Loading...
HomeMy WebLinkAbout11818 Clark St - 2025 -SI T E P L A N & I N F O R M A T I O N IMG SPACE A- 0 NO PA R K I N G NO PA R K I N G NO PA R K I N G NO PA R K I N G PA R K I N G NO NO PA R K I N G 4' 6'- 1 " ADA ADA ADA ADA ADA CLARK ST PL PL PL PL PL EXISTING SIDEWALK PER CITY STANDARDS EXISTING CURB & GUTTER PER CITY STANDARDS NOT-A-PART EXISTING APPROVED DRIVE APPROACH EXISTING BUILDING: 1ST FLOOR: 8,188 S.F. 2ND FLOOR: 1,800 S.F. TOTAL BLDG. AREA: 9,988 S.F. CONSTRUCTION TYPE: VB OCC: B / F / S-1 GENERAL LAND USE: COMMERCIAL UNIVERSAL LAND USE: COMMERCIAL/INDUSTRIAL ZONING: C-1 APN: 8532-016-013 6,005 SQ. FT. OCC: B / F /S-1 (NO CHANGES TO EXISTING OCCUPANCY) PROPOSED LOWER LEVEL AREA OF TENANT IMPROVEMENT (UNIT # 101) 6'-1 " 9'-6 " 9'-5 " 34'-9" 30'-1" EA S T B O U N D N E I G H B O R : PR O P E R T Y A P N : 8 5 3 2 - 0 1 6 - 0 1 7 AD D R E S S : 1 1 8 3 6 C L A R K S T . ZO N I N G : C - 1 ( C O M M E R C I A L ) WE S T B O U N D N E I G H B O R : PR O P E R T Y A P N : 8 5 3 2 - 0 1 6 - 0 1 2 AD D R E S S : 1 1 8 0 0 C L A R K S T . ZO N I N G : C - 1 ( C O M M E R C I A L ) N SITE PLAN SCALE: 1/16" = 1'-0" SOUTH BOUND NEIGHBOR: PROPERTY APN: 8532-016-018 ADDRESS: 11837 GOLDRING RD. ZONING: C-1 (COMMERCIAL) 7'- 1 1 " 7'-9 " 8'-7 " 7'- 9 " 8'- 1 1 " 8'-9 " 8'- 9 " 9'-3 " 8'- 9 " 9'- 2 " SCOPE OF WORK TOTAL LAND COVERAGE: EXISTING LANDSCAPED AREAS (NOT A PART) 19,050 SQ. FT. 635 SQ. FT. 99% 0.03% CONSTRUCTION TYPE: ZONE: OCCUPANCY'S: FIRE SPRINKLERS: STORIES: PROJECT ADDRESS 11818 CLARK ST. ARCADIA, CA 91006 APPLICANT: IMG SPACE 680 E COLORADO BLVD PASADENA, CA 91101 DESIGNER: GEORGE WONG 626-780-2199 SITE AREA ANALYSIS GROSS LAND AREA AREA EXISTING BUILDING AREA (FOOTPRINT) EXISTING CONCRETE HARDSCAPE / CURBING EXISTING A.C. PAVING 8,188 SQ. FT. 951 SQ. FT. 9,915 SQ. FT. - ALL INTERIOR WALLS ARE TO BE NON-BEARING, PARTITION WALLS. - NO IMPROVEMENTS TO EXISTING SITE DURING THIS PERMIT. SITE DATA C-1 (COMMERCIAL) B / F/S-1 VB TWO STORIES YES PROPERTY OWNER: IKRUSHER INC. 11818 CLARK ST ARCADIA, CA 91006 SQ. FT. 19,060 SQ. FT. SQ. FT. % COVERAGE 42.9% 5.04% 52% TENANT IMPROVEMENT ON AN EXISTING BUILDING UNIT 101, 8188 SQ. FT. OF AN EXISTING BUILDING WITH A TOTAL AREA OF 9,988 SQ. FT. THE PROPOSED TENANT IMPROVEMENT IS TO TAKE PLACE ON UNIT #101 FOR A PROPOSED MANUFACTURE, OFFICE, AND PRODUCT STORAGE. -RELOCATION OF MECHANICAL SUPPLY & RETURN WITHIN AREA. NO ADDITIONAL OR REMOVAL OF EXISTING NUMBER OF SUPPLY / RETURN. CARBON AIR FILTERS AND EXHAUST FANS TO BE ADDED - NEW ELECTRICAL PER ELECTRICAL PLAN. - NEW MECHANICAL PER MECHANICAL PLAN. - NO ADD ON SQUARE FOOTAGE TO EXISTING BUILDING DURING THIS PERMIT. NICOLE HUANG 626-866-3566 NICOLEH@IMGSPACE.US CHARLIE ZHANG 907-987-9950 GENERAL REQUIREMENTS - THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. - AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWNSTREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE WORK OVER $10,000.) SEPARATE PLUMBING PERMIT IS REQUIRED. - PROVIDE ULTRA-LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. - A COPY OF THE EVALUATION AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. APPLICABLE CODES: THESE PLANS SHALL COMPLY WITH THE LOCAL MUNICIPAL CODE AND 2022 EDITION OF THE CALIFORNIA BUILDING CODE WITCH ADOPTS THE 2022 INTERNATIONAL BUILDING CODE, 2022 CMC, 2022 CPC, AND THE 2022 CEC AND CALIFORNIA AMENDMENTS. CODES: BUILDING CODES:........................................................2022 CALIFORNIA BUILDING CODE (C.B.C.) ELECTRICAL CODE:.............................................. 2022 CALIFORNIA ELECTRICAL CODE (C.E.C.) MECHANICAL CODE:........................................... 2022 CALIFORNIA MECHANICAL CODE (C.M.C.) PLUMBING CODE:..................................................... 2022 CALIFORNIA PLUMBING CODE (C.P.C.) ENERGY CODE (T24 -PART 6):...................................... 2022 CALIFORNIA ENERGY STANDARDS ACCESSIBILITY CODE:.............................................. 2022 CALIFORNIA BUILDING CODE - CH. 11 GREEN CODE (T24 - PART 11):.................................................. 2022 CALIFORNIA GREEN CODE. FIRE CODE:.......................................................................... 2022 CALIFORNIA FIRE CODE (C.F.C.) SEE GREEN CODE, NON-RESIDENTIAL CHECK LIST ON PAGE GC-1 FOR MANDATORY MEASURES. GENERAL CONTRACTORS AND SUB-CONTRACTORS TO COMPLY WITH APPLICABLE MEASURES. GOVERNING CODES (UNIT # 102) SHEET # A-102 A-2 A-3 A-4 A-5 A-6 SHEET INDEX GENERAL DESCRIPTION A-0 EXISTING SITE PLAN & GENERAL PROJECT INFORMATION PROPOSED FLOOR PLAN PROPOSED OCCUPANCY PLAN PROPOSED EGRESS PLAN EXISTING ROOF PLAN A-7 - A-15 A-16 - A-18 A-19 ACCESSIBILITY GENERAL STANDARDS GREEN CODE GENERAL NOTES CALIFORNIA GREEN BUILDING & NON RESIDENTIAL MANDATORY MEASURES A-20 CONSTRUCTION GENERAL NOTES SD-1 STRUCTURAL DETAILS TOTAL SPACES PROVIDED =22 SPACES -NO CHANGES TO EXISTING PARKING UNDER CERTIFICATE OF OCCUPANCY S-1 OCCUPANCY DRY STORAGE, JANITOR ROOMS, UTILITY ROOMS S.F. 42 SQ. FT. RATIO 1/300 OCCUPANTS 1 TOTALS = 6,005 S.F. 46 OCCUPANTS PARKING DATA EXISTING PARKING & LOADING PER PARKING GUIDELINES SECTION 12.21A.4 (1 PER 500 SQ. FT.) EXISTING BUILDING FOOTPRINT = 9,988 SQ. FT. EXISTING STANDARD (9' x 18') PARKING STALLS EXISTING COMPACT (8.5' x 16') PARKING STALLS EXISTING ACCESSIBLE PARKING STALLS TOTAL EXISTING PARKING SPACES= 20 SPACES REQUIRED 17 - EXISTING 3 - EXISTING 2 - EXISTING 22 SPACES B OCCUPANCY OFFICES, RESTROOMS & CORRIDORS SERVING THESE AREAS F OCCUPANCY INDUSTRIAL MANUFACTURE SERVING THESE AREAS BUILDING DATA - TABLE 1004.1.2 RATIO 1/150 S.F. 2,792 SQ. FT. S.F. 2,592 SQ. FT. RATIO 1/100 OCCUPANTS 19 OCCUPANTS 26 KEYED NOTES 1 2 3 4 5 6 7 8 9 EXISTING 9'x18' ACCESSIBLE PARKING SPACE, SEE SHEET A-8 FOR DETAILS (SLOPE NOT TO EXCEED 5% IN THE DIRECTION OF TRAVEL AND 2% CROSS SLOPE.) EXISTING ACCESSIBLE PARKING STALL EMBLEM PAINTED AS SHOWN EXISTING 6'X18' ACCESSIBILITY ACCESS BAY w/ 4" WD. BLUE STRIPES EXISTING 4' MINIMUM WIDTH A.D.A. PATH OF TRAVEL PER 2022 CBC, NOT TO EXCEED 5% SLOPE IN DIRECTION OF TRAVEL AND 2% MAXIMUM IN CROSS SLOPE EXISTING COVRERED APPROVED TRASH ENCLOSURE PER CITY STANDARDS LOCATION OF EXISTING ELECTRICAL TRANSFORMER PER CITY STANDARDS EXISTING 9' x 18' STANDARD PARKING STALL PER CITY STANDARDS EXISTING 8.5' x 16' COMPACT PARKING STALL PER CITY STANDARDS EXISTING 6" CONCRETE CURB PER CITY/COUNTY STANDARDS 10 11 12 EXISTING LOCATION OF ACCESIBILITY RAMP EXISTING LOCATION OF A.C. PAVING TO REMAIN EXISTING LOCATION OF LANDSCAPE AREAS TO REMAIN 13 EXISTING LOCATION OF SWITCHGEAR VICINITY MAP IKRUSHER INC. 11818 CLARK ST ARCADIA, CA 91006 TENANT IMPROVEMENT FOR N 11818 CLARK ST ARCADIA, CA 91006 OFFICE / WAREHOUSE / MANUFACTORY BUILDING TENANT IMPROVEMENT 1 2 34 5 6 8'- 6 " 8 7 9 10 11 12 13 7 PROPROSED REFLECTIVE CEILING PLAN PROPOSED FIRE & LIFE SAFETY PLAN SD-2 IMP PANEL WALL DETAILS E000 ELECTRICAL SPECIFICATION E001 SINGLE LINE DIAGRAM / SCHEDULES E100 LIGHTING PLAN E200 POWER PLAN TE00 TITLE 24 - INDOOR M000 MECHANICAL NOTES M001 MECHANICAL SCHEDULES M002 MECHANICAL DETAILS M100 MECHANICAL PLAN M101 MECHANICAL PLAN - ROOF PLAN TM00 MECHANICAL TITLE 24-1 TM01 MECHANICAL TITLE 24-2 P000 PLUMBING NOTES & SCHEDULES P001 PLUMBING DETAILS P002 PLUMBING SPECIFICATION SHEETS P100 WASTE & VENT PLAN P200 WATER PLAN TP00 TITLE 24 I-KRUSHER 11818 CLARK ST, ARCADIA, CA 91006 ARCHITECT'S APPROVAL: 7'-11" ENTRANCE 1 3' 7'-11" ENTRANCE 2 3' 3'- 2 " A-101 EXISTING FLOOR PLAN S-1 STRUCTURAL OF THE ROOF DEFERRED SUBMITTALS 1.FIRE SPRINKLERS 2. FIRE ALARMS 3. ALL SIGNAGE AND GRAPHIC ** GC RESPONSIBLE TO SUBMIT SHOP DRAWINGS PRIOR TO INSTALLATION. E:\IMG Space\Stamp\2026 GW STAMP 2.jpg SD-3 IMP PANEL SPEC & NOTES IMG SPACE A- 2 10" SEMI-RIGID DUCTING PROPOSED REFLECTIVE CEILING PLAN SCALE: 3/16" = 1'-0" EF-1 MARK QTY. CF-1 4 MANUFACTURER 2 GREENHECK CAN-FAN MODEL SP-A200 EXHAUST FAN SCHEDULE SERVICE CFM RPM CONTINUOUS 150 MAX-FAN CONTINUOUS 1019 900 2990 DIRECT DIRECT DRIVE DISCHARGE INLET WHEEL TYPE WEIGHT VOLTS/PH/HZ SONES SIDE BOTTOM CURVED 24 LBS 120 - 1 - 60 3.5 TOP BOTTOM MIXED FLOW 12 LBS 120 - 1 - 60 11.5 "CAN FAN" CAN-FILTER INTAKE 10" "CAN FAN" MAX-FAN 10" 10" DIAMETER VENT PIPE CAP BY ACTIVE VENTILATION (OR SIMILAR) EXISTING RETURN AIR GRILL EXHAUST FAN. 10" CAC-FAN EXHAUST FAN SEE PLANS FOR EXACT SIZES & MODELS INSTALLED w/ CAN-FILTER (CAN-LITE 10" 1500 CFM) RETURN AIR GRILLE W/ ROUND ELBOW CONNECTION AND INSUL. FLEXIBLE DUCT RUNOUT EXISTING SUPPLY AIR GRILL EEXIT EREXIT ILLUMINATED EXIT ROUTE SIGN L.E.D. RECESSED LIGHTING FIXTURE EMERGENCY BACKUP LIGHTING ILLUMINATED EXIT SIGN TO BE EQUIPPED WITH A BACK-UP BATTERY TO RUN FOR AT LEAST 2 HOURS UNINTERRUPTED. AIR DIFFUSER DRYWALL TYPE SYMBOL REFLECTIVE CEILING LEGEND DESCRIPTION C D E X 8-0" HT. CEILING LEGEND CEILING MATERIAL CEILING HEIGHT PROPOSED 5/8" GYPSUM BOARD CEILING EXISTING GYPSUM BOARD CEILING TO REMAIN EXISTING OPEN CEILING, EXPOSED TO STRUCTURE. REMARKS EF-2 FILTRATION SYSTEM DETAIL N 13 ' - 0 " H T . F 13 ' - 0 " H T . C 9'- 0 " H T . C 9'- 0 " H T . C 9'- 0 " H T . D 9'-0" HT.D OP E N CE I L I N G E 9' - 0 " H T . C 9'-0" HT.C E E E ER ER E E ER ER ER EF-1150 CFMEF-1 150 CFM FIXTURE TO REMAINE 2' X 4' LED LIGHTING 2' X 4' LED LIGHTING EXISTING EXISTING E L.E.D. RECESSED LIGHTING FIXTURE E E E E E E E E E E E E EE E E E E E E E RE F L E C T I V E C E I L I N G P L A N I-KRUSHER 11818 CLARK ST, ARCADIA, CA 91006 ARCHITECT'S APPROVAL: CF 1 CF 1 GV 1 CF 1 GV 1 CF 1 GV 1 GRAVITY INTAKE AIR SUPPLY DEVICE F IMP PANEL CEILING E:\IMG Space\Stamp\2026 GW STAMP 2.jpgE:\IMG Space\Stamp\2026 GW STAMP 2.jpg IMG SPACE A- 1 0 2 10 " DO O R H I N G E S I D E MI N . DO O R OP E N I N G 2" 10 " MI N . 12" M A X . 1/ 4 " M A X . 10 " DO O R H I N G E S I D E MI N . 3/8 " T O 1 / 2 " 60 " M A X I M U M 48 " M I N I M U M 4" 4" 2" 10 " HI N G E S I D E O F D O O R FINISH SCHEDULE DOOR SCHEDULE - ALL DOORS SHALL HAVE LEVER HARDWARE (HANDLE). THE LEVER HARDWARE SHALL BE CURVED WITH A RETURN TO WITHIN 1/2" OF THE DOOR TO PREVENT CATCHING ON THE CLOTHING OF PERSONS EGRESS PER SECTION 11B-404.2.8 AND PART 2, PER SECTION 12-10-202F REQUIREMENTS FOR LEVER HARDWARE AS ADOPTED BY THE STATE FIRE MARSHAL. NEW PLUMBING FIXTURES AND FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATES SPECIFIED IN SECTION 5.303.3. SEE SHEET A- FOR GRN SHEETS. FIXTURE NAME SHOWER HEAD FIXTURE ................... KITCHEN FAUCET ................................ LAVATORY ............................................ WATER CLOSET ................................... UTILITY FAUCET ................................... DOOR ELEVATIONS 4" SEE ACCESSIBLE SIGNAGE INFORMATION EXIT HARDWARE: · (3) 4A. BALL BEARING HINGES BB1279, 4-1/2" x 4-1/2" BY: HAGER OR EQUAL · (3) SILENCERS - SR64 BY: IVES OR EQUAL · (1) CLOSER - ITS96 SERIES WHEN REQUIRED. BY: DORMA OR EQUAL · FLOOR STOP -FS17 BY: IVES OR EQUAL · 10'' HI. KICK PLATE NO. 8400-S32D (PUSH SIDE0 BY: IVES OR EQUAL FINISH FLOOR DOOR D3 DOOR D2 FINISH FLOOR DOOR D1 THE TRIANGLE SHALL CONTRAST WITH THE CIRCLE SYMBOL. EITHER LIGHT ON DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. HARDWARE: · (3) 4A. BALL BEARING HINGES BB1279, 4-1/2" x 4-1/2" BY: HAGER OR EQUAL · (3) SILENCERS - SR64 BY: IVES OR EQUAL · (1) CLOSER - ITS96 SERIES WHEN REQUIRED. BY: DORMA OR EQUAL · FLOOR STOP -FS17 BY: IVES OR EQUAL · 10'' HI. KICK PLATE NO. 8400-S32D (PUSH SIDE0 BY: IVES OR EQUAL S6 S7 HARDWARE: • (3) 4A. BALL BEARING HINGES BB1279, 4-1/2" X 4-1/2" BY: HAGER OR EQUAL • (3) SILENCERS - SR64 BY: IVES OR EQUAL • (1) CLOSER - ITS96 SERIES WHEN REQUIRED. BY: DORMA OR EQUAL • FLOOR STOP -FS17 BY: IVES OR EQUAL S3 S5 NO SMOKING 7" S2 ROUTE S4 4" DIRECTION VARIES EXIT ROUTE UPPERCASE CHARACTERS LETTERING RAISED 1/32" FLOW RATE 1.8 GPM @ 80 PSI 1.5 GPM @ 60 PSI 0.4 GPM @ 60 PSI 1.28 GAL. / FLUSH 1.5 GPM @ 60 PSI WATER EFFICIENCY SECTION 5.303 OF CALIFORNIA GREEN CODE WALL FINISH. HOLLOW MTL. DR. STUD ANCHOR EXTERIOR FINISH INTERIOR FINISH SEE PLAN FOR EXACT LOCATION 'J' MOLDING FOR ALL EXTERIOR FINISHES DOOR PER SCHED. ALUMINUM THRESHOLD TO EXTEND BEYOND EXPANSION JOINT FINISH FLOOR DOOR PER SCHED. FRAME WIDTH FIELD VERIFY METAL DOOR FRAME EXTERIOR DOOR THRESHOLD CARPET OR INTERIOR FLOORING TO CONCRETE S1 EXIT SEALANT EXPANSION JOINT 4"5/8" TO 2" HIGH RAISED 1/32" SANS SERF NON-GLARE HI. CONTRAST EX. DRAINAGE PLANE CERAMIC TILE. SEE FINISH SCHEDULE WATER EFFICIENCY SCHD. DOOR THRESHOLD DETAILS EXIT EXIT ILLUMINATED EXITING SIGNS EXITS SIGNS SHALL BE ILLUMINATED AT ALL TIMES. INSURE CONTINUED ILLUMINATION FOR A DURATION OF NOT LESS THAN 90-MIN. IN CASE OF PRIMARY POWER LOSS, THE SIGN SHALL BE CONNECTED TO A STORAGE (BACK-UP) BATTERY, UNIT EQUIPMENT OR AN ON-SITE BACK-UP POWER GENERATOR. - DOOR CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IN 5 SECONDS MINIMUM PER SECTION 11B-404.2.8. - DOOR OPENING FORCE OF 5 POUNDS MAXIMUM FOR INTERIOR AND EXTERIOR DOORS. A DOOR OPENING FORCE OF 15 POUNDS MAXIMUM FOR ALL FIRE RATED DOORS SHALL BE PROVIDED PER SECTION 11B-404.2.9 OF CALIFORNIA BUILDING CODE 2019. - ALL DOORS SHALL COMPLY WITH C.B.C. 2019 SECTION 1008.1.9 THRU SECTION 1008.1.10.2. - ALL DOOR GLAZING SHALL BE TEMPERED GLASS. - DOORS USED AS MEANS OF EGRESS SHALL BE EQUIPPED WITH FULL PANIC HARDWARE PER C.BC. 2019 SECTION 1008.1.10 (SEE EGRESS PLAN). DOOR GENERAL NOTES - EACH DOOR IN A MEANS OF EGRESS FROM A GROUP A, OR ASSEMBLY AREA NOT CLASSIFIED AS AN ASSEMBLY OCCUPANCY, HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL NOT BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS PANIC HARDWARE. BUILDING CODE 1010.1.10. FIRE CODE 1010.1.10. - THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE. CBC 1133B.2.6. ALSO KNOWN AS KICK-PLATE. - EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. BUILDING CODE 1010.1.9. - ALL EXIT DOORS AND GATES FROM OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK, UNLESS IT IS PANIC HARDWARE. CBC 1008.1.9. - ALL DOORS ABUTTING INTO EGRESS PATH OF TRAVEL (CORRIDORS) SHALL HAVE INSTALLED A SELF-CLOSING DEVICE. MINIMUM HEIGHT: BASELINE OF LOWEST COPY MOUNTED NO LOWER THAN 48" ABV. F.F. MAXIMUM HEIGHT: BASELINE OF HIGHEST COPY MOUNTED NO HIGHER THAN 60" ABV. F.F. FINISH FLOOR DOOR PER SCHD. CONCRETE EPOXY SEALANT PRODUCT S1 TACTILE EXITING SIGN WITH LEGEND "EXIT" S2 TACTILE SIGN WITH LEGEND "EXIT ROUTE" S3 INTERNATIONAL SYMBOL OF ACCESSIBILITY S4 TACTILE SIGN STATING NEAREST EXIT ROUTE S5 CONTRASTING SIGN WITH LEGEND 'NO SMOKING' S6 WALL MOUNTED TACTILE SIGN STATING "TYPE OF RESTROOM" S7 DOOR MOUNTED TACTILE SIGN STATING "TYPE OF RESTROOM" ALLOWED MOUNTING AREA DOOR HARDWARE NOTES E1 3'-0" x 7'-0" E2 3'-0" x 6'-10" -- 1-3/4" 3 2 H.C.M. S.C.S. EXISTING 36" DOOR - TEMPERED GLASS - SELF CLOSING DEVICE PRESENT - NO SPECIAL KNOWLEDGE REQ. TO OPERATE EXISTING 36" DOOR - SELF CLOSING - NO LATCHING DEVICE PRESENT - NO SPECIAL KNOWLEDGE REQ. TO OPERATE - ALL HARDWARE TO BE NICKEL PLATED W/ SATIN FINISH U.N.O. - ALL EXTERIOR DOORS TO HAVE DEAD BOLTS. - ALL RESTROOMS TO HAVE PRIVACY LOCKS D3 3'-0" x 6'-10" 1-3/4" # SIZE D1 3'-0" x 6'-10" THK. 1-3/4" QTY. 8 2 TYPE. H.C.M. H.C.M. REMARKS 20-MIN. FIRE RATED DOOR - SELF CLOSING 36" DOOR - SELF CLOSING - NO LATCHING DEVICE PRESENT - NO SPECIAL KNOWLEDGE REQ. TO OPERATE Ø % AMP. ABV. BOT. BM. # T # K @ AT AMPERES A.F.F. ABOVE FINISH FLOOR ABOVE BLDG. BUILDING BRD. BOARD BOTTOM BEAM CAB. CABINET / CABINETS C1D1 CLASS 1, DIVISION 1 C1D2 CLASS 1, DIVISION 2 CLG. CEILING CLR. CLEAR COMP. COMPARTMENT CT.CIRCUIT DN. DOWN DECO. DECONTAMINATION DIA. DP. EA, DIAMETER DEEP / DEPTH D.W. DISH WASHER MACHINE (E) / EX.EXISTING EACH ELEC. ELECTRICAL ELEV. ELEVATION EQUIP. EQUIPMENT F.F. FRZ. FREEZER F.S. # SIZE QTY. TYPE TYPE REMARKS 1 6'-0" x 5'-0"1 FIXED ALUMINUM 1/2" THK. TEMPERED GLASS SIDELIGHT FOR DOORS (45 MIN RATED) X X X X X WINDOW SCHEDULE #BASE C1 GYP. BOARD F1 F2 CONCRETE VINYL FLOORING F3 CERAMIC TILE #BASE SCALE: 3/16" = 1'-0" # W1 BASE GYP. BOARD W2 EPS PANEL W3 VINYL COVING BASE WALL FINISH SCHEDULE FINISH (2) LAYERS OF ENAMEL PAINT, COLOR: _______ CODE: ______ BY: SHERWIN WILLIAMS OR EQUAL MOISTURE RESISTANT EXPANDED POLYSTYRENE (EPS) PANEL, COLOR: WHITE 3/8" MIN. COVING FLOORING BASE BOARD, COLOR: TO MATCH WALL FINISH FLOORING FINISH SCHEDULE FINISH (1) LAYER OF DB CLASSIC 9510 RESISTANT URETHANE OVER (1) LAYER OF DB CLASSIC 3300 EPOXY VINYL SHEET TYPE OF FLOORING BY: TRAFFIC MASTER, COLOR: REDWOOD ACACIA 20" SQ. CERAMIC TILE BY: EMSER TILE, SERIES: REALM, COLOR: REAL DOMAIN CEILING FINISH SCHEDULE FINISH (2) LAYERS OF ENAMEL PAINT, COLOR: _______ CODE: ______ BY: SHERWIN WILLIAMS OR EQUAL FINISH NOTES: 1) ALL MATERIAL USED AS INTERIOR TRIM SHALL HAVE A MINIMUM CLASS C FLAME SPREAD AND SMOKE-DEVELOPED INDEX SHALL NOT EXCEED 10% OF THE WALL OR CEILING AREA IN WHICH IT IS ATTACHED. 2) CURTAINS, DRAPERIES,FABRIC HANGINGS, AND SIMILAR COMBUSTIBLE DECORATIVE MATERIALS SUSPENDED FROM WALLS OR CEILINGS SHALL NOT EXCEED 10% OF THE WALL OR CEILING AREA TO WHICH SUCH MATERIALS AREA ATTACHED. SYMBOLS LEGEND & ABBREVIATIONS SYMBOL DESCRIPTION # # DENOTES KEYED NOTE NUMBER SEE KEYED NOTES LEGEND DENOTES DOOR NUMBER SEE DOOR SCHEDULE DETAIL NUMBER DESIGNATION PAGE NUMBER DESIGNATION VIEW DIRECTION OF INTERIOR ELEVATION SHEET NUMBER NUMBER OF INTERIOR ELEVATION DENOTES EQUIPMENT SPECIFICATION SEE EQUIPMENT SCHEDULE VIEW DIRECTION OF DETAIL / SECTION DETAIL NUMBER / SECTION NUMBER SHEET NUMBER INDICATES SIGNAGE TYPE AND LOCATION SEE ADA SIGNAGE INFORMATION THERMOSTAT FOR HVAC SYSTEM SEE MECHANICAL DRAWINGS FOR SPEC. INDICATES FINISH MATERIALS PER FINISH SCHEDULE ON SHEET A-5 INDICATES SECURITY DOOR EQUIPPED w/ CARD READER FOR ENTRY PERCENTAGE / PERCENT DIAMETER GRD. GRADE G.F.I. GROUND FAULT INTERRUPTER G.F.P. GROUND FAULT PROTECTION GYP. GYPSUM HI.HIGH HR. HT. J. HOUR / HOURS HEIGHT ELECTRICAL JUNCTION BOX LAV. LAVATORY LG.LENGTH MAX. MAXIMUM MIN. MINIMUM MTL. METAL NO. / # NUMBER O.H. OVER-HEAD PREP. PREPARING REF, RM. ROOM SPEC. SPECIFICATION(S) SYS. SYSTEM THK. THICK / THICKNESS TYP. TYPICAL V. WIDTH U.N.O. UNLESS NOTED OTHERWISE VENT FINISH FLOOR FINISH SURFACE G.C. GENERAL CONTRACTOR VTR. VENT THRU ROOF W.C. WATER CLOSET WD. W.H. WATER HEATER W.P. WATERPROOF YR.YEAR / YEARS ADA SIGNAGE INFORMATION MOUNTING HEIGHT FOR TACTILE SIGNAGE: SIGNS CAN NOW BE MOUNTED WITHIN A RANGE OF SPACE WHICH ALLOWS FOR A CONSISTENT TOP HEIGHT FOR DIFFERENT SIZED SIGNS ALONG A HALL. SIGNS ARE TO BE MOUNTED AT A HEIGHT TO ALLOW THE BASELINES OF RAISED CHARACTERS TO BE LOCATED BETWEEN 48" AND 60" ABOVE THE GROUND. MOUNTING LOCATION MUST ALLOW A PERSON TO APPROACH WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING PATH OF THE DOOR REFRIGERATOR MICRO. MICROWAVE REMARKS SEAL PRIOR INSTALLING COVE BASE BOARD MOISTURE, SCRATCH AND CUT RESISTANT 3/16" GROUT JOINT RECOMMENDATION REMARKS TEXTURE:________ SYMBOL WALL LEGEND DESCRIPTION 2x4 NON-BEARING IMP PANEL WALLS @ 48" O.C. TYP. 2x4 NON-BEARING STUD WALLS @ 16" O.C. TYP. EXISTING 2x6 PARTITION WALLS TO REMAIN EXISTING 2x4 PARTITION WALLS TO REMAIN INDICATING AREA OF 1-HOUR FIRE RATING REMARKS TEXTURE: SMOOTH AND WASHABLE SURFACE INSTALL PER MANUFACTURE'S INSTRUCTIONS 2 3 KEYED NOTES 1 COUNTER SURFACE TO BE 34" MAX. ABV. F.F. OCCUPANT LOAD SIGN TO BE POSTED IN A CONSPICUOUS PLACE NEAR ALL MAIN ENTRANCES (CBC 1008.1.9.) PROVIDE ABOVE DOOR SIGN LEGEND STATING - "DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" 4 FIRE EXTINGUISHER LOCATION (TYPICAL AS SHOWN) 5 EXISTING STRUCTURAL COLUMN TO REMAIN (TYPICAL) 7 PROPOSED "NO LOITERING OR SOLICITING" SIGNANGE PER CITY ORDINANCES AND STATE PENAL CODES 8 EXISTING FIRE ALARM PANEL X X MANUFACTURE AREA PRODUCT STORAGE OFFICE EMPLOYEE BREAK ROOM LOUNGE ROOM DELIVER OFFICECOMMON HALLWAY OFFICE RECEPTION A.R.R.1 N CORRIDOR A.R.R.2 RECEPTION 10'-7" X 19'-5" 9' CLG. W1 F2 C1 MANUFACTURE STOCK (LIMITED ACCESS) 11'-8" X 19'-5" 9' CLG. PRODUCT 16'-10" X 19'-5" 9' CLG. 9' CLG. 22'-8" X 17'-7" 9' CLG. 22'-9" X 38'-10" 13'-0" CLG. W1 F2 C4 45'-4" X 52'-10" 13'-0" CLG. W3 F2 C4 15'-7" X 8'-8" 9' CLG. 11'-0" X 14'-5" 9' CLG. 28'-6" X 10'-9" 9' CLG. 16'-0" CLG. W1 F1 C2 C2 OPEN CEILING OPEN CEILING, EXPOSED TO STRUCTURE PROPOSED FLOOR PLAN W2W1 W1 F2 C1 W1 F2 C1 W1 F2 C1 W1 F2 C1 W1 F2 C1 W1 F2 C1 W1 F2 C1 STORAGE EXIT EXIT EXIT EXIT EX I T EXIT EX I T EX I T EXIT (LIMITED ACCESS) 6'-10" X 7'-7" 9' CLG. W3 F2 C1W2W1 6'-10" X 7'-7" 9' CLG. W3 F2 C1W2 E1 E1 D3 E2 D3 D1 D1 D1 D1 D1 D1 E1 E1 E3 9'-0" x 9'-0"--2 EXISTING GARAGE ROLLER DOOR - MOTOR CLOSING - NO LATCHING DEVICE E3E3 52 ' - 1 0 " 22'-4"6"11'-7"6"21'-9"6" D2 D2 1 2S1 S1 S1 S2S2 S2 EXIT 2333 8 7 11'-4"10"11'5"28'-6" 4 9 5 9 PROPOSED WORK TABLE 7 S5 S5 S7S6S7S6 1 D3 6'-0" x 6'-10" 1-3/4"2 36" DOOR - SELF CLOSING - PANIC HARDWARE - NO SPECIAL KNOWLEDGE REQ. TO OPERATEH.C.M. SD - 2 5 SD - 1 SD - 1 11 SD-2 18 ' - 8 " 29 ' - 8 " 37'-11"5"7'5"22'-9"10'-7"11'-3"16'-10" 109'-3" 19 ' - 5 " 5" 5'- 6 " 12 ' - 6 " 6'- 3 " 8' - 9 " 6" W A L L 36 " W I N D O W H E I G H T 4" 1/2" THK. GYP. BOARD STEEL SLIDING FIRE WINDOWS, 3/4-HOUR I.C.B.O REPORT # 2781 OR EQUAL INTERLOCK STILE WINDOW JAMB WINDOW JAMB SLIDING PANEL FURNISHED w/ POSTITIVE LATCHING 1/8" THK. STEEL LATCH WINDOW DIMENSION PASS-THRU WINDOW SCALE: N.T.S. EQUIPPED w/ SPRING ACTIVATED AUTOMATIC CLOSERS 4" METAL STUD WALL @ 16" O.C. 1/2" THK. GYP. BOARD WINDOW SILL 1-1/8" FRAME AND SASH TO BE 16 GA. STEEL w/ 12 GA. GUSSETS & 16 GA. ANGLES WINDOW TO BE FACTORY GLAZED w/ CLEAR 1/4" THK. WIRE GLASS OR 3/16" THK. CLEAR FIRELITE. ANSI Z97.1 & ASTM C1036. INDIVIDUAL LITES SHALL NOT EXCEED 720 SQ. IN. WINDOW HEADER SINK 4 SD - 1 WALL TO BE ONE HOUR FIRE-RATED PR O P O S E D F L O O R P L A N I-KRUSHER 11818 CLARK ST, ARCADIA, CA 91006 ARCHITECT'S APPROVAL: 3'-9"1'-11" NO RACK STORAGE IN THIS PROJECT. SINGLE LAYER PALLET ON GROUND STORAGE ONLY. VERTICAL STORAGE BELOW 60 INCH HEIGHT. AISLES IN STORAGE AREA ARE KEEPING IN NOT LESS THAN 96 INCHES. STORED PRE-FILLED CARTRIDGES WITHOUT ANY OIL OR LIQUID IN STORAGE AREA. NON HAZARDOUS MATERIALS BEEN STORED. (CFC 5003.1.1) 10 11 12 MANUFACTURED FOR PACKAGING REBRAND PRODUCT ONLY. THE PRODUCT ARE PRE-FILLED CARTRIDGES WITHOUT ANY OIL OR LIQUID. 13 4'7'7'-5" 13 10 11 12 10 11 12 E:\IMG Space\Stamp\2026 GW STAMP 2.jpg 4" 4" E:\IMG Space\Stamp\2026 GW STAMP 2.jpg IMG SPACE SD - 2 I-KRUSHER 11818 CLARK ST, ARCADIA, CA 91006 IM P W A L L D E T A I L S 6 FOAM IN PLACE INSULATION FIELD CUT THERMAL BREAK (AS REQUIRED) IMP CEILING FOAM IN PLACE INSULATION IMP WALL 16 GA ANGLE CLOSURE TRIM TO MATCH IMP FINISH CONTINUOUS SEALANT FIELD CUT THERMAL BREAK HANGER ROD REQUIRED TO SUPPORT ANGLE WHERE CLOSEST CHANNEL HANGER IS GREATER THAN 4'-0" AWAY FROM WALL COUPLING 3/8" NUT & WASHER VAPOR BARRIER CONTINUOUS SEALANT IMP CEILING CLOSURE TRIM TO MATCH IMP FINISH IMP WALL CONTINUOUS SEALANT #10x3/4" TEK SCREWS AT 12" OC CONTINUOUS 26 GA TRIM BUTYL SEALANT BOTH SIDES OF TEE 4"x3"x3/16" EXTRUDED ALUMINUM CEILING TEE FILL 1/2" GAP BETWEEN PANEL WITH FOAM IN PLACE INSULATION #12 - 14x1-1/4" CAP SCREWS AT 30" OC BOTH SIDES 3/8" x 1-1/2" BOLT WITH(3) 3/8" WASHERS AND (1) LOCK-NUT PER BOLT 3/8" DIA EYE COUPLER NUT 3/8" HANGER ALL-THREAD ROD AT EVERY JOIST/BEAM LOCATION (NO GREATER THAN 6'-0" OC) HEX NUT AND LOCK WASHER 4"x4"x14 GA PLATE WASHER SELF-ADHERING VAPOR BARRIER FOUR TIGHT TURNS IN 1-1/2" SEISMIC BRACE PLATE 8 GA SPLAY BRACE WIRE IN FOUR DIRECTIONS 3/8" ALL-THREAD HANGER ROD SEISMIC BRACE PLATE (AS REQUIRED PER CODE) NOTE: SPACE ABOVE CEILING MUST BE VENTILATED IMP CEILING. EXTERIOR SIDE OF PANEL MUST BE ON BOTTOM OF CEILING 26 GA SNAP ON COVER OVER TEE (MATCH CEILING PANEL FINISH) ROD INSULATION, EXTEND 3'-0" ABOVE CEILING AT COOLER OR FREEZER CONDITIONS FOAM IN PLACE INSULATION IMP WALL 16 GA ANGLE CLOSURE TRIM TO MATCH IMP FINISH CONTINUOUS SEALANT FIELD CUT THERMAL BREAK HANGER ROD REQUIRED TO SUPPORT ANGLE WHERE CLOSEST CHANNEL HANGER IS GREATER THAN 4'-0" AWAY FROM WALL COUPLING 3/8" NUT & WASHER VAPOR BARRIER CONTINUOUS SEALANT IMP CEILING NUT AND STEEL BEARING WASHER 3/8" HANGER ALL-THREAD ROD EXISTING ROOF JOIST BOTTOM CHORD TYPICAL WALKABLE CEILING ROD CONNECTION SINGLE NUT AND STEEL BEARING WASHER NUT AND STEEL BEARING WASHER COORDINATE FINAL LOCATION WITH STRUCTURAL ENGINEER SINGLE NUT AND STEEL BEARING WASHER 3/8" HANGER ALL-THREAD ROD ESCUTCHEON SET IN FULL BED OF SEALANT IMP CEILING, SEE WALL TYPES SHEET JOINT SEALANT ALL AROUND, TYP CUSTOMER EQUIPMENT IMP JOINTS TYP. 4 IMP WALL TO IMP CEILING DET. FINISHED FLOOR 0' - 0" EXISTING ROOF +12'-6" 5 IMP CEILING PENETRATION 1 IMP WALL WINDOW FRAME 2 FRAMED OPENING SILL-OFF MODULE W/EXTRUSION MANUFACTURE AREA PRODUCT STORAGE METAL BOTTOM TRACK INSULATION CONCRETE SLAB CLOSURE TRIM TO MATCH IMP FINISH IMP WALL CONTINUOUS SEALANT WELDED PLATE SEE DETAIL ON ENLARGE IMP WALL BOTTOM PLATE 3 IMP WALL BOTTOM TRACK ENLARGE PLAN 4" IMP PANEL E:\IMG Space\Stamp\2026 GW STAMP 2.jpgE:\IMG Space\Stamp\2026 GW STAMP 2.jpg IMG SPACE SD - 3 I-KRUSHER 11818 CLARK ST, ARCADIA, CA 91006 IM P W A L L S P C E & N O T E S E:\IMG Space\Stamp\2026 GW STAMP 2.jpg THE MATERIAL USE FOR IMP WALL AND POST MUST MEET ASTM E119-2020