HomeMy WebLinkAbout11818 Clark St - 2025 -SI
T
E
P
L
A
N
&
I
N
F
O
R
M
A
T
I
O
N
IMG SPACE
A-
0
NO
PA
R
K
I
N
G
NO
PA
R
K
I
N
G
NO
PA
R
K
I
N
G
NO
PA
R
K
I
N
G
PA
R
K
I
N
G
NO
NO
PA
R
K
I
N
G
4'
6'-
1
"
ADA
ADA ADA ADA ADA
CLARK ST
PL
PL
PL
PL
PL
EXISTING SIDEWALK
PER CITY STANDARDS
EXISTING CURB &
GUTTER PER CITY
STANDARDS
NOT-A-PART
EXISTING APPROVED
DRIVE APPROACH
EXISTING BUILDING:
1ST FLOOR: 8,188 S.F.
2ND FLOOR: 1,800 S.F.
TOTAL BLDG. AREA: 9,988 S.F.
CONSTRUCTION TYPE: VB
OCC: B / F / S-1
GENERAL LAND USE:
COMMERCIAL
UNIVERSAL LAND USE:
COMMERCIAL/INDUSTRIAL
ZONING: C-1
APN: 8532-016-013
6,005 SQ. FT.
OCC: B / F /S-1
(NO CHANGES TO
EXISTING OCCUPANCY)
PROPOSED
LOWER LEVEL
AREA OF TENANT
IMPROVEMENT
(UNIT # 101)
6'-1
"
9'-6
"
9'-5
"
34'-9"
30'-1"
EA
S
T
B
O
U
N
D
N
E
I
G
H
B
O
R
:
PR
O
P
E
R
T
Y
A
P
N
:
8
5
3
2
-
0
1
6
-
0
1
7
AD
D
R
E
S
S
:
1
1
8
3
6
C
L
A
R
K
S
T
.
ZO
N
I
N
G
:
C
-
1
(
C
O
M
M
E
R
C
I
A
L
)
WE
S
T
B
O
U
N
D
N
E
I
G
H
B
O
R
:
PR
O
P
E
R
T
Y
A
P
N
:
8
5
3
2
-
0
1
6
-
0
1
2
AD
D
R
E
S
S
:
1
1
8
0
0
C
L
A
R
K
S
T
.
ZO
N
I
N
G
:
C
-
1
(
C
O
M
M
E
R
C
I
A
L
)
N SITE PLAN
SCALE: 1/16" = 1'-0"
SOUTH BOUND NEIGHBOR:
PROPERTY APN: 8532-016-018
ADDRESS: 11837 GOLDRING RD.
ZONING: C-1 (COMMERCIAL)
7'-
1
1
"
7'-9
"
8'-7
"
7'-
9
"
8'-
1
1
"
8'-9
"
8'-
9
"
9'-3
"
8'-
9
"
9'-
2
"
SCOPE OF WORK
TOTAL LAND COVERAGE:
EXISTING LANDSCAPED AREAS (NOT A PART)
19,050 SQ. FT.
635 SQ. FT.
99%
0.03%
CONSTRUCTION TYPE:
ZONE:
OCCUPANCY'S:
FIRE SPRINKLERS:
STORIES:
PROJECT ADDRESS
11818 CLARK ST.
ARCADIA, CA 91006
APPLICANT:
IMG SPACE
680 E COLORADO BLVD
PASADENA, CA 91101
DESIGNER:
GEORGE WONG 626-780-2199
SITE AREA ANALYSIS
GROSS LAND AREA
AREA
EXISTING BUILDING AREA (FOOTPRINT)
EXISTING CONCRETE HARDSCAPE / CURBING
EXISTING A.C. PAVING
8,188 SQ. FT.
951 SQ. FT.
9,915 SQ. FT.
- ALL INTERIOR WALLS ARE TO BE NON-BEARING, PARTITION WALLS.
- NO IMPROVEMENTS TO EXISTING SITE DURING THIS PERMIT.
SITE DATA
C-1 (COMMERCIAL)
B / F/S-1
VB
TWO STORIES
YES
PROPERTY OWNER:
IKRUSHER INC.
11818 CLARK ST
ARCADIA, CA 91006
SQ. FT.
19,060 SQ. FT.
SQ. FT. % COVERAGE
42.9%
5.04%
52%
TENANT IMPROVEMENT ON AN EXISTING BUILDING UNIT 101, 8188 SQ. FT. OF AN EXISTING BUILDING
WITH A TOTAL AREA OF 9,988 SQ. FT. THE PROPOSED TENANT IMPROVEMENT IS TO TAKE PLACE ON
UNIT #101 FOR A PROPOSED MANUFACTURE, OFFICE, AND PRODUCT STORAGE.
-RELOCATION OF MECHANICAL SUPPLY & RETURN WITHIN AREA. NO ADDITIONAL OR REMOVAL OF
EXISTING NUMBER OF SUPPLY / RETURN. CARBON AIR FILTERS AND EXHAUST FANS TO BE ADDED
- NEW ELECTRICAL PER ELECTRICAL PLAN.
- NEW MECHANICAL PER MECHANICAL PLAN.
- NO ADD ON SQUARE FOOTAGE TO EXISTING BUILDING DURING THIS PERMIT.
NICOLE HUANG 626-866-3566
NICOLEH@IMGSPACE.US
CHARLIE ZHANG 907-987-9950
GENERAL REQUIREMENTS
- THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED
ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL
BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.)
OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN
TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE
PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR
ADDITIONAL EXPENSES.
- AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS
LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY
CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE
FUEL GAS PIPING. (PER ORDINANCE WORK OVER $10,000.) SEPARATE PLUMBING
PERMIT IS REQUIRED.
- PROVIDE ULTRA-LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION.
EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER
CONSUMPTION.
- A COPY OF THE EVALUATION AND/OR CONDITIONS OF LISTING SHALL BE MADE
AVAILABLE AT THE JOB SITE.
APPLICABLE CODES:
THESE PLANS SHALL COMPLY WITH THE LOCAL MUNICIPAL CODE AND 2022 EDITION OF
THE CALIFORNIA BUILDING CODE WITCH ADOPTS THE 2022 INTERNATIONAL BUILDING
CODE, 2022 CMC, 2022 CPC, AND THE 2022 CEC AND CALIFORNIA AMENDMENTS.
CODES:
BUILDING CODES:........................................................2022 CALIFORNIA BUILDING CODE (C.B.C.)
ELECTRICAL CODE:.............................................. 2022 CALIFORNIA ELECTRICAL CODE (C.E.C.)
MECHANICAL CODE:........................................... 2022 CALIFORNIA MECHANICAL CODE (C.M.C.)
PLUMBING CODE:..................................................... 2022 CALIFORNIA PLUMBING CODE (C.P.C.)
ENERGY CODE (T24 -PART 6):...................................... 2022 CALIFORNIA ENERGY STANDARDS
ACCESSIBILITY CODE:.............................................. 2022 CALIFORNIA BUILDING CODE - CH. 11
GREEN CODE (T24 - PART 11):.................................................. 2022 CALIFORNIA GREEN CODE.
FIRE CODE:.......................................................................... 2022 CALIFORNIA FIRE CODE (C.F.C.)
SEE GREEN CODE, NON-RESIDENTIAL CHECK LIST ON PAGE GC-1 FOR MANDATORY
MEASURES. GENERAL CONTRACTORS AND SUB-CONTRACTORS TO COMPLY WITH
APPLICABLE MEASURES.
GOVERNING CODES
(UNIT # 102)
SHEET #
A-102
A-2
A-3
A-4
A-5
A-6
SHEET INDEX
GENERAL DESCRIPTION
A-0 EXISTING SITE PLAN & GENERAL PROJECT INFORMATION
PROPOSED FLOOR PLAN
PROPOSED OCCUPANCY PLAN
PROPOSED EGRESS PLAN
EXISTING ROOF PLAN
A-7 - A-15
A-16 - A-18
A-19
ACCESSIBILITY GENERAL STANDARDS
GREEN CODE GENERAL NOTES
CALIFORNIA GREEN BUILDING & NON RESIDENTIAL
MANDATORY MEASURES
A-20 CONSTRUCTION GENERAL NOTES
SD-1 STRUCTURAL DETAILS
TOTAL SPACES PROVIDED =22 SPACES
-NO CHANGES TO EXISTING PARKING UNDER CERTIFICATE OF OCCUPANCY
S-1 OCCUPANCY
DRY STORAGE,
JANITOR ROOMS, UTILITY
ROOMS
S.F.
42 SQ. FT.
RATIO
1/300
OCCUPANTS
1
TOTALS = 6,005 S.F. 46 OCCUPANTS
PARKING DATA
EXISTING PARKING & LOADING PER PARKING GUIDELINES
SECTION 12.21A.4 (1 PER 500 SQ. FT.)
EXISTING BUILDING FOOTPRINT = 9,988 SQ. FT.
EXISTING STANDARD (9' x 18') PARKING STALLS
EXISTING COMPACT (8.5' x 16') PARKING STALLS
EXISTING ACCESSIBLE PARKING STALLS
TOTAL EXISTING PARKING SPACES=
20 SPACES REQUIRED
17 - EXISTING
3 - EXISTING
2 - EXISTING
22 SPACES
B OCCUPANCY
OFFICES, RESTROOMS
& CORRIDORS SERVING
THESE AREAS
F OCCUPANCY
INDUSTRIAL MANUFACTURE
SERVING THESE AREAS
BUILDING DATA - TABLE 1004.1.2
RATIO
1/150
S.F.
2,792 SQ. FT.
S.F.
2,592 SQ. FT.
RATIO
1/100
OCCUPANTS
19
OCCUPANTS
26
KEYED NOTES
1
2
3
4
5
6
7
8
9
EXISTING 9'x18' ACCESSIBLE PARKING SPACE, SEE SHEET A-8 FOR
DETAILS (SLOPE NOT TO EXCEED 5% IN THE DIRECTION OF TRAVEL AND
2% CROSS SLOPE.)
EXISTING ACCESSIBLE PARKING STALL EMBLEM PAINTED AS SHOWN
EXISTING 6'X18' ACCESSIBILITY ACCESS BAY w/ 4" WD. BLUE STRIPES
EXISTING 4' MINIMUM WIDTH A.D.A. PATH OF TRAVEL PER 2022 CBC, NOT
TO EXCEED 5% SLOPE IN DIRECTION OF TRAVEL AND 2% MAXIMUM IN
CROSS SLOPE
EXISTING COVRERED APPROVED TRASH ENCLOSURE PER CITY
STANDARDS
LOCATION OF EXISTING ELECTRICAL TRANSFORMER PER CITY STANDARDS
EXISTING 9' x 18' STANDARD PARKING STALL PER CITY STANDARDS
EXISTING 8.5' x 16' COMPACT PARKING STALL PER CITY STANDARDS
EXISTING 6" CONCRETE CURB PER CITY/COUNTY STANDARDS
10
11
12
EXISTING LOCATION OF ACCESIBILITY RAMP
EXISTING LOCATION OF A.C. PAVING TO REMAIN
EXISTING LOCATION OF LANDSCAPE AREAS TO REMAIN
13 EXISTING LOCATION OF SWITCHGEAR
VICINITY MAP
IKRUSHER INC.
11818 CLARK ST
ARCADIA, CA 91006
TENANT IMPROVEMENT FOR
N
11818 CLARK ST
ARCADIA, CA 91006
OFFICE / WAREHOUSE / MANUFACTORY
BUILDING TENANT IMPROVEMENT
1
2
34
5
6
8'-
6
"
8 7
9
10
11
12
13
7
PROPROSED REFLECTIVE CEILING PLAN
PROPOSED FIRE & LIFE SAFETY PLAN
SD-2 IMP PANEL WALL DETAILS
E000 ELECTRICAL SPECIFICATION
E001 SINGLE LINE DIAGRAM / SCHEDULES
E100 LIGHTING PLAN
E200 POWER PLAN
TE00 TITLE 24 - INDOOR
M000 MECHANICAL NOTES
M001 MECHANICAL SCHEDULES
M002 MECHANICAL DETAILS
M100 MECHANICAL PLAN
M101 MECHANICAL PLAN - ROOF PLAN
TM00 MECHANICAL TITLE 24-1
TM01 MECHANICAL TITLE 24-2
P000 PLUMBING NOTES & SCHEDULES
P001 PLUMBING DETAILS
P002 PLUMBING SPECIFICATION SHEETS
P100 WASTE & VENT PLAN
P200 WATER PLAN
TP00 TITLE 24
I-KRUSHER
11818 CLARK ST,
ARCADIA,
CA 91006
ARCHITECT'S APPROVAL:
7'-11"
ENTRANCE 1
3'
7'-11"
ENTRANCE 2
3'
3'-
2
"
A-101 EXISTING FLOOR PLAN
S-1 STRUCTURAL OF THE ROOF
DEFERRED SUBMITTALS
1.FIRE SPRINKLERS
2. FIRE ALARMS
3. ALL SIGNAGE AND GRAPHIC
** GC RESPONSIBLE TO SUBMIT SHOP DRAWINGS PRIOR TO INSTALLATION.
E:\IMG Space\Stamp\2026 GW STAMP 2.jpg
SD-3 IMP PANEL SPEC & NOTES
IMG SPACE
A-
2
10" SEMI-RIGID
DUCTING
PROPOSED REFLECTIVE CEILING PLAN
SCALE: 3/16" = 1'-0"
EF-1
MARK QTY.
CF-1 4
MANUFACTURER
2 GREENHECK
CAN-FAN
MODEL
SP-A200
EXHAUST FAN SCHEDULE
SERVICE CFM RPM
CONTINUOUS 150
MAX-FAN CONTINUOUS 1019
900
2990
DIRECT
DIRECT
DRIVE DISCHARGE INLET WHEEL TYPE WEIGHT VOLTS/PH/HZ SONES
SIDE BOTTOM CURVED 24 LBS 120 - 1 - 60 3.5
TOP BOTTOM MIXED FLOW 12 LBS 120 - 1 - 60 11.5
"CAN FAN"
CAN-FILTER
INTAKE 10"
"CAN FAN"
MAX-FAN 10"
10" DIAMETER VENT
PIPE CAP BY ACTIVE
VENTILATION
(OR SIMILAR)
EXISTING RETURN AIR
GRILL
EXHAUST FAN.
10" CAC-FAN
EXHAUST FAN SEE
PLANS FOR EXACT
SIZES & MODELS
INSTALLED w/
CAN-FILTER (CAN-LITE
10" 1500 CFM)
RETURN AIR GRILLE W/
ROUND ELBOW CONNECTION
AND INSUL. FLEXIBLE DUCT
RUNOUT
EXISTING SUPPLY AIR GRILL
EEXIT
EREXIT ILLUMINATED
EXIT ROUTE SIGN
L.E.D. RECESSED
LIGHTING FIXTURE
EMERGENCY BACKUP
LIGHTING
ILLUMINATED EXIT SIGN TO BE EQUIPPED WITH A
BACK-UP BATTERY TO RUN
FOR AT LEAST 2 HOURS
UNINTERRUPTED.
AIR DIFFUSER DRYWALL TYPE
SYMBOL
REFLECTIVE CEILING LEGEND
DESCRIPTION
C
D
E
X 8-0" HT.
CEILING LEGEND
CEILING MATERIAL
CEILING HEIGHT
PROPOSED 5/8" GYPSUM BOARD CEILING
EXISTING GYPSUM BOARD CEILING TO REMAIN
EXISTING OPEN CEILING, EXPOSED TO STRUCTURE.
REMARKS
EF-2
FILTRATION SYSTEM DETAIL
N
13
'
-
0
"
H
T
.
F
13
'
-
0
"
H
T
.
C
9'-
0
"
H
T
.
C
9'-
0
"
H
T
.
C
9'-
0
"
H
T
.
D
9'-0" HT.D
OP
E
N
CE
I
L
I
N
G
E
9'
-
0
"
H
T
.
C
9'-0" HT.C
E E E
ER
ER
E E
ER
ER
ER
EF-1150 CFMEF-1
150 CFM
FIXTURE TO REMAINE
2' X 4' LED LIGHTING
2' X 4' LED LIGHTING
EXISTING
EXISTING
E
L.E.D. RECESSED
LIGHTING FIXTURE
E E
E E
E E E E
E E E E
EE
E
E
E E E
E E
RE
F
L
E
C
T
I
V
E
C
E
I
L
I
N
G
P
L
A
N
I-KRUSHER
11818 CLARK ST,
ARCADIA,
CA 91006
ARCHITECT'S APPROVAL:
CF
1
CF
1
GV
1
CF
1 GV
1
CF
1
GV
1
GRAVITY INTAKE
AIR SUPPLY DEVICE
F IMP PANEL CEILING
E:\IMG Space\Stamp\2026 GW STAMP 2.jpgE:\IMG Space\Stamp\2026 GW STAMP 2.jpg
IMG SPACE
A-
1
0
2
10
"
DO
O
R
H
I
N
G
E
S
I
D
E
MI
N
.
DO
O
R
OP
E
N
I
N
G
2"
10
"
MI
N
.
12"
M
A
X
.
1/
4
"
M
A
X
.
10
"
DO
O
R
H
I
N
G
E
S
I
D
E
MI
N
.
3/8
"
T
O
1
/
2
"
60
"
M
A
X
I
M
U
M
48
"
M
I
N
I
M
U
M
4"
4"
2"
10
"
HI
N
G
E
S
I
D
E
O
F
D
O
O
R
FINISH SCHEDULE
DOOR SCHEDULE
- ALL DOORS SHALL HAVE LEVER HARDWARE (HANDLE). THE LEVER HARDWARE SHALL BE CURVED WITH A RETURN TO WITHIN 1/2" OF THE DOOR
TO PREVENT CATCHING ON THE CLOTHING OF PERSONS EGRESS PER SECTION 11B-404.2.8 AND PART 2, PER SECTION 12-10-202F
REQUIREMENTS FOR LEVER HARDWARE AS ADOPTED BY THE STATE FIRE MARSHAL.
NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED
THE MAXIMUM ALLOWABLE FLOW RATES SPECIFIED IN
SECTION 5.303.3. SEE SHEET A- FOR GRN SHEETS.
FIXTURE NAME
SHOWER HEAD FIXTURE ...................
KITCHEN FAUCET ................................
LAVATORY ............................................
WATER CLOSET ...................................
UTILITY FAUCET ...................................
DOOR ELEVATIONS
4"
SEE ACCESSIBLE
SIGNAGE INFORMATION
EXIT
HARDWARE:
· (3) 4A. BALL BEARING HINGES
BB1279, 4-1/2" x 4-1/2"
BY: HAGER OR EQUAL
· (3) SILENCERS - SR64
BY: IVES OR EQUAL
· (1) CLOSER - ITS96 SERIES
WHEN REQUIRED.
BY: DORMA OR EQUAL
· FLOOR STOP -FS17
BY: IVES OR EQUAL
· 10'' HI. KICK PLATE NO.
8400-S32D (PUSH SIDE0
BY: IVES OR EQUAL
FINISH FLOOR DOOR D3 DOOR D2 FINISH FLOOR DOOR D1
THE TRIANGLE SHALL CONTRAST
WITH THE CIRCLE SYMBOL. EITHER
LIGHT ON DARK BACKGROUND OR
DARK ON A LIGHT BACKGROUND.
HARDWARE:
· (3) 4A. BALL BEARING HINGES
BB1279, 4-1/2" x 4-1/2"
BY: HAGER OR EQUAL
· (3) SILENCERS - SR64
BY: IVES OR EQUAL
· (1) CLOSER - ITS96 SERIES
WHEN REQUIRED.
BY: DORMA OR EQUAL
· FLOOR STOP -FS17
BY: IVES OR EQUAL
· 10'' HI. KICK PLATE NO.
8400-S32D (PUSH SIDE0
BY: IVES OR EQUAL
S6 S7
HARDWARE:
• (3) 4A. BALL BEARING HINGES
BB1279, 4-1/2" X 4-1/2"
BY: HAGER OR EQUAL
• (3) SILENCERS - SR64
BY: IVES OR EQUAL
• (1) CLOSER - ITS96 SERIES
WHEN REQUIRED.
BY: DORMA OR EQUAL
• FLOOR STOP -FS17
BY: IVES OR EQUAL
S3
S5
NO
SMOKING
7"
S2 ROUTE S4
4"
DIRECTION VARIES
EXIT
ROUTE
UPPERCASE CHARACTERS
LETTERING RAISED 1/32"
FLOW RATE
1.8 GPM @ 80 PSI
1.5 GPM @ 60 PSI
0.4 GPM @ 60 PSI
1.28 GAL. / FLUSH
1.5 GPM @ 60 PSI
WATER EFFICIENCY SECTION 5.303 OF CALIFORNIA GREEN CODE
WALL FINISH.
HOLLOW MTL. DR.
STUD ANCHOR
EXTERIOR FINISH
INTERIOR FINISH
SEE PLAN FOR
EXACT LOCATION
'J' MOLDING FOR ALL
EXTERIOR FINISHES
DOOR PER SCHED.
ALUMINUM THRESHOLD
TO EXTEND BEYOND
EXPANSION JOINT
FINISH FLOOR
DOOR PER SCHED.
FRAME WIDTH
FIELD VERIFY
METAL DOOR FRAME EXTERIOR DOOR THRESHOLD CARPET OR INTERIOR FLOORING TO CONCRETE
S1 EXIT
SEALANT
EXPANSION JOINT 4"5/8" TO 2" HIGH RAISED 1/32" SANS
SERF NON-GLARE HI. CONTRAST
EX. DRAINAGE
PLANE
CERAMIC TILE. SEE
FINISH SCHEDULE
WATER EFFICIENCY SCHD.
DOOR THRESHOLD DETAILS
EXIT
EXIT ILLUMINATED EXITING SIGNS
EXITS SIGNS SHALL BE ILLUMINATED AT ALL TIMES. INSURE
CONTINUED ILLUMINATION FOR A DURATION OF NOT LESS THAN
90-MIN. IN CASE OF PRIMARY POWER LOSS, THE SIGN SHALL BE
CONNECTED TO A STORAGE (BACK-UP) BATTERY, UNIT
EQUIPMENT OR AN ON-SITE BACK-UP POWER GENERATOR.
- DOOR CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A
POSITION OF 12 DEGREES FROM THE LATCH IN 5 SECONDS MINIMUM PER SECTION 11B-404.2.8.
- DOOR OPENING FORCE OF 5 POUNDS MAXIMUM FOR INTERIOR AND EXTERIOR DOORS. A DOOR OPENING FORCE OF 15 POUNDS MAXIMUM FOR
ALL FIRE RATED DOORS SHALL BE PROVIDED PER SECTION 11B-404.2.9 OF CALIFORNIA BUILDING CODE 2019.
- ALL DOORS SHALL COMPLY WITH C.B.C. 2019 SECTION 1008.1.9 THRU SECTION 1008.1.10.2.
- ALL DOOR GLAZING SHALL BE TEMPERED GLASS.
- DOORS USED AS MEANS OF EGRESS SHALL BE EQUIPPED WITH FULL PANIC HARDWARE PER C.BC. 2019 SECTION 1008.1.10 (SEE EGRESS PLAN).
DOOR GENERAL NOTES
- EACH DOOR IN A MEANS OF EGRESS FROM A GROUP A, OR ASSEMBLY AREA NOT CLASSIFIED AS AN ASSEMBLY OCCUPANCY, HAVING AN
OCCUPANT LOAD OF 50 OR MORE SHALL NOT BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS PANIC HARDWARE. BUILDING CODE 1010.1.10.
FIRE CODE 1010.1.10.
- THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. CBC 1133B.2.6.
ALSO KNOWN AS KICK-PLATE.
- EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.
BUILDING CODE 1010.1.9.
- ALL EXIT DOORS AND GATES FROM OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK, UNLESS IT IS PANIC HARDWARE. CBC 1008.1.9.
- ALL DOORS ABUTTING INTO EGRESS PATH OF TRAVEL (CORRIDORS) SHALL HAVE INSTALLED A SELF-CLOSING DEVICE.
MINIMUM HEIGHT: BASELINE
OF LOWEST COPY MOUNTED
NO LOWER THAN 48" ABV. F.F.
MAXIMUM HEIGHT: BASELINE
OF HIGHEST COPY MOUNTED
NO HIGHER THAN 60" ABV. F.F.
FINISH FLOOR
DOOR PER SCHD.
CONCRETE EPOXY
SEALANT PRODUCT
S1 TACTILE EXITING SIGN WITH LEGEND "EXIT"
S2 TACTILE SIGN WITH LEGEND "EXIT ROUTE"
S3 INTERNATIONAL SYMBOL OF ACCESSIBILITY
S4 TACTILE SIGN STATING NEAREST EXIT ROUTE
S5 CONTRASTING SIGN WITH LEGEND 'NO SMOKING'
S6 WALL MOUNTED TACTILE SIGN STATING "TYPE OF RESTROOM"
S7 DOOR MOUNTED TACTILE SIGN STATING "TYPE OF RESTROOM"
ALLOWED
MOUNTING
AREA
DOOR HARDWARE NOTES
E1 3'-0" x 7'-0"
E2 3'-0" x 6'-10"
--
1-3/4"
3
2
H.C.M.
S.C.S.
EXISTING 36" DOOR - TEMPERED GLASS - SELF CLOSING
DEVICE PRESENT - NO SPECIAL KNOWLEDGE REQ. TO OPERATE
EXISTING 36" DOOR - SELF CLOSING - NO LATCHING DEVICE
PRESENT - NO SPECIAL KNOWLEDGE REQ. TO OPERATE
- ALL HARDWARE TO BE NICKEL PLATED W/ SATIN FINISH U.N.O.
- ALL EXTERIOR DOORS TO HAVE DEAD BOLTS.
- ALL RESTROOMS TO HAVE PRIVACY LOCKS
D3 3'-0" x 6'-10" 1-3/4"
# SIZE
D1 3'-0" x 6'-10"
THK.
1-3/4"
QTY.
8
2
TYPE.
H.C.M.
H.C.M.
REMARKS
20-MIN. FIRE RATED DOOR - SELF CLOSING
36" DOOR - SELF CLOSING - NO LATCHING DEVICE PRESENT -
NO SPECIAL KNOWLEDGE REQ. TO OPERATE
Ø
%
AMP.
ABV.
BOT.
BM.
#
T
#
K
@ AT
AMPERES
A.F.F. ABOVE FINISH FLOOR
ABOVE
BLDG. BUILDING
BRD. BOARD
BOTTOM
BEAM
CAB. CABINET / CABINETS
C1D1 CLASS 1, DIVISION 1
C1D2 CLASS 1, DIVISION 2
CLG. CEILING
CLR. CLEAR
COMP. COMPARTMENT
CT.CIRCUIT
DN. DOWN
DECO. DECONTAMINATION
DIA.
DP.
EA,
DIAMETER
DEEP / DEPTH
D.W. DISH WASHER MACHINE
(E) / EX.EXISTING
EACH
ELEC. ELECTRICAL
ELEV. ELEVATION
EQUIP. EQUIPMENT
F.F.
FRZ. FREEZER
F.S.
# SIZE QTY. TYPE TYPE REMARKS
1 6'-0" x 5'-0"1 FIXED ALUMINUM 1/2" THK. TEMPERED GLASS SIDELIGHT FOR DOORS (45 MIN RATED)
X X
X
X
X
WINDOW SCHEDULE
#BASE
C1 GYP. BOARD
F1
F2
CONCRETE
VINYL FLOORING
F3 CERAMIC TILE
#BASE
SCALE: 3/16" = 1'-0"
#
W1
BASE
GYP. BOARD
W2 EPS PANEL
W3 VINYL COVING BASE
WALL FINISH SCHEDULE
FINISH
(2) LAYERS OF ENAMEL PAINT, COLOR: _______
CODE: ______ BY: SHERWIN WILLIAMS OR EQUAL
MOISTURE RESISTANT EXPANDED POLYSTYRENE (EPS) PANEL,
COLOR: WHITE
3/8" MIN. COVING FLOORING BASE BOARD,
COLOR: TO MATCH WALL FINISH
FLOORING FINISH SCHEDULE
FINISH
(1) LAYER OF DB CLASSIC 9510 RESISTANT URETHANE
OVER (1) LAYER OF DB CLASSIC 3300 EPOXY
VINYL SHEET TYPE OF FLOORING
BY: TRAFFIC MASTER, COLOR: REDWOOD ACACIA
20" SQ. CERAMIC TILE BY: EMSER TILE,
SERIES: REALM, COLOR: REAL DOMAIN
CEILING FINISH SCHEDULE
FINISH
(2) LAYERS OF ENAMEL PAINT, COLOR: _______
CODE: ______ BY: SHERWIN WILLIAMS OR EQUAL
FINISH NOTES:
1) ALL MATERIAL USED AS INTERIOR TRIM SHALL HAVE A MINIMUM CLASS C FLAME SPREAD AND SMOKE-DEVELOPED INDEX
SHALL NOT EXCEED 10% OF THE WALL OR CEILING AREA IN WHICH IT IS ATTACHED.
2) CURTAINS, DRAPERIES,FABRIC HANGINGS, AND SIMILAR COMBUSTIBLE DECORATIVE MATERIALS SUSPENDED FROM WALLS
OR CEILINGS SHALL NOT EXCEED 10% OF THE WALL OR CEILING AREA TO WHICH SUCH MATERIALS AREA ATTACHED.
SYMBOLS LEGEND & ABBREVIATIONS
SYMBOL DESCRIPTION
#
#
DENOTES KEYED NOTE NUMBER
SEE KEYED NOTES LEGEND
DENOTES DOOR NUMBER
SEE DOOR SCHEDULE
DETAIL NUMBER DESIGNATION
PAGE NUMBER DESIGNATION
VIEW DIRECTION OF INTERIOR ELEVATION
SHEET NUMBER
NUMBER OF INTERIOR ELEVATION
DENOTES EQUIPMENT SPECIFICATION
SEE EQUIPMENT SCHEDULE
VIEW DIRECTION OF DETAIL / SECTION
DETAIL NUMBER / SECTION NUMBER
SHEET NUMBER
INDICATES SIGNAGE TYPE AND LOCATION
SEE ADA SIGNAGE INFORMATION
THERMOSTAT FOR HVAC SYSTEM
SEE MECHANICAL DRAWINGS FOR SPEC.
INDICATES FINISH MATERIALS PER
FINISH SCHEDULE ON SHEET A-5
INDICATES SECURITY DOOR EQUIPPED
w/ CARD READER FOR ENTRY
PERCENTAGE / PERCENT
DIAMETER GRD. GRADE
G.F.I. GROUND FAULT INTERRUPTER
G.F.P. GROUND FAULT PROTECTION
GYP. GYPSUM
HI.HIGH
HR.
HT.
J.
HOUR / HOURS
HEIGHT
ELECTRICAL JUNCTION BOX
LAV. LAVATORY
LG.LENGTH
MAX. MAXIMUM
MIN. MINIMUM
MTL. METAL
NO. / # NUMBER
O.H. OVER-HEAD
PREP. PREPARING
REF,
RM. ROOM
SPEC. SPECIFICATION(S)
SYS. SYSTEM
THK. THICK / THICKNESS
TYP. TYPICAL
V.
WIDTH
U.N.O. UNLESS NOTED OTHERWISE
VENT
FINISH FLOOR
FINISH SURFACE
G.C. GENERAL CONTRACTOR
VTR. VENT THRU ROOF
W.C. WATER CLOSET
WD.
W.H. WATER HEATER
W.P. WATERPROOF
YR.YEAR / YEARS
ADA SIGNAGE INFORMATION
MOUNTING HEIGHT FOR TACTILE SIGNAGE:
SIGNS CAN NOW BE MOUNTED WITHIN A RANGE OF SPACE WHICH ALLOWS
FOR A CONSISTENT TOP HEIGHT FOR DIFFERENT SIZED SIGNS ALONG A HALL.
SIGNS ARE TO BE MOUNTED AT A HEIGHT TO ALLOW THE BASELINES OF
RAISED CHARACTERS TO BE LOCATED BETWEEN 48" AND 60" ABOVE THE
GROUND.
MOUNTING LOCATION MUST ALLOW A PERSON
TO APPROACH WITHOUT ENCOUNTERING
PROTRUDING OBJECTS OR STANDING WITHIN
THE SWING PATH OF THE DOOR
REFRIGERATOR
MICRO. MICROWAVE
REMARKS
SEAL PRIOR INSTALLING COVE BASE BOARD
MOISTURE, SCRATCH AND CUT RESISTANT
3/16" GROUT JOINT RECOMMENDATION
REMARKS
TEXTURE:________
SYMBOL
WALL LEGEND
DESCRIPTION
2x4 NON-BEARING IMP PANEL WALLS @ 48" O.C.
TYP.
2x4 NON-BEARING STUD WALLS @ 16" O.C. TYP.
EXISTING 2x6 PARTITION WALLS TO REMAIN
EXISTING 2x4 PARTITION WALLS TO REMAIN
INDICATING AREA OF 1-HOUR FIRE RATING
REMARKS
TEXTURE: SMOOTH AND WASHABLE SURFACE
INSTALL PER MANUFACTURE'S INSTRUCTIONS
2
3
KEYED NOTES
1 COUNTER SURFACE TO BE 34" MAX. ABV. F.F.
OCCUPANT LOAD SIGN TO BE POSTED IN A
CONSPICUOUS PLACE NEAR ALL MAIN ENTRANCES
(CBC 1008.1.9.)
PROVIDE ABOVE DOOR SIGN LEGEND STATING - "DOOR
TO REMAIN UNLOCKED DURING BUSINESS HOURS"
4 FIRE EXTINGUISHER LOCATION (TYPICAL AS SHOWN)
5 EXISTING STRUCTURAL COLUMN TO REMAIN (TYPICAL)
7 PROPOSED "NO LOITERING OR SOLICITING" SIGNANGE
PER CITY ORDINANCES AND STATE PENAL CODES
8 EXISTING FIRE ALARM PANEL
X
X
MANUFACTURE AREA PRODUCT STORAGE
OFFICE
EMPLOYEE BREAK ROOM
LOUNGE ROOM
DELIVER OFFICECOMMON HALLWAY
OFFICE
RECEPTION
A.R.R.1
N
CORRIDOR
A.R.R.2
RECEPTION
10'-7" X 19'-5"
9' CLG.
W1 F2 C1
MANUFACTURE
STOCK
(LIMITED ACCESS)
11'-8" X 19'-5"
9' CLG.
PRODUCT
16'-10" X 19'-5"
9' CLG.
9' CLG.
22'-8" X 17'-7"
9' CLG.
22'-9" X 38'-10"
13'-0" CLG.
W1 F2 C4
45'-4" X 52'-10"
13'-0" CLG.
W3 F2 C4
15'-7" X 8'-8"
9' CLG.
11'-0" X 14'-5"
9' CLG.
28'-6" X 10'-9"
9' CLG.
16'-0" CLG.
W1 F1 C2
C2 OPEN CEILING OPEN CEILING, EXPOSED TO STRUCTURE
PROPOSED FLOOR PLAN
W2W1
W1 F2 C1
W1 F2 C1
W1 F2 C1
W1 F2 C1
W1 F2 C1
W1 F2 C1
W1 F2 C1
STORAGE
EXIT EXIT EXIT
EXIT
EX
I
T
EXIT
EX
I
T
EX
I
T
EXIT
(LIMITED ACCESS)
6'-10" X 7'-7"
9' CLG.
W3 F2 C1W2W1
6'-10" X 7'-7"
9' CLG.
W3 F2 C1W2
E1
E1
D3
E2
D3
D1
D1 D1
D1
D1
D1
E1 E1
E3 9'-0" x 9'-0"--2 EXISTING GARAGE ROLLER DOOR - MOTOR CLOSING - NO LATCHING DEVICE
E3E3
52
'
-
1
0
"
22'-4"6"11'-7"6"21'-9"6"
D2 D2
1
2S1 S1 S1
S2S2
S2
EXIT
2333
8
7 11'-4"10"11'5"28'-6"
4
9
5
9 PROPOSED WORK TABLE
7
S5
S5
S7S6S7S6
1
D3 6'-0" x 6'-10" 1-3/4"2 36" DOOR - SELF CLOSING - PANIC HARDWARE - NO SPECIAL
KNOWLEDGE REQ. TO OPERATEH.C.M.
SD
-
2
5 SD
-
1
SD
-
1
11
SD-2
18
'
-
8
"
29
'
-
8
"
37'-11"5"7'5"22'-9"10'-7"11'-3"16'-10"
109'-3"
19
'
-
5
"
5"
5'-
6
"
12
'
-
6
"
6'-
3
"
8'
-
9
"
6"
W
A
L
L
36
"
W
I
N
D
O
W
H
E
I
G
H
T
4"
1/2" THK. GYP.
BOARD STEEL SLIDING FIRE WINDOWS,
3/4-HOUR I.C.B.O REPORT # 2781 OR EQUAL
INTERLOCK STILE WINDOW JAMB
WINDOW JAMB SLIDING PANEL FURNISHED
w/ POSTITIVE LATCHING 1/8"
THK. STEEL LATCH
WINDOW DIMENSION
PASS-THRU WINDOW
SCALE: N.T.S.
EQUIPPED w/ SPRING
ACTIVATED AUTOMATIC
CLOSERS
4" METAL STUD
WALL @ 16" O.C.
1/2" THK. GYP.
BOARD
WINDOW SILL
1-1/8"
FRAME AND SASH TO
BE 16 GA. STEEL w/ 12 GA.
GUSSETS & 16 GA. ANGLES
WINDOW TO BE FACTORY
GLAZED w/ CLEAR 1/4"
THK. WIRE GLASS OR 3/16"
THK. CLEAR FIRELITE.
ANSI Z97.1 & ASTM C1036.
INDIVIDUAL LITES SHALL
NOT EXCEED 720 SQ. IN.
WINDOW HEADER
SINK
4
SD
-
1
WALL TO BE ONE
HOUR FIRE-RATED
PR
O
P
O
S
E
D
F
L
O
O
R
P
L
A
N
I-KRUSHER
11818 CLARK ST,
ARCADIA,
CA 91006
ARCHITECT'S APPROVAL:
3'-9"1'-11"
NO RACK STORAGE IN THIS PROJECT. SINGLE LAYER
PALLET ON GROUND STORAGE ONLY. VERTICAL
STORAGE BELOW 60 INCH HEIGHT.
AISLES IN STORAGE AREA ARE KEEPING IN NOT LESS
THAN 96 INCHES.
STORED PRE-FILLED CARTRIDGES WITHOUT ANY OIL
OR LIQUID IN STORAGE AREA. NON HAZARDOUS
MATERIALS BEEN STORED. (CFC 5003.1.1)
10
11
12
MANUFACTURED FOR PACKAGING REBRAND
PRODUCT ONLY. THE PRODUCT ARE PRE-FILLED
CARTRIDGES WITHOUT ANY OIL OR LIQUID.
13
4'7'7'-5"
13
10 11 12 10 11 12
E:\IMG Space\Stamp\2026 GW STAMP 2.jpg
4"
4"
E:\IMG Space\Stamp\2026 GW STAMP 2.jpg
IMG SPACE
SD
-
2
I-KRUSHER
11818 CLARK ST,
ARCADIA,
CA 91006
IM
P
W
A
L
L
D
E
T
A
I
L
S
6
FOAM IN PLACE
INSULATION
FIELD CUT
THERMAL BREAK
(AS REQUIRED)
IMP CEILING
FOAM IN PLACE
INSULATION
IMP WALL
16 GA ANGLE
CLOSURE TRIM TO
MATCH IMP FINISH
CONTINUOUS SEALANT
FIELD CUT
THERMAL BREAK
HANGER ROD
REQUIRED TO
SUPPORT ANGLE
WHERE CLOSEST
CHANNEL HANGER IS
GREATER THAN 4'-0"
AWAY FROM WALL
COUPLING
3/8" NUT &
WASHER
VAPOR
BARRIER
CONTINUOUS
SEALANT
IMP CEILING
CLOSURE TRIM TO
MATCH IMP FINISH
IMP WALL
CONTINUOUS
SEALANT
#10x3/4" TEK SCREWS
AT 12" OC
CONTINUOUS 26 GA TRIM
BUTYL SEALANT
BOTH SIDES OF TEE
4"x3"x3/16" EXTRUDED
ALUMINUM CEILING TEE
FILL 1/2" GAP BETWEEN
PANEL WITH FOAM IN
PLACE INSULATION
#12 - 14x1-1/4" CAP SCREWS
AT 30" OC BOTH SIDES
3/8" x 1-1/2" BOLT WITH(3) 3/8" WASHERS AND
(1) LOCK-NUT PER BOLT
3/8" DIA EYE COUPLER NUT
3/8" HANGER
ALL-THREAD ROD AT EVERY
JOIST/BEAM LOCATION
(NO GREATER THAN 6'-0" OC)
HEX NUT AND LOCK WASHER
4"x4"x14 GA PLATE WASHER
SELF-ADHERING VAPOR
BARRIER
FOUR TIGHT TURNS IN 1-1/2"
SEISMIC BRACE PLATE
8 GA SPLAY BRACE
WIRE IN FOUR DIRECTIONS
3/8" ALL-THREAD
HANGER ROD
SEISMIC BRACE PLATE
(AS REQUIRED PER CODE)
NOTE:
SPACE ABOVE CEILING MUST
BE VENTILATED
IMP CEILING. EXTERIOR
SIDE OF PANEL MUST BE
ON BOTTOM OF CEILING
26 GA SNAP ON COVER
OVER TEE (MATCH CEILING
PANEL FINISH)
ROD INSULATION, EXTEND 3'-0"
ABOVE CEILING AT COOLER
OR FREEZER CONDITIONS
FOAM IN PLACE
INSULATION
IMP WALL
16 GA ANGLE
CLOSURE TRIM TO
MATCH IMP FINISH
CONTINUOUS SEALANT
FIELD CUT
THERMAL BREAK
HANGER ROD REQUIRED TO
SUPPORT ANGLE WHERE
CLOSEST CHANNEL
HANGER IS GREATER THAN
4'-0" AWAY FROM WALL
COUPLING
3/8" NUT & WASHER
VAPOR BARRIER
CONTINUOUS SEALANT
IMP CEILING
NUT AND STEEL
BEARING WASHER
3/8" HANGER
ALL-THREAD ROD
EXISTING ROOF JOIST
BOTTOM CHORD
TYPICAL WALKABLE
CEILING ROD CONNECTION
SINGLE NUT AND STEEL
BEARING WASHER
NUT AND STEEL
BEARING WASHER
COORDINATE FINAL LOCATION
WITH STRUCTURAL ENGINEER
SINGLE NUT AND STEEL
BEARING WASHER
3/8" HANGER
ALL-THREAD ROD
ESCUTCHEON SET IN FULL
BED OF SEALANT
IMP CEILING, SEE
WALL TYPES SHEET
JOINT SEALANT ALL
AROUND, TYP
CUSTOMER EQUIPMENT
IMP JOINTS TYP.
4 IMP WALL TO IMP CEILING DET.
FINISHED FLOOR
0' - 0"
EXISTING ROOF
+12'-6"
5 IMP CEILING PENETRATION
1 IMP WALL WINDOW FRAME
2 FRAMED OPENING SILL-OFF MODULE W/EXTRUSION
MANUFACTURE AREA PRODUCT STORAGE
METAL BOTTOM TRACK
INSULATION
CONCRETE SLAB
CLOSURE TRIM TO
MATCH IMP FINISH
IMP WALL
CONTINUOUS
SEALANT
WELDED PLATE
SEE DETAIL ON ENLARGE
IMP WALL BOTTOM PLATE
3 IMP WALL BOTTOM TRACK ENLARGE PLAN
4" IMP PANEL
E:\IMG Space\Stamp\2026 GW STAMP 2.jpgE:\IMG Space\Stamp\2026 GW STAMP 2.jpg
IMG SPACE
SD
-
3
I-KRUSHER
11818 CLARK ST,
ARCADIA,
CA 91006
IM
P
W
A
L
L
S
P
C
E
&
N
O
T
E
S
E:\IMG Space\Stamp\2026 GW STAMP 2.jpg
THE MATERIAL USE FOR IMP WALL AND POST MUST MEET ASTM E119-2020