CODES 14.24.020 AND 14.08.030). SAID DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE MADE AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR. CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE PUBLIC RIGHT OF WAY AT ALL TIMES DURING THE CONSTRUCTION PROJECT. A STOP WORK NOTICE MAY BE ISSUED FOR ANY DAMAGE OR UNMAINTAINED PORTION OF THE PUBLIC RIGHT OF WAY. 1. CONTRACTOR TO PROVIDE PAINT/COLOR SAMPLE FOR ARCHITECT/OWNER'S APPROVAL PRIOR PAINTING. 2. CONTRACTOR TO PROVIDE STAIR SHOP DRAWINGS FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 3. CONTRACTOR TO PROVIDE GUARDRAIL/HANDRAIL SHOP DRAWINGS FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 4. CONTRACTOR TO PROVIDE ROOFING SAMPLE FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 5. CONTRACTOR TO PROVIDE DOOR/WINDOW SHOP DRAWINGS FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 6. CONTRACTOR TO PROVIDE LIGHT SWITCH SAMPLE FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 7. CONTRACTOR TO PROVIDE TILE SAMPLE FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 8. CONTRACTOR TO PROVIDE CABINET SHOP DRAWINGS FOR ARCHITECT/OWNER'S APPROVAL PRIOR INSTALLATION. 1. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 2. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND HANDRAILS OR ANY COMBINATION THEREOF SHALL NOT EXCEED 42 INCHES FROM EXISTING GRADE PRIOR TO CONSTRUCTION WITHIN THE REQUIRED FROM SETBACK AREA(S) 3. ALL SETBACKS SHALL BE MEASURED FROM PROPERTY LINE TO FACE OF FINISH. DEFERRED SUBMITTAL DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN CHECK OR APPROVAL BY THE CITY. 1. ANSUL SYSTEM OF TYPE I HOOD 2. FIRE SUPRESSION SYSTEM 3. STOREFRONT SIGNAGE APPLICABLE CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ENERGY CODE CALIFORNIA BUILDING STANDARDS CODE (TITLE 24)12 CALIFORNIA RETAIL FOOD CODE (CAL CODE)45 PROJECT DESCRIPTION ADDRESS ASSESSOR'S PARCEL NUMBER OWNER NAME OWNER ADDRESS OWNER CONTACT & PHONE # CONSTRUCTION TYPE NUMBER OF STORIES EXISTING BUILDING HEIGHT PROPOSED SETBACKS REAR SETBACK SIDE SETBACK OCCUPANCY FIRE SPRINKLERS LOT AREA PARKING SPACE TENANT IMPROVEMENT 3,770 SF MINI MARKET FEATURING A RETAIL AREA, A POP-UP SHOP SPACE, A SMALL SEATING AREA, A RESTROOM, STORAGE, A KITCHEN, A DRINK BAR,AND A SERVICE COUNTER FOR FAST FOOD ORDERS AND PICKUP. 1107 S. BALDWIN AVE., UNIT B ARCADIA, CA 91007 5783-008-045 EMPIRE ELEPHANT USA 25 E FOOTHILL BLVD., ARCADIA, CA 91006 ALAN PUN -(626)895-5780 V-A 1 24'-0" FT. MAX. MEASURED FROM E.G. (E) NO CHANGE (E) NO CHANGE (E) NO CHANGE B & M SPRINKLED (EXISTING) EXISTING NO CHANGE EXISTING NO CHANGE TAG DESIGN WORKS ARCHITECT: JOHNNY LU, AIA, LEED AP, C30396 PROJECT MANAGER: WING HO, ASSOC. AIA, LEED AP 411 E. HUNTINGTON DR., SUITE 308 ARCADIA, CA 91006 T: 626.446.5300 EMAIL: WHO@TAGDESIGNWORKS.COM MEP ENGINEER MWQ ENGINEERING MOTAZ QUDAH, PE 5UPPER NEWPORT PLAZA DR, SUITE #202 T: 562 413 9495 EMAIL: MOTAZ@MWQENG.COM STRUCTURAL ENGINEER WPH ENGINEERING LLC. STRUCTURAL DESIGN CONSULTANTS 411 HUNTINGTON DR SUITE #313, ARCADIA, CA 91006 T: 562.277.5649 EMAIL: WPH@WPHENGINEERING.COM *TR=PARCEL MAP AS PER BK 102 P 23 OF P M LOT 1 SHEET NUMBER SHEET NAME 00-GENERAL G000 COVER SHEET G101 FIRE, LIFESAFETY AND CODE SIGNAGE PLAN G201 GENERAL NOTES G301A CALIFORNIA GREEN CHECKLIST G301B CALIFORNIA GREEN CHECKLIST G301C CALIFORNIA GREEN CHECKLIST G401 ACCESSIBILITY NOTES G403 ACCESSIBILITY DETAILS G404 ACCESSIBILITY DETAILS G501 SPECIFICATIONS G502 SPECIFICATIONS G503 SPECIFICATIONS G504 SPECIFICATIONS G505 SPECIFICATIONS 01-ARCH .AD101 DEMOLITION PLANS .AD102 DEMOLITION PLANS .AS101 SITE PLAN A101 FLOOR PLAN A102 REFLECTED CEILING PLAN A103 ROOF PLAN A301 BUILDING SECTIONS A401 INTERIOR ELEVATIONS A402 INTERIOR ELEVATIONS A403 INTERIOR ELEVATIONS A404 INTERIOR ELEVATIONS A405 EXTERIOR ELEVATIONS A406 INTERIOR DETAILS A510 INTERIOR PARTITION FRAMING DETAILS A511 INTERIOR PARTITION TYPES AND DETAILS A515 TYPICAL CEILING DETAILS A601 DOOR SCHEDULES & DETAILS A701 ENLARGED TOILET ROOM PLAN AND ELEVATIONS A801 3D PERSPECTIVES (FOR REFERNACE ONLY) A802 3D PERSPECTIVE (FOR REFERANCE ONLY) A803 3D PERSPECTIVE (FOR REFERANCE ONLY) FS101 EQUIPMENT PLAN AND SCHEDULE 01.1- WALK-IN FRIDGE 1 OF 4 WALK-IN FRIDGE SHOP DRAWING 2 OF 4 WALK-IN FRIDGE SHOP DRAWING 3 OF 4 WALK-IN FRIDGE SHOP DRAWING 4 OF 4 WALK-IN FRIDGE SHOP DRAWING 02-STRUCT S0.1 GENERAL NOTES S1.0 FOUNDATION & ROOF/CEILING PLANS S2.0 ROOF FRAMING PLAN SD1 STRUCTURAL DETAILS SD2 STRUCTURAL DETAILS 03-MECH M-00 MECHANICAL LEAD SHEET M-01 MECHANICAL PLANS M-02 GREASE HOOD DETAILS M-03 GREASE HOOD DETAILS M-04 GREASE HOOD DETAILS M-05 GREASE HOOD DETAILS M-06 GREASE HOOD DETAILS M-07 GREASE HOOD DETAILS M-08 GREASE HOOD DETAILS M-09 GREASE HOOD DETAILS M-10 GREASE HOOD DETAILS M-11 GREASE HOOD DETAILS M-12 GREASE HOOD DETAILS M-13 ENERGY COMPLIANCE FORMS M-14 ENERGY COMPLIANCE FORMS M-15 ENERGY COMPLIANCE FORMS 04-PLUMB P-00 PLUMBING LEAD SHEET P-01 PLUMBING SITE PLAN P-02 PLUMBING FLOOR PLAN-WATER AND GAS P-03 PLUMBING FLOOR PLAN - SANITARY SEWER AND VENT P-04 PLUMBING ROOF PLAN 05-ELEC E0.0 ELECTRICAL SYMBOLS AND LEGENDS E1.0 ELECTRICAL POWER PLANS E2.0 LIGHTING PLAN E3.0 ONE LINE DIAGRAM AND LIGHTING SCHEDULE E4.0 PANEL SCHEDULES E5.0 EMERGENCY LIGHTING PHOTOMETRIC E6.0 TITLE 24 09/25/2025 BUILDING AND SAFETY (1ST) PLAN CHECK 09/25/2025 HEALTH DEPARTMENT (1ST) PLAN CHECK 11/03/2025 BUILDING AND SAFETY (1ST) PLAN CHECK 11/03/2025 HEALTH DEPARTMENT (1ST) PLAN CHECK OCCUPANT LOAD OCCUPANT LOAD CALCULATION PER TABLE 1004.5 ROOM # ROOM NAME AREA OCC. LOAD OCC. FACTOR OCC. LOAD RETAIL 1 ENTRY LOBBY 247 SF M 60 5 2 SEATING 100 SF A 15 8 6 KITCHEN 616 SF B 200 4 7 SUSHI PREP. AREA 234 SF B 200 2 8 WALK-IN FRIDGE 205 SF B - 0 9 RETAIL 823 SF B 60 14 10 TOILET 65 SF B - 0 11 TOILET 64 SF B - 0 12 OFFICE/STORAGE 241 SF B 150 2 13 POP-UP 289 SF M 60 5 2885 SF 40 CAFE 3 WAITING 245 SF A 15 19 4 GRAM BAR 177 SF B 200 1 5 SERVICE COUNTER 151 SF B 200 1 573 SF 21 SPECIAL INSPECTION AND QUALITY ASSURANCE SEE SHEET S0.1 GENERAL NOTES "SPECIAL INSPECTION AND QUALITY ASSURANCE" SECTION AND ALSO SEE THE SPECIAL INSPECTION TABLE UNDER "STATEMENT OF SPECIAL INSPECTION". WH A B C D C L R ø 5 ' - 0 "CLR ø 5' - 0" CLR ø 5' - 0" 234 SF SUSHI PREP. AREA 7 205 SF WALK-IN FRIDGE 8 616 SF KITCHEN 6 241 SF OFFICE/STORAGE 12 65 SF TOILET 10 64 SF TOILET 11 100 SF SEATING 2 245 SF WAITING 3 247 SF ENTRY LOBBY 1 823 SF RETAIL 9 289 SF POP-UP 13 151 SF SERVICE COUNTER 5 177 SF GRAM BAR 4 2' - 0" B-CAFE 778 SF OCC LOAD= 21 M-RETAIL 2,680 SF OCC LOAD= 40 1 0 4 ' D I A G O N A L D I S T A N C E / 3 = 3 5 ' < 4 5 ' 45 ' EX I T EX I T EX I T EG R E S S T R A V E L D I S T A N C E = 8 8 F T < 1 0 0 F T EGRESS TRAVEL DISTANCE =45 FT ACCESSIBLE CHECKOUT COUNTER. TOP OF COUNTER SHALL BE 34" MAX AF.F., ACCESSIBLE CHECKOUT COUNTER. TOP OF COUNTER SHALL BE 34" MAX AF.F., EXIT #2 -6'-0" OPENING 20 OCCUPANTS 360 MAXIMUM OCCUPANTS EXIT #1 -3'-0" OPENING 24 OCCUPANTS 180 MAXIMUM OCCUPANTS EGRESS TRAVEL DISTANCE =46 FT EXIT #3 -3'-0" OPENING 16 OCCUPANTS 180 MAXIMUM OCCUPANTS FIRE EXTINGUISHER FIRE EXTINGUISHER FIRE EXTINGUISHER 30"x48" 30"x48" 30 " x 4 8 " FIRE EXTINGUISHER ADA SEATING ADA SEATING .. . EGRESS TRAVEL DISTANCE =60 FT EXIT EX I T EXIT 4' - 3 1 / 2 " 30 " x 4 8 " ADA SEATING 4' - 0"4' - 0" 5' - 0" 30"x48" 30 " x 4 8 " 30 " x 4 8 " 30 " x 4 8 " 4' - 0" 3' - 8 1 / 2 " 4' - 8 1 / 2 " 4' - 5 " 4' - 8 1/2" 312 INDICATES 5'-0" CLEAR TURN AROUND SPACE FOR ACCESSIBILITY INDICATES 36" WIDE PATH OF TRAVEL EXIT ROUTE PORTABLE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A:10B:C GC SHALL VERIFY TYPE AND EXACT LOCATION WITH FIRE MARSHAL EXIT ILLUMINATED EXIT LIGHT W/ BATTERY BACK UP -REFER TO ELECTRICAL DRAWINGS FOR MORE DETAILS AND TO REFLECTED CEILING PLAN FOR ADDITIONAL DIRECTIONAL EXIT SIGNS 1 HR RATED WALL 1/4" = 1'-0"1EGRESS PLAN RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt FIRE, LIFESAFETY AND CODE SIGNAGE PLAN G101 REQUIRED: (B + M MIX): ONE MEN’S (1 WC, 1 LAV.) AND ONE WOMEN’S (1 WC, 1 LAV.) (1) SERVICE SINK (JANITOR’S CLOSET) (1) DRINKING FOUNTAIN OR BOTTLED WATER DISPENSER PROVIDED : (2) ACCESSIBLE SINGLE OCCUPANT UNISEX FACILITY WITH TOTAL OF (2WC,2LAV& 1 RINALS) (1) DRINKING FOUTAINS AND (1)SERVICE SINK PLUMBING FIXTURES CALCULATION (2022 CPC CHAPTER 4) CAFE: (BUSINESS) SERVICE COUNTER 151SF/200=1 WATING 245SF/15=17 KITCHEN AREA 117SF/50=3 21/2=11 MAN/11 WOMEN RETAIL: SETTING 100SF/30=4 KITCHEN AREA (F): 616+234/ 50 =17 STORAGE: 205SF / 4000 = 1 OFFICE:241 SF/150= 2 RETAIL:247SF+823SF+289SF/ 100= 14 TOTAL OCCUPANT LOAD: 38 = 19 MEN / 19 WOMEN * PER 2022 CALIFORNIA PLUMBING CODE 422.2 EXCEPTION #3: IN BUSINESS AND MERCANTILE OCCUPANCIES WITH A TOTAL OCCUPANT LOAD OF 50 OR LESS INCLUDING CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGNED FOR USE BY NO MORE THAN ONE PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES. ** CPC 2022 415.2 DRINKING FOUNTAIN ALTERNATIVES WHERE FOOD IS CONSUMED INDOORS, WATER STATIONS SHALL BE PERMITTED TO BE SUBSTITUTED FOR DRINKING FOUNTAINS. BOTTLE FILLING STATIONS SHALL BE PERMITTED TO BE SUBSTITUTED FOR DRINKING FOUNTAINS UP TO 50 PERCENT OF THE REQUIREMENTS FOR DRINKING FOUNTAINS. DRINKING FOUNTAINS SHALL NOT BE REQUIRED FOR AN OCCUPANT LOAD OF 30 OR LESS. PLUMBING FIXTURES CALCULATIONS *M RETAIL V-A 56,000 *B CAFE V-A 72,000 WITHOUT AREA INCREASE OCCU. TYPE FUNCTION BUILDING TYPE MAX. AREA ALLOWED NOTE TABLE 506.2: ALLOWABLE AREA FACTOR *M RETAIL V-A 50FT *B CAFE V-A 50 FT WITHOUT AREA INCREASE OCCU. TYPE FUNCTION CONST. TYPE MAX. H.T. ALLOWED NOTE TABLE 504.3: ALLOWABLE BUILDING HEGIHT *M RETAIL V-A 3 *B CAFE V-A 3 WITHOUT AREA INCREASE OCCU. TYPE FUNCTION CONST. TYPE MAX. STORY ALLOWED NOTE TABLE 504.4 - ALLOWABLE NUMBER OF STORIES *PER CBC 303.1.1 SMALL BUILDINGS AND TENANT SPACES, A BUILDING OR TENANT SPACE USED FOR ASSEMBLY PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY. BUILDING AREA AND H.T. ANALYSIS (CBC 506) BUILDING AREA = 1,213 + 690 SF COVERED PATIO = 1,903 SF < 72,000 ALLOWED OCCUPANT LOAD CALCULATION PER TABLE 1004.5 ROOM # ROOM NAME AREA OCC. LOAD OCC. FACTOR OCC. LOAD RETAIL 1 ENTRY LOBBY 247 SF M 60 5 2 SEATING 100 SF A 15 8 6 KITCHEN 616 SF B 200 4 7 SUSHI PREP. AREA 234 SF B 200 2 8 WALK-IN FRIDGE 205 SF B - 0 9 RETAIL 823 SF B 60 14 10 TOILET 65 SF B - 0 11 TOILET 64 SF B - 0 12 OFFICE/STORAGE 241 SF B 150 2 13 POP-UP 289 SF M 60 5 2885 SF 40 CAFE 3 WAITING 245 SF A 15 19 4 GRAM BAR 177 SF B 200 1 5 SERVICE COUNTER 151 SF B 200 1 573 SF 21 LEGEND - - OFFICE - - 999 000 SF 01 A 2 A-3 PH-00 - - A - - - - - - -- 7.05 - - - - 18 A999 - - - SECTION NUMBER SHEET NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER ELEVATION NUMBER ROOM TAG FIRE EXTINGUISHER IN RECESSED CABINET WORK POINT, DATUM POINT DOOR NUMBER. ROOM NUMBER ELEVATION NUMBER SHEET NUMBER GRID REFERENCE SEE ELECTRIC DRAWINGS ILLUMINATED EXIT SIGN REVISION NUMBER ELEVATION SHOWN WALL TYPES-REFER TO SHEET A511 CONSTRUCTION KEYNOTES DEMOLITION KEYNOTES INTERIOR ELEVATION MATERIALS FIXTURE SCHEDULE REFER TO ELEVATION SHEET COLOR & MATERIAL REFERENCE EQUIPMENT SCHEDULE CEILING TYPE AND CEILING HEIGHT WINDOW NUMBER - ANNOTATION SYMBOLS DA HS VCR J J SAK v SD T P M M M WAP CAM CR FLOOR WALL DURESS ALARM SWITCH WALL MOUNTED HORN / STROBE DOOR BELL VIDEO RECORDER SECURITY ALARM KEYPAD SMOKE DETECTOR JUNCTION BOX IN WALL JUNCTION BOX ABOVE CEILING AUDIBLE ALARM VISUAL ALARM EXHAUST FAN CARD READER THERMOSTAT PANIC BUTTON MOTION SENSOR IN WALL MONITOR MOTION SENSOR ON CEILING CAMERA WITH DATA OUTLET WIRELESS ACCESS POINT WITH DATA OUTLET DEDICATED DUPLEX ELECTRICAL OUTLET TELE-POWER POLE W/ 4 ELECTRICAL OUTLETS VOICE & DATA OUTLET w/ TERMINATION FACEPLATE DATA OUTLET w/ TERMINATION FACEPLATE VOICE OUTLET w/ TERMINATION FACEPLATE 220V. ELECTRICAL OUTLET QUADRUPLEX ELECTRICAL OUTLET THREE-WAY LIGHT SWITCH DUPLEX ELECTRICAL OUTLET LIGHT SWITCH DEDICATED QUADRUPLEX ELECTRICAL OUTLET d.d. d.d. RECESSED ELECTRICAL PANEL V ELECTRICAL LEGEND CONCRETE MASONRY BLOCK GYPSUM BOARD STUCCO / PLASTER RIGID INSULATION FINISHED WOOD -AS NOTED CONTINUOUS WOOD BATT INSULATION EARTH PLYWOOD CONCRETE METAL WOOD BLOCKING E.F.I.S. MATERIAL LEGEND SUSPENDED TILE CEILING AND GRID CEILING ACCESS PANEL DUPLEX RECEPTACLE, 20A, 125V UNLESS NOTED OTHERWISE QUAD RECEPTACLE, 20A, 125V UNLESS NOTED OTHERWISE JUNCTION BOX CEILING MOUNTED LIGHT SPRINKLER HEAD CEILING FAN SMOKE DETECTOR EXIT SIGN EMERGENCY LIGHT 2x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN SPRINKLER RISER GAS METER 1x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN STRIP LIGHT FIXTURE-SEE ELECTRICAL PLAN CARBON MONOXIDE DETECTOR RECESSED LIGHT FIXTURE SUPPLY AIR GRILLE RETURN AIR GRILLE SUPPLY AIR GRILLE WALL MOUNTED LIGHT FIXTURE UNIT PANELBOARD, FLUSH MOUNTED, RATED AS NOTED DATA OUTLET TELEVISION OUTLET VOICE & DATA OUTLET J C F S TYPICAL PLAN SYMBOLS (DEMOLITION) SUSPENDED TILE CEILING AND GRID CEILING ACCESS PANEL DUPLEX RECEPTACLE, 20A, 125V UNLESS NOTED OTHERWISE QUAD RECEPTACLE, 20A, 125V UNLESS NOTED OTHERWISE JUNCTION BOX CEILING MOUNTED, PENDANT LIGHT SPRINKLER HEAD CEILING FAN SMOKE DETECTOR EXIT SIGN EMERGENCY LIGHT 2x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN SPRINKLER RISER GAS METER 1x4 LIGHT FIXTURE-SEE ELECTRICAL PLAN STRIP LIGHT FIXTURE-SEE ELECTRICAL PLAN CARBON MONOXIDE DETECTOR RECESSED LIGHT FIXTURE SUPPLY AIR GRILLE RETURN AIR GRILLE SUPPLY AIR GRILLE WALL MOUNTED LIGHT FIXTURE UNIT PANELBOARD, FLUSH MOUNTED, RATED AS NOTED DATA OUTLET TELEVISION OUTLET VOICE & DATA OUTLET GYPSUM BOARD CEILING J C F S TYPICAL PLAN SYMBOLS (NEW) A. GENERAL REQUIREMENTS 1. AIA DOCUMENT A201 -2007 GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION ARE HEREBY INCLUDED AS PART OF THE CONTRACT DOCUMENTS AND OWNER/CONTRACTOR AGREEMENT. 2. SOLELY AS A CONVENIENCE TO THE OWNER, THE ARCHITECT MAY INCLUDE DOCUMENTS PREPARED BY CERTAIN CONSULTANTS (OR INCORPORATE THE RECOMMENDATIONS OF SAID CONSULTANTS IN DOCUMENTS PREPARED BY THE ARCHITECT) WITHIN THE SET OF DOCUMENTS ISSUED BY THE ARCHITECT BEING EXPRESSLY UNDERSTOOD THAT, BY SAID ISSUANCE, THE ARCHITECT ASSUMES NO LIABILITY FOR THE SERVICES OF SAID CONSULTANTS NOT UNDER CONTRACT TO THE ARCHITECT. 3. THE ENTIRE WORK SHALL BE WARRANTED AGAINST DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER. THE WARRANTY SHALL SPECIFICALLY PROVIDE THAT ALL DEFECTS IN MATERIAL AND WORKMANSHIP APPEARING DURING THE WARRANTY PERIOD, AS DETERMINED BY THE ARCHITECT, WILL BE REMEDIED TO THE SATISFACTION OF THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL SECURE AND FURNISH TO THE OWNER AS A CONDITION PRECEDENT TO FINAL ACCEPTANCE AND PRIOR TO APPLICATION FOR PAYMENT, ALL WRITTEN GUARANTEES AND WARRANTIES, A LIST OF NAMES, ADDRESSES, AND TELEPHONE NUMBERS OF ANY AND ALL SUB-CONTRACTORS USED FOR THE CONSTRUCTION AND SERVICES. 4. THESE PLANS AND RELATED DOCUMENTS MUST BE AVAILABLE AT THE JOB SITE AT ALL TIMES & BE AVAILABLE DURING ANY INSPECTION ACTIVITY PER C.B.C. 5. WORK WITHIN THE AREA BOUNDARIES INDICATED IN THE PROJECT DOCUMENTS SHALL COMPLY WITH ALL APPLICABLE BUILDING CODE REGULATION AND ORDINANCE REQUIREMENTS. OCCUPANTS ADJACENT TO THE PROJECT ARE BOUNDARIES SHALL CONTINUE UNINTERRUPTED OCCUPANCY DURING CONSTRUCTION OF THE PROJECT. 6. 6. CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY TO CONTINUOUSLY AND NOT BE LIMITED TO NORMAL HOURS: AND THE CONTRACTOR SHALL DEFEND: INDEMNIFY AND HOLD THE OWNER & ARCHITECT HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. 7. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE RULES AND REGULATIONS OF THE LANDLORD IN THE PERFORMANCE OF THE WORK. A COPY OF THE RULES AND REGULATIONS ARE AVAILABLE FROM THE LANDLORD UPON REQUEST. 8. CONTRACTORS INSURANCE REQUIREMENTS PER LANDLORD RULES AND REGULATIONS AND TENANT REQUIREMENTS. EACH POLICY OF INSURANCE SHALL NAME THE LANDLORD AND TENANT, SUCCESSORS, AND ASSIGNS WITHOUT ADDITIONAL CHARGE. THE CONTRACTOR SHALL CERTIFY TO THE OWNER THAT HE HAS OBTAINED SIMILAR CERTIFICATES OR MEMORANDUM EVIDENCE FORM EACH OF THE SUBCONTRACTORS BEFORE THEIR WORK COMMENCES. EACH SUBCONTRACTOR MUST BE COVERED BY INSURANCE OF THE SAME CHARACTER, NAMING THE CONTRACTOR AN THE OWNER AS ADDITIONAL INSUREDS. 9. CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID TO FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS. 10. THE CONTRACTOR SHALL EXAMINE THE DRAWINGS AND SPECIFICATIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. 11. THE CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 12. THE CONTRACTOR SHALL INSPECT EXISTING CONDITIONS, INCLUDING ELEMENTS SUBJECT TO MOVEMENT OR DAMAGE DURING DEMOLITION, CUTTING AND PATCHING. AFTER UNCOVERING THE WORK, INSPECT CONDITIONS AFFECTING INSTALLATION OF NEW WORK. IF UNCOVERED CONDITIONS ARE NOT AS ANTICIPATED, IMMEDIATELY NOTIFY THE ARCHITECT AND SECURE NEEDED DIRECTIONS. DO NOT PROCEED IN AREAS OF DISCREPANCY UNTIL ALL SUCH DISCREPANCIES HAVE BEEN FULLY RESOLVED. 13. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED PROTECTION PRIOR TO CUTTING, INCLUDING BUT NOT NECESSARILY LIMITED TO SHORING, BRACING AND SUPPORT TO MAINTAIN STRUCTURAL INTEGRITY OF THE EXISTING WORK. THE CONTRACTOR SHALL CAREFULLY PROTECT ALL EXISTING FINISHES TO REMAIN SUCH AS WALL COVERING, FLOORING, CEILING AND DOORS. HE SHALL PERFORM ALL CUTTING AND DEMOLITION BY METHODS WHICH WILL PREVENT DAMAGE TO OTHER PORTIONS OF THE WORK AND WILL PROVIDE PROPER SURFACES TO RECEIVE INSTALLATION OF NEW WORK. PERFORM FITTING AND ADJUSTMENT OF PRODUCTS TO PROVIDE FINISHES INSTALLATION COMPLYING WITH THE SPECIFIED TOLERANCES AND FINISHES. 14. THE ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY ACTION TAKEN BY ANYONE ON THE PROJECT IF THAT PERSON HAS KNOWLEDGE OF ANY DISCREPANCY, OMISSION, OR AMBIGUITY IN THE DRAWINGS OR SPECIFICATIONS UNTIL THE ARCHITECT HAS BEEN NOTIFIED, CORRECTED THE DISCREPANCY, MADE THE INCLUSION OR MORE CLEARLY EXPLAINED THE INTENT OF THE DRAWINGS OR SPECIFICATIONS. 15. GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE COORDINATION OF THE VARIOUS TRADES PERFORMING THE WORK. CONTRACTOR SHALL SUBMIT FOR REVIEW COMPLETE, COMPOSITE COORDINATION SHOP DRAWINGS ILLUSTRATING THE EXTENT AND POSITION OF EACH COMPONENT OF THE WORK AS TO AVOID CONFLICT AND TO MAINTAIN REQUIRED SERVICE ACCESS AND CODE REQUIRED CLEARANCES. NO WORK SHALL BE PERFORMED UNTIL REFERENCED COORDINATION SHOP DRAWINGS HAVE BEEN REVIEWED WITH NO EXCEPTION TAKEN. 16. DO NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. 17. THE CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF DRAWINGS AT THE JOB SITE FOR USE IN MAKING "RECORD DRAWINGS." ANY REVISIONS SHALL BE NOTED THEREON AND SUBMITTED TO THE ARCHITECT AT THE COMPLETION OF THE JOB PER THE PROJECT MANUAL. PROVIDE A COPY FOR THE OWNER PER CONSTRUCTION DOCUMENTS. 18. THE ARCHITECT IS AUTHORIZED TO ORDER MINOR CHANGES DURING THE COURSE OF THE WORK WHICH WILL NOT INVOLVE EXTRA COST OR TIME AND WHICH ARE CONSISTENT WITH THE CONTRACT DOCUMENTS. 19. THE OWNER AND/OR ARCHITECT RESERVE THE RIGHT TO HAVE TESTS MADE WHEN DEEMED NECESSARY. SHOULD THE ARCHITECT ORDER SPECIAL TESTING OR INSPECTION OF A QUESTIONABLE PART OF THE WORK WHICH REVEALS DEFECTS NOT IN CONFORMITY WITH THE CONTRACT DOCUMENT, THE CONTRACTOR SHALL PAY THE COST OF SUCH SPECIAL TESTING OR INSPECTIONS INCLUDING THE ARCHITECTS EXTRA SERVICES MADE NECESSARY THEREBY. OTHERWISE THE OWNER SHALL BEAR THE COST. A. TESTS SHALL BE MADE IN ACCORDANCE WITH RECOGNIZED STANDARDS BY COMPETENT, INDEPENDENT TESTING LABORATORY. ANY MATERIAL FOUND DEFECTIVE OR NOT IN CONFORMITY WITH THE SPECIFICATION STANDARDS SHALL BE PROMPTLY REPLACED OR REPAIRED AT THE EXPENSE OF THE CONTRACTOR. SAMPLES REQUIRED FOR TESTING WILL BE FURNISHED BY THE CONTRACTOR AND SELECTED AS DIRECTED BY THE ARCHITECT. 20. THE CONTRACTOR SHALL RETAIN ALL STORED ITEMS IN AN ORDERLY ARRANGEMENT ALLOWING MAXIMUM ACCESS, NOT IMPEDING WALKWAYS AND PROVIDING THE REQUIRED PROTECTION OF MATERIALS. 21. THE CONTRACTOR SHALL MAINTAIN THE PROJECT AREA IN A NEAT AND ORDERLY CONDITION AT ALL TIMES, NOT ALLOWING THE ACCUMULATION OF SCRAP, DEBRIS, WASTE MATERIAL AND OTHER ITEMS NOT REQUIRED FOR CONSTRUCTION OF THIS WORK. 22. THE CONTRACTOR SHALL CONDUCT THE FINAL CLEANING OF ALL AREAS AFFECTED BY THIS WORK. VISUALLY INSPECT ALL INTERIOR SURFACES AND REMOVE ALL TRACES OF SOIL, WASTE MATERIAL, SMUDGES AND OTHER FOREIGN MATTER. REMOVE ALL TRACES OF SPLASHED MATERIALS FROM ADJACENT SURFACES. REMOVE ALL PAINT DROPPINGS, SPOTS, STAINS AND DIRT FROM FINISHED SURFACES. USE ONLY THE SPECIFIED CLEANING MATERIALS AND EQUIPMENT. CLEAN AND POLISH ALL GLASS EITHER INSTALLED OR AFFECTED BY THIS WORK. 23. THE CONTRACTOR SHALL PROVIDE AND COORDINATE THE EXACT DIMENSIONS, SIZES AND POSITIONS OF ALL OPENINGS IN FLOOR AND WALL CONSTRUCTION NECESSARY FOR THE INSTALLATION OF THE WORK. CONFIRM LOCATION WITH THE PROJECT MANAGEMENT TEAM PRIOR TO BEGINNING THE WORK. 24. CONTRACTOR SHALL XRAY/RADAR TO LOCATE ALL REINFORCEMENT AND UTILITIES IN STRUCTURAL CONCRETE SLABS, BEAMS, WALLS ETC. PRIOR TO DRILLING, CUTTING OR INSTALLING FASTENERS. 25. PENETRATIONS INTO AND THROUGH PARTITIONS CONTAINING SOUND INSULATION BATTS SHALL BE SEALED WITH PERMANENT RESILIENT SEALANT SPECIFIED FOR THAT PURPOSE. ELECTRICAL DEVICES, RECESSED CABINETS, ETC. SHALL BE SEALED, LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN THE INTEGRITY OF THE ACOUSTICAL ASSEMBLY. ALL PENETRATIONS THROUGH MATERIALS PROVIDING FIRE PROTECTION SHALL BE SEALED TO MAINTAIN REQUIRED FIRE RATING. 26. ALL PIPING AND DUCT WORK, VALVES, DAMPERS, CONTROLS AND TERMINATIONS SHALL BE INSTALLED AT LOCATIONS WHICH PROVIDE SAFE, DIRECT AND EASY ACCESS. PROVIDE ACCESS DOORS AT WALLS AND CEILINGS FOR ACCESS WHERE REQUIRED, WHETHER SHOWN ON THE DRAWINGS OR NOT, WITH NO ADDITIONAL COST TO THE OWNER. 27. ALL ATTACHMENTS TO AND PENETRATIONS THROUGH CONCRETE NOTED ON THE DRAWINGS TO BE WATERPROOFED SHALL BE MADE PRIOR TO APPLICATION OF THE WATERPROOFED MATERIAL. 28. CUTTING, BORING, SAW-CUTTING OR DRILLING THROUGH THE NEW OR EXISTING STRUCTURAL ELEMENTS TO BE DONE ONLY WHEN SO DETAILED IN THE DRAWINGS OR REVIEWED AND ACCEPTED BY THE STRUCTURAL ENGINEER. 29. PENETRATION THROUGH FIRE RATED FLOORS AND WALLS SHALL BE PROVIDED IN ACCORDANCE WITH THE CBC SECTIONS 709.6 AND 714 SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE PROVIDED FOR REVIEW BY INSPECTION AUTHORITIES. SUBSTITUTIONS OF OR REVISIONS OR ADDITIONS TO APPROVED SYSTEMS SHALL BE SUBMITTED TO THE INSPECTOR OF RECORD AND THE FIRE DEPARTMENT FOR FIELD REVIEW AND APPROVAL. 30. THE CONTRACTOR SHALL NOT INTERRUPT EXISTING UTILITIES SERVING EXISTING FACILITIES, EXCEPT WHEN AUTHORIZED IN WRITING BY THE OWNER AND ALL AUTHORITIES HAVING JURISDICTION. PROVIDE TEMPORARY SERVICES DURING CONSTRUCTION ACTIVITIES ACCEPTABLE TO LANDLORD AND GOVERNING AUTHORITIES. 31. THE WORK SHALL INCLUDE ALL REMOVALS NOT SPECIFICALLY INDICATED ON DRAWINGS BUT NECESSARY FOR THE COMPLETION OF WORK. 32. THE CONTRACTOR SHALL KEEP ALL EXITS READILY ACCESSIBLE AND UNOBSTRUCTED AT ALL TIMES. B. DEFINITIONS 1. WHEN A DETAIL IS IDENTIFIED AS TYPICAL. THE CONTRACTOR SHALL APPLY THIS DETAIL TO EVERY LIKE CONDITION WHETHER OR NOT THE REFERENCE IS REPEATED IN EVERY INSTANCE. WHEN A NOTE IS IDENTIFIED AS TYPICAL (TYP.), THE CONTRACTOR SHALL APPLY THIS NOTE TO EVERY LIKE CONDITION (REPRESENTED GRAPHICALLY OR NOT) WHETHER OR NOT THE REFERENCE IS REPEATED IN EVERY INSTANCE. 2. "SIMILAR" INDICATES COMPLETE SYSTEM AND COMPONENTS SHALL BE PROVIDED COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. AS REQUIRED INDICATES COMPONENTS REQUIRED TO COMPLETE THE NOTES, SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS, SHALL BE PROVIDED. 4. ALIGN INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE & PLUMB RELATION TO ADJACENT MATERIALS. GENERAL NOTES C. PERMITS 1. OWNER WILL REIMBURSE CONTRACTOR FOR THE COST OF BUILDING PERMIT. COST OF ALL OTHER PERMITS BY CONTRACTOR. 2. COST FOR THE INSTALLATION OF THE TEMPORARY BARRICADE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL MAINTAIN BARRICADE DURING CONSTRUCTION AND REMOVE WHEN CONSTRUCTION IS COMPLETE. 3. SEPARATE PERMITS SHALL BE OBTAINED FOR PEDESTRIAN PROTECTION, DEMOLITION, PLUMBING, MECHANICAL ELECTRICAL, FIRE SPRINKLER, AND FIRE ALARM AS REQUIRED BY THE LOCAL GOVERNING AGENCIES OR FIRE SPRINKLER AND FIRE ALARM AGENCIES. THE COST FOR THE SEPARATE PERMITS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. COST FOR THIRD PARTY INSPECTIONS AND TESTING SHALL BE THE RESPONSIBILITY OF THE OWNER. ALL OTHERS ARE THE RESPONSIBILITY OF THE CONTRACTOR. D. DIMENSIONS 1. DIMENSIONS ARE INDICATED TO THE CENTERLINE OF THE STRUCTURAL GRID, FACE OF CONCRETE WALL, NOMINAL FACE OF CMU WALL, FACE OF SHEATHING AT EXTERIOR AND FACE OF STUD AT INTERIORS, AS SCHEDULED, UNLESS OTHERWISE NOTED. 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. 3. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 4. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR -AFF. 5. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC PANEL CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 6. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, CLEARANCE, AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND COMPONENTS. DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE DRAWINGS. 7. WHERE DIMENSIONAL DISCREPANCIES OCCUR, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY BEFORE PROCEEDING WITH THE WORK. E. TEMPORARY FACILITIES 1. THE CONTRACTOR SHALL MAKE ALL NECESSARY ARRANGEMENTS FOR CONSTRUCTION WATER, POWER, AND TOILET FACILITIES. 2. ALL COMBUSTIBLES CONSISTING OF BOXES, SCRAP LUMBER, ETC., ON THE CONSTRUCTION SITE SHALL BE CLEANED UP AND DISPOSED OF IN AN APPROVED MANNER ON A DAILY BASIS. 3. A MINIMUM OF ONE (1) 2A:10BC RATED EXTINGUISHER OR AS REQUIRED BY PUBLIC AGENCY HAVING JURISDICTION SHALL BE MAINTAINED AT THE JOB SITE. F. ACCESS DOORS & PANELS 1. CONTRACTOR SHALL PROVIDE ACCESS PANELS AS REQUIRED BY PLUMBING, FIRE SPRINKLER, MECHANICAL, ELECTRICAL AND OTHER INSTALLERS AS REQUIRED BY CODE. 2. PROVIDE RATED ACCESS PANEL @ ALL RATED WALL, FLOOR/CEILING, AND CEILING ROOF ASSEMBLIES. G. SPECIALTIES -FIRE EXTINGUISHERS 1. PROVIDE MIN. ONE (1) PORTABLE CLASS 2A: 10BC FIRE EXTINGUISHER. LOCATE WITHIN SEVENTY-FIVE (75) FEET FROM ANY POINT WITHIN THE TENANT SPACE. PROVIDE ADDITIONAL PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE DEPARTMENT FIELD INSPECTOR AND AS NOTED ON THE DRAWINGS. H. SIGNAGE 1. SIGN CONTRACTOR SHALL ACQUIRE SEPARATE BUILDING DEPARTMENT PERMITS FOR INSTALLATION OF ALL SIGNS AS REQUIRED BY LOCAL CODES. (N.I.C.). 2. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL BLOCKING, ELECTRICAL JUNCTION BOX(ES), AND ACCESS PANELS. COORDINATE LOCATION(S) WITH SIGN CONTRACTOR AND ARCHITECT. 3. ROOM SIGNAGE SHALL BE BY CONTRACTOR BY STATE AND/OR LOCAL CODES. I. FIRE ASSEMBLIES 1. FIRE RESISTIVE FLOOR CEILING OR ROOF CEILINGS ASSEMBLIES SHALL BE PROVIDED, CONSTRUCTED, AND / OR MAINTAINED IN ACCORDANCE WITH SECTION 712 OF THE CALIFORNIA BUILDING CODE. 2. SHAFT ENCLOSURES: OPENINGS THROUGH FLOORS SHALL BE ENCLOSED IN A SHAFT ENCLOSURE OF FIRE RESISTIVE CONSTRUCTION IN ACCORDANCE WITH SECTION 713 OF THE CALIFORNIA BUILDING CODE. 3. PROVIDE FIRE STOPPING AT ALL THROUGH PENETRATIONS IN FIRE RATED WALL ASSEMBLIES, FLOOR/ CEILING ASSEMBLIES, CEILING / ROOF ASSEMBLIES, ETC. ALL FIRESTOPPING ASSEMBLIES SHALL HAVE U.L. LISTING OR EQUAL AND MEET THE REQUIREMENTS OF CALIFORNIA BUILDING CODE SECTION 711 & 712. J. PLUMBING 1. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL NOTES. 2. AN APPROVED SEISMIC GAS SHUTOFF SHALL BE INSTALLED ON THE GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE GAS PIPES. 3. CONTRACTOR SHALL LABEL ALL SHUT OFF SUPPLY VALVES WITH THE AREAS/ITEMS IN WHICH THEY ARE SERVING. 4. WHERE IT HAS BEEN RECOMMENDED BY THE SOILS SURVEY REPORT TO PROVIDE PIPE PROTECTION FROM UNDERGROUND CORROSIVE SOIL(S), PIPES SHALL BE PROTECTED/ENCASED PER THE INSTALLATION/ENCASEMENT PORTIONS OF ASTM-74, ASTM D 2321 & AWWA C105 AS APPLIES. K. MECHANICAL 1. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL NOTES. 2. COMBINATION FIRE AND SMOKE DAMPERS SHALL BE PROVIDED WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR CEILINGS. CONTRACTOR SHALL PROVIDE REQUIRED CONSTRUCTION EVEN WHEN NOT SPECIFICALLY DETAILED. 3. CONTRACTOR SHALL UTILIZE BUILDING CONTRACTOR FOR STARTUP OF HVAC UNITS. L. FIRE SPRINKLERS (DESIGN BUILD) 1. THE BUILDING IS FULLY SPRINKLERED THROUGHOUT. THE DESIGN BUILD CONTRACTOR SHALL BE RESPONSIBLE FOR MODIFYING THE EXISTING SYSTEM TO ACCOMMODATE THE PROPOSED IMPROVEMENTS. 2. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE AUTOMATIC FIRE SPRINKLER TO GOVERNING AGENCIES FOR APPROVAL PRIOR TO WORK IN THE FIELD. SHOP DRAWINGS SHALL BEAR STAMPED APPROVALS FROM ALL AUTHORIZED AGENCIES AND BY ANY OTHER AGENCIES WHOSE APPROVALS ARE REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. 3. AUTOMATIC FIRE SPRINKLERS MUST BE IN FULL OPERATIONAL USE AND "ON" PRIOR TO FIXTURIZATION OF TENNANT'S LEASE SPACE. 4. ALL SPRINKLER HEADS IN GYPSUM BOARD CEILINGS SHALL BE FULLY RECESSED TYPE. ESCUTCHEON COLOR SHALL BE SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARD COLORS. 5. ALL SPRINKLER HEAD IN ACOUSTICAL CEILING TILE (OFFICE) SHALL BE SEMI- RECESSED TYPE -COLOR AS SELECTED BY THE ARCHITECT FROM MANUFACTURER'S STANDARD COLORS. M. ELECTRICAL 1. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL NOTES. 2. ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING SITE CONDITIONS, SERVICE REQUIREMENTS, AND EXACT LOCATIONS OF SERVICE FACILITIES. 3. ELECTRICAL CONTRACTOR SHALL CHECK WITH OTHER TRADES FOR LOCATION OF EQUIPMENT WHICH REQUIRES ANY HOOK-UP, DISCONNECT SWITCHES, RELAYS, ETC. PRIOR TO ANY START OF WORK. 4. LOCATIONS SHOWN ON ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ELECTRICAL DRAWINGS. 5. EXIT SIGNS WHERE NOTED SHALL BE WORDED "EXIT" IN LETTERS SIX INCHES (6") HIGH AND SHALL CONFORM WITH GOVERNING BUILDING CODES AND REGULATIONS. PROVIDE ILLUMINATED EXIT SIGNS WHERE NOTED AND/OR REQUIRED BY CODE. ILLUMINATED EXIT SIGNS SHALL BE LIGHTED AND WIRED ON SEPARATE CIRCUIT. 6. EXITS SHALL BE ILLUMINATED AT ANYTIME THE BUILDING IS OCCUPIED WITH A LIGHT HAVING AN INTENSITY OF NOT LESS THAN ONE FOOT -CANDLE AT FLOOR LEVEL PER C.B.C. 7. ADDITIONAL DIRECTIONAL EXIT SIGNAGE MAY BE REQUIRED BY THE AHJ AT THE TIME OF FINAL INSPECTION. N. FIRE ALARM (DESIGN BUILD) 1. THE CONTRACTOR SHALL PROVIDE A COMPLETE FIRE ALARM DETECTION SYSTEM WITHIN THE TENANT SPACE AS AN EXTENSION OF THE LANDLORD'S BUILDING WIDE ADDRESSABLE FIRE ALARM SYSTEM. 2. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE FIRE ALARM SYSTEM TO THE GOVERNING AGENCIES FOR APPROVAL PRIOR TO WORK IN THE FIELD. SHOP DRAWINGS SHALL BEAR STAMPED APPROVALS FOR THE AUTHORIZED AGENCIES AND BY ANY OTHER AGENCIES WHOSE APPROVALS ARE REQUIRED. LEGEND RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt GENERAL NOTES G201 RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt CALIFORNIA GREEN CHECKLIST G301A RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt CALIFORNIA GREEN CHECKLIST G301B RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt CALIFORNIA GREEN CHECKLIST G301C SIGNS 1.EXCEPT BUILDING DIRECTORIES, MENUS, SEAT AND ROW DESIGNATIONS IN ASSEMBLY AREAS, OCCUPANT NAMES, BUILDING ADDRESSES, AND COMPANY NAMES AND LOGOS, NEW OR ALTERED SIGNS SHALL BE PROVIDED IN ACCORDANCE WITH 11B-216 SIGNS AND SHALL COMPLY WITH 11B-703 SIGNS. THE ADDITION OF OR REPLACEMENT OF SIGNS SHALL NOT TRIGGER ANY ADDITIONAL PATH OF TRAVEL REQUIREMENTS. §11B-216.1 2.INTERIOR AND EXTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACESSHALL COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS. WHERE PICTOGRAMS ARE PROVIDED AS DESIGNATIONS OF PERMANENT INTERIOR ROOMS AND SPACES, THE PICTOGRAMS SHALL COMPLY WITH 11B-703.6 PICTOGRAMS AND SHALL HAVE TEXT DESCRIPTORS COMPLYING WITH 11B-703.2 AND 11B-703.5. §11B-216.2 (SEE EXCEPTION) 3.SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR AND EXTERIOR SPACES AND FACILITIES OF THE SITE SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS. §11B-216.3 4.SIGNS FOR MEANS OF EGRESS SHALL COMPLY WITH 11B-216.4 MEANS OF EGRESS: a. SIGNS REQUIRED BY SECTION 1013.4 AT DOORS TO EXIT PASSAGEWAYS, EXIT DISCHARGE, AND EXIT STAIRWAYS SHALL BE IDENTIFIED BY TACTILE SIGNS COMPLYING COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS. §11B-216.4.1 b. SIGNS REQUIRED BY SECTION 1009.11 TO PROVIDE INSTRUCTIONS IN AREAS OF REFUGE SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS. SIGNS REQUIRED BY SECTION 1009.9 AT DOORS TO AREAS OF REFUGE AND EXTERIOR AREAS FOR ASSISTED RESCUE SHALL COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS AND INCLUDE AN INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.4.2 c. SIGNS REQUIRED BY SECTION 1009.10 TO PROVIDE DIRECTIONS TO ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS. §11B-216.4.3 d. SIGNS REQUIRED BY SECTION 1010.1.9.7, ITEM 6.4 AT DOORS WITH DELAYED EGRESS LOCKS SHALL COMPLY WITH 11B-703.1 GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS. §11B-216.4.4 5.SIGNS WITHIN PARKING FACILITIES SHALL COMPLY WITH SECTION 11B-216.5.2. § 11B-216.5 6.IN EXISTING BUILDINGS AND FACILITIES WHERE NOT ALL ENTRANCES COMPLYWITH 11B-404 DOORS, DOORWAYS, AND GATES, COMPLIANT ENTRANCES SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. DIRECTIONAL SIGNS COMPLYING WITH 11B-703.5 VISUAL CHARACTERS THAT INDICATE THE LOCATION OF THE NEAREST ENTRANCE COMPLYING WITH 11B-404 SHALL BE PROVIDED AT ENTRANCES THAT DO NOT COMPLY WITH 11B-404 DOORS, DOORWAYS, AND GATES. DIRECTIONAL SIGNS COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE ISA COMPLYING WITH 11B-703.7.2.1 ISA, INDICATING THE ACCESSIBLE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE SHALL BE PROVIDED AT JUNCTIONS WHEN THE ACCESSIBLE ROUTE DIVERGES FROM THE REGULAR CIRCULATION PATH. §11B-216.6 7.WHERE EXISTING ELEVATORS DO NOT COMPLY WITH 11B-407 ELEVATORS, COMPLIANT ELEVATORS SHALL BE CLEARLY IDENTIFIED WITH THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC ELEVATORS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE ELEVATORS POSTED IN THE BUILDING LOBBY ON A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE ISA COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.7 8.ENTRANCES TO TOILET ROOMS AND BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING ROOM GEOMETRIC SYMBOLS. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST COMPLIANT TOILET ROOM OR BATHING ROOM WITHIN THE FACILITY SHALL BE PROVIDED. SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.8 9.WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, THE TOILET ROOMS OR BATHING ROOMS COMPLYING WITH SECTION 11B-603, SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH SECTION 11B-703.7.2.1 ISA. 11B-216.8 10.WHERE CLUSTERED SINGLE USER TOILET ROOMS OR BATHING FACILITIES ARE PERMITTED TO USE EXCEPTIONS TO 11B-213.2 TOILET AND BATHING ROOMS, TOILET ROOMS OR BATHING FACILITIES COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA UNLESS ALL TOILET ROOMS AND BATHING FACILITIES COMPLY WITH 11B-603 TOILET AND BATHING ROOMS. §11B-216.8 11.EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC TOILET ROOMS OR BATHING ROOMS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE ROOMS POSTED IN OR NEAR THE BUILDING LOBBY OR ENTRANCE ON A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.8 12.IDENTIFICATION AND DIRECTIONAL SIGNS FOR PUBLIC TTYS SHALL BE PROVIDED IN ACCORDANCE WITH 11B-216.9 TTYS. §11B-216.9 a. PUBLIC TTYS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF TTY COMPLYING WITH 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY. §11B-216.9.1 b. DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST PUBLIC TTY SHALL BE PROVIDED AT ALL BANKS OF PUBLIC PAY TELEPHONES NOT CONTAINING A PUBLIC TTY. IN ADDITION, WHERE SIGNS PROVIDE DIRECTION TO PUBLIC PAY TELEPHONES, THEY SHALL ALSO PROVIDE DIRECTION TO PUBLIC TTYS. IF A FACILITY HAS NO BANKS OF TELEPHONES, THE DIRECTIONAL SIGNS SHALL BE PROVIDED AT THE ENTRANCE OR IN A BUILDING DIRECTORY. DIRECTIONAL SIGNS SHALL COMPLY WITH 11B-703.5 AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF TTY COMPLYING WITH 11B-703.7.2.2. §11B-216.9.2 13.EACH ASSEMBLY AREA REQUIRED BY 11B-219 ASSISTIVE LISTENING SYSTEMS TO PROVIDE ASSISTIVE LISTENING SYSTEMS SHALL PROVIDE SIGNS INFORMING PATRONS OF THE AVAILABILITY OF THE ASSISTIVE LISTENING SYSTEM. THE SIGN SHALL INCLUDE WORDING THAT STATES “ASSISTIVE-LISTENING SYSTEM AVAILABLE”AND SHALL BE POSTED IN A PROMINENT PLACE AT OR NEAR THE ASSEMBLY AREA ENTRANCE. ASSISTIVE LISTENING SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS COMPLYING WITH 11B-703.7.2.4 ASSISTIVE LISTENING SYSTEMS. § 11B-216.10 (SEE EXCEPTION) 14.WHERE MORE THAN ONE CHECK-OUT AISLE IS PROVIDED, CHECK-OUT AISLES COMPLYING WITH 11B-904.3 CHECK-OUT AISLES SHALL BE IDENTIFIED BY A SIGN COMPLYING WITH 11B-904.3.4 IDENTIFICATION SIGN. WHERE CHECK-OUT AISLES ARE IDENTIFIED BY NUMBERS, LETTERS, OR FUNCTIONS, SIGNS IDENTIFYING CHECK-OUT AISLES COMPLYING WITH 11B-904.3 CHECK-OUT AISLES SHALL BE LOCATED IN THE SAME LOCATION AS THE CHECK-OUT AISLE IDENTIFICATION. §11B-216.11 (SEE EXCEPTION) 15.SIGNS IDENTIFYING THE TYPE OF ACCESS PROVIDED ON AMUSEMENT RIDES SHALL BE PROVIDED AT ENTRIES TO QUEUES AND WAITING LINES. IN ADDITION, WHERE ACCESSIBLE UNLOAD AREAS ALSO SERVE AS ACCESSIBLE LOAD AREAS, SIGNS INDICATING THE LOCATION OF THE ACCESSIBLE LOAD AND UNLOAD AREAS SHALL BE PROVIDED AT ENTRIES TO QUEUES AND WAITING LINES. SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.12 16.WHERE PROVIDED IN TRANSPORTATION FACILITIES, VARIABLE MESSAGE SIGNS CONVEYING TRANSPORTATION RELATED INFORMATION SHALL COMPLY WITH SECTION 11B-703.8. WHERE PROVIDED IN BUILDINGS THAT ARE DESIGNED AS EMERGENCY SHELTERS, VARIABLE MESSAGE SIGNS CONVEYING EMERGENCY RELATED INFORMATION SHALL COMPLY WITH SECTION 11B-703.8. §11B-216.13 17.SIGNS SHALL COMPLY WITH 11B-703 SIGNS. WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ONE SIGN WITH BOTH VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILE CHARACTERS, SHALL BE PROVIDED. §11B-703.1 a. SIGNS AS SPECIFIED IN SECTION 11B-703 SIGNS, OR IN OTHER SECTIONS OF THIS CODE, WHEN INCLUDED IN THE CONSTRUCTION OF NEW BUILDINGS OR FACILITIES, OR WHEN INCLUDED, ALTERED OR REPLACED DUE TO ADDITIONS, ALTERATIONS OR RENOVATIONS TO EXISTING BUILDINGS OR FACILITIES, AND WHEN A PERMIT IS REQUIRED, SHALL COMPLY WITH 11B-703.1.1.1 PLAN REVIEW AND 11B-703.1.1.2 INSPECTION. §11B-703.1.1 b. PLANS, SPECIFICATIONS OR OTHER INFORMATION INDICATING COMPLIANCE WITH THESE REGULATIONS SHALL BE SUBMITTED TO THE ENFORCING AGENCY FOR REVIEW AND APPROVAL. §11B-703.1.1.1 c. SIGNS AND IDENTIFICATION DEVICES SHALL BE FIELD INSPECTED AFTER INSTALLATION AND APPROVED BY THE ENFORCING AGENCY PRIOR TO THE ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER CHAPTER 1, DIVISION II, SECTION 111, OR FINAL APPROVAL WHERE NO CERTIFICATE OF OCCUPANCY IS ISSUED. THE INSPECTION SHALL INCLUDE, BUT NOT BE LIMITED TO, VERIFICATION THAT BRAILLE DOTS AND CELLS ARE PROPERLY SPACED AND THE SIZE, PROPORTION AND TYPE OF RAISED CHARACTERS ARE IN COMPLIANCE WITH THESE REGULATIONS. §11B-703.1.1.2 18.RAISED CHARACTERS SHALL COMPLY WITH 11B-703.2 RAISED CHARACTERS AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH 11B-703.3 BRAILLE. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH 11B-703.4 INSTALLATION HEIGHT AND LOCATION. §11B-703.2 a. RAISED CHARACTERS SHALL BE 1/32 INCH MINIMUM ABOVE THEIR BACKGROUND. §11B-703.2.1 b. CHARACTERS SHALL BE UPPERCASE. §11B-703.2.2 c. CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. §11B-703.2.3 d. CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER “O”IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER “I”. § 11B-703.2.4 e. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8 INCH MINIMUM AND 2 INCHES MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER “I”. §11B-703.2.5 f. STROKE THICKNESS OF THE UPPERCASE LETTER “I”SHALL BE 15 PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER. §11B-703.2.6 g. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT RAISED CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. WHERE CHARACTERS HAVE RECTANGULAR CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM. WHERE CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/16 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE BASE OF THE CROSS SECTIONS, AND 1/8 INCH MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE SEPARATED FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8 INCH MINIMUM. §11B-703.2.7 h. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHARACTERS WITHIN A MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE RAISED CHARACTER HEIGHT. § 11B-703.2.8 i. TEXT SHALL BE IN A HORIZONTAL FORMAT. §11B-703.2.9 22. SYMBOLS SHALL COMPLY WITH THE FOLLOWING: a. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS. THE SYMBOL SHALL BE MOUNTED AT 58 INCHES MINIMUM AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED FROM THE CENTERLINE OF THE SYMBOL. WHERE A DOOR IS PROVIDED, THE SYMBOL SHALL BE MOUNTED WITHIN 1 INCH OF THE VERTICAL CENTERLINE OF THE DOOR. § 11B-703.7.2.6 (SEE EXCEPTION) b. A TRIANGLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO MEN'S TOILET AND BATHING FACILITIES AND IT SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE, ¼ INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.1 c. A CIRCLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO WOMEN'S TOILET AND BATHING FACILITIES AND IT SHALL BE IDENTIFIED BY A CIRCLE, ¼ INCH THICK AND 12 INCHES IN DIAMETER. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.2 d. COMBINED CIRCLE AND TRIANGLE SYMBOL SHALL BE LOCATED AT ENTRANCES TO UNISEX TOILET AND BATHING FACILITIES AND IT SHALL BE SHALL BE IDENTIFIED BY A CIRCLE, ¼ INCH THICK AND 12 INCHES IN DIAMETER WITH A ¼ INCH THICK TRIANGLE WITH A VERTEX POINTING UPWARD SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12-INCH DIAMETER. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. §11B-703.7.2.6.3 WASHING MACHINE AND CLOTHES DRYERS 1.WASHING MACHINES AND CLOTHES DRYER'S OPERABLE PARTS MUST COMPLY WITH SECTION 11B-309 OPERABLE PARTS. §11B-611.3 2.TOP LOADING MACHINES SHALL HAVE THE DOOR TO THE LAUNDRY COMPARTMENT LOCATED 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR. FRONT LOADING MACHINES SHALL HAVE THE BOTTOM OF THE OPENING TO THE LAUNDRY COMPARTMENT LOCATED 15 INCHES MINIM AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR. §11B-611.4 F.COMMUNICATION ELEMENTS AND FEATURES FIRE ALARM SYSTEMS 1.WHERE FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS PROVIDE AUDIBLE ALARM COVERAGE, ALARMS SHALL COMPLY WITH 11B-215 FIRE ALARM SYSTEMS. §11B-215.1 (SEE EXCEPTION) 2.ALARMS IN PUBLIC USE AREAS AND COMMON USE AREAS SHALL COMPLY WITH 702 CHAPTER 9, SECTION 907.5.2.3.1. §11B-215.2 3.WHERE EMPLOYEE WORK AREAS HAVE AUDIBLE ALARM COVERAGE, THE WIRING SYSTEM SHALL BE DESIGNED SO THAT VISIBLE ALARMS COMPLYING WITH 702 CHAPTER 9, SECTION 907.5.2.3.2 CAN BE INTEGRATED INTO THE ALARM SYSTEM. §11B-215.3 4.FIRE ALARM SYSTEMS SHALL HAVE PERMANENTLY INSTALLED AUDIBLE AND VISIBLE ALARMS COMPLYING WITH NFPA 72 (1999 OR 2002 EDITION) (INCORPORATED BY REFERENCE, SEE “REFERENCED STANDARDS”IN CHAPTER 1), EXCEPT THAT THE MAXIMUM ALLOWABLE SOUND LEVEL OF AUDIBLE NOTIFICATION APPLIANCES COMPLYING WITH SECTION 4-3.2.1 OF NFPA 72 (1999 EDITION) SHALL HAVE A SOUND LEVEL NO MORE THAN 110 DB AT THE MINIMUM HEARING DISTANCE FROM THE AUDIBLE APPLIANCE. IN ADDITION, ALARMS IN GUEST ROOMS REQUIRED TO PROVIDE COMMUNICATION FEATURES SHALL COMPLY WITH SECTIONS 4-3 AND 4-4 OF NFPA 72 (1999 EDITION) OR SECTIONS 7.4 AND 7.5 OF NFPA 72 (2002 EDITION), AND CHAPTER 9, SECTIONS 907.5.2.1 AND 907.5.2.3. §11B-702.1 ASSISTIVE LISTENING SYSTEMS 5.ASSISTIVE LISTENING SYSTEMS SHALL BE PROVIDED IN ASSEMBLY AREAS, INCLUDING CONFERENCE AND MEETING ROOMS, USED FOR THE PURPOSE OF ENTERTAINMENT, EDUCATIONAL OR CIVIC GATHERINGS, OR SIMILAR PURPOSES. §202, § 11B-219.2 NOTE: ASSEMBLY AREAS INCLUDE, BUT ARE NOT LIMITED TO, CLASSROOMS, LECTURE HALLS, COURTROOMS, PUBLIC MEETING ROOMS, PUBLIC HEARING ROOMS, LEGISLATIVE CHAMBERS, MOTION PICTURE HOUSES, AUDITORIA, THEATERS, PLAYHOUSES, DINNER THEATERS, CONCERT HALLS, CENTERS FOR THE PERFORMING ARTS, AMPHITHEATERS, ARENAS, STADIUMS, GRANDSTANDS, OR CONVENTION CENTERS. §202, § 11B-219.2 6.ASSISTIVE LISTENING SYSTEM SHALL PROVIDE AN AMPLIFICATION SYSTEM UTILIZING TRANSMITTERS, RECEIVERS, AND COUPLING DEVICES TO BYPASS THE ACOUSTICAL SPACE BETWEEN A SOUND SOURCE AND A LISTENER BY MEANS OF INDUCTION LOOP, RADIO FREQUENCY, INFRARED, OR DIRECT-WIRED EQUIPMENT. §202 7.WHERE A BUILDING CONTAINS MORE THAN ONE ASSEMBLY AREA UNDER ONE MANAGEMENT, THE TOTAL NUMBER OF REQUIRED RECEIVERS MAY BE CALCULATED USING THE TOTAL NUMBER OF SEATS IN THE ASSEMBLY AREAS PROVIDED THAT ALL RECEIVERS ARE USABLE WITH ALL SYSTEMS. §11B-219.3 (SEE EXCEPTION) 8.TWENTY-FIVE PERCENT MINIMUM OF RECEIVERS PROVIDED FOR ASSISTIVE LISTENING SYSTEMS, BUT NO FEWER THAN TWO, SHALL BE HEARING-AID COMPATIBLE EXCEPT WHEN ALL SEATS IN AN ASSEMBLY AREA ARE SERVED BY MEANS OF AN INDUCTION LOOP. §11B-219.3 9.WHEN ASSISTIVE-LISTENING SYSTEMS ARE LIMITED TO SPECIFIC AREAS OR SEATS, SUCH AREAS OR SEATS SHALL BE WITHIN A 50-FOOT VIEWING DISTANCE OF THE STAGE OR PLAYING AREA AND SHALL HAVE A COMPLETE VIEW OF THE STAGE OR PLAYING AREA. §11B-219.4 10.PERMANENTLY INSTALLED ASSISTIVE-LISTENING SYSTEMS ARE REQUIRED IN AREAS IF (1) THEY HAVE FIXED SEATING AND (2A) THEY ACCOMMODATE AT LEAST 50 PERSONS OR (2B) THEY HAVE AUDIO-AMPLIFICATION SYSTEMS, EXCEPT THOSE USED EXCLUSIVELY FOR PAGING AND/OR BACKGROUND MUSIC. §11B-219.2, §11B-219.5 11.PORTABLE ASSISTIVE-LISTENING SYSTEMS MAY SERVE MORE THAN ONE CONFERENCE OR MEETING ROOMS IF AN ADEQUATE NUMBER OF ELECTRICAL OUTLETS OR OTHER SUPPLEMENTARY WIRING IS PROVIDED AND PERMANENTLY INSTALLED SYSTEMS ARE NOT REQUIRED. §11B-219.5 12.RECEIVERS REQUIRED FOR USE WITH AN ASSISTIVE LISTENING SYSTEM SHALL INCLUDE A 1/8 INCH STANDARD MONO JACK. §11B-706.2 13.RECEIVERS REQUIRED TO BE HEARING AID COMPATIBLE SHALL INTERFACE WITH TELECOILS IN HEARING AIDS THROUGH THE PROVISION OF NECK LOOPS. §11B-706.3 14.ASSISTIVE LISTENING SYSTEMS SHALL BE CAPABLE OF PROVIDING A SOUND PRESSURE LEVEL FROM 110 -118 DB WITH A DYNAMIC RANGE ON THE VOLUME CONTROL OF 50 DB. §11B-706.4 15.SIGNAL-TO-NOISE RATIO FOR INTERNALLY GENERATED NOISE IN ASSISTIVE LISTENING SYSTEMS SHALL BE 18 DB MINIMUM. §11B-706.5 16.PEAK CLIPPING SHALL NOT EXCEED 18 DB OF CLIPPING RELATIVE TO THE PEAKS OF SPEECH. §11B-706.6 TWO-WAY COMMUNICATION SYSTEMS 17.TWO-WAY COMMUNICATION SYSTEMS THAT ARE PROVIDED TO GAIN ADMITTANCE TO A BUILDING OR FACILITY OR TO RESTRICTED AREAS WITHIN A BUILDING OR FACILITY SHALL PROVIDE BOTH AUDIBLE AND VISUAL SIGNALS. HANDSET CORDS, IF PROVIDED, SHALL BE 29 INCHES LONG MINIMUM. §11B-230.1, §11B-708 18.COMMON USE OR PUBLIC USE SYSTEM INTERFACE OF COMMUNICATIONS SYSTEMS BETWEEN A RESIDENTIAL DWELLING UNIT AND A SITE, BUILDING, OR FLOOR ENTRANCE SHALL INCLUDE THE CAPABILITY OF SUPPORTING VOICE AND TTY COMMUNICATION WITH THE RESIDENTIAL DWELLING UNIT INTERFACE. §11B-708.4.1 19.RESIDENTIAL DWELLING UNIT SYSTEM INTERFACE OF COMMUNICATIONS SYSTEMS BETWEEN A RESIDENTIAL DWELLING UNIT AND A SITE, BUILDING, OR FLOOR ENTRANCE SHALL INCLUDE A TELEPHONE JACK CAPABLE OF SUPPORTING VOICE AND TTY COMMUNICATION WITH THE COMMON USE OR PUBLIC USE SYSTEM INTERFACE. § 11B-708.4.2 TELEPHONES 20.WHERE COIN-OPERATED PUBLIC PAY TELEPHONES, COIN LESS PUBLIC PAY TELEPHONES, PUBLIC CLOSED-CIRCUIT TELEPHONES, PUBLIC COURTESY PHONES, OR OTHER TYPES OF PUBLIC TELEPHONES ARE PROVIDED, PUBLIC TELEPHONES SHALL BE PROVIDED IN ACCORDANCE WITH 11B-217 TELEPHONES FOR EACH TYPE OF PUBLIC TELEPHONE PROVIDED. FOR PURPOSES OF THIS SECTION, A BANK OF TELEPHONES SHALL BE CONSIDERED TO BE TWO OR MORE ADJACENT TELEPHONES. §11B-217.1 21.EXCEPT DRIVE-UP ONLY PUBLIC TELEPHONES, WHERE PUBLIC TELEPHONES ARE PROVIDED, WHEELCHAIR ACCESSIBLE TELEPHONES COMPLYING WITH 11B-704.2 SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 11B-217.2. §11B-217.2 22.ALL PUBLIC TELEPHONES SHALL HAVE VOLUME CONTROLS COMPLYING WITH 11B-704.3. §11B-217.3 23.TTYS COMPLYING WITH 11B-704.4 SHALL BE PROVIDED IN ACCORDANCE WITH 11B-217.4. 24.WHERE A BANK OF TELEPHONES IN THE INTERIOR OF A BUILDING CONSISTS OF THREE OR MORE PUBLIC PAY TELEPHONES, AT LEAST ONE PUBLIC PAY TELEPHONE AT THE BANK SHALL BE PROVIDED WITH A SHELF AND AN ELECTRICAL OUTLET IN ACCORDANCE WITH 11B-704.5. §11B-217.5 (SEE EXCEPTION) D.GENERAL SITE AND BUILDING ELEMENTS 1.WHERE PARKING SPACES ARE PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN NUMBER AND KIND REQUIRED PER SECTION 11B-208 PARKING SPACES. §11B-208.1 2.WHERE PASSENGER LOADING ZONES, DROP-OFF ZONES, AND/OR BUS STOPS ARE PROVIDED, ACCESSIBLE PASSENGER LOADING ZONES, DROP-OFF ZONES, AND/OR BUS STOPS ARE REQUIRED. 3.WHERE ELECTRIC VEHICLE CHARGING STATIONS (EVCS) ARE PROVIDED, THEY SHALL COMPLY WITH SECTION 11B-812 AS REQUIRED BY SECTION 11B-228.3. 4.EVCS COMPLYING WITH SECTION 11B-812 THAT SERVE A PARTICULAR BUILDING OR FACILITY SHALL BE LOCATED ON AN ACCESSIBLE ROUTE TO AN ENTRANCE COMPLYING WITH SECTION 11B-206.4. WHERE EVCS DO NOT SERVE A PARTICULAR BUILDING OR FACILITY, EVCS COMPLYING WITH SECTION 11B-812 SHALL BE LOCATED ON AN ACCESSIBLE ROUTE TO AN ACCESSIBLE PEDESTRIAN ENTRANCE OF THE EV CHARGING FACILITY. E.PLUMBING FIXTURES AND FACILITIES DRINKING FOUNTAINS 1.DRINKING FOUNTAINS SHALL COMPLY WITH SECTIONS 11B-307 PROTRUDING OBJECTS AND 11B-602 GENERAL REQUIREMENTS. §11B-602.1 2.UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 CLEAR FLOOR OR GROUND SPACE POSITIONED FOR A FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 KNEE AND TOE CLEARANCE SHALL BE PROVIDED. §11B-602.2 3.SPOUT OUTLETS SHALL BE 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-602.4 4.THE SPOUT SHALL BE LOCATED 15 INCHES MINIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES MAXIMUM FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. §11B-602.5 5.THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES HIGH MINIMUM AND SHALL BE LOCATED 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT. WHERE SPOUTS ARE LOCATED LESS THAN 3 INCHES FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 30 DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED BETWEEN 3 INCHES AND 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAXIMUM. §11B-602.6 6.SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-602.7 7.WALL AND POST-MOUNTED CANTILEVERED DRINKING FOUNTAINS SHALL BE 18 INCHES MINIMUM AND 19 INCHES MAXIMUM IN DEPTH. §11B-602.8 8.ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN SUCH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32 INCHES WIDE MINIMUM AND 18 INCHES DEEP MINIMUM, AND SHALL COMPLY WITH SECTION 11B-305.7 MANEUVERING CLEARANCE. WHEN USED, WING WALLS OR BARRIERS SHALL PROTECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES VERTICALLY FROM THE FLOOR OR GROUND SURFACE. §11B-602.9 TOILET AND BATHING ROOM CLEARANCES 9.DOORS TO UNISEX TOILET ROOMS AND UNISEX BATHING ROOMS SHALL HAVE PRIVACY LATCHES. §11B-213.2.1 10.MIRRORS LOCATED ABOVE THE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITHIN THE BOTTOM EDGE OF THE REFLECTING SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE THE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. § 11B-603.3 11.COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308. SHELVES SHALL BE LOCATED 40 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR. MEDICINE CABINETS SHALL BE LOCATED WITH A USABLE SHELF NO HIGHER THAN 44 INCHES MAXIMUM ABOVE THE FINISH FLOOR. §11B-603.4 12.WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR. BABY CHANGING STATIONS ARE NOT REQUIRED TO COMPLY WITH SECTION 11B-603.5 (SEE EXCEPTION) §11B-603.5 WATER CLOSETS AND TOILET COMPARTMENTS 13.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 11B-309.4 OPERATION EXCEPT THEY SHALL BE LOCATED 44 INCHES MAXIMUM ABOVE THE FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET EXCEPT IN AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH SECTION 11B-604.8.2 AMBULATORY ACCESSIBLE COMPARTMENTS. §11B-604.6 14.TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 11B-309.4 OPERATION AND SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW THE GRAB BAR, 19 INCHES MINIMUM ABOVE THE FINISH FLOOR AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW. §11B-604.7 15.SANITARY NAPKIN DISPOSAL UNITS, IF PROVIDED, SHALL COMPLY WITH SECTION 11B-309.4 AND SHALL BE WALL MOUNTED AND LOCATED ON THE SIDEWALL BETWEEN THE REAR WALL OF THE TOILET AND THE TOILET PAPER DISPENSER, ADJACENT TO THE TOILET PAPER DISPENSER. THE DISPOSAL UNIT SHALL BE LOCATED BELOW THE GRAB BAR WITH THE OPENING OF THE DISPOSAL UNIT 19 INCHES MINIMUM (483 MM) ABOVE THE FINISH FLOOR. §11B-604.7.2 16.URINALS SHALL BE THE STALL-TYPE OR THE WALL-HUNG TYPE WITH THE RIM 17 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. URINALS SHALL BE 13½ INCHES DEEP MINIMUM MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE. §11B-605.2 17.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECTION 11B-309 OPERABLE PARTS EXCEPT THAT THE FLUSH CONTROL SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 44 INCHES ABOVE THE FINISH FLOOR. §11B-605.4 18.FOR LAVATORIES AND SINKS, A CLEAR FLOOR SPACE COMPLYING WITH SECTION 11B-305 CLEAR FLOOR OR GROUND SURFACES, POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 KNEE AND TOE CLEARANCE SHALL BE PROVIDED. §11B-606.2 19.LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-606.3 SIGNS RELATED TO TOILETS AND BATHING FACILITIES 20.ENTRANCES LEADING TO TOILET ROOMS AND BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL COMPLYING WITH 11B-703.7.2.6 TOILET AND BATHING ROOM GEOMETRIC SYMBOLS. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST COMPLIANT TOILET ROOM OR BATHING ROOM WITHIN THE FACILITY SHALL BE PROVIDED. SIGNS SHALL COMPLY WITH 11B-703.5 VISUAL CHARACTERS AND SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. WHERE EXISTING TOILET ROOMS OR BATHING ROOMS DO NOT COMPLY WITH 11B-603 TOILET AND BATHING ROOMS, THE TOILET ROOMS OR BATHING ROOMS COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. WHERE CLUSTERED SINGLE USER TOILET ROOMS OR BATHING FACILITIES ARE PERMITTED TO USE EXCEPTIONS TO 11B-213.2 TOILET AND BATHING ROOMS, TOILET ROOMS OR BATHING FACILITIES COMPLYING WITH 11B-603 TOILET AND BATHING ROOMS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA UNLESS ALL TOILET ROOMS AND BATHING FACILITIES COMPLY WITH 11B-603 TOILET AND BATHING ROOMS. EXISTING BUILDINGS THAT HAVE BEEN REMODELED TO PROVIDE SPECIFIC TOILET ROOMS OR BATHING ROOMS FOR PUBLIC USE THAT COMPLY WITH THESE BUILDING STANDARDS SHALL HAVE THE LOCATION OF AND THE DIRECTIONS TO THESE ROOMS POSTED IN OR NEAR THE BUILDING LOBBY OR ENTRANCE ON A SIGN COMPLYING WITH 11B-703.5 VISUAL CHARACTERS, INCLUDING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY COMPLYING WITH 11B-703.7.2.1 ISA. §11B-216.8 21.PICTOGRAMS SHALL COMPLY WITH THE FOLLOWING: a. PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. § 11B-703.6.1 b. PICTOGRAMS AND THEIR FIELD SHALL HAVE A NON-GLARE FINISH. PICTOGRAMS SHALL CONTRAST WITH THEIR FIELD WITH EITHER A LIGHT PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. § 11B-703.6.2 c. PICTOGRAMS SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. TEXT DESCRIPTORS SHALL COMPLY WITH 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.4 INSTALLATION HEIGHT AND LOCATION. §11B-703.6.3 d. THE INSTALLATION HEIGHT AND LOCATION OF PICTOGRAM SIGNS SHALL BE PER §11B-703.4.1. HANDRAILS 1.HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS. § 11B-505.2 2.HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG STAIRS AND RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS. § 11B-505.3 3.TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES MINIMUM AND 38 INCHES MAXIMUM VERTICALLY ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. HANDRAILS SHALL BE AT A CONSISTENT HEIGHT ABOVE WALKING SURFACES, STAIR NOSINGS, AND RAMP SURFACES. §11B-505.4 4.CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACES AND ADJACENT SURFACES SHALL BE 1½ INCHES MINIMUM. HANDRAILS MAY BE LOCATED IN A RECESS IF THE RECESS IS 3 INCHES MAXIMUM DEEP AND 18 INCHES MINIMUM CLEAR ABOVE THE TOP OF THE HANDRAIL. §11B-505.5 5.HANDRAIL GRIPPING SURFACES SHALL BE CONTINUOUS ALONG THEIR LENGTH AND SHALL NOT BE OBSTRUCTED ALONG THEIR TOPS OR SIDES. THE BOTTOMS OF HANDRAIL GRIPPING SURFACES SHALL NOT BE OBSTRUCTED FOR MORE THAN 20 PERCENT OF THEIR LENGTH. WHERE PROVIDED, HORIZONTAL PROJECTIONS SHALL OCCUR 1½ INCHES MINIMUM BELOW THE BOTTOM OF THE HANDRAIL-GRIPPING SURFACE. §11B-505.6 6.HANDRAIL GRIPPING SURFACES WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1¼ INCHES MINIMUM AND 2 INCHES MAXIMUM. § 11B-505.7.1 7.HANDRAIL GRIPPING SURFACES WITH A NON-CIRCULAR CROSS SECTION SHALL HAVE A PERIMETER DIMENSION OF 4 INCHES MINIMUM AND 6¼ INCHES MAXIMUM, AND A CROSS-SECTION DIMENSION OF 2¼ INCHES MAXIMUM. § 11B-505.7.2 8.HANDRAIL GRIPPING SURFACES SHALL EXTEND BEYOND AND IN THE SAME DIRECTION OF STAIR FLIGHTS AND RAMP RUNS IN ACCORDANCE WITH SECTION 11B-505.10 HANDRAIL EXTENSIONS. §11B-505.10 9.RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES MINIMUM BEYOND THE TOP AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN. §11B-505.10.1 10.AT THE TOP OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES MINIMUM BEGINNING DIRECTLY ABOVE THE FIRST RISER NOSING. EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. §11B-505.10.2 11.AT THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER NOSING. THE HORIZONTAL EXTENSION OF A HANDRAIL SHALL BE 12 INCHES LONG MINIMUM AND A HEIGHT EQUAL TO THAT OF THE SLOPING PORTION OF THE HANDRAIL AS MEASURED ABOVE THE STAIR NOSINGS. EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. §11B-505.10. STAIRWAYS 1.A STAIR IS DEFINED AS A CHANGE IN ELEVATION, CONSISTING OF ONE OR MORE RISERS. §11B-202 2.ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHTS AND UNIFORM TREAD DEPTHS. RISERS SHALL BE 4 INCHES HIGH MINIMUM AND 7 INCHES HIGH MAXIMUM. TREADS SHALL BE 11 INCHES DEEP MINIMUM. CURVED STAIRWAYS WITH WINDER TREADS ARE PERMITTED AT STAIRS WHICH ARE NOT PART OF A REQUIRED MEANS OF EGRESS. (SEE EXCEPTION) §11B-504.2 3.OPEN RISERS ARE NOT PERMITTED. §11B-504.3 (SEE EXCEPTIONS) 4.INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. THE STRIPE SHALL BE A MINIMUM OF 2 INCHES WIDE TO A MAXIMUM OF 4 INCHES WIDE PLACED PARALLEL TO, AND NOT MORE THAN 1 INCH FROM, THE NOSE OF THE STEP OR UPPER APPROACH. THE STRIPE SHALL EXTEND THE FULL WIDTH OF THE STEP OR UPPER APPROACH AND SHALL BE OF MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. A PAINTED STRIPE SHALL BE ACCEPTABLE. GROOVES SHALL NOT BE USED TO SATISFY THIS REQUIREMENT. §11B-504.4.1 5.THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE ½ INCH MAXIMUM. NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED. RISERS SHALL BE PERMITTED TO SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAXIMUM FROM VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL EXTEND 1¼ INCHES MAXIMUM OVER THE TREAD BELOW. §11B-504.5 (SEE EXCEPTION FOR EXISTING BUILDINGS) 6.STAIRS SHALL HAVE HANDRAILS COMPLYING WITH SECTION 11B-505 HANDRAILS. §11B-504.6 7.STAIR TREADS AND LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. §11B-504.7 8.FLOOR IDENTIFICATION SIGNS REQUIRED BY CHAPTER 10, SECTION 1022.9 COMPLYING WITH SECTIONS 11B-703.1 SIGNS GENERAL, 11B-703.2 RAISED CHARACTERS, 11B-703.3 BRAILLE AND 11B-703.5 VISUAL CHARACTERS SHALL BE LOCATED AT THE LANDING OF EACH FLOOR LEVEL, PLACED ADJACENT TO THE DOOR ON THE LATCH SIDE, IN ALL ENCLOSED STAIRWAYS IN BUILDINGS TWO OR MORE STORIES IN HEIGHT TO IDENTIFY THE FLOOR LEVEL. AT THE EXIT DISCHARGE LEVEL, THE SIGN SHALL INCLUDE A RAISED FIVE POINTED STAR LOCATED TO THE LEFT OF THE IDENTIFYING FLOOR LEVEL. THE OUTSIDE DIAMETER OF THE STAR SHALL BE THE SAME AS THE HEIGHT OF THE RAISED CHARACTERS. §11B-504.8 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS 9.PERPENDICULAR RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%). §11B-406.2.1 10.FOR PERPENDICULAR RAMPS, WHERE PROVIDED, CURB RAMP FLARES SHALL NOT BE STEEPER THAN 1:10. §11B-406.2, FIGURE 11B-406.2.2 11.THE RUNNING SLOPE OF THE CURB RAMP SEGMENTS SHALL BE IN-LINE WITH THE DIRECTION OF SIDEWALK TRAVEL. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%). §11B-406.3.1, FIGURE 11B-406.3.2 12.A TURNING SPACE 48 INCHES MINIMUM BY 48 INCHES MINIMUM SHALL BE PROVIDED AT THE BOTTOM OF THE CURB RAMP. THE SLOPE OF THE TURNING SPACE IN ALL DIRECTIONS SHALL BE 1:48 MAXIMUM (2.083%). §11B-406.3.2 13.BLENDED TRANSITION RAMPS HALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:20 (5%). §11B-406.4.1 14.CURB RAMPS AND THE FLARED SIDES OF CURB RAMPS SHALL BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB RAMPS AT MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARED SIDES. §11B-406.5.1 15.THE CLEAR WIDTH OF CURB RAMP RUNS (EXCLUDING ANY FLARED SIDES), BLENDED TRANSITIONS, AND TURNING SPACES SHALL BE 48 INCHES MINIMUM. § 11B-406.5.2 16.LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB RAMPS AND BLENDED TRANSITIONS (PARALLEL CURB RAMPS SHALL NOT BE REQUIRED TO COMPLY). THE LANDING CLEAR LENGTH SHALL BE 48 INCHES MINIMUM. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE CURB RAMP, EXCLUDING ANY FLARED SIDES, OR THE BLENDED TRANSITION LEADING TO THE LANDING. THE SLOPE OF THE LANDING IN ALL DIRECTIONS SHALL BE 1:48 (2.083%) MAXIMUM. §11B-406.5.3 17.GRADE BREAKS AT THE TOP AND BOTTOM OF CURB RAMP RUNS SHALL BE PERPENDICULAR TO THE DIRECTION OF THE RAMP RUN. GRADE BREAKS SHALL NOT BE PERMITTED ON THE SURFACE OF RAMP RUNS AND TURNING SPACES. SURFACE SLOPES THAT MEET AT GRADE BREAKS SHALL BE FLUSH. §11B-406.5.6 18.THE CROSS SLOPE OF CURB RAMPS AND BLENDED TRANSITIONS SHALL BE 1:48 (2.083%) MAXIMUM. §11B-406.5.7 19.COUNTER SLOPES OF ADJOINING GUTTERS AND ROAD SURFACES IMMEDIATELY ADJACENT TO AND WITHIN 24 INCHES OF THE CURB RAMP SHALL NOT BE STEEPER THAN 1:20 (5%). THE ADJACENT SURFACES AT TRANSITIONS AT CURB RAMPS TO WALKS, GUTTERS, AND STREETS SHALL BE AT THE SAME LEVEL. § 11B-406.5.8 20.THE BOTTOM OF DIAGONAL CURB RAMPS SHALL HAVE A CLEAR SPACE 48 INCHES MINIMUM OUTSIDE ACTIVE TRAFFIC LANES OF THE ROADWAY. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS SHALL PROVIDE THE 48 INCHES MINIMUM CLEAR SPACE WITHIN THE MARKINGS. §11B-406.5.9 21.CURB RAMPS AND BLENDED TRANSITIONS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH 11B-705 DETECTABLE WARNINGS. §11B-406.5.12 22.RAISED ISLANDS IN CROSSINGS SHALL BE CUT THROUGH LEVEL WITH THE STREET OR HAVE CURB RAMPS AT BOTH SIDES. THE CLEAR WIDTH OF THE ACCESSIBLE ROUTE AT ISLANDS SHALL BE 60 INCHES WIDE MINIMUM. WHERE CURB RAMPS ARE PROVIDED, THEY SHALL COMPLY WITH 11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS. LANDINGS COMPLYING WITH 11B-406.5.3 LANDINGS AND THE ACCESSIBLE ROUTE SHALL BE PERMITTED TO OVERLAP. ISLANDS SHALL HAVE DETECTABLE WARNINGS COMPLYING WITH 11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE. §11B-406.6, FIGURE 11B-406.6 24.HIGH SIDE REACH SHALL BE 46 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND WHERE THE HIGH SIDE REACH IS OVER AN OBSTRUCTION MORE THAN 10 INCHES BUT NOT MORE THAN 24 INCHES IN DEPTH. §11B-308.3.2, FIGURE 11B-308.3.2 25.OBSTRUCTIONS FOR HIGH SIDE REACH SHALL NOT EXCEED 34 INCHES IN HEIGHT AND 24 INCHES IN DEPTH. §11B-308.3.2, FIGURE 11B-308.3.2 26.OBSTRUCTIONS FOR HIGH SIDE REACH SHALL NOT EXCEED 34 INCHES IN HEIGHT AND 24 INCHES IN DEPTH. §11B-308.3.2, FIGURE 11B-308.3.2 27.OBSTRUCTED HIGH SIDE REACH FOR THE TOP OF WASHING MACHINES AND CLOTHES DRYERS SHALL BE PERMITTED TO BE 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR. §11B-308.3.2 28.OBSTRUCTED HIGH SIDE REACH FOR THE OPERABLE PARTS OF FUEL DISPENSERS SHALL BE PERMITTED TO BE 54 INCHES MAXIMUM MEASURED FROM THE SURFACE OF THE VEHICULAR WAY WHERE FUEL DISPENSERS ARE INSTALLED ON EXISTING CURBS. §11B-308.3.2 OPERABLE PARTS 1.OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM. §11B-309.4 C.ACCESSIBLE ROUTES DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE 1.DETECTABLE WARNING SURFACES SHALL BE YELLOW AND APPROXIMATE FS 33538 OF FEDERAL STANDARD 595C. §11B-705.1.1.3.1 2.DETECTABLE WARNING SURFACES SHALL PROVIDE A 70 PERCENT MINIMUM VISUAL CONTRAST WITH ADJACENT WALKING SURFACES. CONTRAST IN PERCENT SHALL BE DETERMINED BY: CONTRAST PERCENT = [(B1-B2)/B1] X 100 WHERE B1 = LIGHT REFLECTANCE VALUE (LRV) OF THE LIGHTER AREA AND B2 = LIGHT REFLECTANCE VALUE (LRV) OF THE DARKER AREA §11B-705.1.1.3.2 (SEE EXCEPTION) DOORS DOORWAYS, AND GATES 3.DOORS, DOORWAYS, AND GATES PROVIDING USER PASSAGE SHALL BE PROVIDED IN ACCORDANCE WITH 11B-206.5 DOORS, DOORWAYS, AND GATES. §11B-206.5 4.DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH 11B-404 DOORS, DOORWAYS, AND GATES. §11B-404.1 5.DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES. §11B-404.2.3 6.SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.1. §11B-404.2.4.1 7.DOORWAYS LESS THAN 36 INCHES WIDE WITHOUT DOORS OR GATES, SLIDING DOORS, OR FOLDING DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.2. §11B-404.2.4.2 8.MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES OF THE LATCH SIDE AN INTERIOR DOORWAY, OR WITHIN 24 INCHES OF THE LATCH SIDE OF AN EXTERIOR DOORWAY, PROJECTS MORE THAN 8 INCHES BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE. §11B-404.2.4.3 9.THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE ½ INCH HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES AND 11B-303 CHANGES IN LEVEL. §11B-404.2.5 10.HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH 11B-309.4 OPERATION. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. § 11B-404.2.7 11.THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: §11B-404.2.9 a. INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAXIMUM. b. SLIDING OR FOLDING DOORS: 5 POUNDS MAXIMUM. c. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. d. EXTERIOR HINGED DOORS: 5 POUNDS MAXIMUM. 12.SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. §11B-404.2.10 RAMPS 13.RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN 1:12 (8.33%). § 11B-405.2 14.CROSS SLOPE OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48 (2.083%). § 11B-405.3 15.FLOOR OR GROUND SURFACES OF RAMP RUNS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES. CHANGES IN LEVEL OTHER THAN THE RUNNING SLOPE AND CROSS SLOPE ARE NOT PERMITTED ON RAMP RUNS. §11B-405.4 16.THE CLEAR WIDTH OF A RAMP RUN SHALL BE 48 INCHES MINIMUM. §11B-405.5 17.THE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES MAXIMUM. §11B-405.6 18.RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE BOTTOM OF EACH RAMP RUN. §11B-405.7 19.LANDINGS SHALL COMPLY WITH 11B-302 FLOOR OR GROUND SURFACES. CHANGES IN LEVEL ARE NOT PERMITTED. §11B-405.7.1 20.THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE WIDEST RAMP RUN LEADING TO THE LANDING. §11B-405.7.2 21.TOP LANDINGS SHALL BE 60 INCHES WIDE MINIMUM. §11B-405.7.2.1 22.THE LANDING CLEAR LENGTH SHALL BE 60 INCHES LONG MINIMUM. §11B-405.7.3 23.BOTTOM LANDINGS SHALL EXTEND 72 INCHES MINIMUM IN THE DIRECTION OF RAMP RUN. §11B-405.7.3.1 24.RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING 60 INCHES MINIMUM BY 72 INCHES MINIMUM IN THE DIRECTION OF DOWNWARD TRAVEL FROM THE UPPER RAMP RUN. §11B-405.7.4 25.WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY 11B-404.2.4 AND 11B-404.3.2 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. DOORS, WHEN FULLY OPEN, SHALL NOT REDUCE THE REQUIRED RAMP LANDING WIDTH BY MORE THAN 3 INCHES. DOORS, IN ANY POSITION, SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP LANDING TO LESS THAN 42 INCHES. §11B-405.7.5 26.RAMP RUNS SHALL HAVE COMPLIANT HANDRAILS PER 11B-505 HANDRAILS. § 11B-405.8 27.EDGE PROTECTION COMPLYING WITH 11B-405.9.2 CURB OR BARRIER SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP LANDINGS. § 11B-405.9 (SEE EXCEPTIONS) 28.A CURB, 2 INCHES HIGH MINIMUM, OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4 INCH DIAMETER SPHERE, WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR OR GROUND SURFACE. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE A CONTINUOUS AND UNINTERRUPTED BARRIER ALONG THE LENGTH OF THE RAMP. §11B-405.9.2 29.LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE ACCUMULATION OF WATER. §11B-405.10 HANDRAILS A.APPLICATION AND ADMINISTRATION 1.PUBLIC ACCOMMODATIONS SHALL MAINTAIN IN OPERABLE WORKING CONDITION THOSE FEATURES OF FACILITIES AND EQUIPMENT THAT ARE REQUIRED TO BE ACCESSIBLE TO AND USEABLE BY PERSONS WITH DISABILITIES. ISOLATED OR TEMPORARY INTERRUPTIONS IN SERVICE OR ACCESSIBILITY DUE TO MAINTENANCE OR REPAIRS SHALL BE PERMITTED. §11B-108 2.WHEN ALTERATIONS OR ADDITIONS ARE MADE TO EXISTING BUILDINGS OR FACILITIES, AN ACCESSIBLE PATH OF TRAVEL TO THE SPECIFIC AREA OF ALTERATION OR ADDITION SHALL BE PROVIDED UNLESS OTHERWISE EXEMPT. §11B-202.4 3.PRIMARY ACCESSIBLE PATH OF TRAVEL SHALL INCLUDE A PRIMARY ENTRANCE TO THE BUILDING OR FACILITY; TOILET AND BATHING FACILITIES SERVING THE AREA; DRINKING FOUNTAINS SERVING THE AREA; PUBLIC TELEPHONES SERVING THE AREA, AND SIGNS. §11B-202. 4.WHEN THE ADJUSTED CONSTRUCTION COST IS LESS THAN OR EQUAL TO THE CURRENT VALUATION THRESHOLD $147,863.00, THE COST OF COMPLIANCE WITH THE PRIMARY ACCESSIBLE PATH OF TRAVEL REQUIREMENTS IS LIMITED TO 20 PERCENT OF THE ADJUSTED CONSTRUCTION COST OF ALTERATIONS, STRUCTURAL REPAIRS OR ADDITIONS PRESENTLY PLANNED AND THOSE DURING THE PRECEDING THREE-YEAR PERIOD. §11B-202.4 5.ADJUSTED CONSTRUCTION COST OF ALTERATIONS, STRUCTURAL REPAIRS OR ADDITIONS DOES NOT INCLUDE THE COST OF ALTERATIONS TO PATH OF TRAVEL ELEMENTS. §11B-202.4 6.IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS IN THE FOLLOWING ORDER: (1) AN ACCESSIBLE ENTRANCE; (2) AN ACCESSIBLE ROUTE TO THE ALTERED AREA; (3) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE ACCESSIBLE UNISEX RESTROOM; (4) ACCESSIBLE TELEPHONES; (5) ACCESSIBLE DRINKING FOUNTAINS; AND (6) WHEN POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH AS PARKING, SIGNS, STORAGE AND ALARMS. §11B-202.4 7.ALTERATIONS TO A QUALIFIED HISTORIC BUILDING OR FACILITY SHALL COMPLY WITH CHAPTER 11B UNLESS IT WILL THREATEN OR DESTROY THE HISTORICAL SIGNIFICANCE OR CHARACTER-DEFINING FEATURES OF THE BUILDING OR PROPERTY. IN THOSE CASES, ALTERNATIVE PROVISIONS SHALL BE APPLIED ON AN ITEM-BY-ITEM OR CASE-BY-CASE BASIS WITH SUFFICIENT WRITTEN DOCUMENTATION. §11B-202.5, SHBC 8-602 8.NOTE ON PLAN: PUBLIC ACCOMMODATIONS SHALL MAINTAIN IN OPERABLE WORKING CONDITION THOSE FEATURES OF FACILITIES AND EQUIPMENT THAT ARE REQUIRED TO BE ACCESSIBLE TO AND USEABLE BY PERSONS WITH DISABILITIES. ISOLATED OR TEMPORARY INTERRUPTIONS IN SERVICE OR ACCESSIBILITY DUE TO MAINTENANCE OR REPAIRS SHALL BE PERMITTED. §11B-108 B.BUILDING BLOCKS FLOOR OR GROUND SURFACES 1.FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM, AND SLIP RESISTANT. §11B-302.1 2.CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE ½ INCH MAXIMUM. §11B-302.2, FIGURE 11B-302.2 CHANGES IN LEVEL 3.VERTICAL CHANGES IN LEVEL FOR FLOOR OR GROUND SURFACES MAY BE ¼ INCH HIGH MAXIMUM AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL GREATER THAN ¼ INCH AND NOT EXCEEDING ½ INCH IN HEIGHT SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. §11B-303, FIGURES 11B-303.2 & 11B-303.3 4.CHANGES IN LEVEL GREATER THAN ½ INCH IN HEIGHT SHALL BE RAMPED AND SHALL COMPLY WITH THE REQUIREMENTS OF 11B-405 RAMPS OR 11B-406 CURB RAMPS AS APPLICABLE. §11B-303 5.ABRUPT CHANGES IN LEVEL EXCEEDING 4 INCHES IN A VERTICAL DIMENSION BETWEEN WALKS, SIDEWALKS OR OTHER PEDESTRIAN WAYS AND ADJACENT SURFACES OR FEATURES SHALL BE IDENTIFIED BY WARNING CURBS AT LEAST 6 INCHES IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE OR BY GUARDS OR HANDRAILS WITH A GUIDE RAIL CENTERED 2 INCHES MINIMUM AND 4 INCHES MAXIMUM ABOVE THE SURFACE OF THE WALK OR SIDEWALK. THESE REQUIREMENTS DO NOT APPLY BETWEEN A WALK OR SIDEWALK AND AN ADJACENT STREET OR DRIVEWAY. § 11B-303.5 TURNING SPACE 6.CIRCULAR TURNING SPACES SHALL BE A SPACE OF 60 INCHES DIAMETER MINIMUM AND MAY INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH 11B-306 KNEE AND TOE CLEARANCE. §11B-304.3.1 7.T-SHAPED TURNING SPACES SHALL BE A T-SHAPED SPACE WITHIN A 60 INCH SQUARE MINIMUM WITH ARMS AND BASE 36 INCHES WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF OBSTRUCTIONS 12 INCHES MINIMUM IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES MINIMUM. §11B-304.3.2, FIGURE 11B-304.3.2 KNEE AND TOE CLEARANCE 8.FOR LAVATORIES AND BUILT-IN DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, TOE CLEARANCE SHALL BE PROVIDED THAT IS 30 INCHES IN WIDTH AND 9 INCHES IN HEIGHT ABOVE THE FINISH FLOOR OR GROUND FOR A DEPTH OF 19 INCHES MINIMUM. §11B-306.2.1 9.TOE CLEARANCE SHALL EXTEND 19 INCHES MAXIMUM UNDER LAVATORIES FOR TOILET AND BATHING FACILITIES AND 25 INCHES MAXIMUM UNDER OTHER ELEMENTS. § 11B-306.2.2 10.AT LAVATORIES IN TOILET AND BATHING FACILITIES, KNEE CLEARANCE SHALL BE PROVIDED THAT IS 30 INCHES IN WIDTH FOR A DEPTH OF 11 INCHES AT 9 INCHES ABOVE THE FINISH FLOOR OR GROUND AND FOR A DEPTH OF 8 INCHES AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND INCREASING TO 29 INCHES HIGH MINIMUM ABOVE THE FINISH FLOOR OR GROUND AT THE FRONT EDGE OF A COUNTER WITH A BUILT-IN LAVATORY OR AT THE FRONT EDGE OF A WALL-MOUNTED LAVATORY FIXTURE. §11B- 306.3.3, FIGURE 11B-306.3(C) 11.AT DINING AND WORK SURFACES REQUIRED TO BE ACCESSIBLE, KNEE CLEARANCE SHALL BE PROVIDED THAT IS 30 INCHES IN WIDTH AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND FOR A DEPTH OF AT LEAST 19 INCHES. §11B-306. PROTRUDING OBJECTS 12.EXCEPT FOR HANDRAILS, OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND LESS THAN 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL PROTRUDE NO MORE THAN 4 INCHES HORIZONTALLY INTO THE CIRCULATION PATH. HANDRAILS MAY PROTRUDE 4½ INCHES MAXIMUM. §11B-307.2, FIGURE 11B-307.2 13.FREESTANDING OBJECTS MOUNTED ON POSTS OR PYLONS SHALL OVERHANG CIRCULATION PATHS NO MORE THAN 12 INCHES WHEN LOCATED FROM 27 TO 80 INCHES ABOVE THE FINISH FLOOR OR GROUND. §11B-307.3, FIGURE 11B-307.3(A) 14.PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES. §11B-307.5 15.LOWEST EDGE OF A SIGN OR OTHER OBSTRUCTION, WHEN MOUNTED BETWEEN POSTS OR PYLONS SEPARATED WITH A CLEAR DISTANCE GREATER THAN 12 INCHES, SHALL BE LESS THAN 27 INCHES OR MORE THAN 80 INCHES ABOVE THE FINISH FLOOR OR GROUND. §11B-307.3, FIGURE 11B-307.3(B) 16.VERTICAL CLEARANCE SHALL BE AT LEAST 80 INCHES HIGH ON CIRCULATION PATHS EXCEPT AT DOOR CLOSERS AND DOOR STOPS, WHICH MAY BE 78 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-307.4 17.GUARDRAILS OR OTHER BARRIERS WITH A LEADING EDGE LOCATED 27 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE ON CIRCULATION PATHS IS LESS THAN 80 INCHES HIGH. § 11B-307.4, FIGURE 11B-307.4 18.WHERE A GUY SUPPORT IS USED WITHIN EITHER THE WIDTH OF A CIRCULATION PATH OR 24 INCHES MAXIMUM OUTSIDE OF A CIRCULATION PATH, A VERTICAL GUY BRACE, SIDEWALK GUY OR SIMILAR DEVICE SHALL BE USED TO PREVENT A HAZARD OR AN OVERHEAD OBSTRUCTION. §11B-307.4.1, FIGURE 11B-307.4.1 REACH RANGES 19.ELECTRICAL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF A ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. §11B-308.1.1 20.ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED WITHIN ALLOWABLE REACH RANGES. LOW REACH SHALL BE MEASURED TO THE BOTTOM OF THE OUTLET BOX AND HIGH REACH SHALL BE MEASURED TO THE TOP OF THE OUTLET BOX. §11B-308.1.2. 21.HIGH FORWARD REACH THAT IS UNOBSTRUCTED SHALL BE 48 INCHES MAXIMUM AND THE LOW FORWARD REACH SHALL BE 15 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. §11B-308.2.1, FIGURE 11B-308.2.1 22.HIGH FORWARD REACH SHALL BE 48 INCHES MAXIMUM WHERE THE REACH DEPTH IS 20 INCHES OR LESS AND 44 INCHES MAXIMUM WHERE THE REACH DEPTH EXCEEDS 20 INCHES. HIGH FORWARD REACH SHALL NOT EXCEED 25 INCHES IN DEPTH. §11B-308.2.2, FIGURE 11B-308.2.2 23.HIGH SIDE REACH SHALL BE 48 INCHES MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 INCHES MINIMUM ABOVE THE FINISH FLOOR WHERE THE SIDE REACH IS UNOBSTRUCTED OR THE DEPTH OF ANY OBSTRUCTION DOES NOT EXCEED 10 INCHES. §11B-308.3.1, FIGURE 11B-308.3.1 RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt ACCESSIBILITY NOTES G401 HANDICAPPED BLUE COLOR, BACKGROUND #15090 FED. STD. 595C OR EQ. WHITE HIGHWAY PAINT 2 COATS, 3" WIDE TYP. 5" ( B U I L D I N G E N T R A N C E S I G N A G E ) 3' - 0 " ( P A R K I N G ) 5" (BUILDING ENTRANCE SIGNAGE) 3' - 0" (PARKING) 6'-8" MIN. NOTES: 1. SIGN TO BE REFLECTORIZED PORCELAIN STEEL. 2. BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE OR, + 80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL. 3. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS. 4. ARROW SHALL POINT IN THE DIRECTION OF THE PATH OF TRAVEL 1/2" RADIUS TYPICAL WHITE ON BLUE BACKGROUND 2" DIA. GALV. POLE 12" (MIN.) 12 " ( M I N . ) 6'-8" MIN. UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT: NOTES: 1. SIGN TO BE REFLECTORIZED PORCELAIN STEEL WITH BEADED TEXT 2. BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL. 3. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS. 4. SIGN TO BE PROVIDED AT ALL ENTRY DRIVEWAYS 5. CITY OF XX POLICE DEPARTMENT OR BY CALLING: (XXX) XXX-XXXX. SIGN LETTERING SHALL BE NOT LESS THAN 1" IN HEIGHT(REFER TO NOTE #5) 2" DIA. GALV. POLE 24" RECOMMENDED 17" (MIN.) 24 " R E C O M M E N E D E D 22 " ( M I N . ) EQUAL TYP. EQUAL TYP. (E) 9'-0" STANDARD STALL 5'-0"3'-0"2' -0" 18 ' -0" 36"36 " EQUAL TYP. EQUAL TYP. (E) 9'-0" STANDARD STALLTYP.RA MP DO WN RA MP DO WN NO PARKING (E) 4" WIDE, PAINTED BLUE STRIPES (E) 12" HIGH LETTERING INDICATING "NO PARKING," PAINTED TRAFFIC WHITE (E) 4'-0" LONG CONCRETE WHEEL STOP (TYP.) NOTE: SLOPE OF PARKING STALL AND ADJACENT ACCESSIBLE AISLE NOT TO EXCEED 2% SLOPE IN ANY DIRECTION (E) 4" WIDE, PAINTED BLUE STRIPE SEE SITE PLAN FOR STALL(S) CONFIGURATION. 4'-4" MIN. 4' - 0 " M I N . A L ES S T H A N 6 0 " W ID E 6 0 " MI N. 6 0 " M I N . 6 0 " M I N . 6 0 " MI N. 6 0 " M I N . 2 0 0' M A X 2 0 0 ' M AX 2 0 0 ' M A X 4 0 0 ' M A X 6 0 " M IN . 60" M IN . 60" M IN . PASSING SPACE (2% MAX CROSS-SLOPE) LEVEL REST AREA (2% MAX SLOPE IN ANY DIRECTION) 4 8 " M I N . 4 8 " M I N . LESS THAN 60" WIDE 2 % M A X 5% M A X 5% M AX LEVEL TURNING AREA (2% MAX SLOPE IN ANY DIRECTION) RESTING AND PASSING AREAS NOTES: AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60 INCHES PROVIDES PASSING SPACES AT INTERVALS OF 200 FEET MAXIMUM. THE PASSING SPACES ARE EITHER A SPACE 60 INCHES MINIMUM BY 60 INCHES MINIMUM, OR AN INTERSECTION OF TWO WALKING SURFACES THAT PROVIDE A COMPLIANT T-SHAPE TURNING SPACE WHERE THE BASE AND ARMS OF THE T-SHAPE SPACE EXTEND 48 INCHES MINIMUM BEYOND THE INTERSECTION. 11B-403.5.3 G A F E D C B C - RAMP WITH TURNING PLATFORM CURB RAMPS RAMP WITH INTERMEDIATE SWITCHBACK PLATFORM STRAIGHT RAMP RUN HANDRAIL AT RAMPS RAMP SECTION TRUNCATED DOMES MI N . 48" 3' -0" 12" 36 " 12" 4"MA X. 30 " 43 " 36 " 36 " 48" MIN. 48" MIN. WIDTH LANDING RAMP LANDING 27 " M A X . 27 " M A X . 2.35" .6 5 " M I N . 2. 3 5 " . 48"60" 48 " 6'-6" 48" 3' -0" 3' -0" 4'-0" 3' -0" 3' -0" 60" MIN. 72" MIN. 72" MIN. 72" MIN. 72" MIN.60" MIN. 72" MIN. DN . MIN. NOTE: 1.SHADED AREAS OF RAMP MUST HAVE DETECTABLE WARNING SURFACE CROSS SLOPE OF LANDING 2.AREAS SHALL NOT EXCEED 2% IN ANY DIRECTION. 30" MAX. RISE (TYP.) TO F I N I S H F L O O R HANDRAILS MUST EXTEND A MINIMUM OF12" OF LEVEL DISTANCE (PARALLEL TOLANDING SURFACE) BEYOND TOP AND BOTTOM OF THE RAMP ENDS THE RAMP ENDS BEFORE THEY ARE RETURNED GUARD RAIL IN ACCORDANCE WITH CBC 1015 VARIES (30' MAX.) 60" MIN. 30" MAX. RISE (TYP.) AT LEAST AS WIDE AS RAMP RUN WIDTH MUST BE A MINIMUM OF 60" WHEN SERVING AN OCCUPANCY 300 OR MORE 1-1/4" TO 1-1/2" DIA. HANDRAIL AT RAMPS EDGE PROTECTION -IN FORM OF A BARRIER: 2" HIGH CURB (6" HIGH WARNING CURB WHERE A DROP OF 4" OR MORE OCCURS) < 4" AND < 30" ADJACENT HAZARD 72" MIN. 60" MIN. INTERMEDIATE PLATFORM AT LEAST AS WIDE AS RAMP RUN 30" MAX. RISE (TYP.) 60" MIN. LANDING GUIDE CURB OR WARNING CURB POST @ 4'-0" O.C. MAX 24" MIN. OF STRAIGHT CURB INTERMEDIATE TURNING POSITION VARIES (30' MAX.) WHEN DOOR SWINGS ONTO LANDING: 42" MIN. PLUS DOOR WIDTH VARIES (30' MAX.) WHEN DOOR SWINGS ONTO LANDING: 42" MIN. PLUS DOOR WIDTH 60" MIN. AT LEAST AS WIDE AS RAMP RUN 60" MIN.VARIES (30' MAX.) WHEN DOOR SWINGS ONTO LANDING: 42" MIN. PLUS DOOR WIDTH 60" MIN.VARIES (30' MAX.) ADJACENT HAZARD 0.2" TOP DIAMETER 0.45" -0.47" MAX BOTTOM DIAMETER 0.9" -0.92" MAX PLAN VIEW ENLARGED ELEVATION VIEW DN . DN . PLTR.PLTR. DN. TYP. MI N . MIN. 2% S L O P E NOTE: SURFACE WILL REQUIRE 36" SECTION OF TRUNCATED DOMES IF LANDING SURFACE ADJOINS VEHICULAR TRAFFIC WAY (SEE DETAIL "B") PAINT CURB SAFETY YELLOW (2 COATS), TYP. LINE OF OBSTRUCTION OR EDGE OF WALK AREA, AS OCCURS, TYP. LINE OF FRONT OF REQ'D PARKING SPACE 1:10 MAX. SLOPE (TYPICAL) 1:12 SLOPE MAX. TYP. LINE OF OBSTRUCTION OR EDGE OF WALK AREA AS OCCURS, TYP. MIN. WALK AREA MIN. DN. DETECTABLE WARNINGS SHALL BE LOCATED SO THE EDGE NEAREST THE CURB IS 6 INCHES (152 mm) MINIMUM & 8 INCHES (203 mm) MAXIMUM FROM THE DEMARCATION LINE AT THE FACE OF THE CURB, BETWEEN THE CURB & THE GUTTER, STREET OR HIGHWAY (CBC 11B-705.1.2.2.1) 1:10 MAX. SLOP E (TYPI CAL) 1:12 SLOPE MAX. TYP. 1:12 SLOPE MAX. TYP. NOTES: 1. DETECTABLE WARNING SURFACE SHALL BE YELLOW CONFORMING TO FS 33538 OF FEDERAL STANDARD 595C 2. MATERIAL USED SHALL BE RECESSED INTO WALKING SURFACE 3. DETECTABLE WARNING SURFACE SHALL CONTRAST VISUALLY WITH ADJACENT WALKING SURFACES EITHER LIGHT-ON-DARK OR DARK-ON-LIGHT 4. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 24, PART 1, CHAPTER C B A 27 " M A X . 30° MAX.30° MAX. . 1 1 / 2 M I N 12" TW + 12" MIN.36 " 12" MIN. 12" TW + 12" MIN. 36 " 12" MIN. 27 " M A X . 1-1/4" MAX.1-1/4" MAX. TW TW 2 1/4 MAX2 1/4 MAX1 1/2 MIN -2 MAX 1 1/2 12"12" MIN. TO F I N I S H F L O O R HANDRAIL EXTENSIONS AT STAIRWAY ACCEPTABLE STAIR NOSING SOLID RISER, TYPICAL 1/2" RADIUS MAX. RADIUS NOSING BEVELED NOSING 1/2" BEVEL MAX. ROUNDED OR BEVELED NOSING, TYPICAL VISUAL WARNING STRIPS SHALL BE 2" MIN. (4" MAX.) WIDTH AND INSTALLED 1" MAX. FROM EDGE OF THE TOP AND BOTTOM TREADS OF INTERIOR STAIRS, AND ON ALL TREADS OF EXTERIOR STAIRS.BOTTOM LANDING TOP LANDING VISUAL WARNING STRIPS SHALL BE 2" MIN. (4" MAX.) WIDTH AND INSTALLED 1" MAX. FROM EDGE OF THE TOP AND BOTTOM TREADS OF INTERIOR STAIRS, AND ON ALL TREADS OF EXTERIOR STAIRS.BOTTOM LANDING TW = TREAD WIDTH TW = TREAD WIDTH TO F I N I S H F L O O R TOP LANDING 1-1/2"TO 1-1/2" 1-1/4" 3" MAX. 18 " M I N . 1 1 / 2 " MI N . NON-CIRCULAR CROSS SECTION CLEARANCE & GRIPPING SURFACES CIRCULAR CROSS SECTION 4-6 1/4 PERIMETER PLAN VIEW STAIR GENERAL NOTES: RISER EIGHT AND TREAD DEPT: ·RISER HEIGHT: 7" MAX AND 4" MIN. ·RECTANGULAR TREAD DEPTH: 11" MIN. DIMENSIONAL UNIFORMITY: STAIR TREADS AND RISERS SHALL BE OF UNIFORM SIZE AND SHAPE. THE TOLERANCE BETWEEN THE LARGEST AND SMALLEST RISER HEIGHT OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTH SHALL NOT EXCEED 3/8". WALKING SURFACE: EXTERIOR WALKING SURFACE OF TREADS SHALL BE SLOPED FOR DRAINAGE NOT STEEPER THAN 2% IN ANY DIRECTION. GENERAL NOTE: PROVIDE SMOOTH, NON ABRASIVE SURFACE BEHIND HANDRAILS. B A VAN STALL STANDARD STALL VAN ACCESSIBLE 5'-0" 18 ' -0" MI N . 12'-0"9'-0" 4' -0" MI N . CL R . 1' -0" VE H I C L E OV E R H A N G 1' -6" 1'-0" 1' -6"3'-0"TYP.EV CHARGING ONLY EV CHARGING ONLY ACCESSIBLE ROUTE CLEAR FLOOR SPACE EV CHARGER STANDARD ACCESSIBLE EVCS EVCS NOT REGULATED BY SECTION 11B-812VAN ACCESSIBLE EVCS ACCESSIBLE ROUTE NO PARKI NG 12" HIGH LETTERING INDICATING "NO PARKING," PAINT 2 COATS TRAFFIC WHITE 12" HIGH LETTERING INDICATING "EV CHARGING ONLY," PAINT 2 COATS TRAFFIC WHITE EQUIPMENT SPACE 1-1/2" RADIUS TYPICAL RED ON WHITE BACKGROUND "P" SHALL BE BLACK NOTES: 1. SIGN TO BE REFLECTORIZED PORCELAIN STEEL. 2. BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFACE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL. 3. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS. VAN ACCESSIBLE SIGN WHERE APPLICABLE ELECTRIC VEHICLE CHARGING SIGN 1/2" RADIUS TYPICAL ELETCRIC VEHICLE CHARGING PARKING STALLELETCRIC VEHICLE CHARGING SIGN E F B A B C 48" MIN. 48 " M A X . 15 " MI N . 48 " 15 " M I N . 48" 30 " M I N . 1/ 4 " MA X . 48" MIN. CLR. 1/ 2 "MA X. 1/ 4 " MA X . 1/ 4 " MA X . 30" 48 " 30"10" MA X. 2 1 NOTES: 1.CHANGES IN LEVEL BETWEEN 1/4" HIGH MIN. AND 1/2" HIGH MAX. SHALL BE BEVELED WITH A SLOPE NOT STEEPER THAN 1:2. 2.1/4" MAXIMUM VERTICAL LEVEL CHANGE. HIGH FORWARD REACH LIMITS CLEAR FLOOR SPACE -FRONT APPROACH SIDEWALK OBSTRUCTIONS LEVEL CHANGES CURB (TYP.) STREET (TYP.) SIDEWALK HIGH AND LOW SIDE REACH LIMITS CLEAR FLOOR SPACE PARALLEL APPROACH 80 " MI N . 27 " MA X . 4" MAX. D A X NOTES: 1. X SHALL BE < 25 INCHES; Z SHALL BE EQUAL TO X. 2. WHEN X < 20 INCHES, THEN Y SHALL BE 48 INCHES MAXIMUM. 3. WHEN X IS 20 TO 25 INCHES, THEN Y SHALL BE 44 INCHES MAXIMUM. 48" 30 " M I N . 48" Y Z Z X 34 " M A X . 30"24" MAX. 46 " M A X . MAXIMUM FORWARD REACH OVER AN OBSTRUCTION MAXIMUM SIDE REACH B D E F A C 18" MIN. 12" MIN. 48 " M I N I M U M DOOR TYPE: A. REQUIRED EXIT DOORWAY(S) ARE OF A SIZE TO PERMIT INSTALLATION OF A DOOR A MINIMUM 3' IN WIDTH, 6'-8" IN HEIGHT B. EXIT DOOR IS CAPABLE OF OPENING A MINIMUM OF 90 DEGREES C. THE CLEAR WIDTH OF THE DOORWAY IS 32" MINIMUM. D. DOUBLE DOORS/AUTOMATIC DOORS -AT LEAST ONE DOOR MUST COMPLY WITH DOOR TYPE ITEM B AND C ABOVE E. BOTTOM 10" OF DOOR (EXCEPT SLIDING DOORS) HAS A SMOOTH, UNINTERRUPTED SURFACE THAT ALLOWS DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION F. EFFORT TO OPERATE DOOR IS WITHIN PRESSURE ALLOWED. INTERIOR AND EXTERIOR DOORS -5 POUNDS MAXIMUM PRESSURE TO OPERATE. FIRE DOORS -15 POUNDS MAXIMUM PRESSURE TO OPERATE G. TWO DOORS A SERIES PROVIDE A MINIMUM OF 48" CLEAR SPACE FROM ANY DOOR IN ANY POSITION 48 " M I N I M U M 48 " M I N I M U M 12" MIN. 1/ 2 " 60 " M I N I M U M 48" MINIMUM 54" PREFERRED LEVER, LOOPED AND PUSH BAR DOOR HARDWARE 10" MIN. BOTTOM RAIL RUBBER BUMPER ON CHAIR PROVIDE THIS ADDITIONAL SPACE IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER 1/2" MAX. PILE HEIGHT COMPRESSED CARPET 1/4" MAX. BELOW THRESHOLD THRESHOLD FIN. FLOOR LEVEL PROVIDE THIS ADDITIONAL SPACE IF DOOR IS EQUIPPED WITH BOTH A LATCH AND A CLOSER DOOR HARDWARE & MOUNTING HEIGHTS THRESHOLD TRANSITION BETWEEN FLOOR FINISHES VESTIBULES / TWO DOORS IN SERIES TYPICAL DOOR ELEVATION HEIGHTS 24" MIN. EXTERIOR 18" MIN. INTERIOR SURFACE SLOPE NOT TO EXCEED 2% 12" MINIMUM IF DOOR HAS BOTH A CLOSER AND A LATCH SURFACE SLOPE NOT TO EXCEED 2% TYPICAL DOOR LANDING CLEARANCES 2 1 1/2" MAX. 1/4" MAX. GROUT BELOW THRESHOLD HARDWARE: A. HANDLES, PULL LATCHES, LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE OPERATE B. LATCHING AND LOCKING DOORS THAT ARE HAND OPERATED AND WHICH ARE IN A PATH OF TRAVEL ARE OPERABLE BY LEVER TYPE, PANIC BARS, PUSH-PULL ACTIVATION BARS, U-SHAPED HANDLES OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN EGRESS DIRECTION C. 11B-404.2.7 OPENING HARDWARE IS CENTERED BETWEEN 34" AND 44" ABOVE FINISH FLOOR D. 11B-404.2.8.1 -DOOR CLOSERS AND GATE CLOSERS, IF PRESENT, SHALL BE ADJUSTED SO THAT FROM AN OPENING POSITION OF 90°, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12° FROM THE LATCH IS 5 SECONDS MINIMUM 11B-404.2.8.2 -DOOR AND GATE SPRING HINGES, IF PRESENT, SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70°, THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM THRESHOLD A. FLOOR(S) OR LANDING(S) ARE NOT MORE THAN 1/2" LOWER THAN THE TOP OF THE THRESHOLD OF THE DOORWAY. B. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" IS BEVELED AT A MAXIMUM GRADIENT OF 1:2. C. RECESSED DOOR MATS ARE ADEQUATELY ANCHORED TO PREVENT INTERFERENCE WITH OF 1:2. D. CARPET AND CARPET TILES ARE SECURELY ATTACHED AND HAVE LEVEL LOOP, TEXTURED LOOP, LEVEL-CUT PILE OR LEVEL-CUT/UNCUT PILE WITH PILE NOT EXCEEDING 1/2" IN HEIGHT. E. EXPOSED EDGES OF CARPET ARE FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. 64 " 43 " 42 " 38 " F.F. DOOR & FRAME, WHERE OCCURS VIEWER ℄OF DR. DEADLOCK OR PUSH PLATE ℄OF DOOR PULL GRIP AND OF PUSH-PULL BAR ℄OF LEVER HANDLE, LATCH AND CROSS BAR ON FIRE EXIT DEVICE 6'-8" MIN. PARKING ONLY MINIMUM FINE $250 VAN ACCESSIBLE NOTES: 1. SIGN TO BE REFLECTORIZED WITH AN AREA OF THE SIGN(S) IS NOT SMALLER THAN 70 SQUARE INCHES 2. SIGN TO BE CENTERED AT THE INTERIOR END OF PARKING SPACE 3. BOTTOM OF SIGN TO BE +60" MINIMUM ABOVE FINISH FLOOR OR GROUND SURFAQCE OR, +80" ABOVE FINISHED SURFACE WHEN LOCATED IN THE PATH OF TRAVEL 4. SIGN TO CONFORM TO ALL CURRENT, FEDERAL, STATE, LOCAL CODES AND / OR REGULATIONS 5. SIGN TO BE PROVIDED AT ALL PARKING SPACES RESERVED FOR PERSONS WITH DISABILITIES WHITE ON BLUE BACKGROUND TYPICAL 1/2" RADIUS TYPICAL VAN ACCESSIBLE SIGN WHERE APPLICABLE 2" DIA. GALV. POLE RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt ACCESSIBILITY DETAILS G403 3/4" = 1'-0"1ACCESSIBLE SYMBOL 1/8" = 1'-0"2 ACCESSIBLE PATH OF TRAVEL 1/8" = 1'-0"3 UNAUTHORIZED VEHICLE WARNING SIGNS 1/8" = 1'-0"4ACCESSIBLE PARKING STALL 1" = 10'-0"5PASSING SPACES 1" = 10'-0"6 GENERAL RAMP REQUIREMENTS 1" = 10'-0"7STAIR DETAILS 1" = 10'-0"8 ELECTRIC VEHICLCLE CHARGING PARKING STALL & SIGNAGE 1" = 10'-0"9WALKS & SIDEWALKS 1" = 10'-0"10PROTRUDING OBJECTS 1" = 10'-0"11REACH REQUIREMENTS 1" = 10'-0"12 GENERAL DOOR REQUIREMENTS 1/8" = 1'-0"14 ACCESSIBLE PARKING STALL SIGNAGE N O T U S E D N O T U S E D 1 2 A B C D E F G H I 44 " 4" 8" 15 " MI N . 48 " M A X . 48 " M A X . DO O R H E I G H T M I N U S 8 " 80 " ( O R 6 " B E L O W CE I L I N G W H I C H E V E R I S L O W E R ) 48 " M A X . 48 " M A X 48 " M A X . TO P OF H A N D L E 34 " M A X ELECTRICAL RECEPTACLE, SWITCH AND CONTROLS FIRE CONTROL DEVICES COUNTER F.F. CARD READER, LOCAL ALARM, ARMING OR INTERCOM STATION, WALL PHONE OUTLET ELECTRICAL OR COMMUNICATION OUTLET ABOVE COUNTER ELECTRICAL OR COMMUNICATION OUTLET LIGHT SWITCH THERMOSTAT ELECTRO MAGNETIC DOOR HOLD-OPEN AUDIBLE & VISUAL FIRE ALARM OR SECURITY STROBE LIGHT MANUAL FIRE ALARM PULL STATION FIRE EXTINGUISH ER FIRE EXTINGUISHER IN CABINET BACK SPLASH A B C D E G H I JF 40 " M A X . T O H I G H E S T OP E R A B L E P A R T 33 " -36 " T. O . GR I P P I N G OF SU R F A C E 19 " M I N . 1 1 / 2 " M I N . 12 " MI N . 4" MAX. 40 " M A X . B . O . RE F L E C T I V E SU R F A C E OV E R A CO U N T E R O R LA V . 35 " M A X . A N Y WH E R E E L S E 19 " M A X ACCESSIBLE TOWEL DISPENSER ACCESSIBLE SANITARY NAPKIN/TAMPON VENDOR ACCESSIBLE SOAP DISPENSER ACCESSIBLE SEAT COVER DISPENSER GRAB BARS SPACING OF GRAB BAR ACCESSIBLE ROLL TOILET TISSUE DISPENSER ACCESSIBLE SANITARY NAPKIN DISPOSAL POINT OF DISPENSI NG MIRROR MOUNTING HEIGHTS PAPER TOWEL DISPENSER 48" MIN. 2 1 / 2 " MA X . 20 " M I N . 24 " M A X . 17 " M I N . 19 " M A X . 18 " M I N . 2" MA X . 40 " M I N . 4 8 " M A X . H E I G H T 15 " L O W E S T RE A C H R A N G E A. ACCESSIBLE BENCH PLAN B. ACCESSIBLE BENCH SECTION C. ACCESSIBLE LOCKER SECTION NOTE: · CLEAR FLOOR OR GROUND SPACE SHALL BE PROVIDED AND POSITIONED AT THE END OF THE BENCH SEAT AND PARALLEL TO THE SHORT AXIS OF THE BENCH · BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL ALONG ITS LONG DIMENSION · BENCH SHALL BE AFFIXED TO THE WALL OR FLOOR · ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A FORCE OF 250 POUNDS IS APPLIED · 30"x48" WHEELCHAIR ACCESS AT EITHER END OF ACCESSIBLE BENCH SHELF 60" CLR. MIN. 34 " M I N . CL E A R 4" M A X 35"-37" 60 " M I N . 6 0 " C L E AR F L O O R S P A C E 44 ' M I N . 60 " M I N . M A N E U V E R I N G S P A C E 36 " M I N . WH E N D O O R S W I N G S I N 59 " M I N . @ F L O O R M O U N T E D W A T E R C L O S E T 60" CLR. MIN. 32" MIN. CLR. 4" MAX. 48 " M I N . M A N E U V E R I N G S P A C E 6" CLEAR 59 " M I N . @ F L R M O U N T E D W A T E R C L O S E T 56 " M I N . @ W A L L M O U N T E D W A T E R C L O S E T G F BA C D E 17" MIN. 34 " M A X . 29 " M I N . 6" MAX. TOE CLEARANCE 8" 9" MI N . 24" MIN. 48" 48" MIN. CLR. TO ADJ. WALL 33 " - 36 " T. O G R I P P I N G S U R F A C E 54" MIN 17"-19" 8" 27 " M I N . 17"-18" 17"-18" 11" MIN. 12" MAX. 40 " M A X . T O R E F L E C T I V E SU R F A C E 39 " M I N . 41 " M A X 18 " M I N . 39" MIN. -41" MAX. 25" MAX. 18"MIN. 34 " M A X . 40 " M A X . W H E N M O U N T E D OV E R C O U N T E R O R L A V . 33 " -36 " T. O . G R I P P I N G OF S U R F A C E 6" MAX.42" 12" MIN. 17"-18" 1-1/ 2 " MI N . 40 " M A X . W H E N M O U N T E D OV E R C O U N T E R O R L A V . 7"-9" 19 " M I N . TO O P E N ' G STRUCTURAL STRENGTH: ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHERE A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS (1112 N) IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER MOUNTING DEVICE, OR SUPPORTING STRUCTURE. 42" MIN. MIN. KNEE CLEARANCE SURFACE MOUNTED DOUBLE- ROLL TOILET TISSUE DISPENSER PROVIDE BACKING FLUSH VALVE OR VALVE SHALL BE ON 'WIDE SIDE" SURFACE MOUNTED SANITARY NAPKIN DISPOSAL WHERE OCCURS SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER SURFACE MOUNTED TOILET SEAT-COVER DISPENSER SELF-CLOSING DOOR SELF-CLOSING DOOR ELEVATION ELEVATION SIDE OPENING DOORSINGLE ACCOMODATION SIDE FRONT DOOR AMBULATORY VERTICAL GRAB BAR WHERE OCCURS. ℄. PLUMBEREX, PRO-EXTREME SERIES X4333 KIT INCLUDES: P- TRAP COVER, TWO (2) SUPPLY COVERS FIN. FACE OF WALL 36" MIN. ELEVATION SURFACE MOUNTED PAPER DISPENSER 7 1 3 2 6 8 ℄. SURFACE MOUNTED SANITARY NAPKIN 5 4 11B.306 Knee & Toe Clearance 17 " M I N . 19 " M A X E F G 60" CLR. MIN. 16 G4 0 4 19 " MA X . 32 " M I N . CL R . 60" C L E A R FL O O R S P A C E 48 " M I N . 18" FLUSH HANDLE OR VALVE SHALL BE ON WIDE SIDE 30"x48" CLR. FLOOR SPACE 17"-18" B A B - 34 " M A X . 6-1/ 2 " M A X . SI N K DE P T H 27 " M I N . K N E E CL E A R A N C E 19" DEPTH KNEE CLEARANCE 24" MAX. 3'-0" CLEAR 18" MIN. 30" MIN 19 " M A X 8"MIN 11"MIN 9" M I N SECTION PLAN ℄ SINK ATTACH TOE KICK TO CABINET DOOR UPPER CABINETS WHERE OCCURS LEVER HANDLE FOR FAUCET -SEE PLUMBING DWGS NOTE: INSULATE DRAIN & HOT WATER PIPES A B 60 " M A X 48 " M I N 60 " M A X 48 " M I N 1 THRU 2 NO ROOF ACCESS STAIR 1 1 1 THRU 2 NO ROOF ACCESS STAIR 1 2 1ST FLOOR SIGN 2ND FLOOR SIGN ADD RAISED STAR TO FLOOR IDENTIFICATION SIGNS, REQUIRED ON FIRST FLOOR SIGN ONLY FIN. FLR. FIN. FLR. GROUND FLOOR UPPER OR LOWER FLOORS BRAILLE BRAILLE A B C D 60 " M A X 4" 4" 60 " M A X . T O B A S E L I N E O F RA I S E D C H A R A C T E R S 48 " M I N . T O B A S E L I N E O F TA C T I L E C H A R A C T E R S 6" 6" EQ . EQ . 6" 6" EQ . EQ . 60 " M A X . T O B A S E L I N E O F RA I S E D C H A R A C T E R S 48 " M I N . T O B A S E L I N E O F TA C T I L E C H A R A C T E R S 6" 6" EQ . EQ . 60 " M A X . T O B A S E L I N E O F RA I S E D C H A R A C T E R S 48 " M I N . T O B A S E L I N E O F TA C T I L E C H A R A C T E R S 1 EXIT 2 EXIT ROUTE EXIT STAIRS DOWN FIN. FLR. 1ST LEVEL EACH ELEVATOR HOISTWAY ENTRANCE MUST HAVE RAISED FLOOR DESIGNATION CHARACTERS, SANS SERIF OR SIMPLE SERIF TYPE, 2" HIGH ON EACH DOOR JAMB CENTERED 60" AFF, AND THE SIGNS FOR THE MAIN ENTRY FLOOR MUST INCLUDE A RAISED STAR. THE CHARACTERS MUST BE WHITE ON A BLACK BACKGROUND. BRAILLE MUST BE PLACED BELOW THE CORRESPONDING RAISED CHARACTERS ADD RAISED STAR TO FLOOR IDENTIFICATION SIGNS, REQUIRED ON FIRST FLOOR SIGN ONLY 2ND LEVEL 1/8" THICK MATTE ACRYLIC SIGN COLOR TO BE VERIFIED ADA COMPLIANT GRADE 2 BRAILLE BEADS SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT SEPARATED 3/8 INCH MIN. 1/2 INCH MAX. FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH FROM RAISED BORDERS AND DECORATIVE ELEMENTS ADA COMPLIANT WHITE LETTERS. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASE LINE OF THE CHARACTER SHALL BE 5/8 INCH MIN. AND 2 INCH MAX. BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS SHALL BE 15 PERCENT MAXIMUM OF THE SAME LETTER "I" FIN. FLR. LOCATE AT GRADE LEVEL EXTERIOR EXIT DOOR 1/8" THICK MATTE ACRYLIC SIGN COLOR TO BE VERIFIED REFERENCE: CBC 11B-703. DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS 0.300 INCHES MIN. AND MAX., PER TABLE 11B-703.3.1 DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS 0.300 INCHES MIN. AND MAX., PER TABLE 11B-703.3.1 BRAILLE BRAILLE FIN. FLR. BRAILLE BRAILLE ADA COMPLIANT WHITE LETTERS. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASE LINE OF THE CHARACTER SHALL BE 5/8" MIN AND 2 INCH MAX BASED ON THE HEIGHT OF THE UPPER CASE LETTER "I". STROKE THICKNESS SHALL BE 15 PERCENT MAXIMUM OF THE SAME LETTER "I". FLOOR IDENTIFICATION SIGNS EXIT SIGNS EXIT ROUTE SIGNS FIN. FLR. 1/8" THICK MATTE ACRYLIC SIGN COLOR TO BE VERIFIED DISTANCE BETWEEN CORRESPONDING DOTS IN ADJACENT CELLS 0.300 INCHES MIN. AND MAX., PER TABLE 11B-703.3.1 BRAILLE ADA COMPLIANT WHITE LETTERS. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASE LINE OF THE CHARACTER SHALL BE 5/8" MIN AND 2 INCH MAX BASED ON THE HEIGHT OF THE UPPER CASE LETTER "I". STROKE THICKNESS SHALL BE 15 PERCENT MAXIMUM OF THE SAME LETTER "I". EXIT STAIRS SIGNS ADA COMPLIANT GRADE 2 BRAILLE BEADS SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT SEPARATED 3/8 INCH MIN. 1/2 INCH MAX. FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH FROM RAISED BORDERS AND DECORATIVE ELEMENTS. ADA COMPLIANT GRADE 2 BRAILLE BEADS SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT SEPARATED 3/8 INCH MIN. 1/2 INCH MAX. FROM ANY OTHER TACTILE CHARACTERS AND 3/8 INCH FROM RAISED BORDERS AND DECORATIVE ELEMENTS. 35 " M I N . A. F . F . 1/ 2 " M I N . 3/4" MIN. 48 " A . F . F . M A X F O R F R O N T AP P R O A C H 5 4 " A . F . F . M A X FO R P A R A L L E L A P P R O A C H 6' -0" M I N . 42 " 29 "60 " 5" 6' -0" M I N . NOTE: AUTOMATIC DOOR REOPENING DEVICE IS ACTIVATED IF AN OBJECT PASSES THROUGH EITHER LINE A OR LINE B. LINE A AND LINE B REPRESENT THE VERTICAL LOCATIONS OF THE DOOR REOPENING DEVICE NOT REQUIRING CONTACT. FLOOR LANDING NUMBERS ON BOTH SIDES OF DOOR JAMB 1 3 2 4 5 6NUMERAL HEIGHT MAIN ENTRY FLOOR DOOR CLOSE DOOR OPEN EMERGENCY ALARM EMERGENCY STOP HALL LANTERN CALL BUTTON ℄ B A ℄ ℄ BUTTON WIDTH HG W 12 " 14" MAXIMUM OCCUPANCY 76 1/8" THICK MATTE ACRYLIC SIGN COLOR TO BE BEIGE STANDARD BLACK LETTER GRAPHICS NOTE: 1) MOUNT SIGN IN A VISIBLE LOCATION BETWEEN 48" & 60" ABOVE FINISH FLOOR 2) VERIFY MAX OCCUPANCY WITH ARCHITECT ALL GENDER BRAILLE MEN WOMEN 3 2 1 B A C 6" 48 " M I N . T O L O W E S T LI N E O F B R A I L L E 60 " M A X . 12 " 3" EQ.EQ. AL I G N W I T H T O P O F A D J . F R A M E 12 " O R GR E A T E R 18"MI N. CLEA R EQ.EQ. 18 " M I N. CL E A R 18"MI N. CLEA R 6" 12 " 6" 12 " 6" 12 " EQ. 60 " M A X . B A S E L I N E O F H I G H E S T LE V E L O F R A I S E D C H A R A C T E R S 48 " M I N . T O L O W E S T LI N E O F B R A I L L E EQ EQ 60 " M A X . 58 " -60 " EQ. 18"MIN. CLEAR BRAILLE 45° F.F. EXIT EXIT WALL MOUNTED EXIT SIGN AT EXIT DOOR MO U N T O N S T R I K E S I D E W H E N DI M A B O V E DO O R H E A D < 1 2 " ℄ WALL OR OBSTRUCTION WHERE OCCURS CENTERED ON TACTILE CHARACTERS BRAILLE BRAILLE MI N . WOMEN'S ACCESSIBLE TOILET SIGNAGE MEN'S ACCESSIBLE TOILET SIGNAGE UNISEX / ALL GENDER ACCESSIBLE TOILET SIGNAGE MI N . MI N . ℄ ℄ CE N T E R R E S T R O O M S I G N WI T H I N 1 8 " O F D O O R F R A M E ℄ ℄ WALL OR OBSTRUCTION WHERE OCCURS SIGNAGE LOCATION AT TOILET ROOM DOOR EXIT, EXIT ROUTE, EXIT STAIRS & ROOM SIGNAGE TYPICAL LOCATION OF TACTILE SIGNS AT DOORS EXIT ROUTE BRAILLE ALL GENDERRESTROOM 27 " M I N . 36 " M A X . 3 2 " CLE A R F O R SI NG L E 18" MIN.19" MAX. 18" MIN.24" MAX. 6 " MI N . 6" MAX. 38 " M I N . T O 4 3 " M A X . 5" MAX. Hi-LO FOUNTAIN DESIGN NOTE: ILLUSTRATIONS SHOWN HERE ARE FOR DIMENSIONAL ACCESSIBILITY PURPOSES ONLY. A SECOND DRINKING FOUNTAIN SHOULD BE PROVIDED AT A MOUNTING HEIGHT SUITABLE TO PERSONS WITH LIMITED PHYSICAL BENDING ABILITY, ADJACENT TO THE ACCESSIBLE FOUNTAIN, MAINTAINING MINIMUM CLEARANCES NOTED AND AS REQUIRED. PROVIDE TEXTURED AREA OF CONTRASTING COLOR TO IDENTIFY WATER FOUNTAIN LOCATION. WHEN FOUNTAIN IS AT AN INTERIOR LOCATION, THE TEXTURED AREA SHALL ALSO BE OF DIFFERENT RESILIENCY THAN THAT OF THE ADJACENT FLOOR SURFACE FINISH. 11B-602 DRINKING FOUNTAINS: SHALL COMPLY WITH SECTION 11B-307 AND 11B-602. 11B-602.2: CLEAR FLOOR SPACE: UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH SECTION 11B-305 POSITIONED FOR A FORWARD APPROACH AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE COMPLYING WITH SECTION 11B-306 SHALL BE PROVIDED. 11B-602.3 OPERABLE PARTS: SHALL COMPLY WITH SECTION 11B-309. THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE MOUNTED AND LOCATED WITHIN 6 INCHES OF THE FRONT EDGE OF THE FOUNTAIN OR AUTOMATIC ELECTRONICALLY CONTROLLED DEVICE. 11B-602.4 SPOUT HEIGHT: SPOUT OUTLETS SHALL BE 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. 11B-602.5 SPOUT LOCATION: THE SPOUT SHALL BE LOCATED 15 INCHES MAXIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES MAXIMUM FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS. 11B-602.6 WATER FLOW: WATER FLOW SHALL COMPLY WITH SECTION 11B-602.6 11B-602.7 DRINKING FOUNTAINS FOR STANDING PERSONS: SPOUT OUTLETS OF THE DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND 43MAXIMUM ABOVE FINISH OR GROUND. 11B-602.8 DEPTH: WALL-AND POST-MOUNTED CANTILEVER DRINKING FOUNTAINS SHALL BE 18 INCHES MINIMUM AND 19 INCHES MAXIMUM IN DEPTH. 11B-602.9 PEDESTRIAN PROTECTION: ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED IN COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN WHICH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32 INCHES WIDE MINIMUM, AND 18 INCHES DEEP MINIMUM, AND SHALL COMPLY WITH SECTION 11B-305.7. WHEN USED, WING WALLS OR BARRIERS SHALL PROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6 INCHES VERTICALLY FROM THE FLOOR OR GROUND SURFACE. C BD A 17 " M A X . SEE PLAN 17 " M A X . 13-1/2" MIN. EQEQ 44 " M A X . H A N D O P E R A T E D FL U S H C O N T R O L S 18" MIN.18" MIN. > 2 4 " < 2 4 " ELEVATION PLANELEVATION PLAN (ALCOVE) 30"x48" CLEAR 36"x48" CLEAR T&H T&HNOT U S E D C B A 33 " -36 " T. O . G R A B B A R 48 " T. O . S H O W E R H E A D C O N T R O L H A N D L E 17 " M I N . 19 " M A X 30 " M I N . 60" MIN. 15" to 16" 6" MAX 24" MIN. 6" 24 " M I N . 21_ 2 " MAX. 11_2 " MA X . 27" MAX. 48 " M A X . T. O . S H O W E R C O N T R O L S ELEVATION ELEVATION PLAN STRUCTURAL STRENGTH: ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHERE A VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS (1112 N) IS APPLIED AT ANY POINT ON THE GRAB BAR, FASTENER MOUNTING DEVICE, OR SUPPORTING STRUCTURE. 36"x60" CLEAR RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt ACCESSIBILITY DETAILS G404 3/8" = 1'-0"1MOUNTING HEIGHTS 3/8" = 1'-0"2 MOUNTING HEIGHTS FOR RESTROOM ACCESSORIES 1/2" = 1'-0"3 ACCESSIBLE BENCH AND LOCKER DETAIL 1/2" = 1'-0"4 ACCESSIBLE TOILET PLAN & ELEVATIONS 1/2" = 1'-0"5 ACCESSIBLE SINK PLAN & SECTION 3" = 1'-0"6 STAIR LEVEL IDENTIFICATION SIGNS 3" = 1'-0"7 TACTILE SIGN REQUIREMENTS 1 1/2" = 1'-0"8ELEVATOR CONTROL PANEL 1 1/2" = 1'-0"9 MAXIMUM OCCUPANCY SIGN 3/8" = 1'-0"10EXIT & RESTROOM SIGNAGE 1/8" = 1'-0"11HI-LO DRINKING FOUNTAIN 1/2" = 1'-0"12 ACCESSIBLE URINAL PLAN & ELEVATIONS 1/2" = 1'-0"13 ACCESSIBLE SHOWER PLAN & ELEVATIONS N O T U S E D N O T U S E D N O T U S E D N O T U S E D N O T U S E D N O T U S E D N O T U S E D G. PROTECTION: PROTECT EXISTING AND NEW CONSTRUCTION FROM DAMAGE CAUSED BY CONSTRUCTION OPERATIONS; PROVIDE PROTECTIVE COVERING TO PROTECT SURFACES, AS APPROPRIATE. G.1. SALES AREA FLOORING, BOTH WOOD FLOORING AND TILE FLOORING, SHALL BE PROTECTED IN ITS ENTIRETY WITH MASONITE SHEETS. ALL JOINTS BETWEEN SHEETS SHALL BE FULLY TAPED TO PREVENT MOVEMENT AND/OR FOREIGN MATERIAL FROM GETTING UNDER MASONITE PROTECTION. G.2. GC SHALL START LAYOUT OF MASONITE SHEETS 6" AWAY FROM PERIMETER WALL STUDS, TYPICAL THROUGHOUT SALES AREA. H. CONSTRUCTION CLEANING: H.1. CONTROL ACCUMULATION OF WASTE MATERIALS AND RUBBISH. DISPOSE OF WASTE OFF-SITE AS APPROVED BY THE OWNER TO MAINTAIN A CLEAN SITE. H.2. MAINTAIN AREAS FREE OF DUST AND OTHER CONTAMINANTS DURING FINISHING OPERATIONS. H.3. MAINTAIN ALL OCCUPIED SPACES FREE OF DUST AND OTHER CONTAMINANTS PRIOR TO DAILY BUSINESS OPERATIONS. CLEANING SHALL INCLUDE VACUUMING, DUSTING, STAIN AND DIRT REMOVAL, AND CLEANING OF GLASS FURNITURE, AND OTHER SURFACES. SECTION 01430 CONSTRUCTION WASTE MANAGEMENT FOR SUSTAINABLE PRACTICE SECTION 01440 CONSTRUCTION INDOOR AIR QUALITY MANAGEMENT PLAN DIVISION 1: GENERAL REQUIREMENTS FOR SUSTAINABLE PRACTICES SECTION 01110 SUMMARY OF WORK SECTION 01330 SUBMITTAL PROCEDURES (AS REQUESTED IN DRAWINGS) SECTION 01352 SUSTAINABLE PRACTICE REQUIREMENTS SECTION 01450 QUALITY CONTROL SECTION 01500 TEMPORARY FACILITIES AND CONTROLS B.2.2. PRE-CONSUMER (POST-INDUSTRIAL) RECYCLED CONTENT COMES FROM PROCESS WASTE B.2.3. SCRAPS, SPILLS OR OTHER WASTE FROM THE ORIGINAL MANUFACTURING PROCESS THAT ARE COMBINED WITH OTHER CONSTITUENTS AFTER A MINIMAL AMOUNT OF REPROCESSING FOR USE IN THE FURTHER PRODUCTION OF THE SAME PRODUCT ARE NOT RECYCLED MATERIALS. B.3. REGIONAL MATERIALS: MATERIALS THAT ARE HARVESTED (EXTRACTED OR RECOVERED), PROCESSED AND MANUFACTURED WITHIN A RADIUS OF 500 MILES FROM THE PROJECT LOCATION B.4. COMPOSITE WOOD AND AGRI-FIBER BOARD: MANUFACTURED MATERIALS MADE FROM WOOD OR C. SUBMITTALS C.2. PROJECT MATERIALS COST DATA: PROVIDE THE NECESSARY COST DATA REQUESTED ON THE C.3. CONSTRUCTION WASTE MANAGEMENT - DIVERT 75% FROM LANDFILL C.3.1. COMPLY WITH DIVISION 1 SECTION 01430 "CONSTRUCTION WASTE MANAGEMENT" C.3.2. CONSTRUCTION WASTE MANAGEMENT PLAN. C.3.3. COMPLETE CONSTRUCTION WASTE CALCULATIONS TO INDICATE THAT AT LEAST 75% OF CONSTRUCTION, DEMOLITION, AND PACKAGING DEBRIS HAS BEEN RECYCLED AND/OR SALVAGED. C.3.4. ITEMIZED WASTE HAULING CERTIFICATES/RECEIPTS FOR ALL WASTE REMOVED FROM THE C.3.5. PROJECT SITE AND DOCUMENTATION OF RECYCLING RECOVERY RATE FOR OFF-SITE SORTING FACILITIES (IF WASTE IS COMMINGLED). C.4. RECYCLED CONTENT. CUT SHEET, PRODUCT LITERATURE OR LETTER FROM MANUFACTURER THAT C.5. PRODUCT DATA AND MATERIAL SAFETY DATA SHEETS (MSDS) FOR ALL PAINTS AND COATINGS C.6. LIST OF ALL INSTALLED PAINTS INCLUDING MANUFACTURER, QUANTITY USED IN GALLONS AND VOC CONTENT. C.7. LOW-EMITTING MATERIALS, FLOORING (CARPET): CUT SHEETS OF LETTER FROM MANUFACTURER CLEARLY INDICATING THAT ALL CARPET PRODUCTS MEET THE GREEN LABEL TEST PROGRAM REQUIREMENTS. C.8. LOW-EMITTING MATERIALS, COMPOSITE WOOD: CUT SHEETS CLEARLY INDICATING THE BONDING AGENTS USED FOR EACH COMPOSITE WOOD AND AGRI-FIBER PRODUCT AND ASSEMBLY USED IN THE PROJECT AND DEMONSTRATING THAT NO ADDED UREA-FORMALDEHYDE RESINS ARE USED IN THESE PRODUCTS D. PRODUCTS D.1. SUMMARY OF REFERENCE STANDARDS AND REQUIREMENTS FOR SUSTAINABLE PRACTICE, INDOOR ENVIRONMENTAL QUALITY - LOW EMITTING MATERIALS. D.2. ADHESIVES AND SEALANTS D.2.1. ADHESIVES, SEALANTS, AND SEALANT PRIMERS USED ON THE INTERIOR OF THE BUILDING SHALL COMPLY WITH THE VOC LIMITS OF THE SOUTH COAST RULE #1168 BY THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT, DATED JULY 1, 2005 (WWW.AQMD.GOV/RULES/REG/REG11/R1168.PDF) D.2.2. VOC LIMITS IN GRAMS PER LITER FOR ADHESIVES AND SEALANTS USED ON INTERIOR OF BUILDING ARE AS FOLLOWS: PRODUCT TYPE (LESS WATER) SEALANTS: ARCHITECTURAL POROUS ARCHITECTURAL SEALANT PRIMER NON-POROUS ARCHITECTURAL SEALANT PRIMER ARCHITECTURAL ADHESIVES APPLICATIONS INDOOR CARPET ADHESIVES CARPET PAD ADHESIVES OUTDOOR CARPET ADHESIVES WOOD FLOORING ADHESIVES RUBBER FLOOR ADHESIVES SUBFLOOR ADHESIVES CERAMIC TILE INSTALLATION VCT AND ASPHALT TILE ADHESIVES DRY WALL AND PANEL ADHESIVES COVE BASE INSTALLATION MULTIPURPOSE CONSTRUCTION ADHESIVE STRUCTURAL GLAZING ADHESIVES SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL PLASTIC FOAMS POROUS MATERIAL EXCEPT WOOD WOOD FIBERGLASS SPECIALTY APPLICATIONS PVC WELDING CPVC WELDING ABS WELDING PLASTIC CEMENT WELDING ADHESIVE PRIMER FOR PLASTIC CONTACT SPECIAL PURPOSE CONTACT ADHESIVES STRUCTURAL WOOD MEMBER ADHESIVE SHEET APPLIED RUBBER LINING OPERATIONS TOP AND TRIM ADHESIVE D.2.3. AEROSOL ADHESIVES SHALL COMPLY WITH THE GREEN SEAL STANDARD FOR COMMERCIAL ADHESIVES GS-36, AS NOTED BELOW: AEROSOL ADHESIVES GENERAL PURPOSE MIST SPRAY 65% VOCS BY WEIGHT GENERAL PURPOSE WEB SPRAY 55% VOCS BY WEIGHT SPECIAL PURPOSE AEROSOL ADHESIVES (ALL TYPES) 70% VOCS BY WEIGHT WATERPROOFING CONCRETE/MASONRY SEALERS 70% VOCS BY WEIGHT D.3. PAINTS AND COATINGS D.3.1. PAINTS APPLIED ON THE INTERIOR OF THE BUILDING SHALL COMPLY WITH GREEN SEAL PRODUCT SPECIFIC ENVIRONMENTAL REQUIREMENTS (WWW.GREENSEAL.ORG/CERTIFICATION/STANDARDS/PAINTS-GS11.PDF). D.3.1. ARCHITECTURAL PAINTS COATING AND PRIMERS APPLIED TO INTERIOR WALLS AS WELL AS ANTI-CORROSIVE PAINTS APPLIED TO INTERIOR FERROUS METAL SHALL NOT EXCEED THE VOC LIMITS AS PUT FORTH GREEN SEAL STANDARD GS-11 D.3.2. THE GREEN SEAL STANDARD IS INTENDED FOR PAINTS AND ANTI-CORROSIVE PAINTS. BOTH INTERIOR AND EXTERIOR PAINTS ARE ADDRESSED BY THE STANDARD, BUT ONLY LIMITS FOR INTERIOR PAINTS APPLY TO A LEED PROJECT. LIMITS ON VOCS IN GRAMS PER LITER FOR PAINTS AND ANTI-CORROSIVE PAINTS ARE AS FOLLOWS: VOC LIMIT (G/L) INTERIOR COATINGS FLAT EXTERIOR COATINGS FLAT ANTI-CORROSIVE SEMI-GLOSS FLAT D.3.3. CLEAR WOOD FINISHES, FLOOR COATINGS, STAIN, SEALERS AND SHELLACS APPLIED TO INTERIOR ELEMENTS SHALL COMPLY WITH THE VOC LIMITS SET FORTH IN THE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE 1113, ARCHITECTURAL COATINGS, DATED JANUARY, 2004 VOC LIMIT (G/L) CLEAR WOOD FINISH VARNISH LACQUER FLOOR SEALERS WATERPROOF SEALERS SANDING SEALERS ALL OTHER SEALERS STAINS SHELLACS CLEAR PIGMENTED D.4. CARPET D.4.1. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF THE CARPET AND RUG INSTITUTE'S GREEN LABEL PLUS PROGRAM. D.4.2. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF EQ CREDIT 4.1: VOC LIMIT OF 50 G/L. D.4.3. ALL OF THE RESILIENT FLOORING IN THE BUILDING INTERIOR MUST BE CERTIFIED AS COMPLIANT WITH THE FLOORSCORE STANDARD (CURRENT AS OF THE DATE OF THE LEED RATING SYSTEM, OR MORE STRINGENT VERSION) BY AN INDEPENDENT THIRD-PARTY. D.4.4. TILE SETTING ADHESIVES AND GROUT MUST MEET SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD) RULE #1168. VOC LIMITS ARE LISTED BELOW AND CORRESPOND TO AN EFFECTIVE DATE OF JULY 1, 2005 AND RULE AMENDMENT DATE OF JANUARY 7, 2005. CERAMIC TILE ADHESIVE: 65 G/L GROUT AND MORTAR: D.5. COMPOSITE WOOD D.5.1. ALL COMPOSITE WOOD AND AGRI-FIBER PRODUCTS INSTALLED INSIDE THE EXTERIOR MOISTURE BARRIER SHALL CONTAIN NO ADDED UREA-FORMALDEHYDE RESIN. A. GENERAL - AS REQUIRED FOR REMOVAL OF DEMOLITION AND OR NEW CONSTRUCTION DEBRIS B. RELATED DOCUMENTS B.1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND OTHER DIVISION 1 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. THIS SECTION DESCRIBES DEMOLITION AND CONSTRUCTION WASTE MANAGEMENT AND RECYCLING GOALS AND INCLUDES ADMINISTRATIVE AND PROCEDURAL REQUIREMENTS FOR THE DEVELOPMENT AND EXECUTION OF A CONSTRUCTION WASTE MANAGEMENT PLAN. RELATED SECTIONS INCLUDE THE FOLLOWING: B.1.1. DIVISION 1 SECTION "ENVIRONMENTAL PROCEDURES" FOR ADMINISTRATIVE PROCEDURES TO ACHIEVE ENVIRONMENTAL GOALS FOR THE WORK. B.1.2. DIVISION 1 SECTION "TEMPORARY FACILITIES AND CONTROLS" REQUIREMENTS FOR INSTALLATION, MAINTENANCE AND REMOVAL OF TEMPORARY UTILITIES, CONTROLS, AND FACILITIES DURING CONSTRUCTION. B.1.3. DIVISION 2 SECTION "SITE DEMOLITION" REQUIREMENTS FOR SALVAGE AND RECYCLING OF DEMOLITION DEBRIS. C. CONSTRUCTION WASTE MANAGEMENT GOALS C.1. THE OWNER HAS ESTABLISHED THAT THIS PROJECT SHALL GENERATE THE LEAST AMOUNT OF WASTE POSSIBLE AND THAT PROCESSES THAT ENSURE THE GENERATION OF AS LITTLE WASTE AS POSSIBLE DUE TO ERROR, POOR PLANNING, BREAKAGE, MISHANDLING, CONTAMINATION, OR OTHER FACTORS SHALL, BE EMPLOYED. C.2. OF THE INEVITABLE WASTE THAT IS GENERATED, AS MANY OF THE WASTE MATERIALS AS ECONOMICALLY FEASIBLE SHALL BE REUSED, SALVAGED, OR RECYCLED. WASTE DISPOSAL IN LANDFILLS SHALL BE MINIMIZED. C.3. DIVERSION GOAL: DIVERT 75% OF TOTAL PROJECT WASTE FROM THE LANDFILL (A MINIMUM 50% OF TOTAL PROJECT WASTE SHALL BE DIVERTED FROM THE LANDFILL) C.4. WITH REGARD TO THESE GOALS THE CONTRACTOR SHALL DEVELOP, FOR THE OWNER AND ARCHITECT'S REVIEW, A WASTE MANAGEMENT PLAN FOR THIS PROJECT. D. SUBMITTALS D.1. CONSTRUCTION WASTE MANAGEMENT PLAN D.2. PERIODIC AND FINAL SUMMARY REPORT OF WASTE MATERIALS RECYCLED, SALVAGED AND LANDFILL. D.3. WEIGHT TICKETS FOR ALL WASTE MATERIALS REMOVED FROM THE SITE DURING DEMOLITION AND CONSTRUCTION. E. CONSTRUCTION WASTE MANAGEMENT PLAN E.1. DRAFT WASTE MANAGEMENT PLAN: PRIOR TO THE PRE-CONSTRUCTION CONFERENCE, OR PRIOR TO ANY WASTE REMOVAL, WHICHEVER OCCURS SOONER, THE CONTRACTOR SHALL MEET WITH THE OWNER DESIGNATED REPRESENTATIVE(S) AND ARCHITECT TO DISCUSS PREPARATION OF A DRAFT WASTE MANAGEMENT PLAN. THE DRAFT PLAN SHALL CONTAIN THE FOLLOWING: E.1.1. ANALYSIS OF THE PROPOSED JOBSITE WASTE TO BE GENERATED. INCLUDE THE TYPES OF MATERIAL TO BE GENERATED AND ESTIMATED QUANTITY OF EACH MATERIAL (IN TONS). E.1.2. LANDFILL OPTIONS: ESTIMATED COST OF DISPOSING OF ALL PROJECT WASTE IN TRANSFER STATION(S)/LANDFILL(S), NAME OF TRANSFER STATION(S)/LANDFILL(S) WHERE PROJECT WASTE WOULD NORMALLY BE DISPOSED OF AND TIPPING FEES. ESTIMATED COST OF TRANSPORTATION AND OTHER RELEVANT COSTS AND FEES. E.1.3. ALTERNATIVES TO LANDFILL: A LIST OF EACH MATERIAL PROPOSED TO BE SALVAGED OR RECYCLED DURING THE COURSE OF THE PROJECT. THE LIST OF THESE MATERIALS IS TO INCLUDE, AT A MINIMUM, THE FOLLOWING MATERIALS: E.1.4. MATERIAL HANDLING PROCEDURES: A DESCRIPTION OF THE MEANS BY WHICH ANY WASTE MATERIALS IDENTIFIED IN ITEM (3) ABOVE WILL BE PROTECTED FROM CONTAMINATION, AND A DESCRIPTION OF THE MEANS TO BE EMPLOYED IN RECYCLING THE ABOVE MATERIALS CONSISTENT WITH REQUIREMENTS FOR ACCEPTANCE BY DESIGNATED FACILITIES. E.1.5. TRANSPORTATION: A DESCRIPTION OF THE MEANS OF TRANSPORTATION OF THE RECYCLABLE MATERIALS (WHETHER MATERIALS WILL BE SITE-SEPARATED AND SELF-HAULED TO DESIGNATED CENTERS, OR WHETHER MIXED MATERIALS WILL BE COLLECTED BY A WASTE HAULER AND REMOVED FROM THE SITE) AND DESTINATION OF MATERIALS. THE FINAL DESTINATION MUST BE APPROVED BY OWNER DESIGNATED REPRESENTATIVE(S). E.1.6. SOURCE REDUCTION: LIST PROCESSES THAT MINIMIZE WASTE SUCH AS WORKING WITH SUPPLIERS TO TAKE BACK OR BUY BACK SUBSTANDARD, REJECTED OR UNUSED ITEMS AND TO DELIVER SUPPLIES USING RETURNABLE PALLETS AND CONTAINERS. ALSO INCLUDE PROCEDURES TO MINIMIZE BREAKAGE, MISHANDLING, CONTAMINATION, AND OTHER FACTORS THAT REDUCE JOB SITE WASTE. E.1.7. MEETINGS: A DESCRIPTION OF THE REGULAR MEETINGS TO BE HELD TO ADDRESS WASTE MANAGEMENT. CONTRACTOR SHALL CONDUCT CONSTRUCTION WASTE MANAGEMENT MEETINGS. MEETINGS SHALL INCLUDE SUBCONTRACTORS AFFECTED BY THE WASTE MANAGEMENT PLAN AS WELL AS OWNER DESIGNATED REPRESENTATIVE(S). AT A MINIMUM, WASTE MANAGEMENT GOALS AND ISSUES SHALL BE DISCUSSED AT THE FOLLOWING MEETINGS: PRE-BID MEETING, PRE-CONSTRUCTION MEETING, AND REGULARLY SCHEDULED JOB-SITE MEETINGS. E.1.8. INDICATE ANY INSTANCE WHERE COMPLIANCE WITH REQUIREMENTS OF THIS SPECIFICATION DOES NOT APPEAR TO BE POSSIBLE AND REQUEST RESOLUTION FROM THE OWNER AND ARCHITECT. E.2. RESOURCE FOR DEVELOPMENT AND IMPLEMENTATION OF WASTE MANAGEMENT PLAN: THE FOLLOWING RESOURCE CAN BE USED IN DEVELOPING AND IMPLEMENTING THE DRAFT WASTE MANAGEMENT PLAN. E.3. WASTE MANAGEMENT PLAN REVIEW MEETING: ONCE THE OWNER AND ARCHITECT HAVE REVIEWED THE DRAFT WASTE MANAGEMENT PLAN AND PRIOR TO ANY WASTE REMOVAL AT THE SITE, SCHEDULE AND CONDUCT A FOLLOW-UP MEETING AGREED UPON DURING THE MEETING IDENTIFIED IN ITEM 2.4A. THE PURPOSE OF THE MEETING IS TO REVIEW THE DRAFT WASTE MANAGEMENT PLAN AND DISCUSS PROCEDURES, SCHEDULES AND SPECIFIC REQUIREMENTS FOR WASTE MATERIALS RECYCLING AND DISPOSAL. DISCUSS COORDINATION AND INTERFACE BETWEEN THE CONTRACTOR AND OTHER CONSTRUCTION ACTIVITIES. IDENTIFY AND RESOLVE POTENTIAL COMPLIANCE PROBLEMS WITH REQUIREMENTS. RECORD MINUTES OF THE MEETING, IDENTIFYING ALL CONCLUSIONS REACHED AND MATTERS REQUIRING FURTHER RESOLUTION. E.3.1. ATTENDEES: THE CONTRACTOR AND RELATED CONTRACTOR PERSONNEL ASSOCIATED WITH THE WORK OF THIS SECTION, INCLUDING PERSONNEL TO BE IN CHARGE OF THE WASTE MANAGEMENT PROGRAM, ARCHITECT, OWNER AND SUCH ADDITIONAL PERSONNEL AS THE ARCHITECT OR OWNER DEEM APPROPRIATE. E.4. FINAL CONSTRUCTION WASTE MANAGEMENT PLAN: MAKE ANY REVISIONS TO THE DRAFT WASTE MANAGEMENT PLAN AGREED UPON DURING THE MEETING IDENTIFIED IN ITEM 2.4A ABOVE AND INCORPORATE RESOLUTIONS AGREED TO BE MADE SUBSEQUENT TO THE MEETING. SUBMIT THE REVISED PLAN TO THE OWNER AND ARCHITECT FOR APPROVAL WITHIN 10 CALENDAR DAYS OF THE MEETING. PART 4 - EXECUTION F. IMPLEMENTATION OF CONSTRUCTION WASTE MANAGEMENT PLAN F.1. MANAGER: THE CONTRACTOR SHALL DESIGNATE AN ON-SITE PARTY (OR PARTIES) RESPONSIBLE FOR INSTRUCTING WORKERS AND OVERSEEING AND DOCUMENTING RESULTS OF THE WASTE MANAGEMENT PLAN FOR THE PROJECT. F.2. DISTRIBUTION: THE CONTRACTOR SHALL DISTRIBUTE COPIES OF THE WASTE MANAGEMENT PLAN TO THE JOB SITE FOREMAN, EACH SUBCONTRACTOR, THE OWNER, AND THE ARCHITECT. F.3. INSTRUCTION: THE CONTRACTOR SHALL PROVIDE ON-SITE INSTRUCTION OF APPROPRIATE SEPARATION, HANDLING, AND RECYCLING, SALVAGE, REUSE, AND RETURN METHODS TO BE USED BY ALL PARTIES AT THE APPROPRIATE STAGES OF THE PROJECT. F.4. SEPARATION FACILITIES: THE CONTRACTOR SHALL LAY OUT AND LABEL A SPECIFIC AREA TO FACILITATE SEPARATION OF MATERIALS DURING CONSTRUCTION FOR POTENTIAL RECYCLING, SALVAGE, REUSE, AND RETURN. RECYCLING AND WASTE BIN AREAS ARE TO BE KEPT NEAT AND CLEAN AND CLEARLY MARKED IN ORDER TO AVOID CONTAMINATION OF MATERIALS. F.5. HAZARDOUS WASTE: HAZARDOUS WASTES SHALL BE SEPARATED, STORED, AND DISPOSED OF ACCORDING TO LOCAL REGULATIONS. F.6. APPLICATION FOR PROGRESS PAYMENTS: THE CONTRACTOR SHALL SUBMIT WITH EACH APPLICATION FOR PROGRESS PAYMENT A SUMMARY OF WASTE GENERATED BY THE PROJECT. FAILURE TO SUBMIT THIS INFORMATION SHALL RENDER THE APPLICATION FOR PAYMENT INCOMPLETE AND SHALL DELAY PROGRESS PAYMENT. THE SUMMARY SHALL BE SUBMITTED ON A FORM ACCEPTABLE TO THE OWNER AND SHALL CONTAIN THE FOLLOWING INFORMATION: F.6.1. THE AMOUNT OF WASTE (IN TONS) LANDFILLED FROM THE PROJECT, THE IDENTITY OF THE TRANSFER STATION/LANDFILL, THE TOTAL AMOUNT OF TIPPING FEES PAID AT THE LANDFILL, THE TRANSPORTATION COST, AND THE TOTAL DISPOSAL COST. INCLUDE MANIFESTS, WEIGHT, TICKETS RECEIPTS, AND INVOICES F.6.2. FOR EACH MATERIAL RECYCLED, REUSED, OR SALVAGED FROM THE PROJECT, THE AMOUNT (IN TONS), THE DATE REMOVED FROM THE JOBSITE, THE RECEIVING PARTY, THE TRANSPORTATION COST, THE AMOUNT OF ANY MONEY PAID OR RECEIVED FOR THE RECYCLED OR SALVAGED MATERIAL, AND THE NET TOTAL COST OR SAVINGS. F.7. AT THE END OF THE PROJECT THE CONTRACTOR SHALL SUBMIT A FINAL WASTE MANAGEMENT REPORT. THE REPORT SHALL BE SUBMITTED ON A FORM ACCEPTABLE TO THE OWNER AND SHALL CONTAIN THE FOLLOWING INFORMATION: F.7.1. THE TOTAL AMOUNT OF WASTE LANDFILLED FROM THE PROJECT, THE IDENTITY OF THE TRANSFER STATION/LANDFILL, THE TOTAL AMOUNT OF TIPPING FEES PAID AT THE LANDFILL, THE TRANSPORTATION COST, AND THE TOTAL DISPOSAL COST. F.7.2. THE TOTAL AMOUNT (IN TONS) OF EACH MATERIAL RECYCLED, REUSED, OR SALVAGED FROM THE PROJECT, THE RECEIVING PARTY, AND NET COST SAVINGS OR ADDITIONAL COSTS RESULTING FROM SEPARATING AND RECYCLING (VERSUS LANDFILLING) EACH MATERIAL. THE TOTAL AMOUNT OF ALL MATERIALS RECYCLED IN TONS AND THE TOTAL NET COST SAVINGS OR ADDITIONAL COSTS. F.7.3. THE TOTAL PERCENTAGE OF MATERIAL RECYCLED IN TONS A. RELATED DOCUMENTS B. SUMMARY B.1. THIS SECTION DESCRIBES CONSTRUCTION INDOOR AIR QUALITY (IAQ) GOALS AND INCLUDES ADMINISTRATIVE AND PROCEDURAL REQUIREMENTS FOR THE DEVELOPMENT AND EXECUTION OF A CONSTRUCTION AIR QUALITY MANAGEMENT PLAN. B.2. RELATED SECTIONS INCLUDE THE FOLLOWING: B.2.1. DIVISION 1 SECTION "SUBMITTAL PROCEDURES" FOR REQUIRED SUBMITTAL PROCEDURES. B.2.2. DIVISION 1 SECTION "TEMPORARY FACILITIES AND CONTROLS" REQUIREMENTS FOR INSTALLATION, MAINTENANCE AND REMOVAL OF TEMPORARY CONTROLS, AND FACILITIES DURING CONSTRUCTION.UTILITIES, B.2.3. DIVISION 1 SECTION "PRODUCT REQUIREMENTS" PROCEDURES FOR STORAGE OF INTERIOR MATERIALS TO PREVENT EXPOSURE TO MOISTURE AND POLLUTANTS. B.2.4. DIVISION 15 - MECHANICAL (SEE MECHANICAL SHEETS) C. INDOOR AIR QUALITY MANAGEMENT SUMMARY C.1. THE OWNER HAS ESTABLISHED THAT THE CONTRACTOR SHALL PREVENT INDOOR AIR QUALITY PROBLEMS RESULTING FROM THE CONSTRUCTION PROCESS, TO SUSTAIN THE COMFORT AND WELL-BEING OF CONSTRUCTION WORKERS AND BUILDING OCCUPANTS C.2. PROTECT THE VENTILATION SYSTEM COMPONENTS DURING CONSTRUCTION AND CLEAN CONTAMINATED COMPONENTS AFTER CONSTRUCTION IS COMPLETE. C.3. CONTROL SOURCES OF POTENTIAL IAQ POLLUTANTS BY CONTROLLING SELECTION OF MATERIALS AND PROCESSES USED IN PROJECT CONSTRUCTION. D. SUBMITTALS D.1. IAQ MANAGEMENT PLAN FOR THE CONSTRUCTION AND PRE-OCCUPANCY PHASES OF THE PROJECT. D.2. CUT SHEETS OF FILTRATION MEDIA USED DURING CONSTRUCTION WITH MERV VALUES HIGHLIGHTED. E. CONSTRUCTION AIR QUALITY MANAGEMENT PLAN E.1. DEVELOP A DRAFT INDOOR AIR QUALITY (IAQ) MANAGEMENT PLAN FOR THE CONSTRUCTION AND PRE-OCCUPANCY PHASES OF THE BUILDING AS FOLLOWS: E.1.1. DURING CONSTRUCTION MEET OR EXCEED THE MINIMUM REQUIREMENTS OF THE SHEET METAL AND AIR CONDITIONING NATIONAL CONTRACTORS ASSOCIATION (SMACNA) IAQ GUIDELINES FOR OCCUPIED BUILDINGS UNDER CONSTRUCTION 1995, CHAPTER 3 E.1.2. PROTECT STORED ON-SITE OR INSTALLED ABSORPTIVE MATERIALS FROM MOISTURE DAMAGE. E.2. THE SMACNA IAQ GUIDELINES FOR OCCUPIED BUILDINGS UNDER CONSTRUCTION PROVIDES AN OVERVIEW OF AIR POLLUTION ASSOCIATED WITH CONSTRUCTION, CONTROL MEASURES, CONSTRUCTION PROCESS MANAGEMENT, QUALITY CONTROL, COMMUNICATING WITH OCCUPANTS, AND CASE STUDIES. THESE GUIDELINES CAN BE ACCESSED AT WWW.SMACNA.ORG. CHAPTER 3 OF THE SMACNA GUIDELINES RECOMMENDS CONTROL MEASURES IN FIVE AREAS: HVAC PROTECTION, SOURCE CONTROL, PATHWAY INTERRUPTION, HOUSEKEEPING, AND SCHEDULING. REVIEW THE APPLICABILITY OF EACH CONTROL MEASURE AND INCLUDE THOSE THAT APPLY IN THE DRAFT IAQ MANAGEMENT PLAN. E.2.1. HVAC PROTECTION: SHUT DOWN THE RETURN SIDE OF THE HVAC SYSTEM WHENEVER POSSIBLE DURING HEAVY CONSTRUCTION. IF THE SYSTEM MUST REMAIN OPERATIONAL DURING CONSTRUCTION INCLUDE THE FOLLOWING STRATEGIES THAT APPLY: E.2.1.1. FIT THE RETURN SIDE OF THE HVAC SYSTEM WITH TEMPORARY FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8. E.2.1.2. SOLATE THE RETURN SIDE OF THE HVAC SYSTEM FROM THE SURROUNDING ENVIRONMENT AS MUCH AS POSSIBLE (E.G., PLACE ALL TILES FOR THE CEILING PLENUM, REPAIR ALL DUCTS AND AIR HANDLER LEAKS). E.2.1.3. DAMPER OFF THE RETURN SYSTEM IN THE HEAVIEST WORK AREAS AND SEAL THE RETURN SYSTEM OPENINGS WITH PLASTIC. E.2.1.4. UPGRADE THE FILTER EFFICIENCY WHERE MAJOR LOADING IS EXPECTED TO AFFECT OPERATING HVAC SYSTEM. E.2.1.5. CLEAN PERMANENT RETURN AIR DUCTWORK PER NATIONAL AIR DUCT CLEANING ASSOCIATION STANDARDS UPON COMPLETION OF ALL CONSTRUCTION AND FINISH INSTALLATION WORK. E.2.1.6. REPLACE ALL FILTRATION MEDIA PRIOR TO OCCUPANCY. E.2.2. SOURCE CONTROL: PROPOSE THE SUBSTITUTION OF NON-TOXIC FORMULATIONS OF MATERIALS THAT ARE GENERALLY THE RESPONSIBILITY OF THE CONTRACTOR SUCH AS CAULKS, SEALANTS, AND CLEANING PRODUCTS. E.2.3. PATHWAY INTERRUPTION: PREVENT CONTAMINATION OF CLEAN SPACES. INCLUDE THE FOLLOWING STRATEGIES THAT APPLY: E.2.3.1. USE 100% OUTSIDE AIR VENTILATION (WHEN OUTSIDE TEMPERATURES ARE BETWEEN 55 DEGREES F AND 85 DEGREES F AND HUMIDITY IS BETWEEN 30% AND 60%) WITH AIR EXHAUSTED DIRECTLY TO THE OUTSIDE DURING INSTALLATION OF FINISHES AND OTHER VOC EMITTING MATERIALS. E.2.3.2. ERECT SOME TYPE OF BARRIER BETWEEN WORK AREAS OR BETWEEN THE INSIDE AND OUTSIDE OF THE BUILDING TO PREVENT UNWANTED AIRFLOW FROM DIRTY TO CLEAN AREAS. E.2.4. HOUSEKEEPING: REDUCE CONSTRUCTION CONTAMINATION IN THE BUILDING PRIOR TO OCCUPANCY THROUGH HVAC AND REGULAR SPACE CLEANING ACTIVITIES. E.2.4.1. STORE BUILDING MATERIALS IN A WEATHER TIGHT, CLEAN AREA PRIOR TO UNPACKING FOR INSTALLATION. E.2.4.2. CHECK FOR POSSIBLE DAMAGE TO BUILDING MATERIALS FROM HIGH HUMIDITY. E.2.4.3. CLEAN ALL COILS, AIR FILTERS, AND FANS BEFORE TESTING AND BALANCING PROCEDURES ARE PERFORMED. E.2.5. SCHEDULING: SPECIFY CONSTRUCTION SEQUENCING TO REDUCE ABSORPTION OF VOC'S BY MATERIALS THAT ACT AS SINKS OR CONTAMINANT SOURCES. COMPLETE APPLICATION OF WET AND ODOR-EMITTING MATERIALS SUCH AS PAINTS, SEALANTS, AND COATINGS BEFORE INSTALLING SINK MATERIALS SUCH AS CEILING TILES, CARPETS, INSULATION, GYPSUM PRODUCTS, AND FABRIC-COVERED FURNISHINGS ARE INSTALLED. E.2.5.1. PROTECT STORED ON-SITE OR INSTALLED ABSORPTIVE MATERIALS FROM EXPOSURE TO MOISTURE THROUGH PRECIPITATION, PLUMBING LEAKS, OR CONDENSATION FROM THE HVAC SYSTEM TO PREVENT MICROBIAL CONTAMINATION. E.2.5.2. DRAFT IAQ MANAGEMENT PLAN REVIEW MEETING: ONCE THE OWNER AND ARCHITECT HAVE REVIEWED THE DRAFT IAQ MANAGEMENT PLAN AND PRIOR TO CONSTRUCTION AT THE SITE, SCHEDULE AND CONDUCT A MEETING TO REVIEW THE DRAFT IAQ MANAGEMENT PLAN AND DISCUSS PROCEDURES, SCHEDULES AND SPECIFIC REQUIREMENTS FOR IAQ DURING THE CONSTRUCTION AND PRE-CONSTRUCTION PHASES OF THE BUILDING. DISCUSS COORDINATION AND INTERFACE BETWEEN THE CONTRACTOR AND OTHER CONSTRUCTION ACTIVITIES. IDENTIFY AND RESOLVE PROBLEMS WITH COMPLIANCE TO THE REQUIREMENTS. RECORD MINUTES OF THE MEETING, IDENTIFY ALL CONCLUSIONS REACHED AND MATTERS REQUIRING FURTHER RESOLUTION. PRODUCTS A. PRODUCTS AS REQUIRED TO ACHIEVE GOALS STATED IN IAQ MANAGEMENT PLAN PART 3 EXECUTION A. IMPLEMENTATION OF INDOOR AIR QUALITY MANAGEMENT PLAN END OF SECTION 01440 THAT ONE INDUSTRY HAS SOLD OR TRADED WITH ANOTHER THROUGH THE MARKETPLACE. THIS DEFINITION DOES NOT INCLUDE IN-HOUSE TRIMMINGS, WHICH ARE NORMALLY FED BACK INTO THE SAME MANUFACTURING PROCESS. POST-CONSUMER RECYCLED CONTENT COMES FROM CONSUMER WASTE, MUCH OF WHICH COMES FROM RESIDENTIAL CURBSIDE RECYCLING PROGRAMS FOR ALUMINUM, GLASS, PLASTIC AND PAPER. TO BE A FEEDSTOCK THE RAW MATERIALS NEED TO HAVE SERVED A USEFUL PURPOSE OR CONTENT BEFORE BEING USED AGAIN AGRICULTURAL FIBERS MANUFACTURED WITH BONDING AGENTS. COMPOSITE WOOD MATERIALS INCLUDE PARTICLE BOARD, MEDIUM DENSITY FIBERBOARD (MDF), PLYWOOD, STRAWBOARD, WHEATBOARD, PANEL SUBSTRATES AND DOOR CORES. C.1. GENERAL: IT IS THE INTENT OF THESE SPECIFICATIONS TO OUTLINE THE REQUIRED DOCUMENTATION FOR A SUSTAINABLE DESIGN USING LEED AS GUIDELINES. GENERAL CONTRACTOR SHALL DOCUMENT THESE GUIDELINES AS NOTED AND SHALL BE PREPARED TO PROVIDE DOCUMENTATION WHEN REQUESTED BY OWNER AND /OR REPRESENTATIVES. SUBMITTAL TO LEED FOR CERTIFICATION IS NOT REQUIRED LEED MATERIALS CALCULATOR (SAMPLE PROVIDED), INCLUDING THE TOTAL PROJECT MATERIALS COST AND ITEMIZED COSTS OF SPECIFIC MATERIALS BEING TRACKED FOR LEED CREDITS. ALL MATERIAL COSTS EXCLUDE LABOR AND EQUIPMENT AND THE TOTAL MATERIALS COST IS EXCLUSIVE OF SPECIALTIES, CONVEYING SYSTEMS AND MECHANICAL AND ELECTRICAL COMPONENTS. CLEARLY INDICATES THE PERCENTAGE BY WEIGHT OF POST-CONSUMER AND PRE-CONSUMER (POST-INDUSTRIAL) RECYCLED CONTENT. MATERIAL COST. REGIONAL MATERIALS SHALL BE USED WHEN POSSIBLE AND AS APPLICABLE. CUT SHEET, PRODUCT LITERATURE OR LETTER FROM MANUFACTURER INDICATING THE LOCATION OF HARVEST, PROCESSING AND MANUFACTURER. USED INSIDE THE BUILDING'S MOISTURE BARRIER INDICATING THE VOC CONTENT OF EACH PRODUCT AND VERIFYING THAT EACH PRODUCT MEETS THE REQUIREMENTS 250 775 250 50 50 50 100 60 50 65 50 50 50 70 100 30 50 50 80 510 490 325 350 550 80 250 140 850 250 150 50 200 100 250 250 250 350 550 100 250 275 200 250 730 250 A. CONCRETE B. ASPHALT C. BRICKS D. CONCRETE MASONRY UNITS (CMU) E. LAND CLEARING DEBRIS F. CLEAN DIMENSION WOOD G. PLYWOOD, OSB, AND PARTICLE BD H. CARDBOARD I. PAPER NON-FLAT GLOSS NON-FLAT VOC LIMIT G/L A.1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND OTHER DIVISION 1 SPECIFICATION SECTIONS, APPLY TO THIS SECTION. A. DEFINITIONS A.1. OWNER: LEASING TENANT OF SPACE BEING IMPROVED UNDER THIS CONTRACT OR THEIR CONSTRUCTION MANAGER. A.2. BUILDING MANAGER: BUILDING LANDLORD. A.3. OWNER / REPRESENTATIVE: A FIRM RETAINED BY THE OWNER TO ADMINISTER THE CONTRACT FOR CONSTRUCTION, INCLUDING PROCESSING OF SUBMITTALS, PAY APPLICATIONS, PUNCH LISTS, AND OTHER CONSTRUCTION ADMINISTRATION DUTIES. A.4. CONSTRUCTION MANAGER: "OWNER REPRESENTATIVE" DURING CONSTRUCTION B. SPECIAL WORK REQUIREMENTS: B.1. OBTAIN A COPY OF, AND COMPLY WITH, ALL DESIGN & CONSTRUCTION REQUIREMENTS OF THE BUILDING LANDLORD. NOTIFY THE OWNER/ REPRESENTATIVE IMMEDIATELY IN THE EVENT THAT LANDLORD'S REQUIREMENTS CONFLICT WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS. B.2. LIMIT USE OF PREMISES TO ONLY THOSE AREAS INVOLVED IN THE CONSTRUCTION OPERATIONS AND AS REQUIRED FOR ACCESS. B.3. COORDINATE USE OF PREMISES UNDER DIRECTION OF THE OWNER, AND IN ACCORDANCE WITH THE REQUIREMENTS OF JURISDICTIONAL CODE AUTHORITIES. B.4. OWNER OCCUPANCY REQUIREMENTS: OWNER RETAINS THE RIGHT TO OCCUPY THE EXISTING ADJACENT PORTIONS OF THE PREMISES DURING ENTIRE PERIOD OF CONSTRUCTION. COOPERATE WITH THE OWNER TO MINIMIZE CONFLICT, AND FACILITATE OWNER'S OPERATIONS. B.5. PERFORM WORK IN OWNER OCCUPIED AREAS ONLY WHILE THE FACILITY IS CLOSED, UNLESS APPROVED OTHERWISE. C. SEPARATE WORK: C.1. CERTAIN ITEMS WILL BE FURNISHED AND INSTALLED BY OTHERS. REFER TO THE RESPONSIBILITY MATRIX ON THE DRAWINGS. C.2. PERFORM WORK SO AS TO ALLOW THE PERFORMANCE OF WORK BY OTHER CONTRACTORS. D. ITEMS FURNISHED BY OWNER FOR INSTALLATION BY THE CONTRACTOR: D.1. CERTAIN ITEMS WILL BE FURNISHED FOR INSTALLATION BY THE CONTRACTOR. REFER TO THE RESPONSIBILITY MATRIX ON THE DRAWINGS. COORDINATE WORK TO FACILITATE INSTALLATION OF THESE ITEMS. D.2. OWNER RESPONSIBILITIES: D.2.1. ARRANGE FOR AND DELIVER SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES TO CONTRACTOR AS APPROPRIATE. D.2.2. ARRANGE AND PAY FOR PRODUCT DELIVERY TO SITE. D.2.3. UPON DELIVERY, INSPECT PRODUCTS JOINTLY WITH CONTRACTOR. D.2.4. SUBMIT CLAIMS FOR TRANSPORTATION DAMAGE. D.2.5. ARRANGE FOR REPLACEMENT OF DAMAGED, DEFECTIVE, OR MISSING ITEMS. D.2.6. ARRANGE FOR MANUFACTURERS' WARRANTIES, INSPECTIONS, AND SERVICE. D.3. CONTRACTOR'S RESPONSIBILITIES: D.3.1. REVIEW SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES WHEN FURNISHED. D.3.2. RECEIVE AND UNLOAD PRODUCTS AT SITE; INSPECT FOR COMPLETENESS, FOR DAMAGE, JOINTLY WITH OWNER. D.3.3. HANDLE, STORE, PROTECT, INSTALL AND FINISH PRODUCTS. D.3.4. REPAIR OR REPLACE ITEMS DAMAGED BY WORK OF THIS CONTRACT. D.3.5. COORDINATION: D.3.5.1. COORDINATE WORK OF ALL TRADES TO ASSURE EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF CONSTRUCTION ELEMENTS, WITH PROVISIONS FOR ACCOMMODATING ITEMS INSTALLED LATER. D.3.5.2. COORDINATE SPACE REQUIREMENTS FOR SPRINKLER, MECHANICAL & ELECTRICAL SYSTEMS. MAKE RUNS PARALLEL WITH LINES OF BUILDING. UTILIZE SPACES EFFICIENTLY, AND MAXIMIZE ACCESSIBILITY FOR MAINTENANCE, REPAIR, AND OTHER INSTALLATIONS. D.3.5.3. COORDINATE WORK OF ALL DESIGN/BUILD SUBCONTRACTORS WITH OTHER WORK INDICATED ON THE DRAWINGS. D.3.6. EXISTING UTILITIES: D.3.6.1. THE ARCHITECT OR THE OWNER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF EXISTING UTILITY LINE INFORMATION. UTILITY INFORMATION SHALL BE VERIFIED BY THE CONTRACTOR. D.3.6.2. UNLESS OTHERWISE REQUIRED, MAINTAIN ALL EXISTING UTILITIES UNDISTURBED DURING PROGRESS OF WORK. D.3.6.3. WHERE TEMPORARY UTILITY SHUTDOWN IS REQUIRED FOR THE PERFORMANCE OF THE WORK, SCHEDULE AND COORDINATE WITH THE OWNER/BUILDING MANAGER. SHOULD THE CONTRACTOR IN THE PERFORMANCE OF THE WORK, DISTURB, DISCONNECT OR DAMAGE ANY EXISTING ANY EXISTING UTILITIES REQUIRED TO REMAIN IN SERVICE, ALL EXPENSE ARISING FROM SUCH DISTURBANCE, REPLACING OR REPAIR THEREOF SHALL BE BORNE BY THE CONTRACTOR. D.3.6.4. MAINTAIN AND OPERATE UTILITIES SYSTEMS TO ASSURE CONTINUOUS SERVICE, EXCEPT AS OTHERWISE APPROVED BY THE OWNER/BUILDING MANAGER. GIVE NOT LESS THAN 7 DAYS NOTICE OF PROPOSED UTILITY SHUTDOWNS. D.3.6.5. OBTAIN APPROVAL FROM THE OWNER/BUILDING MANAGER PRIOR TO CUTTING ANY UTILITY LINES. A. A. SUBMITTAL PROCEDURE: A.1. NO SUBSTITUTIONS NOR DEVIATIONS FROM SPECIFIED PRODUCTS WILL BE ACCEPTED. LEAVE SPACE FOR CONTRACTOR AND OWNER / REPRESENTATIVE REVIEW STAMPS. A.2. REVIEW AND SIGN EACH SUBMITTAL PRIOR TO SUBMITTAL TO THE OWNER / REPRESENTATIVE. UNSIGNED SUBMITTALS WILL BE RETURNED UN-REVEALED. A.3. UNLESS SPECIFIED OTHERWISE, SUBMIT THE NUMBER OF SUBMITTALS THE CONTRACT REQUIRES. A.4. TRANSMIT EACH ITEM TO THE OWNER / REPRESENTATIVE UNDER AIA FORM G810, UNLESS APPROVED OTHERWISE. INCLUDE PROJECT NAME, CONTRACTOR NAME, SUBCONTRACTOR OR SUPPLIER NAME, AND DRAWING SHEET, DETAIL NUMBER, OR SPECIFICATION SECTION NUMBER CORRESPONDING TO THE SUBMITTAL AS APPROPRIATE. A.5. TRANSMIT IDENTICAL COPY, IN SAME QUANTITY, TO OWNER'S CONSTRUCTION MANAGER SIMULTANEOUSLY. A.6. MAKE SUBMITTALS AS REQUESTED IN THE DRAWINGS TO CAUSE NO DELAY IN THE WORK. ALLOW SUFFICIENT TIME FOR POSSIBLE REVISION AND RESUBMITTAL OF REJECTED SUBMITTALS. COORDINATE SUBMITTAL OF RELATED ITEMS. REVISE AND RESUBMIT REJECTED SUBMITTALS AS REQUIRED TO OBTAIN APPROVAL, IDENTIFYING CHANGES MADE SINCE PREVIOUS SUBMITTAL. B. SHOP DRAWINGS, DESIGN-BUILD DRAWINGS, PRODUCT DATA AND SAMPLES: B.1. SHOP DRAWINGS B.1.1. NUMBER OF COPIES: UNLESS OTHERWISE SPECIFIED, SUBMIT TO THE OWNER / REPRESENTATIVE ONE LEGIBLE RIGHT-READING REPRODUCIBLE AND ONE COPY FOR REVIEW, EXCEPT THAT SHOP DRAWINGS 11"X17" OR SMALLER MAY BE SUBMITTED IN THE FORM OF TWO BLACKLINE OR ELECTROSTATIC BOND COPIES. B.1.2. UNLESS SPECIFIED OTHERWISE, DRAWINGS SHALL SHOW QUANTITIES, MATERIALS, METHODS OF ASSEMBLY, ADJACENT CONSTRUCTION, DIMENSIONS, AND ALL OTHER APPROPRIATE INFORMATION TO FULLY ILLUSTRATE THE WORK. B.1.3. G.C. TO SUBMIT SPRINKLER SHOP DWGS AND FIRE ALARM SHOP DRAWINGS TO CONSTRUCTION PROJECT MANAGER FOR REVIEW. B.2. PRODUCT DATA: B.2.1. MARK EACH COPY TO IDENTIFY APPLICABLE PRODUCTS, MODELS, OPTIONS AND OTHER DATA; SUPPLEMENT MANUFACTURE'S STANDARD DATA TO PROVIDE INFORMATION UNIQUE TO THE WORK. B.2.2. SUBMIT THE NUMBER OF COPIES THAT THE OWNER / REPRESENTATIVE REQUIRES. B.3. SAMPLES: B.4. SUBMIT SAMPLES AS SPECIFIED IN THE TECHNICAL SECTIONS. B.5. INCLUDE IDENTIFICATION ON EACH SAMPLE GIVING FULL INFORMATION. B.6. SUBMIT THREE SAMPLES, ONE OF WHICH WILL BE RETAINED BY THE OWNER / REPRESENTATIVE, UNLESS INDICATED OTHERWISE IN THE TECHNICAL SECTION. C. CERTIFICATES: SUBMIT THE ORIGINAL SIGNED VERSION TO THE OWNER / REPRESENTATIVE. A. SUMMARY A.1. THIS SECTION INCLUDES GENERAL REQUIREMENTS AND PROCEDURES FOR SUSTAINABLE DESIGN GUIDELINES B. RELATED SECTIONS B.1. RELATED SECTIONS INCLUDE THE FOLLOWING: B.1.1. SECTION 01440 - CONSTRUCTION INDOOR AIR QUALITY MANAGEMENT B.1.2. SECTION 01430 - CONSTRUCTION WASTE MANAGEMENT B.2. DEFINITIONS B.2.1. RECYCLED CONTENT: THE PERCENTAGE BY WEIGHT OF CONSTITUENTS THAT HAVE BEEN RECOVERED OR OTHERWISE DIVERTED FROM THE SOLID WASTE STREAM, EITHER DURING THE MANUFACTURING PROCESS (PRE-CONSUMER OR POST-INDUSTRIAL), OR AFTER CONSUMER USE (POST-CONSUMER). J. METALS K. GYPSUM WALLBOARD L. CARPET M. PAINT N. PLASTIC O. GLASS P. RIDGED FOAM INSULATION Q. BEVERAGE CONTAINERS 250 G/L E.2.5.2.1. ATTENDEES: THE CONTRACTOR AND RELATED CONTRACTOR PERSONNEL ASSOCIATED WITH THE WORK OF THIS SECTION, INCLUDING PERSONNEL TO BE IN CHARGE OF THE IAQ MANAGEMENT PROGRAM, ARCHITECT, OWNER AND SUCH ADDITIONAL PERSONNEL AS THE ARCHITECT OR OWNER DEEM APPROPRIATE. A.1. MANAGER: THE CONTRACTOR SHALL DESIGNATE AN ON-SITE PARTY (OR PARTIES) RESPONSIBLE FOR INSTRUCTING WORKERS AND OVERSEEING AND THE IAQ MANAGEMENT PLAN FOR THE PROJECT. A.2. PROGRESS MEETINGS: CONSTRUCTION RELATED IAQ PROCEDURES SHALL BE INCLUDED IN THE PRE-CONSTRUCTION AND CONSTRUCTION PROGRESS MEETING AGENDAS. A.3. DISTRIBUTION: THE CONTRACTOR SHALL DISTRIBUTE COPIES OF THE IAQ MANAGEMENT PLAN TO THE JOB SITE FOREMAN, EACH SUBCONTRACTOR, THE OWNER, AND THE ARCHITECT. A.4. INSTRUCTION: THE CONTRACTOR SHALL PROVIDE ON-SITE INSTRUCTION OF THE IAQ PROCEDURES AND ENSURE THAT ALL PARTICIPANTS IN THE CONSTRUCTION PROCESS UNDERSTAND THE IMPORTANCE OF THE GOALS OF THE IAQ MANAGEMENT PLAN. A. STANDARDS: COMPLY WITH INDUSTRY STANDARDS EXCEPT WHEN MORE RESTRICTIVE TOLERANCES OR SPECIFIED REQUIREMENTS INDICATE MORE RIGID STANDARDS OR MORE PRECISE WORKMANSHIP. B. PERFORM ALL WORK TO MEET OR EXCEED THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES, LAWS, REGULATIONS, SAFETY ORDERS, AND DIRECTIVES FROM AUTHORITIES HAVING JURISDICTION OVER THE WORK. C. PERFORM WORK WITH PERSONS QUALIFIED TO PRODUCE WORKMANSHIP OF SPECIFIED QUALITY. D. INSTALL PRODUCTS IN ACCORDANCE WITH THE MANUFACTURER / RECOMMENDATIONS. WHERE CONFLICT BETWEEN MANUFACTURER / RECOMMENDATIONS AND THE SPECIFIED REQUIREMENTS IS DISCOVERED, NOTIFY THE OWNER / REPRESENTATIVE IMMEDIATELY. E. EXAMINATION PRIOR TO INSTALLATION: E.1. PRIOR TO STARTING WORK, CAREFULLY INSPECT INSTALLED WORK OF OTHER TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK OF THIS SECTION MAY PROPERLY COMMENCE. NOTIFY THE OWNER / REPRESENTATIVE IN WRITING OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. E.2. DO NOT BEGIN INSTALLATION UNTIL ALL UNSATISFACTORY CONDITIONS ARE RESOLVED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF SITE CONDITIONS AND RESPONSIBILITY FOR DEFECTIVE INSTALLATION CAUSED BY PRIOR OBSERVABLE CONDITIONS. F. TESTING LABORATORY SERVICES: F.1. THE OWNER WILL ARRANGE FOR THE SERVICES OF AN INDEPENDENT TESTING LABORATORY TO INSPECT AND TEST THE WORK TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS. REPORTS OF ALL INSPECTIONS & TESTS SHALL BE SUBMITTED TO THE OWNER/REP. FOR REVIEW. F.2. CONTRACTOR'S RESPONSIBILITIES: F.2.1. COOPERATE WITH TESTING LABORATORY PERSONNEL, AND FURNISH ACCESS, TOOLS, SAMPLES, CERTIFICATIONS, TEST REPORTS, DESIGN MIXES, EQUIPMENT, STORAGE, AND ASSISTANCE AS REQUESTED BY THE TESTING LABORATORY. F.2.2. NOTIFY OWNER / REPRESENTATIVE AND TESTING LABORATORY 48 HOURS PRIOR TO EXPECTED TIME FOR OPERATIONS REQUIRING INSPECTION AND TESTING. WHEN TESTS OR INSPECTIONS CANNOT BE PERFORMED, THROUGH THE FAULT OF THE CONTRACTOR, REIMBURSE THE OWNER FOR THE ADDITIONAL COSTS INCURRED. F.2.3. REMOVE AND REPLACE ALL WORK FOUND NOT COMPLYING WITH THE CONTRACT DOCUMENTS. REMEDIES SHALL BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND CODE REQUIREMENTS. F.2.4. IF INITIAL TESTS AND INSPECTIONS INDICATE DEFICIENT WORK, THE CONTRACTOR SHALL REIMBURSE THE OWNER FOR THE COSTS OF ALL SUBSEQUENT TESTS AND INSPECTIONS RELATED TO THE DEFICIENCY. F.2.5. ALL DAMAGE WHICH MAY OCCUR TO THE WORK AS A RESULT OF NORMAL TESTING OPERATIONS SHALL BE REPAIRED TO MATCH SURROUNDING SURFACES. F.2.6. SCHEDULE TESTING AND INSPECTION SO THAT THE WORK OF TESTING AND INSPECTION PERSONNEL WILL BE AS CONTINUOUS AND BRIEF AS POSSIBLE. F.2.7. REIMBURSE THE OWNER FOR TRAVEL AND LODGING EXPENSES INCURRED FOR TESTING AND INSPECTION SERVICES PERFORMED OUTSIDE A RADIUS OF 100 MILES OF THE SITE. F.3. TESTS AND INSPECTIONS SHALL BE IN ACCORDANCE WITH CODE REQUIREMENTS & AS INDICATED IN THE INDIVIDUAL SPECIFICATIONS SECTIONS. A. TEMPORARY UTILITIES: A.1. PROVIDE TEMPORARY UTILITIES, SERVICES, AND CONSTRUCTION AS REQUIRED TO PERFORM THE WORK. COORDINATE ALL TEMPORARY FACILITIES AND CONTROLS WITH THE OWNER. A.2. ELECTRICITY: CONNECT TO EXISTING SERVICE. TAKE MEASURES TO CONSERVE ENERGY A.3. LIGHTING: PERMANENT LIGHTING MAY BE USED DURING CONSTRUCTION. PROVIDE ADDITIONAL TEMPORARY LIGHTING AS REQUIRED. MAINTAIN LIGHTING AND MAKE ROUTINE REPAIRS. A.4. HEATING & VENTILATION: PERMANENT SYSTEM MAY BE USED. MAINTAIN SYSTEM DURING OPERATION. PROVIDE ADDITIONAL TEMPORARY HEAT AS NECESSARY TO MAINTAIN CONDITIONS SUITABLE FOR CONSTRUCTION. A.5. TELEPHONE: PROVIDE TEMPORARY TELEPHONE SERVICE DURING CONSTRUCTION. A.6. WATER: UTILIZE EXISTING FACILITIES. A.7. SANITATION: EXISTING FACILITIES MAY BE USED BY CONSTRUCTION PERSONNEL PRIOR TO PROJECT TURNOVER, SUBJECT TO THOROUGH CLEANING AND REPAIR AS NECESSARY TO LEAVE FACILITIES IN NEW CONDITION. WHEN EXISTING FACILITIES ARE NOT OPERATIONAL OR ACCESSIBLE, PROVIDE SUITABLE PORTABLE SANITATION UNITS. B. REQUIRED SITE EQUIPMENT: B.1. COPIER: CONTRACTOR'S PREFERENCE. B.2. COMPUTERS: PC'S MUST BE EQUIPPED TO ADEQUATELY PERFORM ELECTRONIC CONSTRUCTION ADMINISTRATION TASKS AS DIRECTED BY THE OWNER AND THE OWNER / REPRESENTATIVE. SYSTEM SHALL INCLUDE ASSOCIATED PRINTER(S). AT LEAST ONE PRINTER SHALL HAVE 11 X 17 INCH GRAPHICS CAPABILITY. B.3. WINDOWS (CURRENT VERSIONS) & MICROSOFT OFFICE (CURRENT VERSIONS) FOR EACH COMPUTER. B.4. AN INTERNET SERVICE PROVIDER ACCOUNT (ISP), A HIGH SPEED, BROADBAND INTERNET CONNECTION, AND COMPONENTS TO FACILITATE THE NETWORKING OF THE COMPUTERS. B.5. ADOBE ACROBAT EXCHANGE (CURRENT VERSIONS), AT LEAST ONE STATION FOR INITIATING DOCUMENTS. B.6. ADOBE ACROBAT READER (CURRENT VERSIONS) FOR EACH COMPUTER. (FREE SOFTWARE) B.7. CELLULAR PHONE WITH NATIONAL ACCESS PLAN. B.8. DIGITAL CAMERA C. CONTROLS: C.1. DUST CONTROL: PROVIDE METHODS TO PREVENT DUST FROM PENETRATING INTO THE ATMOSPHERE, OCCUPIED SPACES, AND OTHER AREAS THAT WOULD BE ADVERSELY AFFECTED BY DUST. C.2. WATER CONTROL: COMPLY WITH APPLICABLE JURISDICTIONAL REQUIREMENTS REGARDING WATER USAGE, CONSERVATION, DETENTION, POLLUTION, AND PERMITS. C.3. SAFETY BARRIERS: PROVIDE AND MAINTAIN, ALL LAWFUL AND NECESSARY BARRICADES, RAILINGS, LIGHTS, WARNING SIGNS, SIGNALS, AND PRECAUTIONS AS MAY BE REQUIRED TO SAFEGUARD PERSONS, FROM INJURY. C.4. SMOKING: SMOKING SHALL BE PROHIBITED THROUGHOUT JOB SITE. C.5. NOISE: C.5.1. UNLESS APPROVED OTHERWISE, LIMIT EXCESSIVE NOISE PRODUCING ACTIVITIES TO NON-BUSINESS HOURS. C.5.2. USE SAWS AND HYDRAULIC IMPACTOR EQUIPMENT INSTEAD OF PNEUMATIC TOOLS AND COMPRESSORS TO REDUCE NOISE. C.5.3. EQUIPMENT SHALL BE MUFFLED FOR QUIET OPERATION NOT TO EXCEED 50 DECIBELS AT A DISTANCE OF 20 FEET FROM THE SOURCE. C.5.4. PORTABLE STEREO EQUIPMENT SHALL BE INAUDIBLE FROM OCCUPIED SPACES DURING BUSINESS HOURS D. PROVIDE TEMPORARY WEATHER-TIGHT CLOSURES OF OPENINGS IN EXTERIOR SURFACES TO PROVIDE ACCEPTABLE WORKING CONDITIONS AND PROTECTION FOR MATERIALS, TO ALLOW FOR TEMPORARY HEATING, AND TO PREVENT ENTRY OF UNAUTHORIZED PERSONS. WHERE NECESSARY, PROVIDE DOORS WITH SELF-CLOSING HARDWARE & LOCKS. EXTERIOR ENCLOSURES SHALL BE SUFFICIENTLY WELL CONSTRUCTED TO PREVENT BLOW OFF DURING INCLEMENT WEATHER, AND SHALL BE SEALED TIGHT TO PREVENT WATER PENETRATION AND EXCESSIVE AIR INFILTRATION. E. MAINTAIN PEDESTRIAN AND VEHICULAR ACCESS TO THE SITE AND WITHIN THE SITE TO PROVIDE FOR EMERGENCY VEHICLE ACCESS AND TO FACILITATE THE ADJACENT BUSINESS OPERATIONS. F. TEMPORARY CONSTRUCTION: F.1.1. OBTAIN APPROVAL FROM OWNER FOR ALL MODIFICATIONS TO EXISTING SYSTEMS OR FACILITIES NOT INDICATED. F.1.2. REMOVE TEMPORARY SYSTEMS OR FACILITIES WHEN USE IS NO LONGER REQUIRED. CLEAN AND REPAIR DAMAGE CAUSED BY INSTALLATION OR USE OF TEMPORARY SYSTEMS OR FACILITIES. (CONTINUED ON NEXT PAGE) RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt SPECIFICATIONS G501 SECTION 01770 PROJECT CLOSEOUT DIVISION 2 - SITEWORK SECTION 02221 SELECTIVE DEMOLITION (IF REQUIRED) DIVISION 3 - CONCRETE SECTION 03001 CONCRETE SECTION 03356 CONCRETE SEALER/HARDENER SECTION 03546 SLAB LEVELING DIVISION 5 - METALS SECTION 05400 COLD FORMED METAL FRAMING SECTION 05500 - METAL FABRICATIONS DIVISION 7: THERMAL AND MOISTURE PROTECTION SECTION 07200 BUILDING THERMAL INSULATION (AS REQUIRED) SECTION 01600 PRODUCT REQUIREMENTS SECTION 07515 ROOF PATCHING - BY LANDLORD'S SUBCONTRACTOR AT TENANT'S EXPENSE (U.O.N.) SECTION 07620 SHEET METAL FLASHING AND TRIM SECTION 07810 - SPRAYED-ON FIREPROOFING SECTION 07840 - FIRESTOPPING B.4. A SUBSTITUTION REQUEST CONSTITUTES A REPRESENTATION THAT CONTRACTOR: B.4.B. SHALL PROVIDE THE SAME WARRANTY FOR SUBSTITUTION AS FOR SPECIFIED PRODUCT. B.4.D. WAIVES CLAIMS FOR ADDITIONAL COSTS THAT MAY SUBSEQUENTLY BECOME APPARENT. B.4.E. AGREES TO PAY ALL COSTS OF REDESIGN RELATED TO THE SUBSTITUTION. B.5. SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN THEY ARE INDICATED OR IMPLIED ON SHOP DRAWINGS OR PRODUCT DATA SUBMITTALS. SECTION 01733 PATCHING AND REPAIR C. PATCHING OF EXISTING CONCRETE DECK: C.1. SEE LANDLORD'S CONSTRUCTION CRITERIA FOR ALL DECK PENETRATION WORK. C.2. INSTALL ALL DECK PENETRATIONS PER THE APPROPRIATE UL ASSEMBLIES - SEE L.L.'S CONSTRUCTION CRITERIA. C. COMPLETE THE FOLLOWING PRIOR TO SUBSTANTIAL COMPLETION: C.4. MAKE FINAL CHANGE OVER OF LOCKS AND TRANSMIT THE KEYS TO THE OWNER. ADVISE THE OWNER'S PERSONNEL OF CHANGE OVER IN SECURITY PROVISIONS. D. CLOSEOUT PROCEDURES: NOT D.2. AS PART OF THE INSTRUCTION FOR OPERATING EQUIPMENT, DEMONSTRATE THE FOLLOWING PROCEDURES: D.2.1. START-UP D.2.2. SHUT-DOWN D.2.3. EMERGENCY OPERATIONS D.2.4. NOISE AND VIBRATION ADJUSTMENTS D.2.5. SAFETY PROCEDURES D.2.6. ECONOMY AND EFFICIENCY ADJUSTMENTS D.2.7. EFFECTIVE ENERGY UTILIZATION E. CLOSEOUT SUBMITTALS: E.3. PRIOR TO FINAL PAYMENT, SUBMIT THE FOLLOWING AFFIDAVITS USING THE FORMS LISTED BELOW: E.3.1. CONTRACTOR'S AFFIDAVIT OF PAYMENT OF DEBTS AND CLAIMS AIA DOCUMENT G706. E.3.2. CONSENT OF SURETY TO FINAL PAYMENT AIA DOCUMENT G707. E.3.3. CONTRACTOR'S LIEN RELEASE, AND LIEN RELEASES FROM EACH SUBCONTRACTOR; CONTRACTOR'S AFFIDAVIT OF RELEASE OF LIENS AIA DOCUMENT G706A E.3.4. SUBMIT FINAL APPLICATION FOR PAYMENT IDENTIFYING TOTAL ADJUSTED CONTRACT SUM, PREVIOUS PAYMENTS, AND SUM REMAINING DUE. F. PROJECT RECORD DOCUMENTS: F.3. DOCUMENTS SHALL BE IN SAME FORMAT AS THE CONSTRUCTION DOCUMENTS. F.4. KEEP DOCUMENTS CURRENT; DO NOT PERMANENTLY CONCEAL ANY WORK UNTIL REQUIRED INFORMATION HAS BEEN RECORDED. G. RECORD DOCUMENT SUBMITTALS: G.1. ALL DATA OF 8-1/2" X 11" OR SMALLER IN SIZE SHALL BE SUBMITTED IN A THREE-RING BINDER PROPERLY INDEXED BY ITEM. G.3. SUBMIT THE FOLLOWING: G.3.1. ONE (1) SET OF ADDENDA BULLETINS AND CHANGE ORDERS WITH BACKUP. G.3.3. ONE (1) SET OF FIRE SPRINKLER SHOP DRAWINGS (FACTORY MUTUAL APPROVED ONLY IF REQUIRED BY LANDLORD). G.3.5. THREE (3) COPIES OF AIR BALANCE REPORT. G.3.7. TYPEWRITTEN LIST CONTAINING NAMES, ADDRESSES, AND PHONE NUMBERS OF ARCHITECT, ENGINEERS, GENERAL CONTRACTOR, AND SUBCONTRACTORS. G.3.9. ADDITIONAL QUANTITIES OF MATERIALS AS LISTED BELOW AND DELIVERED TO JOB SITE AND SIGNED FOR BY THE STORE MANAGER (WHERE APPLICABLE): G.3.9.1. RESILIENT TILE - TWENTY-FOUR (24) PIECES. G.3.9.2. CERAMIC TILE - TWELVE (12) PIECES OF FIELD TILE, ACCENT TILES, BULL NOSE & SPECIALTY TILES G.3.10. LANDLORD AND/OR OWNER PUNCHLIST AS COMPLETED AND APPROVED I. FINAL CLEANING: A.3. COMPLIANCE: COMPLY WITH SAFETY STANDARDS & GOVERNING REGULATIONS FOR CLEANING OPERATIONS. DO NOT DISCHARGE VOLATILE OR OTHER HARMFUL OR DANGEROUS MATERIALS INTO DRAINAGE SYSTEMS. REMOVE WASTE MATERIALS FROM SITE & DISPOSE OF IN A LAWFUL MANNER. A. VERIFY LOCATIONS OF EXISTING UTILITIES PRIOR TO DEMOLITION. B. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS REQUIRED TO ACCOMMODATE THE WORK. A. SUMMARY: CAST-IN-PLACE CONCRETE, INCLUDING REINFORCING, ACCESSORIES, AND FORMWORK. B. QUALITY ASSURANCE: B.1. PERFORM WORK IN ACCORDANCE WITH ACI 301, UNLESS INDICATED OR SPECIFIED OTHERWISE. C. MATERIALS: C.1. CONCRETE MATERIALS: C.1.1. CEMENT: ASTM C150, NORMAL - TYPE 1 PORTLAND CEMENT; GRAY COLOR. C.1.2. NORMAL WEIGHT FINE AND COARSE AGGREGATES: ASTM C33; SEVERE WEATHER EXPOSURE. REINFORCING STEEL: ASTM C615, GRADE 60. C.1.3. CHAIRS, BOLSTERS, BAR SUPPORTS, AND SPACERS: PLASTIC; SIZED AND SHAPED FOR STRENGTH AND SUPPORT OF REINFORCEMENT DURING INSTALLATION AND PLACEMENT OF CONCRETE. C.1.4. WATER: CLEAN AND NOT DETRIMENTAL TO CONCRETE. C.1.5. ADMIXTURES C.1.5.1. AIR-ENTRAINMENT: ASTM C 260. C.1.5.2. WATER REDUCER NORMAL: ASTM C 494/C 494M, TYPE A. C.1.5.3. ACCELERATOR: ASTM C 494/C 494M, TYPE C OR E, NON-CORROSIVE, NON-CHLORIDE. C.1.5.4. HIGH RANGE WATER REDUCER (SUPERPLASTICIZER): ASTM C 494/C 494M, TYPE F OR G AND SHALL BE OF THE SECOND OR THIRD GENERATION TYPE. SHALL BE BATCH PLANT ADDED TO EXTEND PLASTICITY TIME, AND REDUCE WATER 20 TO 30 PERCENT. C.1.6. ACCESSORIES: C.1.6.1. BONDING AGENT: TWO-COMPONENT MOISTURE INSENSITIVE, 100% SOLIDS EPOXY ADHESIVE WITH A SHEAR BOND TO CONCRETE STRENGTH OF OVER 1400 PSI. C.1.6.2. NON-SHRINK GROUTS: NON-CATALYZED NATURAL AGGREGATE GROUT; MINIMUM 7000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. C.1.6.3. FORM RELEASE AGENT: THAT WILL NOT BOND WITH, STAIN OR ADVERSELY AFFECT CONCRETE SURFACES, AND WILL NOT IMPAIR SUBSEQUENT TREATMENTS OF CONCRETE SURFACES WHEN APPLIED TO MOST FORMS OR FORM LINERS. C.1.6.4. CURING MATERIALS: WATERPROOF SHEET MATERIAL: C.1.6.4.1. WATERPROOF PAPER IN ACCORDANCE WITH ASTM C171; REINFORCED WATERPROOF KRAFT PAPER; WHITE COLOR AT EXTERIOR APPLICATIONS; BURKE KRAFT CURING PAPER TYPE I-SK-30, OR APPROVED. C.1.6.5. WATERSTOP TAPE: BENTONITE WATERSTOP: WATERSTOP-RX BY CETCO BUILDING MATERIALS GROUP (800-527-9948) OR "SUPERSTOP" BY TREMCO SEALANT/WATERPROOFING DIVISION, OR APPROVED (800 321 7906); SIZE AS RECOMMENDED BY THE MANUFACTURER FOR THE APPLICATION. D. CONCRETE MIX: D.1. MIX CONCRETE IN ACCORDANCE WITH ASTM C94/C94M, AND IN ACCORDANCE WITH THE REQUIREMENTS INDICATED ON THE DRAWINGS; MINIMUM 3000 PSI 28 DAY COMPRESSIVE STRENGTH. D.3. ALL SLABS PLACED AT AMBIENT TEMPERATURES BELOW 50 DEGREES F SHALL CONTAIN THE SPECIFIED ACCELERATOR. D.4. ALL CONCRETE REQUIRED TO BE AIR ENTRAINED SHALL CONTAIN AIR-ENTRAINING ADMIXTURE TO PRODUCE 4% TO 6% AIR. D.5. PROVIDE CONCRETE WITH A WATER/CEMENT RATIO OF 0.40 OR LOWER AT ALL INTERIOR SLABS. E. REINFORCEMENT: E.1. FABRICATE AS INDICATED AND IN ACCORDANCE WITH ACI 315. E.2. PLACE, SUPPORT, AND SECURE REINFORCEMENT AGAINST DISPLACEMENT. E.3. FOR SLABS ON GRADE, UNLESS INDICATED OTHERWISE, PROVIDE 6 X 6 - W2.9 X W2.9 WELDED WIREMESH. E.4. LOCATE REINFORCING SPLICES NOT INDICATED ON THE DRAWINGS AT POINTS OF MINIMUM STRESS. F. SLABS: F.1. CONTROL JOINTS: F.1.2. CONTROL JOINTS SHALL BE SAW CUT, TOOLED, UNLESS INDICATED OTHERWISE. F.1.3. RADIUS TOOLED CONTROL JOINTS TO MATCH EXPANSION JOINTS. F.1.5. AT EXTERIOR SIDEWALKS, PLACE CONTROL JOINTS AT MAXIMUM 5-FOOT INTERVALS. F.2. CONSTRUCTION JOINTS: PLACE AT CONTROL JOINT LOCATIONS. F.3. SLAB FINISHES: F.3.1. A. INTERIOR SLABS: LIGHT STEEL TROWEL. F.4. SLAB TOLERANCES: SLABS: CLASS B IN ACCORDANCE WITH ACI 301. SLAB SHALL BE LEVELED AND MUST HAVE A MAXIMUM SLOPE OF 1/4" VERTICAL OVER A 12'-0" HORIZONTAL SPAN A. SUMMARY: APPLICATION OF SEALER, HARDENER AND DENSIFIER FOR CONCRETE SURFACES. C. REFERENCES: C.1. ACI 308: STANDARD SPECIFICATION FOR CURING CONCRETE D. ACCEPTABLE PRODUCT: CONSOLIDECK LS DENSIFIER BY PROSOCO, INC. D.1. PROSOCO, INC. 3741 GREENWAY CIRCLE, LAWRENCE, KS 66046. (800) 255-4255, CUSTOMERCARE@PROSOCO.COM D.2. FORM: CLEAR, WATER LIKE LIQUID. E. PREPARATION: F. APPLICATION: F.1. CALCULATING TARGET COVERAGE RATE. F.1.1. CALCULATE TARGET COVERAGE RATE PER MANUFACTURER'S RECOMMENDATION. A. SECTION INCLUDES: A.1. UNDERLAYMENTS AS NECESSARY FOR LEVELING OF NEW OR EXISTING CAST-IN-PLACE CONCRETE SLABS, AS NECESSARY TO MEET SPECIFIED TOLERANCES. A.2. TOPPINGS AS NECESSARY FOR LEVELING OF NEW OR EXISTING SLABS AT LOCATIONS INDICATED TO RECEIVE CONCRETE SEALER ONLY. A.3. RAMPS AND TAPERS AS NECESSARY TO CORRECT LEVELS BETWEEN DISSIMILAR FINISH. B. ENVIRONMENT REQUIREMENTS B.1. MAINTAIN SURFACE AND AMBIENT TEMPERATURE OF BETWEEN 50 AND 80 DEGREES F FOR 24 HOURS BEFORE, DURING, AND 24 HOURS AFTER UNDERLAYMENT INSTALLATION. B.2. KEEP TRAFFIC OUT OF AREA IN WHICH UNDERLAYMENT IS BEING APPLIED OR CURED. C. SELF LEVELING, UNDERLAYMENT SYSTEM: SELF - LEVELING, POURABLE, CEMENT BASED MATERIAL, MINIMUM 28 DAY COMPRESSIVE STRENGTH 2,000 PSI: MINIMUM BOND STRENGTH 200 PSI; ONE OF THE FOLLOWING AS RECOMMENDED BY MANUFACTURER FOR CONDITIONS. C.1. MAPEI CORPORATION "ULTRAPLAN 1" OR "NOVOPLAN 2." C.2. ARDEX INCL "K-15" SELF-LEVELING UNDERLAYMENT CONCRETE C.3. LATICRETE INTERNATIONAL, INC. "LATICRETE 86 LATILEVEL THIN POUR UNDERLAYMENT" D. TROWELABLE UNDERLAYMENT SYSTEM: AS RECOMMENDED BY MANUFACTURER FOR CONDITIONS: D.1. MAPEI CORPORATION "MAPECEM 100" OR PLANITOP 10" D.2. ARDEX INC. "SD-P" FAST - SETTING UNDERLAYMENT. D.3. LATICRETE INTERNATIONAL, INC. "LATICRETE 220 MEDIUM BED MORTAR MIXED WITH LATICRETE 3701 LATEX MORTAR ADMIX." E. CEMENTITIOUS TOPPINGS: FOR REPAIR OF CONCRETE SURFACES AT LOCATIONS INDICATED TO REMAIN EXPOSED AS A WALK ABLE SURFACE: E.1. SELF-LEVELING TYPES: E.1.1. MAPEI CORPORATION "ULTRATOP". SELF-LEVELINGABRASION-RESISTANT TOPPING. E.1.2. ARDEX INC. "K-500" SELF-LEVELING CONCRETE TOPPING. E.2. TROWELABLE TYPES: E.2.1. MAPEI CORPORATION "MARECEM 100" FAST-SETTING TOPPING MORTAR E.2.2. ARDEX INC. "CD SELF-DRYING CONCRETE DRESSING. F. ACCESSORIES: FURNISH PRIMERS, PATCHING COMPOUNDS, AND SAND FILLERS AS RECOMMENDED BY THE UNDERLAYMENT MANUFACTURER FOR THE CONDITIONS OF THE PROJECT. G. THOROUGHLY MIX UNDERLAYMENT MATERIALS FOR EACH TYPE OF PRODUCT IN PROPER PROPORTIONS TO ACHIEVE SMOOTH HOMOGENEOUS MIX, FREE OF LUMPS. H. WITH THE EXCEPTION OF AREAS WHERE LEVELING CAN BE ACCOMPLISHED BY USED OF LATEX UNDERLAYMENT, AS SPECIFIED IN OTHER SECTIONS, INSTALL CEMENTITIOUS UNDERLAYMENT TO CONCRETE SLABS AS INDICATED ON THE DRAWINGS, AND AS NECESSARY TO LEVEL SLABS OR BRING SUBSTRATES TO PROPER ELEVATION. I. PREPARATION: I.1. INSPECT FLOOR TO VERIFY THAT DEMOLITION IS COMPLETE TO THE POINT WHERE WORK MAY PROGRESS. I.2. SURVEY FLOOR AS NECESSARY TO SET SCREEDS AND REFERENCE POINTS. IDENTIFY CONSTRUCTION JOINTS. PREPARE FOR UNDERLAYMENT AT ALL LOCATIONS WHERE FLOOR DOES NOT MEET SPECIFIED TOLERANCE REQUIREMENTS. I.3. ENSURE THAT SUBFLOOR IS CLEAN, DRY, HARD, SOUND, AND FREE OF OILS, OR OTHER SUBSTANCE THAT WOULD AFFECT PROPER BONDING AND CURING. J. APPLICATION J.1. INSTALL TROWELABLE UNDERLAYMENT AT LOCATIONS WHERE SLOPES ARE INDICATED AND AT OTHER LOCATIONS AS APPROPRIATE TO INSTALLATION CONDITIONS; INSTALL SELF-LEVELNESS. J.2. SET SCREEDS, MARKERS AND REFERENCE BLOCKS. SET SCREEDS AT ALL CONSTRUCTION AND CONTROL JOINTS TO ESTABLISH WEAKENED PLANE JOINTS IN UNDERLAYMENT. J.3. INSTALL PATCHING COMPOUNDS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE SUBSEQUENT FINISHING OF THE MATERIAL IS REQUIRED, FLOAT TO LEVEL SURFACE. DO NOT TROWEL. J.4. APPLY PRIMER TO ALL AREAS TO RECEIVE UNDERLAYMENT; REPEAT APPLICATION IF NECESSARY TO ACHIEVE PROPER BUILD. J.5. MIX MATERIALS AND POUR OR PUMP AND SQUEEGEE INTO PLACE TO ACHIEVE APPROPRIATE THICKNESS. PROVIDE FILL THICKNESS AS NECESSARY TO ALIGN CORK FLOORING WITH ADJACENT FLOOR SURFACES. J.6. FINISH TO A SMOOTH LEVEL SURFACE WITHIN TOLERANCES SPECIFIED FOR CONCRETE FLOORS. J.7. CURE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. J.8. TOLERANCES: AS SPECIFIED IN SECTION 03001. SLAB SHALL BE LEVELED AND MUST HAVE A MAXIMUM SLOPE OF 1/4" VERTICAL OVER A 12'-0" HORIZONTAL SPAN K. CLEANING: AS WORK PROCEEDS, CLEAN UP EXCESS MATERIALS, RUBBISH, AND SPLASH. A. SUMMARY: LIGHT-GAUGE COLD FORMED METAL FRAMING INDICATED ON THE DRAWINGS. B. QUALITY ASSURANCE: B.1. THE WORK OF THIS SECTION IS SUBJECT TO TESTING AND INSPECTION AS SPECIFIED IN 01450. B.2. FOR WELDED CONNECTIONS, USE ONLY AWS CERTIFIED WELDERS. B.3. REGULATORY REQUIREMENTS: FRAMING SYSTEM SHALL MEET THE REQUIREMENTS OF THE JURISDICTIONAL CODE AUTHORITIES. C. COMPONENTS: C.1. COLD FORMED LIGHT-GAUGE STEEL FRAMING: AS INDICATED ON THE STRUCTURAL DRAWINGS; G60 ZINC COATED FINISH IN ACCORDANCE WITH ASTM A 653/A 653M C.2. SCREWS: ASTM C954-07; SELF-DRILLING, SELF-TAPPING; PAN HEAD; GALVANIZED OR FLUOROPOLYMER COATED STEEL. C.3. ZINC RICH TOUCH-UP PAINT: "GALV-WELD", "GALVICAN","ZRC COLD GALVANIZED COMPOUND", OR APPROVED. D. INSTALLATION: D.2. ERECT METAL FRAMING AS INDICATED. D.3. WELDS SHALL BE IN ACCORDANCE WITH AWS D1.3. D.4. METAL FRAMING MEMBERS SHALL BE SAW OR SHEAR CUT. NO TORCH CUTTING IS PERMITTED. D.5. CONSTRUCT CORNERS WITH A MINIMUM OF 3 STUDS PER CORNER. D.6. FRAME BOTH SIDES OF EXPANSION AND SEISMIC JOINTS. DO NOT BRIDGE JOINTS WITH SYSTEM COMPONENTS OR ACCESSORIES. D.7. PROVIDE FRAMING AS REQUIRED TO FORM SOLID BACKING FOR ALL EDGES OF GYPSUM SHEATHING, AND TRIM ACCESSORIES. D.8. TOLERANCES: D.8.1. PLUMBNESS: PLUMB WITHIN 1/8 INCH IN 10 FEET. D.8.2. LOCATION: LOCATED WITHIN 1/4 INCH OF THE REQUIRED LOCATION. D.8.3. ALIGNMENT: STUD AND RUNNER FACES TO RECEIVE FINISH MATERIALS SHALL NOT VARY GREATER THAN 1/8 INCH FROM THE REQUIRED PLANE, WITH NO ABRUPT JOGS OR BREAKS IN PLANE. D.8.4. LEVEL: LEVEL WITHIN 1/8 INCH IN 10 FEET. D.9. ERECT MEMBERS IN ONE-PIECE FULL LENGTH. SPLICING AND WIRE TYING OF FRAMING COMPONENTS SHALL NOT BE USED. D.10. TOUCH-UP FIELD WELDS AND SCRATCHED OR DAMAGED GALVANIZING WITH ZINC RICH PAINT. D.11. ATTACH CROSS STUDS OR FURRING CHANNELS TO STUDS FOR ATTACHMENT OF WALL-MOUNTED ITEMS. A. GENERAL: PROVIDE MISCELLANEOUS METAL SHAPES AND FABRICATIONS AS REQUIRED AND NOT INCLUDED AS PART OF OTHER SECTIONS WITH ANCHORS AND ACCESSORIES FOR COMPLETE INSTALLATION. B. STEEL SHAPES: ASTM A36 STEEL. C. GROUT: PROVIDE NON-SHRINK, NON-METALLIC, PRE-MIXED, FACTORY PACKAGED, NON-STAINING, NON-CORROSIVE, NON-GASEOUS GROUT; TYPE SPECIFICALLY RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED. D. GENERAL FABRICATION: GRIND EXPOSED WELDS SMOOTH AND FLUSH WITH ADJACENT SURFACES; E. STEEL RAILINGS: WELDED TYPE WITH 1-1/2" OUTSIDE DIAMETER TUBE HANDRAILS; DESIGNED TO SUPPORT MINIMUM LATERAL FORCE OF 50 LBS/LIN FT UNIFORM LOAD AND 200 LBS AT ANY POINT WITHOUT PERMANENT SET OR DAMAGE. E.1. STANDARDS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ACCESS FOR PERSONS WITH DISABILITIES AND WITH NAAMM "PIPE RAILING MANUAL." F. PRE-ENGINEERED SUPPORT SYSTEMS: UNISTRUT OR GRINNELL/POWERSTRUT MANUFACTURED PRE-ENGINEERED SUPPORT SYSTEM CONSISTING OF MINIMUM 12 GAGE "C" CHANNEL SUPPORTS WITH ANCHORS, ATTACHMENTS, AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. DIVISION 6: WOOD AND PLASTIC SECTION 06100 ROUGH CARPENTRY - (USE ONLY NON-COMBUSTIBLE BLOCKING IN CONCEALED SPACES) A. SUMMARY: A.1. MISCELLANEOUS SHEATHING. A.2. WOOD BLOCKING AND NAILERS. B. QUALITY ASSURANCE: C. DIMENSION LUMBER: C.4.1. BLOCKING AND NAILERS: "UTILITY - LIGHT FRAMING," OR BETTER. D. PANEL MATERIALS: D.2. TERMINAL BACKBOARDS: APA AC GRADE EXTERIOR; FIRE RETARDANT TREATED. E. ACCESSORIES: E.1. FASTENERS: F. WOOD TREATMENT: F.1. WOOD PRESERVATIVE (PRESSURE TREATMENT): F.1.4. TREATED WOOD SHALL HAVE MAXIMUM MOISTURE CONTENT OF 19 F.2. FIRE RETARDANT TREATMENT: (ONLY FOR USE IN NON-COMBUSTIBLE CONSTRUCTION) F.2.5. APPROVED PRODUCTS: F.2.5.2. EXTERIOR FIREPROOFING: HOOVER TREATED WOOD PRODUCTS "EXTERIOR FIRE-X." G. BLOCKING AND NAILERS: (USE NON-COMBUSTIBLE BLOCKING AT CONCEALED LOCATIONS) G.3. BACKING: G.3.3. SECURE BACKING WITH EDGES ON FIRM BEARING. A. MATERIALS: A.2. TAPE: TO MATCH FOIL SCRIM KRAFT FACE; 2 INCH WIDTH. B. INSTALLATION: B.2. TRIM INSULATION NEATLY TO FIT SPACES. INSTALL WITHOUT GAPS OR VOIDS. B.3. INSTALLATION OF THERMAL BATT INSULATION: B.3.3. MECHANICAL FASTENING: B.3.3.2. MECHANICALLY OR ADHESIVELY BOND THE RETAINING PINS TO THE SUBSTRATE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. C. R VALUE SCHEDULE: C.1. PROVIDE INSULATION IN SUFFICIENT THICKNESS TO PROVIDE THE FOLLOWING R VALUES: C.1.1. VERTICAL ASSEMBLIES WITH HORIZONTAL HEAT FLOW: R19. SECTION 07260 - SLAB-ON-GRADE VAPOR RETARDER A. GENERAL: PROVIDE SLAB-ON-GRADE VAPOR RETARDER. C.1. PERMEANCE: MAXIMUM 0.025 PERMS, ASTM F1249 AND E154 TESTS. A. DELIVERY, STORAGE AND HANDLING: A.1. TRANSPORT AND HANDLE PRODUCTS BY METHODS TO AVOID PRODUCT DAMAGE. A.2. MANUFACTURED PRODUCTS SHALL REMAIN IN MANUFACTURER'S CONTAINERS OR PACKAGING, UNTIL READY FOR INSTALLATION. A.3. UNLESS SPECIFIED OTHERWISE, STORE PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. PRODUCT OPTIONS AND SUBSTITUTIONS: B.1. WHERE SPECIFICATIONS INDICATE A SINGLE PROPRIETARY PRODUCT, SUBSTITUTIONS WILL NOT BE CONSIDERED. FURNISH PRODUCTS SPECIFIED, EXCEPT WHERE "OR APPROVED" IS USED. B.2. SUBSTITUTIONS WILL BE CONSIDERED ONLY FOR THE FOLLOWING REASONS: B.2.A. A PRODUCT BECOMES UNAVAILABLE DUE TO NO FAULT OF THE CONTRACTOR. B.2.B. SUBSEQUENT INFORMATION OR CHANGES INDICATE THAT THE SPECIFIED PRODUCT WILL NOT PERFORM AS INTENDED. C. GENERAL PRODUCT INSTALLATION REQUIREMENTS: PERFORM WORK IN ACCORD WITH MANUFACTURER'S INSTRUCTIONS. DO NOT OMIT ANY PREPARATORY STEP OR INSTALLATION PROCEDURE UNLESS SPECIFICALLY MODIFIED OR EXEMPTED BY CONTRACT DOCUMENTS. B.4.C. WILL COORDINATE INSTALLATION AND MAKE OTHER CHANGES THAT MAY BE REQUIRED FOR WORK TO BE COMPLETE IN ALL RESPECTS. A. DEFINITIONS: PROJECT CLOSEOUT IS THE TERM USED TO DESCRIBE CERTAIN COLLECTIVE PROJECT REQUIREMENTS INDICATING COMPLETION OF THE WORK THAT ARE TO BE FULFILLED NEAR THE END OF THE CONTRACT TIME, IN PREPARATION FOR FINAL ACCEPTANCE AND OCCUPANCY OF THE WORK BY THE OWNER, AS WELL AS FINAL PAYMENT TO THE CONTRACTOR AND THE NORMAL TERMINATION OF THE CONTRACT. SPECIFIC REQUIREMENTS FOR INDIVIDUAL UNITS OF WORK ARE INCLUDED IN THE APPROPRIATE SECTIONS IN DIVISION 2 THROUGH 16. D.1. GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS: ARRANGE FOR EACH INSTALLER OF OPERATING EQUIPMENT AND OTHER WORK THAT REQUIRES REGULAR OR CONTINUING MAINTENANCE TO MEET AT THE SITE WITH THE OWNER'S PERSONNEL TO PROVIDE NECESSARY BASIC INSTRUCTION IN THE PROPER OPERATION AND MAINTENANCE OF THE ENTIRE WORK. WHERE INSTALLERS ARE EXPERIENCED IN THE REQUIRED PROCEDURES, INCLUDE INSTRUCTION BY THE MANUFACTURER'S REPRESENTATIVES. E.2. SUBMIT CERTIFICATE OF OCCUPANCY AND ALL OTHER CERTIFICATES OF APPROVAL REQUIRED BY THE GOVERNING AUTHORITIES INCLUDING INSPECTION REPORTS AND NOTICE OF COMPLETION. F.1. MAINTAIN A COMPLETE SET OF RECORD DRAWINGS THAT CLEARLY & NEATLY INDICATE EXACT INSTALLED LOCATIONS OF ITEMS THAT WILL BE CONCEALED IN THE WORK SUCH AS CONDUIT, PIPING, DUCTS, REINFORCING, MECHANICAL & ELECTRICAL EQUIPMENT, AND SIMILAR ITEMS. SHOW ALL CHANGES FROM THE CONTRACT DOCUMENTS & ALL UNCOVERED EXISTING CONDITIONS THAT WILL BE SUBSEQUENTLY CONCEALED. B.3. DOCUMENT EACH SUBSTITUTION REQUEST WITH COMPLETE DATA SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT DOCUMENTS. REQUESTS FOR SUBSTITUTION SHALL BE MADE IN WRITING TO THE ARCHITECT ON DOCUMENT 01601 - SUBSTITUTION REQUEST FORM, AVAILABLE SEPARATELY UPON REQUEST. LIMIT EACH REQUEST TO ONE PROPOSED PRODUCT OR SYSTEM. FOR SUBSTITUTIONS PRIOR TO AGREEMENT, SIGNATURE AND PROJECTED COST DATA ARE NOT REQUIRED. B.4.A. HAS INVESTIGATED PROPOSED PRODUCT AND HAS DETERMINED THAT IT MEETS OR EXCEEDS, IN ALL RESPECTS, THE SPECIFIED PRODUCT. B.6. ARCHITECT AND OWNER WILL DETERMINE ACCEPTABILITY OF PROPOSED SUBSTITUTION, AND WILL NOTIFY CONTRACTOR OF ACCEPTANCE OR REJECTION WITHIN A REASONABLE TIME. A. REPAIR EXISTING SURFACES AND CONSTRUCTION AS NECESSARY TO MAKE WORK COMPLETE, WITH ALL COMPONENTS MATCHING AND CONSISTENT. B. PROVIDE A SMOOTH, EVEN, AND INVISIBLE TRANSITION TO NEW CONSTRUCTION. WHEN FINISHED SURFACES ARE CUT SO THAT AN INVISIBLE TRANSITION WITH NEW WORK IS NOT POSSIBLE, TERMINATE EXISTING SURFACE ALONG THE NEAREST BREAKLINE, JOINT, OR CORNER. C.3. USE LANDLORDS SUBCONTRACTOR FOR PATCH & REPAIR OF ROOF PENETRATIONS AT TENANTS EXPENSE. (U.O.N.) B. TIME OF CLOSEOUT IS DIRECTLY RELATED TO SUBSTANTIAL COMPLETION. THEREFORE THE TIME OF CLOSEOUT MAY BE EITHER A SINGLE TIME PERIOD FOR THE ENTIRE WORK OR A SERIES OF TIME PERIODS FOR INDIVIDUAL ELEMENTS OF THE WORK THAT HAVE BEEN CERTIFIED AS SUBSTANTIALLY COMPLETE AT DIFFERENT DATES. THIS TIME VARIATION, IF ANY, SHALL BE APPLICABLE TO THE OTHER PROVISIONS OF THIS SECTION. C.1. SUBMIT SPECIFIC WARRANTIES, WORKMANSHIP MAINTENANCE BONDS, MAINTENANCE AGREEMENTS, FINAL CERTIFICATIONS & SIMILAR DOCUMENTS. C.2. OBTAIN AND SUBMIT RELEASES ENABLING OWNER'S FULL UNRESTRICTED USE OF THE WORK AND ACCESS TO SERVICES AND UTILITIES, WHERE REQUIRED, INCLUDING OCCUPANCY PERMITS, OPERATING CERTIFICATES, AND SIMILAR RELEASES. C.3. DELIVER TOOLS, SPARE PARTS, EXTRA STOCKS OF MATERIALS, AND SIMILAR PHYSICAL ITEMS TO THE OWNER. C.5. DISCONTINUE OR CHANGE OVER AND REMOVE TEMPORARY FACILITIES AND SERVICES FROM THE PROJECT SITE ALONG WITH CONSTRUCTION TOOLS AND FACILITIES, MOCK-UPS, AND SIMILAR ELEMENTS. C.6. COMPLETE FINAL CLEAN UP REQUIREMENTS, INCLUDING TOUCH UP OF PAINTING. TOUCH UP AND OTHERWISE REPAIR AND RESTORE MARRED EXPOSED FINISHES. E.1. IN ADDITION TO SUBMITTALS REQUIRED BY THE CONDITIONS OF THE CONTRACT, AND SUBMITTALS REQUIRED UNDER SECTION 01330, FURNISH THE FOLLOWING DOCUMENTS. F.2. RECORD DRAWINGS SHALL BE USED FOR NO OTHER PURPOSE AND SHALL BE STORED SEPARATELY FROM THOSE USED FOR CONSTRUCTION. G.3.2. ONE (1) SET OF ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING AS-BUILT (RECORD) DRAWINGS ON WHITE BOND PAPER, PLUS (1) COPY (SCANNED) IN PDF FORMAT ON CD ONLY. G.3.6. ONE (1) SET APPROVED CONTROL SCHEMATIC DRAWINGS WITH SEQUENCE OF OPERATION. (NOTE: ONLY IF DIFFERENT FROM ENGINEERED DRAWINGS.) G.3.8. ONE (1) COPY OF TYPEWRITTEN LIST CONTAINING BRAND NAMES & IDENTIFICATION NUMBERS FOR ALL PAINTS AND STAINS USED, WOOD FLOOR FINISHES, ACOUSTICAL CEILING TILES & ALL QUARRY AND CERAMIC TILE USED OF MATERIALS WHICH DIFFER FROM SPECIFICATIONS. G.3.4. ONE (1) SET OF OPERATING AND MAINTENANCE MANUALS OR MAJOR PIECES OF EQUIPMENT AND GUARANTEES PER SPECIFICATIONS IN BOUND FORM. OWNER RESERVES RIGHT TO RECEIVE ADDITIONAL MANUALS UPON REQUEST ON HVAC EQUIPMENT PUMPS, FANS, HW HEATERS, TRANSFORMERS, ELECTRICAL PANELS, AND EMERGENCY LIGHTING. H. MAINTENANCE MANUALS: ORGANIZE OPERATING AND MAINTENANCE DATA INTO SUITABLE SETS OF MANAGEABLE SIZE. BIND DATA INTO INDIVIDUAL BINDERS PROPERLY IDENTIFIED AND INDEXED. BIND EACH SET OF DATA IN A HEAVY-DUTY 2" THREE RING VINYL COVERED BINDER WITH POCKET FOLDERS FOR FOLDED SHEET INFORMATION. MARK THE APPROPRIATE IDENTIFICATION ON BOTH FRONT AND SPINE OF EACH BINDER, INCLUDE THE FOLLOWING TYPES OF INFORMATION IN OPERATION AND MAINTENANCE MANUALS: H.1. EMERGENCY INSTRUCTIONS, SPARE PARTS LIST, COPIES OF WARRANTIES, WIRING DIAGRAMS, TURN AROUND CYCLES, INSPECTION PROCEDURES, SHOP DRAWING'S AND PRODUCT DATA. A.2. REMOVAL OF PROTECTION: EXCEPT AS OTHERWISE INDICATED OR REQUESTED BY THE OWNER / REPRESENTATIVE, REMOVE TEMPORARY PROTECTION DEVICES AND FACILITIES WHICH WERE INSTALLED DURING THE COURSE OF THE WORK TO PROTECT PREVIOUSLY COMPLETED WORK WORK DURING THE REMAINDER OF THE CONSTRUCTION PERIOD. A.1. CLEANING: PROVIDE FINAL CLEANING OF THE WORK AT THE TIME INDICATED. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION EXPECTED FROM A NORMAL COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM. GENERAL: SPECIAL CLEANING REQUIREMENTS FOR SPECIFIC UNITS OF WORK ARE INCLUDED IN THE APPROPRIATE SECTIONS DIVISION 2 -16 GENERAL CLEANING DURING THE REGULAR PROGRESS OF THE WORK IS REQUIRED BY THE GENERAL CONDITIONS AND IS INCLUDED UNDER SECTION "TEMPORARY FACILITIES". D.2. ALL CONCRETE SHALL CONTAIN THE SPECIFIED WATER REDUCING OR HIGH RANGE WATER-REDUCING ADMIXTURE. B. QUALITY ASSURANCE: TEST A REPRESENTATIVE AREA OF NO LESS THAN 10FT BY 10FT (AND NO MORE THAN 10% OF THE TOTAL FLOOR AREA) TO CONFIRM SURFACE PREPARATION PROCEDURES, COVERAGE RATE, REACTION TIME, FINISHED APPEARANCE ETC. USE MANUFACTURER'S APPLICATION INSTRUCTIONS. LET TEST AREA DRY THOROUGHLY BEFORE INSPECTIONS. E.1. SURFACES TO BE TREATED MUST BE CLEAN, DRY AND ABSORBENT. CONFIRM SURFACE ABSORBENCY WITH A LIGHT WATER SPRAY. IF SURFACE DOES NOT WET UNIFORMLY, USE THE APPROPRIATE CONSOLIDECK SURFACE PREPARATION CLEANER OR MECHANICAL PROCESS TO REMOVE REMAINING SURFACE CONTAMINANTS. READ "PREPARATION" AND "SAFETY INFORMATION" SECTIONS IN THE MANUFACTURER'S PRODUCT DATA SHEET FOR CONSOLIDECK LS. REFER TO THE PRODUCT DATA SHEET FOR ADDITIONAL INFORMATION ABOUT APPLICATION OF CONSOLIDECK LS. DO NOT DILUTE OR ALTER. H. REPAIR ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO ADDITIONAL COST TO THE OWNER F. WHERE DEMOLITION INCLUDES REVISIONS TO THE BUILDING STRUCTURE, INCLUDING THE CUTTING OR EXISTING CONCRETE SLABS, COORDINATE ALL WORK WITH LANDLORD. E. DOCUMENT MANUFACTURER, FUNCTION, MODEL AND SERIAL NUMBER OF EACH PIECE OF MECHANICAL OR ELECTRICAL EQUIPMENT REMOVED FROM THE PREMISES. G. WHERE CUT EDGES OF THE EXISTING CONSTRUCTION WILL BE VISIBLE IN THE COMPLETED WORK, CUT IN UNIFORM STRAIGHT LINES. SAW CUT CONCRETE, INCLUDING TRENCHES FOR NEW CONDUIT AND PIPING IN FLOOR SLABS. D. CONTRACTOR SHALL REMOVE MATERIALS AND APPLIANCES INDICATED AS BEING RETAINED BY LANDLORD FOR REUSE. THESE SALVAGED ITEMS SHALL BE REMOVED CAREFULLY SO THAT THEY ARE NOT DAMAGED. CONTRACTOR SHALL TEMPORARILY STORE SALVAGE MATERIALS AND TRANSPORT THEM AS DIRECTED BY THE LANDLORD. C. EXCEPT WHERE NOTED OR SPECIFIED OTHERWISE, TAKE POSSESSION OF MATERIALS BEING DEMOLISHED, AND IMMEDIATELY REMOVE FROM SITE. F.1.1. MAKE JOINTS STRAIGHT; PERPENDICULAR OR PARALLEL TO BUILDING LINES AND SLAB EDGES, AS APPROPRIATE. F.1.4. CONTROL JOINTS SHALL PENETRATE THE SLAB A MINIMUM OF 1/4 THE THICKNESS OF THE SLAB AND SHALL BE 1/4 INCH WIDE AT SIDEWALKS. G.2. DO NOT USE RECORD DOCUMENTS FOR CONSTRUCTION PURPOSES. PROTECT FROM DETERIORATION AND LOSS IN A SECURE, FIRE-RESISTANT LOCATION, PROVIDE ACCESS TO RECORD DOCUMENTS FOR THE OWNER/REPRESENTATIVE REVIEW DURING NORMAL WORKING HOURS. G. FINISH: PRIME PAINT MISCELLANEOUS METAL. CLEAN SURFACES OF RUST, SCALE, GREASE AND FOREIGN MATTER PRIOR TO APPLYING GALVANIZED OR PAINTED FINISH. H. INSTALLATION: INSTALL SQUARE AND LEVEL, ACCURATELY FITTED AND FREE FROM DISTORTION AND DEFECTS. B.1. REGULATORY REQUIREMENTS: WORK SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENTLY ENFORCED BUILDING CODE, AS ADOPTED BY THE JURISDICTION. C.1. LUMBER SHALL BE MANUFACTURED IN ACCORDANCE WITH PS 20, AND SHALL BE STAMPED AND GRADED IN ACCORDANCE WITH SPIB, WWPA, WCLIB, OR NLGA GRADING RULES. C.2. MOISTURE CONTENT: KILN DRIED TO 19%%% MAXIMUM MOISTURE CONTENT, EXCEPT FOR MATERIAL WHOSE LEAST DIMENSION IS 4 INCHES THICK OR GREATER. C.3. SPECIES: SOUTHERN PINE, HEM-FIR, SPRUCE-PINE-FIR (SPF), OR DOUGLAS FIR LARCH, UNLESS INDICATED OR SPECIFIED OTHERWISE. C.4. ARCHITECTURAL LUMBER GRADES: UNEXPOSED NON-STRUCTURAL WOOD FRAMING AND BLOCKING INDICATED ON THE ARCHITECTURAL DRAWINGS SHALL BE GRADED AS FOLLOWS: D.1. PLYWOOD SHEATHING: APA RATED SHEATHING; CD GRADE; EXTERIOR; PLYWOOD OR ORIENTED STRAND BOARD, UNLESS APPROVED OTHERWISE; THICKNESS AS INDICATED. E.1.1. HOT-DIPPED GALVANIZED STEEL FOR EXTERIOR, HIGH HUMIDITY, AND TREATED WOOD LOCATIONS. F.1.1. PRESERVATIVE TREAT ALL WOOD IN CONTACT WITH CONCRETE, MASONRY, AND MOIST CONDITIONS. SITE TREAT SAWN ENDS WITH PRESERVATIVE TREATMENT F.1.2. PRESERVATIVE TREAT ALL WOOD AND PLYWOOD AT ROOF CONSTRUCTION OR OTHER WOOD IN MOIST CONDITIONS. SITE TREAT SAWN ENDS WITH PRESERVATIVE TREATMENT. F.1.3. AWPA TREATMENT C-22 USING CCA WATERBORNE PRESERVATIVE WITH 0.40 POUNDS PER CUBIC FOOT OF WOOD RETENTION. F.1.5. TREATED WOOD SHALL BEAR THE QUALITY STAMP OF AN INSPECTION AGENCY APPROVED BY THE JURISDICTIONAL CODE AUTHORITIES. F.2.3. TREATED LUMBER SHALL BE KILN DRIED TO A MAXIMUM MOISTURE CONTENT OF 19%TREATED PLYWOOD SHALL BE KILN DRIED TO A MAXIMUM MOISTURE CONTENT OF 15% F.2.4. EXTERIOR FIRE RETARDANT TREATED WOOD SHALL BE TREATED BY MEANS OF A SYSTEM THAT HAS BEEN DEMONSTRATED TO EXHIBIT NO INCREASE IN FIRE HAZARD CLASSIFICATION IN ACCORDANCE WITH ASTM E84 TEST AFTER HAVING BEEN SUBJECTED TO ACCELERATED WEATHER CONDITIONING IN ACCORDANCE WITH ASTM D2898 F.2.2. ALL FIRE RETARDANT TREATED WOOD MATERIALS SHALL BEAR A UL "FR-S" LABEL, OR A LABEL FROM AN APPROVED INSPECTION AGENCY CERTIFYING THAT THE MATERIAL MEETS THE REQUIREMENTS OF AWPA C-20 TYPE A FOR LUMBER AND AWPA C-27 TYPE A FOR PLYWOOD. F.2.1. FIRE RETARDANT TREAT ALL INTERIOR CONCEALED LUMBER AND PLYWOOD, AND OTHER WOOD AS INDICATED OR SPECIFIED. PROVIDE EXTERIOR FIREPROOFING AT ROOFTOP BLOCKING, NAILERS, CURBS, SHEATHING, AND OTHER LOCATIONS SUBJECT TO WETTING DURING CONSTRUCTION OPERATIONS. F.2.5.1. INTERIOR FIREPROOFING: CLEAR FINISH PRODUCT, HICKSON CORPORATION "DRICON", HOOVER TREATED WOOD PRODUCTS "PYRO-GUARD" OR OSMOSE WOOD PRESERVING CO. OF AMERICA, INC. "FLAME PROOF LHC." G.1. PROVIDE BLOCKING, NAILERS FOR ALL SHEATHING, ROOF CONSTRUCTION, METAL FLASHING, AND OTHER CONSTRUCTION AS INDICATED. G.2. WOOD BLOCKING: INSTALL WOOD BLOCKING TO RECEIVE MECHANICAL FASTENERS FOR SUPPORT OF ELECTRICAL FIXTURES AND EQUIPMENT, CABINETS, DOORSTOP PLATES, WOOD BASE, WAINSCOTS, COAT HOOKS, AND ALL OTHER WALL AND CEILING MOUNTED COMPONENTS, UNLESS SPECIFIED OTHERWISE. G.3.1. PLYWOOD BACKING SHALL BE USED IN LIEU OF BLOCKING AT LOCATIONS OF WALL-MOUNTED STANDARDS AND SHELVING. G.3.2. BACKING SHALL BE MOUNTED OVER FACE OF STUDS AND SHALL BE CONTINUOUS OVER ENTIRE PLANE OF WALL; 1/2 INCH THICKNESS. A.1. THERMAL BATT INSULATION: PREFORMED GLASS FIBER BATT WITH FSK-25 REFLECTIVE MEMBRANE ON ONE SIDE. A.3. OWENS CORNING, FIRE BATT / MINERAL WOOL 2" THICK INSTALLATION AT AREA'S AS DEFINED IN THE DOCUMENTS. COORDINATE & CONFIRM COVERAGE AREAS AND REQUIRED THICKNESS WITH LANDLORD PRIOR TO INSTALLATION. D.1. INSTALL LIGHT GAUGE STRUCTURAL FRAMING IN ACCORDANCE WITH ASTM C955, UNLESS INDICATED OR SPECIFIED OTHERWISE. D.12. INSTALL FRAMING BETWEEN STUDS FOR ATTACHMENT OF ELECTRICAL BOXES AND OTHER MECHANICAL AND ELECTRICAL ITEMS. COUNTERSINK FASTENERS; MAKE EXPOSED BUTT JOINTS HAIRLINE JOINTS WHERE MECHANICALLY FASTENED. FIT AND SHOP ASSEMBLE IN LARGEST PRACTICAL SECTIONS FOR DELIVERY. B.1. INSTALL INSULATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND AS INDICATED. B.3.1. INSTALL INSULATION WITH VAPOR BARRIER TOWARD WARM SIDE OF BUILDING SPACES. VAPOR BARRIER SHALL BE CONTINUOUS. TAPE SEAL TEARS OR CUTS IN VAPOR BARRIER B.3.2. AT METAL STUD FRAMING, INSERT THE INSULATION EDGES TIGHTLY INTO THE STUD CHANNELS FOR A FRICTION FIT. WHERE INSULATION BUTTS THE BACKSIDE OF STUD CHANNELS, CONTINUOUSLY TAPE INSULATION FLANGES TO THE EXPOSED METAL STUD FLANGE. B.3.3.1. AT LOCATIONS WHERE NO FRAMING IS PRESENT TO SUPPORT THE INSULATION, PROVIDE METAL IMPALING PINS AND RETAINERS TO HOLD THE INSULATION FIRMLY IN PLACE. B.3.3.3. SPACE PINS AT MAXIMUM 24 INCHES ON CENTER ALONG THE EDGES AND WITHIN THE FIELD OF THE BLANKET. PLACE EDGE PINS WITHIN 6 INCHES FROM THE EDGE OF THE BATT.B.3.4. PACK BATT INSULATION IN SHIM SPACES AT PERIMETER OF WINDOW ASSEMBLY TO MAINTAIN CONTINUITY OF THERMAL BARRIER. C.1.2. THE ABOVE R-VALUES ARE REQUIRED FOR THE TOTAL INSULATION IN THE ASSEMBLY. THE BATT INSULATION MAY BE COMBINED WITH OTHER INSULATION IN THE ASSEMBLY TO OBTAIN THE TOTAL R-VALUE REQUIRED. THE R-VALUE IS FOR THE INSULATION ONLY AND MAY NOT INCLUDE AIR FILM VALUES, AND R-VALUES FOR OTHER MATERIALS IN THE ASSEMBLY SUCH AS CONCRETE AND GYPSUM BOARD. B. MANUFACTURER: FORTIFIBER CORP./MOISTOP ULTRA; STEGO INDUSTRIES, INC./STEGO WRAP (15 MIL); RAVEN INDUSTRIES, INC./VAPOR BLOCK # VB 15 (15 MIL BLUE). C. VAPOR RETARDER: ASTM E1745, CLASS A WATER RESISTANT RETARDER CONSISTING OF 15 MIL POLYOLEFIN FILM. D. JOINT SEALER: PRESSURE SENSITIVE TAPE AS RECOMMENDED BY VAPOR RETARDER MANUFACTURER AND PROVIDING COMPARABLE PREMEANCE TO VAPOR RETARDER. E. SAND BED: CLEAN DRY NATURAL SAND; FREE FROM SILT, CLAY, LOAM, FRIABLE OR SOLUBLE MATERIALS, AND ORGANIC MATTER. F. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS; TAPE JOINTS AND TEARS IN VAPOR RETARDER. D.3. VOC CONTENT: 0 G/L D.4. PREMIUM EAGLE COAT - CLEAR, MANUFACTURED BY EAGLE F.2. APPLICATION: F.2.2. PRODUCT TO BE APPLIED PER MANUFACTURER'S RECOMMENDATION & PER SITE CONDITIONS. F.2.1 BEFORE FIRST COAT OF PROSOCO DENSIFIER IS APPLIED, A COAT OF PREMIUM EAGLE COAT SHALL BE APPLIED TO TREATED SURFACES USING A GARDEN PUMP SPRAYER. WAIT FOUR HOURS. AFTER FOUR HOURS, PROVIDE A COAT OF PROSOCO DENSIFIER. APPLY SECOND COAT AFTER THE FIRST HAS DRIED. ALL APPLICATIONS SHALL BE DONE PER MANUFACTURER'S RECOMMENDATION (CONTINUED ON NEXT PAGE) A. SUMMARY: A.1. PATCHING OF EXISTING ROOF AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. A.2. ALL ROOF WORK, INCLUDING MISCELLANEOUS PATCHING, SHALL BE PERFORMED IN COMPLIANCE WITH LANDLORD'S REQUIREMENTS. B. ROOFING MATERIALS: B.1. UNLESS APPROVED OTHERWISE, NEW ROOFING MATERIALS SHALL MATCH THE EXISTING MATERIALS. B.2. ACCESSORIES: B.2.1. FLEXIBLE BOOT PIPE FLASHING: PORTALS PLUS (708/766-5240; 800/774-5240) "ALUMI-FLASH" WITH EPDM BOOTS, OR APPROVED; SIZED TO MATCH PIPE DIAMETER; SPLIT TYPE WITH SEALING HARDWARE WHERE NECESSARY FOR INSTALLATION AT PENETRATING ITEMS THAT CANNOT BE DISCONNECTED FOR TOP. ACCESS. FURNISH STAINLESS STEEL DRAW BANDS, ADAPTERS, CONNECTION HARDWARE, AND SEALANTS AS NECESSARY FOR A COMPLETE AND WEATHER TIGHT INSTALLATION. C. PROTECTION: C.1. PROTECT EXISTING CONSTRUCTION PRIOR TO STARTING WORK. C.1.0.1. LAP SUITABLE PROTECTIVE MATERIAL AT LEAST 3 INCHES. C.1.0.2. SECURE PROTECTIVE COVERINGS AGAINST WIND. C.1.0.3. LEAVE PROTECTIVE COVERING IN PLACE FOR DURATION OF ROOFING WORK. C.2. RESTORE TO ORIGINAL CONDITION OR REPLACE WORK OR MATERIALS DAMAGED DURING HANDLING OF ROOFING MATERIALS. D. REMOVAL OF EXISTING ROOFING: D.1. REMOVE EXISTING ROOFING TO ACCOMMODATE NEW CONSTRUCTION. D.2. REMOVE EXISTING SYSTEMS TO EXPOSE SUBSTRATES. CLEAN AND PREPARE SURFACES IN MANNER REQUIRED FOR INSTALLATION OF NEW SYSTEMS. D.3. REMOVE RESULTING DEMOLISHED MATERIALS FROM ROOFING AREAS & JOBSITE ON THE DAY THEY ARE REMOVED. DISPOSE OF IN A LEGAL MANNER. D.4. PROVIDE CHUTES, TARPS, AND OTHER MATERIALS TO PREVENT DAMAGING OR STAINING OF BUILDING COMPONENTS THAT ARE TO REMAIN. D.5. EXISTING SURFACES SHALL BE MADE SMOOTH, FIRM, DRY, AND FREE FROM DIRT, FOREIGN MATERIALS, SHARP PROJECTIONS, OR VOIDS. E. PATCHING OF EXISTING ROOF: E.1. PROVIDE NEW MATERIALS AS REQUIRED TO FORM A COMPLETE AND CONTINUOUS ROOF ASSEMBLY. E.2. UNLESS APPROVED OTHERWISE, NEW ROOFING MATERIALS SHALL MATCH THE EXISTING MATERIALS. E.3. PROVIDE ADDITIONAL TAPERED CONSTRUCTION AS REQUIRED TO FORM NEW NON-PONDING DRAINAGE PATTERNS AROUND NEW CONSTRUCTION. COORDINATE THE PLACEMENT OF NEW DRAINS. E.4. SEAL OFF ALL ROOF AREAS AT THE END OF EACH WORKDAY. E.5. PERFORM WORK IN ACCORDANCE WITH THE GUARANTEE REQUIREMENTS OF THE EXISTING ROOF ASSEMBLY. CONTACT THE BUILDING LANDLORD TO VERIFY GUARANTEE REQUIREMENTS. A. QUALITY ASSURANCE: A.1. APPLICATOR: COMPANY SPECIALIZING IN SHEET METAL FLASHING WORK WITH 5 YEARS MINIMUM EXPERIENCE. A.2. UNLESS INDICATED OR SPECIFIED OTHERWISE, PERFORM WORK IN ACCORDANCE WITH THE RECOMMENDATIONS OF SMACNA. B. MATERIALS: B.1. PRE FINISHED GALVANIZED STEEL: ASTM 653 / A653M - 09; G90 -05 GALVANIZED FINISH; 24 GAGE UNLESS NOTED OTHERWISE; FACTORY PRE FINISHED WITH 70 % RESIN KYNAR 500 OR HYLAR 5000 COATING, STANDARD COLOR AS SELECTED BY THE OWNER / REPRESENTATIVE. B.2. ACCESSORIES: B.2.1. FASTENERS: GALVANIZED STEEL; SOFT NEOPRENE WASHERS AT EXPOSED FASTENERS. FINISH EXPOSED FASTENERS SAME AS FLASHING METAL. B.2.2. BUTYL RUBBER SEALANT: ONE OF THE FOLLOWING: B.2.2.1. CURTAIN WALL SEALANT, BY TREMCO; B.2.2.2. ADCOSEAL BP-300, BY ADCO PRODUCTS, INC. B.2.3. FLEXIBLE FLASHING: B.2.3.1. W.R. GRACE "VYCOR PLUS.". B.2.3.2. MONSEY BAKOR "BLUESKIN" 40 MIL THICKNESS. B.2.3.3. DUPONT COMPANY "TYVEK FLEXWRAP." C. FABRICATION: C.1. FABRICATE ALL FLASHING TO DETAIL AND AS SPECIFIED. USE MINIMUM 24 GAGE PRE FINISHED GALVANIZED STEEL SHEET UNLESS INDICATED OR SPECIFIED OTHERWISE. C.2. PARAPET CAPS: JOINTS IN ACCORDANCE WITH SMACNA PLATE 77, FIGURE A; BUTT AND BACKUP PLATE JOINT J2; SHOP FINISHED. C.3. NON-MOVING JOINTS: C.3.1. SHOP FABRICATE TO THE GREATEST PRACTICAL EXTENT. C.3.2. LAP JOINTS ONE INCH, MINIMUM; ACCURATELY CUT AND FIT AS NECESSARY TO MAINTAIN PROFILE; EMBED CONTACT SURFACES IN SEALANT; RIVET WITH STAINLESS STEEL OR COLOR MATCHED COATED STEEL POP RIVETS AT 3 TO 4 INCHES O.C. D. D. INSTALLATION: D.1. INSTALL STARTER AND EDGE STRIPS, AND CONTINUOUS CLEATS BEFORE STARTING INSTALLATION. D.2. PROVIDE FLEXIBLE FLASHING UNDER ALL HORIZONTAL COPINGS AND FLASHING. D.3. FASTENING: D.3.1. SECURE FLASHING USING CONTINUOUS CLEATS AT EXPOSED LOCATIONS WHENEVER POSSIBLE. USE EXPOSED FASTENERS ONLY IN SEMI-EXPOSED LOCATIONS, UNLESS APPROVED BY THE OWNER / REPRESENTATIVE. D.3.2. EXPOSED FASTENERS SHALL BE PLACED AT 8 INCHES ON CENTER THROUGH SLOTTED HOLES. D.3.3. FOR FASTENING INTO WOOD, USE GASKETED SCREWS. D.3.4. FIT FLASHING TIGHT IN PLACE. MAKE CORNERS SQUARE, SURFACES TRUE AND STRAIGHT IN PLANES, AND LINES ACCURATE TO PROFILES. D.3.5. INSTALL FLASHING WITH PROVISION FOR PLUS OR MINUS 1/16 INCH THERMAL MOVEMENT AT EACH END; PROVIDE EXPANSION JOINTS AT 12'-0" O.C. MAX. D.3.6. SEAL CONCEALED LAP JOINTS IN WITH TWO PARALLEL BEADS OF BUTYL SEALANT; USE BUTYL SEALANT WHERE BEDDING SEALANT IS INDICATED OR REQ'D. A. GENERAL: CEMENTITIOUS OR MINERAL FIBER SPRAY-ON FIREPROOFING AS REQUIRED BY APPLICABLE CODES FOR TYPE I FIRE RESISTIVE CONSTRUCTION; NO ASBESTOS PERMITTED. B. MANUFACTURERS: W.R. GRACE/MONOKOTE OR ALBI MANUFACTURING DIVISION STANCHEM/DURASPRAY. C. INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST RESULTS AS REQUIRED TO PROVIDE REQUIRED FIRE RATINGS. A. SUMMARY: FIRESTOPPING MATERIAL FOR PENETRATIONS IN FIRE-RATED CONSTRUCTION. B. SYSTEM DESCRIPTION: B.1. EACH FIRESTOPPING SYSTEM SHALL BE SELECTED TO MAINTAIN FIRE RATING OF THE ASSEMBLY IN WHICH IT USED. B.2. FIRESTOPPING SYSTEMS SHALL BE RESILIENT AS NECESSARY TO ACCOMMODATE DIFFERENTIAL MOVEMENT BETWEEN ASSEMBLIES. C. QUALITY ASSURANCE: C.1. PRIOR TO INSTALLATION OF FIRE STOPPING SYSTEMS OBTAIN APPROVAL FROM THE JURISDICTIONAL CODE AUTHORITIES FOR THE FIRE STOPPING SYSTEMS AND APPLICATIONS PROPOSED. NOTIFY THE OWNER / REPRESENTATIVE IF APPROVAL CANNOT BE OBTAINED. C.2. FIRESTOPPING: TESTED IN ACCORDANCE WITH ASTM E119 - 08A, ASTM E814 - 08B, OR UL 1479 TO MEET THE HOURLY FIRE RATINGS OF THE CONSTRUCTION BEING SEALED. PROVIDE F RATED ASSEMBLIES, EXCEPT WHERE T-RATED ASSEMBLIES ARE REQUIRED BY THE CODE AUTHORITY. C.3. FIRESTOPPING SYSTEMS SHALL BE UL LISTED ASSEMBLIES. D. PRODUCTS: D.1. FIRESTOPPING SYSTEMS: SYSTEMS MEETING THE REQUIREMENTS SPECIFIED AND SUITABLE FOR THE CONDITIONS INDICATED. E. INSTALLATION: E.1. PROVIDE FIRESTOPPING AT MECHANICAL, ELECTRICAL, AND PLUMBING PENETRATIONS ON THE DRAWING'S. E.2. INSTALL FIRESTOPPING IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND AS NECESSARY TO MEET THE SPECIFIED FIRE RATING REQUIREMENTS. E.3. WHERE FIRESTOPPING IS USED TO SEAL AROUND PENETRATIONS THROUGH WATERPROOF MEMBRANES, INSTALL TO MAINTAIN INTEGRITY OF WATERPROOF BARRIER. E.4. PATCHING OF HOLES IN EXISTING CONSTRUCTION: FINISH CONSTRUCTION. A.1.1. WHERE FIRESTOPPING SYSTEMS ARE USED TO FILL FLOOR OPENINGS IN OCCUPIED AREAS, PROVIDE MINIMUM 16 GAGE SHEET METAL COVER AS NECESSARY TO SUPPORT FLOOR LOADS AND TO PREVENT DAMAGE TO THE FIRE STOPPING ASSEMBLIES. SECURE SHEET METAL AS NECESSARY TO PREVENT IRREGULARITIES FROM TELEGRAPHING THROUGH THE FLOOR FINISHES OVER THE SHEET METAL. E.4.1. FILL OPEN HOLES WHICH REMAIN AFTER REMOVAL OF EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING COMPONENTS, PATCH AND REPAIR HOLES AS NECESSARY TO MATCH THE ADJACENT CONSTRUCTION AND TO MAINTAIN THE FIRE RATING OF THE ASSEMBLIES. FIRESTOPPING SYSTEMS MAY BE USED TO FILL HOLES THAT WILL BE CONCEALED IN THE RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt SPECIFICATIONS G502 SECTION 07850 FIRE RATED JOINTS SECTION 07920 JOINT SEALANTS DIVISION 8 - DOORS AND WINDOWS SECTION 08115 HOLLOW METAL DOORS AND FRAMES SECTION 08305 ACCESS DOORS SECTION 08710 DOOR HARDWARE SECTION 08800 - GLAZING DIVISION 9: FINISHES SECTION 09111 LIGHT GAUGE METAL SUPPORT FRAMING SECTION 09250 GYPSUM BOARD SECTION 08350 SLIDING GRILLE SPECIFICATION SECTION 09510 ACOUSTICAL CEILINGS SECTION 09650 - LUXURY VINYL TILE A. SUMMARY: B. REFERENCES: B.1. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) B.1.1. E119 - METHOD FOR FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS. B.2. UNDERWRITERS LABORATORIES (UL) B.2.1. STANDARD 2079 - TESTS FOR FIRE RESISTANCE OF BUILDING JOINT SYSTEMS. C. SYSTEM DESCRIPTION: D. QUALITY ASSURANCE: E. FIRE RATED CONSTRUCTION JOINT ASSEMBLIES: E.1. METAL STUD PARTITION HEAD CONSTRUCTION JOINT ASSEMBLY: E.1.1. SYSTEM: BASED ON UL ASSEMBLIES LISTED ON THE DRAWINGS. E.1.3. GYPSUM BOARD: AS SPECIFIED IN SECTION 09250. E.1.4. FILL, VOID, OR CAVITY MATERIAL: AS LISTED IN THE FIRE RATED ASSEMBLY . F. INSTALLATION: B. SEALANTS: B.1. TYPE S - NEUTRAL CURE SILICONE SEALANTS: B.1.2. PECORA, 890 ARCHITECTURAL SILICONE SEALANT. C. ACCESSORY MATERIALS: D. PREPARATION: D.3. PRIME AS REQUIRED FOR PROPER BOND TO SUBSTRATE MATERIALS. E. INSTALLATION: E.1. SEALANT BEADS SHALL HAVE A SECTIONAL WIDTH TO DEPTH RATIO OF 2 TO 1. G. SCHEDULE: G.4. TYPE SM: PROVIDE AT JOINTS AROUND COUNTERTOPS IN RESTROOMS. A. SUMMARY: HOLLOW STEEL DOORS AND FRAMES. B. REFERENCES: B.2. STEEL DOOR INSTITUTE (SDI): B.2.1. SDI-100 - STANDARD STEEL DOORS AND FRAMES. B.2.2. SDI-105 - RECOMMENDED ERECTION INSTRUCTIONS FOR STEEL FRAMES. B.3. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) C. QUALITY ASSURANCE: C.1. CONFORM TO REQUIREMENTS OF SDI-100. C.2. REGULATORY REQUIREMENTS: D. MATERIALS: E. DOORS: E.1. SDI-100, SEAMLESS DESIGN. E.3. CORE: E.3.2. EXTERIOR DOORS: POLYSTYRENE OR POLYURETHANE FOAM CORE. F. HOLLOW METAL KNOCK DOWN FRAMES (PROVIDE AS INDICATED ON DOOR SCHEDULE) F.1. FRAME MATERIAL: COLD ROLLED STEEL, FOR INTERIOR FRAMES. COLD ROLLED STEEL, ELECTRO-GALVANIZED FOR EXTERIOR FRAMES. F.2. FRAME PROFILE: (S) STANDARD SERIES INTERIOR, 20 GAGE C SERIES, 18 GAGE EXTERIOR G. FULLY WELDED FRAMES: G.1. DESIGN: DOUBLE RABBET, UNLESS INDICATED OTHERWISE; FULLY WELDED. G.2. EXTERIOR FRAMES: MINIMUM 14 GAGE. H. FABRICATION: H.1. SHOP-FABRICATE UNITS TO ACCOMMODATE THE HARDWARE SPECIFIED IN SECTION 08710. H.6. PROVIDE METAL RAIN HOOD FOR EXTERIOR DOOR FRAMES. H.7. ATTACH FIRE RATED LABEL TO EACH FRAME AND DOOR UNIT. I. INSTALLATION OF FRAMES: I.2. COORDINATE WITH WALL CONSTRUCTION FOR ANCHOR PLACEMENT. I.3. INSTALL ACCESSORIES. I.4. INSTALLATION TOLERANCES: I.4.2. INSTALL DOORS PLUMB AND LEVEL TO 1/16 INCH IN 7 FEET. J. DOOR INSTALLATION: J.2. INSTALL DOORS PLUMB AND SQUARE. J.5. FIT HOLLOW METAL DOORS IN ACCORDANCE WITH SDI 100. J.6. DOOR AND HARDWARE INSTALLATION IS SPECIFIED IN SECTION 08710. A. ACCEPTABLE MANUFACTURERS: A.1. AS INDICATED ON DRAWINGS B. DOOR TYPES: B.1. AS INDICATED ON DRAWINGS B.1.1. SIZE AS INDICATED ON DWGS D. INSTALLATION: D.2. COORDINATE ACCESS REQUIREMENTS WITH OTHER TRADES AND LANDLORD. C. CODES: C.3. PROVIDE SMOKE SEALS AS REQUIRED AT EACH FIRE-RATED OPENING. H. IN GENERAL, UNLESS OTHERWISE INDICATED, FINISHES SHALL BE AS FOLLOWS: H.1. CORRIDORS AND BACK OF HOUSE: AS INDICATED ON DRAWINGS H.2. SALES FLOOR: AS INDICATED ON DRAWINGS J. HARDWARE: J.1. HARDWARE IS SCHEDULED ON THE DRAWINGS. J.2. COMPLY WITH REQUIREMENTS INDICATED BELOW. K. BUTTS: K.2. PROVIDE FULL THREADED WOOD SCREWS FOR WOOD DOORS AND/OR JAMBS. L.1. PROVIDE NEW CYLINDER AT EACH EXISTING DOOR THAT HAS DEADLOCK OR LOCKSET. L.2. PROVIDE LOCK STRIKES WITH MINIMUM PROJECTION TO PROTECT TRIM. L.3. PROVIDE WROUGHT BOXES FOR LOCKSETS AND DEADLOCKS. L.4. PROVIDE DEADLOCKS WITH ARMORED FRONTS. L.5. FUNCTION AS INDICATED IN HARDWARE GROUPS. M. DOOR CLOSER: AS INDICATED ON THE DRAWINGS, NO SUBSTITUTIONS ALLOWED. M.1. ALL OVERHEAD CLOSER TO BE MOUNTED ON INTERIOR SIDE OF DOOR. NO THRU BOLTS. M.6. OPENER SETTINGS: 101-140 DEGREE M.7. BACKCHECK SETTING: 140 DEGREE M.8. CLOSING SPEED: DELAY SPEED M.9. OPENING FORCE: 5 POUNDS MAX N. DOOR STOPS AND OVERHEAD STOPS: N.1. LOCATE FLOOR STOPS FREE FROM FOOT TRAFFIC. O. THRESHOLDS: AS INDICATED ON THE DRAWINGS, NO SUBSTITUTIONS ALLOWED. O.1. MANUFACTURER: AS INDICATED ON DRAWINGS O.2. TYPES AS SCHEDULED IN THE DRAWINGS. O.3. INSTALL THRESHOLDS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. P. MISCELLANEOUS: P.1. PROVIDE SILENCERS FOR ALL DOORJAMBS, 3 FOR SINGLE JAMBS AND 4 FOR DOUBLE JAMBS. R. ADJUSTMENTS AND TESTING: R.3. TESTING: TESTING DEVICE SHALL REMAIN IN THE POSSESSION OF THE OWNER. D. MANUFACTURERS: PPG, PILKINGTON, OR NIPPON. K. PROVIDE TEMPERED SAFETY GLASS WHEN LOCATED IN THE FOLLOWING AREAS: A. SYSTEM DESCRIPTION: A.3. STRUCTURAL REQUIREMENTS: A.3.1. DESIGN LOADS: B. DEFLECTION REQUIREMENTS: C. MATERIALS: C.3. SCREWS: SELF-TAPPING; LOW PROFILE HEAD. C.4. OTHER FRAMING MATERIALS: FURNISH IN ACCORDANCE WITH ASTM C754-09. C.4.1. SECURE RUNNERS WITH FASTENERS AT MAXIMUM 24 INCHES O.C. D. PARTITION FRAMING: D.1. RUNNERS: D.10. STUD SPLICING NOT PERMISSIBLE. D.12. STUD BRIDGING: E. BACKING: E.1. BLOCKING AND BACKING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 06100. F. STUD AND RUNNER CEILING FRAMING: F.2. SCREW-FASTEN FRAMING AT EACH JOINT. F.4. PROVIDE BRACING TO MEET SEISMIC REQUIREMENTS AS REQUIRED BY LOCAL CODE G. SUSPENDED CEILING FRAMING: G.6. PROVIDE BRACING TO MEET SEISMIC REQUIREMENTS. H. INSTALLATION TOLERANCES: H.2. LOCATE ASSEMBLIES WITHIN 1/4 INCH OF REQUIRED LOCATIONS. A. SUMMARY: INTERIOR GYPSUM BOARD. B. MATERIALS: B.1. GYPSUM BOARD: B.1.2. STANDARD BOARD: ASTM C36/C36M-99E1 B.1.3. WATER RESISTANT BOARD: ASTM C630/C630M-00 B.2. ACCESSORIES: B.2.4. SCREWS: ASTM C1002-07 B.2.5. ZINC CONTROL JOINTS C. INSTALLATION: C.3. SCREW-FASTEN BOARD TO FRAMING, UNLESS APPROVED OTHERWISE. C.4. INSTALLATION OF GYPSUM BOARD AT CURVED SURFACES. D. FINISHING: D.1. PROVIDE FINISHING IN ACCORDANCE WITH GA 214. D.3. LEVELS OF FINISH: D.3.2. LEVEL 4: PROVIDE AT BACK OF HOUSE AREAS. A.1. FIRE RATED CONSTRUCTION JOINT ASSEMBLIES IN FIRE-RATED CONSTRUCTION, INCLUDING JOINTS AT THE FOLLOWING LOCATIONS: A.1.1. WHERE PARTITION HEADS MEET THE UNDERSIDE OF OVERHEAD FLOOR OR ROOF CONSTRUCTION. C.1. EACH FIRE RATED CONSTRUCTION JOINT ASSEMBLY SHALL BE SELECTED TO MAINTAIN FIRE RATING OF THE ASSEMBLY IN WHICH IT USED. C.2. EACH FIRE RATED CONSTRUCTION JOINT ASSEMBLY SHALL BE RESILIENT AS NECESSARY TO ACCOMMODATE DIFFERENTIAL MOVEMENT BETWEEN ASSEMBLIES. D.1. FIRE RATED CONSTRUCTION JOINT ASSEMBLIES: SUCCESSFULLY TESTED IN ACCORDANCE WITH ASTM E119, INCLUDING HOSE STREAM TEST, TO MEET THE HOURLY RATING OF THE CONSTRUCTION BEING SEALED. D.2. FIRE RATED CONSTRUCTION JOINT ASSEMBLIES AT PARTITION HEADS SHALL HAVE BEEN SUCCESSFULLY TESTED IN ACCORDANCE WITH THE DYNAMIC REQUIREMENTS OF UL 2079, INCLUDING HOSE STREAM TEST, TO MEET THE HOURLY FIRE RATINGS OF THE CONSTRUCTION BEING SEALED. A.1.2. JOINTS IN FIRE RATED CONCRETE OR MASONRY WALLS. REQUIREMENTS FOR FIRE RATED CONSTRUCTION JOINT ASSEMBLY COMPONENTS PROVIDED IN OTHER SECTIONS. E.1.2. FIRE RATED RUNNER: "FIRE TRAK" BY FIRE TRAK CORPORATION, KIMBALL MN (612-398-7800). F.1. INSTALL CONSTRUCTION JOINT ASSEMBLIES IN ACCORDANCE WITH THE FIRE RATED ASSEMBLIES LISTED, AND AS NECESSARY TO MEET THE SPECIFIC FIRE RATING REQUIREMENTS. F.2. COORDINATE INSTALLATION OF INTEGRAL COMPONENTS AS NECESSARY TO ENSURE THE FIRE RATING OF THE ASSEMBLIES. A. PERFORM WORK IN ACCORDANCE WITH ASTM C1193, UNLESS SPECIFIED OTHERWISE OR RECOMMENDED OTHERWISE BY THE SEALANT MANUFACTURER B.1.1. DOW CORNING, 790 SILICONE BUILDING SEALANT, OR 795 SILICONE STRUCTURAL GLAZING AND WEATHERPROOFING SEALANT. B.2. TYPE PTNS: ASTM C920, TYPE M, GRADE NS, CLASS 25; PECORA "DYNATRED," TREMCO "HPL," OR APPROVED; CUSTOM COLORS TO MATCH ADJACENT GROUT COLOR. B.3. TYPE A: ASTM C834; TREMCO "ACRYLIC LATEX CAULK", PECORA "AC-20", SONNEBORN "SONOLAC" OR APPROVED. B.4. TYPE SM: MILDEW RESISTANT SILICONE SEALANT: USDA APPROVED; DOW CORNING 786 BY DOW CHEMICAL, GE SANITARY SEALANT OR APPROVED; CLEAR. C.2. JOINT CLEANER: NON-CORROSIVE AND NON-STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER; COMPATIBLE WITH JOINT FORMING MATERIALS. C.1. PRIMER: NON-STAINING TYPE, RECOMMENDED BY SEALANT MANUFACTURER TO SUIT APPLICATION. C.3. JOINT FILLER: CLOSED CELL POLYETHYLENE FOAM; ROUND PROFILE; THICKNESS: 130% OF JOINT WIDTH. C.4. BOND BREAKER: PRESSURE SENSITIVE TAPE RECOMMENDED BY SEALANT MANUFACTURER TO SUIT APPLICATION. D.1. CLEAN AND PREPARE JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REMOVE LOOSE MATERIALS AND OTHER FOREIGN MATTER THAT MIGHT IMPAIR ADHESION OF SEALANT. D.2. APPLY MASKING TIGHTLY AROUND JOINTS TO PROTECT ADJACENT SURFACES FROM EXCESS SEALANT. D.4. PLACE BACKING MATERIALS TO ACHIEVE PROPER SEALANT WIDTH/DEPTH RATIOS. USE BOND BREAKER WHERE REQUIRED. E.2. INSTALL TYPE PTNS SEALANT FULL DEPTH IN TILE EXPANSION JOINTS WITH NO BACKER ROD. E.3. TOOL JOINTS CONCAVE, UNLESS INDICATED OTHERWISE. FINISH FREE OF AIR POCKETS, FOREIGN EMBEDDED MATTER, RIDGES, AND SAGS. F. PROTECT SEALANT IN JOINTS SUBJECT TO DIRT, MOISTURE, AND TRAFFIC DURING THE SEALANT CURING PROCESS. PROTECTION SHALL BE ABLE TO RESIST TRAFFIC WHILE REMAINING SECURELY IN POSITION. G.1. TYPE S: PROVIDE AT ALL EXTERIOR JOINTS; STANDARD COLORS AS SELECTED BY OWNER / REPRESENTATIVE. G.2. TYPE PTNS: PROVIDE AT ALL EXPANSION JOINTS IN STONE AND TILE; CUSTOM COLORS TO MATCH GROUT SAMPLES SUBMITTED BY THE TILE INSTALLER. G.3. TYPE A: PROVIDE AT ALL INTERIOR JOINTS, UNLESS SPECIFIED OTHERWISE; STANDARD COLORS TO MATCH ADJACENT CONSTRUCTION. B.1. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA): NFPA 80 - FIRE DOORS AND WINDOWS. B.3.1. A366 - SPECIFICATION FOR STEEL, CARBON, COLD ROLLED SHEET, COMMERCIAL QUALITY. B.3.2. A569 - SPECIFICATION FOR STEEL, CARBON (0.15 MAXIMUM PERCENT), HOT ROLLED SHEET AND STRIP, COMMERCIAL QUALITY. C.2.1. INSTALLED FRAME AND DOOR ASSEMBLY SHALL CONFORM TO NFPA 80 FOR FIRE RATED CLASS INDICATED. C.2.2. WHERE DOORS ARE NOTED WITH AN HOURLY FIRE RESISTANCE RATING, PROVIDE DOOR AND FRAME ASSEMBLIES LABELED BY UNDERWRITER'S LABORATORY OR ANY OTHER TESTING LABORATORY APPROVED BY THE LOCAL CODE AUTHORITIES, TO MEET THE HOURLY FIRE RATING NOTED. ASSEMBLIES SHALL MEET JURISDICTIONAL REQUIREMENTS FOR POSITIVE PRESSURE. C.2.3. WHERE A HOLLOW METAL FRAME IS USED AS A GLAZED OPENING IN AN INTERIOR FIRE RATED WALL ASSEMBLY, THE FRAME SHALL BE LABELED TO MATCH THE FIRE RATING REQUIRED FOR A DOOR ASSEMBLY IN THE FIRE RATED WALL, EXCEPT IN A 1 HOUR FIRE RATED CORRIDOR WALL ASSEMBLY, THE GLAZED FRAME SHALL BE LABELED TO A 45 MINUTE RATING. IN A 1-HOUR FIRE RATED CORRIDOR WALL ASSEMBLY, WHERE THE DOOR FRAME IS INTEGRAL WITH THE GLAZED FRAME, THE FRAME SHALL HAVE A 45 MIN. RATING. C.3. INCLUDE "S" LABEL ON FIRE RATED DOOR ASSEMBLIES WHICH ARE LOCATED AT 1 HOUR RATED EXIT CORRIDORS WHEN REQUIRED BY LOCAL JURISDICTION. C.4. MEMBERS OF THE STEEL DOOR INSTITUTE AND OF THE NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURER'S, SUBJECT TO COMPLIANCE WITH THE SPECIFIED REQUIREMENTS. D.1. STEEL SHEET: COLD ROLLED ASTM A366, OR HOT ROLLED PICKLED AND OILED SHEET CONFORMING TO ASTM A569. E.2. MINIMUM 18-GAGE FACE SHEETS FOR INTERIOR DOORS; MINIMUM 16 GAGE FACE SHEETS FOR EXTERIOR DOORS. M.5. CLOSURE PRESSURE: SET TO 5 POUNDS FOR EXTERIOR DOORS AND 5 LBS FOR INTERIOR DOORS, PER CURRENT REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT. M.4. PROVIDE FULL METAL COVERS AT OVERHEAD CLOSER UNLESS OTHERWISE INDICATED; MATCH FINISH OF LOCKSET/LATCHSET AT EACH DOOR. M.3. SIZES SHALL BE AS RECOMMENDED BY THE MANUFACTURER. CLOSER SHALL HAVE A 5-YEAR UNCONDITIONAL GUARANTEE. FINISH SHALL MATCH LOCKSETS M.2. PROVIDE MOUNTING BRACKETS AND PROPER LENGTH ARMS TO SUIT ALL CONDITIONS. PROVIDE ARM OPTIONS AS SCHEDULED OR RECOMMENDED BY MANUFACTURER. L.6. DEAD BOLTS AT EXTERIOR DOORS SHALL HAVE A MINIMUM THROW OF 1 INCH AND MINIMUM EMBEDMENT OF 3/4 INCH. L. LOCKSETS, DEADLOCKS, CYLINDERS AND PADLOCKS: AS INDICATED ON THE DRAWINGS, NO SUBSTITUTIONS ALLOWED K.3. BUTT WIDTHS LISTED ARE MINIMUM. PROVIDE BUTTS OF WIDER THROW TO SUIT CONDITIONS FOR 180 DEGREE OPERATION OF DOORS, STRUCTURAL CONDITIONS PENDING. K.1. PROVIDE BUTTS ON EXTERIOR DOORS WITH NON-REMOVABLE PINS (SET SCREW IN BARREL, PIN NON REMOVABLE WHEN DOOR IS CLOSED), AND SAFETY STUD. I. GENERAL: CONSTRUCTION MASTERKEY ALL LOCKSETS AND CYLINDER ITEMS; PROVIDE 6 CONSTRUCTION MASTERKEYS. F. FACTORY REPRESENTATIVES FOR DOOR CLOSER, EXIT BOLTS, AND LOCKSETS SHALL BE AVAILABLE DURING THE CONSTRUCTION TO INSTRUCT THE CONTRACTOR ON THE PROPER METHOD OF INSTALLATION OF THEIR MATERIALS. THEY SHALL INSPECT AND ADJUST THEIR MATERIALS AT THE COMPLETION OF THE WORK, AND SUPPLY PROPER MAINTENANCE MANUALS TO THE OWNER. C.2. HARDWARE FOR FIRE-RATED OPENINGS SHALL ALSO BE IN COMPLIANCE WITH ALL FIRE AND BUILDING CODES APPLICABLE TO THE DISTRICT IN WHICH THE BUILDING IS LOCATED. PROVIDE ONLY HARDWARE WHICH HAS BEEN TESTED AND LISTED BY UL FOR THE TYPES AND SIZES OF DOORS REQUIRED, AND WHICH COMPLIES WITH THE REQUIREMENTS OF THE DOOR AND DOOR FRAME LABELS. C.1. ALL FINISH HARDWARE SHALL COMPLY WITH APPLICABLE LOCAL AND/OR STATE CURRENT BUILDING CODES. A. SUPPLIER: FINISH HARDWARE SHALL BE SUPPLIED BY RECOGNIZED BUILDERS' HARDWARE SUPPLIER WHO HAS BEEN FURNISHING HARDWARE IN THE SAME AREA AS THE PROJECT FOR A PERIOD OF NOT LESS THAN TWO YEARS. THE SUPPLIER'S ORGANIZATION SHALL INCLUDE A MEMBER OF THE AMERICAN SOCIETY OF ARCHITECTURAL HARDWARE CONSULTANTS WHO IS AVAILABLE AT ALL REASONABLE TIMES DURING THE COURSE OF THE WORK TO MEET WITH THE OWNER, OWNER / REPRESENTATIVE, OR CONTRACTOR FOR PROJECT HARDWARE CONSULTATION. D.1. PROVIDE ACCESS DOORS IN THE LOCATIONS INDICATED, AND FOR ACCESS TO BALANCING AND FIRE DAMPERS, TRAP PRIMERS, VALVES, FANS, TERMINAL UNITS, AND OTHER EQUIPMENT REQUIRING PERIODIC INSPECTION OR MAINTENANCE THROUGH FINISHED WALLS OR CEILING, WHETHER INDICATED OR NOT. G. FURNISH 2 SETS OF SPECIAL TOOLS FOR INSTALLATION AND MAINTENANCE OF HARDWARE. TOOLS FOR MAINTENANCE AND ADJUSTMENTS ARE TO BE DELIVERED TO THE OWNER UPON COMPLETION OF THE WORK. D. DELIVERY: DELIVER ALL HARDWARE IN MANUFACTURERS' ORIGINAL UNOPENED UNDAMAGED PACKAGES, CLEARLY IDENTIFYING MANUFACTURER, BRAND NAME & CONTENTS E. IN ADDITION TO REQUIRED ONE-YEAR WARRANTY UNDER CONDITIONS OF THE CONTRACT, FURNISH 5-YEAR UNCONDITIONAL GUARANTEES FOR ALL DOOR CLOSER, UNDER PROVISIONS OF SECTION 01700 B. INSTALLER: FINISH HARDWARE SHALL BE INSTALLED ONLY BY EXPERIENCED TRADESMEN IN COMPLIANCE WITH TRADE UNION JURISDICTIONS, EITHER AT THE DOOR AND FRAME FABRICATION PLANT OR AT THE PROJECT SITE. C. MINIMUM SIZES: PROVIDE ACCESS DOORS IN SIZES INDICATED. WHEN NOT INDICATED PROVIDE 12" X 12" SIZE FOR HAND ACCESS, AND 24" X 24" SIZE FOR MAN ENTRY. J.4. INSTALL ROSES, KICK PLATES, CLOSER, AND OTHER SURFACE MOUNTED HARDWARE ONLY AFTER DOOR FINISHING IS COMPLETE AND FINISHES ARE COMPLETELY CURED. E.3.1. INTERIOR DOORS:VERTICAL STEEL STIFFENERS W/SOUND DEADENING FILL BETWEEN, OR RESIN IMPREGNATED KRAFT PAPER HONEYCOMB CORE. F.3. FRAME CASINGS: MATERIAL; STEEL CASINGS WITH CORNER ALIGNMENT CLIPS. TYPE; STANDARD STEEL MODEL TA-8 WITH 1/4 INCH REVEAL FIT FACTORY ASSEMBLED UNITS WITH MITERGARD CORNER ALIGNMENT CLIPS. G.3. INTERIOR FRAMES: MINIMUM 16 GAGE FOR FRAMES OF DOOR OPENINGS UP TO AND INCLUDING 4 FEET IN WIDTH; 14 GAGE FOR FRAMES GREATER THAN 4 FEET IN WIDTH. G.4. PROVIDE EXTENDED RETURN LEG AT EXTERIOR OPENINGS AS INDICATED TO SUPPORT SEALANT SYSTEMS. H.2. FABRICATE FRAMES AND DOORS WITH HARDWARE REINFORCEMENT PLATES WELDED IN PLACE. REINFORCE FOR BUTTS, CLOSER, AND OTHER SIMILAR MOVING HARDWARE ITEMS. REINFORCING SHALL BE MINIMUM 3/16-INCH STEEL PLATE. REINFORCE EACH BUTT WITH MINIMUM 10-1/2 X 1-1/2 INCH PLATE ON HINGE SIDES OF BOTH DOOR AND FRAME. REINFORCE FOR CLOSER THE FULL WIDTH OF THE DOOR. H.3. REINFORCE FRAMES WIDER THAN 48 INCHES WITH ROLL FORMED STEEL CHANNELS FITTED TIGHTLY INTO FRAME HEAD, FLUSH WITH TOP. H.4. CLOSE TOP AND BOTTOM EDGES OF DOORS WITH STEEL CHANNEL MINIMUM 16-GAUGE EXTENDING FULL WIDTH OF DOOR, SPOT-WELDED TO BOTH FACES. CLOSE TOP EDGES OF EXTERIOR DOORS FLUSH WITH STEEL FILLER CAP; SEAL JOINTS WATERTIGHT. H.5. FINISH AT EXTERIOR UNITS: MODIFIED EPOXY ESTER BAKED-ON PRIMER TO RECEIVE URETHANE COATING SPECIFIED IN SECTION 09900; OR "SERIES 69 EPOXOLINE II," BY TNEMEC, OR SERIES 888" BY CARBOLINE. I.1. INSTALL FRAMES IN ACCORDANCE WITH SDI-105 AND IN ACCORDANCE WITH LABELING REQUIREMENTS. I.4.1. MAXIMUM DIAGONAL DISTORTION: 1/16 INCH MEASURED WITH STRAIGHT EDGE, CORNER TO CORNER. J.1. FIT AND PREPARE DOORS FOR INSTALLATION IN ACCORDANCE WITH THE DOOR MANUFACTURER'S PRINTED INSTRUCTIONS. J.3. FABRICATE FOR 1/8 INCH CLEARANCE AT HEAD AND EACH JAMB, 1/8 INCH BETWEEN PAIRS OF DOORS, 3/8 INCH CLEARANCE FROM HARD SURFACE FINISH FLOOR AND 3/4 INCH FROM HARD SURFACE BENEATH DOORS AT OPENINGS INDICATED TO RECEIVE CARPETING. E.4. PROVIDE CONTINUOUSLY WELDED SEAMLESS EDGES. NO PLASTIC FILLERS WILL BE ACCEPTED. Q. FURNISH FOR EACH DOOR THE ITEMS SCHEDULED WITHIN THE DESIGNATED HARDWARE GROUPS AS SHOWN ON THE DRAWINGS. R.3.1. TEST CLOSER FOR COMPLIANCE WITH REQUIREMENTS OF SECTION 08710, INCLUDING OPENING FORCE AND CLOSING SPEED REQUIRED BY JURISDICTIONAL AUTHORITIES. R.1. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OF FUNCTION OF EVERY UNIT. LUBRICATE MOVING PARTS WITH GRAPHITE TYPE LUBRICANT UNLESS OTHERWISE RECOMMENDED BY THE HARDWARE MANUFACTURER. REPLACE UNITS THAT CANNOT BE ADJUSTED AND LUBRICATED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE. R.2. ADJUST CLOSER PRESSURES AS SPECIFIED IN SECTION 08710, UNLESS OTHERWISE REQUIRED BY JURISDICTIONAL AUTHORITIES. R.3.2. PROVIDE TESTING DEVICE, OPERATE TEST AT EACH DOOR, AND PROVIDE A WRITTEN REPORT ON RESULTS OF TESTS. K.2. GLASS WHOSE NEAREST VERTICAL EDGE IS WITHIN 24 INCHES OF A DOOR OPENING, AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE. K.1. IN ALL HINGED AND SLIDING GLAZED DOORS, EXCEPT WHERE WIRE GLASS IS REQUIRED TO MEET FIRE RATING REQUIREMENTS. J. INSTALLATION: COMPLY WITH GLASS MANUFACTURER RECOMMENDATIONS, FGMA, AND APPLICABLE CODES; METAL SHALL NOT TOUCH GLASS. I. SETTING BLOCKS AND SPACERS: NEOPRENE OR EPDM, SILICONE COMPATIBLE WHERE IN CONTACT WITH SILICONE SEALANT. H. GLAZING SEALANT: DOW, GE, OR TREMCO; ONE COMPONENT SILICONE GLAZING SEALANT; PROVIDE AS RECOMMENDED BY SEALANT MANUFACTURER FOR APPLICATIONS INDICATED. G. FRAMELESS MIRRORS: ASTM C1036 MIRROR QUALITY Q2 CLEAR FLOAT GLASS; FULL SILVER COATING, COPPER COATING AND ORGANIC COATING; NOMINAL 1/4" THICK. F. CLEAR FIRE RATED GLASS: UL LISTED FOR FIRE RESISTANCE AND TESTED AND APPROVED FOR IMPACT RESISTANCE BASED ON ANSI Z97.1; NOMINAL 1/4" THICK. E. TEMPERED GLASS: ASTM C1048, KIND FT, FULLY TEMPERED, SELECT GLAZING QUALITY; SAFETY GLASS; NOMINAL 1/4" UNLESS OTHERWISE INDICATED. C. CODES: SAFETY GLAZING SHALL COMPLY WITH CONSUMER PRODUCT STANDARD 16 CFR 1201, AND SHALL HAVE PASSED ANSI Z97.1. B. STANDARDS: COMPLY WITH FLAT GLASS MARKETING ASSOCIATION (FGMA) "GLAZING MANUAL" AND "GLAZING SEALING SYSTEMS MANUAL." A. GENERAL: PROVIDE GLASS AND GLAZING ACCESSORIES NOT PROVIDED ELSEWHERE AND AS REQUIRED FOR COMPLETE INSTALLATION. K.3. GLASS UNITS LARGER THAN 9 SQUARE FEET IN AREA, WHOSE BOTTOM EDGE IS WITHIN 18 INCHES OF A FLOOR OR WALKING SURFACE WHICH IS IN TURN WITHIN 36 INCHES MEASURED HORIZONTALLY FROM THE GLASS UNIT. A.1. SELECT FRAMING SYSTEMS, GAUGES, SUPPORTS, BRACING, AND CONNECTIONS AS NECESSARY TO RESIST THE DESIGN LOADS SPECIFIED. A.2. PARTITION FRAMING SHALL CONFORM TO THE WIDTHS INDICATED, UNLESS APPROVED OTHERWISE. PROVIDE HEAVIER GAGES AND DECREASED STUD SPACING AS NECESSARY TO MEET THE STRUCTURAL REQUIREMENTS. A.3.1.1. INTERIOR CEILING ASSEMBLIES: 5 POUNDS PER SQUARE FOOT UNIFORM LIVE LOAD, PLUS DEAD LOADS. A.3.1.2. INTERIOR PARTITIONS WITHOUT WALL MOUNTED CASEWORK: 5 POUNDS PER SQUARE FOOT UNIFORM LIVE LATERAL LOAD. A.3.1.3. INTERIOR PARTITIONS WITH WALL MOUNTED CASEWORK: 5 POUNDS PER SQUARE FOOT UNIFORM LIVE LATERAL LOAD, PLUS CASEWORK DEAD LOAD, PLUS CASEWORK LIVE LOAD OF 25 PSF OF SHELF AND COUNTER TOP AREA. B.1. MAXIMUM OF 1/240 THE SPAN. CODE REQUIREMENTS: PROVIDE ASSEMBLIES MEETING THE HOURLY FIRE RATINGS INDICATED AND SPECIFIED. ASSEMBLIES SHALL BEEN TESTED IN ACCORDANCE WITH ASTM E119, AND SHALL BE APPROVED BY THE LOCAL JURISDICTIONAL CODE AUTHORITIES. COORDINATE INSTALLATION OF OTHER MATERIALS THAT ARE A PART OF EACH ASSEMBLY. B.2. FIRE RATING REQUIREMENTS TAKE PRECEDENCE OVER THE CONSTRUCTION REQUIREMENTS INDICATED. IN THE EVENT OF CONFLICT, NOTIFY THE OWNER / REPRESENTATIVE, AND DO NOT BEGIN CONSTRUCTION IN THE AREA OF CONFLICT UNTIL THE CONFLICT HAS BEEN RESOLVED. B.3. PROVIDE ALL CALCULATIONS, DRAWINGS, PRODUCT DATA, AND OTHER VERIFICATION AS REQUIRED BY THE JURISDICTIONAL CODE AUTHORITY TO OBTAIN APPROVAL OF THE LIGHT GAGE METAL FRAMING INSTALLATION. C.1. LIGHT GAUGE METAL FRAMING: ASTM C645-08A; GALVANIZED; PROVIDE "C" SHAPED STUDS, U SHAPED RUNNERS, HAT AND "Z" SHAPED FURRING CHANNELS, AND OTHER SIZES AND SHAPES AS INDICATED ON THE DRAWINGS, AND AS SPECIFIED; MINIMUM 25 GAGE. C.2. COLD ROLLED CHANNELS: RUST INHIBITIVE PAINT COATING; SIZES IN ACCORDANCE WITH ASTM C754. D.2. UNLESS INDICATED OTHERWISE, INSTALL STUDS VERTICALLY AT 16 INCHES O.C, AND NOT MORE THAN 2 INCHES FROM ABUTTING CONSTRUCTION, AT EACH SIDE OF OPENINGS, AND AT CORNERS. D.3. FIT RUNNERS UNDER AND ABOVE OPENINGS; SECURE INTERMEDIATE STUDS AT SPACING OF WALL STUDS. D.4. BRACE PARTITION FRAMING SYSTEM AND MAKE RIGID. PROVIDE DIAGONAL STUD BRACING AT 8 FT ON CENTER AT ALL FRAMING THAT DOES NOT EXTEND TO STRUCTURE. D.5. INSTALL DOUBLE STUDS CONTINUOUS FROM FLOOR TO TOP TRACK AT THE JAMB OF EACH DOOR FRAME AND CASED OPENING. STUDS SHALL BE AT LEAST THE SAME GAGE AS THE ADJACENT STUDS, BUT IN NO CASE LESS THAN 20-GAGE. D.7. COORDINATE ERECTION OF STUDS WITH INSTALLATION OF SERVICE UTILITIES. ALIGN STUD WEB OPENINGS. D.8. COORDINATE ERECTION OF STUD SYSTEM WITH REQUIREMENTS OF DOOR AND WINDOW FRAMES, FIRE EXTINGUISHER CABINETS, RECESSED TOILET ACCESSORIES, ACCESS DOORS, AND OTHER CONSTRUCTION WITHIN MOUNTED PARTITION CONSTRUCTION. D.9. COORDINATE THE INSTALLATION OF FRAMING WITH THE GYPSUM BOARD INSTALLER TO ENSURE SUPPORT AT ALL BOARD EDGES. PROVIDE FRAMING IMMEDIATELY EITHER SIDE OF EXPANSION JOINTS. C.4.2. AT CONCRETE FLOORS, USE POWDER DRIVEN FASTENERS OR DRILLED IN CONCRETE ANCHORS. WHERE WALLS ARE INDICATED AS NOT BEING CONTINUOUS TO STRUCTURE ABOVE, ATTACH TOP RUNNER TO ACOUSTICAL CEILING GRID WITH SCREWS AT 24 INCHES ON CENTER. PROVIDE SPACER STRIP BETWEEN RUNNER AND CEILING SUSPENSION SYSTEM TO ALLOW REGULAR OR REVEAL EDGE ACOUSTICAL PANELS TO CLEAR PARTITION. D.6. PROVIDE MINIMUM 20 GAGE STUDS AT ALL PARTITIONS SUPPORTING CASEWORK OR COUNTER TOPS. D.12.1. AT INTERIOR PARTITIONS GREATER THAN 4 FEET IN LENGTH, AND WITH RIGID FACING MATERIAL ON ONE STUD FLANGE ONLY, PROVIDE 3/4" BRIDGING CHANNELS IN HORIZONTAL ROWS AT A MAXIMUM OF 5'-0" ON CENTER FOR THE FULL HEIGHT OF THE PARTITION. D.12.2. INTERIOR FULL HEIGHT PARTITIONS (STUDS EXTENDING FROM THE FLOOR TO THE STRUCTURE ABOVE) WITH RIGID FACING MATERIAL STOPPING 3'-0" OR MORE BELOW TOP OF STUDS: PROVIDE ONE ROW 3/4" BRIDGING CHANNEL HORIZONTALLY AT TERMINATION OF GYPSUM BOARD MATERIAL, AND ONE ADDITIONAL ROW FOR EACH 5'-0" OF EXPOSED STUDS. D.12.3. INSTALL STUD BRIDGING CHANNELS IN LONG LENGTHS, WIRE TYING AND LAPPING THE JOINTS A MINIMUM OF 12." ATTACH BRIDGING CHANNEL TO EACH STUD AS SHOWN IN MANUFACTURER'S PRINTED INSTRUCTIONS. D.11. AT NON-LOAD BEARING FULL HEIGHT PARTITIONS SUBJECT TO COMPRESSION CAUSED BY OVERHEAD STRUCTURAL DEFLECTION, CUT STUDS 1/2 INCH SHORT FROM FULL HEIGHT. DO NOT RIGIDLY CONNECT STUD TO TOP RUNNER. F.1. SECURE RUNNERS TO STRUCTURE ABOVE WITH FASTENERS AS SHOWN ON THE DRAWINGS. F.3. PROVIDE DETAILING AS INDICATED TO ALLOW FOR DEFLECTION OF BUILDING STRUCTURE. G.1. PROVIDE USG DGLW SUSPENDED GYPSUM WALL BOARD CEILING SYSTEM, INSTALLED PER ASTM C363. G.2. SUSPEND CEILING FROM OVERHEAD CONCRETE DECK AND STRUCTURAL ELEMENTS ONLY PER L.L. REQUIREMENTS. DO NOT SUPPORT FROM ANY ELECTRICAL, HVAC, PLUMBING, OR SPRINKLER SYSTEM COMPONENTS. WHERE OVERHEAD OBSTRUCTIONS PREVENT THE REGULAR SPACING OF HANGERS, PROVIDE SECONDARY CARRYING MEMBERS FOR INDIRECT SUPPORT OF THE SUSPENSION SYSTEM, OR REINFORCE THE NEAREST ADJACENT HANGERS AND RELATED FRAMING COMPONENTS AS REQUIRED TO SPAN THE REQUIRED DISTANCE. G.3. SPACE CARRYING CHANNELS 4 FEET ON CENTER WITH ALL SPLICES LAPPED 12 INCHES AND TIED. G.4. SUPPORT COLD ROLLED CARRYING CHANNELS WITH HANGER WIRES SPACED AT 4 FEET ON CENTER FOR GYPSUM BOARD CEILINGS. LOOP HANGER WIRE AROUND SUPPORT ELEMENT AND TIGHTLY WRAP AROUND VERTICAL WIRE 3 TIMES; CUT OFF NEATLY.G.5. SPACE FURRING CHANNELS 16" O.C. WITH ALL SPLICES LAPPED 12", MINIMUM AND TIED; CLIP OR SADDLE TIE TO RUNNER CHANNELS WITH 16GA. TIE WIRE. H.1. INSTALL MEMBERS TO PROVIDE SURFACE PLANE WITH MAXIMUM VARIATION OF 1/8 INCH IN 10 FEET IN ANY DIRECTION. C.1. INSTALLATION STANDARD: UNLESS SPECIFIED OTHERWISE, PERFORM WORK IN ACCORDANCE WITH GYPSUM ASSOCIATION 216, "RECOMMENDED SPECIFICATIONS FOR THE APPLICATION AND FINISHING OF GYPSUM WALLBOARD, INCLUDING CONTROL JOINTS PER MANUFACTURER RECOMMENDATIONS." C.2. INSTALL WATER RESISTANT BOARD AS A SUBSTRATE FOR SURFACES SCHEDULED TO RECEIVE BONDED FINISHES IN RESTROOMS. C.4.1. INSTALL SINGLE LAYER OF 5/8" BOARD OR MULTIPLE LAYERS OF THINNER BOARD AT INSTALLER'S OPTION. C.4.2. FOR THICKER BOARD AND TIGHTER RADII, DAMPEN BOARD, BLOCK TO THE REQUIRED UNIFORM RADIUS, AND ALLOW TO SET FOR APPROX. ONE HOUR PRIOR TO INSTALL. C.4.3. FOR RADII TIGHTER THAN 46" DAMPEN BOARD WITH 10 TO 15 OZ OF WATER PER SIDE AND ALLOW TO SOAK FOR 15 MINUTES PRIOR TO INSTALLATION. COMPLY WITH MANUFACTURER'S INSTRUCTIONS FOR ATTACHMENT TO FRAMING. C.4.4. INSTALL BOARD WITH LONG DIRECTION PERPENDICULAR TO AXIS OF CURVE RADIUS. C.4.5. INSTALL SECOND LAYER IN ACCORDANCE WITH SPECIFICATIONS FOR "MULTIPLE LAYER APPLICATIONS." C.4.6. SELECT METHODS TO PRODUCE A UNIFORM RADIUS WITH SMOOTH TRANSITIONS AT JOINTS. INSTALL BOARD TIGHT TO FRAMING. D.2. WHERE NECESSARY TO SAND, DO SO WITHOUT DAMAGING THE FACE OF THE GYPSUM BOARD. D.3.1. LEVEL 5: PROVIDE AT PUBLIC AREAS, INCLUDING SURFACES TO RECEIVE EIFS FINISHES. D.4. GYPSUM BOARD SURFACES SHALL FORM A SMOOTH SURFACE FREE OF RIDGES, JOINT MARKS, FASTENER DEPRESSIONS, AND JOINT FILLER LINES. TAPERED BOARD JOINTS SHALL BE TAPED, FILLED, AND FEATHERED TO 12 INCHES EITHER SIDE OF THE JOINT. NON-TAPERED BOARD JOINTS SHALL BE TAPED, FILLED, AND FEATHERED TO 18 INCHES EITHER SIDE OF THE JOINT. D.5. FINISH EXISTING GYPSUM BOARD SURFACES TO REMAIN TO MATCH NEW GYPSUM BOARD SURFACES. B.1.1. 5/8 INCH THICK UNLESS NOTED OTHERWISE; PROVIDE TYPE X IN FIRE RATED PARTITIONS. B.2.1. TRIM: CONCEALED FLANGE CRIMP-ON OR TAPE-ON TYPE; METAL OR PVC AT CONTRACTOR'S OPTION; GA 216. B.2.2. JOINT COMPOUND, TAPE, AND FINISHING COMPOUND: ASTM C475 / C475M - 02 AND GA 216; USE SETTING TYPE JOINT COMPOUND AT WATER RESISTANT BOARD. B.2.3. GWB PRIME COAT: USG / BEADEX MANUFACTURING COMPANY (AUBURN, WA; 253 931 6600) "PRECOAT." E. APPLY PRIME COAT TO ALL GWB SURFACES SCHEDULED FOR LEVEL 4 AND LEVEL 5 FINISHES. SUPPLY AND INSTALL MOBILFLEX SLIDING GRILLE IMPACT MODEL - “POLYCARBONATE PANELS” 1.01 PART ONE- SUMMARY: SYSTEM IS PROVIDED AND INSTALLED BY GENERAL CONTRACTOR A. WORK INCLUDED: SYSTEM IS PROVIDED AND INSTALLED BY GENERAL CONTRACTOR B. SUBMITTALS: NONE C. QUALITY ASSURANCE 1. PROVIDE COMPONENTS FROM A SINGLE MANUFACTURER WITH RESOURCES TO PROVIDE CONSISTENT QUALITY IN APPEARANCE. FIELD MEASURE BEFORE FABRICATION. USE MANUFACTURER APPROVED INSTALLERS. 2.01 PART TWO- PRODUCTS D. MANUFACTURER: a. IN THE UNITED STATES: MOBILFLEX, INC., AYMERIC LACHAUT -800-216-3539, FAX: 800-254-3538 2.02 CURTAIN SPECIFICATIONS: CURTAIN DESIGN: IMPACT MODEL 2.03 LOCKING: REFER TO SHEET A2.2 FOR LOCKING REQUIREMENTS PART THREE EXECUTION 3.01 INSPECTION: 1. VERIFY THAT THE FOLDING SECURITY CLOSURE SYSTEM WILL NOT DISRUPT OTHER TRADES. THE DOOR INSTALLER SHALL VERIFY THAT THE INSTALLATION AREA IS DRY, CLEAN, AND FREE OF FOREIGN MATTER. CHECK AS-BUILD CONDITIONS AND VERIFY THE OPENING DIMENSIONS PRIOR TO INSTALLATION. REPORT IN WRITING ANY CONDITIONS DETRIMENTAL TO THE PROPER FUNCTIONING OF THE FOLDING SECURITY CLOSURE SYSTEM. THE INSTALLATION SHALL PROCEED ONCE ANY UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN ACCORDANCE TO THE MANUFACTURER'S RECOMMENDATIONS. VERIFY DIMENSIONS OF OPENING PRIOR TO INSTALLATION 3.02 INSTALLATION OF FOLDING SECURITY CLOSURE SYSTEM :1. INSTALLATION SHALL BE BY AN INSTALLER APPROVED AND TRAINED BY THE MANUFACTURER IN STRICT ACCORDANCE WITH INSTALLATION GUIDE. 2. EXPLAIN AND REVIEW THE CORRECT LOCKING, OPERATION AND MAINTENANCE OF THE FOLDING SECURITY CLOSURE SYSTEM. END OF SECTION 08350 THE TOP AND BOTTOM OF EACH SECTION IS FITTED WITH AN ALUMINUM PANEL 4” HIGH. THIS PANEL CONSISTS OF AN ALUMINUM EXTRUSION 1/16” THICK AND COMPOSED OF MODULES WITH A 15° ANGLE BETWEEN THEM TO FACILITATE THE OPERATION OF THE CLOSURE. THE CURTAIN IS CONSTRUCTED OF 6” WIDE MODULES LINKED TOGETHER BY A CONTINUOUS ALUMINUM HINGE. THESE HINGES WILL HOLD "SELF-EXTINGUISHING" COPOLYESTER PANELS 5-1/2” WIDE AND 1/16” THICK. EACH PANEL IS ENTIRELY RECESSED IN THE ALUMINUM HINGE THROUGHOUT ITS FULL HEIGHT. 2.04 TRACK CURTAIN SHALL BE HUNG FROM AN OVERHEAD TRACK 1-5/16" BY 1-9/16" HIGH. TRACK TEMPERED ALUMINUM ALLOY 6351-T6 AND FINISHED BLACK. REFER TO SHEET A2.2 FOR ADDITIONAL INFORMATION. 2.05 STACKING - REFER TO STOREFRONT SHEETS FOR STACKING LOCATION 2.06 FINISH FINISH SHALL BE STANDARD CLEAR ANODIZED CLEAN AND ADJUST CLOSURE TO ENSURE SMOOTH OPERATION. A. REFERENCES: A.1. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM): A.1.1. C635/C635M-07 - METAL SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY-IN PANEL CEILINGS. A.1.2. C636/C636M-08 - RECOMMENDED PRACTICE FOR THE INSTALLATION OF METAL CEILING SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY-IN PANELS. B. PRODUCTS: AS INDICATED ON THE DRAWINGS, C. INSTALLATION: C.1. INSTALL SYSTEM IN ACCORDANCE WITH ASTM C636 AND THE REQUIREMENTS OF THE JURISDICTIONAL CODE AUTHORITIES. C.2. INSTALL GRID TO PRODUCE FINISHED CEILING TRUE TO LINES AND LEVELS INDICATED, WITHIN THE SPECIFIED TOLERANCES. C.3. INSTALL SUSPENSION SYSTEMS IN A MANNER TO SUPPORT ALL SUPERIMPOSED LOADS, WITH MAXIMUM PERMISSIBLE DEFLECTION OF 1/270 OF SPAN. C.4. HANG SYSTEM INDEPENDENT OF WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT. WHERE DUCTS OR OTHER EQUIPMENT PREVENT THE REGULAR SPACING OF HANGERS, PROVIDE SECONDARY CARRYING MEMBERS FOR INDIRECT SUPPORT OF THE SUSPENSIONS SYSTEM, OR REINFORCE THE NEAREST ADJACENT HANGERS AND RELATED CARRYING CHANNELS AS REQUIRED TO SPAN THE REQUIRED DISTANCE. C.5. CENTER SYSTEM ON ROOM AXIS ACCORDING TO REFLECTED CEILING PLANS. C.6. PROVIDE ALL ANCHORS REQUIRED FOR THE INSTALLATION OF THE CEILING SYSTEM. DO NOT ANCHOR SYSTEM IN ANY MANNER THAT MIGHT CAUSE DAMAGE TO THE STRUCTURAL SYSTEM. C.7. INSTALL EDGE MOLDING AT INTERSECTION OF CEILING AND VERTICAL SURFACES, USING LONGEST PRACTICAL LENGTHS. MITER CORNERS. PROVIDE EDGE MOLDINGS AT JUNCTIONS WITH OTHER INTERRUPTIONS. FABRICATE EDGE MOLDINGS TO FIT THE SURFACES ENCOUNTERED. C.8. FIT ACOUSTIC LAY-IN PANELS IN PLACE, FREE FROM DAMAGED EDGES OR OTHER DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION. FIT BORDER UNITS NEATLY AGAINST ABUTTING SURFACES. SCRIBE AND MILL RECESSED TEGULAR EDGE INTO PARTIAL BORDER UNITS SUPPORTED AT EDGE BY WALL MOLDING. C.9. HOLD-DOWN CLIPS: INSTALL HOLD-DOWN CLIPS AT PANELS WITHIN 20 FEET OF AN EXTERIOR DOOR. C.10. TOLERANCES: C.10.1. VARIATION FORM FLAT AND LEVEL SURFACE: 1/8 INCH IN 10 FEET. C.10.2. VARIATION FROM PLUMB OF GRID MEMBERS CAUSED BY ECCENTRIC LOADS: TWO DEGREES MAXIMUM. PART 1 - GENERAL RELATED DOCUMENTS: DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 SPECIFICATION SECTIONS, APPLY TO WORK OF THIS SECTION. DESCRIPTION OF WORK: EXTENT OF LUXURY VINYL TILE FLOORING AND ACCESSORIES IS SHOWN ON DRAWINGS AND IN MATERIAL AND ROOM FINISH SCHEDULES. QUALITY ASSURANCE: MANUFACTURER: PROVIDE EACH TYPE OF LUXURY VINYL TILE AND ACCESSORIES AS PRODUCED BY A SINGLE MANUFACTURER, INCLUDING RECOMMENDED PRIMERS, ADHESIVES, SEALANTS AND LEVELING COMPOUNDS. FIRE TEST PERFORMANCE: PROVIDE LUXURY VINYL TILE FLOORING WHICH COMPLIES WITH THE FLOORING FIRE TEST PERFORMANCE CRITERIA AS DETERMINED BY AN INDEPENDENT TESTING LABORATORY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. FLAME SPREAD: > 0.45 WATTS/CM2 CLASS I - ASTM E-648 SMOKE DENSITY: < 450 PER ASTM E 662 SUBMITTALS: PRODUCT DATA: SUBMIT MANUFACTURER'S TECHNICAL DATA FOR EACH TYPE OF LUXURY VINYL TILE AND ACCESSORY. SAMPLES FOR INITIAL SELECTION PURPOSES: SUBMIT MANUFACTURER'S STANDARD COLOR CHARTS IN FORM OF ACTUAL SECTIONS OF LUXURY VINYL TILE, INCLUDING ACCESSORIES, SHOWING FULL RANGE OF COLORS AND PATTERNS AVAILABLE, FOR EACH TYPE OF LUXURY VINYL TILE REQUIRED. SAMPLES FOR VERIFICATION PURPOSES: SUBMIT THE FOLLOWING SAMPLES OF EACH TYPE, COLOR AND PATTERN OF LUXURY VINYL TILE REQUIRED, SHOWING FULL RANGE OF COLOR AND PATTERN VARIATIONS. FULL SIZE TILE SAMPLES. 6” LONG SAMPLES OF RESILIENT BASES, INCLUDING PREFORMED CORNERS. 6” LONG SAMPLES OF RESILIENT EDGE STRIPS. 2 ½” LONG SAMPLES OF LUXURY VINYL TILE ACCESSORIES. OTHER MATERIALS, SUCH AS STAIR TREAD UNITS, ETC., AS REQUIRED. CERTIFICATION FOR FIRE TEST PERFORMANCE: SUBMIT CERTIFICATION FROM INDEPENDENT TESTING LABORATORY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION THAT LUXURY VINYL TILE COMPLIES WITH FIRE TEST PERFORMANCE REQUIREMENTS. BOND AND MOISTURE TESTS: SUBMIT LOCATION DIAGRAMS AND RESULTS. IT IS ESSENTIAL THAT MOISTURE TESTS BE TAKEN ON ALL CONCRETE FLOORS REGARDLESS OF THE AGE OR GRADE LEVEL. CHECK MOISTURE CONTENT DOES NOT EXCEED 2.5% BY WEIGHT (CALCIUM CARBIDE TEST METHOD) OR MOISTURE EMISSIONS DO NOT EXCEED 3 LBS. WATER/24 HOURS/1000 SQ. FT. (CALCIUM CHLORIDE TEST METHOD) BY CONDUCTING MOISTURE TESTS, AROUND THE PERIMETER OF THE ROOM, AT COLUMNS AND WHERE MOISTURE MAY BE EVIDENT. CALCIUM CHLORIDE TESTS AND/OR CALCIUM CARBIDE TESTS MUST BE DONE IN ACCORDANCE WITH ASTM F-1869 AND TO INSTRUCTIONS. IT IS THE RESPONSIBILITY OF THE OWNER OR HIS AGENT TO PROVIDE ADEQUATE MOISTURE TESTING BY AN INDEPENDENT AGENCY ACCEPTABLE TO THE FLOOR COVERING MANUFACTURER FOR PRODUCTS SPECIFIED WITHIN THIS DOCUMENT MAINTENANCE INSTRUCTION: SUBMIT TWO COPIES OF MANUFACTURER RECOMMENDED MAINTENANCE PRACTICES FOR EACH TYPE OF LUXURY VINYL TILE FLOORING AND ACCESSORY REQUIRED. PROJECT CONDITIONS: MAINTAIN MINIMUM TEMPERATURE AS INSTRUCTED BY MATERIAL MANUFACTURERS BUT NOT LESS THAN 65 F (18 C) IN SPACES TO RECEIVE LUXURY VINYL TILE FOR AT LEAST 48 HOURS PRIOR TO INSTALLATION, DURING INSTALLATION AND FOR NOT LESS THAN 48 HOURS AFTER INSTALLATION. STORE LUXURY VINYL TILE MATERIALS IN SPACES WHERE THEY WILL BE INSTALLED FOR AT LEAST 48 HOURS BEFORE BEGINNING INSTALLATION. SUBSEQUENTLY, MAINTAIN MINIMUM TEMPERATURE OF 55 F (13 C) IN AREAS WHERE WORK IS COMPLETED. INSTALL LUXURY VINYL TILE AND ACCESSORIES AFTER OTHER FINISHING OPERATIONS, INCLUDING PAINTING, HAVE BEEN COMPLETED. DO NOT INSTALL LUXURY VINYL TILE OVER CONCRETE SLABS UNTIL THE LATTER HAVE BEEN CURED AND ARE SUFFICIENTLY DRY TO ACHIEVE BOND WITH ADHESIVE AS DETERMINED BY THE LUXURY VINYL TILE MANUFACTURER'S RECOMMENDED BOND AND MOISTURE TEST. DO NOT TAKE TESTS LATER THAN TEN DAYS PRIOR TO SCHEDULED INSTALLATION. NOTIFY ARCHITECT IMMEDIATELY OF UNSATISFACTORY CONDITIONS. PART 2 - PRODUCTS DISTRIBUTOR: ECORE COMMERCIAL LTD. 119 S TREE DRIVE LANCASTER, PA 17603 PHONE 1-888-359-5466 - 717-299-5035 FAX 1-717-394-1937 PRODUCTS ARE AVAILABLE THROUGH CONTRACT FLOORING DEALERS. LUXURY VINYL TILE COLORS AND PATTERNS: PROVIDE COLOR AND PATTERNS AS INDICATED, OR IF NOT INDICATED IN MATERIALS SCHEDULE AND/OR DRAWINGS AS SELECTED BY ARCHITECT FROM MANUFACTURER'S STANDARDS. GAUGE: 5.0MM WEAR LAYER: .5MM (30 MILS) STANDARD: COMPLY W/ASTM F 1066, ASTM E648, AND ASTM E662 EDGE TREATMENT: SQUARE ONLY, NOT BEVELED PERFORMANCE/GENERAL ASTM F-1066 FLAME SPREAD ASTM E648 >0.45 WATTS/CM2 CLASS 1 SMOKE DENSITY ASTM E662 < 450 PASS STATIC LOAD ASTM F970(M) - 900 PSI COEFFICIENT OF FRICTION ASTM D2047 >0.5 ABRASION RESISTANCE ASTM D3884-09 PASS RESISTANCE TO CHEMICALS ASTM F925-02 NO CHANGE AFTER 24 HOURS DIMENSIONAL STABILITY ASTM F2199-09 PASS PART 3 - EXECUTION INSPECTION: REQUIRE INSTALLER TO INSPECT SUBFLOOR SURFACES TO DETERMINE THAT THEY ARE SATISFACTORY. A SATISFACTORY SUBFLOOR SURFACE IS DEFINED AS ONE THAT IS SMOOTH AND FREE FROM CRACKS, HOLES, RIDGES, OR COATINGS PREVENTING ADHESIVE BOND AND OTHER DEFECTS IMPAIRING PERFORMANCE OR APPEARANCE. CONCRETE SUBFLOORS: VERIFY THAT CONCRETE SLABS COMPLY WITH ASTM F710 AND THE FOLLOWING: SLAB SUBSTRATES ARE DRY AND FREE OF CURING COMPOUNDS, SEALERS, HARDENERS AND OTHER MATERIALS THAT MAY INTERFERE WITH ADHESIVE BOND. DETERMINE ADHESION AND DRYNESS CHARACTERISTICS BY PERFORMING BOND AND MOISTURE TESTS RECOMMENDED BY FLOORING MANUFACTURER. DO NOT ALLOW LUXURY VINYL TILE WORK TO PROCEED UNTIL SUBFLOOR SURFACES ARE SATISFACTORY. PREPARATION: PREPARE SUBFLOOR SURFACE AS FOLLOWS: INSPECTION OF EXISTING SUB--FLOOR: A SOLID, DRY, CLEAN SUB-FLOOR IS REQUIRED FOR THE INSTALLATION OF ALL POLYFLOR MATERIALS. USE CEMENTITIOUS LEVELING AND PATCHING COMPOUNDS AS RECOMMENDED BY LUXURY VINYL TILE MANUFACTURER FOR FILLING SMALL CRACKS, HOLES AND DEPRESSIONS AND LEVELING SUBFLOORS. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR LEVELING NEW OR EXISTING FLOORS WHOSE SURFACE VARIES UP TO 5/16”. NOTIFY OWNER, ARCHITECT AND GENERAL CONTRACTOR IN WRITING WHERE SUBSTRATE VARIES MORE THAN ABOVE BEFORE PROCEEDING WITH THE WORK. GYPSUM BASED LEVELING COMPOUNDS WILL NOT BE ACCEPTED. USE CEMENTITIOUS LEVELING AND PATCHING COMPOUNDS AS RECOMMENDED BY LUXURY VINYL TILE MANUFACTURER FOR FILLING SMALL CRACKS, HOLES AND DEPRESSION IN SUBFLOORS. REMOVE COATINGS FROM SUBFLOOR SURFACES THAT WOULD PREVENT ADHESIVE BOND, INCLUDING CURING COMPOUNDS INCOMPATIBLE WITH LUXURY VINYL TILE ADHESIVES, PAINTS, OILS, WAXES AND SEALERS. BROOM CLEAN OR VACUUM SURFACES TO BE COVERED, AND INSPECT SUBFLOOR. INSTALLATION INSTALLATION, GENERAL: INSTALLER VERIFICATION: ALL POLYFLOR MATERIALS SHOULD BE INSTALLED BY A PROFESSIONAL FLOORING MECHANIC, PREFERABLY ONE WHO HAS ATTENDED AN INSTALLATION CLINIC OR A MASTER MECHANIC TRAINING SEMINAR. (CONTINUED ON NEXT PAGE) RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt SPECIFICATIONS G503 SECTION 09651 RESILIENT FLOORING SECTION 09658 RESILIENT BASE SECTION 09720 WALL COVERINGS SECTION 09775 FIBERGLASS REINFORCED PLASTIC (FRP) PANEL WALL COVERING SECTION 09820 ACOUSTICAL INSULATION AND SEALANTS DIVISION 10:SPECIALTIES SECTION 10400 SIGNAGE SECTION 10810 TOILET ACCESSORIES SECTION 10999 MISCELLANEOUSSECTION 09900 PAINTING DIVISION 11 - EQUIPMENT DIVISION 12 - FURNISHINGS DIVISION 13 - SPECIAL CONSTRUCTION DIVISION 14 - CONVEYING SYSTEMS DIVISION 15 - MECHANICAL DIVISION 16 - ELECTRICAL A. MATERIALS: AS INDICATED ON THE DRAWINGS, NO SUBSTITUTIONS ALLOWED. A.1. RESILIENT FLOORING: A.1.1. VINYL COMPOSITION TILE (VCT): AS SCHEDULED ON THE DRAWINGS. A.2. LATEX UNDERLAYMENT: WHITE PREMIX LATEX FILLER, MIXED WITH WATER TO PRODUCE A CEMENTITIOUS PASTE. A.3. PRIMERS AND ADHESIVES: TYPES AS RECOMMENDED BY RESILIENT FLOORING AND BASE MANUFACTURERS FOR SPECIFIC APPLICATION. A.4. TRANSITION STRIPS: A.4.1. AS DETAILED ON SHEET A2.2 B. PREPARATION: INSTALL SUBFLOOR FILLER TO FILL LOW SPOTS, CRACKS, CONSTRUCTION JOINTS, HOLES AND OTHER DEFECTS, AND AS REQUIRED TO ADJUST LEVEL TO MEET ADJACENT FINISHES. FEATHER TO MAXIMUM SLOPE OF 1/8 INCH IN 3 FEET; FLOAT TO SMOOTH, FLAT, HARD SURFACE. PROHIBIT TRAFFIC OVER FILLER. C. RESILIENT FLOORING INSTALLATION C.1. INSTALL RESILIENT FLOORING WHERE SCHEDULED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. C.2. UNLESS INDICATED OTHERWISE, INSTALL RESILIENT FLOORING WITH JOINTS AND SEAMS PARALLEL TO BUILDING LINES. C.3. TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR AT DOOR OPENINGS WHERE ADJACENT FLOOR FINISH IS DISSIMILAR, AND WHERE NO THRESHOLD IS INDICATED. C.4. INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES WHERE FLOORING TERMINATES. C.5. SCRIBE FLOORING TO WALLS, COLUMNS, CABINETS, FLOOR OUTLETS AND OTHER APPURTENANCES TO PRODUCE TIGHT JOINTS. C.6. CLEAN SUBSTRATE. SPREAD CEMENT EVENLY IN QUANTITY RECOMMENDED BY MANUFACTURER TO ENSURE ADHESION OVER ENTIRE AREA OF INSTALLATION. SPREAD ONLY ENOUGH ADHESIVE TO PERMIT INSTALLATION OF FLOORING BEFORE INITIAL SET. C.7. SET FLOORING IN PLACE; PRESS WITH HEAVY ROLLER TO ENSURE FULL ADHESION. D. SPECIAL REQUIREMENTS FOR RESILIENT TILE: D.1. OPEN FLOOR TILE CARTONS, ENOUGH TO COVER EACH AREA, AND MIX TILE TO ENSURE SHADE VARIATIONS DO NOT OCCUR WITHIN ANY ONE AREA. D.2. INSTALL TILES AS INDICATED ON THE DRAWINGS. D.3. INSTALL WITH MINIMUM TILE WIDTH 1/2 FULL SIZE AT ROOM OR AREA PERIMETER, UNLESS INDICATED OTHERWISE. D.4. ARRANGE TO SQUARE GRID PATTERN WITH ALL JOINTS ALIGNED, WITH PATTERN GRAIN ALTERNATING WITH ADJACENT UNIT TO PRODUCE BASKET WEAVE PATTERN WITH PATTERN GRAIN PARALLEL FOR ALL UNITS AND PARALLEL TO THE LENGTH OF THE ROOM. E. SEAL JOINT BETWEEN FLOORING AND ADJACENT MATERIALS AT RESTROOMS, BATHROOMS, BREAKROOMS, AND OTHER MOIST AREAS WITH CLEAR SILICONE SEALANT. F. SPECIAL PROTECTION REQUIREMENTS FOR INTERIOR RESILIENT TILE SURFACES: F.1. AREAS SUBJECT ONLY TO FOOT TRAFFIC: LAY DOWN NON-STAINING CURING PAPER LAPPED AND SEALED AT JOINTS AND EDGES WITH NASHUA BRAND DUCT TAPE. DO NOT USE POLYETHYLENE OR PRODUCTS CONTAINING BITUMINOUS MATERIALS. F.2. AREAS SUBJECT TO ROLLING TRUCKS, DOLLIES AND OTHER EQUIPMENT: IN ADDITION TO THE ABOVE, SUCH AREAS SHALL BE FURTHER PROTECTED BY CONTINUOUS PLYWOOD OR HARDBOARD RUNWAYS. COORDINATE DESIGNATION OF SUCH AREAS. STRIP AND WAX VCT. A. MATERIALS: AS INDICATED ON THE DRAWINGS, NO SUBSTITUTIONS ALLOWED. A.1. RUBBER BASE: AS SCHEDULED ON THE DRAWINGS. A.2. PROVIDE ROLL GOODS ONLY. PRIMERS AND ADHESIVES: TYPES AS RECOMMENDED BY RESILIENT BASE MANUFACTURER FOR SPECIFIC APPLICATION. B. INSTALLATION: B.1. ADHESIVE INSTALL BASE MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ADHERE TIGHTLY TO WALL AND FLOOR SURFACES. B.2. USE MANUFACTURER'S LONGEST LENGTHS. WHERE CUTTING IS NECESSARY, MAINTAIN MINIMUM MEASUREMENT OF 18 INCHES BETWEEN JOINTS. B.3. MITER OR COPE INSIDE CORNERS FOR ACCURATE FIT. B.4. INSTALL BASE TO WALLS AND COLUMNS IN ALL AREAS WHERE RUBBER BASE IS SCHEDULED. B.5. COORDINATE WITH OWNER'S CASEWORK VENDOR AND PROVIDE BASE TO WOOD CASEWORK TOE KICKS WHERE REQUIRED. B.6. SCORE BACK OF BASE MATERIAL WITH GROOVING TOOL, AT ALL OUTSIDE CORNERS; MAINTAIN MINIMUM LEG LENGTH 18 INCHES WHERE WALL LENGTH PERMITS. MOUNT BASE SO THAT SCORED GROOVE IS ACCURATELY ALIGNED WITH CORNER, AND WITH BASE TIGHTLY ADHERED TO WALL AT BOTH SIDES OF CORNER, WITH NO VISIBLE GAPS AT TOP OF BASE. WHERE COVE BASE IS FORMED AROUND OUTSIDE CORNERS, STRETCH TOE OF COVE FOR SMOOTH TRANSITION AROUND CORNER, WITH TOE IN UNIFORM CONTACT WITH THE FINISH FLOORING. B.7. SCRIBE AND FIT TO DOOR FRAMES AND OTHER OBSTRUCTIONS. B.8. INSTALL STRAIGHT AND LEVEL TO VARIATION OF PLUS OR MINUS 1/8 INCH OVER 10 FEET. B.9. COORDINATE INSTALLATION OF BASE WITH WORK OF SECTION 09680. B.10. FIT JOINTS TIGHT AND VERTICAL. C. CLEANING C.1. REMOVE EXCESS ADHESIVE FROM FLOOR, BASE, AND WALL SURFACES WITHOUT DAMAGE. C.2. CLEAN BASE AND FLOOR IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. A. MATERIALS: A.1. WALL COVERINGS: AS SCHEDULED ON THE DRAWINGS. A.2. ADHESIVES: AS RECOMMENDED BY THE WALL COVERING MANUFACTURER. A.3. ALL WALL COVERINGS SHALL HAVE A MAXIMUM FLAME SPREAD OF 75 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84. FIRE RETARDANT TREAT ALL NONCONFORMING WALL COVERING. TREATMENT SHALL NOT ALTER THE APPEARANCE OF THE FABRIC. B. PREPARATION: B.1. REMOVE ELECTRICAL OUTLET AND SWITCH PLATES, MECHANICAL DIFFUSERS, ESCUTCHEONS, REGISTERS, SURFACE HARDWARE, FITTINGS, AND FASTENINGS PRIOR TO STARTING WORK; STORE DURING AND REPLACE AFTER WORK. B.2. AT EXISTING PAINTED SURFACES, EVENLY ROUGHEN WITH A MEDIUM GRIT GARNET PAPER, WASH WITH TSP, WIPE CLEAR WATER, ALLOW TO DRY, AND SIZE WITH WALL COVERING ADHESIVE. B.3. TEST SUBSTRATES WITH A SUITABLE MOISTURE METER TO VERIFY THAT THE MOISTURE CONTENT DOES NOT EXCEED 4% C. INSTALLATION - WALL COVERING ON GYPSUM WALL BOARD: C.1. MIX AND APPLY ADHESIVES IN STRICT ACCORDANCE WITH THE ADHESIVE MANUFACTURER'S DIRECTIONS FOR THE TYPE OF MATERIAL BEING APPLIED. C.2. INSTALL WALL COVERING SECURE, SMOOTH, CLEAN, AND WITHOUT WRINKLES, GAPS OR OVERLAPS. C.3. EXTEND WALL COVERING CONTINUOUSLY BEHIND SUCH ITEMS AS MIRRORS, AND OTHER ITEMS WHICH ARE CLOSE TO BUT NOT TOUCHING WALLS. C.4. INSTALL WALL COVERING WHERE SCHEDULED IN STRICT ACCORDANCE WITH THE WALL COVERING MANUFACTURER'S RECOMMENDATIONS. C.5. PROVIDE DOUBLE-CUT SEAMS ON NONMATCH PATTERNS; BUTT SEAMS ON MATCH PATTERNS. E. EXCESS YARDAGE: E.1. NOTIFY DESIGNATED OWNER'S REPRESENTATIVE AT THE SITE PRIOR TO REMOVING EXCESS YARDAGE FROM THE JOB. THE OWNER'S REPRESENTATIVE WILL SELECT THE MATERIALS WHICH ARE TO BE RETAINED BY THE OWNER. E.2. CAREFULLY WRAP THE EXCESS YARDAGE SELECTED TO BE RETAINED. DELIVER TO A LOCATION ON SITE AS DIRECTED BY THE OWNER. REMOVE REMAINDER FROM THE SITE AND DISPOSE OF LEGALLY. A. SUMMARY: FIBERGLASS REINFORCED PLASTIC PANEL (FRP) WALL COVERING. B. REFERENCES: AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM): E84 - TEST METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS C. DELIVERY, STORAGE AND HANDLING: COMPLY WITH REQUIREMENTS OF SECTION 01600. D. ENVIRONMENTAL CONDITIONS D.1. MAINTAIN A MINIMUM TEMPERATURE OF 60 DEGREES F AND RELATIVE HUMIDITY AS PRESCRIBED BY THE ADHESIVE MANUFACTURER, DURING INSTALLATION, AND UNTIL INSTALLED ADHESIVE IS FULLY CURED. D.2. ALLOW NO CONTAINERS OF ADHESIVE TO BE OPENED UNTIL ALL POTENTIAL SOURCES OF FLAME OR SPARK HAVE BEEN SHUT DOWN OR EXTINGUISHED AND UNTIL WARNINGS AGAINST THEIR IGNITION DURING ADHESIVE APPLICATION HAVE BEEN POSTED. D.3. PROVIDE VENTILATION TO DISPERSE FUMES DURING APPLICATION OF SOLVENT-BASED ADHESIVE. E. PANEL SYSTEM COMPONENTS: E.1. PANEL MATERIAL: E.1.1. MANUFACTURER/TYPE: ONE OF THE FOLLOWING. E.1.1.1. MARLITE BRAND CLASS I/A FIRE RATED FRP BY MARLITE (DOVER, OH 330/343-6621); COLOR AS SCHEDULED IN THE FINISH LEGEND. E.1.1.2. FIRE-X GLASBORD WITH SURFASEAL, BY CRANE COMPOSITES (815/467-8600); COLOR AS SCHEDULED IN THE FINISH LEGEND. E.1.1.3. "77136 STRUCTOGLAS FIRE RETARDANT WALL & CEILING PANELS" BY SEQUENTIA INC. (GRAND JUNCTION TN; 815 467 8600; 800 435 0080); COLOR AS SCHEDULED IN THE FINISH LEGEND. E.1.2. PANEL TYPE: FIBERGLASS REINFORCED POLYESTER PANELS, WITH EMBOSSED TEXTURED FACE. E.1.3. THICKNESS: 3/32 INCH. E.1.4. SIZE: 48 INCHES X LENGTH REQUIRED FOR CONDITIONS INDICATED. E.1.5. FIRE RATING: MAXIMUM 25/450 FLAME SPREAD / SMOKE DEVELOPED IN ACCORDANCE WITH ASTM E84. E.2. MOLDINGS: MANUFACTURER'S STANDARD PVC CAP, CORNER, AND DIVISION MOLDINGS; COLOR TO MATCH PANELS. OMIT BOTTOM TRIM WHERE PANEL ABUTS FLASH COVED BASE. E.3. PANEL AND MOLDING INSTALLATION ADHESIVE: E.3.1. ONE OF THE FOLLOWING: E.3.1.1. MARLITE BRAND C-551 CONSTRUCTION ADHESIVE. E.3.1.2. 444 NONFLAMMABLE FRP PANEL ADHESIVE BY W. W. HENRY COMPANY. E.3.1.3. "4054 TITEBOND SOLVENT FREE FAST GRAB FRP ADHESIVE" BY NATIONAL NAIL, NATIONALNAIL.COM E.3.2. FURNISH ADHESIVE SPREADERS WITH 3/16 INCH V-NOTCHES, 5/16 INCH APART FOR APPLICATION OF ADHESIVE TO PANELS. E.4. SEALANT: FLEXIBLE WATERPROOF SEALANT FOR BEDDING PANEL EDGES, MARLITE BRAND SILICONE SEALANT MS 251 BY MARLITE, OR SILICONE SEALANT S255C BY CRANE COMPOSITES. F. CONDITION OF SURFACES F.1. SUBSTRATE: VERIFY THAT DRYWALL SUBSTRATE IS CLEAN, DRY, SOLID, STRAIGHT, AND FREE FROM PROJECTIONS. F.3. DO NOT START WORK UNTIL OTHER WORK REQUIRING PENETRATION OF WALL COVERING HAS BEEN COMPLETED, OR ACCURATELY LOCATED. F.4. COMMENCEMENT OF PLASTIC PANELING WALL COVERING WORK CONSTITUTES INSTALLER'S ACCEPTANCE OF THE SUBSTRATE. G. CUTTING AND FITTING G.1. CUT PANELS ACCURATELY TO SIZE WITH PROPER ALLOWANCE FOR EXPANSION AND MOLDINGS. G.2. SAND OR FILE ALL EDGES SMOOTH WITHOUT CHIPPING. G.3. CUT OPENINGS FOR PENETRATIONS IN ACCURATE LOCATION WITH APPROXIMATE 1/8-INCH CLEARANCE AROUND PENETRATIONS. H. INSTALLATION H.2. CUT TOP CAP AND DIVISION OR CORNER MOLDINGS TO SHAPE, WITH EDGES TRIMMED TO FIT TO ADJACENT MOLDINGS. H.3. APPLY SEALANT INTO INSTALLED MOLDINGS IN SEQUENCE WITH PANEL INSTALLATION. H.4. APPLY ADHESIVE TO BACKS OF PANELS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. H.5. MAINTAIN LINES AND LEVELS OF PANEL EDGES AND MOLDINGS. H.6. INSTALL PANELS TIGHT TO FLASH-COVED BASE TRIM. H.7. ALLOW 1/8-INCH GAP BETWEEN TOP CAP, CORNER, OR DIVISION MOLDING POSTS, AND PANEL EDGE; ALL EDGES SHALL BE FIRMLY BEDDED TO THE MOLDINGS IN SEALANT. H.8. PROMPTLY REMOVE SEALANT SQUEEZE OUT WITH A DAMP CLOTH, AS WORK PROGRESSES; REMOVE ADHESIVE WITH APPROPRIATE SOLVENT. H.9. INSTALL SEALANT BEHIND FLANGES AND AT PENETRATIONS THROUGH PANELING, AND BETWEEN TOP CAP OF PANEL AND SUBSTRATE. I. CLEANING I.1. INSPECT SURFACES OF PANELING AND REMOVE EXCESS ADHESIVE FROM FACE OF LAMINATE USING SOLVENT RECOMMENDED BY MANUFACTURER. I.2. PROMPTLY REMOVE UNUSED CUT PIECES FROM THE SITE. I.3. PRIOR TO SUBSTANTIAL COMPLETION OF EACH AREA WHERE REINFORCED PLASTIC PANEL WALL COVERING IS INSTALLED, CLEAN ALL SURFACES OF PLASTIC PANELS, USING PROCEDURES RECOMMENDED BY THE MANUFACTURER. H.1. ESTABLISH CENTERLINE OF EACH DISTINCT FLAT AREA TO BE COVERED. TRIM DIVISION MOLDINGS TO MATE WITH BASE MOLDINGS; INSTALL IN SOLID BED OF ADHESIVE, EITHER ON CENTERLINE, OR OFFSET 24 INCHES FROM CENTER, AS NECESSARY TO MAXIMIZE PANEL WIDTHS AT CORNERS. MOLDING SHALL BE INSTALLED STRAIGHT AND PLUMB. F.2. WHERE CONDITIONS REQUIRE INSTALLATION OF PANELING PRIOR TO INSTALLATION OF FLOORING, COORDINATE WITH OTHER TRADES TO ESTABLISH ACCURATE LOCATION OF TOP OF BASE. A. MATERIALS: A.1. ACOUSTIC INSULATION: ASTM C665, TYPE I; UNFACED MINERAL FIBER BATTS, BLANKETS, OR ROLLS; MINIMUM FIRE HAZARD CLASSIFICATION RATING OF 25/50 PER ASTM E84; MINIMUM 3-INCH THICK, UNLESS REQUIRED OTHERWISE TO MEET THE STC REQUIREMENTS INDICATED OR SPECIFIED; WIDTHS TO FRICTION-FIT BETWEEN STUDS, WHERE INDICATED FOR INSTALLATION IN STUD WALLS. A.2. ACOUSTICAL SEALANT: NON-HARDENING, NON-SKINNING, FOR USE IN CONJUNCTION WITH GYPSUM BOARD; SIMILAR TO USG "ACOUSTICAL SEALANT." A.3. SPRAYED FOAM: REFER TO ARCHITECTURAL DRAWINGS A.4. PREFORMED FOAM FILLER: FOAM ASSEMBLIES AVAILABLE FROM THE METAL DECK MANUFACTURER THAT ARE PREFORMED TO FIT THE FLUTES IN THE METAL DECK. A.5. ACCESSORIES: FURNISH OTHER ACCESSORIES SUCH AS FASTENERS AND RETAINERS, NOT SPECIFICALLY DESCRIBED, BUT REQUIRED FOR A COMPLETE INSTALLATION. B. INSTALLATION: B.1. INSTALL INSULATION IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, AND AS INDICATED. B.2. INSTALL INSULATION WITHOUT GAPS OR VOIDS. B.3. TRIM INSULATION NEATLY TO FIT SPACES. USE INSULATION MATERIALS FREE OF DAMAGE. B.4. ACOUSTICAL INSULATION AT CEILINGS: B.4.1. LAY ACOUSTICAL INSULATION OVER EACH ACOUSTICALLY INSULATED PARTITION THAT TERMINATES AT THE CEILING. INSULATION SHALL EXTEND A MINIMUM OF 24" EACH SIDE OF THE CENTERLINE OF THE ACOUSTICAL PARTITION. B.4.2. ACOUSTICAL INSULATION BATTS SHALL BE TIGHTLY BUTTED. B.4.3. CUT AND FIT NEATLY AROUND MECHANICAL AND SPRINKLER DROPS. B.4.4. FILL SPACES BETWEEN WALL BATTS (AT TOP PLATE LINE) AND CEILING BATTS TO ENSURE COMPLETE SOUND CLOSURE. B.4.5. OMIT INSULATION OVER TOPS OF RECESSED FLUORESCENT LIGHT FIXTURES; AND WITHIN 2 INCHES OF RECESSED INCANDESCENT FIXTURES. B.5. SEALANT: B.5.1. INSTALL ACOUSTICAL SEALANT AROUND PERIMETER OF ALL ACOUSTICALLY INSULATED PARTITIONS; ONE CONTINUOUS BEAD AT EACH SIDE OF FRAMING MEMBER INTERFACE WITH SUBSTRATE. B.5.2. SEAL ALL PENETRATIONS THROUGH ACOUSTICAL ASSEMBLIES, EXCEPT FOR PENETRATIONS IN FIRE RATED CONSTRUCTION TO RECEIVE FIRESTOPPING. B.6. PROVIDE PREFORMED FOAM FILLERS OR SPRAYED FOAM TO SEAL THE FLUTE OPENINGS WHERE ACOUSTICAL PARTITIONS ARE INSTALLED TIGHT TO METAL DECK ASSEMBLIES. FIELD VERIFICATION: FIELD VERIFY, PRIOR TO INSTALLATION, EXACT LAYOUT DIMENSIONS OF ALL SEAMS, FLOOR PATTERNS, GRAIN DIRECTIONS AND INSETS WITH ARCHITECT. START OF WORK WITHOUT ARCHITECT APPROVAL OF FIELD VERIFICATION IS NOT PERMITTED AND UNAUTHORIZED INSTALLATIONS SHALL BE REPLACED AT CONTRACTORS EXPENSE. WHERE MOVEABLE PARTITIONS ARE SHOWN, INSTALL LUXURY VINYL TILE BEFORE PARTITIONS ARE ERECTED. INSTALL FLOORING USING METHOD INDICATED IN STRICT COMPLIANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS. EXTEND FLOORING INTO TOE SPACES, DOOR REVEALS AND INTO CLOSETS AND SIMILAR OPENINGS. SCRIBE, CUT AND FIT LUXURY VINYL TILE TO PERMANENT FIXTURES BUILT IN FURNITURE AND CABINETS, PIPES, OUTLETS AND PERMANENT COLUMNS, WALLS AND PARTITIONS. MAINTAIN REFERENCE MARKERS, HOLES OR OPENINGS THAT ARE IN PLACE OR PLAINLY MARKED FOR FUTURE CUTTING BY REPEATING ON FINISH FLOORING AS MARKED ON SUBFLOOR. USE CHALK OR OTHER NON-PERMANENT MARKING DEVICE. INSTALL FLOORING ON COVERS FOR TELEPHONE AND ELECTRICAL DUCTS, AND OTHER SUCH ITEMS AS OCCUR WITHIN FINISHED FLOOR AREAS. MAINTAIN OVERALL CONTINUITY OF COLOR AND PATTERN WITH PIECES OF FLOORING INSTALLED ON THESE COVERS. TIGHTLY CEMENT EDGES TO PERIMETER OF FLOOR AROUND COVERS AND TO COVERS. TIGHTLY ADHERE FLOORING TO SUBBASE WITHOUT OPEN CRACKS, VOIDS, RAISING AND PUCKERING AT JOINTS, TELEGRAPHING OF ADHESIVE SPREADER MARKS OR OTHER SURFACE IMPERFECTIONS. HAND ROLL FLOORING AT PERIMETER OF EACH COVERED AREA TO ASSURE ADHESION. INSTALLATION OF TILE FLOORS: LAY TILE FROM CENTER MARKS ESTABLISHED WITH PRINCIPAL WALLS, DISCOUNTING MINOR OFFSETS, SO THAT TILE AT OPPOSITE EDGES OF ROOM ARE OF EQUAL WIDTH. ADJUST AS NECESSARY TO AVOID USE OF CUT WIDTHS LESS THAN 1/2 TILE AT ROOM PERIMETERS. LAY TILE SQUARE TO ROOM AXIS, UNLESS OTHERWISE SHOWN. MATCH TILES FOR COLOR AND PATTERN BY USING TILE FROM CARTONS IN SAME SEQUENCE AS MANUFACTURED AND PACKAGED IF SO NUMBERED. CUT TILE NEATLY AROUND ALL FIXTURES. BROKEN, CRACKED, CHIPPED OR DEFORMED TILES ARE NOT ACCEPTABLE. LAY TILE WITH GRAIN RUNNING IN ONE DIRECTION UNLESS SHOWN OR DIRECTED OTHERWISE. VERIFY GRAIN DIRECTIONS WITH ARCHITECT PRIOR TO INSTALLATION. ADHERE TILE FLOORING TO SUBSTRATES USING FULL SPREAD OF ADHESIVE APPLIED IN COMPLIANCE WITH FLOORING MANUFACTURER'S DIRECTIONS. ON ALL FLOOR PENETRATIONS CUTOUTS AND EDGE CONDITIONS, SUCH AS DOOR FRAMES, FILL VOIDS BETWEEN TILE FLOOR AND OTHER SURFACES WITH SEALANT RECOMMENDED BY TILE MANUFACTURER. TRANSITION SECTION AT PAVING JUNCTION: VISEDGE VR BY HOWIE GREEN IS DESIGNED TO SECURELY ANCHOR THE PERIMETER OF TILE FLOORING TO PREVENT INGRESS OF WATER AT THE INTERFACE WITH THE SCREED AND TO PROTECT THE CERAMIC FLOOR EDGE PROFILE. INSTALLATION OF ACCESSORIES: APPLY WALL BASE TO WALLS, COLUMNS, PILASTERS, CASEWORK AND OTHER PERMANENT FIXTURES IN ROOMS OR AREAS WHERE BASE IS REQUIRED. INSTALL BASE IN LENGTHS AS LONG AS PRACTICABLE, WITH PREFORMED CORNER UNITS. TIGHTLY BOND BASE TO SUBSTRATE THROUGHOUT LENGTH OF EACH PIECE, WITH CONTINUOUS CONTACT AT HORIZONTAL AND VERTICAL SURFACES. ON MASONRY SURFACES, OR OTHER SIMILAR IRREGULAR SUBSTRATES, FILL VOIDS ALONG TOP EDGE OF RESILIENT WALL BASE WITH MANUFACTURER'S RECOMMENDED ADHESIVE FILLER MATERIAL. PLACE RESILIENT EDGE STRIPS TIGHTLY BUTTED TO FLOORING AND SECURE WITH ADHESIVE. INSTALL EDGING STRIPS AT EDGES OF FLOORING WHICH WOULD OTHERWISE BE EXPOSED. APPLY RESILIENT ACCESSORIES TO STAIRS IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. CLEANING AND PROTECTION: PERFORM FOLLOWING OPERATIONS IMMEDIATELY UPON COMPLETION OF LUXURY VINYL TILE: SWEEP OR VACUUM FLOOR THOROUGHLY. DO NOT WASH FLOOR UNTIL TIME PERIOD RECOMMENDED BY LUXURY VINYL TILE MANUFACTURER HAS ELAPSED TO ALLOW LUXURY VINYL TILE TO BECOME WELL ADHERED. SPRAY BUFFING USING A WHITE OR LAMB'S WOOL PAD IS ALSO A VERY EFFECTIVE AND ECONOMICAL METHOD OF MAINTAINING A HIGH STANDARD OF APPEARANCE. DAMP MOP FLOOR BEING CAREFUL TO REMOVE BLACK MARKS AND EXCESSIVE SOIL. REMOVE ANY EXCESS ADHESIVE OR OTHER SURFACE BLEMISHES, USING APPROPRIATE CLEANER RECOMMENDED BY FLOORING MANUFACTURERS. PROTECT FLOORING AGAINST DAMAGE DURING CONSTRUCTION PERIOD TO COMPLY WITH LUXURY VINYL TILE MANUFACTURER'S DIRECTIONS. IF REQUIRED BY OWNER, APPLY PROTECTIVE FLOOR POLISH TO LUXURY VINYL TILE SURFACES FREE FROM SOIL, EXCESS ADHESIVE OR SURFACE BLEMISHES. USE COMMERCIALLY AVAILABLE METAL CROSS-LINKED ACRYLIC PRODUCT ACCEPTABLE TO LUXURY VINYL TILE MANUFACTURER. PROTECT FLOORING AGAINST DAMAGE FROM ROLLING LOADS FOR INITIAL PERIOD FOLLOWING INSTALLATION BY COVERING WITH PLYWOOD OR HARDBOARD. USE DOLLIES TO MOVE STATIONARY EQUIPMENT OR FURNISHINGS ACROSS FLOORS. COVER LUXURY VINYL TILE WITH UNDYED, UNTREATED BUILDING PAPER UNTIL INSPECTION FOR SUBSTANTIAL COMPLETION. CLEAN LUXURY VINYL TILE NOT MORE THAN FOUR DAYS PRIOR TO DATE SCHEDULED FOR INSPECTIONS INTENDED TO ESTABLISH DATE OF SUBSTANTIAL COMPLETION IN EACH AREA OF PROJECT. CLEAN RESILIENT FLOORING BY METHOD RECOMMENDED BY LUXURY VINYL TILE MANUFACTURER. STRIP PROTECTIVE FLOOR POLISH, WHICH WAS APPLIED AFTER COMPLETION OF INSTALLATION, PRIOR TO CLEANING. REAPPLY FLOOR POLISH AFTER CLEANING. EXTRA MATERIALS: FURNISH EXTRA MAINTENANCE MATERIALS TO OWNER. FURNISH EXTRA MATERIALS FROM SAME MANUFACTURED LOT AS MATERIALS INSTALLED. DELIVER TO OWNER ENCLOSED IN PROTECTIVE PACKAGING WITH APPROPRIATE IDENTIFYING LABELS. TILE FLOORING: FURNISH NOT LESS THAN ONE BOX FOR 50 BOXES OR FRACTION THEREOF, FOR EACH TYPE, COLOR, PATTERN AND SIZE INSTALLED. RESILIENT ACCESSORIES: FURNISH NOT LESS THAN TEN LINEAR FEET FOR EACH 500 LINEAR FEET OR FRACTION THEREOF, OF EACH TYPE, SIZE, COLOR AND PATTERN INSTALLED. END OF SECTION 09650 C.2. CLEAN BASE AND FLOOR IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. C.6. HORIZONTAL SEAMS ARE NOT PERMITTED. C.7. CORNER SEAMS: MAKE NO SEAMS WITHIN 6 INCHES OF AN INSIDE OR OUTSIDE CORNER, EXCEPT WHERE A COLOR OR PATTERN CHANGE IS INDICATED. LAP WALL COVERINGS AT INSIDE CORNER SEAMS TO PREVENT SUBSTRATE SHOW THROUGH. C.8. FABRICS: C.8.1. USE FABRIC ROLLS IN CONSECUTIVE NUMERICAL SEQUENCE OF MANUFACTURE. C.8.2. PLACE FABRIC SECTIONS CONSECUTIVELY IN EXACT ORDER IN WHICH THEY ARE CUT FROM THE ROLL INCLUDING FILLING ALL SPACESABOVE OR BELOW WINDOWS, DOORS, RELIGHTS, OR SIMILAR PENETRATIONS. C.8.3. TRIM PATTERNED FABRICS WHICH ARE NOT FACTORY PRETRIMMED ON A WORK TABLE WITH A STRAIGHT EDGE AND AN INDUSTRIAL RAZOR BLADE FOR EXACT PATTERN MATCH. C.9. INSTALL WALL COVERING SECURE, SMOOTH AND FREE OF WRINKLES, GAPS AND OVERLAPS. D. CLEANUP D.1. REPLACE ALL REMOVED WALL PLATES AND OTHER ACCESSORIES. D.2. REPAIR TO LIKE-NEW CONDITION, OR REPLACE AS DIRECTED BY THE OWNER'S REPRESENTATIVE, ALL SURFACES DAMAGED BY WORK OF THIS SECTION. F.1.1. INTERMEDIATE COAT (OVER SHOP PRIMER): TNEMEC SERIES 69 "EPOXOLINE II". F.1.2. POLYURETHANE FINISH COATS: SERIES 175 "ENDURA-SHIELD" ACRYLIC POLYURETHANE ENAMEL; SEMI-EGGSHELL SHEEN. F.1.3. APPLICATION: EXTERIOR FERROUS AND GALVANIZED METAL SURFACES INCLUDING HOLLOW STEEL METAL DOORS AND FRAMES AND BOLLARDS. G. INTERIOR SYSTEMS: G.1. INTERIOR FERROUS AND GALVANIZED METAL - ACRYLIC G.1.2. SHEEN: SEMI-GLOSS, UNLESS INDICATED OTHERWISE. G.2. BACK OF HOUSE: 1 COAT PRIMER, 1 COAT FINISH A. SECTION INCLUDES: A.1. PLASTIC SIGNAGE. A.2. VINYL SIGNAGE. B. REFERENCES: B.1. AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) - LATEST EDITION. B.2. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) A117.1, LATEST EDITION. C. PLASTIC SIGNAGE: C.1. MATERIALS: C.1.1. PLASTIC SHEET: 1/8 INCH THICK ACRYLIC SHEET; BLUE; LOW GLOSS FINISH. C.1.2. ADHESIVE MOUNTING TAPE: 3M "SCOTCH BRAND #665" DOUBLE-STICK, DOUBLE-COATED TAPE, 1/4" WIDE. C.1.3. RAISED LETTERING: HELVETICA MEDIUM TYPEFACE; WHITE COLOR; 1 INCH HEIGHT; 1/32 INCH RELIEF; SELF-ADHESIVE. C.1.4. BRAILLE: ANSI GRADE II, SELF-ADHESIVE; COLOR TO MATCH ACRYLIC SHEET. C.1.5. PICTOGRAMS: ANSI COMPLIANT; SELF-ADHESIVE. C.2. DIMENSIONS: 4-1/2 INCHES HIGH, WITH WIDTH DETERMINED BY SPECIFIED TEXT; MINIMUM 3/4 INCH BORDER UNLESS INDICATED OTHERWISE; 1/2 INCH RADIUS CORNERS. C.3. SIGNS: C.3.1. FOR EACH TOILET ROOM DOOR: "MEN" OR "WOMEN" AS APPROPRIATE; BLUE WITH WHITE LETTERS; ACCOMPANIED WITH GRADE 2 BRAILLE SYMBOL; OVERALL SIGN TO BE 2-1/2 INCH HIGH BY LENGTH REQUIRED. C.3.2. FOR EACH TOILET ROOM DOOR: INTERNATIONAL SYMBOL OF ACCESSIBILITY: NOMINAL 3 INCHES BY 3 INCHES; STANDARD BLUE AND WHITE. D. VINYL SIGNS: D.1. TYPE: PRESSURE SENSITIVE ADHESIVE BACK; MACHINE BLADE CUT; CUSTOM COLORS AS SCHEDULED. D.1.1. TEXT: AS SCHEDULED BELOW. D.1.2. STYLE/SIZE: HELVETICA MEDIUM; 1" HIGH, UNLESS OTHERWISE INDICATED. D.1.3. SUBMIT SIGN FOR APPROVAL. D.2. SCHEDULE: D.2.1. SUITE NUMBERS: 3" HIGH INDIVIDUAL LETTERS; TEXT AND COLOR AS DIRECTED BY OWNER'S REPRESENTATIVE AND LANDLORD REQUIREMENTS. D.2.2. AT ENTRY DOORS IN IBC JURISDICTIONS: "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS;" SINGLE SIGN AT EACH ENTRY; SIZE AS REQUIRED; PROVIDE LETTERS IN COLOR WHICH CONTRAST DISTINCTLY FROM BACKGROUND (FRAME) COLOR. D.2.3. AT ENTRY DOORS IN OTHER JURISDICTIONS: WORDING AS INDICATED, OR VERIFY WITH LOCAL CODE AUTHORITY FOR CORRECT WORDING OF SIGN IF WORDING NOT INDICATED; PROVIDE LETTERS IN COLOR WHICH CONTRAST DISTINCTLY FROM BACKGROUND (FRAME) COLOR. D.2.4. "EMERGENCY EXIT ONLY" ON REAR EXTERIOR DOOR (WHERE APPLIES); BLUE WITH WHITE LETTERS; MOUNT AT +66" AFF. E. FABRICATION: E.1. SIGNS SHALL BE FREE OF ROUGH EDGES, IRREGULAR SURFACES, NON-UNIFORM FINISHES, AND OTHER DEFECTS. E.2. PROVIDE PICTOGRAMS WITH ACCURATE COLOR MATCH WITH RAISED LETTERING. E.3. APPLY ADHESIVE PICTOGRAMS AND RAISED LETTERING CAREFULLY, IN ACCURATE ALIGNMENT. F. INSTALLATION OF PLASTIC SIGNAGE: F.1. CLEAN SURFACES TO RECEIVE SIGNAGE. F.2. INSTALL SIGNAGE AS REFERENCED IN THE GRAPHICS SCHEDULE AND OTHER ITEMS AS SPECIFIED BELOW. F.3. GRAPHICS SHALL BE MOUNTED LEVEL, AND PLUMB. F.4. APPLY SIGNAGE WITH TOP EDGE LOCATED 60 INCHES ABOVE THE FINISH FLOOR SURFACE UNLESS INDICATED OTHERWISE. USE SPECIFIED ADHESIVE MOUNTING TAPE; THE TAPE SHALL NOT BE VISIBLE IN THE INSTALLED POSITION. G. INSTALLATION OF VINYL SIGNS: G.1. ADHERE BY REMOVING PROTECTIVE BACKING SHEET AND PRESSING FIRMLY TO SURFACE, FOLLOWING ACCURATE SPACING. G.2. REMOVE ALL RESIDUE AROUND LETTERS, WIPE CLEAN. H. CLEANUP: H.1. TAKE PRECAUTIONS TO ASSURE ADJACENT SURFACES REMAIN FREE FROM DUST, AND ADHESIVE. H.2. IMMEDIATELY CLEAN SURFACES THAT BECOME SOILED DURING INSTALLATION OF THE LETTERS. H.3. UPON INSTALLATION, CLEAN THE LETTERS AND PIN MOUNTS OF DUST WITH A DAMP CLOTH, TAKING CARE NOT TO DAMAGE UNDERLYING SURFACES. H.4. LEAVE THE INSTALLATION CLEAN, AND COMPLETELY FREE OF FOREIGN MATERIAL THAT WOULD DETRACT FROM VISUAL APPEARANCE OF THE LETTERS. A. DELIVERY, STORAGE AND HANDLING A.1. DO NOT DELIVER ACCESSORIES TO SITE UNTIL ROOMS IN WHICH THEY ARE TO BE INSTALLED ARE READY TO RECEIVE THEM. A.2. PACK ACCESSORIES INDIVIDUALLY IN A MANNER TO PROTECT ACCESSORY AND ITS FINISH. B. GENERAL: B.1. PROVIDE ACCESSORIES AS MANUFACTURED BY BOBRICK WASHROOM EQUIPMENT COMPANY UNLESS OTHERWISE INDICATED, IN QUANTITIES INDICATED ON THE DRAWINGS. B.2. ALL PRODUCTS SHALL BE SATIN STAINLESS STEEL, UNLESS OTHERWISE INDICATED. C. PRODUCTS IN RESTROOMS: (REFER TO SHEET A7.0, NO SUBSTITUTIONS ALLOWED) D. PREPARATION: D.1. DELIVER INSERTS AND ROUGH-IN FRAMES TO JOB SITE AT APPROPRIATE TIME FOR BUILDING-IN. D.2. FURNISH TEMPLATES AND ROUGH-IN MEASUREMENTS AS REQUIRED. D.3. BEFORE STARTING WORK NOTIFY OWNER'S REPRESENTATIVE IN WRITING OF CONFLICTS DETRIMENTAL TO INSTALLATION OR OPERATION OF UNITS. D.4. PROTECT ADJACENT OR ADJOINING FINISHED SURFACES FROM DAMAGE DURING INSTALLATION OF WORK OF THIS SECTION. D.5. VERIFY EXACT LOCATION OF ACCESSORIES. E. INSTALLATION: E.1. INSTALL FIXTURES, ACCESSORIES AND ITEMS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. E.2. INSTALL TRUE, PLUMB, AND LEVEL, SECURELY AND RIGIDLY ANCHORED TO SUBSTRATE. E.3. USE TAMPER-PROOF FASTENERS. A. CORNER GUARDS: A.1. REFER TO ARCHITECTURAL DRAWINGS FOR SPECIFICATION A.2. PAWLING CORNER GUARD; FURNISH WITH PREDRILLED COUNTERSUNK MOUNTING HOLES AND CHROME PLATED OVAL HEAD MOUNTING SCREWS. B. FIRE EXTINGUISHER DRY CHEMICAL TYPE - ABC MULTIPURPOSE TYPE: B.1. TYPE: STANDARD FIRE-WEST MODEL ABC-5, POTTER-ROEMER MODEL NO. 3005, LARSEN'S MANUFACTURING COMPANY MODEL MP5, J.L. INDUSTRIES COSMIC 5E, OR APPROVED. B.2. 5 LB. CAPACITY, UL RATED 2A-10B:C, APPROXIMATELY 4-1/2 INCH DIAMETER X 14 INCHES HIGH, BAKED ENAMEL STEEL SHELL. B.3. AGENT: AMMONIUM PHOSPHATE BASE. B.4. LOCATION: REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF SURFACE MOUNTED FIRE EXTINGUISHERS G.1.1. SYSTEM: SYSTEM: THREE COATS; FIRST COAT ACRYLIC DTM PRIMER; SECOND AND THIRD COATS LATEX FINISH. THE PRIMER MAY BE OMITTED AT FACTORY-PRIMED SURFACES, EXCEPT AS NECESSARY TO RECOAT DAMAGED OR ABRADED PREPRIMED SURFACES. G.1.3. APPLICATION: INTERIOR FERROUS METAL SURFACES INCLUDING HOLLOW STEEL METAL DOORS, ACCESS DOORS AND PANELS, AND FIRE EXTINGUISHER CABINETS. G.1.4. GYPSUM BOARD: 2 COATS PRIMER, 2 COATS OF LATEX PAINT. INTERIOR GYPSUM BOARD SURFACES, UNLESS NOTED OTHERWISE. A. SUMMARY: FIELD APPLIED PAINT COATINGS. B. QUALITY ASSURANCE: B.1. PAINT COATINGS SHALL BE FREE OF DUST, DIRT, FLOW LINES, STREAKS, SAGS, BLISTERS, PINHOLES, RUNS, OR OTHER SURFACE IMPERFECTIONS. B.2. IN ADDITION TO THE COATS SPECIFIED, PROVIDE ADDITIONAL COATS AS REQUIRED TO OBTAIN ADEQUATE HIDE. C. PAINTS: "FIRST QUALITY" COMMERCIAL GRADE PRODUCTS FROM BENJAMIN MOORE PAINT COMPANY, NO EXCEPTIONS. D. SURFACE PREPARATION: ALL SURFACES SHALL BE CLEAN, DRY AND FREE OF FOREIGN MATERIAL, AND SURFACES MADE SMOOTH, PRIOR TO THE APPLICATION OF PAINT. E. SPECIAL APPLICATION REQUIREMENTS; INTERIOR GYPSUM WALL BOARD: ROLLER APPLICATION OR SPRAY APPLICATION FOLLOWED BY BACK ROLLING F. EXTERIOR SYSTEMS: F.1. PREPRIMED EXTERIOR FERROUS METALS: (CONTINUED ON NEXT PAGE)B. RETRACTABLE CROWD CONTROL BELTS SUPPLIER: CROWDCONTROLSTORE.COM, 1-800-470-3118 (2) TENSABARRIER 897 (NOT USED) (NOT USED) (NOT USED) (NOT USED) (SEE MECHANICAL SHEETS) (SEE ELECTRICAL SHEETS) WALL MOUNT RETRACTABLE BELT BARRIER BLACK BODY, BLACK CAPS 30 FEET BELT LENGTH WALL ATTACHMENT STANDARD BELT DESIGN GRAY BELT END STANDARD RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt SPECIFICATIONS G504 DIVISION 10:SPECIALTIES SECTION 10400 SIGNAGE SECTION 10810 TOILET ACCESSORIES SECTION 10999 MISCELLANEOUSSECTION 09900 PAINTING DIVISION 11 - EQUIPMENT DIVISION 12 - FURNISHINGS DIVISION 13 - SPECIAL CONSTRUCTION DIVISION 14 - CONVEYING SYSTEMS DIVISION 15 - MECHANICAL DIVISION 16 - ELECTRICAL G. INTERIOR SYSTEMS: G.1. INTERIOR FERROUS AND GALVANIZED METAL - ACRYLIC G.1.2. SHEEN: SEMI-GLOSS, UNLESS INDICATED OTHERWISE. G.2. BACK OF HOUSE: 1 COAT PRIMER, 1 COAT FINISH A. SECTION INCLUDES: A.1. PLASTIC SIGNAGE. A.2. VINYL SIGNAGE. B. REFERENCES: B.1. AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) - LATEST EDITION. B.2. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) A117.1, LATEST EDITION. C. PLASTIC SIGNAGE: C.1. MATERIALS: C.1.1. PLASTIC SHEET: 1/8 INCH THICK ACRYLIC SHEET; BLUE; LOW GLOSS FINISH. C.1.2. ADHESIVE MOUNTING TAPE: 3M "SCOTCH BRAND #665" DOUBLE-STICK, DOUBLE-COATED TAPE, 1/4" WIDE. C.1.3. RAISED LETTERING: HELVETICA MEDIUM TYPEFACE; WHITE COLOR; 1 INCH HEIGHT; 1/32 INCH RELIEF; SELF-ADHESIVE. C.1.4. BRAILLE: ANSI GRADE II, SELF-ADHESIVE; COLOR TO MATCH ACRYLIC SHEET. C.1.5. PICTOGRAMS: ANSI COMPLIANT; SELF-ADHESIVE. C.2. DIMENSIONS: 4-1/2 INCHES HIGH, WITH WIDTH DETERMINED BY SPECIFIED TEXT; MINIMUM 3/4 INCH BORDER UNLESS INDICATED OTHERWISE; 1/2 INCH RADIUS CORNERS. C.3. SIGNS: C.3.1. FOR EACH TOILET ROOM DOOR: "MEN" OR "WOMEN" AS APPROPRIATE; BLUE WITH WHITE LETTERS; ACCOMPANIED WITH GRADE 2 BRAILLE SYMBOL; OVERALL SIGN TO BE 2-1/2 INCH HIGH BY LENGTH REQUIRED. C.3.2. FOR EACH TOILET ROOM DOOR: INTERNATIONAL SYMBOL OF ACCESSIBILITY: NOMINAL 3 INCHES BY 3 INCHES; STANDARD BLUE AND WHITE. D. VINYL SIGNS: D.1. TYPE: PRESSURE SENSITIVE ADHESIVE BACK; MACHINE BLADE CUT; CUSTOM COLORS AS SCHEDULED. D.1.1. TEXT: AS SCHEDULED BELOW. D.1.2. STYLE/SIZE: HELVETICA MEDIUM; 1" HIGH, UNLESS OTHERWISE INDICATED. D.1.3. SUBMIT SIGN FOR APPROVAL. D.2. SCHEDULE: D.2.1. SUITE NUMBERS: 3" HIGH INDIVIDUAL LETTERS; TEXT AND COLOR AS DIRECTED BY OWNER'S REPRESENTATIVE AND LANDLORD REQUIREMENTS. D.2.2. AT ENTRY DOORS IN IBC JURISDICTIONS: "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS;" SINGLE SIGN AT EACH ENTRY; SIZE AS REQUIRED; PROVIDE LETTERS IN COLOR WHICH CONTRAST DISTINCTLY FROM BACKGROUND (FRAME) COLOR. D.2.3. AT ENTRY DOORS IN OTHER JURISDICTIONS: WORDING AS INDICATED, OR VERIFY WITH LOCAL CODE AUTHORITY FOR CORRECT WORDING OF SIGN IF WORDING NOT INDICATED; PROVIDE LETTERS IN COLOR WHICH CONTRAST DISTINCTLY FROM BACKGROUND (FRAME) COLOR. D.2.4. "EMERGENCY EXIT ONLY" ON REAR EXTERIOR DOOR (WHERE APPLIES); BLUE WITH WHITE LETTERS; MOUNT AT +66" AFF. E. FABRICATION: E.1. SIGNS SHALL BE FREE OF ROUGH EDGES, IRREGULAR SURFACES, NON-UNIFORM FINISHES, AND OTHER DEFECTS. E.2. PROVIDE PICTOGRAMS WITH ACCURATE COLOR MATCH WITH RAISED LETTERING. E.3. APPLY ADHESIVE PICTOGRAMS AND RAISED LETTERING CAREFULLY, IN ACCURATE ALIGNMENT. F. INSTALLATION OF PLASTIC SIGNAGE: F.1. CLEAN SURFACES TO RECEIVE SIGNAGE. F.2. INSTALL SIGNAGE AS REFERENCED IN THE GRAPHICS SCHEDULE AND OTHER ITEMS AS SPECIFIED BELOW. F.3. GRAPHICS SHALL BE MOUNTED LEVEL, AND PLUMB. F.4. APPLY SIGNAGE WITH TOP EDGE LOCATED 60 INCHES ABOVE THE FINISH FLOOR SURFACE UNLESS INDICATED OTHERWISE. USE SPECIFIED ADHESIVE MOUNTING TAPE; THE TAPE SHALL NOT BE VISIBLE IN THE INSTALLED POSITION. G. INSTALLATION OF VINYL SIGNS: G.1. ADHERE BY REMOVING PROTECTIVE BACKING SHEET AND PRESSING FIRMLY TO SURFACE, FOLLOWING ACCURATE SPACING. G.2. REMOVE ALL RESIDUE AROUND LETTERS, WIPE CLEAN. H. CLEANUP: H.1. TAKE PRECAUTIONS TO ASSURE ADJACENT SURFACES REMAIN FREE FROM DUST, AND ADHESIVE. H.2. IMMEDIATELY CLEAN SURFACES THAT BECOME SOILED DURING INSTALLATION OF THE LETTERS. H.3. UPON INSTALLATION, CLEAN THE LETTERS AND PIN MOUNTS OF DUST WITH A DAMP CLOTH, TAKING CARE NOT TO DAMAGE UNDERLYING SURFACES. H.4. LEAVE THE INSTALLATION CLEAN, AND COMPLETELY FREE OF FOREIGN MATERIAL THAT WOULD DETRACT FROM VISUAL APPEARANCE OF THE LETTERS. A. DELIVERY, STORAGE AND HANDLING A.1. DO NOT DELIVER ACCESSORIES TO SITE UNTIL ROOMS IN WHICH THEY ARE TO BE INSTALLED ARE READY TO RECEIVE THEM. A.2. PACK ACCESSORIES INDIVIDUALLY IN A MANNER TO PROTECT ACCESSORY AND ITS FINISH. B. GENERAL: B.1. PROVIDE ACCESSORIES AS MANUFACTURED BY BOBRICK WASHROOM EQUIPMENT COMPANY UNLESS OTHERWISE INDICATED, IN QUANTITIES INDICATED ON THE DRAWINGS. B.2. ALL PRODUCTS SHALL BE SATIN STAINLESS STEEL, UNLESS OTHERWISE INDICATED. C. PRODUCTS IN RESTROOMS: (REFER TO SHEET A7.0, NO SUBSTITUTIONS ALLOWED) D. PREPARATION: D.1. DELIVER INSERTS AND ROUGH-IN FRAMES TO JOB SITE AT APPROPRIATE TIME FOR BUILDING-IN. D.2. FURNISH TEMPLATES AND ROUGH-IN MEASUREMENTS AS REQUIRED. D.3. BEFORE STARTING WORK NOTIFY OWNER'S REPRESENTATIVE IN WRITING OF CONFLICTS DETRIMENTAL TO INSTALLATION OR OPERATION OF UNITS. D.4. PROTECT ADJACENT OR ADJOINING FINISHED SURFACES FROM DAMAGE DURING INSTALLATION OF WORK OF THIS SECTION. D.5. VERIFY EXACT LOCATION OF ACCESSORIES. E. INSTALLATION: E.1. INSTALL FIXTURES, ACCESSORIES AND ITEMS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. E.2. INSTALL TRUE, PLUMB, AND LEVEL, SECURELY AND RIGIDLY ANCHORED TO SUBSTRATE. E.3. USE TAMPER-PROOF FASTENERS. A. CORNER GUARDS: A.1. REFER TO ARCHITECTURAL DRAWINGS FOR SPECIFICATION A.2. PAWLING CORNER GUARD; FURNISH WITH PREDRILLED COUNTERSUNK MOUNTING HOLES AND CHROME PLATED OVAL HEAD MOUNTING SCREWS. B. FIRE EXTINGUISHER DRY CHEMICAL TYPE - ABC MULTIPURPOSE TYPE: B.1. TYPE: STANDARD FIRE-WEST MODEL ABC-5, POTTER-ROEMER MODEL NO. 3005, LARSEN'S MANUFACTURING COMPANY MODEL MP5, J.L. INDUSTRIES COSMIC 5E, OR APPROVED. B.2. 5 LB. CAPACITY, UL RATED 2A-10B:C, APPROXIMATELY 4-1/2 INCH DIAMETER X 14 INCHES HIGH, BAKED ENAMEL STEEL SHELL. B.3. AGENT: AMMONIUM PHOSPHATE BASE. B.4. LOCATION: REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF SURFACE MOUNTED FIRE EXTINGUISHERS G.1.1. SYSTEM: SYSTEM: THREE COATS; FIRST COAT ACRYLIC DTM PRIMER; SECOND AND THIRD COATS LATEX FINISH. THE PRIMER MAY BE OMITTED AT FACTORY-PRIMED SURFACES, EXCEPT AS NECESSARY TO RECOAT DAMAGED OR ABRADED PREPRIMED SURFACES. F.1.1. INTERMEDIATE COAT (OVER SHOP PRIMER): TNEMEC SERIES 69 "EPOXOLINE II". F.1.2. POLYURETHANE FINISH COATS: SERIES 175 "ENDURA-SHIELD" ACRYLIC POLYURETHANE ENAMEL; SEMI-EGGSHELL SHEEN. F.1.3. APPLICATION: EXTERIOR FERROUS AND GALVANIZED METAL SURFACES INCLUDING HOLLOW STEEL METAL DOORS AND FRAMES AND BOLLARDS. G.1.3. APPLICATION: INTERIOR FERROUS METAL SURFACES INCLUDING HOLLOW STEEL METAL DOORS, ACCESS DOORS AND PANELS, AND FIRE EXTINGUISHER CABINETS. G.1.4. GYPSUM BOARD: 2 COATS PRIMER, 2 COATS OF LATEX PAINT. INTERIOR GYPSUM BOARD SURFACES, UNLESS NOTED OTHERWISE. A. SUMMARY: FIELD APPLIED PAINT COATINGS. B. QUALITY ASSURANCE: B.1. PAINT COATINGS SHALL BE FREE OF DUST, DIRT, FLOW LINES, STREAKS, SAGS, BLISTERS, PINHOLES, RUNS, OR OTHER SURFACE IMPERFECTIONS. B.2. IN ADDITION TO THE COATS SPECIFIED, PROVIDE ADDITIONAL COATS AS REQUIRED TO OBTAIN ADEQUATE HIDE. C. PAINTS: "FIRST QUALITY" COMMERCIAL GRADE PRODUCTS FROM BENJAMIN MOORE PAINT COMPANY, NO EXCEPTIONS. D. SURFACE PREPARATION: ALL SURFACES SHALL BE CLEAN, DRY AND FREE OF FOREIGN MATERIAL, AND SURFACES MADE SMOOTH, PRIOR TO THE APPLICATION OF PAINT. E. SPECIAL APPLICATION REQUIREMENTS; INTERIOR GYPSUM WALL BOARD: ROLLER APPLICATION OR SPRAY APPLICATION FOLLOWED BY BACK ROLLING F. EXTERIOR SYSTEMS: F.1. PREPRIMED EXTERIOR FERROUS METALS: (CONTINUED ON NEXT PAGE)B. RETRACTABLE CROWD CONTROL BELTS SUPPLIER: CROWDCONTROLSTORE.COM, 1-800-470-3118 (2) TENSABARRIER 897 (NOT USED) (NOT USED) (NOT USED) (NOT USED) (SEE MECHANICAL SHEETS) (SEE ELECTRICAL SHEETS) WALL MOUNT RETRACTABLE BELT BARRIER BLACK BODY, BLACK CAPS 30 FEET BELT LENGTH WALL ATTACHMENT STANDARD BELT DESIGN GRAY BELT END STANDARD RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt SPECIFICATIONS G505 A405 3 A4051 UNIT B 3,770 S.F. (E) UNIT C N.I.C. 3,860 S.F. BUSINESS (E) UNIT A N.I.C. 1,834 S.F. BUSINESS PROJECT AREA A R C A D I A A V E S B A L D W I N A V E E32.08 E32.09E32.07 E32.12 E32.12 E32.12 E32.08 E32.08 22.38 E32.13 E32.13 E32.07 E32.15 E32.15 E32.01 E4.09 E4.09 E32.09 E32.10 32.10 E32.11 A405 2 3.08 E2.02 E26.02E26.02 E32.07 E32.13 5' - 0" E32.15 (E) 18' - 0" (E ) 9 ' - 0 " (E ) 8 ' - 7 " (E ) 9' - 0 " UP 18' - 7" 5' - 0" (E) 9' - 0" (E ) 1 8 ' - 0 " ROOF ACCESS LADDER OCCUPANCY: B OCCUPANCY: B 30' - 0" CENT ER LINE OF ST RE ET CE N T E R L I N E O F S T R E E T 50' - 0" PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE 74' - 3" 29' - 11" 11' - 11 1/2" 52' - 6" 8' - 9 1/2" 74' - 4 1/2" 2% MAX 2% MAX 5' - 0" 5' - 0 " 6' - 0 " 5' - 0" 3.05 3.05 3.05 10.74 10.74 10.74 E21.01 E22.31 E26.26 SITE ACCESSIBILITY NOTES: 1. DISABLED ACCESSIBLE PATH OF TRAVEL AS INDICATED ON PLAN IS A BARRIER FREE ACCESS ROUTE WITHOUT ANY ABRUPT LEVEL CHANGES EXCEEDING 1/2" IF BEVELED AT 1:2 MAX SLOPE, OR VERTICAL LEVEL CHANGES NOT EXCEEDING 1/4" MAX IN HEIGHT ALONG AND ADJACENT TO THE ACCESSIBLE ROUTE OF TRAVEL, AND AT LEAST 48" IN WIDTH. CROSS SLOPE DOES NOT EXCEED 2% AND SLOPE IN THE DIRECTION OF TRAVEL IS LESS THAN 5%, UNLESS OTHERWISE INDICATED. 2. ACCESSIBLE PATH OF TRAVEL SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM, AND PROTRUDING OBJECTS GREATER THAN 4" PROJECTION FROM WALL AND ABOVE 27" AND LESS THAN 80". 3. ACCESSIBLE ROUTE SURFACE MUST BE SLIP-RESISTANT, STABLE, AND FIRM. ON SURFACES WITH SLOPES UP TO 6%, PROVIDE EQUIVALENT OF MEDIUM SALTED FINISH. ON SURFACES WITH SLOPES EQUAL TO OR GREATER THAN 6%, PROVIDE SLIP-RESISTANT FINISH. BUILDING DEPAMENT NOTE: GRADING PERMIT MAY BE / IS REQUIRED. PLANS AND PERMIT FOR GRADING MAY BE PROCESSED AND ISSUED SEPARATELY FROM AND PRIOR TO THIS BUILDING PERMIT. ADA IS A FEDERAL LAW. CITY OF ARCADIA CAN NOT APPROVE PLANS FOR FEDERAL LAW, CITY APPROVES PLANS AND REVIEWS PLANS FOR 2022 CBC CHAPTER 11-B (DISABLED ACCESS REGULATIONS). NONE SCAPE OF WORK AREA. EXISTING TO REMAIN SITE PLAN LEGEND DISABLED ACCESSIBLE PATH OF TRAVEL 1. THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:20 (5%) (CBC 11B-403.3) 2. THE CROSS SLOPE OF WALKING SURFACES SHALL NOT BE STEEPER THAN 1:48 (2%) (CBC 11B-403.3) 3. THE CLEAR WIDTH SHALL BE 48 INCHES MINIMUM (CBC 11B-403.5.1 EXCEPTION 3 AND 11B-405.5) 4. FLOOR AND GROUND SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANTAND SHALL COMPLY WITH SECTION 11B-302. N RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt SITE PLAN .AS1013/32" = 1'-0"1SITE PLAN KEY NOTE # DESCRIPTION 3.05 PROVIDE 2% MAX DOOR LANDING AT THE EXISTING SIDE WALK 3.08 EXTERIOR STONE PAVERS 10.74 PROVIDE ENTRY DOOR ADA SIGN AT ENTRY DOOR. SEE DETAIL 10/G404 22.38 GREASE INTERCEPTOR SERVICE PORT, RECESSED INTO THE GROUND. SEE PLUMBING DWG 32.10 TRUNCATED DOME E2.02 (E) STORM DRAIN E4.09 (E) CMU SITE WALL E21.01 (E) FIRE SPRINKLER RISER E22.31 (E) GAS METER, SEE PLUMBING DWG E26.02 (E) TRANSFORMER E26.26 (E) ELETRICAL CLOSET,SWITCH GEAR. E32.01 (E) ASPHALT PAVING E32.07 (E) LANDSCAPE AREA E32.08 (E) ACCESSIBLE PARKING SPACE E32.09 (E) PARKING E32.10 (E) TRUNCATED DOME E32.11 (E) CONCRETE WALKWAY E32.12 (E) CONCRETE RAMP E32.13 (E) CONCRETE SIDE WALK E32.15 (E) DRIVEWAY GENERAL NOTES (E ) T R A S H EN C L O S U R E A B C D D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.11 D9.10 D9.10 D9.10 D9.10 D9.10 ADJACENT TENANT EX T E R I O R EXTERIOR ADJACENT TENANT D23.10 D23.10 E21.02 E21.02 D26.25 D26.25 E50.65 E50.65E50.65 312 32 ' - 6 1 / 2 " A B C D D6.13 D22.00 D22.00 D22.00 D22.00 D22.00 D22.00 D22.00 E5.01 D8.07 D8.07 D8.07 MO T I F Y MO T I F Y MO T I F Y 9' - 9 1 / 2 " D6.13 D22.00 D6.13 D6.13 D22.00 D6.13 D22.00 D6.13 D22.00 8.07 8.07 8.07 8.07 8.07 E8.07 8.07 8.05 D6.13 D50.11 D50.11 D50.11 D50.11 D50.11 D50.12 D50.12 D50.12 D50.12 D22.13 50.63 D26.04 D22.08 D50.13 FOR FUTURE DOORDEMO OPENING 8.07 ADJACENT TENANT EX T E R I O R EXTERIOR ADJACENT TENANT D5.01 E5.01 312 (E)WALL TO REMAIN (E)ONE-HOUR WALL DEMO WALL DEMO FIXTURE DEMO ACT CEILING RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt DEMOLITION PLANS .AD101 1/4" = 1'-0"2DEMOLITION RCP 1/4" = 1'-0"1DEMOLITION FLOOR PLAN # DESCRIPTION 8.05 DOOR 8.07 STOREFRONT GLAZING 50.63 INFILL OPENING TO MATCH EXISTING, PLASTER TEXTURE AND COLOR D5.01 (E) COLUMN TO BE MODIFIED, SEE STRUCTURAL DWG D6.13 (E) CASEWORK TO BE REMOVED THROUGHOUT THE SPACE. D8.07 MODIFY (E) STOREFRONT GLAZING FOR NEW WORK D9.10 (E) SUSPENDED ACOUSTICAL CEILING TO BE REMOVED D9.11 (E) GYPSUM BOARD CEILING TO BE REMOVED D22.00 (E) PLUMBING FIXTURE TO BE REMOVED AND CAP ANY ABANDONED SERVICE/SANITARY LINES. D22.08 CAREFULLY REMOVE EXISTING WATER HEATER, WATER SOFTER AND FILTER AND RETURN TO THE LANDLORD FOR FUTURE REUSE. D22.13 (E) WASHER AND DRYER'S WATER AND DRAIN PIPES TO BE REMOVED AND CAP ANY ABANDONED SERVICE/SANITARY LINES. D23.10 (E) RETURN AIR GRILL AND DUCT TO BE REMOVED THROGHTOUT. D26.04 (E) ELECTRICAL PANEL TO BE REMOVED D26.25 (E) LIGHTING FIXTURE AND WIRE TO BE REMOVED THROGHOUT D50.11 (E) INTERIOR PARTITION TO BE REMOVED. SHOWN HIDDEN LINE. D50.12 (E) INTERIOR WALL FINISHES AND FLOOR FINISHES TO BE REMOVED THROUGHOUT. D50.13 REMOVE THE WALL OPENING FOR FUTURE DOOR. REFER TO FLOOR PLAN FOR MORE INFORMATION. E5.01 (E) STEEL COLUMN, SEE STRUCTURAL DWG E8.07 (E) STOREFRONT GLAZING E21.02 (E) FIRE SPRINKLER HEAD, MODIFY AS NEEDED FOR NEW WORK E50.65 EXISTING WALL TO REMAIN. KEY NOTE GENERAL NOTES 1 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXIST. FIELD CONDITIONS SO AS TO BECOME FAMILIARIZED WITH THE DEMOLITION AND / OR DEMOLITION WORK WHICH MAY BE REQUIRED TO PRODUCE RESULTS INTENDED IN THE CONTRACT DOCUMENTS. THE SCOPE OF WORK DESCRIBED IN THE CONTRACT DOCUMENTS ANTICIPATES THE DEMOLITION OF EXIST. CONSTRUCTION IN PART OR ITS ENTIRETY, AND THE DEMOLITION, RELOCATION AND POWERING OF CERTAIN CONSTRUCTION MATERIALS AND EQUIPMENT, INCLUDING ITEMS RELATED TO OTHER TENANTS WHICH MAY PASS THROUGH OR OCCUPY THIS TENANT'S SPACE. IT IS THE INTENT THAT EACH PORTION OF THE DEMOLITION AND REMODELING WORK BE DONE BY THE SPECIFIC TRADE INVOLVED IN THE INITIAL INSTALLATION, THAT IS - CARPENTRY WORK BY THE CARPENTRY TRADE, MECHANICAL AND ELECTRICAL WORK BY THE MECHANICAL AND ELECTRICAL TRADES RESPECTIVELY, AND SO ON. THEREFORE, EACH CONTRACTOR AND SUBCONTRACTOR SHALL THOROUGHLY EXAMINE THE PROPOSED WORK AND MAKE ALLOWANCES IN HIS PROPOSAL FOR THE COST OF ALL DEMOLITION AND/OR DEMOLITION WHICH MAY BE REQUIRED TO PRODUCE THE END RESULTS INTENDED BY THE CONTRACT DOCUMENTS. 2 IF THE GENERAL CONTRACTOR IS REQUIRED TO INSTALL A STOREFRONT BARRICADE DURING THE CONSTRUCTION PHASE OF THIS PROJECT, SUCH BARRICADE TO MEET THE LATEST BARRICADE DESIGN REQUIREMENTS OF THE LANDLORD, INCLUDING THE PAINTING OF SUCH BARRICADE AND ANY SIGNAGE ALLOWABLE BY LANDLORD AND UNDER LEASE OBLIGATION. 3 GENERAL CONTRACTOR TO COMPLETE ALL DEMOLITION AS NOTED IN CONTRACT DOCUMENTS AND REMOVE ALL DEBRIS AND RUBBISH FROM THE PROJECT AND BUILDING SITE. 4 DEMOLITION WORK WILL REQUIRE APPROVAL FROM THE LOCAL BUILDING DEPARTMENT, AND ALL INSURANCE PAPERS AS REQUIRED BY THE LANDLORD OF THE BUILDING TO BE SUBMITTED WITH THE REQUIRED LIMITS OF LIABILITY AND INDICATION OF INSURED PRIOR TO STARTING WORK. 5 ALL AREAS WHERE DEMOLITION IS TO OCCUR IS TO BE SECTIONED OFF FROM THE PUBLIC AND ALL REQUIRED SHORING, BARRICADING, AND SCAFFOLDING TO BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 6 ALL WORK TO BE IN ACCORDANCE WITH O.S.H.A. REQUIREMENTS. 7 ALL RUBBISH AND DEBRIS TO BE REMOVED FROM THE PROJECT SITE WITHIN A 24 HOUR PERIOD OR PLACED IN PRE-APPROVED DUMPSTER LOCATIONS; THIS CONTRACTOR TO RECEIVE APPROVAL OF DUMPSTER LOCATION FROM BUILDING LANDLORD REPRESENTATIVE. 8 ALL DEBRIS REMOVED FROM THE PROJECT SITE TO BE DUMPED IN ONLY APPROVED DUMPING SITE. ANY HAZARDOUS MATERIALS DEMOLITION OR DEBRIS DUMPING TO BE COMPLETED BY THIS CONTRACTOR, PER PROPER APPROVALS. 9 GENERAL CONTRACTOR TO CONTACT BUILDING LANDLORD REPRESENTATIVE AND ALL UTILITY COMPANY REPRESENTATIVES HAVING JURISDICTION OVER THIS PROJECT TO ASCERTAIN BUILDING AND UTILITY COMPANY LINES ABOVE, WITHIN, OR BELOW PREMISES TO AVOID ANY POSSIBILITIES OF CUTTING SUCH LINES, CAUSING EXPLOSIONS, ETC. 10 GENERAL CONTRACTOR IS RESPONSIBLE FOR THE BREAKOUT AND DEMOLITION OF CONCRETE SLAB AT ALL AREAS WHERE UNDER SLAB MECHANICAL, PLUMBING AND ELECTRICAL WORK OCCURS. REVIEW AND COORDINATE EXACT LOCATIONS AND SIZES WITH THE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS. NOTE: DO NOT CUT SLAB WITHOUT WRITTEN APPROVAL FROM LANDLORD 11 ALL WORK TO BE COMPLETED FOLLOWING LANDLORD'S CONSTRUCTION "RULES AND REGULATIONS". 12 DEMOLITION OR DEMOLITION REMOVAL TO BE COMPLETED IN A MANNER THAT THE "QUIET ENJOYMENT" OF ALL ADJACENT TENANTS OR THE BUILDING COMPLEX IS ADHERED TO AND THE OPERATION OF ADJACENT TENANTS OR THE BUILDING IS NOT HAMPERED IN ANY WAY. 13 PROTECTION OF ADJACENT TENANTS OR SPACES IS REQUIRED PRIOR TO ACTUAL DEMOLITION. 14 ALL CUTTING OF SERVICES OR UTILITIES AFFECTING THE BUILDING COMPLEX OR ADJACENT TENANTS INCLUDING SPRINKLER OPERATION TO BE COMPLETED ON "OFF HOURS". 15 ALL ELECTRICAL DEMOLITION TO BE COMPLETED BY A BONDED LICENSED ELECTRICIAN. THE ELECTRICAL CONTRACTOR SHALL REMOVE AND/OR RELOCATE ALL EXIST. ELECTRICAL DEVICES, CONDUIT AND WIRING WORK AS CALLED OUT IN THE CONTRACT DOCUMENTS AND AS NECESSARY WHETHER SUCH ITEMS ARE INDICATED IN THE CONTRACT DOCUMENTS OR NOT,IN ORDER TO ACCOMPLISH THE INSTALLATION OF THE SPECIFIED NEW WORK EQUIPMENT. MATERIAL AND DEVICES REMOVED SHALL BECOME THE PROPERTY OF CONTRACTOR (IF APPROVED BY THE TENANT). SUCH ITEMS MAY ONLY BE REUSED IF SPECIFICALLY DESIGNATED IN THE CONTRACT DOCUMENTS. CONDUIT, WIRE AND OUTLET BOXES REMOVED SHALL BE SCRAPPED BY THE ELECTRICAL CONTRACTOR. WHERE WALLS AND CEILING ARE TO BE REMOVED, THE CONDUIT IS TO BE CUT OFF BY THE ELECTRICAL CONTRACTOR SO THAT THE ABANDONED CONDUIT IN THESE WALLS AND CEILINGS MAY BE REMOVED WITH THE WALLS AND CEILINGS BY THE DEMOLITION CONTRACTOR. ALL DEAD END CONDUIT RUNS SHALL BE PLUGGED AT THE REMAINING LINE OUTLET BOXES OR AT THE PANELS, IF NOT COMPLETELY REMOVED. 16 ALL PLUMBING DEMOLITION TO BE COMPLETED BY A BONDED LICENSED PLUMBER. PLUMBING SUBCONTRACTOR TO VISIT SITE PRIOR TO BIDDING ON DEMOLITION, LOCATE ALL SUPPLY, WASTE AND VENT PIPING TO BE REMOVED, LABEL ALL SUPPLY, WASTE AND VENT PIPING TO REMAIN, COORDINATE WITH LANDLORD AS TO ALL CONCRETE CUTTING OF SLABS WHICH WILL BE COMPLETED BY LANDLORD'S G.C., CAP BELOW SLAB LINES AS REQUIRED, BRING UP TO SLAB LINES ALL PIPES THAT ARE TO BE CREATED FOR CODE REQUIRED CLEAN-OUTS AND FOR ALL NEW CLEAN-OUTS. COORDINATE WITH GENERAL CONTRACTOR AND 17 DEMOLITION WORK TO BE PHASED TO ALLOW PROPER EGRESS FOR ANY PERSON IN CASE OF FIRE OR HAZARD AND NO DEMOLITION WORK CAN OCCUR IF THE WORK JEOPARDIZES A MEANS OF EGRESS FOR THE PUBLIC OR PROJECT EMPLOYEES 18 REMOVE EXIST. GYPSUM BOARD AND ACOUSTICAL TILE CEILINGS. 19 ALL LABOR TO BE COMPATIBLE WITH OTHER LABOR COMPLETING WORK IN THE BUILDING. 20 ALL PARTITIONING AND FINISHES TO BE REMOVED, UNLESS NOTED OTHERWISE, EXIST. FURRED WALLS AROUND PERIMETER TO BE REMOVED AS NOTED. 21 ALL SPRINKLER LINES, MAINS, BRANCHES, AND HEADS TO REMAIN OR TO BE MODIFIED, RAISED, REPOSITIONED BY THE GENERAL CONTRACTOR'S SPRINKLER CONTRACTOR, OR LANDLORDS DESIGNATED SPRINKLER CONTRACTOR (GENERAL CONTRACTOR TO VERIFY PRIOR TO BID) 22 REMOVE PLUMBING FIXTURES SHOWN TO BE REMOVED AND ALL THEIR ASSOCIATED PIPES. REPAIR ALL PENETRATIONS THROUGH WALLS, ROOF AND FLOOR TO ACHIEVE A LEVELED SMOOTH FINISH WITH ADJACENT MATERIALS. 23 ALL ELECTRICAL WIRING AND FIXTURES TO BE REMOVED AND THE MAIN ELECTRICAL SERVICE TO BE EXTENDED AND RELOCATED BY THE GENERAL CONTRACTOR INCLUDING SERVICE CONDUIT AND WIRE, WITH ALL NEW TRANSFORMER(S), DISCONNECTS(S), TROUGHS, PANELS, ETC. TO MAKE UP TENANT'S NEW ELECTRICAL DISTRIBUTION AREA, AS INDICATED ON THE CONTRACT DOCUMENTS 24 REUSE EXIST. ROOF SUPPORTS AND OPENINGS TO THE FULLEST EXTENT POSSIBLE AND PATCH AND REPAIR AS REQUIRED, AND AS INDICATED ON MECHANICAL DRAWINGS. 25 ALL EXIST. UTILITIES WITHIN LEASE LINES TO BE RAISED AND MODIFIED AS REQUIRED, INCLUDING SPRINKLER MAIN, TO ALLOW FOR TENANT'S DESIGN ELEMENTS. LEGEND FOR FLOOR DRAIN & FLOOR SINK LOCATION. REFER TO SHEET A101 & P03. REFER TO 2/AD102 FOR SLAB INFILL DETAIL FOR FLOOR OUTLET LOCATION. REFER TO SHEET E1.0 NOTE: NO SHEAR OR BEARING WALLS ARE REMOVED. NOTE: REBAR CAN BE INSTALLED AT AN ANGLE & BENT ONCE IN FIELD (2) #4 CONTINUOUS (N) MIN 3000 PSI CONCRETE (E) SLAB ON GRADE COMPACT SOIL UNDER (N) SLAB TRENCH AS REQ'D. FOR PLUMBING DRILL & EPOXY #4 DOWELS @ 18" O.C. W/ HILTI RE-500 V3 (ESR-3814) W/ 4" EMBED. ROUGHEN (E) SLAB TO 1/4" AMPLITUDE MIN. PROVIDE 15 MILL VAPOR BARRIOR AT TRENCH A B C D E70.10 E70.10 E70.10 E70.10 E70.11 7.36 7.36 7.36 7.367.36 7.36 7.36 312 1/4" = 1'-0"1DEMOLITION ROOF PLAN RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt DEMOLITION PLANS .AD102 # DESCRIPTION 7.36 FUTURE RTU AND VENT ROOF OPENING.REFER TO ROOF PLAN, MECHANICAL AND PLUMBING DRAWING FOR MORE INFORMATION. E70.10 (E) MECH EQUIPMENT, REPAIR AS NEEDED. GC TO VERIFY IN FIELD E70.11 (E) EXISTING ROOF TO REMAIN KEY NOTE GENERAL NOTES 1" = 1'-0"2SLAB INFILL DETAIL WH ROOM FINISH NOTES: 1. REFER TO CEILING PLAN FOR CEILING HEIGHT VARIATIONS & SOFFIT DETAILS. 2. PROVIDE WONDERBOARD OVER PLYWOOD AS NEEDED FOR CERAMIC TILE. 3. EXPOSED CONCRETE TO RECEIVE HARDENER & CLEAR SEALER. (SEALER TO BE APPROVED BY LOCAL HEALTH DEPT.) 4. ACOUSTICAL PANELS TO HAVE FACTORY FINISH WASHABLE SURFACE. APPROVED BY LOCAL HEALTH DEPARTMENT. 5. GYP. BOARD AT WALLS TO BE MOISTURE RESISTANT. 6. CIRCULATION PATHS OF THE MEANS OF EGRESS SHALL HAVE A SLIP-RESISTANT SURFACE AND BE SECURELY ATTACHED AND COMPLY WITH CBC 11B-302.1. 7. INSTALL 8' MIN. FRP AT WALL IN THE KITCHEN AREA BEHIND THE WALL WHERE ALL THE SINKS AREA LOCATED. 8. WALL FINISH BEHIND AND AROUND THE COOKING EQUIPMENT WILL BE STAINLESS STEEL OR A CERAMIC TILE. NO FRP SHOULD BE INSTALLED BEHIND AND AROUND THE COOKING EQUIPMENT. INTERIOR FINISH GENERAL NOTES: A. INTERIOR FINISH MATERIALS APPLIED TO WALLS & CEILING SHALL HAVE A MAXIMUM SPREAD CLASSIFICATION OF II FOR EXIT CORRIDORS & III FOR OTHER ROOMS OR AREAS. 94 U.B.C. Chap. 8, Table 8-A. B. ALL PIPING AND REFRIGERATION COILS IN PREPARATION AREAS TO BE CONCEALED & AS INDICATED ON PLUMBING & REFRIGERATION DRAWINGS, TYPICAL. C. ALL GYP. BOARD TO BE TAPED & SPACKLED. EXCEPT AS NOTED FTO. D. DOOR SWINGS INTO EXIT CORRIDOR SHALL NOT REDUCE THE REQUIRED 44" CLEAR WIDTH BY MORE THAN HALF (U.B.C. Section 1005.4). E. ALL SERVICE AND RETAIL AREA WALLS, DRYWALL SOFFITS, CURTAIN WALLS & DRYWALL CEILINGS (EXCEPT T-BAR CEILINGS) SHALL BE PAINTED WITH WHITE S.G.E. FINISH PAINT ABOVE FIXTURE LINE & ABOVE WHERE F.R.P. OCCURS F. A TROWELED-ON, WATERPROOF MEMBRANE ON RESTROOM FLOOR SLABS AND WHERE WATER OR OTHER LIQUIDS ARE USED G. FRP (WHITE) FOR WALLS OF STORAGE ROOM & FOOD PREPARATION AREA F.R.P. TO BE 8' MIN. HEIGHT. H. QUARRY TILE USE DALTILE 6" x 6" x 1/4" OR EQUAL. USE 6" x 4" FOR COVE BASE I. T-BAR CEILING IN FOOD PREPARATION AREA, CHANGE ROOM & RESTROOM USE USG WASHABLE SURFACE VINYL TILE, USG STIPPLE WHITE #3270 J. ALL PAINT, TILES, F.R.P. ON THE WALLS & CEILING SURFACE USE LIGHT COLOR WITH "SMOOTH & NO TEXTURE" IN THE FOOD PREPARATION AREA, RESTROOM & CHANGE AREA. K. WALLS BEHIND COOKING EQUIPMENTS SHALL BE STAINLESS STELL. L. ALL FLOOR AND CEILING FINISHES TO BE SMOOTH AND WASHABLE M. BASE COVE WILL HAVE A 3/8-INCH RADIUS COVE EXTENDING AT LEAST 4 INCHES HIGH AND INTEGRAL WILL THE FLOOR. FINISH SCHEDULE LEGEND: (GC SHOULD SUBMIT FINISHES MATERIAL FOR REVIEW) FLOOR EPOXY 1 STONE COAT GREYSTONE COLLECTION: OPAL FLAKE EPOXY 2 POLY-CRETE HF -COLOR CONCRETE GREY PTILE DALTILE PORCELAIN TILE MEDIAN (12"X24") LIGHT GRAY MN43 PSS PREFABRICATED SMOOTH S/S FLOOR DL BASE EPOXY 1 STONE COAT GREYSTONE COLLECTION: OPAL FLAKE -4" HIGH WITH 3/4" RADIUS CONTINUOUS COVE BASE EPOXY 2 POLY-CRETE HF -COLOR CONCRETE GREY -4" HIGH WITH 3/4" RADIUS CONTINUOUS COVE BASE PTILE DALTILE PORCELAIN TILE MEDIAN (6"X12") LIGHT GRAY MN43 COVED BASE -6" HIGH WITH 3/8" RADIUS CONTINUOUS COVE BASE SS 6”STAINLESS STEEL COVE BASE WALL PT PAINT (WHITE) TILE CERAMIC WALL TILE (LIGHT GREEN) QT QUARRY TILE (24"X24") (WHITE) FRP FIBERGLASS REINFORCED PLASTIC PANEL (WHITE) SST STAINLESS STEEL WALL PANEL CTILE DALTILE GLACIER WHITE: A 12" X 12" GLAZED CERAMIC FLOOR SS SMOOTH STAINLESS STEEL CEILING (REFER TO SHEET A102 FOR MORE INFORMATION) GYP BD PAINTED GYP ACT ACOUSTICAL CEILING TILE. ACOUSTICAL CEILING TILE FINISH TILE: ARMSTRONG LUMAWASH SMOOTH, BRIGHT WHITE FINISH SS SMOOTH STAINLESS STEEL CEILING 1. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL CONDUITS, GRIDERS, BEAMS AND REINFORCING PRIOR TO CORE DRILLING FLOOR OR CUTTING OPENINGS IN EXISTING FLOOR AND/OR ROOF. NOTIFY ARCHITECT OF ANY CONFLICTS BETWEEN EXISTING INFRASTRUCTURE AND PROPOSED WORK PRIOR TO PROCEEDING WITH IMPROVEMENTS. 2. INTERIOR PARTITION TYPES AND DETAILS, SEE SHEET A510 & A511. 3. DOOR SCHEDULE, SEE SHEET A601. FOR REFLECTED CEILING PLAN (RCP) 1. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AND INDICATED ON DRAWINGS. FOR ALL CEILING FINISHES, PLUMBING , FIRE SPRINKLER, MECHANICAL AND ELECTRCIAL SYSTEMS. 2. EXIT SIGNS, WHERE NOTED, SHALL BE WORDED "EXIT" IN LETTERS SIX INCHES (6") HIGH. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES AND PROVIDED WITH AN EMERGENCY ELECTRICAL SYSTEM FROM STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON-SITE GENERATOR SET TO INSURE CONTINUED ILLUMINATION FOR AT LEAST 90 MINUTES IN CASE OF PRIMARY POWER LOSS. 3. INTERNALLY ILLUMINATED EXIT SIGNS -ELECTRICALLY POWERED, SELF-LUMINOUS AND PHOTOLUMNESCENT EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND (CBC) CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. 4. ADDITIONAL DIRECTIONAL EXIT SIGNAGE MAY BE REQUIRED BY THE COVERING AGENCY HAVING JURISDICTION OVER THE PROJECT AT THE TIME OF FINAL INSPECTION. A405 2 30 " x 4 8 " 30"x48" 30 " x 4 8 " C L R ø 5 ' - 0 " FD30"x48" CLR ø 5' - 0"30"x48" 14' - 5" 20 ' - 5 1 / 2 " 11 ' - 1 1 1 / 2 " 4' - 0" HO L D 4' - 2 1 / 2 " A401 3 4 2 1 A403 7 A403 65 A B C D 31 ' - 7 " 32 ' - 6 1 / 2 " 38 ' - 2 " A404 54 A4041 A4031 3 6.15 11.55 11.54 616 SF KITCHEN 6 241 SF OFFICE/STORAGE 12 65 SF TOILET 10 64 SF TOILET 11 234 SF SUSHI PREP. AREA 7 100 SF SEATING 2 245 SF WAITING 3 247 SF ENTRY LOBBY 1 823 SF RETAIL 9 289 SF POP-UP 13 151 SF SERVICE COUNTER 5 4' C L E A R 4' - 0 " 21' - 6 1/2" E01 0706 08 05 11.54 11.55 CLR ø 5' - 0" 50.11 22.08 26.04 FD 8.05 A4021 2 A403 8 177 SF GRAM BAR 4 3 A301 3 A301 4 A301 4 A301 1 A301 1 A301 2 A301 2 A301 4 21 ' - 1 0 " 3 2 01 02 03 04 Cooler Freezer 2 4 A404 6 A404 3 1' - 0 1 / 2 " CL E A R 8' - 4 1 / 2 " 7' - 9 1/2"7' - 7"6' - 2" +/ - 1 1 ' - 8 " 12 ' - 2 1 / 2 " 2' - 1 0 1 / 2 " 26 ' - 2 1 / 2 " 8' - 5 1/2"9' - 4 1/2"9' - 8 1/2" 9' - 5" HOLD 2' - 0" OPENING 3' - 0" 21 " 39 " 99 " 9" 18 9 " GLASS 4' - 0" ADJACENT TENANT EX T E R I O R EXTERIOR ADJACENT TENANT A701 1 A4039 1' - 6" 44 " C L E A R 3' - 9 " 2' - 6"+/- 4' - 0"2' - 8"9' - 10" CLEAR 9' - 5" 42 " L O W W A L L 3 4 " L O W W A L L 3' - 7" FD FD FD FD FS FS (V . I . F ) (E ) 7 1 / 2 " (E ) 1 ' - 1 " 5' - 0 " 2' - 6 1/2" 3' - 2 " 27 ' - 0 1 / 2 " ALIGN 6' - 7 " 8' - 4 " 5' - 4" 1' - 6" 2' - 10 1/2" E8.05 8.05 8.05 6.14 22.19 22.18 22.18 22.19 22.18 22.18 26.27 6.14 26.27 11.56 11.02 23.06 FH4 PH4A PH4A FH4A FH4AFH4A FF4 FF4 FH4 FH4 PH4 FH4 PH4 FF4 E5.01 5.01 E50.65 E50.65 E50.65 50.11 FD 11.52 11.56 8.05 34 " H I G H C H E C K O U T CO U N T E R 34 " H I G H C H E C K O U T CO U N T E R PH4 FH4 LH4 PW4 36 " H I G H C O U N T E R 38 " H I G H C O U N T E R 42 " H I G H CO U N T E R 34 " C O U N T E R LH4 09 30 " x 4 8 " 30 " x 4 8 " 50.07 11.02 WALK-IN FRIDGE 8 50.07 50.07 50.07 6' - 1 " 5' - 1 1 " FS 3' - 0 " 8' - 2 1/2" 22.18 22.18 22.18 10.42 WA L K O F F M A T T W A L K O F F M A T T WA L K O F F M A T T 26.04 22.40 22.40 22.41 22.40 22.41 22.40 22.41 22.40 22.41 22.40 22.40 26.28 FD 50.63 50.63 16' - 0" 11 " 23 " 13 2 " 2' - 8"10.03 10.03 E5.01 1' - 9 " 4' - 0" 4' - 0" 34 " HI G H 38 " C O U N T E R 30 " x 4 8 " C L R ø 5 ' - 0 "CLR ø 5' - 0" 30"x48" 30"x48" 60" CLEAR 5' - 6 1/2" 30 " x 4 8 " 312 13 ' - 4 1 / 2 " 12 ' - 1 " (E)WALL TO REMAIN (E)ONE-HOUR WALL FH FH (N)PARTITION ONE-HOUR WALL PARTITION TYPE (N)WALL INFILL PARTITION TYPE INSULATED WALL (N) RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt FLOOR PLAN A101 KEY NOTE # DESCRIPTION 5.01 STEEL COLUMN. REFER TO STRUCTURAL DRAWING FOR MORE INFORMATION 6.14 SOLID SURFACE COUNTER TOP 6.15 WOOD FINISH COUNTER TOP WITH FLOATING COUNTERTOP WALL BRACKET @ MAX. 4'-0" O.C. 8.05 DOOR 10.03 TENANT SIGNAGE(PROVIDE POWER). GC TO PROVIDE BACKING FOR THE SIGN AS REQUIRED. 10.42 SIX-TIER LOCKERS 11.02 COLD DISPLAY CASE. SEE FS101-EQUIPMENT SHEET AND ELEC DWG. FOR MORE INFO. 11.52 LED WALL PANEL. GC TO PROVIDE POWER AND WALL BACKING FOR THE LED PANEL. REFER TO ELEC DWG FOR MORE DETAIL INFORMATION. 11.54 P.O.S. SYSTEM, SEE EQUIPMENT PLAN 11.55 DIGITAL KIOSK, SEE EQUIPMENT PLAN 11.56 RETAIL SHELVING, SEE EQUIPMENT PLAN 22.08 WATER HEATER 22.18 FLOOR DRAIN (SEE PLUMBING DRAWING) 22.19 FLOOR SINK (SEE PLUMBING DRAWING) 22.40 PLUMBING FIXTURES-REFER TO EQUIPMENT SCHEDULE AND PLUMBING DRAWING 22.41 ACCESSIBLE SINK-REFER TO EQUIPMENT SCHEDULE AND PLUMBING DRAWINGS. PROVIDE LEVER-HANDLE FAUCET CONTROLS. SEE ACCESSIBLE SINK DETAIL FOR REQUIRED FLOOR CLEARANCE AND MOUNTING HEIGHT ON SHEET A101. 23.06 KITCHEN EXHAUST HOOD, SEE MECHANICAL DRAWING 26.04 ELECTRICAL PANEL, SEE ELEC. DWG 26.27 LED TAPE LIGHT FIXTURE BELOW COUNTERTOP, SEE ELEC DWG 26.28 LED TAPE LIGHT FIXTURE AT CASEWORK BASE, SEE ELEC DWG 50.07 LINE OF SOFFIT ABOVE 50.11 INTERIOR PARTITION 50.63 INFILL OPENING TO MATCH EXISTING, PLASTER TEXTURE AND COLOR E5.01 (E) STEEL COLUMN, SEE STRUCTURAL DWG E8.05 (E) DOOR E50.65 EXISTING WALL TO REMAIN. GENERAL NOTESFINISH SCHEDULE ROOM NUMBER NAME CEILING FINISH FLOOR FINISH BASE WALL FINISH NOTENORTH EAST SOUTH WEST 1 ENTRY LOBBY C-3 EXPOSED EPOXY 1 EXPOXY1 PT PT PT PT 1/A406 2 SEATING C-3 EXPOSED EPOXY 1 EXPOXY1 PT PT PT PT 1/A406 3 WAITING C-3 EXPOSED EPOXY 1 EXPOXY1 PT PT PT PT 3/A406 4 GRAM BAR C-1 GYP BD EPOXY 2 EXPOXY2 SST SST SST N/A 5/A406 5 SERVICE COUNTER C-1 GYP BD EPOXY2 EXPOXY2 TILE TILE TILE TILE 3/A406 6 KITCHEN C-2 ACT EPOXY2 EXPOXY2 PT SST FRP/P FRP/PT 4.5/A406. SEE ELEVATION FOR MORE DETAIL 7 SUSHI PREP. AREA C-2 ACT EPOXY2 EXPOXY2 QT QT QT QT 3/A406 8 WALK-IN FRIDGE SS PSS/EPOXY2 SS SS SS SS SS SS FLOOR AT FREEZER AREA. REFER TO FRIDGE SHOP DRAWING 9 RETAIL C-3 EXPOSED EPOXY1 EXPOXY1 PT PT PT PT 1/A406 10 TOILET C-1 GYP BD PTILE PTILE CTILE CTILE CTILE CTILE 2/A406 11 TOILET C-1 GYP BD PTILE PTILE CTILE CTILE CTILE CTILE 2/A406 12 OFFICE/STORAGE C-2 ACT EPOXY1 EXPOXY1 PT PT PT PT 1/A406 13 POP-UP C-3 EXPOSED EPOXY1 EXPOXY1 PT PT PT PT 1/A406 1/4" = 1'-0"1FLOOR PLAN WALL TYPE -REFER TO SHEET A511 DOOR TYPE -REFER TO SHEET A601 FLOOR PLAN LEGEND NOTE : REFER TO FS 101 SHEET FOR EQUIPMENT PLAN AND SCHEDULE WALL LEGEND ADA DOOR MANEUVERING CLEARANCES GREEN BUILDING NOTE: 1. VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS (ARCHITECTURAL PAINTS) SHALL COMPLY WITH CGBC TABLE 5.504.4.3, UNLESS MORE STRINGENT LOCAL LIMITS APPLY. [CGBC 5.504.4.3] . REFER TO SHEET G301C 2. WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES, AND OPERABLE WINDOWS AND IN BUILDINGS. MEET ADDITIONAL AND MORE STRINGENT REQUIREMENTS IN APPLICABLE ORDINANCES, REGULATIONS, AND POLICIES. [CGBC 5.504.7] . ACCESSIBILITY SINK DETAILS NOTE: ADDITIONS AND ALTERATIONS TO EXISTING BUILDINGS OR FACILITIES SHALL COMPLY WITH SECTION 11B-202. 1. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL CONDUITS, GRIDERS, BEAMS AND REINFORCING PRIOR TO CORE DRILLING FLOOR OR CUTTING OPENINGS IN EXISTING FLOOR AND/OR ROOF. NOTIFY ARCHITECT OF ANY CONFLICTS BETWEEN EXISTING INFRASTRUCTURE AND PROPOSED WORK PRIOR TO PROCEEDING WITH IMPROVEMENTS. 2. INTERIOR PARTITION TYPES AND DETAILS, SEE SHEET A510 & A511. 3. DOOR SCHEDULE, SEE SHEET A601. FOR REFLECTED CEILING PLAN (RCP) 1. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AND INDICATED ON DRAWINGS. FOR ALL CEILING FINISHES, PLUMBING , FIRE SPRINKLER, MECHANICAL AND ELECTRCIAL SYSTEMS. 2. EXIT SIGNS, WHERE NOTED, SHALL BE WORDED "EXIT" IN LETTERS SIX INCHES (6") HIGH. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES AND PROVIDED WITH AN EMERGENCY ELECTRICAL SYSTEM FROM STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON-SITE GENERATOR SET TO INSURE CONTINUED ILLUMINATION FOR AT LEAST 90 MINUTES IN CASE OF PRIMARY POWER LOSS. 3. INTERNALLY ILLUMINATED EXIT SIGNS -ELECTRICALLY POWERED, SELF-LUMINOUS AND PHOTOLUMNESCENT EXIT SIGNS SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 924 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND (CBC) CHAPTER 27. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. 4. ADDITIONAL DIRECTIONAL EXIT SIGNAGE MAY BE REQUIRED BY THE COVERING AGENCY HAVING JURISDICTION OVER THE PROJECT AT THE TIME OF FINAL INSPECTION. A B C D EQ EQ EQ EQ 2' - 7 " 3' - 4 " 2' - 7 " 3' - 4 " 3' - 0"2' - 7"12' - 2" C2 9' - 0" C1 9' - 0" C1 9' - 0" C1 9' - 0" 2' - 5 1/2" 2' - 8"2' - 8" 2' - 7 " C2 9' - 0" 26.25 LT-4 LT-5 LT-4 LT-4 LT-4 LT-5 23.06 60.02 1' - 2" 2' - 11"1' - 9" 4' - 0 " 4' - 0 " 3' - 0 " LT-4 C1 9' - 0" C2 9' - 0" C1 9' - 0" LT-4 LT-2 LT-2 LT-2 LT-2 3' - 0" LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1LT-1LT-1 LT-1 11 ' - 7 " LT-6 LT-6 OPEN 2' - 10 1/2" EQ 3' - 6"3' - 6"EQ 12 ' - 0 " 1' - 5 1 / 2 " 8' - 0 " 1' - 9 " 12 ' - 0 " 3' - 0 " 14 ' - 0 " 1' - 2"2' - 11"9" 5' - 10" 6" 3' - 0"0' - 0" 2' - 1 0 1 / 2 " 2' - 2 1 / 2 " 8' - 5 " C-3 OPEN C-3 8' - 1" 2' - 11"5' - 1"2' - 3 1/2" 24' - 0" 1' - 11" ADJACENT TENANT EX T E R I O R EXTERIOR ADJACENT TENANT EX T E R I O R 3' - 6"3' - 6"3' - 6"3' - 0"3' - 6" 1' - 1 0 " 4' - 0 " 4' - 0 " 3' - 0 " 1' - 0 " C1 9' - 0" LT-4.1 LT-4 LT-4 2' - 3 " LT-2 LT-2 23.06 2 A102 2 A102 3 A102 4 A102 10.51 10.51 10.51 23.11 60.03 23.11 23.11 26.52 26.52 26.52 26.52 23.11 23.11 23.11 23.11 26.52 1' - 0" 3 A102 5 A102 9' - 0" OPEN C-3 6 A102 4 A102 SOFFIT 5' - 1 " 24' - 0" 2' - 1 1 " 14 ' - 0 " 3' - 2 " 3' - 10 1/2"3' - 6" KITCHEN 6 OFFICE/STORAGE 12 TOILET 10 TOILET 11 SUSHI PREP. AREA 7 SEATING 2 WAITING 3 ENTRY LOBBY 1 RETAIL 9 POP-UP 13 SERVICE COUNTER 5 GRAM BAR 4 WALK-IN FRIDGE 8 7 A102 EQ 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " 4' - 0 " EQ .. . 312 EQ EQ EQ EQ DESCRIPTIONTYPE LIGHTING FIXTURE LEGEND SYMBOL LT-1 LT-2 LT-4 LT-4.1 LT-5 LT-6 LINEAR UP LED WALL WASHER LIGHTS - WHITE FINISH 2'X2' LED RECESSED LIGHT FIXTURE - WHITE FINISH SUSPENDED TRACK LIGHT - BLACK FINISH 4" RECESSED DOWN LIGHT - WHITE FINISH SUSPENDED LINEAR LIGHT - BLACK FINISH RECESSED DIRECTIONAL DOWNING - WHITE FINISH REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION AND ELEVATION FOR SUSPENDED FIXTURE MOUNTING HEIGHT 5/8" GYP BOARD 3 5/8 X 20GA @ 32" O.C. DIAGONAL BRACING ATTACHED TO THE STRUCTURAL ABOVE CEILING HIGH REFER TO CEILING PLAN 3 5/8"X 20GA @16 O.C. METAL STUD FRAMING ATTACHED TO THE STRUCTURAL ABOVE 5/8" GYP BOARD TRACK (MATCH STUD GAUGE & SIZE) SECURE TO STUDS WITH #8 S.M.S. EACH SIDE (3) #8 S.M.S. SUSPENDED GYP. BD. CEILING A511 9A511 8 5/8" GYP BOARD 3 5/8 X 20GA @ 32" O.C. DIAGONAL BRACING ATTACHED TO THE STRUCTURAL ABOVE CEILING HIGH REFER TO CEILING PLAN 3 5/8"X 20GA @16 O.C. METAL STUD FRAMING ATTACHED TO THE STRUCTURAL ABOVE 5/8" GYP BOARD TRACK (MATCH STUD GAUGE & SIZE) SECURE TO STUDS WITH #8 S.M.S. EACH SIDE (3) #8 S.M.S. SUSPENDED GYP. BD. CEILING 6" WOOD FINISH WOOD FINISH PAINT BLACK (MATTE) A511 9 A511 8 5/8" GYP BOARD 3 5/8 X 20GA @ 32" O.C. DIAGONAL BRACING ATTACHED TO THE STRUCTURAL ABOVE CEILING HIGH REFER TO CEILING PLAN 3 5/8"X 20GA @16 O.C. METAL STUD FRAMING ATTACHED TO THE STRUCTURAL ABOVE 5/8" GYP BOARD TRACK (MATCH STUD GAUGE & SIZE) SECURE TO STUDS WITH #8 S.M.S. EACH SIDE (3) #8 S.M.S. SUSPENDED GYP. BD. CEILING 4" 4" 3/4" FT. PLY WOOD LIGHT FIXTURE. SEE ELECTRICAL DWG BLOCKING A511 9A511 8 5/8" GYP BOARD 3 5/8 X 20GA @ 32" O.C. DIAGONAL BRACING ATTACHED TO THE STRUCTURAL ABOVE CEILING HIGH REFER TO CEILING PLAN 3 5/8"X 20GA @16 O.C. METAL STUD FRAMING ATTACHED TO THE STRUCTURAL ABOVE 5/8" GYP BOARD, PAINT BLACK (MATTE) TRACK (MATCH STUD GAUGE & SIZE) SECURE TO STUDS WITH #8 S.M.S. EACH SIDE (3) #8 S.M.S. SUSPENDED GYP. BD. CEILING 6" WOOD FINISH WOOD FINISH 1' - 0" (2) #10 S.M.S. AT EACH (E) STUD (E) WALL A511 9 A511 8 3 5/8 X 20GA @ 48" O.C. DIAGONAL BRACING ATTACHED TO THE STRUCTURAL ABOVE CEILING HIGH REFER TO CEILING PLAN 3 5/8"X 20GA @16 O.C. METAL STUD FRAMING ATTACHED TO THE STRUCTURAL ABOVE 5/8" GYP BOARD PAINTED WHITE TRACK (MATCH STUD GAUGE & SIZE) SECURE TO STUDS WITH #8 S.M.S. EACH SIDE (3) #8 S.M.S. PAINT BLACK (MATTE) 1' - 6 " 16" GA METAL BEND PLATE BLACK GLASS STOREFRONT 2" 4 1/2" SEALED A511 9 A511 8 5/8" GYP BOARD 3 5/8 X 20GA @ 32" O.C. DIAGONAL BRACING ATTACHED TO THE STRUCTURAL ABOVE CEILING HIGH REFER TO CEILING PLAN 3 5/8"X 20GA @16 O.C. METAL STUD FRAMING ATTACHED TO THE STRUCTURAL ABOVE 5/8" GYP BOARD TRACK (MATCH STUD GAUGE & SIZE) SECURE TO STUDS WITH #8 S.M.S. EACH SIDE (3) #8 S.M.S. SUSPENDED GYP. BD. CEILING A511 9A511 8 6" WALK-IN FRIDGE SOFFIT HIGH REFER TO CEILING PLAN RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt REFLECTED CEILING PLAN A102 KEY NOTE # DESCRIPTION 10.51 ILLUMINATED EXIT SIGN, SEE ELEC DWG 23.06 KITCHEN EXHAUST HOOD, SEE MECHANICAL DRAWING 23.11 NEW MECHANICAL DUCTWORK, SEE MECH DWG" 26.25 LIGHTING FIXTURE, SEE ELEC. DWG 26.52 EMERGENCY LIGHTING 60.02 EXPOSED CEILING, PAINT ALL EXPOSED ITEMS TO BLACK U.N.O. 60.03 GYM. BD. SOFFIT WITH LED COVE LIGHT ABOVE, SEE ELEC. DWG GENERAL NOTES 1/4" = 1'-0"1REFLECTED CEILING PLAN CEILING TYPE C-1 SUSPENDED 5/8" GYP BD CEILING SYSTEM C-2 24"X24" ACOUSTICAL CEILING TILE FINISH TILE:ARMSTRONG KITCHEN ZONE SMOOTH, BRIGHT WHITE FINISH -REFER TO SHEET A515 C-3 EXPOSED STRUCTURE ABOVE TO REMAIN. PAINTED DECK-(BLACK), SOFFIT - (WHITE), BEAM- (WHITE) C-4 WALK IN FRIDGE SMOOTH STAINLESS STEEL CEILING FIXTURE LEGEND 1 1/2" = 1'-0"2SOFFIT SECTION 1 1/2" = 1'-0"3 SOFFIT SECTION- LIGHT COVE 1 1/2" = 1'-0"4 SOFFIT SECTION - RETAIL COUNTER 1 1/2" = 1'-0"5SOFFIT DETAIL 1 1/2" = 1'-0"6SOFFIT DETAIL 1 1/2" = 1'-0"7SOFFIT DETAIL NOTE: INSTALL AND RUN DUCTWORK WITHIN THE OPEN CEILING AREA, EITHER BETWEEN THE OPENINGS OF THE WEB JOISTS OR TIGHT TO THE BOTTOM OF THE TJI BEAMS. THE DUCTWORK IN OPEN CEILING AREAS SHALL BE LOCATED ABOVE THE LIGHTING FIXTURES. PAINT ALL EXPOSED DUCTWORK TO MATCH THE ROOF DECK COLOR. A B C D E70.10 E70.10 E70.10 23.04 23.04 23.01 E70.10 23.02 23.02 FR E E Z E R CO O L E R 21 6 L B 23 4 L B 23.13 23.13 23.11 19 ' - 0 " 19' - 10 1/2" 28' - 1" 5' - 6 " 7' - 1 1 " 15' - 8"15' - 11 1/2" 1' - 7 1 / 2 " 7' - 1 " 312 RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt ROOF PLAN A103 KEY NOTE # DESCRIPTION 23.01 MAKE UP AIR UNIT: PROVIDE CURBED ROOF OPENING, SEE MECH DWG AND STRUCTURAL DWG 23.02 CONDENSER UNIT. 23.04 EXHAUST FAN: PROVIDE CURBED ROOF OPENING. SEE MECH DWG AND STRUCTURAL DWG 23.11 NEW MECHANICAL DUCTWORK, SEE MECH DWG" 23.13 SUPPLY AIR DIFFUSER, SEE MECH DWG E70.10 (E) MECH EQUIPMENT, REPAIR AS NEEDED. GC TO VERIFY IN FIELD GENERAL NOTES 1/4" = 1'-0"1ROOF PLAN 1. GC TO MAINTAIN ALL THE WATERPROOFING FOR THE ROOFING AT PENETRATION AREA.NOTE: 1. REFER TO SHEET AS101 SITE PLAN FOR ROOF ACCESS LADDER LCOATION 2. REFER TO MECHANICAL AND PLUMBING DRAWING FOR REFER TO RTU AND VENT ROOF OPENING. FINISH FLOOR 0' -0" CEILING 9' -0" T.O.P. 24' -0" BCD LO W W A L L 3' - 6 " GL A S S 5' - 6 " POP-UP 13 RETAIL 9 WAITING 3 GRAM BAR 4 BO T T O M O F L I G H T T R A C K 9' - 6 " 9' - 0 " HI G H C O U N T E R 3' - 6 " CO U N T E R B E Y O N D 2' - 1 0 " 2' - 8 " OPEN LT-1 LT-2PTPT PT 11.52 PT 26.52 RBRB TILE TILE 6.14 26.2711.56 LE D W A L L +/ - 8 ' - 8 " LED WALL +/- 7' - 11" BA S E 4" 26.2526.25 8.16 E7.10 E7.10 E7.10 E7.10 7.35 10.03 10.03 12.48 +/ - T O R O O F D E C K 4' - 0 " B.O. ROOF DECK 13' -0" 23.06 FINISH FLOOR 0' -0" CEILING 9' -0" T.O.P. 24' -0" BCD 3' - 0 " BO T T O M O F C E I L I N G 9' - 0 " ADJACENT TENANT N.I.C BO T T O M O F C E I L I N G 9' - 0 " KITCHEN 6 WALK-IN FRIDGE 8 RETAIL 9 TOILET 10OFFICE/STORAGE 12 BO T T O M O F L I G H T T A C K 9' - 6 " PT 26.52 PTTILEPT FRP 26.52 7.35 7.35 23.1123.11 26.25 8' - 0 " 23.04 RB +/ - T O R O O F D E C K 4' - 0 " B.O. ROOF DECK 13' -0" FINISH FLOOR 0' -0" 9' - 0 " 9' - 0 " KITCHEN 6 KITCHEN 6 SERVICE COUNTER 5 WAITING 3 BO T T O M O F L I G H T T R A C K 9' - 6 " 2' - 8 " 6.14 26.52 23.06 E70.10 7.35 TE M P G L A S S 5' - 6 " OP E N I N G 1' - 1 0 " 3' - 2 " 3' - 0 " 26.28 +/ - T O R O O F D E C K 4' - 0 " B.O. ROOF DECK 13' -0" 312 3' - 6 " FINISH FLOOR 0' -0" T.O.P. 24' -0" LOW CEILING 9' -0" 05 WALK-IN FRIDGE 8 SUSHI PREP. AREA 7 ENTRY LOBBY 1 3' - 6 " 26.27 PTPT E70.10 7.35 B.O. ROOF DECK 13' -0" 312 1' - 6 " 2' - 1 0 " 6.14 RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt BUILDING SECTIONS A301 1/4" = 1'-0"1SECTION 1 1/4" = 1'-0"2SECTION 2 1/4" = 1'-0"3SECTION 3 1/4" = 1'-0"4SECTION 4 GENERAL NOTES KEY NOTE # DESCRIPTION 6.14 SOLID SURFACE COUNTER TOP 7.35 EXISTING ROOF INSULATION AND ROOF SYSTEM. REPAIR AS REQUIRED. GC TO MAINTAIN THE INSULATION R VALUE PER ENERGY CODE REQUIREMENTS 8.16 FRAMELESS TEMPER GLASS SCREEN 10.03 TENANT SIGNAGE(PROVIDE POWER). GC TO PROVIDE BACKING FOR THE SIGN AS REQUIRED. 11.52 LED WALL PANEL. GC TO PROVIDE POWER AND WALL BACKING FOR THE LED PANEL. REFER TO ELEC DWG FOR MORE DETAIL INFORMATION. 11.56 RETAIL SHELVING, SEE EQUIPMENT PLAN 12.48 JAPANESE STYLE CURTAIN. PROVIDE BY OWNER, INSTALL BY GC. 23.04 EXHAUST FAN: PROVIDE CURBED ROOF OPENING. SEE MECH DWG AND STRUCTURAL DWG 23.06 KITCHEN EXHAUST HOOD, SEE MECHANICAL DRAWING 23.11 NEW MECHANICAL DUCTWORK, SEE MECH DWG" 26.25 LIGHTING FIXTURE, SEE ELEC. DWG 26.27 LED TAPE LIGHT FIXTURE BELOW COUNTERTOP, SEE ELEC DWG 26.28 LED TAPE LIGHT FIXTURE AT CASEWORK BASE, SEE ELEC DWG 26.52 EMERGENCY LIGHTING E7.10 (E) CLASS 'A' BUILT-UP ROOFING SYSTEM, PATCH IMPACTED AREA TO MATCH EXISTING E70.10 (E) MECH EQUIPMENT, REPAIR AS NEEDED. GC TO VERIFY IN FIELD FINISH SCHEDULE -REFER TO SHEET A101 BUILDING SECTION LEGEND NOTE: INSTALL AND RUN DUCTWORK WITHIN THE OPEN CEILING AREA, EITHER BETWEEN THE OPENINGS OF THE WEB JOISTS OR TIGHT TO THE BOTTOM OF THE TJI BEAMS. THE DUCTWORK IN OPEN CEILING AREAS SHALL BE LOCATED ABOVE THE LIGHTING FIXTURES. PAINT ALL EXPOSED DUCTWORK TO MATCH THE ROOF DECK COLOR. FINISH FLOOR 0' -0" B TO P O F B U I L T I N C O U N T E R H I G H 2' - 1 0 " 3' - 6 " LOW CEILING 9' -0" 6.15 9' - 6 " GL A S S 9' - 0 " EQ EQ RB RB PT 26.52 OPEN 6.14 8.16 60.03 26.25 10.0310.03 26.28 B.O. ROOF DECK 13' -0" FINISH FLOOR 0' -0" CEILING 9' -0" B C LOW CEILING 9' -0" BO T T O M O F C E I L I N G A T C H E C K O U T C O U N T E R 9' - 0 " 23.21 34 " M A X BO T T O M O F S O F F I T 9' - 0 " 6.14 26.25 B.O. ROOF DECK 13' -0" 23.1123.1123.11 FINISH FLOOR 0' -0" LOW CEILING 9' -0" OPEN TO BEYOND 6.15 2' - 1 0 " GL A S S 3' - 0 " 4' - 0 " RB PT 26.27 PT 2' - 6" 8.16 26.25 GREEN WALL 12.48 B.O. ROOF DECK 13' -0" FINISH FLOOR 0' -0" FINISH FLOOR 0' -0" LOW CEILING 9' -0" D6.13 34 " M A X 9' - 2 " A102 4 6.14 11.56 11.52 26.25 RB B.O. ROOF DECK 13' -0" 23.11 RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt INTERIOR ELEVATIONS A401 GENERAL NOTES KEY NOTE # DESCRIPTION 6.14 SOLID SURFACE COUNTER TOP 6.15 WOOD FINISH COUNTER TOP WITH FLOATING COUNTERTOP WALL BRACKET @ MAX. 4'-0" O.C. 8.16 FRAMELESS TEMPER GLASS SCREEN 10.03 TENANT SIGNAGE(PROVIDE POWER). GC TO PROVIDE BACKING FOR THE SIGN AS REQUIRED. 11.52 LED WALL PANEL. GC TO PROVIDE POWER AND WALL BACKING FOR THE LED PANEL. REFER TO ELEC DWG FOR MORE DETAIL INFORMATION. 11.56 RETAIL SHELVING, SEE EQUIPMENT PLAN 12.48 JAPANESE STYLE CURTAIN. PROVIDE BY OWNER, INSTALL BY GC. 23.11 NEW MECHANICAL DUCTWORK, SEE MECH DWG" 23.21 AIR CURTAIN, SEE EQUIPMENT PLAN 26.25 LIGHTING FIXTURE, SEE ELEC. DWG 26.27 LED TAPE LIGHT FIXTURE BELOW COUNTERTOP, SEE ELEC DWG 26.28 LED TAPE LIGHT FIXTURE AT CASEWORK BASE, SEE ELEC DWG 26.52 EMERGENCY LIGHTING 60.03 GYM. BD. SOFFIT WITH LED COVE LIGHT ABOVE, SEE ELEC. DWG D6.13 (E) CASEWORK TO BE REMOVED THROUGHOUT THE SPACE. 3/8" = 1'-0"1LOBBY-A 3/8" = 1'-0"3LOBBY-C 3/8" = 1'-0"4LOBBY-D 3/8" = 1'-0"2LOBBY-B FINISH SCHEDULE -REFER TO SHEET A101 INTERIOR ELEVATION LEGEND 1. GC TO PROVIDE ALL THE NECESSARY BACKING AS REQUIRED NOTE: INSTALL AND RUN DUCTWORK WITHIN THE OPEN CEILING AREA, EITHER BETWEEN THE OPENINGS OF THE WEB JOISTS OR TIGHT TO THE BOTTOM OF THE TJI BEAMS. THE DUCTWORK IN OPEN CEILING AREAS SHALL BE LOCATED ABOVE THE LIGHTING FIXTURES. PAINT ALL EXPOSED DUCTWORK TO MATCH THE ROOF DECK COLOR. FINISH FLOOR 0' -0" PT PTLT-1 RB B.O. ROOF DECK 13' -0" FINISH FLOOR 0' -0" CEILING 9' -0" C D23.21 PT PT RB LT-1LT-2 26.2526.25 9' - 0 " B.O. ROOF DECK 13' -0" FINISH FLOOR 0' -0" CEILING 9' -0" 9' - 0 " 9' - 0 " OPEN TO BEYOND PT PT RB RB 26.52 LT-1 M U L L I O N H I G H MA T C H ( E ) W I N D O W M U L L I O N H I G H MA T C H ( E ) W I N D O W 4' - 0" B.O. ROOF DECK 13' -0" 2 FINISH FLOOR 0' -0" CEILING 9' -0" 9' - 0 " OPEN TO BEYOND PT PT 34 " M A X 6.14 26.25 11.02 11.02 B.O. ROOF DECK 13' -0" 32 3/8" = 1'-0"1RETAIL-A 3/8" = 1'-0"2RETAIL-C RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt INTERIOR ELEVATIONS A402 GENERAL NOTES KEY NOTE # DESCRIPTION 6.14 SOLID SURFACE COUNTER TOP 11.02 COLD DISPLAY CASE. SEE FS101-EQUIPMENT SHEET AND ELEC DWG. FOR MORE INFO. 23.21 AIR CURTAIN, SEE EQUIPMENT PLAN 26.25 LIGHTING FIXTURE, SEE ELEC. DWG 26.52 EMERGENCY LIGHTING 3/8" = 1'-0"3RETAIL-B 3/8" = 1'-0"4RETAIL-D OPEN FINISH SCHEDULE -REFER TO SHEET A101 INTERIOR ELEVATION LEGEND 1. GC TO PROVIDE ALL THE NECESSARY BACKING AS REQUIRED FINISH FLOOR 0' -0" CEILING 9' -0" SST TILE 26.52 3' - 0 " 7' - 6 " 3' - 2 " GRAM BAR 4 KITCHEN 6 KITCHEN 6 4' - 0 " GL A S S 3' - 0 " 3 12 FINISH FLOOR 0' -0" CEILING 9' -0" SST RB 26.52 PT 4' - 0 " FINISH FLOOR 0' -0" CEILING 9' -0" 36 " H I G H C O U N T E R 34 " M A X GL A S S ADJUSTABLE UNDER COUNTER SHELVES 4" OPEN TO BEYOND FINISH FLOOR 0' -0" C LOW CEILING 9' -0" OPEN TO BEYOND QT QT 11.02 12.48 QT FINISH FLOOR 0' -0" C LOW CEILING 9' -0" QT QT 5' - 0 " 3' - 1 1 1 / 2 " TILE FINISH FLOOR 0' -0" CEILING 9' -0" OPEN 3' - 2 " 1' - 1 0 " TILE 26.52 ADJUSTABLE UNDER COUNTER SHELVES 5' - 11 1/2" FINISH FLOOR 0' -0" CEILING 9' -0" LOW CEILING 9' -0" QT 11.02 2 FINISH FLOOR 0' -0" CEILING 9' -0" OPEN TO BEYOND QT 2 FINISH FLOOR 0' -0" CEILING 9' -0" C PT PT OPEN TO BEYOND OPEN TO BEYOND 7' - 11"8' - 8 " LED WALL PANEL SCREEN RB 12.48 RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt INTERIOR ELEVATIONS A403 GENERAL NOTES KEY NOTE # DESCRIPTION 11.02 COLD DISPLAY CASE. SEE FS101-EQUIPMENT SHEET AND ELEC DWG. FOR MORE INFO. 12.48 JAPANESE STYLE CURTAIN. PROVIDE BY OWNER, INSTALL BY GC. 26.52 EMERGENCY LIGHTING 3/8" = 1'-0"7GRAM BAR-A 3/8" = 1'-0"8GRAM BAR-B 3/8" = 1'-0"6SERVICE COUNTER-A 3/8" = 1'-0"3SUSHI BAR-C 3/8" = 1'-0"1SUSHI BAR-A 3/8" = 1'-0"5SERVICE COUNTER-B 3/8" = 1'-0"2SUSHI BAR-B 3/8" = 1'-0"4SUSHI BAR-D 3/8" = 1'-0"9SUSHI BAR-E FINISH SCHEDULE -REFER TO SHEET A101 INTERIOR ELEVATION LEGEND 1. GC TO PROVIDE ALL THE NECESSARY BACKING AS REQUIRED FINISH FLOOR 0' -0" CEILING 9' -0" B 26.52 FRP RB PT FINISH FLOOR 0' -0" CEILING 9' -0" B 8' - 0 " F R P 4" FRP RB PT OPEN TO BEYOND FINISH FLOOR 0' -0" CEILING 9' -0" B OPEN 26.52 SST RB OPEN TO BEYOND 3' - 2 " 1' - 1 0 " FINISH FLOOR 0' -0" CEILING 9' -0" B 26.52 FRP RB PT SST FINISH FLOOR 0' -0" CEILING 9' -0" 23.21 FRP RB FINISH FLOOR 0' -0" CEILING 9' -0" RB PT 26.52 OPEN TO BEYOND KITCHEN 6 12 3/8" = 1'-0"5KITCHEN-E 3/8" = 1'-0"4KITCHEN-D 3/8" = 1'-0"1KITCHEN-A RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt INTERIOR ELEVATIONS A404 GENERAL NOTES KEY NOTE # DESCRIPTION 23.21 AIR CURTAIN, SEE EQUIPMENT PLAN 26.52 EMERGENCY LIGHTING 3/8" = 1'-0"2KITCHEN-B 3/8" = 1'-0"3KITCHEN-C 3/8" = 1'-0"6KITCHEN-F FINISH SCHEDULE -REFER TO SHEET A101 INTERIOR ELEVATION LEGEND 1. GC TO PROVIDE ALL THE NECESSARY BACKING AS REQUIRED FINISH FLOOR 0' -0" T.O.P. 24' -0" V. I . F . 4' - 6 " ABCD JAPANMART PROJECT AREA 10.52 8.05 8.05E8.05 AND DOOR NEW STOREFRONT AND DOOR NEW STOREFRONT NEW STOREFRONT 10.52 10.52 NOTE: STOREFRONT SIGN UNDER SEPARATED PERMIT AND SUBMITTAL B.O. ROOF DECK 13' -0" FINISH FLOOR 0' -0" T.O.P. 24' -0" A B C D PROJECT AREA E8.05 B.O. ROOF DECK 13' -0" FINISH FLOOR 0' -0" T.O.P. 24' -0" PROJECT AREA 8.05 NE W D O O R 7' - 0 " B.O. ROOF DECK 13' -0" RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt EXTERIOR ELEVATIONS A405 GENERAL NOTES KEY NOTE1/8" = 1'-0"1EAST ELEVATION 1/8" = 1'-0"2WEST ELEVATION (PARTIAL) 1/8" = 1'-0"3NORTH ELEVATION # DESCRIPTION 8.05 DOOR 10.52 PROPOSED AREA FOR EXTERIOR SIGNAGE. PROVIDE POWER FOR ILLUMINATED SIGN. SEE ELEC DWG. E8.05 (E) DOOR 1. GC TO PROVIDE ALL THE NECESSARY BACKING AS REQUIRED FLOOR TILE ON THINSET SLOPE SLAB AND C.T. 1/4" PER FOOT NEW FLOOR DRAIN CONCRETE SLAB AND GROUT SOLID TO PROVIDE G.C. SHALL BUSH HAMMER EXIST. SLAB REQUIRED SLOPE SLOPE 1:50SLOPE 1:50 WATERPROOF MEMBRANE NOTE: FLOOR DRAIN REFER TO AND PLUMBING DRAWING FOR MORE INFORMATION EXTEND FROM WALL TO WALL AND WRAP MEMBRANE UP COVE BASE AND SEAL FOR WATERTIGHT INSTALLATION STEEL ANGLE SUPPORT. REFER TO 4 HR RATED FIREPROOING STRUCTURAL FOR MORE INFORMATION 2'-0" 2'-0" FINISH FLOOR WALL FINISH. REFER TO FINISH SCHEDULE EPOXY FINISH FLOOR 3/4" RADIUS COVE 1/8" GROUT TOP AS REQUIRED 4" 5/8" GYP BD (E) FLOOR SLAB WALL TILE. REFER TO FINISH SCHEDULE 5/8" GYP BD 4" HIGH 3/8" RADIUS TILE COVE BASE TILE FINISH REFER TO FINISH SCHEDULE GROUT (E) FLOOR SLAB WALL TILE. REFER TO FINISH SCHEDULE TILE EDGE TRIM EPOXY FINISH FLOOR COVE STRIP 3/4" RADIUS COVE 1/8" 5/8" GYP BD EPOXY FINISH FLOOR 3/4" RADIUS COVE WHITE FRP EDGE TRIM "MARLITE FRP" SEE FINISH PLAN FOR MORE DETAILS (E) DECK ABOVE PAINTED 5/8" GYP BD 1/8" 4" COVE STRIP FINISH FLOOR STAINLESS STEEL TRIM STAINLESS STEEL PANEL.REFER TO FINISH SCHEDULE (E) DECK ABOVE 5/8" GYP BD EPOXY FINISH FLOOR 3/4" RADIUS COVE 1/8" COVE STRIP 4" RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt INTERIOR DETAILS A406 3" = 1'-0"1EPOXY BASE 3" = 1'-0"2TILE BASE 3" = 1'-0"3 EPOXY BASE AT CONC FLOOR 3" = 1'-0"4EPOXY BASE WITH FRP 3" = 1'-0"5 EPOXY BASE WITH SS PANEL 1 1/2" = 1'-0"6FLOOR DRAIN 3" 5 1 / 2 " TO F . F . @ B A S E 1 6 " O .C . 1 6 " O .C . 1 6 " O .C . 1 6 " O .C . 2 -3 5/8" 16 GA. STEEL STUD STAGGERED BACK TO BACK FOR LOADS OVER 50 LBS. PER STUD 3 5/8" 16 GA. STEEL STUD 6" X 1-1/4" X 16 GA. UNPUNCHED STEEL TRACK WELD 3-#10 SCREWS @ EACH STUD. NOTE: ALL BACKING PLATES SHALL BE CONTINUOUS OVER A MINIMUM OF 3 STUDS. PATCH AND REPAIR EXISTING GYP BOARD OR LEAD LINED GYP BOARD AS REQUIRED OVER 50 LB B UNDER 50 LB A 6" X 1-1/4" X 16 GA. UNPUNCHED STEEL TRACK ATTACHED TO EACH STUD. FILLER STRIPS FLUSH WITH BACKING PLATE (TYP.) FILLER STRIPS FLUSH WITH BACKING PLATE (TYP.) CABINET PROVIDE #12x3~8" LOW PROFILE HEAD SCREWS @ 12"o.c. TYPICAL TOP & BOTTOM BACKING AT CABINET 6" X 1-1/4" X 16 GA. UNPUNCHED STEEL TRACK 10 A510 TYP10 A510 TYP 4 A510 SIM.4 A510 SIM. 4 A510 SIM. 7 A510 SIM. 9 A510 TYP 9 A510 TYP 4 A510 SIM. 1 A510 SIM. 6 A510 SIM. 7 A510 SIM. OPTION TO WELDS SHOWN 2 -# 10 SCREWS @ 12" O/C TO EACH LINTEL MEMBER 16 GA. UNPUNCHED TRACK TOP AND BOTTOM OF LINTEL STUD WIDTH LINTEL PER SCHEDULE DOUBLE JAMB (16GA) DO NOT DISCONTINUE AT LINTEL 7/8" MIN. BETWEEN SCREWS and END OF LINTEL WEB ATTACH TRACK TO DOUBLE JAMB SIMILAR TO BLOCKING CONNECTION TO STUD SCREWS EACH SIDE OF LINTEL TO JAMB PER SCHEDULE AA 10 SCREWS (20 TOTAL)(2) 1000 S200-68 (2) 800 S200-68 (2) 600 S200-54 10'-0" 8'-0" 6'-0" 4'-0" MAX. LENGTH HDR 6 SCREWS (12 TOTAL) 4 SCREWS (8 TOTAL) #10 SCREWS EACH SIDE OF BEAM TO JAMB 8 SCREWS (16 TOTAL) BEAM SIZE (2) 400 S200-54 MARK HDR HDR HEADER/ SCHEDULE HDR CONNECTION TO JAMB AA -LINTEL SECTION 1/8 1-12 B 4' -0" O C MA X , T Y P MA X . 4' -0" BRACING SPLICE FLANGE BRACING 3 SCREWS EACH END GYPSUM BOARD WHERE OCCURS STUD TRACK BLOCKING (@ SPLICE ONLY) MIN. 3 SHEET METAL SCREWS PER BLOCK @ JOISTED CEILINGS ONLY PARTITION STUDS TRACK BLOCKING (@ SPLICE ONLY) BEND ENDS UP & SCREW TO STUD (1) SCREW PER STUD FLANGE BRACING DETAIL B SECTION -BRACING SPLICE DETAIL C PLAN -BRACING SPLICE C USE STUD WALL FLANGE BRACING 4'-0" O.C. ON SIDE(S) OF PARTITION WHERE GYPSUM BOARD SHEATHING DOES NOT OCCUR, INCLUDING ABOVE THE CEILING. FLANGE BRACING: 20 GA. 1 1/2" WIDE METAL STRAP OR 1 1/2" COLD-ROLLED CHANNEL TRACK BLOCKING (@ SPLICE ONLY) FLOOR SLAB WALL MATERIAL UNDERSIDE OF STRUCTURE DETAIL A - SECTION NOTE: HORIZONTAL BRACING SHALL BE PROVIDED WHERE GYPSUM BOARD IS ABSENT ON ONE OR BOTH SIDES OF WALL OR IT DOES NOT EXTEND TO THE STRUCTURE ABOVE. THIS IS TO PROVIDE RESISTANCE TO BENDING AND ROTATION ABOUT THE MINOR AXIS. PROVIDE BLOCKING @ 8'-0" O.C AT STUD SPACE AND MAXIMUM 2'-0" O.C VERTICAL SPACING WHERE GYPSUM BOARD OCCURS ON SINGLE FACE, EXTEND STRAPS AND BLOCKING FULL HEIGHT @ 2'-0" O.C MAXIMUM. BRACE SHALL BE LOCATED AT THE POINT OF TERMINATION OF GYPSUM BOARD AND JUST BELOW THE SLIP JOINT AT TOP. IF GYPSUM BOARD IS PRESENT ON ONE SIDE, THE STRAP BRACING MAY BE OMITTED ON THAT SIDE. BLOCKING AT EACH RUN TERMINATION REQUIRED UNLESS WELDED; BOXED KING STUD OCCURS AT TERMINATION OF STRAPPING. NOTE : REFER TO WALL TYP FF FURRING WALL ON DETAIL 2/A511 TYP. 2"x2" ANGLE, SAME GAGE AS METAL STUD METAL STUD STANDARD WEB PUNCHOUT CRC MAY BE PLACED EITHER FLANGE UP OR FLANGE DOWN. 1~8"x16 GA CRC -COLD ROLLED CHANNEL @ 4'-0"o.c. HORIZONTALLY 2"x2" ANGLE, SAME GAGE AS METAL STUD WITH 4#10 -~8" PAN HEAD SCREWS TYPICAL SCREWED STUD BRIDGING NOTE: FOR METAL STUD TYPE AND SPACING PER WALL TYPE. 1~8"x16 GA CRC -COLD ROLLED CHANNEL @ 4'-0"o.c. HORIZONTALLY METAL STUD STANDARD WEB PUNCHOUT STUD BRIDGING TYPICAL WELDED ~8" FOR METAL STUD TYPE AND SPACING SEE WALL TYPE. 1-12 EACH SIDE WHERE TRACKS DO NOT OCCUR PROVIDE 16 GAUGE TRACK EACH SIDE OF JAMB WHERE LINTEL SPAN IS > 6'-0" AT LOAD BEARING WALLS 1-121/8 EACH SIDE WHERE TRACKS OCCUR ALL INTERIOR WALLS: 2-600S200-54 (33KSI) 1/2" MIN. 1/ 2 " EQ . EQ .VA R I E S VARIES 6" MA X . D EQ EQ 3/ 4 " M I N . WIDTH STUD MINUS 3/16" JAMB DEPTH 3/ 4 " M I N . 3/ 4 " M I N . WIDTH STUD F R A M E F A C E M I N U S 3 /1 6 M I N U S 3 /1 6 F R A M E F A C E12"M I N . 5 /8 "M A X . NOTE 1: OMIT BRACE WHEN "D" DIMENSION IS LESS THAN 2'-0" FOR GYP. WALLBD. OR 16" FOR PLASTER PARTITION. SECTION B VERTICAL STUDS @ 2'-0" MAX. W/GYPSUM WALLBD. 1'-4" W/GYPSUM LATH & PLASTER DOUBLE STUDS FOR SUPPORTING CONC. BACKER BOARD. PROVIDE CONTINUOUS BRACING WHEN STUDS EXCEED 10'-0" [3048mm] & ARE FINISHED BOTH SIDES JAMB ANCHOR CLIPS 3 PER SIDE - COORDINATE W/HINGE REINFORCEMENT. DETAIL D SEE NOTE 1 RUNNER BET. STUDS SEE DOOR SCHEDULE SHIM AS REQ'D. SEC. B GYPSUM WALLBD. PANELS CONTROL JOINT ISOMETRIC OF CONSTR. JT. ELEVATION AT DOOR FRAME DETAIL D PROVIDE SOUND DEADENING WHERE REQ'D. SANITARY STOP METAL DOOR FRAME METAL ANCHOR CLIP SHIM AS REQ'D. DETAIL C JAMB ANCHOR SECTION A DOUBLE STUDS DETAIL C JAMB ANCHORS (FURNISHED WITH FRAME) MET. DOOR FRAME 1/2" CONST JOINT [13mm] CRIPPLE STUD DO NOT ANCHOR TO BEARING STUD A A DUCT OPENING DETAIL C SLOTTED TOP TRACK SLOTTED CLG TRACK, 16 GAUGE, SEE DETAIL B #8 SCREW CENTER OF SLOT PER PRE-APPROVAL 16 GA. RUNNER TRACK FASTEN TO STRUCTURE W/ 1.77" DIA. X 1 1/4" SHOTPINS SPACED AT 24" O.C. MAX. T.O. STUD 09110 16 GA TOP TRACK1/4" TYP. 1" TYP. 1 1 / 2 " TY P . 0' - 1 " PARALLEL TO FLUTES USE METAL-LITE, INC "SLOTTED TRACK SYSTEM", OR SLIPT RACK SYSTEMS, INC "SLP-TRK" DO NOT ATTACH TO BOTTOM CORD OF TRUSS DETAIL B RER TO DETAIL 10/A515 16 GA. RUNNER TRACK FASTEN TO STRUCTURE W/ .177" DIA. X 1 1/4" SHOTPINS SPACED AT 24" O.C. MAX. FASTEN STUD TO TRACK WITH (1) # 8 SMS TYP. FLOORING 2"X2"X12" LONG 16GA. STL. ANGLE SPAN 2 FLUTES 4"X18GA. DIAGONAL BRACE (2) #10 X 1" SMS EACH BRACE ANCHOR TO DECK W/ (2) # 12 SMS (SHOT-IN ANCHORS AT CONCRETE DECK) CONT. RUNNER TRACK CEILING WHERE OCCURS SEE PLAN FOR WALL TYPE 45.00° 6" 1 1/2" = 1'-0"8 TYPICAL PARTITION BRACING RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt INTERIOR PARTITION FRAMING DETAILS A510 3" = 1'-0"1BACKING DETAIL 3" = 1'-0"3 TYPICAL NON-LOAD BEARING PARTITION WALL 3" = 1'-0"4 LINTEL/CONNECTION TO JAMB 3" = 1'-0"5WALL BRACING DETAIL 3" = 1'-0"11METAL STUD BRIDGING 3" = 1'-0"7TYP. STUD JAMB SECTION 1 1/2" = 1'-0"6 PARTITION FRAMING FOR DOOR DETAIL 3" = 1'-0"10 WALL ANCHORAGE TO STRUCTURE 3" = 1'-0"9 WALL ANCHORAGE TO FLOOR 20'-1" TO 25' 1 5/8" X 6" X 18GA. (4) #10 EACH END 16'-1" TO 20' 1 3/8" X 6" X 18GA. (4) #10 EACH END 12'-1" TO 16' 1 3/8" X 4" X 20GA. (3) #10 EACH END 6'-1" TO 12' 1 1/4" X 3 5/8" X 20GA. (3) #10 EACH END 6' OR UNDER 1 1/4" X 3 5/8" X 20GA. (3) #10 EACH END BRACING LENGTH SIZE SCREWS 30'-1" TO 45'-0" 2 1/2" X 8" X 14 GA. @ 16" O.C. 26'-1" TO 30'-0" 1 1/4" X 6" X 16 GA. @ 16" O.C. 20'-1" TO 26'-0" 1 1/4" X 6" X 18 GA. @ 16" O.C. 18'-1" TO 20'-0" 1 1/4" X 3 5/8" X 20 GA. @ 16" O.C. 15'-1" TO 18'-0" 1 1/4" X 3 5/8" X 20 GA. @ 16" O.C. 0' TO 15'-0" 1 1/4" X 3 5/8" X 20 GA. @ 16" O.C. HEIGHT BETWEEN SUPPORTS ICC-ESR-3064P INTERIOR METAL STUD SIZE & SPACING REMARK INTERIOR METAL STUD SCHEDULE NOTE: REFER TO STRUCTURAL DRAWING FOR MORE DETAIL INFORMATION NOTE: REFER TO STRUCTURAL DRAWING FOR MORE DETAIL INFORMATION SE E M A N U F A C T U R E F O R R O U G H O P E N I N G 48 " M A X . A . F . F . T O ℄ OF H A N D L E PLAN SECTION AT 1 HR. CONDITIONS WRAP 5/8" TYPE "X" GYP. BD. INTO CAVITY BEHIND CABINET AND FIRE TAPE METAL SEMI-RECESSED FIRE EXTINGUISHER CABINET ACOUSTIC INSUL WHERE OCCURS SEMI-RECESSED FIRE EXTINGUISHER CABINET SEE MANUFACTURER FOR ROUGH OPENING 5/8" GYP. BD. BEHIND CABINET RATED PARTITION AS SCHEDULED ONLY IN PUBLIC AREA ELEVATION SECTION DUCT PENETRATION ELEVATION SECTION BEAM PENETRATION SECTIONELEVATION PENETRATIONS OF ACOUSTICAL PARTITIONS BY DUCT, CONDUIT, CABLE, PIPES ETC. SHALL BE ACOUSTICALLY SEALED AS SHOWN. ANY GAP LARGER THAN 1/2" SHALL BE COVERED WITH GYPSUM BOARD, LAPPED A MINIMUM OF 2" AND SCREWED BEFORE USING ACOUSTICAL SEALANT. CLOSED CELL POLYURETHANE FOAM OR FIRE RATED SILICONE FOAM 1/2" CLEAR (TYP.) DUCT OR SOUND TRAP FIBERGLASS INSULATION 1.5 PCF MAX. 100% FILL FIBERGLASS INSULATION 1 . 5 PCF MAX. 100% FILL STRUCT DECK ACOUSTICAL SEALANT STEEL BEAM ACOUSTICAL SEALANT WALL TYPE VARIES PER PLAN LH4 SEE PLAN 4" STUDS STRUCTURE ABOVE CEILING WHERE OCCURS LOW WALL SEE STRUCTURAL DRAWING FOR MORE INFORMATION WALL FINISH PER FINISH SCHEDULE WALL ANCHORAGE SEE STRUCTURAL DRAWING FF4 WALL FRAMING SEE A510 WALL FINISH PER FINISH SCHEDULE CONTINUOUS SEALANT BOTH SIDES (FINISH FLUSH W/ PARTITION) 3 5/8" STUDS STRUCTURE ABOVE 1 LAYER 5/8" GYP. BD. WATER RESISTANT GYP BD. AT RESTROOM AND WALL TILE FINISHES) PROVIDE METAL STUD BRACING 11/A511 @4' O.C A515 10 TYP A510 9 TYP +/-13'-0" FH4 3 5/8" STUDS STRUCTURE ABOVE CEILING AS OCCURS METAL STUD, SEE SCHEDULE PER SHEET A510 FOR SIZE 1 LAYER 5/8" TYPE X GYP BD WALL FINISH PER FINISH SCHEDULE CONT SEAL TYP EACH SIDE FINISH FLUSH W/GYP BD AB O V E C E I L I N G 6 " OPEN CEILING FH4A 3 5/8" STUDS WITH ACOUSTICAL INSULATION A515 10 TYP SE E C E I L I N G P L A N A510 9 TYP 5/8" TYPE X GYP BD (WATER RESISTANT GYP BD. AT RESTROOM AND WALL TILE FINISHES) +/-13'-0" PH4 3 5/8" STUDS STRUCTURE ABOVE CEILING AS OCCURS METAL STUD, SEE SCHEDULE PER SHEET A510 FOR SIZE 1 LAYER 5/8" TYPE X GYP BD EACH SIDE WALL FINISH PER FINISH SCHEDULE CONT SEAL TYP EACH SIDE FINISH FLUSH W/GYP BD AB O V E C E I L I N G 6 " PH4A 3 5/8" STUDS WITH ACOUSTICAL INSULATION A515 10 TYP SE E C E I L I N G P L A N A510 9 TYP +/-13'-0" PARTITION TYPE GENERAL NOTES THE "PARTITION TYPE TAG", ILLUSTRADED BELOW, REPRESENTS THE COMPLETE EXTENT OF ALL PARTITIONS INDICATED BY THE SYMBOL ON THE FLOOR PLANS, AND OTHER DRAWINGS IN THE PROJECT DOCUMENTS. REFER TO PARTITION TYPE DETAILS INDICATED BY THE "PARTITION TYPE" CHARACTER ON THE TAG, FOR EXAMPLE: DETAIL "TYPE A". REFER TO THE FIRE RATING LEGEND FOR THE FIRE RESISTANCE CLASSIFICATION NOTED BY THE "FIRE RATING INDICATION" ON THE TAG, FOR EXAMPLE: "1"=60 MIN FIRE-RESISTANCE RATED ASSEMBLY. REFER TO METAL STUD SIZE OR CMU NOM WIDTH AS INDICATED BY THE "METAL STUD/CMU WIDTH" CHARACTER ON THE TAG, AS SHOWN ON PARTITION TYPE DETAILS, FOR EXAMPLE "3"=3-5/8" METAL STUDS. REFER TO THE "PARTITION TYPE MODIFIER" NOTES BELOW, WHICH APPLY TO EACH PARTITION WHERE MODIFIER CHARACTER(S) ARE SHOWN ON THE TAG. REFER TO THE "PARTITION KEYNOTES" AS INDICATED, WHICH APPLY TO EACH PARTITION WHERE KEYNOTE CHARACTER(S) ARE SHOWN ON THE TAG. REFER TO SHEET A510 FOR TYPICAL FRAMING DETAILS. GENERAL NOTES-SEISMIC ZONES IBC D-F, CBC3-4: ALL METAL STUD PARTITION TYPES SHALL COMPLY WITH PARTITION TYPE GENERAL NOTES, AND ALL METAL STUDS SHALL BE MIN 20 GA, UNO. ALL CMU PARTITION TYPES SHALL COMPLY WITH PARTITION TYPE GENERAL NOTES, AND REINFORCING AS INDICATED ON THE STRUCTURAL DRAWINGS, UNO. WALL TYPE NOTES: 1.TYPE "X" GYP WALL BOARD SPECIFIED THROUGHOUT UNLESS OTHERWISE SPECIFIED. PROVIDE MOISTER RESISTANT GYP BOARD AT ALL WET WALLS. PROVIDE TILE BACKER BOARD ON ALL WALLS WITH TILE. FIRE RESISTANT ASSEMBLIES TILE BACKER BOARD SHALL BE PROVIDED OVER THE FIRE RESISTANT SYSTEM. 2.INSTALL CONTROL JOINTS MAXIMUM 30'-0" O.C. INTERVAL WHERE A CONTROL JOINT OCCURS IN AN ACOUSTICAL OR FIRE RATED SYSTEM, BLOCKING SHALL BE PROVIDED BEHIND THE CONTROL JOINT BY USING A BACKING MATERIAL SUCH AS 5/8" TYPE "X" GYP BOARD, MINERAL FILLER OR OTHER TESTED EQUIVALENT. 3.CONFORM TO DETAILED REQUIREMENTS OF DESIGNATED TESTING AUTHORITY NUMBERS AT ALL WALLS. WALLS DESIGNATED AS "BASED ON" VARY AS NOTED IN PARENTHESIS. SEE STRUCTURAL SHEAR WALLS SCHEDULE FOR SHEAR WALL ATTACHMENT AND EDGE BLOCKING REQUIREMENTS WHERE APPLICABLE. STRUCTURAL SHEAR WALL SCHEDULE OVERRIDES LISTED ASSEMBLY ATTACHMENT AND BLOCKING REQUIREMENTS ONLY WHEN MORE RESTRICTIVE. 4.WALL TYPES STATED AS "BASED ON" A LISTED ASSEMBLY MIGHT VARY IN STUD SIZE. NO EXACT LISTED ASSEMBLY EXISTS. PER GA-600-2012 P.9 ITEM 16, "GREATER STUD SIZES (DEPTH) SHALL BE PERMITTED TO BE USED IN METAL -OR WOOD -STUD SYSTEMS." THESE WALLS CAN ALSO BE SHOWN TO MEET THE REQUIRED FIRE RESISTIVE RATING BY THE CALCULATION METHOD PER SECTION 703.3.3 AND SECTION 721 IF REQUIRED. 5.WALL TYPES STATED AS "BASED ON" A LISTED ASSEMBLY MIGHT VARY DUE TO ADDITION OF EXTRA LAYER(S) OF ELEMENTS. NO EXACT LISTED ASSEMBLY EXISTS. PER GA-600-2012 P. ITEM 22, "ADDITIONAL LAYERS OF TYPE "x" OR REGULAR GYP BOARD SHALL BE PERMITTED TO BE ADDED TO ANY SYSTEM." FASTENERS SPECIFIED FOR THE ATTACHMENT OF GYP BOARD APPLIED OVER THE ADDITIONAL LAYER(S) OF ELEMENTS SHALL BE INCREASED BY NOT LESS THAN THE THICKNESS OF THE ADDITIONAL LAYER(S). 6.METALLIC OUTLET BOXES SHALL BE PERMITTED TO BE INSTALLED IN WOOD AND STEEL STUD WALLS OR PARTITIONS HAVING GYPSUM BOARD FACINGS AND CLASSIFIED AS TWO HOURS OR LESS. THE SURFACE AREA OF INDIVIDUAL BOXES SHALL NOT EXCEED 16 SQUARE INCHES. THE AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE FEET. BOXES LOCATED ON OPPOSITE SIDES OF WALLS OR PARTITIONS SHALL BE IN SEPARATE STUD CAVITIES AND SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. APPROVED NONMETALLIC BOXES SHALL BE PERMITTED AS ALLOWED BY LOCAL CODE. PW4 3 5/8" STUDS STRUCTURE ABOVE CEILING AS OCCURS 2 1/2" CT STUD AT 24" OC. 1 LAYER 5/8" TYPE X GYP BD WALL FINISH PER FINISH SCHEDULE CONT SEAL TYP EACH SIDE FINISH FLUSH W/GYP BD AB O V E C E I L I N G 6 " STOREFRONT PW4A 2 1/2 STUDS WITH ACOUSTICAL INSULATION A515 10 TYP SE E C E I L I N G P L A N 1" LAYER 5/8" TYPE X GYP BD PAINT BLACK (MATTE) A510 9 TYP +/-13'-0" SECTION A-A 1. WALL ASSEMBLY -THE 1 OR 2 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300, U400 OR V400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS -WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 IN. BY 4 IN. (25 MM BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* -NOM 5/8 IN. (16 MM) THICK, 4 FT (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 14-1/2 IN (368 MM) FOR WOOD STUD WALLS AND 18 IN. (457 MM) FOR STEEL STUD WALLS. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS 1 HR WHEN INSTALLED IN A 1 HR FIRE RATED WALL AND 2 HR WHEN INSTALLED IN A 2 HR FIRE RATED WALL. 2. THROUGH PENETRANTS -ONE METALLIC PIPE OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM. PIPE OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR TUBING MAY BE USED: A. STEEL PIPE -NOM 12 IN. (305 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. COPPER TUBING -NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. C. COPPER PIPE -NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. 3. PIPE COVERING* -NOM 1 IN. OR 2 IN. (25 MM OR 51 MM) THICK HOLLOW CYLINDRICAL HEAVY DENSITY GLASS FIBER UNITS JACKETED ON THE OUTSIDE WITH AN ALL SERVICE JACKET. LONGITUDINAL JOINTS SEALED WITH METAL FASTENERS OR FACTORY-APPLIED SELF-SEALING LAP TAPE. TRANSVERSE JOINTS SEALED WITH METAL FASTENERS OR WITH BUTT STRIP TAPE SUPPLIED WITH THE PRODUCT. WHEN NOM 1 IN. (25 MM) THICK PIPE COVERING IS USED, THE ANNULAR SPACE BETWEEN THE PIPE COVERING AND THE CIRCULAR CUTOUT IN THE GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL SHALL BE MIN 1/4 IN. TO MAX 3/8 IN. (6 MM TO MAX 10 MM). WHEN NOM 2 IN. (51 MM) THICK PIPE COVERING IS USED, THE ANNULAR SPACE BETWEEN THE PIPE COVERING AND THE CIRCULAR CUTOUT IN THE GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL SHALL BE MIN 1/2 IN. TO MAX 3/4 IN. (13 MM TO MAX 19 MM). SEE PIPE AND EQUIPMENT COVERING -MATERIALS (BRGU) CATEGORY IN BUILDING MATERIALS DIRECTORY FOR NAMES OF MANUFACTURERS. ANY PIPE COVERING MATERIAL MEETING THE ABOVE SPECIFICATIONS AND BEARING THE UL CLASSIFICATION MARKING WITH A FLAME SPREAD INDEX OF 25 OR LESS AND A SMOKE DEVELOPED INDEX OF 50 OR LESS MAY BE USED. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS 3/4 HR WHEN NOM 1 IN. (25 MM) THICK PIPE COVERING IS USED. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS 1 HR AND 1-1/2 HR WHEN NOM 2 IN. (51 MM) THICK PIPE COVERING IS USED WITH 1 HR AND 2 HR FIRE RATED WALLS, RESPECTIVELY. 4. FIRESTOP SYSTEM -INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE DETAILS OF THE FIRESTOP SYSTEM SHALL BE AS FOLLOWS: A. FILL,VOID OR CAVITY MATERIALS* -WRAP STRIP -NOM 1/4 IN. (6 MM) THICK INTUMESCENT ELASTOMERIC MATERIAL FACED ON ONE SIDE WITH ALUMINUM FOIL, SUPPLIED IN 2 IN. (51 MM) WIDE STRIPS. NOM 2 IN. (51 MM) WIDE STRIP TIGHTLY WRAPPED AROUND PIPE COVERING (FOIL SIDE OUT) WITH SEAM BUTTED. WRAP STRIP LAYER SECURELY BOUND WITH STEEL WIRE OR ALUMINUM FOIL TAPE AND SLID INTO ANNULAR SPACE APPROX 1-1/4 IN.(32 MM) SUCH THAT APPROX 3/4 IN. (19 MM) OF THE WRAP STRIP WIDTH PROTRUDES FROM THE WALL SURFACE. ONE LAYER OF WRAP STRIP IS REQUIRED WHEN NOM 1 IN. (25 MM) THICK PIPE COVERING IS USED. TWO LAYERS OF WRAP STRIP ARE REQUIRED WHEN NOM 2 IN. (51 MM) THICK PIPE COVERING IS USED. 3M COMPANY -FS-195+ B. FILL,VOID OR CAVITY MATERIALS* -CAULK OR SEALANT -MIN 1/4 IN. (6 MM) DIAM CONTINUOUS BEAD APPLIED TO THE WRAP STRIP/WALL INTERFACE AND TO THE EXPOSED EDGE OF THE WRAP STRIP LAYER APPROX 3/4 IN. (19 MM) FROM THE WALL SURFACE. 3M COMPANY -CP 25WB+, IC 15WB+, FIREDAM 150+ CAULK OR FB-3000 WT SEALANT *BEARING THE UL CLASSIFICATION MARKING SYSTEM NO.W-L-5001 MAY 19, 2005 F RATINGS -1 AND 2 HR (SEE ITEM 1), T RATINGS -3/4, 1 AND 1-1/2 HR (SEE ITEM 3) L RATING AT AMBIENT -2 CFM/SQ FT, L RATING AT 400 F -LESS THAN 1 CFM/SQ FT 4B 3 A 2 4A 2 3 A 4A 4B 1B1A MAX PIPE OR CONDUIT DIAM IN. (MM)F RATING HR T RATING HR 1 (25)1 OR 2 0+, 1 OR 2 1 (25)3 OR 4 3 OR 4 4 (102)1 OR 2 0 6 (152)3 OR 4 0 12 (305)1 OR 2 0 SYSTEM NO.W-L-1001 JUNE 15, 2005 F RATINGS -1, 2, 3 AND 4 HR (SEE ITEMS 2 AND 3), T RATINGS -0, 1, 2, 3, AND 4 HR (SEE ITEM 3) L RATING AT AMBIENT -LESS THAN 1 CFM/SQ FT, L RATING AT 400 F -LESS THAN 1 CFM/SQ FT 1. WALL ASSEMBLY -THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS -WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* -NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM). 2.THROUGH PENETRANT -ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. STEEL PIPE -NOM 24 IN. (610 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE. B. IRON PIPE -NOM 24 IN. (610 MM) DIAM (OR SMALLER) SERVICE WEIGHT (OR HEAVIER) CAST IRON SOIL PIPE, NOM 12 IN. (305 MM) DIAM (OR SMALLER) OR CLASS 50 (OR HEAVIER) DUCTILE IRON PRESSURE PIPE. C. CONDUIT -NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING D. COPPER TUBING -NOM 6 IN. (152 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING E. COPPER PIPE -NOM 6 IN. (152 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. F. THROUGH PENETRATING PRODUCT* -FLEXIBLE METAL PIPING -THE FOLLOWING TYPES OF STEEL FLEXIBLE METAL GAS PIPING MAY BE USED: 1. NOM 2 IN. (51 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. OMEGA FLEX INC 2. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. TITEFLEX CORP A BUNDY CO 3. NOM 1 IN. (25 MM) DIAM (OR SMALLER) STEEL FLEXIBLE METAL GAS PIPING. PLASTIC COVERING ON PIPING MAY OR MAY NOT BE REMOVED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. WARD MFG INC 3. FILL,VOID OR CAVITY MATERIAL* -CAULK OR SEALANT -MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. (16, 32,48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT LOCATION ON BOTH SIDES OF WALL. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW: +WHEN COPPER PIPE IS USED, T RATING IS 0 HR. 3M COMPANY -CP 25WB+ CAULK OR FB-3000 WT SEALANT, *BEARING THE UL CLASSIFICATION MARKING SECTION A-A 3 2 3 1A 1BA A B -PARALLEL TO ROOF STRUCTURE A - PERPENDICULAR TO ROOF STRUCTURE ROOF SHEATHING SUB-PURLIN FOUR (4) #10 SCREW 2-1/2" EMBED FOUR (4) #10 SCREW 2-1/2" EMBED ROOF SHEATHING SUB-PURLIN 2X BLOCKING (3) #8 S.M.S. 2-1/2" X 2-1/2" X 16 GA. CLIP EXISTING ROOF JOISTS MTL. STUD FRAMING (SEE SOFFIT DETAIL) 3 -#8 SCREWS WITH 1-1/2" EMBED 600 S 137 -43 MTL. STUDS BOTH SIDES OF STUD FRAMING ROOF SHEATHING (3) #8 S.M.S. 2-1/2" X 2-1/2" X 16 GA. CLIP (E) ROOF SHEATHING. 600 S 137 -43 METAL STUDS BOTH SIDES OF STUD FRAMING (3) #8 SCREWS WITH 1-1/2" EMBED EXISTING 2X JOISTS STUDS PERPENDICULAR TO FRAMING (WOOD DECK) STUDS PARALLEL TO FRAMING (WOOD DECK) 1 1/2" = 1'-0"12WALL - NON-INSULATED PIPE 1 1/2" = 1'-0"13WALL - INSULATED PIPE RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt INTERIOR PARTITION TYPES AND DETAILS A511 1 1/2" = 1'-0"7 FIRE EXTINGUISHER CABINET @ RATED WALL 1 1/2" = 1'-0"6 WALL PENETRATION DETAILS 1 1/2" = 1'-0"5WALL TYPE LH - LOW WALL 1 1/2" = 1'-0"2 WALL TYPE- FF - FULL HT. FURRING 1 1/2" = 1'-0"1WALL TYPE- FH - FULL HT 1 1/2" = 1'-0"3WALL TYPE- PH N O T U S E D 1 1/2" = 1'-0"4WALL TYPE- PW 3" = 1'-0"9 SOFFIT STUDS TO FRAMING (WOOD DECK) 3" = 1'-0"8BRACING DETAIL NOTE: REFER TO STRUCTURAL DRAWING FOR MORE DETAIL INFORMATION NOTE: REFER TO WALL BRACING DETAIL FOR THE FURR WALL ON DETAIL 5/A510 NOTE: 1. 12 GA, (MIN) HANGER VARIES MAY BE USED FOR UP TO AND INCLUDING 4'-0" X 4'-0" GRID SPACING ALONG MAIN RUNNERS. 2. PROVIDE 12 GA, HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN 8" FROM THE SUPPORT OR WITHIN 1/4 OF THE LENGTH OF THE END TEE, WHICHEVER IS LEAST, FOR THE PERIMETER OF HE CEILING AREA, END CONNECTIONS FOR RUNNERS WHICH ARE DESIGNED AND DETAILED TO RESIST THE APPLIED HORIZONTAL FORCES MAY BE USED IN LIEU OF THE 12 GA, HANGER WIRES. 3. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO MAIN HANGER SPACING, PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS REQUIRED AT ALL CEILING BREAKS,SOFFITS OR DISCONTINUOUS AREAS,HANGER WIRES THAT ARE MORE THAN 1 IN 6 OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. 4. CEILING GRID MEMBERS MAY BE ATTACHED TO NOT MORE THAN 2 ADJACENT WALLS. CEILING GRID MEMBERS LEAST 3/4" FREE OF OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE AND A MINIMUM OF 3/4" CLEAR OF WALL. 5. AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN THE RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A 16GA, WIRE WITH A POSITIVE MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER IS 12" OR LESS, THIS INTERLOCK IS NOT REQUIRED. 6. PROVIDE SETS OF FOUR 12 GA SPLAYED BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER. THE SLOPE OF THESE WIRES SHOULD NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND SHOULD BE TAUT WITHOUT CAUSING THE CEILING TO LIFT. SPLICES IN BRACING WIRES ARE NOT TO BE PERMITTED. 7. FASTEN HANGER WIRES WITH NOT LESS THAN THREE TIGHT TURNS, FASTEN BRACING WIRES WITH FOUR TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A DISTANCE OF 1-1/2" INCHES. HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE WIRE ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE FORCES ACTING ON THE WIRE. 8. SEPERATE ALL CEILING HANGING AND BRACING WIRES AT LEAST 6 INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUITS, ETC. IT IS ACCEPTABLE TO ATTACH LIGHTWEIGHT ITEMS, SUCH AS SINGLE ELECTRICAL CONDUIT NOT EXCEEDING 3/4" NOMINAL DIAMETER, TO HANGER WIRES USING CONNECTORS ACCEPTABLE TO OSHPD. 9. WHEN DRILLED -IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN REINFORCED CONCRETE FOR HANGER WIRES, 1 OUT OF 10 MUST BE FIELD TESTED FOR 200 POUNDS OF TENSION. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES, 1 OUT OF 2 MUST BE FIELD-TESTED FOR 440 POUNDS OF TEN-SION. SHOT IN ANCHORS IN CONCRETE ARE NOT PERMITTED FOR BRACING WIRES. IF ANY SHOT-IN OR DRILLED-IN ANCHOR FAILS, ALL ADJACENT ANCHORS MUST BE TESTED. 10. 1ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. 11. FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING LESS THAN 56 POUNDS MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY-DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO 12 GA, SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE, ALL 4 FT. X 4 FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACH CORNER. ALL FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES WEIGHING 56 POUNDS OR MORE MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN 4 TAUT 12 GA, WIRES EACH ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE REGARDLESS OF THE TYPE OF CEILING GRID SYSTEM USED. THE 4 TAUT 12 GA, WIRES INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE MUST BE CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE UNIT. 12. SUPPORT SURFACE-MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE FIXTURES (SEE ALSO NOTE 10 ABOVE PROVIDE ADDITONAL SUPPORT WHEN LIGHT FIXTURES ARE 8 FEET OR LONGER. 13. SUPPORT PENDANT-MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRCUTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE FIXTURES.(SEE ALSO NOTE 10 ABOVE) 14. ALL CEILING SUSPENSION SYSTEM COMPONENTS SHALL BE" HEAVY DUTY" TYPE WITH COMPONENTS PARTS AS LISTED BELOW. 15. ACOUSTICAL CEILING GRID EXPANSON JOINTS AS NEEDED DEPENDING ON CEILING AREA PER CODE. 16. STABILIZER BARS, CROSS TEES OR OTHER SUITABLE MEANS O PREVENT SPREADING SHALL BE PROVIDED WITHIN 8" OF EACH WALL 17. SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. 18. CEILING CLOUDS: PROVIDE HANGING WIRES, BRACE AND COMPRESSION STRUT AS DETAILED. IN ADDITION PROVIDE BRACE WIRES AND COMPRESSION STRUT AT EACH CORNER, REGARDLESS OF THE TYPE OF THE CLOUD. 12 GA. BRACING WIRE WITH MIN. TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE. TYPICAL SEE DETAIL 2FOR ANCHORING TO DECK 12 GA . VERT . HANGER WIRE SET CEILING GRID LEVEL PRIOR TO FASTENING TUBE COMPRESSION STRUT ( SEE DETAIL 16F) OR OPTIONAL EMT TUBING PER SCHEDULE ABOVE 2 #12 S.M.S CONNECTING COMPRESSION STRUT TO T-BAR GRID TYP. 12 GA. VERTICAL HANGER WIRE @ 4'-0" EACH WAY WITH MIN. 3 TIGHT TURNS IN 1 12" BOTH ENDS OF WIRE. SEE DETAIL 2 FOR ANCHORING TO DECK MAIN RUNNER CROSS RUNNERSUSPENDED CEILING NOTES: A SET OF FOUR SPLAY WIRES SHALL BE PROVIDED FOR EACH 96 S.F. OF TRIBUTARY AREA, FIRST SET OF SPLAY WIRES SHALL BEV WITHIN 4"-0" FROM ANY WALL, PROVIDE COMPRESSION STRUT AT EACH SPLAY WIRE LOCATION OPTIONAL ELECTRICAL METALLIC TUBING (EMT) SCHEDULE SIZE (DIAMETER)L (MAX. HEIGHT) 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 4'-0" 5'-2" 6'-6" 8'-6" 9'-10" 12'-0" STRUTS OTHER THAN EMT, MAY REQUIRE ENGINEERING CALCULATIONS,-CONTRACTOR IS RESPONSIBLE TO CONTRACT A LISENCED STRUCTURAL ENGINEER AND SUBMIT CALCULATIONS SLOT END OF TUBE OR POST TO FIT OVER MAIN RUNNER2" TYP.6" M A X . 16 I TYPICAL LAYOUT PLAN GRID CEILING 16 H 2'X4' GRID OR 2' X 5' GRID FIRE SPRINKLER HEADS , SPEAKERS, SMOKE DETECTORS,SIGNAL DEVICES, AND ANY OTHER CEILING FIXTURES SHALL BE PRECISELY LOCATED AS FOLLOWS: a ) IN ALIGNMENT WITH AIR DIFFUSERS AND EACH OTHER, AS SHOWN ABOVE . b) CENTERED WITHIN TILE, AS SHOWN ABOVE. 16 G 2'X2' GRID EQ E Q EQ EQ EQ EQ DIFFUSER LIGHT FIRE SPRINKLER HEAD,SMOKE DETECTOR OTHER CEILING MOUNTED TYPICAL,UNLESS INDICATED OTHERWISE 1' - 0 " EQ EQ EQ EQ PERIMETER PER DETAIL 16D & 16E 12 GA HANGER WIRE @ 4' X 4' OC MAIN RUNNERS COMPRESSION STRUT W/BRACE WIRES PER DETAIL 16F THIS SHEET EXPANSION JOINTS @ CORRIDOR INTERSECTIONS PROVIDE PER DETAIL 16B THIS SHEET CROSS RUNNERS LIGHT FIXTURE ATTACHED PER DETAIL 16C THIS SHEET NOTE: ALL MAIN AND CROSS RUNNERS TO BE HEAVY DUTY MEMBERS 4'-0" MAX @ RATED CLG 6'-0" MAX. COMP POST & BRACE WIRE 12'-0" MAX. 4' - 0 " M A X @ R A T E D C L G 6' - 0 " M A X . CO M P P O S T & B R A C E W I R E 12 ' - 0 " M A X . 6" MAX. SEE DETAIL 2 & 3 THIS SHEET FOR ALL WIRE & STRUT CONNECTIONS TO DECK 2" 16 E FIXED SIDE 16D FREE SIDE 2" 1" SEE DETAIL 16 FOR TYPICAL NOTES, CALLOUTS & DIMENSIONS 16 B GRID EXPANSION JOINT 16 C LIGHT FIXTURE SUPPORT 16 F COMPRESSION POST AND WIRE DETAIL ATTACH CEILING GRID MEMBERS TO NOT MORE THAN (2) ADJACENT WALLS BACK TO BACK 2" DEEP CHANNELS FINISH TO A CEILING GRID 12 GA HANGER WIRE W/ 3 TIGHT WRAPS IN 1 1/2" MAIN RUNNER CEILING TILE 0' - 3"8" MAX.8" MAX. PROVIDE 2 SUPPORT WIRE FOR LIGHTS LESS THAN 56 LBS & 4 FOR LIGHTS MORE THAN 56 LBS LIGHT FIXTURE CEILING SYSTEM HANGER WIRE PROVIDE MAIN RUNNERS AT THE BOUNDARY OF THE CEILING SYSTEM. PROVIDE DIRECT ATTACHMENT FROM THE LIGHT FIXTURE TO THE MAIN RUNNERS CEILING SYSTEM HANGER WIRE SLOTTED ANGLE SPACER W/ HORIZ 6d RINGSHANK HEAD TOWARD C.L OF SPAN.(ALT LOCATION W/OUT SPAN.(ALT LOCATION W/OUT 3/4" HANGER WIRE #12 SCREWS 1 1/4" LONG @ EACH STUD (3) TIGHT TURNS IN 1/2" GRID MEMBER MAIN OR SECONDARY PERIMETER ANGLE TO MATCH CEILING SYSTEM POP REVIT CEILING TILE LESSER OF 8" MAX OR 1/4 RUNNER LENGTH 1" COMPRESSION POST - METAL RACK 2 1/2" X 18 GA 12 GA HANGER WIRE W/4 TIGHT WRAPS IN 1 1/2" MAIN RUNNER (4) 12 GA BRACE WIRES W/3 TIGHT WRAPS IN 1 CEILING TILE CROSS RUNNERS45° MAX.4 5 ° M A X . 7' - 0 " M A X . SUSPENDED CEILING PER CBC SECTION 803.9.1.1, 1613.1 & ASCE 7-10 13.5.6: a. A HEAVY TYPE OF T-BAR CEILING SHALL BE USED. b. THE WIDTH OF PERIMETER CLOSURE ANGLE SHALL BE 2”MINIMUM IN WIDTH. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A MINIMUM 0.75”CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE. c. FOR CEILING AREA EXCEEDING 1,000 SQUARE FEET, HORIZONTAL RESTRAINT OF THE CEILING TO THE STRUCTURAL SYSTEM SHALL BE PROVIDED. THE TRIBUTARY AREAS OF THE HORIZONTAL RESTRAINTS SHALL BE APPROXIMATELY EQUAL. d. FOR CEILING AREA EXCEEDING 2,500 SQUARE FEET, A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2,500 SQUARE FEET SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSES ARE PERFORMED OF THE CEILING BRACING SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONSTRATE CEILING SYSTEM PENETRATIONS AND CLOSURE ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERAL DISPLACEMENT. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLES IN ACCORDANCE WITH ITEM B AND HORIZONTAL RESTRAINTS OR BRACING IN ACCORDANCE WITH ITEM C. e. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, PENETRATIONS SHALL HAVE A 2”OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THE CEILING TITLE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1”IN ALL HORIZONTAL DIRECTIONS IS PERMITTED. f. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. g. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. h. SUSPENDED CEILINGS SHALL BE SUBJECT TO PERIODIC SPECIAL INSPECTION REQUIREMENTS. THE INSPECTION ENTAILS MANUFACTURER CERTIFICATION OF COMPONENT. 2" MAX.2" MAX. VARIES 3" 3/4"3" 4" ARMSTRONG EXPANSION SLEEVE ARMSTRONG SEISMIC JOINT CLIP - ATTACHMENT PER MANUFACTURE RECOMMENDATIONS CEILING SYSTEM HANGER WIRE CEILING SYSTEM PROVIDE MAIN RUNNERS AT THE BOUNDRY OF THE CEILING SYSTEM. PROVIDE DIRECT ATTACHMENT FROM THE LIGHT FIXTURE TO THE MAIN RUNNERS CEILING SYSTEM HANGER WIRE LIGHT FIXTURE PROVIDE (2) SUPPORT WIRES FOR LIGHTS LESS THAN 56 LBS & (4) FOR LIGHTS MORE THAN 56 LBS MIN FIXTURE SPACE TO PREVENT CONFLICT BETWEEN ADJ FIXTURES OR WALLS DURING MAX ALLOWABLE SWING COUPLING NUT SUSPENSION CABLE OR ROD -45° MAX SWING ALLOWED THREADED ROD EXP BOLT (4) BRACE WIRES BRACE WIRE STEEL CLIP 3' WIDE x 4" LONG x 12 GA WALL STUD (2) #12 SCREWS x 1" LONG 4" STUD x 16 GA. (2) #8 x 1/2" SELF TAPING SCREWS 4" MI N . 3 3 / 4 " MI N . BRACE WIRE WALL STUD 12 GA STEEL CLIP (4) #12 SELF TAPING SCREWS x 1" LONG 1-1/ 4 " M I N . 1-1/4" MIN. E M B E D WITHIN 2'-0" 15C COMPRESSION STRUT TO STRUCTURE 3" = 1'-0" 15B BRACE WIRE TO STRUCTURE 3" = 1'-0" 15A HANGER WIRE TO STRUCTURE 3" = 1'-0" 15D BRACE WIRE IN PURLIN 3" = 1'-0" SPLAYED BRACE WIRE 3" X 1/4" CLOSED SCREW EYE (ESR-4272) WITH MIN. 1-1/4" INTO WOOD AT ANGLE OF THE WIRE 3 TIGHT TURNS IN 1 1/2" 45° MAX 3 TIGHT TURNS IN 1 1/2" VERTICAL HANGER WIRE WOOD SHEATHING WOOD FRAMING/ BLOCKING WHERE REQUIRED 3" X 1/4" CLOSED SCREW EYE (ESR-4272) WITH MIN. 1-1/4" INTO WOOD AT ANGLE OF THE WIRE WOOD SHEATHING (WOOD DECK)(WOOD DECK)(WOOD DECK) PLEASE NOTE: PANELIZED WOOD ROOF SYSTEM: 1.SECURE WIRES TO WOOD BEAMS/ METAL JOIST AS OCCURS. DO NOT ANCHOR FROM 2X4 SUB-PURLINS. CONTRACTOR MAY ANCHOR WITHIN 2'-0" OF SUPPORT MEMBER WHERE 2X6 SUB-PURLIN ARE PROVIDED. SEE DETAIL 15D 2.PROVIDE 2X6 BLOCKING WHERE REQUIRED. SUPPORT MEMBER 2X6 SUB-PURLIN WOOD SHEATHING WOOD FRAMING/ BLOCKING WHERE REQUIRED #10 SCREW EA SIDE CUT FLANGE & BEND COMPRESSION POST WOOD SHEATHING 2-#10 W/ 1 1/2" EMBED SCREWS WOOD FRAMING/ BLOCKING WHERE REQUIRED 2" (2) #10 SCREWS @ BLOCKING #8 SCREWS EACH SIDE ROOF SHEATHING2X BLOCKING @ 24" O.C. WITH 'U' HANGER STUDS @ 16" O.C. -SEE 1/A510 2"ROOF SHEATHING #8 SCREW EACH SIDE 16 GA. CONT. METAL TRACK (2) #10 SCREWS @ 24" O.C. 2X FRAMING STUDS @ 24" O.C. -SEE 1/A510 250S125-33 @ 16" OC 400S125-33 @ 16" OC 400S125-33 @ 12" OC 400S162-33 @ 16" OC 600S137-33 @ 16" OC 600S162-33 @ 12" OC 600S162-54 @ 12" OC 14'-0" 12'-5" 10'-2" 10'-2" 8'-6" 7'-10" 6'-11" UNBRACED BRACED @ MIDSPAN 8'-9" 10'-11" 11'-11" 13'-9" 14'-6" 18'-0" 20'-0" CEILING JOIST SPAN TABLE ALLOWABLE SPANS LEDGER; 16 GA. CONT. MTL TRACK (3) #8 S.M.S. PER STUD STEEL STUD WALL, SEE PLAN CEILING JOIST FRAMING, SEE SCHEDULE 1.ISS-ESR-3064P (20 GA. STUDS, L/360, 13 PSF) 2.VERIFY LOADING: MAXIMUM JOIST SPACING IS 1'-4" O.C. #8 SCREWS T & B GRID MAIN BEAM HANGER WIRE GRID SYSTEM CROSS TEE 5/8" GYPSUM BOARDEXPANSION JOINT WALL ANGLE MAIN BEAM ADAPTER CLIP 5/8" GYPSUM BOARD7/8" 8" MAX HANGER WIRE (3) TIGHT TURNS IN 1 1/2" #12 SCREWS X 1 1/4" LONG @ EACH STUD ATTACH CEILING GRID MEMBERS TO NOT MORE THAN (2) ADJACENT WALLS (IR-M3-1.4) SEISMIC PERIMETER CLIP SCREW TIGHTENED THROUGH MAIN RUNNER WEB RESTRICTING SEPARATION FROM WALL MOLDING (ICC# ESR-1222) CEILING TILE MAIN OR CROSS TEE 3/4" 8" MAX CEILING TILE WALL ANGLE 1 1/2" TOTAL TRAVEL HANGER WIRE 2" MAX. 2" MAX. 4 5 ° M A X . 45° MAX. CROSS RUNNERS GYPSUM BOARD (2) #12 SCREWS (4) 12 GA. BRACE WIRES WITH 3 TIGHT WRAPS IN A 1 1/2" DISTANCE MAIN RUNNER 12 GA. HANGER WIRE WITH 4 TIGHT WRAPS IN A 1 1/2" DISTANCE SEE DETAIL 15 THIS SHEET FOR ALL WIRE & STRUT CONNECTIONS TO DECK COMPRESSION POST -SEE TABLE IN DETAIL 21 THIS SHEET. HANGER & BRACE WIRE SHALL BE WITHIN 2" OF COMPRESSION POST 7' -0" M A X . 2" MAX. 2" MAX. 4 5 ° MA X . 4 5 °M A X . CROSS RUNNERS CEILING TILE (2) #12 SCREWS (4) 12 GA. BRACE WIRES WITH 3 TIGHT WRAPS IN A 1 1/2" DISTANCE MAIN RUNNER 12 GA. HANGER WIRE WITH 4 TIGHT WRAPS IN A 1 1/2" DISTANCE SEE DETAIL 15 THIS SHEET FOR ALL WIRE & STRUT CONNECTIONS TO DECK COMPRESSION POST -SEE TABLE IN DETAIL 21 THIS SHEET. RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt TYPICAL CEILING DETAILS A515 1 1/2" = 1'-0"1TYPICAL T-BAR CEILING #1 1/4" = 1'-0"2 TYPICAL T-BAR CEILING DETAIL 4 1 1/2" = 1'-0"3TYPICAL T-BAR CEILING 3" = 1'-0"4 GRID EXPANSION JOINT (ACT) 3" = 1'-0"5 LIGHT FIXTURE SUPPORT (ACT & GYP. BD.) 3/4" = 1'-0"6PENDANT FIXT. BRACE 1" = 1'-0"7ATTACHED BETWEEN STUDS 1" = 1'-0"8ATTACHED TO STUDS 3" = 1'-0"9 ATTACHMENT TO DECK STRUCTURE 3" = 1'-0"10 STUDS PARALLEL TO FRAMING (WOOD DECK) 3" = 1'-0"11 STUDS PERPENDICULAR TO FRAMING (WOOD DECK) 1" = 1'-0"12 CEILING FRAMING(NON-LOAD BEARING) 3" = 1'-0"13EXPANSION JOINT (GYP. BD.) 3" = 1'-0"14 GRID ATTACHMENT (GYP. BD.) 3" = 1'-0"15 GRID ATTACHMENT (ACT FIXED SIDE) 3" = 1'-0"16 GRID ATTACHMENT (ACT FREE SIDE) 3" = 1'-0"17 COMPRESSION POST & WIRE (GYP. BD.) 3" = 1'-0"18 COMPRESSION POST & WIRE (ACT) 1/ 2 " 1/ 4 " HOLLOW MTL. DR. CONT. 1/2" PREMOLDED SLOPE PAVING AWAY SEE SPEC'S. FROM DOOR, 2% MAX. EXP. JOINT FILLER W/DOOR BOTTOM BEYOND FACE OF WALL 2 1 FIN. CONC. FLR. GROUT THRESHOLD SADDLE DOOR FRAME PRESSED MET. THRESHOLD SOLID SEE SPECS. DR . H E I G H T FOR FRAMING SEE STRUCTURAL DRAWINGS GYPSUM BOARD 1/2" HOLLOW METAL FRAME FRAME ANCHOR CONT. WEATHER- STRIPPING 1 15/16"VARIES 1 15/16" FOR WALL THICKNESS SEE FLOOR PLAN EXT. CEM. PLASTER O/ PLYWOOD SHEATHING CONT. SEALANT CONT. METAL DRIP, PAINT TO MATCH DOOR FRAME DOOR, SEE SCHEDULE AND SPEC'S. 1/ 4 " 2" 1 3 / 4 " 5/ 8 " FRAME ANCHOR CONT. WEATHER- STRIPPING 1 1 5 / 1 6 " 1 1 5 / 1 6 " VA R I E S FO R W A L L T H I C K N E S S SE E F L O O R P L A N H.M. DOOR SEE SCHED. 1/4"5/8" 2" EXTERIOR INTERIOR 1/ 2 " METAL FRAME GYPSUM BOARD BATT INSULATION EXT. CEM. PLASTER O/ PLYWOOD SHEATHING CONT. SEALANT & BACKER ROD ℄OF STOREFRONT AND WALL STUDS GYP. BD. 1X CONT. NAILER 1/4" SHIM CONTINUOUS CORNER BEAD CONT. CAULKING EXT. CEM. PLASTER O/ METAL LATH O/ BLD'G PAPER O/ PLYWOOD SHEATING CEILING / SOFFIT WHERE OCCURS CONT. DRIP SCREED-PAINT CONT. SEALANT, TYP. COLOR TO MATCH STOREFRONT FACE OF PLASTER BEYOND ANODIZED ALUMINUM STOREFRONT FRAME W/ DBL. CLEAR GLASS MATCH EXISTING 4 1/2" WALL PARTITION - SEE FLOOR PLAN FOR WALL TYPESDOOR SEE SCHEDULE HOLLOW METAL FRAME FRAME ANCHOR 1 3/4" SE E F L O O R P L A N F O R W A L L T Y P E S VA R I E S DO O R H E I G H T HOLLOW METAL FRAME FRAME ANCHOR SEE PLAN FOR WALL TYPES FOR FRAMING SEE STRUCTURAL DRAWINGS DOOR, SEE SCHEDULE 1 3 / 4 " 1/2" SEE FLOOR PLAN FOR WALL TYPES VARIES FLOORING MATERIAL SEE FINISH PLAN HOLLOW METAL FRAME (HM) DOOR TRANSITION AS OCCURS (SEE FINISH SCHEDULE) LINE OF FLOOR MATERIAL TRANSITION, WHERE OCCURS DOOR - SEE SCHEDULE 1/2" SEE WALL TYPES VARIES 1/2" A B C D TG TG TEMP GLASS TEMP GLASS TYPE SPECIFICATIONS REMARKS A STOREFRONT • (2) EA. FLOOR PIVOT SET • (2) EA. TOP PIVOT SET • (4) EA. TAPERED HEAD MORTISED CYLINDER • (1) GLASS MOUNTED PATCH LOCK • (1) GLASS MOUNTED PATCH KEEPER • (2) PER DOOR LADDER STYLE DOOR PULLS • DOOR CLOSERS • 10" BOTTOM RAIL B BACK DOOR • 1 EA. PANIC HARDWARE: BEST ACCESS 93K-7-N-15-D-S3-US19. • 1 EA. VIEWER: IVES U698 • 1 EA. CLOSER: CORBIN RUSSWIN DC3200 US19 CLOSER WITH SILVER ALUMINUM FINISH. • 4 EA. HINGE: TA2714TB, 4-1/2" X 4-1/2". FULL MORTISE, 5 KNUCKLE STANDARD WEIGHT WITH BALL BEARINGS. • 4 EA. SILENCERS: IVES SR64 (4 PER DOOR) • 2 EA. KICKPLATE: IVES 8400-PA28-12" • 1 EA. WALLSTOP: IVES WS407CVX • 1 EA. THRESHOLD AS REQUIRED • 1 EA. SMOKE SEAL: REESE DS78A NEOPRENE SEAL, AS REQUIRED • PROVIDE WEATHER SEALS AND AN INSULATED HOLLOW METAL DOOR AT EXTERIOR LOCATIONS ONLY. C TOILET ROOM • 1 EA. PRIVACY LATCHSET: BEST ACCESS 93K-7-L-15-D-S3-US19. • 1 EA. CLOSER: CORBIN RUSSWIN DC3200 689 CLOSER WITH SILVER ALUMINUM FINISH. • 3 EA. HINGE: TA2714TB, 4-1/2" X 4-1/2". FULL MORTISE, 5 KNUCKLE STANDARD WEIGHT WITH BALL BEARINGS. • 3 EA. SILENCERS: IVES SR64 (3 PER DOOR) • 2 EA. KICKPLATE: IVES 8400-PA28-12" • 1 EA. WALLSTOP: IVES WS407CVX (USE TRIMCO FLOOR STOP #1231-626 AS REQUIRED) • OWNER PROVIDED CORES • PROVIDE TOILET ROOM SIGNAGE D SALES/STOCKROOM • 1 EA. PASSAGE LATCHSET: BEST ACCESS 93K-7-N-15-D-S3-US19. • 1 EA. CLOSER: CORBIN RUSSWIN DC3200 A1* 689 CLOSER WITH SILVER ALUMINUM FINISH WITH HOLD OPEN ARM AT 90 DEGREES (USE ON NON-RATED DOORS ONLY -SEE FIRE DOOR REQUIREMENT BELOW FOR RATED DOORS) • 3 EA. HINGE: TA2714TB, 4-1/2" X 4-1/2". FULL MORTISE, 5 KNUCKLE STANDARD WEIGHT W/ BALL BEARINGS. • 3 EA. SILENCERS: IVES SR64 (3 PER DOOR) • 2 EA. KICKPLATE: IVES 8400-PA28-12" • 1EA. WALLSTOP: IVES WS407CVX (USE TRIMCO FLOOR STOP #1231-626 AS REQUIRED) • FIRE DOOR (RATED) REQUIREMENT:PROVIDE 1 EA. CLOSER: CORBIN RUSSWIN DC3200 689 CLOSER WITH SILVER ALUMINUM FINISH WITH REGULAR NON-HOLD OPEN ARM. PROVIDE ON RATED DOORS ONLY AS SHOWN ON DOOR SCHEDULE • GC TO INSTALL "EMPLOYEE ONLY" SIGNAGE GC TO VERIFY THE EXISTING DOOR HARDWARE AND MATCH THE EXISTING DOOR COLOR AND TYPE (E) FLOOR SLAB DOOR. REFER TO DOOR SCHEDULE CORIAN 1/2"x2" TRANSITION THRESHOLD. DUPONT "NATURAL COLOR" CORIAN SEALED CONC FLOOR 2 1 MA X 1/ 2 " TILE. REFER TO FINISH SCHEDULE A. EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. B. NOT USED. C. ALL REMOVED (DEMOLISHED) DOORS TO BE RE-USED OR RELOCATED WHEN POSSIBLE. SEE PLAN FOR RELOCATION NOTES. STORE ALL DOORS WITH FRAMES, TRIM AND HARDWARE UNTIL COMPLETION OF THE WORK.. D. A EXIT DOOR(S) SHALL BE A MIN. OF 3'-0" X 7'-0" WITH A MINIMUM SWING OF NINETY (90) DEGRESS. WIDTH & HEIGHT OF REQUIRED EXIT DOORWAYS TO COMPLY WITH C.B.C. 1003.3.1 AND 1005.1. E. CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING DOOR FRAME UNITS, SCHEDULED FOR NEW DOORS, LOUVRES, PANELS ETC. F. ALL NEW DOOR FRAMES TO BE BY 'TIMELY', FINISH AND COLOR TO MATCH EXISTING WITH SQUARE-EDGED TRIM (NOT TAPERED). G. PAINT ALL FRAMES, UNLESS OTHERWISE NOTED. H. IF THE DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES (75MM) FROM THE LATCH, MEASURED TO THE LANDING EDGE OF THE DOOR. J. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS (38N) FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS (66.72N), PER SECTION 1133B.2.5 K. NOT USED. L. BRAILLE SYMBOLS: CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE SYMBOLS ARE SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10 INCH (2.54 MM) ON CENTERS IN EACH CELL WITH 2/10 INCH (5.08 MM) SPACE BETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH (0.635 MM) ABOVE THE BACKGROUND. ALL SIGNS AND IDENTIFICATION SHALL COMPLY WITH TITLE 24, SECTION 1117B.5-1117B.5.10 M. PROVIDE ROOM SIGNS FOR ALL ROOMS. SEE INTERIOR SIGN PROGRAM BY OTHERS. N. NOT USED. O. UNDERCUT DOORS ONLY AS REQUIRED PER MECHANICAL PLANS, OR AS OTHERWISE NOTED. AL ALUMINUM AN ANODIZED CL CHAIN LINK CS LEAR SEALED CTG CLEAR TEMPERED GLASS (E) EXISTING FF FACTORY FINISH FL FIRELITE GLASS FRP FIBERGLASS REINFORCED POLYESTER GA GALVANIZED HC HOLLOW CORE HF HOLLOW METAL SLIDING FOLDING HM HOLLOW METAL STEEL LG LEADED GLASS (N) NEW NR NON RATED PT PAINT PC POWDER COATED PG PAINT GRADE WOOD PH PANIC HARDWARE PL PLASTIC LAMINATE PO POLISHED PLATE GLASS R REUSE / RELOCATE SC SOLID CORE SG STAIN GRADE WOOD ST STEEL SST STAINLESS STEEL TG TEMPERED GLASS V VINYL WD WOOD WI WROUGHT IRON WG WIRE GLASS DOOR NUMBER FROM TO DIMENSION TYPE DOOR FRAME HARDWARE DETAIL REMARKS WIDTH HEIGHT MATERIAL FINISH MATERIAL FINISH HEAD JAMB THRESHOLD 01 ENTRY LOBBY 6' - 0" 7' - 8 1/4" B AL FF AL FF A 9/- NEW STOREFRONT DOOR COLOR AND STYLE TO MATCH EXISTING 02 WAITING 3' - 0" 7' - 0" D AL FF AL FF A 9/- NEW STOREFRONT DOOR COLOR AND STYLE TO MATCH EXISTING 03 KITCHEN 3' - 0" 7' - 0" A HM PT HM PT B 5/- 6/- 9/- EXTERIOR DOOR 04 SEATING SERVICE COUNTER 3' - 0" 7' - 0" C N/A N/A N/A N/A CASED OPENING WITH JAPANESE STYLE DOOR CURTAIN 05 KITCHEN SUSHI PREP. AREA 4' - 0" 8' - 0" C N/A N/A N/A N/A CASED OPENING 06 RETAIL TOILET 3' - 0" 7' - 0" A HM PT HM PT C 1/- 2/- 10/- 07 RETAIL TOILET 3' - 0" 7' - 0" A HM PT HM PT C 1/- 2/- 10/- 08 RETAIL OFFICE/STORAGE 3' - 0" 7' - 0" A HM PT HM PT D 1/- 2/- 09 SUSHI PREP. AREA RETAIL 3' - 0" 7' - 0" C N/A N/A N/A N/A CASED OPENING WITH JAPANESE STYLE DOOR CURTAIN E01 POP-UP 3' - 0" 7' - 0" D AL FF AL FF A (E) (E) 9/- EXISTING STOREFRONT DOOR TO REMAIN. REPAIR AS REQUIRED. PROVIDE NEW LOCK RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt DOOR SCHEDULES & DETAILS A601 3" = 1'-0"4STOREFRONT HEAD 3" = 1'-0"5EXTERIOR DOOR HEAD 3" = 1'-0"6EXTERIOR DOOR JAMB GENERAL NOTESLEGEND 6" = 1'-0"2DOOR JAM (HM) 6" = 1'-0"1DOOR HEAD (HM) 6" = 1'-0"3 TYPICAL INTERIOR DOOR THRESHOLD DOOR HARDWARE DOOR SCHEDULE 6" = 1'-0"10TILE/ CONC. TRANSITION 3" = 1'-0"9THRESHOLD DETAIL (GC TO SUBMIT CUT SHEET FOR REVIEW) NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. A701 5 3 42 7' - 9 1/2"6' - 2"7' - 7" 1' - 6" 4' - 0 " 6"3' - 6" 4' - 0 " 1' - 0 " 1' - 6"1' - 6" 4' - 0 " 2' - 6" 4' - 0 " 5' - 0" 4' - 8 " R 2 ' - 6 " 1' - 6" 3' - 0 " 4" 1' - 6" 12 11 1310 121310 5 1 1 1 1 2% SLOPE 2% SLOPE 14 1 2 FINISH FLOOR 0' -0" CEILING 9' -0" 3' - 0 " TILE TILE 13-1/2" MIN. 17 " M A X . 11 12 54" MIN, 48" MIN.12" MAX. 19 " M A X 17 " M I N 1 4 FINISH FACE OF WALL FINISH FLOOR 0' -0" CEILING 9' -0" 3' - 4 " TILE TILE17" - 18" 12" MIN 6" MAX.3' - 6" 8 18" MIN 63 10 13 FINISH FACE OF WALL 12 1 2 1- 1 / 2 " M I N FINISH FLOOR 0' -0" CEILING 9' -0" TILE TILE 9" 40 " M A X T O R E F L E C T I V E S U R F A C E 1 10 34 " M A X . 29 " M I N . 27 " M I N . CO U N T E R O R L A V . 40 " M A X W H E N M O U N T E D O V E R 25" MAX. FINISH FACE OF WALL 13 FINISH FLOOR 0' -0" CEILING 9' -0" TILE TILE 11 17 " M A X . 17" - 18" FINISH FACE OF WALL G404 12 TYP. B-6867 TOILET PAPER HOLDER DOUBLE ROLL DISPENSER BOBRICK STAINLESS STEEL B-4221 TOILET SEAT COVER DISPENSER CONTURA SERIES SURFACE MOUNTED DISPENSER 1 1/4"Ø STAINLESS STEEL BOBRICK B-5806 SERIES 42" GRAB BARS BOBRICK B-5806 SERIES 48" GRAB BARS 1 1/4"Ø STAINLESS STEEL BOBRICK B-254 SANITARY NAPKIN DISPOSAL BOBRICK 1 2 3 4 5 CODEITEM NO.MANUF.COLORNAMEDESCRIPTION 52060 SOAP DISPENSER SURFACE MOUNTED DISPENSER GEORGIA PACIFIC6 PAPER TOWEL DISPENSER SURFACE MOUNTED DISPENSER 7 SURFACE MOUNTED RECEPTACLE SATIN STAINLESS STEEL -GEORGIA PACIFIC59488A FRAMED MIRROR SURFACE MOUNTED CHANNEL FRAME B-1658 BOBRICK SANITIZER DISPENSER SURFACE MOUNTED DISPENSER 9 GEORGIA PACIFIC52057 STAINLESS STEEL STAINLESS STEEL - STAINLESS STEEL - STAINLESS STEEL 605B215 BATTERY POWER SENSEMATIC FAUCET (ADA COMPLIANT) INNSBROOK SELECTRONIC 0.5 GPM TOUCHLESS FAUCET STAINLESS STEEL BATTERY POWER URINAL FLUSHMETER AND URINAL AMERICAN STANDARD WITH SLOAN SOLIS 0.125 GPF SENSOR ACTIVATED URINAL FLUSHOMETER CADET TWO PIECE PRESSURE 1.1 GPF WITH SEAT AMERICAN STANDARD #5503A00B TOILET (ADA COMPLIANT) 10 11 12 CODEITEM NO.MANUF.COLORNAMEDESCRIPTION WHITE WHITE6590525.020 / 3370010 2467.100 LUCERNE™ WALL-HUNG LAVATORY SINK (ADA COMPLIANT) AMERICAN STANDARD 13 WHITE0355.041 VERSATILE WALL MOUNT BI-LEVEL ADA COOLER FILTERED REFRIGERATED S/S HIGH/LOW DRINKING FOUNTAIN (ADA COMPLIANT SEE 11/G404) ELKAY14LIGHT GRAY GRANITELZSTL8LC AMERICAN STANDARD AMERICAN STANDARD AMERICAN STANDARD RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt ENLARGED TOILET ROOM PLAN AND ELEVATIONS A701 1/2" = 1'-0"1ENLARGED TOILET ROOM 1/2" = 1'-0"2TOILET ROOM ELEVATION 1/2" = 1'-0"3TOILET ROOM ELEVATION 1/2" = 1'-0"4TOILET ROOM ELEVATION 1/2" = 1'-0"5TOILET ROOM ELEVATION ACCESORIES SPECIFICATIONS PLUMBING FIXTURE SPECIFICATIONS NOTE: PROVIDE RESTROOM SIGN. REFER TO SHEET 10/404 RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt 3D PERSPECTIVES (FOR REFERNACE ONLY) A801 23D PERSPECTIVE EAST 13D PERSPECTIVE WEST RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt 3D PERSPECTIVE (FOR REFERANCE ONLY) A80213D AXONOMETRIC RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt 3D PERSPECTIVE (FOR REFERANCE ONLY) A803 2NORTH/EAST AXON 3NORTH/WEST AXON 1SOUTH/EAST AXON 4SOUTH/WEST AXON WH HEALTH DEPARTMENT NOTES: 1. ALL EQUIPMENT, INCLUDING SHELVING, MUST BE SUPPORTED BY SIX (6) INCH HIGH, EASILY CLEANABLE LEGS, COMMERCIAL CASTERS, OR COMPLETELY SEALED IN POSITION ON A FOUR (4) INCH HIGH CONTINUOUSLY COVED BASE OR CONCRETE CURB. 2. THE JOCKEY BOX/ICE BIN(S) MUST HAVE A SLIDING COVER WHICH REMAINS CLOSED WHEN THE ICE IS NOT BEING ACTIVELY SCOOPED. 3. THE ONLY FOOD PREPARATION ALLOWED AT THE BAR IS THE PREPARATION OF BEVERAGES FOR IMMEDIATE SERVICE. 4. LOCKERS MUST BE INSTALLED ON SIX (6) INCH HIGH, EASILY CLEANABLE LEGS, CANTILEVERED OFF THE WALL, OR A MINIMUM FOUR (4) INCH HIGH CONTINUOUSLY COVED CURB OR PLATFORM. L-ANGLE LEGS ARE NOT ACCEPTABLE. A B C D EQ41 EQ41 EQ41 EQ41 EQ41 EQ41 EQ41EQ41EQ41EQ41 EQ49 EQ49 EQ21 EQ20 EQ23 EQ27 EQ32 EQ18 EQ32 EQ24 EQ24 EQ08 EQ27 EQ26 EQ17 EQ09 EQ15 EQ32 EQ19 EQ25 EQ24 EQ42 EQ42 EQ27 EQ35 EQ31 EQ25 EQ24 EQ24 EQ24 EQ24 EQ24 EQ32 30 " x 4 8 " 30 " x 4 8 " 30"x48"30"x48" ADJACENT TENANT AD J A C E N T T E N A N T EX T E R I O R EXTERIOR EX T E R I O R EQ06 EQ32.1 EQ52 EQ13 EQ13 POP-UP 13 OFFICE/STORAGE 12 RETAIL 9 ENTRY LOBBY 1 SEATING 2 WAITING 3 SERVICE COUNTER 5 KITCHEN 6 WALK-IN FRIDGE 8 SUSHI PREP. AREA 7 GRAM BAR 4 TOILET 11 TOILET 10 30 " x 4 8 " EQ04 EQ11 EQ11 EQ11 4' - 5 " 42 " H C O U N T E R EQ14 EQ07 EQ57 EQ57 EQ57 ELECTRICAL PANELS EQ59 EQ59 EQ59 EQ59 EQ59 EQ59 30 " x 4 8 " 30"x48" EQ55 EQ55 EQ55 EQ55 EQ30 EQ60 EQ60 EQ55 4' - 8 1/2" EQ62 EQ45 EQ46 EQ48 EQ01 EQ03 EQ02 EQ01 EQ02 EQ13 WAITING 3 EQ11 EQ11 EQ11 FIRE EXTINGUISHER E01 0706 08 05 04 03 01 02 EQ29 EQ43 EQ39 EQ33 EQ27 EQ09 EQ10 EQ63 EQ55 EQ55 EQ32 EQ32 EQ24 EQ58 EQ24.1 EQ54 EQ57 4' - 8 1 / 2 " LE D P A N E L W A L L DI S P L A Y S H E L F D I S P L A Y S H E L F EQ24 EQ50 EQ50 3' - 7" 14 ' - 0 " 4' - 0"2' - 8" 4' - 0" EQ64 EQ29 EQ47 EQ44 38 " H I G H C O U N T E R 34 " H I G H C H E C K O U T CO U N T E R 34 " H I G H C H E C K O U T CO U N T E R 34 " H I G H C O U N T E R 4' - 0" 34 " HI G H 30 " x 4 8 " 5' - 0" 7' - 7 1 / 2 " EQ32.2 EQ04 EQ04 EQ04 EQ65 EQ66 EQ32 EQ67 38 " H I G H CO U N T E R 38 " H I G H CO U N T E R 312 KITCHEN(584.33 SQ FT) + SUSHI BAR(234.39) + GRAM BAR(315.5) = 1,134.22 SQ. FT 1,134.22 X 25% = 283.56 SQ. FT (MINIMUM REQUIRED STORAGE) TOTAL STORAGE = 345 SQ.FT 96 LINEAL FT PER 100 SQAURE FT OF MINIMUM REQUIRED STORAGE 272.22 LINEAL FT OF SHELVING REQUIRED PROVIDED SHELVING = 275 LINEAL FT RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt EQUIPMENT PLAN AND SCHEDULE FS101 EQUIPMENT SCHEDULE # COUNT EQUIPMENT DESCRIPTION MANUFACTURER MODEL NO. SUPPLY BY INSTALL BY Comments EQ01 2 GRIDDLE ACCUTEMP GGF1201B4850-T1 OWNER G.C. EQ02 2 EQUIPMENT STAND INTERTEK ES-P3048 OWNER G.C. EQ03 1 WORKTOP REFRIGERATOR TRUE TWT-48-HC OWNER G.C. SELF-CONTAINED EQ04 4 UNDERCOUNTER REFRIGERATOR TURBO AIR MUR-48-N OWNER G.C. <varies> EQ06 1 REFRIGERATOR TRAULSEN RHT232WUT-FHS OWNER G.C. SELF-CONTAINED EQ07 1 FAUCET REGENCY 600FW86G G.C. G.C. EQ08 1 PREP TABLE EVEREST EPBNR3 OWNER G.C. EQ09 2 RICE COOKER RINNAI RER55ASN OWNER G.C. EQ10 1 RICE WARMER ZOJIRUSHI RDS-600 OWNER G.C. EQ11 3 DEEP FRYER PITCO PITCO35C+ OWNER G.C. EQ12 1 WALK IN COOLER AIRCOOLER COOLER AND FREEZER OWNER G.C. EQ13 2 AIR CURTAIN (36") CURTRON (AIR-PRO) AP-2-75-2-SS G.C. G.C. 1600 FPM EQ14 1 AIR CURTAIN (72") CURTRON (MICROSHIELD) MCS-72 G.C. G.C. 1600 FPM EQ15 1 EQUIPMENT STAND STEELTON 522SG3024 OWNER G.C. EQ17 1 4 BURNERS GAS RANGE WITH OVEN COOK RITE ATO-4B OWNER G.C. EQ18 1 THREE COMPARTMENT SINK GSW SE18183D G.C. G.C. EQ19 1 FAUCET T&S 5PR-8W12 G.C. G.C. EQ20 1 MOP SINK ADVANCE TABCO 9-OP-20+K-116 G.C. G.C. EQ21 1 FAUCET ADVANCE TABCO K-240 G.C. G.C. EQ23 1 UTILITY SHELF ADVANCE TABCO K-246 G.C. G.C. EQ24 10 WIRE SHELVING METRO 1848BR OWNER G.C. 5-SHELVES EQ24.1 1 WIRE SHELVING METRO 1836BR OWNER G.C. 5-SHELVES EQ25 2 WIRE SHELVING METRO 1860BR OWNER G.C. 5-SHELVES EQ26 1 PREP. SINK ADVANCE TABCO 93-1-24-18 G.C. G.C. EQ27 4 HAND SINK AERO MANUFACTURING HSDE G.C. G.C. EQ29 1 EXHAUST HOOD (9 FEET) CAPTIVEAIRE REFER TO MECHANICAL DRAWING G.C. G.C. EQ30 1 EXHAUST HOOD (13 FEET) CAPTIVEAIRE REFER TO MECHANICAL DRAWING G.C. G.C. EQ31 1 FAUCET ADVANCE TABCO K-101 G.C. G.C. EQ32 6 WORK TABLE ADVANCE TABCO TT-304-X 48" OWNER G.C. EQ32.1 1 WORK TABLE ADVANCE TABCO TT-304-X60" OWNER G.C. EQ32.2 1 WORK TABLE ADVANCE TABCO TTS-180X30" OWNER G.C. EQ33 1 UNDERCOUNTER REFRIGERATOR ATOSA MGF8406GR OWNER G.C. EQ35 1 ONE COMPARTMENT SINK AERO MANUFACTURING MF1-1818 G.C. G.C. EQ39 1 ICE MAKER, UNDERCOUNTER MANITOWOC ICE UYF0140A OWNER G.C. EQ41 10 GONDOLA ISLAND LOZIER WED44825LBS OWNER G.C. EQ42 2 DIGITAL KIOSK TBD TBD OWNER G.C. EQ43 1 SOFT SERVE FREEZER TAYLOR C723 OWNER G.C. EQ44 1 BLENDER VITAMIX COMMERCIAL THE QUIET ONE OWNER OWNER EQ45 1 ESPRESSO COFFEE MACHINE LA MARZOCCO LINEA CLASSIC S (2 GROUPS) OWNER G.C. EQ46 1 BAR & CAFE RINSER ESPRESSO PARTS EPPR724 G.C. G.C. EQ47 1 WATER BOILERS MARCO MT8 1000763 OWNER G.C. EQ48 1 COFFEE GROUNDER MAZZER MAJOR V OWNER OWNER EQ49 2 SIX TIER METAL LOCKER ASI Storage ASI 16121278 OWNER G.C. EQ50 2 STAND MIXER KITCHENAID KSM150PS OWNER OWNER EQ52 1 SANDWICH PREP REFRIGERATOR TRUE TSSU-60-16-HC OWNER G.C. SELF-CONTAINED EQ53 2 TRASH BIN TBD TBD OWNER G.C. EQ54 1 BAR SINK ELKAY BLH15C G.C. G.C. EQ55 7 COLD DISPLAY CASE 48" BLUEAIR TOAM-48-HC~NSL01 OWNER G.C. EQ57 4 POS SYSTEM TBD TBD OWNER OWNER EQ58 1 SANDWICH PREP. TABLE TURBO AIR MST-36-15-N6 OWNER G.C. EQ59 6 WIRE SHELVING METRO 2448BR OWNER G.C. EQ60 2 GONDOLA ISLAND LOZIER WED44825LBS OWNER G.C. EQ62 1 PREP. SINK ADVANCE TABCO 93-1-24-18 G.C. G.C. EQ63 1 FULL SERVICE REFRIGERATED CASE W/ GLASS HOWARD-MCRAY SC-CMS34N-12-LED OWNER G.C. SELF-CONTAINED EQ64 1 KNOCK BOX BARISTA BASICS KNOCK BOX 6"X5.5"X4" OWNER OWNER EQ65 1 MAKI CUTTER SUSHI ROBOTS ASM260CE OWNER OWNER EQ66 1 ROLL SUSHI MAKING MACHINE SUZUMO SVR-BXA-ET OWNER OWNER EQ67 1 COMPACT SUSHI MACHINE SUZUMO SSN-JLX OWNER OWNER GENERAL NOTES 1/4" = 1'-0"1EQUIPMENT PLAN STORAGE CALCULATIONS FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S S T O R E F R O N T NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 MECHANICAL LEAD SHEET M-00 MECHANICAL SHEET INDEX SHEET #SHEET NAME M-00 MECHANICAL LEAD SHEET M-01 MECHANICAL PLANS 2022 CALIFORNIA BUILDING CODE. 2022 CALIFORNIA MECHANICAL CODE. 2022 CALIFORNIA PLUMBING CODE. 2022 CALIFORNIA ENERGY CODE. 2022 CALIFORNIA ELECTRICAL CODE. 2022 CALIFORNIA FIRE CODE. 2022 CALIFORNIA GREEN BUILDING CODE WITH ALL AHJ AMENDMENTS. APPLICABLE CODE OUTSIDE AIR VENTILATION CALCULATION TOTAL AREA (SQFT)OCUPATION TYPE VENTILATION PER SQFT VENTILATION PER PERSON OCCUPANCY PER ARCH. FOH = 2,260 SQFT & BOH = 1,265 SQFT RESTURANT 0.18 & 0.12 CFM/SQFT 7.5 CFM/PERSON 6 FOR BOH & 55 FOR FOH (FOH) DINING: Vbz (M)= Rp X Pz + Ra X Az Vbz = 7.5 CFM/PERSON X 55 PERSON + 0.18 CFM /SQFT X 2260 SQFT = 819 CFM TOTAL REQUIRED OSA FOR THE SPACE 819 + 164 = 983 CFM TOTAL PROVIDED PER DESIGN 1,200 CFM THROUGH (E) RTU'S (300 CFM PER EACH) NOTES: CALCULATION ARE BASED ON TABLE 402.1 FROM CALIFORNIA MECHANICAL CODE. GRILLES AND REGISTERS SCHEDULE MANUFACTURER MODEL FINISH DESCRIPTION VOLUME DAMPER REMARKS PRICE INDUSTRIES AMCD AS PER ARCH/ID SQUARE FACE DIFFUSER YES NICK SIZE PER PLANS. NOTES: -INSTALL LINEAR DIFFUSER/GRILL WITH FACTORY PROVIDED PLENUM. -WHERE DIFFUSER/GRILL MANUFACTURED WITH RECTANGULAR OUTLET/INLET, INSTALL DUCT TRANSITION TO ROUND. -FINISHES SHALL BE PER ARCH./ID PLANS. -SPECIFIED DIFFUSER/GRILL CAN BE SUBSTITUTE WITH ANY APPROVED EQUAL. AIR BALANCE SCHEDULE UNIT TAG OUTSIDE AIR SUPPLY RETURN RELIEF BY BAROMETRIC DAMPER NOTES (E)RTU 300 300 300 CFM TO MAKE UP FOR GREASE HOOD SYSTEM WHEN ACTIVATED SCALE:1 CEILING REGISTER/DIFFUSER N.T.S M-02 GREASE HOOD DETAILS DUCT INSTALLATION & INSULATION SHALL COMPLY WITH 2022 T24 AND AS BELOW (REFER TO MANDATORY MEASURES ON SHEET M-03 FOR ADDITIONAL REQUIREMENTS): -DUCT LOCATED WITHIN DROP CEILING OR IN BETWEEN STRUCTURAL JOISTS SHALL HAVE A 1" INSULATION NOT LESS THAN R4.2 VALUE TO PREVENT CONDENSATION. -DUCT LOCATED IN UNCONDITIONED SPACE SHALL HAVE A MINIMUM OF 2" INSULATION AND NOT LESS THAN R8 VALUE. -DUCT LOCATED WITHIN VENTILATED ROOF ATTIC SHALL HAVE A MINIMUM OF 2" INSULATION AND NOT LESS THAN R8 VALUE. -EXPOSED DUCT SHALL BE SPIRAL PAINTED PER ARCH. PLANS. EXPOSED DUCT WORK TO CONDITIONED AREA'S SHALL BE PERMITTED TO BE INSTALLED WITHOUT INSULATION. -DUCT PLENUMS SHALL BE LINED WITH 1" INSULATION. -DUCT SUPPORT SHALL CONFIRM TO MANUFACTURER RECOMMENDATIONS, CMC & SMACNA GUIDELINES. -DUCT LOCATED WITHIN DROP CEILING OR STRUCTURAL JOIST SHALL BE PERMITTED TO HAVE THE LAST 5' OF RUN TO THE DIFFUSER OF FLEX DUCT THAT COMPLIES WITH CMC. -DUCT EXPOSED TO WEATHER SHALL HAVE A MINIMUM OF 2" INSULATION AND WRAPPED WITH APPROVED WEATHER PROTECTION MATERIAL SUCH AS ALUMINUM WRAP THAT IS ABLE TO PROTECT IT FROM WATER, SUN LIGHT AND UV LIGHT. DUCT CONSTRUCTION AND MATERIAL SCHEDULE 1,200 900 300 1,200 M-03 (BOH) KITCHEN: Vbz (M)= Rp X Pz + Ra X Az Vbz = 7.5 CFM/PERSON X 6 PERSON + 0.12 CFM /SQFT X 990 SQFT = 164 CFM PRICE INDUSTRIES CVD AS PER ARCH/ID RESTROOM DIFFUSER YES NICK SIZE PER PLANS. PRICE INDUSTRIES 10FF AS PER ARCH/ID PERFORATED RETURN YES NICK SIZE PER PLANS. PRICE INDUSTRIES 10FF AS PER ARCH/ID FILTERED RETURN NO NICK SIZE PER PLANS. RESTROOM EXHAUST FAN SCHEDULE EF TAG MANUFACTURER & MODEL NUMBER AREA SERVED LOCATION SONES HUMIDITY SENSOR ELECTRICAL EXHAUST (CFM) SP (IN.WG) OPERATING WEIGHT (LBS) NOTES V/PH WATTS EF-1/EF-2 PANASONIC FV-0511VK CEILLING 0.9 NO 0.30 20 1-4 NOTES: 1. FUSED DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR. 2. EXHAUST FAN TO BE INTERLOCKED WITH OCCUPANCY SENSOR OR LIGHT SWITCH. 3. INSTALL BACKDRAFT DAMPER. 4. REFER TO DETAIL 3/M-00 FOR CEILING EXHAUST FAN FOR INSTALLATION DETAILS. 120/1 11020RESTROOM SCALE:3 CEILING EXHAUST FAN DETAIL N.T.S M-04 EXPOSED CEILING SCALE:2 DUCT MOUNT ROUND DIFFUSER DETAIL N.T.S (E)RTU 900 300 300 CFM TO MAKE UP FOR GREASE HOOD SYSTEM WHEN ACTIVATED GREASE HOOD DETAILS GREASE HOOD DETAILS M-05 GREASE HOOD DETAILS M-06 GREASE HOOD DETAILS M-07 GREASE HOOD DETAILS M-08 GREASE HOOD DETAILS M-09 GREASE HOOD DETAILS M-10 GREASE HOOD DETAILS M-11 GREASE HOOD DETAILS M-12 GREASE HOOD DETAILS M-13 PRICE INDUSTRIES RCDE AS PER ARCH/ID ROUND DIFFUSER YES NICK SIZE PER PLANS. M-14 ENERGY COMPLIANCE FORMS M-15 ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS 1,200 900 300(E)RTU 300 300 CFM TO MAKE UP FOR GREASE HOOD SYSTEM WHEN ACTIVATED 1,200 900 300(E)RTU 300 80 CFM TO MAKE UP FOR GREASE HOOD & 200 TO MAKE UP FOR RR FANS ------KEF-1 --400 CFM TO MAKE UP FOR GREASE HOOD SYSTEM WHEN ACTIVATED ------KEF-2 --400 CFM TO MAKE UP FOR GREASE HOOD SYSTEM WHEN ACTIVATED ------MAU-1 4,960 400 CFM TO MAKE UP FOR GREASE HOOD SYSTEM WHEN ACTIVATED EXHAUST ------EF-1 --400 CFM TO MAKE UP FOR GREASE HOOD SYSTEM WHEN ACTIVATED ------EF-2 --400 CFM TO MAKE UP FOR GREASE HOOD SYSTEM WHEN ACTIVATED -- -- -- -- 2,300 3,900 -- 100 100 6,160 6,400 -2404,800 3,600 SPACE IS BALANCED BY A WALL BAROMETIRC DAMPER SCALE:4 GREASE HOOD 6" OVERHANG HORIZONTAL DETAIL N.T.S SCALE:5 GREASE DUCT ACCESS PANEL SPEC'S N.T.S EXHAUST FANS MUST BE INTERLOCKED WITH ASSOCIATED RTU. KITCHEN EXHAUST FANS MUST BE INTERLOCKED WITH MAKE UP AIR UNIT. A B C D KITCHEN 6 OFFICE/STORAGE 12 TOILET 10 TOILET 11 SUSHI PREP. AREA 7 SEATING 2 WAITING 3 ENTRY LOBBY 1 RETAIL 9 POP-UP 13 SERVICE COUNTER 5 GRAM BAR 4 WALK-IN FRIDGE 8 312 A B C D 1 32 MECHANICAL PLANS M-01 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 SCALE:1 MECHANICAL REFLECTED CEILING PLAN 1/4"=1'-0"SCALE:2 MECHANICAL ROOF PLAN 1/4"=1'-0" 1500500 FLOW RATE (CFM) 1000 0.00 0 0.50 PR E S S U R E D R O P ( i n . H 2 0 ) PRESSURE DROP VS. FLOW RATE FR A C T I O N A L E F F I C I E N C Y ( % ) 0 0.1 20 40 1.0 PARTICLE DIAMETER (UM) 10.0 EFFICIENCY VS. PARTICLE DIAMETER 60 80 100 1.00 1.50 2.00 2.50 3.00 3.50 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-02 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-03 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-04 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 ” ” SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-05 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-06 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-07 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 FLOATSWITCH Field Wiredand Piped Roof line InternalWaterSolenoid SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-08 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 ɸ SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-09 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-10 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-11 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 CUSTOMER APPROVAL TO MANUFACTURE: SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS ww w . c a p t i v e a i r e . c o m MASTER DRAWING So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m GREASE HOOD DETAILS M-12 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 7$%/E   9ER7I&$/ 'I67$N&E GRE$6E E;+$867 '8&7 7ERMIN$7I2N $N' 68332R7 'E7$I/ M-13 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 ENERGY COMPLIANCE FORMS M-14 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 ENERGY COMPLIANCE FORMS M-15 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK09/18/2025 2ND PLAN CHECK11/04/2025 ENERGY COMPLIANCE FORMS PLUMBING GENERAL NOTES 1.PLUMBING WORK SHALL COMPLY WITH 2022 CALIFORNIA BUILDING CODES AND AHJ AMENDMENTS. 2.PLUMBING EQUIPMENT SHALL BE APPROVED AND TESTED UNDER APPROVED AGENCY FOR THE AHJ. 3.EACH HORIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH A CLEANOUT AT ITS UPPER TERMINAL, AND EACH RUN OF PIPING, THAT IS MORE THAN 100 FEET IN TOTAL DEVELOPED LENGTH, SHALL BE PROVIDED WITH A CLEANOUT FOR EACH 100 FEET, OR FRACTION THEREOF, IN LENGTH OF SUCH PIPING. AN ADDITIONAL CLEANOUT SHALL BE PROVIDED IN A DRAINAGE LINE FOR EACH AGGREGATE HORIZONTAL CHANGE IN DIRECTION EXCEEDING 135 DEGREES. A CLEANOUT SHALL BE INSTALLED ABOVE KITCHEN SINK AND LAVATORY CONNECTION FITTING, SERVING EACH FIXTURE. 4.SANITARY SEWER LINE TO SLOPE @ 2% UNLESS NOTED OTHERWISE. 5.CONTRACTOR TO VERIFY POINT OF CONNECTION PRIOR ANY INSTALLATION. 6.ALL VALVES AND FITTING TO SAME SIZE AS PIPE SIZE. 7.FLOOR DRAINS SHALL HAVE A TRAP PRIMER. 8.UNIONS SHALL BE PROVIDED PRIOR TO ANY EQUIPMENT CONNECTION. 9.THE USE OF CPVC PIPING SHALL COMPLY WITH 2022 CPC 604.1.1. 10.THE USE OF PEX PIPING SHALL COMPLY WITH 2022 CPC 604.1.1. 11.HOT WATER PIPING INSULATION SHALL BE PER 2022 CALIFORNIA PLUMBING CODE 609.11.2: "HOT WATER PIPE INSULATION SHALL BE PER BELOW SCHEDULE. EXCEPTIONS: -PIPING THAT PENETRATES FRAMING MEMBERS SHALL NOT BE REQUIRED TO HAVE PIPE INSULATION FOR THE DISTANCE OF THE FRAMING PENETRATION. -HOT WATER PIPING BETWEEN THE FIXTURE CONTROL VALVE OR SUPPLY STOP AND THE FIXTURE OR APPLIANCE SHALL NOT BE REQUIRED TO BE INSULATED. 12.SLEEVES SHALL BE PROVIDED FOR PIPING PASSING THRU MASONRY OR CONCRETE FLOORS/WALLS. 13.PLUMBING FIXTURE SHALL MEET 2022 CALIFORNIA PLUMBING CODE REQUIREMENTS PER CHAPTER 4 AND CALIFORNIA GREEN CODE FIXTURE FLOW. 14.DOMESTIC WATER LINE SHALL BE DISINFECTED PER 2022 CPC 609.9. 15.WET VENT SHALL NOT EXCEED 6' IN LENGTH. 16.WATER PIPES AND FITTINGS WITH A LEAD CONTENT WHICH EXCEEDS 0.25% SHALL BE PROHIBITED IN SYSTEMS CONVEYING POTABLE WATER. (CPC604.2) 17.CONTRACTOR SHALL FIELD VERIFY UTILITIES POINT OF CONNECTION AND COORDINATE AT SITE AS NEEDED. 18.ALL NON COMPLIANT PLUMBING FIXTURES WITHIN THE BUILDING SCOPE SHALL BE REPLACED WITH WATER CONSERVATIVE PLUMBING FIXTURES PER SECTION 301.1.1 CALGreen & CPC 401.3 PLUMBING LEGENED AND ABBREVIATIONS SYMBOL ABBREVIATIO DESCRIPTION CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER HWR DOMESTIC HOT WATER RETURN SS SANITARY SEWER SS BG SANITARY SEWER BELOW GROUND SD STORM DRAIN SD BG STORM DRAIN BELOW GROUND V PLUMBING VENTS GAS STANDARD PRESSURE GAS MPG MEDIUM PRESSURE GAS PCD PRIMARY CONDENSATE SCD SECONDERY CONDENSATE HB HOSE BIB DN PIPE DOWN UP PIPE UP DS DOWNSPOUT P.O.C POINT OF CONNECTION RD ROOF DRAIN OD OVERFLOW DRAIN AD AREA DRAIN FD FLOOR DRAIN ED EMERGENCY DRAIN TD TRENCH DRAIN FS FLOOR SINK WCO WALL CLEAN OUT YCO YARD CLEAN OUT COTG CLEAN OUT TO GRADE FCO FLOOR CLEAN OUT SR SUD RELIEF IRR IRRIGATION ABV ABOVE BLW BELOW 2022 CALIFORNIA ENERGY CODE TABLE 120.3-A PIPE INSUALTION THICKNES IN INCHES OR R VALUE FLUID TEMPRETURE INSULATION CONDUCTIVITY NOMINAL PIPE SIZE BTU.in/(h X FT² X °F)MEAN RATING TEMPRETURE F <1 1 TO <1 1/2 1 1/2 TO <4 4 TO <8 >8 105-140 F 0.22-0.28 100 1 1.5 1.5 1.5 1.5 R-7.7 R-12.5 R-11 R-9 R-8 PLUMBING SHEET INDEX SHEET #SHEET NAME P-00 PLUMBING LEAD SHEET P-01 PLUMBING SITE PLAN PLUMBING FIXTURES MAX FLOW RATE HAND SINK PLUMBING FIXTURE MAX FLOW RATE 1.2 GPM @ 60 psi PUBLIC LAVATORIES 0.5 GPM @ 60 psi METERING FAUCET 0.25 GPC SHOWER HEAD 1.8 GPM @ 80 PSI WATER CLOSET 1.25 GPF URINAL 0.125 GALLONS KITCHEN FAUCET 1.8 GPM @ 60 PSI WATER PIPE SIZING THIS PROJECT SHALL COMPLY WITH THE: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA ENERGY CODE WITH ALL AHJ AMENDMENT. PIPE MATERIAL SCHEDULE DOMESTIC WATER (2 ) B A N D NO - H U B CA S T I R O N SC H E D U L E 80 P V C TY P E L CO P P E R SC H E D U L E 4 0 BL A C K S T E E L CP V C PV C AB S NOTES INSIDE C & H WATER ABV FLOOR UNDER SLAB THRU SLAB OUTSIDE MUST BE SLEEVED, PVC USED FOR EXTERIOR BUILDING SUPPLY MUST BE SLEEVED, PVC USED FOR EXTERIOR BUILDING SUPPLY SS, VENT & SD RISERS THRU ALL FLOORS BELOW SLAB (UNDERGROUND) NO HUB CAST IRON, 2-BAN- NO HUB COUPLINGS PVC DWV (AS APPROVED PER AHJ) CONDENSATE ABV FLOOR AS APPROVED PER AHJ INDIRECT WASTE ABV FLOOR AS APPROVED PER AHJ SERVICE PIPE MATERIAL PLUMBING LEAD SHEET P-00 WATER PRESSURE CALCULATION TY P E K CO P P E R GAS OUTSIDE OR EXPOSED INSIDE THE BUILDING SC H E D U L E 4 0 GA L V N I Z E D ST E E L PROVIDE DOUBLE WALL PIPING WITH VENT IF INSTALLED BLW SLAB AS APPROVED PER AHJ *INSTALLATION OF CPVC SHALL BE PER 2022 CPC 604.1.1 & 609.9 *INSTALLATION OF GAS PIPING SHALL BE PER 2022 CPC 1210.0. *ALL CPVC PIPING SHALL COMPLY WITH CHAPTER 15 FIRESTOP PROTECTION WHERE NEEDED. *USE CORZAN SCHEDULE 80 FOR WATER PIPES SIZE OF 212" AND LARGER. *USE FLOW GUARD GOLD CPVC 41 FOR WATER PIPES SIZES OF 2" AND SMALLER. *ALL EXPOSED GAS PIPING SHALL BE PROTECTED AGAINST CORRSION BY COATING OR WRAPPING WITH AN INERT MATERIAL APPROVED FOR SUCH APPLICATION. PER 2022CPC SECTION 1208.5.6 & 1210.1.3. *PVC SCHEDULE 40 FOR DCW UNDER SLAB ONLY, NOT ALLOWED WITHIN THE BUILDING. *COPPER TYPE L: FIRST 10' OF PIPE CONNECTION TO WATER HEATER OR WHEN PIPE EXPOSED OUTDOOR AND ROOF. AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 9/19/2025 1ST PLAN CHECK WATER HEATER CALC'S DEMAND CALC'S: (1) KITCHEN SINK (3 COMP)@ 45 GPH = 45 (4) KITCHEN SINK (PREP)@ 15 GPH = 60 (1) MOB SINKS @ 15 GPH = 15 (6) HAND SINK/ LAV @ 05 GPH = 30 TOTAL REQIURED = 150 GPH (N) RHEEM GAS TANK WATER HEATER (EF60T125E3NA) 196 GPH @ 60°F TOTAL OF SUPPLY HOT WATER . SCALE:3 FLOOR CLEAN OUT N.T.SSCALE:2 WALL CLEAN OUT N.T.SSCALE:1 PIPE PENETRATION THRU INTERIOR WALL N.T.S TOTAL WATER DEMAND DESCRIPTION VENTWASTE ROUGH-IN SERVICES ITEM FIXTURE GASHOTCOLDWATERWATER SYMBOL SERVICE LOCATION FUEL TYPE MANUFACTURER & MODEL ELECTRICAL VOLT PHASE (LBS) OPER. WEIGHT DESCRIPTION BTU INPUT (MBTUH)1ST HR RATING @ THERMAL EFFICIENCY 60°F RISE UEF BRADFORD WHITE EF60T125E3NA 60 GALLON ST 125,000 BTUH SCALE:4 WATER HEATER INSTALLATION DETIAL N.T.S WATER HEATER GENERAL NOTES: -COLD WATER WITHIN 10' OF WH TO BE COPPER AND INSULATED. -ALL HOT WATER AND HOT WATER RETURN TO BE INSULATED. -INSTALL PER MANUFACTURER RECOMMENDATIONS. -CIRCULATING PUMP SHALL HAVE A HOSE BIB ON EACH SIDE OF THE PUMP ALONG WITH ISOLATING VALVES GALVANIZED SHEET METAL DRAIN PAN STORAGE TANK TYPE ELECTRIC WATER HEATER SECURE WATER HEATER TO WALL WITH (2) 20ga x 1" WIDE GALVANIZED SHEET METAL SEISMIC STRAPS POP-OFF DRAIN LINE FULL SIZE OF UNIT CONNECTION PER CPC 608.5 THERMAL EXPANSION TANK BALL VALVE, TYP ASME RATED PRESSURE AND TEMPERATURE RELIEF VALVE 1" HOT WATER LINE VACUUM RELIEF VALVE CHECK VALVE 1" COLD WATER SUPPLY LINE TERMINATE TO THE MS WITH 2" AIR GAP CHECK VALVE CHECK VALVE 34" HOT WATER RETURN LINE 1" TMV-1 (LIMIT WATER TEMPERATURE AT 120°F - 10 GPM @ 5 PSI PRESSURE DROP) BALANCING VALVE BV-1 STRAINER CIRCULATING PUMP (E)FLOOR TOTAL GAS DEMAND AS SPECIFIED PER DEVELOPER/ARCHITECT.MAXIMUM FLOW 1.28 GPF / FLUSH TANK SYSTEMWATER CLOSET - ADA LAVATORY - ADA MODEL NUM.MARK WC L PLUMBING FIXTURE SCHEDULE DESCRIPTION COLDVENTSS HOT PIPE SIZES 3"-2"12" AS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 1.2 GPM @ 60 PSI 2"2"12"12" FLOOR DRAIN - WATTS FD-100-L FD 2"2"12"-6" SQUARE FLOOR DRAIN, NICKEL BRONZE HEAVY DUTY GRATE AND REMOVABLE SEDIMENT BUCKET. INSTALL TRAP PRIMER KITCHEN SINKKS AS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 1.8 GPM @ 60 PSI 2"2"12" FLOOR SINK - ZURN Z1901FS 2"2"12"-12" SQUARE FLOOR SINK, ACID RESISTANCE COAT, CAST IRON BODY MATERIAL. LIGHT DUTY & HEAL PROOF GRATE. INSTALL TRAP PRIMER. TRAP PRIMER PPP PR01-ULP500TP 12"-PPP PR01-ULP500 TRAP PRIMER, LOCATE UNDER THE SINK EXPOSED OR WITHIN AN ACCESS PANEL. LEAD FREE FLOW ACTIVATION.-- SERVICE SINK/MOB SINKMS 12"AS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 2.2 GPM @ 60 PSI 2"2"12" NOTES: *NOTHING WITHIN THE SPEC'S ALLOW TO INSTALL ANY ITEM WITH DISCREPANCIES WITH LOCAL CODES AND AMENDMENTS. CONTRACTOR SHALL INFORM EOR FOR ANY POTENTIAL DISCREPANCY PRIOR ORDERING ANY FIXTURE. CONTRACTOR CAN SUBSTITUTE FIXTURES WITH ANY APPROVED EQUAL. OBTAIN OWNERSHIP APPROVAL PRIOR SUBMITTING TO EOR FOR REVIEW. *ALL INSTALLED FIXTURES AND EQUIPMENTS SHALL BE LISTED AND TESTED PER ONE OF THE APPROVED LISTING AGENCY TO THE AHJ. URINAL - ADAUR AS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 0.125 GPM @ 60 PSI. FV 2"2"1" - 12" HAND SINK - ADAHS AS SPECIFIED PER DEVELOPER/ARCHITECT. MAXIMUM FAUCET FLOW 1.2 GPM @ 60 PSI 2"2"12"12" P-02 PLUMBING FLOOR PLAN - WATER AND GAS SYMBOL SERVICE LOCATION MANUFACTURER & MODEL CAPACITY (LBS) OPER. WEIGHT DESCRIPTIONWIDTHLENGTHHEIGHT HYDROMECHANICAL GREASE TRAP CALC'S GI-1 SERVING 3 COMP (18"X18"X12"X3) = (11,664 INCH3) (4) PREP SINK (18"X18"X12") =15,552 INCH3 (3,888 INCH3 EACH) MOB SINK (21"X25"X10") =(5,250 INCH3) (9) FLOOR DRAINS @ 2 GPM): TOTAL SINK CAPACITY IN INCH3 = 32,466 INCH3 X 80% FILL CAPACITY= 25,972 INCH3/231=112 GALLONS/2 MIN=56 GPM + 18GPM FOR (9) FD = 74 GPM. PROVIDED: SCHIER GB-50. FLOW CAPACITY 75 GPM FLOW CONTROL DEVICE IS BUILT IN WITHIN THE UNIT. PER CPC 1014.2.1; THE TOTAL CAPACITY IN GALLONS OF FIXTURES DISCHARGING INTO THE HYDRO-MECHANICAL GREASE INTERCEPTOR SHALL NOT EXCEED 2.5TIMES THE CERTIFIED GPM FLOW RATE OF THE INTERCEPTOR. P-03 PLUMBING FLOOR PLAN - SEWER AND VENT PLUMBING ROOF PLANP-04 TOTAL GREASE WASTE DEMAND TOTAL SANITARY SEWER DEMAND FILTERED WATERFW PLUMBING SITE PLAN P-01 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 9/19/2025 1ST PLAN CHECK SCALE:1 PLUMBING SITE PLAN 3/32"=1'-0"SCALE:2 GREASE TRAP SPEC'S NTS WH A B C D POP-UP 13 OFFICE/STORAGE 12 RETAIL 9 ENTRY LOBBY 1 SEATING 2 WAITING 3 SERVICE COUNTER 5 KITCHEN 6 WALK-IN FRIDGE 8 SUSHI PREP. AREA 7 GRAM BAR 4 TOILET 11 TOILET 10 WAITING 3 1 32 P-02 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 9/19/2025 1ST PLAN CHECK SCALE:1 PLUMBING FLOOR PLAN - WATER AND GAS 1/4"=1'-0" PLUMBING FLOOR PLAN- WATER AND GAS NOTES: -REFER TO KITCHEN PLANS SHEET EQ101 FOR THE FULL SCHEDULE. -SCHEDULE SHOWN FOR REFERENCE ONLY. MODEL NUMBER AND MANUFACTURER TO BE VERIFIED WITH ARCH. PLANS. -FOR PLUMBING ROUGH IN CONNECTION TO EQUIPMENTS DETAILS REFER TO ARCH. PLANS SHEET EQ101. PLUMBING KEY NOTES:  &W +W  66 9EN7 72 NEW /$9$72R<  &W  66  9EN7 72 NEW W$7ER &/26E7  &W  66 9EN7 72 NEW 8RIN$/  &W /INE 83 72 7+E R22) $N' 72 $ NEW W$7ER ME7ER &22R'IN$7E W$7ER ME7ER 2N 6I7E 32IN7 2) &2NNE&7I2N 72 E;I67ING 6$NI7$R< 6EWER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+  66  9EN7 72 NEW )/22R 'R$IN)/22R 6IN. &2NNE&7 )/2W $&7I9$72R 7R$3 3RIMER 72 )'  GW  9EN7 72 NEW )/22R 'R$IN)/22R 6IN. &2NNE&7 )/2W $&7I9$72R 7R$3 3RIMER 72 )'  W$7ER )I/7ER &2NNE&7  &W /INE IN67$// %)3  &W +W  66 9EN7 72 NEW +$N' 6IN. N )22' 3RE3 6IN. &2NNE&7  &W +W $N'  66 72 )/22R 6IN. 7+R28G+  $IR G$3 N I&E M$&+INE &2NNE&7  )I/7ERE' W$7ER  66 72 )/22R 6IN. 7+R28G+  $IR G$3 IN67$// %)3 N E63RE662 M$&+INE &2NNE&7  )I/7ERE' W$7ER IN67$// %)3 N W$7ER %2I/ER &2NNE&7  )I/7ERE' W$7ER IN67$// %)3 N RIN6ER &2NNE&7  )I/7ERE' W$7ER $N'  66 72 )6 7+R28G+ $IR G$3 IN67$// %)3  &W +W  GW 9EN7 72 6ER9E  &2M3 6IN. 327 6IN.  &2M3 6IN. 6+$// %E &2NNE&7E' 3ER &3&  W+ERE )/22R 'R$IN 6+$// %E IN67$//E' $'-$&EN7 72 7+E )I;78RE $N' 6+$// %E &2NNE&7E' 2N 7+E 6EWER 6I'E 2) 7+E 6IN. N2 27+ER 'R$IN$GE /INE 6+$// %E &2NNE&7E' %E7WEEN 7+E 6IN. $N' 7+E )'  &W +W  GW  9EN7 72 NEW M2% 6IN. N G$6 62/EN2I' 9$/9E 72 %E &2NNE&7E' 72 7+E +22' )IRE 6833RE66I2N 6<67EM 3R29I'E 9‘ &2NNE&7I2N $/2NG WI7+ 6IGN$/ /INE IN67$// $&&E66 3$NE/ G$6 672R$GE 7$N. +27 W$7ER +E$7ER WI7+ 'R$IN 3$N &2NNE&7  &W+W  +WR WI7+ %$/$N&ING 9$/9E &IR&8/$7ING 38M3 GR8N')26 &2M)2R7  $ 3M %/& WI7+ $Q8$67$7 &2N7R2//ER 6E7 $7  ƒ) 6E7 +WR #  G3M /IMI7 +W 7EM3 $7 N2 M2RE 7+$N ƒ) IN 672R$GE ƒ) $)7ER 7+E MI;ING 9$/9E &2NNE&7  G$6 /INE  IN67$// &2N'EN6$7E NE87R$/I=ER  )/8E 9EN7 $N' &2M%867I2N $IR 9EN7 &2NNE&7E' 72 $ &2N&EN7RI& 9EN7 7+R8 7+E R22) IN67$// W$7ER +E$7ER 2N W$7ER +E$7ER 67$N' $33R2;IM$7E /2&$7I2N 2) ME&+$NI&$/ EQ8I3MEN76 2N R22) &2NNE&7  3RIM$R< &2N'EN6$7E 3&' /INE 72 7+E 7$I/ 3IE&E 2) /$9$72R< 2R 7+R8  $IR G$3 72 )6 3R29I'E 29ER )/2W &87 2)) 6WI7&+ IN /IE8 2) 6E&2N'$R< &2N'EN6$7E 6<67EM IN67$// &2N'EN6$7E 38M3 )2R 7+E /2NG R8N $N' $6 NEE'E' 72 R$I6E 7+E &2N'EN6$7E /INE )2R &22R'IN$7I2N WI7+ &EI/ING &2M32NEN76 G$6 R$NGE GR$  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 )R<ER G)R  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 GRI''/E GR'  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 RI&E &22.ER GR&  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ 32IN7 2) &2NNE&7I2N 72 E;I67ING 6$NI7$R< 6EWER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+ 32IN7 2) &2NNE&7I2N 72 E;I67ING G$6 /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+ 32IN7 2) &2NNE&7I2N 72 E;I67ING &2/' W$7ER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N   &W  66 9EN7 72 NEW 'RIN.ING )28N7$IN )/22R 6IN. &2NNE&7  66 $N'  9EN7 )6 6ER9ING &2N'EN6$7E 6<67EM  IN'IRE&7 W$67E 72 )/22R 6IN.  )I/7ERE' W$7ER 72 6ER9ER )REE=ER I&E &RE$M M$&+INE   &2/' W$7ER 72 W$7ER )I/7ER %< 3/8M%ING &2N7R$&72R &2N68/7 2WNER 6+I3 )2R )I/7ER 7<3E PLUMBING GENERAL NOTES: ITEM NO DESCRIPTION CW HW INDIRECT SS SS & V REFRIGERATOR JAPAN MART KITCHEN EQUIPMENTS - PLUMBING ROUGH IN SIZES N/A FW N/AN/A GAS GRIDDLE N/AN/A N/AN/AN/A N/AN/AN/A RICE COOKER N/A N/AN/AN/A 1" N/A GAS RANGE N/AN/A 3 COMP. SINK & FAUCET 2"N/A12"N/A12" MOP SINK & FAUCET 3"&2"N/A12"N/A12" PREP. SINK N/A N/A2" HAND SINK N/A 2"N/A ICE MAKER 1"N/AN/A N/A 12" ESPRESSO COFFEE MACHINE GAS FRYER N/A N/A N/A 12"N/A 1"N/A GAS 1" SELF CONTAINED REFRIGERATOR N/A N/A N/A N/A N/A 34" N/AN/A N/A 114" N/AN/AN/A 114" N/A N/A 12"12"N/A 12"12"N/A N/A N/A RINSER N/A 12"N/A 1"N/A N/A WATER BOILER N/A 12"N/A 2"N/A N/A N/A N/A2"12"12"N/ABAR. SINK SERVE FREEZER N/A 12"N/A 1"N/A N/A &2N7R$&72R 6+$// 9ERI)< E;I67ING 87I/I7< /INE6 3RI2R $N< %I' &2N7R$&72R 6+$// IN&/8'E IN +I6 %I' 7+E &267 2) 7REN&+ING E;&$9$7I2N %E''ING /2&$7ING 87I/I7< /INE6 8N'ERGR28N' $N' 'EM2/I6+ING E;I67ING 3/8M%ING )I;78RE6 I) $N< R8N 66 /INE6 $7 $ 6/23E 2)   I) N27 3266I%/E N27I)< $R&+E2R &2N7R$&72R 72 &22R'IN$7E WI7+ 2WNER RE3 G& )2R $N< 6ER9I&E IN7ERR837I2N $N' 6+$// MINIMI=E '2WN7IME &2N7R$&72R 6+$// &/E$N 6I7E E9ER<'$< $N' 'I6&$R' 7+E 'E%RI6 IN $33R23RI$7E M$NNER 2876I'E 7+E 6I7E $// +W +WR 3I3E6 6+$// %E IN68/$7E' 3ER  &$/I)2RNI$ ENERG< &2'E 7  &2N7R$&72R 6+$// 3R29I'E NEW )I;78RE6 6833/< 67236 W+$ $N' $N< 3/8M%ING )I;78RE $&&E662R<  E &2N'EN6$7E /INE 6+$// %E 3R27E&7E' IN 3/$&E RE3$IR $6 NEE'E' $N' .EE3 $6 +IG+ $6 3266I%/E #  6/23E &22R'IN$7E 2N 6I7E $N' E;7EN' 7+E E /INE 72 7+E NEW /$9 7ERMIN$7E 72 7+E 7$I/ 3IE&E 2) /$9$72R< &2N7R$&72R 6+$// &$3 $N< E 3/8M%ING 3I3E6 IN )/22R6 W$//6 $N' &EI/ING 7+$7 6ER9E E 3/8M%ING )I;78RE6 %EING REM29E'RE/2&$7E' &2N7R$&72R 6+$// W$/. 7+E 6I7E 3RI2R %I''ING 7+E -2% $N' 6+$// IN&/8'E IN %I' 7+E &267 2) E;7EN'ING M2'I)<ING $N' 83GR$'ING 3/8M%ING /INE6 72 6ER9E 7+E NEW /$<287 $N< 3/8M%ING 3I3E /$RGER 7+$N W+$7 6+2WN 2N 3/$N6 6+$// %E $&&E37$%/E I) 6M$//ER &2N7R$&72R 6+$// RE3/$&E 72 M$7&+ 6I=E6 IN'I&$7E' 2N 3/$N6 &2N7R$&72R 6+$// &22R'IN$7E WI7+ ME&+$NI&$/ &2N7R$&72R 72 RE/2&$7E $N< 3/8M%ING 9EN76 WI7+IN  2) 2876I'E $IR IN7$.E6 IN67$// &/E$N 2876 E9ER<  2R &+$NGE 2) 'IRE&7I2N $// )I;78RE 6+$// +$9E $ W$// &/E$N 287 WI7+IN 7+E W$// %E+IN' I7 IN'IRE&7 W$67E /INE M867 %E &2NNE&7E' 72 7+E 'R$IN$GE 6<67EM %< $N $IR G$3 7+E W$67E 3I3E6 6+$// N27 &2M%INE WI7+ 27+ER IN'IRE&7 W$67E 3EI3E6 WH A B C D POP-UP 13 OFFICE/STORAGE 12 RETAIL 9 ENTRY LOBBY 1 SEATING 2 WAITING 3 SERVICE COUNTER 5 KITCHEN 6 WALK-IN FRIDGE 8 SUSHI PREP. AREA 7 GRAM BAR 4 TOILET 11 TOILET 10 4' - 5 " 4'-8 1/2" WAITING 3 4' - 8 1 / 2 " 3'-7" 14 ' - 0 " 4'-0"2'-8" 4'-0"4'-0" 5' - 0 " 7' - 7 1 / 2 " 1 32 NOTES: -REFER TO KITCHEN PLANS SHEET EQ101 FOR THE FULL SCHEDULE. -SCHEDULE SHOWN FOR REFERENCE ONLY. MODEL NUMBER AND MANUFACTURER TO BE VERIFIED WITH ARCH. PLANS. -FOR PLUMBING ROUGH IN CONNECTION TO EQUIPMENTS DETAILS REFER TO ARCH. PLANS SHEET EQ101. PLUMBING GENERAL NOTES: &2N7R$&72R 6+$// 9ERI)< E;I67ING 87I/I7< /INE6 3RI2R $N< %I' &2N7R$&72R 6+$// IN&/8'E IN +I6 %I' 7+E &267 2) 7REN&+ING E;&$9$7I2N %E''ING /2&$7ING 87I/I7< /INE6 8N'ERGR28N' $N' 'EM2/I6+ING E;I67ING 3/8M%ING )I;78RE6 I) $N< R8N 66 /INE6 $7 $ 6/23E 2)   I) N27 3266I%/E N27I)< $R&+E2R &2N7R$&72R 72 &22R'IN$7E WI7+ 2WNER RE3 G& )2R $N< 6ER9I&E IN7ERR837I2N $N' 6+$// MINIMI=E '2WN7IME &2N7R$&72R 6+$// &/E$N 6I7E E9ER<'$< $N' 'I6&$R' 7+E 'E%RI6 IN $33R23RI$7E M$NNER 2876I'E 7+E 6I7E $// +W +WR 3I3E6 6+$// %E IN68/$7E' 3ER  &$/I)2RNI$ ENERG< &2'E 7  &2N7R$&72R 6+$// 3R29I'E NEW )I;78RE6 6833/< 67236 W+$ $N' $N< 3/8M%ING )I;78RE $&&E662R<  E &2N'EN6$7E /INE 6+$// %E 3R27E&7E' IN 3/$&E RE3$IR $6 NEE'E' $N' .EE3 $6 +IG+ $6 3266I%/E #  6/23E &22R'IN$7E 2N 6I7E $N' E;7EN' 7+E E /INE 72 7+E NEW /$9 7ERMIN$7E 72 7+E 7$I/ 3IE&E 2) /$9$72R< &2N7R$&72R 6+$// &$3 $N< E 3/8M%ING 3I3E6 IN )/22R6 W$//6 $N' &EI/ING 7+$7 6ER9E E 3/8M%ING )I;78RE6 %EING REM29E'RE/2&$7E' &2N7R$&72R 6+$// W$/. 7+E 6I7E 3RI2R %I''ING 7+E -2% $N' 6+$// IN&/8'E IN %I' 7+E &267 2) E;7EN'ING M2'I)<ING $N' 83GR$'ING 3/8M%ING /INE6 72 6ER9E 7+E NEW /$<287 $N< 3/8M%ING 3I3E /$RGER 7+$N W+$7 6+2WN 2N 3/$N6 6+$// %E $&&E37$%/E I) 6M$//ER &2N7R$&72R 6+$// RE3/$&E 72 M$7&+ 6I=E6 IN'I&$7E' 2N 3/$N6 &2N7R$&72R 6+$// &22R'IN$7E WI7+ ME&+$NI&$/ &2N7R$&72R 72 RE/2&$7E $N< 3/8M%ING 9EN76 WI7+IN  2) 2876I'E $IR IN7$.E6 IN67$// &/E$N 2876 E9ER<  2R &+$NGE 2) 'IRE&7I2N $// )I;78RE 6+$// +$9E $ W$// &/E$N 287 WI7+IN 7+E W$// %E+IN' I7 IN'IRE&7 W$67E /INE M867 %E &2NNE&7E' 72 7+E 'R$IN$GE 6<67EM %< $N $IR G$3 7+E W$67E 3I3E6 6+$// N27 &2M%INE WI7+ 27+ER IN'IRE&7 W$67E 3EI3E6 SCALE:1 PLUMBING FLOOR PLAN - SANITARY SEWER AND VENT 1/4"=1'-0" PLUMBING FLOOR PLAN - SANITARY SEWER AND VENT P-03 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 9/19/2025 1ST PLAN CHECK ITEM NO DESCRIPTION CW HW INDIRECT SS SS & V REFRIGERATOR JAPAN MART KITCHEN EQUIPMENTS - PLUMBING ROUGH IN SIZES N/A FW N/AN/A GAS GRIDDLE N/AN/A N/AN/AN/A N/AN/AN/A RICE COOKER N/A N/AN/AN/A 1" N/A GAS RANGE N/AN/A 3 COMP. SINK & FAUCET 2"N/A12"N/A12" MOP SINK & FAUCET 3"&2"N/A12"N/A12" PREP. SINK N/A N/A2" HAND SINK N/A 2"N/A ICE MAKER 1"N/AN/A N/A 12" ESPRESSO COFFEE MACHINE GAS FRYER N/A N/A N/A 12"N/A 1"N/A GAS 1" SELF CONTAINED REFRIGERATOR N/A N/A N/A N/A N/A 3 4" N/AN/A N/A 114" N/AN/AN/A 114" N/A N/A 12"12"N/A 12"12"N/A N/A N/A RINSER N/A 12"N/A 1"N/A N/A WATER BOILER N/A 12"N/A 2"N/A N/A N/A N/A2"12"12"N/ABAR. SINK SERVE FREEZER N/A 12"N/A 1'N/A N/A PLUMBING KEY NOTES:  &W +W  66 9EN7 72 NEW /$9$72R<  &W  66  9EN7 72 NEW W$7ER &/26E7  &W  66 9EN7 72 NEW 8RIN$/  &W /INE 83 72 7+E R22) $N' 72 $ NEW W$7ER ME7ER &22R'IN$7E W$7ER ME7ER 2N 6I7E 32IN7 2) &2NNE&7I2N 72 E;I67ING 6$NI7$R< 6EWER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+  66  9EN7 72 NEW )/22R 'R$IN)/22R 6IN. &2NNE&7 )/2W $&7I9$72R 7R$3 3RIMER 72 )'  GW  9EN7 72 NEW )/22R 'R$IN)/22R 6IN. &2NNE&7 )/2W $&7I9$72R 7R$3 3RIMER 72 )'  W$7ER )I/7ER &2NNE&7  &W /INE IN67$// %)3  &W +W  66 9EN7 72 NEW +$N' 6IN. N )22' 3RE3 6IN. &2NNE&7  &W +W $N'  66 72 )/22R 6IN. 7+R28G+  $IR G$3 N I&E M$&+INE &2NNE&7  )I/7ERE' W$7ER  66 72 )/22R 6IN. 7+R28G+  $IR G$3 IN67$// %)3 N E63RE662 M$&+INE &2NNE&7  )I/7ERE' W$7ER IN67$// %)3 N W$7ER %2I/ER &2NNE&7  )I/7ERE' W$7ER IN67$// %)3 N RIN6ER &2NNE&7  )I/7ERE' W$7ER $N'  66 72 )6 7+R28G+ $IR G$3 IN67$// %)3  &W +W  GW 9EN7 72 6ER9E  &2M3 6IN. 327 6IN.  &2M3 6IN. 6+$// %E &2NNE&7E' 3ER &3&  W+ERE )/22R 'R$IN 6+$// %E IN67$//E' $'-$&EN7 72 7+E )I;78RE $N' 6+$// %E &2NNE&7E' 2N 7+E 6EWER 6I'E 2) 7+E 6IN. N2 27+ER 'R$IN$GE /INE 6+$// %E &2NNE&7E' %E7WEEN 7+E 6IN. $N' 7+E )'  &W +W  GW  9EN7 72 NEW M2% 6IN. N G$6 62/EN2I' 9$/9E 72 %E &2NNE&7E' 72 7+E +22' )IRE 6833RE66I2N 6<67EM 3R29I'E 9‘ &2NNE&7I2N $/2NG WI7+ 6IGN$/ /INE IN67$// $&&E66 3$NE/ G$6 672R$GE 7$N. +27 W$7ER +E$7ER WI7+ 'R$IN 3$N &2NNE&7  &W+W  +WR WI7+ %$/$N&ING 9$/9E &IR&8/$7ING 38M3 GR8N')26 &2M)2R7  $ 3M %/& WI7+ $Q8$67$7 &2N7R2//ER 6E7 $7  ƒ) 6E7 +WR #  G3M /IMI7 +W 7EM3 $7 N2 M2RE 7+$N ƒ) IN 672R$GE ƒ) $)7ER 7+E MI;ING 9$/9E &2NNE&7  G$6 /INE  IN67$// &2N'EN6$7E NE87R$/I=ER  )/8E 9EN7 $N' &2M%867I2N $IR 9EN7 &2NNE&7E' 72 $ &2N&EN7RI& 9EN7 7+R8 7+E R22) IN67$// W$7ER +E$7ER 2N W$7ER +E$7ER 67$N' $33R2;IM$7E /2&$7I2N 2) ME&+$NI&$/ EQ8I3MEN76 2N R22) &2NNE&7  3RIM$R< &2N'EN6$7E 3&' /INE 72 7+E 7$I/ 3IE&E 2) /$9$72R< 2R 7+R8  $IR G$3 72 )6 3R29I'E 29ER )/2W &87 2)) 6WI7&+ IN /IE8 2) 6E&2N'$R< &2N'EN6$7E 6<67EM IN67$// &2N'EN6$7E 38M3 )2R 7+E /2NG R8N $N' $6 NEE'E' 72 R$I6E 7+E &2N'EN6$7E /INE )2R &22R'IN$7I2N WI7+ &EI/ING &2M32NEN76 G$6 R$NGE GR$  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 )R<ER G)R  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 GRI''/E GR'  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 RI&E &22.ER GR&  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ 32IN7 2) &2NNE&7I2N 72 E;I67ING 6$NI7$R< 6EWER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+ 32IN7 2) &2NNE&7I2N 72 E;I67ING G$6 /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+ 32IN7 2) &2NNE&7I2N 72 E;I67ING &2/' W$7ER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N   &W  66 9EN7 72 NEW 'RIN.ING )28N7$IN )/22R 6IN. &2NNE&7  66 $N'  9EN7 )6 6ER9ING &2N'EN6$7E 6<67EM  IN'IRE&7 W$67E 72 )/22R 6IN.  )I/7ERE' W$7ER 72 6ER9ER )REE=ER I&E &RE$M M$&+INE   &2/' W$7ER 72 W$7ER )I/7ER %< 3/8M%ING &2N7R$&72R &2N68/7 2WNER 6+I3 )2R )I/7ER 7<3E 1 3 A B C D 2 SCALE:1 PLUMBING ROOF PLAN 1/4"=1'-0" PLUMBING ROOF PLAN P-04 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 9/19/2025 1ST PLAN CHECK PLUMBING GENERAL NOTES: NOTES: -REFER TO KITCHEN PLANS SHEET EQ101 FOR THE FULL SCHEDULE. -SCHEDULE SHOWN FOR REFERENCE ONLY. MODEL NUMBER AND MANUFACTURER TO BE VERIFIED WITH ARCH. PLANS. -FOR PLUMBING ROUGH IN CONNECTION TO EQUIPMENTS DETAILS REFER TO ARCH. PLANS SHEET EQ101. ITEM NO DESCRIPTION CW HW INDIRECT SS SS & V REFRIGERATOR JAPAN MART KITCHEN EQUIPMENTS - PLUMBING ROUGH IN SIZES N/A FW N/AN/A GAS GRIDDLE N/AN/A N/AN/AN/A N/AN/AN/A RICE COOKER N/A N/AN/AN/A 1" N/A GAS RANGE N/AN/A 3 COMP. SINK & FAUCET 2"N/A12"N/A12" MOP SINK & FAUCET 3"&2"N/A12"N/A12" PREP. SINK N/A N/A2" HAND SINK N/A 2"N/A ICE MAKER 1"N/AN/A N/A 12" ESPRESSO COFFEE MACHINE GAS FRYER N/A N/A N/A 12"N/A 1"N/A GAS 1" SELF CONTAINED REFRIGERATOR N/A N/A N/A N/A N/A 34" N/AN/A N/A 114" N/AN/AN/A 114" N/A N/A 12"12"N/A 12"12"N/A N/A N/A RINSER N/A 12"N/A 1"N/A N/A WATER BOILER N/A 12"N/A 2"N/A N/A N/A N/A2"12"12"N/ABAR. SINK SERVE FREEZER N/A 12"N/A 1'N/A N/A PLUMBING KEY NOTES:  &W +W  66 9EN7 72 NEW /$9$72R<  &W  66  9EN7 72 NEW W$7ER &/26E7  &W  66 9EN7 72 NEW 8RIN$/  &W /INE 83 72 7+E R22) $N' 72 $ NEW W$7ER ME7ER &22R'IN$7E W$7ER ME7ER 2N 6I7E 32IN7 2) &2NNE&7I2N 72 E;I67ING 6$NI7$R< 6EWER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+  66  9EN7 72 NEW )/22R 'R$IN)/22R 6IN. &2NNE&7 )/2W $&7I9$72R 7R$3 3RIMER 72 )'  GW  9EN7 72 NEW )/22R 'R$IN)/22R 6IN. &2NNE&7 )/2W $&7I9$72R 7R$3 3RIMER 72 )'  W$7ER )I/7ER &2NNE&7  &W /INE IN67$// %)3  &W +W  66 9EN7 72 NEW +$N' 6IN. N )22' 3RE3 6IN. &2NNE&7  &W +W $N'  66 72 )/22R 6IN. 7+R28G+  $IR G$3 N I&E M$&+INE &2NNE&7  )I/7ERE' W$7ER  66 72 )/22R 6IN. 7+R28G+  $IR G$3 IN67$// %)3 N E63RE662 M$&+INE &2NNE&7  )I/7ERE' W$7ER IN67$// %)3 N W$7ER %2I/ER &2NNE&7  )I/7ERE' W$7ER IN67$// %)3 N RIN6ER &2NNE&7  )I/7ERE' W$7ER $N'  66 72 )6 7+R28G+ $IR G$3 IN67$// %)3  &W +W  GW 9EN7 72 6ER9E  &2M3 6IN. 327 6IN.  &2M3 6IN. 6+$// %E &2NNE&7E' 3ER &3&  W+ERE )/22R 'R$IN 6+$// %E IN67$//E' $'-$&EN7 72 7+E )I;78RE $N' 6+$// %E &2NNE&7E' 2N 7+E 6EWER 6I'E 2) 7+E 6IN. N2 27+ER 'R$IN$GE /INE 6+$// %E &2NNE&7E' %E7WEEN 7+E 6IN. $N' 7+E )'  &W +W  GW  9EN7 72 NEW M2% 6IN. N G$6 62/EN2I' 9$/9E 72 %E &2NNE&7E' 72 7+E +22' )IRE 6833RE66I2N 6<67EM 3R29I'E 9‘ &2NNE&7I2N $/2NG WI7+ 6IGN$/ /INE IN67$// $&&E66 3$NE/ G$6 672R$GE 7$N. +27 W$7ER +E$7ER WI7+ 'R$IN 3$N &2NNE&7  &W+W  +WR WI7+ %$/$N&ING 9$/9E &IR&8/$7ING 38M3 GR8N')26 &2M)2R7  $ 3M %/& WI7+ $Q8$67$7 &2N7R2//ER 6E7 $7  ƒ) 6E7 +WR #  G3M /IMI7 +W 7EM3 $7 N2 M2RE 7+$N ƒ) IN 672R$GE ƒ) $)7ER 7+E MI;ING 9$/9E &2NNE&7  G$6 /INE  IN67$// &2N'EN6$7E NE87R$/I=ER  )/8E 9EN7 $N' &2M%867I2N $IR 9EN7 &2NNE&7E' 72 $ &2N&EN7RI& 9EN7 7+R8 7+E R22) $33R2;IM$7E /2&$7I2N 2) ME&+$NI&$/ EQ8I3MEN76 2N R22) &2NNE&7  3RIM$R< &2N'EN6$7E 3&' /INE 72 7+E 7$I/ 3IE&E 2) /$9$72R< 2R 7+R8  $IR G$3 72 )6 3R29I'E 29ER )/2W &87 2)) 6WI7&+ IN /IE8 2) 6E&2N'$R< &2N'EN6$7E 6<67EM IN67$// &2N'EN6$7E 38M3 )2R 7+E /2NG R8N $N' $6 NEE'E' 72 R$I6E 7+E &2N'EN6$7E /INE )2R &22R'IN$7I2N WI7+ &EI/ING &2M32NEN76 G$6 R$NGE GR$  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 )R<ER G)R  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 GRI''/E GR'  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ G$6 RI&E &22.ER GR&  &2NNE&7  G$6 /INE WI7+ 629 M$;IM8M  %78+ 32IN7 2) &2NNE&7I2N 72 E;I67ING 6$NI7$R< 6EWER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+ 32IN7 2) &2NNE&7I2N 72 E;I67ING G$6 /INE )IE/' 9ERI)< E;I67ING /2&$7I2N 6/23E $N' 'E37+ 32IN7 2) &2NNE&7I2N 72 E;I67ING &2/' W$7ER /INE )IE/' 9ERI)< E;I67ING /2&$7I2N   &W  66 9EN7 72 NEW 'RIN.ING )28N7$IN )/22R 6IN. &2NNE&7  66 $N'  9EN7 )6 6ER9ING &2N'EN6$7E 6<67EM &2N7R$&72R 6+$// 9ERI)< E;I67ING 87I/I7< /INE6 3RI2R $N< %I' &2N7R$&72R 6+$// IN&/8'E IN +I6 %I' 7+E &267 2) 7REN&+ING E;&$9$7I2N %E''ING /2&$7ING 87I/I7< /INE6 8N'ERGR28N' $N' 'EM2/I6+ING E;I67ING 3/8M%ING )I;78RE6 I) $N< R8N 66 /INE6 $7 $ 6/23E 2)   I) N27 3266I%/E N27I)< $R&+E2R &2N7R$&72R 72 &22R'IN$7E WI7+ 2WNER RE3 G& )2R $N< 6ER9I&E IN7ERR837I2N $N' 6+$// MINIMI=E '2WN7IME &2N7R$&72R 6+$// &/E$N 6I7E E9ER<'$< $N' 'I6&$R' 7+E 'E%RI6 IN $33R23RI$7E M$NNER 2876I'E 7+E 6I7E $// +W +WR 3I3E6 6+$// %E IN68/$7E' 3ER  &$/I)2RNI$ ENERG< &2'E 7  &2N7R$&72R 6+$// 3R29I'E NEW )I;78RE6 6833/< 67236 W+$ $N' $N< 3/8M%ING )I;78RE $&&E662R<  E &2N'EN6$7E /INE 6+$// %E 3R27E&7E' IN 3/$&E RE3$IR $6 NEE'E' $N' .EE3 $6 +IG+ $6 3266I%/E #  6/23E &22R'IN$7E 2N 6I7E $N' E;7EN' 7+E E /INE 72 7+E NEW /$9 7ERMIN$7E 72 7+E 7$I/ 3IE&E 2) /$9$72R< &2N7R$&72R 6+$// &$3 $N< E 3/8M%ING 3I3E6 IN )/22R6 W$//6 $N' &EI/ING 7+$7 6ER9E E 3/8M%ING )I;78RE6 %EING REM29E'RE/2&$7E' &2N7R$&72R 6+$// W$/. 7+E 6I7E 3RI2R %I''ING 7+E -2% $N' 6+$// IN&/8'E IN %I' 7+E &267 2) E;7EN'ING M2'I)<ING $N' 83GR$'ING 3/8M%ING /INE6 72 6ER9E 7+E NEW /$<287 $N< 3/8M%ING 3I3E /$RGER 7+$N W+$7 6+2WN 2N 3/$N6 6+$// %E $&&E37$%/E I) 6M$//ER &2N7R$&72R 6+$// RE3/$&E 72 M$7&+ 6I=E6 IN'I&$7E' 2N 3/$N6 &2N7R$&72R 6+$// &22R'IN$7E WI7+ ME&+$NI&$/ &2N7R$&72R 72 RE/2&$7E $N< 3/8M%ING 9EN76 WI7+IN  2) 2876I'E $IR IN7$.E6 IN67$// &/E$N 2876 E9ER<  2R &+$NGE 2) 'IRE&7I2N $// )I;78RE 6+$// +$9E $ W$// &/E$N 287 WI7+IN 7+E W$// %E+IN' I7 IN'IRE&7 W$67E /INE M867 %E &2NNE&7E' 72 7+E 'R$IN$GE 6<67EM %< $N $IR G$3 7+E W$67E 3I3E6 6+$// N27 &2M%INE WI7+ 27+ER IN'IRE&7 W$67E 3EI3E6 ELECTRICAL LEGEND C J S 3 door f A GFCI AFCI WP OC OC d AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING MECHANICAL, ELECTRICAL, PLUMBING AND ENERGY ANALYSIS 562.413.9495 INFO@MWQENG.COM 1ST PLAN CHECK9-18-2025 E0.0 ELECTRICAL SYMBOLES AND LEGENDS Jazayeri POWER LAYOUT - ROOF SCALE: 1/4" = 1'-0" E70.10 E70.10 E70.10 POWER LAYOUT - GROUND FLOOR SCALE: 1/4" = 1'-0" AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK11-03-2025 ELECTRICAL POWER PLANS E1.0 Jazayeri OC OC OC OC OC OC LIGHTING LAYOUT SCALE: 1/4" = 1'-0" C2 9' - 0" C1 9' - 0" C1 9' - 0" C1 9' - 0" C1 9' - 0" C2 9' - 0" 23.11 26.25 LT-4 LT-5 LT-4 LT-4 LT-4 LT-5 23.06 60.02 LT-4 C1 9' - 0" C2 9' - 0" C1 9' - 0" LT-4 LT-2 LT-2 LT-2 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1LT-1LT-1 LT-1 LT-6 LT-6 C1 9' - 0" LT-4.1 LT-4 LT-4 LT-2 LT-2 OC LT-7 LT-7 LT-7 OC OC OC OC AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK11-03-2025 E2.0 LIGHTING PLAN Jazayeri LIGHTING SCHEDULE LIGHTING SHUT-OFF CONDUIT FILLING CALCULATION ONE-LINE DIAGRAM SCHEMATIC DIAGRAM AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK11-03-2025 E3.0 ONE-LINE DIAGRAM & LIGHTING SCHEDULE Jazayeri ELECTRICAL PANEL SCHEDULES AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING ME&+$NI&$/ E/E&7RI&$/ 3/8M%ING $N' ENERG< $N$/<6I6  IN)2#MWQENG&2M 1ST PLAN CHECK11-03-2025 E4.0 PANEL SCHEDULE Jazayeri 1 3 A B C D 2 C2 9' - 0" C1 9' - 0" C1 9' - 0" C1 9' - 0" C1 9' - 0" C2 9' - 0" 23.11 26.25 23.06 23.06 60.02 C1 9' - 0" C2 9' - 0" C1 9' - 0" C1 9' - 0" C1 9' - 0" C1 9' - 0" OPEN OPEN OPEN OPEN EMERGENCY PHOTOMETRIC SCALE: 1/4" = 1'-0" AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING MECHANICAL, ELECTRICAL, PLUMBING AND ENERGY ANALYSIS 562.413.9495 INFO@MWQENG.COM 1ST PLAN CHECK9-18-2025 E5.0 EMERGENCY LIGHTING PHOTOMETRIC Jazayeri AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C H I T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S Baldwin Ave, Unit B Arcadia, CA 91007 JAPAN MART 241103 REVISIONDATEDELTA PC Date: EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS Consultant: Seal: MWQ ENGINEERING MECHANICAL, ELECTRICAL, PLUMBING AND ENERGY ANALYSIS 562.413.9495 INFO@MWQENG.COM 1ST PLAN CHECK9-18-2025 E6.0 TITLE-24 Jazayeri MWQ Engineering 5 Upper Newport Plaza Dr, Suite #202 Newport Beach, California 92660 Jazayeri 09-18-25 MWQ Engineering 5 Upper Newport Plaza Dr, Suite #202 Newport Beach, California 92660 Amir Jazayeri Jazayeri 09-18-25 E23421 Amir Jazayeri WH HEALTH DEPARTMENT NOTES: 1. ALL EQUIPMENT, INCLUDING SHELVING, MUST BE SUPPORTED BY SIX (6) INCH HIGH, EASILY CLEANABLE LEGS, COMMERCIAL CASTERS, OR COMPLETELY SEALED IN POSITION ON A FOUR (4) INCH HIGH CONTINUOUSLY COVED BASE OR CONCRETE CURB. 2. THE JOCKEY BOX/ICE BIN(S) MUST HAVE A SLIDING COVER WHICH REMAINS CLOSED WHEN THE ICE IS NOT BEING ACTIVELY SCOOPED. 3. THE ONLY FOOD PREPARATION ALLOWED AT THE BAR IS THE PREPARATION OF BEVERAGES FOR IMMEDIATE SERVICE. 4. LOCKERS MUST BE INSTALLED ON SIX (6) INCH HIGH, EASILY CLEANABLE LEGS, CANTILEVERED OFF THE WALL, OR A MINIMUM FOUR (4) INCH HIGH CONTINUOUSLY COVED CURB OR PLATFORM. L-ANGLE LEGS ARE NOT ACCEPTABLE. A B C D EQ41 EQ41 EQ41 EQ41 EQ41 EQ41 EQ41EQ41EQ41EQ41 EQ49 EQ49 EQ21 EQ20 EQ23 EQ27 EQ32 EQ18 EQ32 EQ24 EQ24 EQ08 EQ27 EQ26 EQ17 EQ09 EQ15 EQ32 EQ19 EQ25 EQ24 EQ42 EQ42 EQ27 EQ35 EQ31 EQ25 EQ24 EQ24 EQ24 EQ24 EQ24 EQ32 30 " x 4 8 " 30 " x 4 8 " 30"x48"30"x48" ADJACENT TENANT AD J A C E N T T E N A N T EX T E R I O R EXTERIOR EX T E R I O R EQ06 EQ32.1 EQ52 EQ13 EQ13 POP-UP 13 OFFICE/STORAGE 12 RETAIL 9 ENTRY LOBBY 1 SEATING 2 WAITING 3 SERVICE COUNTER 5 KITCHEN 6 WALK-IN FRIDGE 8 SUSHI PREP. AREA 7 GRAM BAR 4 TOILET 11 TOILET 10 30 " x 4 8 " EQ04 EQ11 EQ11 EQ11 4' - 5 " 42 " H C O U N T E R EQ14 EQ07 EQ57 EQ57 EQ57 ELECTRICAL PANELS EQ59 EQ59 EQ59 EQ59 EQ59 EQ59 30 " x 4 8 " 30"x48" EQ55 EQ55 EQ55 EQ55 EQ30 EQ60 EQ60 EQ55 4' - 8 1/2" EQ62 EQ45 EQ46 EQ48 EQ01 EQ03 EQ02 EQ01 EQ02 EQ13 WAITING 3 EQ11 EQ11 EQ11 FIRE EXTINGUISHER E01 0706 08 05 04 03 01 02 EQ29 EQ43 EQ39 EQ33 EQ27 EQ09 EQ10 EQ63 EQ55 EQ55 EQ32 EQ32 EQ24 EQ58 EQ24.1 EQ54 EQ57 4' - 8 1 / 2 " LE D P A N E L W A L L DI S P L A Y S H E L F D I S P L A Y S H E L F EQ24 EQ50 EQ50 3' - 7" 14 ' - 0 " 4' - 0"2' - 8" 4' - 0" EQ64 EQ29 EQ47 EQ44 38 " H I G H C O U N T E R 34 " H I G H C H E C K O U T CO U N T E R 34 " H I G H C H E C K O U T CO U N T E R 34 " H I G H C O U N T E R 4' - 0" 34 " HI G H 30 " x 4 8 " 5' - 0" 7' - 7 1 / 2 " EQ32.2 EQ04 EQ04 EQ04 EQ65 EQ66 EQ32 EQ67 38 " H I G H CO U N T E R 38 " H I G H CO U N T E R 312 KITCHEN(584.33 SQ FT) + SUSHI BAR(234.39) + GRAM BAR(315.5) = 1,134.22 SQ. FT 1,134.22 X 25% = 283.56 SQ. FT (MINIMUM REQUIRED STORAGE) TOTAL STORAGE = 345 SQ.FT 96 LINEAL FT PER 100 SQAURE FT OF MINIMUM REQUIRED STORAGE 272.22 LINEAL FT OF SHELVING REQUIRED PROVIDED SHELVING = 275 LINEAL FT RENEWAL DATE RCHIT EC T DESNECIL A ALI F ORNIA FOET A T S C JOHNNY C. LU C-30396 6/30/2027 AL L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N CO N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F T H E A R C H I T E C T A N D T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D OR D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E A R C HI T E C T . Sheet Title Sheet # TAG Project Number: 411 EAST HUNTINGTON DRIVE, SUITE 308 ARCADIA, CALIFORNIA 91006 PHN: (626) 446-5300 1107 S BALDWIN AVE, UNIT B ARCADIA, CA 91007 JAPAN MART Consultant: Seal: 241103 REVISIONDATEDELTA PC Date: 11/03/2025 EMPIRE ELEPHANT USA PERMIT Date: BID Date: Client: DESIGN WORKS C:\Users\Edison Wang\Documents\JapanMart_Arcadia_R24_central_ewangTPPX8.rvt EQUIPMENT PLAN AND SCHEDULE FS101 EQUIPMENT SCHEDULE # COUNT EQUIPMENT DESCRIPTION MANUFACTURER MODEL NO. SUPPLY BY INSTALL BY Comments EQ01 2 GRIDDLE ACCUTEMP GGF1201B4850-T1 OWNER G.C. EQ02 2 EQUIPMENT STAND INTERTEK ES-P3048 OWNER G.C. EQ03 1 WORKTOP REFRIGERATOR TRUE TWT-48-HC OWNER G.C. SELF-CONTAINED EQ04 4 UNDERCOUNTER REFRIGERATOR TURBO AIR MUR-48-N OWNER G.C. <varies> EQ06 1 REFRIGERATOR TRAULSEN RHT232WUT-FHS OWNER G.C. SELF-CONTAINED EQ07 1 FAUCET REGENCY 600FW86G G.C. G.C. EQ08 1 PREP TABLE EVEREST EPBNR3 OWNER G.C. EQ09 2 RICE COOKER RINNAI RER55ASN OWNER G.C. EQ10 1 RICE WARMER ZOJIRUSHI RDS-600 OWNER G.C. EQ11 3 DEEP FRYER PITCO PITCO35C+ OWNER G.C. EQ12 1 WALK IN COOLER AIRCOOLER COOLER AND FREEZER OWNER G.C. EQ13 2 AIR CURTAIN (36") CURTRON (AIR-PRO) AP-2-75-2-SS G.C. G.C. 1600 FPM EQ14 1 AIR CURTAIN (72") CURTRON (MICROSHIELD) MCS-72 G.C. G.C. 1600 FPM EQ15 1 EQUIPMENT STAND STEELTON 522SG3024 OWNER G.C. EQ17 1 4 BURNERS GAS RANGE WITH OVEN COOK RITE ATO-4B OWNER G.C. EQ18 1 THREE COMPARTMENT SINK GSW SE18183D G.C. G.C. EQ19 1 FAUCET T&S 5PR-8W12 G.C. G.C. EQ20 1 MOP SINK ADVANCE TABCO 9-OP-20+K-116 G.C. G.C. EQ21 1 FAUCET ADVANCE TABCO K-240 G.C. G.C. EQ23 1 UTILITY SHELF ADVANCE TABCO K-246 G.C. G.C. EQ24 10 WIRE SHELVING METRO 1848BR OWNER G.C. 5-SHELVES EQ24.1 1 WIRE SHELVING METRO 1836BR OWNER G.C. 5-SHELVES EQ25 2 WIRE SHELVING METRO 1860BR OWNER G.C. 5-SHELVES EQ26 1 PREP. SINK ADVANCE TABCO 93-1-24-18 G.C. G.C. EQ27 4 HAND SINK AERO MANUFACTURING HSDE G.C. G.C. EQ29 1 EXHAUST HOOD (9 FEET) CAPTIVEAIRE REFER TO MECHANICAL DRAWING G.C. G.C. EQ30 1 EXHAUST HOOD (13 FEET) CAPTIVEAIRE REFER TO MECHANICAL DRAWING G.C. G.C. EQ31 1 FAUCET ADVANCE TABCO K-101 G.C. G.C. EQ32 6 WORK TABLE ADVANCE TABCO TT-304-X 48" OWNER G.C. EQ32.1 1 WORK TABLE ADVANCE TABCO TT-304-X60" OWNER G.C. EQ32.2 1 WORK TABLE ADVANCE TABCO TTS-180X30" OWNER G.C. EQ33 1 UNDERCOUNTER REFRIGERATOR ATOSA MGF8406GR OWNER G.C. EQ35 1 ONE COMPARTMENT SINK AERO MANUFACTURING MF1-1818 G.C. G.C. EQ39 1 ICE MAKER, UNDERCOUNTER MANITOWOC ICE UYF0140A OWNER G.C. EQ41 10 GONDOLA ISLAND LOZIER WED44825LBS OWNER G.C. EQ42 2 DIGITAL KIOSK TBD TBD OWNER G.C. EQ43 1 SOFT SERVE FREEZER TAYLOR C723 OWNER G.C. EQ44 1 BLENDER VITAMIX COMMERCIAL THE QUIET ONE OWNER OWNER EQ45 1 ESPRESSO COFFEE MACHINE LA MARZOCCO LINEA CLASSIC S (2 GROUPS) OWNER G.C. EQ46 1 BAR & CAFE RINSER ESPRESSO PARTS EPPR724 G.C. G.C. EQ47 1 WATER BOILERS MARCO MT8 1000763 OWNER G.C. EQ48 1 COFFEE GROUNDER MAZZER MAJOR V OWNER OWNER EQ49 2 SIX TIER METAL LOCKER ASI Storage ASI 16121278 OWNER G.C. EQ50 2 STAND MIXER KITCHENAID KSM150PS OWNER OWNER EQ52 1 SANDWICH PREP REFRIGERATOR TRUE TSSU-60-16-HC OWNER G.C. SELF-CONTAINED EQ53 2 TRASH BIN TBD TBD OWNER G.C. EQ54 1 BAR SINK ELKAY BLH15C G.C. G.C. EQ55 7 COLD DISPLAY CASE 48" BLUEAIR TOAM-48-HC~NSL01 OWNER G.C. EQ57 4 POS SYSTEM TBD TBD OWNER OWNER EQ58 1 SANDWICH PREP. TABLE TURBO AIR MST-36-15-N6 OWNER G.C. EQ59 6 WIRE SHELVING METRO 2448BR OWNER G.C. EQ60 2 GONDOLA ISLAND LOZIER WED44825LBS OWNER G.C. EQ62 1 PREP. SINK ADVANCE TABCO 93-1-24-18 G.C. G.C. EQ63 1 FULL SERVICE REFRIGERATED CASE W/ GLASS HOWARD-MCRAY SC-CMS34N-12-LED OWNER G.C. SELF-CONTAINED EQ64 1 KNOCK BOX BARISTA BASICS KNOCK BOX 6"X5.5"X4" OWNER OWNER EQ65 1 MAKI CUTTER SUSHI ROBOTS ASM260CE OWNER OWNER EQ66 1 ROLL SUSHI MAKING MACHINE SUZUMO SVR-BXA-ET OWNER OWNER EQ67 1 COMPACT SUSHI MACHINE SUZUMO SSN-JLX OWNER OWNER GENERAL NOTES 1/4" = 1'-0"1EQUIPMENT PLAN STORAGE CALCULATIONS FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S ST O R E F R O N T FI X E D G L A S S S T O R E F R O N T NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. NOTE: EXTERIOR DOORS SHOULD BE SELF-CLOSING AND RODENT PROOFED. FINAL INSPECTION AND APPROVAL ARE REQUIRED PRIOR TO THE START OF OPERATION. THE DEPARTMENT REQUIRES AT LEAST THREE WORKING DAYS NOTICE PRIOR TO THE DATE OF THE FINAL INSPECTION. BEFORE STARTING CONSTRUCTION, A BUILDING PERMIT MUST BE OBTAINED FROM YOUR BUILDING AND SAFETY DEPARTMENT ANY CHANGES TO APPROVED PLAN MUST BE BROUGHT TO YOUR PLAN CHECKERS ATTENTION WARNING!! IT IS MISDEMEANOR VIOLATION TO BEGIN OPERATION WITHOUT A FINAL INSPECTION AND A VALID HEALTH PERMIT/LICENSE. YOUR HEALTH PERMIT/LICENSE WILL BE ISSUED BY LA COUNTY HEALTH OFFICER AT THE JOB SITE. REMODELED AREAS OF EXISTING FOOD ESTABLISHMENT/FACILITY MUST ALSO HAVE A FINAL INSPECTION. COUNTY OF LOS ANGELES - DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALTH - PLAN CHECK PROGRAM TH0E PROPOSED CONSTRUCTION/EQUIPMENT INSTALLATION IS APPROVED: RESTAURANT - SR0423090 TYPE OF ESTABLISHMENT/SERVICE REQUEST# THE APPROVAL DOES NOT AUTHORIZE THE VIOLATION OF ANY LAW, ORDINANCE OR REGULATION. APPROVED: 11/21/2025 BY: VICKI NGO DATE PLAN CHECK INSPECTOR (SEE PLAN APPROVAL SHEET, ATTACHED) LOS ANGELES COUNTY DEPARTMENT OF PUBLIC HEALTH PLAN CHECK PROGRAM 5050 COMMERCE DR BALDWIN PARK, CA 91706 (626)430-5560 DIRECT CONNECTED INDIRECT CONNECTED INDIRECT CONNECTED INDIRECT CONNECTED INDIRECT CONNECTED INDIRECT CONNECTED INDIRECT CONNECTED