Loading...
HomeMy WebLinkAbout123 W Huntington Dr - 2025 - Hilton Japanese RestaurantARCHITECT: AXIS/GFA ARCHITECTURE + DESIGN 700 S FLOWER STREET, SUITE 520 LOS ANGELES, CA 90017 PHONE: 310-209-7520 CONTACT: KEVIN SUND EMAIL: ksund@axisarchitecture.com OWNER: OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE, ARCADIA, CA 91006 PHONE: 626-821-8777 CONTACT: MIKE SOO EMAIL: msoo@asiaspec.com INTERIOR DESIGN: BUNNYFISH STUDIO 208 S. MARYLAND PKWY, SUITE A LAS VEGAS, NEVADA 89101 PHONE: 702.241.9751 CONTACT: DENISE DEIGNAN EMAIL: Denise@studiobunnyfish.com LIGHTING DESIGN: LIGHTING DESIGN STUDIO, LLC 215 PIER AVENUE, SUITE B HERMOSA BEACH, CA 90254 PHONE: 310.293.3384 CONTACT: CHRIS BOWSHER EMAIL: cbowsher@ld-studio.com MECHANICAL, ELECTRICAL, PLUMBING: SALAS O'BRIEN 8825 RESEARCH DR IRVINE, CA 92618 PHONE: 9495174900 CONTACT: JAMES ZWINGMAN EMAIL: james.zwingman@salasobrien.com FOOD & BEVERAGE: ANOKIA, INC. PHONE: (626) 222-0621 CONTACT: MATTHEW JENG EMAIL: mjeng@anokiainc.com LOW VOLTAGE: CONVERGENT SERVICES PHONE: (714) 743-1286 CONTACT: JERRY KELLINGER EMAIL:jerry@convergentservices.ws STRUCTURAL: MHP STRUCTURAL ENGINEERS 3900 COVER STREET, LONG BEACH, CA 90808 PHONE: 562-985-3200 CONTACT: KENNETH D. O'DELL EMAIL: kodell@mhpse.com VICINITY MAP TRUE NORTH / PROJECT NORTH N PROJECT SITE HUNTINGTON DR C O L O R A D O P L SA N R A F A E L R D . 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 PERMIT SET 11/26/2025 11 / 2 5 / 2 0 2 5 1 0 : 0 9 : 5 2 A M G0 COVER SHEET HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 JAPANESE RESTAURANT JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 PROJECT CONSISTS OF: INTERIOR CONSTRUCTION OF A NEW RESTAURANT WITH (N) KITCHEN, (N) PARTITIONS WITHIN (E) BUILDING C LEVEL 1 FUTURE RESTAURANT CORE AND SHELL SPACE. OCCUPANCY & TYPE REMAINS THE SAME. NOTE: PLUMBING CALCULATION WAS PERMITTED IN PREVIOUS PERMIT 22-2452 & 24-1515. TABLE CPC TABLE 422.1 APPLIES TO NEW BUILDINGS, ADDITIONS TO A BUILDING AND CHANGES OF OCCUPANCY OR TYPE IN AN EXISTING BUILDING RESULTING IN INCREASED OCCUPANT LOAD. DUE TO NO CHANGE OF OCCUPANCY OR TYPE, PLUMBING COUNT REMAINS THE SAME. PROJECT NAME: HILTON ARCADIA PROJECT ADDRESS:123 W HUNTINGTON DR., ARCADIA, CA 91007 LOT LEGAL DISCRIPTION: REAL PROPERTY IN THE CITY OF ARCADIA, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: PARCEL ONE: (5775-015-024,025 & 026) 125 HUNTINGTON DR. PARCEL 1 AS SHOWN UPON PARCEL MAP NO. 12826, IN THE CITY OF ARCADIA, IN THE COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, FILED IN BOOK 129 PAGE 35 OF PARCEL MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY AS SAID PARCEL MAP NO. 12826 WAS CORRECTED BY CERTIFICATE OF CORRECTION RECORDED ON NOVEMBER 28, 1980 AS DOCUMENT NO. 80-1203029 OFFICIAL RECORDS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. EXCEPT THAT PORTION OF SAID PARCEL INCLUDED WI`THIN THE LINES OF THE LAND DESCRIBED IN THE DEED TO THE CITY OF ARCADIA, RECORDED ON NOVEMBER 26, 1979 AS DOCUMENT NO. 79-1326058 OFFICIAL RECORDS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. ALSO EXCEPT THEREFROM ANY EXISTING STREET, PROPOSED STREET, OR PORTION OF ANY STREET OF PROPOSED STREET LYING OUTSIDE THE BOUNDARIES OF SAID LAND WHICH MIGHT OTHERWISE PASS WITH A CONVEYANCE OF SAID LAND AS RESERVED IN THE DEED FROM THE ARCADIA REDEVELOPMENT AGENCY A PUBLIC BODY CORPORATE AND POLITICAL RECORDED MAY 31, 1978 AS INSTRUMENT NO. 78-582148 OFFICIAL RECORDS. First American Title REAL PROPERTY IN THE CITY OF ARCADIA, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: PARCEL TWO: (5775-015-027) 161 COLORADO PLACE LOT 1 OF TRACT 62234, IN THE CITY OF ARCADIA, IN THE COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AS PER MAP FILED IN BOOK 1345 PAGES 92 AND 93 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. First American Title ZONING:C-G GENERAL COMMERCIAL WITH DOWNTOWN OVERLAY TYPE OF CONSTRUCTION: BUILDING C -TYPE IA , BUILDING D -TYPE IA PODIUM (LEVEL 1-2) AND TYPE IIIA (LEVEL 3-6) OCCUPANCY GROUP: BUILDING C BASEMENT:GROUP B, S-1 LEVEL 1: MIXED USE OCCUPANCY (NON-SEPARATED, A,B, S-2) LEVEL 2-3: GUESTROOMS GROUP R-1 ROOFTOP: MIXED USE OCCUPANCY (NON-SEPARATED) BUILDING D LEVEL 1-2: MIXED USE OCCUPANCY (NON-SEPARATED, A,B,S-1,S-2) LEVEL 3-5: GUESTROOMS GROUP R-1 FIRE DETECTION:ALARM SYSTEM WITH VOICE EVACUATION IN LOW RISE SMOKE DETECTION:SYSTEM IN LOW RISE FIRE EXTINGUISHING SYSTEM:AUTOMATIC SPRINKLER -INSTALLED PER NFPA 13 - FULLY SPRINKLERED STANDPIPE SYSTEM:CLASS 1 1. FIRE SPRINKLER SYSTEM (NFPA 13) 2. FIRE ALARM / SMOKE ALARM SYSTEM AND COMPLYING WITH 403.3 3. KITCHEN EXTINGUISHING SYSTEM 4. WALK IN COOLER GOVERNING CODES:* • 2022 CALIFORNIA BUILDING CODE • 2022 CALIFORNIA ELECTRIC CODE • 2022 CALIFORNIA ENERGY CODE • 2022 CALIFORNIA MECHANICAL CODE • 2022 CALIFORNIA PLUMBING CODE • 2022 CALIFORNIA GREEN BUILDING CODE * ALL OTHER CURRENT MUNICIPAL AND LOCAL ORDINANCES AND REGULATIONS 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 5 6 : 3 1 A M G1 PROJECT INFORMATION (TI) HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT PROJECT SCOPE OCCUPANCY SEPARATION OCCUPANCY A R S-2, U B, M, S-1 A - 1 - 1 R 1 - 1 1 S-2, U - 1 - 1 B, M, S-1 1 1 1 - FIRE SEPARATION REQUIREMENTS (HOURS) FOR FULLY SPRINKLERED BUILDING PER CBC TABLE 508.4 FIRE SEPARATION REQUIREMENTS TABLE 601 - FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) Key Name BUILDING ELEMENT TYPE I TYPE III A A 1 PRIMARY STRUCTURAL FRAME (SEE SECTION 202) 3 1 2 BEARING WALLS - EXTERIOR 3 2 3 BEARING WALLS - INTERIOR 3 1 4 NONBEARING WALLS AND PARTITIONS - EXTERIOR SEE TABLE 602 SEE TABLE 602 5 NONBEARING WALLS AND PARTITIONS - INTERIOR 0 0 6 FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (SEE SECTION 202)2 1 7 ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (SEE SECTION 202)1 1/2 1 TABLE 705.8 - FIRE SEPARATION DISTANCE (FSD) AND OPENING PROTECTION FIRE SEPARATION DISTANCE % UNPROTECTED OPENINGS ALLOWED IN SPRINKLERED BUILDING PER CBC TABLE 705.8 5' ≤ FSD < 10' 25% 10' ≤ FSD < 15' 45% 15' ≤ FSD < 20' 75% 20' ≤ FSD NO LIMIT PROJECT DATA SUMMARY - EXISTING FIRE / LIFE SAFETY REQUIREMENTS SEPARATE PERMITS CODE REFERENCE SHEET INDEX - TI SHEET NO. SHEET TITLE GENERAL (TI) G0 COVER SHEET G1 PROJECT INFORMATION (TI) G0.01 (FOR REFERENCE ONLY) PROJECT INFORMATION G2 SYMBOLS & ABBREVIATIONS (TI) G0.44 (FOR REFERENCE ONLY) BLDG. C PATH OF TRAVEL G0.51 (FOR REFERENCE ONLY) EXITING SITE PLAN G0.52 (FOR REFERENCE ONLY) BLDG. C & D EXITING - LEVEL1 G0.52A (FOR REFERENCE ONLY) BLDG. C & D EXITING - COURTYARD ANALYSIS G3.a GENERAL NOTES G3.b GENERAL NOTES G3.c GENERAL NOTES G4.a BARRIER FREE REQUIREMENTS G4.b BARRIER FREE REQUIREMENTS G4.c BARRIER FREE REQUIREMENTS G4.d BARRIER FREE REQUIREMENTS G4.e BARRIER FREE REQUIREMENTS G4.f BARRIER FREE REQUIREMENTS 17 ARCHITECTURE (TI) A1 DOOR SCHEDULES AND DOOR TYPES (TI) A1.01 (FOR REFERENCE ONLY) SITE PLAN A2 BLDG. C FLOOR PLAN - LEVEL 1 (TI) A3 BLDG.C ENL. PLAN - JAPANESE RESTAURANT (TI) A3.12 (FOR REFERENCE ONLY) ENL. PLAN - PUBLIC RESTROOM A5.01 (FOR REFERENCE ONLY) BLDG. C SECTIONS A8 WALL TYPES AND INTERIOR DETAILS A8.35 (FOR REFERENCE ONLY) SHAFT DETAILS A8.a FLOOR/WALL PENETRATION DETAILS A8.b FLOOR/WALL PENETRATION DETAILS A8.c FLOOR/WALL PENETRATION DETAILS A9 CEILING DETAILS (TI) 12 INTERIOR (TI) ID10.11 DETAILS ID10.12 DETAILS 2 STRUCTURAL (TI) S100 STRUCTURAL NOTES AND ABBREVIATIONS S200R FOR REFERENCE ONLY S600 TYPICAL STEEL STUD DETAILS S601 TYPICAL STEEL STUD SECTIONS AND DETAILS S620 TYPICAL STEEL STUD CEILING SECTIONS AND DETAILS S700R FOR REFERENCE ONLY TABLE 705.5 - FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE FIRE SEPARATIO N DISTANCE (NEW) TYPE OF CONSTRUC TION FIRE-RESISTANCE RATING( F-1, M, S-1) (HOURS) FIRE-RESTANCE RATING (A, B, E, F-2, I, R, S-2, U) (HOURS) X < 5 ALL 2 1 5 ≤ X < 10 IA, IVA 2 1 5 ≤ X < 10 OTHERS 1 1 10 ≤ X < 30 IA, IB, IVA, IVB 1 1 10 ≤ X < 30 IIB, VB 0 0 10 ≤ X < 30 OTHERS 1 1 X ≥ 30 ALL 0 0 SHEET INDEX - TI SHEET NO. SHEET TITLE 6 MECHANICAL (TI) M000 MECHANICAL SYMBOLS, ABBREVIATIONS & GENERAL NOTES M001 MECHANICAL TITLE 24 M002 MECHANICAL TITLE 24 M101 MECHANICAL BUILDING C - LEVEL 1 FLOOR PLAN - EAST M1.02 (FOR REFERENCE ONLY) MECHANICAL BUILDING C - LEVEL 1 FLOOR PLAN - EAST M102 MECHANICAL BUILDING C - LEVEL 2 FLOOR PLAN - EAST M103 MECHANICAL BUILDING C - LEVEL 3 FLOOR PLAN - EAST M104 MECHANICAL BUILDING C - ROOF LEVEL PLAN - EAST M401 MECHANICAL ENLARGED LEVEL 1 PLANS M402 MECHANICAL ENLARGED ROOF PLANS M501 MECHANICAL DETAILS M502 MECHANICAL DETAILS M601 MECHANICAL SCHEDULES - BLDG C M701 MECHANICAL AIRSIDE DIAGRAMS 14 PLUMBING (TI) P000 PLUMBING GENERAL NOTES, SYMBOLS & ABBREVIATIONS P001 PLUMBING SCHEDULES P101 PLUMBING FLOOR PLAN - SANITARY, GREASE & VENT PIPING CP1.1A (FOR REFERENCE ONLY) PLUMBING FIRST FLOOR PLAN P102 PLUMBING FLOOR PLAN - DOMESTIC WATER & NATURAL GAS PIPING P103 PLUMBING ROOF PLAN - NATURAL GAS PIPING P501 PLUMBING DETAILS P601 PLUMBING ISOMETRICS P602 PLUMBING ISOMETRICS 9 ELECTRICAL (TI) E000 ELECTRICAL SYMBOLS, ABBREVIATINS & GENERAL NOTES E001 ELECTRICAL SPECIFICATIONS E002 ELECTRICAL TITLE 24 E101 ELECTRICAL BUILDING C - LEVEL 1 POWER PLAN - EAST E401 ELECTRICAL ENLARGED PLANS EL401 ELECTRICAL LIGHTING ENLARGED PLANS EL402 ELECTRICAL LIGHTING PHOTOMETRICS EL403 ELECTRICAL LIGHTING CONTROL AND DIMMING SYSTEM PLAN E501 ELECTRICAL DETAILS E601 ELECTRICAL SCHEDULES & SINGLE LINE DIAGRAM 10 FOOD SERVICE (TI) K100 EQUIPMENT PLAN K110 EQUIPMENT SCHEDULE K120 EQUIPMENT PLAN- ELEC. OUTLETS K130 EQUIPMENT PLAN- GAS K140 EQUIPMENT PLAN- WATER SUPPLY K150 EQUIPMENT PLAN- WATER WASTE K160 INDEX PLAN K161 ELEVATIONS 8 LIGHTING (TI) SK-LT.1 LIGTHING PLAN 1 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 PROJECT CONSISTS OF: INTERIOR CONSTRUCTION OF A NEW RESTAURANT WITH (N) KITCHEN, (N) PARTITIONS WITHIN (E) BUILDING C LEVEL 1 FUTURE RESTAURANT CORE AND SHELL SPACE. OCCUPANCY & TYPE REMAINS THE SAME. NOTE: PLUMBING CALCULATION WAS PERMITTED IN PREVIOUS PERMIT 22-2452 & 24-1515. TABLE CPC TABLE 422.1 APPLIES TO NEW BUILDINGS, ADDITIONS TO A BUILDING AND CHANGES OF OCCUPANCY OR TYPE IN AN EXISTING BUILDING RESULTING IN INCREASED OCCUPANT LOAD. DUE TO NO CHANGE OF OCCUPANCY OR TYPE, PLUMBING COUNT REMAINS THE SAME. PROJECT NAME: HILTON ARCADIA PROJECT ADDRESS:123 W HUNTINGTON DR., ARCADIA, CA 91007 LOT LEGAL DISCRIPTION: REAL PROPERTY IN THE CITY OF ARCADIA, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: PARCEL ONE: (5775-015-024,025 & 026) 125 HUNTINGTON DR. PARCEL 1 AS SHOWN UPON PARCEL MAP NO. 12826, IN THE CITY OF ARCADIA, IN THE COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, FILED IN BOOK 129 PAGE 35 OF PARCEL MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY AS SAID PARCEL MAP NO. 12826 WAS CORRECTED BY CERTIFICATE OF CORRECTION RECORDED ON NOVEMBER 28, 1980 AS DOCUMENT NO. 80-1203029 OFFICIAL RECORDS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. EXCEPT THAT PORTION OF SAID PARCEL INCLUDED WI`THIN THE LINES OF THE LAND DESCRIBED IN THE DEED TO THE CITY OF ARCADIA, RECORDED ON NOVEMBER 26, 1979 AS DOCUMENT NO. 79-1326058 OFFICIAL RECORDS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. ALSO EXCEPT THEREFROM ANY EXISTING STREET, PROPOSED STREET, OR PORTION OF ANY STREET OF PROPOSED STREET LYING OUTSIDE THE BOUNDARIES OF SAID LAND WHICH MIGHT OTHERWISE PASS WITH A CONVEYANCE OF SAID LAND AS RESERVED IN THE DEED FROM THE ARCADIA REDEVELOPMENT AGENCY A PUBLIC BODY CORPORATE AND POLITICAL RECORDED MAY 31, 1978 AS INSTRUMENT NO. 78-582148 OFFICIAL RECORDS. First American Title REAL PROPERTY IN THE CITY OF ARCADIA, COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: PARCEL TWO: (5775-015-027) 161 COLORADO PLACE LOT 1 OF TRACT 62234, IN THE CITY OF ARCADIA, IN THE COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AS PER MAP FILED IN BOOK 1345 PAGES 92 AND 93 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY. First American Title ZONING:C-G GENERAL COMMERCIAL WITH DOWNTOWN OVERLAY TYPE OF CONSTRUCTION: BUILDING C -TYPE IA , BUILDING D -TYPE IA PODIUM (LEVEL 1-2) AND TYPE IIIA (LEVEL 3-6) OCCUPANCY GROUP: BUILDING C BASEMENT:GROUP B, S-1 LEVEL 1: MIXED USE OCCUPANCY (NON-SEPARATED, A,B, S-2) LEVEL 2-3: GUESTROOMS GROUP R-1 ROOFTOP: MIXED USE OCCUPANCY (NON-SEPARATED) BUILDING D LEVEL 1-2: MIXED USE OCCUPANCY (NON-SEPARATED, A,B,S-1,S-2) LEVEL 3-5: GUESTROOMS GROUP R-1 GOVERNING CODES:* • 2019 CALIFORNIA BUILDING CODE • 2019 CALIFORNIA ELECTRIC CODE • 2019 CALIFORNIA ENERGY CODE • 2019 CALIFORNIA MECHANICAL CODE • 2019 CALIFORNIA PLUMBING CODE • 2019 CALIFONIA GREEN BUILDING CODE * ALL OTHER CURRENT MUNICIPAL AND LOCAL ORDINANCES AND REGULATIONS THE FOLLOWING ARE DESIGN/BUILD ENGINEERING SYSTEMS AND WILL BE DEFERRED PERMIT SUBMITTALS TO THE AUTHORITY HAVING JURISDICTION: 1. STEEL STAIRS, STEEL HANDRAILS, AND GUARDRAILS 2. GLASS GUARDRAILS & WINDSCREENS 3. EXTERIOR WINDOW WALL AND STOREFRONT SYSTEMS 4. ELEVATORS AND EQUIPMENT ANCHORAGE, VIBRATION ISOLATION, AND SEISMIC RESTRAINT 5. CABLE GUARDRAILS 6. GAS SENSOR MONITORING 7. NON-STRUCTURAL METAL STUD FRAMING 8. COLD FORMED METAL STUD FRAMING SYSTEM (EXTERIOR) 9. EXTERIOR, INTERIOR, WAYFINDING & CODE REQUIRED SIGNAGE. (EXCEPT EMERGENCY EXIT SIGNS) 10. PT STRANDS AND ANCHORAGE 11. EXTERIOR FINISH SYSTEM ATTACHMENT 12. EMERGENCY GENERATOR ANCHORAGE AND AQMD APPROVAL 13. TWO-WAY COMMUNICATION SYSTEM GUESTROOMS WITH MOBILITY FEATURES: [8 REQUIRED ; 8 PROVIDED] PROPORTIONAL DISTRIBUTION OF GUESTROOMS WITH MOBILITY FEATURES PER TABLE 11B-224.2: (173) TOTAL GUESTROOMS (6) GUESTROOMS WITH TUBS (2) GUESTROOMS WITH ROLL-IN SHOWER (R.I.S.) GUESTROOMS WITH COMMUNICATION FEATURES: [14 REQUIRED ; 14 PROVIDED] PER TABLE 11B-224.4 (173) TOTAL GUESTROOMS: (14) GUESTROOMS FOR THE HEARING IMPAIRED ARE REQUIRED. (14) TOTAL GUESTROOMS PROVIDED WITH "AUDIBLE & VISIBLE" ALARM NOTIFICATION DEVICE. FOR SPECIFIC FEATURES REFER TO ELECTRICAL PLANS. REQUIRED VEHICLE PARKING PARKING REQUIRED (ZONING SEC. 9103.07.060, C, TABLES 3-5 &, 3-6) A.EXISTING BUILDING A 19,845 SQ.FT.MEDICAL OFFICE 1/200 = 99 B.EXISTING BUILDING B 19,231 SQ.FT.MEDICAL OFFICE 1/200 = 96 C.REMODELED BUILDING C 91 ROOMS GUESTROOM 1.2 = 109 3,238 SQ.FT.RESTAURANT 1/200 = 17 1,155 SQ.FT.BAR 1/100 = 12 ROOFTOP BAR 1/EVERY 6 SEATS= 21 D.BUILDING D 82 ROOMS GUESTROOM 1.2 = 98 7223 SQ.FT. BANQUET = 0 1449 SQ.FT. PRE-FUNCTION = 0 TOTAL PARKING REQUIRED = 452 ACCESSIBLE PARKING STALLS REQUIRED (CBC 11B-208.2 TABLE 11B-208.2) A.BUILDING A MEDICAL OFFICE 4 B.BUILDING B MEDICAL OFFICE 4 C/D.HOTEL & RESTAURANT + BAR +BANQUET+PRE-FUNCTION 7 TOTAL REQUIRED 15 PROVIDED (PARKING STRUCTURE)14 PROVIDED (EAST SIDE SURFACE PARKING) 3 TOTAL PROVIDED 17 1 VAN PER 6 ACCESSIBLE STALLS (CBC 11B-208.2.4) VAN ACCESSIBLE PARKING STALLS REQUIRED 3 PROVIDED (PARKING STRUCTURE) 7 PROVIDED (EAST SIDE SURFACE PARKING) 1 PROVIDED 8 PARKING PROVIDED A.WEST SIDE SURFACE PARKING 24 SPACES B.PARKING STRUCTURE BASEMENT 114 SPACES PARKING STRUCTURE 1ST FLOOR 80 SPACES PARKING STRUCTURE 2ND FLOOR 88 SPACES PARKING STRUCTURE 3RD FLOOR 105 SPACES C.EAST SIDE SURFACE PARKING 48 SPACES TOTAL PARKING PROVIDED 459 SPACES* *COMMERCIAL LOADING ZONE STALLS HAVE BEEN REMOVED FROM CALCULATION LOADING SPACES PROVIDED (10'X25') 3 TOTAL BIKE RACK A.BIKE PARKING REQUIRED PER ZONING: 5% OF 452 = 23 BIKES B.BIKE PARKING PROVIDED:= 23 BIKES (7 PROVIDED ON EAST SIDE SURFACE PARKING, 16 PROVIDED IN (E) PARKING STRUCTURE) BIKE LOCKERS A.BIKE LOCKERS REQUIRED PER ZONING: 5% OF 452 = 23 BIKE LOCKERS B.BIKE LOCKERS PROVIDED:= 23 BIKE LOCKERS (3 PROVIDED IN BLDG C, 20 PROVIDED IN (E) PARKING STRUCTURE) FUEL EFFICIENT VEHICLES A.FUEL EFFICIENT VEHICLE PARKING REQUIRED : (PER CALGREEN 5.106.5.2) BUILDING A/B/C/D (PUBLIC)12% X 245*= 30 CARS B.FUEL EFFICIENT VEHICLE PARKING PROVIDED:= 30 CARS (2 PROVIDED ON EAST SIDE SURFACE PARKING AND 28 PROVIDED IN (E) PARKING STRUCTURE) * NO REQUIREMENTS FOR GUESTROOMS PER CALGREEN CHATPTER 4. FUEL EFFICIENT VEHICLES CALCULATION IS BASED ON TOTAL STALLS FOR PUBLIC OF BULDINGS A/B/C/D. FUTURE ELECTRIC VEHICLES A.FUTURE ELECTRICAL VEHICLE PARKING REQUIRED (BUILDING C/D): GUESTROOM 6% X 207 = 13 CARS (PER CALGREEN 4.106.4.3.1) PUBLIC 10%X50 = 5 CARS (PER CALGREEN 5.106.5.3.3) TOTAL REQUIRED = 18 CARS TOTAL PROVIDED:= 19 CARS **EXISTING BUILDINGS A & B PARKING STALLS REQUIRED 195 STALLS -REQUIRED 452 TOTAL STALLS = 257 REQUIRED STALLS. FOR BUILDINGS C & D WE CALCULATED FUTURE ELECTRIC VEHICLE BASED ON BUILDINGS C & D PARKING REQUIREMENT. C.FUTURE CHARGING STATIONS QUALIFY AS DESIGNATED PARKING FOR FUEL EFFICIENT CLEAN AIR VEHICLES. FIRE DETECTION:ALARM SYSTEM WITH VOICE EVACUATION IN LOW RISE & HIGH RISE SMOKE DETECTION:SYSTEM IN LOW RISE AND HIGH RISE FIRE EXTINGUISHING SYSTEM:AUTOMATIC SPRINKLER -INSTALLED PER NFPA 13 - FULLY SPRINKLERED STANDPIPE SYSTEM:CLASS 1 ZONING ALLOWABLE HEIGHT: REMODELED BLDG. C: 48 FT (DOWNTOWN OVERLAY ZONE), 50'-4" ABOVE AVERAGE GRADE(APPROVED VARIANCE) NEW BLDG. D: 64'-0" ABOVE AVERAGE GRADE (APPROVED VARIANCE) AVERAGE GRADE PLANE HEIGHT: 476.0' ZONING HEIGHT PROPOSED (FROM AVERAGE GRADE POINT): REMODELED BLDG. C: 50'-3" ABOVE AVERAGE GRADE NEW BLDG. D: 63'-11 1/4" ABOVE AVERAGE GRADE BUILDING CODE HEIGHT: TYPE I-A UNLIMITED TYPE III-A 65' -0" BUILDING HEIGHT PROPOSED (FROM GRADE PLANE 476.0'): REMODELED BLDG. C: 49'-11" NEW BLDG. D: 60'-2" NUMBER OF STORIES ALLOWED: TYPE I-A UNLIMITED / TYPE III-A 4-STORIES NUMBER OF STORIES PROPOSED: REMODELED BLDG. C: BASEMENT (TYPE I-A) + 4 STORIES (TYPE I-A) NEW BLDG. D: 6 STORIES (4 STORIES TYPE III-A OVER 2 LEVEL TYPE1-A PODIUM) BUILDING SETBACKS: • REQUIRED FRONTYARD:NOT REQUIRED • REQUIRED SIDE YARD:NOT REQUIRED • REQUIRED REAR YARD:NOT REQUIRED 1. FIRE SPRINKLER SYSTEM (NFPA 13) 2. FIRE ALARM / SMOKE ALARM SYSTEM AND COMPLYING WITH 403.3 3. EMERGENCY VOICE / ALARM COMMUNICATION SYSTEM 4. EMERGENCY RADIO RESPONDER COVERAGE 5. POOL AND SPA 6. FOOD SERVICE KITCHEN EQUIPMENT ANCHORAGE 7. WINDOW WASHING SYSTEMS AND TIE-DOWN ANCHORS (FACADE ACCESS) 8. RETAINING WALLS / BLOCK FENCE WALLS 9. PEDESTRIAN PROTECTION PLAN 10. EMERGENCY GENERATOR AND FUEL TANK TOTAL REQUIRED (PUBLIC AND BOH -BLDG C B1-L1, BLDG D L1-L2): WATER CLOSET -MALE: 5 WATER CLOSET -FEMALE: 12 URINALS: 4 LAVATORY -MALE: 4 LAVATORY -FEMALE: 5 DRINKING FOUNTAIN: 2* (SEE NOTE 3) TOTAL REQUIRED (PUBLIC POOL-POOL USER) WATER CLOSET -MALE: 1 WATER CLOSET -FEMALE: 1 URINALS: 1 LAVATORY -MALE: 1 LAVATORY -FEMALE: 1 DRINKING FOUNTAIN: 1 SHOWER:1 TOTAL PROVIDED: WATER CLOSET 20 URINALS: 4 LAVATORY 16 DRINKING FOUNTAIN: 2 SHOWER (FOR POOL USER): 1 NOTE: 1. PER CBC SECTION 3116B.1 EXCEPTION, PUBLIC TOILET FACILITIES ARE NOT REQUIRED FOR POOL USER. 2. PER CBC SECTION 3117B.1 EXCEPTION, DRINKING FOUNTAIN IS NOT REQUIRED FOR POOL USER. 3. PER CPC 415.2 DRINKING FOUNTAIN ALTERNATIVES, WHERE FOOD IS CONSUMED INDOORS, WATER STATIONS SHALL BE PERMITTED TO BE SUBSTITUTED FOR DRINKING FOUNTAINS. TOTAL REQUIRED (BLDG C ROOF): WATER CLOSET -MALE: 1 WATER CLOSET -FEMALE: 2 URINALS: 1 LAVATORY -MALE: 1 LAVATORY -FEMALE: 1 DRINKING FOUNTAIN: 1 TOTAL PROVIDED (BLDG C ROOF): WATER CLOSET -MALE: 1 WATER CLOSET -FEMALE: 2 URINALS: 1 LAVATORY -MALE: 1 LAVATORY -FEMALE: 1 DRINKING FOUNTAIN: 1 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 5/ 1 3 / 2 0 2 5 5 : 4 6 : 2 6 P M G0.01 PROJECT INFORMATION HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. PROJECT SCOPE PROJECT DATA SUMMARY CODE REFERENCE DEFERRED SUBMITTALS OCCUPANCY SEPARATION OCCUPANCY A R S-2, U B, M, S-1 A - 1 - 1 R 1 - 1 1 S-2, U - 1 - 1 B, M, S-1 1 1 1 - FIRE SEPARATION REQUIREMENTS (HOURS) FOR FULLY SPRINKLERED BUILDING PER CBC TABLE 508.4 GUESTROOM MATRIX BLDG. C NAME COUNT KING C.1 7 QQ C.1 4 QQ C.3 1 QQ C.3 ACC. 1 BLDG. C & D LEVEL 1 13 KING C.1 12 KING C.2 1 KING C.2 ACC. 1 KING C.3 3 KING C.4 10 QQ C.1 9 QQ C.3 1 SUITE C.1 ACC. 1 BLDG. C (E) LEVEL 2 38 KING C.1 13 KING C.2 2 KING C.3 3 KING C.4 10 QQ C.1 8 QQ C.3 1 SUITE C.1 1 SUITE C.5 BALC. ACC. 1 SUITE C.5 BALC. 1 BLDG.C (E) LEVEL 3 40 TOTAL 91 PROJECT SUMMARYPLUMBING COUNT PARKING CALCULATIONS GUESTROOMS WITH MOBILITY FEATURES NUMBER NAME TUB / R.I.S. C 101 QQ C.3 ACC. TUB C 221 SUITE C.1 ACC. TUB C 224 KING C.2 ACC. R.I.S. C 322 SUITE C.5 BALC. ACC. TUB D 311 KING D.2 ACC. TUB D 327 SUITE D.2 ACC. R.I.S. D 411 QQ D.2 ACC. TUB (C.F.) D 626 1BR D.1 ACC. TUB GUESTROOMS WITH COMMUNICATION FEATURES NUMBER NAME C 114 KING C.1 C 201 KING C.3 C 218 KING C.2 C 225 QQ C.1 C 302 QQ C.3 C 321 SUITE C.1 C 332 KING C.4 C 341 KING C.3 D 312 KING D.3 D 315 QQ D.1 D 411 QQ D.2 ACC. D 511 KING D.2 D 526 1BR D.1 D 617 KING D.1 TOTAL: 14 FIRE / LIFE SAFETY REQUIREMENTS BUILDING HEIGHT / NO. OF STORIES BUILDING SETBACKS SCALE: 12" = 1'-0" SEPARATE PERMITS GROSS BUILDING & OCCUPANCY AREAS FIRE SEPARATION REQUIREMENTS TABLE 601 - FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) Key Name BUILDING ELEMENT TYPE I TYPE III A A 1 PRIMARY STRUCTURAL FRAME (SEE SECTION 202) 3 1 2 BEARING WALLS - EXTERIOR 3 2 3 BEARING WALLS - INTERIOR 3 1 4 NONBEARING WALLS AND PARTITIONS - EXTERIOR SEE TABLE 602 SEE TABLE 602 5 NONBEARING WALLS AND PARTITIONS - INTERIOR 0 0 6 FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (SEE SECTION 202)2 1 7 ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS (SEE SECTION 202)1 1/2 1 EAST SIDE SURFACE PARKING COUNT - BY TYPE TYPE NO. OF STALLS PERCENTAGE ACCESSIBLE ACCESSIBLE 2 4% 2 4% ACCESSIBLE - EV SPACE ACCESSIBLE - EV SPACE 1 2% 1 2% ACCESSIBLE VAN ACCESSIBLE VAN 1 2% 1 2% ACCESSIBLE VAN - EV SPACE ACCESSIBLE VAN - EV SPACE 1 2% 1 2% EV SPACE EV SPACE 17 35% 17 35% STANDARD STANDARD 26 54% 26 54% TOTAL 48 100% PLUMBING COUNT - B OCCUPANCY (PER CPC TABLE 422.1) NO NAME OCC. AREA OCC. FACTOR OCC. LOAD OL / 2 BLDG.C (E) BASEMENT B01 LAUNDRY B 1,604 SF 150 10.7 5.3 B02 ENGINEERING OFFICE B 196 SF 150 1.3 0.7 B04 HKPG OFFICE B 61 SF 150 0.4 0.2 B 1,861 SF 12.4 6.2 BLDG. C & D LEVEL 1 C 141 LUGG./BIKE STORAGE B 69 SF 200 0.3 0.2 C 142 I.T. ROOM B 69 SF 200 0.3 0.2 C 143 OFFICE B 101 SF 150 0.7 0.3 C 144 OFFICE B 111 SF 150 0.7 0.4 C 145 ADMIN B 239 SF 150 1.6 0.8 C 146 FRONT DESK B 354 SF 150 2.4 1.2 C 152 BOH B 406 SF 150 2.7 1.4 C 157 SERVICE STATION B 66 SF 150 0.4 0.2 D 118 F&B OFFICE B 55 SF 150 0.4 0.2 B 1,469 SF 9.6 4.8 TOTAL 3,330 SF 22 11 GUESTROOM MATRIX BLDG. D NAME COUNT 1BR D.1 1 KING D.1 8 KING D.2 ACC. 1 KING D.3 2 QQ D.1 9 SUITE D.2 ACC. 1 BLDG. D LEVEL 3 22 1BR D.1 1 KING D.1 8 KING D.3 2 QQ D.1 9 QQ D.2 ACC. 1 SUITE D.2 1 BLDG. D LEVEL 4 22 1BR D.1 1 KING D.1 8 KING D.2 1 KING D.3 2 QQ D.1 9 SUITE D.2 1 BLDG. D LEVEL 5 22 1BR D.1 ACC. 1 KING D.1 6 KING D.2 1 QQ D.1 7 SUITE D.2 1 BLDG. D LEVEL 6 16 TOTAL 82 BUILDING C = 91 GUESTROOMS BUILDING D = 82 GUESTROOMS TOTAL = 173 GUESTROOMS (100%) GUESTROOM COUNT NAME COUNT PERCENTAGE 1BR D.1 3 2% 1BR D.1 ACC. 1 1% KING C.1 32 18% KING C.2 3 2% KING C.2 ACC. 1 1% KING C.3 6 3% KING C.4 20 12% KING D.1 30 17% KING D.2 2 1% KING D.2 ACC. 1 1% KING D.3 6 3% QQ C.1 21 12% QQ C.3 3 2% QQ C.3 ACC. 1 1% QQ D.1 34 20% QQ D.2 ACC. 1 1% SUITE C.1 1 1% SUITE C.1 ACC. 1 1% SUITE C.5 BALC. ACC. 1 1% SUITE C.5 BALC. 1 1% SUITE D.2 3 2% SUITE D.2 ACC. 1 1% TOTAL 173 100% TABLE 602 - FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALL... FSD FIRE-RESISTANCE RATING (HOURS) X < 5 1 5 ≤ X < 10 1 10 ≤ X < 30 1 X ≥ 30 0 TABLE 705.8 - FIRE SEPARATION DISTANCE (FSD) AND OPENING PROTECTION FIRE SEPARATION DISTANCE % UNPROTECTED OPENINGS ALLOWED IN SPRINKLERED BUILDING PER CBC TABLE 705.8 5' ≤ FSD < 10' 25% 10' ≤ FSD < 15' 45% 15' ≤ FSD < 20' 75% 20' ≤ FSD NO LIMIT PLUMBING COUNT - ROOF TOP (PER CPC TABLE 422.1) NO NAME OCC. AREA OCC. FACTOR OCC. LOAD OL / 2 BLDG. C ROOFTOP PATIO C 401 DINING A-2 2,097 SF 30 69.9 35 C 401.1 DINING A-2 417 SF 30 13.9 7 C 402 BAR A-2 210 SF 50 4.2 2.1 C 403 PANTRY A-2 378 SF 50 7.6 3.8 A-2 3,104 SF 95.6 47.8 TOTAL 3,104 SF 95.6 47.8 PLUMBING COUNT - A OCCUPANCY (PER CPC TABLE 422.1) NO NAME OCC. AREA OCC. FACTOR OCC. LOAD OL / 2 BLDG. C & D LEVEL 1 C168 SOBA PREP A-2 44 SF 50 0.9 0.4 C169 SERV A-2 46 SF 50 0.9 0.5 C 147 EXECUTIVE LOUNGE A-2 771 SF 30 25.7 12.9 C 149 LOBBY A-2 1,475 SF 30 49.2 24.6 C 150 BAR LOUNGE A-2 1,387 SF 30 46.2 23.1 C 151 BAR A-2 229 SF 50 4.6 2.3 C 154 KITCHEN A-2 1,076 SF 50 21.5 10.8 C 158 BOARD ROOM A-2 215 SF 30 7.2 3.6 C 159 MEETING ROOM A-2 597 SF 30 19.9 10 C 161 RESTAURANT DINING (THE OVALO)A-2 2,054 SF 30 68.5 34.2 C 162 V.I.P DINING 2 A-2 205 SF 30 6.8 3.4 C 163 V.I.P DINING 1 A-2 281 SF 30 9.4 4.7 C 164 JAPANESE RESTAURANT DINING A-2 862 SF 30 28.7 14.4 C 165 JAPANESE RESTAURANT KITCHEN A-2 532 SF 50 10.6 5.3 C 166 JAPANESE RESTAURANT V.I.P. SEATING A-2 270 SF 30 9 4.5 D 104 KITCHEN A-2 613 SF 50 12.3 6.1 D 113 PREFUNCTION A-2 1,436 SF 30 47.9 23.9 D 114 BANQUET ROOM #1 A-2 3,672 SF 30 122.4 61.2 D 115 BANQUET ROOM #2 A-2 3,443 SF 30 114.8 57.4 D 117 STAGING A-2 375 SF 50 7.5 3.7 D 120 OUTDOOR LOUNGE A-2 2,333 SF 30 77.8 38.9 D 126 COURTYARD A-2 3,271 SF 30 109 54.5 D 127 WARMING KITCHEN/ SERVING SETUP A-2 280 SF 50 5.6 2.8 A-2 25,468 SF 806.3 403.2 D 102 FITNESS CENTER A-3 1,068 SF 50 21.4 10.7 A-3 1,068 SF 21.4 10.7 BLDG. D LEVEL 2 D 206 EMPLOYEE LOUNGE A-3 853 SF 30 28.4 14.2 A-3 853 SF 28.4 14.2 TOTAL 27,389 SF 856.1 428.1 GROSS BUILDING AREA (CBC) - BY LEVEL BLDG NAME LEVEL AREA BLDG.1 BLDG.1 LEVEL 1 45,902 SF BLDG.1 LEVEL 2 26,751 SF BLDG.1 LEVEL 3 24,631 SF BLDG.1 LEVEL 4 (ROOF) 2,692 SF 99,976 SF BLDG.2 BLDG.2 LEVEL 3 14,190 SF BLDG.2 LEVEL 4 14,307 SF BLDG.2 LEVEL 5 14,151 SF BLDG.2 LEVEL 6 10,776 SF 53,424 SF TOTAL: 153,400 SF GROSS BUILDING AREA (CBC) - TOTALS NAME AREA BLDG.1 A-2 25,971 SF A-3 8,939 SF B 1,681 SF HORIZONTAL PROJECTION 8,841 SF R-1 51,059 SF S-1 2,270 SF S-2 1,216 SF BLDG.2 HORIZONTAL PROJECTION 5,043 SF R-1 48,381 SF TOTAL: 153,400 SF PLUMBING COUNT - PUBLIC POOL (PER CBC SECTION 3116B) NO NAME OCC. AREA OCC. FACTOR OCC. LOAD OL / 2 BLDG. C & D LEVEL 1 D 124 POOL A-3 740 SF 15 49.3 24.7 A-3 740 SF 49.3 24.7 TOTAL 740 SF 49.3 24.7 NO.DATE ISSUES & REVISIONS 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) 02.26.24 BULLETIN 5 07.29.24 BULLETIN 9 01.31.25 BULLETIN 11 05.12.25 BULLETIN 13 05/21/2025 CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________EP 05/21/2025 25-1009 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T S SD WAP FP H H M/D ? 1i A101 1 A101 SIM GRID LINE SECTION IDENTIFICATION DWG SHEET NUMBER DETAIL NUMBER DWG SHEET NUMBER SPECIFIC ELEVATION DWG SHEET NUMBER ROOM/SPACE DESCRIPTION ROOM NUMBER AREA (SQ. FEET) REVISION KEY ELEVATION DATUM KEYNOTE DOOR NUMBER WINDOW TYPE ALIGN 1 1 1 1 DESCRIPTION OF SIM OR OPP DESCRIPTION OF SIM OR OPP 1t XX LEVEL 2 + 12' -0" A 1 A101 1 SIM INTERIOR ELEVATION SPECIFIC ELEVATION DWG SHEET NUMBER EXTERIOR ELEVATION N 1 A101 SIM 10.23 NORTH ARROW REFERENCE T-1 CPT-1 CHANGE IN FLOOR FINISH ALIGN XX XX 0000.0 XXX CL WORK, CONTROL OR ELEVATION POINT CENTERLINE SLAB STEP #' - ##" #'' - ##" #' - ##" DIMENSION AT GRIDLINE, FACE OF FRAMING OR STRUCTURE DIMENSION AT CENTERLINE CL CL DIMENSION AT FACE OF FINISH OR CLEAR DIMENSION PROPERTY LINE A1.01 1 SPECIFIC VIEW DWG SHEET NUMBER PERSPECTIVE VIEW MATERIAL TAG?CP1 PL 12 1 SLOPE RISE:RUN STUD SIZE FIRE RATING (HR) MODIFIER (SEE A8.01 FOR MATRIX) 'X' IF EXTERIOR WALL TYPE PARTITION TYPE -SEE A8.01 FOR DETAILS PARTITION TAG ACOUSTIC CEILING TILE GYPSUM BOARD CEILING RECESSED LIGHT FIXTURE 1 X 4 FLUORESCENT FIXTURE 2 X 2 FLUORESCENT FIXTURE LINEAR RECESSED LIGHT FIXTURE RECESSED DOWN LIGHT WALL WASHER FIRE ALARM SMOKE DETECTOR WIRELESS INTERNET CEILING MOUNTED SPRINKLER HEAD TRACK LIGHTING EXIT SIGN (AT R1 OCCUPANCY ALSO PROVIDE LOW LEVEL EXIT SIGNS) ACCESS PANEL SUPPLY GRILLE LINEAR DIFFUSER RETURN GRILLE EXHAUST GRILLE SPEAKER A.F.F.8'-0" CLG. TYPE CEILING STEP CEILING TAG EXPOSED CONCRETE FINISHED CONCRETE F CEILING MOUNTED EXIT SIGN, SHOW QUANTITY OF FACE(S) AND DIRECTION OF ARROW(S) WALL MOUNTED EXIT SIGN, SHOW QUANTITY OF FACE(S) AND DIRECTION OF ARROW(S) INDIRECT LINEAR LIGHT FIXTURE WALL MOUNTED SPRINKLER HEAD FIRE ALARM PULL BOX CEILING MOUNTED HORN / STROBE COMBO WALL MOUNTED HORN / STROBE COMBO SURFACE / PENDANT MTD LIGHT FIXTURE WALL SCONCE (MUD IN) SURFACE MOUNTED LIGHT FIXTURE EMERGENCY LIGHT (BUG EYE) MOTION / DAYLIGHT SENSOR WALL MOUNTED SINGLE OUTLET WALL MOUNTED DUPLEX OUTLET WALL MOUNTED DUPLEX GROUND FAULT INTERRUPTER OUTLET WALL MOUNTED QAUDRUPLEX OUTLET WALL MOUNTED QUADRUPLEX GROUND FAULT INTERRUPTER OUTLET WALL MOUNTED SINGLE SWITCH WALL MOUNTED DOUBLE SWITCH WALL MOUNTED TRIPLE SWITCH WALL MOUNTED DIMMER SWITCH WALL MOUNTED VOICE RECEPTACLE WALL MOUNTED DATA RECEPTACLE WALL MOUNTED VOICE/DATA RECEPTACLE FLOOR MOUNTED SINGLE RECEPTACLE FLOOR MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED QUADRUPLEX RECEPTACLE FLOOR MOUNTED VOICE RECEPTACLE FLOOR MOUNTED DATA RECEPTACLE FLOOR MOUNTED VOICE/DATA RECEPTACLE FLOOR MOUNTED ELECTRICAL JUNCTION BOX FLOOR MOUNTED FURNITURE WHIP POWER POLE, POWER/DATA/VOICE FEED WALL MOUNTED ELECTRICAL JUNCTION BOX CEILING MOUNTED ELECTRICAL JUNCTION BOX TELEVISION WALL MOUNTED DUPLEX W/ USB PORTS BLANK PLATE FIRE EXTINGUISHER WITHOUT CABINET FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FIRE VALVE WITHOUT CABINET FIRE VALVE CABINET CARD READER WALL MOUNTED THERMOSTAT AUDIO VISUAL LOCATION OF CONDUIT STUB UP FROM SLAB FOR POWER & CONNECTED WITH FLEXIBLE METAL CONDUIT & WIRED DIRECTLY TO OUTLETS LOCATION OF CONDUIT STUB UP FROM SLAB FOR DATA & CONNECTED WITH FLEXIBLE METAL CONDUIT & WIRED DIRECTLY TO DATA OUTLETS LOCATION OF CONDUIT STUB UP FROM SLAB FOR TV CABLE & CONNECTED DIRECTLY TO CABLE BOX 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 0 2 A M G2 SYMBOLS & ABBREVIATIONS (TI) HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SYMBOLS SYMBOLS - REFLECTED CEILING PLAN 1 & AND 1 < ANGLE 1 @ AT 1 CL CENTERLINE 1 Ø DIAMETER OR ROUND 1 (E) EXISTING 1 (N) NEW 1 # POUND OR NUMBER A ABV. ABOVE A A.F.F. ABOVE FINISH FLOOR A ACC. / ACCS. ACCESSIBLE A A.P.C. ACOUSTIC PANEL CEILING A ACOUS. ACOUSTICAL A A.C.T. ACOUSTICAL CEILING TILE A ADJ. ADJACENT A ADJ. ADJUSTABLE A AGG. AGGREGATE A AWB AIR AND WATER RESISTIVE BARRIER A AL. / ALUM. ALUMINUM A ANSI AMERICAN NATIONAL STANDARDS SOCIETY A ASTM AMERICATION SOCIETY FOR TESTING AND MATERIALS A A.B. ANCHOR BOLT A ANOD. ANODIZED A APPROX. APPROXIMATELY A ARCH. ARCHITECTURAL A A.E.S.S. ARCHITECTURALLY EXPOSED STRUCTURAL STEEL A A.D. AREA DRAIN A AOR AREA OF REFUGE A ASPH. ASPHALT A A.C. ASPHALTIC CONCRETE A ASSEM. ASSEMBLY B BM. BEAM B BTW BETWEEN B BYND BEYOND B BITUM. BITUMINOUS B BLK. BLOCK B BLKG. BLOCKING B BD. BOARD B B.S. BOTH SIDES B B.O. BOTTOM OF ... B BLDG. BUILDING C CAB. CABINET C CPT. CARPET C C.I.P. CAST IN PLACE C C.I. CAST IRON C C.B. CATCH BASIN C CLKG CAULKING C CLG. CEILING C CEM. CEMENT C C.P. CEMENT PLASTER C CTR. CENTER C CTR. CENTER C CER. CERAMIC C C.T. CERAMIC TILE C CHNL. CHANNEL C CHK'D CHECKERED C C.O. CLEAN OUT OR CASED OPENING C CLR. CLEAR C CLST. CLOSET C CFA COLD FLUID APPLIED C C.W. COLD WATER C COL. COLUMN C CSP. COMBINATION STANDPIPE C C.F. COMMUNICATION FEATURES C CONC. CONCRETE C CMU CONCRETE MASONRY UNIT C C.S.B. CONCRETE SPLASH BLOCK C COND. CONDITION C CONN. CONNECTION C CONSTR. CONSTRUCTION C CONT. CONTINUOUS C CONTR. CONTRACTOR C CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED C C.J. CONTROL JOINT C C.G. CORNER GUARD C CORR. CORRIDOR C CNTR. COUNTER C CTSK. COUNTERSUNK D DT DATA/COMMUNICATIONS OUTLET D DEMO. DEMOLISH / DEMOLITION D DEPT. DEPARTMENT D DET. DETAIL D DIA. DIAMETER D DIM. DIMENSION D DW. DISH WASHER D DISP. DISPENSER D DR. DOOR D D.O. DOOR OPENING D DBL. DOUBLE D DN DOWN D D.S. DOWNSPOUT D DWR. DRAWER D DWG. DRAWING D D.F. DRINKING FOUNTAIN ABBREVIATIONS SYMBOLS - POWER AND COMMUNICATION D DSP. DRY STANDPIPE E EA. EACH E E. EAST E E.O.S. EDGE OF SLAB E E.P. ELECTRIC PANELBOARD E E.W.C. ELECTRIC WATER COOLER E ELEC. / ELECT. ELECTRICAL E EL. ELEVATION E ELEV. ELEVATOR E EMER. EMERGENCY E E.PH. EMERGENCY PHONE E ENCL. ENCLOSURE E EQ. EQUAL E EQUIP. EQUIPMENT E EXST. EXISTING E EXP. EXPANSION E E.J. EXPANSION JOINT E EXP. / EXPO. EXPOSED E E.C. EXPOSED CONSTRUCTION E EXT. EXTERIOR F F.O.C. FACE OF CONCRETE F F.O.F. FACE OF FINISH F F.O.M. FACE OF MASONRY F F.O.S. FACE OF STUD F F.O. FACE OF... F F.C.U. FAN COIL UNIT F FRCP FIBER REINFORCED CEMENT PANEL F F.R.P. FIBERGLASS REINFORCED PLASTIC F FIN. FINISH F F.F. FINISH FACE F F.F. FINISH FLOOR F F.G. FINISH GRADE F F.O. FINISHED OPENING F F.A. FIRE ALARM F F.E. FIRE EXTINGUISHER F F.E.C. FIRE EXTINGUISHER CABINET F F.H.C. FIRE HOSE CABINET F F.R. FIRE RATED F F.R.T. FIRE RETARDENT TREATED F F.V.C. FIRE VALVE CABINET F FPRF. FIREPROOF F FIXT. FIXTURE F FLASH. FLASHING F F.B. FLAT BAR F FPD FLAT PANEL DISPLAY F FPM FLAT PANEL MONITOR F FLR. FLOOR F F.C.O. FLOOR CLEANOUT F F.D. FLOOR DRAIN F F.S. FLOOR SINK F F.L. FLOW LINE F FLUOR. FLUORESCENT F FT. FOOT OR FEET F FTG. FOOTING F FDN. FOUNDATION F FURR. FURRING F FUT. FUTURE G GALV. GALVANIZED G G.I. GALVANIZED IRON G G.S.M. GALVANIZED SHEET METAL G GALV.STL. GALVANIZED STEEL G GA. GAUGE G G.C. GENERAL CONTRACTOR G GL. GLASS G G.F.R.C. GLASS FIBER REINFORCED CONCRETE G G.B. GRAB BAR G GR. GRADE G GND. GROUND G GYP. BD. / GB GYPSUM BOARD H HDWR HARDWARE H HDWD HARDWOOD H HFA HEAT FLUID APPLIED H HTR. HEATER H HT. / HGT. HEIGHT H H. HIGH H HPC HIGH PERFORMANCE COATING H H.P. HIGH POINT H HO HOLD OPEN H H.C. HOLLOW CORE H H.M. HOLLOW METAL H HMWV HOLLOW METAL WOOD VENEER H HORIZ. HORIZONTAL H H.B. HOSE BIBB H H.W. HOT WATER H HR. HOUR I IN. INCHES I I.D. INSIDE DIAMETER I INSUL. INSULATION I INT. INTERIOR J JAN. JANITOR J JT. JOINT J JST. JOIST K KIT. KITCHEN L LAB. LABORATORY L LAM. LAMINATE L LAV. LAVATORY L L. LENGTH L LT. LIGHT L L.O.S. LINE OF SIGHT L LCKR. LOCKER L LG. LONG L LVR LOUVER L L.P. LOW POINT M MACH. MACHINE M MH. MANHOLE M MFR. MANUFACTURER M M. MASONRY M M.O. MASONRY OPENING M MATL. MATERIAL M MAX. MAXIMUM M MECH. MECHANICAL M M.C. MEDICINE CABINET M MEMB. MEMBRANE M MET. / MTL. METAL M M.D. METAL DECK M MEZZ. MEZZANINE M MWK. MILLWORK M MIN. MINIMUM M MIR. MIRROR M MISC. MISCELLANEOUS M MCP MODIFIED CEMENT PLASTER M MTD. MOUNTED M MUL. MULLION N NOM. NOMINAL N N. NORTH N N/A NOT APPLICABLE N N.I.C. NOT IN CONTRACT N N.T.S. NOT TO SCALE N NO. NUMBER O OBS. OBSCURE O OFF. OFFICE O O.C. ON CENTER O O.S. ONE SIDE O OPNG. OPENING O O.B.D. OPPOSED BLADE DAMPER O OPP. OPPOSITE O O.H. OPPOSITE HAND O O.A. OUTSIDE AIR O O.A.D. OUTSIDE AIR DAMPER O O.A.T. OUTSIDE AIR TEMPERATURE O O.D. OUTSIDE DIAMETER O O.H.S.M.S. OVAL HEAD SHEET METAL SCREW O O/ OVER O OVRAL OVERALL O O.F.D. OVERFLOW DRAIN O O.H.C. OVERHEAD COILING O OFCI OWNER FURNISHED CONTRACTOR INSTALLED O OFOI OWNER FURNISHED OWNER INSTALLED P PTD. PAINTED P PR. PAIR P PNL. PANEL P P.T.D. PAPER TOWEL DISPENSER P P.T.R. PAPER TOWEL RECEPTACLE P PRHT. PARTIAL-HEIGHT P PRTN PARTITION P PERF. PERFORATED P PCP PHENOLIC COMPOSITE PANEL P PLAS. PLASTER P P.LAM. PLASTIC LAMINATE P PL. PLATE P PLUMB. PLUMBING P PLYWD PLYWOOD P P.E.N. PLYWOOD EDGE NAILING P PNT. POINT P P.D.F. POWER DRIVEN FASTENERE P PC PRECAST P PREFAB PREFABRICATED P P.T. PRESSURE TREATED P PROP. PROPERTY LINE Q QTY QAUNTITY Q Q.T. QUARRY TILE Q Q.T.R. QUARRY TILE RISER R RAD. RADIUS R R.W.L. RAIN WATER LEADER R RWD. REDWOOD R REF. REFERENCE R R.C.P. REFLECTED CEILING PLAN R REFR. REFRIGERATOR R RGTR. REGISTER R REINF. REINFORCED R REQD. REQUIRED R RESIL. RESILIENT R R.O.W. RIGHT OF WAY R R. RISER R R.D. ROOF DRAIN R RM. ROOM R R.O. ROUGH OPENING R R.B. RUBBER BASE S SPL. RECESSED SPILL KIT S S.N.D. SANITARY NAPKIN DISPENSER S S.N.R. SANITARY NAPKIN RECEPTACLE S SCHED. SCHEDULE S SCU. SCUPPER S S.C.D. SEAT COVER DISPENSER S SEC. SECTION S SECT. SECTION S S.C.D. SEE CIVIL DRAWINGS S S.E.D. SEE ELECTRICAL DRAWINGS S S.I.D.D. SEE INTERIOR DESIGN DRAWINGS S S.L.D. SEE LANDSCAPE DRAWINGS S S.M.D. SEE MECHANICAL DRAWINGS S S.P.D. SEE PLUMBING DRAWINGS S S.S.D. SEE STRUCTURAL DRAWINGS S S.SK. SERVICE SINK S SHT. SHEET S SHWR. SHOWER S SIM. SIMILAR S SL. SLOPE S S.D. SOAP DISPENSER S S.C.P. SOLID COMPOSITE PANEL S S.C. SOLID CORE S S. SOUTH S SPEC. / SPECS. SPECIFICATION S SQ. SQUARE S SST. STAINLESS STEEL S STD. STANDARD S S.P. STANDPIPE S STA. STATION S STL. STEEL S STOR. STORAGE S STRUCT. STRUCTURAL S SUSP. SUSPENDED S SYM. SYMMETRICAL T TEL. TELEPHONE T TV. TELEVISION T THK. THICK / THICKNESS T THRU. THROUGH T T.B.D. TO BE DETERMINED T T.P.D. TOILET PAPER DISPENSER T T. & G. TONGUE AND GROOVE T T. & B. TOP AND BOTTOM T T.O.C. TOP OF CURB T T.O.P. TOP OF PARAPET T T.P. TOP OF PAVEMENT T T.O.S. TOP OF STEEL / TOP OF SLAB T T.OW. TOP OF WALL T T.B. TOWEL BAR T T. TREAD T TYP. TYPICAL U U.L. UNDERWRITERS LABORATORIES U UNF. UNFINISHED U U.O.N. UNLESS OTHERWISE NOTED U UR. URINAL V V.I.F. VERIFY IN FIELD V VERT. VERTICAL V VEST. VESTIBULE W W.R.G.B. MOISTURE RESISTANT GYPSUM BOARD W WSCT. WAINSCOT W W/D WASHER & DRYER W W.C. WATER CLOSET W W.H. WATER HEATER W WP WATERPOOF / WATERPROOFING W W.R.B. WEATHER RESISTIVE BARRIER W WT. WEIGHT W W. WEST W W.O. WHERE OCCURS W WDW. WINDOW W W/ WITH W W/O WITHOUT W WD. WOOD W W.B. WOOD BASE W WRK. PT. WORK POINT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 UP W W FP FP 4 Y D TR A S H 4 YD TRA S H 4 Y D TR A S H 4 YD TRA S H 4 Y D TR A S H 4 YD TRA S H 4 Y D TR A S H 4 YD TRA S H EDISONUTILITIES 1" : 12"MAX DN 1" : 12"DN 1" : 12" DN GM SLPB VISIBILIT Y T RIA N G L E 30'COLORADO PLACE SLOPE SLOPE SLOPE DN UP UP DN DN UP SD DN 3-COMP BAR SINK 60"HANDSINKMIXOLOGY SINK 12" COFFEEGRINDERS ESPRESSOMACHINE MIXOLOGY SINK 12" ICEMAKER27" COFFEEGRINDERS BOTTLE COOLER 36"BLENDER,BEVERAGE POSBEERDISPENSER 60" UNDERBAR LIQUOR DISPLAY18" UNDERBAR LIQUOR DISPLAY 18" ICE BIN 36" ICE BIN 36" BACK BARCOOLER60" UP UP LOBBY C 149 QQ C.3 ACC. TUB C 101 FITNESS CENTER D 102 BANQUET ROOM #1 D 114 BANQUET ROOM #2 D 115V.I.P DINING 2 C 162 FUTURE JAPANESE RESTAURANT C 164 BOARD ROOM C 158 HALLWAY C 160 EXECUTIVE LOUNGE C 147 BAR LOUNGE C 150 SERVICE CORRIDOR D 116 QQ C.1 C 112 V.I.P DINING 1 C 163RESTAURANT DINING (THE OVALO) C 161 MEETING ROOM C 159KITCHEN C 154 LAUNDRY B01 ENGINEERING OFFICE B02 ACCESSIBLE PATH OF TRAVEL MINIMUM 44" WIDE WITH MAXIMUM 5% SLOPE AND 2% CROSS SLOPE MOBILITY ACCESSIBLE PARKING STALL OR GUEST UNIT COMMUNICATION ACCESSIBLE GUEST UNIT LEGEND 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 7/ 3 0 / 2 0 2 4 3 : 3 3 : 4 3 P M G0.44 BLDG. C PATH OF TRAVEL HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. N SCALE: 1/16" = 1'-0"G0 . 4 41BLDG. C & D PATH OF TRAVEL PLAN - LEVEL 1 SCALE: 1/16" = 1'-0"G0 . 4 42BLDG. C PATH OF TRAVEL PLAN - BASEMENT NO.DATE ISSUES & REVISIONS 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) 07.29.24 BULLETIN 9 09/16/2024 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T FP (E) PARKING GARAGE BUILDING B SS SS W W W FP FP 4 YD TRA S H 4 Y D TRA S H 4 YD TRA S H 4 Y D TRA S H 4 YD TRA S H 4 Y D TRA S H 4 YD TRA S H 4 Y D TRA S H EDISONUTILITIES 1" : 12"MAX DN 1" : 12" DN 1" : 12"DN 1" : 12"DN LEFTTURNONLY GM SLPB SLPB CONC SIDEWALK VISIBILIT Y T RIA N G LE 30' H U N T I N G T O N D R . SAN RAFAEL ROAD HUNTINGTON DR. COLORADO PLACE C LE A N AIR V E C HICL E C LE A N AIR VE C HICL E C LE A N AIR VE C HICL E C LEAN AIR VECHIC LE CLEAN AIR VECHIC LE C LEAN AIR VECHIC LE CLEAN AIR V ECHIC LE C LE A N AIR VE C HICL E CLE A N AIR V E C HICL E C LEAN AIR VEC HICLE C LEAN AIR VEC HIC LE C LEAN AIR VEC HICLE D N HOISTWAY PLAN O P E N A I R V E N T HS SELECT. S SLOPE SLOPE SLOPE SLOPE W STOP STOP STOP STOPSTOP STOP UP DN UPDN DN UP DN UP SIDEWALK PLANTER SIDEWALK TRASH DROP-OFF BIKE PARKING LOADING COURTYARD TERRACE BUILDING D NEW 6-STORY BUILDING F.F.E. 476.60' BUILDING C EXISTING 3-STORY BUILDING TO BE RENOVATED F.F.E. 476.60' CANOPY ABOVE OUTDOOR PATIO PORTE COCHERE PLANT ER PLANTER SIDEWALK PARKING OVERHANG, TYP. BENCH PLANTER (E) TRANSFORMER (APPOX SIZE 143"X 50.4" X 91.7" HIGH) (E) GENERATOR DINING TERRACE TERRACE POOL 18' 6" X 40' BL D G . D BL D G . C ROOM NUMBER AREA OCCUPANT LOAD FACTOR PER CBC 2019 TABLE 1004.5 OCCUPANT LOAD ACCUMULATED LOAD AND TRAVEL DIRECTION EGRESS PATH OF TRAVEL EXIT STAIR OL - ### OF : ### ##" REQUIRED ##" PROVIDED EXIT DOOR OL - ### OF : ### ##" REQUIRED ##" PROVIDED CAPACITY FACTOR PER CBC 2019 SECTION 1005.3.2 REQUIRED WIDTH DOOR LOAD PROVIDED WIDTH ### LEGEND CAPACITY FACTOR PER CBC 2019 SECTION 1005.3.1 REQUIRED WIDTH STAIR LOAD PROVIDED WIDTH ROOM NAME 101 150 SF OF : ### OL - ### NON-RATED WALL 1-HOUR FIRE PROTECTED WALL 1-HOUR RATED WALL 2-HOUR RATED WALL 2-HOUR FIRE PROTECTED WALL 3-HOUR RATED WALL 4-HOUR RATED WALL CONCRETE WALL CONCRETE MASONRY UNIT WALL WALL TYPES 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 11/21/2023 3:40:07 PM G0.51 EXITING SITE PLAN HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. SCALE: 1" = 20'-0"G0 . 5 11EXITING SITE PLAN NO.DATE ISSUES & REVISIONS 11.08.23 PLAN CHECK11.21.23 PERMIT SET 11/28/2023 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T UP DN UP UP DN DN UP SD DN UP ROOM NUMBER AREA OCCUPANT LOAD FACTOR PER CBC 2019 TABLE 1004.5 OCCUPANT LOAD ACCUMULATED LOAD AND TRAVEL DIRECTION EGRESS PATH OF TRAVEL EXIT STAIR OL - ### OF : ### ##" REQUIRED ##" PROVIDED EXIT DOOR OL - ### OF : ### ##" REQUIRED ##" PROVIDED CAPACITY FACTOR PER CBC 2019 SECTION 1005.3.2 REQUIRED WIDTH DOOR LOAD PROVIDED WIDTH ### LEGEND CAPACITY FACTOR PER CBC 2019 SECTION 1005.3.1 REQUIRED WIDTH STAIR LOAD PROVIDED WIDTH ROOM NAME 101 150 SF OF : ### OL - ### 239 SF OL - 2 ADMIN C 145 OF : 150 69 SF OL - 1 I.T. ROOM C 142 OF : 300 69 SF OL - 1 LUGG./BIKE STORAGE C 141 OF : 300 358 SF OL - 2 ELEC. C 113 OF : 300 42 SF OL - 1 RISER ROOM C 115 OF : 300 26 SF OL - 1 BANQUET STORAGE D 112 OF : 300 117 SF OL - 1 DOMESTIC WATER PUMP ROOM D 132 OF : 200 1,436 SF OL - 96 PREFUNCTION D 113 OF : 15 88 SF OL - 1 RISER RM. D 006 OF : 300 107 SF OL - 1 MDF RM D 005A OF : 300349 SF OL - 2 ELEC. D 005 OF : 300 406 SF OL - 3 BOH C 152 OF : 150 Not Enclosed OL - 0 POOL EQUIP. D 004 OF : 300 2,054 SF OL - 137 RESTAURANT DINING (THE OVALO) C 161 OF : 15 771 SF OL - 52 EXECUTIVE LOUNGE C 147 OF : 15 229 SF OL - 2 BAR C 151 OF : 150 354 SF OL - 3 FRONT DESK C 146 OF : 150 1,475 SF OL - 99 LOBBY C 149 OF : 15 215 SF OL - 15 BOARD ROOM C 158 OF : 15 1,387 SF OL - 93 BAR LOUNGE C 150 OF : 15 505 SF OL - 3 QQ C.3 ACC. C 101 OF : 200 426 SF OL - 3 KING C.1 C 103 OF : 200 416 SF OL - 3 QQ C.1 C 105 OF : 200 420 SF OL - 3 KING C.1 C 107 OF : 200 421 SF OL - 3 KING C.1 C 109 OF : 200 410 SF OL - 3 QQ C.1 C 112 OF : 200 417 SF OL - 3 KING C.1 C 110 OF : 200 417 SF OL - 3 KING C.1 C 108 OF : 200 412 SF OL - 3 QQ C.1 C 106 OF : 200 424 SF OL - 3 KING C.1 C 104 OF : 200 461 SF OL - 3 QQ C.3 C 102 OF : 200 740 SF OL - 15 POOL D 124 OF : 50 2,333 SF OL - 156 OUTDOOR LOUNGE D 120 OF : 15 1,942 SF OL - 130 POOL DECK D 123 OF : 15 EXIT DOOR 68" REQUIRED 71 5/8" PROVIDED OL - 337 OF : 0.2 EXIT DOOR 34" REQUIRED 71 5/8" PROVIDED OL - 169 OF : 0.2 EXIT STAIR 27" REQUIRED OL - 87 OF : 0.3 48" PROVIDED 111 SF OL - 1 OFFICE C 144 OF : 150 101 SF OL - 1 OFFICE C 143 OF : 150 146 SF OL - 1 DRY STORAGE D 107 OF : 300 3,672 SF OL - 245 BANQUET ROOM #1 D 114 OF : 15 3,443 SF OL - 230 BANQUET ROOM #2 D 115 OF : 15 125 1,068 SF OL - 22 FITNESS CENTER D 102 OF : 50 EXIT DOOR 25" REQUIRED 68 1/2" PROVIDED OL - 125 OF : 0.2 EXIT DOOR 24" REQUIRED 68 1/2" PROVIDED OL - 117 OF : 0.2 EXIT DOOR 34" REQUIRED 71 5/8" PROVIDED OL - 170 OF : 0.2 EXIT DOOR 1" REQUIRED 34 1/4" PROVIDED OL - 1 OF : 0.2 E XIT S E P A R A TIO N: M A X DIA G O N A L DIS T A N C E: 8 3'-1 0" 8 3'-1 0" E X I T S E P A R A T I O N : M A X D I A G O N A L D I S T A N C E : 8 6'- 1 0 " 8 6'- 1 0 " EXIT SEPARATION: 64'-7" E X I T S E P A R A T I O N : 6 2 '-6 " 264 SF OL - 2 WARMING KITCHEN/ SERVING SETUP D 127 OF : 200 617 SF OL - 4 KITCHEN D 104 OF : 200 375 SF OL - 2 STAGING D 117 OF : 200 117 20 3 EXIT DOOR 1" REQUIRED 34 1/4" PROVIDED OL - 3 OF : 0.2 4 415 SF OL - 3 QQ C.1 C 111 OF : 200 418 SF OL - 3 KING C.1 C 114 OF : 200 22 EXIT DOOR 5" REQUIRED 34 1/4" PROVIDED OL - 22 OF : 0.2 597 SF OL - 40 MEETING ROOM C 159 OF : 15 974 SF OL - 65 FUTURE JAPANESE RESTAURANT C 164 OF : 15 205 SF OL - 14 V.I.P DINING 2 C 162 OF : 15 281 SF OL - 19 V.I.P DINING 1 C 163 OF : 15 1,028 SF OL - 6 KITCHEN C 154 OF : 200 66 SF OL - 1 SERVICE STATION C 157 OF : 150 EXIT DOOR 18" REQUIRED 34 1/4" PROVIDED OL - 89 OF : 0.2 75 74 EXIT DOOR 15" REQUIRED 37 1/4" PROVIDED OL - 74 OF : 0.2 114 EXIT DOOR 23" REQUIRED 68 1/2" PROVIDED OL - 114 OF : 0.2 125 116 170 169 EXIT DOOR 27" REQUIRED 71 5/8" PROVIDED OL - 135 OF : 0.2 EXIT DOOR 8" REQUIRED 34 1/4" PROVIDED OL - 36 OF : 0.2 EXIT STAIR 12" REQUIRED OL - 38 OF : 0.3 44" PROVIDED 14 20 26 1 EXIT DOOR 3" REQUIRED 34 1/4" PROVIDED OL - 13 OF : 0.2 EXIT STAIR 4" REQUIRED OL - 13 OF : 0.3 36" PROVIDED 6 135 114 223 EXIT DOOR 68" REQUIRED 71 5/8" PROVIDED OL - 337 OF : 0.2 24 24 EXIT DOOR 59" REQUIRED 68 1/2" PROVIDED OL - 194 OF : 0.3 120 121 EXIT STAIR 9" REQUIRED OL - 29 OF : 0.3 37" PROVIDED 36 3 11 37 55 SF OL - 1 F&B OFFICE D 118 OF : 150 115 E X I T S E P A R A T I O N : M A X D I A G O N A L D I S T A N C E : 1 0 1 '- 6 " 1 0 1 '- 6 " EXIT SEPA RATIO N: 42'-4" 4 EXIT DOOR 23" REQUIRED 34 1/4" PROVIDED OL - 115 OF : 0.2 EXIT DOOR 11" REQUIRED 68 1/2" PROVIDED OL - 52 OF : 0.2 1 EXIT STAIR 27" REQUIRED OL - 88 OF : 0.3 48" PROVIDED EXIT STAIR 11" REQUIRED OL - 36 OF : 0.3 46" PROVIDED G0.52A 1 NOTE: SEE 1/G0.52A FOR COURTYARD EGRESS ANALYSIS EXIT DOOR 15" REQUIRED 42" PROVIDED OL - 75 OF : 0.2 19 14 15 20 20 48 526 SF OL - 3 FUTURE JAPANESE RESTAURANT KITCHEN C 165 OF : 200 194 26 3 E X I T S E P A R A T I O N : M A X D I A G O N A L D I S T A N C E : 6 7 '-1 1 " 6 7 '-1 1 "EX I T S E P A R A T I O N : 41 ' -7" 414 SF OL - 28 FUTURE JAPANESE RESTAURANT (V.I.P. ROOM) C 166 OF : 15 EXIT DOOR 5" REQUIRED 36 3/4" PROVIDED OL - 24 OF : 0.2 EXIT DOOR 5" REQUIRED 35 1/2" PROVIDED OL - 24 OF : 0.2 NON-RATED WALL 1-HOUR FIRE PROTECTED WALL 1-HOUR RATED WALL 2-HOUR RATED WALL 2-HOUR FIRE PROTECTED WALL 3-HOUR RATED WALL 4-HOUR RATED WALL CONCRETE WALL CONCRETE MASONRY UNIT WALL WALL TYPES 1. EVERY ASSEMBLY AREA SHALL HAVE THE OCCUPANT LOAD POSTED IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT OF THE ROOM (CBC 1004.9). SEE G0.38 FOR TYPICAL SIGNAGE MOUNTING REQUIREMENTS AND TEXT SIZING. SHEET NOTES 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 7/ 3 0 / 2 0 2 4 3 : 3 3 : 5 1 P M G0.52 BLDG. C & D EXITING - LEVEL1 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. OCCUPANCY SCHEDULE - BLDG C & D LEVEL 1 NUMBER NAME AREA OCCUPANT FACTOR OCCUPANT LOAD BLDG. C & D LEVEL 1 C 101 QQ C.3 ACC. 505 SF 200 3 C 102 QQ C.3 461 SF 200 3 C 103 KING C.1 426 SF 200 3 C 104 KING C.1 424 SF 200 3 C 105 QQ C.1 416 SF 200 3 C 106 QQ C.1 412 SF 200 3 C 107 KING C.1 420 SF 200 3 C 108 KING C.1 417 SF 200 3 C 109 KING C.1 421 SF 200 3 C 110 KING C.1 417 SF 200 3 C 111 QQ C.1 415 SF 200 3 C 112 QQ C.1 410 SF 200 3 C 113 ELEC. 358 SF 300 2 C 114 KING C.1 418 SF 200 3 C 141 LUGG./BIKE STORAGE 69 SF 300 1 C 142 I.T. ROOM 69 SF 300 1 C 143 OFFICE 101 SF 150 1 C 144 OFFICE 111 SF 150 1 C 145 ADMIN 239 SF 150 2 C 146 FRONT DESK 354 SF 150 3 C 147 EXECUTIVE LOUNGE 771 SF 15 52 C 149 LOBBY 1,475 SF 15 99 C 150 BAR LOUNGE 1,387 SF 15 93 C 151 BAR 229 SF 150 2 C 152 BOH 406 SF 150 3 N SECTION 1009 ACCESSIBLE MEANS OF EGRESS 1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY ACCESSIBLE MEANS OF EGRESS IN AT LEAST THE SAME NUMBER AS REQUIRED BY SECTIONS 1006.2 OR 1006.3. IN ADDITION TO THE REQUIREMENTS OF THIS CHAPTER, MEANS OF EGRESS, WHICH PROVIDE ACCESS TO, OR EGRESS FROM, BUILDINGS FOR PERSONS WITH DISABILI-TIES, SHALL ALSO COMPLY WITH THE REQUIREMENTS OF CHAPTER 11A OR 11B AS APPLICABLE. EXCEPTIONS: 1. ACCESSIBLE MEANS OF EGRESS ARE NOT REQUIRED TO BE PROVIDED IN EXISTING BUILDINGS. 2. ONE ACCESSIBLE MEANS OF EGRESS IS REQUIRED FROM AN ACCESSIBLE MEZZANINE LEVEL IN ACCORDANCE WITH SECTION 1009.3, 1009.4 OR 1009.5, AND CHAPTER 11A OR 11B, AS APPLICABLE. 3. IN ASSEMBLY AREAS WITH RAMPED AISLES OR STEPPED AISLES, ONE ACCESSIBLE MEANS OF EGRESS IS PERMITTED WHERE THE COMMON PATH OF EGRESS TRAVEL IS ACCESSI-BLE AND MEETS THE REQUIREMENTS IN SECTION 1029.8, AND CHAPTER 11A OR 11B, AS APPLICABLE. 1009.2 CONTINUITY AND COMPONENTS. EACH REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE CONTINUOUS TO A PUBLIC WAY AND SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS: 1. ACCESSIBLE ROUTES COMPLYING WITH CHAPTER 11A, SECTIONS 1110A.1 AND 1120A, OR CHAPTER 11B, SECTIONS 11B-206 AND 11B-402, AS APPLICABLE. 2. INTERIOR EXIT STAIRWAYS COMPLYING WITH SECTIONS 1009.3 AND 1023, AND CHAPTER 11A, SECTION 1123A, OR CHAPTER 11B, SECTIONS 11B-210 AND 11B-504, APPLICABLE. 3. EXIT ACCESS STAIRWAYS COMPLYING WITH SECTIONS 1009.3 AND 1019.3 OR 1019.4, CHAPTER 11A, SECTION 1123A, OR CHAPTER 11B, SECTIONS 11B-210 AND 11B-504, AS APPLICABLE. 4. EXTERIOR EXIT STAIRWAYS COMPLYING WITH SECTIONS 1009.3 AND 1027 AND CHAPTER 11A, SECTION 1115A, OR CHAPTER 11B, SECTIONS 11B-210 AND 11B-504, AS APPLICABLE AND SERVING LEVELS OTHER THAN THE LEVEL OF EXIT DISCHARGE. 5. ELEVATORS COMPLYING WITH SECTION 1009.4, AND CHAPTER 11A, SECTION 1124A, OR CHAPTER 11B, SECTIONS 11B-206.6 AND 11B-407, AS APPLICABLE. 6. PLATFORM LIFTS COMPLYING WITH SECTION 1009.5 AND CHAPTER 11A,SECTION 1124A, OR CHAPTER 11B, SECTIONS 11B-206.7, 11B-207.2 AND 11B-410 AS APPLICABLE. 7. HORIZONTAL EXITS COMPLYING WITH SECTION 1026. 8. RAMPS COMPLYING WITH SECTION 1012, AND CHAPTER 11A, SECTIONS 1114A AND 1122A, OR CHAPTER 11B, 11B-405, AS APPLICABLE. 9. AREAS OF REFUGE COMPLYING WITH SECTION 1009.6. 10. EXTERIOR AREAS FOR ASSISTED RESCUE COMPLYING WITH SECTION 1009.7 SERVING EXITS AT THE LEVEL OF EXIT DISCHARGE. 1009.2.1 ELEVATORS REQUIRED. IN BUILDINGS WHERE A REQUIRED ACCESSIBLE FLOOR IS FOUR OR MORE STORIES ABOVE OR BELOW A LEVEL OF EXIT DISCHARGE, NOT LESS THAN ONE REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE AN ELEVATOR COMPLYING WITH SECTION 1009.4. EXCEPTIONS: 1. IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE ELEVATOR SHALL NOT BE REQUIRED ON FLOORS PROVIDED WITH A HORIZONTAL EXIT AND LOCATED AT OR ABOVE THE LEVELS OF EXIT DISCHARGE. 2. IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE ELEVATOR SHALL NOT BE REQUIRED ON FLOORS PROVIDED WITH A RAMP CONFORMING TO THE PROVISIONS OF SECTION 1012. 1009.3 STAIRWAYS. IN ORDER TO BE CONSIDERED PART OF AN ACCESSIBLE MEANS OF EGRESS, A STAIRWAY BETWEEN STORIES SHALL HAVE A CLEAR WIDTH OF 48 INCHES (1219 MM) MINIMUM BETWEEN HANDRAILS AND SHALL EITHER INCORPORATE AN AREA OF REFUGE WITHIN AN ENLARGED FLOOR-LEVEL LANDING OR SHALL BE ACCESSED FROM AN AREA OF REFUGE COMPLYING WITH SECTION 1009.6. EXIT ACCESS STAIRWAYS THAT CONNECT LEVELS IN THE SAME STORY ARE NOT PERMITTED AS PART OF AN ACCESSIBLE MEANS OF EGRESS. [DSA-AC & HCD 1-AC] IN ADDITION, EXIT STAIRWAYS SHALL COMPLY WITH CHAPTER 11A, SECTIONS 1115A AND 1123A, OR CHAPTER 11B, SECTIONS 11B-210 AND 11B-504, AS APPLICABLE. EXCEPTIONS: 1. EXIT ACCESS STAIRWAYS PROVIDING MEANS OF EGRESS FROM MEZZANINES ARE PERMITTED AS PART OF AN ACCESSIBLE MEANS OF EGRESS. 2. THE CLEAR WIDTH OF 48 INCHES (1219 MM) BETWEEN HANDRAILS IS NOT REQUIRED IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. 3. THE CLEAR WIDTH OF 48 INCHES (1219 MM) BETWEEN HANDRAILS IS NOT REQUIRED FOR STAIRWAYS ACCESSED FROM A REFUGE AREA IN CONJUNCTION WITH A HORIZONTAL EXIT. 4. AREAS OF REFUGE ARE NOT REQUIRED AT EXIT ACCESS STAIR-WAYS WHERE TWO-WAY COMMUNICATION IS PROVIDED AT THE ELEVATOR LANDING IN ACCORDANCE WITH SECTION 1009.8. 5. AREAS OF REFUGE ARE NOT REQUIRED AT STAIRWAYS IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. 6. AREAS OF REFUGE ARE NOT REQUIRED AT STAIRWAYS SERVING OPEN PARKING GARAGES. 7. AREAS OF REFUGE ARE NOT REQUIRED FOR SMOKE-PROTECTED ASSEMBLY SEATING AREAS COMPLYING WITH SECTION 1029.6.2. 8. AREAS OF REFUGE ARE NOT REQUIRED AT STAIRWAYS IN GROUP R-2 OCCUPANCIES. 9. AREAS OF REFUGE ARE NOT REQUIRED FOR STAIRWAYS ACCESSED FROM A REFUGE AREA IN CONJUNCTION WITH A HORIZONTAL EXIT. 1009.4 ELEVATORS. IN ORDER TO BE CONSIDERED PART OF AN ACCESSIBLE MEANS OF EGRESS, AN ELEVATOR SHALL COMPLY WITH THE EMERGENCY OPERATION AND SIGNALING DEVICE REQUIREMENTS OF CALIFORNIA CODE OF REGULATIONS, TITLE 8, DIVISION 1, CHAPTER 4, SUBCHAPTER 6, ELEVATOR SAFETY ORDERS. STANDBY POWER SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 27 AND SECTION 3003. THE ELEVATOR SHALL BE ACCESSED FROM AN AREA OF REFUGE COMPLYING WITH SECTION 1009.6. EXCEPTIONS: 1. AREAS OF REFUGE ARE NOT REQUIRED AT THE ELEVATOR IN OPEN PARKING GARAGES. 2. AREAS OF REFUGE ARE NOT REQUIRED IN BUILDINGS AND FACILITIES EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 3. AREAS OF REFUGE ARE NOT REQUIRED AT ELEVATORS NOT REQUIRED TO BE LOCATED IN A SHAFT IN ACCORDANCE WITH SECTION 712. 4. AREAS OF REFUGE ARE NOT REQUIRED AT ELEVATORS SERVING SMOKE-PROTECTED ASSEMBLY SEATING AREAS COMPLYING WITH SECTION 1029.6.2. 5. AREAS OF REFUGE ARE NOT REQUIRED FOR ELEVATORS ACCESSED FROM A REFUGE AREA IN CONJUNCTION WITH A HORIZONTAL EXIT. SCALE: 1/16" = 1'-0"G0 . 5 22BLDG. C & D EXITING PLAN - LEVEL 1 OCCUPANCY SCHEDULE - BLDG C & D LEVEL 1 NUMBER NAME AREA OCCUPANT FACTOR OCCUPANT LOAD C 154 KITCHEN 1,028 SF 200 6 C 157 SERVICE STATION 66 SF 150 1 C 158 BOARD ROOM 215 SF 15 15 C 159 MEETING ROOM 597 SF 15 40 C 161 RESTAURANT DINING (THE OVALO) 2,054 SF 15 137 C 162 V.I.P DINING 2 205 SF 15 14 C 163 V.I.P DINING 1 281 SF 15 19 C 164 FUTURE JAPANESE RESTAURANT 974 SF 15 65 C 165 FUTURE JAPANESE RESTAURANT KITCHEN 526 SF 200 3 C 166 FUTURE JAPANESE RESTAURANT (V.I.P. ROOM) 414 SF 15 28 D 005 ELEC. 349 SF 300 2 D 005A MDF RM 107 SF 300 1 D 006 RISER RM. 88 SF 300 1 D 102 FITNESS CENTER 1,068 SF 50 22 D 104 KITCHEN 617 SF 200 4 D 107 DRY STORAGE 146 SF 300 1 D 112 BANQUET STORAGE 26 SF 300 1 D 113 PREFUNCTION 1,436 SF 15 96 D 114 BANQUET ROOM #1 3,672 SF 15 245 D 115 BANQUET ROOM #2 3,443 SF 15 230 D 117 STAGING 375 SF 200 2 D 118 F&B OFFICE 55 SF 150 1 D 120 OUTDOOR LOUNGE 2,333 SF 15 156 D 123 POOL DECK 1,942 SF 15 130 D 124 POOL 740 SF 50 15 D 126 COURTYARD 3,271 SF 15 219 D 127 WARMING KITCHEN/ SERVING SETUP 264 SF 200 2 D 129 HALL 743 SF 200 4 D 132 DOMESTIC WATER PUMP ROOM 117 SF 200 1 TOTAL 1760 NO.DATE ISSUES & REVISIONS 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) 07.29.24 BULLETIN 9 XX.XX.24 BULLETIN Z (NOT SHOWN) 09/16/2024 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T FP EDISONUTILITIES 1" : 12"DN 1" : 12"DN GM SLPB HUNTINGTON DR. SLOPE SLOPE DN UPDN DN ROOM NUMBER AREA OCCUPANT LOAD FACTOR PER CBC 2019 TABLE 1004.5 OCCUPANT LOAD ACCUMULATED LOAD AND TRAVEL DIRECTION EGRESS PATH OF TRAVEL EXIT STAIR OL - ### OF : ### ##" REQUIRED ##" PROVIDED EXIT DOOR OL - ### OF : ### ##" REQUIRED ##" PROVIDED CAPACITY FACTOR PER CBC 2019 SECTION 1005.3.2 REQUIRED WIDTH DOOR LOAD PROVIDED WIDTH ### LEGEND CAPACITY FACTOR PER CBC 2019 SECTION 1005.3.1 REQUIRED WIDTH STAIR LOAD PROVIDED WIDTH ROOM NAME 101 150 SF OF : ### OL - ### NON-RATED WALL 1-HOUR FIRE PROTECTED WALL 1-HOUR RATED WALL 2-HOUR RATED WALL 2-HOUR FIRE PROTECTED WALL 3-HOUR RATED WALL 4-HOUR RATED WALL CONCRETE WALL CONCRETE MASONRY UNIT WALL WALL TYPES 1. EVERY ASSEMBLY AREA SHALL HAVE THE OCCUPANT LOAD POSTED IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT OF THE ROOM (CBC 1004.9). SEE G0.38 FOR TYPICAL SIGNAGE MOUNTING REQUIREMENTS AND TEXT SIZING. SHEET NOTES 125 117 114 170 169 EXIT SEPA RATIO N: 42'-4" EGRESS COURT 94" REQ'D WIDTH 96" PROVIDED 11' - 2 1/2" COURTYARD 3271 SF OF: 15 OL: 219 EXIT STAIR OL : 468 OF : 0.3 141" REQ'D 96" STAIR + 48" RAMP PROVIDED EXIT STAIR OL : 467 OF : 0.3 140" REQ'D 96" STAIR + 48" RAMP PROVIDED EGRESS COURT 467 468 E X I T S E P A R A T I O N : M A X D I A G O N A L D I S T A N C E : 1 0 6 ' - 7 " 1 0 6 ' - 7 " EXIT SEPARATION:139'-0" 135 114 223 24 48 194 15 20 20 19 14 4 6 24 SCALE: 1/16" = 1'-0"G0 . 5 2 A1COURTYARD EGRESS ANALYSIS 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 8/ 1 / 2 0 2 4 4 : 5 4 : 1 4 P M G0.52A BLDG. C & D EXITING - COURTYARD ANALYSIS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. N SECTION 1009 ACCESSIBLE MEANS OF EGRESS 1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED. ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH THIS SECTION. ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONE ACCESSIBLE MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS ARE REQUIRED BY SECTION 1006.2 OR 1006.3 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE SHALL BE SERVED BY ACCESSIBLE MEANS OF EGRESS IN AT LEAST THE SAME NUMBER AS REQUIRED BY SECTIONS 1006.2 OR 1006.3. IN ADDITION TO THE REQUIREMENTS OF THIS CHAPTER, MEANS OF EGRESS, WHICH PROVIDE ACCESS TO, OR EGRESS FROM, BUILDINGS FOR PERSONS WITH DISABILI-TIES, SHALL ALSO COMPLY WITH THE REQUIREMENTS OF CHAPTER 11A OR 11B AS APPLICABLE. EXCEPTIONS: 1. ACCESSIBLE MEANS OF EGRESS ARE NOT REQUIRED TO BE PROVIDED IN EXISTING BUILDINGS. 2. ONE ACCESSIBLE MEANS OF EGRESS IS REQUIRED FROM AN ACCESSIBLE MEZZANINE LEVEL IN ACCORDANCE WITH SECTION 1009.3, 1009.4 OR 1009.5, AND CHAPTER 11A OR 11B, AS APPLICABLE. 3. IN ASSEMBLY AREAS WITH RAMPED AISLES OR STEPPED AISLES, ONE ACCESSIBLE MEANS OF EGRESS IS PERMITTED WHERE THE COMMON PATH OF EGRESS TRAVEL IS ACCESSI-BLE AND MEETS THE REQUIREMENTS IN SECTION 1029.8, AND CHAPTER 11A OR 11B, AS APPLICABLE. 1009.2 CONTINUITY AND COMPONENTS. EACH REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE CONTINUOUS TO A PUBLIC WAY AND SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING COMPONENTS: 1. ACCESSIBLE ROUTES COMPLYING WITH CHAPTER 11A, SECTIONS 1110A.1 AND 1120A, OR CHAPTER 11B, SECTIONS 11B-206 AND 11B-402, AS APPLICABLE. 2. INTERIOR EXIT STAIRWAYS COMPLYING WITH SECTIONS 1009.3 AND 1023, AND CHAPTER 11A, SECTION 1123A, OR CHAPTER 11B, SECTIONS 11B-210 AND 11B-504, APPLICABLE. 3. EXIT ACCESS STAIRWAYS COMPLYING WITH SECTIONS 1009.3 AND 1019.3 OR 1019.4, CHAPTER 11A, SECTION 1123A, OR CHAPTER 11B, SECTIONS 11B-210 AND 11B-504, AS APPLICABLE. 4. EXTERIOR EXIT STAIRWAYS COMPLYING WITH SECTIONS 1009.3 AND 1027 AND CHAPTER 11A, SECTION 1115A, OR CHAPTER 11B, SECTIONS 11B-210 AND 11B-504, AS APPLICABLE AND SERVING LEVELS OTHER THAN THE LEVEL OF EXIT DISCHARGE. 5. ELEVATORS COMPLYING WITH SECTION 1009.4, AND CHAPTER 11A, SECTION 1124A, OR CHAPTER 11B, SECTIONS 11B-206.6 AND 11B-407, AS APPLICABLE. 6. PLATFORM LIFTS COMPLYING WITH SECTION 1009.5 AND CHAPTER 11A,SECTION 1124A, OR CHAPTER 11B, SECTIONS 11B-206.7, 11B-207.2 AND 11B-410 AS APPLICABLE. 7. HORIZONTAL EXITS COMPLYING WITH SECTION 1026. 8. RAMPS COMPLYING WITH SECTION 1012, AND CHAPTER 11A, SECTIONS 1114A AND 1122A, OR CHAPTER 11B, 11B-405, AS APPLICABLE. 9. AREAS OF REFUGE COMPLYING WITH SECTION 1009.6. 10. EXTERIOR AREAS FOR ASSISTED RESCUE COMPLYING WITH SECTION 1009.7 SERVING EXITS AT THE LEVEL OF EXIT DISCHARGE. 1009.2.1 ELEVATORS REQUIRED. IN BUILDINGS WHERE A REQUIRED ACCESSIBLE FLOOR IS FOUR OR MORE STORIES ABOVE OR BELOW A LEVEL OF EXIT DISCHARGE, NOT LESS THAN ONE REQUIRED ACCESSIBLE MEANS OF EGRESS SHALL BE AN ELEVATOR COMPLYING WITH SECTION 1009.4. EXCEPTIONS: 1. IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE ELEVATOR SHALL NOT BE REQUIRED ON FLOORS PROVIDED WITH A HORIZONTAL EXIT AND LOCATED AT OR ABOVE THE LEVELS OF EXIT DISCHARGE. 2. IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2, THE ELEVATOR SHALL NOT BE REQUIRED ON FLOORS PROVIDED WITH A RAMP CONFORMING TO THE PROVISIONS OF SECTION 1012. 1009.3 STAIRWAYS. IN ORDER TO BE CONSIDERED PART OF AN ACCESSIBLE MEANS OF EGRESS, A STAIRWAY BETWEEN STORIES SHALL HAVE A CLEAR WIDTH OF 48 INCHES (1219 MM) MINIMUM BETWEEN HANDRAILS AND SHALL EITHER INCORPORATE AN AREA OF REFUGE WITHIN AN ENLARGED FLOOR-LEVEL LANDING OR SHALL BE ACCESSED FROM AN AREA OF REFUGE COMPLYING WITH SECTION 1009.6. EXIT ACCESS STAIRWAYS THAT CONNECT LEVELS IN THE SAME STORY ARE NOT PERMITTED AS PART OF AN ACCESSIBLE MEANS OF EGRESS. [DSA-AC & HCD 1-AC] IN ADDITION, EXIT STAIRWAYS SHALL COMPLY WITH CHAPTER 11A, SECTIONS 1115A AND 1123A, OR CHAPTER 11B, SECTIONS 11B-210 AND 11B-504, AS APPLICABLE. EXCEPTIONS: 1. EXIT ACCESS STAIRWAYS PROVIDING MEANS OF EGRESS FROM MEZZANINES ARE PERMITTED AS PART OF AN ACCESSIBLE MEANS OF EGRESS. 2. THE CLEAR WIDTH OF 48 INCHES (1219 MM) BETWEEN HANDRAILS IS NOT REQUIRED IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. 3. THE CLEAR WIDTH OF 48 INCHES (1219 MM) BETWEEN HANDRAILS IS NOT REQUIRED FOR STAIRWAYS ACCESSED FROM A REFUGE AREA IN CONJUNCTION WITH A HORIZONTAL EXIT. 4. AREAS OF REFUGE ARE NOT REQUIRED AT EXIT ACCESS STAIR-WAYS WHERE TWO-WAY COMMUNICATION IS PROVIDED AT THE ELEVATOR LANDING IN ACCORDANCE WITH SECTION 1009.8. 5. AREAS OF REFUGE ARE NOT REQUIRED AT STAIRWAYS IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. 6. AREAS OF REFUGE ARE NOT REQUIRED AT STAIRWAYS SERVING OPEN PARKING GARAGES. 7. AREAS OF REFUGE ARE NOT REQUIRED FOR SMOKE-PROTECTED ASSEMBLY SEATING AREAS COMPLYING WITH SECTION 1029.6.2. 8. AREAS OF REFUGE ARE NOT REQUIRED AT STAIRWAYS IN GROUP R-2 OCCUPANCIES. 9. AREAS OF REFUGE ARE NOT REQUIRED FOR STAIRWAYS ACCESSED FROM A REFUGE AREA IN CONJUNCTION WITH A HORIZONTAL EXIT. 1009.4 ELEVATORS. IN ORDER TO BE CONSIDERED PART OF AN ACCESSIBLE MEANS OF EGRESS, AN ELEVATOR SHALL COMPLY WITH THE EMERGENCY OPERATION AND SIGNALING DEVICE REQUIREMENTS OF CALIFORNIA CODE OF REGULATIONS, TITLE 8, DIVISION 1, CHAPTER 4, SUBCHAPTER 6, ELEVATOR SAFETY ORDERS. STANDBY POWER SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 27 AND SECTION 3003. THE ELEVATOR SHALL BE ACCESSED FROM AN AREA OF REFUGE COMPLYING WITH SECTION 1009.6. EXCEPTIONS: 1. AREAS OF REFUGE ARE NOT REQUIRED AT THE ELEVATOR IN OPEN PARKING GARAGES. 2. AREAS OF REFUGE ARE NOT REQUIRED IN BUILDINGS AND FACILITIES EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 3. AREAS OF REFUGE ARE NOT REQUIRED AT ELEVATORS NOT REQUIRED TO BE LOCATED IN A SHAFT IN ACCORDANCE WITH SECTION 712. 4. AREAS OF REFUGE ARE NOT REQUIRED AT ELEVATORS SERVING SMOKE-PROTECTED ASSEMBLY SEATING AREAS COMPLYING WITH SECTION 1029.6.2. 5. AREAS OF REFUGE ARE NOT REQUIRED FOR ELEVATORS ACCESSED FROM A REFUGE AREA IN CONJUNCTION WITH A HORIZONTAL EXIT. NO.DATE ISSUES & REVISIONS 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) 07.29.24 BULLETIN 9 09/16/2024 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 0 8 A M G3.a GENERAL NOTES HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT GENERAL NOTES: 1.ALL WORK SHALL CONFORM TO REQUIREMENTS OF CALIFORNIA FIRE CODE, STATE BUILDING CODE, TITLE 24, PART 9, AND ALL OTHER APPLICABLE CODES, AS ADOPTED BY THE CITY OF ARCADIA AND ALL OTHER GOVERNING AUTHORITIES HAVING JURISDICTION. 2.ALL REQUIRED PERMITS SHALL BE OBTAINED FROM THE FIRE DEPARTMENT BEFORE THE BUILDING IS OCCUPIED. 3.PROVIDE AN AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT. SPRINKLER SYSTEM PLANS TO BE SUBMITTED TO ARCHITECT, DEPARTMENT OF BUILDING SAFETY AND PLUMBING DIVISION, AND LOS ANGELES FIRE DEPARTMENT FOR APPROVAL PRIOR TO INSTALLATION. THE AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE DESIGNED ON ACCORDANCE WITH NFPA 13. CFC 903 4.PROVIDE AN APPROVED MANUAL/AUTOMATIC FIRE ALARM SYSTEM IN ACCORDANCE WITH CFC 907.2.8. PLANS TO BE SUBMITTED TO THE FIRE DEPARTMENT FOR APPROVAL PRIOR TO INSTALLATION. 5.ALL EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE ENERGIZED FROM SEPARATE CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES WIRING SYSTEM. IN THE EVENT OF POWER FAILURE, THE SYSTEM SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM. ALL LIGHTED EXIT SIGNS SHALL HAVE STROKE BLOCK LETTERS ON A CONTRASTING BACKGROUND IN ACCORDANCE WITH LOCAL CODES. 6.ALL EXIT WAYS SHALL BE ILLUMINATED BY AN APPROVED EMERGENCY LIGHTING SYSTEM DESIGNED TO OPERATE WHEN THE BUILDING POWER SOURCE IS INTERRUPTED. EMERGENCY LIGHTING SYSTEM SHALL GIVE A MINIMUM VALUE OF ONE-FOOT CANDLE AT FLOOR LEVEL. 7.EXIT PATH LIGHTING SHALL BE PROVIDED FOR STAIRWAYS, HALLWAYS, EXIT PASSAGEWAYS, AND EGRESS TO A PUBLIC WAY ANY TIME THE BUILDING IS OCCUPIES. 8.PROVIDE PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR OR AS REQUIRED BY THE FIRE DEPARTMENT OR FIELD INSPECTOR; ALSO DURING CONSTRUCTION. PORTABLE FIRE EXTINGUISHER IN ELECTRICAL ROOMS, MECHANICAL ROOMS, OR PARKING SHALL NOT BE RATED LESS THAN 10 BC. 9.PORTABLE FIRE EXTINGUISHERS SHALL BE HANGED NO MORE THAN 5 FEET HIGH IN LOCATIONS DESIGNATED BY THE LOCAL FIRE DEPARTMENT. THEY SHALL BE HOUSED IN A CABINET. THEY SHALL BE IN A NORMAL PART OF TRAVEL AND SIGNS SHALL BE CONSPICUOUS. LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECT PRIOR TO INSTALLATION. 10.FIRE APPARATUS ACCESS ROADS AND WATER SUPPLIES FOR FIRE PROTECTION, SHALL BE INSTALLED AND MADE SERVICEABLE PRIOR TO AND DURING TIME OF CONSTRUCTION. CFC 501.4 11.STREET OR ROAD SIGNS -TEMPORARY SIGNS SHALL BE INSTALLED AT EACH STREET INTERSECTION WHEN CONSTRUCTION OF NEW ROADWAYS ALLOWS PASSAGE BY VEHICLES. SIGNS SHALL BE OF AN APPROVED SIZE, WEATHER RESISTANT AND BE MAINTAINED UNTIL REPLACE BY PERMANENT SIGNS. CFC 505.2 12.PROVIDE BUILDING ADDRESS NUMBERS, VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY PER FHPS P-00-6 13.FIRE APPARATUS ACCESS ROADS SHALL BE DESIGNED AND MAINTAINED TO SUPPORT THE IMPOSED LOADS OF FIRE APPARATUS AND SHALL BE SURFACED SO AS TO PROVIDE ALL WEATHER DRIVING CAPABILITIES. CFC 503.2.3 14.CLEAR SPACE AROUND HYDRANTS -A 3 FT CLEAR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF FIRE HYDRANTS, EXCEPT AS OTHERWISE REQUIRED OR APPROVED. CFC 507.5.5 15.PHYSICAL PROTECTION -WHERE FIRE HYDRANTS ARE SUBJECT TO IMPACT BY A MOTOR VEHICLE, GUARD POSTS OR OTHER APPROVED MEANS SHALL COMPLY WITH SECTION 312. CFC 507.5.6 16.DEAD ENDS -DEAD END FIRE APPARATUS ACCESS ROADS IN EXCESS OF 150 FEET IN LENGTH SHALL BE PROVIDED WITH AN APPROVED AREA FOR TURNING AROUND FIRE APPARATUS. CFC 503.2.5 17.SECURITY GATES -WHERE SECURITY GATES ARE INSTALLED, THEY SHALL HAVE AN APPROVED MEANS OF EMERGENCY OPERATION. THE SECURITY GATES AND EMERGENCY OPERATION SHALL BE MAINTAINED OPERATIONAL AT ALL TIMES. ELECTRIC GATE OPERATORS, WHERE PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL 325. GATES INTENDED FOR AUTOMATIC OPERATION SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED TO COMPLY WITH THE REQUIREMENTS OF ASTM F 2200. 18.VEGETATION SHALL BE SELECTED AND MAINTAINED IN SUCH A MANNER AS TO ALLOW IMMEDIATE ACCESS TO ALL HYDRANTS, VALVES, FIRE DEPARTMENT CONNECTIONS, PULL STATIONS, EXTINGUISHERS, SPRINKLER RISERS, ALARM CONTROL PANELS, RESCUE WINDOWS AND OTHER DEVICES OR AREAS USED FOR FIREFIGHTING PURPOSED. VEGETATION OR BUILDING FEATURES SHALL NOT OBSTRUCT ADDRESS NUMBERS OR INHIBIT THE FUNCTIONING OF ALARM BELLS, HORNS OR STROBES. 19.APPROVED DOCUMENTS -CONSTRUCTION DOCUMENTS APPROVED BY THE FIRE CODE OFFICIAL ARE APPROVED WITH THE INTENT THAT SUCH CONSTRUCTION DOCUMENTS COMPLY IN ALL RESPECTS WITH CFC 105.4.4. REVIEW AND APPROVAL BY THE FIRE CODE OFFICIAL SHALL NOT RELIEVE THE APPLICANT OF THE RESPONSIBILITY OF COMPLIANCE WITH THIS CODE. 20.LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS SHALL BE IN ACCORDANCE WITH CFC 906 AND CALIFORNIA CODE REGULATIONS (CCR), TITLE 19. 21.DURING CONSTRUCTION, AT LEAST ONE EXTINGUISHER SHALL BE PROVIDED ON EACH FLOOR LEVEL AT EACH STAIRWAY, IN ALL STORAGE AND CONSTRUCTION SHEDS, IN LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED OR USED, AND WHERE OTHER SPECIAL HAZARDS ARE PRESENT PER CFC 3315.1 716) 22.IN BUILDINGS THAT REQUIRE STANDPIPES, STANDPIPES SHALL BE PROVIDED DURING CONSTRUCTION WHEN THE HEIGHT REACHES 40 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICULAR ACCESS. A FIRE DEPARTMENT CONNECTION SHALL BE NO MORE THAN 100 FEET FROM AVAILABLE FIRE DEPARTMENT VEHICULAR ACCESS ROADWAYS. CFC 3310, 3313 23.BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION, OR DEMOLITION SHALL CONFORM TO CFC CHAPTER 33. WELDING, CUTTING, AND OTHER HOT WORK SHALL BE IN CONFORMANCE WITH CFC CHAPTER 35. 24.WALL, FLOOR AND CEILING FINISHES AND MATERIALS SHALL NOT EXCEED THE INTERIOR FINISH CLASSIFICATIONS IN CBC TABLE 803.9 AND SHALL MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF THE CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIVISION 1. DECORATION MATERIALS SHALL BE PROPERLY TREATED BY A PRODUCT OR PROCESS APPROVED BY THE STATE FIRE MARSHAL WITH APPROPRIATE DOCUMENTATION PROVIDED TO THE CITY OF ARCADIA. 25.DUMPSTERS AND TRASH CONTAINERS EXCEEDING 1.5 CUBIC YARDS SHALL NOT BE STORED IN BUILDINGS OR PLACED WITHIN 5 FEET OF COMBUSTIBLE WALLS, OPENINGS OR COMBUSTIBLE ROOF EAVE LINES UNLESS PROTECTED BY AN APPROVED SPRINKLER SYSTEM OR LOCATED IN A TYPE I OR IIA STRUCTURE SEPARATED BY 10 FEET FROM OTHER STRUCTURES. CONTAINERS LARGER THAN 1 CUBIC YARD SHALL BE OF NON-OR LIMITED-COMBUSTIBLE MATERIALS OR SIMILARLY PROTECTED OR SEPARATED. CFC 304.3 26.EXITS, EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS, FIRE EXTINGUISHER LOCATIONS, AND STANDPIPE CONNECTIONS SHALL NOT BE CONCEALED BY CURTAINS, MIRRORS, OR OTHER DECORATIVE MATERIAL. 27.OPEN FLAMES, FIRE, AND BURNING ON ALL PREMISES IS PROHIBITED EXCEPT AS SPECIFICALLY PERMITTED BY THE CITY OF ARCADIA AND CFC 308. 28.THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF ALL OBSTRUCTIONS AT ALL TIMES. NO STORAGE IS PERMITTED IN ANY EGRESS PATHS. 29.PROVIDE "EMERGENCY RESPONDER RADIO COVERAGE" IN ACCORDANCE WITH CFC 510 30.PROVIDE ULTRA-LOW FLUSH WATER CLOSET FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTEDFOR LOW WATER CONSUMPTION. 31 SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH , NONABSORBENT SURFACE TO HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET (SECTION 1210.2.3). USE OF WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE AS STATED IN SECTION 2509.3 32.WATER HEATERS MUST BE STRAPPED TO A WALL (SEC. 507.3, UPC) 33.THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES, WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 34.AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170, 158) (INCLUDES COMMERCIAL ADDITIONS AND TI WORK OVER $10,000.) SEPARATE PLUMBING PERMIT IS REQUIRED. GENERAL NOTES (CONT.): 35.PROVIDE ULTRA-LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 36.SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET (SECTION 1210.2.3). USE OF WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE AS STATED IN SECTION 2509.3 37.WATER HEATERS MUST BE STRAPPED TO A WALL (SEC. 507.3, UPC) 38.UNIT SKYLIGHTS SHALL BE LABELED BY AN APPROVED LABELLING AGENCY. SUCH LABEL SHALL STATE THE APPROVED LABELLING AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE GRADE RATING (RESEARCH REPORT NOT REQUIRED), 2405.5 39.A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. 40.REGISTERED DEPUTY GRADING INSPECTOR IS REQUIRED ON GRADING AND FOUNDATION EARTHWORK WHERE (SITE EXCEEDS 60,000 SF.) (CUT OR FILL SLOPES EXCEED 2:1) (CUTS EXCEED 40 FT. IN HEIGHT AND WITHIN 20 FT. OF A PROPERTY LINE) (FOUNDATION EXCAVATION BELOW A 1:1 PLANE FROM PROPERTY LINE) (PROJECTS INVOLVE UNUSUAL HAZARDS) (SHORING WORK INCLUDING SLOT-CUTS) 41. BUILDINGS SHALL HAVE APPROVED RADIO COVERAGE FOR EMERGENCY RESPONSES. SEE LOS ANGELES FIRE CODE SECTION 510 FOR MORE DETAILS. 42. THIS BUILDING SHALL BE PROVIDED WITH A MANUAL ALARM SYSTEM WITH THE CAPABILITY TO SUPPORT VISIBLE ALARM NOTIFICATION APPLIANCES IN ACCORDANCE WITH NFPA 72. (907.2.9, 907.5.2.3.3, 907.5.2.3.4) 43.THE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, & INTERIOR DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH THE INSTALLATION OF STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, OR FINISH WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE CONSULTANT DRAWINGS THAT WOULD CAUSE AN AWKWARD INSTALLATION, IT SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL EXPENSE TO THE OWNERS OR ARCHITECT. 44.SPECIFICATIONS, BOUND SEPARATELY, ARE A PART OF THESE CONTRACT DOCUMENTS. 45.IN NO CASE SHALL DRAWINGS BE SCALED FOR DIMENSIONS. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD BEFORE PROCEEDING WITH SUBSEQUENT WORK. THE ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCIES FOR CLARIFICATION PRIOR TO PROCEEDING WITH SAID WORK. 46.THE SYMBOLS AND ABBREVIATIONS USED ON THESE DRAWINGS ARE CONSIDERED TO BE CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEM OR THEIR EXACT MEANING HE SHALL NOTIFY THE ARCHITECT FOR CLARIFICATION. 47.NO SUBSTITUTIONS SHALL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL. REQUESTS FOR SUBSTITUTIONS SHALL BE IN CONFORMANCE WITH THE SPECIFICATIONS. 48.SHOP DRAWINGS SHALL BE SUBMITTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE SPECIFICATIONS. THE GENERAL CONTRACTOR SHALL SUBMIT A SCHEDULE OF SUBMITTALS AND SAMPLES FOR THE ARCHITECT'S APPROVAL. 49.GENERAL CONTRACTOR SHALL COORDINATE SITE PLUMBING, DRAINAGE, ELECTRICAL, TELEPHONE AND EXISTING UTILITIES WORK TO PROVIDE A COMPLETE OPERATING SYSTEM. 50.ALL REQUIRED WORK AND REPAIR OF DAMAGES ON AND OFF PUBLIC PROPERTY (SIDEWALKS, DRIVEWAYS,CURBS, STREETS, ETC.) SHALL BE DONE ACCORDING TO THE GOVERNING REGULATIONS. MATCH AND PATCH OF THIS WORK IS TO BE CONSISTENT WITH REGULATIONS AND EXISTING ADJOINING CONDITIONS. 51.ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE OR MASONRY UNITS, CENTERLINE OF STEEL BEAMS OR COLUMNS, UNLESS OTHERWISE NOTED. 52.FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE, UNLESS OTHERWISE NOTED. 53.CEILING HEIGHT DIMENSIONS ARE TO FINISHED SURFACES, UNLESS OTHERWISE NOTED. 54.OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACE WILL BE FLUSH. 55.ALL FRAMING MEMBERS SHALL BE SO ARRANGED AND SPACED AS TO PERMIT INSTALLATION OF PIPE, CONDUITS AND DUCTWORK WITH A MINIMUM OF CUTTING. CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACES, BACK-UP PLATES AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL WALL MOUNTED OR SUSPENDED STAIR RAILINGS, CASEWORK, TOILET ROOM ACCESSORIES, MECHANICAL, ELECTRICAL, PLUMBING, OR MISCELLANEOUS EQUIPMENT. 56.GYPSUM BOARD AT EXTERIOR WALLS, WHERE SHOWN, SHALL EXTEND TO THE UNDERSIDE OF DECK. 57.DUCTS PENETRATING STUD WALLS OR SHAFT WALLS SHALL BE PROVIDED WITH NECESSARY FRAMES, BRACING AND SMOKE AND ACOUSTICAL SEALANT AROUND THE OPENING. 58.ALL EQUIPMENT RECESSED INTO FIRE RATED WALLS SHALL BE PROVIDED WITH BACKING BEHIND TO MAINTAIN THE FIRE RATING OF THAT WALL. 59.CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT PADS AND BASES, AS WELL AS POWER AND WATER OR DRAIN INSTALLATIONS WITH EQUIPMENT MANUFACTURERS BEFORE PROCEEDING WITH THE WORK. CHANGES TO ACCOMMODATE FIELD CONDITIONS OR SUBSTITUTIONS SHALL BE MADE WITHOUT ADDITIONAL COST TO OWNER OR ARCHITECT. 60.CONTACT BETWEEN DISSIMILAR METALS SHALL BE PROTECTED AS DESCRIBED IN THE SPECIFICATIONS. 61.CONTRACTOR TO VERIFY ALL CONCRETE/MASONRY OPENINGS IN THE FIELD PRIOR TO THE FABRICATION OF DOORS AND FRAMES. 62.ALL DOOR SIZES SHOWN ON THE DOOR SCHEDULE ARE OPENING SIZES. ALLOWANCE FOR THRESHOLDS, ETC. SHALL BE MADE PRIOR TO DOOR FABRICATION AND INSTALLATION. ALL DOORS AND FRAMES SHALL BE REINFORCED WHERE REQUIRED FOR CLOSERS, STOPS, HARDWARE, ETC. SEE SPECIFICATIONS FOR FURTHER INFORMATION. 63.DOORS IN RATED WALLS SHALL CONSIST OF SELF CLOSING, SELF LATCHING ASSEMBLIES WITH SMOKE AND DRAFT SEALS AT HEAD AND JAMB. DOOR ASSEMBLY RATINGS SHALL BE AS INDICATED ON THE DOOR SCHEDULE. HOLD OPEN DEVICES ON RATED ASSEMBLIES SHALL BE MAGNETICALLY OPERATED AND ACTIVATED BY SMOKE DETECTORS TO ALLOW THE DOORS TO AUTOMATICALLY CLOSE. PROVIDE COORDINATORS FOR PAIRS OF DOORS TO ALLOW FOR PROPER CLOSING SEQUENCE. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO BUILDING OFFICIAL. GENERAL NOTES (CONT.): 67.DOOR OPENINGS IN GYPSUM BOARD PARTITIONS NOT DIMENSIONED ARE TO BE LOCATED IN THE CENTER OF THE SPACE OR WITHIN 5" OF ADJOINING PARTITIONS. MOST DOOR OPENINGS IN CONCRETE BLOCK WALLS ARE TO BE LOCATED TO FIT WITHIN THE BLOCK MODULE UNLESS OTHERWISE NOTED. 68.ALL EXTERIOR DOORS SHALL BE WEATHER-STRIPPED AT JAMBS, HEAD, AND SILL. 69.ROOF DRAINAGE SHALL NOT FLOW OVER PUBLIC PROPERTY, OR ADJACENT PROPERTIES. 70.ONE HOUR CORRIDORS AND ANY ENCLOSED CEILINGS WITHIN THEM SHALL NOT BE USED AS AN INTEGRAL PART OF THE DUCT SYSTEM, CBC 1018.5 71.NON-RATED DROP CEILINGS IN RATED CORRIDORS IF USED MUST BE NONCOMBUSTIBLE CONSTRUCTION. 72.PROVIDE BLOCKING AND BACKING FOR TOILET ACCESSORIES, MIRRORS, MILLWORK, FF&E AND ACCESSORIES AND ANY AND ALL LOCATIONS WHERE SURFACE MOUNTED MATERIALS AND EQUIPMENTS MAY REQUIRE BACKING FOR MOUNTING PURPOSES 73.PROVIDE 3/4" PLYWOOD ON ALL (4) WALLS OF PBX/COMPUTER ROOM 74.AN OCCUPANCY WITH AN OCCUPANT COUNT >50. REFER TO CBC SECTION 1008.1.8.3, ITEM 2 FOR EXCEPTION. 75.ELECTRICAL ROOMS WITH EQUIPMENT RATED 1,200 AMPERES OR MORE AND OVER 6' WIDE THAT CONTAIN OVER CURRENT DEVICES, SWITCHING DEVICES OR CONTROL DEVICES WITH EXIT ACCESS DOORS SHALL BE EQUIPPED WITH PANIC HARDWARE AND DORRS SHALL SWING IN THE DIRECTION OF EGRESS. 76.PENETRATIONS IN FIRE PARTITION BY DUCTS AND AIR TRANSFER OPENINGS SHALL COMPLY WITH CBC SECTION 716. 77.DUCT PENETRATING THE CEILING MEMBRANE OF THE FIRE RATED FLOOR/CEILING ASSEMBLY SHALL BE ENCLOSED IN A SHAFT IN ACCORDANCE WITH SECTION 713 OR SHALL HAVE A LISTED CEILING RADIATION DAMPER INSTALLED AT THE CEILING LINE. CBC 717.6.2 78.JOINTS AND OPENINGS, ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY [SEC. 4.406.1] 79. OUTDOOR LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED TO COMPLY WITH ALL OF THE FOLLOWING: a. THE MINIMUM REQUIREMENTS IN CALIFORNIA ENERGY CODE FOR LIGHTING ZONE 1-4 b. BACKLIGHT, UPLIGHT AND GLARE (BUG) RATINGS AS DEFINED IN IESNA TM-15-11 c. ALLOWABLE BUG RATINGS NOT EXCEEDING THOSE SHOWN IN ON TABLE 5.106.8 80.STAIRWAY REQUIREMENTS: A. A MAXIMUM 7" RISE AND MINIMUM 11" RUN (TREAD). B. HANDGRIP PORTION OF HANDRAIL SHALL NOT BE LESS THAN 1-1/4" NOR MORE THAN 2" CROSS-SECTION DIAM. DIMENSION HAVING A SMOOTH SURFACE WITH NO SHARP CORNERS. C. A HANDRAIL HEIGHT 34" TO 38" ABOVE THE NOSING, 1-1/2" CLEARANCE TO THE WALL, 1-1/2" MAX. WIDTH AND ENDS RETURNED TO THE WALL. THE OPEN SIDE SHALL HAVE INTERMEDIATE RAILS OR BALLUSTERS SPACED 4" MAX 81.EACH LIGHT OF SAFETY GLAZING MATERIAL INSTALLED IN HAZARDOUS LOCATIONS SHALL BE IDENTIFIED BY A PERMANENT LABEL THAT SPECIFIES THE LABELER, AND STATES THAT SAFETY GLAZING MATERIAL HAS BEEN UTILIZED IN SUCH INSTALLATIONS. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING A. GLAZING IN INGRESS AND EGRESS DOORS EXCEPT JALOUSIES. B. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SWINGING DOORS OTHER THAN WARDROBE DOORS. C. GLAZING IN ALL UNFRAMED SWINGING DOORS. 82.GLAZING IN FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF GLAZING IS WITHIN A 24" ARC OF VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" ABOVE THE WALKING SURFACE SHALL BE SAFETY GLAZING CBC 2406.3 83.GLAZING AND OPENINGS IN FIRE BARRIERS SHALL BE LIMITED TO 25% OF THE WALL AREA, NO LARGER THAN 156 SQUARE FEET CBC 706.8 84.WALKS AND SIDEWALKS SHALL BE 48" MINIMUM IN WIDTH. 85.WHEN CHANGES IN LEVEL NOT EXCEEDING 1/2" OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2, EXCEPT THAT LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. 86.ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE EXCEEDING 1/2" SHALL COMPLY WITH THE REQUIREMENTS FOR CURB RAMPS. 87.WALK AND SIDEWALK SURFACES SHALL BE SLIP-RESISTANT AS FOLLOWS: A. SURFACES WITH A SLOPE OF 6% GRADIENT SHALL BE AT LEAST A SLIP-RESISTANT AS THAT DESCRIBED AS A MEDIUM SALTED FINISH. B. SURFACES WITH A SLOPE OF 6% OR GREATER GRADIENT SHALL BE SLIP-RESISTANT. 88.WALK AND SIDEWALK SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4" PER FOOT. 89.LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE 90.MAXIMUM EFFORT TO OPERATE EXTERIOR AND INTERIOR DOORS SHALL NOT EXCEED 5 POUNDS, WITH SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAYBE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. 91.ALL TREAD SURFACES SHALL BE SLIP RESISTANT. WEATHER EXPOSED STAIRS AND THEIR APPROACHES SHALL BE DESIGNED SO THAT WATER WILL NOT ACCUMULATE ON WALKING SURFACES. TREADS SHALL HAVE SMOOTH, ROUNDED, OR CHAMFERED EXPOSED EDGES, AND NO ABRUPT EDGES AT THE NOSING (LOWER FRONT EDGE.) 92.ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH DISABILITIES AND AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL SHALL BE IDENTIFIED WITH A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE TO PERSONS ALONG APPROACHING PEDESTRIAL WAYS. 93.WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES OF A BUILDING OR SITE, RAISED LETTERS SHALL BE PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISHED FLOOR TO THE CENTER LINE OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN WITHIN THE SWING OF THE DOOR. 94.THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48" ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE, OR SIDEWALK. 95.CONTROLS FOR WATER CLOSET FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS. 96.WHEN STANDARD COMPARTMENT DOORS ARE USED, WITH A MINIMUM 9" CLEARANCE FOR FOOTRESTS UNDERNEITH AND A SELF-CLOSING DEVICE, CLEARANCE AT THE STRIKE EDGE, AS SPECIFIED. 97.THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH. THE LATCH SHALL BE FLIP-OVER STYLE, SLIDING, OR OTHER HARDWARE NOT REQUIRING THE USER TO GRASP OR TWIST. 98.ALL EQUIPMENT ANCHORAGE, VIBRATION ISOLATION, AND SEISMIC RESTRAINT SYSTEMS FOR ALL EQUIPMENT SHALL BE ENGINEERED, FABRICATED, SUPPLIED AND INSTALLED BY THE APPROPRIATE SUB CONTRACTOR. PROVIDE CALCULATIONS PREPARED BY A LICENSED STRUCTURAL ENGINEER. SUBMIT DETAILS AND CALCULATIONS TO ARCHITECT AND COUNTY OFFICIALS. GENERAL NOTES (CONT.): 99.ALL WELDING SHALL BE DONE BY A CERTIFIED WELDER AND IN ACCORDANCE WITH CITY OF RIVERSIDE REQUIREMENTS. 100.NO MATERIALS SHALL BE STORED ON PUBLIC PROPERTY UNLESS AN ENCROACHMENT PERMIT IS FIRST OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS. 101.THE BUILDING INSPECTOR SHALL BE NOTIFIED PRIOR TO THE START OF CONSTRUCTION. 102.TEMPORARY TOILET FACILITIES SHALL BE PROVIDED DURING CONSTRUCTION. 103.ALL RUBBISH AND DEBRIS RESULTING FROM DEMOLITION OR NEW WORK SHALL BE DISPOSED OF OFF SITE AND SHALL NOT BE ALLOWED TO ACCUMULATE. 104.DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. 105.ALL HARDWARE IN RATED DOORS SHALL BEAR AN "UL" LABEL. 106.ALL ELEVATOR SYSTEMS TO BE ENGINEERED, FABRICATED, SUPPLIED AND INSTALLED BY ELEVATOR SUBCONTRACTOR AND COMPLY WITH CBC CHAPETR 30 AND 1124A. PROVIDE CALCULATIONS PREPARED BY A LICENSED STRUCTURAL ENGINEER. SUBMIT DETAILS AND CALCULATIONS TO ARCHITECT AND CITY OFFICIALS. 107.ALL STEEL STAIRS IF USED TO BE ENGINEERED, FABRICATED, SUPPLIED AND INSTALLED BY STEEL STAIRS SUBCONTRACTOR. PROVIDE CALCULATIONS PREPARED BY A LICENSED STRUCTURAL ENGINEER. SUBMIT DETAILS AND CALCULATIONS TO ARCHITECT AND COUNTY OFFICIALS. 108.AN AUTOMATIC SPRINKLER SYSTEM SHALL BE INSTALLED AT THE TOP OF RUBBISH AND LINEN CHUTES AND IN THEIR TERMINAL ROOMS. CHUTES SHALL HAVE ADDITIONAL SPRINKLER HEADS INSTALLED AT ALTERNATE FLOORS AND AT THE LOWEST INTAKE (LAFC 903.2.11.2) 109.CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS IN THE INDIVIDULE UNIT. REQUIRED CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPED WITH A BATTERY BACKUP (CBC 915.4.2/4) 110. PROVIDE EMERGENCY RESPONDER RADIO COVERAGE IN ACCORDANCE WITH LAFC 510 (CBC 916.1) 111. MEANS OF EGRESS SERVING A ROOM OR SPACE SHALL BE ILLUMINATED AT ALL TIMES THAT THE ROOM OR SPACE IS OCCUPIED. THE ILLUMINATION LEVEL SHALL NOT BE <1 FOOTCANDLE AT THE WALKING SURFACE. (CBC 1008.2) 112. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS FOR A DURATION OF NOT <90 MIN. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 FOOTCANDLE AND A MIN. AT ANY POINT OF .1 FOOTCANDLE. (CBC 1008.3-5) A. AISLES B. CORRIDORS C. EXIT ACCESS STAIRWAYS AND RAMPS D. INTERIOR AND EXTERIOR EXIT STAIRWAYS AND RAMPS E. EXIT PASSAGEWAYS F. VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE USED FOR EXIT DISCHARGE. G. ELECTRICAL EQUIPMENT ROOMS. H. FIRE COMMAND CENTERS. I. FIRE PUMP ROOMS. J. GENERATOR ROOMS. K. PUBLIC RESTROOMS > 300 SF 113.PROVIDE TWO-WAY COMMUNICATION AT THE LANDING SERVING EACH ELEVATOR OR BANK ELEVATORS ABOVE OR BELOW THE LEVEL OF EXIT DISCHARGE (CBC 1009.8) 114.EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED (CBC 1013.3) 115.TACTILE EXIT SIGNS SHALL BE REQUIRED AT THE FOLLOWING LOCATIONS: (CBC 1013.4) 1. “EXIT”SIGN AT EACH GRADE-LEVEL EXTERIOR DOOR. 2. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE: A. “EXIT STAIR DOWN” B. “EXIT RAMP DOWN” C. “EXIT STAIR UP” D. “EXIT RAMP UP” 3. “EXIT ROUTE”AT EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY. 4. “EXIT ROUTE”AT EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY 5. “TO EXIT”AT EACH EXIT DOOR THROUGH A HORIZONTAL EXIT. 6. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. (CBC 1013.5) 7. THE FACE OF AN EXIT SIGN ILLUMINATED FROM AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF ≥5 FOOTCANDLES. (CBC 1013.6.2) 8. IN CASE OF PRIMARY POWER LOSS, THE SIGN ILLUMINATION MEANS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM FOR A DURATION OF NOT <90 MINUTES. (CBC 1013.6.3) 9. PROVIDE A SIGN AT EACH FLOOR LANDING IN AN INTERIOR EXIT STAIRWAY AND RAMP CONNECTING >3 STORIES DESIGNATING THE FLOOR LEVEL, THE TERMINUS OF THE TOP AND BOTTOM AND THE IDENTIFICATION OF THE STAIRWAY OR RAMP. THE SIGNAGE SHALL ALSO STATE THE STORY OF, AND THE DIRECTION TO, THE EXIT DISCHARGE AND THE AVAILABILITY OF ROOF ACCESS FOR THE FIRE DEPARTMENT. THE SIGN SHALL BE LOCATED 5’ABOVE THE FLOOR LANDING (CBC 1023.9) 116.SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS IN THE INDIVIDULE UNIT. REQUIRED SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. (LAFC 907.2.11.5-6) 117.CARBON MONOXIDE DETECTION SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: (LAFC 915.1.1) A. DWELLING UNITS: I.OUTSIDE OF EACH SEPARATE SLEEPING AREA. II.EVERY OCCUPIABLE LEVEL OF A DWELLING UNIT. III.BEDROOMS WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN OR ITS ATTACHED BATHROOM. B.SLEEPING UNITS. 118.GROUP R-1 FIRE ALARM SYSTEMS AND SMOKE ALARM: (LAFC 907.2.8) A. PROVIDE A MANUAL FIRE ALARM SYSTEM. B. PROVIDE AN AUTOMATIC SMOKE DETECTION SYSTEM THROUGHOUT ALL INTERIOR CORRIDORS SERVING SLEEPING UNITS. C. PROVIDE SINGLE AND MULTIPLE STATION SMOKE ALARMS: a. IN SLEEPING AREAS. b. IN EVERY ROOM IN THE PATH OF EGRESS FROM THE SLEEPING AREA TO THE DOOR LEADING FROM THE UNIT. c. IN EACH STORY WITHIN THE SLEEPING UNIT. 119.PROVIDE 3 ACCELEROGRAPHS AS REQUIRED BY SECTION 1613.10.2 OF CODE. SEE P/BC 2017-048 120.EMERGENCY AND STANDBY POWER SYSTEMS SHALL BE DESIGNED TO PROVIDE REQUIRED POWER FOR 6-HR MIN. UNLESS SPECIFIED OTHERWISE. ( LAFC 604.1.4) 2022 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 0 9 A M G3.b GENERAL NOTES HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SPECIAL HAZARDS: 1.INTERIOR FINISHED AND COMBUSTIBLE DECORATIVE MATERIALS SHALL COMPLY WITH CFC 801. 2.NO HAZARDOUS CHEMICALS WILL BE STORED IN THE BUILDING THAT WILL EXCEED THE QUANTITIES LISTED IN CBC TABLES 307.1(1) AND 307.2(2) 3.THE STORAGE, USE AND DISPENSING OF HAZARDOUS MATERIALS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE QUANTITIES AS SET FORTH IN TABLES 307.1 (1) AND (2) OF THE CBC. 4.THE STORAGE, USE AND DISPENSING OF HAZARDOUS MATERIALS, AS DEFINED BY THE FIRE CODE, SHALL COMPLY WITH CFC CHAPTER 27. 5.PROVIDE COLLISION BARRIERS ADEQUATE TO PROTECT CONTROL METERS, REGULATORS, AND PIPING FOR HAZARDOUS MATERIALS THAT ARE EXPOSED TO VEHICULAR DAMAGE. 6.PARKING SPACES SHALL NOT OBSTRUCT REQUIRED EXITS. 7.CONSPICUOUSLY MARK GAS SHUT-OFF VALVE. 8.MEANS OF EGRESS MUST HAVE CONTINUOUS, UNOBSTRUCTED, AND UNDIMINISHED PATH TO A PUBLIC WAY. 14.MEANS OF EGRESS SHALL BE ILLUMINATED AT A MINIMUM INTENSITY OF 1 FOOR-CANDLE AT THE FLOOR LEVEL. 15.MEANS OF EGRESS ILLUMINATED SHALL BE PROVIDED FROM AN EMERGENCY POWER SYSTEM. BUILDING ENVELOPE 1. A FIRE RETARDANT ROOF COVERING IS REQUIRED . CLASS "A" ROOF COVERING IS REQUIRED FOR ALL BUILDINGS LOCATED IN A VERY HIGH FIRE HAZARD SEVENTY ZONE. 2. PROVIDE ANTI-GRAFFITI FINISH AT THE FIRST 9 FEET, MEASURED FROM GRADE, AT EXTERIOR WALLS AND DOORS. (6306) 3. EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS LOCATIONS SHALL BE IDENTIFIED BY A MANUFACTURE'S DESIGNATION SPECIFYING WHO APPLIED THE DESIGNATION, THE MANUFACTURER OR INSTALLER AND THE SAFETY GLAZING STANDARD. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSED OF SAFETY GLAZING. GLAZING IN: SECTION 2406 a. SWING DOORS. b. FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BI-FOLD CLOSET DOOR ASSEMBLIES. c. STORM DOORS. d. UNFRAMED SWING DOORS. e. DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS f. FIXED OR OPERABLE PANELS ADJACENT TO A DOOR WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN 24 INCHES (610 MM) ARC OF EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES (1525 MM) ABOVE THE WALKING SURFACE. g. FIXED OR OPERABLE PANEL, OTHER THAN DESCRIBED IN ITEMS E AND F, WHICH MEETS ALL OF THE FOLLOWING CONDITIONS i. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.84 m2) ii. EXPOSED BOTTOM EDGE LESS THAN 18 INCHES (457 mm) ABOVE THE FLOOR. iii. EXPOSED TOP EDGE GREATER THAN 36 INCHES 9914 mm) ABOVE FLOOR. iv. ONE OR MORE WALKING SURFACE WITHIN 36 INCHES (914 mm) HORIZONTALLY OF THE PLANE OF THE GLAZING. 4.THE MIN ROOF COVERINGS INSTALLED ON BUILDINGS SHALL COMPLY WITH T1505.1 (CBC 1505.1) EXIT REQUIREMENTS: 1. A. ALL LEGAL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, OR SHALL HAVE LEGAL SIGNS POSTED READING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE MOUNTED BOLTS ARE PROHIBITED. B. CONTRACTOR SHALL PROVIDE TEMPORARY EXIT SIGNS TO ASSURE A MEANS OF EGRESS DURING CONSTRUCTION. C. DOORS EQUIPPED WITH PANIC HARDWARE SHALL BE OPENABLE WITH A MAXIMUM FORCE OF 15 LBS. APPLIED IN THE DIRECTION OF EGRESS TO THE BAR. D. AN APPROVED SIGN THAT COMPLIES WITH SECTION 11B-703 SHALL BE LOCATED AT EACH FLOOR LEVEL LANDING IN ALL ENCLOSED STAIRWAYS. THE SIGN SHALL INDICATE FLOOR LEVEL, TERMINUS OF THE TOP AND BOTTOM OF THE STAIRWAY, INDICATE WHETHER THERE IS ROOF ACCESS, AND THE IDENTIFICATION OF THE STAIRWAY. SIGN SHALL USE RAISED ARABIC NUMERALS & BRAILLE SYMBOLS. SIGN TO BE 12" X 12" MOUNTED 60" AFF. IN A POSITION WHICH IS REDILY VISIBLE WHEN THE DOOR IS IN THE OPEN OR CLOSED POSITION OR, THE SIGN SHALL BE LOCATED APP. 5' ABOVE THE FLOOR LANDING IMMEDIATELY ADJACENT TO THE DOOR ON THE STRIKE SIDE. E. ELECTRICALLY LOCKED DOORS AT STAIR ENCLOSURES OR ELEVATOR LOBBIES SHALL UNLOCK UPON ACTIVATION OF FIRE ALARM SYSTEM OR LOSS OF BUILDING POWER. 2. ALL EXIT DOORS SERVING AN OCCUPANT LOAD OF 10 OR MORE, ALONG WITH PATH OF EXIT TRAVEL ANYWHERE IN A MEANS OF EGRESS SYSTEM. A. ALL REQUIRED EXIT DOORS SHALL BE NOT LESS THAN 3 FT. WIDE, 6'-8" HIGH, SHALL HAVE A CLEAR EXIT WAY WIDTH OF NOT LESS THAN 32" AND SHALL BE CAPABLE OF OPENING 90 DEGREES. THE MAXIMUM DOOR LEAF WIDTH IS 4 FEET WHEN SERVING AN OCCUPANT LOAD OF 10 OR MORE. 3. THE PATH OF EXIT TRAVEL TO AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF CBC SECTION 1011. EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF APPROACH. EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS. NO POINT SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN. 4. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. WHEN THE FACE OF AN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54 (1X)) FROM EITHER OF TWO ELECTRIC LAMPS. INTERNALLY ILLUMINATED SIGNS SHALL PROVIDE EQUIVALENT LUMINANCE AND BE LISTED FOR THE PURPOSE. 5. THE EXIT SIGNS SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM PROVIDED FROM THE ON-SITE EMERGENCY GENERATOR SET, AND THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE ELECTRICAL CODE. 6. FLOOR-LEVEL EXIT SIGN REQUIREMENTS [CBC 1013]: A. INTERNALLY OR EXTERNALLY ILLUMINATED PHOTOLUMINESCENT OR SELF-LUMINOUS B. BOTTOM OF THE SIGN SHALL NOT BE LESS THAN 6" OR MORE THAN 8" ABOVE THE FLOOR LEVEL C. SIGN SHALL INDICATE THE PATH OF TRAVEL D. SIGN SHALL BE ON EXIT AND EXIT ACCESS DOORS OR ADJACENT TO THE DOOR WITH THE CLOSEST EDGE OF THE SIGN WITHIN 4 INCHES OF THE DOOR FRAME. 7.EXITS SHALL DISCHARGE DIRECTLY TO THE EXTERIOR OF THE BUILDING. (CBC 1028.2) 8.EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREA OR GROUP H OCCUPANCY. 9.EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE AN APPROVED TYPE. 10.PANIC HARDWARE SHALL BE PROVIDED ON EXIT DOORS HANDLING AN OCCUPANCY CAPACITY OF 50 OR MORE PERSONS, FROM ANY GROUP A, OCCUPANCY. ONLY PANIC HARDWARE APPROVED AND LISTED BY THE STATE FIRE MARSHAL SHALL BE INSTALLED. 11.AISLES LEADING TO REQUIRED CORRIDORS AND EXITS SHALL HAVE A MINIMUM WIDTH OF 44". 12.FIRE ASSEMBLIES INSTALLED ACROSS EXIT CORRIDORS SHALL BE AUTOMATIC-CLOSING FIRE ASSEMBLIES ACTIVATED BY A SMOKE DETECTOR. ALL HOLD-OPEN DEVICES SHALL BE LISTED FOR THE PURPOSE. FIRE-RESISTANCE RATED CONSTRUCTION 1.SMOKE AND FIRE DAMPERS MUST BE INSTALLED IN THE FOLLOWING LOCATIONS PER SECTION 717.5 a. DUCT PENETRATIONS OF FIRE WALLS IN ACCORDANCE TO SECTION (717.5.1) b. DUCT PENETRATIONS OF FIRE BARRIERS, EXCEPT EXIT ENCLOSURES AND EXIT PASSAGEWAYS WHERE THEY ARE NOT ALLOWED TO PENETRATE. (717.5.2) c. DUCTS PENETRATING SHAFTS. (717.5.3) d. DUCTS PENETRATING FIRE PARTITIONS AND FIRE RATED CORRIDOR WALLS. SEE EXCEPTION FOR STEEL DUCTS WITH NO OPENINGS INTO CORRIDOR (717.5.4) e. DUCTS PENETRATING SMOKE BARRIERS (717.5.5) f. DUCTS PENETRATING EXTERIOR WALLS (717.5.6) g. DUCTS PENETRATING SMOKE PARTITIONS (717.5.7) h. DUCTS PENETRATING HORIZONTAL ASSEMBLIES (717.6) 2.ELEVATOR LOBBY IS REQUIRED AT EACH FLOOR WHERE AN ELEVATOR ENCLOSURE CONNECTS MORE THAN 2-STORIES. (3006.2) 3.THIS BUILDING FOR TYPE I-A/III-A CONSTRUCTION, PROVIDE: a. CONTINUOUS GYP. BD. BEHIND ALL TUBS IS REQUIRED UNLESS THE WALLS ARE WITHIN THE UNIT AND NON-BEARING. BACK TO BACK TUBS WITH A COMMON PLUMBING WALL ARE IMPRACTICAL IN 1-HOUR BUILDINGS. b. ALL INTERIOR BEARING WALLS SHALL BE CONSTRUCTED WITH FIRE-RESISTIVE CONSTRUCTION PER T-601 ON G0.01. c. NOT USED. d. ALL OPENINGS IN FLOOR/CEILING ARE REQUIRED TO BE ENCLOSED BY A SHAFT HAVING WALL, FLOOR, AND CEILING OF _2_ HOUR FIRE RESISTIVE CONSTRUCTION. (713.1) e. RECESSED CEILING LIGHT FIXTURES MUST BE BOXED AROUND WITH 5/8"TYPE “X”GYP. BD.” TO MAINTAIN THE FIRE RATED CEILING ASSEMBLY. f. CONTINUOUS GYP. BD. IS REQUIRED BEHIND NON-RATED PANELS AND CABINETS, ALL ELECTRICAL SERVICE PANELS, FIRE HOSES AND MEDICINE CABINETS TO MAINTAIN WALL ASSEMBLY FIRE RATING. g. EXHAUST FANS FROM THE BATHROOM MUST ENTER THROUGH THE WALL. DAMPERS ARE REQUIRED IF THE CEILING IS PENETRATED (717.5) h.PLUMBING PENETRATION THROUGH HORIZONTAL OCCUPANCY SEPARATIONS SHALL BE BOXED OUT AND FILLED WITH APPROVED SAFING MATERIAL. i.PENETRATION OF THE FIRE RATED CEILING BY DUCTS FROM THE FAU AND THE STOVE HOOD REQUIRE DAMPERS (USE A DUCTLESS HOOD WHENEVER POSSIBLE). ATTIC UNITS (INCLUDING HEAT PUMPS) REQUIRE DAMPERS AT ALL CEILING PENETRATIONS (711) j.STEEL BEAMS AND COLUMNS SHALL BE INDIVIDUALLY PROTECTED AS REQUIRED PER T-601 ON G0.01 FOR FIRE RATED PROTECTION. (704.3) k. ALL PLUMBING PENETRATIONS THRU WALLS WHICH REQUIRE PROTECTED OPENINGS (FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS) ARE REQUIRED TO BE GALVANIZED OR CAST IRON PIPING. 4.DOOR OPENING INTO ONE HOUR FIRE RESISTIVE CORRIDOR SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP FIRE ASSEMBLY HAVING A MINIMUM 20 MIN. RATING. DOOR AND FRAME SHALL BEAR AN APPROVED LABEL SHOWING THE RATING FOLLOWED BY THE LETTER "S". 5.ELEVATOR VESTIBULE DOORS SHALL BE AUTOMATIC CLOSING BY ACTION OF SMOKE DETECTION. 6.NON-RATED DROP CEILINGS IN RATED CORRIDORS IF USED MUST BE NONCOMBUSTIBLE CONSTRUCTION. 7.THE MAXIMUM AREA OF EXTERIOR WALL OPENINGS SHALL NOT EXCEED THAT ALLOWED IN CBC TABLE 705.8 8.WHEN PROTECTED AND UNPROTECTED OPENINGS OCCUR IN THE EXTERIOR WALL IN ANY STORY, THE TOTAL AREA SHALL COMPLY WITH THE UNITY FORMULA (7-2) IN CBC 705.8.4 9.STRUCTURAL ELEMENTS IN EXTERIOR WALLS REQUIRED TO BE FIRE RESISTIVE CONSTRUCTION SHALL HAVE FIRE RESISTIVE PROTECTION EQUAL TO OR GREATER THAN THAT REQUIRED FOR EXTERIOR BEARING WALL CBC 704.10 10.IN FIRE RESISTIVE EXTERIOR WALL CONSTRUCTION, THE FIRE RESISTIVE CONSTRUCTION SHALL BE MAINTAINED PASSING THRU ATTIC AND OTHER SIMILAR AREAS. 11.PARTYWALLS/FIREWALLS MUST BE STRUCTURALLY INDEPENDENT OF COLLAPSE UNDER FIRE PER CBC 706.2 12.OPENINGS IN FIRE WALL TO COMPLY WITH CBC 706.8 13.FIREWALLS TERMINATING AT EXTERIOR WALLS MUST COMPLY WITH CBC 706.5.1 14.ALL STRUCTURAL ELEMENTS SUPPORTING A FIRE BARRIER SHALL HAVE THE SAME FIRE RESISTIVE RATINGS AS THE REQUIRED OCCUPANCY SEPARATION CBC 707.5.1 15.OPENINGS PROTECTIVE'S IN FIREWALLS MUST COMPLY WITH CBC 715 AND TABLE 715.4 16.PENETRATIONS IN FIRE PARTITION MUST COMPLY WITH CBC 713. 17.JOINTS IN OTHER THAN 2-FAMILY FIRE PARTITIONS MUST COMPLY WITH CBC 714. 18.DUCT PENETRATING FIRE PARTITIONS MUST COMPLY WITH CBC 716 19.A SMOKE BARRIER COMPLYING WITH CBC 711 IS REQUIRED IN ACCORDANCE WITH CBC 407.4 AND 408.6. 20. FIRE DAMPERS SHALL BE PROVIDED WHERE DUCTS PENETRATE FIRE-RATED WALLS OR CEILINGS. 21. BUILDINGS SHALL HAVE APPROVED RADIO COVERAGE FOR EMERGENCY RESPONSES. SEE FIRE CODE SECTION 510 FOR MORE DETAILS. 22. THIS BUILDING SHALL BE PROVIDED WITH A MANUAL ALARM SYSTEM WITH THE CAPABILITY TO SUPPORT VISIBLE ALARM NOTIFICATION APPLIANCES IN ACCORDANCE WITH NFPA 72. (907.2.9, 907.5.2.3.3, 907.5.2.3.4) 23. PENETRATIONS IN A FIRE-RATED WALL SHALL BE PROTECTED BY AN APPROVED FIRE STOP MATERIAL IN ACCORDANCE WITH SECTION 714.3.1. a. STEEL, COPPER OR FERROUS PIPES OR CONDUITS MAY PENETRATE CONCRETE OR MASONRY WALLS WHERE THE PENETRATING ITEM IS A MAXIMUM 6-INCH DIAMETER AND THE AREA OF THE OPENING THROUGH THE WALL DOES NOT EXCEED 144 SQUARE INCHES. b. MEMBRANE PENETRATIONS OF MAXIMUM 2-HR. FIRE-RESISTANCE RATED WALL AND PARTITIONS BY STEEL ELECTRICAL OUTLET BOXES NOT EXCEEDING 16 SQUARE INCHES ARE PERMITTED PROVIDED OPENINGS DO NOT EXCEED 100 SQUARE INCHES FOR ANY 100 SQUARE FEET OF WALL AREA. OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR PARTITIONS MUST BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES. (714.3.2) WHERE WALLS ARE PENETRATED BY OTHER MATERIALS OR WHERE LARGER OPENINGS ARE REQUIRED THAN PERMITTED IN (B) ABOVE, THEY MUST BE QUALIFIED BY TESTS CONDUCTED IN ACCORDANCE WITH SECTION (714.3.1.1) 24. FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL: A.BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACES. B.BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET (914 MM) MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION; AND C. INCLUDE LETTERING NOT LESS THAN 3 INCH IN HEIGHT WITH A MINIMUM 3/8-INCH STROKE IN CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING: “FIRE AND/OR SMOKE BARRIER--PROTECT ALL OPENINGS”, OR OTHER WORDING. ENERGY REQUIREMENTS: 1.A. THE FOLLOWING NOTES ARE PROVIDED TO LIMIT AIR LEAKAGE AS REQUIRED BY CODE. 1. FIXED WINDOWS SHALL BE SEALED TO LIMIT AIR INFILTRATION. 2. ALL EXTERIOR DOORS SHALL LIMIT AIR LEAKAGE AROUND THEIR PERIMETER WHEN IN A CLOSED POSITION. 3. PROVIDE SEAL OR ASTRAGAL AT HEAD, SILL AND JAMB. B. DOORS MOUNTED ON THE INSIDE OR THE OUTSIDE OR EXTERIOR WALLS SHALL HAVE A MINIMUM OR 1" LAP AT JAMBS. C. MEETING PORTIONS OF SECTIONAL, BI-PARTING, OR DOUBLE DOORS SHALL BE PROVIDED WITH A WEATHER TIGHT ASTRAGAL OR SEAL. D. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF, BETWEEN WALL PANELS AND AT PENETRATIONS OF UTILITIES THROUGH THE ENVELOPE, SHALL BE SEALED, CAULKED, OR WEATHER-STRIPPED TO LIMIT AIR LEAKAGE. E. A "CERTIFICATE OF COMPLIANCE" SIGNED BY THE GENERAL CONTRACTOR SHALL BE GIVEN TO THE BUILDING DEPARTMENT STATING THAT THE WORK HAS BEEN PERFORMED AND MATERIALS INSTALLED ACCORDING TO THE PLANS AND SPECIFICATIONS AFFECTING NON-RESIDENTIAL ENERGY. F. DEMISING WALLS, SEPARATING CONDITIONED SPACE FROM ENCLOSEDUNCONDITIONED SPACE MUST BE INSULATED WITH A MINIMUM OF R-13 INSULATION. 2.AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. 3.WATER HEATER MUST BE STRAPPED TO WALL. 4.IN B, F, M, AND S OCCUPANCIES, PANES OF GLAZING WITH AT LEAST ONE DIMENSION GREATER THAN 5 IN. BUT LESS THAN 48 IN. SHALL BE CONSTRUCTED OF TEMPERED OR APPROVED BURGLARY-RESISTANT MATERIAL OR PROTECTED WITH METAL BARS OR GRILLS. 5.GLAZED OPENINGS WITHIN 40" OF THE DOOR LOCK WHEN THE DOOR IS IN THE CLOSED POSITION, SHALL BE FULLY TEMPERED GLASS OR APPROVED BURGLARY-RESISTANT MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, SCREENS OR GRILLS HAVING A MAXIMUM OPENING OF 2". THE PROVISIONS OF THIS SECTION SHALL NOT APPLY TO VIEW PORTS OR WINDOWS WHICH DO NOT EXCEED 2" IN THEIR GREATEST DIMENSIONS. 6.THE EXIT PASSAGEWAY REQUIRES 1 HOUR CONSTRUCTION FOR WALLS, FLOOR AND CEILING. WALLS SHALL BE WITHOUT OPENINGS EXCEPT FOR REQUIRED EXITS. EXIT OPENINGS THROUGH ENCLOSING WALLS SHALL BE 1HR RATED. 7.IN DETERMINING THE OCCUPANT LOAD, ALL PORTIONS OF A BUILDING SHALL BE PRESUMED TO BE OCCUPIED AT THE TIME EXCEPT FOR ACCESSORY USE AREAS THAT ORDINARILY ARE USED ONLY BY PERSONS WHO OCCUPY MAIN AREA. BARRIER FREE ACCESS REQUIREMENTS:(SEE ALSO SHEETS G0.31, G0.32, & G0.33) A. PLACE A SIGN AT EVERY PUBLIC ENTRANCE AND AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN ACCESSIBLE PATH OF TRAVEL DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SIGNS SHALL INDICATE THE DIRECTION TO ACCESSIBLE FACILITY ENTRANCES AND COMPLY WITH CBC 1110A THRU 1116A.5 B. EACH ENTRY DOOR SHALL BE PROVIDED WITH A 5" SQUARE SYMBOL OF ACCESSIBILITY, MOUNTED ON THE SIDELIGHT ADJACENT TO THE ACCESSIBLE DOOR. C. ALL DOORS WITH ILLUMINATED EXIT SIGNS SHALL ALSO HAVE EXIT SIGNS WITH BRAILLE MOUNTED 60" ABOVE FINISH FLOOR ON THE STRIKE SIDE OF THE DOOR, PER CBC 11B-703.4 D. THE BOTTOM 10" OF ALL DOORS, EXCEPT AUTOMATIC AND SLIDING DOORS, SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE, PER CBC 11B-404.2.10 E. ALL SWINGING DOORS SHALL BE OPERABLE BY A SINGLE EFFORT, PER CBC 11B-404.2.9 F. PROVIDE A MIN. 2" -MAX. 4" WIDE CONTRASTING PAINTED COLOR STRIP ON THE UPPER APPROACH AND LOWEST TREAD OF EACH FLIGHT OF INTERIOR AND EXTERIOR STAIRS. THE STRIP SHALL BE LOCATED PARALLEL TO AND NOT MORE THAN 1" FROM THE NOSING OF TREAD OR LANDING, AND SHALL BE AT LEAST AS SLIP RESISTANT AS THE TREAD OR LANDING. G. IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY AND THE SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS, OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR AREAS, BOUNDARY BETWEEN AREAS SHALL BE DEFINED BY CONTINUOUS DETECTABLE WARNING WHICH IS 36" WIDE, PER CBC 11B-705 H. ABRUPT CHANGES IN LEVEL, EXCEPT BETWEEN A WALK OR SIDEWALK AND AN ADJACENT STREET OR DRIVEWAY, EXCEEDING 4" IN VERTICAL DIMENSION (SUCH AS AT PLANTERS OR FOUNTAINS LOCATED IN OR ADJACENT TO WALKS, SIDEWALKS OR OTHER PEDESTRIAN WAYS) SHALL BE IDENTIFIED BY CURBS PROJECTING AT LEAST 6" IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE TO WARN THE BLIND OF POTENTIAL DROP-OFF, PER CBC 11B-303.5 I. ALL PUBLIC LIGHT SWITCHES, FIRE ALARMS, AND OTHER PUBLIC CONTROL SWITCHES AND DEVICES SHALL BE MOUNTED A MAXIMUM OF 48" TO THE TOP MOST OPERABLE POINT ABOVE THE FINISH FLOOR SURFACE, PER CBC 11B-308 J. CONTRACTOR SHALL REVIEW THE LOCATION AND MOUNTING HEIGHTS OF THE TOILET ROOM ACCESSORIES WITH THE RECOMMENDATIONS OF THE ACCESSORY MANUFACTURER AND BUILDING INSPECTOR PRIOR TO INSTALLATION TO ASSURE CORRECT POSITIONING. K. ALL GRAB BARS SHALL BE MOUNTED 1-1/2" CLEAR OF THE WALL OR PARTITION. L. DRINKING FOUNTAINS SHALL BE MOUNTED SO THAT THE BASIN IS LOCATED PER MANUFACTURERS' RECOMMENDED BARRIER FREE INSTALLATION. DUAL HEIGHT FOUNTAIN REQUIRED. M. ALL EXPOSED WASTE AND HOT WATER PIPING BENEATH LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. N. EACH ELEVATOR ENTRANCE AND CAR SHALL BE EQUIPPED WITH PROVISIONS FOR THE HANDICAPPED AND BLIND IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL ORDINANCES. ALSO SEE THE SPECIFICATIONS. O. PROVIDE SEATS/SPACES FOR PEOPLE USING WHEELCHAIR, AT LEAST ONE PER FUNCTIONAL AREA IN ACCORDANCE WITH CBC 11B-221 AND CBC TABLE 11B-221.2.1.1 P. WHERE DINING SURFACES ARE PROVIDED, AT LEAST 5% OF THE SEATING SPACES AND STANDING SPACES SHALL BE ACCESSIBLE AND SHALL BE DISPERSED THROUGHOUT THE DINING SPACES FROM EACH TYPE OF SEATING IN A FUNCTIONAL AREA, PER CBC 11B-226 Q. WHERE FOOD IS SERVED AT TABLES, A MIN. 30" WIDE SECTION OF TABLETOP, AT 28" MIN -34" MAX. HEIGHT ABOVE FINISH FLOOR, SHALL BE PROVIDED FOR EACH FORWARD APPROACHING WHEELCHAIR SPACE, PER CBC 11B-902 R. PROVIDE 32" WIDE DOORS TO ALL INTERIOR ACCESSIBLE ROOMS FIRE PROTECTION: 1.PROVIDE AUTOMATIC FIRE EXTINGUISHING SYSTEM THROUGHOUT THE BUILDING. 2.SPRINKLER SYSTEM SHALL BE APPROVED BY BUILDING AND SAFETY, FIRE DEPARTMENT MECHANICAL PLAN CHECKS PRIOR TO INSTALLATION. 3.SPRINKLER SYSTEM SHALL BE CALCULATED PER PAMPHLET #13. 4.SPRINKLER SYSTEM SHALL BE MONITORED BY AN APPROVED CENTRAL STATION, REMOTE STATION, OR PROPRIETARY SUPERVISING STATION IN ALL OCCUPANCIES NOT NORMALLY OCCUPIED 24 HOURS A DAY, OR PROVIDE WITH 24 HOUR GUARD SERVICE. CFC 903.4 5.PROVIDE STANDPIPE PER CBC 905 6.PROVIDE SPRINKLERS AT LINEN CHUTE AND TERMINATING ROOM, CBC 903.2.10.2 7. AN AUTOMATIC SPRINKLER SYSTEM IS REQUIRED THROUGHOUT ALL BUILDINGS WITH GROUP "R" FIRE AREA. "THIS BUILDING AND GARAGE MUST BE EQUIPPED WITH AN AUTOMATIC FIRE EXTINGUISHING SYSTEM, COMPLYING WITH (nfpa-13); THE SPRINKLER SYSTEM SHALL BE APPROVED BY PLUMBING DIV. PRIOR TO INSTALLATION. (903.2) 8.PROVIDE AUTOMATIC ALARM SYSTEM FOR THE BUILDING WITH BOTH VISUAL AND AUDIBLE ALARMS ACTIVATED BY THE BOTH IN-ROOM SMOKE DETECTOR AND THE BUILDING FIRE ALARM SYSTEM ON SLEEPING UNITS. (CBC 907.5.2.3.3) 9.PROVIDE EMERGENCY RESPONSE RADIO COVERAGE IN ACCORDANCE WITH SECTION 510 OF THE CALIFORNIA FIRE CODE. (CBC 916.1) 10.COMBINATION SMOKE AND FIRE DAMPERS SHALL BE REQUIRED WHERE A FIRE AND SMOKE BARRIER OR WALL IS REQUIRED CBC 717. 11.ALL FIRE RATED ASSEMBLIES SHALL BE I.C.B.O. OR U.L. APPROVED AND PROVIDED AS INDICATED ON THE APPROVED DRAWINGS. ANY PENETRATIONS AT FIRE RESISTIVE ASSEMBLIES SHALL BE SEALED WITH U.L. APPROVED FIRE STOPPING. SUBMIT MANUFACTURES INSTALLATION INSTRUCTIONS OF FIRE STOPPING TO BUILDING INSPECTOR FOR APPROVAL. 12. PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED: 9SIZE AND DISTRIBUTION SHALL BE IN ACCORDANCE WITH SECTIONS 906.3.1-906.3.4)(CBC 906.3) I. IN GROUP A, E, F, H, I, R-2< R-2.1 OCCUPANCIES II. ON EACH FLOOR OF STRUCTURES UNDER CONSTRUCTION III. WHERE REQUIRED BY THW T906.1. IV. SPECIAL-HAZARD AREAS, WHERE REQUIRED BY THE FIRE CODE OFFICIAL. 13. PROVIDE A BARRIER AT THE LEVEL OF EXIT DISCHARGE TO PREVENT PERSONS FROM CONTINUEING INTO LEVELS BELOW (CBC 1023.8) 14. PROVIDE SINGLE-AND MULTIPLE-STATION SMOKE ALARMS: -IN SLEEPING AREAS -IN EVERY ROOM IN THE PATH OF EGRESS FROM THE SLEEPING AREA TO THE DOOR LEADING FROM THE UNIT. -IN EACH STORY WITHIN THE SLEEPING UNIT. 15. SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS IN THE INDIVIDUAL UNIT. REQUIRED SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. (CBC 907.2.11.5-6) INTERIOR FINISHES 1. INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE 803.13 {CBC 803.13} 2. MATERIAL, OTHER THAN FOAM PLASTICS, USED AS INTERIOR TRIM SHALL HAVE A MIN CLASS "C" FLAME SPREAD AND SMOKE-DEVELOPED INDEX AND SHALL NOT EXCEED 10% OF THE WALL OR CEILING AREA IN WHICH IT IS ATTACHED. {CBC 806.7} 3. CURTAINS, DRAPERIES, FABRIC HANGINGS, AND SIMILAR COMBUSTIBLE DECORATIVE MATERIALS SUSPENDED FROM WALLS OR CEILINGS SHALL NOT EXCEED 10% OF THE WALL OR CEILING AREA TO WHICH SUCH MATERIALS ARE ATTACHED. {CBC 806.2} 4. IN EVERY GROUP A,E, I R-1, R-2, AND R-2.1, ALL DRAPES, HANGINGS, CURTAINS, DROPS, AND ALL OTHER DECORATIVE MATERIAL SHALL BE MADE FROM A NONFLAMABLE MATERIAL OR TREATED AND MAINTAINED IN A FLAME-RETARDANT CONDITION BY MEANS OF A FLAME-RETARDANT SOLUTION OR PROCESS APPROVED BY OSFM, {TITLE 19, DIV 1 3.08} 16.WALL, FLOOR, AND CEILING SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.5 FLAME SPREAD RATINGS OF FINISHES: STAIRWELLS - CLASS A EXIT CORRIDORS & LOBBIES - CLASS B ELSEWHERE - CLASS C INTERIOR ENVIRONMENT 1. PROVIDE STAIRWAY ILLUMINATION. MIN. 1 FOOT-CANDLE AT TREAD RUNS 2. PROVIDE NATURAL LIGHT IN (HABITABLE ROOMS) BY MEANS OF EXTERIOR WALL OPENINGS WITH AN AREA NOT LESS THAN 8% OF FLOOR AREA 91205.2) 3. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION 1205.2 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 10 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (1205.1 AND 1205.3) FIRE PROTECTION (CONTINUED): 17. CARBON MONOXIDE DETECTION SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS (CBC 915.1.1): A. DWELLING UNITS: -OUTSIDE OF EACH SEPARATE SLEEPING AREA -EVERY OCCUPIABLE LEVEL OF A DWELLING UNIT. -BEDROOMS WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN OR ITS ATTACHED BATHROOM. B. SLEEPING UNITS. 18. CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS IN THE INDIVIDUAL UNIT. REQUIRED CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. (CFC 915.4) NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 1 1 A M G3.c GENERAL NOTES HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT GREEN BUILDING 1. OUTDOOR LIGHTING SYSTEMS SHALL BE DESIGNED AND INSTALLED TO COMPLY WITH ALL OF THE FOLLOWING: a. THE MINIMUM REQUIREMENTS IN CALIFORNIA ENERGY CODE FOR LIGHTING ZONE 1-4 b. BACKLIGHT, UPLIGHT AND GLARE (BUG) RATINGS AS DEFINED IN IESNA TM-15-11 c. ALLOWABLE BUG RATINGS NOT EXCEEDING THOSE SHOWN IN ON TABLE (5.106.8) WATER EFFICIENCY AND CONCERVATION 2. FOR BUILDINGS IN EXCESS OF 50,000 SQ. FT. SEPARATE SUBMETERS SHALL BE INSTALLED AS FOLLOWS: a.FOR EACH INDIVIDUAL LEASED, RENTED OR OTHER TENANT SPACE WITHIN THE BUILDING PROJECTED TO CONSUME MORE THAN 100 GAL/DAY. b.WHERE METERS FOR INDIVIDUAL BUILDINGS TENANTS ARE UNFEASIBLE, FOR WATER SUPPLIED TO THE FOLLOWING SUBSYSTEM: i. MAKEUP WATER FOR COOLING TOWERS WHERE FLOW THROUGH IS GREATER THAN 500 GPM. ii. MAKEUP WATER FOR EVAPORATIVE COOLERS GRATER THAN 6GPM. iii. sTEAM AND HOT-WATER BOILERS WITH ENERGY IMPUT MORE THAN 500,000 BTU/H c. FOR EACH BUILDING THAT USES MORE THAN 100 GALLONS PER DAY ON A PARCEL CONTAINING MULTIPLE BUILDINGS (5.303.1.1) 3. SEPARATE SUBMETERS SHALL BE INSTALLED IN ANY BUILDING OR NEW SPACE WITHIN A BUILDING THAT IS PROJECTED TO CONSUME MORE THAN 1,000 GAL/DAY. (5.303.1.2) 4. NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED THA MAXIMUM ALLOWABLE FLOW RATES SPECIFIED IN SECTION (5.303.3) 5. WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEAD, THECOMBINED FLOW RATE OF ALL THE SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PERMINUTE AT 80 psi, OR THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE IN OPERATIONAT A TIME. (5.303.3.3) 6. FOR PROJECTS THAT INCLUDE LANDSCAPE WORK, THE LANDSCAPE CERTIFICATION, FORM GRN 12, SHALL BE COMPLETED PRIOR TO FINAL INSPECTION APPROVAL. (STATE ASSEMBLY BILL No. 1881, 5.304.1) 7. LOCKS SHALL BE INSTALLED ON ALL PUBLICLY ACCESSIBLE EXTERIOR FAUCETS AND HOSE BIBS. (5.304.5) 8. FOR SITES WITH OVER 500 SQUARE FEET OF LANSCAPE AREA, WASTE POPONG SHALL BE ARRANGED TO PERMIT DISCHARGE FROM THE CLOTHES WASHER, BATHTUB, SHOWERS, AND BATHROOM/RESTROOMS WASH BASIN TO BE USED FOR A FUTURE GRAY WATER IRRIGATION SYSTEM. (5.305.1) 9. WATER USED IN THE BUILDING FOR WATER CLOSETS, URINALS, FLOOR DRAINS, AND PROCESS COOLING AND HEATING SHALL COME FROM CITY-RECYCLE WATER IF AVAILABLE FOR USE WITHIN 300 FEET OF THE PROPERTY LINE. (5.305.2) 10. COOLING TOWER SHALL HAVE A MINIMUM OF 6 CYCLES OF CONCENTRATION (BLOWDOWN) OR HAVE A MINIMUM 50% OF MAKEUP WATER SUPPLY TO COOLING TOWERS COME FROM NON-PORTABLE WATER SOURCES. (5.305.3) 11. WHERE GROUNDWATER IS BEING EXTRACTED AND DISCHARGED, A SYSTEM FOR ONSITE REUSE OF THE GROUND WATER SHALL BE DEVELOPED AND CONSTRUCTED IF THE GROUNDWATER WILL NOT BE DISCHARGED TO THE SEWER. (4.305.4) 12. AUTOMAIC LANDSCAPE IRRIGATORS SHALL BE INSTALLED IN SUCH A WAY THAT IT DOESN'T SPRAY ON THE BUILDING. (5,407.2.1) 13. TESTING AND ADJUSTMENT IS REQUIRED FOR ALL NEW INSTALLATION OF ANY OF THE FOLLOWING SYSTEMS: a. RENEWABLE ENERGY SYSTEMS i. DESCRIBE THE TYPE OF SYSTEM (E.G. SOLAR PHOTOVOLTAIC, WIND TUBINES, ETC.) ii. PROVIDE A NARRATIVE OF THE TESTING AND ADJUSTMENT PROCEDURE FOR SYSTEM b. LANDSCAPE IRRIGATION SYSTEM i. DESCRIVE THE TYPES OF IRRIGATORS AND CONTROLLER(S) ii. PROVIDE A NARRATIVE OF THE TESTING AND ADJUSTMENT PROCEDURE FOR THE IRRIGATION SYSTEM, INCLUDING BUT NOT LIMITED TO, PRESSURE TEST, WATER COVERAGE, AND PROPER CONTROLLER FUNCTION. c. WATER REUSE SYSTEMS i. DESCRIBE THE GREYWATER OR RECLAIMED/RECYLED WATER SYSTEM ii. PROVIDE A NARRATIVE OF THE TESTING AND ADJUSTMENT PROCEDURE FOR THE SYSTEM (5.410.4.2, 5.410.4.3) 14. A FINALREPORT FOR THE TESTING AND ADJUSTING OF ALL NEW SYSTEMS SHALL BE COMPLETED AND PROVIDED TO THE FIELD INSPECTOR PRIOR TO FINAL APPROVAL. THIS REPORT SHALL BE SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES. (5.310.4.4) 15. AN OPERATION & SYSTEMS MANUAL, SHALL BE PROVIDED TO THE OWNER OR REPRESENTATIVE AND TO THE FIELD INSPECTOR AT THE TIME OF FINAL INSPECTION. (5.410.4.5) ENVIRONMENTAL QUALITY NOTES 16. ARCHITECTURAL PAINTS AND COATINGS, ADHESIEVES, CAULKS AND SEALANTS SHALL COMPLY WITH THE VOLATILE ORGANIC COMPOUND (VOC) LIMITS LISTED IN TABLES 5.504.4.1-5.504.4.3 (5.504.4.1-5.504.4..3) a. THE VOC CONTENT VERIFICATION CHECK LIST, FORM GNR2, SHALL BE COMPLETED AND VERIFIED PRIOR TO FINAL INSPECTION APPROVAL. THE MANUFACTURER'S SPECIFICATIONS SHOWING VOC CONTENT FOR ALL APPLICABLE AT THE JOBSITE AND BE PROVIDED TO THE FINAL INSPECTOR FOR VERIFICATION. (5.504.4.3.2) b. ALL NEW CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENTS OF ONE OF THE FOLLOWING: i. CARPET AND RUG INSTITUTE'S GREEN LABLE PLUS PROGRAM ii. CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S SPECIFICATION 01350 iii. NSF/NASI 140 AT THE GOLD LEVEL OR HIGHER iv. SCIENTIFIC CERTIFICATIONS SYSTEMS SUSTAINABLE CHOICE v. COMPLIENT WITH THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS CALIFORNIA (CA-CHPS) CRITERIA INTERPRETATION FOR EQ 7.0 AND 7.1 AND LISTED IN THE CHPS HIGH PERFORMANCE PRODUCT DATABASE. (5.504.4.4) c. ALL NEW CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPETAND RUG INSTITUTE GREEN LABLE PROGRAM. (5.504.4.4.1) d. NEW HARDWOOD PLYWOOD, PARTICLE BOARD, AND MEDIUM DENSITY FIBERBOARD COMPOSITE WOOD PRODUCTS USED IN THE INTERIOR OR EXTERIOR OF THE BUILDING SHALL MEET THE FORMALDEHYDE LIMITS LISTED IN TABLE 5.504.4.5 (5.504.4.5) e. THE FORMALDEHYDE EMISSIONS VERIFICATION CHECKLIST, FORM GRN 3, SHALL BE COMPLETED PRIOR TO FINAL APPROVAL. THE MANUFACTURE'S SPECIFICATIONS SHOWING FORMALDEHYDE CONTENT FOR ALL APPLOCABLE WOOD PRODUCTS SHALL BE READLY AVAILABLE AT THE JOB SITE AND BE PROVIDED TO THE FIELD INSPECTOR FOR VERIFICATION (5.504.4.5) f. 80% OF THE TOTAL AREA RECEIVING RESILENT FLOORING SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING: i. CERTIFIED AS CHPS LOW-EMITTING MATERIAL IN TE CHPS HIGH PERFORMANCE PRODUCTS DATABASE ii. CERTIFIED UNDER UL GREENGUARD GOLD iii. CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM iv. MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S SPECIFICATION 01350 (5.504.4.6) g. AN AIR FILTER WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8 OR HIGHER SHALL BE INSTALLED IN THE MECHANICAL SYSTEM FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY. (5.504.5.3) h. MECHANICALLY VENTILATED BUILDINGS WITHIN 1,000 FEET OF A FREEWAY SHALL PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH A MERV 13 FILTER FOR OUTSIDE AND RETURN AIR. FILTERS SHALL BE INSTALLED PRIOR TO OCCUPANCY AND RECOMMENDATIONS FOR MAINTENANCE EITH FILTERS OF THE SAME VALUE SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. (4.504.5.3) GREEN BUILDING (CONT.) 16. HEAT ISLAND EFFECT. REDUCE NONROOF HEAT ISLANDS BY SECTION A5,106.11.1 AND ROOF HEAT ISLANDS BY SECTION A5.106.11.2 a. HARDSCAPE ALTERNATIVES. USE ONE OR A COMBINATION OF STRATEGIES 1 AND 2 OF 50 PERCENT OF SITE HARDSCAPE OR PUT 50 PERCENT OF PARKING UNDERGROUND. 1. USE LIGHT COLORED MATERIALS WITH AN INITIAL SOLAR REFLECTANCE VALUE OF AT LEAST 30 AS DETERMINED IN ACCORDANCE WITH AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) STANDARDS E1918 OR C1549. 2. USE OPEN-GRID PAVEMENT SYSTEM OR PREVIOUS OR PREMEABLE PAVEMENT SYSTEM. 17. PROVIDE A WEATHER-RESISTANT EXTERIOR WALL AND FOUNDATION ENVELOPE AS REQUIRED BY CALIFORNIA BUILDING CODE SECTION 1403.2 (WEATHER PROTECTION) AND CALIFORNIA ENERGY CODE SECTION 150, (MANDATORY FEATURES AND DEVICES), MANUFACTURER’S INSTALLATION INSTRUCTIONS OR LOCAL ORDINANCE, WHICHEVER IS MORE STRINGENT. 18. CONTRUCTION WASTE MANAGEMENT. RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2 OR 5.408.1.3; OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS MORE STRINGENT. (5.408.1) 19. TESTING AND ADJUSTING. NEW BUILDING LESS THAN 10,00 SQUARE FEET. TESTING AND ADJUSTING OF SYSTEMS SHALL BE REQUIRED FOR NEW BUILDINGS LESS THAN 10,000 SQUARE FEET OR NEW SYSTEMS TO SERVE AN ADDITION OR ALTERATION SUBJECT TO SECTION 303.1. (5.410.4) 20. (RESERVED). NOTE: FOR ENERGY-RELATED SYSTEMS UNDER THE SCOPE (SECTION 100) OF THE CALIFORNIA ENERGY CODE, INCLUDING HEATING, VENTILATION, AIR CONDITIONING (HVAC) SYSTEMS AND CONTROLS, INDOOR LIGHTING SYSTEM AND CONTROLS, AS WELL AS WATER HEATING SYSTEMS AND CONTROLS, REFER TO CALIFORNIA ENERGY CODE SECTION 120.8 FOR COMMISSIONING REQUIREMENTS AND SECTIONS 120.5, 120.6, 130.4, AND 140.9(B)3 FOR ADDITIONAL TESTING REQUIREMENTS OF SPECIFIC SYSTEMS. (5.410.4.1) 21. SYSTEMS. DEVELOP A WRITTEN PLAN OF PROCEDURES FOR TESTING AND ADJUSTING SYSTEMS. SYSTEMS TO BE INCLUDED FOR TESTING AND ADJUSTING SHALL INCLUDE, AS APPLICABLE TO THE PROJECT: 1. RENEWABLE ENERGY SYSTEMS. 2. LANDSCAPE IRRIGATION SYSTEMS. 3. WATER REUSE SYSTEMS. 22. PROCEDURES. PERFORM TESTING AND ADJUSTING PROCEDURES IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS AND APPLICABLE STANDARDS ON EACH SYSTEM. (5.410.4.3) 23. HVAC BLANCING. IN ADDITION TO TESTING AND ADJUSTING, BEFORE A NEW SPACE-CONDITIONING SYSTEM SERVING A BUILDING OR SPACE IS OPERATED FOR NORMAL USE, BALANCE THE SYSTEM IN ACCORDANCE WITH THE PROCEDURES DEFINED BY THE TESTING ADJUSTING AND BALANCING BUREAU NATIONAL STANDARDS; THE NATIONAL ENVIRONMENTAL BALANCING BUREAU PROCEDURAL STANDARDS; ASSOCIATED AIR BALANCE COUNCIL NATIONAL STANDARDS OR AS APPROVED BY THE ENFORCING AGENCY. (5.410.4.3.1) 24. REPORTING. AFTER COMPLETION OF TESTING, ADJUSTING AND BALANCING, PROVIDE A FINAL REPORT OF TESTING SIGNED BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE SERVICES. (5.410.4.4) 25. OPERATION AND MAINTENANCE (O&M) MANUAL. PROVIDE THE BUILDING OWNER OR REPRESENTATIVE WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTIES/WARRANTIES FOR EACH SYSTEM. O & M INSTRUCTIONS SHALL BE CONSISTENT WITH OSHA REQUIREMENTS IN CCR, TITLE 8, SECTION 5142, AND OTHER RELATED REGULATIONS. 26. INSPECTIONS AND REPORTS. INCLUDE A COPY OF ALL INSPECTION VERIFICATIONS AND REPORTS REQUIRED BY THE ENFORCING AGENCY. (5.410.4.5.1) 27. TESTING AND ADJUSTING. NEW BUILDING LESSTESTING AND ADJUSTING OF SYSTEMS SHALL BE REQUIRED FOR NEW BUILDINGS LESS THAN 10,000 SQUARE FEET OR NEW SYSTEMS TO SERVE AN ADDITION OR ALTERATION SUBJECT TO SECTION 303.1. 28. TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF CONSTRUCTION. (5.504.1) 29. COVERING OF DUCT OPENING AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. (5.504.3) 30. REDUCTION OF HEAT ISLAND EFFECT FOR NONROOF AREA. REDUCE NONROOF HEAT ISLANDS FOR 50 PERCENT OF SIDEWALKS, PATIOS, DRIVEWAYS OR OTHER PAVED AREAS BY USING ONE OR MORE OF THE METHODS LISTED. 1. TREES OR OTHER PLANTINGS TO PROVIDE SHADE AND THAT MATURE WITHIN 15 YEARS OF PLANTING. TREES SHOULD BE NATIVE OR ADAPTIVE TO THE REGION AND CLIMATE ZONES AND NONINVASIVE; HARDY AND RESISTANT TO DROUGHT, INSECTS AND DISEASE; EASY TO MAINTAIN (NO FREQUENT SHEDDING OF TWIGS, BRANCHES, UNWANTED FRUIT OR SEED PODS); AND SUITABLE IN MATURE SIZE AND ENVIRONMENTAL REQUIREMENTS FOR THE SITE. TREE SELECTION AND PLACEMENT SHOULD CONSIDER LOCATION AND SIZE OF AREAS TO BE SHADED, LOCATION OF UTILITIES, VIEWS FROM THE STRUCTURE, DISTANCE TO SIDEWALKS AND FOUNDATIONS, OVERHANGS ONTO ADJACENT PROPERTIES AND STREETS; OTHER INFRASTRUCTURE AND ADJACENT TO LANDSCAPING. IN ADDITION, SHADING SHALL NOT CAST A SHADOW, AS SPECIFIED, ON ANY NEIGHBORING SOLAR COLLECTORS PURSUANT TO PUBLIC RESOURCES CODE SECTION 25981, ET SEQ. (SOLAR SHADE CONTROL ACT). 2. USE HIGH ALBEDO MATERIALS WITH AN INITIAL SOLAR REFLECTANCE VALUE OF AT LEAST 0.30 AS DETERMINED IN ACCORDANCE WITH AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) STANDARDS E1918 OR C1549. 3. USE OPEN GRID PAVEMENT SYSTEM OR PERVIOUS OR PERMEABLE PAVEMENT SYSTEM. 4. LOCATE 50 PERCENT OF PARKING UNDERGROUND OR USE MULTILEVEL PARKING. 5. OTHER METHODS OF REDUCING HEAT ISLAND EFFECTS ACCEPTABLE TO THE ENFORCING AGENCY. NOTE: LOCAL AGENCIES MAY HAVE ORDINANCES REQUIRING MITIGATION OF HEAT ISLAND EFFECTS THROUGH BUILDING OR PARKING LOT SHADING, TREE PLANTINGS, LANDSCAPING, USE OF PERVIOUS PAVEMENTS AND OTHER APPROVED METHODS. (4.106.7) 31. ENHANCED DURABILITY AND REDUCED MAINTENANCE. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. (4.406.1) 32. WHERE MULTI-FAMILY DWELLINGS AND R OCCUPANCIES OTHER THAN ONE AND TWO-FAMILY DWELLINGS AND TOWNHOUSES ARECONSTRUCTED ON A BUILDING SITE, 5% OF THE TOTAL PARKING SPACES, BUT NOT LESS THAN ONE, SHALL BE ELECTRIC VEHICLECHARGING SPACES (EV SPACES) CAPABLE OF SUPPORTING FUTURE ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). CALCULATIONS FOR THE REQUIRED NUMBER OF EV SPACES SHALL BE ROUNDED UP TO THE NEAREST WHOLE NUMBER. SHOW ON PLANS THAT THE FOLLOWING ARE PROVIDED: A.WHERE ONLY ONE EV SPACE IS REQUIRED, INSTALL A MINIMUM 1-INCH (INSIDE DIAMETER) RACEWAY TO ACCOMMODATE A DEDICATED 208/240 VOLT BRANCH CIRCUIT. RACEWAY SHALL ORIGINATE AT THE MAIN SERVICE OR SUBPANEL AND TERMINATE IN CLOSE PROXIMITY TO THE EV SPACE INTO A LISTED CABINET, BOX OR ENCLOSURE. B.WHERE MULTIPLE CHARGING SPACES ARE REQUIRED, SHOW RACEWAY TERMINATION POINTS. C.THE MINIMUM LENGTH OF EACH EV SPACE SHALL BE 18 FEET. D.THE MINIMUM WIDTH OF EACH EV SPACE SHALL BE 9 FEET. E.FOR BUILDINGS WITH 17 OR MORE DWELLING UNITS, AT LEAST ONE OF THE REQUIRED EV SPACES SHALL BE LOCATED IN COMMON USE AREAS, EQUIPPED WITH AN EV CHARGING STATION AND AVAILABLE FOR USE BY ALL RESIDENTS. F.FOR BUILDINGS WITH 17 OR MORE DWELLING UNITS, ONE IN EVERY 25 EV SPACES, BUT NOT LESS THAN ONE, SHALL ALSO COMPLY WITH THE FOLLOWING: I.8 FT. WIDE AISLE NEXT TO THE 9 FT. WIDE EV SPACE OR A 5 FT. WIDE AISLE NEXT TO A 12 FT. WIDE EV SPACE. II.THE SURFACE SLOPE FOR THIS EVCS AND THE AISLE SHALL NOT EXCEED 1 UNIT VERTICAL IN 48 UNITS HORIZONTAL (2.083 PERCENT SLOPE) ON ANY DIRECTION. III.THE EV SPACE SHALL EITHER BE LOCATED ADJACENT TO AN ACCESSIBLE PARKING SPACE MEETING THE REQUIREMENTS OF LABC CHAPTER 11A TO ALLOW THE USE OF THE EV CHARGER FROM THE ACCESSIBLE PARKING SPACE, OR BE LOCATED ON AN ACCESSIBLE ROUTE TO THE BUILDING AS DEFINED IN CHAPTER 2 OF THE LABC. G."THE ELECTRICAL SYSTEM SHALL HAVE SUFFICIENT CAPACITY TO SIMULTANEOUSLY CHARGE ALL DESIGNATED EV SPACES AT THE FULL RATED AMPERAGE OF THE EVSE. PLAN DESIGN SHALL BE BASED UPON A 40-AMPERE MINIMUM BRNACH CIRCUIT. A SEPARATE ELECTRICAL PERMIT IS REQUIRED." H."THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT PROTECTIVE SPACE(S) RESERVED FOR FUTURE EV CHARGING PURPOSES AS EV CAPABLE IN ACCORDANCE WITH THE LOS ANGELES ELECTRICAL CODE. (4.106.4.2, 4.106.4.3) GREEN BUILDING (CONT.) 33. A COPY OF THE CONSTRUCTION DOCUMENTS OR A COMPARABLE DOCUMENT INDICATING THE INFORMATION FROM ENERGY CODE SECTIONS 110.10(b) THROUHG 110.10 (c) SHALL BE PROVIDED TO THE OCCUPANT. (ENERGY CODE 110.109(d)) 34. PROJECT WITH NEW LANDSCAPE AREAS OF 500 SQUARE FEET OR MORE ARE SUBJECT TO THE 2015 MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO). REFER TO THE MWELO SUPPLEMENTAL CORRECTION SHEET FOR ADDITIONAL COMMENTS. (4.304.1) 35. NONABSORBENT INTERIOR FLOOR AND WALL FINISHES SHALL BE USED WITHIN AT LEAST 2 FEET AROUND AND PERPENDICULAT TO EXTERIOR ENTRIES AND OR OPENING SUBJECT TO FOOT TRAFIC (5.407.2.2.1) SIGNS: 1.PROVIDE EXIT SIGNS AND DIRECTIONAL EXIT SIGNS WITH MINIMUM 6" HIGH BY 3/4" STROKE BLOCK LETTERS ON A CONTRASTING BACKGROUND. 2.PROVIDE FLOOR-LEVEL EXIT SIGNS IN ACCORDANCE WITH CBC 1011.6 IN ALL INTERIOR CORRIDORS SERVING GUESTROOMS AND RESIDENTIAL UNITS. 3.EVERY ASSEMBLY AREA SHALL HAVE THE OCCUPANT LOAD POSTED IN CONSPICUOUS PLACE NEAR THE MAIN EXIT OF THE ROOM. CBC 1004.3 4.PROVIDE STAIRWAY NUMBERING SYSTEM FOR BUILDING THREE OR MORE STORIES. 5.PROVIDE APPROVED BRAILLE SIGNAGE FOR ALL PERMANENTLY SIGNED ROOM/SPACES/ SIGN TO BE MOUNTED AT THE STRIKE SIDE OF DOORS AT 60" OFF. 6.PROVIDE A "NO SMOKING" SIGN. THE SIZE OF THE SIGN SHALL BE MINIMUM OF 40 SQ. IN., WITH INTERNATIONAL "NO SMOKING" SYMBOL IN RED OR 1" HIGH LETTERS SAYING "NO SMOKING". LOCATE SIGN 60" ABOVE FINISH FLOOR. 7.SUBMIT MANUFACTURER'S INSTALLATION INSTRUCTION FOR SMOKE DETECTORS TO THE BUILDING INSPECTOR. 8.PROVIDE APPROVED PATH MARKING IN ALL INTERIOR RATED CORRIDORS CONNECTING WITH THE FLOOR LEVEL EXIT SIGNS IN ACCORDANCE WITH CBC 1011.7 9.ALL WALLS REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING. SUCH IDENTIFICATION SHALL: 1. BE LOCATED IN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACES; 2. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION; AND 3. INCLUDING LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8" STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORD: "FIRE AND/OR SMOKE BARRIER-PREOTECT ALL OPENING" 10.EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED 11.EXIT SIGNS ILLUMINATED BY AN EXTERNAL SOURCE SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDELS (54 LUX). 12.INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACORDANCE EITH THE MANUFACTURE'S INSTRUCTIONS AND SECTION 27002. 13. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWERED SYSTEM THAT WILL PROVIDE AN ILLUMINATION OF NOT LESS THAN 90MIN. IN CASE OF PRIMARY POWER LOSS. (1013.5-1013.6.3) 14.EGRESS DOOR SHALL BE REASILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. (1010.1.9) 15.DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MIN. 34" AND MAX 48" ABOVE THE FINISH FLOOR. (1010.1.9.2) 16.ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH SECTION 1010.1.9 18.THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT CANDEL AT THE WALKING SURFACE. (1008.1) 19. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALY BE PROVIDED BY THE PREMISES ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS (1008.3): a. AISLES AND UNENCLOSED EGRESS STAIREAYS IN ROOMS AND SPACES THA REQUIRE TWO OR MORE MEANS OF EGRESS; b. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TO OR MORE EXISTS.; c. EXTERIOR EGRESS COMPONENTS AT OTHER THAN THEIR LEVEL OF EXIT DISCHARGE UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIREDTO HAVE TWO OR MORE EXITS. d. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITED IN SECTION 1028.1, IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. e. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1010.1.6. FOR EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. 20.THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPTMENT OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH SECTION 2702. (1008.3) 21.EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1 FOOT-CANDLE (11 LUX) AND A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE (1 LUX) MEASURED LONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALLBE PERMITED TO DECLINE TO 0.6 FOOT-CANDEL (0.6 LUX) AVERAGE AND MINIMUM AT ANY POINT OF 0.06 FOT-CANDEL (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. (1008.3) 22. THE EXIT SIGNS SHALL ALSO BE CONNECTED TO AN EMERFENCY ELECTRICAL SYSTEM PROVIDED FOM STORAGE BATTERIES UNIT EQUIPMENT OR AN ON-SITE GENERATOR SET, AND THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE ELECTRICAL CODE. FOR HIGH RISE BUILDINGS, SEE SECTION 403. SECTION 1025 LUMINOUS EGRESS PATH MARKINGS 1025.1 GENERAL. APPROVED LUMINOUS EGRESS PATH MARKINGS DELINEATING THE EXIT PATH SHALL BE PROVIDED IN HIGH-RISE BUILDINGS OF GROUP A, B, E, I, M, AND R-1 OCCUPANCIES IN ACCORDANCE WITH SECTIONS 1025.1 THROUGH 1025.5. EXCEPTION:LUMINOUS EGRESS PATH MARKINGS SHALL NOT BE REQUIRED ON THE LEVEL OF EXIT DISCHARGE IN LOBBIES THAT SERVE AS PART OF THE EXIT PATH IN ACCORDANCE WITH SECTION 1028.1, EXCEPTION 1. 1025.2 MARKINGS WITHIN EXIT COMPONENTS. EGRESS PATH MARKINGS SHALL BE PROVIDED IN INTERIOR EXIT STAIRWAYS, INTERIOR EXIT RAMPS AND EXIT PASSAGEWAYS, IN ACCORDANCE WITH SECTIONS 1025.2.1 THROUGH 1025.2.6. 1025.2.1 STEPS. A SOLID AND CONTINUOUS STRIPE SHALL BE APPLIED TO THE HORIZONTAL LEADING EDGE OF EACH STEP AND SHALL EXTEND FOR THE FULL LENGTH OF THE STEP. OUTLINING STRIPES SHALL HAVE A MINIMUM HORIZONTAL WIDTH OF 1 INCH (25 MM) AND A MAXIMUM WIDTH OF 2 INCHES (51 MM). THE LEADING EDGE OF THE STRIPE SHALL BE PLACED NOT MORE THAN 1/2 INCH (12.7 MM) FROM THE LEADING EDGE OF THE STEP AND THE STRIPE SHALL NOT OVERLAP THE LEADING EDGE OF THE STEP BY NOT MORE THAN 1/2 INCH (12.7 MM) DOWN THE VERTICAL FACE OF THE STEP. EXCEPTION:THE MINIMUM WIDTH OF 1 INCH (25 MM) SHALL NOT APPLY TO OUTLINING STRIPES LISTED IN ACCORDANCE WITH UL 1994. 1025.2.2 LANDINGS. THE LEADING EDGE OF LANDINGS SHALL BE MARKED WITH A STRIPE CONSISTENT WITH THE DIMENSIONAL REQUIREMENTS FOR STEPS. 1025.2.3 HANDRAILS. HANDRAILS AND HANDRAIL EXTENSIONS SHALL BE MARKED WITH A SOLID AND CONTINUOUS STRIPE HAVING A MINIMUM WIDTH OF 1 INCH (25 MM). THE STRIPE SHALL BE PLACED ON THE TOP SURFACE OF THE HANDRAIL FOR THE ENTIRE LENGTH OF THE HANDRAIL, INCLUDING EXTENSIONS AND NEWEL POST CAPS. WHERE HANDRAILS OR HANDRAIL EXTENSIONS BEND OR TURN CORNERS, THE STRIPE SHALL NOT HAVE A GAP OF MORE THAN 4 INCHES (102 MM). EXCEPTION:THE MINIMUM WIDTH OF 1 INCH (25 MM) SHALL NOT APPLY TO OUTLINING STRIPES LISTED IN ACCORDANCE WITH UL 1994. 1025.2.4 PERIMETER DEMARCATION LINES. STAIR LANDINGS AND OTHER FLOOR AREAS WITHIN INTERIOR EXIT STAIRWAYS, INTERIOR EXIT RAMPS AND EXIT PASSAGEWAYS, WITH THE EXCEPTION OF THE SIDES OF STEPS, SHALL BE PROVIDED WITH SOLID AND CONTINUOUS DEMARCATION LINES ON THE FLOOR OR ON THE WALLS OR A COMBINATION OF BOTH. THE STRIPES SHALL BE 1 TO 2 INCHES (25 MM TO 51 MM) WIDE WITH INTERRUPTIONS NOT EXCEEDING 4 INCHES (102 MM). EXCEPTION:THE MINIMUM WIDTH OF 1 INCH (25 MM) SHALL NOT APPLY TO OUTLINING STRIPES LISTED IN ACCORDANCE WITH UL 1994. 1025.2.4.1 FLOOR-MOUNTED DEMARCATION LINES. PERIMETER DEMARCATION LINES SHALL BE PLACED WITHIN 4 INCHES (102 MM) OF THE WALL AND SHALL EXTEND TO WITHIN 2 INCHES (51 MM) OF THE MARKINGS ON THE LEADING EDGE OF LANDINGS. THE DEMARCATION LINES SHALL CONTINUE ACROSS THE FLOOR IN FRONT OF ALL DOORS. EXCEPTION:DEMARCATION LINES SHALL NOT EXTEND IN FRONT OF EXIT DISCHARGE DOORS THAT LEAD OUT OF AN EXIT AND THROUGH WHICH OCCUPANTS MUST TRAVEL TO COMPLETE THE EXIT PATH. 1025.2.4.2 WALL-MOUNTED DEMARCATION LINES.PERIMETER DEMARCATION LINES SHALL BE PLACED ON THE WALL WITH THE BOTTOM EDGE OF THE STRIPE NOT MORE THAN 4 INCHES (102 MM) ABOVE THE FINISHED FLOOR. AT THE TOP OR BOTTOM OF THE STAIRS, DEMARCATION LINES SHALL DROP VERTICALLY TO THE FLOOR WITHIN 2 INCHES (51 MM) OF THE STEP OR LANDING EDGE. DEMARCATION LINES ON WALLS SHALL TRANSITION VERTICALLY TO THE FLOOR AND THEN EXTEND ACROSS THE FLOOR WHERE A LINE ON THE FLOOR IS THE ONLY PRACTICAL METHOD OF OUTLINING THE PATH. WHERE THE WALL LINE IS BROKEN BY A DOOR, DEMARCATION LINES ON WALLS SHALL CONTINUE ACROSS THE FACE OF THE DOOR OR TRANSITION TO THE FLOOR AND EXTEND ACROSS THE FLOOR IN FRONT OF SUCH DOOR. EXCEPTION:DEMARCATION LINES SHALL NOT EXTEND IN FRONT OF EXIT DISCHARGE DOORS THAT LEAD OUT OF AN EXIT AND THROUGH WHICH OCCUPANTS MUST TRAVEL TO COMPLETE THE EXIT PATH. 1025.2.4.3 TRANSITION. WHERE A WALL-MOUNTED DEMARCATION LINE TRANSITIONS TO A FLOOR- MOUNTED DEMARCATION LINE, OR VICE VERSA, THE WALL-MOUNTED DEMARCATION LINE SHALL DROP VERTICALLY TO THE FLOOR TO MEET A COMPLIMENTARY EXTENSION OF THE FLOOR-MOUNTED DEMARCATION LINE, THUS FORMING A CONTINUOUS MARKING. 1025.2.5 OBSTACLES. OBSTACLES AT OR BELOW 6 FEET 6 INCHES (1981 MM) IN HEIGHT AND PROJECTING MORE THAN 4 INCHES (102 MM) INTO THE EGRESS PATH SHALL BE OUTLINED WITH MARKINGS NOT LESS THAN 1 INCH (25 MM) IN WIDTH COMPRISED OF A PATTERN OF ALTERNATING EQUAL BANDS, OF LUMINOUS MATERIAL AND BLACK, WITH THE ALTERNATING BANDS NOT MORE THAN 2 INCHES (51 MM) THICK AND ANGLED AT 45 DEGREES (0.79 RAD). OBSTACLES SHALL INCLUDE, BUT ARE NOT LIMITED TO, STANDPIPES, HOSE CABINETS, WALL PROJECTIONS AND RESTRICTED HEIGHT AREAS. HOWEVER, SUCH MARKINGS SHALL NOT CONCEAL ANY REQUIRED INFORMATION OR INDICATORS INCLUDING BUT NOT LIMITED TO INSTRUCTIONS TO OCCUPANTS FOR THE USE OF STANDPIPES. 1025.2.6 DOORS WITHIN THE EXIT PATH. DOORS THROUGH WHICH OCCUPANTS MUST PASS IN ORDER TO COMPLETE THE EXIT PATH SHALL BE PROVIDED WITH MARKINGS COMPLYING WITH SECTIONS 1025.2.6.1 THROUGH 1025.2.6.3. 1025.2.6.1 EMERGENCY EXIT SYMBOL.THE DOORS SHALL BE IDENTIFIED BY A LOW-LOCATION LUMINOUS EMERGENCY EXIT SYMBOL COMPLYING WITH NFPA 170. THE EXIT SYMBOL SHALL BE NOT LESS THAN 4 INCHES (102 MM) IN HEIGHT AND SHALL BE MOUNTED ON THE DOOR, CENTERED HORIZONTALLY, WITH THE TOP OF THE SYMBOL NOT HIGHER THAN 18 INCHES (457 MM) ABOVE THE FINISHED FLOOR. 1025.2.6.2 DOOR HARDWARE MARKINGS. DOOR HARDWARE SHALL BE MARKED WITH NOT LESS THAN 16 SQUARE INCHES (406 MM2) OF LUMINOUS MATERIAL. THIS MARKING SHALL BE LOCATED BEHIND, IMMEDIATELY ADJACENT TO, OR ON THE DOOR HANDLE OR ESCUTCHEON. WHERE A PANIC BAR IS INSTALLED, SUCH MATERIAL SHALL NOT BE LESS THAN 1 INCH (25 MM) WIDE FOR THE ENTIRE LENGTH OF THE ACTUATING BAR OR TOUCH-PAD. 1025.2.6.3 DOOR FRAME MARKINGS. THE TOP AND SIDES OF THE DOOR FRAME SHALL BE MARKED WITH A SOLID AND CONTINUOUS 1-INCH-TO 2-INCH-WIDE (25 MM TO 51 MM) STRIPE. WHERE THE DOOR MOLDING DOES NOT PROVIDE SUFFICIENT FLAT SURFACE ON WHICH TO LOCATE THE STRIPE, THE STRIPE SHALL BE PERMITTED TO BE LOCATED ON THE WALL SURROUNDING THE FRAME. 1025.3 UNIFORMITY. PLACEMENT AND DIMENSIONS OF MARKINGS SHALL BE CONSISTENT AND UNIFORM THROUGHOUT THE SAME ENCLOSURE. 1025.4 SELF-LUMINOUS AND PHOTOLUMINESCENT. LUMINOUS EGRESS PATH MARKINGS SHALL BE PERMITTED TO BE MADE OF ANY MATERIAL, INCLUDING PAINT, PROVIDED THAT AN ELECTRICAL CHARGE IS NOT REQUIRED TO MAINTAIN THE REQUIRED LUMINANCE. SUCH MATERIALS SHALL INCLUDE, BUT NOT BE LIMITED TO, SELF- LUMINOUS MATERIALS AND PHOTOLUMINESCENT MATERIALS. MATERIALS SHALL COMPLY WITH EITHER OF THE FOLLOWING STANDARDS: 1. UL 1994. 2. ASTM E2072, EXCEPT THAT THE CHARGING SOURCE SHALL BE 1 FOOTCANDLE (11 LUX) OF FLUORESCENT ILLUMINATION FOR 60 MINUTES, AND THE MINIMUM LUMINANCE SHALL BE 30 MILICANDELAS PER SQUARE METER AT 10 MINUTES AND 5 MILICANDELAS PER SQUARE METER AFTER 90 MINUTES. 1025.5 ILLUMINATION. WHERE PHOTOLUMINESCENT EXIT PATH MARKINGS ARE INSTALLED, THEY SHALL BE PROVIDED WITH NOT LESS THAN 1 FOOTCANDLE (11 LUX) OF ILLUMINATION FOR NOT LESS THAN 60 MINUTES PRIOR TO PERIODS WHEN THE BUILDING IS OCCUPIED AND CONTINUOUSLY DURING OCCUPANCY. SECTION 11B-806.3 GUEST ROOMS WITH COMMUNICATION FEATURES GUEST ROOMS REQUIRED TO PROVIDE COMMUNICATION FEATURES SHALL COMPLY WITH SECTION 11B-806.3. 11B-806.3.1 ALARMS WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, FIRE ALARMS SHALL COMPLY WITH SECTION 11B-702 AND CARBON MONOXIDE ALARMS SHALL COMPLY WITH CHAPTER 9, SECTION 915. 11B-806.3.2 NOTIFICATION DEVICES VISIBLE NOTIFICATION DEVICES SHALL BE PROVIDED TO ALERT ROOM OCCUPANTS OF INCOMING TELEPHONE CALLS AND A DOOR KNOCK OR BELL. NOTIFICATION DEVICES SHALL NOT BE CONNECTED TO VISIBLE ALARM SIGNAL APPLIANCES. TELEPHONES SHALL HAVE VOLUME CONTROLS COMPATIBLE WITH THE TELEPHONE SYSTEM AND SHALL COMPLY WITH SECTION 11B-704.3. TELEPHONES SHALL BE SERVED BY AN ELECTRICAL OUTLET COMPLYING WITH SECTION 11B-309 LOCATED WITHIN 48 INCHES (1219 MM) OF THE TELEPHONE TO FACILITATE THE USE OF A TTY. NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 48 " M A X . 34 " M A X . >10"- 24" MAX. 34 " M A X . 46 " M A X . 48 " M A X . 10" MAX. (B) 11B-308.3.2(A) - OBSTRUCTED HIGH SIDE REACH ≤ 10" MAX. 10" MAX. (C) 11B-308.3.2(B) -OBSTRUCTED HIGH SIDE REACH > 10" TO 24" MAX. MAX. 10" MAX. 24" (A) 11B-308.3.1 - UNOBSTRUCTION SIDE REACH MI N . 15 " 44 " M A X . 48 " M A X . 20" MAX. 48 " M A X . (A) 11B-308.2.1 UNOBSTRUCTED FORWARD REACH MI N . 15 " (B) 11B-308.2.2 FORWARD REACH OVER OBSTRUCTION ≤ 20" MAX. REACH DEPTH (C) 11B-308.2.2 FORWARD REACH OVER OBSTRUCTION > 20" TO 25" MAX. REACH DEPTH >20"-25" MAX. 30 " M I N . 17" - 25" 30 " M I N . 25" MAX. MI N . 9" 11B-306.2 TOE CLEARANCE - GENERAL REQUIREMENT 11B-306.3 KNEE CLEARANCE - GENERAL REQUIREMENT ELEVATION PLAN ELEVATION PLAN MI N . 9" MIN. 11" MAX. 6" 27 " M I N . 8" MIN. ELEVATION @ LAVATORY MI N . 9" MIN. 11" 8" MIN. 27 " M I N . 29 " M I N . CANE DETECTION BARRIER PROTECT THIS AREA FROM CROSS TRAFFIC X < 8 0 " 27 " M A X . 11B-307.4 11B-307 PROTECTION AROUND WALL-MOUNTED OBJECTS ADDITIONAL PROTECTION NOT REQUIRED BETWEEN WING WALLS PROTRUDING OBJECTS HANGING ON WALL WITH LEADING EDGES ABOVE 27" MAX. 24" DIMENSION ANY CL R . W I D T H 36 " M I N . PA S S A G E 32 " M I N . CL R . W I D T H 4" M A X . 11B-307.4 X > 2 7 " 4" MAX X ≥ 8 0 " 11B-307.2 11B-304.3.1 CIRCULAR SPACE 60" MIN. 60 " M I N . MI N . 60 " MIN. 36"MIN. 12" MIN. 12" MI N . 24 " MI N . 36 " MIN. 60" 11B-304.3.2 'T'-SHAPED TURNING SPACE WHEELCHAIR TURNING SPACE MA X . 24 " X> 2 4 " 30" MIN. 36" MIN. IF X > 24", ADDITIONAL MANEUVERING CLEARANCE OF 6" SHALL BE PROVIDED MA X . 15 " MIN. 48" MI N . 30 " X> 1 5 " 60" MIN. MI N . 30 " 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH IF X > 15", ADDITIONAL MANEUVERING CLEARANCE OF 12" SHALL BE PROVIDED WHEELCHAIR MANEUVERING SPACE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH 11B-403.5 - CLEAR WIDTH OF AN ACCESSIBLE ROUTE MI N . 36 " MI N . 32 " 48" MIN.MAX. 24" MAX. 24" 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS 12" MAX.12" MAX. 27 " - 8 0 " X > 12" 27 " M A X . X > 12" 80 " M I N . FINISH FLOOR MAXIMUM SLOPE 11B-303.3 BEVELED CHANGE IN LEVEL 11B-303.2 CARPET PILE HEIGHT 11B-303.2 VERTICAL CHANGE IN LEVEL 1 2 1/ 4 1/ 4 " " 1/ 2 " M A X . 1/ 4 " M A X . FINISH FLOOR CARPET FINISH FLOOR PI L E 1/ 2 " M A X . DOMINANT DIRECTION OF TRAVEL OP E N MAX. 1/2" LONG DIMENSION PERPENDICULAR TO DOMINANT DIRECTION OF TRAVEL 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GUARD SURFACES FRONT APPROACH SWINGING DOOR PULL SIDE X = 18" MIN Y = 24" MIN @ EXTERIOR SIDE OF EXTERIOR DOOR 60 " M I N . FRONT APPROACH (B) SLIDING DOOR (C) FOLDING DOOR 48 " M I N . (A) HINGED DOOR 48 " M I N . 42 " M I N . SIDE APPROACH 32" MIN. 22" MIN. 42 " M I N . POCKET OR HINGE APPROACH 42 " M I N . 24" MIN. STOP OR LATCH APPROACH90°32" MIN.32" MIN. 11B-404.2.3 CLEAR WIDTH OF DOORWAYS X 48 " M I N . FRONT APPROACH SWINGING DOOR PUSH SIDE X=12" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER. MIN. 24" LATCH SIDE APPROACH SWINGING DOOR PULL SIDE LATCH SIDE APPROACH SWINGING DOOR PUSH SIDE Y=48" MIN. IF DOOR HAS A CLOSER. Y = 4 4 " M I N . Y X MIN. 36" 60 " M I N . HINGE SIDE APPROACH SWINGING DOOR PULL SIDE HINGE SIDE APPROACH SWINGING DOOR PUSH SIDE Y=48" MIN. IF DOOR HAS BOTH A LATCH AND A CLOSER. MIN. 22" Y = 4 4 " M I N . 54" MIN. MIN. 24" 11B-404.2.4.1 MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATES 11B-404.2.4.2 MANEUVERING CLEARANCE AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS 48 " M I N . 11B-404.2.6 DOORS AND GATES IN SERIES 48 " M I N . 60 " M I N . X > 8 " Y X PULL SIDE APPROACH X = 18" MIN Y = 24" MIN @ EXTERIOR SIDE OF EXTERIOR DOOR 48 " M I N . X > 8 " PUSH SIDE APPROACH 48 " M I N . PUSH SIDE APPROACH DOOR WITH BOTH CLOSER AND LATCH 12" MIN. 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES X > 8 " 60 " M I N . 60 " M I N . 44 " M I N . CO R R I D O R OC C . L O A D ≥ 1 0 CO R R I D O R OV E R 2 0 0 F E E T 33" MIN.33" MIN. 60 " M I N . SINGLE SPACE WHEELCHAIR SPACES MI N . 48 " 60 " M I N . 60" MIN. MI N . 16 " MI N . 44 " 44 " M I N . 44" MIN. 44 " M I N . 11B-403.5.1 EXCEPT AS PROVIDED IN SECTIONS 11B-403.5.2 AND 11B-403.5.3. THE CLEAR WIDTH OF WALKING SURFACES SHALL BE 36" MINIMUM. EXCEPTION 2. THE CLEAR WIDTH FOR WALKING SURFACES IN CORRIDORS SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE 44" MINIMUM. WHEELCHAIR PASSAGE WIDTH 11B-403.5.3 AN ACCSSIBLE ROUTE WITH A CLEAR WIDTH LESS THAN 60" SHALL PROVIDE PASSING SPACES AT INTERVALS OF 200' MAXIMUM. 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES 36" MIN. 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES TWO SPACES FRONT OR REAR ENTRY SIDE ENTRY 90° TURN AROUND ELEMENT > 48" WIDE MIN. 36"X > 48" MIN. 36" MI N . 36 " MIN. 36" X < 48" MIN. 36" MI N . 60 " MIN. 42" X < 48" MIN. 42" MI N . 48 " 11B-403.5.2 180° TURN 11B-403.5.2 180° TURN (EXCEPTION) 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 1 3 A M G4.a BARRIER FREE REQUIREMENTS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SCALE:NTS G4 . a1SIDE REACH SCALE: NTS G4 . a2FORWARD REACH SCALE: NTS G4 . a4KNEE AND TOE CLEARANCES SCALE: NTS G4 . a5VERTICAL CLEARANCE SCALE: NTS G4 . a6PROTRUDING OBJECTS SCALE: NTS G4 . a7PROTRUDING LIMITS SCALE: NTS G4 . a8WHEELCHAIR CLEAR SPACE SCALE: NTS G4 . a9POST-MOUNTED OBJECTS SCALE: NTS G4 . a10ACC. CHANGE IN LEVEL SCALE: NTS G4 . a11OPENINGS SCALE: NTS G4 . a13ACCESSIBLE ROUTE CLEAR WIDTH SCALE: NTS G4 . a12DOORS, DOORWAYS AND GATES MANEUVERING CLEARANCES SCALE: NTS G4 . a16CLEAR WIDTH AT TURN NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 WALL EDGED RAMP CURB EDGED RAMP NOTE: PER 11B-405.8 IF A RAMP HAS A RISE > 6" OR A HORIZONTAL PROJECTION > 72" THEN IT SHALL HAVE HANDRAILS ON BOTH SIDES COMPLYING WITH SECT. 11B-505. HANDRAIL CURB 4" M I N . C O N T . MIN. 48" 38 " M A X . 34 " M I N . GU I D E C U R B HANDRAIL EXTENSION SEE 2/G0.33 HANDRAIL SEE 4/G0.33 11B-405.9 - EDGE PROTECTION 38 " M A X . 34 " M I N < 4 " 27 " M A X . 27 " M A X . 12" MIN.12" MIN. BEYOND BOTTOM OF RAMP RUN BEYOND TOP OF RAMP RUN 11B-505.10.1 -TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS. MA X . 2 1/4" MAX. MAX. 2 1/4" 4" -6 1/4" PERIMETER 11B-505.7.2 HANDRAIL WITH NON-CIRCULAR CROSS SECTION (a)(b) NOTE: 1. REFER TO 11B-505.5 AND 11B-505.6. 2. PROVIDE CONCEALED SOLID BLOCKING / BACKING IN WALL FOR MOUNTING ATTACHMENTS. FINISH F.O. WALL MIN. 1 1/2" 2" MAX 1 1/4" MIN. MIN . C L R . 1 1 / 2 " MIN. 1 1/2" 2" MAX 1 1/4" MIN. CL R . 1 1 / 2 " M I N . T.O. HANDRAIL 34" MIN - 38" MAX 18 " M I N . A. HANDRAIL CLEARANCES B. HANDRAIL IN RECESS 3" MAX. BOTTOM LANDING LANDING LANDING TOP LANDING RAMP RUN RAMP RUN RAMP RUN 72" MIN. AS R A M P R U N AT L E A S T A S W I D E 60" MIN.60" MIN. 72 " M I N . 60 " M I N . 60" MIN. LEVEL LANDING 1:12 MAX. LEVEL LANDING HORIZONTAL PROJECTION OR RUN RI S E 11B-405.7 - RAMP LANDINGS 11B-405 - RAMPS DOORWAYS AT BOTTOM LANDING SPACE OF RAMP RA M P U P DOORWAYS AT TOP LANDING SPACE OF RAMP 60" MIN. 48" MIN.60 " M I N . 60" MIN. CLR 12" MIN72 " M I N . RA M P D O W N RA M P U P 60" MIN. 24" MIN @ EXT. DOORS 18" MIN @ INT. DOORSMAX 3" 48" MIN. DO O R W I D T H PL U S 4 2 " CLR 12" MIN 42 " M I N 60" MIN. 24" MIN @ EXT. DOORS 18" MIN @ INT. DOORS MAX 3" DO O R W I D T H PL U S 4 2 " RA M P D O W N 42 " M I N 48" MIN.48" MIN. RAMP UP MA X 3" 42" MIN. 42 " M I N 48 " M I N 36" MIN DO O R W I D T H PL U S 4 2 " RAMP UP 60" MIN. 48 " M I N 36" MIN 60 " M I N . RAMP DOWN MA X 3" 42" MIN. 42 " M I N 48 " M I N 36" MIN DO O R W I D T H PL U S 4 2 " 72" MIN. 48 " M I N 36" MIN 60 " M I N . RAMP DOWN RAMP UP 60" MIN. 42 " M I N . DO O R W I D T H PL U S 4 2 " 48 " M I N . 24" MIN MA X 3" RAMP DOWN 72" MIN. 42 " M I N . DO O R W I D T H PL U S 4 2 " 48 " M I N . MA X 3"24" MIN 11B-405.7.5 DOORWAYS. WHERE DOORWAYS ARE LOCATED ADJACENT TO A RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY SECTION 11B-404.2.4 AND 11B-404.3.2 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING AREA. DOORS, WHEN FULLY OPEN, SHALL NOT REDUCE THE REQUIRED RAMP LANDING WIDTH BY MORE THAN 3." DOORS, IN ANY POSITION, SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP LANDING TO LESS THAN 42." ELEVATION OF CENTER HANDRAIL 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS STAIR PLAN X = 12" MIN. HANDRAIL EXTENSION Y = 12" PLUS TREAD WIDTH MIN. HANDRAIL EXTENSION 44 " M I N . YX Y X Y = (12" + X) MIN. 12" MIN. LA N D I N G LA N D I N G 11B-504.5 STAIR NOSINGS ANGLED RISER CURVED NOSING BEVELED NOSING 1-1/4" MAX. 1-1/4" MAX. 30° MAX. 1/2" RADIUS MAX. NOSING 11" MIN. 7" M A X . 4" M I N . 1/2" RADIUS MAX. NOSING 11" MIN. 7" M A X . 4" M I N . 1/2" RADIUS MAX. NOSING 11" MIN. 7" M A X . 4" M I N . HA N D R A I L H E I G H T 34 " M I N . - 3 8 " M A X . DOWN UP CONTRASTING STRIPING ≥ WIDTH OF STAIR CONTINUOUS HANDRAIL 34 " M I N . - 3 8 " M A X . 27 " M A X . 34 " M I N . - 3 8 " M A X . 12" MIN. 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS X NOTES: 1. STAIRS SHALL COMPLY WITH SECT. 11B-504. 2. 504.2,ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE UNIFORM RISER HEIGHT AND UNIFORM TREAD DEPTH. RISERS SHALL BE 4” MIN. AND 7” MAX. IN HEIGHT. TREADS SHALL BE 11” MIN. IN DEPTH. 3. 11B-504.3,OPEN RISERS SHALL NOT BE PERMITTED. 4. 11B-504.4, STAIR TREADS SHALL COMPLY WITH SECT. 11B-302. CHANGES IN LEVEL, SLOPES EXCEEDING 1:48, AND DETECTABLE WARNINGS SHALL NOT BE PERMITTED. 5. 11B-504.4.1 CONTRASTING STIPE. INTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND LOWER TREAD MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. EXTERIOR STAIRS SHALL HAVE THE UPPER APPROACH AND ALL TREADS MARKED BY A STRIPE PROVIDING CLEAR VISUAL CONTRAST. 6. 11B-504.5, NOSINGS SHALL COMPLY WITH SECT. 11B-504.5. STAIR NAME / NUMBER STAIR UPPER TERMINUS INDICATE W/ "ROOF ACCESS" OR "NO ROOF ACCESS" STAR SYMBOL AT EXIT DISCHARGE LEVEL ONLY INDICATES FLOOR NUMBER INDICATES FLOORS SERVED (LOWER & UPPER TERMINUS) ALL CHARACTERS TO BE RAISED MIN 1/32" FROM ABOVE THE BACKGROUND BRAILLE SHALL BE PLACED 3/8" MIN. & 1/2" MAX. DIRECTLY BELOW TACTILE CHARACTERS NOTE: REFER TO CBC 1023.9 FOR STAIR IDENTIFICATION SIGN REQUIREMENTS 12" MIN. 3/ 8 " - 1 / 2 " 18 " M I N . 1" M I N . 5" M I N . 1- 1 / 2 " M I N . 1" M I N . 48" MIN - 60" MAX. A.F.F. BASELINE OF BRAILLE CELLS 60" BOTTOM OF SIGN A.F.F. 60" MAX. ABOVE FLOOR BASELINE OF HIGHEST CHARACTER RAISED CHARACTERS ARE 5/8" MIN. & 2" MAX. BRAILLE SHALL BE PLACED 3/8" MIN. & 1/2" MAX.DIRECTLY BELOW TACTILE CHARACTERS ROOM NAME OR NUMBER 48" MIN. ABOVE FLOOR BASELINE OF LOWEST BRAILLE 404 & 2 " M A X . 5/ 8 " M I N . & 1 / 2 " M A X . 3/ 8 " M I N 3/ 8 " M I N . NOTE: REFER TO 11B-703 FOR SIGN INFORMATION. EXIT STAIR DOWN C. B. EXIT ROUTE A. EXIT RAISED CHARACTERS ARE A MIN. OF 5/8" & MAX. OF 2" BRAILLE SHALL BE PLACED A MIN. OF 3/8" & MAX. OF 1/2" DIRECTLY BELOW TACTILE CHARACTERS 60" MAX. ABOVE FLOOR BASELINE OF HIGHEST CHARACTER 48" MIN. ABOVE FLOOR BASELINE OF LOWEST BRAILLE 3/ 8 " M I N . NOTE: SIGNS REQUIRED BY CBC CHAPTER 10, SECT. 1013.4 AT DOORS TO EXIT PASSEGEWAYS, EXIT DISCHARGE AND EXIT STAIRWAYS SHALL COMPLY WITH SECTIONS 11B-703.1, 11B-703.2. 11B703.3 AND 11B-703.5. CHARACTERS SHALL BE SANS SERIF UPPERCASE ACCOMPANIED BY GRADE 2 BRAILLE. HELP PHONE "SOLID LIGHT: CALLING BLINKING LIGHT: RECEIVED" PUSH FOR HELP LOCATION FLOOR _________ ________ PERSONS ABLE TO USE THE EXIT STAIRWAY DO SO AS SOON AS POSSIBLE, UNLESS THEY ARE ASSISTING OTHERS AFTER ACTIVATING THE TWO- WAY EMERGENCY COMMUNICATION SYSTEM, WAIT HERE FOR ASSISTANCE RECESSED CALL BOX CALL BUTTON SPEAKER CALLING / RECEIVED INDICATOR LIGHT MICROPHONE INSTRUCTIONAL SIGNAGE NOTE: TWO-WAY COMMUNICATION SYSTEMS SHALL COMPLY WITH 11B-230 CENTERED ON TACTILE CHARACTERS18" MIN. CL 18 " M I N . 45° NOTE: 1. TACTILE SIGN SHALL BE LOCATED ON THE LATCH SIDE OF THE DOOR 2. TACTILE CHARACTERS ARE BOTH BRAILLE AND RAISED CHARACTERS CLEAR SPACE IN FRONT OF SIGN NOTE: REFER TO 11B-703.4.2 FOR LOCATION OF TACTILE SIGNS AT DOORS. DINING OR WORK SURFACE 30" MIN. 48 " M I N . 19 " M A X . 27 " M I N . 28 " - 3 4 " NOTE: REFER TO 11B-305 FOR CLEAR FLOOR OR GROUND SPACE AND TO 11B-306.2.3 EXCEPTION 2 FOR MIN. DEPTH REQUIREMENTS. REFER TO 11B-902.3 FOR DINING AND WORK SURFACES HEIGHT REQUIREMENTS. WATER POOL DECK16 " M I N . MIN. 12" CL E A R 36 " M I N . CLEAR 48" MIN. NOTE: REFER TO 11B-1009.2 FOR POOL LIFT REQUIREMENTS. 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 1 6 A M G4.b BARRIER FREE REQUIREMENTS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SCALE: NTS G4 . b1RAMPS SCALE: NTS G4 . b2HANDRAIL EXTENSION AT RAMPS SCALE: NTS G4 . b3HANDRAIL NON-CIRCULAR SCALE: NTS G4 . b4HANDRAIL SCALE: NTS G4 . b5RAMP COMPONENTS SCALE: NTS G4 . b6DOORWAYS AT RAMP LANDINGS SCALE: NTS G4 . b7STAIRS SCALE: NTS G4 . b8STAIR IDENTIFICATION SIGNAGE SCALE: NTS G4 . b9TYP. SIGNAGE MOUNTING HEIGHT SCALE: NTS G4 . b10EXIT SIGNAGE SCALE: NTS G4 . b11TWO-WAY COMMUNICATION SYSTEMS SCALE: NTS G4 . b12INT'L SYMBOLS OF ACCESSIBILITY SCALE: NTS G4 . b13TACTILE SIGN AT DOORS SCALE: NTS G4 . b14DINING AND WORK SURFACES SCALE: NTS G4 . b15POOL LIFT SEAT LOCATION NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 1/2" RADIUS BLUE WHITE REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL WITH BEADED TEXT OR EQUAL CI R C U L A T I O N P A T H 80 " M I N . A . F . G . W / 60 " M I N . A . F . G . A T WA L L O R L A N D S C A P E NOTE: 1. PROVIDE PASSENGER LOADING ZONE WHERE IT IS REQUIRED. 2. SIGN SHALL BE PLACED IN FRONT OF EACH ACCESSIBLE PASSENGER LOADING ZONE, WITHIN CLEAR VIEW, BUT NOT PLACED SO AS TO OBSTRUCT PASSAGE FROM ANY PARKING STALL OR WALKWAY. VEHICLE PULL-UP SPACE FULL LENGTH OFMAX. O.C.36"NOTE: 11B-503.1 ACCESS AISLES SERVING VEHICLE PULL-UP SPACES SHALL BE 60" WIDE MIN. 11B-503.2 ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE VEHICLE PULL-UP SPACES THEY SERVE. 11B-503.3.3 ACCESS AISLES SHALL BE MARKED WITH A PAINTED BORDERLINE AROUND THEIR PERIMETER. THE AREA WITHIN THE BORDERLINES SHALL BE MARKED WITH HATCHED LINES A MAXIMUM OF 36" ON CENTER IN A COLOR CONTRASTING WITH THAT OF THE AISLE SURFACE. 11B-503.4 VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM SHALL COMPLY WITH SECT. 11B-302 AND SHALL HAVE SLOPES NOT STEEPER THAN 1:48. ACCESS AISLES SHALL BE AT THE SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE; DETECTABL WARNINGS ARE NOT PERMITTED. 11B-503.5 VEHICLE PULL-UP SPACES, ACCESS AISLES SERVING THEM AND A VEHICULAR ROUTE FROM AN ENTRANCE TO THE PASSENGER DROP-OFF AND LOADING ZONE AND FROM THE PASSENGER DROP-OFF AND LOADING ZONE TO A VEHICULAR EXIT SHALL PROVIDE A VERTICAL CLEARANCE OF 114”MIN. AC C E S S A I S L E 60 " M I N . AREA TO BE MARKED CURB LINE 96 " M I N . 240" MIN. NO PARKINGEV CHARGING ONLY EV CHARGING ONLY 120" MIN @ AMBULATORY ACC. EVCS EV CHARGER WHEELSTOP 30"x48" CLEARFLOOR SPACE ACCESSIBLE ROUTE PAINT ACCESS AISLES BORDERLINE AND HATCH LINE IN A COLOR CONTRASTING W/ ADJACENT SURFACE 11B-812 - ELECTRIC VEHICLE CHARGING STATIONS 144" MIN @ VAN ACC. EVCS 60" MIN. 108" MIN. @ STDMAX.36"21 6 " M I N . 2% MAX SLOPE IN ALL DIRECTIONS DETECTABLE WARNING PARKING SPACE IDENTIFICATION PER 11B-502.6 LETTERS 12" HIGH MIN. CENTERLINE OF TEXT SHALL BE A MAX. OF 6" FROM THE CENTERLINE OF THE VEHICLE SPACE AND ITS LOWER CORNER AT, OR LOWER SIDE ALIGNED WITH, THE END OF THE VEHICLE SPACE LENGTH. 11B-502.6 -INDENTIFICATION SIGNS $250 MINIMUM FINE VAN ACCESSIBLE 1/2" RADIUS, TYP. BLUE REFLECTED SIGN CONSTRUCTED OF PORCELAIN STEEL WITH BEADED TEXT OR EQUAL DESIGNATE FOR "VAN ACCESSIBLE" AT VAN ACCESSIBLE SPACES. WHITE BLUE OR WHITE 60 " M I N . A T 80 " M I N . W / I N CI R C . P A T H FINISH GROUND SURFACE WA L L O R LA N D S C A P E 70 SQ. IN. MIN. FOR PARKING SPACE IDENTIFICATION VAN ACCESSIBLE BACKGROUND: BLUE, COLOR NO. 15090, FED. STANDARD 595C WHITE SYMBOL PROVIDE "VAN ACCESSIBLE" LETTERS WHERE APPLIES 36" SQAURE 11B-703.7.2.1 -INTERNATIONAL SYMBOL OF ACCESSIBILITY NO PARKING THE WORDS "NO PARKING" SHALL BE PAINTED ON THE SURFACE WITHIN EACH ACCESS AISLE IN WHITE 12" MIN. HIGH LETTERS OR 108" @ STD. ACC. 144" @ VAN ACC. ACCESS AISLE 60" MIN. TYP. 108" @ STANDARD ACC. 36" SQ. INTERNATIONAL SYMBOL OF ACCESSIBILITYMAX. O.C.36"90°IDENTIFICATION SIGN PER 11B-502.6 BLUE BORDER PEDESTRIAN ROUTE 21 6 " M I N . 11B-502 - PARKING SPACES 2% MAX SLOPE IN ALL DIRECTIONS ALIGN 11B-502.7.2 WHEEL STOPS. A CURB OR WHEEL STOP SHALL BE PROVIDED IF REQUIRED TO PREVENT ENCROACHMENT OF VEHICLES OVER THE REQUIRED CLEAR WIDTH OF ADJACENT ACCESSIBLE ROUTES. COLOR CONTRASTING WITH AISLE SURFACE, PREFERABLY BLUE OR WHITE DETECTABLE WARNING REDUCER DETAIL RAMP FINISH TRANSITIONS OVER 1/4" CHANGE IN LEVEL EXT. FLOOR FIN. SLAB (N) GROUT (N) CEMENTITIOUS DETECTABLE WARNING OVER LATEX THIN SET. A. ELEVATION (ENLARGED) 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES 11B-705.1.2.2.1 PERPENDICULAR CURB RAMP PER 11B-705.1.1.3 COLOR AND CONTRAST OF DETECTABLE WARNING SURFACE SHALL: 1. BE YELLOW AND APPROXIMATE 33538 OF SAE AMSSTD-59AA. 2. PROVIDE 70% MIN. VISUAL CONTRAST WITH ADJACENT WALKING SURFACES. 3. DIFFER FROM ADJOINING SURFACES IN RESILIENCY OR SOUND-ON-CANE CONTACT. WIDTH OF PATH 36 " - TOP DIAMETER OF 0.45" - 0.47" BASE DIAMETER OF 0.9" - 0.92" CL CL CLCL 2. 3 " - 2 . 4 " 2.3" - 2.4" 0. 6 5 " M I N . 0. 2 0 " B. PLAN 60" MIN. RA M P L A N D I N G 48 " M I N . DETECTABLE WARNINGS 1: 1 2 M A X . 1: 1 2 M A X . 1:10 MAX. 1:10 MAX. 1:10 MAX. 1:10 MAX. 36 " M I N . 36 " M I N . A. CUT THROUGH AT ISLAND B. CURB RAMP AT ISLAND 36 " M I N . 36 " M I N . 60" MIN. 11B-406.6 ISLANDS IN CROSSINGS A C 1:12 MAX. PARALLEL CURB RAMP 11B-406.3 11B-705.1.2.2.2 RUNNING SLOPE IN LINE WITH THE DIRECTION OF SIDEWALK TRAVEL. 1:48 MAX. CROSS SLOPE 1:12 MAX. 1: 4 8 M A X . GRADE BREAK DETECTABLE WARNINGS DIAGONAL CURB RAMP 11B-406.5.10 1:10 MAX.1:10 MAX. 1: 1 2 M A X . FLARE SIDES OF RAMP, WHERE OCCURS DETECTABLE WARNINGS 48 " M I N . 48" MIN. RA M P L A N D I N G 48 " M I N . 48" MIN. 36 " M I N .CLR.48" MIN.M I N . 2 4 " MARKED CROSSING DETECTABLE WARNINGS1:10 MAX.1:10 MAX.1:12 MAX.B PERPENDICULAR CURB RAMP 11B-406.2 11B-705.1.2.2.1 36 " M I N . 36 " M I N . 6" - 8 " 6" - 8 " 11B-705.1.2.2 CURB RAMPS6"- 8"UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT * * OR BY TELEPHONING * * 17" MIN. 22 " M I N . 60 " M I N . A . F . G . A T 80 " M I N . A . F . G . W/ I N C I R C U L A T I O N P A T H POLE WHERE APPLICABLE NOTES: REFER TO 11B-502.8 WA L L O R L A N D S C A P E 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 1 9 A M G4.c BARRIER FREE REQUIREMENTS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SCALE: NTS G4 . c1ACC. PASSENGER LOADING SIGN SCALE: NTS G4 . c2PASSENGER DROP-OFF & LOADING SCALE: NTS G4 . c3ACCESSIBLE EV CHARGING STALL SCALE: NTS G4 . c5ACC. PARKING SIGNAGE SCALE: NTS G4 . c6INT'L SYMBOL OF ACCESSIBILITY SCALE: NTS G4 . c7ACCESSIBLE PARKING STALL SCALE: NTS G4 . c4DETECTABLE WARNING SCALE: NTS G4 . c8ISLANDS IN CROSSINGS SCALE: NTS G4 . c9CURB RAMP SCALE: NTS G4 . c10TOW-AWAY SIGN NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 URINAL - PLANI 30" MIN. WHEN PARTITION ≤ 24" WIDE 36" MIN. WHEN PARTITION > 24" WIDE CLEAR SPACE LAVATORY - PLANG . MIN. 8" 25" MAX. 17" MIN. 6" MAX. 27 " M I N . 29 " M I N . 34 " M A X . FLOOR-MOUNTED TOILET - FRONT VIEWK FIN. FACE OF WALL CLEAR FLOOR SPACE 48" MIN. 30 " M I N . TO 18 " M I N . ℄ INSULATED PIPE PROTECTION 25" MAX. 17" MIN. 19" MAX. FLUSH CONTROL FIN. FACE OF WALLPARTITION 13-1/2" MIN. 17 " M A X . 44 " M A X . 18" MIN. 48" MIN. 36 " W H E N X > 2 4 " 30 " W H E N X ≤ 2 4 " EQ . E Q . MIN. 13 1/2" T. O . G R A B B A R 33 " - 3 6 " A . F . F . 6" MAX. MIN. 12"24" MIN. 36" MIN. ℄FIN. FACE OF WALL 17" - 18" FLUSH CONTROL TO BE LOCATED ON TRANSFER SIDE 24" MIN. 42" MIN. MAX. 12" 54" MIN. T. O . S E A T 17 " - 1 9 " T. O . G R A B B A R 33 " - 3 6 " A . F . F . FIN. FACE OF WALL T. O . S E A T 17 " - 1 9 " LAVATORY - SECTIONF URINAL - ELEVATIONSH WALL-HUNG TOILET - SIDE VIEWJ MIRROR TO R E F L E C T I V E 40 " M A X . TO P O F H O O K 48 " M A X . PAPER TOWEL DISPENSER W/ WASTE RECEPTACLE SANITARY NAPKIN VENDOR 40 " M A X . SU R F A C E D ECOAT HOOKCMIRRORA 40 " M A X . 34 " M A X 48 " M A X . 27 " M I N . 20" MAX. BABY CHANGING STATIONB NOTE: BABY CHANGING TABLES SHALL NOT BE LOCATED IN TOILET COMPARTMENT WITHIN A MULTIPLE ACCOMMODATION TOILET FACILITY. 7"-9" TO O P N G 19 " M I N . TOILET PAPER DISPENSER NAPKIN DISPOSAL UNIT SEAT \COVER DISPENSER TO D I S P E N S E R 40 " M A X . 12 " 1 1 / 2 " MI N . CL R . MI N . CL R . ABOVE LAVATORIES AND COUNTERS. 35" MAX. AFF. TO REFLECTIVE SURFACE WHERE NOT LOCATED ABOVE COUNTER OR LAVATORY 19" MIN. KNEE & TOE CLEARANCE BETWEEN 9" AND 27" A.F.F., THE KNEE CLEARANCE SHALL BE PERMITTED TO REDUCE AT A RATE OF 1" IN DEPTH FOR EACH 6" IN HEIGHT.11" MIN. MA X . 12 " URINAL DEPTH 6" MIN. (WHICHEVER IS GREATER) 18" MIN. NOTE: REFER TO 11B-308 FOR REACH RANGES MA N E U V E R I N G S P A C E 48 " M I N . 18" MIN. OPENING 32" MIN. CLR 17"-18" CLEAR FLOOR SPACE 60" MIN. 6" MAX. MA X . 12 " 59 " M I N @ F L R W C 56 " M I N . @ W A L L W C 17"-18" CLEAR FLOOR SPACE 60" MIN. 6" MAX. MA X . 12 " 59 " M I N . @ F L R W C 56 " M I N . @ W A L L W C 30" x 48" CLR SPACE 17"-19" 35" MIN.-37" MAX. SELF-CLOSING DOOR SELF- CLOSING DOOR 60 " M I N . OPENING 32" MIN. CLR. AMBULATORY TOILET STALL AT MULTIPLE ACCOMMODATION TOILET ROOM W/ 6 OR MORE STALLS 11B-604.8.2 SINGLE OCCUPANT TOILET 11B-603 17 " - 2 5 " MA X . 19 " . ℄ T U R NI N G S P A C E 6 0" MI N. 42" MIN. GRAB BAR 36" MIN. GRAB BAR MA N E U V E R I N G S P A C E 60 " M I N . SIDE-OPENING TOILET STALL OUT-SWINGING DOOR 11B-604.8.1.1.2 OP E N I N G 34 " M I N . C L R . SELF-CLOSING DOOR 17"-18" CLEAR FLOOR SPACE 60" MIN. 6" MAX. MA X . 12 " 59 " M I N . @ F L R W C 56 " M I N . @ W A L L W C MA N E U V E R I N G S P A C E 60 " M I N . SIDE-OPENING TOILET STALL IN-SWINGING DOOR 11B-604.8.1.1.2 SELF-CLOSING DOOR @ I N - S W I N G 36 " M I N . DO O R 4" M A X . 4" M A X . 17"-18" CLEAR FLOOR SPACE 60" MIN. 6" MAX. MA X . 12 " 59 " M I N . @ F L R W C 56 " M I N . @ W A L L W C END-OPENING TOILET STALL OUT-SWINGING DOOR 11B-604.8.1.1.3 17"-18" CLEAR FLOOR SPACE 60" MIN. 6" MAX. MA X . 12 " 59 " M I N . @ F L R W C 56 " M I N . @ W A L L W C END-OPENING TOILET STALL IN-SWINGING DOOR 11B-604.8.1.1.3 SELF-CLOSING DOOR @ I N - SW I N G I N G DO O R SELF-CLOSING DOOROPENING 32" MIN. CLR. 48 " M I N . MA N E U V E R I N G SP A C E 4" MAX. 42" MIN. GRAB BAR 36" MIN. GRAB BAR 42" MIN. GRAB BAR 36" MIN. GRAB BAR 42" MIN. GRAB BAR 36" MIN. GRAB BAR 36 " M I N . 48 " M I N . MA N E U V E R I N G SP A C E 4" MAX. OPENING 32" MIN. CLR. 42" MIN. GRAB BAR 36" MIN. GRAB BAR ELEVATION ADULT MI N . 9" PARTITION 6" MIN. COMPARTMENT TOE CLEARANCE 11B-604.8.1.4 TO O B S T R U C T I O N S 42 " M I N . C L R . OP E N I N G 34 " M I N . C L R CLEAR 18" MIN MIN 12" MA X . 12 " GR A B B A R 42 " M I N . CLEARANCE 6" MIN. TOE CLEARANCE 6" MIN. TOE CLEARANCE 6" MIN. TOE CLEARANCE 6" MIN. TOE 54 " M I N . 11B-604.8.1.2 11B-604.8.1.2 NOTE: 1. DIMENSIONS SHOWN DESCRIBE MINIMUM REQUIREMENTS ONLY, REFER TO CONSTRUCTION DOCUMENTS FOR SIZE & LOCATIONS OF SPECIFIC FIXTURES & ACCESSORIES. 2. PER 11B-604.6 FLUSH CONTROLS. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH SECT. 11B-309 EXCEPT THEY SHALL BE LOCATED 44" MAX. ABOVE THE FLOOR. CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET EXCEPT IN AMBULATORY ACCESSIBLE TOILET COMPARTMENTS COMPLYING WITH SECT.11B-604.8.2. 3. PER 11B-604.8.1.4 TOE CLEARANCE AT WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS. AT LEAST ONE SIDE PARTITION SHALL PROVIDE A TOE CLEARANCE OF 9" MIN. ABOVE THE FLOOR AND 6" DEEP MIN. BEYOND THE COMPARTMENT SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS. PARTITION COMPONENTS AT TOE CLEARANCES SHALL BE SMOOTH WITHOUT SHARP EDGES OR ABRASIVE SURFACES. EXCEPTION: TOE CLEARANCE AT THE SIDE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 66" WIDE. 4. PER 11B-604.8.2.2 TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH SECT. 11B-404, EXCEPT THAT IF THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 44" MIN. THE DOOR SHALL BE SELF-CLOSING. A DOOR PULL COMPLYING WITH SECT. 11B-404.2.7 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE MINIMUM REQUIRED COMPARTMENT AREA. 5. GRAB BARS SHALL COMPLY WITH SECT. 11B-609. A SIDE-WALL GRAB BAR COMPLYING WITH SECT. 11B-604.5.1. SHALL BE PROVIDED ON BOTH SIDES OF THE COMPARTMENT. T U R NI N G S P A C E 6 0" MI N. CL E A R 34 " M I N . FLOOR SPACE 60" MIN. CLR. 17"-18" . CL E A R A N C E 60 " M I N . 12 " M A X . GR A B B A R 42 " M I N . GRAB BAR 36" MIN. C L E A R 4 4 " M I N . 30" X 48" CLEAR CL E A R 44 " M I N . CL E A R 48 " M I N . CLEAR 32" MIN. MIN. 18". LEVEL & SLIP- RESISTANT FLOOR SURFACE, TYP. SELF-CLOSING DOOR 12" MIN.@ IN- SWING DOOR 18" MIN. @ OUT- SWING DOOR . FLUSH ACTIVATOR ON WIDE SIDE 56 " M I N . @ W A L L - M O U N T W C 59 " M I N . @ F L O O R - M O U N T W C 4" M A X . NOTE: REFER TO 11B-213.3.1 AND 11B-604.8 FOR TOILET COMPARTMENT REQUIREMENTS. NOTE: PROVIDE CONCEALED SOLID BLOCKING / BACKING FOR MOUNTING ATTACHMENTS. FIN. FACE OF WALL 11B-609.3 PROJECTING OBJECTS 1-1/4" MIN. TO 1-1/2" MAX. DIAMTER CLR 1 1/2" CL E A R 12 " M I N . MI N . 1 1 / 2 " 33" - 36" A.F.F. T.O. GRAB BAR PROJECTING OBJECTS, WHERE OCCURS 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 2 1 A M G4.d BARRIER FREE REQUIREMENTS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SCALE: NTS G4 . d1ACCESSIBLE WATER CLOSET AND TOILET ROOM COMPONENT MOUNTING HEIGHTS SCALE: NTS G4 . d2TOILET STALL REQUIREMENTS SCALE: NTS G4 . d4MULTI-ACCOMODATION TOILETS SCALE: NTS G4 . d8GRAB BAR CLEARANCES NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 ELEVATION PLAN SHOWER COMPARTMENT ENTRY FRONT ELEVATION PLAN 17 " - 1 9 " 11B-610.2 ACCESSIBLE BATHTUB SEAT11B-610.3.1 RECTANGULAR SHOWER SEAT 11B-610.3.2 L-SHAPED SHOWER SEAT 15 " - 1 6 " MAX. 1 1/2" 3" MAX. MA X . 2 1 / 2 " 15 " - 1 6 " PLAN MAX. 1 1/2" 3" MAX. 15 " - 1 6 " 17 " - 1 9 " SHOWER COMPARTMENT ENTRY FIN. FACE OF WALL FOLDED POSITION MA X . 2 1 / 2 " 14" - 15" 22 " - 2 3 " MAX. 6" SIDE ELEVATION 11B-607.4.2.1 -ELEVATION - BACK WALL 11B-607.4.2.3 -ELEVATION - HEAD END WALL REMOVABLE IN-TUB SEAT 11B-607.4.2 - TYPICAL PLAN 30 " M I N . LENGTH OF TUB 48 " M I N PA R A L L E L AP P R O A C H FO R W A R D AP P R O A C H BACK WALL HE A D WA L L CO N T R O L WA L L T. O . G R A B B A R 33 " - 3 6 " 17 " - 1 9 " T. O . G R A B B A R 33 " - 3 6 " MAX. 12" 24" MIN. MAX. 24" T. O . G R A B B A R 33 " - 3 6 " TUB SPOUT T. O . H A N D H E L D 48 " M A X . 11B-607.4.2.2 - ELEVATION - CONTROL END WALL TUB/SHOWER VALVE 3- WAY DIVERTER FLEXIBLE SHOWER SPRAY HOSE 59" LONG MIN. MOUNTING BRACKET & SHOWER SPRAY UNIT FIXED SHOWER HEAD CONTROLS & OPERABLE PARTS ZONE 24" MIN. GRAB BAR ALIGN WITH FRONT EDGE OF TUB. 1-1/2" MIN. CLEAR ABOVE AND BELOW ℄ T. O . B A R 8" - 1 0 " TOE TAP DRAIN OF BATH TUB 24 " M I N . 12" MAX.24" MIN.24" MAX. MI N . 12 " ELEVATION - BACK WALLELEVATION - LEFT SIDE ELEVATION -RIGHT SIDE T. O . G R A B B A R 33 " - 3 6 " 30" MIN. 11B-608.2.2 -PLAN - STANDARD ROLL-IN SHOWER CLEAR 60" MIN. CL E A R 36 " M I N . BACK WALL SI D E W A L L SI D E WA L L 30 " M I N . FOLDING SHOWER SEAT 6" MAX. 6" M A X . SEAT 22"-23" FACE OF FINISH ℄ 30" MIN. FACE OF FINISH 17 " - 1 9 " T. O . G R A B B A R 33 " - 3 6 " FOLDING SHOWER SEAT FLEXIBLE SHOWER SPRAY HOSE 59" LONG MIN. MOUNTING BRACKET & SHOWER SPRAY UNITCONTROLS & OPERABLE PARTS ZONE T. O . G R A B B A R 33 " - 3 6 " 16" MIN. 27" MAX. FIXED SHOWER HEAD 38 " M I N . FIXED SHOWER HEAD SHOWER VALVE & DIVERTERSOAP DISH 40" MAX. A.F.F. FACE OF FINISH 60" MIN. 48 " M A X . 11B-608.3.3 - PLAN - ALTERNATE ROLL-IN SHOWER BACK WALL SI D E W A L L SI D E W A L L FRONT WALL 36 " M I N . 60" MIN. MAX. 6" MAX. 6" ELEVATION - BACK WALLELEVATION - FRONT WALL ELEVATION - LEFT SIDE T. O . G R A B B A R 33 " - 3 6 " 36" MIN. FACE OF FINISH ℄ SE A T 17 " - 1 9 " FOLDING SHOWER SEAT FLEXIBLE SHOWER SPRAY HOSE 59" LONG MIN. MOUNTING BRACKET & SHOWER SPRAY UNITCONTROLS & OPERABLE PARTS ZONE T. O . G R A B B A R 33 " - 3 6 " 48 " M A X . FIXED SHOWER HEAD FACE OF FINISH 60" MIN. CLR OPENING 36" MIN. FACE OF FINISH 60" MIN. CLR OPENING 36" MIN. 16" MIN. 27" MAX. MA X . 6" SE A T 17 " - 1 9 " 48 " M A X . FIXED SHOWER HEAD ℄ MAX. 15" OF SEAT SHOWER VALVE & DIVERTER 38 " M I N . 38 " M I N . BACK WALL HE A D WA L L CO N T R O L WA L L 36" 36 " CL E A R 36 " M I N . CLEAR 48" MIN. 11B-608.2.1 - PLAN - TRANSFER SHOWER MIN. 18" ELEVATION - LEFT SIDE ELEVATION - CONTROL WALL T. O . G R A B B A R 33 " - 3 6 " 36" FACE OF FINISH ℄OF SEAT MAX. 15" 48 " M A X . CONTROLS & OPERABLE PARTS ZONE FIXED SHOWER HEAD T. O . G R A B B A R 33 " - 3 6 " SE A T 17 " - 1 9 " FOLDING SHOWER SEAT 36" FACE OF FINISH 36" FACE OF FINISH SE A T 17 " - 1 9 " ELEVATION - BACK SIDE MOUNTING BRACKET & SHOWER SPRAY UNIT SHOWER VALVE & DIVERTER LOCATION OF ACC. HEIGHT SHOWER BASKET. 15" MIN. AFF. 1.5" CLEAR TO BOTTOM OF GRAB BAR 38 " M I N . 7" CLEAR A.F.F. FOR LIFTING DEVICE. 12" MAX. FROM HEAD WALL AND FROM FOOT END OF THE BED MANEUVERING SPACE SINGLE BEDDOUBLE BED 7" CLEAR A.F.F. FOR LIFTING DEVICE. 12" MAX. FROM HEAD WALL AND FROM FOOT END OF THE BED MANEUVERING SPACE 12" MAX.12" MAX. MANEUVERING SPACE CL E A R 36 " M I N . 12" MAX.12" MAX. 7" CLEAR A.F.F. FOR LIFTING DEVICE. 12" MAX. FROM HEAD WALL AND FROM FOOT END OF THE BED PATH 36" MIN. CLEAR 48" MIN. CLEAR 48" MIN. CLEAR 48" MIN. PATH 36" MIN. 30 " M I N . 30 " M I N . CL E A R 36 " M I N . 30 " M I N . 30 " M I N . CL E A R 36 " M I N . 12" MAX. ONE BEDROOM DIAGRAM STUDIO DIAGRAM TWO BEDROOM DIAGRAM 1 3 2 4 2 4 SYMBOL DEVICE NOTES 1 BUTTON FOR DOOR SIGNAL OUTSIDE DOOR ON STRIKE SIDE, +46" AFF TO FACTORY LABEL ON COVER PLATE 2 2-GANG BOX W/ TRANSFORMER FOR DOOR BELL MOUNT TRANSFORMER IN SOFFIT OR CABINET AND PROVIDE ACCESS 3 DOORBELL DISABLE SWITCH WALL BEHIND ENTRY DOOR, NEAR LIGHT SWITCH "DOORBELL DISABLE SWITCH" PLAQUE 4 SMOKE STROBE, REMOTE COMPATIBLE WITH SMOKE DETECTOR, BATHROOM +80 AFF "SMOKE" LABEL INTEGRAL TO DEVICE (d) DEVICES FOR COMMUNICATION FEATURES NOTES: 1. PLAN DIAGRAM SHOWS GENERAL CONFIGURATION OF DOORBELL DEVICES - DESIGNER TO MODIFY AS REQUIRED FOR ACTUAL GUESTROOM CONFIGURATION AND LOCAL REQUIREMENTS. 2. PLAQUES (EXCEPT AS NOTE): PROVIDE AS REQUIRED; PLAQUES SHALL BE BLACK PHENOLIC WITH 1/4" WHITE ENGRAVED LETTERS. 3. LOCATE DOORBELL DISABLE SWITCH NEXT TO WELCOME LIGHT SWITCH -DO NOT GANG BOX. PROVIDE SEPARATE LABELED COVER PLATE (TYPICAL) 4. NFPA 18.5.4.7.3 FOR ROOMS WITH A LINEAR DIMENSION GREATER THAN 16 FT., THE VISIBLE NOTIFICATION APPLIANCE SHOULD BE LOCATED 16 FT. OF THE PILLOW. 5. REFER TO 11B-224.4 AND 11B-806.3 FOR GUEST ROOMS WITH COMMUNICATION FEATURES. 6. REFER TO 11B-224.5 FOR DISPERSION OF COMMUNICATION ROOMS. 1 3 1 3 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 2 3 A M G4.e BARRIER FREE REQUIREMENTS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SCALE: NTS G4 . e1BATHTUB AND SHOWER SEAT REQUIREMENTS SCALE: NTS G4 . e2ACCESSIBLE BATHTUB REQUIREMENTS SCALE: NTS G4 . e3ACCESSIBLE ROLL-IN SHOWER REQUIREMENTS SCALE: NTS G4 . e4ACCESSIBLE ALTERNATE ROLL-IN SHOWER REQUIREMENTS SCALE: NTS G4 . e5ACCESSIBLE TRANSFER SHOWER REQUIREMENTS SCALE: NTS G4 . e6BED MANEUVERING CLEARANCES SCALE: 1/4" = 1'-0"G4 . e7COMMUNICATION DEVICE LOCATION DIAGRAM NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 FLOOR AREA 30" MIN. CLR. FLOOR AREA 30" MIN. CLR. ST A N D I N G P E R S O N 38 " M I N . - 4 3 " M A X . SP O U T O U T L E T 36 " M A X . T O NOTES: 1. REFER TO 11B-211 FOR DRINKING FOUNTAINS AND BOTTLE-FILLING STATION REQUIREMENTS. 2. ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. 3. WHEN LOCATED WITHIN THE COMMON PATH OF TRAVEL, LEADING EDGE OF BOTH ACCESSIBLE AND STANDARD DRINKING FOUNTAINS MUST BE A MAXIMUM OF 27" AFF TO BE IN COMPLIANCE WITH ACCESSIBILITY CANE DETECTION REQUIREMENTS. 4. PUSH BUTTON MUST BE WITHIN REACH RANGE AND ACTIVATION SHALL NOT REQUIRE TIGHT GRASPING OR PINCHING. SP O U T O U T L E T 36 " M A X . T O 4" M I N . 4" M I N . WA T E R ST R E A M WA T E R ST R E A M SP O U T O U T L E T 36 " M A X . T O 27 " M I N . 19" MAX. 18" MIN. 4" M I N . WA T E R ST R E A M MIN. 8" MIN. 11" 9" M I N . 36 " M I N . @ A L C O V E 32 " M I N @ A L C O V E 30 " M I N . C L E A R 48" MIN. CLEAR ALCOVE DEPTH 18" MIN. DE P T H ≤ 24 " DE P T H > 2 4 " 5 MAX.15" MIN. SPOUT . EL E C T R O N I C S E N S O R 47 " M A X . BOTTLE FILLING STATION PERMITTED TO SUBSTITUTE 50% OF DRINKING FOUNTAINS REQUIREMENTS 30" MIN. x 48" MIN. PARALLEL APPROACH FLOOR CLEARANCE ℄ 11B-804.2.1 -PUBLIC DWELLING - PASS THROUGH KITCHEN 11B-804.2.2 - PUBLIC DWELLING - "U" SHAPE KITCHEN BETWEEN FACE OF 60" MIN. CLR. BETWEEN FACE OF 48" MIN. CLR. CABINETS, FIXTURES, OR APPLIANCES WO R K S U R F A C E 30 " M I N . KN E E & T O E 30 " M I N . C L R . CL E A R A N C E COUNTER 24" MAX. COUNTER 24" MAX. 11B-804.2.2 -PUBLIC & HOUSING - "U" SHAPED KITCHEN WITH PARALLEL APPROACH CLEARANCE AT THE BASE BETWEEN FACE OF 60" MIN. CLR. 11A-1133A -HOUSING - "U" SHAPED KITCHEN WITH FORWARD APPROACH CLEARANCE AT THE BASE CABINETS, FIXTURES, OR APPLIANCES COUNTER 24" MAX. COUNTER 24" MAX. WO R K S U R F A C E 30 " M I N . D/W KNEE & TOE 30" MIN. CLEARANCE REF. NOTES: 1. 30" MIN. COUNTERTOP SPACE FOR SINK INSTALLATION WITH REMOVEABLE BASE CABINET AND FINISH FLOORING BENEATH THE SINK; 30" x 48" MIN. CLEAR FLOOR SPACE TO ALLOW FORWARD APPROACH. 2. 30" MIN. COUNTERTOP FOR WORK SURFACE WITH REMOVABLE BASE CABINET AND FINISH FLOORING BENEATH; 30" x 48" MIN. CLEAR FLOOR SPACE TO ALLOW FORWARD APPROACH. 3. 30" x 48" MIN. CLEAR FLOOR SPACE ADJACENT TO RANGE TO ALLOW PARALLEL APPROACH 4. CENTERLINE OF 30" x 48" MIN. CLEAR FLOOR SPACE ALIGNED WITH CENTERLINE OF REFRIGERATOR, DISHWASHER, TRASH COMPACTOR OR OTHER APPLIANCES TO ALLOW PARALLEL OR FORWARD APPROACH. 5. AT LEAST 50% OF STORAGE SHELF SPACE IN PUBLIC DWELLING KITCHENS SHALL COMPLY WITH AT LEAST ONE OF THE REACH RANGES. 1 CABINETS, FIXTURES, OR APPLIANCES D/W REF. D/W REF. COUNTER 24" MAX.COUNTER 24" MAX. WO R K S U R F A C E 30 " M I N . KN E E & T O E 30 " M I N . CL E A R A N C E 11A-1133A -HOUSING - TYPICAL KITCHEN BETWEEN FACE OF 48" MIN. CLR. CABINETS, FIXTURES, OR APPLIANCES WO R K S U R F A C E 30 " M I N . KN E E & T O E 30 " M I N . C L R . CL E A R A N C E COUNTER 24" MAX. COUNTER 24" MAX. D/W REF. 2 3 BETWEEN FACE OF 40" MIN. CLR. WO R K S U R F A C E 30 " M I N . KN E E & T O E 30 " M I N . C L R REF. D/W CABINETS, FIXTURES, OR APPLIANCES CL E A R A N C E 1 1 1 1 2 2 2 2 3 3 3 3 LAUNDRY SHELVING 15 " - 3 6 " 36 " M A X . 40 " M I N . - 4 8 M A X . GUEST LAUNDRY WASHER & DRYER REFER TO 11B-611 FOR WASHING MACHINES AND CLOTHES DRYERS REQUIREMENTS. 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 2 4 A M G4.f BARRIER FREE REQUIREMENTS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SCALE: NTS G4 . f1DRINKING FOUNTAIN & BOTTLE FILLING STATION SCALE: NTS G4 . f2ACCESSIBLE KITCHEN LAYOUTS SCALE: NTS G4 . f9ACCESSIBLE LAUNDRY NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 1. AUTOMATIC CLOSING (MAGNETIC HOLD OPEN) AND CONNECTED TO FIRE ALARM/SPRINKLER SYSTEM 2. DOORS TO HAVE 10" FLUSH BOTTOM 3. AUTOMATIC SLIDER TO PROVIDE FULL BREAKOUT 4. ALL GUESTROOM ENTRY DOORS TO HAVE WELDED FRAMES 5. ALL (N) EXTERIOR DOORS AND FRAMES TO BE PAINTED COLOR MATCHING THAT OF THE ADJACENT WALL FINISHES 6. AUTOMATIC DOOR OPENER (RECESSED FLOOR MOUNTED) 7. CR DOOR SCHEDULE NOTES 8. CR AND REMOTE RELEASE 9. EXTERIOR FINISH TO MATCH ADJACENT EXTERIOR WALL COLOR. 10. GLAZED IN LOUVER ABOVE LOUVER DOOR. 1" FLANGE GLAZED IN TO STOREFRONT. 11. DOOR WITH MULLIONS PER I.D. 12.CBC 1010.2.4.3 3.1 THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED. 3.2 A READILY VISIBLE DURABLE SIGN IS POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED. THE SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A CONTRASTING BACKGROUND. 3.3 THE USE OF THE KEY-OPERATED LOCKING DEVICE IS REVOCABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE. SHEET NOTES A. DOOR HARDWARE TO BE PROVIDED BY THE DOOR MANUFACTURER B. REFER TO SPECS FOR DOOR HARDWARE GROUPS. DOOR HARDWARE SHALL COMPLY WITH DISABLED ACCESS REQUIREMENTS AS REQUIRED (CBC 11B-404.2.7 AND 11B-309.4) C. SLIDING DOORS COMPLY WITH CBC 1010.1.4.3 D. ADDITIONAL SMOKE AND DRAFT CONTROL AT ELEVATOR SERVICE LOBBY DOORS & PASSENGER ELEVATOR DOORS PER CBC 3006.3.3. CBC 3006.3.5 AT BASEMENT & SECOND THROUGH EIGHTH FLOORS. E. POWER OPERATED DOORS SHALL BE CAPABLE OF BEING MANUALLY OPENED TO PERMIT EXIT TRAVEL IN THE EVENT OF A POWER FAILURE. (CBC 1010.1.4.2). SEE DOOR HARDWARE SCHEDULE. F. LANDINGS OR FLOOR LEVEL AT DOORS SHALL NOT BE MORE THAN 1/2" BELOW THE THRESHOLD. RAISED THRESHOLDS GREATER THAN 1/4" AT DOORWAYS SHALL BE BELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL. (CBC 11B-404.2.5). SEE 10/G4.A AND A1. G. REFER TO I.D. DRAWINGS FOR INTERIOR DOOR STYLE DESIGNS OF PUBLIC AREA. FIRE RATINGS NR NON-RATED 20 20 MINUTE FIRE RATED 45 45 MINUTE FIRE RATED 60 60 MINUTE FIRE RATED 90 90 MINUTE FIRE RATED DOOR CONSTRUCTION ALL TYPES ARE TYPICAL AS SPECIFIED EXCEPT WHERE ADDITIONAL TYPES ARE NOTED. SC WOOD -FLUSHSOLID CORE HC WOOD -FLUSH HOLLOW CORE SR WOOD -STILE & RAIL HM HOLLOW METAL KD KNOCK DOWN FRAME MC METAL -COILING ABBREVIATIONS AL ALUMINUM ASR ALUMINUM -STILE & RAIL ALF ALUMINUM -FLUSH AFI ALUMINUM -FLUSH INSULATED GL GLASS STL STEEL FRAME CONSTRUCTION ALL TYPES ARE TYPICAL AS SPECIFIED EXCEPT WHERE ADDITIONAL TYPES ARE NOTED. WD SOLID WOOD HM HOLLOW METAL AL ALUMINUM STL STEEL DOOR OR FRAME FINISH PT PAINTED -OPAQUE ANO ANODIZED SST STAINLESS STEEL PL PLASTIC LAMINATE CSF CUSTOM STEEL FINISH GLAZING TYPE GLAZING TYPES ARE PER TYPICAL TYPES SPECIFIED IN SPECIFICATION AND FINISH SCHEDULE UNLESS INDICATED OTHERWISE. TGT TRANSLUCENT TEMPERED SAFETY GLASS TSG TEMPERED SAFETY GLASS WG CLEAR WIRE GLASS -RATING AS NOTED SG SPANDREL GLASS LG LAMINATED GLASS IGU LAMINATED INSULATED SAFETY GLASS UNIT HARDWARE CR CARD READER (WALL MOUNTED) PROVIDE LOW VOLTAGE WIRING TO DOOR CRL CARD READER LOCK (RFID HOTEL LOCK WITH BLUETOOTH LOW ENERGY (BLE)-BATTERY POWER SELF-CONTAINED PH PANIC HARDWARE C0 WOOD FLUSH BARN DOOR F1 (E) GLASS DOOR (C164.1 & C166.1), UNDER SEPARATE PERMIT FOR REFERENCE ONLY) FINISHED FLOOR WOOD PIVOT DOOR A9 3' - 1 3/4"CL OF PIVOT PANIC BAR, W.O. E1 10 " M I N . 5"5" 8"5" FINISHED FLOOR (E) ALUMINUM DOOR (C165.1), UNDER SEPARATE PERMIT FOR REFERENCE ONLY) ACT -ACOUSTIC CEILING TILE CONC. -CONCRETE CPT -CARPET CT -CERAMIC TILE OR PORCELAIN TILE EPY -EPOXY COATING FRP -FIBERGLASS REINFORCED PLASTIC GW -GREEN WALL PT -PAINT QT -QUARRY TILE RB -RUBBER BASE RF -RUBBER FLOORING SC -SEALED CONCRETE ST -STONE TILE VINYL -VINYL VRF -VINYL RESILIENT FLOORING WC -WALL COVERING WD -WOOD ACT-1 BACK OF HOUSE/OFFICES SIZE: 24”X24”x3/4”EDGE SHADOWLINE MFG: USG INTERIORS COLOR: STANDARD WHITE ACT-1 BACK OF HOUSE/OFFICES SIZE: 24”X24”x3/4”EDGE SHADOWLINE MFG: USG INTERIORS COLOR: STANDARD WHITE ACT-4 BACK OF HOUSE SIZE: 24”X48”x3/4”EDGE SHADOWLINE MFG: USG INTERIORS COLOR: STANDARD WHITE ACT-2 KITCHEN SIZE: 24”X48”X15/16”SQUARE LAY-IN MFG: ARMSTRONG “KITCHEN ZONE”KITCHEN ZONE ITEM #672 COLOR: WHITE GRID: 15/16”PRELUDE EXPOSED T SYSTEM ACT-ACOUSTIC CEILING TILE ACT-3 LOBBY SIZE: 96”X24”X” MFG: ARMSTRONG METALWORKS LINEAR COLOR: GRID: FRP WALL PANEL, WHERE OCCURS SEALANT BEHIND METAL STRIP FLOOR SLAB FINISH SEAL COAT 4" EPOXY COATING METAL CAP STRIP TROWELED EPOXY BASE W/ 5/8" RADIUS CL PER PLAN WALL TYPES CONT. SEALANT TYP. CEMENTITIOUS BACKER BOARD AT TILE CERAMIC TILE ON THINSET ANODIZED ALUMINUM 3/8" RADIUS PROFILE, BY SCHLUTER OR EQUAL FLOOR SLAB CL PER PLAN WALL TYPE CONT. SEALANT TYP. FRAMED OPENING PER STRUCTURAL DESIGNER 2" LINE WHERE WALL OCCURS HOLLOW METAL FRAME VA R I E S 2"5/8" 2" MIN. 4"FRAME OPENING PROVIDE BATT INSUL. AT GUESTROOM ENTRY AND MEETING ROOM DOORS SE E F L O O R P L A N S F O R R E F E R E N C E WA L L T Y P E 1/ 2 " 1/ 2 " HOLLOW METAL DOOR FRAME ANCHOR CLIP 2"2" 2" PROVIDE DOOR HEADER AS REQ'D 5/ 8 " VARIES 1/2"1/2" SEE FLOOR PLANS FOR REFERENCE WALL TYPE 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 2 8 A M A1 DOOR SCHEDULES AND DOOR TYPES (TI) HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT DOOR SCHEDULE - TI NU M B E R LOCATION DOOR INFORMATION FRAME INFORM ATION RATING S HARDWARE DOOR NOTESFROM ROOM TO ROOM TY P E WI D T H HE I G H T TH I C K N E S S DO O R M A T E R I A L FR A M E M A T E R I A L FI R E R A T I N G PA N I C H D W R . MA G . H O L D O P E N CL O S E R HARDWARE # BLDG. C & D LEVEL 1 C164 JAPANESE RESTAURANT DINING HALLWAY A9 4' - 0" 8' - 0" 2 1/2" SC WD - - - 70.2 C164.1 JAPANESE RESTAURANT DINING F1 2' - 11 7/8" 8' - 0" 3/8" GL AL PH - CL 67.0 DOOR NOTE 7 C165.1 JAPANESE RESTAURANT KITCHEN E1 3' - 0" 8' - 0" 1 3/4" AL AL 0 - - CL 62.1 SEE A0.21 FOR TRANSOM C166 JAPANESE RESTAURANT DINING JAPANESE RESTAURANT V.I.P. SEATING C0 4' - 0" 9' - 9" 1 3/4" SC - - - - 71.5 C166.1 JAPANESE RESTAURANT V.I.P. SEATING F1 3' - 1 1/8" 8' - 0" 3/8" GL AL PH - CL 67 DOOR NOTE 7 SCALE: 3/8" = 1'-0" DOOR TYPES SCALE: 12" = 1'-0" ROOM FINISH ABBREVIATIONS SCALE: 1/8" = 1'-0" ACT CEILING TYPES SCALE: 3" = 1'-0" A11EPOXY BASE DETAIL SCALE: 3" = 1'-0" A12TILE BASE DETAIL SCALE: 3" = 1'-0" A13COVE BASE DETAIL SCALE: 3" = 1'-0" A14HM FRAME JAMB DETAIL SCALE: 3" = 1'-0" A15HM FRAME HEAD DETAIL (E) DOOR, UNDER SEPARATE PERMIT (E) DOOR, UNDER SEPARATE PERMIT (E) DOOR, UNDER SEPARATE PERMIT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET DOOR NOTE 12 C-18505NO. REN.09/30/27 FP (E) PARKING GARAGE BUILDING B SS SS W W W FP FP 4 Y D TRA S H 4 Y D TR A S H 4 Y D TRA S H 4 Y D TR A S H 4 Y D TRA S H 4 Y D TR A S H 4 Y D TRA S H 4 Y D TR A S H EDISONUTILITIES 1" : 12"MAX DN 1" : 12" DN 1" : 12"DN 1" : 12"DN LEFTTURNONLY GM SLPB SLPB CONC SIDEWALK VISIBILIT Y T RIA N G LE 30' H U N T I N G T O N D R . SAN RAFAEL ROAD HUNTINGTON DR. COLORADO PLACE C LEAN AIR VECHICLE CLEAN AIR VECHIC LE C LEAN AIR VECHIC LE CL EAN AIR V ECHIC LE CL E AN AIR V ECHIC LE CLEAN AIR VECHIC LE C LEAN AIR VEC HIC LE CL E AN AIR V EC HICL E CL E AN AIR V ECHICLE C LE A N AIR V E C HICL E C LE A N AIR VE C HICL E C LE A N AIR V E C HICL E D N HOISTWAY PLAN O P E N A I R V E N T HS SELECT. S SLOPE SLOPE SLOPE SLOPE W STOP STOP STOP STOPSTOP STOP 0 8.07.23 PRO G RESSSET SIDEWALK PLANTER SIDEWALK BIKE PARKING LOADING POOL 18' 6" X 40' COURTYARD (EGRESS COURT) TERRACE BUILDING D NEW 6-STORY BUILDING F.F.E. 476.60' BUILDING C EXISTING 3-STORY BUILDING TO BE RENOVATED F.F.E. 476.60' CANOPY ABOVE OUTDOOR PATIO PORTE COCHERE PLANTER SIDEWALK PARKING OVERHANG, TYP. PLANTER S 1 S 2 S 3 S 4 S 5 S 6 S 7 S 8 S 9 S 10 S 11 S 12 S 13 S 14 S 15 EV 17 EV 18 EV 19 EV 20 EV 21 EV 22 EV 23 EV 24 EV 25 EV 26 S 27 EV 34 EV 33 EV 32 EV 31 EV 30 EV 29 S 28 S 40 S 39 S 38 S 37 EV 36 S 35 ACC VAN 46 ACC 45 ACC 44 ACC EV VAN 43 ACC EV 42 S 41 (APPROX. SIZE 143"X 50.4" X 91.7" HIGH) (E) GENERATOR 3.1 3.3 3.7 3.7 3.7 5.24 3.2 32.23.1 3.33.1 3.3 33.3 32.8 33.7 33.5 33.6 33.8 33.8 33.8 33.6 S 16 TERRACE 33.1033.11 33.6 LINE OF EASEMENT 2.09 A1.22 1A1.22 9 BL D G . D BL D G . C 3.1 3.29 3.4 3.1 33.7 3.4 3.1 3.4 26.18 26.182.28 26.36 3.5 3.5 3.5 2.10 2.10 32.1132.11 3.30 4.3 4.2 5.255.25 4.34.3 4.3 5.25 4.4 4.2 5.25 30' - 0" 45' - 3" 40' - 8 1/2" IMAGINARY PROPERTY LINE BETWEEN BLDG C AND (E) PARKING GARAGE IMAGINARY PROPERTY LINE BETWEEN BLDG C AND (E) BUILDING B 13.1 13.6 A1.11 6 A1.11 3 A1.11 5 A1.11 4 A1.11 1 A1.11 2 26.16 32.14 32.5 32.14 32.14 32.11 S 47 S 48 32.932.932.9 1' - 4 3/4" (478')2 2 ' - 2 3 / 8 " 37' - 1 1/4" BIKE PARKING A1.11 7 CLEAN AIR/ VANPOOL/EV CLEAN AIR/ VANPOOL 22.22 32.2 32.2 32.2 32.2 32.2 21.3 A1.11 8 476.3' 476.78' 11.5 12.5 D C.4 C 12 10.23 10.24 12'X12' VIEW TRIANGLE, NO TALL PLANTING TO OBSTRUCT VIEW 3.42 STANDARD PARKING STALL SIZE 9'-0"X18'-0" TYP. REFER TO 2/A1.01 FOR REQUIREMENTS. 12' -6" MIN. CLR 13' - 5 3/4" MIN. CLR 25' - 0" 3.1 3.4 3.1 3.4 3.1 3.4 1 2 ' - 6 " M I N . C L R 1 6 ' - 5 3 / 4 " FLEXIBLE DELINEATOR ROUND POST WITH BASE TYP., ULINE H-4465W OR SIMILAR CLR 12'-6" MIN. 2 5 ' - 0 " R 1 0 ' - 0 " 5' - 11 1/2" 18' - 0" 25' - 0 1/2" 40' - 0" 25' - 2 1/4" R 5' - 0 " R 3 ' - 0 " 44' - 3 3/8" 64' - 10 1/2" R 54' - 5" R 25' - 0" R 14' - 7 3/ 4" R 1' - 6 " R 1' - 6 3/8" 4' - 10 3/4" 4' - 2 1/4" R 2 5 ' - 0 " 25' - 6" 30' - 10 1/8" 3' - 5 7/8" 24' - 0" 11' - 9 1/2" 15' - 9 3/4" R 13' - 9" 16' - 5 1/4" R 3 ' - 0 " 17 ' - 0 " 2 5 ' - 0 " 6 ' - 0 1 / 2 " R 3' - 0"R 3 ' - 0 "R 3' - 0" R 3 ' - 0 " R 60' - 0" R 3' - 0 " R 3 ' - 0 " R 3' - 0 " R 3' - 6"R 3' - 0 " 32' - 1" CLR3' - 1" 9' - 0 1/8" 99' - 6" 72' - 6"90' - 0" 20' - 2 1/2" CL 2' - 4 1/2" 8' - 9 7/8" PLANTER 3' - 4" 30 ' - 0" 8' - 6" 17' - 0" 67' - 2 1/8" 15 ' - 1 0 " 4' - 9" 3' - 1 " 5' - 0 " 7' - 1 1 / 2 " 5 0 ' - 5 " 9' - 7 3 / 4 " 6' - 2" 2'-0" DOOR PULL SIDE CLEARANCE R 3 ' - 0 " R 20 ' - 0 " R 45' - 0 1/8" BUILDING HARDSCAPE AND SIDEWALK: S.C.D. AND S.L.D. LEGEND LANDSCAPE, S.L.D. 1. REFER TO CIVIL, LANDSCAPE DWGS FOR MORE INFORMATION. 2. REFER TO SITE LIGHTING DWG FOR PARKING LOT, POOL AND LANDSCAPE LIGHTING DESIGN. 3. PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES AND OPERABLE WINDOWS. PROVIDE NO SMOKING SIGNAGE WITHIN THESE AREAS. [CALGREEN 5.504.7] 4. AT HAZARDOUS VEHICULAR AREAS, DETECTABLE WARNING SURFACES SHALL BE YELLOW CONFORMING TO FS 33538 OF FEDERAL STANDARD 595C. SEE G0.34 FOR DETECTABLE WARNING DETAILS AND PROVIDE IN ALL REQUIRED LOCATIONS. SHEET NOTES 5. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL SURFACES SHALL BE INSTALLED [CBC SEC 11B-705.3] 6. REFER TO G0.01 FOR PARKING INFORMATION 7. REFER TO G0.33, G0.34, G0.35 FOR ACCESSIBLE NOTES AND REQUIREMENTS 8. EV CHARGING SPACES ARE FOR FUTURE USE, SEE ES1.01 AND G0.01. 9. EXISTING DETECTABLE WARNINGS TO REMAIN 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 5/ 1 3 / 2 0 2 5 5 : 4 6 : 2 9 P M A1.01 SITE PLAN HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. SCALE: 1" = 20'-0"A1 . 0 11SITE PLAN N KEYNOTES 2.09 (E) PME SWITCH: S.E.D. 2.10 (E) TRANSFORMER: S.E.D 2.28 EXISTING CITY / UTILITY VAULTS WHERE OCCURS TO REMAIN, PROTECT IN PLACE. S.C.D. 3.1 DETECTABLE WARNINGS MIN. 3'-0" WIDE. 3.2 WHEEL STOPS,TYP. 3.3 ZERO CURB AT ADA STALLS 3.4 ZERO CURB 3.5 S.L.D. FOR PAVING MATERIAL 3.7 LOADING 3.29 TRASH ENCLOSURE. PROVIDE LIGHITNG, HOSE CONNECTION AND DRAIN. 3.30 BENCH, S.L.D. 3.42 CONCRETE CURB/MEDIAN 4.2 6' HEIGHT CMU WALL, S.S.D. & S.L.D. 4.3 8' HEIGHT CMU WALL, S.S.D. & S.L.D. KEYNOTES 4.4 8' HEIGHT CMU WALL, S.S.D. 5.24 5 FEET HIGHT POOL FENCE, S.L.D. 5.25 METAL PANEL, S.L.D 10.23 PARKING COUNT SIGN, COORDINATE WITH SIGNAGE CONSULTANT/VENDOR 10.24 DO NOT ENTER SIGN, COORDINATE WITH SIGNAGE CONSULTANT/VENDOR 13.1 POOL, ACCESSORIES, & POOL LIFT UNDER SEPARATE PERMIT 13.6 FOR POOL EQUIPMENT ROOM, CONTRACTOR TO CONFIRM ANY HAZARDOUS MATERIALS STORED COMPLIED WITH CBC 307.1.1. IF ANY MATERIALS EXCEED THE REQUIREMENTS, CONTRACTOR MUST FILE WITH HAZARDOUS PROGRAM DIRECTOR. 21.3 FIRE DEPARTMENT CONNECTION KEYNOTES 22.22 HOSE BIB, S.P.D. 26.16 (N) TRANSFORMER: S.E.D. 26.18 (E) POWER POLE: S.E.D. 26.36 (N) NATURAL GAS STANDBY EMERGENCY GENERATOR: S.E.D. 32.2 PARKING LIGHTING STANDARDS. S.E.D. FOR LANDSCAPE LIGHTING 32.5 (N) LANDSCAPING, S.L.D. 32.8 STRIPED ACCESSIBLE PASSENGER LOADING ZONE & PATHWAY 32.9 BOLLARD: S.S.D. 32.11 FIRE PIT, S.I.D, S.L.D, S.P.D FOR MORE INFORMATION KEYNOTES 32.14 TREES, S.L.D., REFER TO L3.01 FOR (E) TREE SPECIES AND METHODS OF PROTECTION OR REMOVAL 33.3 WATER METER: S.C.D. 33.5 IRRIGATION METER: S.C.D. 33.6 (N) STORM DRAIN: S.C.D. 33.7 GREASE INTERCEPTOR: S.C.D. 33.8 BMP: S.C.D. 33.10 (N) FIRE HYDRANT: S.C.D. 33.11 (N) SEWER LATERAL: S.C.D. NO.DATE ISSUES & REVISIONS 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) 02.26.24 BULLETIN 5 07.29.24 BULLETIN 9 05.12.25 BULLETIN 13 SCALE:NTS A1 . 0 12STANDARD PAKRING REQUIREMENT 05/21/2025 CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________EP 05/21/2025 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T W W FP FP UTILITIES 1" : 12"DN 1" : 12" DN GM SLPB COLORADO PLACE O P E N A I R V E N T SLOPE SLOPE +24"~ 30" KITCHEN DISHWASHING UTILITYCABINET. CO2 18"x36" DN UP DN UP DN UP +18" +44" +18" +18" 7" 3'-2" 1'-4" 1'-4" 4'-9" UTILITYCABINET. UTILITYCABINET. 14" x 4 8 " 1 4 " x 4 8 " 14"x36" 14"x36" 14"x36" J NON-RATED WALL 1-HOUR FIRE PROTECTED WALL 1-HOUR RATED WALL 2-HOUR RATED WALL 2-HOUR FIRE PROTECTED WALL 3-HOUR RATED WALL 4-HOUR RATED WALL CONCRETE WALL CONCRETE MASONRY UNIT WALL WALL TYPES 1 A B C C.3 C.4 D 0.6 2 3 4 5 6 7 7 8 9 10 11 12 13 6.7 7.3 0.5 2.5 3.5 4.5 5.5 6.5 C.6 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 1.5 QQ C.3 ACC. TUB C 101 KING C.1 C 103 QQ C.1 C 105 KING C.1 C 107 KING C.1 C 109 QQ C.3 C 102 KING C.1 C 104 QQ C.1 C 106 KING C.1 C 108 KING C.1 C 110 QQ C.1 C 112 ADMIN C 145 I.T. ROOM C 142 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 8 3/4" 21 ' - 9 " 1 ' - 7 " 9 ' - 6 " 7 ' - 4 " 3 2 ' - 1 0 " 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 9' - 8" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 8 3/4" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 9' - 8" 32' - 10" 7' - 4" 9' - 6" 1' - 7" 21' - 9" STAIR ST-C2 STAIR ST-C1 ENTRY VESTIBULE C 148 BOH C 152 CORRIDOR C 100 STAIR ST-C3 ELEC. C 113 RESTAURANT DINING (THE OVALO) C 161 POOL EQUIP. D 004 FRONT DESK C 146 LOBBY C 149 EXECUTIVE LOUNGE C 147 BAR C 151 ELEV. #2 ELEV. #1 QQ C.1 C 111 LUGG./BIKE STORAGE C 141 (E) BIKE PARKING (E) LOADING TERRACE (E)CANOPY ABOVE PORTE COCHERE PLANTER PLANTER BAR LOUNGE C 150 WALKWAY C 153 OUTDOOR LOUNGE D 120 POOL DECK D 123 POOL D 124 RISER ROOM C 115 C100 C161.2 C153 C153.4C153.3C153.2C153.1 ST-C3.2 C147 C115 C113.1 C144 C148 C148.1 C148.2 C148.3 C153.5 ST-C1.1 C100.1 C1 5 9 . 2 OFFICE C 143 C143 FITNESS CENTER D 102 STAIR ST-C4 KING C.1 (C.F.) C 114 OFFICE C 144 KITCHEN C 154 SERVICE STATION C 157 W C 155 M C 156 BOARD ROOM C 158 HALLWAY C 160 V.I.P DINING 2 C 162 V.I.P DINING 1 C 163 JAPANESE RESTAURANT DINING C 164 MEETING ROOM C 159 C142 C145 C141 C113 C157 C152 C154 C163.1 C155 C156 WASHING C152.1 (E) OUTDOOR SHOWER ST-C1.1A C152.2 COOKING ST-C2.1 (E) DRINKING FOUNTAIN 73 ' - 0 " MF6-2 1 TYP 14' - 1" 3' - 7 1/8" D004 D123.1 XMA10-2 0 D123.2 C165.1 C146 C163 C162 C162.1 C159.1C159C158 JAPANESE RESTAURANT KITCHEN C 165 JAPANESE RESTAURANT V.I.P. SEATING C 166C166 C164.1 C166.1 SOBA PREP C 168 V.I.P. PREP C 167 (E) SHAFT ABOVE A3 1 A3 3 NOT IN SCOPE UNDER SEPARATE PERMIT 10.22 10.26 (E) TERRACE SERV C 169 NOT IN SCOPE LEGEND 1. ALL EXTERIOR DIMENSIONS ARE MEASURED TO GRID LINES & FACE OF SHEATHING ("EXTERIOR PLYWOOD SHEATHING" AT WOOD WALLS; "EXTERIOR BOARD SHEATHING" AT METAL WALLS. U.O.N 2. SEE A8 FOR INTERIOR PARTITION DETAILS. 3. ALL NEW STEEL COLUMNS AND BEAMS IN BLDG C SHOULD BE PROVIDED WITH 3HR SPRAY-ON FIREPROOFING. AND ENCLOSE COLUMNS IN THE WALL, U.N.O. 4. EVERY ASSEMBLY AREA SHALL HAVE THE OCCUPANT LOAD POSTED IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT OF THE ROOM. 5. ALL DOORS ARE PLACED 4" FROM ADJACENT WALL FINISH U.O.N. SHEET NOTES 6. PROVIDE ASSISTIVE LISTENING SYSTEMS IN ASSEMBLY AREAS PER CBC 11B-219. SEE G4.B 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 4 2 A M A2 BLDG. C FLOOR PLAN - LEVEL 1 (TI) HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SCALE: 3/32" = 1'-0" A21BLDG. C FLOOR PLAN - LEVEL 1 KEYNOTES 10.22 SURFACE MOUNTED FIRE EXTINGUISHER PER CBC. MIN 2A10BC AT BOH 10.26 FIRE EXTINGUISHER CABINETS PER CBC. MIN 2A10BC SEE 9/A8 AT RATED LOCATIONS N NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 UTILITYCABINET. UTILITYCABINET. 14 " x 4 8 " 1 4 " x 4 8 " 14"x36" 14"x36" 14"x36" J 12 13 11.5 12.5 B C D C.4 13.4 JAPANESE RESTAURANT DINING C 164 MB6-4 2 S1 2 S2 5 JAPANESE RESTAURANT KITCHEN C 165 CL 7' - 0 " 23 ' - 1 1 " CL 1' - 8 " 8' - 1 1/4" 1' - 8 3/4" 9' - 10" 13' - 3" MA6-2 0 MA6-2 0MA6-2 0 MA6-2 0 MB6-4 2 MR0-1 0 MA6-2 0 MA6-2 0 C166 JAPANESE RESTAURANT V.I.P. SEATING C 166 16 ' - 3 " C165.1SOBA PREP C 168 V.I.P. PREP C 167 C164 SHAFT ABOVE SERV C 169 32" TABLE WITH 27" HIGH, 30" WIDE, 19" DEEP CLEAR SPACE UNDER COUNTER (5% MIN. OF FIXED SEATING TO BE ACCESSIBLE) ACCESSIBLE COUNTER, 60" WIDE, 34" MAX HIGH WITH 27" HIGH, 30" WIDE, 19" DEEP CLEAR SPACE UNDER COUNTER MIN. 5' - 0" 5' - 0 " MA6-2 0 MA6-2 0 MA6-2 0 MA3-2 0 MR3-1 0 MR3-1 0 MR3-1 0 C164.1 C166.1 9' - 8"3' - 0" 4 1 / 2 " 3' - 0 " TRANSFORMER ABOVE, WALL MOUNTED, SEE ELECTRICAL DWG. FOR INSTRALLATION REQUIREMENTS WIC MA3-2 0 MA3-2 0 BAR WALL BELOW COUNTER, REFER TO ID DETAIL AND KITCHEN PLAN REQUIREMENT FOR LOCATION MA6-2 0 MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 2' - 1 1/8" 2' - 1 1/8" 7 3 / 8 " 1 0 3 / 8 " 1' - 2 " 8 1 / 4 " 2' - 1 1/8" 2' - 1 1/8" WOOD "SLAT" FABRICATED FROM MAPLE VENEERED FIRE-RETARDANT PARTICLE BOARD SEE ID 10.12, TYP 36 " M I N C L R 3' - 2 1 / 4 " 44 " M I N . C L R 3' - 8 1 / 2 " 4' - 1 1/4" 4' - 0 1/2" ELECTRICAL PANEL SEE ELECTRICAL DWG. (E) EXTERIOR STOREFRONT AND DOORS TO REMAIN, U.O.N 4"3' - 0" 3' - 1 3 / 4 " FIXED GLASS OVER THE COUNTER, S.I.D (E) EXTERIOR DOORS TO REMAIN, U.O.N (E) EXTERIOR DOORS TO REMAIN, U.O.N 7' - 0 " 1 ' - 3 " 3' - 9" 9.17 9.179.17 2' - 1 3/4"10 1/4" 7 5 / 8 " 7 5 / 8 " 10.27 10.27 10.27 10.28 MA6-2 0 (E) METAL STUD WALL WIC FABRICATED AND INSTALLED PER LARR 25747 MA3-2 0 12 1311.5 12.5 B C D C.4 13.4 JAPANESE RESTAURANT DINING C 164 JAPANESE RESTAURANT KITCHEN C 165 SOBA PREP C 168 JAPANESE RESTAURANT V.I.P. SEATING C 166 V.I.P. PREP C 167 9' -0" A.F.F. ACT2 (E) SHAFT ABOVE, PROVIDE 2HR 3M DUCT WRAP AT GREASE DUCT CONTINIOUS TO ROOF PER ICC ESR 1255 10' -0" A.F.F. GYP. BD. 3" x 6 " S l a t 10 ' - 6 " 9' -8" A.F.F. GYP. BD. 10' -0" A.F.F. GYP. BD. 8' -0" A.F.F. GYP. BD. 9' -0" A.F.F. GYP. BD. SERV C 169 7'-0" A.F.F. CASEWORK & SOFFIT ABOVE, SEE ID DWGS. 10'-0" A.F.F. WOOD SLATS ABOVE, SEE ID DWGS. HANGERS FROM CEILING ASSEMBLY, IF REQUIRED, ARE TO BE NON- COMBUSTIBLE. 9' -0" A.F.F. GYP. BD. KITCHEN HOOD KITCHEN HOOD OPENING FOR TRANSFORMER. (3) SIDES ARE CLOSED WITH GYP.BD HEADER PROVIDE NON-COMBUSTIBLE MATERIAL WITHIN 18" OF THE HOOD HOOD, SEE MECHANICAL. BOTTOM OF HOOD TO BE 18" BELOW CEILING AND 48" MAX ABOVE COOKTOP. PROVIDE NON-COMBUSTIBLE MATERIAL WITHIN 18" OF THE HOOD HOOD, SEE MECHANICAL. BOTTOM OF HOOD TO BE 18" BELOW CEILING AND 48" MAX ABOVE COOKTOP. EXP. CEILING TO FLOOR ABOVE EXP. CEILING TO FLOOR ABOVE WIC 1' - 0" 11 " 9' - 0 1/2" 11 " EQ EQ 5 ' - 3 " 5 ' - 3 " E Q 5' - 0 7/8" 4' - 7 1/4" 6' - 1 5/8" 6' - 11 5/8" 6' - 3 1/2" 6' - 7" CONTIOUS LIGHTING FIXTURE, SEE ID/LIGHTING/ELECTRICAL DWGS. CIRCULAR DIFFUSER, PAINTED TO MATCH CEILING COLOR. SEE MECH. DRAWINGS.CIRCULAR DIFFUSER, PAINTED TO MATCH CEILING COLOR. SEE MECH. DRAWINGS. 1' - 0 " 1' - 0" 1' - 0 " 1' - 0" EQ EQ EQ E Q E Q E Q E Q E Q EQ E Q E Q E Q 11"1' - 0" 1' - 0 " 2' - 0" 2' - 6 " 6 ' - 0 " 1' - 5 1/2" 1' - 5 1/2" EQ EQ 4' - 0 " 1 ' - 7 " 3' - 0" EQ EQ 4' - 10"4' - 10" 2' - 6 " EQ EQ EQ EQ 1' - 6 " 1' - 6 " 1' - 1 0 7 / 8 " 5 ' - 6 5 / 8 " 5 ' - 6 5 / 8 " 5 ' - 6 5 / 8 " 5 ' - 6 5 / 8 " 4 ' - 5 7 / 8 " 2 ' - 1 3 / 4 " 1' - 5 1/2" 1' - 5 1/2" 3' - 0 3/4" 3' - 8 3 / 8 " 1' - 1 0 7 / 8 " 6" EQ EQ AL I G N EQ EQ FIELD VERIFY. ALIGN WITH DOOR OPENING EQ EQ 12" WIDE GYP. CEILING POCKET 10' -0" A.F.F. GYP. BD. CLOSER PANEL TO TOP OF WIC CL EQ EQ CL EQ E Q 4' - 11" 9' -8" A.F.F. GYP. BD. GRILL, PLACE AS HIGH AS POSSIBLE, S.M.D SIDE WALL RETURN GRILL, PLACE AS HIGH AS POSSIBLE, S.M.D SIDE WALL RETURN GRILL, PLACE AS HIGH AS POSSIBLE, S.M.D WALL OPENING, S.I.D, TOP OF WALL 6'-8" MAX 4' - 5 3/8" EQ 4' - 8 5/8" EQ MUD IN DIFFUSER, S.M.D 6' - 0 " 2 ' - 6 " NOTE: SEE SHEET A1 FOR ACT CEILING TYPES. SEE TYPICAL DETAILS 4,7,8,12 ON SHEET A9. 10'-0" A.F.F. WOOD SLATS ABOVE, SEE ID DWGS. HANGERS FROM CEILING ASSEMBLY, IF REQUIRED, ARE TO BE NON-COMBUSTIBLE. 12 13 B 13.4 C159.2 HALLWAY C 160 BOARD ROOM C 158 MEETING ROOM C 159 6' - 11 1/4" 14' - 3 3/4" 8' - 1 1/4" 18 ' - 2 " 2' - 3 7 / 8 " 1' - 4 " MA4-2 0 MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 2' - 0"2' - 0" 8" 8 " 8" 8 " 1' - 4 " NOT IN SCOPE MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 MR3-1 0 12 13 B 13.4 HALLWAY C 160 MEETING ROOM C 159 BOARD ROOM C 158 8' -6" A.F.F. GYP. BD. EQ E Q 9' -0" A.F.F. GYP. BD. 2' - 0 " 6 ' - 3 " 3 ' - 2 5 / 8 " 6 ' - 3 " 2 ' - 0 " EQ EQ 3' - 0 " 2' - 0" 8' -0" A.F.F. GYP. BD. CEILING EDGE DETAIL PER ID PLAN LIGHTING PER ID/LIGHTING PLAN 9' -6" A.F.F. GYP. BD. 1' - 0" EQ E Q 10 ' - 0 " NOT IN SCOPE11 A9 TYP. 1. EXTERIOR WALL LOCATIONS, EXTERIOR STOREFRONT/WINDOW LOCATIONS AND SCHEDULE ARE UNDER SEPARATE PERMIT. EXISTING TO REMAIN, U.O.N 2. (E) STRUCTURAL ELEMENT & 3 HOUR SPRAY- ON FIREPROOFING TO REMAIN, U.O.N. 3. VERIFY ALL DIMENSIONS IN FIELD, TYP. 4. PREP. PRIME AND/OR REPAIR (E) WALL, CEILING, FLOOR SURFACE AS NECESSARY TO RECEIVE NEW FINISHES, V.I.F, TYP. 5. SEE G4.X SERIES FOR ACCESSIBILITY REQUIREMENTS. 6. SEE I.D AND ELECTRICAL DRAWINGS FOR RECEPTACLE LOCATIONS. 7. SEE I.D FOR FINISH SCHEDULE, ACCESSORY SCHEDULE, DRAPERY REQUIREMENTS 8. SEE ELECTRICAL DRAWINGS AND I.D. DRAWINGS FOR BLDG.C FLOOR OUTLET LOCATIONS. 9. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING & LIFE SAFETY DEVICES. 10. SEE MEP & FP DRAWINGS FOR MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION REQUIREMENTS. 11. SEE MECHANICAL DRAWINGS FOR HVAC SYSTEMS, EQUIPMENT, & THERMOSTAT LOCATIONS. 12. GC TO INSTALL CLEAR SEALANT WHERE DISSIMILAR MATERIALS MEET. 13. PROVIDE BLOCKING FOR ACCESSORIES INCLUDING (BUT NOT LIMITED TO) GRAB BARS, SHELF AND FOOTREST, FIXED GLASS SHOWER PANEL, TOWEL RACKS, SHOWER CURTAIN ROD ETC. 14. PROVIDE BLOCKING FOR ELECTRICAL ITEMS INCLUDING WALL OUTLETS IF A SPECIFIC LOCATION HAS BEEN IDENTIFIED. PATCH AND REPAIR (E)ADJ WALL AS REQ'D 15. PROVIDE BACKING AT ALL TVS AS REQUIRED. 16. FIRE SPRINKLER SYSTEM DEFERRED SUBMITTAL. 17. FURNITURE AND BAR EQUIPEMENT SHOWN FOR REFERENCE ONLY. 18. GC TO COORDINATE ALL CEILING FIXTURES, DEVICES, DETECTORS OR ANY ELEMENTS SUCH AS SPRINKLER HEADS IN FIELD. APPROVAL FROM AOR IS REQUIRED. 19. ELECTRICAL DEVICES SHOWN ON POWER PLAN ARE FOR SERVING FFE AND BRAND. REFER TO I.D. DRAWINGS FOR ADDITIONAL INFORMATION AND TO COORDINATE DEVICE LOCATIONS WITH FFE. SEE FULL ELECTRICAL REQUIREMENT IN ELECTRICAL PLANS FOR THE DEVICES NOT SHOWN. 20. HVAC AND ACCESS PANEL LOCATIONS PER MECHANICAL DRAWINGS. COORDINATE ACCESS PANEL AS REQUIRED WITH ALL CEILING ELEMENTS. APPROVAL FROM AOR IS REQUIRED. 21. ALL OWNER SUPPLY EQUIPEMENTS MUST BE VERIFIED FOR REQ'D SPACE, CONNECTIONS, SUPPORT WITH ALL NECESSARY REQUIREMENTS TO INSTALL PRIOR TO ORDER AND TO BE RECEIVED BY THE CONTRACTOR, TYP. 22. WALL, FLOOR AND CEILING SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.11. 23. ROOMS AND ENCLOSED SPACES MIN FLAME SPREAD C (COMPLIANCE WITH 803.1 AND TABLE 803.13) 24. EVERY ASSEMBLY AREA SHALL HAVE THE OCCUPANT LOAD POSTED IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT OF THE ROOM. SEE G4.B FOR SIGNAGE REQUIREMENTS. 25. THE (E) WINDOWS ARE FIXED, AND THE (E) EXTERIOR DOORS ARE SELF-CLOSING AND RODENT PROOFED SHEET NOTES (TI) NOT IN SCOPE LEGEND 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 4 5 A M A3 BLDG.C ENL. PLAN - JAPANESE RESTAURANT (TI) HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT N KEYNOTES 9.17 PROVIDE STAINLESS STEEL AT BACK WALL, SEE KITCHEN DRAWINGS (MUST MEET CMC 507.4.2.3 ZERO CLEARANCE AT TYPE I HOOD) 10.27 TACTILE EXIT SIGN, 48" MIN TO BOTTOM OF LOWEST BRAILLE, REFER TO 10/G4.B 10.28 OCCUPANT LOAD SIGN SCALE: 1/4" = 1'-0" A31ENL. JAPANESE RESTAURANT - LEVEL 1 (TI) SCALE: 1/4" = 1'-0" A32ENL. JAPANESE RESTAURANT RCP - LEVEL 1 (TI) SCALE: 1/4" = 1'-0" A33ENL. WALKWAY - LEVEL 1 (TI) SCALE: 1/4" = 1'-0" A34ENL. WALKWAY RCP - LEVEL 1 (TI) NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 1. ALL EXTERIOR DIMENSIONS ARE MEASURED TO GRID LINES & FACE OF SHEATHING, U.O.N. 2. SEE WINDOW SCHEDULE A0.21 FOR ALL WINDOW & EXTERIOR LOUVER SIZES. 3. ALL WINDOWS ARE LOCATED ON FLOOR PLANS A2.00 SERIES. 4. SEE ELEVATIONS ON A4.00 SERIES FOR ALL EXTERIOR FINISH MATERIALS. 5. ALL SIGNAGE REQUIRES SEPARATE PERMIT BY SIGN CONTRACTOR. 6. SEE A9.01 FOR EXTERIOR PARTITION DETAILS. 7. SEE A9.20 SERIES FOR EXTERIOR WINDOW DETAILS. 8. SEE G0.3X SERIES FOR ACCESSIBILITY REQUIREMENTS. 9. SEE ELECTRICAL DRAWINGS FOR RECEPTACLE LOCATIONS. 10. SEE A2.0X AND A2.1X SERIES FOR OVERALL WALL DIMENSIONS 11. SEE I.D FOR FINISH SCHEDULE AND ACCESSORY SCHEDULE. 12. DRAPERY TO BE MANUAL IN TYP. GUESTROOMS AND SINGLE HEIGHT PUBLIC SPACES. DOUBLE HEIGHT PUBLIC SPACE DRAPERY TO BE MOTORIZED. BALLROOM/ MEETING ROOM DRAPERY TO BE MOTORIZED. REFER TO ID DRAWINGS. 13. SEE ELECTRICAL DRAWINGS AND I.D. DRAWINGS FOR BLDG.C FLOOR OUTLET LOCATIONS SHEET NOTES 10 11 B W C 155 M C 156 C155 C156 C155.1 C156.3 C156.2 C156.1 C155.5C155.4C155.3C155.2 MA6-2 0 MR3-1 0 MA3-2 0 MA6-2 0 MR3-1 0 MR3-1 0 MA6-2 0 MR3-1 0 MA3-2 0 MA6-2 0 MA3-2 0 MA3-2 0 MA3-2 0 MR3-1 0 4' - 8 " M I N . 4' - 8 " M I N . 4" 4" 5' - 5 1/2" 1' - 7 " 2' - 3"2' - 3" 3' - 4 " 3' - 4 " 13' - 11 1/2" 1' - 8 1/2" 4' - 10 3/4" 12' - 3 7/8" 2' - 2" 11 1/8" CL 4' - 9" 1' - 7 1 / 2 " 7 ' - 2 3 / 8 " 8 ' - 1 0 7 / 8 " 5 ' - 8 5 / 8 " 8" 3 ' - 3 1 / 2 " 6' - 0 3/4" 6' - 4 1/2" 10 3/4" MA3-2 0 MR3-1 0 MR3-1 0 MR3-1 0 5' - 6 " 1 ' - 6 1 / 4 " 6' - 0 1 / 4 " CL 4' - 0" 13' - 7 7/8" CLCLCL EQ EQ TYP. 3' - 2 1/4" 6' - 0 3/4" AREA OF 44" MIN. CLEAR ACCESSIBLE PATH OF TRAVEL, IN GREY TYP. AT STALLS MA3-2 0 MA3-2 0 BABY CHANGING STATION AT 34" AFF MAX, SEE ID BABY CHANGING STATION, SEE I.D 1' - 7 " BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' 10 11 B W C 155 M C 156 9' -0" A.F.F. GYP. BD. 9' -0" A.F.F. GYP. BD. 1' - 4" 1' - 4 " 1' - 4" 3' - 4 " 1' - 4" 1' - 4 " 1' - 4"1' - 4 " 1' - 4" 1' - 8 " 1' - 8 " 1' - 4"1' - 4" 9' -6" A.F.F. GYP. BD.9' -6" A.F.F. GYP. BD. 9' -6" A.F.F. GYP. BD. 9' -6" A.F.F. GYP. BD. 9' -6" A.F.F. GYP. BD. D1 D2 DC.5 DE.5 DD.5 A3.1216 13 15 14 D122 D121 5'- 0 " M I N . C L R . 5' - 2 1 / 2 " 5'- 0 " M I N . C L R . 5' - 2 1 / 2 " W D 122 M D 121 9' - 6 1 / 2 " 5 1/8" 8' - 9 1/2" 1' - 0" 2' - 5 7 / 8 " 8 ' - 7 1 / 2 " XMA10-2 0 XMA10-2 0 MA6-2 0 MR3-1 0 MR3-1 0 XMA10-2 0 XMA6-2 0 MR3-1 0 MR3-1 0 MR0-1 0 XC12 0 5/8"1' - 1" POOL SHOWER A3.12 17 18 5' - 6 3 / 4 " 4 7/8"3' - 2 1/8" 18 " M I N 1' - 6 1 / 2 " CLR 4'-0" MIN CLR 5'-0" MIN D1 D2 DE.5 DD.5 8' -0" A.F.F. GYP. BD. 8' -0" A.F.F. GYP. BD. BLDG. C & D LEVEL 1 EL +0.00' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG. C & D LEVEL 1 EL +0.00' BLDG. D LEVEL 2 EL +10.00' SEE G0.37 FOR R.I.S REQUIREMENTS TILE SURROUND BLDG. C & D LEVEL 1 EL +0.00' BLDG. D LEVEL 2 EL +10.00' SEE G0.37 FOR R.I.S REQUIREMENTS TILE SURROUND 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 6/ 9 / 2 0 2 5 1 1 : 0 4 : 3 0 A M A3.12 ENL. PLAN -PUBLIC RESTROOM HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. N KEYNOTES SCALE: 1/4" = 1'-0"A3 . 1 21ENL. PUBLIC RESTROOM - 1 SCALE: 1/4" = 1'-0"A3 . 1 25PUBLIC RESTROOM ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 26PUBLIC RESTROOM ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 28PUBLIC RESTROOM ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 27PUBLIC RESTROOM ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 22ENL. PUBLIC RESTROOM RCP - 1 1. PROVIDE BLOCKING, OR DIRECT STUD SUPPORT, FOR ALL TOILET ACCESSORIES 2. APPROVED METAL FINISHES: POLISHED OR BRUSHED CHROME, BRUSHED NICKEL OR STAINLESS STEEL 3. WALL MOUNTED ACCESSORIES, FIXTURES ETC. BETWEEN 27" AND 80" A.F.F. SHALL NOT PROTRUDE FURTHER THAN 4" FROM WALL PER ACCESSIBILITY STANDARDS. CONSULT THE 2003 ICC/ANSI A117.1 FOR FURTHER REQUIREMENTS. 4. ALL CONTROLS FOR USE BY GUESTS MUST BE MOUNTED AT BETWEEN 15" A.F.F. AND 48" A.F.F. AND PROVIDE A 30"X48" CLEAR FLOOR AREA IN COMPLIANCE WITH ACCESSIBLE STANDARDS. OPERABLE CONTROLS LOCATED OVER AN OBSTRUCTION DEEPER THAN 10" MUST BE MOUNTED NO HIGHER THAN 46" A.F.F.. ACCESSIBLE CONTROLS MUST NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. ACCESSIBLE CONTROLS SHALL COMPLY WITH THE 2003 ICC/ANSI A117.1 5. ALL SINGLE ACCOMMODATION RESTROOMS MUST BE IDENTIFIED AS ALL-GENDER TOILET FACILITIES. PER DSA POLICY, THE UNISEX RESTROOM SYMBOL COMPLIES WITH THIS REQUIREMENT. SEE A.B.1732 IN 2016 AND H & S CODE 118600 AND CPC 422.2.1. 6. IN OTHER THAN DWELLING UNITS, TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE SUCH AS PORTLAND CEMENT, CONCRETE, CERAMIC TILE OR OTHER APPROVED MATERIAL WHICH EXTEND UPWARD ONTO THE WALLS AT LEAST 4 INCHES. WALLS WITHIN 24 INCHES OF THE SERVICE SINKS, WATER CLOSETS AND URINALS SHALL BE SIMILARLY FINISHED TO A HEIGHT OF 48 INCHES AND, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE TYPE WHICH IS NOT ADVERSELY AFFECTED BY MOISTURE. (CBC 1210.2.2). SEE ID DRAWINGS FOR FINISH SCHEDULE. SCALE: 1/4" = 1'-0"A3 . 1 23ENL. RESTROOM PLANS - LEVEL 1 SCALE: 1/4" = 1'-0"A3 . 1 24ENL. RESTROOM RCP - LEVEL 1 SCALE: 1/4" = 1'-0"A3 . 1 214STANDARD STALL ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 215STANDARD STALL ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 213STANDARD STALL ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 216STANDARD STALL ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 29PUBLIC RESTROOM ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 210PUBLIC RESTROOM ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 211PUBLIC RESTROOM ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 212PUBLIC RESTROOM ELEVATION SCALE: 1/4" = 1'-0"A3 . 1 218POOL SHOWER - NORTH SCALE: 1/4" = 1'-0"A3 . 1 217POOL SHOWER - EAST *NOTE: SOUTH SHOWER ELEVATION SIMILAR NO.DATE ISSUES & REVISIONS 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) 06.09.25 BULLETIN 14 All single accommodation restrooms must be identified as all-gender toilet facilities. Per DSA Policy, the unisex restroom symbol complies with this requirement. See A.B.1732 in 2016 and H & S Code 118600 and CPC 422.2.1. 06/17/2025 CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________EP 06/18/2025 25-1247 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' BLDG. C UPPER ROOF (T.O.S) EL +48.83' 137.5 8.5 9.5 10.5 11.5 12.5 13.4 13.5 BLDG.C (E) BASEMENT EL -12.00' AVERAGE GRADE EL -0.60' D2 D3.1 2 A5.04 60 ' - 1 0 " STAIR ST-C2 STAIR ST-C2 STAIR ST-C2 BAR LOUNGE ELEVATOR LOBBY RESTAURANT DINING (THE OVALO) C 161 V.I.P DINING 1 C 163 JAPANESE RESTAURANT DINING C 164 IDF C 246 IDF C 346 BLDG.C PLANNING HEIGHT LIMIT EL +49.73' MA X A L L O W A B L E H E I G H T P E R Z O N I N G 50 ' - 4 " BLDG. C (E) ROOF H.P. (T.O.C) EL +38.83' 10 ' - 0 " 1 3 ' - 6 " 1 2 ' - 5 " 1 2 ' - 1 1 " 1 2 ' - 0 " BLDG. C ROOFTOP PATIO EL +39.33' 6 A8.06 1 A8.06 TYP. (E) 4" SLAB ON GRADE, S.S.D. (E) 4" SLAB ON GRADE, S.S.D. NO FIRE RATING REQUIRED @ STAIR ROOF WHERE EXTENDED ABOVE MAIN ROOF SHEATHING PER CBC 713.12 BLDG. C & D LEVEL 1 EL +0.00' BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' BLDG. C UPPER ROOF (T.O.S) EL +48.83' 10.6 2 3 4 5 60.5 2.5 3.5 4.5 5.5 6.5 BLDG.C (E) BASEMENT EL -12.00' AVERAGE GRADE EL -0.60' 1.5 2 A5.02 STAIR ST-C1 STAIR ST-C1 STAIR ST-C1 EXECUTIVE LOUNGE C 147 BAR LOUNGE C 150 BAR LOUNGE C 150 ENGINEERING OFFICE B02 QQ C.1 C 112 KING C.1 C 110 KING C.1 C 108 QQ C.1 C 106 KING C.1 C 104 QQ C.3 C 102 ELEC. C 243 IDF C 343 OPEN TO BELOW BAR/ DINING MA X A L L O W A B L E H E I G H T P E R Z O N I N G 50 ' - 4 " BLDG.C PLANNING HEIGHT LIMIT EL +49.73' BLDG. C (E) ROOF H.P. (T.O.C) EL +38.83' 10 ' - 0 " 1 3 ' - 6 " 1 2 ' - 5 " 1 2 ' - 1 1 " 1 2 ' - 0 " 6 A8.06 BLDG. C ROOFTOP PATIO EL +39.33' PANTRY C 403 DINING C 401 BAR C 402 W C 404 M C 405 DINING C 401.1 6 A8.06 2HR RATED FLOOR, S.S.D. SEE SHEET A8.06 FOR FLOOR ASSEMBLIES. SEE SLAB PLAN FOR AREAS OF INFILL. 1 A8.06 TYP.3 A8.06 6 A8.06 6 A8.06 NO FIRE RATING REQUIRED @ PROJECTION PER CBC 705.2 PROJECTION NO FIRE RATING REQUIRED @ STAIR ROOF WHERE EXTENDED ABOVE MAIN ROOF SHEATHING PER CBC 713.12 1. SEE WINDOW SCHEDULE A0.21 FOR ALL WINDOW SIZES. 2. SEE LOUVER SCHEDULE A0.21 FOR ALL EXTERIOR LOUVER SIZES. 3. ALL WINDOWS ARE LOCATED ON FLOOR PLANS A2.00 SERIES. 4. SEE ELEVATIONS ON A4.00 SERIES FOR ALL EXTERIOR FINISH MATERIALS. 5. ALL SIGNAGE REQUIRES SEPARATE PERMIT BY SIGN CONTRACTOR 6. SEE A9.01 FOR EXTERIOR PARTITION DETAILS. 7. SEE A9.20 SERIES FOR EXTERIOR WINDOW DETAILS. 8. COLORS SHOWN ARE DIAGRAMMATIC; R EFER TO THE COLORS/MATERIALS REFERENCED ON THE FINISH LEGEND/SCHEDULE AND/OR PHYSICAL SAMPLES FOR AN ACCURATE DEPICTION OF INTENDED COLOR SHEET NOTES 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 12 / 2 4 / 2 0 2 4 1 0 : 3 2 : 3 0 A M A5.01 BLDG. C SECTIONS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. SCALE: 1/8" = 1'-0"A5 . 0 12BLDG. C SECTIONS A SCALE: 1/8" = 1'-0"A5 . 0 11BLDG. C SECTIONS B KEYNOTES NO.DATE ISSUES & REVISIONS 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) 12.16.24 BULLETIN 10 01/20/2025 CITY OF ARCADIA DEVELOPMENT SERVICES DIVISION APPROVED By Subject to field inspection approval. The stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance, State Law or Recognized Standard __________________________EP 01/21/2025 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T MAX HEIGHT STUDS @ 16" O.C. MAX HEIGHT STUDS @ 24" O.C. W/ GYP. BD. EACH SIDE W/ GYP. BD. ONE SIDE ONLY W/ GYP. BD. EACH SIDE W/ GYP. BD. ONE SIDE ONLY STUD GAUGE STUD SIZE 1 5/8" 25 6'-11" 10'-1" 5'-2" 8'-9" 22 8'-2" 10'-7" 6'-3" 9'-1" 20 8'-8" 10'-9" 6'-7" 9'-4" 22 11'-3" 13'-11" 10'-6" 10'-11" 20 12'-0" 14'-3" 11'-6" 12'-5" 22 15'-0" 16'-6" 14'-1" 14'-5" 20 16'-0" 17'-5" 15'-1" 15'-3" 2 1/2" 3 5/8" 4" 6" 22 20 22 20 16'-2" 17'-8" 15'-0" 15'-5" 21'-6" 24'-4" 17'-7" 21'-3" 17'-3" 18'-3" 16'-3" 15'-11" 23'-9" 25'-6" 20'-6" 22'-3" SUBCONTRACTOR TO ENGINEER AND DETAIL LIGHT GAUGE METAL FRAMING PER MANUFACTURER'S SPAN TABLES AND CONTRACT DOCUMENT SPECIFICATION REQUIREMENTS. DATA DERIVED FROM SSMA TECHNICAL GUIDE INTERIOR APPLICATION OF HEAVY DUTY "C" STUDS WITH DEFLECTION OF L/240. THE ABOVE SIZES ARE MINIMUM, USE HEAVIER GA. AS REQUIRED.SEE STUCTURAL FOR SPAN TABLE3 1/2" MIN GLASS FIBER INSULATION FRICTION FIT BETWEEN STUDS. UNDERSIDE OF STRUCTURE CEILING WHERE OCCURS 5/8" TYPE 'X' GYP. BD. BOTH SIDES, SEE BELOW FOR NUMBER OF LAYERS BASE AS SCHEDULED ACOUSTICAL SEALANT MTL. STUDS, SEE STRUCTUAL FOR GAUGE HEAD PLAN SILL MA3-2 3-5/8" MTL STUD MA6-2 6" MTL STUD MA3-3 3-5/8" MTL STUD MA6-3 6" MTL STUD MA3-4 3-5/8" MTL STUD MA6-4 6" MTL STUD (2) LAYERS GYP. BD. ON ONE SIDE AND (1) LAYER GYP. BD. ON ONE SIDE. (2) LAYERS GYP. BD. ON BOTH SIDES (1) LAYER GYP. BD. ON BOTH SIDES STC 50-54 (GA FILE NO. WP 1048) STC 50-54 (GA FILE NO. WP 1052) STC 50-54 (GA FILE NO. WP 1450) UNDERSIDE OF STRUCTURE CEILING WHERE OCCURS ACOUSTICAL/FIRE SEALANT MTL. STUDS, SEE STRUCTUAL FOR GAUGE BASE AS SCHEDULED 5/8" TYPE "X" GYP. BD., SEE BELOW FOR NUMBER OF LAYERS HEAD PLAN SILL GLASS FIBER INSULATION FRICTION FIT BETWEEN STUDS. MR3-1 3 5/8'' STUD MR6-1 6'' STUD MR3-2 3 5/8'' STUD MR6-2 6'' STUD MR0-1 *** SEE DETAIL MR0 (2) LAYERS TYPE 'X' GYP. BD. (1) LAYER TYPE 'X' GYP. BD. ACOUSTICAL/FIRE SEALANT CONC. WALL, SEE STRUCT. UNDERSIDE OF STRUCTURE CEILING WHERE OCCURS 5/8" GYP. BD. ON ONE SIDE BASE AS SCHEDULED 7/8" FURRING CHANNEL @ 24" O.C. SEE STRUCTUAL HEAD PLAN SILL ACOUSTICAL SEALANT -6" MR0-1 BASE AS SCHEDULED 5/8" GYSUM BOARD CL 6" 6'- 0 " M A X . UNDERSIDE OF STRUCTURE STEEL STUD KICKERS,SEE STRUCTUAL DEFLECTION TRACK BRACING, SEE STRUCT. DWGS. METAL STUDS, SEE STRUCTUAL 1 1 1 1 SEE STRUCTUAL A B SEE STRUCTUAL. UNDERSIDE OF STRUCTURE SLIP TRACK (2" LEG MINIMUM) ACOUSTICAL SEALANT ACOUSTICAL SEALANT 1/4" THICK X 1-1/2" WIDE CONTINUOUS COMPRESSION TAPE HEAD SILL SEE STRUCTUAL FLOOR SLAB 1/ 2 " WALL TYPE SEE FLOOR PLAN FOR POSITION 1 ('M'): STUD MATERIAL, METAL (M) OR WOOD (W) POSITION 2 ('A'): TYPE OF WALL (SEE BELOW) POSITION 3 ('6'): STUD SIZE (SEE BELOW) POSITION 4 ('4'): LAYERS OF GYP. BD. (SEE BELOW) PARTITION TYPE: SEE 'PARTITION TYPE NAMING CONVENTION' ON Axx A MA6-4 0 FIRE RATING (HRS) MODIFIER: SEE PARTITION COMPONENT MATRIX ON Axx PARTITION TYPE LEGEND NO 3 1/2" GLASS FIBER INSULATION STOP GYP BD. 6" ABOVE CEILING, SEE DETAIL ADD 1 LAYER OF TILE BACKER (SEE DETAIL 1&5/A8.72) SUBSTITUTE FIBERGLASS-MAT FACED, MOISTURE AND MOLD RESISTANT GYP. SHEATHING NO GYP BD. ON INTERIOR SIDE A B C D E F G H i J K L NO RESILIENT CHANNEL M N SUBSTITUTE WATER RESISTANT GYP. BD. ADD EXTRA LAYER OF GYP. BD. ON EACH SIDE PARTIAL HEIGHT WALL WALL ON TOP OF 4FT CMU WALL, SEE DETAIL GYP. BOARD, PROVIDE TYPE 'X' WHERE REQ'D METAL STUD RECESSED PANEL ENCLOSURE ACOUSTICAL SEALANT AT ALL PENETRATIONS NOTES: 1. LINE TOP, BOTTOM, BACK AND SIDES WITH (1) LAYER 5/8'' GYP. BD. OR 2 PSF. SHEET VINYL 2. SEE PLANS TO VERIFY NUMBER OF GYP. BD. LAYERS 1'' CLEARANCE REQUIRED; FILL WITH BATT INSULATION PER PLAN WALL TYPE 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 4 7 A M A8 WALL TYPES AND INTERIOR DETAILS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT STEEL STUD GAUGE AND HEIGHT SCALE: 1 1/2" = 1'-0" A8MASINGLE STUD, NON-RATED SCALE: 1 1/2" = 1'-0" A8MRINT. FURRING WALL, NON-RATED SCALE: 1 1/2" = 1'-0" A8MR0MR0-1, FURRING WALL SCALE: 1 1/2" = 1'-0" A84WALL STOPPING JUST ABOVE CEILING SCALE: 3" = 1'-0" A85HEAD/SILL DETAIL - NON-RATED WALL SCALE: 3" = 1'-0" A86GYP.JOINT DETAIL PARTITION MATRIX MODIFIER SCALE: 1 1/2" = 1'-0" A89RATD RECESSED PANELS AND FIXTURES NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 3B 3A 1 2 A -A 1. WALL ASSEMBLY -1 HR GYP. BD. WALL ASSEMBLY 2. THROUGH PENETRANT: A. STL. PIPE -4" ∅OR SMALLER B. IRON PIPE -4" ∅OR SMALLER C. CONDUIT -4" ∅OR SMALLER D. COPPER PIPE OR TUBE -4" ∅OR SMALLER 3. FIRESTOP SYSTEM A. PACKING MATERIAL: MIN. 1" FO MIN. 3.5 PCF FIBERGLASS INSULATION B. CAULK OR PUTTY: MIN. 5/8" THICK SPECSEAL 100 SEALANT AND SPECSEAL PUTTY A A 2 3A 3B 1. GYPSUM WALL ASSEMBLY (UL/ULC CLASSIFIED U300 OR U400 SERIES) (2-HR FIRE-RATING). 2. #8 STEEL WIRE MESH SLEEVE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAX. 16" NOMINAL Ø STEEL PIPE. B. MAX. 4" NOMINAL Ø COPPER PIPE. 4. MIN. 4-1/2" THICKNESS MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED. 5. MIN. 1/4" DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 6. MIN. 1/2" BEAD HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES: 1. Ø OF OPENING SHALL BE 3/8" TO 2-3/4" LARGER THAN THE Ø OF THE PIPE. 2. WHEN STEEL PIPE IS USED, ANNULAR SPACE = 0" TO 2-3/4", AND THE T-RATING = 1/4 HR. 3. WHEN COPPER PIPE IS USED, ANNULAR SPACE = 0" TO 3", AND THE T-RATING = 0 HR. 4. MAX. Ø OF OPENING IS 14-1/2" FOR WOOD STUD WALLS AND 20" STEEL STUD WALLS. A B UL/cUL SYSTEM NO. WL1058 METAL PIPE THROGUH A SLEEV IN 2-HR. GYPSUM WALL ASSEMBLY F RATING = 2-HR. T RATING = 0 AND 1/4 - HR. FRONT VIEW SECTION A-A 2 45 1 3 6 +/ - 1 / 2 ' ' SUPPORT (AS NEEDED) BOTH SIDES 4'' - 8'' TYP. ACOUSTICAL SEALANT (TYP.) FOAM BACKER ROD SAFING BATT INSULATION (DUCT, PIPE, OR CONDUIT 3'' DIAMETER OR GREATER) NOTE: APPLICABLE AT ALL SOUND-RATED CONSTRUCTION INCLUDING INTERIOR INSULATED ASSEMBLIES 1'' M I N . KEEP PIPE CLEAR OF STRUCTURE EXCEPT AT HEAD AND SILL PLATESVENT PIPE1/ 2 ' ' M I N . C L E A R A N C E SUPPLY PIPE ADJUST DEPTH OF PARTITION TO ACCOMMODATE DRAIN LINE BATT INSULATION GYP. BOARD 1/ 2 ' ' M I N . C L E A R A N C E 1'' M I N . C L E A R A N C E . 3 4 2 53 1. PLYWD. SHTG. PER STRUCT. 2. THROUGH PENETRANT: A. STL. PIPE - 4" ∅OR SMALLER B. IRON PIPE - 4" ∅OR SMALLER C. CONDUIT - 4" ∅OR SMALLER D. COPPER PIPE OR TUBE - 4" ∅OR SMALLER 3. FIRESTOP SEALANT: SPECSEAL LCI SEALANT 5/8" INTO CLNG. AND 3/4" INTO FLR. 4. WD., STL., OR COMBINATION WD./STL. JOISTS OR TRUSSES 5. GYP. BD. CLNG. 1/2'' +/- 1/4'' CAULK AIRTIGHT; USE FIRE-RATED RESILIENT FILLER IF REQUIRED FOR FIRE RATING STEEL PLATE (OPTIONAL) 3/4'' NEOPRENE WAFFLE PAD (40-DUROMETER) FLOOR CONSTRUCTION SAFING BATT INSULATION IF REQUIRED FOR FIRE RATING NOTE: IF PIPE IS SUSPENDED FROM-OR DIRECTLY ATTACHED TO STRUCTURE OR OTHER BUILDING ELEMENTS, USE 3/8'' THICK FELT, OR 40-DUROMETER NEOPRENE AS SLEEVE BETWEEN PIPE AND PIPE HANGER FLOOR DO NOT ALLOW CHUTE TO CONTACT FLOOR STRUCTURE SUPPORT WITH KINETICS AC-222 FIBERGLASS ISOLATORS, MASON BR NEOPRENE MOUNTS, OR APPROVED EQUAL CAULK JOINTS AIRTIGHT, TYP. USE RETARDER WITH HOPPER DOOR TO PREVENT DOOR IMPACTS TWO LAYERS GYP. BOARD EACH SIDE BATT INSULATION COAT WITH SOUNDCOAT GP-1 OR KINETICS KDC- E-162 ONE TIMES METAL THICKNESS CL P A R T I T I O N RA T E D RATED PARTITION -SEE WALL TYPE ON FLOOR PLAN FIRE/SMOKE DAMPER (SEE MECH.) FIRE RATED SEALANT DUCT METALLIC PIPE LCI SEALANT LCI SEALANT WOOD FLOOR ASSEMBLY INSULATED METALLIC PIPE LCI SEALANT LCI SEALANT WOOD FLOOR ASSEMBLY UL SYSTEM NO.: F-C-1074 UL SYSTEM NO.: F-C-5043 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 4 9 A M A8.a FLOOR/WALL PENETRATION DETAILS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SCALE: 3" = 1'-0"A8 . a1TYPICAL RATED WALL PENETRATION SCALE: 3" = 1'-0"A8 . a2HILTI FIRE STOP - PIPE PENETRATION SCALE: 3" = 1'-0"A8 . a3SOUND RATED PENETRATION SCALE: 3" = 1'-0"A8 . a4PIPING WALL WIDTH & CLEARANCES SCALE: 3" = 1'-0"A8 . a5TYPICAL RATED FLOOR PENETRATION SCALE: 3" = 1'-0"A8 . a6PIPE RISER ISOLATION SCALE: 1" = 1'-0"A8 . a7ACOUS. TREATMENT OF LINEN CHUTE SCALE: 3" = 1'-0"A8 . a8RATED WALL PENETRATION SCALE: 1 1/2" = 1'-0"A8 . a9METALLIC PIPE PENETRATION NO.DATE ISSUES & REVISIONS 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 5 0 A M A8.b FLOOR/WALL PENETRATION DETAILS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 5 2 A M A8.c FLOOR/WALL PENETRATION DETAILS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 DB MQ6-2 2 WB8-4 2 WB8-4 2 CORRIDOR D 300 ELEC. D 307 SHAFT ELEV. SHAFT WD6-2 1 CORNER REINFORCEMENT GYPSUM PANELS STEEL J-RUNNERS 1" GYP. BD. SHAFT WALL LINER NOTE: REFER TO 5/A8.34 FOR TYP GYPSUM DESIGN DETAILS 7' - 5 1/4"1' - 8 3 / 8 " STEEL J-RUNNERS FIRE SEALANT FIRE SEALANT WOOD STUD, S.S.D WOOD STUD, S.S.D WOOD STUD, S.S.D WOOD STUD, S.S.D WB8-4 2 WD6-2 1 WB8-4 2 GYP BD TO BOX OUT AROUND GUIDE RAIL SUPPORT COLUMNS TO MAINTAIN WALL RATING GYP BD TO BOX OUT AROUND GUIDE RAIL SUPPORT COLUMNS TO MAINTAIN WALL RATING WB8-4 2 B C 13.45 A8.35 3 A8.35 MB6-4 2 MQ6-2 2 MQ6-2 2 MR6-1 0 XMA6-2 0 STAIR ST-C2 CORRIDOR C 200 KING C.3 C 241 6' - 5 " 4' - 0" 4' - 0 1/2" SEE MECH. DWGS FOR DUCT SIZES (E) COLUMN/BEAM WITH 3HR SPRAY- ON FIRE PROOFING. (E) COLUMN/BEAM WITH 3HR SPRAY- ON FIRE PROOFING. STEEL J-RUNNERS FIRE SEALANT STEEL J-RUNNERS MR0-1 0 MR3-1 0 NOTE: REFER TO 5/A8.34 FOR TYP GYPSUM DESIGN DETAILS FIRE SEALANT AT END CONDITIONS, TYP. STEEL J-RUNNERS XMB10-2 1 2 1 / 2 " MB6-4 2 MR6-1 0 MQ6-2 2 STEEL J-RUNNERS FIRE SEALANT AT END CONDITIONS, TYP. 1" GYP. BD. SHAFT WALL LINER MR3-1 0 SHAFT EXTERIOR 14"X14" 2-HR RATED ACCESS PANEL (FOR CLEANOUT ONLY). CONFIRM GREASE DUCT EXACT LOCATION WITH MECH CONTRACTOR 13.4 CORRIDOR C 300 CORRIDOR C 200 EXTERIOR (E) COLUMN/BEAM WITH 3HR SPRAY-ON FIRE PROOFING. (E) COLUMN/BEAM WITH 3HR SPRAY-ON FIRE PROOFING. STEEL PLATE, S.S.D (N) BEAM, S.S.D. WITH 3HR SPRAY-ON FIRE PROOFING. (N) BEAM, S.S.D. WITH 3HR SPRAY-ON FIRE PROOFING. NOTE: REFER TO 5/A8.34 FOR TYP GYPSUM DESIGN DETAILS A8.35 4 TYP. A8.35 4 TYP. A8.35 4 TYP. A8.35 4 TYP. PER PLAN WALL TYPE (E) SLAB, S.S.D (E) SLAB, S.S.D 1" GYP. BD. SHAFT WALL LINER FIRE SEALANT AT END CONDITIONS, TYP. FIRE SEALANT AT END CONDITIONS, TYP. STEEL J-RUNNERS SHAFT STEEL PLATE, S.S.D FO R D U C T S I Z E S SE E M E C H D W G S . 3M 2HR DUCT WRAP, TYP. 2 HOUR FIRE BARRIER AT CLEANOUT WHERE OCCURS PER ICC REPORT ESR-1255 90 MINS ACCESS DOOR 1 ADDITIONAL LAYER OF TYPE 'X' GYP. BD. CEILING HEIGHT PER PLAN 1" GYP. BD. SHAFT WALL LINER 1" GYP. BD. SHAFT WALL LINER FIRE SEALANT AT END CONDITIONS, TYP. FIRE SEALANT AS NEEDED FIRE SEALANT AS NEEDED SEAL THE GAP WITH FIRE SEALANT PER ICC ESR 1255 BLDG. C (E) LEVEL 2 EL +12.92' BLDG.C (E) LEVEL 3 EL +25.33' B C STAIR ST-C2 (E) COLUMN/BEAM WITH 3HR SPRAY-ON FIRE PROOFING. (E) COLUMN/BEAM WITH 3HR SPRAY-ON FIRE PROOFING. 7/8" FURRING CHANNEL @ 24" O.C. 1 ADDITIONAL LAYER OF TYPE 'X' GYP. BD. CEILING HEIGHT PER PLAN WALL PARTITION, SEE PLAN WHERE OCCURS NOTE: REFER TO 5/A8.34 FOR TYP GYPSUM DESIGN DETAILS A8.35 4 TYP. A8.35 4 TYP. 1" GYP. BD. SHAFT WALL LINER 1" GYP. BD. SHAFT WALL LINER 1" GYP. BD. SHAFT WALL LINER (E) SLAB, S.S.D PER PLAN WALL TYPE PER PLAN WALL TYPE FIRE SEALANT AT END CONDITIONS, TYP. PER PLAN WALL TYPE PER PLAN WALL TYPE SHAFT 3M 2HR DUCT WRAP, TYP. 3M 2HR DUCT WRAP, TYP. 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 9/ 1 6 / 2 0 2 4 1 1 : 1 8 : 1 5 A M A8.35 SHAFT DETAILS HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTY INVESTMENTS, LLC. SCALE: 1 1/2" = 1'-0"A8 . 3 51SHAFT DETAIL @BLDG D ELEV.&CORRIDOR L3-L5 NO.DATE ISSUES & REVISIONS 02.26.24 BULLETIN 5 07.29.24 BULLETIN 9 SCALE: 1 1/2" = 1'-0"A8 . 3 52SHAFT DETAIL @ BLDG C EAST CORRIDOR L2-L3 SCALE: 1 1/2" = 1'-0"A8 . 3 53BLDG C - E/W SECTION @ SHAFT SCALE: 1 1/2" = 1'-0"A8 . 3 55BLDG C - N/S SECTION @ SHAFT SCALE:NTS A8 . 3 542HR SHAFT WALL/STEEL BEAM INTERSECTION DETAIL 09/16/2024 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 5/8" GWB 4-WAY DIAGONAL BRACE WIRES @ 45°TO STRUCTURE ABOVE @ 12'-0" O.C. EACH WAY HANGER WIRE 1-1/2" CROSS CHANNELS MTL. STUD, COMPRESSION STRUTS TO CEILING ABOVE @ 12'-0" O.C. EACH WAY NOTE: NO FRAMING OR HANGERS TO BE IN CONTACT WITH MECHANICAL OR ELECTRICAL EQUIPMENT. 7/8" FURRING CHANNELS TRACKS SCREWED TO CARRYING CHANNELS DESIGN PER ASTM C754 FLOOR/CEILING ASSEMBLY STRUCTURE ABOVE 1/2" ROUND RIGID STEEL TUBING (ADJUSTABLE RESISTANCE STRUT @ 144 SF MAXIMUM) 12 GA. GALVANIZED WIRE TO STRUCTURE ABOVE (4) WAYS @ 45° DEGREE ANGLES SET SCREW 3/4" ROUND RIGID STEEL TUBING NOTCHED @ RUNNER CEILING TILE MAIN RUNNERS NOTES: 1. WHERE CEILING CAVITY EXCEEDS 4'-0", USE 25 GA. 2-1/2" STUD AS COMPRESSION STRUT. 2. INSTALL CEILING PER ICC-ESR #1308 L/ R R A T I O N O T T O E X E E D 2 0 0 VA R I E S 4 ' - 0 " - 7 ' - 0 " .3" SEE NOTE MINIMUM (3) TURNS IN 1-1/2" TYP CROSS TEE MINIMUM (4) TURNS IN 1-1/2" TYP SEE NOTE SEE NOTE 45° 2" MAX 4 2 11 SEE NOTE VIEW SHOWING LATERAL BRACING CLUSTER AND SUSPENSION WIRENOTES: 1. STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS TEE AND SPLAYED 90° FROM EACH OTHER @ 45° MAX ABOVE HORIZONTAL CLUSTERS PLACED 12'-0" O.C. x 8'-0" O.C. AND 4'-0". MAX RESPECTIVELY FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. 2. SUSPENSION WIRE: 12 GAUGE GALVANIZED SOFT ANNEALED MILD STEEL WIRE SECURED TO MAIN RUNNER WITHIN 2" OF CROSS TEE AND SPACED 4'-0" O.C. MAX EACH WAY. 3. PROVIDE COMPRESSION STRUTS (PER ICC-ESR #1308) AT SUSPENDED CEILING SYSTEM. FOR MORE INFORMATION REFER TO DETAIL 8. 4. SUSPENDED CEILING SYSTEM TO COMPLY WITH I.B.C. 8039.1.1 5. USE ONLY HEAVY DUTY T-BAR GRID SYSTEM 6. AS AN ALTERNATIVE TO THE DIAGONAL SPLAY WIRES SPECIFIED ABOVE, CEILINGS MAY USE RIGID BRACES. BRACES SHALL BE ATTACHED TO THE RIGID AND TO THE STRUCTURE ABOVE IN A MANNER TO LIMIT LATERAL DEFLECTIONS AT THE POINT OF ATTACHMENT TO THE CEILING TO LESS THAN 1/4 INCH FOR THE LATERAL LOADS EXPECTED FOR THE SYSTEM. ASCE SECTION 9.6.2.6.2.2 MAIN RUNNERS 4 NOTE: 1. FOR SUPPORT OF LIGHT FIXTURE, SEE ELEC DWGS. 2. THE SUSPENDED CEILING SYSTEM TO MEET ICC REPORT APPROVAL 1308. 3. DESIGN BUILD BY CONTRACTOR 4. SEE DETAIL 3&7/A8.51 FOR SUSPENDED CEILING SUPPORT 12 ' - 0 " 1 2 ' - 0 " 4 ' - 0 " MAX. 4' - 0" MAX. 12' - 0" 12' - 0" MAXIMUM DISTANCE FROM WALLS OR PARTITIONS - 12 GA. HANGER WIRE FACE OF WALLCL 8" MAX. MAIN OR CROSS RUNNER ACT PANEL IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 0.75-IN. CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE. 2" WIDE MIN. WALL ANGLE, ATTACH AT EACH STUD BACK OF HOUSE MI N . ( 3 ) T I G H T TU R N S I N 1 - 1 / 2 " CL 3/4" 5/8" GYP. BD. 2 1/2" MTL. STUDS AT 24" O.C. 20 GA. PROVIDE BRACING AS REQUIRED 5/8" GYP. BD. SEE RCP FOR HEIGHTS WHERE OCCURS 1" CEILING REVEAL TRIM 700 S FLOWER STREET, SUITE 5 2 0 w w w . a x i s g f a . c o m T 3 1 0 . 2 0 9 . 7 5 2 0 F 3 1 0 . 2 0 9 . 7 5 1 6 L O S A N G E L E S, C A 9 0 0 1 7 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 11 / 2 5 / 2 0 2 5 1 0 : 1 0 : 5 5 A M A9 CEILING DETAILS (TI) HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT SUSPENDED CEILlNG MINIMUM REQUIREMENT: (ASCE 7-16 SECTION 13.5.6.2.2 SEISMIC DESIGN) SEISMIC DESIGN CATEGORIES D THROUGH F. SUSPENDED CEILINGS IN SEISMIC DESIGN CATEGORIES D, E, AND F SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ASTM C635, ASTM C636, AND THE CISCA FOR SEISMIC ZONES 3-4 AS MODIFIED BY THE FOLLOWING: A. A HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED. B. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2.0 IN. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 0.75 IN. CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE. C. FOR CEILING AREAS EXCEEDING 1,000 SF HORIZONTAL RESTRAINT OF THE CEILING TO THE STRUCTURAL SYSTEM SHALL BE PROVIDED. THE TRIBUTARY AREAS OF THE HORIZONTAL RESTRAINTS SHALL BE APPROXIMATELY EQUAL. EXCEPTION: RIGID BRACES ARE PERMITTED TO BE USED INSTEAD OF DIAGONAL SPLAY WIRES. BRACES AND ATTACHMENTS TO THE STRUCTURAL SYSTEM ABOVE SHALL BE ADEQUATE TO LIMIT RELATIVE LATERAL DEFLECTIONS AT POINT OF ATTACHMENT OF CEILING GRID TO LESS THAN 0.25 IN. FOR THE LOADS PRESCRIBED IN SECTION 13.3.1. D. FOR CEILING AREAS EXCEEDING 2,500 SF, A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2,500 SF SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSES ARE PERFORMED OF THE CEILING BRACING SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONSTRATE CEILING SYSTEM PENETRATIONS AND CLOSURE ANGLES PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERAL DISPLACEMENT. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLES IN ACCORDANCE WITH ITEM B AND HORIZONTAL RESTRAINTS OR BRACING IN ACCORDANCE WITH ITEM C. E. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 IN. OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 IN. IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, A SWING JOINT THAT CAN ACCOMMODATE 1 IN. OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF THE SPRINKLER HEAD EXTENSION. F. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. G. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. H. SUSPENDED CEILINGS SHALL BE SUBJECT TO THE SPECIAL INSPECTION REQUIREMENTS OF SECTION 11A.1.3.9 OF THIS STANDARD. SUSPENDED CEILlNG SYSTEM NOTES: PARTITIONS THAT ARE TIED TO THE CEILING AND ALL PARTITIONS GREATER THAN 6'-0" IN HEIGHT SHALL BE LATERALLY BRACED TO THE STRUCTURE. BRACING SHALL BE INDEPENDENT OF THE CEILING SPLAY BRACING SYSTEM. ALL MAIN BEAMS ARE TO BE HEAVY DUTY (HD). ALL CROSS TEES SHALL BE CAPABLE OF CARRYING THE DESIGN LOAD WITHOUT EXCEEDING DEFLECTION EQUAL TO 1/360 OF ITS SPAN. THESE RECOMMENDATIONS ARE INTENDED FOR SUSPENDED CEILINGS INCLUDING GRID, PANEL OR TILE, LIGHT FIXTURES AND AIR TERMINALS WEIGHING NO MORE THAN 4 POUNDS PER SF. ALL WIRE TIES ARE TO BE (3) TIGHT TURNS AROUND ITSELF WITHIN 3”. 12 GA HANGER WIRE SPACED 4'-0" OC. CHANGES IN CEILING PLANES WILL REQUIRE POSITIVE BRACING. CEILINGS CONSTRUCTED OF LATHE AND PLASTER OR GWB, SCREW OR NAIL ATTACHED TO SUSPENDED MEMBERS THAT SUPPORT A CEILING ON ONE LEVEL EXTENDING FROM WALL TO WALL SHALL BE EXEMPT FROM THE LATERAL FORCE BRACING REQUIREMENTS. LATERAL FORCE BRACING IS THE USE OF VERTICAL STRUTS (COMPRESSION POSTS) AND SPRAY WIRES. LATERAL FORCE BRACING IS REQUIRED FOR CEILINGS OVER 1000 SF AND NOT REQUIRED FOR CEILINGS LESS THAN 1,000 SF PROVIDED THEY ARE SURROUNDED BY FOUR WALLS AND BRACED TO STRUCTURE. LATERAL FORCE BRACING SHALL BE 12'-0”OC MAX AND BEGIN NO FARTHER THAN 6'-0” FROM WALLS. SPLAY WIRES ARE TO BE (4) 12 GA WIRES ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED 90◦FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45◦FROM THE PLANE OF THE CEILING. SPLAY WIRES ARE TO BE WITHIN 2”OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPEND CEILING. RIGID BRACING MAY BE USED IN LIEU OF SPLAY WIRES CEILINGS WITH PLENUMS LESS THAN 12”TO STRUCTURE ARE NOT REQUIRED TO HAVE LATERAL FORCE BRACING. VERTICAL STRUTS MUST BE POSITIVELY ATTACHED TO THE SUSPENSION SYSTEMS AND THE STRUCTURE ABOVE. VERTICAL STRUT MAY BE EMT CONDUIT, METAL STUDS OR A PROPRIETARY COMPRESSION POST. WALL MOLDINGS (PERIMETER CLOSURE ANGLES) ARE REQUIRED TO HAVE A HORIZONTAL FLANGE 2”WIDE, UNLESS ALTERNATE METHODS ARE APPROVED PRIOR TO INSTALLATION BY THE LOCAL BUILDING DEPARTMENT AND THE DESIGNER OF RECORD. ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE WALL MOLDING, THE OTHER END SHALL HAVE A ¾”CLEARANCE FROM THE WALL AND FREE TO SLIDE. THE GRID SHALL BE ATTACHED AT TWO ADJACENT WALLS (POP RIVETS OR APPROVED METHOD). THERE SHALL BE A MINIMUM ¾”CLEARANCE FROM THE END OF THE GRID SYSTEM AT UNATTACHED WALLS. SPREADER (SPACER) BARS OR OTHER MEANS APPROVED BY LOCAL BUILDING DEPARTMENT SHALL BE USED TO PREVENT THE ENDS OF THE MAIN BEAMS AT PERIMETER WALLS FROM SPREADING OPEN DURING A SEISMIC EVENT. PERIMETER WIRES SHALL NOT BE IN LIEU OF SPREADER BARS. WIRE TYING IS AN ACCEPTABLE ALTERNATIVE TO SPREADER BARS. SPREADER BARS ARE NOT REQUIRED IF A 90◦INTERSECTING CROSS OR MAIN IS WITHIN 8”OF THE PERIMETER WALL. HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED. HANGER WIRES SHALL BE 12 GA AND SPACED 4'-0”OC. OR 10 GA SPACED 5'-0”OC. ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. FOR ESSENTIAL FACILITIES, HANGER WIRE CONNECTIONS MUST BE CAPABLE OF CARRYING 200 POUNDS AND BRACING (SPLAY) WIRES SHALL BE CAPABLE OF CARRYING 440 POUNDS. SHOT-IN ANCHORS IN CONCRETE ARE NOT PERMITTED FOR BRACING WIRES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD, WITH A SAFETY FACTOR OF 2. WHICHEVER IS GREATER. POWER DRIVEN FASTENERS MUST BE APPROVED FOR THE APPROPRIATE LOADING. TERMINAL ENDS OF EACH MAIN BEAM AND CROSS TEE MUST BE SUPPORTED WITHIN 8” OF EACH WALL WITH A PERIMETER WIRE. LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL HAVE ONE 12 GA HANGER WIRE CONNECTED FROM THE FIXTURE TO THE STRUCTURE ABOVE. THIS WIRE MAY BE SLACK. LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS SHALL HAVE TWO 12 GA WIRES ATTACHED AT OPPOSING CORNERS OF THE LIGHT FIXTURES TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. SUSPENDED CEILlNG SYSTEM NOTES (CONTINUED): LIGHT FIXTURES WEIGHING MORE THAN 56 POUNDS SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE. THESE WIRES MUST BE TAUT. PENDANT MOUNTED FIXTURES SHALL BE DIRECTLY SUPPORTED FROM THE STRUCTURE ABOVE USING A 9 GA WIRE OR AN APPROVED ALTERNATE SUPPORT WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. TANDEM FIXTURES MAY UTILIZE COMMON WIRES. MECHANICAL TERMINALS OR SERVICES WEIGHING 20 POUNDS BUT NOT MORE THAN 56 POUNDS MUST HAVE TWO 12 GA. WIRES CONNECTING THEM TO THE CEILING SYSTEM HANGERS OR THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. MECHANICAL TERMINALS OR SERVICES WEIGHING MORE THAN 56 POUNDS MUST BE INDEPENDENTLY SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE. THESE WIRES MUST BE TAUT. FOR CEILING AREAS EXCEEDING 2,500 S.F., A SEISMIC SEPARATION JOINT OR FULL HEIGHT WALL PARTITION THAT BREAKS THE CEILING SHALL BE PROVIDED UNLESS ANALYSES ARE PERFORMED OF THE CEILING BRACING SYSTEM. CLOSURE ANGLES AND PENETRATIONS TO PROVIDE SUFFICIENT CLEARANCE. SPECIAL INSPECTIONS ARE PERIODICALLY REQUIRED TO VERIFY THAT THE CEILING SYSTEM COMPLIES WITH THE INSTALLATION INSTRUCTIONS AND WITH THE APPROVED CONSTRUCTION DOCUMENTS. REFER TO OWNER'S QUALITY ASSURANCE PLAN. CONTACT LOCAL BUILDING DEPARTMENT. FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. FLEXIBLE HEAD DESIGN THAT CAN ACCOMMODATE 1”FREE MOVEMENT SHALL BE PERMITTED AS AN ALTERNATE. ONE HOUR CORRIDOR NOTES: INTERIOR OPENINGS FOR OTHER THAN DOORS OR DUCTS SHALL BE PROTECTED BY FIXED GLAZNG LISTED AND LABELED FOR A FIRE PROTECTION RATING OF AT LEAST THREE FOURTHS HOUR IN ACCORDANCE WITH CBC SECTION 715.5. PENETRATIONS IN FIRE-RESISTIVE WALLS SHALL COMPLY WITH CBCB SECTIONS 715 AND 716. CABINETS SUCH AS RECESSED ELECTRICAL PANELS, FIRE HOSE CABINETS, AND RECESS FIRE EXTINGUISHER CABINETS CONSTRUCTED OF STEEL ARE PERMITTED, PROVIDED THAT THE OPENINGS ON THE FIRE RATED CORRIDOR ARE SEALED WITH APPROVED SEALANT MATERIAL TO PREVENT THE PASSAGES OF SMOKE. OTHER CABINETS SHOULD BE INSTALLED OR RECESSED SO THAT THERE IS NO REDUCTION IN THE FIRE RATING OF THE WALL, OR OPENING WHICH WOULD ALLOW SMOKE PASS. THIS WOULD MEAN THAT THE CABINET MUST BE SURROUNDED WITH MATERIAL WHICH PROVIDES THE EQUIVALENT OF ONE-HOUR FIRE RESISTANCE. SCALE: 1" = 1'-0" A91DROP CEILING DETAIL SCALE: 3" = 1'-0" A912SUSPENDED CLNG BRACING SUPPORT SCALE: 3" = 1'-0" A94SUSPENDED CLNG BRACING ISOMETRIC SCALE: 1/8" = 1'-0" A98SUSPENDED CEILING BRACING PLAN SCALE: 1 1/2" = 1'-0" A97SUSPENDED CEILING WALL SUPPORT A SCALE: 1 1/2" = 1'-0" A911SOFFIT TRANSITION NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET C-18505NO. REN.09/30/27 BLDG. C (E) LEVEL 212' - 11" BLDG. C & D L E V E L 1 EL +0.00' BLDG. C (E) LEVEL 2EL +12.92'BLDG.C (E) LEVEL 3EL +25.33'BLDG.C (E) ROOFEL +37.70'BLDG.C (E) BASEMENTEL -12.00' BLDG. D L E V E L 1 EL +0.00' BLDG. D L E V E L 2 EL +10.00 ' BLDG. D L E V E L 3 EL +19.50 ' BLDG. D LEVEL 4EL +29.50'BLDG. D LEVEL 5EL +39.50'BLDG. D LEVEL 6EL +49.50'BLDG. D PLANNING HEIGHTLIMITEL +63.40'BLDG. D ROOFEL +59.50'BLDG. C (E) ROOF H.P.(T.O.C)EL +38.83'BLDG. C ROOFTOP PATIOEL +39.33' FOOD SERVICE EQUIPMENT BY OTHERS TILE WALL BASE BLACK FRP @ EMPLOYEE SIDE OF WALL AND UNDERSIDE OF TOP 2" CONTINUOUS 1/8" BENT PLATE COUNTER SUPPORT. ATTACH TO STUDS. PAINT BLACK,12" HIGH AT WALL, 17 1/2" WIDE UNDER COUNTER WITH TUBE STEEL CONTINUOUS 1-1/4" x 1/8" TUBE CONTINUOUS LED STRIP AND CHANNEL - WALL GRAZE 1' - 0 " 1 1/4" x 1/8" TUBE @ 3'-0" O.C. 1' - 5 3/8"3" 11"1' - 7" SS-100.100 SF-100.10045 DEGREE MITER WITH EASED EDGE AT CORNERS (TYP) WALL TILE TILE WALL BASE 5/8" GYP BOARD OVER 3-5/8" METAL STUD FRAMING. REFER TO ARCHITECTURAL BLACK FRP CONTINUOUS 1/8" BENT PLATE COUNTER SUPPORT. ATTACH TO STUDS. PAINT BLACK, 12" HIGH AT WALL, 17" WIDE UNDER COUNTER WITH TUBE STEEL CONTINUOUS 1 1/4" x 1/8" TUBE CONTINUOUS LED STRIP AND CHANNEL - WALL GRAZE 2' - 1 0 " 1' - 5 3/8"3" 1' - 7"11" SS-100.100 45 DEGREE MITER WITH EASED EDGE AT CORNERS (TYP) SF-100.100 WALL TILE 2' - 6 1 / 2 " BS-100.100 ID5.11 1 4 3 2 15' - 7" 10 ' - 1 1 " 1' - 7 " 11 " 8' - 5 " 13' - 1"11"1' - 7" 2 ID10.11 3 ID10.11 2 ID10.115 ID10.116 2' - 8 " 4' - 2 1 / 2 " 2' - 9 1 / 2 " 7' - 0 " ID10.11 7 ID10.118 CONTINUOUS STRIP LIGHT SEE LIGHTING DRAWINGS FINISH CEILING 1 1 / 2 " 2' - 6 1 / 2 " 9' - 8" 7' - 0"AFF 2" 2" 2" 2" 10 1 / 4 " 9 1/4"2 1/2" ADJUSTABLE SHELF WITH P-LAM FINISH STAINED HARDWOOD CASEWORK FACE FRAME FINISH TO MATCH CASEWORK INTERIOR FINISH TO BE P-LAM STAINED HARDWOOD CASEWORK FACE FRAME FINISH TO MATCH WD-100.100 WD-100.100 WD-100.100 CONTINUOUS STRIP LIGHT SEE LIGHTING DRAWINGS PLYWOOD WITH STAINED VENEER FACE FINISH TO MATCH PLYWOOD WITH STAINED VENEER FACE FINISH TO MATCH WD-100.100 STAINED HARDWOOD CORNER FINISH TO MATCH WD-100.100 1' - 3" WD-100.100 CONTINUOUS STRIP LIGHT SEE LIGHTING DRAWINGS ADJUSTABLE SHELF WITH P-LAM FINISH FINISH CEILING STAINED HARDWOOD CASEWORK FACE FRAME FINISH TO MATCH 9' - 8" 2' - 6 1 / 2 " 1 1 / 2 " 7' - 0"AFF CASEWORK INTERIOR FINISH TO BE P-LAM STAINED HARDWOOD CASEWORK FACE FRAME FINISH TO MATCH PLYWOOD WITH STAINED VENEER FACE FINISH TO MATCH WD-100.100 WD-100.100 PLYWOOD WITH STAINED VENEER FACE FINISH TO MATCH WD-100.100 STAINED HARDWOOD CORNER FINISH TO MATCH WD-100.100 1' - 0" MATCH COUNTER BELOW 1' - 3" 1" = 1'-0"7 VIP BAR DIE - ELEVATION 1" = 1'-0"5 VIP BAR - SECTION 1/2" = 1'-0"1 VIP BAR- PLAN 1/2" = 1'-0"2 VIP CASEWORK - SECTION 1/2" = 1'-0"3 VIP CASEWORK - SECTION 1" = 1'-0"8 VIP CASEWORK - SECTION 1" = 1'-0"6 VIP CASEWORK - SECTION A 3D VIEW ENLARGED VIP 1 1 1 1 1 1 2 2 ENTIRE SHEET REVISED 2 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVEARCADIA, CA 91006 NO.DATE ISSUES & REVISIONS 06.19.25 BID SET2 HILTON ARCADIA 123 W HUNTINGTON DR.ARCADIA, CA91007 JAPANESE RESTAURANT BUNNYFiSHs t u d i o702 241 9751 ID10.11 24-0303 27 " M I N 27 " M I N 11.26.25 PERMIT SET C-18505NO. REN.09/30/27 NOTE: CONFIRM FINISH WITH INTERIOR DRAWINGS 11.5 D C.4 C ID5.10 9 EQ EQ 4' - 11" ID10.12 2 ID10.123 HORIZONTAL WOOD SLATS ABOVE HORIZONTAL WOOD SLATS ABOVE HORIZONTAL WOOD SLATS ABOVE TYP. ID10.12 5 ID10.125 ID10.12 6 VI F 6' - 0 " 1' - 3 " 11 ' - 1 " 1' - 3 " 18 ' - 1 1 " 1' - 7 " ID10.127 SIM 5 5 DC.4C ID10.129 EXISTING STRUCTURAL BEAM G-100.100 OPEN TO BEYOND OPEN WD-100.100 WD-100.100 WD-100.100 WD-100.100 WD-100.100 WD-100.100 WD-100.100 OPEN TO BEYOND 10' - 0" 0' - 0" 12' - 6" D C.4 C EXISTING STRUCTURAL BEAM OPEN G-100.100 WD-100.100 WD-100.100 WD-100.100 WD-100.100 WD-100.100 EQ EQ OPEN TO BEYOND OPEN TO BEYOND 9' - 0" 11' - 0" 0' - 0" 6" 3"4"3"4"3"4"3"4"3"4"3"4"3"4"3"4"3" 2' - 4 3 / 4 " OVER MDF. TOTAL THICKNESSS WITH VENEER = 3/4" WOOD "SLAT” FABRICATED FROM 1/2” THICK MAPLE LUMBER WD-100.100 WOOD BLOCKING AS REQUIRED 4' - 11" 11.5 D 3"4"3"4"3"4"3"4"3"4"3"4"3"4"3"4"3" 4' - 11" 6" 5 3 / 8 " 6" 5 3 / 8 " 6" 6" 1' - 8 1 / 2 " 2 1 / 4 " WOOD "SLAT” FABRICATED FROM 1/2” THICK MAPLE LUMBER 2' - 4 3 / 4 " 12 WOOD SCREEN, 3" x 6" VERTICAL WOOD "SLATS" @ 7" O.C. 3"4"3"4"3"4"3"4"3"4"3"4"3"4"3"4"3" 4' - 11" 6" 11.5 3"4"3"4"3"4"3"4"3"4"3"4"3"4"3"4"3" 6" 1/2"2"1/2" 1/ 2 " 5" 1/ 2 " BLOCKING AS REQURED 1/2" MAPLE BOX BEAM OVER PLYWOOD. TOTAL THICKNESSS WITH VENEER = 3/4" TO MATCH ALIGN WD-100.100 6" TY P ID10.1210 2' - 3 " 2" 1' - 1 0 " 2" 3' - 0 " 2" 2' - 4 1 / 2 " 2" CONTINOUS 2"x2" (ACTUAL DIMENSION) WOOD SHIM/SLAT SUPPORT HARDWOOD MAPLE FINISH TO MATCH SLAT 9' - 0 " 9' - 6 " 9"1' - 0 3/8" 9" R 1' - 0 " PITTCON INDUSTRIES OUTSIDE CORNER SO-LRT - 9" RADIUS CONTINOUS LED LIGHT STRIP 3"x4" WOOD SLAT CONTINOUS 2"x2" WOD SHIM/SLAT SUPPORT HARDWOOD MAPLE FINISH TO MATCH SLAT EXISTING WALL TO REMAIN 1/4" = 1'-0"1 SLAT ENCLOSURE - PLAN A SLAT ENCLOSURE - 3D VIEW 1/4" = 1'-0"2 SLAT ENCLOSURE - LEFT ELEVATION 1/4" = 1'-0"3 SLAT ENCLOSURE - RIGHT ELEVATION 1" = 1'-0"5 VERTICAL SLAT DETAIL - DOUBLE 1" = 1'-0"6 VERTICAL SLAT DETAIL @ GRID D-11.5 1" = 1'-0"7 SCREEN WALL AT BANQUETTE 1" = 1'-0"4 WOOD TRELLIS SECTION 1/2" = 1'-0"9 SLAT ENCLOSURE - TYPICAL SECTION 1/2" = 1'-0"8 SECTION @ ENTRY WALL 1" = 1'-0"10 ENTRY WALL @ CEILING 1 1 1 2 2 2 2 2 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVEARCADIA, CA 91006 NO.DATE ISSUES & REVISIONS 06.19.25 BID SET2 HILTON ARCADIA 123 W HUNTINGTON DR.ARCADIA, CA91007 JAPANESE RESTAURANT BUNNYFiSHs t u d i o702 241 9751 ID10.12 24-0303 DETAIL B DETAIL B BLOCKING ATTACHED TO METAL STUD BACKING W/ (3) #10 SMS (2) #6 WOOD SCREW 2" PEN EA FACE (2) #6 WOOD SCREW 2" PEN EA FACE @ 16" OC #10 SMS TO METAL STUD BACKING @ 16" OC TYP AT BEAMAT CENTERSLATS TYP AT CORNERSLATS MAY NEED HANGER WIRE TO SUPPORT LARGE SPAN ~ 6' OC #6 WOOD SCREW AT EVERY BOX BEAM FASTEN SIDES OF BEAM TO BLOCKING 12 GA WIRE HANGER W/3 TURNS EA END WIRE HANGING BRACING METAL STUD WALL PER ARCH W/BACKING PER STRUCT AS REQUIRED #6 WOOD SCREW TO CEILING CLIPHANGER AND BRACE CONN TO STRUCTURE SEE DETAIL B NOTE: CONFIRM FINISH WITH INTERIOR DRAWINGS9"1' - 0 3/8" 9" R 1' - 0 " PITTCON INDUSTRIES OUTSIDE CORNER SO-LRT - 9" RADIUS CONTINOUS LED LIGHT STRIP 3"x4" WOOD SLAT CONTINOUS 2"x2" WOD SHIM/SLAT SUPPORT HARDWOOD MAPLE FINISH TO MATCH SLAT EXISTING WALL TO REMAIN 1.5" DETAIL B TYP ATSOFFIT METAL STUD SOFFIT PER ARCH W/BACKING PER STRUCT AS REQUIRED BLOCKING ATTACHED TO METAL STUD BACKING W/ (3) #10 SMS WOOD "SLAT" FABRICATED FROM MAPLE VENEERED FIRE-RETARDANT PARTICLE BOARD WOOD "SLAT" FABRICATED FROM MAPLE VENEERED FIRE-RETARDANT PARTICLE BOARD WOOD "SLAT" FABRICATED FROM MAPLE VENEERED FIRE-RETARDANT PARTICLE BOARD FABRICATED FROM MAPLE VENEERED FIRE-RETARDANT PARTICLE BOARD FABRICATED FROM MAPLE VENEERED FIRE-RETARDANT PARTICLE BOARD WOOD BLOCKING/FURRING SUPPORT TO BE FRTW AS REQUIRED. CBC 603.1,1.1 OR VOID FILLED WITH NONCOMBUSTIBLE MATERIAL. CBC 803.15.2. TYPICAL FOR ALL. 11.26.25 PERMIT SET C-18505NO. REN.09/30/27 H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 3 H i l t o n A r c a d i a H o t e l R e s t a u r a n t ( d o n o t d e l e t e ) \ 3 _ D r a w i n g s \ D w g s - 0 3 \ 1 9 - 0 2 8 3 - 0 3 _ B l d g C _ S 1 0 0 S T R U C T U R A L N O T E S & A B B R E V I A T I O N S . d w g P L O T T E D B Y : Je s s e D e l g a d o O N : No v e m b e r 2 5 , 2 0 2 5 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 S100 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 08.27.25 TI PLAN CHECK (2ND) LA21.522 STRUCTURAL NOTES AND ABBREVIATIONS LONG BEACH • SAN DIEGO Project: LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 STRUCTU RAL E N GI N SREE 19-0283-03 S No.4101IS G E R OF C TA ST E R EF D P R O TE E I REE N AINRFOILA A ONS L E N G I KE N N E T H D.O'DEL L U R A LTSRUCTPR O G R E S S - NOT F O R P L A N REV I E W 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET SYMBOLS #POUND, NUMBER, QUANTITY @ AT <LESS THAN >GREATER THAN ±PLUS OR MINUS °DEGREE Ø DIAMETER ABBREVIATIONS AB ANCHOR BOLT ABV ABOVE ADDL ADDITIONAL ADH ADHESIVE ADJ ADJACENT ALT ALTERNATE ALUM ALUMINUM ANCH ANCHOR, ANCHORAGE APPROX APPROXIMATE, APPROXIMATELY ARCH ARCHITECT, ARCHITECTURAL APGD AUGER PRESSURE GROUTED DISPLACEMENT ATR ALL-THREAD ROD BEL BELOW BLDG BUILDING BLKG BLOCKING, BLOCK BM BEAM BN BOUNDARY NAIL BOT BOTTOM B/O BOTTOM OF BRG BEARING BS BOUNDARY SCREW BSMT BASEMENT BTWN BETWEEN CALCS CALCULATIONS CANT CANTILEVER CFRP CARBON FIBER REINFORCED POLYMER CG CENTER OF GRAVITY CIP CAST IN PLACE CJ CONTROL JOINT CL CENTERLINE CLG CEILING CLR CLEAR, CLEARANCE CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECT, CONNECTION CONT CONTINUOUS CJP COMPLETE JOINT PENETRATION COORD COORDINATE CSK COUNTERSINK, COUNTERSUNK CTR CENTER d PENNY (NAIL SIZE) db BAR DIAMETER (REBAR) DBL DOUBLE DCW DEMAND CRITICAL WELD DET DETAIL DFL DOUGLAS FIR LARCH DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DIR DIRECTION DIST DISTANCE DN DOWN DL DEAD LOAD DO DITTO DWG DRAWING (E) EXISTING EA EACH EBF ECCENTRIC BRACED FRAME EF EACH FACE ELEC ELECTRICAL ELEV ELEVATION, ELEVATOR EMB EMBED, EMBEDDED, EMBEDMENT EMBED EMBED, EMBEDDED, EMBEDMENT EN EDGE NAIL ENGR ENGINEER EOR ENGINEER OF RECORD EQ EQUAL, EQUALLY EQUIP EQUIPMENT ES EDGE SCREW, EACH SIDE EW EACH WAY EXC EXCAVATE, EXCAVATION EXP EXPANSION EXT EXTERIOR FDN FOUNDATION FIN FINISH FLNG FLANGE FLR FLOOR FN FIELD NAIL F/O FACE OF FRMG FRAMING FS FIELD SCREW FTG FOOTING FTR FULLY-THREADED ROD GA GAUGE GALV GALVANIZE GC GENERAL CONTRACTOR GLB GLUED-LAMINATED BEAM GR GRADE GB GRADE BEAM HD HOLDOWN HDR HEADER HEX HEXAGONAL HGR HANGER HT HEIGHT HORIZ HORIZONTAL HR HOUR (FIRE RATING) I/F INSIDE FACE ID INSIDE DIAMETER INFO INFORMATION INSP INSPECTION INT INTERIOR, INTERSECTION INV INVERT, INVERTED IOR INSPECTOR OF RECORD JST JOIST JT JOINT K KIPS (1000#) KB3 HILTI KWIK BOLT 3 (ANCHOR) KB-TZ2 HILTI KWIK BOLT TZ2 (ANCHOR) KP KING POST KSF KIPS PER SQUARE FOOT KSI KIPS PER SQUARE INCH ld DEVELOPMENT LENGTH ldh HOOK DEVELOPMENT LENGTH LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LOCS LOCATIONS LONG LONGITUDINAL ls LAP SPLICE LENGTH LTWT LIGHTWEIGHT MANUF MANUFACTURER MAX MAXIMUM MECH MECHANICAL MEZZ MEZZANINE MFR MANUFACTURER MHP MHP STRUCTURAL ENGINEERS MID MIDDLE MIN MINIMUM MISC MISCELLANEOUS (N)NEW N/A NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE O/F OUTSIDE FACE OC ON CENTER OD OUTSIDE DIAMETER OH OPPOSITE HAND OP OPERATING OPNG OPENING OPP OPPOSITE PARA PARALLEL PERP PERPENDICULAR PEN PENETRATION PL PLATE, PROPERTY LINE PLF POUNDS PER LINEAR FOOT PLY PLYWOOD PJP PARTIAL JOINT PENETRATION PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POST-TENSIONED (CONCRETE) PT PRESSURE-TREATED (WOOD) QTY QUANTITY R RADIUS RAD RADIUS REF REFER TO, REFERENCE REINF REINFORCING REQD REQUIRE, REQUIRED SCHED SCHEDULE SEOR STRUCTURAL ENGINEER OF RECORD SHTG SHEATHING SIM SIMILAR SIMP SIMPSON STRONG-TIE COMPANY SMRF SPECIAL MOMENT-RESISTING FRAME SMS SHEET METAL SCREW SOG SLAB ON GRADE SQ SQUARE SS STAINLESS STEEL STAGG STAGGER STD STANDARD STIFF STIFFEN, STIFFENER STIRR STIRRUP STL STEEL STRUC STRUCTURAL SW SHEAR WALL SYM SYMMETRICAL T&B TOP & BOTTOM TBD TO BE DETERMINED TEMP TEMPERATURE, TEMPORARY THK THICK, THICKNESS THRU THROUGH T/O TOP OF TRANS TRANSVERSE TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W/WITH W/O WITHOUT WP WORK POINT WT WEIGHT WWF WELDED WIRE FABRIC STRUCTURAL STEEL SHAPES Cx STANDARD CHANNEL HSS HOLLOW STRUCTURAL SECTIONS Lx ANGLE MCx MISCELLANEOUS CHANNEL Mx M SHAPES STD PIPE STANDARD PIPE Sx S SHAPES WTx, STx STRUCTURAL TEES Wx W SHAPES X-STRG EXTRA STRONG PIPE XX-STRG DBL EXTRA STRONG PIPE ABBREVIATIONS: CODES/INSTITUTIONS/ASSOCIATIONS ACI AMERICAN CONCRETE INSTITUTE AF&PA (NDS) AMERICAN FOREST & PAPER ASSOCIATION (NDS) AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION AISI AMERICAN IRON AND STEEL INSTITUTE APA-EWA APA-ENGINEERED WOOD ASSOCIATION ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS AWS AMERICAN WELDING SOCIETY CBC CALIFORNIA BUILDING CODE CRSI CONCRETE REINFORCING STEEL INSTITUTE DSA DIVISION OF THE STATE ARCHITECT IBC INTERNATIONAL BUILDING CODE NDS NATIONAL DESIGN SPECIFICATIONS SDI STEEL DECK INSTITUTE SJI STEEL JOIST INSTITUTE SSMA STEEL STUD MANUFACTURERS ASSOCIATION GENERAL STRUCTURAL NOTES: 1.DESIGN CRITERIA: THE FOLLOWING DESIGN PARAMETERS HAVE BEEN USED IN THE DESIGN OF THE STRUCTURAL, AND WHERE APPLICABLE, NON-STRUCTURAL SYSTEMS REPRESENTED IN THESE STRUCTURAL DRAWINGS. A.CODE OF RECORD: 2019 EDITION, CALIFORNIA BUILDING CODE B.AUTHORITY HAVING JURISDICTION:CITY OF ARCADIA BUILDING DEPARTMENT (REFERENCE TO THE “AUTHORITY HAVING JURISDICTION” OR “GOVERNING AGENCY” THROUGHOUT THESE STRUCTURAL DRAWINGS SHALL BE CONSIDERED TO BE THE AUTHORITY LISTED ABOVE.) C.BUILDING RISK CATEGORY:II D.BUILDING C DESIGN LOADS (VERTICAL/GRAVITY): ·ROOF:DL: 26 PSF LL: 20 PSF ·TYP FLOOR:DL: 62 PSF LL: 40 PSF (40 PSF CORRIDORS, 100 PSF STAIRS, ETC.) THESE LOAD VALUES REPRESENT THE ANTICIPATED DEAD LOADS AND ALLOWABLE SUPERIMPOSED LIVE LOADS FOR WHICH THE STRUCTURE HAS BEEN DESIGNED, ASSUMING THE NOTED MATERIALS STRENGTHS ARE ACHIEVED AND THE STRUCTURE HAS BEEN FULLY ERECTED AND SECURED. MINOR ADJUSTMENTS MAY HAVE BEEN USED FOR SPECIAL DESIGN CASES WHERE MORE REFINED VALUES ARE REQUIRED. D.WIND DESIGN PARAMETERS: ·ULTIMATE (LFRD) DESIGN WIND SPEED (V 3 SEC. GUST):100 MPH ·WIND DIRECTIONALITY FACTOR, (KD):0.85 ·EXPOSURE CATEGORY:C ·TOPOGRAPHIC FACTOR, (KZT):1.00 ·GUST EFFECT FACTOR:0.85 ·ENCLOSURE CLASSIFICATION:ENCLOSED ·INTERNAL PRESSURE COEFFICIENT, (GCPI):+/-0.18 ·ULTIMATE DESIGN WIND PRESSURE: §COMPONENTS AND CLADDING: LESS THAN 10 SQ.FT.: 36 PSF GREATER THAN 100 SQ.FT.: 28 PSF (WIND PRESSURES FOR AREAS IN BETWEEN MAY BE LINEARLY INTERPOLATED) F.SEISMIC DESIGN PARAMETERS: ·SEISMIC SITE CLASS:D ·SITE COEFFICIENTS, SPECTRAL ACCELERATION PARAMETERS: §SS: 1.982g §S1: 0.725g ·DESIGN SPECTRAL ACCELERATION PARAMETERS: §SDS: 1.321 SXS-1N: 1.321 SXS-2N: 1.982 §SD1: 0.822 SXS-1N: 0.822 SXS-2N: 1.233 ·SEISMIC IMPORTANCE FACTOR:1.00 ·SEISMIC DESIGN CATEGORY:D ·RISK CATEGORY:II 2.ASTM DESIGNATIONS, ICC REPORT REFERENCES, AND ALL STANDARDS AND REFERENCED DOCUMENTS SHALL REFER TO THE LATEST EDITIONS AND/OR AMENDMENTS AS ADOPTED BY THE CODE OF RECORD. 3.GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE PROJECT. WHERE SPECIFIC DETAILS ARE NOT PROVIDED, THE GENERAL NOTES AND TYPICAL DETAILS SHALL GOVERN. HOWEVER, WHEN A SPECIFIC DETAIL OR NOTE HAS BEEN PROVIDED, REFERENCED OR CALLED OUT ON PLAN, THAT DETAIL OR NOTE SHALL GOVERN FOR THE SPECIFIC CASE. IN ADDITION, WHEN A DETAIL IS REFERENCED AS SIMILAR (SIM) TO A SPECIFIC DETAIL, OR WHEN IT CAN BE REASONABLY INFERRED THAT A SITUATION IS SIMILAR TO A SPECIFIC DETAIL, THAT SPECIFIC DETAIL SHALL BE ASSUMED TO APPLY UNTIL OTHERWISE DIRECTED BY THE ENGINEER OF RECORD. 4.THESE STRUCTURAL DRAWINGS ARE AN INTEGRAL PART OF, AND RELIANT ON, INFORMATION CONTAINED WITHIN THE ENTIRE SET OF CONSTRUCTION DOCUMENTS PREPARED FOR THE PROJECT. AS SUCH, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS TO REVIEW AND COORDINATE INFORMATION CONTAINED IN THE CIVIL/ARCH/M/E/P AND SPECIALTY CONSULTANT DRAWINGS AND SPECIFICATIONS TO ENSURE A FULL UNDERSTANDING OF THE PROJECT REQUIREMENTS. ANY OMISSIONS AND/OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER AND THE CONTRACTOR SHALL NOT PROCEED WITH THE AFFECTED WORK UNTIL CLARIFICATION AND/OR DIRECTION HAS BEEN GIVEN. 5.PRIOR TO STARTING WORK ON THE PROJECT AND/OR ON A SPECIFIC AREA OF THE PROJECT, THE CONTRACTOR SHALL CHECK ALL DIMENSIONS. DIMENSIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE COORDINATED FROM THE ARCHITECTURAL AND OTHER CONSULTANT DRAWINGS. WHERE DIMENSIONS DIFFER BETWEEN PLANS, THE ARCHITECT AND STRUCTURAL ENGINEER SHALL BE NOTIFIED AND THE CONTRACTOR SHALL NOT PROCEED WITH THE AFFECTED WORK UNTIL DIRECTION HAS BEEN PROVIDED. WRITTEN DIMENSIONS SHALL GOVERN OVER SCALES SHOWN ON THE PLANS. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES. THE ARCHITECTURAL AND MEP DRAWINGS SHALL BE USED FOR THE SIZE AND LOCATION OF ALL OPENINGS (EXCEPT AS SPECIFICALLY CONTROLLED BY THE STRUCTURAL DRAWINGS), INTERIOR NON-BEARING PARTITIONS, CONCRETE CURBS, SLOPES, DEPRESSIONS, CHANGES IN LEVEL, FINISHES, CHAMFERS OR GROOVES, FLOOR AND ROOF DRAINS, INSERTS, SLEEVES, PIPES, CONDUITS AND OTHER NON-STRUCTURAL ITEMS. 7.UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL PLANS OR REFERENCED DETAILS, DO NOT PLACE MECHANICAL, ELECTRICAL (INCLUDING LOW-VOLTAGE AV), AND PLUMBING (MEP) SLEEVES, PIPES, INSERTS OR CONDUIT IN OR THROUGH STRUCTURAL MEMBERS, REGARDLESS OF MATERIAL, WITHOUT PRIOR APPROVAL AND DIRECTION BY THE STRUCTURAL ENGINEER. EXCEPT AS SPECIFICALLY SHOWN ON PLAN, NO STRUCTURAL MEMBER (BEAM, COLUMN, SHEAR WALL, STRUCTURAL SLAB, GRADE BEAM, BRACE, ETC.) SHALL BE CUT, DRILLED, OR NOTCHED WITHOUT PRIOR AUTHORIZATION AND DIRECTION FROM THE STRUCTURAL ENGINEER AND AUTHORITY HAVING JURISDICTION. 8.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST CURRENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. WHERE THE ACTUAL CONDITIONS VARY FROM THAT SHOWN IN THESE DRAWINGS, THEY SHALL BE REPORTED TO THE ARCHITECT AND STRUCTURAL ENGINEER SO THAT PROPER CLARIFICATION OR REVISION MAY BE MADE. THE CONTRACTOR SHALL NOT PROCEED WITH THE AFFECTED WORK UNTIL CLARIFICATION AND/OR DIRECTION HAS BEEN GIVEN. 9.THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHOD OR SEQUENCE OF CONSTRUCTION, UNLESS SPECIFICALLY NOTED OTHERWISE. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BUT NOT LIMITED TO BRACING, SHORING, AND LAY DOWN OF MATERIALS. 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EFFECTS OF TEMPORARY CONSTRUCTION LOADING, INCLUDING LOADING FROM EQUIPMENT SUCH AS SKIP LOADERS, SCISSOR LIFTS, ETC. AND HORIZONTAL WIND AND SEISMIC FORCES IMPOSED DURING THE CONSTRUCTION SCHEDULE, ON ALL PORTIONS OF THE STRUCTURE, WHETHER ELEVATED OR ON-GRADE. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE PATH-OF-TRAVEL FOR MOVING PERMANENT EQUIPMENT TO ITS FINAL LOCATION, INCLUDING THE EFFECTS OF TEMPORARY LOADING AS THE EQUIPMENT IS INSTALLED. THE CONTRACTOR MAY USE THE “DESIGN LOADS” INFORMATION PROVIDED IN NOTE #1 ABOVE WHEN CONSIDERING TEMPORARY CONSTRUCTION LOADING CONDITIONS. 11.OBSERVATION VISITS TO THE SITE BY REPRESENTATIVES OF THE STRUCTURAL ENGINEER SHALL NOT BE DEEMED TO INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES OR OF THE CONSTRUCTION PROCEDURES. OBSERVATION VISITS AND CONSTRUCTION SUPPORT SERVICES ARE PROVIDED BY THE STRUCTURAL ENGINEER OR HIS/HER REPRESENTATIVE SOLELY FOR THE PURPOSE OF ASSISTING THE OWNER IN QUALITY CONTROL AND IN ACHIEVING CONFORMANCE WITH THE CONTRACT DOCUMENTS. THESE SUPPORT SERVICES SHALL NOT BE DEEMED TO PROVIDE A GUARANTEE OF THE CONTRACTOR'S PERFORMANCE AND SHALL NOT BE CONSTRUCTED AS ACCEPTANCE OR SUPERVISION OF CONSTRUCTION. 12.SUBMITTALS: A.SHOP DRAWINGS AND SUBMITTALS, INCLUDING CONCRETE MIX DESIGNS, REQUIRED BY THE SPECIFICATIONS AND/OR THESE DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OR USE. A SCHEDULE FOR THE RELEASE OF SHOP DRAWINGS AND SUBMITTALS SHALL BE PREPARED BY THE CONTRACTOR AND SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO THE FIRST SUBMITTAL. THIS SUBMITTAL SCHEDULE SHALL PROPORTION THE NUMBER OF SHOP DRAWINGS TO BE REVIEWED IN EACH SUBMITTAL TO ALLOW SUFFICIENT TIME AS DEEMED REASONABLE IN THE PROFESSIONAL JUDGMENT OF THE ARCHITECT AND STRUCTURAL ENGINEER TO PERMIT ADEQUATE REVIEW. MHP WILL COORDINATE WITH THE ARCHITECT AND/OR CONTRACTOR TO ENSURE THAT THE SUBMITTAL SCHEDULE PRIORITIZES THE REVIEW IN A MANNER CONSISTENT WITH THE ANTICIPATED CONSTRUCTION SEQUENCE. SHOP DRAWINGS AND SUBMITTALS SHALL REFERENCE THE LATEST REVISION OF EACH STRUCTURAL DESIGN DRAWING USED FROM WHICH TO DETAIL. SHOP DRAWINGS AND/OR SUBMITTALS THAT DO NOT IDENTIFY THE LATEST REVISION OF THE STRUCTURAL DRAWINGS AND/OR DO NOT REFERENCE THE AGENCY APPROVED CONSTRUCTION DOCUMENTS SHALL BE RETURNED FOR THE DETAILER TO UPDATE AND RESUBMIT. PARTIALLY COMPLETE SHOP DRAWINGS AND SHOP DRAWINGS COMPLETED WITHOUT INCORPORATING THE INFORMATION PROVIDED IN RESPONSE TO REQUESTS FOR INFORMATION (RFI/RFC) MAY BE RETURNED (AT MHP'S SOLE DISCRETION) FOR UPDATING IF IT IS DETERMINED THAT SUCH INFORMATION WAS PROVIDED IN A TIMELY MANNER PRIOR TO THE RELEASE OF THE SHOP DRAWING SUBMITTAL. IF A SUBMITTAL MUST BE REVISED, IT SHALL IDENTIFY EACH REVISION AND/OR ADDITION TO EACH SHOP DRAWING BY CLOUDING OR OTHER MEANS. B.SUBMITTALS, INCLUDING SHOP DRAWINGS, DEFERRED APPROVAL ITEMS, AND RFI/RFCS, WILL NOT BE ACCEPTED BY MHP DIRECTLY FROM THE PROJECT SUB-CONTRACTORS. SUBMITTALS WILL BE ACCEPTED FROM THE OWNER'S AUTHORIZED CONTRACT ADMINISTRATOR (I.E. GENERAL CONTRACTOR, CONSTRUCTION MANAGER, OR ARCHITECT) ONLY AFTER THEY HAVE BEEN CONFIRMED TO COMPLY WITH CONTRACT SUBMITTAL REQUIREMENTS AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. THE OWNER'S AUTHORIZED CONTRACT ADMINISTRATOR SHALL COORDINATE AND VERIFY COMPLIANCE WITH THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS REGARDING DISTRIBUTION OF THE SUBMITTALS TO AND THROUGH THE ARCHITECT'S OFFICE. C.SUBMITTALS FOR DEFERRED APPROVAL ITEMS, SUCH AS (BUT NOT LIMITED TO) ELEVATORS AND CURTAIN WALLS, SHALL INCLUDE CALCULATIONS, DETAILED PLANS AND SPECIFICATIONS FOR ALL ELEMENTS OF THE DEFERRED SYSTEM INCLUDING, BUT NOT LIMITED TO, MEMBERS, SUPPORTING BRACKETS OR ATTACHMENTS, AND ANCHORAGE. DEFERRED APPROVAL ITEM SUBMITTALS SHALL BE ISSUED TO THE ARCHITECT AND STRUCTURAL ENGINEER OF RECORD FOR REVIEW AND VERIFICATION THAT THE PROPOSED SYSTEM DOES NOT NEGATIVELY IMPACT NOR SUBSTANTIALLY CHANGE THE STRUCTURAL LOADS AND SUPPORT CONDITIONS FOR WHICH THE BASE STRUCTURE WAS DESIGNED WITH ADEQUATE TIME TO ALLOW ANY REQUIRED CHANGES TO BE MADE BEFORE FORMAL SUBMITTAL TO THE GOVERNING AGENCY. FOLLOWING VERIFICATION BY THE SEOR AND ARCHITECT, THE MANUFACTURER OR CONTRACTOR SHALL SUBMIT THE CALCULATIONS, DETAILED PLANS, AND SPECIFICATIONS, STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE PROJECT STATE, TO THE GOVERNING AGENCY FOR APPROVAL. INSTALLATION OF DEFERRED ITEM ELEMENTS, SUCH AS GUIDE RAILS, MULLIONS, SUPPORTING BRACKETS, AND/OR ITEMS CONTINGENT ON THE DEFERRED SUBMITTAL SHALL NOT BE STARTED UNTIL THE DETAILED PLANS AND SPECIFICATIONS HAVE BEEN APPROVED BY THE GOVERNING AGENCY. D.WHEN THE ALLOWANCE FOR SUBSTITUTION OF A SPECIFIED MATERIAL OR PRODUCT DESIGNATION IS IMPLIED WITHIN THE CONSTRUCTION DOCUMENTS BY THE USE OF THE WORDS “ACCEPTED ALTERNATES”, “ALTERNATIVE PRODUCTS/SUPPLIERS”, ETC. OR “OR APPROVED EQUAL”, A FORMAL SUBSTITUTION REQUEST SHALL BE SUBMITTED BY THE GENERAL CONTRACTOR. THE FORMAL SUBSTITUTION REQUEST SHALL CLEARLY IDENTIFY THE ORIGINAL PRODUCT AND THE REQUESTED SUBSTITUTE PRODUCT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT THE REQUESTED SUBSTITUTION IS “EQUAL” TO, OR BETTER THAN, THE ORIGINAL PRODUCT FOR ALL CONSIDERATIONS SUCH AS, BUT NOT NECESSARILY LIMITED TO, STRENGTH, PERFORMANCE, AND INSTALLATION VARIABLES, INCLUDING SCHEDULE. SUCH VERIFICATION SHALL BE CLEARLY OUTLINED IN THE FORMAL SUBMITTAL AS A TABULAR COMPARISON BETWEEN THE ORIGINAL PRODUCT CRITERIA AND THE REQUESTED SUBSTITUTE'S PRODUCT CRITERIA. APPROVAL OF THE SUBSTITUTION REQUEST SHALL BE OBTAINED FROM THE ARCHITECT, STRUCTURAL ENGINEER OF RECORD AND, IF NECESSARY, THE GOVERNING AGENCY, PRIOR TO FABRICATION OR INSTALLATION OF THE SUBSTITUTED MATERIAL OR PRODUCT. SYMBOL DESCRIPTION PLAN SYMBOLS - BLDG C STEP IN FOOTING PER 8 S4.1SS F1 FOOTING PER FOOTING SCHEDULE APPROXIMATE LOCATION OF SLEEVE FOR PIPES/ CONDUIT ACROSS FOOTING PER PLUMBING, ELECTRICAL OR MECHANICAL PER 4 S4.1 C1 CONCRETE OR STEEL COLUMN STARTING AT THIS LEVEL PER COLUMN SCHEDULE. WHERE NO COLUMN TYPE IS INDICATED, COLUMN CONTINUES FROM LEVEL BELOW. CJ SLAB CONSTRUCTION/ CONTROL JOINT TOP OF FOOTING ELEVATION AT NOTED LOCATION -6"STEP IN SLAB ELEVATION, DIMENSION AS INDICATED ON PLAN OR DETAIL TOF -1'-0" SLV GB1 GRADE BEAM PER GRADE BEAM SCHEDULE W12x25 BEAM SIZE AND SPAN STEEL BEAM (NON-MOMENT-FRAME) MOMENT CONNECTION PER 8 S5.1 AND 16 S5.1 OPENINGS IN FLOOR OR ROOF PER ARCHITECTURAL OR MECHANICAL DRAWINGS PER 6 S4.3 AND 13 S6.1 MECHANICAL UNIT ABOVE FRAMING (SOLID) OR BELOW FRAMING (DASHED) PER MECHANICAL DRAWINGS TOP OF STEEL TOS 21'-0" DIAGONAL BRACING AT THIS LEVEL DIAGONAL BRACING BELOW THIS LEVEL C1 BOTTOM OF FOOTING ELEVATION AT NOTED LOCATION BOF -1'-0" DIMENSION OF MID-SPAN CAMBER(C=1 1/2") [-3"]ELEVATION OF T/O BEAM ABOVE OR BELOW TYPICAL T/O FRAMING ELEVATION [18] NUMBER OF COMPOSITE BEAM SHEAR STUDS EQUALLY SPACED ALONG BEAM SPAN WHEN OTHER THAN REQUIRED PER PLAN NOTES STEEL BEAM (NON-MOMENT-FRAME) MOMENT CONNECTION PER 8 S5.1 AND 16 S5.1 (2)-BOLT ROWS STEEL DRAG BEAM CONNECTION ROOF/FLOOR INFILL OR ADDITION INDICATES DURAFUSE CONNECTION PER CS8.1 THRU CS8.3 SHEAR WALL PANEL, HOLDOWN TYPE, AND MINIMUM LENGTH AT THIS LEVEL PER TYPICAL SHEAR WALL ELEVATION ("A" STAND FOR SUREBOARD SHEATHING FASTENING SCHEDULE SEE DETAIL A ON SHEET CS5.3 A 10' STEEL STUDS: 1.ALL LIGHT GAUGE FRAMING MEMBERS, INCLUDING BUT NOT LIMITED TO, STUDS, TRACKS, BRIDGING, HEADERS AND BRACING OF THE TYPE AND SIZE SHOWN ON THE PLANS AND SPECIFICATIONS SHALL CONFORM TO STEEL STUD MANUFACTURER'S ASSOCIATION (SSMA, ESR-3064P). A.MEMBER DESIGNATION SHALL BE AS FOLLOWS: EXAMPLE: 600S162-54 = 6" STUD WITH 1 5/8" FLANGE, THICKNESS OF 54 MILS (16 GAUGE). B.MATERIAL THICKNESS SHALL BE IN ACCORDANCE WITH THE FOLLOWING: C.STUD AND JOIST SECTIONS SHALL HAVE THE FOLLOWING FLANGE TIP STIFFENERS (STIFFENING LIP LENGTH): 2.ALL 12, 14 AND 16 GAUGE COMPONENTS SHALL BE MADE FROM COLD-FORMED SHEET OR STRIP STEEL CONFORMING TO ASTM A1003 GRADE 50 OR HOT ROLLED STEEL CONFORMING TO ASTM A1011 GRADE 50, AND ALL 18 GAUGE AND LIGHTER COMPONENTS SHALL BE MADE FROM COLD-FORMED SHEET OR STRIP STEEL CONFORMING TO ASTM A1003 GRADE 33. 3.STRUCTURAL STEEL FRAMING COMPONENTS SHALL BE CUT SQUARELY OR AS REQUIRED TO FIT NEATLY AGAINST ABUTTING MEMBERS. MEMBERS SHALL BE HELD FIRMLY IN PLACE UNTIL PROPERLY FASTENED. 4.SPLICES IN AXIAL LOADED (I.E. LOAD BEARING) STUDS SHALL NOT BE PERMITTED. 5.ALL STEEL TRACKS SHALL BE OF SAME GAGE AS STUDS WITH A MINIMUM 1 1/2” FLANGE, UNLESS NOTED OTHERWISE. 6.ALL STEEL STUDS SHALL HAVE A MINIMUM 1 5/8" FLANGE, UNLESS NOTED OTHERWISE. 7.PROVIDE APPROVED COVERINGS ON EACH SIDE OF STUDS AND JOISTS, OR PROVIDE ADEQUATE BRACING OR BLOCKING AT @ 4'-0"OC PER MANUFACTURER'S INSTRUCTIONS. 8.ALL SHEET METAL SCREWS SHALL COMPLY WITH ASTM C 1513-10, ASME B18.6.4-98 (R2005) AND ICC ES AC 118. PENETRATION OF SCREWS THROUGH JOINED MATERIAL SHALL NOT BE LESS THAN THREE EXPOSED THREADS. 9.PROVIDE THE FOLLOWING MINIMUM CONNECTIONS, UNLESS NOTED OTHERWISE ON PLAN OR DETAIL: A.ALL STUD TO STUD OR BULKHEAD STUD TO CEILING TRACK CONNECTION SHALL HAVE A MINIMUM OF FOUR (4) #10 SHEET METAL SCREWS, UNLESS NOTED OTHERWISE. B.ALL DIAGONAL STUD BRACE CONNECTIONS SHALL HAVE A MINIMUM OF FIVE (5) #10 SHEET METAL SCREWS TO EACH STUD, UNLESS NOTED OTHERWISE. C.ALL STUD TO FLOOR TRACK CONNECTIONS SHALL HAVE A MINIMUM OF TWO (2) #10 SHEET METAL SCREWS TO EACH STUD, UNLESS NOTED OTHERWISE. D.RUNNER TRACK TO CONCRETE OR CONCRETE MASONRY SHALL HAVE TWO (2) HILTI X-U (1 1/2" MIN EMBEDMENT) @ 16"OC (ESR-2269), UNLESS NOTED OTHERWISE. E.RUNNER TRACK TO STEEL FRAMING SHALL HAVE 1/8" X2" LONG FILLET WELDS @ 6"OC, UNLESS NOTED OTHERWISE. F.ALL DOUBLE STUDS SHALL BE BACK-TO-BACK AND HAVE TWO (2) ROWS OF #10 SHEET METAL SCREWS @ 12"OC, UNLESS NOTED OTHERWISE. ROWS SHALL BE LOCATED 1 1/4" FROM EACH FLANGE. 10.ALL LIGHT GAGE WELDING SHALL BE DONE BY ELECTRIC ARC PROCESS WITH E70XX ELECTRODES. MATERIAL THICKNESS DESIGNATION MINIMUM THICKNESS GAUGE 33 .0346 20 43 .0451 18 54 .0566 16 68 .0713 14 97 .1017 12 MEMBER DEPTH IN 100TH'S OF AN INCH FLANGE WIDTH IN 100TH'S OF AN INCH MEMBER DESIGNATION (S=STUD OR JOIST, T=TRACK) MATERIAL THICKNESS IN MILS S600 -162 54 STIFFENER TABLE SECTION FLANGE LENGTH LIP LENGTH S125 1 1/4"3/16" S137 1 3/8"3/8" S162 1 5/8"1/2" S200 2"5/8" S250 2 1/2"5/8" POWDER DRIVEN FASTENERS (SHOT PINS): 1.SHOT PINS SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS AND THE APPLICABLE EVALUATION REPORT AND SHALL BE INSTALLED BY PERSONNEL TRAINED TO INSTALL THE TYPE OF SHOT PIN BEING INSTALLED. 2.SHOT PINS SHALL BE USED AT INTERIOR CONDITIONS ONLY AND SHALL BE 0.157”Ø HILTI X-U UNIVERSAL FASTENERS (OR APPROVED EQUAL) CONFORMING TO ICC ESR-2269 UNLESS NOTED OTHERWISE. SPACING OF SHOT PINS IN CONCRETE SHALL BE A MINIMUM OF 4 INCHES ON CENTER AND SHALL HAVE A MINIMUM CONCRETE EDGE DISTANCE OF 3”. SPACING OF SHOT PINS INTO STRUCTURAL STEEL SHALL HAVE A MINIMUM SPACING OF 1 INCH AND A MINIMUM BASE STEEL EDGE DISTANCE OF 1/2”. FOR PROJECTS WITH GOVERNING AGENCY OTHER THAN DSA, THIS NOTE ALSO APPLIES TO SHOTPINS IN SOLID GROUTED MASONRY. 3.SHOT PINS ATTACHING TREATED WOOD SILL PLATES TO CONCRETE INCLUDING AT EXTERIOR WALLS PROTECTED BY AN EXTERIOR WALL ENVELOPE (NON-SHEAR WALL APPLICATIONS) SHALL BE 0.145”Ø HILTI X-CP 72 SILL PLATE FASTENERS MECHANICALLY GALVANIZED PER ASTM B695 TYPE 1, MINIMUM CLASS 55 AND SHALL CONFORM TO ICC ESR-2379, (OR APPROVED EQUAL). SHOT PINS SHALL BE INSTALLED THROUGH A WASHER AND 2X SILL PLATE ONLY AND SHALL HAVE A MINIMUM EDGE DISTANCE IN CONCRETE OF 1 3/4”. CONCRETE SHALL BE A MINIMUM OF 4 1/2” THICK. WHERE DSA OR OSHPD IS THE GOVERNING AGENCY, SHOT PINS MAY NOT BE USED IN CONCRETE CURBS. 4.SHOT PINS IN STEEL SHALL BE DRIVEN TO WHERE THE POINT PENETRATES THROUGH THE BASE STEEL, EXCEPT FOR BASE STEEL GREATER THAN 3/4” THICK, POINT PENETRATION SHALL BE A MINIMUM OF 1/2”. SHOT PINS SHALL NOT BE DRIVEN THROUGH STRUCTURAL STEEL INTO LIGHT GAUGE STEEL MATERIAL. 5.SHOT PINS IN CONCRETE SHALL HAVE A MINIMUM EMBEDMENT OF 1”, UNLESS NOTED ON SECTION OR DETAIL. BUT NOT GREATER THAN THAT SPECIFIED ON PLAN. FOR PROJECTS WITH GOVERNING AGENCY OTHER THAN DSA, THIS NOTE ALSO APPLIES TO SHOTPINS IN SOLID GROUTED MASONRY. 6.SHOTPINS IN CONCRETE MAY SUPPORT A MAXIMUM OF 90# SERVICE LOAD FROM ACOUSTIC TILE CEILING, MINOR DUCTWORK, CONDUIT, ETC.; HOWEVER, WHERE DSA IS THE GOVERNING AGENCY, SHOTPINS MAY NOT BE USED TO SUPPORT SEISMIC LOADS FROM ACOUSTIC TILE CEILING BRACING WIRES. 7.SEE SPECIAL INSPECTIONS AND TESTING NOTES FOR INSPECTION AND TESTING REQUIREMENTS. POST-INSTALLED ANCHORS: 1.POST INSTALLED ANCHOR NOTES IN THIS SECTION SHALL APPLY TO ALL ANCHORS (INCLUDING THREADED ROD OR REINFORCING BARS) INSTALLED INTO HARDENED CONCRETE OR MASONRY EXCEPT FOR POWDER DRIVEN FASTENERS, AS APPLICABLE, SEE POWDER DRIVEN FASTENER GENERAL NOTES FOR MORE INFORMATION. 2.INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S INSTRUCTIONS AND THE APPLICABLE EVALUATION REPORT AND SHALL BE INSTALLED BY PERSONNEL TRAINED TO INSTALL THE TYPE OF POST-INSTALLED ANCHOR BEING INSTALLED. 3.LOCATE EXISTING REINFORCING BY NON-DESTRUCTIVE METHODS PRIOR TO DRILLING. EXISTING REINFORCING SHALL NOT BE CUT OR DAMAGED. 4.CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF F'C = 2500 PSI, BE A MINIMUM OF 21 DAYS OLD AND HAVE A MINIMUM TEMPERATURE OF 50 DEGREES FAHRENHEIT WHEN DRILLING OCCURS. 5.HOLES FOR INSTALLATION OF THE POST-INSTALLED ANCHOR SHALL BE DRILLED USING A DRILL THAT HAS A CARBIDE-TIPPED BIT THAT COMPLIES WITH ANSI B212.15. A REBAR CUTTING DRILL BIT IS NOT ALLOWED. 6.CONTRACTOR SHALL USE APPROPRIATE EQUIPMENT AND METHODS AS REQUIRED TO PROVIDE DRILLED HOLES FOR POST-INSTALLED ANCHORS IN ACCORDANCE WITH APPLICABLE STANDARDS, MANUFACTURER'S RECOMMENDATIONS, AND QUALIFYING (ICC) TEST REPORTS. CARE SHALL BE TAKEN TO PREVENT OVERSIZING, OVALING, AND/OR BLOW-OUT THROUGH THE BACK FACE OF THE DRILLED MEMBER. IF OVERSIZING, OVALING, AND/OR BLOW-OUT OCCURS, THE EMPLOYED EQUIPMENT AND METHODS SHALL BE DISCONTINUED. ADDITIONAL DRILLING SHALL NOT BE RESUMED UNTIL THE SEOR HAS PROVIDED APPROVED REPAIR PROCEDURES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF ALL SUCH REPAIRS. WHEN RESUMING DRILLING, THE CONTRACTOR SHALL MODIFY THE PROCEDURES AS NECESSARY TO PREVENT FURTHER DAMAGE. 7.HOLES SHALL BE CLEANED OF DUST AND DEBRIS, USING A WIRE BRUSH AND COMPRESSED AIR OR MANUFACTURER'S BLOW-OUT BULB (AS PER MANUFACTURER'S RECOMMENDATIONS) AS REQUIRED TO REMOVE PARTICULATE DEBRIS AND TO ACHIEVE A RELATIVELY DUST-FREE SURFACE. 8.OIL, SCALE, AND RUST SHALL BE REMOVED FROM THE POST-INSTALLED ANCHOR AND HOLES SHALL BE DRY, PRIOR TO INSTALLATION. 9.CONCRETE SHALL HAVE ATTAINED THE SPECIFIED COMPRESSIVE STRENGTH NOTED ON THESE DRAWINGS PRIOR TO INSTALLATION OF ANCHORS. 10.POST-INSTALLED EMBEDMENT DEPTHS NOTED ON THE PLANS OR DETAILS ARE NOMINAL (I.E. MEASURED FROM FACE OF CONCRETE OR MASONRY TO EMBEDDED TIP OF ANCHOR/REBAR). FOR CORRESPONDING HOLE DEPTH, REFER TO APPLICABLE EVALUATION REPORT. 11.ANCHORS IN APPROVED ADHESIVE ANCHOR SYSTEMS SHALL HAVE MINIMUM Fy = 36 KSI AND SHALL BE ZINC ELECTROPLATED OR HOT-DIP GALVANIZED AS REQUIRED PER ESR. 12.APPROVED ADHESIVE ANCHOR SYSTEMS AND EVALUATION REPORTS ARE AS FOLLOWS: A.CONCRETE: §HILTI HIT-RE 500 V3 ESR-3814 §HILTI HIT-HY 200 V3 ESR-4868 §DEWALT PURE 110+ESR-3298 §DEWALT AC200+ESR-4027 §SIMPSON SET-3G ESR-4057 B.HORIZONTAL SLAB-ON-GRADE DOWELS: §HILTI HIT-RE 100 ESR-3829 §HILTI HIT-HY 100 ESR-3574 §DEWALT PURE 50+ESR-3576 12.WHERE NOTED ON SPECIFIC DETAILS, INSTALLATION OF ADHESIVE ANCHORS SHALL BE BY PERSONNEL CERTIFIED BY AN APPLICABLE CERTIFICATION PROGRAM PER ACI 318 SECTION 17.8.2.2. CERTIFICATION SHALL INCLUDE WRITTEN AND PERFORMANCE TESTS IN ACCORDANCE WITH ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM. CERTIFICATION DOCUMENTS SHALL BE SUBMITTED TO THE SEOR AND AHJ FOR REVIEW AND ACCEPTANCE PRIOR TO INSTALLATION. 13.ALL EXPANSION ANCHORS SHALL BE INSTALLED WITH THE REQUIRED TORQUE AS NOTED IN THE APPLICABLE EVALUATION REPORT. APPROVED EXPANSION ANCHORS AND EVALUATION REPORTS ARE AS FOLLOWS: A.CONCRETE NOT EXPOSED TO WEATHER: §HILTI KWIK BOLT-TZ2 ANCHORS ESR-4266 §DEWALT POWER-STUD+ SD2 ESR-2502 §SIMPSON STRONG-TIE STRONG-BOLT 2 WEDGE ANCHOR ESR-3037 B.CONCRETE EXPOSED TO WEATHER: §STAINLESS STEEL HILTI KWIK BOLT-TZ2 ANCHORS ESR-4266 §DEWALT POWER-STUD+ SD4 OR SD6 ESR-2502 §STAINLESS STEEL SIMPSON STRONG-TIE STRONG-BOLT 2 WEDGE ANCHOR ESR-3037 14.EXPANSION ANCHORS SHALL BE INSTALLED WITH THE MINIMUM TORQUE USING A CALIBRATED TORQUE WRENCH. EXPANSION ANCHORS MUST ATTAIN THE SPECIFIED TORQUE WITHIN ONE HALF TURN OF THE NUT, EXCEPT 1/4” AND 3/8” DIAMETER EXPANSION ANCHORS MUST ATTAIN SPECIFIED TORQUE WITHIN ONE QUARTER TURN OF THE NUT. 15.ALL SCREW ANCHORS SHALL BE INSTALLED WITH THE REQUIRED TORQUE AS NOTED IN THE APPLICABLE EVALUATION REPORT. APPROVED SCREW ANCHORS AND EVALUATION REPORTS ARE AS FOLLOWS: A.CONCRETE: §HILTI KH-EZ OR KH-EZ P ANCHORS ESR-3027 §DEWALT SCREW-BOLT+ESR-3889 §DEWALT ULTRACON+ESR-3068 §SIMPSON TITEN HD ESR-2713 §ITW RED HEAD TAPCON+ESR-3699 16.SEE SPECIAL INSPECTION AND TESTING NOTES FOR INSPECTION REQUIREMENTS. S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N A INRFOILA A ONS L E N G I KEN N E T H D.O'DEL L U R A LTSRUCT Signed: 11/25/2025 H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 3 H i l t o n A r c a d i a H o t e l R e s t a u r a n t ( d o n o t d e l e t e ) \ 3 _ D r a w i n g s \ D w g s - 0 3 \ 1 9 - 0 2 8 3 - 0 3 _ B l d g C _ S 2 0 0 R F O R R E F E R E N C E O N L Y . d w g P L O T T E D B Y : Je s s e D e l g a d o O N : No v e m b e r 2 5 , 2 0 2 5 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 S200R HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 08.27.25 TI PLAN CHECK (2ND) LA21.522 FOR REFERENCE ONLY LONG BEACH • SAN DIEGO Project: LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 STRUCTU RAL E N GI N SREE 19-0283-03 S No.4101IS G E R OF C TA ST E R EF D P R O TE E I REE N AINRFOILA A ONS L E N G I KE N N E T H D.O'DEL L U R A LTSRUCTPR O G R E S S - NOT F O R P L A N REV I E W 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET SCALE:S200R FOR REFERENCE ONLY A NONE S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N A INRFOILA A ONS L E N G I KEN N E T H D.O'DEL L U R A LTSRUCT Signed: 11/25/2025 UNPUNCHED STEEL TRACK (TOP OR BOTTOM, HEADER OR SILL) PER PLAN (GA EQUAL OR GREATER THAN STUD GA) #10 SMS EA SIDE, EA STUD STUD ENDS TO BEAR ON TRACK WEB NOTE: STUD TO TRACK CONNECTION SCREWS ALTHOUGH REQUIRED, MAY NOT BE SHOWN ON OTHER DETAILS FOR CLARITY. STEEL STUDS PER PLAN OR FRAMING ELEV 1 1 / 2 " MI N SCALE:S600 TYPICAL STEEL STUD TO TRACK CONNECTION 3 NONE UNPUNCHED STEEL TRACK (TOP OR BOTTOM, HEADER OR SILL) PER PLAN (GA EQUAL OR GREATER THAN STUD GA) #10 SMS EA SIDE, EA STUD STEEL STUDS PER PLAN OR FRAMING ELEV STUD ENDS TO BEAR ON TRACK WEB WELD (EA SIDE) PER APPLICABLE DETAIL, TYP ADDL STEEL STUDS AS OCCUR 1 1 / 2 " MI N SCALE:S600 TYPICAL MULTIPLE STEEL STUDS TO TRACK CONNECTION 4 NONE NOTE: STUD TO TRACK CONNECTION SCREWS ALTHOUGH REQUIRED, MAY NOT BE SHOWN ON OTHER DETAILS FOR CLARITY. #10 SMS EA SIDE, TYP TYP STEEL TRACK PER PLAN TYP STEEL TRACK PER PLAN TYP STEEL TRACK PER PLAN #10 SMS @ 24"OC, STUD TO STUD #10 SMS EA SIDE, TYP TYP STEEL TRACK PER PLAN SCALE:S600 TYPICAL STEEL STUDS AT CORNER 5 NONE EQ EQ EQ EQ TYP STEEL STUD PER PLAN OR FRAMING ELEV, TYP3" MAX #10 SMS @ 24"OC, STUD TO STUD, TYP EQ EQ TYP STEEL STUD PER PLAN OR FRAMING ELEV, TYP TYP STEEL TRACK PER PLAN EQ EQ 3" M A X F R O M EN D O F T R A C K WH E R E O C C U R S ANCHOR PER TYPICAL BOTTOM TRACK ANCHORAGE STUD WALL DETAILS, TYP ANCHOR PER TYPICAL BOTTOM TRACK ANCHORAGE STUD WALL DETAILS, TYP 3" M A X F R O M EN D O F T R A C K WH E R E O C C U R S #10 SMS EA SIDE, TYP TYP STEEL TRACK PER PLAN #10 SMS @ 24"OC, STUD TO STUD, TYP TYP STEEL TRACK PER PLAN #10 SMS @ 24"OC, STUD TO STUD, TYP TYP STEEL STUD PER PLAN OR FRAMING ELEV, TYP #10 SMS EA SIDE, TYP TYP STEEL TRACK PER PLAN TYP STEEL TRACK PER PLAN EQ EQ EQ EQ ANCHOR PER TYPICAL BOTTOM TRACK ANCHORAGE STUD WALL DETAILS, TYP EQ EQ EQ EQ ANCHOR PER TYPICAL BOTTOM TRACK ANCHORAGE STUD WALL DETAILS, TYP SCALE:S600 TYPICAL STEEL STUDS AT INTERSECTION 6 NONE TYP STEEL STUD PER PLAN OR FRAMING ELEV, TYP 3" M A X F R O M EN D O F T R A C K WH E R E O C C U R S 3" M A X F R O M EN D O F T R A C K WH E R E O C C U R S SCALE:S600 TYPICAL STEEL TRACK BACKING 8 NONE 1" MIN TYP 600T200-54 (6" x16GA MIN) BACKING (RUN PAST 3 STUDS MIN AND AT LEAST 1 STUD EA SIDE OF CONNECTION POINT), COPE FLANGES AT STUDS (3)-#10 SMS AT EA STUD CONNECTION POINT (SMS, UNO) PER APPLICABLE DETAIL (LOCS VARY PER CONFIG OF ATTACHED ACCESSORIES) - ONLY ONE CONN POINT ALLOWED BTWN EA STUD STEEL STUD PER PLAN OR FRAMING ELEV, TYP NOTE: DO NOT CUT OR NOTCH BACKING EXCEPT AS SHOWN. 6" M I N SCALE:S600 TYPICAL FURRING CONNECTION TO NON-BEARING STEEL STUD WALL 9 NONE PLAN VIEW NOTE: CONNECT FURRING TRACK TO STUD TRACK AT SILLS AND HEADERS, AND STUD TO STUD AT JAMBS W/ #10 SMS @ 24"OC. FINISH PER ARCH FURRING STUD (MIN FLANGE WIDTH = 1 5/8") FINISH PER ARCH EXTERIOR OR INTERIOR NON-BEARING STUD #10 SMS @ 24"OC STEEL STUD BRIDGING PER 7 S600 TYP SCALE:S600 TYPICAL STEEL STUD BLOCKING 10 NONE COPE AS REQD & BEND WEB FLUSH UP WEB 2", TYP EA END STEEL JOIST OR STUD PER PLAN, TYP (2)-#10 SMS EA END, BLK TO JOIST, TYP FULL HT/ DEPTH BLOCKING PER APPLICABLE DETAIL NOTE: WHERE SHOT PIN IS LESS THAN 3" FROM EDGE OF CONCRETE SLAB, OR WHERE STUD TRACK SITS ON A CONCRETE CURB (6" WIDE OR LESS), PROVIDE 3/8"Ø SCREW ANCHOR (2 1/2" EMBED, 1 1/2" MINIMUM EDGE DISTANCE) PER POST-INSTALLED GENERAL NOTES INTO STRUCTURAL CONCRETE IN LIEU OF SHOT PINS (ONE-FOR-ONE SUBSTITUTION). 1.WHERE STUD TRACK SITS ON NON-STRUCTURAL FLOOR MATERIAL SUCH AS TILE, TERRAZZO, ETC., PROVIDE SCREW ANCHORS PER NOTE 1. STEEL STUD TO TRACK CONN PER 4 S600 2" MAX STEEL STUD TO TRACK CONN PER 3 S600 TYP STRUCTURAL FLOOR PER PLAN MULTIPLE STEEL STUD PER PLAN OR FRAMING ELEV STEEL TRACK PER PLAN OR FRAMING ELEV STEEL STUD PER PLAN OR FRAMING ELEV (3)-SHOT PINS CTRD ON TRACK WIDTH & JAMB, UNO PLACE ALL SHOT PINS ON ONE SIDE AT DOOR JAMB CONDITION B TYPICAL AT MULTIPLE STUDS CONDITION A TYPICAL AT SINGLE STUDS & STUDS WITH STEEL BACKING SHOT PINS 8" FROM ENDS & @ 24"OC MAX, TYP EXCEPT @ 10"OC WHERE STEEL STUD BACKING OCCURS (CTR SHOT PINS ON TRACK WIDTH), 3 SHOT PINS MIN PER TRACK, TYP 4" TYP SCALE:S600 TYPICAL BOTTOM TRACK ANCHORAGE AT INTERIOR STEEL STUDS 1 NONE CLIP ANGLE TO MATCH GA OF STUDS W/ (2)-#10 SCREWS TO BRIDGING CHANNEL AND STUDS STEEL STUD PER PLAN OR FRAMING ELEV 1 1/2" HORIZ CHANNEL BRIDGING, GAUGE TO MATCH STEEL STUD GAUGEST E E L S T U D B R I D G I N G @ 4 ' - 0 " O C M A X NOTE: UNLESS NOTED OTHERWISE ON PLAN, STEEL STUD BRIDGING SHALL BE INSTALLED WHERE SHEATHING DOES NOT OCCUR ON BOTH SIDES OF THE STUD FOR FULL HEIGHT OF STUD. WHERE SHEATHING OR FINISH IS DISCONTINUED, BRIDGING IS REQUIRED. PLAN VIEW 1/16 1/2 AT CONTRACTOR'S OPTION, WELD IN LIEU OF SCREWS SCALE:S600 TYPICAL STEEL STUD BRIDGING 7 NONE SCALE:S600 NOT USED 2 NONE SCALE:S600 TYPICAL INTERIOR STEEL STUD WALL FRAMING ELEVATION A NONE 3 S620 3 S600 6 S620 INTERIOR STEEL STUD FRAMING ELEVATION NOTES: 1.SEE NON-BEARING INTERIOR STEEL STUD SCHEDULE ON THIS SHEET FOR MINIMUM REQUIRED STUD DEPTH AND SPACING OF ALL INTERIOR NON-BEARING STEEL STUD WALLS. MATCH STUD DEPTH SHOWN ON ARCHITECTURAL DRAWINGS. 2.ALL STEEL STUDS SHALL BE "C" TYPE STUDS WITH FLANGE STIFFENERS AT OPEN SIDE. 3.WHERE FURRING STUDS OCCUR, SPACING SHALL MATCH FRAMING STUD SPACING. SEE DETAIL 9 / S600 FOR MORE INFORMATION. 4. DENOTES CASEWORK, SHELVING, TOILET ACCESSORIES, GRAB BARS, WALL HUNG LAVATORIES, CABLE TRAYS, EQUIPMENT, ETC., INCLUDING ITEMS INDICATED AS NOT IN CONTRACT (NIC), AND WHERE SPECIFICALLY REFERENCED. SEE ELEVATION FOR SUPPORTING STUD GAUGE AND SPACING. 5.IN NO CASE SHALL STUDS (SINGLE OR MULTIPLE) AT SIDES OF OPENINGS (JAMBS) BE CUT FOR DUCTWORK OR FOR ANY OTHER PURPOSE NOT SPECIFICALLY ADDRESSED ON THESE STRUCTURAL DRAWINGS. 6.SEE GENERAL NOTES SHEET(S) FOR STEEL STUD NOTES, INCLUDING SSMA STEEL STUD IDENTIFICATION TABLE. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL STUD AND BRACING REQUIREMENTS. 7.SEE TYPICAL BOTTOM TRACK ANCHORAGE AT INTERIOR STEEL STUDS DETAIL 1 / S600 FOR TRACK ANCHORAGE AT ALL INTERIOR STEEL STUDS, TYPICAL UNLESS NOTED OTHERWISE. 16GA STUDS @ 12"OC TYP WHERE STEEL BACKING OCCURS TYPICAL STEEL BACKING PER 8 S600 TYP 16 ' - 0 " M A X SE E S C H E D U L E B / S6 0 0 F O R N O N - B E A R I N G W A L L H E I G H T S 4'-6" MAX BRIDGING ABOVE CEILING LINE AND WHEREVER WALL FINISH MATERIAL IS OMITTED, SEE 7 S600 TYP MULTIPLE STUD TOP CONN AS OCCURS TYP STUD TO BOT TRACK DOOR OR WINDOW OR SECTIONS PER PLAN 12'-6" MAX 12'-6" MAX DOOR OR WINDOW DOOR OR WINDOW (2 ) - 1 8 G A ST U D S (2 ) - 1 8 G A ST U D S 4' - 0 " MA X 4'- 0 " MA X CEILING LINE UNDERSIDE OF ROOF OR FLOOR DECK, UNO DUCT 4'-6" MAX12'-6" MAX DOOR OR WINDOW (1 ) - 1 8 G A ST U D (2 ) - 1 8 G A ST U D S (2 ) - 1 8 G A ST U D S 16'-6" MAX DOOR OR WINDOW ST U D S ST U D S 3 S601 HEADER 1 S601 SILL (3 ) - 1 8 G A (3 ) - 1 8 G A (1 ) - 1 8 G A ST U D (1 ) - 1 8 G A ST U D (1 ) - 1 8 G A ST U D 10 S601 10 S601 3 S601 HEADER 1 S601 SILL 4 S601 HEADER 8 S601 SILL 3 S601 HEADER 1 S601 SILL 2 S601 HEADER 1 S601 SILL 2 S601 HEADER 1 S601 SILL 6 S620 NOTES: 1.THIS SCHEDULE IS FOR WALLS NOT USED TO SUPPORT ITEMS REQUIRING BACKING. FRAMING ELEVATION PROVIDES ADDITIONAL REQUIREMENTS. 2.ALTERNATE STUD SIZES MAY BE USED IF THE SECTION PROPERTIES OF THE STUDS USED EXCEED, IN ALL CASES, THE PROPERTIES OF THE SIZES NOTED IN THE SCHEDULE. 362S162-33362S162-33 362S162-33 362S162-33 362S162-33 362S162-33 362S162-33 --- 362S162-43 362S162-33 362S162-33 362S162-33 362S162-33 362S162-33 362S162-33 362S162-33 362S162-3320 FT 18 FT 16 FT 14 FT 12 FT 10 FT 8 FT 24"OC16"OC12"OC MIN STUD SIZE REQUIRED FOR SCHEDULED SPACING (L/120 DEFLECTION CRITERIA) (5 PSF) TYPICAL NON-BEARING INTERIOR STUDS-VERTICAL SPAN SCHEDULE HEIGHT OF WALL (VERTICAL SPAN) 362S162-33 362S162-33 362S162-33 362S162-33 SCALE:S600 NON-BEARING INTERIOR STEEL STUD SCHEDULE B NONE 4 S600 TYP MULTIPLE STUD TO BOTT TRACK 4 S620 9 S620 H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 3 H i l t o n A r c a d i a H o t e l R e s t a u r a n t ( d o n o t d e l e t e ) \ 3 _ D r a w i n g s \ D w g s - 0 3 \ 1 9 - 0 2 8 3 - 0 3 _ B l d g C _ S 6 0 0 T Y P I C A L S T E E L S T U D D E T A I L S . d w g P L O T T E D B Y : Je s s e D e l g a d o O N : No v e m b e r 2 5 , 2 0 2 5 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 S600 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 08.27.25 TI PLAN CHECK (2ND) LA21.522 TYPICAL STEEL STUD DETAILS LONG BEACH • SAN DIEGO Project: LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 STRUCTU RAL E N GI N SREE 19-0283-03 S No.4101IS G E R OF C TA ST E R EF D P R O TE E I REE N AINRFOILA A ONS L E N G I KE N N E T H D.O'DEL L U R A LTSRUCTPR O G R E S S - NOT F O R P L A N REV I E W 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N A INRFOILA A ONS L E N G I KEN N E T H D.O'DEL L U R A LTSRUCT Signed: 11/25/2025 SCALE:S601 NOT USED 9 NONE CEILING JOIST SPAN TYPICAL CEILING JOIST - HORIZONTAL SPAN SCHEDULE MINIMUM JOIST/STUD SIZE REQUIRED FOR SCHEDULED SPACING (L/360 DEFLECTION CRITERIA) (13 PSF) 12"OC 16"OC 24"OC 8 FT 10 FT 12 FT 14 FT 16 FT 18 FT 362S162-33 600S162-43 362S162-33 362S162-33 600S162-43 600S162-43 362S162-33 600S162-43 362S162-33 600S162-43 362S162-43 362S162-33 362S162-43 600S162-43 600S162-43 --- NOTES: 1.SCHEDULE IS FOR CEILINGS SUPPORTING SELF WEIGHT. NOT TO BE USED IN ACCESSIBLE CEILING ATTIC SITUATIONS. 2.SEE ADDITIONAL INFORMATION ON BUILDING PLANS FOR SPECIFIC REQUIREMENTS. 3.ALTERNATE JOIST/STUD SIZES MAY BE USED IF THE SECTION PROPERTIES OF THE STUDS USED EXCEED, IN ALL CASES, THE PROPERTIES OF THE SIZES NOTED IN THE SCHEDULE. 4.SEE DETAIL B ON SHEET S601 FOR LATERAL BRACING/ BLOCKING. ------ SCALE:S601 TYPICAL STEEL STUD CEILING JOIST SCHEDULE A NONE SCALE:S601 TYPICAL JAMB POST BETWEEN 12'-6" MAX WIDE OPENINGS 10 NONE 1/8 1/8 1 1/2" TYP 1 1/2" TYP TOP OF CONC CURB OR SLAB AS OCCURS PL3/8 xWALL THK WIDE - (2)-ANCHORS PER 1 S600 BUILT-UP POST PER PLAN VIEWS PLAN VIEW INTERIOR NON-BEARING STEEL STUD WALL 600T200-97, TYP (3)-14GA STUDS PER A S600 & B S600 #12 SMS @ 12"OC, TYP SCALE:S601 TYPICAL INTERIOR STEEL STUD CEILING JOISTS TO STEEL STUD WALL B NONE SOLID STUD BLOCKING, PER 10 S600 CEILING JOIST SPAN - PROVIDE JOIST SIZE PER SCHEDULE A S601 EQUAL EQUAL CEILING PER ARCH WALL FINISH PER ARCH, TYP (4)-#10 SMS AT EA LAP JOINT #10 SMS EA STUD, TYP WALL STUDS AS OCCUR PER PLAN OR FRAMING ELEV WALL STUDS AS OCCUR PER PLAN OR FRAMING ELEV WALL FINISH PER ARCH, TYP STEEL BRIDGING PER 7 S600 TYP CONT END TRACK (THK TO MATCH CEILING JOIST GA) W/ (3)-#10 SMS TO EA WALL STUD (TRACK MAY BE PLACED OVER (1)-LAYER OF GYPBOARD AT INTERIOR RATED WALLS IF PROVIDED CEILING JOIST SPAN < 15FT) ALTERNATE CONNECTION L2 1/2 x2 1/2 x16GA x(JOIST DEPTH -1") W/ (3)-#10 SMS TO TRACK & TO EA JOIST CONT 362S162-54 @ JOIST W/ (2)-#10 SMS TO EA JOIST, TYP CONT 362S162-43 @ JOIST MIDSPAN W/ (2)-#10 SMS TO EA JOIST & (3)-#10 SMS EA BLOCK 2 1/2" WEB BEND #10 SMS EA STUD, TYP CONT 362S162-43 @ JOIST W/ (2)-#10 SMS TO EA JOIST, TYP CONT L1 1/2 x1 1/2 x18GA W/ #10 SMS AT EA JOIST & EA STUD, TYP SCALE:S601 TYPICAL SILL AT 12'-6" MAX OPENING IN NON-BEARING INTERIOR STEEL STUD WALL 1 NONE A A L1 1/2 x1 1/2 x18GA x0'-3" LONG CLIP ANGLE W/ (2)-#10 SMS EA LEG 1/16 STUD TO STUD 1-12 STEEL STUD PER PLAN OR FRAMING ELEV JAMB PER ELEV AT 11'-6" MAX OPENING, USE 18GA STEEL TRACK- AT 12'-6" MAX OPENING, USE 16GA MIN STEEL TRACK SECTION A-A STEEL STUD PER PLAN OR FRAMING ELEV SCALE:S601 TYPICAL HEADER AT 4'-6" MAX OPENING IN NON-BEARING INTERIOR STEEL STUD WALL 2 NONE A A L3x3x18GA CLIP ANGLE xSTUD WIDTH W/ (4)-#10 SMS EA LEG (IN 2 ROWS AS SHOWN) 16GA MIN STEEL TRACK W/ 2" FLANGES SECTION A-A 1 1/2" TYP 3/4" TYP STEEL STUD PER PLAN OR FRAMING ELEV STEEL STUD PER PLAN OR FRAMING ELEV JAMB PER ELEV NOTE: FOR SILL AT 4'-6" MAXIMUM OPENING IN NON-BEARING INTERIOR STEEL STUD WALL, SEE DETAIL 1 ON THIS SHEET. 18GA MIN STEEL TRACK T&B (2)-6"x18GA MIN STEEL STUDS #10 SMS @ 6"OC EA SIDE 1/16 STUD TO STUD1-12 L1 1/2 x1 1/2 x18GA x0'-3" LONG CLIP ANGLE W/ (2)-#10 SMS EA LEG A A #10 SMS @ 6"OC, TYP SCALE:S601 TYPICAL HEADER AT 12'-6" MAX OPENING IN NON-BEARING INTERIOR STEEL STUD WALL 3 NONE L3x3x18GA CLIP ANGLE xSTUD WIDTH W/ (4)-#10 SMS EA LEG (IN 2 ROWS AS SHOWN) 1 1 / 2 " TY P 3/ 4 " TY P STEEL STUD PER PLAN OR FRAMING ELEV STEEL STUD PER PLAN OR FRAMING ELEV JAMB PER ELEV SECTION A-A NOTE: FOR SILL AT 12'-6" MAXIMUM OPENING IN NON-BEARING INTERIOR STEEL STUD WALL, SEE DETAIL 1 ON THIS SHEET. SCALE:S601 TYPICAL HEADER AT 16'-6" MAX OPENING IN NON-BEARING INTERIOR STEEL STUD WALL 4 NONE L1 1/2 x1 1/2 x18GA x0'-3" LONG CLIP ANGLE W/ (2)-#10 SMS EA LEG (3)-16GA MIN STEEL TRACKS (2)-8"x16GA MIN STEEL STUDS #10 SMS @ 6"OC EA SIDE, TYP #10 SMS @ 6"OC, TYP A A JAMB PER ELEV SECTION A-A 1/16 STUD TO STUD1-12 1 1 / 2 " TY P 3/ 4 " TY P L3x3x18GA CLIP ANGLE xSTUD WIDTH W/ (4)-#10 SMS EA LEG (IN 2 ROWS AS SHOWN) STEEL STUD PER PLAN OR FRAMING ELEV STEEL STUD PER PLAN OR FRAMING ELEV NOTE: FOR SILL AT 16'-6" MAXIMUM OPENING IN NON-BEARING INTERIOR STEEL STUD WALL, SEE DETAIL 8 ON THIS SHEET. SCALE:S601 NOT USED 6 NONE SCALE:S601 TYP SILL AT LARGE OPENING IN NON-BEARING INT STEEL STUD WALL 8 NONE A 1/16 1 1/2 - 6 3" LONG AT ENDS L1 1/2 x1 1/2 x16GA x0'-3" LONG CLIP ANGLE W/ (3)-#12 SMS EA LEG, TYP TOP & BOT 1/16 STUD TO STUD 1-12 16GA MIN STEEL TRACK 16GA MIN STEEL STUD A STEEL STUD PER PLAN OR FRAMING ELEV STEEL STUD PER PLAN OR FRAMING ELEV JAMB PER ELEV SECTION A-A NOTE: THIS DETAIL APPLIES TO THE FOLLOWING: ·16'-6" MAXIMUM OPENING IN NON-BEARING INTERIOR STEEL STUD WALL. SCALE:S601 NOT USED 7 NONE SCALE:S601 NOT USED 5 NONE H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 3 H i l t o n A r c a d i a H o t e l R e s t a u r a n t ( d o n o t d e l e t e ) \ 3 _ D r a w i n g s \ D w g s - 0 3 \ 1 9 - 0 2 8 3 - 0 3 _ B l d g C _ S 6 0 1 T Y P I C A L S T E E L S T U D S E C T I O N S A N D D E T A I L S . d w g P L O T T E D B Y : Je s s e D e l g a d o O N : No v e m b e r 2 5 , 2 0 2 5 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 S601 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 08.27.25 TI PLAN CHECK (2ND) LA21.522 TYPICAL STEEL STUD SECTIONS AND DETAILS LONG BEACH • SAN DIEGO Project: LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 STRUCTU RAL E N GI N SREE 19-0283-03 S No.4101IS G E R OF C TA ST E R EF D P R O TE E I REE N AINRFOILA A ONS L E N G I KE N N E T H D.O'DEL L U R A LTSRUCTPR O G R E S S - NOT F O R P L A N REV I E W 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N A INRFOILA A ONS L E N G I KEN N E T H D.O'DEL L U R A LTSRUCT Signed: 11/25/2025 SCALE:S620 TYPICAL STEEL STUD CEILING SOFFIT TO METAL DECK AND STEEL STUD WALL A NONE SCALE:S620 TYPICAL STEEL STUD SOFFIT HUNG FROM STEEL BEAM 8 NONE SCALE:S620 TYPICAL STEEL STUD SOFFIT HUNG FROM CONCRETE SLAB 1 NONE SCALE:S620 TYPICAL NON-BEARING STUD WALL OR SOFFIT BRACING TO SLAB 2 NONE SCALE:S620 TYPICAL STEEL STUD SOFFIT HUNG FROM STEEL BEAM 7 NONE SCALE:S620 NOT USED 5 NONESCALE:S620 TYPICAL NON-BEARING INTERIOR STEEL STUD WALL OFFSET FROM STEEL BEAM 9 NONE SCALE:S620 SOFFIT AT CONCRETE SLAB 14 NONE 1 S620 AT SINGLE SOFFIT TOP BRACE CONN 7 S620 WALL FINISH PER ARCH, TYP WALL STUDS AS OCCUR PER PLAN OR FRAMING ELEV IF DIAG S P A N E X C E E D S 4 ' - 0 " PROVIDE S T U D B R A C I N G A T M I D S P A N O R @ 4 ' - 0 " O C M A X (12'-0" M A X ) S E E N O T E 1 4" DIAG BRACE @ 4'-0"OC MAX, MATCH THICKNESS OF CEILING JOISTS (18 GA MIN) CONT L1 1/2 x1 1/2 x18GA W/ #10 SMS AT EA JOIST & EA STUD, TYP (4)-#10 SMS AT EA LAP JOINT CONC SLAB PER PLAN BEAM AS OCCURS PER PLAN (4)-#10 SMS AT EA LAP JOINT, TYPSTUD BRACING PER B S601 SIM 1/2" MAX 1/2" MAX SOFFIT STUD, MATCH DEPTH, THK & SPACING OF CEILING JOISTS (MIN 600S162-43) ELEVATION A-A IN-PLANE BRACING FOR TOP OF WALL ATTACHMENT, SEE A S600 CEILING JOIST SPAN PROVIDE JOIST SIZE PER SCHEDULE A S601 14'-0" MAX INTERIOR, 8'-0" MAX SPAN EXTERIOR SO F F I T D E P T H 7'- 0 " M A X SO F F I T DE P T H A-A IN PLANE BRACING 1 1 MIN IN PLANE BRACING SOFFIT STUDS 1 1 CONC SLAB PER PLAN ALTERNATE TOP CONNECTION #10 SMS EA STUD, TYP CONT 362S162-54 @ JOIST W/ (2)-#10 SMS TO EA JOIST, TYPGYPBOARD CEILING PER ARCH EQUALEQUAL STUD BLOCKING PER B S601 SIM 12 " MA X NOTE: 1.IF BRACE WILL EXCEED 12'-0" IN LENGTH TO REACH WALL STUD, ATTACH TO DECK PER 2 S620 TO REDUCE BRACE LENGTH. 2.OMIT BRACE IF CEILING/SOFFIT IS LESS THAN 8'-0" WIDE AND SUPPORTED BY A FULL HEIGHT WALL. STEEL STUDS PER PLAN OR FRAMING ELEV STEEL TRACK 1 GA THICKER THAN STUDS W/ 2" FLANGES, PROVIDE (2)-#10 SMS, EA SIDE TO EA STUD BEAM PER PLAN 1/16 2-16 2/3 STUD WIDTH MIN 1/3 STUD WIDTH MAX OVERHANG SHOTPINS @ 16"OC STEEL STUDS PER PLAN OR FRAMING ELEV PROVIDE 2" x(STUD WIDTH -1/4") x1/4" THK PL WASHER AT EA BOLT 1/2"Ø EXP ACCHOR (3 1/4" EFFECTIVE EMBED) @ 16"OC MAX CONC SLAB PER PLAN STEEL STUDS PER PLAN OR FRAMING ELEV STEEL TRACK 1 GA THICKER THAN STUDS W/ 2" FLANGES, PROVIDE (2)-#10 SMS, EA SIDE 3" MIN 1 1 MIN CONC SLAB PER PLAN L3x3x14GA x1'-3" MIN CENTERED ON (2)-FLUTES 3/8"Ø HILTI KB-TZ2 (1 1/2" EMBED) EA END OF ANGLE 1 1/4" MIN TYP DIAG BRACE PER A S620 1" MIN TYP (4)-#10 SMS 3 0 º M I N 6 0 º M A X STEEL STUDS PER PLAN OR FRAMING ELEV BEAM PER PLAN 1/16 2-16 LESS THAN 2/3 STUD WIDTH STIFF PER 2 S620 @ 12" FROM EA END OF ANGLE & @ 4'-0" OC BETWEEN STEEL TRACK 1 GA THICKER THAN STUDS W/ 2" FLANGES, PROVIDE (2)-#10 SMS, EA SIDE TO EA STUD CONT 3/16" THK EQ LEG ANGLE 1/4" MIN 1/2" MAX OVERHANG 3/16 ANGLE TO STIFF PL, TYP 400S200-43 DIAG IN PLANE STUD BRACING W/ (2)-#10 SMS TO EA STUD 8 S620 LESS THAN 2" CONT TOP TRACK & CONN PER 1 S620 AT INTERIOR WALL BEAM PER PLAN 16GA x3" WIDE PLATE @ 16"OC W/ (2)-#10 SMS, TRACK TO PLATE & (2)-SHOT PINS TO UNDERSIDE OF BEAM FLANGE (1 ON EA SIDE OF WEB) INTERIOR STEEL STUD PER PLAN CEILING PER ARCH 6" ± PE R AR C H (2)-#10 SMS AT EACH STUD, TYP #10 SMS EACH SIDE, TYP 362S137-54 STUDS @ 16"OC, TYP 362S137-54 BRACE @ 48"OC W/ (4)-#10 SMS AT EACH END STEEL BEAM AS OCCURS PER PLAN 12 " M A X PER ARCH - 1'-6" MIN 362T150-54 TRACK, TYP 1 1 CONC SLAB, TYP FOR CONN SEE 1 S620 PE R A R C H - 7'- 0 " M A X FOR CONN SEE 2 S620ALT TURNED BACK BRACE LOC WHERE BRACE CANNOT EXTEND OUTSIDE OF SOFFIT SCALE:S620 TYPICAL NON-BEARING INTERIOR MULTIPLE STEEL STUD TO METAL DECK CONNECTION 3 NONESCALE:S620 TYPICAL NON-BEARING INTERIOR STEEL STUD WALL TO CONCRETE SLAB 6 NONE SCALE:S620 TYPICAL NON-BEARING INTERIOR STEEL STUD WALL TO STEEL BEAM 4 NONE SCALE:S620 EXHAUST HOOD ANCHORAGE 11 3/4" = 1'-0" SCALE:S620 NON-BEARING INTERIOR STEEL STUD WALL BRACING 12 NONE WALL PERPENDICULAR TO DECK CONC DECK PER PLAN AA PLAN VIEW A-A SHOTPIN CONFIGURATION 4" MIN TYP (2)-SHOTPINS STRADDLING MULTI STUD, SEE SECTION A-A TRACK BELOW SHOTPIN, TYP MULTI STUD BELOW MULTIPLE STEEL STUD PER FRAMING ELEV NOTE: FOR BALANCE OF INFO NOT SHOWN, SEE 6 S620 5/ 8 " CL R TY P STEEL STUD PER PLAN OR FRAMING ELEV SHOT PIN ICC ESR-2269 @ 12"OC (1" EMBED) 4" MIN SPACING CONC SLAB PER PLAN (MIN 12" THK) 12 " M A X TY P BRIDGING PER 7 S600 CST/SLP-TRK SLOTTED TRACK BY CEMCO (ICC ESR-2012) (TRACK SHALL BE 1 GUAGE THICKER THAN STUDS) W/ #10 SMS CTRD IN SLOTTED HOLE, TYP AT EA STUD 3" MIN 18GA CST/SLP-TRK SLOTTED TRACK BY CEMCO (ICC ESR-2012) W/ #10 SMS CTRD IN SLOTTED HOLE, TYP AT EA STUD STEEL BEAM PER PLAN SHOTPINS @ 16"OC 12 " M A X TY P STEEL STUD PER PLAN OR FRAMING ELEV STEEL STUD PER PLAN OR FRAMING ELEV (MAX OVERHANG PAST BEAM FLANGE IS 1/3 STUD DEPTH) (2)-ROWS SHOTPINS @ 16"OC STEEL STUDS WHERE OCCURS EDGE OF BEAM FLANGE 2" MIN, WHERE LESS SEE 6 S601 BRIDGING PER 7 S600 5/ 8 " CL R TY P P248 CLIPS , TYP 1' - 0 " TY P 6" MA X P1000 DIAG BRACE UNISTRUT P1843 W/ 1/2"Ø BOLT & SPRING NUT (P1010) INTO P1000 1/2"Ø EXPANSION ANCHOR (2" EMBED) 4 5 ° 1/2"Ø FULLY THREADED A36 HANGER ROD W/ P1000 STIFFENER UNISTRUT P1843 W/ 1/2"Ø BOLT & SPRING NUT (P1010) INTO BRACE DBL NUT STRIKE THREADSMAX HANGER LOAD=250# HANGER BRACKET PER MANUF 1/2"Ø EXPANSION ANCHOR (2" EMBED) 1/2"Ø COUPLER PE R AR C H 6" ± 6' - 0 " M A X 362S162-33 STEEL STUD BRACES @ 4'-0"OC, ALT SIDES (BRACES MAY BE SKEWED SLIGHTLY IN ONE DIRECTION IF BRACE LENGTH < 9'-6") CEILING LINE STEEL STUDS PER PLAN OR FRAMING ELEV TYP STEEL TRACK, MIN THICKNESS TO MATCH STUD GA 1 1 MIN L3x3x16GA x0'-3" W/ (3)-#10 SMS TO BRACE & TO CONT TOP TRACK, TYP AT EA BRACE AT CONTRACTOR'S OPTION: CUT BRACE FLANGES, BEND & CONN TO CONT TOP TRACK W/ (2)-#10 SMS @ EA (IN LINE, PARA TO WALL), TYP OPTIONAL BRACE CONNECTION BOTTOM OF FLOOR OR ROOF DECK NOTE: FOR TOP OF BRACE CONNECTIONS, SEE 2 S620 SCALE:S620 PARTIAL HEIGHT WALL 13 3/4" = 1'-0" 3' - 0 " M A X CONC SLAB ON GRADE SIMPSON RCKW5.5 CLIP & RCKW5.5S STIFF W/ (10)-#12 SMS TO STUD & (2)-1/2"Ø TITEN HD CONC SCREWS (NOM EMB=3 1/4") (PER ICC ESR-2713), TYP AT EA STUD 600S162-54 STEEL STUDS @ 16"OC 600T150-54 STEEL TRACK TOP & BOT W/ #10 SMS TO EA STUD, EA FLANGE 45° M I N TYP NUT ABOVE & BELOW BRACE CONN, TYP STIFFENER PER 11 S620 TYP AT EA HANGER ROD DIAG BRACE PER PLAN VIEW HANGER ROD TOP CONN PER 11 S620 TRANSFORMER PER ELEC, MAX OP WT=370# 4'- 0 " M A X BOTTOM OF SLAB 30 " M A X P1354A W/ 1/2"Ø BOLT & P1010 SPRING NUT, TYP AT BOT OF P1000 DIAG BRACES 1/2"Ø BOLT & P1010 SPRING NUT PER PLAN VIEW, TYP P1000, AT UNIT ANCHORS DOUBLE NUT, TYP PLAN VIEW AT BRACES 1/2"Ø HANGER ROD PER PLAN VIEW, TYP 30" MAX 18" MIN 18 " MI N 6" MA X TY P HANGER ROD, TYP AT EA END OF EA P1000 AS SHOWN (4 RODS TOTAL) BOLT, UNIT TO P1000, TYP AT EA CORNER OF UNIT AS SHOWN (4 RODS TOTAL) P1000 DIAG BRACE, TYP AS SHOWN (4 LIKE BRACES TOTAL)- BRACE TOP CONN PER 11 S620 SCALE:S620 BOTTOM SUPPORTED SUSPENDED TRANSFORMER ANCHORAGE 15 3/4" = 1'-0" SCALE:S620 HOOD ANCHORAGE 10 1/2" = 1'-0" WALL PER ARCH HOOD #1: 12'-6" HOOD #2: 4'-0" HO O D # 1 : 4 ' - 6 " HO O D # 2 : 4 ' - 0 " HANGER ROD W/ STIFFENER TO STRUCTURE, SEE 11 S620 (4 LOCS) EXHAUST HOOD, MAX OP WT HOOD #1 = 900# MAX OP WT HOOD #2 = 500# DIAG BRACE AS SHOWN PER 11 S620 (8 LOCS) H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 3 H i l t o n A r c a d i a H o t e l R e s t a u r a n t ( d o n o t d e l e t e ) \ 3 _ D r a w i n g s \ D w g s - 0 3 \ 1 9 - 0 2 8 3 - 0 3 _ B l d g C _ S 6 2 0 T Y P I C A L S T E E L S T U D C E I L I N G S E C T I O N S A N D D E T A I L S . d w g P L O T T E D B Y : Je s s e D e l g a d o O N : No v e m b e r 2 5 , 2 0 2 5 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 S620 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 08.27.25 TI PLAN CHECK (2ND) LA21.522 TYPICAL STEEL STUD CEILING SECTIONS AND DETAILS LONG BEACH • SAN DIEGO Project: LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 STRUCTU RAL E N GI N SREE 19-0283-03 S No.4101IS G E R OF C TA ST E R EF D P R O TE E I REE N AINRFOILA A ONS L E N G I KE N N E T H D.O'DEL L U R A LTSRUCTPR O G R E S S - NOT F O R P L A N REV I E W 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N A INRFOILA A ONS L E N G I KEN N E T H D.O'DEL L U R A LTSRUCT Signed: 11/25/2025 H: \ 2 0 1 9 \ 1 9 0 2 8 3 \ _ 1 9 - 0 2 8 3 - 0 3 H i l t o n A r c a d i a H o t e l R e s t a u r a n t ( d o n o t d e l e t e ) \ 3 _ D r a w i n g s \ D w g s - 0 3 \ 1 9 - 0 2 8 3 - 0 3 _ B l d g C _ S 7 0 0 R F O R R E F E R E N C E O N L Y . d w g P L O T T E D B Y : Je s s e D e l g a d o O N : No v e m b e r 2 5 , 2 0 2 5 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 S700R HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 08.27.25 TI PLAN CHECK (2ND) LA21.522 FOR REFERENCE ONLY LONG BEACH • SAN DIEGO Project: LONG BEACH OFFICE 3900 Cover Street, Long Beach CA 90808 • 562.985.3200 STRUCTU RAL E N GI N SREE 19-0283-03 S No.4101IS G E R OF C TA ST E R EF D P R O TE E I REE N AINRFOILA A ONS L E N G I KE N N E T H D.O'DEL L U R A LTSRUCTPR O G R E S S - NOT F O R P L A N REV I E W 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET SCALE:S700R FOR REFERENCE ONLY A NONE S No.4101IS G E R OF C TA S T E R EF D P R O TE E I RE E N A INRFOILA A ONS L E N G I KEN N E T H D.O'DEL L U R A LTSRUCT Signed: 11/25/2025 M000 MECHANICAL SYMBOLS, ABBREVIATIONS & GENERAL NOTES expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET CONSTRUCTION PHOTOGRAPHS K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M000.dwg, 11/25/2025 3:08:30 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M001 MECHANICAL TITLE 24 K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M001.dwg, 11/25/2025 3:08:30 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M002 MECHANICAL TITLE 24 K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M002.dwg, 11/25/2025 3:10:14 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M101 MECHANICAL BUILDING C - LEVEL 1 FLOOR PLAN - EAST 5 6 7 7 8 9 10 11 12 13 6.7 7.3 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 5 6 7 7 8 9 10 11 12 13 6.7 7.3 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 DN 1" : 12"DN COLO R A D O P L A C E SLOPE SLOPE +24"~ 30" KITCHEN DISHWASHING UTILITYCABINET. CO2 18"x36" DN UP DN UP +44" +18" +18" J UTILITYCABINET. UTILITYCABINET. 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" STAIR ST-C2 ENTRY VESTIBULE C 148 BOH C 152 STAIR ST-C3 RESTAURANT DINING (THE OVALO) C 161 POOL EQUIP. D 004 FRONT DESK C 146 LOBBY C 149 BAR C 151 BAR LOUNGE C 150 WALKWAY C 153 OUTDOOR LOUNGE D 120 POOL DECK D 123 POOL D 124 FITNESS CENTER D 102 STAIR ST-C4 KITCHEN C 154 SERVICE STATION C 157 W C 155 M C 156 BOARD ROOM C 158 HALLWAY C 160 V.I.P DINING 2 C 162 V.I.P DINING 1 C 163 JAPANESE RESTAURANT DINING C 164 MEETING ROOM C 159 JAPANESE RESTAURANT KITCHEN C 165 JAPANESE RESTAURANT V.I.P. SEATING C 166 SOBA PREP C168 V.I.P. PREP C167 MA T C H L I N E MA T C H L I N E K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M101.dwg, 11/25/2025 3:10:23 PM, mario.gobea SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 5/ 1 2 / 2 0 2 2 3 : 3 5 : 0 4 P M HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 VG PROPERTIES INVESTMENTS, LLC NO.DATE ISSUES & REVISIONS expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. (SOBE 190859.4) 11.21.23 PERMIT SET LA21.522 (BULLETIN 1 - IFC SET) M1.02 MECHANICAL BUILDING C - LEVEL 1 FLOOR PLAN - EAST 06.14.24 BULLETIN 8 07.29.24 BULLETIN 9 5 6 7 7 8 9 10 11 12 13 6.7 7.3 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 5 6 7 7 8 9 10 11 12 13 6.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 DN 1" : 12"DN COLO R A D O P L A C E SLOPE SLOPE UTILITYCABINET. 3"3" J J J J J J J J 4 D 4 4 GFI J J GFI J J D 4 4 J J J J TV TV J J J J J J J J J JJ J J J J JJJJ J J J J J J D TV D D J J J JJJJJJJJ J J J J J J J J J J J J J J J J J J J J J J J J JJ J J DN UP DN UP STAIR ST-C2 ENTRY VESTIBULE C 148 BOH C 152 STAIR ST-C3 RESTAURANT DINING (THE OVALO) C 161 POOL EQUIP. D 004 FRONT DESK C 146 LOBBY C 149 BAR C 151 BAR LOUNGE C 150 WALKWAY C 153 OUTDOOR LOUNGE D 120 POOL DECK D 123 POOL D 124 FITNESS CENTER D 102 STAIR ST-C4 KITCHEN C 154 SERVICE STATION C 157 W C 155 M C 156 BOARD ROOM C 158HALLWAY C 160 V.I.P DINING 2 C 162 V.I.P DINING 1 C 163 FUTURE JAPANESE RESTAURANT C 164 MEETING ROOM C 159 MA T C H L I N E MA T C H L I N E 09/16/2024 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M102 MECHANICAL BUILDING C - LEVEL 1 FLOOR PLAN - EAST UP DN UP KING C.1 C 217 QQ C.1 C 219 SUITE C.1 ACC. TUB C 221 ICE C 244 B.O.H C 223 QQ C.1 (C.F.) C 225 KING C.1 C 227 KING C.4 C 229 KING C.4 C 231 KING C.4 C 233 KING C.4 C 235 QQ C.1 C 237 QQ C.1 C 239 KING C.3 C 241 KING C.3 C 240 KING C.1 C 238 QQ C.1 C 236 KING C.4 C 234 KING C.4 C 232 KING C.1 C 230 KING C.1 C 228QQ C.1 C 226 KING C.2 ACC. R.I.S. C 224 KING C.2 (C.F.) CORRIDOR C 200 IDF C 246 STAIR ST-C2 ELEC. C 247 EL E V . L O B B Y C 2 4 5 6 7 7 8 9 10 11 12 136.7 7.3 C.1 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 6 7 7 8 9 10 11 12 136.7 7.3 C.1 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5MA T C H L I N E K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M102.dwg, 11/25/2025 3:09:27 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M103 MECHANICAL BUILDING C - LEVEL 3 FLOOR PLAN - EAST 6 7 7 8 9 10 11 12 136.7 7.3 C.6 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 A.1 UP DN UP SUITE C.5 BALC. ACC. TUB C 322 SUITE C.5 BALC. C 320 KING C.1 C 317 QQ C.1 C 319 SUITE C.1 (C.F.) C 321 ICE C 344 B.O.H. C 323 QQ C.1 C 325 KING C.1 C 327 KING C.4 C 329 KING C.4 C 331 KING C.4 C 333 KING C.4 C 335 QQ C.1 C 337 QQ C.1 C 339 KING C.3 (C.F.) C 341 KING C.3 C 340 KING C.1 C 338 QQ C.1 C 336 KING C.4 C 334 KING C.4 (C.F.) C 332 KING C.1 C 330KING C.1 C 328 QQ C.1 C 326 KING C.2 C 324 CORRIDOR C 300 IDF C 346 STAIR ST-C2 ELEC. C 347 EL E V . L O B B Y C 3 4 5 K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M103.dwg, 11/25/2025 3:08:56 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M104 MECHANICAL BUILDING C - ROOF LEVEL PLAN - EAST 06.14.24 BULLETIN 8 07.29.24 BULLETIN 9 6 7 7 8 9 10 11 12 136.7 7.3 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 DN ELEV. #2 6 D D 12" D D D D D C H D H C D C D C J J 30 " C L R 30"CL R 42 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 30 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 30 " C L R 42 " C L R 30"CLR DN 6 7 7 8 9 10 11 12 136.7 7.3 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 BAR C 402 PANTRY C 403 STORAGE C 403.1 W C 404 M C 405 JANITOR'S CLOSET C 407 STAIR ST-C2 ELEV. EQMT. C 406 MA T C H L I N E MA T C H L I N E WIC-CU K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M104.dwg, 11/25/2025 3:09:37 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M401 MECHANICAL ENLARGED LEVEL 1 PLANS 12 1311.5 12.5 B C D C.4 13.4 JAPANESE RESTAURANT DINING C 164 JAPANESE RESTAURANT KITCHEN C 165 SOBA PREP C168 JAPANESE RESTAURANT V.I.P. SEATING C 166 V.I.P. PREP C167 SERV C169 12 13 B 13.4 HALLWAY C 160 MEETING ROOM C 159 BOARD ROOM C 158 K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M401.dwg, 11/25/2025 3:09:42 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M402 MECHANICAL ENLARGED ROOF PLANS DN STAIR ST-C2 WIC-CU 13.413.413131212 BB CC K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M402.dwg, 11/25/2025 3:09:56 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M501 MECHANICAL DETAILS K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M501.dwg, 11/25/2025 3:09:06 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M502 MECHANICAL DETAILS K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M502.dwg, 11/25/2025 3:10:18 PM, mario.gobea M601 MECHANICAL SCHEDULES - BLDG C expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M601.dwg, 11/25/2025 3:08:43 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET M701 MECHANICAL AIRSIDE DIAGRAMS K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6M701.dwg, 11/25/2025 3:09:52 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET P000 PLUMBING GENERAL NOTES, SYMBOLS & ABBREVIATIONS 11.26.25 PIPES IN WALLS: PIPING UNDER SLAB: CUTTING AND NOTCHING: BORED HOLES: PLUMBING PIPE MATERIAL: SIZE: SLOPE: ACOUSTICAL TREATMENT: expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET P001 PLUMBING SCHEDULES PLUMBING FIXTURE SPECIFICATION PIPE INSULATION THICKNESS SPACE COOLING SYSTEMS(CHILLED WATER, REFRIGERANT AND BRINE) 0.29 - 0.31 100 250 150 125 200 <=1 INSULATION THICKNESS REQUIRED(INCHES) 2.5 SPACE HEATING, HOT WATER SYSTEMS(STEAM, STEAM CONDENSATE AND HOT WATER) AND SERVICE HEATING SYSTEMS 251-350 ABOVE 350 201-250 141-200 105-140 PER 2016 CALIFORNIA ENERGY CODE TABLE 120.3-A 0.21 - 0.27 7540-60 0.32 - 0.34 0.27 - 0.30 0.25 - 0.29 0.22 - 0.28 NOMINAL PIPE DIAMETER(INCHES) 3.0 4.5 1.5 1.0 0.5 2.5 4.0 5.0 1.5 1.5 0.5 1 - < 1.5 2.5 4.5 5.0 2.0 1.5 1.0 1.5 - < 4 3.0 4.5 5.0 2.0 1.5 1.0 4 - < 8 3.0 4.5 5.0 2.0 1.5 1.0 8 < FLUID TEMPERATURE RANGE (°F) CONDUCTIVITY RANGE (BTU-INCH PER HOUR PER SQ. FT. PER °F) INSULATION MEAN RATING TEMPERATURE (°F) PLUMBING PIPE MATERIAL SCHEDULE SERVICE LOCATION PIPE MATERIAL SLOPE WATER ABOVE GRADE BELOW GRADE ABOVE GRADE BELOW GRADE NATURAL GAS ABOVE GRADE 1/32" PER 1' 1/32" PER 1' 1/4" PER 1' 1/4" PER 1' 1/4" PER 15' 1/4" PER 15' GREASE WASTE AND VENT 1/4" PER 15' BELOW FLOOR (INTERIOR) BELOW GRADE (EXTERIOR) ASTM A53 SCHEDULE 40 GALVANIZED STEEL "BLACK" PIPE AND FITTINGS SHALL CONFORM TO CPC. PIPING INSTALLED UNDERGROUND BENEATH BUILDING SHALL CONFORM TO CPC 1210.1.6. ASTM B88 TYPE "L" HARD DRAWN COPPER WITH WROUGHT COPPER FITTINGS. ASTM B88 TYPE "K" HARD DRAWN COPPER, FACTORY INSULATED, WITH WROUGHT COPPER FITTINGS. ABS SCHEDULE 40 PIPE AND DWV FITTINGS SHALL CONFORM TO ASTM D2321-2000 AND CPC. ASTM A53 SCHEDULE 40 GALVANIZED STEEL "BLACK" PIPE AND FITTINGS SHALL CONFORM TO CPC. ASTM D2513-16a POLYETHYLENE "PE" PIPE. ALL FITTINGS SHALL BE AS PER CPC. GAS WATER HEATER 11.26.25 KITCHEN EQUIPMENT/PLUMBING FIXTURE SCHEDULE expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET P101 PLUMBING FLOOR PLAN - SANITARY, GREASE & VENT PIPING · · · 111.35 38.55 149.9 11.26.25 UP UTILITY CABINET. UTILITYCABINET. COLORADO PLACE UTI LI TYCA B I N E T . 3" 3" J D D D D D D J J J J J J J 4 D44 GFI GFI GFI GFI J J J J J J J GFI J J D44 J J J J J J J J J J J J J TV J TV TV TV J J J J J J J JJ J J J J J JJJJJJJJ J J J J J J J J J J J J J JJ JJ J J J J J J J J JJ J J J J J J J J J J GFI J J GFI J J FP FP W W UTILITIES DN 1" : 12"DN SLOPE SLOPE GM SLPB QQ C.3 ACC. TUB C 101 KING C.1 C 103 QQ C.1 C 105 KING C.1 C 107 KING C.1 C 109 QQ C.3 C 102 KING C.1 C 104 QQ C.1 C 106 KING C.1 C 108 KING C.1 C 110 QQ C.1 C 112 ADMIN C 145 I.T. ROOM C 142 STAIR ST-C2 STAIR ST-C1 ENTRY VESTIBULE C 148 BOH C 152 CORRIDOR C 100 STAIR ST-C3 ELEC. C 113 RESTAURANT DINING (THE OVALO) C 161 POOL EQUIP. D 004 FRONT DESK C 146 LOBBY C 149 EXECUTIVE LOUNGE C 147 BAR C 151 QQ C.1 C 111 LUGG./BIKE STORAGE C 141 BAR LOUNGE C 150 WALKWAY C 153 OUTDOOR LOUNGE D 120 POOL DECK D 123 POOL D 124 RISER ROOM C 115 OFFICE C 143 FITNESS CENTER D 102 STAIR ST-C4 KING C.1 (C.F.) C 114 OFFICE C 144 KITCHEN C 154 SERVICE STATION C 157 W C 155 M C 156 BOARD ROOM C 158 HALLWAY C 160 V.I.P DINING 2 C 162 V.I.P DINING 1 C 163 FUTURE JAPANESE RESTAURANT C 164 MEETING ROOM C 159 1 A B C C.3 C.4 D 0.6 2 3 4 5 6 7 7 8 9 10 11 12 13 6.7 7.3 0.5 2.5 3.5 4.5 5.5 6.5 C.6 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 1.5 1 A B C C.3 C.4 D 0.6 2 3 4 5 6 7 7 8 9 10 11 12 13 6.7 0.5 2.5 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 1.5 DN UP DN UP DN UP (E)FCO (E)FS (E)6"SAN (E)FCO 6"SAN EXISTING DOMESTIC WATER ENTRY. FCO FCO (E)6"SAN 6" S A N FCO 4"SAN (E)6"SAN (E ) 4 " S A N (E)4"SAN(E)4"SAN(E)4"SAN 4"SAN 6"SAN 4"SAN TYPICAL ROOM NOTE: REFER TO PLUMBING ENLARGED PLANS FOR DETAILED ROOM INFORMATION. PIPING BELOW SLAB-ON GRADE NOTE: REFER TO SHELL AND CORE PACKAGE FOR COORDINATION BETWEEN PIPING ABOVE AND BELOW SLAB-ON GRADE. (E)FCO (E)4"SAN 1 1 1 1 1 1 1 DBP-1 4" FS-1 SAMPLE WELL GREASE TRAP SCHIER MODEL GB-1000 4" G W 4"GW 6"SD 6"OFD 6"DN-1 6"OFD 6"DN-1 6"SD 6"SD 6"OFD 6"DN-1 8"SD 8"OFD 8"DN-1 8"SD 8"OFD 8"DN-1 6"SD 6"OFD 6"DN-1 8"SD 8"OFD 8"DN-1 8"SD 8"OFD 8"DN-1 4" S A N FCO FCO 4"SAN6"SAN 6"SAN 6"SAN 6"SAN 6"SAN 6"SAN 6"SAN 6"SAN 4" S A N 3"GW 6"SAN 6"SAN 6"SAN 6" S A N 4"SAN 1 1 1 1 2 1 1 1 1 11 1 1 1 4 " S A N 4"SAN 4"SAN 1 3 1"GAS3/4"GAS 3/4" GAS LINE TO GAS FIRE PIT. PROVIDE GAS REGULATOR, SHUT-OFF VALVE, AND EMERGENCY SHUT-OFF SYSTEM BY E AND I SALES (LACS FIRE PIT/GAS GRILL CONTROL SYSTEM (OR SIMILAR BY ISIMET). NOTES: • ALL FLOOR DRAINS SHALL BE PROVIDED WITH TRAP PRIMERS TO MEET CPC 418.3 AND 1007. • HAMMER ARRESTORS SHALL BE PROVIDED AS STATED ON CPC 609.10. • ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH A 2" VENT LINE ROUTED TO THE ROOF LEVEL. 4"SAN 4"SAN REFER TO BUILDING D FOR CONTINUATION. 476.35 TOP OF GRADE/ 469.60 INVERT ELEVATION 466.15 EXISTING SEWER LINE 4"DN-1 4"SD ALL ROOF DRAINS ARE TIED TO UNDERGROUDN STORM SYSTEM. (TYP.) ALL ROOF DRAINS ARE TIED TO UNDERGROUDN STORM SYSTEM. (TYP.) 3" V 3"V 3"V3"V1 1/2"GAS 1 1 / 2 " G A S 1 1 / 4 " G A S 1 1/4"GAS 1 1/4"GAS 1 1/2"GAS 4 expect a difference 305 South 11th Street San Jose, California 95112-2218 408.282.1500 | 408.297.2995 (f) salasobrien.com SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION DA T E SCALE PROJECT NAME AS SHOWN OWNER NAME 7/29/2024 125 W. HUNTINGTON DR. BUILDING C & D ARCADIA, CA 91006 7/29/2024 4:02:22 PM CP1.1A PLUMBING FIRST FLOOR PLAN HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91006 2019-00859-00 VG PROPERTIES INVESTMENTS, LLS Scale: 3/32" = 1'-0"1 PLUMBING FIRST FLOOR PLAN PLUMBING KEYED NOTESXX 1 2 4" WASTE PIPING DOWN FROM FLOOR ABOVE. 4" WASTE PIPING UP FROM BASEMENT PLAN FROM DUAL PUMP SEWEGE SYSTEM (DP-1). 4" GREASE WASTE PIPING DOWN FROM ROOF LEVEL. DROP AND EXTEND GAS PIPING INSIDE WALL DOWN TO BASEMENT TO SERVE GAS DRYERS. COORDINATE FINAL LOCATION, POINT OF CONNECTION, AND PRESSURE REQUIREMENTS WITH EQUIPMENT. 3 4 NO.DATE ISSUES & REVISIONS 11.21.23 PERMIT SET (BULLETIN 1 - IFC SET) Date 6 bar chanbe future 02.26.24 BULLETIN 5 07.29.24 BULLETIN 9 09/16/2024 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET P102 PLUMBING FLOOR PLAN - DOMESTIC WATER & NATURAL GAS PIPING 11.26.25 UP UTILITYCABINET. UTILITYCABINET. expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET P103 PLUMBING ROOF PLAN - NATURAL GAS PIPING 11.26.25 J DN DN 1 A B C C.3 C.4 D 0.6 2 3 4 5 6 7 7 8 9 10 11 12 136.7 7.3 0.5 2.5 3.5 4.5 5.5 6.5 C.6 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 13.4 13.5 1.5 ST-C2.4 ST-C1.4 C406 C405 C401 C402.1 C403.1 C407 C403.2 STORAGE C 403.1 W C 404 M C 405 DINING C 401 DINING C 401.1 STAIR ST-C1 STAIR ST-C2 ELEV. EQMT. C 406 C401.1 XMA6-2 1 XMA6-1 0 XMA6-1 0 MB6-4 2 XMA6-2 0 BAR KITCHEN JANITOR'S CLOSET HAN D S I N K 3-CO M . B A R S I N K D D D C H D C H C GWH-1 (399 CFH)GWH-3 (399 CFH) GWH-5 (399 CFH) GWH-2 (399 CFH) GWH-4 (399 CFH) DOAS-W (191 CFH) 1 1/4"GAS PROVIDE GAS PRESSURE REGULATOR PRIOR TO CONNECTION TO EQUIPMENT. UNISTRUT (TYP OF 3) DOAS-3 (238 CFH) 3/ 4 " G A S 1 1/4"GAS LOCATION OF EXISTING GAS WATER HEATERS WORK IN THIS AREA IS PER SEPARATE PERMIT expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET P501 PLUMBING DETAILS GAS CONNECTION TO EQUIPMENT GAS PRESSURE REGULATOR INSTALLATION SCALE: NONESCALE: NONE SCALE: NONE SCALE: NONE SCALE: NONE FLOOR DRAIN WITH TRAP SEAL PROTECTION INTERIOR WALL PENETRATION INTERIOR FLOOR PENETRATION WALL CLEANOUT DETAIL SHIELD FOR INSULATED PIPING DRAIN DISCHARGE PER CPC 704.3 NEPTUNEHPTURBINE SCALE: NONE DOMESTIC WATER SUB-METER8 SCALE: NONE FLOOR CLEANOUT10 SCALE: NONE QUICK DISCONNECT DETAIL FLOOR SINK 11.26.25 expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET P601 PLUMBING ISOMETRICS GAS PIPING NOTES 11.26.25 expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET P602 PLUMBING ISOMETRICS GAS PIPING NOTES 11.26.25 expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET E000 ELECTRICAL SYMBOLS, ABBREVIATIONS & GENERAL NOTES ” CONSTRUCTION PHOTOGRAPHS K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6E000.dwg, 11/25/2025 3:10:00 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET E001 ELECTRICAL SPECIFICATIONS ” K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6E001.dwg, 11/25/2025 3:09:25 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET E002 ELECTRICAL TITLE 24 K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6E002.dwg, 11/25/2025 3:09:42 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET E101 ELECTRICAL BUILDING C - LEVEL 1 POWER PLAN - EAST 4 5 6 7 7 8 9 10 11 12 13 6.7 7.3 5.5 6.5 C.6 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 4 5 6 7 7 8 9 10 11 12 13 6.7 7.3 5.5 6.5 C.6 C.1 A.7 7.5 8.5 9.5 10.5 11.5 12.5 A B C D C.3 C.4 13.4 13.5 W W FP FP DN 1" : 12"DN COLO R A D O P L A C E SLOPE SLOPE +24"~ 30" KITCHEN DISHWASHING UTILITYCABINET. CO2 18"x36" DN UP DN UP +18" +44" +18" +18" J UTILITYCABINET. UTILITYCABINET. 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" ADMIN C 145 I.T. ROOM C 142 STAIR ST-C2 ENTRY VESTIBULE C 148 BOH C 152 STAIR ST-C3 ELEC. C 113 RESTAURANT DINING (THE OVALO) C 161 POOL EQUIP. D 004 FRONT DESK C 146 LOBBY C 149 EXECUTIVE LOUNGE C 147 BAR C 151 QQ C.1 C 111 LUGG./BIKE STORAGE C 141 BAR LOUNGE C 150 WALKWAY C 153 OUTDOOR LOUNGE D 120 POOL DECK D 123 POOL D 124 RISER ROOM C 115 OFFICE C 143 FITNESS CENTER D 102 STAIR ST-C4 KING C.1 (C.F.) C 114 OFFICE C 144 KITCHEN C 154 SERVICE STATION C 157 W C 155 M C 156 BOARD ROOM C 158 HALLWAY C 160 V.I.P DINING 2 C 162 V.I.P DINING 1 C 163 JAPANESE RESTAURANT DINING C 164 MEETING ROOM C 159 JAPANESE RESTAURANT KITCHEN C 165 JAPANESE RESTAURANT V.I.P. SEATING C 166 SOBA PREP C168 V.I.P. PREP C167 MA T C H L I N E MA T C H L I N E K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6E101.dwg, 11/25/2025 3:09:07 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET E401 ELECTRICAL ENLARGED PLANS ALL EQUIPMENT TO BE LISTED FOR THE PURPOSE, LOCATION AND INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. ALL EQUIPMENT NOT LISTED AS AN ASSEMBLY WILL REQUIRE A 3RD PARTY FIELD EVALUATION BY A COMPANY APPROVE BY THE AHJ. 12 13 11.5 12.5 B C D C.4 13.4 J UTILITYCABINET. UTILITY CABINET. 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" JAPANESE RESTAURANT DINING C 164 JAPANESE RESTAURANT KITCHEN C 165 JAPANESE RESTAURANT V.I.P. SEATING C 166 SOBA PREP C168 V.I.P. PREP C167 SERV C169 11 13 14 15 1612 21 22 23 24 24 19 18 6 6 5 7 1212 18 7 1 2 3 32 18 25 30 7 4 33 18 10 12 7 29 282828 5 9 9 8 8 17 35 34 35 31 3631 7 DN WIC-CU HALLWAY C 160 1212 1313 BB CC C.3C.3 K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6E401.dwg, 11/25/2025 3:10:38 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET EL401 ELECTRICAL LIGHTING ENLARGED PLAN ALL EQUIPMENT TO BE LISTED FOR THE PURPOSE, LOCATION AND INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. ALL EQUIPMENT NOT LISTED AS AN ASSEMBLY WILL REQUIRE A 3RD PARTY FIELD EVALUATION BY A COMPANY APPROVE BY THE AHJ. 12 1311.5 12.5 B C D C.4 13.4 JAPANESE RESTAURANT DINING C 164 JAPANESE RESTAURANT KITCHEN C 165 SOBA PREP C168 JAPANESE RESTAURANT V.I.P. SEATING C 166 V.I.P. PREP C167 SERV C169 MTS12 MTS12 MTS12 MTS12 DAC DAC DAC DAC DAC DAC DAC DAC DAC DAC DACDAC DAC DAC MTS12 DAC DAC K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6EL401.dwg, 11/25/2025 3:10:09 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET EL402 ELECTRICAL EMERGENCY LIGHTING PHOTOMETRICS Luminaire Schedule Symbol Qty Label Arrangement Description 2 CE Single Cooper Metalux - 24CZ2-40-UNV-L835-CD1-U 5 LF Single Vakker Lighting - ledbulb_60w_e26 18 RR Single CSL - WS-AIC-1-15S1; WS-AIC-1-2790-XSTXX-STXX - 50 4 RT Single Integer - RGY3-16L-27K-ID-40 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min C160_Floor Illuminance Fc 14.86 17.2 12.7 1.17 1.35 C164, C166, C167_Floor Illuminance Fc 13.77 69.3 2.2 6.26 31.50 C165_Floor Illuminance Fc 10.29 21.8 1.0 10.29 21.80 C169_Floor Illuminance Fc 14.18 14.2 14.1 1.01 1.01 12 1311.5 12.5 B C D C.4 13.4 JAPANESE RESTAURANT DINING C 164 JAPANESE RESTAURANT KITCHEN C 165 SOBA PREP C168 JAPANESE RESTAURANT V.I.P. SEATING C 166 V.I.P. PREP C167 SERV C169 15.0 13.0 16.9 14.6 14.9 12.7 17.2 14.9 15.3 13.0 16.7 14.5 15.7 13.6 19.1 16.3 12.2 18.6 22.2 22.8 21.1 19.0 18.5 10.2 5.0 10.6 17.8 13.3 7.7 14.2 12.5 10.2 14.4 18.5 22.3 19.5 13.1 13.7 8.2 4.7 8.3 13.1 9.3 4.4 6.7 7.1 6.6 7.8 12.0 21.6 21.0 4.8 7.3 8.0 7.3 7.0 6.0 4.0 3.6 4.8 5.9 6.3 6.1 10.9 21.9 21.9 5.1 15.4 29.2 30.1 22.5 7.4 3.1 3.7 4.9 6.1 6.5 6.3 10.9 22.4 22.3 7.6 31.3 64.8 66.8 48.6 12.9 3.7 3.7 4.9 6.0 6.5 6.2 10.9 22.0 22.0 7.6 32.3 67.3 69.3 50.4 13.3 3.5 3.6 4.7 5.7 6.1 6.0 10.8 22.4 22.3 3.5 4.5 5.5 5.8 5.7 10.6 22.1 22.1 3.5 4.4 5.4 5.8 5.8 10.5 22.1 22.1 3.4 4.4 5.4 5.9 5.7 10.4 21.4 21.4 3.2 4.1 5.0 5.5 5.4 8.6 17.0 16.9 3.0 3.7 4.1 4.4 4.2 5.2 8.1 7.7 2.6 4.1 12.7 35.9 49.2 2.2 3.6 12.9 37.2 51.3 3.9 5.7 8.5 11.7 12.9 11.0 7.5 4.6 6.9 11.0 16.3 18.7 15.3 9.0 5.1 7.6 12.5 18.8 21.8 18.2 5.3 7.8 12.2 17.5 19.9 17.1 5.3 7.8 11.8 16.5 18.5 16.2 5.2 7.8 12.4 18.1 20.6 16.9 8.3 4.5 2.6 1.5 1.0 4.9 7.5 12.3 18.6 21.2 16.9 9.6 4.9 2.7 1.6 1.1 4.3 6.6 10.3 15.2 17.2 13.9 8.9 4.4 2.5 1.5 1.0 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 CE MH: 9 CE MH: 9 RT MH: 9 RR MH: 9 RR MH: 9 LF MH: 9 LF MH: 9 LF MH: 9 LF MH: 9 LF MH: 9 RT MH: 9 RR MH: 9 RR MH: 9 RR MH: 9 RT MH: 9 RT MH: 9 J 2 TC 1LCG 5M TC TC TC TC RR RR RR RR 12H 12H 12H 12H 12 5M 5M MTS12 DAC DAC TC TC RR SH 12H 12 TB SH TYPE , (TYP) D7D7 12G MTS12 DAC 3DEF ;3GH TC TC TC TC RR RR RR RR 12H 12H 12H 12H 1F LJ J2 TC TC TC TC TC TC SH SH SH SH SH SH 12G 12G 12G TB TB TB 3E 3E 3E D7 D7 D7 D7 D7 D7 MTS12 DAC DAC 3DEF J 2 J 3GH N 12 TC RR SH SH SH SH SH SH 1,3 1LCG 71LCG 12G 12H 1F 1HCLB LJ 1N D7 D7 D7 D7 D7 D7 DAC DAC DAC I RR RR RR RR 12I 12I 12I 12I DAC DAC 14.2 14.2 14.2 14.1 J JKLM 1HCLB TC RT RT RT RT LS LB LS LB 12K 12K 12K 12K 12J 12J 1J 1J 1J 1L 1L 1L 1L MTS12 DAC DAC DAC 1 RR 12 RR 1 RR 1 RR 12 12 LJ 12 RS 1 DAC MTS12 DAC JJ 1  DAC FC 166 1J K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6EL402.dwg, 11/25/2025 3:08:46 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET EL403 ELECTRICAL LIGHTING CONTROL AND DIMMING SYSTEM PLAN ABC WST $3D WST $5D RSP RSP BOCA OCS12 CAT WST $3D WST $5D OCS12 CAT RSP BOCA RSP RSPBOCA WST $3D WST $3D ESP ESP WST $3D ESP RSP OCS12CAT WST $3D HI WST $3D RSP RSP OCS12CAT RSP BOCA RSP WACGS308P-100NAS WAH-C-POE 12 1311.5 12.5 B C D C.4 13.4 JAPANESE RESTAURANT DINING C 164 JAPANESE RESTAURANT KITCHEN C 165 SOBA PREP C168 JAPANESE RESTAURANT V.I.P. SEATING C 166 V.I.P. PREP C167 SERV C169 MODELNUMBER ZONE ESP RSP OCS12CAT RSP Symbol Model Number Description WAC2-PoE Controls Up To 200 WaveLinx Devices, Supports Up To 16 Areas Drag and Drop Programming of Lighting Zones Via WaveLinx Mobile App 120V Receptacle Required Within 3 Feet of the WAC RSP-C-010-Z1 Relay Switchpack, 0-10V Dimming, 20A Load 120/277V WAC BF-SDS10V-AST Takes a 0-10V dimming signal and a fixed line voltage input and converts it to a phase-adaptive dimmed output OCS-P-12 PIR and photocell that automatically control lights via CAT communication to compatible dimming and switching devices. 1200sqft GS308P-100NAS Unmanaged Network Switch, 4 Ports to Power and Communicate with WAC-PoEsGS308P-100NAS WST-C-3D CAT Wallstation, 2 Large Buttons, Raise/Lower 120/277V Required, Custom Engraved Buttons Available RSP BOCA OCS12CAT WST-C-5D CAT Wallstation, 4 Buttons, Raise/Lower 120/277V Required, Custom Engraved Buttons Available WST $3D WST $5D WAH-C-POE WAH-C-POE-ID IP-to-CAT bridge connecting CAT devices to the WaveLinx Area Controller. ESP-C-010-Z1 Emergency Relay Switchpack, 0-10V Dimming, 20A Load 120/277VESP K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6EL403.dwg, 11/25/2025 3:09:17 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET E501 ELECTRICAL DETAILS K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6E501.dwg, 11/25/2025 3:08:56 PM, mario.gobea expect a difference 305 South 11th Street San Jose, California 95112-2218 877.725.2755 | 877.925.1477 (f) WWW.SALASOBRIEN.COM National Strength. Local Action. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 OVALO KIZUNA LLC JAPANESE RESTAURANT NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK (SOBE 190859.6) 08.27.25 TI PLAN CHECK (2ND) 10.06.25 TI PLAN CHECK (3RD) 11.26.25 TI PERMIT SET E601 ELECTRICAL SCHEDULES & SINGLE LINE DIAGRAM ALL EQUIPMENT TO BE LISTED FOR THE PURPOSE, LOCATION AND INSTALLED PER THE MANUFACTURER'S INSTRUCTIONS. ALL EQUIPMENT NOT LISTED AS AN ASSEMBLY WILL REQUIRE A 3RD PARTY FIELD EVALUATION BY A COMPANY APPROVE BY THE AHJ. K:\drawings\Pacific Design Group\190859.6 Hilton Hotel at Huntington Center Arcadia Japanese Restaurant\190859.6E601.dwg, 11/25/2025 3:09:17 PM, mario.gobea 3' - 2 " 11 13 14 15 1612 21 22 23 24 24 19 18 6 6 77 7 1212 18 17 4' - 6 " 7 2 32 18 7 4 33 20 26 18 10 1'-0"11'-6" 12 8 8 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" 3 28 28 28 5 5 9 9 34 35 35 31 3137 1 27 30 25 30 " 30" 19"MIN. 19 " M I N . 29 3' - 8 1 / 2 " CL CL SERV SOBA PREP JAPANESE RESTAURANT KITCHEN JAPANESE RESTAURANT V.I.P. SEATING V.I.P. PREP JAPANESE RESTAURANT DINING 36 38 SCALE 1/2"=1'-0"1EQUIPMENT PLAN EQUIPMENT PLAN K100 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 09.18.25 3rd HEALTH PLAN CHECK INTERIOR FULL-HEIGHT DRY WALL FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T SCALE NTS 1 EQUIPMENT SCHEDULE EQUIPMENT SCHEDULE K110 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 09.18.25 3rd HEALTH PLAN CHECK SCALE NTS 9FINISH SCHEDULE FLOOR BASE WALL CEILINGROOM NAME SEALED CONCRETE GALVINIZED METAL SHEET VINYL / VCT TILES SMOOTH FINISH PORCELAIN TILES FLOOR 6"X6" QUARRY TILES CARPET OR WOOD 6"H QUARRY TILES 4" VINYL/RUBBER 6"H WOOD BASE; PAINTED 6"H GALVINIZED METAL SMOOTH FINISH 3/8" RADIUS COVED BASE 6"H CERAMIC TILES (WHITE COLOR; TOPSET) 6"H CERAMIC / PORCELAIN TILES PAINTDRYWALL WALL TILES (FULL HEIGHT) GALVANIZED METAL (FULL HEIGHT) SEMI-GLOSS ENAMEL WALL CEILING DRYWALL PAINT GALVINIZED METAL OPEN SEMI-GLOSS ENAMEL LIGHT COLOR, SMOOTH, NON-ABSORBENT, EASILY CLEANABLE 2'X2' OR 2'X4' WASHABLE T-BAR CEILING VINYL TILES 2'X2' OR 2'X4' T-BAR CEILING TILESFRP ON WATER RESISTIVE DRYWALL F1 F2 F3 F4 F5 F6 F7 F8 EPOXY (TROWELED)MINIMUM OF 4-FOOT HIGH FRP ABOVE THE COVE BASE.LIGHT COLOR, SMOOTH, NON-ABSORBENT, EASILY CLEANABLE STAINLESS STEEL FLASHING (FULL HEIGHT) (FULL HEIGHT) VINYL WALL COVERING 4" H EPOXY CONTINUE FROM FLOOR B1 B2 B3 B4 B5 B6 B7 B8 B9 W1 W2 W3 W4 W5 W6 W7 W8 W9 W10 C1 C2 C3 C4 C5 C6 C7 C8 FINISH SCHEDULE NOTES 1)WALLS AND CEILINGS IN ALL AREAS EXCEPT OFFICE, DINING AREA SHALL BE DURABLE, SMOOTH, NONABSORBENT, AND EASILY WASHABLE WITH A LIGHT COLORED (LIGHT COLORED IS DEFINED AS HAVING A LIGHT REFLECTANCE VALUE OF 70% OR GREATER) FINISH. 2)ALL COUNTER SURFACES INCLUDING UNDERSIDE SHALL BE DURABLE, SMOOTH, NONABSORBENT, EASILY WASHABLE FINISH (MAY REQUIRE STAINLESS STEEL OR HIGH PRESSURE LAMINATE). 3)TILES IN RESTROOMS, SERVICE AREA AND KITCHEN SHALL BE DURABLE, SMOOTH, NONABSORBENT, EASILY WASHABLE FINISH. 4)FLOORING UNDER EQUIPMENT AND AT THE BASE COVES SHALL BE COMPLETELY SMOOTH. FLOOR SURFACES WHICH CONTAIN SLIP-RESISTANT AGENTS SHALL BE RESTRICTED TO TRAFFIC AREAS ONLY. 5)ALL EQUIPMENT SHALL BE EITHER EASILY MOVABLE (IE., ON CASTERS), ON MIN. 6 INCH ROUNDED METAL LEGS, OR SEALED TO MIN. 4 INCH SOLID MASONRY ISLAND WITH MIN. THREE-EIGHTHS INCH COVED RADIUS. 6)CONCRETE FLOOR MUST USE TOP-SET TYPE CERAMIC COVED BASE. 7)WATER RESISTANT WALLS (IE. FRP, STAINLESS STEEL, TILES) ARE REQUIRED BEHIND ALL SINKS AND DISHWASHERS. MATERIAL TO BE MIN. 4 FT. HIGH FOR LA COUNTY, MIN. 8 FT. HIGH FOR OTHER COUNTIES. ALL RESTROOM WALLS TO HAVE MOISTURE RESISTANT GYPSUM BOARD BACKING. 8)A MIN. 50-FOOT CANDLES OF LIGHT MEASURED 30" A.F.F. IN PREP AREAS; A MIN. 20-FOOT CANDLES OF LIGHT IN SAKE BAR, HANDWASHING AREAS, UTENSIL WASHING AREA, & RESTROOMS; A MIN. 10-FOOT CANDLES OF LIGHT IN STORAGE, JANITORIAL AREA & WALK-IN COOLER. CEILING PANEL:THE FOLLOWING CEILING PANELS ARE U.S.G #3270 VINYL ROCK OR NATIONAL GYPSUM GOLD BOND, GRIDSTONE GYPSUM CEILING PANELS. TILES: TOPSET (SLIM-FOOT) CERAMIC COVED BASE: CONCRETE SEALER: DRYWALL PAINT: DALTILE OR EQUIVALENT. B&W TILE CO. #S-3619TN MONOCHEM AQUASEAL W20 A LKYD SEMI-GLOSS ENAMEL WHITE BASE NO. 3900 INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH CBC 803.1, TABLE 803.13 AND TABLE 803.13 INTERIOR FLOOR FINISHES SHALL COMPLY WITH SECTION 804 FLOOR COVERING:THE FOLLOWING ARE APPROVED. SERVICE SOBA PREP V.I.P.PREP KITCHEN UNDER HOOD COOKING AREA WIC F2 F8 F2 F8 F2 F8 F1 F8 B2 B8 B9 B2 B8 B9 B2 B8 B9 B1 B8 B9 C3 C7 C1 C4 C7 C8 C1 C4 C7 C8 C1 C4 C7 C8W1W2 W4 W9 W3 W9 W8 W9F1F8B2B8B9 F1 F8 C5 C7W7W9B1B8B9 W4 W9 W9 W10 FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 8" 8'-10" 5' - 1 0 " 3' - 0 " 9' - 5 " 9'-1" 9' - 5 " 3' - 2 " 3' - 6 " 2'-0"4'-0" 2'-8"7'-10" 2' - 1 " 1' - 9 " 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" 8' - 1 0 " 4'-0" 6' - 1 0 " 1' - 9 " +48" +20" +20" +48" +20" +20" +20" +48" +20"+20" +20"+20" J 3'-0" 3' - 9 " +20" +20" CL CL SERV SOBA PREP JAPANESE RESTAURANT KITCHEN JAPANESE RESTAURANT V.I.P. SEATING V.I.P. PREP JAPANESE RESTAURANT DINING SCALE 1/2"=1'-0"1EQUIPMENT PLAN - ELEC. OUTLETS EQUIPMENT PLAN- ELEC. OUTLETS 3/ 1 2 / 2 0 2 5 2 : 4 6 : 1 7 P M K120 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 09.18.25 3rd HEALTH PLAN CHECK FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 2'-6" 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" +20" +20"+20"+20"+60"+20" 4" CL CL SERV SOBA PREP JAPANESE RESTAURANT KITCHEN JAPANESE RESTAURANT V.I.P. SEATING V.I.P. PREP JAPANESE RESTAURANT DINING 4'-10"1'-4"3'-0"6'-1" SCALE 1/2"=1'-0"1EQUIPMENT PLAN - GAS EQUIPMENT PLAN- GAS 3/ 1 2 / 2 0 2 5 2 : 4 6 : 1 7 P M K130 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 09.18.25 3rd HEALTH PLAN CHECK FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 1'-1" 3'-2"1'-10"1'-10"6'-0" 6' - 1 " 6'-4" 8' - 7 " 8'-9" 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" CL CL SERV SOBA PREP JAPANESE RESTAURANT KITCHEN JAPANESE RESTAURANT V.I.P. SEATING V.I.P. PREP JAPANESE RESTAURANT DINING SCALE 1/2"=1'-0"1EQUIPMENT PLAN - WATER SUPPLY EQUIPMENT PLAN- WATER SUPPLY 3/ 1 2 / 2 0 2 5 2 : 4 6 : 1 7 P M K140 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 09.18.25 3rd HEALTH PLAN CHECK FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 6'-11"5'-7" 3' - 2 " 1' - 0 " 6'-11" 1' - 1 " 6'-5" 7' - 5 " 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" CL CL SERV SOBA PREP JAPANESE RESTAURANT KITCHEN JAPANESE RESTAURANT V.I.P. SEATING V.I.P. PREP JAPANESE RESTAURANT DINING SCALE 1/2"=1'-0"1EQUIPMENT PLAN - WATER WASTE EQUIPMENT PLAN- WATER WASTE 3/ 1 2 / 2 0 2 5 2 : 4 6 : 1 7 P M K150 NO. SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 09.18.25 3rd HEALTH PLAN CHECK FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 14 " x 4 8 " 14 " x 4 8 " 14"x36"14"x36"14"x36" CL CL SERV SOBA PREP JAPANESE RESTAURANT KITCHEN JAPANESE RESTAURANT V.I.P. SEATING V.I.P. PREP JAPANESE RESTAURANT DINING SCALE 1/2"=1'-0"1INDEX PLAN INDEX PLAN 11 K1.61 10 K1.61 3 K1.61 6 K1.61 12 K1.61 9 K1.61 1 K1.61 2 K1.61 4 K1.61 3/ 1 2 / 2 0 2 5 2 : 4 6 : 1 7 P M K160 8 K1.61 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 09.18.25 3rd HEALTH PLAN CHECK FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 1' - 6 " 3' - 0 " 7'-0"7"7" 4" 7' - 0 " 1' - 1 1 " 3' - 0 " 3' - 5 " 34 " H . F O R AC C . C O U N T E R 1' - 1 1 " 3' - 0 " SCALE 3/8"=1'-0"1 SCALE 3/8"=1'-0"2 SCALE 3/8"=1'-0"3 SCALE 3/8"=1'-0"4SCALE 3/8"=1'-0"8 SCALE 3/8"=1'-0"6 SCALE 3/8"=1'-0"9 SCALE 3/8"=1'-0"10 SCALE 3/8"=1'-0"11 SCALE 3/8"=1'-0"12 ELEVATION ELEVATION ELEVATION ELEVATIONELEVATION ELEVATION ELEVATION ELEVATION ELEVATION 7' - 0 " 3' - 0 " 3' - 0 " 34 " H . F O R AC C . C O U N T E R 3' - 5 " 7' - 0 " 3' - 5 " 34 " H . F O R AC C . C O U N T E R 1' - 6 " 3' - 4 " 7'-0"6" 5' - 6 " 4' - 8 " 11"1'-7" 2'-6" 1'-7"11" 2'-6" TYPE I HOOD #1 TYPE I HOOD #2 ELEVATIONS 3/ 1 2 / 2 0 2 5 2 : 4 6 : 1 7 P M K161 SHEET NUMBER ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE ORIGINAL AND UNPUBLISHED WORK OF THE DESIGN PROFESSIONAL AND MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL PROJECT NUMBER DESCRIPTION SCALE PROJECT NAME AS SHOWN OWNER NAME OVALO KIZUNA LLC 25 E. HUNTINGTON DRIVE ARCADIA, CA 91006 HILTON ARCADIA 123 W HUNTINGTON DR. ARCADIA, CA 91007 LA21.522 JAPANESE RESTAURANT COMMERCIAL / RESIDENTIAL DESIGN & GENERAL CONSTRUCTION 1217 BUENA VISTA STREET, STE 102B. DUARTE. CA 91010 NO.DATE ISSUES & REVISIONS 06.19.25 TI PLAN CHECK 08.27.25 TI PLAN CHECK (2ND) 09.18.25 3rd HEALTH PLAN CHECK FOR R E F E R E N C E O N L Y . UND E R S E P A R A T E P E R M I T 11.26.25 TI PERMIT SET 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com SEISMIC EVALUATION AND RETROFIT of BLDG C for Hilton Arcadia Hotel 123 W. Huntington Drive Arcadia, CA 91006 for AXIS/GFA Architecture + Design 1130 Westwood Boulevard Los Angeles, CA 90024 Prepared by MHP, Inc. Structural Engineers Long Beach, California June 9, 2022 MHP JN: 19-0283-01 STRUCTURAL CALCULATIONS Version 23 October 9, 2023 4 November 12, 2023August 26, 2025 Hilton Arcadia HotelJapanese Restaurant S No.4101IS G E R OF C TA S T E R EF D P R O TE E I R E E N AINRFOILA A ONS L E N G I KE N N E T H D.O'D EL L U R A LTSRUCT November 25, 2025 19-0283-03 CALCULATION SHEET SUBJECT: DATE: JOB NO: BY: SHEET: H:\2019\190283\4_Engineering\Building C\Table of Contents.docm 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com Table of Contents C.22 INTERIOR METAL STUD EXHAUST HOOD ANCHORAGE TRANSFORMER ANCHORAGE Roof DAOS and KEF Page3 6 22 35 Section : 362S162-33 (33 ksi) @ 16" o.c. Single C Stud (punched) Maxo =440.9 ft-lb 1023.6 lbVa =I =0.55 in^4 Loads have not been modified for strength checks Loads have not been modified for deflection calculations Bridging Connectors - Design Method =AISI S100 Span KyLy, KtLt Flexual, Distortional Connector Stress Ratio Axial Span 48.0", 48.0"48.0", 192.0"LSUBH3.25 (Min)0.15 Web Crippling Support Load (lb)(in)Max Int.Stiffener? Bearing Pa M (lb)(ft-lbs) R2 53.33 --Slip Track Design, Ref Connectors--NO R1 53.33 --Stud/Track Design, Ref Connectors--NO Gravity Load Type Load (lb) Uniform 6.67plf Code Check Required Interaction NotesAllowed Max. Axial, lbs 106.7(c)8%KΦ=0.00 lb-in/in Max KL/r = 1321300.6(c)Span Max. Shear, lbs 53.3 10%Shear (Punched)521.2 Max. Moment (MaFy, Ma-dist), ft-lbs 213.3 48%MaFy (control),KΦ=0.00 lb-in/in440.9 Moment Stability, ft-lbs 213.3 49%431.9 Shear/Moment 0.48 48%Shear 0.0, Moment 213.31.00 Axial/Moment 0.54 54%Axial 55.6(c), Moment 213.01.00 Deflection Span, in 0.605 --meets L/318-- Support Rx(lb)Ry(lb)Simpson Strong-Tie Connector Connector Interaction Anchor Interaction 11.00 %R2 53.3 0.0 35.56 %362SLT250-33 (33) & (1) 3/8" x 2.5" embed Titen HD to 2500 psi min concrete 8.89 %R1 53.3 106.7 20.40 %362T125-33 (33) & (1) 3/8" x 2.5" embed Titen HD to 2500 psi min concrete * Reference catalog for connector and anchor requirement notes as well as screw placement requirements www.strongtie.comSIMPSON STRONG-TIE COMPANY INC. Project Name:TI Calc Model:Typical 2012 NASPEC [AISI S100-2012]Code: Page 1 of 1 Date: 08/26/2025 Simpson Strong-Tie® CFS Designer™ 5.2.8.0 3 Design Loads Wall Lateral Pressure : RO Lateral Pressure : Parapet Lateral Pressure : 5 psf Head/Sill Only Lateral element force multiplier Strength : Deflection :1 1.0 Gravity Load at Header:9 psf Box (lateral top, bottom)Header: Component(s)Members(s)Flexural Bracing Axial KyLy Axial KtLt Distortional K-Phi(lb-in/in) Distortional Lm Brace Settings Interconnection Spacing Wall Studs 362S162-33(33), Single@16 in o/c 48 in 48 in 0 None48 in N/A Jamb Studs 362S162-33(33), (2) Non-Composite 48 in 48 in 0 None48 in N/A Vertical Header 600S162-43(33), Boxed Full N/A 0 NoneN/A N/A Lat. Top Head 362T150-43(33), Single Full N/A 0 NoneN/A N/A Lat. Bottom Head 362T150-43(33), Single Full N/A 0 NoneN/A N/A Sill 362T150-43(33), Boxed Full N/A 0 NoneN/A N/A Component(s)Members(s) Axial Load (lb) Max. Moment (ft-lb) Max. Shear (lb) Bottom Reaction (lb) Top or End Reaction (lb) Analysis Results Max KL/r Wall Studs 362S162-33(33), Single@16 in o/c 0.0 43.3 43.3 43.3140.8N/A Jamb Studs 362S162-33(33), (2) Non-Composite 281.3 177.9 177.9 146.7691.7108 Vertical Header 600S162-43(33), Boxed N/A 281.3 N/A 281.3878.9N/A Lat. Top Head 362T150-43(33), Single N/A 78.1 N/A 78.1244.1N/A Lat. Bottom Head 362T150-43(33), Single N/A 78.1 N/A 78.1244.1N/A Sill 362T150-43(33), Boxed N/A 125.0 N/A 125.0390.6N/A Component(s)Members(s) Deflection A + M Interaction V + M Interaction Web Stiffners Design OK Design Results Span Parapet Wall Studs 362S162-33(33), Single@16 in o/c L/592 0.04 No Yes0.326L/0 Jamb Studs 362S162-33(33), (2) Non-Composite L/254 0.79 No Yes0.882L/0 Vertical Header 600S162-43(33), Boxed L/829 0.32 No Yes0.32NA Lat. Top Head 362T150-43(33), Single L/370 0.58 No Yes0.58NA Lat. Bottom Head 362T150-43(33), Single L/370 0.04 No Yes0.58NA Sill 362T150-43(33), Boxed L/463 0.46 No Yes0.46NA www.strongtie.comSIMPSON STRONG-TIE COMPANY INC. Project Name:TI Calc Model:1-Span Opening -1 2012 NASPEC [AISI S100-2012]Code: Page 1 of 2 Date: 08/26/2025 Simpson Strong-Tie® CFS Designer™ 5.2.8.0 4 Support Rx(lb)Ry(lb)Simpson Strong-Tie® Connector Connector Interaction Anchor Interaction Simpson Strong-Tie® Connectors @ Studs 55.81 %R2 43.33 0.00 28.89 %362SLT250-33 (33) & (1) .157", 3/4" embed SST PDPA/PDPAT to 2500 nw concrete 19.68 %R1 43.33 156.00 16.58 %362T125-33 (33) & (1) .157", 1" embed SST PDPA/PDPAT to 2500 nw concrete * Reference catalog for connector and anchor requirement notes as well as screw placements requirement Support Rx(lb)Ry(lb)Simpson Strong-Tie® Connector Connector Interaction Anchor Interaction Simpson Strong-Tie® Connectors @ Jambs 44.81 %R2 146.67 0.00 97.78 %362SLT250-33 (33) & (2) .157", 1" embed SST PDPA/PDPAT to 2500 nw concrete 40.40 %R1 177.92 407.25 45.63 %362T125-33 (33) & (2) .157", 1" embed SST PDPA/PDPAT to 2500 nw concrete * Reference catalog for connector and anchor requirement notes as well as screw placements requirement Span/Parapet Bracing Length(in.) Design Number of Braces Pn(lb.) SUBH (Min)¹SUBH (Max)¹ MSUBH (Min)¹ Simpson Strong-Tie® Wall Stud Bridging Connectors @ Studs MSUBH (Max)¹ LSUBH (Min)¹ LSUBH (Max)¹ Span 48 2968.5 OK (0.11)OK (0.10)No Soln4 No SolnOK (0.16)OK (0.10) Span/Parapet Bracing Length(in.) Design Number of Braces Pn(lb.) SUBH (Min)¹ SUBH (Max)¹ MSUBH (Min)¹ Simpson Strong-Tie® Wall Stud Bridging Connectors @ Jambs MSUBH (Max)¹ LSUBH (Min)¹ LSUBH (Max)¹ Span 48 N/A N/A N/A N/AN/A N/AN/A N/A 1) Values in parentheses are stress ratios. 2) Bridging connectors are not designed for back-back, box, or built-up sections. 3) Reference Notes: 4) CFS Designer will not select bridging connectors unless all flexural and axial bracing settings are the same. 5) If the bracing length is larger than the span length, bridging connectors are not designed. for latest load data, important information, and general notes. www.strongtie.com www.strongtie.comSIMPSON STRONG-TIE COMPANY INC. Project Name:TI Calc Model:1-Span Opening -1 2012 NASPEC [AISI S100-2012]Code: Page 2 of 2 Date: 08/26/2025 Simpson Strong-Tie® CFS Designer™ 5.2.8.0 5 SEISMIC FACTORS FOR EQUIPMENT ANCHORAGE Site: Floor (Level): Equipment: Seismic Design Force Factors: ap* Rp* o Ip z h SDS** amp factor response mod factor Omega (overstrength) Factor importance factor height of attach point average roof height design parameter at short periods 2.5 6 2 1.0 1 3 1.321 * ASCE 7-16, Table 13.5-1, 13.6-1 **See seismic coefficients on US Seismic Design Maps output Seismic Design Force for Equipment Anchorage 0.37 Wp (ASCE 7-16, Equation 13.3-1) 2.11 Wp (ASCE 7-16, Equation 13.3-2) 0.40 Wp (ASCE 7-16, Equation 13.3-3) Seismic Design Force Fp(H) =0.40 Wp 0.28 Wp Fp (V) = .2SDS 0.26 Wp 0.18 Wp (ASCE 7-16, Section 13.3.1.2) Overstrength Forces (Anchorage into Concrete (LRFD)) 3o*Fp(H)=0.79 Wp 0.55 Wp *No overstrength required for Fp(V) ASD (0.7 x LRFD)LRFD LRFD ASD (0.7 x LRFD) Hilton Arcadia Hotel Level 1 Exhaust Hood =0.4 / 1 + 2 ℎ= (min)= 0.3 = (max)=1.6 = H:\2019\190283\_19-0283-01 Hilton Arcadia Hotel (New Design)\8_Plan Review\TI plan check (1st Round)\TI Calcs\19-0283-03_Exhaust Hood Anchorage_2019 CBC1.xlsm 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www. 6 Suspended Equipment Anchor Forces (ASD) Unit Properties Unit Wp =900 lbs Anchorage Width, W =48 in Unit Height, HUNIT =24 in Rod Height, HROD =48 in Brace Properties Ɵ from the horizontal =45 ⁰ Lbrace length =68 in OK for Compression 8' max Lh =48 in Anchor Layout No. of Rods (Ea Side), NRODS = 2 No. of Braces (Ea Side), NBRACES=2 Forces on Unit (LRFD) Fp(H) =0.28 *Wp=250 lb Fp(V) =0.26 *Wp=238 lb Free Body Diagram of the brace alone demands that the bottom horizontal and vertical forces are equal and opposite to the forces at the top of the brace and that these forces are defined by the angle, length of rod and the horizontal load acting on the brace. Therefore, this spreadsheet uses separate freebodies for the unit and the brace and then superimposes the loads to the F2 rod. Only the horizontal load from the brace is applied to the unit free body because this is theonly load applied to the brace. An alternative free body could include the unit and brace with the reactions at the top of the brace included in the free body Seismic to left for tension brace (For tension only use this case only) (ASD) Free Body Diagram of unit assuming brace is horizontal ΣMB = 0 (eq. 6): F1max = =-224 lbs (Tension) ΣMA = 0 (Eq. 6): F2min unit = =-349 lbs (Tension) ΣMA = 0 (Eq. 5): F2max unit = -721 lbs (Tension) Free Body Diagram of brace with F2 and brace connection to deck providing supports F3(H) =Fp(H)=250 lbs F3 = -F3(H) / sin Ɵ =-353 lbs (Tension) ΣMc =0: F3(V) bottom (=F2brace) =(F3(H)*Hrod) / Lh =250 lbs (Compression) ΣMb =0: F3(V) top=-[(F3(H)*Hrod) / Lh =-250 lbs (Tension) Total rod force with superimposed brace and unit loads. Seismic to the Left F2total = F2brace + F2min unit =-99 lbs (Tension) Hood #1 [(Fp(H)*HUNIT/2) - ((.9Wp-Fp(V))*W/2)] / W -[(Fp(H)*HUNIT/2)+ ((.9Wp-Fp(V))*W/2)] / W -[(Fp(H)*HUNIT/2)+ ((1.2Wp+Fp(V))*W/2)] / W H:\2019\190283\_19-0283-01 Hilton Arcadia Hotel (New Design)\8_Plan Review\TI plan check (1st Round)\TI Calcs\19-0283-03_Exhaust Hood Anchorage_2019 CBC1.xlsm 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www. 7 Seismic to right (for compression brace need to consider both seismic directions in design) (ASD) Free Body Diagram of unit assuming brace is horizontal ΣMB = 0 (eq. 5): F1max = =-721 lbs (Tension) ΣMA = 0 (Eq. 5): F2min unit = =-596 lbs (Tension) ΣMA = 0 (Eq. 6): F2max unit = =-224 lbs (Tension) Free Body Diagram of brace with F2 and brace connection to deck providing supports F3(H) =Fp(H)=-250 lbs F3 = F3(H) / sin Ɵ =353 lbs (Compression) ΣMc =0: F3(V) bottom (=F2brace)=(F3(H)*Hrod) / Lh =-250 lbs (Tension) ΣMb =0: F3(V) top=[(-F3(H)*Hrod) / Lh =250 lbs (Compression) Rod force with total brace and unit loads. Seismic to the Right F2total = F2brace + F2min unit =-846 lbs (Tension) Rod / Brace Design Load Summary (for tension, only ignore comp. values) (ASD) Cmax,rod =(F1 or F2total) / NRODS =NO COMP lbs Tmax,rod =(F1 or F2total) / NRODS =-423 lbs Tmax or Cmax,brace =|F3 / NBRACES|=177 lbs TV at top of brace =F3(V) top / NBRACES =-125 lbs VH at top of brace =|F3(H)top / NBRACES |=125 lbs -[(-Fp(H)*HUNIT/2) + ((1.2Wp+Fp(V))*W/2)] / W -[(-Fp(H)*HUNIT/2) + ((0.9Wp-Fp(V))*W/2)] / W [(-Fp(H)*HUNIT/2) - ((1.2Wp+Fp(V))*W/2)] / W H:\2019\190283\_19-0283-01 Hilton Arcadia Hotel (New Design)\8_Plan Review\TI plan check (1st Round)\TI Calcs\19-0283-03_Exhaust Hood Anchorage_2019 CBC1.xlsm 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www. 8 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (2) hnom2 Item number: 2210254 KB-TZ2 1/2x3 3/4 Specification text: Hilti Æ 1/2 in Kwik Bolt TZ2 - CS with 2.5 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII, Effective embedment depth: hef,act = 2.000 in., hnom = 2.500 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 10/1/2024 | 12/1/2025 Proof: Design Method ACI 318-14 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-14 Fig. R.17.5.2.1b) Stand-off installation: Profile: Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 5.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) Geometry [in.] & Loading [lb, in.lb] 9 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 600; Vx = 0; Vy = 0; Mx = 0; My = 0; Mz = 0; yes 38 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 600 0 0 0 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*600 8,433 8 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**600 1,586 38 OK * highest loaded anchor **anchor group (anchors in tension) 3.1 Steel Strength Nsa [lb]f f Nsa [lb]Nua [lb] 11,244 0.750 8,433 600 3.2 Concrete Breakout Failure ANc [in.2]ANc0 [in.2]ca,min [in.]cac [in.]y c,N 36.00 36.00 ∞5.500 1.000 ec1,N [in.]y ec1,N ec2,N [in.]y ec2,N y ed,N y cp,N kcr 0.000 1.000 0.000 1.000 1.000 1.000 21 l a Nb [lb]f f seismic f Ncbg [lb]Nua [lb] 1.000 3,253 0.650 0.750 1,586 600 10 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*N/A N/A N/A N/A Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength*N/A N/A N/A N/A Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 5 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the equations remain in their imperial format. • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/ • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14, Chapter 17, Section 17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or Section 17.2.3.4.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.2.3.5.3 (a), Section 17.2.3.5.3 (b), or Section 17.2.3.5.3 (c). • Section 17.2.3.4.3 (b) / Section 17.2.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.2.3.4.3 (c) / Section 17.2.3.5.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.2.3.4.3 (d) / Section 17.2.3.5.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-14, Section 17.8.1. Fastening meets the design criteria! 11 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 6 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (2) hnom2 Profile: - Item number: 2210254 KB-TZ2 1/2x3 3/4 Hole diameter in the fixture: - Maximum installation torque: 602 in.lb Plate thickness (input): - Hole diameter in the base material: 0.500 in. Hole depth in the base material: 2.750 in. Drilling method: Hammer drilled Minimum thickness of the base material: 4.000 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti Æ 1/2 in Kwik Bolt TZ2 - CS with 2.5 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII 6.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---- 12 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 7 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 13 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (2) hnom2 Item number: 2210254 KB-TZ2 1/2x3 3/4 Specification text: Hilti Æ 1/2 in Kwik Bolt TZ2 - CS with 2.5 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII, Effective embedment depth: hef,act = 2.000 in., hnom = 2.500 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 10/1/2024 | 12/1/2025 Proof: Design Method ACI 318-14 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-14 Fig. R.17.5.2.1b) Stand-off installation: Profile: Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 5.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) Geometry [in.] & Loading [lb, in.lb] 14 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 400; Vx = 400; Vy = 0; Mx = 0; My = 0; Mz = 0; yes 26 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 400 400 400 0 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*400 8,433 5 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**400 1,586 26 OK * highest loaded anchor **anchor group (anchors in tension) 3.1 Steel Strength Nsa [lb]f f Nsa [lb]Nua [lb] 11,244 0.750 8,433 400 3.2 Concrete Breakout Failure ANc [in.2]ANc0 [in.2]ca,min [in.]cac [in.]y c,N 36.00 36.00 ∞5.500 1.000 ec1,N [in.]y ec1,N ec2,N [in.]y ec2,N y ed,N y cp,N kcr 0.000 1.000 0.000 1.000 1.000 1.000 21 l a Nb [lb]f f seismic f Ncbg [lb]Nua [lb] 1.000 3,253 0.650 0.750 1,586 400 15 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*400 3,599 12 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**400 2,277 18 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa [lb]aV,seis f f Vsa [lb]Vua [lb] 5,537 1.000 0.650 3,599 400 4.2 Pryout Strength ANc [in.2]ANc0 [in.2]ca,min [in.]kcp cac [in.]y c,N 36.00 36.00 ∞1 5.500 1.000 ec1,V [in.]y ec1,V ec2,V [in.]y ec2,V y ed,N y cp,N kcr 0.000 1.000 0.000 1.000 1.000 1.000 21 l a Nb [lb]f f seismic f Vcpg [lb]Vua [lb] 1.000 3,253 0.700 1.000 2,277 400 5 Combined tension and shear loads bN bV z Utilization bN,V [%]Status 0.252 0.176 5/3 16 OK bNV = bz N + bz V <= 1 16 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the equations remain in their imperial format. • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/ • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14, Chapter 17, Section 17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or Section 17.2.3.4.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.2.3.5.3 (a), Section 17.2.3.5.3 (b), or Section 17.2.3.5.3 (c). • Section 17.2.3.4.3 (b) / Section 17.2.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.2.3.4.3 (c) / Section 17.2.3.5.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.2.3.4.3 (d) / Section 17.2.3.5.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-14, Section 17.8.1. Fastening meets the design criteria! 17 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (2) hnom2 Profile: - Item number: 2210254 KB-TZ2 1/2x3 3/4 Hole diameter in the fixture: - Maximum installation torque: 602 in.lb Plate thickness (input): - Hole diameter in the base material: 0.500 in. Hole depth in the base material: 2.750 in. Drilling method: Hammer drilled Minimum thickness of the base material: 4.000 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti Æ 1/2 in Kwik Bolt TZ2 - CS with 2.5 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---- 18 Hilti PROFIS Engineering 3.1.19 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 19 Southern California Office REGION 86 PHONE: (714) 957 - 1500 EMAIL: reg86@captiveaire.com FOR QUESTIONS, CALL THE HOOD INFORMATION - JOB#7281290 1 2 5424 ND-2 4824 ND-2 CAPTIVEAIRE CAPTIVEAIRE 11' 6" 4' 0" 600 DEG 600 DEG I I HEAVY HEAVY 224 275 2575 1100 4" 4" 16" 10" 2575 1100 1844 2017 -1.258" -0.822" 430 SS WHERE EXPOSED 430 SS WHERE EXPOSED ALONE ALONE ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP HOOD CONSTRUCTION HOOD CONFIG END TO END ROW HOOD INFORMATION 1 2 CAPTRATE SOLO FILTER CAPTRATE SOLO FILTER 8 2 16" 20" 16" 20" 85% SEE FILTER SPEC 85% SEE FILTER SPEC 3 1 RECESSED ROUND RECESSED ROUND NO NO RIGHT RIGHT 12"x54"x24" 12"x48"x24" TANK FS TANK FS 4.0/4.0 4.0 SC-311110MA SC-311110MA 1 LIGHT 1 FAN 1 LIGHT 1 FAN YES YES 883 LBS 447 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT HOOD OPTIONS 1 2 BALANCE DAMPERS. RIGHT VERTICAL END PANEL 27" TOP WIDTH, 21" BOTTOM WIDTH, 80" HIGH INSULATED 430 SS. LEFT VERTICAL END PANEL 27" TOP WIDTH, 21" BOTTOM WIDTH, 80" HIGH INSULATED 430 SS. FIELD WRAPPER 18.00" HIGH FRONT, RIGHT. BACKSPLASH 80.00" HIGH X 61.00" LONG 430 SS VERTICAL. LEFT SIDESPLASH 80.00" HIGH X 48.00" LONG 430 SS VERTICAL. LEFT END STANDOFF (FINISHED) 1" WIDE 48" LONG INSULATED. BACKSPLASH - INSIDE CORNER 80.00" HIGH X 2.00" LEG LENGTH 430 SS VERTICAL. RIGHT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS. BALANCE DAMPERS. LEFT WALL AS END PANEL. HOOD NO TAG OPTION 1500500 FLOW RATE (CFM) 1000 0.00 0 0.50 PR E S S U R E D R O P ( i n . H 2 0 ) PRESSURE DROP VS. FLOW RATE RR SPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND COMPONENTS WHEN ASSEMBLED. 2-INCH DEEP HOOD CHANNEL(S). TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO FR A C T I O N A L E F F I C I E N C Y ( % ) 0 0.1 20 40 1.0 PARTICLE DIAMETER (UM) 10.0 EFFICIENCY VS. PARTICLE DIAMETER 60 80 100 THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. TE A NSF ACCORDANCE No. 96 NFPA WITH BUILT IN SLI DTE RO CH B N RAN I , OR M . YR OR LAIGNTSB AT CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96. NSF STANDARD #2. UL STANDARD #1046. INT. MECH. CODE (IMC). ULC-S649. 1.00 1.50 2.00 2.50 3.00 3.50 MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER. PATENT NUMBERS EXHAUST HOODS ND-2/BD-2/SND-2 (CANADA) - CA PATENT 2520435 C. 11' 6"NOM./11' 6.00"OD. 12'-6.00" OVERALL LENGTH 54" 12" UTILITY CABINET. 24 X 1 8 X 8 . 6 2 B O X 3" § 69"69" 12" ∅16" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. PLAN VIEW - HOOD #1 11' 6.00" LONG 5424ND-2 CLEARANCE TO COMBUSTIBLES HOODS #SURFACE *CLEARANCE 1 TOP 18" FRONT 0" BACK 18" LEFT 18" RIGHT 0" 2 TOP 18" FRONT 0" BACK 18" LEFT 0" RIGHT 0" - *0" CLEARANCE TO COMBUSTIBLES CONFORMS TO UL710 STANDARD. - HOOD MOUNTED UTILITY CABINETS REQUIRE 36" SERVICE CLEARANCE. 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. BALANCE DAMPERS. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. 20" 4" 4 1/2" 21" 27" 80" LEFT AND RIGHT VERTICAL END PANELS WITH ADJUSTABLE LEGS. GAS CHASE CUTOUT (FOR GAS AND POWER LINES). EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" SECTION VIEW - MODEL 5424ND-2 HOOD - #1 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 16" CAPTRATE SOLO FILTER WITH HOOK. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN SLI D TE R C U S 7281290 MASTER DRAWING DAB 1 1/17/2025 Hil t o n A r c a d i a - J a p a n e s e R e s t a u r a n t - R 1 3/4" = 1'-0" Ar c a d i a , C A , 9 1 0 0 6 So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m 20 4' 0"NOM./4' 0.00"OD. 5'-1.00" OVERALL LENGTH 48" 12" UTILITY CABINET. 24 X 1 8 X 8 . 6 2 B O X 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1" 3" § 24"24" 9" ∅10" U.L. LISTED RECESSED ROUND LED FIXTURE AND LED LIGHT. INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH THAT THE SPECIFIED WALL, ACTING AS AN END PANEL, IS MATED TIGHT TO THE CORRECT END OF HOOD TO ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING. NON-COMPLIANCE WILL NULLIFY THE ETL LISTING, VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS, AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING. PLAN VIEW - HOOD #2 4' 0.00" LONG 4824ND-2 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. FULL LENGTH HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). FULL LENGTH HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. BALANCE DAMPERS. HANGING ANGLE. RECESSED ROUND LED FIXTURE AND LED LIGHT, 3500 K WARM OUTPUT. BACKSPLASH 80.00" HIGH X 61.00" LONG. FIELD WRAPPER 18.00" HIGH (SEE HOOD OPTIONS TABLE). 23" 23" RIGHT QUARTER END PANEL. LEFT WALL AS END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 48" SECTION VIEW - MODEL 4824ND-2 HOOD - #2 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. BACKSPLASH HEIGHT - BACKSPLASH IS NOT INSULATED AND IS UNSUITABLE FOR INSTALL AGAINST COMBUSTIBLE WALLS BACKSPLASH PANELS SLIDE INTO DIVIDER BAR NON-COMBUSTIBLE WALL LENGTH SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NFP A WIT H IN SLI D TE R C U S 7281290 MASTER DRAWING DAB 2 1/17/2025 Hil t o n A r c a d i a - J a p a n e s e R e s t a u r a n t - R 1 3/4" = 1'-0" Ar c a d i a , C A , 9 1 0 0 6 So u t h e r n C a l i f o r n i a O f f i c e 30 0 2 D o w A v e . , S u i t e 2 0 2 , T u s t i n , C A , 9 2 7 8 0 P H O N E : ( 7 1 4 ) 9 5 7 - 1 5 0 0 F A X : 9 1 9 2 2 7 5 9 7 5 E M A I L : r e g 8 6 @ c a p t i v e a i r e . c o m 21 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 22 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 3/8 (1 1/2) hnom1 Item number: 2210234 KB-TZ2 3/8x2 1/2 Specification text: Hilti Æ 3/8 in Kwik Bolt TZ2 - CS with 1.875 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII Effective embedment depth: hef,act = 1.500 in., hnom = 1.875 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 10/1/2024 | 12/1/2025 Proof: Design Method ACI 318-14 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-14 Fig. R.17.5.2.1b) Stand-off installation: Profile: Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 5.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) Geometry [in.] & Loading [lb, in.lb] 23 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 463; Vx = 0; Vy = 0; Mx = 0; My = 0; Mz = 0; yes 45 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 463 0 0 0 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*463 4,869 10 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**463 1,030 45 OK * highest loaded anchor **anchor group (anchors in tension) 3.1 Steel Strength Nsa [lb]f f Nsa [lb]Nua [lb] 6,493 0.750 4,869 463 3.2 Concrete Breakout Failure ANc [in.2]ANc0 [in.2]ca,min [in.]cac [in.]y c,N 20.25 20.25 ∞5.000 1.000 ec1,N [in.]y ec1,N ec2,N [in.]y ec2,N y ed,N y cp,N kcr 0.000 1.000 0.000 1.000 1.000 1.000 21 l a Nb [lb]f f seismic f Ncbg [lb]Nua [lb] 1.000 2,113 0.650 0.750 1,030 463 24 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*N/A N/A N/A N/A Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength*N/A N/A N/A N/A Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 5 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (EN1992-4, AS5216, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the equations remain in their imperial format. • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/ • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14, Chapter 17, Section 17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or Section 17.2.3.4.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.2.3.5.3 (a), Section 17.2.3.5.3 (b), or Section 17.2.3.5.3 (c). • Section 17.2.3.4.3 (b) / Section 17.2.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.2.3.4.3 (c) / Section 17.2.3.5.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.2.3.4.3 (d) / Section 17.2.3.5.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-14, Section 17.8.1. Fastening meets the design criteria! 25 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 6 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 3/8 (1 1/2) hnom1 Profile: - Item number: 2210234 KB-TZ2 3/8x2 1/2 Hole diameter in the fixture: - Maximum installation torque: 361 in.lb Plate thickness (input): - Hole diameter in the base material: 0.375 in. Hole depth in the base material: 2.000 in. Drilling method: Hammer drilled Minimum thickness of the base material: 3.250 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti Æ 3/8 in Kwik Bolt TZ2 - CS with 1.875 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII 6.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---- 26 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 7 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 27 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ2 - CS 3/8 (1 1/2) hnom1 Item number: 2210234 KB-TZ2 3/8x2 1/2 Specification text: Hilti Æ 3/8 in Kwik Bolt TZ2 - CS with 1.875 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII Effective embedment depth: hef,act = 1.500 in., hnom = 1.875 in. Material: Carbon Steel Evaluation Service Report: ESR-4266 Issued I Valid: 10/1/2024 | 12/1/2025 Proof: Design Method ACI 318-14 / Mech Shear edge breakout verification: Row closest to edge (Case 3 only from ACI 318-14 Fig. R.17.5.2.1b) Stand-off installation: Profile: Base material: cracked concrete, 3000, fc' = 3,000 psi; h = 5.000 in. Installation: Hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) Tension load: yes (17.2.3.4.3 (d)) Shear load: yes (17.2.3.5.3 (c)) Geometry [in.] & Loading [lb, in.lb] 28 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 1.1 Design results Case Description Forces [lb] / Moments [in.lb]Seismic Max. Util. Anchor [%] 1 Combination 1 N = 152; Vx = 152; Vy = 0; Mx = 0; My = 0; Mz = 0; yes 15 2 Load case/Resulting anchor forces Anchor reactions [lb] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 152 152 152 0 3 Tension load Load Nua [lb]Capacity f Nn [lb]Utilization bN = Nua/f Nn Status Steel Strength*152 4,869 4 OK Pullout Strength*N/A N/A N/A N/A Concrete Breakout Failure**152 1,030 15 OK * highest loaded anchor **anchor group (anchors in tension) 3.1 Steel Strength Nsa [lb]f f Nsa [lb]Nua [lb] 6,493 0.750 4,869 152 3.2 Concrete Breakout Failure ANc [in.2]ANc0 [in.2]ca,min [in.]cac [in.]y c,N 20.25 20.25 ∞5.000 1.000 ec1,N [in.]y ec1,N ec2,N [in.]y ec2,N y ed,N y cp,N kcr 0.000 1.000 0.000 1.000 1.000 1.000 21 l a Nb [lb]f f seismic f Ncbg [lb]Nua [lb] 1.000 2,113 0.650 0.750 1,030 152 29 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 4 Shear load Load Vua [lb]Capacity f Vn [lb]Utilization bV = Vua/f Vn Status Steel Strength*152 2,097 8 OK Steel failure (with lever arm)*N/A N/A N/A N/A Pryout Strength**152 1,479 11 OK Concrete edge failure in direction **N/A N/A N/A N/A * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength Vsa [lb]aV,seis f f Vsa [lb]Vua [lb] 3,226 1.000 0.650 2,097 152 4.2 Pryout Strength ANc [in.2]ANc0 [in.2]ca,min [in.]kcp cac [in.]y c,N 20.25 20.25 ∞1 5.000 1.000 ec1,V [in.]y ec1,V ec2,V [in.]y ec2,V y ed,N y cp,N kcr 0.000 1.000 0.000 1.000 1.000 1.000 21 l a Nb [lb]f f seismic f Vcpg [lb]Vua [lb] 1.000 2,113 0.700 1.000 1,479 152 5 Combined tension and shear loads bN bV z Utilization bN,V [%]Status 0.148 0.103 5/3 7 OK bNV = bz N + bz V <= 1 30 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 6 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (EN1992-4, AS5216, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • The equations presented in this report are based on imperial units. When inputs are displayed in metric units, the user should be aware that the equations remain in their imperial format. • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. • Refer to the manufacturer's product literature for cleaning and installation instructions. • For additional information about ACI 318 strength design provisions, please go to https://viewer.joomag.com/profis-design-guide-us-en-summer-2021/0841849001625154758?short&/ • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14, Chapter 17, Section 17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or Section 17.2.3.4.3 (d). The connection design (shear) shall satisfy the provisions of Section 17.2.3.5.3 (a), Section 17.2.3.5.3 (b), or Section 17.2.3.5.3 (c). • Section 17.2.3.4.3 (b) / Section 17.2.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.2.3.4.3 (c) / Section 17.2.3.5.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Section 17.2.3.4.3 (d) / Section 17.2.3.5.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by w0. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-14, Section 17.8.1. Fastening meets the design criteria! 31 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 7 Installation data Anchor type and diameter: Kwik Bolt TZ2 - CS 3/8 (1 1/2) hnom1 Profile: - Item number: 2210234 KB-TZ2 3/8x2 1/2 Hole diameter in the fixture: - Maximum installation torque: 361 in.lb Plate thickness (input): - Hole diameter in the base material: 0.375 in. Hole depth in the base material: 2.000 in. Drilling method: Hammer drilled Minimum thickness of the base material: 3.250 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Hilti Æ 3/8 in Kwik Bolt TZ2 - CS with 1.875 in nominal embedment depth per ICC-ES ESR-4266 , Hammer drill bit installation per MPII 7.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Manual blow-out pump • Torque controlled cordless impact tool • Torque wrench • Hammer Coordinates Anchor in. Anchor x y c-x c+x c-y c+y 1 0.000 0.000 ---- 32 Hilti PROFIS Engineering 3.1.24 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2025 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. 33 r---20.00 _____, I [5oaJ I r :,.,:~7' .. : [762l <I b>-' ----.1-T + )01 [280] ]'-.63 OIA .~.50 I I (16] I I I I (4 PLS) I I l_J Tlj 1--18.00 __ -1 [457] 22.00 1-----:1-=a-=.o-=o-[559]- [69] ~~~~~~IEL0 :rl<=2=f=·=~B=~::::t:=-2~f·=~=~: ~ {WS363) ·'-" " "' 4.00 ---'~11-/-1 I) [102] 1 r ~PPROXIMATE .63 --ll--[16] v CENTER OF GRAVITY . J:::-[::;:-.:1 v 10.00 ,..· .. ·~ 'I' 6 00 1 [254] :/ .·1 ..... [isz] r 11 ~50 -r-"""li~·~::"'~:"·j _____ --.1 [292] 4.00+--~·-H [102] ACCESSORY WALL MOUNTING (WI-48363-364) 1 13.25 I [337] ~_j BRACKETS [16] I" 14.00 .6.3 DIA~ '---' [457] (4 Pl.S) !---[>5~-i 1 .63 [16] ,5.50 [14-0] olf 1 1 . ti:·~:L:·:;.:~;jl-·+----'- [391] . j ~ 1ACCESSORY CEILING MOUNTING BRACKErS .L---{~~:;_;:;_;;;~:;..;:;H•¥l Ct-48363) NOTES: L.S0/[13] X .BB/[22] !ATG SLOT (4 PLACES) 1) cULus USTED (MEETING UL 1561 AND CSA C22.2) 2) NEMA 2 VENllLATED ENCLOSURE ENCLOSURE RATED FOR NEMA 3R WHEN OPllONAL WEATHERSHIELO ACCESSORY IS INSTALLED. 3) MINIMU!A CLEARANCE OF 3.00/[76] BETWEEN VENT OPENINGS, WALL OR OTHER OBSTRUCTION SEISMIC QUAUFlCATION: TO BE COMPLIANT WITH THE SEISMIC REQUIREMENTS OF ASCE/SEI 7, THIS UNIT HAS BEEN QUALIFIED BY SHAKE TABLE TESTING THROUGH SELF CERTIFICATION TO ICC ES AC156. THE ENCLOSURE SHOWN ABOVE IS 1BD. CONTACT YOUR LOCAL SCHNEIDER ELECTRIC/SQUARE D REPRESENTAllVE FOR RELATED QUESllONS. LOW VOLTAGE ENERGY EFFICIENT, TP1 DRY TYPE TRANSFORMER CATALOG NO EE4ST3H 4) SHADED AREAS DENOTE CUSTO!AER CONDUIT ENTRANCE LOCATIONS, AVAILABLE BOTH SIDES AND BOTTOM 3 PHASE, 45kVA, AL PRit.1ARY4BO DELTA ,SECONDARY 20BY/120 JUNE 2014 IN EACH PHASE CONNECT TO TAPS PRIMARY VOLTS 2 2.5" FCAN 4-2.5';11; FCBN 504 1 492 2 460 ' 466 4 456 5 444 6 4J2 7 1""""1 1""""1 1""""1 XO X1 X2 X3 L H1 H3 X2 x~-xo " TRANSFORMER SPECIFICATIONS: 45 KVA 3113 60HZ PRIMARY VOLTAGE +50 DELTA SECONDARY VOLTAGE 208Y /120 150 'C RISE ABOVE 40'C At.481ENT 220 'C INSULATION SYSTEM ALUMINUM WINDINGS APPROXIt.IATE WEIGHT: 368 LBS GUARANTEED SOUND LEVEL: 45 dB EFFICIENCY 03571:: 97.7X AVG. CONFORMS TO NEMA TP 1 -2002 AND CSA CB02.2 . INCHES DUAL DIMENSIONS. !AILLIMETERS II¥ Schneider Electric ~~ 6312-0003 SHEET 1 OF 2 34 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com DN 13.5 14 CS4.3 14 CS4.3 W14x22 10 CS5.1 10 CS5.1 HS S 6 x 6 x 3 / 8 W1 8 x 3 5 HSS4x4x3/8 HS S 4 x 4 x 1 / 4 W16x26 EXTEND COL TO STAIR ROOF (2 LOCS) EQ EQEQEQEQEQ EQEQEQQ L3x3x1/4 BRACE TYP MAX OP WT=1,500# (E) W8x10 (E) W8x10 (E)W12x14 (E)W12x14 (E)W12x14 (E)W16x26 (E)W14x22 (E)W12x14 (E)W12x14 (E)W12x14 (E)W14x22 (E ) W 8 x 1 0 (E ) W 8 x 1 0 (E) W14x26 (E) W8x10 (E ) W 2 1 x 4 4 (E)W16x26 (E)W12x14 (E)W16x26 (E ) W 2 1 x 4 4 (E ) W 1 2 x 1 4 (E ) W 1 2 x 1 4 (E ) W 1 2 x 1 4 (E ) W 1 2 x 1 4 (E ) W 1 8 x 3 5 (E ) W 1 8 x 4 0 (E)W8x10 (E)W8x10 D3 W14x22 W1 4 x 2 2 (E)W12x14 (E)W12x14 WT3x6 WT3x6 W16x26 W14x22 13 CS4.6 CONC FILL ONLY OCCURS IN HATCHED AREA, TYP W1 4 x 2 2 D3 13 CS4.5 5 CS5.3 7 CS4.4 TYP AT HSS TO HSS (E)W12x14 OP 920# (E)W8x10 6 CS5.3 (E)W12x14 DAOS 3 MAX OP WT=2,800# KEF 3 MAX OP WT=750# (E ) W 1 2 x 1 4 INDICATES BEAM STRENGTHENING PL PER 18 CS4.1 W1 4 x 2 2 KEF 4 MAX OP WT=750# (E)W12x14 W1 4 x 2 2 15 CS4.4 HSS6x6x1/4 (2 LOCS) PER 5 CS4.1 W1 8 x 3 5 17 CS4.1 A 7.5' A 4' A 4' HSS4X4X3/8 UNIT SUPPORT CHANNELS PER 2 CS7.1 5 CS4.4 TYP (E ) W 8 x 1 0 A 7.5' 8'- 3 " 7' - 4 " 250lb 425lb 10'-0" 5' - 0 " 35 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com DAOS2850LB/2=1425lb/(91"/12)=188plf KEFPlatform 5' x 10'Unit Weight total + curb = 425lb+250lb=675lb/5x10=13.5psf+10psf (platform)=24psfEqually Spaced Channels = 3.33ft spacing wd=24psf*2.5ft = 60plfRd=60plfx3.33ft=200lb 8.25ft 5ft 7.33ft 7'-7"3'-3"4'-9" 8.25ft 36 Steel Beam LIC# : KW-06014612, Build:20.23.08.01 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2023 DESCRIPTION:C12x25 @ DOAS Project File: Bulletin 10.ec6 Project Title:Engineer:Project ID:Project Descr: CODE REFERENCES Calculations per AISC 360-16, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Analysis Method : ksi Bending Axis :Minor Axis Bending Completely Unbraced Load Resistance Factor Design Fy : Steel Yield :36.0 ksi Beam Bracing :E: Modulus :29,000.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Beam self weight NOT internally calculated and added Uniform Load : D = 0.1880 k/ft, Tributary Width = 1.0 ft, (DOAS) .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.277: 1 Load Combination +1.40D Span # where maximum occurs Span # 1 1.086 k Mn * Phi : Allowable 8.078 k-ft Vn * Phi : Allowable C12x25Section used for this span Span # where maximum occurs Location of maximum on span Span # 1 Load Combination +1.40D 59.411 k Section used for this span C12x25 Mu : Applied Maximum Shear Stress Ratio =0.018 : 1 0.000 ft 2.239 k-ft Vu : Applied 0 <360 649Ratio =0 <180 Maximum DeflectionMax Downward Transient Deflection 0 in 0Ratio =<360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.153 in Ratio =>=180Max Upward Total Deflection 0 in n/a n/a Span: 1 : D Onlyn/a .Maximum Forces & Stresses for Load Combinations Span # Summary of Moment Values Summary of Shear ValuesLoad Combination Max Stress Ratios M V max Mu -max Mu +Rm VnyMu Max Phi*Mny Cb VuMaxMny Phi*VnySegment Length +1.40D Dsgn. L = 8.25 ft 1 0.277 0.018 2.24 2.24 8.98 8.08 1.14 1.00 1.09 66.01 59.41 +1.20D Dsgn. L = 8.25 ft 1 0.238 0.016 1.92 1.92 8.98 8.08 1.14 1.00 0.93 66.01 59.41 +0.90D Dsgn. L = 8.25 ft 1 0.178 0.012 1.44 1.44 8.98 8.08 1.14 1.00 0.70 66.01 59.41 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections D Only 1 0.1525 4.149 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.776 0.776 Max Upward from Load Combinations 0.465 0.465 Max Upward from Load Cases 0.776 0.776 D Only 0.776 0.776 +0.60D 0.465 0.465 37 Steel Beam LIC# : KW-06014612, Build:20.23.08.01 MYERS, HOUGHTON PARTNERS (c) ENERCALC INC 1983-2023 DESCRIPTION:C12x25 @ KEF Project File: Bulletin 10.ec6 Project Title:Engineer:Project ID:Project Descr: CODE REFERENCES Calculations per AISC 360-16, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Analysis Method : ksi Bending Axis :Minor Axis Bending Completely Unbraced Load Resistance Factor Design Fy : Steel Yield :36.0 ksi Beam Bracing :E: Modulus :29,000.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Beam self weight NOT internally calculated and added Load(s) for Span Number 1 Point Load : D = 0.20 k @ 1.625 ft, (KEF) Point Load : D = 0.20 k @ 6.625 ft, (KEF) .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.056: 1 Load Combination +1.40D Span # where maximum occurs Span # 1 0.280 k Mn * Phi : Allowable 8.078 k-ft Vn * Phi : Allowable C12x25Section used for this span Span # where maximum occurs Location of maximum on span Span # 1 Load Combination +1.40D 59.411 k Section used for this span C12x25 Mu : Applied Maximum Shear Stress Ratio =0.005 : 1 0.000 ft 0.455 k-ft Vu : Applied 0 <360 2806Ratio =0 <180 Maximum DeflectionMax Downward Transient Deflection 0 in 0Ratio =<360 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.035 in Ratio =>=180Max Upward Total Deflection 0 in n/a n/a Span: 1 : D Onlyn/a .Maximum Forces & Stresses for Load Combinations Span # Summary of Moment Values Summary of Shear ValuesLoad Combination Max Stress Ratios M V max Mu -max Mu +Rm VnyMu Max Phi*Mny Cb VuMaxMny Phi*VnySegment Length +1.40D Dsgn. L = 8.25 ft 1 0.056 0.005 0.46 0.46 8.98 8.08 1.00 1.00 0.28 66.01 59.41 +1.20D Dsgn. L = 8.25 ft 1 0.048 0.004 0.39 0.39 8.98 8.08 1.00 1.00 0.24 66.01 59.41 +0.90D Dsgn. L = 8.25 ft 1 0.036 0.003 0.29 0.29 8.98 8.08 1.00 1.00 0.18 66.01 59.41 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections D Only 1 0.0353 4.149 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.200 0.200 Max Upward from Load Combinations 0.120 0.120 Max Upward from Load Cases 0.200 0.200 D Only 0.200 0.200 +0.60D 0.120 0.120 38 SEISMIC FACTORS FOR EQUIPMENT ANCHORAGE Site: Floor (Level): Equipment: Seismic Design Force Factors: ap* Rp* o Ip z h SDS** amp factor response mod factor Omega (overstrength) Factor importance factor height of attach point average roof height design parameter at short periods 2.5 2 2 1.0 1 1 1.321 * ASCE 7-16, Table 13.5-1, 13.6-1 **See seismic coefficients on US Seismic Design Maps output Seismic Design Force for Equipment Anchorage 1.98 Wp (ASCE 7-16, Equation 13.3-1) 2.11 Wp (ASCE 7-16, Equation 13.3-2) 0.40 Wp (ASCE 7-16, Equation 13.3-3) Seismic Design Force Fp(H) =1.98 Wp 1.39 Wp Fp (V) = .2SDS 0.26 Wp 0.18 Wp (ASCE 7-16, Section 13.3.1.2) Overstrength Forces (Anchorage into Concrete (LRFD)) 4o*Fp(H)=3.96 Wp 2.77 Wp *No overstrength required for Fp(V) ASD (0.7 x LRFD)LRFD LRFD ASD (0.7 x LRFD) Hilton Arcadita Hotel Roof DOAS, KEF =0.4 / 1 + 2 ℎ= (min)= 0.3 = (max)=1.6 = H:\2019\190283\_19-0283-01 Hilton Arcadia Hotel (New Design)\4_Engineering\1.0_Building C\Bulletin 10.xlsm 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 39 Floor Mounted Equipment Anchor Forces (ASD) Unit Properties Unit Wp =2834.3 lbs Anchorage Width, W =59 in Anchorage Length, L =90.5 in Height, H =77 in CG =51 in Anchor Layout Nanchors, W = Each Side, Parallel to W 4 Nanchors, L = Each Side, Parallel to L 9 Shared Corner Anchors (If YES, then 100+30 considered)NO NAnchors, Total = 26 Forces on Unit (ASD) Fp(H) =1.39 *Wp=3931 lb Fp(V) =0.18 *Wp=524 lb Mult =Fp(H)*CG =202 k-in Mresist (OT Parallel to W) =.6*Wp*W/2 =50 k-in Mresist (OT Parallel to L) =.6*Wp*L/2 =77 k-in Forces on Anchors (ASD) Tult (OT Parallel to W) =+Fp(V)=306 lbs NAnchors, Total Tult (OT Parallel to L) =+Fp(V)=365 lbs NAnchors, Total Tult (100+30) ==N/A lbs Tult (ASD) =Tult (OT Parallel to L) ==365 lbs Vult (ASD) =Fp(H) / NAnchors, Total =151 lbs 1.0*Tmax+0.3*Tmin DAOS ( Mult - Mresist (OT parallel to W) ) (W * Nanchors, L) (Mult - Mresist (OT parallel to L) ) (L * Nanchors, W) H:\2019\190283\_19-0283-01 Hilton Arcadia Hotel (New Design)\4_Engineering\1.0_Building C\Bulletin 10.xlsm 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 40 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 99" 96 3/4" 23" 42 1/2" 5 5/8" 21 5/8" 44" 37 1/4" DISCHARGE CUTOUT. 69" 52 3/4" 65 1/4" 1" NPT SS EVAPORATOR DRAIN (TRAP REQ'D). 4" MINIMUM TRAP DEPTH. 7 1/4" 7 1/2" LOUVERED OUTSIDE AIR INTAKE. 652 LBS 791 LBS 567 LBS468 LBS CENTER OF MASS. ENTERING POWER. MIN. 23" MINIMUM STRAIGHT DUCT PER AMCA* 91" 4" 14" 59 1/2" CURB OUTLINE 2 5/8" 17 1/2" 91"x59 1/2". 1" NPT GAS CONN.. 89 3/4" FACTORY INSTALLED SAFETY DISCONNECT SWITCH. ONLY USE COPPER WIRING FOR UNIT SUPPLY TO DISCONNECT. 6" 26 3/16" 91" 87 1/2" BASE CURB I.D. 5" 2 1/2" 93 1/2" 14" 59 1/2" 2" 56"BASE CURB I.D. 62" 16 5/8" 49 5/8" 73 1/8" 45 3/8" 48 3/8" 5( 7 8 5 1 6833/< RETURN SUPPLY S:\CURBS_CURB_ADAPTERS\7-XXXX-XXXX_ISO_CURBS_RAIL\SINGLE DOOR ISO CURBS\7000's\7770\7-0014-7770\ STANDARD CONSTRUCTION DETAILS '8&7)/(;&211(&7,2163529,'('%<27+(56 ,168/$7('3$1(/6:+(5(5(48,5(' ;:22'1$,/(5 635,1*$&&(66'2256$5(*$6.(7('$1'6&5(:('21 *$6.(70$7(5,$/3529,'(')257+(7233(5,0(7(5,1&/8',1*%5$&(6 635,1*3$&.60$<5(48,5(),(/'$'-8670(17%<27+(56 )8//<:(/'('*$/9$1,=('*˝&216758&7,21 :($7+(56($/%(7:((1833(5/2:(56(&7,2163529,'('%8/%6($/ REVISIONS REV.ECO#DESCRIPTION DATE APPROVED 1 INITIAL DRAWING 2/13/2025 ZS '$7( CDI &+(&.('˛ '5$:1˛ ',0(16,216$5($6)2//2:6˛LQ>˘PP@ 5'$1*/(352-(&7,21 $33529$/6 (&2˛ 6&$/(˛6+((7˛ 7,7/(˛ ),/(1$0(˛'5$:,1*12˛ 2) 5(9˛ ',0(16,21('$1'72/(5(1&('3(5$16,<˘0˝˙ 7-0014-7770 1:25 1 6 .. ˆ˘ˇ7</(5671:(/.5,9(501˘˘ˆˇ˝ˆˆ˝ ˆˇ˝ˆ˙˘ 81/(6627+(5:,6(63(&,),('72/(5$1&(6$5(˛ ;˘;;;; ˆ;;;˜6&85%6+2:1,6&',67$1'$5'&21),*85$7,21&',5(6(59(67+(5,*+772 &+$1*(/$<287:,7+287127,),&$7,21,)&85%,61(('(',1$',))(5(17 &21),*85$7,21&',0867%(127,),('35,25723/$&,1*$125'(5 7-0014-7770 9(5,)<(;,67,1*&85%2'9(5,)<6833/<$1'5(785123(1,1*6127($1<&+$1*(6&$//:,7+$1<48(67,216)$;%$&.,)'5$:,1*,62.$6,6 &85%:(,*+7/%6 zschellenberger Thursday, February 13, 2025 12:52:16 PM 356.33 41 Floor Mounted Equipment Anchor Forces (ASD) Unit Properties Unit Wp =423 lbs Anchorage Width, W =25 in Anchorage Length, L =31 in Height, H =42 in CG =28 in Anchor Layout Nanchors, W = Each Side, Parallel to W 3 Nanchors, L = Each Side, Parallel to L 2 Shared Corner Anchors (If YES, then 100+30 considered)YES NAnchors, Total = 6 Forces on Unit (ASD) Fp(H) =1.39 *Wp=587 lb Fp(V) =0.18 *Wp=78 lb Mult =Fp(H)*CG =16 k-in Mresist (OT Parallel to W) =.6*Wp*W/2 =3 k-in Mresist (OT Parallel to L) =.6*Wp*L/2 =4 k-in Forces on Anchors (ASD) Tult (OT Parallel to W) =+Fp(V)=278 lbs NAnchors, Total Tult (OT Parallel to L) =+Fp(V)=147 lbs NAnchors, Total Tult (100+30) ==322 lbs Tult (ASD) =Tult (100+30) ==322 lbs Vult (ASD) =Fp(H) / NAnchors, Total =98 lbs 1.0*Tmax+0.3*Tmin KEF 3 ( Mult - Mresist (OT parallel to W) ) (W * Nanchors, L) (Mult - Mresist (OT parallel to L) ) (L * Nanchors, W) H:\2019\190283\_19-0283-01 Hilton Arcadia Hotel (New Design)\4_Engineering\1.0_Building C\Bulletin 10.xlsm 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 42 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 42 1/8" 28 3/8" 26 1/4" 20" 40 5/8" 22" 31 7/8" 2" DRAIN. 35" 37 1/2" *OUTLET NOTES. 26 1/4" 35" TOP VIEW 37 1/2" FRONT VIEWSIDE VIEW 19 1/2"14 5/8" *INLET NOTES. 1 1/8" SHAFT DIA. FAN #1 USBI18DD-RM - EXHAUST FAN 24" EXTENSION. 25"18 1/4"12 3/4" (6) ISOLATORS = USBI18 THRU 36. 7.25" 4.125" SERVICE DUCT 43 Floor Mounted Equipment Anchor Forces (ASD) Unit Properties Unit Wp =246 lbs Anchorage Width, W =16.625 in Anchorage Length, L =25.625 in Height, H =31 in CG =21 in Anchor Layout Nanchors, W = Each Side, Parallel to W 3 Nanchors, L = Each Side, Parallel to L 2 Shared Corner Anchors (If YES, then 100+30 considered)YES NAnchors, Total = 6 Forces on Unit (ASD) Fp(H) =1.39 *Wp=341 lb Fp(V) =0.18 *Wp=45 lb Mult =Fp(H)*CG =7 k-in Mresist (OT Parallel to W) =.6*Wp*W/2 =1 k-in Mresist (OT Parallel to L) =.6*Wp*L/2 =2 k-in Forces on Anchors (ASD) Tult (OT Parallel to W) =+Fp(V)=183 lbs NAnchors, Total Tult (OT Parallel to L) =+Fp(V)=75 lbs NAnchors, Total Tult (100+30) ==205 lbs Tult (ASD) =Tult (100+30) ==205 lbs Vult (ASD) =Fp(H) / NAnchors, Total =57 lbs 1.0*Tmax+0.3*Tmin KEF 4 ( Mult - Mresist (OT parallel to W) ) (W * Nanchors, L) (Mult - Mresist (OT parallel to L) ) (L * Nanchors, W) H:\2019\190283\_19-0283-01 Hilton Arcadia Hotel (New Design)\4_Engineering\1.0_Building C\Bulletin 10.xlsm 3900 Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 44 CALCULATION SHEET SUBJECT:DATE:JOB NO: BY:SHEET: C:\Users\sfigueria\Documents\Blank Calc Sht1 3900 E. Cover Street, Long Beach, CA 90808 562.985.3200 P 562.985.1011 F www.mhpse.com 31 3/8" 20 7/8" 19 5/8" 14" 29 7/8" 18 1/4" 26 1/2" 2" DRAIN. 26" 31" *OUTLET NOTES. 19 5/8" 26" TOP VIEW 31" FRONT VIEWSIDE VIEW 14"11 3/4" *INLET NOTES. 7/8" SHAFT DIA. FAN #2 USBI13DD-RM - EXHAUST FAN 24" EXTENSION. SERVICE DUCT 45