HomeMy WebLinkAbout38 E Huntington Dr - 2026 - Dental OfficeH
U
N
T
I
N
G
T
O
N
D
R
.
CL
(E
)
S
I
D
E
W
A
L
K
PR
O
P
E
R
T
Y
L
I
N
E
-
5
0
.
0
0
'
(E
)
G
U
T
T
E
R
PLOT PLANN
PROPERTY LINE - 146.00'
(E) BUILDING
(NOT A PART)
(E) TREE
PROPERTY LINE - 146.00'
A
L
L
E
Y
(E) ACCESSIBLE
PATH OF TRAVEL
(E) TREE
(E)
SEWER
MANHOLE
PATH OF TRAVEL NOTE:
NO ABRUPT CHANGES IN ELEVATION ALONG THE
PATH OF TRAVEL SHOW. THE SLOPE AND
CROSS-SLOPE ALONG THE PATH OF TRAVEL SHALL
NOT EXCEED 5% AND 2% RESPECTIVELY.
INSPECTOR TO VERIFY.
ENTRY
(E) TRASH
ENCLOSURE
(E) PARKING
(1 ADA PARKING
SPOT PROPOSED
REF A1.2)
(E) 36"
BLOCK
WALL
1
4 5 6 7
(THIS SUITE IS PART OF
BUILDING & ON PROPERTY
BUT NOT WITHIN SCOPE,
883.7 SF)
AREA OF ALTERNATION
WITHIN EXISTING BUILDING
2,123.8 BLDG SF (E) STORM
MANHOLE
(E) STREET LIGHT
ACCESS
(E) FIRE
HYDRANT
(E) 36" BLOCK
WALL
(E) BUILDING
(NOT A PART)(E) PARKING
(NOT A PART OF)
(E) PARKING
(NOT A PART OF)
(E) PARKING
(NOT A PART OF)
(E) BUILDING
(NOT A PART)
(E) TREE
(E) TREE
(E) CROSS WALK
LIGHT
(E) CROSS WALK
(E) PALM
TREE
(THIS SUITE IS PART OF
BUILDING & ON PROPERTY
BUT NOT WITHIN SCOPE,
1740.4 SF)CL
(E) LANDSCAPING
(NO CHANGE)
(E) VESTUBULE
74.8 SF TO (N)
WAITING AREA
PR
O
P
E
R
T
Y
L
I
N
E
-
5
0
.
0
0
'
(E) ELEC
METERS
(N) MECH.
CLOSET
NEW MECHANICAL CLOSET NOTE:
SOUND NOT TO EXCEED 50db
2 3
COMPACT
SPACE
NOPA
R
K
I
N
G
(N) VAN
ACCESSIBLE
ADA PARKING
(N) ACCESSIBLE
PATH OF TRAVEL
FOR PROPOSED
VAN ADA PARKING
(E) TRUNCATED
DOMES
(N) VAN
ACCESSIBLE ADA
PARKING SYMBOL
ADA PARKING NOTES:
1. SUGGESTED SIGN LOCATION AT THE ENTRANCE TO
THE PARKING AREA FROM THE STREET REGARDING
UNAUTHORIZED VEHICLES SHALL NOT USE THE
DESIGNATED ACCESSIBLE PARKING SPACES.
SUGGESTED SIGN LOCATION "$250 MINIMUM FINE"
2. THE BOARDER OF THE ACCESS AISLE SHALL BE
PAINTED BLUE.
3.REFERENCE SHEET A9.1 FOR ADA PARKING DETAILS.
(N) TRUNCATED
DOMES 3'x4'
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
A1.1
PLOT PLAN, PROPERTY
INFO, NOTES
VICINITY MAP
PROPERTY INFORMATION
AREA TABULATIONS
SCOPE OF WORK
SHEET INDEX
CONSULTANTS
EXISTING FRONT STOREFRONT VIEW EXISTING REAR AND PARKING VIEW
L.A. ASSESSOR PARCEL MAP
DENTAL LETTER
ADDITIONAL NOTES:
7. THIS FACILITY IS NOT INTENDED TO BE AN OSHPD LICENSED CLINIC.
8. THIS IS NOT AN AMBULATORY CARE FACILITY THAT CAN RENDER
INDIVIDUALS INCAPABLE OF SELF-PRESERVATION.
11.NO MEDICAL GAS WILL BE USED AT THIS MEDICAL SURGERY OFFICE.
12.NO HAZARDOUS MATERIALS WILL BE STORED AND / OR USED
WITHIN THIS BUILDING, AS CONDITION OF OCCUPANCY.
H
U
N
T
I
N
G
T
O
N
D
R
.
CL
PR
O
P
E
R
T
Y
L
I
N
E
-
5
0
.
0
0
'
PROPERTY LINE - 146.00'
PROPERTY LINE - 146.00'
A
L
L
E
Y
(E) SEWER
MANHOLE
(E) TRASH
ENCLOSURE (TO
BE REMOVED &
REPLACED)
1 2
4 5 6 7
(THIS SUITE IS PART OF
BUILDING & ON PROPERTY
BUT NOT WITHIN SCOPE,
883.7 SF)
AREA OF ALTERNATION
WITHIN EXISTING BUILDING
2,123.8 BLDG SF
(E) 36"
BLOCK
WALL
(THIS SUITE IS PART OF
BUILDING & ON PROPERTY
BUT NOT WITHIN SCOPE,
1740.4 SF)
CL
(E) LANDSCAPING
(NO CHANGE)
PR
O
P
E
R
T
Y
L
I
N
E
-
5
0
.
0
0
'
(E) ELEC
METERS
EXISTING 74.8 SF
VESTIBULE SPACE IS BEING
ADDED TO EXTEND THE
PROPOSED WAITING AREA
(N) ADA VAN ACCESSIBLE
PARKING SPACE AT
REAR OF BUILDING IN
(E) PARKING LOT
(E) 36"
BLOCK
WALL
COMPACT
SPACE
(N) MECH.
CLOSET
3
N
OPA
R
K
I
N
G
PROPOSED SITE PLAN
N
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
A1.2
PLOT PLAN FRONT
VIEW PICTURES
PICTURE #1 PICTURE #2 PICTURE #3 PICTURE #4
A1.2
4
A1.2
3 SEE
PICTURE
NUMBER
A1.2
2
SEE
PICTURE
NUMBER
A1.2
2
SEE
PICTURE
NUMBER
(E) TRASH
ENCLOSURE
(TO REMAIN)
(E
)
5
4
x
5
4
W
I
N
D
O
W
TO
B
E
S
E
A
L
E
D
(E) 36"
(E) ELECTRICAL
METERS
(E) TRASH / (N) MECH. RM. PLAN
N
PROPERTY LINE
(N) 36"
(N) MECHANICAL
CLOSET
COMPRESSOR
W/H
(E) DOOR
DRAIN
A1.3
A
FRAMING,
FOUNDATION &
DETAILS REF S-2
STUCCO FINISH
(MATCH BLDG)
ASPHALT SHINGLE
ROOF, 2 x 6 R.R.
FRONT ELEVATION
36" METAL DOOR
FOR MECHANICAL CLOSET
ACCESS
SIDE ELEVATION
(E) TRASH / (N) MECH. CLOSET(N) MECHANICAL CLOSET
123
SECTION A
2 x 6 R.R.
@ 16" O.C.
4 x 6 HDR
2 x 4 STUDS
1/2" PLYWD
BOTH SIDES
STUCCO FINISH
BOTH SIDES
ASPHALT SHINGLES
CLASS "B", w/ 1/2"
PLYWD, #30 FELT
METAL FLASHING
(E) METAL DOOR(E) BLOCK WALL
A1.3
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
PROPOSED TRASH
ENCLOSURE PLAN
EXISTING TRASH ENCLOSURE AT REAR OF BUILDING
A1.4
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
APPLICATION FOR
HARDSHIP EXCEPTION
DR. GONZALES
A1.5
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
HEALTH DEPARTMENT
APPROVAL LETTER
A1.8
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
STORE FRONT DETAIL
A1.9
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
STORE FRONT DETAIL
EXISTING & DEMO FLOOR PLAN
N
(E) TRASH
ENCLOSURE
(E) 60x48
(E) SIDEWALK
3
8
H
U
N
T
I
N
G
T
O
N
D
R
.
(E) 60x48(E) 60x48
(E) 92x84
(E
)
5
4
x
5
4
℄
(E) RECEPTION(E) OFFICE
1
(E) COMP. &
COMM RM
(E) CONFERENCE ROOM
(E)
HALLWAY
(E) UNISEX
RESTROOM
(E) UNISEX
RESTROOM
(E) OPEN WORKSPACE
(E) UNISEX
RESTROOM
(E) CORRIDOR
(E) OFFICE
(E) OPEN WORKSPACE
(E) CORRIDOR
(E) LADDER
ROOF ACCESS
(E
)
3
6
"
(E
)
3
6
"
(E
)
3
6
"
(E
)
3
6
"
(E) 36"
(E
)
3
6
"
(E) 36"(E
)
3
6
"
(E
)
3
6
"
(E) 36"
(E) 36"
(E) 36"
(E) 36"
(E) 36"
(E
)
3
6
"
(E
)
5
4
x
5
4
(E
)
3
6
"
(E) 36"
(E)
3
6
"
(E
)
S
H
E
L
V
E
S
(E) STORAGE
(E) DOUBLE
HT RM
(E) DÉJÀ VU MED SPA
(NOT A PART OF)
(E) OFFICE
2
(E) OFFICE
3
(E) OFFICE
4
(E) MTL. DOOR &
GATE TO BE
REMOVED (SECURITY
ENTRANCE)
(E) GLASS ENTRY
DOORS & WINDOWS
TO BE REMOVED
(E) 48" LOW WALL
TO BE MODIFIED
FOR COUNTER USE
(REF A2.2 & A6.1)
(E) PARKING
(REF A1.1)
(E) PRIVATE
GATED
ENTRANCE
(E
)
S
T
O
R
E
F
R
O
N
T
A
G
E
PR
O
P
E
R
T
Y
L
I
N
E
5
0
'
EXISTING 74.8 SF
VESTIBULE SPACE
BETWEEN
STOREFRONT
AND SECURITY
ENTRANCE
(E) ELEC.
METERS
(E) BRICK
VENEER
(TO REMAIN)
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
A2.1
EXISTING &
DEMO PLAN
PROPOSED FLOOR PLAN
N
(E) SIDEWALK
(N) WAITING AREA(N)
RECEPTION
(N) OP #1
(N) OP #4
(N) OFFICE
(E) LADDER
ROOF ACCESS
(E) 60x48(E) 60x48(E) 60x48
(E) 92x84
(E
)
3
6
"
(E) 36"
(E
)
3
6
"
(E) 36"(E
)
3
6
"
(E
)
3
6
"
(N) 36"
(E) 36"
(E) 36"
(E
)
3
6
"
(E
)
5
4
x
5
4
(N) OP #2
(E)
3
6
"
(N)
STERILIZATION
AREA
(E) UNISEX
RESTROOM
(E
)
S
H
E
L
V
E
S
(E) STORAGE
3
8
H
U
N
T
I
N
G
T
O
N
D
R
.
℄
(E) DÉJÀ VU MED SPA
(NOT A PART OF)
(N) 36"
(N) 36"
(E) COMP. &
COMM RM
(N) DOORS & WINDOWS
FRONT ENTRY
(REF A1.8)
(E) 48" LOW WALL TO BE
MODIFIED FOR COUNTER
USE SEE DET 1 A6.1
(E) UNISEX
RESTROOM
(N) OP #3
(E)
HALLWAY(E) PARKING
(REF A1.1)
(E) EMPTY SUITE
(NOT A PART OF)
(E) PRIVATE
GATED
ENTRANCE
(N) 36"
(N) CONSULTING (N) OFFICE MANAGER
EXISTING 74.8
SF VESTIBULE
SPACE IS BEING
ADDED TO
EXTEND THE
PROPOSED
WAITING AREA
PR
O
P
E
R
T
Y
L
I
N
E
5
0
'
(E) ADA RESTROOM
SEE A6.1 FOR ADA
DETAILS
(E
)
S
T
O
R
E
F
R
O
N
T
A
G
E
MO
N
I
T
O
R
(N) CT
(E) ELEC.
METERS
(N)
COUNTER
101
102
103104
105106107
108
109
110
111
112 113
114
115
116
(E) CORRIDOR
A4.1
1
(E) BRICK
VENEER
(TO REMAIN)
(E) TRASH
ENCLOSURE
(N) 36"
(N) MECH.
CLOSET
A7.1
1
A7.1
2
101
102
103
104
105
106
107
108
109
A4.2
A
A2.2
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
PROPOSED PLAN
EXIT
S
N
REFLECTIVE CEILING PLAN
3
8
H
U
N
T
I
N
G
T
O
N
D
R
.
℄
PROPERTY LINE 146'
PROPERTY LINE 146'
(E)
(N)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)(E)(E)
(E)
(E)
(E)
(N)
(N)(N)(N)
(N)
(E)(E)(E)(E)
GFI
(E)
(E
)
E
L
E
C
T
R
I
C
A
L
ME
T
E
R
S
(E)
SS
S S
S
S(E)
(E)
(E)
S
EXIT
S
(N)
(E)
S S
(E)(E)
S(E)S
(E)EX
I
T
EX
I
T
S SS(E)(E)(E)
EX
I
T
NOTE:
NO CHANGE TO
EXISTING CEILING AND
NO CHANGE TO
EXISTING SUSPENDED
T-BAR
EXISTING STUCCO CEILING TO BE
REFINISHED TO SMOOTH TEXTURE,
NO T-BAR IS BEING PROPOSED
(E)(E)
(E)(E)
NEW NON BEARING WALL 1SCALE
3/4" = 1'-0"
A4.1
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
REFLECTIVE CEILING
PLAN
SECTION DETAIL AT ENTRANCE ASCALE
3/4" = 1'-0"
A4.2
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
SECTION DETAIL
#
3
8
H
U
N
T
I
N
G
T
O
N
D
R
.
℄
ENTRY
19
30
101
102
103104
105106107
108
109
110
111
112 113
114
115
116
TR
A
V
E
L
DI
S
T
A
N
C
E
29
'
-
5
"
TRAV
E
L
DISTA
N
C
E
13'-9"
TR
A
V
E
L
DI
S
T
A
N
C
E
43
'
-
6
"
TR
A
V
E
L
DI
S
T
A
N
C
E
55
'
-
2
"
TR
A
V
E
L
DI
S
T
A
N
C
E
56
'
-
0
"
TR
A
V
E
L
DI
S
T
A
N
C
E
51
'
-
8
"
TR
A
V
E
L
DI
S
T
A
N
C
E
34
'
-
1
0
"
TR
A
V
E
L
DI
S
T
A
N
C
E
31
'
-
2
"
TRAVEL
DISTANCE
72'-11"
TRAVEL
DISTANCE
69'-6"
TRAVEL
DISTANCE 60'-8"
TRAVEL
DISTANCE
73'-6"
TRAVEL
DISTANCE 20'-6"
EXIT #2
EGRESS SIZING CALCULATION
19 OCCUPANTS X 0.2 =
3.8 LINEAR INCHES REQUIRED
EXISTING = 36 INCHES PROVIDED
EXIT #1
EGRESS SIZING CALCULATION
30 OCCUPANTS X 0.2 =
6 LINEAR INCHES REQUIRED
NEW = 72 INCHES PROVIDED
(E) TRASH
ENCLOSURE
(N) MECH.
CLOSET
N
LIFE SAFETY FLOOR PLAN
A5.1
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
LIFE SAFETY FLOOR
PLAN, OCCUPANT
LOAD
A6.1
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
ADA NOTES
RECEPTION COUNTER WALL ADA DETAIL 1
(N) 36"
30"x48"
CLEAR SPACE
17
"
-
1
8
"
FLUSH
ACTIVATOR
ON WIDE
SIDE
60" MIN.
DIA. CLR.
24"
MIN.
CE
N
T
E
R
L
I
N
E
TO
F
I
X
T
U
R
E
18
"
M
I
N
7'-1"
7'
-
3
"
ENLARGED FLOOR PLAN
(E) ADA RESTROOM
1
NOTE: SEE SHEET A6.1
FOR ACCESSIBILITY
DETAILS
60x56 CLEARANCE
PER CBC 11B-604.3.1
(E) 36"
(E
)
S
H
E
L
V
E
S
ENLARGED FLOOR PLAN
(E) HALLWAY SINK
2
30"x48"
CLEAR
SPACE
SINK DIAGRAM
KNEES CLEARANCE
2B
ST
R
I
K
E
S
I
D
E
E
D
G
E
O
F
DO
O
R
/
O
P
E
N
I
N
G
F
R
A
M
E
1'-0"
WHITE INTERNATIONAL
SYMBOL OF ACCESSIBILITY
BLUE BACKGROUND COLOR 15090 OF
FEDERAL STANDARD NUMBER 595B
BUILDING ENTRY SIGNAGE
(SECURE TO STOREFRONT GLASS
W/ ADHESIVE). PROVIDE PLASTIC
BACKING ON OTHER SIDE OF
GLASS FOR COVERAGE. ADHESIVE
SHALL BE COMPATIBLE W/ GLASS
APPLICATION.
6"
6"
60
"
A.
F
.
F
.
FIGURE 11B-703.7.2.1
INTERNATIONAL SYMBOL OF ACCESSIBILITY
CL
BUILDING ENTRY SIGN
3
11B-703.2 RAISED CHARACTERS.
RAISED CHARACTERS SHALL COMPLY WITH SECTION 11B-703.2 AND SHALL BE DUPLICATED IN BRAILLE
COMPLYING WITH SECTION 11B-703.3. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH
SECTION 11B-703.4.
11B-703.2.1 DEPTH
RAISED CHARACTERS SHALL BE 1/32 INCH (0.8 mm) MINIMUM ABOVE THEIR BACKGROUND.
11B-703.2.2 CASE
CHARACTERS SHALL BE UPPERCASE.
11B-703.2.3 STYLE
CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY
DECORATIVE, OR OF OTHER UNUSUAL FORMS.
11B-703.2.5 CHARACTER HEIGHT
CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8
INCH MINIMUM AND 2 INCHES MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I".
11B-703.3 BRAILLE.
BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS 11B-703.3 AND 11B-703.4.
11B-703.3.1 DIMENSIONS AND CAPITALIZATION
BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11B-703.3.1
11B-703.4 INSTALLATION HEIGHT AND LOCATION
SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH SECTION 11B-703.4.
11B-703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND.
TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR
OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60
INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE
OF THE HIGHEST LINE OF RAISED CHARACTERS.
11B-703.4.2 LOCATION
WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR
AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF,
THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDE AT DOUBLE
DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND
DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT
SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS
CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES
MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE
ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. WHERE
PERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMS AND SPACES THEY SHALL BE
LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT
IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM
OR SPACE.
11B-703.5 VISUAL CHARACTERS SHALL COMPLY WITH SECTION 11B-703.5.
11B-703.5.1 FINISH AND CONTRAST
CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL
CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR
DARK CHARACTERS ON A LIGHT BACKGROUND.
11B-703.6 PICTOGRAMS
PICTOGRAMS SHALL COMPLY WITH SECTION 11B-703.6.
11B-703.6.1 PICTOGRAM FIELD
PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL
NOT BE LOCATED IN THE PICTOGRAM FIELD.
TACTILE EXIT SIGN
EXIT
4"
4"
NOTES:
TACTILE EGRESS SIGNAGE (SECURE TO
STOREFRONT GLASS W/ ADHESIVE). PROVIDE
PLASTIC BACKING OVER OTHER SIDE OF GLASS FOR
COVERAGE. ADHESIVE SHALL BE COMPATIBLE w/
GLASS APPLICATION.
EXIT
60
"
M
A
X
.
RAISED GRADE 2 BRAILLE:
"EXIT".
A.
F
.
F
.
48
"
M
I
N
.
A.
F
.
F
.
BUILDING EXIT SIGN
4
EXIT ROUTE SIGN
5
9" MIN.
6"
M
I
N
.
2"
M
A
X
.
5/
8
"
M
I
N
.
1/
2
"
M
A
X
.
3/
8
"
M
I
N
.
NOTES:
1. RAISED CHARACTERS SHALL COMPLY WITH CBC 11B-703.2 AND SHALL BE DUPLICATED
IN BRAILLE.
2. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH CBC 11B-703.3.
3. SIGNS WITH TACTILE CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH
CBC 11B-703.4
4. ALL VISUAL CHARACTERS SHALL COMPLY WITH CBC 11B-703.5
5. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH, AND SHALL
CONTRAST WITH THEIR BACKGROUND PER CBC 11B-703.5.
6. EDGES OF SIGN SHALL COMPLY WITH CBC 11B-703.7.2.6.4.
RAISED GRADE 2 BRAILLE
CHARACTERS REFER
TO NOTE #1
ROUTE
EXIT
2"
M
A
X
.
5/
8
"
M
I
N
.
1/
2
"
M
A
X
.
3/
8
"
M
I
N
.
"EXIT ROUTE"
A7.1
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
ADA NOTES
DOOR SCHEDULE
NO.ROOM NAME SIZE
ENTRY 2 - 3'-0" x 7'-0"
THK.TYPE MAT'L
DOOR
FINISH
WAITING AREA
HDW.
SET.NO.MAT'L FINISH HEAD
FRAME
JAMB REMARKS
B A1.8 A1.8101
102 3'-0" x 7'-0"1-3/4"A PAINTED 2 PAINTED
#
UNISEX RESTROOM103 3'-0" x 7'-0"1-3/4"A PAINTED 1 HALLOW METAL
SOLID CORE
SOLID CORE PAINTED
104 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E)
105 OP #4 2 - 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E)
106 OFFICE 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E)
107 COMP & COMM RM 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E)
PRIVATE ENTRY 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E)(E)(E)108
PRIVATE GATE 3'-0" x 7'-0"109 (E)(E)(E)(E)(E)(E)
1 2
1 2
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
11
(E) LEVER TYPE
1, 4, 5, 9
1, 2, 3, 4, 5, 6, 8, 9
1, 2, 7
1, 4, 5, 7
1-3/4"GLASS PANE FACTORY PER MANUFACTURE
PUSH-PULL HALLOW METAL PAINTED
HALLOW METAL
REMARKS
DOOR HINGES: USE 3-1/2" SCREWS
(ALL HARDWARE TO BE STAINLESS STEEL)
SIGNAGE: "MEN" / "WOMEN" / "UNISEX"
ON TOILET ROOM DOOR
DOOR CLOSER: HEAVY DUTY - AMERICAN DEVICE
SERIES 6301 or LCN 4021
RESTROOMS THAT OPEN INTO HALLWAY OR
OPEN SPACE MUST BE COMPLETELY ENCLOSED
WITH SELF-CLOSING DOORS.
1
2
3
4
5
CLEAN, REPAIR AS REQUIRED
KICK PLATE, FULL WIDTH OF DOOR @ 10 INCH MIN HT.
AT BASE (36" HT. AT IMPACT DOOR)
PROVIDE ACCESSIBLE IDENTIFICATION SYMBOLS6
7
8
9
ALL WOOD DOORS TO BE PREFINISHED "STAINED AT
HOLLOW METAL DOOR FRAME TO BE BLACK
FACTORY". COLOR TO BE MATTE BLACK. G.C. TO INSTALL
10 EXTERIOR DOORS ARE SELF-CLOSING,
AND RODENT PROOFED
11 CRL ENTICE HP+ ENTRANCE FRONT DOOR SYSTEM, INSTALL
PER MANUFACTURE SPECIFICATIONS
12 DOORS AND GATES SERVING AN OCCUPANT LOAD OF 50
OR MORE SHALL SWING IN THE DIRECTION OF TRAVEL.
DOOR NOTES HARDWARE
UNISEX RESTROOM
MECHANICAL CLOSET 3'-0" x 7'-0"110 1, 4, 5, 10,1-3/4"SOLID CORE PAINTED PER MANFACTURE HALLOW METAL PAINTED
SET #1:PASSAGE DOOR - NON RATED
3 EA BUTT HINGES
1 SELF CLOSER
1 MORTISE LOCK
1 FLOOR STOP
2 KICK PLATE
SET #2:OFFICE - NON RATED
3 EA BUTT HINGES
1 MORTISE LOCK
1 FLOOR STOP
1 LEVER TYPE HANDLE
1 LEVER TYPE HANDLE
1.G.C. TO VERIFY THAT EXISTING DOORS TO REMAIN ARE IN GOOD
WORKING CONDITION.
2.ALL EXISTING DOORS TO REMAIN SHALL KEEP THE EXISTING
HARDWARE U.N.O. OR FOUND TO NOT FUNCTION PROPERLY.
G.C. TO CLEAN AND REPAIR HARDWARE TO AS-NEW CONDITION.
3.NEW BEST LOCK LEVER TYPE HARDWARE, FINISH TO MATCH EXISTING.
G.C. TO VERIFY IN FIELD.
4.EXIT DOORS SHALL BE OPERABLE FROM THE EGRESS SIDE WITHOUT
THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. CBC 1010.1.9
5.G.C. TO PROVIDE SIGNAGE WITH 1-INCH HIGH LETTERING ON MAIN EXIT /DOOR
"THIS DOOR TO REMAIN UN-LOCKED WHEN BUILDING IS OCCUPIED."
6.ALL FINISH HARDWARE SHALL COMPLY WITH ALL GOVERNING CODES
AND ACCESSIBILITY CODES. [CBC 11B-404.2.7 AND 11B-309.4]
7.ALL DOOR EDGES SHALL BE PRIMED AND PAINTED. VERIFY COLOR
WITH INTERIOR ELEVATIONS.
8.G.C. SHALL PROVIDE A FLOOR MOUNTED DOOR STOP FOR DOORS
THAT SWING AGAINST THE WALL.
9.ALL DOOR SILENCERS SHALL BE INSTALLED AFTER DOOR AND FRAME
HAVE RECEIVED FINAL PAINTED.
10. INSTALL CAULKING AROUND DOOR FRAME JAMBS, HEAD AND AT
BOTTOM OF FRAME.
11. DOOR OPENING FORCE: FIRE DOORS SHALL HAVE A MINIMUM
OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE
AUTHORITY. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN,
EXTERIOR OR INTERIOR HINGED DOORS WITH CLOSERS AND SLIDING
OR FOLDING DOORS, SHALL NOT EXCEED FIVE POUNDS (22.2 N)
MAXIMUM.
12. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON
DOORS AND GATES THAT ARE IN A PATH OF TRAVEL SHALL BE
OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST. (11B-309.4).
OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MINIMUM AND
44" MAXIMUM ABOVE THE FINISH FLOOR OR GROUND (11B-404.2.7)
13. ALL NEW DOORS MUST BE EQUIPPED WITH LEVEL TYPE HANDLE.
1
5/8"2"
5/8" MIN.
(TYP.)
PA
R
T
I
T
I
O
N
WI
D
T
H
1/
2
"
EA
C
H
S
I
D
E
2"
2"
5/8" TYPE "X" GYPSUM
BOARD EACH SIDE
HOLLOW
METAL FRAME
DOOR - PER
SCHEDULE
3" = 1'-0"
SCALE
2"2"
PARTITION
WIDTH
3" = 1'-0"
SCALE
5/8" TYPE "X" GYPSUM
BOARD EACH SIDE
EXTEND GYPSUM BOARD
INTO FRAME 5/8" MIN.
JAMB ANCHOR
HOLLOW METAL
FRAME
DOOR - PER SCHEDULE
STANDARD RABBET
2"
5/
8
"
5/
8
"
M
I
N
.
(T
Y
P
.
)
1/2" EA.
SIDE (TYP.)
2
INTERIOR DOOR HEAD
INTERIOR DOOR JAMB
1, 4, 5, 7
7
1, 4, 5, 7, 10
7, 13
PER
MANFAC.
PER
MANFAC.
14. LANDINGS OR FLOOR LEVEL AT DOORS SHALL NOT BE MORE THAN 1/2-INCH
BELOW THE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL
CHANGES GREATER THAN 1/4-INCH AT DOORWAYS SHALL BE BEVELED
WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS
HORIZONTAL. [CBC 11B-404.2.5]
15. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING
SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. [CBC 11 B-404.2.1 0]
16. PROVIDE A LEVEL LANDING ON EACH SIDE OF A DOOR EXTENDING 60" ON
DIRECTION OF DOOR SWING AND 48" IN OPPOSITE DIRECTION OF DOOR
SWING, MEASURED WITH DOOR CLOSED. [CBC 1 LB-404.2.4 AND TABLE 1
LB-404.2.4.1]
17. A LANDING SHALL EXTEND 24" PAST STRIKE SIDE OF EXTERIOR DOORS ON
PULL SIDE AND 18" MINIMUM PAST STRIKE EDGE OF INTERIOR DOORS.
PROVIDE 12" ON PUSH SIDE, IF THE DOOR HAS BOTH A LATCH AND A
CLOSER. [CBC TABLE 11 B-404.2.4.1]
13 HARDWARE LOCK AND LATCHING COMPLIANCE WITH
CBC 1010.2.4.
DOOR TYPES
TYPE - A
TEMPERED
GLASS DOOR
PER
SCHED.
PER
SCHED.
10" x WIDTH OF DOOR
STAINLESS STEEL
KICK PLATE WHERE
OCCUR, TYP.
MA
T
C
H
(
E
)
34
"
M
I
N
.
-
4
4
"
M
A
X
.
PE
R
S
C
H
E
D
U
L
E
TYPE - B
10
"
MA
T
C
H
(
E
)
34
"
M
I
N
.
-
4
4
"
M
A
X
.
PE
R
S
C
H
E
D
U
L
E
PER
MANFAC.
1 ADD 12 INCHES IF CLOSER AND LATCH ARE PROVIDED.
2 ADD 4 INCHES IF CLOSER AND LATCH ARE PROVIDED.
3 BEYOND HINGE SIDE.
4 ADD 4 INCHES IF CLOSER IS PROVIDED.
5 ADD 6 INCHES AT EXTERIOR SIDE OF EXTERIOR DOORS.
11B-404.1 GENERAL. DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 11B-404.
11B-404.2 MANUAL DOORS. MANUAL DOORS AND DOORWAYS, AND MANUAL GATES, INCLUDING TICKET GATES, SHALL COMPLY WITH SECTION 11B-404.2
11B-404.2.1 REVOLVING DOORS. MA
11B-404.2.1 REVOLVING DOORS, GATES, AND TURNSTILES. REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES SHALL NOT BE PART OF AN ACCESSIBLE ROUTE.
11B-404.2.2 DOUBLE-LEAF DOORS AND GATES. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH SECTIONS 11B-404.2.3 AND 11B-404.2.4.
11B-404.2.3 CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES (813 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE
MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR
OPENING OF 36 INCHES (914 MM) MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES (864 MM) ABOVE THE FINISH FLOOR
OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES (864 MM) AND 80 INCHES (2032 MM) ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4
INCHES (102 MM).
EXCEPTIONS:
1. IN ALTERATIONS, A PROJECTION OF 5/8 INCH (15.9 MM) MAXIMUM INTO THE REQUIRED CLEAR WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP.
2. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1981 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND.
3. DOORS, DOORWAYS, AND GATES NOT PROVIDING FULL USER PASSAGE SHALL PROVIDE A CLEAR WIDTH OF 20 INCHES (510 MM) MINIMUM.
11B-404.2.4 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH SECTION 11B-404.2.4. MANEUVERING CLEARANCES SHALL
EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE.
11B-404.2.4 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH SECTION 11B-404.2.4. MANEUVERING CLEARANCES SHALL
EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE.
11B-404.2.4.1 SWINGING DOORS AND GATES. SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.1.
11B-404.2.4.2 DOORWAYS WITHOUT DOORS OR GATES, SLIDING DOORS, AND FOLDING DOORS. DOORWAYS LESS THAN 36 INCHES (914 MM) WIDE WITHOUT DOORS OR GATES, SLIDING
DOORS, OR FOLDING DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.2.
11B-404.2.4.3 RECESSED DOORS AND GATES. MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES (457 MM) OF
THE LATCH SIDE AT AN INTERIOR DOORWAY, OR WITHIN 24 INCHES (610 MM) OF THE LATCH SIDE OF AN EXTERIOR DOORWAY, PROJECTS MORE THAN 8 INCHES (203 MM) BEYOND THE
FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE.
11B-404.2.4.4 FLOOR OR GROUND SURFACE. FLOOR OR GROUND SURFACE WITHIN REQUIRED MANEUVERING CLEARANCES SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL
ARE NOT PERMITTED.
EXCEPTIONS:
1. SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED.
2. CHANGES IN LEVEL AT THRESHOLDS COMPLYING WITH SECTION 11B-404.2.5 SHALL BE PERMITTED.
11B-404.2.5 THRESHOLDS. THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH (12.7 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL
COMPLY WITH SECTIONS 11B-302 AND 11B-303.
11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES. THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE 48 INCHES (1219 MM)
MINIMUM PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE.
MIN.
24"
MIN.
24"
MI
N
.
42
"
MI
N
.
48
"
MIN.
12"MI
N
.
48
"
MI
N
.
60
"
MIN.
18"
MIN.
36"
MI
N
.
60
"
APPROACH DIRECTION
FROM FRONT
FROM SIDE
FROM STOP/LATCH SIDE
MIN.
32"
MIN.
32"
48 INCHES
42 INCHES
42 INCHES
0 INCHES
0 INCHES
24 INCHES
PERPENDICULAR TO DOORWAY
PARALLEL TO DOORWAY
(BEYOND LATCH UNLESS
NOTED)
MINIMUM MANEUVERING CLEARANCES
MINIMUM MANEUVERING CLEARANCES AT MANUAL SWINGING
DOORS
TYPE OF USE
APPROACH
DIRECTION PERPENDICULAR TO DOORWAY
PARALLEL TO DOORWAY
(BEYOND LATCH UNLESS
NOTED)
DOOR
SIDE
FROM FRONT
FROM FRONT
FROM HINGE SIDE
FROM HINGE SIDE
FROM LATCH SIDE
FROM LATCH SIDE
PULL
PUSH
PULL
PUSH
PULL
PUSH
60 INCHES
48 INCHES
60 INCHES
44 INCHES
44 INCHES
60 INCHES
0 INCHES
18 INCHES
36 INCHES
22 INCHES
24 INCHES
24 INCHES
(a) FRONT APPROACH, PULL SIDE
(c) FRONT APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
(d) HINGE APPROACH, PULL SIDE
MIN.
22"
(f) HINGE APPROACH, PUSH SIDE
MI
N
.
60
"
(h) LATCH APPROACH, PULL SIDE
MI
N
.
44
"
(j) LATCH APPROACH, PUSH SIDE
TABLE 11B-404.2.4.2 - MANEUVERING CLEARANCES AT DOORWAYS WITHOUT
DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING
DOORS
TABLE 11B-404.2.4.1 - MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
3
1
4
2
1 DOORWAY WITH NO DOOR ONLY.
2 BEYOND POCKET/HINGE SIDE.
2
90°
FIGURE 11B-404.2.3
CLEAR WIDTH OF DOORWAYS
MIN.
32"
MIN.
36"
>2
4
"
(a) HINGED DOOR
(b) SLIDING DOOR
(c) FOLDING DOOR
(d) DOORWAYS WITHOUT
DOORS
FIGURE 11B-404.2.4.1
MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATES
MIN.
12"
MI
N
.
48
"
X>
8
"
X>
8
"
MI
N
.
48
"
18" MIN. AT INTERIOR
MI
N
.
60
"
X>
8
"
FIGURE 11B-404.2.4.3
MANEUVERING CLEARANCE AT RECESED DOORS AND GATES
(a) PULL SIDE
(b) PUSH SIDE (c) PUSH SIDE, DOOR PROVIDED
WITH BOTH CLOSER AND LATCH
MI
N
.
48
"
FIGURE 11B-404.2.6
DOORS IN SERIES AND GATES IN SERIES
(b)
(a)
5
FROM POCKET/HINGE SIDE 42 INCHES 22 INCHES
1
MI
N
.
48
"
(b) FRONT APPROACH, PUSH SIDE
MI
N
.
48
"
MIN.
22"
(g) HINGE APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
MIN.
24"MI
N
.
48
"
(k) LATCH APPROACH, PUSH SIDE,
DOOR PROVIDED WITH CLOSER
24" MIN. AT EXTERIOR
48
"
M
I
N
.
(c)
11B-404 DOOR AND DOORWAYS
(E) LEVER TYPE
(E) LEVER TYPE
(E) LEVER TYPE
(E) LEVER TYPE
(E) LEVER TYPE
A8.1
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
DOOR SCHEDULE,
HARDWARE NOTES &
DETAILS
A9.1
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
ADA PARKING NOTES
F1.1
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
FURNITURE SPECS
ADS DENTAL CHAIR PACKAGE
ELITE SERIES DENTAL
COMPRESSOR
ADP DENTAL COMPRESSOR
CT SCAN X-RAY DENTAL SPECIFICATIONS
SUGGESTED PARTITON
CGN 1
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
GREEN
NOTES
CGN 2
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
GREEN
NOTES
CGN 3
38
E
.
H
U
N
T
I
N
G
T
O
N
D
R
AR
C
A
D
I
A
,
C
A
9
1
0
0
6
Revisions:
This project is sold for use in the
construction of one t.i. only. Any
further use of this design without the
express permission of the designer is
prohibited.
These drawings have been prepared to
meet standards practices. However, local
variations may require changes. Likewise,
building code requirements vary with
location and change from time to time.
Before starting construction, the builder
must review and be responsible for all
details and dimensions, and insurance that
these plans meet all current govermental
requirements in your area.
RG Design &
Consulting
Ow
n
e
r
:
Sheet Contents:
T.
I
.
N
E
W
D
E
N
T
I
S
T
O
F
F
I
C
E
"S
E
D
A
T
I
O
N
A
N
D
I
M
P
L
A
N
T
D
E
N
T
I
S
T
S
"
Printed on:
Drawn by:
Pr
o
j
e
c
t
:
SHEET No.
rg-design1@att.net
Ramon A. Gallardo
122 N. CORDOVA ST.
ALHAMBRA, Ca. 91801
ph (626) 864-0927
fax (626) 570-4473
LO
Project No.:
2025-000
"CONTRACTOR TO VERIFY
DIMENSIONS PRIOR TO
CONSTRUCTION"
Written Dimensions Shall take
preference over scaled
dimensions and shall be
verified on the Job Site. Any
discrepancy shall be Brought
to the notice of RGD prior to
commencement of any work.
Dec 03, 2025
Ad
d
r
e
s
s
:
TR
G
O
N
Z
A
L
E
S
Engineer
GREEN
NOTES
REVISIONS BY
REVISIONS BY
REVISIONS BY
REVISIONS BY