Loading...
HomeMy WebLinkAbout38 E Huntington Dr - 2026 - Dental OfficeH U N T I N G T O N D R . CL (E ) S I D E W A L K PR O P E R T Y L I N E - 5 0 . 0 0 ' (E ) G U T T E R PLOT PLANN PROPERTY LINE - 146.00' (E) BUILDING (NOT A PART) (E) TREE PROPERTY LINE - 146.00' A L L E Y (E) ACCESSIBLE PATH OF TRAVEL (E) TREE (E) SEWER MANHOLE PATH OF TRAVEL NOTE: NO ABRUPT CHANGES IN ELEVATION ALONG THE PATH OF TRAVEL SHOW. THE SLOPE AND CROSS-SLOPE ALONG THE PATH OF TRAVEL SHALL NOT EXCEED 5% AND 2% RESPECTIVELY. INSPECTOR TO VERIFY. ENTRY (E) TRASH ENCLOSURE (E) PARKING (1 ADA PARKING SPOT PROPOSED REF A1.2) (E) 36" BLOCK WALL 1 4 5 6 7 (THIS SUITE IS PART OF BUILDING & ON PROPERTY BUT NOT WITHIN SCOPE, 883.7 SF) AREA OF ALTERNATION WITHIN EXISTING BUILDING 2,123.8 BLDG SF (E) STORM MANHOLE (E) STREET LIGHT ACCESS (E) FIRE HYDRANT (E) 36" BLOCK WALL (E) BUILDING (NOT A PART)(E) PARKING (NOT A PART OF) (E) PARKING (NOT A PART OF) (E) PARKING (NOT A PART OF) (E) BUILDING (NOT A PART) (E) TREE (E) TREE (E) CROSS WALK LIGHT (E) CROSS WALK (E) PALM TREE (THIS SUITE IS PART OF BUILDING & ON PROPERTY BUT NOT WITHIN SCOPE, 1740.4 SF)CL (E) LANDSCAPING (NO CHANGE) (E) VESTUBULE 74.8 SF TO (N) WAITING AREA PR O P E R T Y L I N E - 5 0 . 0 0 ' (E) ELEC METERS (N) MECH. CLOSET NEW MECHANICAL CLOSET NOTE: SOUND NOT TO EXCEED 50db 2 3 COMPACT SPACE NOPA R K I N G (N) VAN ACCESSIBLE ADA PARKING (N) ACCESSIBLE PATH OF TRAVEL FOR PROPOSED VAN ADA PARKING (E) TRUNCATED DOMES (N) VAN ACCESSIBLE ADA PARKING SYMBOL ADA PARKING NOTES: 1. SUGGESTED SIGN LOCATION AT THE ENTRANCE TO THE PARKING AREA FROM THE STREET REGARDING UNAUTHORIZED VEHICLES SHALL NOT USE THE DESIGNATED ACCESSIBLE PARKING SPACES. SUGGESTED SIGN LOCATION "$250 MINIMUM FINE" 2. THE BOARDER OF THE ACCESS AISLE SHALL BE PAINTED BLUE. 3.REFERENCE SHEET A9.1 FOR ADA PARKING DETAILS. (N) TRUNCATED DOMES 3'x4' 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer A1.1 PLOT PLAN, PROPERTY INFO, NOTES VICINITY MAP PROPERTY INFORMATION AREA TABULATIONS SCOPE OF WORK SHEET INDEX CONSULTANTS EXISTING FRONT STOREFRONT VIEW EXISTING REAR AND PARKING VIEW L.A. ASSESSOR PARCEL MAP DENTAL LETTER ADDITIONAL NOTES: 7. THIS FACILITY IS NOT INTENDED TO BE AN OSHPD LICENSED CLINIC. 8. THIS IS NOT AN AMBULATORY CARE FACILITY THAT CAN RENDER INDIVIDUALS INCAPABLE OF SELF-PRESERVATION. 11.NO MEDICAL GAS WILL BE USED AT THIS MEDICAL SURGERY OFFICE. 12.NO HAZARDOUS MATERIALS WILL BE STORED AND / OR USED WITHIN THIS BUILDING, AS CONDITION OF OCCUPANCY. H U N T I N G T O N D R . CL PR O P E R T Y L I N E - 5 0 . 0 0 ' PROPERTY LINE - 146.00' PROPERTY LINE - 146.00' A L L E Y (E) SEWER MANHOLE (E) TRASH ENCLOSURE (TO BE REMOVED & REPLACED) 1 2 4 5 6 7 (THIS SUITE IS PART OF BUILDING & ON PROPERTY BUT NOT WITHIN SCOPE, 883.7 SF) AREA OF ALTERNATION WITHIN EXISTING BUILDING 2,123.8 BLDG SF (E) 36" BLOCK WALL (THIS SUITE IS PART OF BUILDING & ON PROPERTY BUT NOT WITHIN SCOPE, 1740.4 SF) CL (E) LANDSCAPING (NO CHANGE) PR O P E R T Y L I N E - 5 0 . 0 0 ' (E) ELEC METERS EXISTING 74.8 SF VESTIBULE SPACE IS BEING ADDED TO EXTEND THE PROPOSED WAITING AREA (N) ADA VAN ACCESSIBLE PARKING SPACE AT REAR OF BUILDING IN (E) PARKING LOT (E) 36" BLOCK WALL COMPACT SPACE (N) MECH. CLOSET 3 N OPA R K I N G PROPOSED SITE PLAN N 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer A1.2 PLOT PLAN FRONT VIEW PICTURES PICTURE #1 PICTURE #2 PICTURE #3 PICTURE #4 A1.2 4 A1.2 3 SEE PICTURE NUMBER A1.2 2 SEE PICTURE NUMBER A1.2 2 SEE PICTURE NUMBER (E) TRASH ENCLOSURE (TO REMAIN) (E ) 5 4 x 5 4 W I N D O W TO B E S E A L E D (E) 36" (E) ELECTRICAL METERS (E) TRASH / (N) MECH. RM. PLAN N PROPERTY LINE (N) 36" (N) MECHANICAL CLOSET COMPRESSOR W/H (E) DOOR DRAIN A1.3 A FRAMING, FOUNDATION & DETAILS REF S-2 STUCCO FINISH (MATCH BLDG) ASPHALT SHINGLE ROOF, 2 x 6 R.R. FRONT ELEVATION 36" METAL DOOR FOR MECHANICAL CLOSET ACCESS SIDE ELEVATION (E) TRASH / (N) MECH. CLOSET(N) MECHANICAL CLOSET 123 SECTION A 2 x 6 R.R. @ 16" O.C. 4 x 6 HDR 2 x 4 STUDS 1/2" PLYWD BOTH SIDES STUCCO FINISH BOTH SIDES ASPHALT SHINGLES CLASS "B", w/ 1/2" PLYWD, #30 FELT METAL FLASHING (E) METAL DOOR(E) BLOCK WALL A1.3 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer PROPOSED TRASH ENCLOSURE PLAN EXISTING TRASH ENCLOSURE AT REAR OF BUILDING A1.4 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer APPLICATION FOR HARDSHIP EXCEPTION DR. GONZALES A1.5 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer HEALTH DEPARTMENT APPROVAL LETTER A1.8 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer STORE FRONT DETAIL A1.9 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer STORE FRONT DETAIL EXISTING & DEMO FLOOR PLAN N (E) TRASH ENCLOSURE (E) 60x48 (E) SIDEWALK 3 8 H U N T I N G T O N D R . (E) 60x48(E) 60x48 (E) 92x84 (E ) 5 4 x 5 4 ℄ (E) RECEPTION(E) OFFICE 1 (E) COMP. & COMM RM (E) CONFERENCE ROOM (E) HALLWAY (E) UNISEX RESTROOM (E) UNISEX RESTROOM (E) OPEN WORKSPACE (E) UNISEX RESTROOM (E) CORRIDOR (E) OFFICE (E) OPEN WORKSPACE (E) CORRIDOR (E) LADDER ROOF ACCESS (E ) 3 6 " (E ) 3 6 " (E ) 3 6 " (E ) 3 6 " (E) 36" (E ) 3 6 " (E) 36"(E ) 3 6 " (E ) 3 6 " (E) 36" (E) 36" (E) 36" (E) 36" (E) 36" (E ) 3 6 " (E ) 5 4 x 5 4 (E ) 3 6 " (E) 36" (E) 3 6 " (E ) S H E L V E S (E) STORAGE (E) DOUBLE HT RM (E) DÉJÀ VU MED SPA (NOT A PART OF) (E) OFFICE 2 (E) OFFICE 3 (E) OFFICE 4 (E) MTL. DOOR & GATE TO BE REMOVED (SECURITY ENTRANCE) (E) GLASS ENTRY DOORS & WINDOWS TO BE REMOVED (E) 48" LOW WALL TO BE MODIFIED FOR COUNTER USE (REF A2.2 & A6.1) (E) PARKING (REF A1.1) (E) PRIVATE GATED ENTRANCE (E ) S T O R E F R O N T A G E PR O P E R T Y L I N E 5 0 ' EXISTING 74.8 SF VESTIBULE SPACE BETWEEN STOREFRONT AND SECURITY ENTRANCE (E) ELEC. METERS (E) BRICK VENEER (TO REMAIN) 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer A2.1 EXISTING & DEMO PLAN PROPOSED FLOOR PLAN N (E) SIDEWALK (N) WAITING AREA(N) RECEPTION (N) OP #1 (N) OP #4 (N) OFFICE (E) LADDER ROOF ACCESS (E) 60x48(E) 60x48(E) 60x48 (E) 92x84 (E ) 3 6 " (E) 36" (E ) 3 6 " (E) 36"(E ) 3 6 " (E ) 3 6 " (N) 36" (E) 36" (E) 36" (E ) 3 6 " (E ) 5 4 x 5 4 (N) OP #2 (E) 3 6 " (N) STERILIZATION AREA (E) UNISEX RESTROOM (E ) S H E L V E S (E) STORAGE 3 8 H U N T I N G T O N D R . ℄ (E) DÉJÀ VU MED SPA (NOT A PART OF) (N) 36" (N) 36" (E) COMP. & COMM RM (N) DOORS & WINDOWS FRONT ENTRY (REF A1.8) (E) 48" LOW WALL TO BE MODIFIED FOR COUNTER USE SEE DET 1 A6.1 (E) UNISEX RESTROOM (N) OP #3 (E) HALLWAY(E) PARKING (REF A1.1) (E) EMPTY SUITE (NOT A PART OF) (E) PRIVATE GATED ENTRANCE (N) 36" (N) CONSULTING (N) OFFICE MANAGER EXISTING 74.8 SF VESTIBULE SPACE IS BEING ADDED TO EXTEND THE PROPOSED WAITING AREA PR O P E R T Y L I N E 5 0 ' (E) ADA RESTROOM SEE A6.1 FOR ADA DETAILS (E ) S T O R E F R O N T A G E MO N I T O R (N) CT (E) ELEC. METERS (N) COUNTER 101 102 103104 105106107 108 109 110 111 112 113 114 115 116 (E) CORRIDOR A4.1 1 (E) BRICK VENEER (TO REMAIN) (E) TRASH ENCLOSURE (N) 36" (N) MECH. CLOSET A7.1 1 A7.1 2 101 102 103 104 105 106 107 108 109 A4.2 A A2.2 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer PROPOSED PLAN EXIT S N REFLECTIVE CEILING PLAN 3 8 H U N T I N G T O N D R . ℄ PROPERTY LINE 146' PROPERTY LINE 146' (E) (N) (E) (E) (E) (E) (E) (E) (E) (E)(E)(E) (E) (E) (E) (N) (N)(N)(N) (N) (E)(E)(E)(E) GFI (E) (E ) E L E C T R I C A L ME T E R S (E) SS S S S S(E) (E) (E) S EXIT S (N) (E) S S (E)(E) S(E)S (E)EX I T EX I T S SS(E)(E)(E) EX I T NOTE: NO CHANGE TO EXISTING CEILING AND NO CHANGE TO EXISTING SUSPENDED T-BAR EXISTING STUCCO CEILING TO BE REFINISHED TO SMOOTH TEXTURE, NO T-BAR IS BEING PROPOSED (E)(E) (E)(E) NEW NON BEARING WALL 1SCALE 3/4" = 1'-0" A4.1 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer REFLECTIVE CEILING PLAN SECTION DETAIL AT ENTRANCE ASCALE 3/4" = 1'-0" A4.2 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer SECTION DETAIL # 3 8 H U N T I N G T O N D R . ℄ ENTRY 19 30 101 102 103104 105106107 108 109 110 111 112 113 114 115 116 TR A V E L DI S T A N C E 29 ' - 5 " TRAV E L DISTA N C E 13'-9" TR A V E L DI S T A N C E 43 ' - 6 " TR A V E L DI S T A N C E 55 ' - 2 " TR A V E L DI S T A N C E 56 ' - 0 " TR A V E L DI S T A N C E 51 ' - 8 " TR A V E L DI S T A N C E 34 ' - 1 0 " TR A V E L DI S T A N C E 31 ' - 2 " TRAVEL DISTANCE 72'-11" TRAVEL DISTANCE 69'-6" TRAVEL DISTANCE 60'-8" TRAVEL DISTANCE 73'-6" TRAVEL DISTANCE 20'-6" EXIT #2 EGRESS SIZING CALCULATION 19 OCCUPANTS X 0.2 = 3.8 LINEAR INCHES REQUIRED EXISTING = 36 INCHES PROVIDED EXIT #1 EGRESS SIZING CALCULATION 30 OCCUPANTS X 0.2 = 6 LINEAR INCHES REQUIRED NEW = 72 INCHES PROVIDED (E) TRASH ENCLOSURE (N) MECH. CLOSET N LIFE SAFETY FLOOR PLAN A5.1 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer LIFE SAFETY FLOOR PLAN, OCCUPANT LOAD A6.1 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer ADA NOTES RECEPTION COUNTER WALL ADA DETAIL 1 (N) 36" 30"x48" CLEAR SPACE 17 " - 1 8 " FLUSH ACTIVATOR ON WIDE SIDE 60" MIN. DIA. CLR. 24" MIN. CE N T E R L I N E TO F I X T U R E 18 " M I N 7'-1" 7' - 3 " ENLARGED FLOOR PLAN (E) ADA RESTROOM 1 NOTE: SEE SHEET A6.1 FOR ACCESSIBILITY DETAILS 60x56 CLEARANCE PER CBC 11B-604.3.1 (E) 36" (E ) S H E L V E S ENLARGED FLOOR PLAN (E) HALLWAY SINK 2 30"x48" CLEAR SPACE SINK DIAGRAM KNEES CLEARANCE 2B ST R I K E S I D E E D G E O F DO O R / O P E N I N G F R A M E 1'-0" WHITE INTERNATIONAL SYMBOL OF ACCESSIBILITY BLUE BACKGROUND COLOR 15090 OF FEDERAL STANDARD NUMBER 595B BUILDING ENTRY SIGNAGE (SECURE TO STOREFRONT GLASS W/ ADHESIVE). PROVIDE PLASTIC BACKING ON OTHER SIDE OF GLASS FOR COVERAGE. ADHESIVE SHALL BE COMPATIBLE W/ GLASS APPLICATION. 6" 6" 60 " A. F . F . FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY CL BUILDING ENTRY SIGN 3 11B-703.2 RAISED CHARACTERS. RAISED CHARACTERS SHALL COMPLY WITH SECTION 11B-703.2 AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH SECTION 11B-703.3. RAISED CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 11B-703.4. 11B-703.2.1 DEPTH RAISED CHARACTERS SHALL BE 1/32 INCH (0.8 mm) MINIMUM ABOVE THEIR BACKGROUND. 11B-703.2.2 CASE CHARACTERS SHALL BE UPPERCASE. 11B-703.2.3 STYLE CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. 11B-703.2.5 CHARACTER HEIGHT CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8 INCH MINIMUM AND 2 INCHES MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I". 11B-703.3 BRAILLE. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS 11B-703.3 AND 11B-703.4. 11B-703.3.1 DIMENSIONS AND CAPITALIZATION BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL COMPLY WITH TABLE 11B-703.3.1 11B-703.4 INSTALLATION HEIGHT AND LOCATION SIGNS WITH TACTILE CHARACTERS SHALL COMPLY WITH SECTION 11B-703.4. 11B-703.4.1 HEIGHT ABOVE FINISH FLOOR OR GROUND. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS. 11B-703.4.2 LOCATION WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDE AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES MINIMUM BY 18 INCHES MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. WHERE PERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMS AND SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR SPACE. 11B-703.5 VISUAL CHARACTERS SHALL COMPLY WITH SECTION 11B-703.5. 11B-703.5.1 FINISH AND CONTRAST CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. 11B-703.6 PICTOGRAMS PICTOGRAMS SHALL COMPLY WITH SECTION 11B-703.6. 11B-703.6.1 PICTOGRAM FIELD PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6 INCHES MINIMUM. CHARACTERS AND BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. TACTILE EXIT SIGN EXIT 4" 4" NOTES: TACTILE EGRESS SIGNAGE (SECURE TO STOREFRONT GLASS W/ ADHESIVE). PROVIDE PLASTIC BACKING OVER OTHER SIDE OF GLASS FOR COVERAGE. ADHESIVE SHALL BE COMPATIBLE w/ GLASS APPLICATION. EXIT 60 " M A X . RAISED GRADE 2 BRAILLE: "EXIT". A. F . F . 48 " M I N . A. F . F . BUILDING EXIT SIGN 4 EXIT ROUTE SIGN 5 9" MIN. 6" M I N . 2" M A X . 5/ 8 " M I N . 1/ 2 " M A X . 3/ 8 " M I N . NOTES: 1. RAISED CHARACTERS SHALL COMPLY WITH CBC 11B-703.2 AND SHALL BE DUPLICATED IN BRAILLE. 2. BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH CBC 11B-703.3. 3. SIGNS WITH TACTILE CHARACTERS SHALL BE INSTALLED IN ACCORDANCE WITH CBC 11B-703.4 4. ALL VISUAL CHARACTERS SHALL COMPLY WITH CBC 11B-703.5 5. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH, AND SHALL CONTRAST WITH THEIR BACKGROUND PER CBC 11B-703.5. 6. EDGES OF SIGN SHALL COMPLY WITH CBC 11B-703.7.2.6.4. RAISED GRADE 2 BRAILLE CHARACTERS REFER TO NOTE #1 ROUTE EXIT 2" M A X . 5/ 8 " M I N . 1/ 2 " M A X . 3/ 8 " M I N . "EXIT ROUTE" A7.1 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer ADA NOTES DOOR SCHEDULE NO.ROOM NAME SIZE ENTRY 2 - 3'-0" x 7'-0" THK.TYPE MAT'L DOOR FINISH WAITING AREA HDW. SET.NO.MAT'L FINISH HEAD FRAME JAMB REMARKS B A1.8 A1.8101 102 3'-0" x 7'-0"1-3/4"A PAINTED 2 PAINTED # UNISEX RESTROOM103 3'-0" x 7'-0"1-3/4"A PAINTED 1 HALLOW METAL SOLID CORE SOLID CORE PAINTED 104 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E) 105 OP #4 2 - 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E) 106 OFFICE 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E) 107 COMP & COMM RM 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E) PRIVATE ENTRY 3'-0" x 7'-0"(E)(E)(E)(E)(E)(E)(E)(E)108 PRIVATE GATE 3'-0" x 7'-0"109 (E)(E)(E)(E)(E)(E) 1 2 1 2 (E)(E) (E)(E) (E)(E) (E)(E) (E)(E) 11 (E) LEVER TYPE 1, 4, 5, 9 1, 2, 3, 4, 5, 6, 8, 9 1, 2, 7 1, 4, 5, 7 1-3/4"GLASS PANE FACTORY PER MANUFACTURE PUSH-PULL HALLOW METAL PAINTED HALLOW METAL REMARKS DOOR HINGES: USE 3-1/2" SCREWS (ALL HARDWARE TO BE STAINLESS STEEL) SIGNAGE: "MEN" / "WOMEN" / "UNISEX" ON TOILET ROOM DOOR DOOR CLOSER: HEAVY DUTY - AMERICAN DEVICE SERIES 6301 or LCN 4021 RESTROOMS THAT OPEN INTO HALLWAY OR OPEN SPACE MUST BE COMPLETELY ENCLOSED WITH SELF-CLOSING DOORS. 1 2 3 4 5 CLEAN, REPAIR AS REQUIRED KICK PLATE, FULL WIDTH OF DOOR @ 10 INCH MIN HT. AT BASE (36" HT. AT IMPACT DOOR) PROVIDE ACCESSIBLE IDENTIFICATION SYMBOLS6 7 8 9 ALL WOOD DOORS TO BE PREFINISHED "STAINED AT HOLLOW METAL DOOR FRAME TO BE BLACK FACTORY". COLOR TO BE MATTE BLACK. G.C. TO INSTALL 10 EXTERIOR DOORS ARE SELF-CLOSING, AND RODENT PROOFED 11 CRL ENTICE HP+ ENTRANCE FRONT DOOR SYSTEM, INSTALL PER MANUFACTURE SPECIFICATIONS 12 DOORS AND GATES SERVING AN OCCUPANT LOAD OF 50 OR MORE SHALL SWING IN THE DIRECTION OF TRAVEL. DOOR NOTES HARDWARE UNISEX RESTROOM MECHANICAL CLOSET 3'-0" x 7'-0"110 1, 4, 5, 10,1-3/4"SOLID CORE PAINTED PER MANFACTURE HALLOW METAL PAINTED SET #1:PASSAGE DOOR - NON RATED 3 EA BUTT HINGES 1 SELF CLOSER 1 MORTISE LOCK 1 FLOOR STOP 2 KICK PLATE SET #2:OFFICE - NON RATED 3 EA BUTT HINGES 1 MORTISE LOCK 1 FLOOR STOP 1 LEVER TYPE HANDLE 1 LEVER TYPE HANDLE 1.G.C. TO VERIFY THAT EXISTING DOORS TO REMAIN ARE IN GOOD WORKING CONDITION. 2.ALL EXISTING DOORS TO REMAIN SHALL KEEP THE EXISTING HARDWARE U.N.O. OR FOUND TO NOT FUNCTION PROPERLY. G.C. TO CLEAN AND REPAIR HARDWARE TO AS-NEW CONDITION. 3.NEW BEST LOCK LEVER TYPE HARDWARE, FINISH TO MATCH EXISTING. G.C. TO VERIFY IN FIELD. 4.EXIT DOORS SHALL BE OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. CBC 1010.1.9 5.G.C. TO PROVIDE SIGNAGE WITH 1-INCH HIGH LETTERING ON MAIN EXIT /DOOR "THIS DOOR TO REMAIN UN-LOCKED WHEN BUILDING IS OCCUPIED." 6.ALL FINISH HARDWARE SHALL COMPLY WITH ALL GOVERNING CODES AND ACCESSIBILITY CODES. [CBC 11B-404.2.7 AND 11B-309.4] 7.ALL DOOR EDGES SHALL BE PRIMED AND PAINTED. VERIFY COLOR WITH INTERIOR ELEVATIONS. 8.G.C. SHALL PROVIDE A FLOOR MOUNTED DOOR STOP FOR DOORS THAT SWING AGAINST THE WALL. 9.ALL DOOR SILENCERS SHALL BE INSTALLED AFTER DOOR AND FRAME HAVE RECEIVED FINAL PAINTED. 10. INSTALL CAULKING AROUND DOOR FRAME JAMBS, HEAD AND AT BOTTOM OF FRAME. 11. DOOR OPENING FORCE: FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN, EXTERIOR OR INTERIOR HINGED DOORS WITH CLOSERS AND SLIDING OR FOLDING DOORS, SHALL NOT EXCEED FIVE POUNDS (22.2 N) MAXIMUM. 12. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES THAT ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. (11B-309.4). OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MINIMUM AND 44" MAXIMUM ABOVE THE FINISH FLOOR OR GROUND (11B-404.2.7) 13. ALL NEW DOORS MUST BE EQUIPPED WITH LEVEL TYPE HANDLE. 1 5/8"2" 5/8" MIN. (TYP.) PA R T I T I O N WI D T H 1/ 2 " EA C H S I D E 2" 2" 5/8" TYPE "X" GYPSUM BOARD EACH SIDE HOLLOW METAL FRAME DOOR - PER SCHEDULE 3" = 1'-0" SCALE 2"2" PARTITION WIDTH 3" = 1'-0" SCALE 5/8" TYPE "X" GYPSUM BOARD EACH SIDE EXTEND GYPSUM BOARD INTO FRAME 5/8" MIN. JAMB ANCHOR HOLLOW METAL FRAME DOOR - PER SCHEDULE STANDARD RABBET 2" 5/ 8 " 5/ 8 " M I N . (T Y P . ) 1/2" EA. SIDE (TYP.) 2 INTERIOR DOOR HEAD INTERIOR DOOR JAMB 1, 4, 5, 7 7 1, 4, 5, 7, 10 7, 13 PER MANFAC. PER MANFAC. 14. LANDINGS OR FLOOR LEVEL AT DOORS SHALL NOT BE MORE THAN 1/2-INCH BELOW THE THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1/4-INCH AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL. [CBC 11B-404.2.5] 15. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. [CBC 11 B-404.2.1 0] 16. PROVIDE A LEVEL LANDING ON EACH SIDE OF A DOOR EXTENDING 60" ON DIRECTION OF DOOR SWING AND 48" IN OPPOSITE DIRECTION OF DOOR SWING, MEASURED WITH DOOR CLOSED. [CBC 1 LB-404.2.4 AND TABLE 1 LB-404.2.4.1] 17. A LANDING SHALL EXTEND 24" PAST STRIKE SIDE OF EXTERIOR DOORS ON PULL SIDE AND 18" MINIMUM PAST STRIKE EDGE OF INTERIOR DOORS. PROVIDE 12" ON PUSH SIDE, IF THE DOOR HAS BOTH A LATCH AND A CLOSER. [CBC TABLE 11 B-404.2.4.1] 13 HARDWARE LOCK AND LATCHING COMPLIANCE WITH CBC 1010.2.4. DOOR TYPES TYPE - A TEMPERED GLASS DOOR PER SCHED. PER SCHED. 10" x WIDTH OF DOOR STAINLESS STEEL KICK PLATE WHERE OCCUR, TYP. MA T C H ( E ) 34 " M I N . - 4 4 " M A X . PE R S C H E D U L E TYPE - B 10 " MA T C H ( E ) 34 " M I N . - 4 4 " M A X . PE R S C H E D U L E PER MANFAC. 1 ADD 12 INCHES IF CLOSER AND LATCH ARE PROVIDED. 2 ADD 4 INCHES IF CLOSER AND LATCH ARE PROVIDED. 3 BEYOND HINGE SIDE. 4 ADD 4 INCHES IF CLOSER IS PROVIDED. 5 ADD 6 INCHES AT EXTERIOR SIDE OF EXTERIOR DOORS. 11B-404.1 GENERAL. DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 11B-404. 11B-404.2 MANUAL DOORS. MANUAL DOORS AND DOORWAYS, AND MANUAL GATES, INCLUDING TICKET GATES, SHALL COMPLY WITH SECTION 11B-404.2 11B-404.2.1 REVOLVING DOORS. MA 11B-404.2.1 REVOLVING DOORS, GATES, AND TURNSTILES. REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES SHALL NOT BE PART OF AN ACCESSIBLE ROUTE. 11B-404.2.2 DOUBLE-LEAF DOORS AND GATES. AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH SECTIONS 11B-404.2.3 AND 11B-404.2.4. 11B-404.2.3 CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES (813 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES (914 MM) MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES (864 MM) ABOVE THE FINISH FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES (864 MM) AND 80 INCHES (2032 MM) ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES (102 MM). EXCEPTIONS: 1. IN ALTERATIONS, A PROJECTION OF 5/8 INCH (15.9 MM) MAXIMUM INTO THE REQUIRED CLEAR WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP. 2. DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES (1981 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND. 3. DOORS, DOORWAYS, AND GATES NOT PROVIDING FULL USER PASSAGE SHALL PROVIDE A CLEAR WIDTH OF 20 INCHES (510 MM) MINIMUM. 11B-404.2.4 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH SECTION 11B-404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. 11B-404.2.4 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES AT DOORS AND GATES SHALL COMPLY WITH SECTION 11B-404.2.4. MANEUVERING CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE. 11B-404.2.4.1 SWINGING DOORS AND GATES. SWINGING DOORS AND GATES SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.1. 11B-404.2.4.2 DOORWAYS WITHOUT DOORS OR GATES, SLIDING DOORS, AND FOLDING DOORS. DOORWAYS LESS THAN 36 INCHES (914 MM) WIDE WITHOUT DOORS OR GATES, SLIDING DOORS, OR FOLDING DOORS SHALL HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 11B-404.2.4.2. 11B-404.2.4.3 RECESSED DOORS AND GATES. MANEUVERING CLEARANCES FOR FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION WITHIN 18 INCHES (457 MM) OF THE LATCH SIDE AT AN INTERIOR DOORWAY, OR WITHIN 24 INCHES (610 MM) OF THE LATCH SIDE OF AN EXTERIOR DOORWAY, PROJECTS MORE THAN 8 INCHES (203 MM) BEYOND THE FACE OF THE DOOR, MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE. 11B-404.2.4.4 FLOOR OR GROUND SURFACE. FLOOR OR GROUND SURFACE WITHIN REQUIRED MANEUVERING CLEARANCES SHALL COMPLY WITH SECTION 11B-302. CHANGES IN LEVEL ARE NOT PERMITTED. EXCEPTIONS: 1. SLOPES NOT STEEPER THAN 1:48 SHALL BE PERMITTED. 2. CHANGES IN LEVEL AT THRESHOLDS COMPLYING WITH SECTION 11B-404.2.5 SHALL BE PERMITTED. 11B-404.2.5 THRESHOLDS. THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE 1/2 INCH (12.7 MM) HIGH MAXIMUM. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTIONS 11B-302 AND 11B-303. 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES. THE DISTANCE BETWEEN TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL BE 48 INCHES (1219 MM) MINIMUM PLUS THE WIDTH OF DOORS OR GATES SWINGING INTO THE SPACE. MIN. 24" MIN. 24" MI N . 42 " MI N . 48 " MIN. 12"MI N . 48 " MI N . 60 " MIN. 18" MIN. 36" MI N . 60 " APPROACH DIRECTION FROM FRONT FROM SIDE FROM STOP/LATCH SIDE MIN. 32" MIN. 32" 48 INCHES 42 INCHES 42 INCHES 0 INCHES 0 INCHES 24 INCHES PERPENDICULAR TO DOORWAY PARALLEL TO DOORWAY (BEYOND LATCH UNLESS NOTED) MINIMUM MANEUVERING CLEARANCES MINIMUM MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS TYPE OF USE APPROACH DIRECTION PERPENDICULAR TO DOORWAY PARALLEL TO DOORWAY (BEYOND LATCH UNLESS NOTED) DOOR SIDE FROM FRONT FROM FRONT FROM HINGE SIDE FROM HINGE SIDE FROM LATCH SIDE FROM LATCH SIDE PULL PUSH PULL PUSH PULL PUSH 60 INCHES 48 INCHES 60 INCHES 44 INCHES 44 INCHES 60 INCHES 0 INCHES 18 INCHES 36 INCHES 22 INCHES 24 INCHES 24 INCHES (a) FRONT APPROACH, PULL SIDE (c) FRONT APPROACH, PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH (d) HINGE APPROACH, PULL SIDE MIN. 22" (f) HINGE APPROACH, PUSH SIDE MI N . 60 " (h) LATCH APPROACH, PULL SIDE MI N . 44 " (j) LATCH APPROACH, PUSH SIDE TABLE 11B-404.2.4.2 - MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS TABLE 11B-404.2.4.1 - MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES 3 1 4 2 1 DOORWAY WITH NO DOOR ONLY. 2 BEYOND POCKET/HINGE SIDE. 2 90° FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS MIN. 32" MIN. 36" >2 4 " (a) HINGED DOOR (b) SLIDING DOOR (c) FOLDING DOOR (d) DOORWAYS WITHOUT DOORS FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS AND GATES MIN. 12" MI N . 48 " X> 8 " X> 8 " MI N . 48 " 18" MIN. AT INTERIOR MI N . 60 " X> 8 " FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCE AT RECESED DOORS AND GATES (a) PULL SIDE (b) PUSH SIDE (c) PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH MI N . 48 " FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES (b) (a) 5 FROM POCKET/HINGE SIDE 42 INCHES 22 INCHES 1 MI N . 48 " (b) FRONT APPROACH, PUSH SIDE MI N . 48 " MIN. 22" (g) HINGE APPROACH, PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH MIN. 24"MI N . 48 " (k) LATCH APPROACH, PUSH SIDE, DOOR PROVIDED WITH CLOSER 24" MIN. AT EXTERIOR 48 " M I N . (c) 11B-404 DOOR AND DOORWAYS (E) LEVER TYPE (E) LEVER TYPE (E) LEVER TYPE (E) LEVER TYPE (E) LEVER TYPE A8.1 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer DOOR SCHEDULE, HARDWARE NOTES & DETAILS A9.1 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer ADA PARKING NOTES F1.1 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer FURNITURE SPECS ADS DENTAL CHAIR PACKAGE ELITE SERIES DENTAL COMPRESSOR ADP DENTAL COMPRESSOR CT SCAN X-RAY DENTAL SPECIFICATIONS SUGGESTED PARTITON CGN 1 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer GREEN NOTES CGN 2 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer GREEN NOTES CGN 3 38 E . H U N T I N G T O N D R AR C A D I A , C A 9 1 0 0 6 Revisions: This project is sold for use in the construction of one t.i. only. Any further use of this design without the express permission of the designer is prohibited. These drawings have been prepared to meet standards practices. However, local variations may require changes. Likewise, building code requirements vary with location and change from time to time. Before starting construction, the builder must review and be responsible for all details and dimensions, and insurance that these plans meet all current govermental requirements in your area. RG Design & Consulting Ow n e r : Sheet Contents: T. I . N E W D E N T I S T O F F I C E "S E D A T I O N A N D I M P L A N T D E N T I S T S " Printed on: Drawn by: Pr o j e c t : SHEET No. rg-design1@att.net Ramon A. Gallardo 122 N. CORDOVA ST. ALHAMBRA, Ca. 91801 ph (626) 864-0927 fax (626) 570-4473 LO Project No.: 2025-000 "CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO CONSTRUCTION" Written Dimensions Shall take preference over scaled dimensions and shall be verified on the Job Site. Any discrepancy shall be Brought to the notice of RGD prior to commencement of any work. Dec 03, 2025 Ad d r e s s : TR G O N Z A L E S Engineer GREEN NOTES REVISIONS BY REVISIONS BY REVISIONS BY REVISIONS BY