Loading...
HomeMy WebLinkAbout501 S First Ave - 2025 - Medical Office TIS100 01 GENERAL NOTES & INFO. A L L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F F T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E H W A N G S T R U C T U R A L E N G I N E E R S I N C . C O P Y R I G H T A L L R I G H T S R E S E R V E D . DRAWN BY LAST REVISED DATE PROJECT NO. SHEET TITLE DRAWING NO. SHEET:OF: [25-05033] Engineer Seal: 50 1 S 1 s t A v e . M e d i c a l O f f i c e R e m o d e l Project : 04 - - 50 1 S 1 s t A v e . Ar c a d i a , C A 9 1 0 0 6 2025/05/22 R E R LR S G A E F G E L N O G A W E HDOETS AHN A J T U T E T I UC L I F R O S T U F R No. 5592 Exp.06-30-25 C A IOSSENPRO N N I IA E R N 2 4 5 0 W M a i n S t . Alhambra, CA 91801 j u n o @ h w a n g s e .c o m T e l . 2 1 3 ) 2 6 8 -0 9 3 5 StructuralEngineer s I nc. Revisions DESCRIPTIONNO. ABBREVIATIONS SYMBOLS SHEET INDEX INFO. N 01NORTH ARROW TOP OF FLOOR ELEVATION EARTH GRAVEL MATCHLINE SHEET NUMBER DETAIL NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NAME PLAN NUMBER PLAN ELEVATION SECTION EL ±0'-0" # / #-# # / #-# # # # # # # P. SHEET NO.SHEET TITLE 1.S100 GENERAL NOTES & INFO. 2.S200 FOUNDATION PLAN 3.S201 1ST. FLOOR WALLS & ROOF FRAMING PLAN 4.S300 DETAILS & SECTION &AND @ ATØDIAMETER A.B.ANCHOR BOLTA.C.I.AMERICAN CONCRETE INSTITUTE A.I.S.C.AMERICAN INSTITUTE OF STEEL CONSTRUCTIONALT.ALTERNATE ASSN.ASSOCIATION APPROX.APPROXIMATELY ARCH.ARCHITECTURAL A.S.T.M.AMERICAN STANDARD FOR TESTING AND MATERIALSA.W.S.AMERICAN WELDING SOCIETY (B), BOT.BOTTOMBET.BETWEEN BF BRACED FRAMEBLDG.BUILDING BLK.BLOCK BLKG BLOCKING BM.BEAM B.N.BOUNDARY NAILINGB.S.BOTH SIDES C CHANNEL OF CAMBER CANT CANTILEVER CAT.CATALOGCB.CEILING BEAM C.B.C.CALIFORNIA BUILDING CODEC.I.P.CAST-IN-PLACE CONCRETE C.J.CONSTRUCTION JOINT ORCEILING JOINT ℄, CL.CENTERLINE CLG.CEILINGCLR.CLEAR C.M.U.CONCRETE MASONRY UNITCO.COMPANY COL.COLUMNCONC.CONCRETE CONST.CONSTRUCTION CONT.CONTINUOUSCRIP.CRIPPLE CTR.CENTERCU.FT.CUBIC FEET CU.IN.CUBIC INCHCU.YD.CUBIC YARD d b BAR DIAMETERDBL.DOUBLE DET.DETAIL DIA.DIAMETERDIAG.DIAGONAL DIM.DIMENSIOND.L.DEAD LOAD DN.DOWN DO.DITTO DWG.(S)DRAWING(S) (E)EXISTING EA.EACHEE.EACH END E.F. EACH FACE E.J.EXPANSION JOINT EL.ELEVATIONELEV.ELEVATOR EMBED.EMBEDMENTE.N. EDGE NAILING ENGR.ENGINEER ENGR'G ENGINEERINGEQ.EQUAL EQUIP.EQUIPMENTE.S.EACH SIDE ETC ET CETERAE.W.EACH WAY E-W EAST-WEST EXP.EXPANSIONEXT.EXTERIOR F.D.FLOOR DRAIN FOUND.FOUNDATION F.F.FINISH FLOORF.G.FINISH GRADE FIN.FINISHF.J.FLOOR JOIST F.L.G.FLANGEFL.FLOOR F.O.FACE OF F.O.C.FACE OF CONCRETE F.O.M.FACE OF MASONRY F.O.S.FACE OF STUDF.P.FULL PENETRATION F.O.F.FEET OR FOOTFT.FOOTING GA.GAUGEGAL.GALVANIZED G.B.GRADE BEAMGLBGLU-LAM BEAM GYP. BD.GYPSUM BOARD (H)HIGH HDR.HEADERHGR.HANGER H.R.HIP RAFTER HB.HIP BEAMHORIZ.HORIZONTALH.S.B.HIGH STRENGTH BOLTHT.HEIGHT I.C..O.INTERNATIONAL CONFERENCE OFBUILDING OFFICIALS I.R.INSIDE DIAMETER I.F. INSIDE FACEIN.INCH(ES)INFO.INFORMATION INT.INTERIOR JT.JOINTJST.JOIST K.KIP (1,000 LBS)K/FT, K/'KIPS PER FOOTKSIKIPS PER SQUARE INCH (L)LOW LG.LONGLIN.LINEARL.D.LIVE LOAD LONGIT.LONGITUDINAL L.S.LAG SCREWLT.WT.LIGHT WEIGHT M.B.MACHINE BOLT M.D.MID-DEPTHMATL.MATERIALMAX.MAXIMUMMECH.MECHANICALMEMB.MEMBRANE MFR.MANUFACTURERMIN.MINIMUMMISC.MISCELLANEOUSMTL.METAL (N)NEW N.A.NEUTRAL AXISNO., #NUMBERN-S NORTH-SOUTH N.T.S.NOT TO SCALE O.C., O/C ON CENTERO.D.OUTSIDE DIAMETERO.F.OUTSIDE FACE OPNG.OPENINGORIG.ORIGINAL PL.PLATE OF PROPERTY LINE PLY.WD.PLYWOODP.S.F., psf POUNDS PER SQUARE FOOTP.S.I., psi POUNDS PER SQUARE INCHP.T.POST-TENSIONING R.RADIUSRG.B.RIDGE BEAMR.B.ROOF BEAM RD.ROOF DRAIN REF.REFERENCEREINF.REINFORCE(D) / REINFORCINGREQD.REQUIRED R.R.ROOF RAFTER S.A.D.SEE ARCHITECTURAL DRAWINGSSCHED.SCHEDULE SEC.SECTION SHT.SHEETSIM.SIMILARS.J .SLAB JOINT S.O.G.SLAB-ON-GRADE SPESCL.SPECIFICATIONSSQ.SQUARESTAG.STAGGER(ED) STD.STANDARD STIFF STIFFENERST'L STEELSTR.STRAIGHT SYM.SYMMETRICAL (T)TOPT & B TOP AND BOTTOM T & G TONGUE AND GROOVE THK.THICKNESST.B.TRUSS JOISTT.O.C.TOP OF CONCRETE T.O.F.TOP OF FOOTING T.O.S.TOP OF SLAB(STEEL)TS STRUCTURAL TUBETRANS.TRANSVERSE TYP.TYPICAL U.B.C.UNIFORM BUILDING CODEU.N.O.UNLESS NOTED OTHERWISE VERT.VERTICALV.R.VALLEY RAFTERVARI.VARIOUS W/WITH WD WOODW/O WITHOUTW.J.WALL JOINTW.P.M.WATERPROOF MEMBRANE WT.WEIGHTW.W.F WELDED WIRE FABRIC APPROVAL STAMP WOOD FRAMES 1.ALL WORK SHALL CONFORM TO THE LABC 2023. 2.THE FOLLOWING NOTES AND ALL OTHER TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS NOTED OTHERWISE. 3.STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. 4.FRAMING CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE FRAMED SIMILAR TO THE DETAILS SHOWN FOR THE RESPECTIVE MATERIALS. 5.PROVIDE OPENINGS AND SUPPORTS FOR MECHANICALS EQUIPMENT, DUCTS, PIPING, VENTS AND ETC., AS REQUIRED. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL OPENINGS AND EQUIPMENT WHICH ARE NOT SHOWN ON STRUCTURAL DRAWINGS. ALL SUSPENDED EQUIPMENT TO BE PROVIDED WITH APPROVED ALL BRACING. 6.CONTRACTOR MUST CLARIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE COMMENCING WORK. ARCHITECT SHALL BE INFORMED AND NOTIFIED ANY TYPE OF DISCREPANCIES. 7.NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER THESE GENERAL NOTES. 8.DESIGN MATERIALS, EQUIPMENT, AND PRODUCTS OTHER THAN THOSE DESCRIBED BELOW OR INDICATED ON THE DRAWINGS MAY BE CONSIDERED FOR USE. PROVIDED PRIOR TO APPROVAL IS OBTAINED FROM THE OWNER, ARCHITECT/ENGINEER, AND THE APPLICABLE GOVERNING CODE AUTHORITY. 9.CONTINUOUS INSPECTION BY A CITY LICENSED DEPUTY INSPECTOR IS REQUIRED FOR ALL STRUCTURAL CONNECTIONS, FOOTINGS, GRADE BEAMS, AND RETAINING WALLS DURING INSTALLATION. 10.DESIGN CRITERIA ROOF LIVE LOADS : 20 psf ROOF DEAD LOADS : 20 psf(5 psf SOLAR PANEL INCLUDED) WIND DESIGN DATA BASIC WIND SPEED : 110 mph WIND IMPORTANCE FACTOR : 1.0 WIND EXPOSURE EACH DIRECTION : B INTERNAL PRESSURE COEFFICIENT : ±0.18 COMPONENTS AND CLADDING EARTHQUAKE DESIGN DATA SEISMIC IMPORTANCE FACTOR (I) : 1.0 RISK CATEGORY : II MAPPED SPECTRAL RESPONSE ACCELERATIONS Ss : 1.937g S1 : 0.687g SITE CLASS : D SPECTRAL RESPONSE COEFFICIENTS SDS : 1.550g SD1 : 0.779g SEISMIC DESIGN CATEGORY : D SEISMIC FORCE RESISTING SYSTEM LIGHT-FRAMED WALL SHEATHED WITH WOOD STRUCTURAL PANEL : R=6.5 DESIGN BASE SHEAR Cs = 0.310 BUILDING WEIGHT(lb) : lb DESIGN BASE SHEAR(lb) : lb EQUIVALENT LATERAL FORCE PROCEDURE REDUNDANCY FACTOR USED : 1.0 GENERAL NOTES Signature Code Program Committee 1-3: Structural Observation STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER PROJECT ADDRESS: Description of Work: Owner:Architect:Engineer: STRUCTURAL OBSERVATION (only checked items are required) Firm or Individual to be responsible for the Structural Observation: Name:Phone: ( )Calif. Registration: FOUNDATION WALL FRAME DIAPHRAGM Footing, Stem Walls, Piers Concrete DECLARATION BY OWNER I, the Owner of the project, declare that the above listed firm or individual is hired by me to be the Structural Observer. Signature License No.Date Date Mat Foundation Caisson, Piles, Grade Beams Stepp'g/ Retain'g Foundation, Hillside Special Anchors Others: Masonry Wood Others: Steel Moment Frame Steel Braced Frame Concrete Moment Frame Masonry Wall Frame Others: Concrete Others: Steel Deck Wood I, the Architect or Engineer of record for the project, declare that the above listed firm or individual is DECLARATION BY ARCHITECT OR ENGINEER OF RECORD(required if the Structural Observer isdifferent from the Architect or Engineer of Record) designated by me to be responsible for the Structural Observation. PERMIT APPL. NO.:501 S 1ST AVE. ARCADIA, CA 91006 JUNHO HWANG HWANG STRUCTURAL ENGINEERS INC.213 268-0935 SE-5592 STRUCTURAL OBSERVATION REPORT FORM - 1.CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTIONS" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE LADBS INSPECTORS AND OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC. 1704.1 2.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, CONCRETE STRENGTH f'c > 2500 psi, HIGH STRENGTH BOLTING, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, PRE-STRESSED CONCRETE, HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES. (1704 & CHAPTERS 19, 21, AND 22) 3.FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. (2304.12.1.4) 4.WELDING : FIELD WELDING TO BE DONE BY WELDERS CERTIFIED BY THE LADBS FOR (STRUCTURAL STEEL) (REINFORCING STEEL) (LIGHT GAUGE STEEL). CONTINUOUS INSPECTION BY DEPUTY INSPECTOR IS REQUIRED. -CONTINUOUS INSPECTION IS REQUIRED IN ACCORDANCE WITH TABLE 1704.3. -PERIODIC SPECIAL INSPECTION IS REQUIRED IN ACCORDANCE WITH SECTION 1704.3 AND TABLE 1704.3. 5.SHOP WELDS MUST BE PERFORMED IN A LADBS LICENSED FABRICATOR'S SHOP. 6.LADBS LICENSED FABRICATOR IS REQUIRED FOR (TRUSSES), (STRUCTURAL STEEL), 7.GLULAM BEAMS MUST BE FABRICATED IN THE LADBS LICENSED SHOP. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER T 5-A, 2018 NDS SUPP. 8.PROVIDE LEAD HOLE 40% - 70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK PORTION. 2018 NDS. 9.PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTION SHEATHING IS 4 INCHES ON CENTER OR LESS. (1705.12.2) 10.THE SPECIAL INSPECTOR MUST BE CERTIFIED BY THE LADBS, DEVELOPMENT SERVICES, IN THE CATEGORY OF WORK REQUIRED TO HAVE SPECIAL INSPECTION. 11.A COPY OF THE LOS ANGELES RESEARCH REPORT AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. 12.PROVIDE SPECIAL INSPECTION FOR THE EPOXY BOLTS. STATEMENT OF SPECIAL INSPECTIONS - SE-5592 - 1.ALL CONSTRUCTION SHALL COMPLY WITH THE WFPP. 2.ALL LUMBER TO BE STRESS GRADE, DOUGLAS FIR LARCH(DF), AS SHOWN BELOW PLANS PER NDS 2018 UNLESS OTHER WISE INDICATE ON A. JOISTS AND RAFTER : DF #2 GRADE B. 2"-4" BEAM : DF #1 GRADE : DF #2 GRADE FOR HEADER C. 5"x5" LARGER BEAM : DF #1 GRADE D. STUDS : DF #2 GRADE E. POST AND COLUMN : DF #1 GRADE 3.MOISTURE CONTENT IN USE WILL BE A MAXIMUM OF 19%. 4.DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS, UNLESS OTHERWISE NOTED, AND ALSO NAILED TOGETHER WITH 16d NAILS @9" O.C.. 5.UNLESS OTHERWISE NOTED ALL NAILING SHALL CONFORM TO THE NAILING SCHEDULE REQUIRED BY THE LOCAL DEPARTMENT OF THE BUILDING AND SAFETY. 6.CROSS BRIDGE FLOOR JOISTS AT 8'-0" MAXIMUM INTERVALS, MORE THAN 8" DEEP. 7.UNLESS OTHERWISE INDICATED, RAFTERS AND JOIST SHALL BE SPLICED AT SUPPORTS WITH A MINIMUM OF 4" OF LAP AND 4-16d NAILS. 8.TOP PLATE OF ALL STUD WALLS SHALL BE 2 PIECES OF 2x PLATES. SPLICES TO LAP 4'-0" MINIMUM AND BE NAILED WITH 12-16d NAILS MINIMUM EACH SIDE OF JOINT UNO. 9.PROVIDE SOLID 2x BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS. BLOCKING SHALL BE ONE PIECE AND THE FULL DEPTH OF THE JOIST OR RAFTER. 10.ALL BOLTS SHALL BE RE-TIGHTENED PRIOR TO THE APPLICATION OF SHEATHING, PLASTER ETC.. 11.EACH SHEET OF PLYWOOD SHALL BE IDENTIFIED BY A REGISTERED STAMP OR BRAND OF THE DOUGLAS FIR PLYWOOD ASSOCIATION. 12.WOOD STRUCTURAL PANELS SHALL COMPLY WITH U.S. PRODUCT STANDARDS FOR ITS TYPE IN PS 1 OR PS 2 AND BE CLASSIFIED AS EXPOSURE 1. AS A MINIMUM ALL WOOD STRUCTURAL PANELS SHALL BE APA RATED SHEATHING UNLESS NOTED OTHERWISE ON PLANS AND DETAILS. 13.ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED DOUGLAS FIR. 14.STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, ETC. UNLESS SPECIFICALLY DETAILED. 15.SHEATHING AND SHEAR WALLS SHALL BE INSPECTED AND APPROVED PRIOR TO COVERING. 16.BORED HOLES SHALL NOT BE LOCATED AT THE SAME SECTION OF STUD AS A CUT OR NOTCH. 17.HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHERS; AND HOLD-DOWN SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR TO COVERING THE WALL FRAMING. CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE STEEL PLATE WASHERS ON THE POST ON THE OPPOSITE SIDE OF THE ANCHORAGE DEVICE. PLATE SIZE SHALL BE A MINIMUM OF 0.299 INCH BY 3 INCHES BY 3 INCHES. 18.ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. 19.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 20.BOLT HOLES IN WOOD SHALL BE 1/32" TO 1/16" LARGER THAN THE NOMINAL BOLT DIAMETER. ALL BOLTS SHALL HAVE STANDARD CUT WASHER UNDER HEAD AND NUT UNLESS OTHERWISE NOTED. INSPECTOR TO VERIFY. 21.HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE TO FOUNDATION INSPECTION. 22.FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. LARR# / ESR#DETAIL -SIMPSON STRONG-TIE(A SERIES, A34, A35, LTP4, LTP5, FC, HH, L, LS AND Z STRUCTURAL ANGLES, CLIPS AND PLATES FOR WOOD FRAMING #25716 -SIMPSON STRAP (CMST, MST, HST AND LSTA) ESR-3096, ESR-2105 -SIMPSON HOLD-DOWN (HDU, HDQ8, HHDQ AND PHD) ESR-2330 -SIMPSON CCQ & ECCQ ESR-2604 -SIMPSON SET-3G EPOXY ESR-4057 A L L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F F T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E H W A N G S T R U C T U R A L E N G I N E E R S I N C . C O P Y R I G H T A L L R I G H T S R E S E R V E D . S200 FOUNDATION PLAN 02 DRAWN BY LAST REVISED DATE PROJECT NO. SHEET TITLE DRAWING NO. SHEET:OF: [25-05033] Engineer Seal: Project : 04 - - 2025/05/22 R E R LR S G A E F G E L N O G A W E HDOETS AHN A J T U T E T I UC L I F R O S T U F R No. 5592 Exp.06-30-25 CA IOSSENPRO N N I IA E R N 2 4 5 0 W M a i n S t . Alhambra, CA 91801 j u n o @ h w a n g s e .c o m T e l . 2 1 3 ) 2 6 8 -0 9 3 5 StructuralEngineers In c . Revisions DESCRIPTIONNO. 50 1 S 1 s t A v e . M e d i c a l O f f i c e R e m o d e l 50 1 S 1 s t A v e . Ar c a d i a , C A 9 1 0 0 6 SHEET NOTES DESCRIPTION PLAN LEGEND SYMBOL 3x FRAMING MEMBERS AT SILL PLATE AND BEHIND INDICATES SHEAR WALL. SEE SHEAR WALL SCHEDULE. VERTICAL OR HORIZONTAL PANEL EDGES W/ MIN.1/2" EDGE NAIL DISTANCE. 1.SEE SHEET S100 MATERIAL SPECIFICATIONS & FOUNDATION NOTES. 2.ALLOWABLE SOILS BEARING PRESSURE IS 1500 psf. 3.SEE S100 CONCRETE FOR ALL CONCRETE COMPRESSIVE STRENGTH. 4.ALL REINFORCING STEEL STRENGTH fy = 60ksi (GRADE 60) 5.ALL ANCHOR BOLTS TO BE 5/8"Ø A.B.x12" LONG 9" EMBEDMENT @48" O.C. U.N.O. SQUARE WASHER 3"x3"x1/4" SHALL BE USED WITH ALL ANCHOR BOLTS. U.N.O. 6.ANCHOR BOLT SCHEDULE AND SHEAR WALL FRAMES SEE SHEAR WALL SCHEDULE. 7.FOUNDATION SILLS SHALL BE PRESSURE TREATED OR FOUNDATION GRADE REDWOOD. 8.HOLD-DOWN HARDWARE MUST BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION. 9.HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING REQUIRE APPROVED PLATE WASHER: AND HOLD-DOWNS SHALL BE TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING. 10.PROVIDE 10d BOUNDARY NAILS AT THE PERIMETER OF BUILDING. 11.ALL STRUCTURAL STUDS TO BE 2x6 @16"O.C. FOR EXTERIOR WALL & 2x4 @16"O.C. FOR INTERIOR WALL. 12.ALL NON BEARING PARTITIONS. SEE DETAIL 6/S300. 13.PRIOR TO REQUESTING A BUILDING DEPARTMENT FOUNDATION INSPECTION, THE SOILS ENGINEER/GEOTECHNICAL CONSULTANT SHALL INSPECT AND APPROVE THE FOUNDATION EXCAVATIONS. WOOD POST HOLD-DOWN TYPE. SIMPSON HOLD-DOWN HDU2 U.N.O. SEE DETAIL 1/S300. HOLES SHALL BE 1/16" OVERSIZED AT THE CONNECTOR OF THE HOLD-DOWN TO POST WHICH SHALL BE VERIFIED AT THE JOB SITE BY THE INSPECTOR. SCALE : 1/4"=1'-0" FOUNDATION PLAN 01 N INDICATES BOUNDARY SIZE. SHEAR WALL INFO. SEE SHEAR WALL SCHEDULE 1/S300 A 4x4#1 HDU# 0'-0"SHEAR WALL LENGTH INFO. SHEAR WALL SCHEDULE FLOOR TO FLOOR CONCRETE SILL ATTACHMENT @12" O.C. TABLE 4.2A> @10" O.C. @8" O.C. @6" O.C. 3/8"Ø LAG-SCREWMIN. 3" PENET.BOTH SIDE A MI N . 2 " P E N E T R A T I O N @2" O.C. STAG. 5/ 8 " Ø A . B . SIMPSONA35 TIEOR LTP5 @6" O.C. BOTH SIDE @8" O.C. BOTH SIDE @10" O.C. @32" O.C. @24" O.C. @18" O.C. @12" O.C. @12" O.C. @9" O.C. @6" O.C. @2" O.C. STAG. @2 1/2" O.C. STAG. @3" O.C. STAG. @8" O.C. @5" O.C. @4" O.C. 1/ 4 " Ø L A G - S C R E W ALLOW.SHEAR(PLF) 340 510 665 870 1020 1330 1740BOTH SIDE@2/12 BOTH SIDE @3/12 BOTH SIDE @4/12 @6/12 @4/12 @3/12 @2/12 W/ 1 0 d C O M M O N N A I L S 15 / 3 2 " A P A S T R U C T U R A L - 1 ( O R O S B E Q . ) MATERIAL / DESCRIPTIONTYPE B C D E F G BO T H S I D E BO T H S I D E BO T H S I D E <AWC-SDPWS-2015. ** NOTE. ** a.3x FRAMING MEMBERS AT THE SILL PLATE AND ALL PANEL BOUNDARY MEMBERS. b.MIN. 1/2" EDGE NAIL DISTANCE AT PANEL END AND EDGE. c.NAILS SHALL BE STAGGERED WHERE NAILS ARE SPACED 2" O.C. d.SQUARE PLATE WASHERS SHALL BE USED WITH ALL ANCHOR BOLT. (TYP. ALL SHEAR WALL) 5/8"Ø BOLT - MIN. 3"x3"x1/4" (2x4) MIN. 3"x4 1/2"x1/4" (2x6) e.10d COMMON NAILS SHOULD BE WITH FULL HEADS. f.ALLOWABLE SHEAR VALUES ARE PERMITTED TO BE INCREASED 40 PERCENT FOR WIND DESIGN. (2306.3) g.1/4"Ø & 3/8"Ø LAG SCREW SHALL BE INSTALLED WITH STAGGERED. INDICATES (E)FOOTING. APPROVAL STAMP A B C 1 2 3 4 5 (E)1'-0" (E ) 1 ' - 0 " (E)1'-0" (E ) 1 ' - 0 " (E ) 1 ' - 0 " (E)1'-0" (E)CONC. SLAB ON GRADE (E)CONC. SLAB ON GRADE INDICATES (N)2x WOOD STUD WALL. 8'- 0 " CHD U 8 4x 6 # 1 3 S300TYP. * EXISTING MEMBERS AND THEIR DIRECTIONS SHALL BE VERIFIED WITH THE STRUCTURAL PLAN BEFORE CONSTRUCTION. EXISTING FOUNDATION CAN STAY AS IS IF LARGER THAN PLAN. A L L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F F T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E H W A N G S T R U C T U R A L E N G I N E E R S I N C . C O P Y R I G H T A L L R I G H T S R E S E R V E D . S201 03 DRAWN BY LAST REVISED DATE PROJECT NO. SHEET TITLE DRAWING NO. SHEET:OF: [25-05033] Engineer Seal: Project : 04 - - 2025/05/22 R E R LR S G A E F G E L N O G A W E HDOETS AHN A J T U T E T I UC L I F R O S T U F R No. 5592 Exp.06-30-25 CA IOSSENPRO N N I IA E R N 2 4 5 0 W M a i n S t . Alhambra, CA 91801 j u n o @ h w a n g s e .c o m T e l . 2 1 3 ) 2 6 8 -0 9 3 5 StructuralEngineers In c . Revisions DESCRIPTIONNO. 50 1 S 1 s t A v e . M e d i c a l O f f i c e R e m o d e l 50 1 S 1 s t A v e . Ar c a d i a , C A 9 1 0 0 6 1ST. FLOOR WALLS & ROOF FRAMING PLANSCALE : 1/4"=1'-0" 1ST. FLOOR WALLS & ROOF FRAMING PLAN 01 N 3x FRAMING MEMBERS AT SILL PLATE AND BEHIND INDICATES SHEAR WALL. SEE SHEAR WALL SCHEDULE. VERTICAL OR HORIZONTAL PANEL EDGES W/ MIN.1/2" EDGE NAIL DISTANCE. 1.SEE SHEET S100 FOR MATERIAL SPECIFICATION & ROOF FRAMING NOTES. 2.ALL ROOF DIAPHRAGM TO BE 15/32" PLYWOOD (PANEL INDEX 32/16) "SHEATHING GRADES, C-C, C-D" PS1 OR PS2 FOR THE CURRENT PLYWOOD STANDARD" W/10d COMMON NAILS @6/6/12. BLOCKED. 3.INSTALL STRUCTURAL SHEATHING (PLYWOOD) IN ALL EXTERIOR WALLS. 4.PROVIDE 4x WIDTH OF BEAM POST OF EQUIVALENT MULTI STUDS UNDER THE ALL BEAMS. 5.FASTENERS FOR WOOD STRUCTURAL PANEL SHEATHING ON SHEAR WALLS AND DIAPHRAGMS SHALL BE COMMON NAILS WITH FULL HEADS UNLESS OTHERWISE APPROVED. 6.ALL STRUCTURAL STUDS TO BE 2x6 @16"O.C. FOR EXTERIOR WALL & 2x4 @16"O.C. FOR INTERIOR WALL. 7.ALL EXTERIOR & INTERIOR HEADERS. SEE SCHEDULE 2/S300. 8.ALL NON BEARING PARTITIONS. SEE DETAIL 6/S300. SHEET NOTES DESCRIPTION PLAN LEGEND SYMBOL INDICATES BOUNDARY SIZE. SHEAR WALL INFO. SEE SHEAR WALL SCHEDULE 1/S300 A SHEAR WALL LENGTH INFO. 4x4#1 - 0'-0" APPROVAL STAMP SHEAR WALL SCHEDULE FLOOR TO FLOOR CONCRETE SILL ATTACHMENT @12" O.C. TABLE 4.2A> @10" O.C. @8" O.C. @6" O.C. 3/8"Ø LAG-SCREWMIN. 3" PENET.BOTH SIDE A MI N . 2 " P E N E T R A T I O N @2" O.C. STAG. 5/ 8 " Ø A . B . SIMPSONA35 TIEOR LTP5 @6" O.C. BOTH SIDE @8" O.C. BOTH SIDE@10" O.C. @32" O.C. @24" O.C. @18" O.C. @12" O.C. @12" O.C. @9" O.C. @6" O.C. @2" O.C. STAG. @2 1/2" O.C. STAG. @3" O.C. STAG. @8" O.C. @5" O.C. @4" O.C. 1/ 4 " Ø L A G - S C R E W ALLOW.SHEAR(PLF) 340 510 665 870 1020 1330 1740BOTH SIDE@2/12 BOTH SIDE @3/12 BOTH SIDE@4/12 @6/12 @4/12 @3/12 @2/12 W/ 1 0 d C O M M O N N A I L S 15 / 3 2 " A P A S T R U C T U R A L - 1 ( O R O S B E Q . ) MATERIAL / DESCRIPTIONTYPE B C D E F G BO T H S I D E BO T H S I D E BO T H S I D E <AWC-SDPWS-2015. ** NOTE. ** a.3x FRAMING MEMBERS AT THE SILL PLATE AND ALL PANEL BOUNDARY MEMBERS. b.MIN. 1/2" EDGE NAIL DISTANCE AT PANEL END AND EDGE. c.NAILS SHALL BE STAGGERED WHERE NAILS ARE SPACED 2" O.C. d.SQUARE PLATE WASHERS SHALL BE USED WITH ALL ANCHOR BOLT. (TYP. ALL SHEAR WALL) 5/8"Ø BOLT - MIN. 3"x3"x1/4" (2x4) MIN. 3"x4 1/2"x1/4" (2x6) e.10d COMMON NAILS SHOULD BE WITH FULL HEADS. f.ALLOWABLE SHEAR VALUES ARE PERMITTED TO BE INCREASED 40 PERCENT FOR WIND DESIGN. (2306.3) g.1/4"Ø & 3/8"Ø LAG SCREW SHALL BE INSTALLED WITH STAGGERED. A B C 1 2 3 4 5 (E)HDR (E)HDR (E)HDR (E)HDR (E)HDR (E)HDR (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E)2x R.R. (E)2x R.R. (E ) 2 x R . R . (E ) 2 x R . R . INDICATES (N)2x WOOD STUD WALL. HD R 4x 6 # 2 HD R 1 4x 8 # 1 HD R 1 4x 8 # 1 HD R 4x 6 # 2 HD R 4x 6 # 2 HDR 4x6 #2 HDR 4x6 #2 (E)2x C.J. (E)2x C.J. (E)2x C.J. 8'- 0 " C - 4x 6 # 1 4 S300TYP. TY P . 2/S 3 0 0 TY P . 2/S 3 0 0 TY P . 2/S 3 0 0 * EXISTING MEMBERS AND THEIR DIRECTIONS SHALL BE VERIFIED WITH THE STRUCTURAL PLAN BEFORE CONSTRUCTION. S300 04A L L D R A W I N G S A N D W R I T T E N M A T E R I A L A P P E A R I N G H E R E I N C O N S T I T U T E T H E O R I G I N A L A N D U N P U B L I S H E D W O R K O F F T H E S A M E M A Y N O T B E D U P L I C A T E D , U S E D O R D I S C L O S E D W I T H O U T T H E W R I T T E N C O N S E N T O F T H E H W A N G S T R U C T U R A L E N G I N E E R S I N C . C O P Y R I G H T A L L R I G H T S R E S E R V E D . DRAWN BY LAST REVISED DATE PROJECT NO. SHEET TITLE DRAWING NO. SHEET:OF: [25-05033] Engineer Seal: 50 1 S 1 s t A v e . M e d i c a l O f f i c e R e m o d e l Project : 04 - - 50 1 S 1 s t A v e . Ar c a d i a , C A 9 1 0 0 6 2025/05/22 R E R LR S G A E F G E L N O G A W E HDOETS AHN A J T U T E T I UC L I F R O S T U F R No. 5592 Exp.06-30-25 C A IOSSENPRO N N I IA E R N 2 4 5 0 W M a i n S t . Alhambra, CA 91801 j u n o @ h w a n g s e .c o m T e l . 2 1 3 ) 2 6 8 -0 9 3 5 StructuralEngineer s I nc. Revisions DESCRIPTIONNO. SHEAR WALLSEE PLAN B.N.TYP. WD. POSTSEE SCHED. SEE SCHEDULE HOLDOWN ANCHORSIMPSON HDU - THREADED ROD W/ 5/8"Ø A.B.3x TREATED PL. SEE SHEAR WALL SCHEDULE 6" M I N . EM B E D . SE E S C H E D . W/5/8"Ø A.B. (E)2x TREATED PL. @48" O.C. B.N. TYP. (E)FOOTING INTO 3/4"Ø HOLE W/ SET-3G EPOXY (ESR-4057) INTO 3/4"Ø HOLE FOR 5/8"Ø 7/8"Ø HOLE FOR 3/4"Ø 1"Ø HOLE FOR 7/8"Ø 1 1/8"Ø HOLE FOR 1"Ø W/ SET-3G EPOXY (E)CONC. SLABON GRADE (E)S.O.G. FOOTING SHEAR WALL LENGTH *. MIN WOOD POST SIZE HAS BEEN DESIGNED TO 11' OF UNBRACED COLUMN HEIGHT. *. HDU14 REQUIRES HEAVY HEX ANCHOR NUT. HDU4 HDU2 HDU5 HDU8 HDU11 HDU14 2-HDU11 SIMPSON 5/8"Ø 5/8"Ø 5/8"Ø 7/8"Ø 1"Ø 1"Ø 1"Ø A.B. 4x4 #1 4x4 #1 4x4 #1 4x6 #1 6x6 #1 6x6 #1 MIN.* WOOD POST PSL3.5x5.25 2.0E (10)-1/4x2.5 (6)-1/4x2.5 (14)-1/4x2.5 (20)-1/4x2.5 (30)-1/4x2.5 (36)-1/4x2.5 (30)-1/4x2.5 SDS SCREWS 3x3x1/4" 3x3x1/4" 3x3x1/4" 3x3x5/16" 3.5x3.5x3/8" 3.5x3.5x3/8" 3.5x3.5x3/8" WASHER 9" 9" 9" 9" 9" 9" 9" NEW 6" 9" EXIT. EMBEDMENT 6" EDGE DIST. A.B. SCHEDULE 4x6 #1 6"6" 6"6" 6" 10"6" 12"8" 12"8" SHEAR WALL LENGTH WD. STUDSSEE PLAN SIMPSON A35 ORSIMPSON LTP5SEE SCHED. 2x R.R.SEE PLAN 2x STUD WOOD HDR.SEE PLAN WD. POSTSEE SCHED. 2x DBLTOP PLATE (2)-16d TOE NAILS DET. SEE2 - B.N.TYP. APPROVAL STAMP 1SCALE : N.T.S. TYP. HOLDOWN ANCHOR DETAIL ROOF HEADER SCHEDULE OPENING WIDTH "W"x4 STUDS x6 STUDS HEADER UP TO 6'-0"4x6 #2 6x6 #2 FLOOR UP TO 8'-0"4x8 #2 6x8 #2 UP TO 10'-0"4x10 #2 6x10 #1 UP TO 5'-0"4x8 #2 6x8 #2 UP TO 6'-0"4x10 #2 6x8 #2 UP TO 7'-0"4x12 #2 6x10 #2 UP TO 8'-0"4x12 #1 6x12 #2 UP TO 10'-0"PSL 3.5x9.25 2.0E 6x12 #1 SCALE : N.T.S. TYP. HEADER DETAIL @SHEAR WALL LINE 2 4-10d TOE NAILSTYP. ADD. 2x TRIMMER WHERE "W" IS 6'-0" (1)-2x STUD (1)-2x TRIMMER (1)-2x STUD ADD. 2x STUDWHERE OPENING WIDTH "W" 6'-0" HEADER DBL. TOP PLATE 3x BLOCKING (ADD. ONLY @SHEAR WALL LINE)SIMPSON ST6236 WD. STUDSSEE PLAN "W" SEE SHEAR WALL SCHED. 2x OR 3x SILL PLATE ADD. 2x STUDWHERE OPENING WIDTH "W" 6'-0" SEE SCHEDULE (4)-16d TOE NAIL@ EACH END W/ 5/8"Ø A.B. x6" EMB. (E)2 OR 3x TREATED PL. SEE SHEAR WALL SCHED. SHEAR WALL SEE PLAN 6" SEE FDN. PLAN INTO 3/4"Ø HOLEW/SET-3G EPOXY (E)CONT. FOOTING SEE PLAN(E)WD. STUDS ON GRADE(E)CONC. SLAB B.N. (ESR-4057) 3SCALE : N.T.S. INT. WD. SHEAR WALL TO (E)FT'G CONNE. SEE PLAN DETAILS & SECTION SCALE : N.T.S. TYP. INT. SHEAR WALL CONNEC. (TOP LEVEL) WD. POST OR SIMPSON DBL. TOP PLATE SIMPSON WD. HDR. SEE PLAN (2)-2x STUD SEE PLAN WD. POST OR(2)-2x STUD SEE PLAN SCALE : N.T.S. TYP. HEADER TO POST CONNECTION 5 OPENING 3 ' - 0 " "HH4,HH6" "HH4,HH6" PERPENDICULAR SIMPSON A35SEE SCHED. SIMPSON A35SEE SCHED. B.N.(E)2x R.R.SEE PLAN E.N. (E)OR(N) WD. STUDSSEE PLAN (E)OR(N) WD. STUDSSEE PLAN B.N.(E)2x R.R. "DBL" JOISTS (4)-8d NAILS @48"O.C. UNDER THE WALL E.N. 2x BLOCKING SEE PLAN PARALLEL (3)-16d 4"4" (E)2x C.J. SEE PLAN (E)2x C.J. SEE PLAN SEE PLAN SHEAR WALL (E)2x C.J.SEE PLAN(E)2x C.J. SEE PLAN W/(2)-16d @16"O.C. 2x LEDGER SEE PLAN SHEAR WALL 4 SCALE : N.T.S. TYP. ALL NON BEARING WALL CONNEC.6 (E)2x R.R. SEE PLAN 2x4 STUDS@16"O.C. 1/ 2 " GA P 2x BLOCKING B.N. 1/ 2 " GA P(E)2x R.R. SEE PLAN 2x4 STUDS@16"O.C.SIMPSON STC @16" O.C.@BOTH SIDE @48" O.C. (ER-280) ON GRADE(E)CONC. SLAB 2x4 STUDS @16"O.C. 2x TREATED PL. x2" PENETRATION W/ 1/4"Ø SHOT PIN @16"O.C. Project Name Designed By Drawing No SCALE Sheet Revision Description By Date of Project No Issued Date Rev. Description 50 1 S . 1 s t A V E . M E D I C A L O F F I C E R E M O D E L 50 1 S . 1 s t A V E . , A R C A D I A , C A 9 1 0 0 6 501 S. 1st AVE. MEDICAL OFFICE REMODEL 25-2138 Drawn By 08.25.25 IY SC A+K DESIGN GROUP 13949 Ramona Ave. #d Chino, CA 91710 (626) 695-9836 www.akintl.com DESIGN GROUP ELECTRICAL GENERAL NOTES & SYMBOLS E0.01 AS NOTED Project Name Designed By Drawing No SCALE Sheet Revision Description By Date of Project No Issued Date Rev. Description 50 1 S . 1 s t A V E . M E D I C A L O F F I C E R E M O D E L 50 1 S . 1 s t A V E . , A R C A D I A , C A 9 1 0 0 6 501 S. 1st AVE. MEDICAL OFFICE REMODEL 25-2138 Drawn By 08.25.25 IY SC A+K DESIGN GROUP 13949 Ramona Ave. #d Chino, CA 91710 (626) 695-9836 www.akintl.com DESIGN GROUP TITLE 24 E0.02 AS NOTED Project Name Designed By Drawing No SCALE Sheet Revision Description By Date of Project No Issued Date Rev. Description 50 1 S . 1 s t A V E . M E D I C A L O F F I C E R E M O D E L 50 1 S . 1 s t A V E . , A R C A D I A , C A 9 1 0 0 6 501 S. 1st AVE. MEDICAL OFFICE REMODEL 25-2138 Drawn By 08.25.25 IY SC A+K DESIGN GROUP 13949 Ramona Ave. #d Chino, CA 91710 (626) 695-9836 www.akintl.com DESIGN GROUP NORTH DEMOLITION FLOOR PLAN E1.00 AS NOTED EXAM #1 FOYER RESTROOM WAITING CORRIDOR #1 EXAM #2 EXAM #3 OFFICE #1 EXAM #4 EXAM #6 OFFICE #2 KITCHEN EXAM #5 CORRIDOR #3 HALLWAY STORAGE #2 RECEPTION CORRIDOR #2 EXAM #7 STORAGE #1 EXAM #1 FOYER RESTROOM WAITING CORRIDOR #1 EXAM #2 EXAM #3 OFFICE #1 EXAM #4 EXAM #6 EXAM #7 OFFICE #2 KITCHEN EXAM #5 CORRIDOR #2 CORRIDOR #3 HALLWAY STORAGE #2 RECEPTION STORAGE #1 Project Name Designed By Drawing No SCALE Sheet Revision Description By Date of Project No Issued Date Rev. Description 50 1 S . 1 s t A V E . M E D I C A L O F F I C E R E M O D E L 50 1 S . 1 s t A V E . , A R C A D I A , C A 9 1 0 0 6 501 S. 1st AVE. MEDICAL OFFICE REMODEL 25-2138 Drawn By 08.25.25 IY SC A+K DESIGN GROUP 13949 Ramona Ave. #d Chino, CA 91710 (626) 695-9836 www.akintl.com DESIGN GROUP NORTH LIGHTING AND POWER FLOOR PLANS E1.01 AS NOTED NORTH Project : TI 25-05033 Address : 501 S 1st Ave. Arcadia, CA HWANG Structural Engineers Inc.E-mail) mail@hwangse.com 2450 W Main St. Alhambra, CA 91801 May, 2025 TI N L RO G LA WHEDROETSAHN A J T U T S GER I TUC IL F R A O S E TU F R No. 5592 Exp.06-30-25 CA IOSSENPROF NE G I NIA EER N Design Criteria Building Code LACBC 2023, CBC 2022 Project Address 501 S 1st Ave. Arcadia, CA Latitude Longitude Decimal Project Type Office Seismic Force Resisting System Bearing Wall System ASCE 7-16, Table 12.2-1 Special reinforced masonry shear walls R =5.0 Response Modification Coefficient USE Ω o =2.5 System Overstrength Factor Cd =3.5 Deflection Amplification Factor Material Concrete F'c =2500 psi for Slab-on Grade F'c =2500 psi for Foundation Reinforcing Steel ASTM A615 GR60 & GR40 Foundation System Allowable Soil Bearing Pressure Soils Report by F p =1500 psf for Isolation Pad & Continuous psf increases for each 1ft wide and in depth psf for Maximum μ =for Friction Passive earth pressure F p =psf psf Maximum Retaining walls lb/ft^3 cantilevered lb/ft^3 Restrained at-rest 34.1343 -118.0285 Design Criteria Design Load (Gravity Load) Vertical Load Roof DL Asphalt shingle 5.0 Live load reduction CBC 2022 Section 1607.10 Framing 2.7 General Sheathing 2.0 L = L0 (0.25 + 15/(KLL*AT)1/2 )EQ. 16-23 Ceiling 2.5 where, Misc 2.8 L = reduced design live load 15.0 L0 = unreduced design live load(Table 4-1) Future solar panel 5.0 KLL = live load element factor(Table 4-2) LL 20.0 AT = tributary area KLL*AT > 400 ft2 Reduction in roof L r = L 0 R 1 R 2 EQ. 16-26~32 where, R1 =1 for At ≤ 200 ft2 Exterior Wall 20.0 1.2 - 0.001 At for 200 ft2 <At < 600 ft2 0.6 for At ≥ 600 ft2 **R2 =1 for F ≤ 4 DL Dead Load 1.2 - 0.05 F for 4 < F < 12 LL Live Load 0.6 for F ≥ 12 F=number of inches of rise per ft Minimum roof live load shall be 12psf CBC 2022, Table 1607.10.1 Table 4-2 Live load element factor, KLL Element KLL Interior columns 4 Exterior columns without cantilever slabs 4 Edge columns with cantilever slabs 3 Corner columns with cantilever slabs 2 Edge beams without cantilever slabs 2 Interior beams 2 All other members not identified 1 including Edge beams with cantilever slabs Gravity Load Load Combination Load Combinations CBC 2022, Section 1605 Strength Design or Load and Resistance Factor Design CBC 2022, Section 1605.2 1.1.4(D + F)EQ. 16-1 2.1.2(D+F) + 1.6(L+H) + 0.5(L r or S or R)EQ. 16-2 3.1.2(D+F) + 1.6(Lr or S or R) + 1.6H + (f 1 L or 0.5W)f1 =1 for floors in places of public assembly,EQ. 16-3 4.1.2(D+F) + 1.0W + f1 L + 1.6H + 0.5(Lr or S or R) for live loads in excess of 100 psf EQ. 16-4 5.1.2(D+F) + 1.0E + 1.6H + f 1 L + f2 S 0.5 for other live loads EQ. 16-5 6.0.9D + 1.6W + 1.6H f2 =0.7 for roof configurations that do not shed EQ. 16-6 7.0.9(D+F) + 1.0E + 1.6H show off the structure, and EQ. 16-7 0.2 for other roof configurations Allowable Stress Design 1.D + F EQ. 16-8 2.D + H + F + L EQ. 16-9 3.D + H + F + (L r or S or R)EQ. 16-10 4.D + H + F + 0.75(L ) + 0.75(Lr or S or R)EQ. 16-11 5.D + H + F + (0.6W or 0.7E)EQ. 16-12 6.D + H + F + 0.75(0.6W) + 0.75L + 0.75(L r or S or R)EQ. 16-13 7.D + H + F + 0.75(0.7E) + 0.75L + 0.75 S EQ. 16-14 8.0.6D + 0.6W + H EQ. 16-15 9.0.6(D+F) + 0.7E + H EQ. 16-16 Seismic Load Effects and Combinations ASCE 7-16, Section 12.4 E = Eh + E v ASCE 7-16, EQ. 12.4-1 E = Eh - E v Use in Load Combination 7 or 8 ASCE 7-16, EQ. 12.4-2 Eh = ρQE Ev = 0.2S DS D Zero for determining demand on soils for foundation design Load Combination with EQ for Strength Design 5.(1.2 + 0.2SDS)D + ρQE + L + 0.2S for LL < = 100 psf, Use 0.5 L (except in garages or public assembly area) Use 1.51 D + #####QE +1.0 L 7.(0.9 - 0.2SDS)D + ρQE + 1.6H if H counter acts E do not include it Use 0.59 D + #####QE Load Combination with EQ for Allowable Stress Design 5.(1.0 + 0.14S DS )D + H + F + 0.7ρQ E Use 1.22 D + #####QE 6.(1.0 + 0.105SDS)D + H + F + 0.525ρQE + 0.75L + 0.75(Lr or S or R) Use 1.16 D + #####QE +0.75 L 8.(0.6 - 0.14S DS )D + 0.7ρQ E + H Use 0.38 D + #####QE Notation D Dead Load E Combined effect of horizontal and vertical EQ induced as defined in ASCE 7, Sec. 12.4.2 Em Maximum seismic load horizontal and vertical seismic forces as set forth in ASCE 7, Sec. 12.4.3 F Load due to fluids with well-defined pressures and maximum heights Fa Flood load H Load due to lateral earth pressures, ground water pressure or pressure of bulk materials L Live load, except roof live load, including any permitted live load reduction Lr Roof live load including any permitted live load reduction R Rain load S Snow load T Self-straining forces arising from contraction or expansion resulting from temperature change, shrinkage, moisture change, creep in component metarials, movement due to differential settlement or combinations thereof W Load due to wind pressure Multiple Simple Beam LIC# : KW-06015972, Build:20.25.05.07 HWANG Structural Engineers Inc.(c) ENERCALC, LLC 1982-2025 Project File: [25-05033] 501 S 1st Ave_Arcadia.ec6 Project Title:Engineer:Project ID:Project Descr: Roof HeadersDescription : BEAM Size :4x8, Sawn, Fully BracedUsing Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2018, CBC 2019 Douglas Fir-Larch No.11,350.01,350.0 925.0625.0 1,600.0580.0170.0675.0 31.210Eminbend - xx ksi Wood Species :Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psiFc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf HDR1 Applied Loads Unif Load: D = 0.020, Lr = 0.020 k/ft, Trib= 12.0 ft .Design Summary Max fb/Fb Ratio =0.685 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 4.000 inft 96.85 psi Fb : Allowable :2,193.75 psi Right Support Fv : Allowable :Span # 1 Load Comb :+D+Lr212.50 psi fb : Actual : Max fv/FvRatio =0.456 : 1 0.000 ft 1,502.86 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max DeflectionsTransient Downward 0.125 in Transient Upward 0.000 in Total Downward 0.250 in Total Upward 0.000 in 0.96 0.960.96 0.96 Ratio 767 383Ratio LC: Lr Only LC: +D+Lr LC:LC: BEAM Size :4x6, Sawn, Fully BracedUsing Allowable Stress Design with ASCE 7-16 Load Combinations, Major Axis Bending Wood Beam Design : Calculations per NDS 2018, IBC 2018, CBC 2019 Douglas Fir-Larch No.2875.0875.0 600.0625.0 1,300.0470.0170.0425.0 31.210Eminbend - xx ksi Wood Species :Wood Grade :Fb - Tension psipsi Fv psiFb - Compr Ft psiFc - Prll psipsiFc - Perp Ebend- xx ksi Density pcf HDR Applied Loads Unif Load: D = 0.020, Lr = 0.020 k/ft, Trib= 12.0 ft .Design Summary Max fb/Fb Ratio =0.459 : 1 Max Reactions (k)HEWSLLr +D+LrLoad Comb : Span # 1 Left Support D in 2.000 inft 57.85 psi Fb : Allowable :1,421.88 psi Right Support Fv : Allowable :Span # 1 Load Comb :+D+Lr212.50 psi fb : Actual : Max fv/FvRatio =0.272 : 1 0.000 ft 652.85 psi at atfv : Actual : Ratio 9999 Ratio 9999 Max DeflectionsTransient Downward 0.022 in Transient Upward 0.000 in Total Downward 0.044 in Total Upward 0.000 in 0.48 0.480.48 0.48 Ratio 2178 1089Ratio LC: Lr Only LC: +D+Lr LC:LC: Design Load (Seismic Load) Lateral Load Design Load (Seismic Load) Seismic Base Shear Location Lat 34.1343 Long -118.0285 Building Usage Office Site Class D ASCE 7-16, Section 11.4.3 Response Modification Coefficient ASCE 7-16, Table 12.2-1 R =5 Site Specific Spectral Acceleration SEACO seismic design map Max.Ss, S1 provided from USGS Site Coefficients S s (0.2 sec)1.937 g F a 1.2 ASCE 7-16, Table 11.4-1 S 1 (1.0 sec)0.687 g F v 1.7 ASCE 7-16, Table 11.4-2 Ajusted MCE spectral response acceleration ASCE 7-16, EQ 11.4-1,2 S MS = F aS s 2.324 S M1 = FvS1 1.168 Design Spectral Response Acceleration Parameters ASCE 7-10, EQ 11.4-3,4 S DS = 2/3S MS 1.550 S D1 = 2/3SM1 0.779 Occupancy Category II CBC 2019, Table 1604.5 Importance Factor 1 ASCE 7-16, Section 11.5.1 Design Base Shear Determine the Structural Period Ct =0.020 ASCE 7-16, Table 12.8-2 h n = 10.0 ft x =0.75 ASCE 7-16, Table 12.8-2 Ta = Ct * (hn 0.112 sec Determine the Seismic Response Coefficient Cs On short period Occupancy Factor Use the smaller value of Value of SDS I or II III IV 0.310 SDS < 0.167 A A A 0.167 <SDS< 0.33 B B C 0.33 <SDS< 0.50 C C D 1.385 for T<TL 0.5 <SDS D D D On 1-S period Occupancy Factor Cs shall not be less than 0.01 Value of SDS I or II III IV Cs shall not be less than 0.5*S1/(R/I)SD1 < 0.067 A A A Design Value for Cs 0.067 <SD1< 0.133 B B C Cs = 0.310 0.133 <SD1< 0.20 C C D Design Base Shear 0.20 <SDS D D D V 1 = Cs *W 0.310 W Table 11.4-1 Site Coefficient, Fa Table 11.4-2 Site Coefficient, Fv For Allowable Stress Design >0.25 0.5 0.75 1 1.25 1.5 >0.1 0.2 0.3 0.4 0.5 0.6 V BASE = 0.7*V 1 0.217 W A 0.8 0.8 0.8 0.8 0.8 0.8 A 0.8 0.8 0.8 0.8 0.8 0.8 B 0.9 0.9 0.9 0.9 0.9 0.9 B 0.8 0.8 0.8 0.8 0.8 0.8 C 1.3 1.3 1.2 1.2 1.2 1.2 C 1.5 1.5 1.5 1.5 1.5 1.4 D 1.6 1.4 1.2 1.1 1 1 D 2.4 2.2 2 1.9 1.8 1.7 Seismic Design Category D E 2.4 1.7 1.3 Section 11.4.8 E 4.2 See Section 11.4.8 F See Section 11.4.8 F See Section 11.4.8 Values of approximate period parameters Ct and x Structure type x Steel moment-resisting frames 0.80 Concrete moment-resisting frames 0.90 Eccentrically braced steel frames 0.75 All other structural systems 0.750.02 0.03 0.016 0.028 Ct     DS S1 SC = =R I     D1S2 SC = =TR I Lateral Load Design Load (Seismic Load) Vertical Distribution of Seismic Force ASCE 7-16, Section 12.8.3 F x =Cvx V ASCE 7-16, EQ. 12.8-11 ASCE 7-16, EQ. 12.8-12 Cvx vertical distribution factor V total design lateral force or shear at the base of the structure wi and wx the portion of the total effective seismic weight of the structure(W) located Level i and x hi and hx the height from the base to Level i and x k an exponent related to the structure period 1 for Ta is less than 0.5 sec 2 for Ta is more than 2.5 sec k=1+(Ta-0.5)/2 for Ta between 0.5 and 2.5 sec k = V = W = Strength Design W = ASD V = W = Strength Design W = ASD Redundancy Factor ρ for Seismic Design Categories D through F ASCE 7-16, Section 12.3.4.2 For structures assigned to Seismic Design Category D, E, or F, ρ shall equal 1.3 unless one of the following two conditions is met, whereby ρ is permitted to be taken as 1.0 a) Each story resisting more than 35 percent of the base shear in the direction of interest shall comply with Table 12.3-3. b) Structures that are regular in plan at all levels provided that the seismic force-resisting systems consist of at least two bays of seismic force-resisting perimeter framing on each side of the structure in each orthogonal direction at each story resisting more than 35% of the base shear. The number of bays for a shear wall shall be calculated as the length of shear wall divided by the story height or two times the length of shear wall divided by the story height for lightframed construction. ρ =1 1.000 0.310 22.31 0.217 15.62 0.310 22.31 0.217 15.62 Accu. FxLevel x hx h x h x k Area DL (kips) w x w x h x k w x hx k Fx Σwih i k (kips)(ft) (ft)ft 2 (psf) Roof 9 9 9.0 2400 (kips) psf 6.5130 72.0 648 1.00 72.0 648 1.00 6.51 15.6 15.6  k x xvxn k i i i=1 w hC = w h Vertical Distribution Roof Grid A C Seismic load 6.51 6.51 6.51 Depth 62 62 62 Length 16.5 6 16.5 Shear force 3329 3329 1211 1211 3329 3329 SUM Design Shear 3329 3329 Diap. force 54 54 20 20 54 54 Governed by seismic No change No change No change 2nd floor Grid A E Seismic load 18.50 18.50 18.50 Depth 6 6 6 Length 16.5 6 16.5 Shear force 916 916 333 333 916 916 SUM 2498 Design Shear 916 916 Diap. force 15 15 5 5 15 15 Bldg 43291249 D 4540 15737 B 1249 D 4540 B.1 15737 La t e r a l A n a l y s i s Wood Wall Design Roof If the shear force is from Strength Level N-S Direction 0.7=Strength to Allowable LARR #25720, #25713 Wall Wall V H d H/d WSP R Vi w Mo Ma T V s SW HD Strap Line No. (#) (ft) (ft)1.25-0.125H/dd/Sd ratio*V (#/ft) (ft-#) #/ft B.1 1 4540 9 8.00 1.125 1.1 1.00 4540 200 40856 2452 4801 567 C HDU8 2-MST-48 8.00 if the H/d ratios greater than 2:1, but not exceeding 3.5:1, are permitted SDPWS 2015 4.3.4 the nominal shear capacity shall be multipled by the Aspect Ratio Factor (WSP)=1.25-0.125h/b For Hold-down M o = Use 0.7Q E ASCE 7-16, Section 12.4 1.0 M a = Use (0.6 - 0.14SDS)D =0.38 See Load combination #8 La t e r a l A n a l y s i s Shear Wall Schedule Shear Wall Schedule CBC 2022, LABC 2023 - Table 2306.4.1 Hold-down loads LARR # 25720 0.75x simpson allowable tension loads Model No.SDS A.B Min wood All. Tension Member (in) 1/4 x2.5 5/8 3 3075 2306 1/4 x2.5 5/8 3 4565 3424 1/4 x2.5 5/8 3 5645 4234 1/4 x2.5 7/8 3.5 6970 5228 4.5 7870 5903 1/4 x2.5 1 5.5 9535 7151 7.25 11175 8381 1/4 x2.5 1 5.5 14375 10781 Strap 0.75x simpson allowable tension loads LARR # 25713 Model No.Allowable tension loads(lbs.) Nails Bolts CD=1.33 CD=1.6 Nails Bolts Nails Bolts 3 1/2 3 1/2 HST HST2 6-5/8" 4385 5260 HST5 12-5/8" 8840 10605 HST3 6-3/4" 6450 7740 HST6 12-5/8" 12700 15240 16" clear span floor to floor Nails Nails Nails Nails MST MST27 30-16d 3195 2396 MST37 42-16d 3195 2396 MST48 50-16d 4765 3574 MST60 64-16d 6490 4868 MST72 64-16d 6490 4868 MST 18" clear span floor to floor Nails Nails Nails Nails MST37 20-16d 2465 1849 MST48 32-16d 3960 2970 MST60 46-16d 6235 4676 MST72 62-16d 6490 4868 HDU14 HDU8 HDU5 HDU4 HDU2 HDU11 Foundation design Continuous Footing Exterior Grid Roof Floor Pt Max.Pt = 380 lb/ft DL 20 0 psf DL Tri. Length = 9 ft.From Roof 180 lb/ft LL 20 0 LL Tri. Length = 0 ft.From Floor 20 psf DL Tri. Height = 10 ft.From Wall 0 LL Pt lb/ft Allowable soil bearing pressure psf Allowable soil bearing pressure = psf 12" Width x 24" Depth Cont. Footing Interior Grid Roof Floor Pt Max.Pt = 440 lb/ft DL 20 0 psf DL Tri. Length = 12 ft.From Roof 240 lb/ft LL 20 0 LL Tri. Length = 0 ft.From Floor 20 psf DL Tri. Height = 10 ft.From Wall 0 LL Pt lb/ft Allowable soil bearing pressure psf Allowable soil bearing pressure = psf 12" Width x 24" Depth Cont. Footing Allowable Force Check 12" Width x 24" Depth :Pallow = {(4" + 24" x 2) / 12" x 12" / 12"} x 1500 psf = 4.33 x 1500 = lbs 1500 6500.0 0.37 ft 680 1500 1500 = 0.45 ft1500 Width Lreq = = 560 = Width Lreq = =