Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
101 E Foothill Blvd - 2026 - US Bank
OWNER ARCHITECT RSP Architects, Ltd. 1220 Marshall Street NE Minneapolis, MN 55413 Phone: (612)677-7100 Phylicia Vance, Project Contact Phone: (612) 677-7498 Email:phylicia.vance@rsparch.com US Bank Corporate Real Estate 4480 Emerald Avenue Cincinnati, OH 45242 Dan Pawlak, Vice President, Retail Design Manager Phone:(513) 794-8783 Email:daniel.pawlak@usbank.com PROJECT MANAGER JLL 45 South 7th Street, Suite 3051 Minneapolis, MN 55402 Nikki Sternin, Project Manager Phone: (952) 494-4264 Email: nikki.sternin@jll.com GENERAL AREA OF WORK NOT IN SCOPE LEGEND PROJECT NUMBER: CLIENT PROJECT NUMBER: CA - Arcadia, Arcadia Foothill 101 E Foothill Blvd, Arcadia, CA 91006 14854C5247 23424P4C5247 DRAWINGS ISSUES SHEET NO.NAME PE R M I T S E T - 0 3 / 1 9 / 2 0 2 5 PL A N R E V I E W C O M M E N T S - 0 9 / 1 9 / 2 0 2 5 PL A N R E V I E W C O M M E N T S - 1 1 / 1 3 / 2 0 2 5 PL A N R E V I E W C O M M E N T S - 1 2 / 1 7 / 2 0 2 5 GENERAL G000 COVER SHEET 1 2 2 2 G001 ABBREVIATIONS, DRAWING SYMBOLS, GENERAL NOTES 1 4 G101 FIRE AND LIFE SAFETY PLAN, CODE ANALYSIS 1 2 2 G201 UNRESASONABLE HARDSHIP EXCEPTION FORMS 1 2 ARCHITECTURAL SITE A001 ARCHITECTURAL SITE PLAN 1 2 2 A010 SITE DETAILS (CALIFORNIA)1 2 2 DEMOLITION D101 GROUND FLOOR DEMOLITION FLOOR PLAN 1 4 ARCHITECTURAL A101 GROUND FLOOR ARCHITECTURAL AND PVD PLAN 1 2 4 A901 INTERIOR ELEVATIONS 1 2 4 INTERIORS i101 GROUND FLOOR FINISH PLAN 1 4 i102 FINISH & FURNITURE SCHEDULES 1 4 i301 GROUND FLOOR FURNITURE PLAN 1 4 SPECIFICATIONS SPEC 01 SPECIFICATIONS 1 4 SPEC 02 SPECIFICATIONS 1 4 SPEC 03 SPECIFICATIONS 1 4 SPEC 04 SPECIFICATIONS 1 4 SPEC 05 SPECIFICATIONS 1 4 SPEC 06 SPECIFICATIONS 1 4 SPEC 07 SPECIFICATIONS 1 4 SPEC 08 SPECIFICATIONS 1 4 SPEC 09 SPECIFICATIONS 1 4 SPEC 10 SPECIFICATIONS 1 4 ELECTRICAL E000 ELECTRICAL GENERAL NOTES AND SYMBOLS 1 2 E001 ELECTRICAL SPECIFICATIONS 1 2 E101 ELECTRICAL POWER PLAN 1 ED101 ELECTRICAL DEMOLITION PLAN 1 PROJECT TEAM DOCUMENT PACKAGE SHEET INDEX ISSUED:03/19/2025 PACKAGE:PERMIT SET LOCATION MAP KEY PLAN SITE LOCATION PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 12/16/2025 7:59:30 AM 14854C5247 AWR CK PV 03/19/2025 C34974 12/17/2025 W. Scott Fay 11/30/2027 COVER SHEET G000 101 E Foothill Blvd, Arcadia, CA 91006 ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. ISSUE KEY: 1 - ISSUED (WITH SIGNATURE) 2 - REVISED AND RE-ISSUED (WITH SIGNATURE) 3 - NOT FOR CONSTRUCTION - REFERENCE ONLY 4 - RE-ISSUED FROM A PRIOR ISSUED SET- NO REVISIONS 5 - ISSUED (NO SIGNATURE) 6 - REVISED AND RE-ISSUED (NO SIGNATURE) CODE SUMMARY PLAN NORTH N TRUE NORTH TRUE NORTH PROJECT DESCRIPTION INTERIOR REMODEL FOR U.S. BANK OF THEIR EXISTING 3,710 GROSS SQUARE FOOT SINGLE-TENANT BUILDING. OCCUPANCY IS BUSINESS GROUP B AND IS UNCHANGED. TENANT AREA: 3,710 SF REMODELED AREA: 3,295 SF APPLICABLE CODES BUILDING CODE: 2022 CALIFORNIA BUILDING CODE (TITLE 24, PARTS 1 & 2) EXISTING BUILDING CODE: 2022 CALIFORNIA EXISTING BUILDING CODE (TITLE 24, PART 10) MECHANICAL CODE: 2022 CALIFORNIA MECHANICAL CODE (TITLE 24, PART 4) PLUMBING CODE: 2022 CALIFORNIA PLUMBING CODE (TITLE 24, PART 5) ELECTRICAL CODE: 2022 CALIFORNIA ELECTRICAL CODE (TITLE 24, PART 3) FIRE CODE: 2022 CALIFORNIA FIRE CODE (TITLE 24, PART 9) ENERGY CODE: 2022 CALIFORNIA ENERGY CODE (TITLE 24, PART 6) ACCESSIBILITY: 2022 CALIFORNIA BUILDING CODE; CHAPTER 11B REFER TO SHEET G101 FOR COMPLETE LIFE SAFETY PLAN AND CODE ANALYSIS. AREA OF WORK NO. DATE DESCRIPTION 1 09/19/2025 PLAN REVIEW COMMENTS 2 11/13/2025 PLAN REVIEW COMMENTS 3 12/17/2025 PLAN REVIEW COMMENTS 1 ISSUED:09/19/2025 PACKAGE:PLAN REVIEW COMMENTS ISSUED:11/13/2025 PACKAGE:PLAN REVIEW COMMENTS 2 ISSUED:12/17/2025 PACKAGE:PLAN REVIEW COMMENTS W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEECCTIL 11/30/2027 ABV. ABOVE A.F.F. ABOVE FINISH FLOOR ACC. PNL.ACCESS PANEL ACOUS. ACOUSTICAL A.C.T. ACOUSTICAL CEILING TILE ADD. ADDENDUM ADD'N(L) ADDITION(AL) ADJ. ADJACENT ALT. ALTERNATE ALUM. ALUMINUM ANCH. ANCHOR(AGE) ANOD. ANODIZED & AND "L" ANGLE ANTQ. ANTIQUE APT. APARTMENT APPVD. APPROVED ARCH. ARCHITECT OR ARCHITECTURAL @ AT ART. ARTWORK ATT. ATTACH(ED) (MENT) AVG. AVERAGE A B. BASE MATERIAL BM. BEAM BRG. BEARING B.MK. BENCH MARK BTWN. BETWEEN BLK. BLOCK BLKG. BLOCKING BD. BOARD BOT. BOTTOM BRKT. BRACKET BRNZ. BRONZE BLDG. BUILDING B.S. BUILDING STANDARD B.BD. BULLETIN BOARD B CAB. CABINET CPT. CARPET CSWRK. CASEWORK C.I.P. CAST IN PLACE CALK. CAULKING CLG. CEILING CEM. CEMENT CTR. CENTER C.L. CENTER LINE C.T. CERAMIC TILE C.BD. CHALK BOARD CH. CHAIR CR. CHROMIUM, CHROME CIRC. CIRCLE, CIRCULAR CIRCUMFERENCE C.O. CLEANOUT CLR. CLEAR CLR.OPG.CLEAR OPENING CLO. CLOSET CLS. CLOSURE C.W. COLD WATER COL. COLUMN COMP. COMPRESSIBLE COMPR. COMPOSITE CONC. CONCRETE CMU. CONCRETE MASONRY UNIT CONF. CONFERENCE CONST. CONSTRUCTION CONT'D. CONTINUED CONT. CONTINUOUS CONTR. CONTRACTOR CONTRACT C.J. CONTROL JOINT COR. CORNER C.G. CORNER GUARD CORR. CORRIDOR CORRUG. CORRUGATED CSS CUSTOMER SERVICE STATION CTR. COUNTER CRED. CREDENZA C DEM. DEMOLITION DMT. DEMOUNTABLE DET. DETAIL DIAG. DIAGONAL DIA. DIAMETER DIM. DIMENSION DISP. DISPENSER DISPOS. DISPOSAL (or DISPOSER) DIST. DISTANCE DIV. DIVISION DR. DOOR D.O. DOOR OPENING DBL. DOUBLE DN. DOWN DRAP. DRAPERY DWR. DRAWER DW. DRYWALL D.F. DRINKING FOUNTAIN D EA. EACH E. EAST ELEC. ELECTRIC E.W.C. ELECTRIC WATER COOLER ELEV. ELEVATION ELEVR. ELEVATOR EMER. EMERGENCY ENCL. ENCLOSURE ENGR. ENGINEER ENTR. ENTRANCE EQ. EQUAL EQUIP. EQUIPMENT EXH. EXHAUST EXIST. EXISTING EXPAN. EXPANSION E.J. EXPANSION JOINT EXT. EXTERIOR EX. EXISTING E F F.O.F. FACE OF FINISH F.O.S. FACE OF STUD F.O.W. FACE OF WALL F-F FACE TO FACE FAS. FASTEN, FASTENER FIN. FINISH(ED) F.F. FINISH FLOOR F.A. FIRE ALARM F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET F.H.C. FIRE HOSE CABINET F.H.R. FIRE HOSE RACK F.P. FIREPROOFING FRT. IRE RETARDANT FIX. FIXED FIXT. FIXTURE FLEX. FLEXIBLE FLR. FLOOR F.D. FLOOR DRAIN F. MTD. FLOOR MOUNTED FLOUR. FLUORESCENT FL. FLUSH FT. FOOT OR FEET FTG. FOOTING FDN. FOUNDATION FRM. FRAME FRMG. FRAMING F.S. FULL SIZE(SCALE) FURN. FURNITURE F.B.O. FURNISHED BY OTHERS FUR. FURRED FURR. FURRING FUT. FUTURE G GA. GAGE, GAUGE GALV. GALVANIZED GEN. GENERAL GL. GLASS OR GLAZED G.B. GRAB BAR GRD. GRADE GRND. GROUND GT. GROUT GYP. GYPSUM GYP. BD. GYPSUM BOARD HNDRL. HANDRAIL HDBD. HARDBOARD HDWR. HARDWARE HDWD. HARDWOOD HD. HEAD HTG. HEATING HVAC HEATING VENTILATING AND AIR CONDITIONING HT. HEIGHT H.C. HOLLOW CORE HORIZ. HORIZONTAL H.W. HOT WATER HR. HOUR ICS INFANT CHANGING STATION INCAN. INCANDESCENT INCL. INCLUDE(D)(ING) INFO. INFORMATION I.D. INSIDE DIAMETER INSUL. INSULATION INT. INTERIOR INTM. INTERMEDIATE INV. INVERT JAN. JANITOR JAN. CLO. JANITOR CLOSET JNT. JOINT JTFILL JOINT FILLER JST. JOIST J.B. JUNCTION BOX K.P. KICK PLATE KIT. KITCHEN K.O. KNOCKOUT LAB. LABORATORY LAM. LAMINATE LG. LARGE LAV. LAVATORY L.H. LEFT HAND L.H.R. LEFT HAND REVERSE L. LENGTH LT LIGHT LTWT. LIGHT WEIGHT LTL. LINTEL LKR. LOCKER LOUV. LOUVER(S) LB. POUND MACH. MACHINE MAINT. MAINTENANCE MGR. MANAGER MFGR. MANUFACTURE(ER) MATL. MATERIAL MAX. MAXIMUM MECH. MECHANICAL MED. MEDIUM MET. METAL MEZZ. MEZZANINE MLWK. MILLWORK MIN. MINIMUM MIR. MIRROR MISC. MISCELLANEOUS MTD. MOUNTED MUL. MULLION NAT. NATURAL NEG. NEGATIVE NOM. NORMAL N. NORTH N.I.C. NOT IN CONTRACT N.T.S. NOT TO SCALE NO. NUMBER OFF. OFFICE OPNG. OPENING OPP. OPPOSITE O.H. OPPOSITE HAND ORIG. ORIGINAL OZ. OUNCE O.D. OUTSIDE DIAMETER OTOO OUT TO OUT OVHD. OVERHEAD O.HD. OVERHEAD DOOR O.C. ON CENTER PTD. PAINTED PR. PAIR PNL. PANEL P.T.D. PAPER TOWEL DISPENSER PTN. PARTITION PERM. PERMANENT PERP. PERPENDICULAR PLAS. PLASTER P.LAM. PLASTIC LAMINATE PL. PLATE PL.GL. PLATE GLASS PLBG. PLUMBING PLYWD. PLYWOOD PT. POINT POL. POLISH PORT. PORTABLE PSF. POUNDS PER SQUARE FOOT PREFAB. PREFABRICATED PROD. PRODUCTION, PRODUCT PROJ. PROJECT PROP. PROPERTY QUAL. QUALITY QUAN. QUANTITY Q.T. QUARRY TILE RAD. RADIUS RECEP. RECEPTACLE REF. REFERENCE RE: REFER TO REFL. REFLECTED REFR. REFRIGERATOR REINF. REINFORCED REM. REMAINDER REMV. REMOVE REQD. REQUIRED RESIL. RESILIENT R.B. RESILENT BASE R/A RETURN AIR REV. REVISION R.H. RIGHT HAND R.H.R. RIGHT HAND REVERSE RM. ROOM R.O. ROUGH OPENING RND. ROUND SAN. SANITARY S.N.D. SANITARY NAPKIN DISPENSER SC. SCALE SCHED. SCHEDULE SCHEM. SCHEMATIC SEAL. SEALANT SECT. SECTION SERV. SERVICE SHT. SHEET SIM. SIMILAR SPKR. SPEAKER SPEC'L. SPECIAL SPECS. SPECIFICATIONS SQ. SQUARE SF. SQUARE FEET SQ. IN. SQUARE INCHES STAG. STAGGERED S.S. STAINLESS STEEL STD. STANDARD STL. STEEL STOR. STORAGE STRUCT. STRUCTURAL SUP. SUPPLY SUPPORT SUSP. SUSPEND(ED) SYMM. SYMMETRICAL SYST. SYSTEM SCWD. SOLID CORE WOOD T.BD. TACKBOARD TEL. TELEPHONE T.V. TELEVISION TEMPD. TEMPERED TEMP. TEMPORARY THRESH. THRESHOLD T.P.H. TOILET PAPER HOLDER T.O.W. TOP OF WALL T.B. TOWEL BAR T.D. TOWEL DISPENSER TYP. TYPICAL U.L. UNDERWRITERS LABORATORY U.C. UNDERCUT UNFIN. UNFINISHED U.N.O. UNLESS NOTED OTHERWISE UTIL. UTILITY VAR. VARIABLE VNR. VENEER V.I.F. VERIFY IN FIELD VERT. VERTICAL VEST. VESTIBULE VIN. VINYL SHEET GOODS V.B. VINYL BASE V.C.T. VINYL COMPOSITION TILE V.W.C. VINYL WALL COVERING WSCT. WAINSCOT WH. WALL HUNG WC. WATER CLOSET W.H. WATER HEATER W.R. WATER RESISTANT W.P. WATERPROOF W.S. WEATHER-STRIPPING WT. WEIGHT W. WEST W.S.P. WET STANDPIPE WDW. WINDOW WDWALL WINDOW WALL W.GL. WIRE GLASS W/ WITH W/IN WITHIN W/O WITHOUT WD. WOOD WB WHITE BOARD W.B. WOOD BASE X TIMES OR BY (AS IN 2X4) YD. YARD & AND @ AT CENTERLINE ' FEET " INCHES (OR DITTO) #5 NUMBER ("NUMBER 5") PER ("POUNDS/FOOT") _ PERPENDICULAR 5# POUNDS ("5 POUNDS" H I J K L M N O P Q R S V W X Y MISC. ABBREVIATIONS Note: Not all abbreviations listed below are necessarily used in the drawings; refer elsewhere for abbreviations related to product or material codes. T U 0 ELEVATION / LEVEL TAG REVISION REFERENCE MATCH LINE SEE X/XXX MATCH LINE PARTITION TAG TO FOOTING EL= 96'-0" DRAWING TITLE NORTH ARROW A101 1 SIM 1 A101 SIM ELEVATION TAG - SINGLE VIEWA101 1 ELEVATION TAG - MULTIPLE VIEWA101 2 DETAIL TAG WALL SECTION TAG 1 A101 SIM BUILDING SECTION TAG ENLARGED PLAN OR DETAIL REFERENCE A101 1 SIM ROOM TAG KEYNOTE 23 WINDOW TAG EQUIPMENT TAG DOOR TAG FINISH TAG - WITH EXTENT OF FINISH FINISH TAG - ALL SURFACES FINISH TRANSITION 12 VIEW NAME 1/8" = 1'-0" EL= 100'-0"SPOT ELEVATION 0 COLUMN OR GRID LINE - NEW COLUMN OR GRID LINE - EXISTING (WALL FINISH) (BASE FINISH) (FLOOR FINISH) (ROOM NAME) (ROOM NUMBER) (ROOM AREA) 1 1 1t MATERIAL TAG ROOM NAME 101 101 CPT-1 TL-8 1t 1'-0" A1 CEILING TAG PLAN NORTH N TRUE NORTH PT-1B VB-3 CPT-2 TL-7 XXXX 48" AFF LAM-2 FW FIRE EXTINGUISHER WALL MOUNTED 4' - 0 " DRAWING SYMBOLS PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:29:45 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 ABBREVIATIONS, DRAWING SYMBOLS, GENERAL NOTES G001 101 E Foothill Blvd, Arcadia, CA 91006NOTE: INFORMATION HERE IS FOR REFERENCE ONLY. ANY DIMENSIONS, NOTES, OR TEXT ON ARCHITECTURAL PLANS OVERRIDES THE INFORMATION FOUND ON THIS SHEET. GENERAL NOTES -PROJECT A. BUILDING AND SITE ELEMENTS LABELED AS EXISTING ARE TO REMAIN, UNO. B. MAINTAIN ALL EXISTING RATED WALL ASSEMBLIES. NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 FE-E FE-E FE-E ACCESSI BLE ACCESSI BLE SD VAULT 111CASH SAFE 112 MECH/NER 113 SD VAULT CIRCULATION 107 COUPON ROOM 110 COUPON ROOM 109 ATM / NIGHT DROP 106 CONFERENCE 120 WOMEN'S RESTROOM 117 MEN'S RESTROOM 118 BREAKROOM 114 CIRCULATION 116 TELLER LINE 108 ATM 103 ENTRY 101 WAITING 104 LOBBY 102 ENTRY 105 PLATFORMS 121 PLATFORMS 119 STORAGE 115 EXIT ACCESS TRAVEL DISTANCE: 99' -6" MAXIMUM: 100' -0" EXIT ACCESS TRAVEL DISTANCE: 64' -7" MAXIMUM: 100' -0" NO EXIT HEIGHT AND NUMBER OF STORIES: Allowable Height:3 Stories, 55 Feet Actual Stories:1 Stories (Existing, No Change) ALLOWABLE FLOOR AREA: Allowable Floor Area:23,000 SF Actual Floor Area:3710 SF (Existing, No Change) FIRE RESISTIVE REQUIREMENTS: Types I and II are those types of construction in which the building elements listed in Table 601 are of noncombustible materials. Table 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (hours) BUILDING ELEMENT TYPE IIB Structural frame 0 Bearing walls 0 Exterior 0 Interior 0 Nonbearing walls and partitions 0 Exterior 0 (per table 602) Interior 0 Floor construction 0 Roof construction 0 Note: Section 508.2.4 no separation is required between accessory occupancies and the main occupancy. INTERIOR FINISH REQUIREMENTS: Non-Sprinklered Building, B-Occupancy Exit Stairways, Ramps and Passageways: A Corridors and Exit Access Enclosures: B Rooms and Enclosed Spaces: C SEISMIC DESIGN Seismic Design Category: D EXITING REQUIREMENTS: Occupant Load Factors (OLF):150 -B occupancy (Office/Lobby/Tellers/Waiting) Occupant Load per occupancy: B occupancy: 3710 SF / 150 = 25 Occupants Total = 25 Occupants EXIT ACCESS: Required Provided Ground Floor 1 2 Exit Access Travel Distance:100 feet (B occupancy) Corridor Fire-Resistance Rating:1 hours (Non -Sprinklered) (Table 1020.2)(B occupancy, occupant load less than 30) Dead Ends:20 feet (B occupancy) Portable Fire Extinguishers : Fire Extinguishers for Class A Fire Hazards: Maximum floor area for extinguisher: 11,250 SF Maximum travel distance to extinguisher:75 feet PROJECT DESCRIPTION: Partial interior remodel of an existing occupied Business office function. No change in use. No change in occupancy. No exterior work. OCCUPANCY: Existing:B occupancy -Office/Lobby/Tellers/Waiting TYPE OF CONSTRUCTION: Existing:Type IIB, Non-Sprinklered. Assumed. CODE ANALYSIS PLUMBING CALCULATION: No change in area or occupancy, no change to existing plumbing counts. PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:29:49 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 FIRE AND LIFE SAFETY PLAN, CODE ANALYSIS G101 101 E Foothill Blvd, Arcadia, CA 91006 1/4" = 1'-0"1 GROUND FLOOR FIRE AND LIFE SAFETY PLAN PLAN NORTH N ACCESSIBILITY UPGRADES AS PART OF THE PROJECT • REGRADING / RESTRIPING OF PARKING LOT DESIGNATED ACCESSIBLE STALL AISLE • ENTRANCE DOOR ACCESSIBLE HARDWARE • ACCESSILE PARKING STALL SIGNAGE CEBC 2022 SECTION 301.3 LEGEND -LIFE SAFETY EXISTING PARTITION TO REMAIN WALLS: EGRESS PATH OF TRAVEL ILLUMINATED EXIT SIGNS ACCESSIBLE EXIT EXISTING (E) NEW OR EXISTING WALL MOUNTED FIRE EXTINGUISHERFE-# NO. DATE DESCRIPTION 1 09/19/2025 PLAN REVIEW COMMENTS 2 11/13/2025 PLAN REVIEW COMMENTS ACCESSIBILITY UPGRADE VALUATIONS ACCESSIBILITY UPGRADES AT PRIMARY ENTRANCE TO THE BUILDING OR FACILITY COST DEMOLITION AND REMOVAL OF EXISTING ASPHALT $ 3,500.00 GRIND & OVERLAY ASPHALT $ 5,501.00 SAWCUT, DEMOLITION AND REMOVAL OF EXISTING CONCRETE $ 6,550.00 CONCRETE POURBACK $ 8,721.00 ACCESSIBLE PARKING STALL SIGNAGE $ 1,500.00 ACCESSIBLE PARKING STALL AND ACCESS AISLE RE-STRIPE $ 3,500.00 ACCESSIBLE DOOR HARDWARE AT BUILDING ENTRANCE $ 5,743.00 TOTAL: $ 35,015.00 CONSTRUCTION VALUATION: $ 169,327.66 x 20% = $ 33,865.53 MATERIAL + LABOR 1 2 W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 12/16/2025 7:59:31 AM 14854C5247 MACL MACL 11/13/2025 C34974 12/17/2025 W. Scott Fay 11/30/2027 UNRESASONABLE HARDSHIP EXCEPTION FORMS G201 101 E Foothill Blvd, Arcadia, CA 91006 NO. DATE DESCRIPTION 2 11/13/2025 PLAN REVIEW COMMENTS 3 12/17/2025 PLAN REVIEW COMMENTS 2 3 W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEECCTIL 11/30/2027 This point is at 0,0. Put the lowerleft grid intersection of your floorplan or the lower left corner ofany other type of drawing here. HI G H L A N D O A K S D R I V E E FOOTHILL BLVD AS6 1 1 V A N AC C E S S I B L E SP A C E 1 V A N AC C E S S I B L E SP A C E 5 P A R K I N G S P A C E S 4 P A R K I N G S P A C E S 2 P A R K I N G SP A C E S 13 PARKING SPACES 12 P A R K I N G S P A C E S AS4 AS4 2 AS8 AS4 3 4 4 5 6 6 EX. 3' - 0" EX . 3' - 0 " PARKING COUNT VAN ACCESSIBLE SPACES TOTAL PARKING STALLS 02 38 PLAN LEGEND ACCESSIBLE ROUTE FROM PARKING TO BUILDING ENTRY EXIT ONLY ACCESSIBLE ROUTE TO PUBLIC WAY KB KNOX BOX (IF REQUIRED) FSR FIRE SPRINKLER ROOM ACCESS (IF REQUIRED) ACCESSIBLE BUILDING ENTRY BUILDING ENTRY PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:29:55 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 ARCHITECTURAL SITE PLAN A001 101 E Foothill Blvd, Arcadia, CA 91006 3/32" = 1'-0"1 ARCHITECTURAL SITE PLAN PLAN NORTH N KEYNOTES - SITE PLAN NO. DESCRIPTION ARCHITECTURAL 1 DASHED LINE INDICATES OVERHANG ABOVE. 2 CROSSHATCH INDICATES ASPHALT TO BE REGRADED AT ACCESSIBLE PARKING ACCESS AISLE TO MEET ACCESSIBLE CODE STANDARDS. MILL EXISTING ASPHALT PAVEMENT, 2" AT EDGES AND ROUGHEN ON CENTER. OVERLAY ASPHALT PAVEMENT TO PROVIDE SLOPE OF NOT MORE THAN 1:48 (2%). 3 RESTRIPE ACCESSIBLE PARKING STALL AND ACCESS AISLE AS REQUIRED AT NEW ASPHALT. 4 EXISTING TRUNCATED DOMES PER DETAILS 5/A010 AND 6/A010. 5 EXISTING ZERO CURB. 6 EXISTING CURB RAMP AND GROOVES. REFER TO DETAIL 7/A010 FOR ADDITIONAL INFORMATION. ACCESSIBILITY SITE SIGNAGE (BY OWNER'S SIGN VENDOR) AS1 INTERNATIONAL SYMBOL OF ACCESSIBILITY POST MOUNTED (FROM PUBLIC WAY TO BUILDING ENTRY) AS2 INTERNATIONAL SYMBOL OF ACCESSIBILITY BUILDING MOUNTED (FROM PUBLIC WAY TO BUILDING ENTRY) AS3 SIGNAGE DIRECTING TO ACCESSIBLE ENTRY (AT NON-ACCESSIBLE DOOR) AS4 TOW AWAY SIGNAGE. REFER TO DETAIL 4/A010 FOR ADDITONAL INFORMATION. AS5 ACCESSIBLE STALL SIGN - POST MOUNTED AS6 VAN ACCESSIBLE STALL SIGN - POST MOUNTED. REFER TO DETAIL 3/A010 FOR ADDITONAL INFORMATION. AS7 ACCESSIBLE STALL SIGN - BUILDING MOUNTED AS8 VAN ACCESSIBLE STALL SIGN - BUILDING MOUNTED. REFER TO DETAIL 3/A010 FOR ADDITONAL INFORMATION. GENERAL NOTES -SITE PLAN A. REFER TO CIVIL DRAWINGS FOR ADDITIONAL INFORMATION. B. ACCESSIBILITY SURVEY COMPLETED ON 7/23/2024 C. REFER TO OWNERS SIGNAGE VENDOR DRAWINGS FOR SITE ACCESSIBILITY SIGNAGE. SUBMITTED UNDER SEPARATE PERMIT SUBMISSION. D. REFER TO OWNERS SIGNAGE VENDOR DRAWINGS FOR SITE AND BUILDING SIGNAGE. SUBMITTED UNDER SEPARATE PERMIT SUBMISSION. E. TO THE BEST OF OUR KNOWLEDGE, THE EXISTING PATH OF TRAVEL FROM STREET SIDEWALK AND EXISTING ACCESSIBLE PARKING STALLS TO THE BUILDING ENTRANCE COMPLIES WITH THE 2018 WASHINGTON STATE BUILDING CODE, CHAPTER 11 F. TO THE BEST OF OUR KNOWLEDGE, NO ABRUPT CHANGES IN ELEVATION EXIST ALONG THE PATH OF TRAVEL AND THE SLOPE AND CROSS-SLOPE ALONG THE PATH OF TRAVEL DOES NOT EXCEED 5% AND 2% RESPECTIVELY. G. 8'-2" CLEAR VERTICAL CLEARANCE PROVIDED FOR ACCESSIBILITY TO ACCESSIBLE PARKING. H. UNO, ALL PARKING STALLS AND SIGNAGE ARE EXISTING. TO THE BEST OF OUR KNOWLEDGE, EXISTING STALLS AND SIGNAGE COMPLY WITH CURRENT REQUIREMENTS SHOWN ON THIS SHEET. I. SMOKING IS PROHIBITED WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR INTAKES AND OPERABLE WINDOWS WHERE OUTDOOR AREAS ARE PROVIDED FOR SMOKING, AND IN BUILDINGS. J. IF EXISTING ELEMENTS ARE FOUND TO BE NON-COMPLIANT, PROVIDE NEW ELEMENTS COMPLYING WITH CURRENT REQUIREMENTS SHOWN ON THIS SHEET. K. ACCESSIBLE ROUTES TO BE VERIFIED IN THE FIELD FOR COMPLIANCE WITH ACCESSIBLE REQUIREMENTS. L. LANDSCAPING TO BE SHAPED TO PROVIDE USE OF SIDEWALKS AND VISIBILITY OF SIGNAGE AND THROUGH WINDOWS TRUE NORTH N NO. DATE DESCRIPTION 1 09/19/2025 PLAN REVIEW COMMENTS 2 11/13/2025 PLAN REVIEW COMMENTS 1 1 1 1 2 2 W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 AL I G N W I T H E N D O F P A R K I N G S T A L L WHITE PAINTED LOGO ON DARK BLUE BACKGROUND 2" WIDE BLUE LINES OF PARKING STALL OR WITHIN 6" ACCESS AISLE TO BE MARKED WITH BLUE PAINTED BORDER PER CBC 11B-502.3.3 70 SQ. IN. (MIN) REFLECTORIZED PARKING IDENTIFICATION SIGNS PER CBC 11B-502.6 SEE DETAIL AND FOR ADDITIONAL INFORMATION, TYP WHEEL STOP, TYP STRIPING AT 36" (MAX) O.C. IN A COLOR CONTRASTING W/ AISLE SURFACE (BLUE OR WHITE) SYMBOL PER CBC 11B-502.3.3 12" (MIN) HIGH "NO PARKING" TO BE PAINTED WHITE WITHIN STRIPED LOADING AREA AT ACCESSIBLE AND VAN ACCESSIBLE SPACES PER CBC 11B-502.3.3 TYPICAL PAVEMENT SYMBOL PER CBC 11B-502.6.4 SEE DETAIL TYPICAL PAVEMENT SYMBOL PER CBC 11B-502.6.4 SEE DETAIL NO PARKING (9'-0 ALTERNATE) 12' - 0"9' - 0" 18 ' - 0 " 5' - 0 " (VAN) 8'-0" MIN AT 9'-0" ALTERNATE 5' - 0" /2 A010 /2 A010 /3 A010 /---- VAN ACCESSIBLE WHITE PAINTED LOGO ON DARK BLUE BACKGROUND. PROVIDE ONE SIGN FOR EACH DISABLED PARKING SPACE SIGN SHALL STATE "MINIMUM FINE $250" PER CBC 11B-502.6.2 WHITE PAINTED LETTERS ON DARK BLUE BACKGROUND. PROVIDE AT VAN PARKING SPACES ONLY STD 2" DIA GALV STEEL POLE WITH 2'-0" EMBEDMENT IN CONCRETE. ATTACH SIGN TO POLE WITH GALV STRAPS AT TOP AND BOTTOM SIGN SHALL BE REFLECTORIZED WITH A MINIMUM AREA OF 70 SQ IN 80 " M I N UNAUTHORIZED VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNERS EXPENSE. TOWED VEHICLES MAY BE RECLAIMED AT OR BY TELEPHONING MATERIALS: REFLECTORIZED PAINT OR PORCELAIN ON METAL 1" MIN HIGH WHITE LETTERS ON BLACK BACKGROUND STD 3" DIA GALV STEEL POLE WITH 2'-0" EMBEDMENT IN CONCRETE. ATTACH SIGN TO POLE WITH GALV STRAPS AT TOP AND BOTTOM INSTALL IN A CONSPICUOUS LOCATION AT EACH ENTRANCE TO OFF-STREET PARKING FACILITIES OR IMMEDIATELY ADJACET TO ON-SITE ACCESSIBLE PARKING IN A LOCATION VISIBLE FROM EACH PARKING SPACE 3' - 6 " M I N 1 ' - 1 0 " M I N 1' - 5" MIN BLANK SPACES SHALL BE FILLED IN WITH APPROPRIATE INFORMATION AS A PERMANENT PART OF THE SIGN TRUNCATED DOMES. 3'-0" MIN IN DIRECTION OF TRAVEL. FOR DOME SPACING SEE EXISTING SIDEWALK, 4'-0" MINIMUM ACCESS AISLE /5 A010 EXISTING PAVING Slope DN. 1:12 MAX. EXISTING CURB EXISTING CURB RAMP. FIELD VERIFY FOR ACCESSIBILITY COMPLIANCE TRENCH TRENCH TRENCHING PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:29:57 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SITE DETAILS (CALIFORNIA) A010 101 E Foothill Blvd, Arcadia, CA 91006 12" = 1'-0"2 ACCESSIBLE PARKING SYMBOL (California) 1/8" = 1'-0"1 ACCESSIBLE PARKING (California) NO. DATE DESCRIPTION 1 09/19/2025 PLAN REVIEW COMMENTS 2 11/13/2025 PLAN REVIEW COMMENTS 3/4" = 1'-0"3 PARKING IDENTIFICATION SIGNAGE 1" = 1'-0"4 ADDITIONAL SIGNAGE AT PARKING LOT ENTRANCE(S) 12" = 1'-0"5 TRUNCATED DOME 1/4" = 1'-0"6 SITE - TRUNCATED DOMES AT FLUSH SIDEWALK 1 1" = 1'-0"7 SITE - ACCESSIBLE RAMP SECTION 2 12" = 1'-0"8 TRENCHING DETAIL 2 W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 D1 D1 D2 D3 D4 D4 D5 D5 TYP. TYP. D6 D7 D10 D10 D10 D10 D10 D10 D11 D11 D13 D14 D12 D8 D9 D3 D3 D3 D3 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:29:58 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 GROUND FLOOR DEMOLITION FLOOR PLAN D101 101 E Foothill Blvd, Arcadia, CA 91006 KEYNOTES - DEMOLITION NO. DESCRIPTION D1 REMOVE EXISTING CASEWORK IN ITS ENTIRETY. PATCH AND REPAIR WALL AND FLOOR. PREPARE FOR NEW FINISHES. D2 REMOVE EXISTING CHECK STAND IN ITS ENTIRETY. PATCH AND REPAIR FLOOR AND PREPARE FOR NEW FINISHES. D3 REMOVE EXISTING PLASTIC LAMINTATE FINISH AND DOOR STOP FROM ALL SURFACES OF EXISTING DOOR. SEE ELEVATIONS ON A901 FOR MORE INFORMATION. D4 REMOVE EXISTING PLASTIC LAMINTATE FINISH FROM ALL SURFACES OF EXISTING TELLER LINE INCLUDING BASE CABINETS, PRIVACY BOXES, AND SUPPORTS. ALL EXISTING UNDERCOUNTER STEEL TO REMAIN. PREPARE SUBSTRATE TO LIKE NEW CONDITION TO RECIEVE NEW FINISH. REFER TO ELEVATIONS AND FINISH PLAN FOR ADDITIONAL INFORMATION. D5 REMOVE EXISTING COUNTERTOP. EXISTING MILLWORK BASE AND UNDERCOUNTER STEEL TO REMAIN. PATCH AND REPAIR WALL AS REQUIRED FOR LIKE NEW FINISH. D6 REMOVE EXISTING PLASTIC LAMINATE FINISH FROM ALL SURFACES OF EXISTING CASEWORK INCLUDING COUNTERTOP, BASE CABINETS, AND SUPPORTS. PREPARE SUBSTRATE TO LIKE NEW CONDITION TO RECIEVE NEW FINISH. REFER TO FINISH PLAN FOR ADDITIONAL INFORMATION. D7 REMOVE EXISTING FIRE EXTINGUISHER AND SALVAGE FOR RELOCATION, REFER TO ARCHITECTURAL PLAN FOR NEW LOCATION. D8 EXISTING WALL BASE AND FLOOR FINISHES TO REMAIN. PROTECT FROM DEMOLITION/CONSTRUCTION. D9 EXISTING MILLWORK TO REMAIN, REMOVE EXISTING VINYL BASE AND PREPARE SUBSTRATE TO RECEIVE NEW WALL BASE. D10 REMOVE EXISTING LAMINATE FINISH AT WALLS. PATCH AND REPAIR SUBSTRATE TO LIKE TO CONDITION IN ORDER TO RECEIEVE NEW LAMINATE FINISH. SEE ARCHITECTURAL SHEET FOR FINISH INFORMATION. D11 REMOVE EXISTING COUNTERTOP. PATCH AND REPAIR SUBSTRATE AND PREPARE FOR NEW FINISHES. D12 REMOVE EXISTING CEILING POWER POLE. REMOVE CABLING BACK TO SOURCE. D13 EXISTING BULLET RESISTANT GLASS AND PASS THRU TRAYS TO REMAIN. PROTECT FROM DEMOLITION/CONSTRUCTION D14 REMOVE BASE STORAGE AND PLAM APRON AT NEW TCR LOCATION. LEGEND -DEMOLITION EXISTING PARTITION TO REMAIN EXISTING PARTITION TO BE REMOVED NOT IN SCOPE EXISTING DOOR AND FRAME TO REMAIN EXISTING DOOR AND FRAME TO BE REMOVED EXISTING DOOR, FRAME, AND SIDELIGHT TO BE REMOVED PLAN NORTH N 1/4" = 1'-0"1 GROUND FLOOR DEMOLITION FLOOR PLAN GENERAL NOTES -DEMOLITION A. THE FOLLOWING PLANS REFLECT DEMOLITION INTENT ONLY. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DRAWINGS AND SHALL INCLUDE RELATED MECHANICAL, ELECTRICAL AND LIFE SAFETY SYSTEMS. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE WITH THE CONTRACT DRAWINGS. SEE SPECIFICATIONS FOR FURTHER INSTRUCTIONS. B. FIRE SAFETY MUST BE MAINTAINED FOR ALL PERSONNEL WORKING ON THE FLOOR. ALL EGRESS ROUTES, ALARMS, SPEAKERS, ETC. MUST REMAIN ACCESSIBLE AND OPERABLE AT ALL TIMES. IMMEDIATELY NOTIFY BUILDING SECURITY AND BUILDING MANAGER OF DAMAGED OR DISABLED SYSTEMS AND REPAIR OR REPLACE DAMAGED SYSTEMS IMMEDIATELY. C. UNUSUALLY LOUD DEMOLITION WORK (I.E. CONCRETE REMOVAL) SHALL BE COORDINATED WITH THE BUILDING MANAGER TO MINIMIZE DISRUPTION TO BUILDING OCCUPANTS. D. ALL DOORS, FRAMES, HARDWARE, MECHANICAL ITEMS, PLUMBING FIXTURES, LIGHT FIXTURES (INCLUDING DOWN LIGHTS & FLUORESCENT), AND SPECIAL EQUIPMENT SHOWN TO BE REMOVED, SHALL BE CLEANED AND SAVED, REUSED, RETURNED TO BUILDING STOCK, OR DISPOSED OF AS DIRECTED BY U.S. BANK PROJECT MANAGER AND/OR PROPERTY MANAGER. E. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH APPROPRIATE SERVICE COMPANY PRIOR TO PROCEEDING WITH REMOVAL. F. GENERAL CONTRACTOR TO COVER ALL SMOKE DETECTORS, FIRE HORNS/STROBES, RETURN AIR GRILLS, DRINKING FOUNTAINS, ETC. TO PREVENT DAMAGE FROM DUST AND APPLICATION OF NEW FINISHES. PROVIDE TEMPORARY EXHAUST DURING CONSTRUCTION OPERATIONS. TO THE GREATEST EXTENT POSSIBLE, ISOLATE AND/OR SHUT DOWN THE RETURN SIDE OF THE HVAC SYSTEM DURING CONSTRUCTION. WHEN VENTILATION SYSTEM MUST BE OPERATIONAL DURING CONSTRUCTION ACTIVITIES, PROVIDE TEMPORARY FILTERS. G. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN QUESTION WITH THE U.S. BANK PROJECT MANAGER AND PROPERTY MANAGER BEFORE PROCEEDING. H. ALL EGRESS PATHS SHALL REMAIN FREE AND CLEAR OF ALL OBSTRUCTIONS AT ALL TIMES DURING THE FULL DURATION OF CONSTRUCTION. NO STORAGE IS PERMITTED IN ANY EGRESS PATH. I. IF THE CONTRACTOR ENCOUNTERS MATERIAL THAT IT REASONABLY BELIEVES TO BE HAZARDOUS (ASBESTOS, MOLD, ETC), THE CONTRACTOR SHALL IMMEDIATELY SUSPEND WORK IN THE AREA AND REPORT THE CONDITION TO THE OWNER AND THE U.S. BANK PROJECT MANAGER. J. DO NOT REMOVE ANY EXISTING STRUCTURAL MATERIALS OR, WHERE APPLICABLE, EXISTING FIRE PROOFING WITHOUT CONSULTING THE ARCHITECT, JLL OWNER'S REPRESENTATIVE, AND THE LANDLORD. IF ANY EXISTING FIRE PROOFING IS DAMAGED IN ANY WAY, CONTACT ARCHITECT, JLL OWNER'S REPRESENTATIVE, AND LANDLORD IMMEDIATELY. K. REMOVE AND DISPOSE OF EXISTING MARKETING PIECES. COORDINATE WITH U.S. BANK PROJECT MANAGER. PATCH AND REPAIR WALLS AND/OR REPLACE CEILING TILES AS REQUIRED FOR LIKE-NEW FINISH. L. EXISTING ACOUSTICAL CEILING GRID, TILE, GYPSUM BOARD SOFFITS AND FASCIAS, AND LIGHTING FIXTURES TO REMAIN THROUGHOUT AREA OF WORK, UNLESS NOTED OTHERWISE. M. REMOVE EXISTING FLOOR FINISH AND WALL BASE THROUGHOUT AREA OF WORK, UNLESS NOTED OTHERWISE. REMOVE ALL GLUE AND IMPERFECTIONS. PREP AS REQUIRED TO RECEIVE NEW FLOOR FINISHES. REFER TO FINISHES PLAN FOR ADDITIONAL INFORMATION. N. REMOVE EXISTING WALL FINISH AND WALLCOVERING THROUGHTOUGH AREA OF WORK, UNLESS NOTED OTHERWISE. PROVIDE LEVEL 4 FINISH AT LOCATIONS OF WALL COVERING REMOVAL. REFER TO FINISHES PLAN FOR ADDITIONAL INFORMATION. O. EXISTING POWER/VOICE/DATA DEVICES TO REMAIN THROUGHOUT AREA OF WORK, UNLESS NOTED OTHERWISE. REFER TO PVD PLAN FOR ADDITIONAL INFORMATION. P. ALL EXISTING BACK OF HOUSE EQUIPMENT TO REMAIN, UNLESS NOTED OTHERWISE. COORDINATE WITH FACILITY MANAGER AND U.S. BANK MANAGER. Q. REMOVE ALL EXISTING FURNITURE AND FURNITURE SYSTEMS AS INDICATED ON PLANS. REUSE AND RELOCATION TO BE COORDINATED WITH U.S. BANK PROJECT MANAGER. R. EXISTING WINDOW TREATMENTS THOUGHOUT AREA OF WORK TO REMAIN, UNLESS NOTED OTHERWISE. PROTECT DURING DEMOLITION AND CONSTRUCTION. S. U.S. BANK SECURITY VENDOR TO COORDINATE SECURITY EQUIPMENT WITH PROJECT SCOPE. PATCH AND REPAIR CEILING GRID AND WALLS AS REQUIRED FOR LIKE NEW FINISH. NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 P D P D P D D20A 2 2 2 2 2 2 2 228"28"242"42" F1 F1 F1 2 A901 3 A901 4 SD VAULT 111 CASH SAFE 112 MECH/NER 113 SD VAULT CIRCULATION 107 COUPON ROOM 110 COUPON ROOM 109 ATM / NIGHT DROP 106 CONFERENCE 120 WOMEN'S RESTROOM 117 MEN'S RESTROOM 118 BREAKROOM 114 CIRCULATION 116 TELLER LINE 108 ATM 103 ENTRY 101 WAITING 104 LOBBY 102 ENTRY 105 PLATFORMS 121 PLATFORMS 119 STORAGE 115 A1 A1 A1 A2 A3 A4 A1 107 102 108 E1 E1 E1 E2 1' - 4 " A5 E3E3 E3 E3 8' - 1 1 " 8 ' - 1 0 " A6 A6 A6 E4 E3 E4 10 ' - 6 " E3 E4 E5 A6 A6 E6 101 105 30x48 3' - 0" 5' - 0 " 2' - 0" 4' - 0 " 1' - 10" PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:04 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 GROUND FLOOR ARCHITECTURAL AND PVD PLAN A101 101 E Foothill Blvd, Arcadia, CA 91006 GENERAL NOTES -FLOOR PLAN (CA) A. LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS SHALL BE IN ACCORDANCE WITH CFC 906 AND CALIFORNIA CODE OF REGULATIONS (CCR), TITLE 19. B. DURING CONSTRUCTION, AT LEAST ONE EXTINGUISHER SHALL BE PROVIDED ON EACH FLOOR LEVEL AT EACH STAIRWAY, IN ALL STORAGE AND CONSTRUCTION SHEDS, IN LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE STORED OR USED, AND WHERE OTHER SPECIAL HAZARDS ARE PRESENT PER CFC SECTION 3315.1. C. BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION, OR DEMOLITION SHALL CONFORM TO CFC CHAPTER 33. WELDING, CUTTING, AND OTHER WORK SHALL BE IN CONFORMANCE WITH CFC CHAPTER 35. D. EXITS, EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS, FIRE EXTINGUISHER LOCATIONS, AND STANDPIPE CONNECTIONS SHALL NOT BE CONCEALED BY CURTAINS, MIRRORS, OR OTHER DECORATIVE MATERIAL. E. THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF ALL OBSTRUCTIONS AT ALL TIMES. NO STORAGE IS PERMITTED IN ANY EGRESS PATHS. F. ADHESIVES, SEALANTS, CAULKS. ADHESIVES AND SEALANTS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS. (SECTION 5.504.4.1 OF CAL GREEN) ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS, AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4.1 AND 5.504.4.2 OF CALGREEN. (SEC. 5.504.4.1). A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT MATERIAL HAS BEEN USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. G. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507 H. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE 5.504.4.2 UNLESS MORE STRINGENT LOCAL LIMITS APPLY (SECTION 5.504.3 OF CALGREEN). COORDINATE WITH CALGREEN INFORMATION IN THE PROJECT SPECIFICATIONS. A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT PAINT HAS BEEN USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. I. AEROSOL PAINTS AND COATINGS. AEROSOL PAINTS AND COATINGS SHALL MEET THE PRODUCT-WEIGHTED MIR LIMITS FOR ROC IN SECTION 94522(A)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES (CCR, TITLE 17, SECTION 94520 ET SEQ). (SECTION 5.504.4.3.1 OF CALGREEN) LEGEND -FLOOR PLAN EXISTING PARTITION TO REMAIN NOT IN SCOPE EXISTING DOOR AND FRAME TO REMAIN KEYNOTES - FLOOR PLAN NO. DESCRIPTION A1 MODIFY EXISTING TELLER LINE TO PROVIDE NEW COUNTERTOP SUPPORTS AS REQUIRED FOR NEW SOLID SURFACE COUNTERTOP. A2 PROVIDE NEW PLAM PANELS UNDER EXISTING COUNTERTOP AS REQUIRED TO ENCLOSE TCR UNIT. PLAM FINISH TO MATCH EXSITING ADJACENT. SEE ELEVATIONS ON A901 FOR ADDITIONAL INFORMATION. A3 PROVIDE REMOVABLE ACCESS PANEL AT SIDE OF NEW PLAM PANEL. SEE MILLWORK VENDOR DRAWINGS FOR ADDITIONAL INFORMATION. A4 NEW TELLER CASH RECYCLING EQUIPMENT TO BE PROVIDED BY OWNER. COORDINATE POWER AND DATA REQUIREMENTS WITH TCR VENDOR. A5 AT NEW SOLID SURFACE COUNTERTOP PROVIDE 6" CONTINUOUS OVERHANG AT CUSTOMER FACING SIDE OF TELLER LINE. ALL OTHER LOCATIONS TO MATCH EXISTING DEMOLISHED DEPTH. A6 NO NEW WORK- SEE OTHER PLANS FOR SCOPE OF WORK AT THIS AREA. GENERAL NOTES -FLOOR PLAN A. ALL DIMENSIONS SHOWN ARE TO FINISHED FACE OF WALL. (U.N.O.). ALIGN WALLS WITH ADJACENT SURFACES IF IT APPEARS TO ALIGN. LOCATIONS THAT ARE UNCLEAR WILL BE KEYNOTED. B. ALL CLEAR DIMENSIONS ARE TO BE EXACT WITHIN 1/8"; ALONG FULL HEIGHT AND FULL WIDTH OF WALLS. CONTRACTOR SHALL NOT ADJUST ANY DIMENSIONS MARKED "CLEAR" OR "CLR" WITHOUT WRITTEN INSTRUCTION FROM THE ARCHITECT. C. WHERE PRESENT, VERIFY INTEGRITY OF EXISTING FIRE-RATED PARTITIONS TO REMAIN AND REPORT FINDINGS TO THE PROJECT MANAGER. D. WHERE PRESENT, GENERAL CONTRACTOR RESPONSIBLE FOR MAINTAINING INTEGRITY OF EXISTING FIRE-PROOFING.IF ANY EXISTING FIRE PROOFING IS DAMAGED IN ANY WAY, CONTACT ARCHITECT, JLL OWNER'S REPRESENTATIVE, AND LANDLORD IMMEDIATELY. E. IF THE CONTRACTOR ENCOUNTERS MATERIAL THAT THEY REASONABLY BELIEVE TO BE HAZARDOUS (ASBESTOS, MOLD, ETC), THE CONTRACTOR SHALL IMMEDIATELY SUSPEND WORK IN THE AREA AND REPORT THE CONDITION TO THE OWNER AND THE ARCHITECT. F. PROVIDE FIRE-RETARDANT PLYWOOD BLOCKING FOR ALL WALL MOUNTED FIXTURES, EQUIPMENT, AND SIGNAGE. 1/4" = 1'-0"1 GROUND FLOOR ARCHITECTURAL, POWER, VOICE AND COMMUNICATIONS PLAN PLAN NORTH N GENERAL NOTES -POWER & COMM. A. THIS SHEET IS FOR DESIGN INTENT AND LOCATIONS OF POWER, VOICE, DATA AND CARD READER DEVICES ONLY. B. FIRE SAFETY MUST BE MAINTAINED FOR ALL PERSONNEL WORKING ON THE FLOOR. ALL FIRE ALARMS, SPEAKERS, ETC. MUST REMAIN OPERABLE AT ALL TIMES. NOTIFY BUILDING SECURITY AND BUILDING MANAGER OF DAMAGED SYSTEMS AND REPAIR OR REPLACE DAMAGED SYSTEMS IMMEDIATELY. C. ELECTRICAL AND/OR DATA LINES THAT ARE NOT WITHIN U.S. BANK OWNED OR LEASED SPACE SHALL BE IN CONDUIT. D. ELECTRICAL CONTRACTOR SHALL PROPERLY LABEL ALL ELECTRICAL PANELS. E. LIGHT SWITCHES, OUTLETS AND RECEPTACLE COVER PLATES TO BE WHITE IN COLOR, U.N.O. ALL EXISTING LIGHT SWITCHES, OUTLETS AND COVER PLATES TO BE REPLACED WITH WHITE, U.N.O. F. ALL POWER, VOICE & DATA DIMENSIONS ARE TO THE CENTERLINE OF OUTLETS / DEVICES OR TO THE CENTERLINE OF OUTLET / DEVICE CLUSTER GROUPS, U.N.O. G. INSTALL ADJACENTLY LOCATED ELECTRICAL / DATA OUTLETS AND/OR DEVICES AS CLOSE TOGETHER AS POSSIBLE ON PARTITIONS. H. OUTLETS SHOWN BACK TO BACK ON PARTITION WALLS SHALL BE OFFSET 1'-0", MINIMUM OR MOUNTED AT DIFFERENT HEIGHTS IF INDICATED. I. INSTALL WALL MOUNTED OUTLETS 18 INCHES ABOVE FINISHED FLOOR, U.N.O. J. COORDINATE DEVICE LOCATIONS WITH GRAPHICS PACKAGE. K. ALL POWER VOICE & DATA DEVICES WITHIN AREA OF WORK SCOPE IS TO REMAIN, U.N.O L. USE EXISTING ELECTRICAL AND VOICE/DATA OUTLETS ON WALL WHEN POSSIBLE. KEYNOTES - POWER & COMM. NO. DESCRIPTION E1 GC TO COORDINATE FINAL FLOOR CORE LOCATION WITH FURNITURE VENDOR AND U.S. BANK PROJECT MANAGER, NOTIFY ARCHITECT AND U.S. BANK PROJECT MANAGER OF ANY OBSTRUCTIONS WHICH MAY AFFECT THE LOCATION OF THE CORES NOTED ON PLANS. E2 LOCATION OF FUTURE ATM. E3 CALIFORNIA TITLE 24 REQUIREMENTS FOR ENERGY: HALF OF THE DUPLEX OUTLETS WITHIN EACH WORKSTATION TO BE ON A CONTROLLED SHUT OFF. FURNITURE SYSTEM IS STEELCASE ANSWER. ELECTRICAL CIRCUITS ARE A 3+1 CONFIGURATION. CIRCUIT 2 TO BE CONTROLLED WITH AN AUTOMATIC TIMER PROVIDED BY THE ELECTRICIAN AT THE CIRCUIT LEVEL. DUPLEX RECEPTACLE 2 TO BE PERMANENTLY LABELED WITH THE WORD "CONTROLLED" AND PROVIDED BY THE STEELCASE FURNITURE DEALER. E4 PROVIDE ONE JUNCTION BOX FOR DATA AND ONE JUNCTION BOX FOR POWER WITH 4-WIRE CIRCUIT USING 1, 2, AND 3 OF THE 3+1 WIRING SYSTEM INTO THE FURNITURE PANEL. E5 MODIFY EXISTING CONNECTRAC CONNCECTION AS REQUIRED FOR INWALL ENTERANCE FITTTING LOCATED AS CLOSE TO FLOOR AS POSSIBLE. E6 MODIFY JUNCTION BOX AS REQUIRED FOR INWALL ENTRANCE FITTING TO ALIGN WITH EXISTING LOCATION P D 42" DUPLEX OUTLET DEVICE HEIGHT A.F.F. QUAD OUTLET DATA OUTLET (1) DATA PORT PROVIDED QUANTITY OF DATA PORTS JUNCTION BOX -VOICE/DATA FEED TO FURNITURE JUNCTION BOX -POWER FEED TO FURNITURE 5 LEGEND - POWER & COMM. NOTE: HALFTONE SYMBOLS IS EXISTING TO REMAIN JUNCTION BOXJ (SQUARE) 4" LEGRAND RFB2-OG FLOOR BOX (SLAB ON GRADE) FURNITURE FEED DEVICE: FPFFTCAL COVER PLATE (1) 3/4" CONDUIT FOR POWER (1) 1-1/4" CONDUIT FOR DATA F1 HARDWARE SUMMARY -REFER TO SPECIFICATIONS FOR COMPLETE HARDWARE GROUP INFORMATION GENERAL NOTES -HARDWARE A. GC TO COORDINATE WITH JLL PM AND U.S. BANK FACILITY MANAGER TO CONFIRM REQUIRED CYLINDER IS LARGE OR STANDARD. B. REFER TO SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE GROUPS. C. WHERE EXISTING DOORS ARE SCHEDULED, G.C. TO FIELD VERIFY OPENING SIZES, DOOR TYPE AND THICKNESSES. DOOR SCHEDULE DOOR FRAME SPECS. COMMENTSNO. ROOM NAME W H T TYPE MATL. GLASS TYPE MATL. GLASS RATING HDWR. 101 ENTRY 6' - 0" 7' - 0" 1 3/4" EXIST HM EXIST EXIST EXIST EXIST -- 11.0 1,2,3 102 SD VAULT CIRCULATION 3' - 0" 2' - 10" 1 1/2" FG LAM-2 EXIST EXIST LAM-2 EXIST -- 1.0 1,2 105 ENTRY 6' - 0" 7' - 0" 1 3/4" EXIST HM EXIST EXIST EXIST EXIST -- 11.0 1,2,3 107 TELLER LINE 3' - 0" 3' - 6" 1 1/2" FG LAM-2 EXIST EXIST LAM-2 EXIST -- 6.1 1,2 108 TELLER LINE 3' - 0" 7' - 0" 1 1/2" FG LAM-2 EXIST EXIST LAM-2 EXIST -- 6.1 1,2 NO. DATE DESCRIPTION 1 09/19/2025 PLAN REVIEW COMMENTS DOOR SCHEDULE COMMENTS: 1. LAMINATE FINISH TO BE INSTALLED ON DOOR WHERE PREVIOUS LAMINATE WAS REMOVED. 2. AT OPENINGS WHERE A NEW HARDWARE GROUP IS NOTED AT AN EXISTING DOOR AND DOOR FRAME: HARDWARE SUPPLIER TO SURVEY EXISTING CONDITIONS TO DETERMINE HARDWARE FINISH AND CONDITION OF EXISTING HARDWARE. REPLACE ALL HARDWARE WHICH DOES NOT MATCH SPECIFIED FINISH COLOR. REPLACE DAMAGED OR NON-OPERATING HARDWARE WHICH MATCH SPECIFIED FINISH COLOR, AND REPLACE WITH ITEMS SPECIFIED IN NOTED GROUP, AS WELL AS INSTALLING SPECIFIED ITEMS THAT ARE CURRENTLY NOT PRESENT. 3. FINISH OF HARDWARE TO MATCH EXISTING STOREFRONT. 1 1 W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 LAM-6 LAM-6 LAM-6 LAM-5 LAM-5 SCRIBED TO FLOOR, TYP. SCRIBED TO FLOOR, TYP. LAM-2 LAM-2 LAM-2 SS-2 SS-2 V.I . F . 2' - 1 0 " M A X AT NEW COUNTERTOP, PROVIDE 6" CONTINUOUS OVERHANG AT CUSTOMER FACING SIDE OF TELLER LINE. ALL OTHER LOCATIONS TO MATCH EXISTING DEMOLISHED DEPTH. LAM-2 V.I.F. 37' - 5" B.O. EXISTING SOFFIT B.O. EXISTING CEILING U.S. BANK SIGNAGE VENDOR TO PROVIDE FULL HEIGHT OPAQUE FILM AT EXISTING BR GLASS. LAM-2 GR A I N GR A I N GR A I N GR A I N 1 1 / 2 " VIF 3' - 1 1/2" VIF 3' - 7 1/16" FUTURE TCR SS-2 SS-2 LAM-2 LAM-6 LAM-2 ALL EXPOSED SURFACES ALL EXPOSED SURFACES LAM-2 V. I . F . 2' - 1 0 " 0" ALL EXPOSED SURFACES, TYP. LAM-2 V. I . F . 3' - 4 " 1 1 / 2 " LAM-6 ALL EXPOSED SURFACES LAM-6 ALL EXPOSED SURFACES NOTE: EXISTING EQUIPMENT & UNDERCOUNTER STEEL TO REMAIN, TYP. U.S. BANK SIGNAGE VENDOR TO PROVIDE FULL HEIGHT OPAQUE FILM AT EXISTING BR GLASS. LAM-2 ALL EXPOSED SURFACES LAM-2 GR A I N LAM-2 ALL EXPOSED SURFACES SS-2 NEW MILLWORK PANELS AT TCR LOCATION V.I.F. EXISTING ALL EXPOSED SURFACES ALL EXPOSED SURFACES AT NEW COUNTERTOP, PROVIDE 6" CONTINUOUS OVERHANG AT CUSTOMER FACING SIDE OF TELLER LINE. ALL OTHER LOCATIONS TO MATCH EXISTING DEMOLISHED DEPTH. GR A I N GR A I N GR A I N GR A I N GR A I N GR A I N GR A I N GR A I N GR A I N GR A I N GR A I N LAM-2 ALL UNDERCOUNTER EXPOSED SURFACES TYP. LAM-2 ALL UNDERCOUNTER EXPOSED SURFACES TYP. LAM-2 ALL UNDERCOUNTER EXPOSED SURFACES TYP. 1 1 / 2 " 3 mm PVC EDGE PER SECTION 1" FACE OF CABINET PLAM ON 3/4" CORE MATERIAL. SHIP BACKSPLASHES AND SIDESPLASHES LOOSE. SET IN CONTINUOUS BED OF SEALANT. 1/8" EASED EDGE- TYP. FACE OF CABINET 1/2" SOLID SURFACE MATERIAL ON 3/4" CORE MATERIAL. SET IN CONTINUOUS BED OF SEALANT. SCRIBE TO WALL 1 1 / 2 " PER SECTION 1" PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:06 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 INTERIOR ELEVATIONS A901 101 E Foothill Blvd, Arcadia, CA 91006 1" = 1'-0"1 LAMINATE COUNTERTOP SECTION 1" = 1'-0"2 SOLID SURFACE COUNTERTOP SECTION 1/2" = 1'-0"3 ELEVATION AT TELLER LINE 1/2" = 1'-0"4 ELEVATION BEHIND TELLER LINE B.O. EXISTING CEILING NO. DATE DESCRIPTION 1 09/19/2025 PLAN REVIEW COMMENTS 1 1 W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 CARPET RESILIENT FLOOR TRS-5 SEE FINISH SCHEDULE CONCRETE FLOOR TILE CARPET TRS-2 SEE FINISH SCHEDULE CONCRETE FLOOR SHAW CONTRACT FLOORING TYPE PROVIDED BY INSTALLED BY NOTES CPT NOTES: 1. GC TO COORDINATE INSTALL AND SCHEDULE WITH SHAW INTERGRATED SOLUTIONS. 2. NOT INCLUDED ON THIS PROJECT. SHAW LVT SHAW SHAW SHAW ESD VB SHAW SHAW SHAW SHAW 1 1 2 1 CONCRETE FLOOR DOOR - SEE DOOR SCHEDULE RESILIENT FLOORTILE * PROVIDE FLOOR LEVELING COMPOUND UNDER VINYL TO MEET TRANSITION TRS-2 EQ EQ TLCPT GR A I N SD VAULT 111 CASH SAFE 112 MECH/NER 113 SD VAULT CIRCULATION 107 COUPON ROOM 110 COUPON ROOM 109 ATM / NIGHT DROP 106 CONFERENCE 120 WOMEN'S RESTROOM 117 MEN'S RESTROOM 118 BREAKROOM 114 CIRCULATION 116 TELLER LINE 108 ENTRY 101 LOBBY 102 ENTRY 105 PLATFORMS 121 PLATFORMS 119 STORAGE 115 TL EX . CP T TL CP T TL LV T CP T LV T CP T EX . LV T EX . CP T TL CP T TL CP T CPTTL EX.LVT CPT-3 CPT-3 CPT-9 CPT-9 CPT-9 CPT-11 CPT-11 CPT-11 CPT-11 CPT-11 CPT-11 TL-8 LVT-2 GRAIN GRAIN GRAIN GRAIN GRAIN GRAINGRAIN GRAIN GRAIN GRAIN GRAIN GRAIN F1 PT-1B F2 F2 F2 12 ' - 0 " PT-18B PT-18B PT-18B PT-13B F3 F4 F5 F6 F6 F7 F10 F10 F8 F8 F9 F9 F10 LVT-2 LVT-2 PT-18B F10 CARPET SEALED CONCRETE TRS-13 SEE FINISH SCHEDULE CONCRETE FLOOR 3" = 1'-0"4 CARPET TO RESILIENT FLOOR TRANSITION PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:08 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 GROUND FLOOR FINISH PLAN i101 101 E Foothill Blvd, Arcadia, CA 91006 GENERAL NOTES -FINISH PLAN A. THE AVAILABILITY OF ALL MATERIALS DESIGNATED ON THE PLANS SHALL BE VERIFIED BY CONTRACTORS AND SUBCONTRACTORS PRIOR TO ESTIMATE SUBMITTALS. CONTRACTOR TO NOTIFY PROJECT MANAGER IF SPECIFIED MATERIALS ARE NOT AVAILABLE. ANY SUBSTITUTIONS TO BE REVIEWED AND APPROVED BY THE PROJECT MANAGER AND ARCHITECT. B. CONTRACTORS SHALL FOLLOW MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF ALL MATERIALS. C. REFER TO SHEET i102 FOR FINISH SCHEDULE. D. PROVIDE TRANSITION STRIPS AT LOCATIONS WHERE TWO DISSIMILAR FLOOR FINISH MATERIALS MEET. SEE DETAILS ON i101 AND FINISH SCHEDULE ON SHEET i102 FOR MORE INFORMATION. E. LOCATE CHANGE IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR U.N.O. F. GYP CEILINGS AND SOFFITS TO RECEIVE [PT-1A] U.N.O. G. WHERE WALL FINISH CHANGES OCCUR, TERMINATE FINISH AT INSIDE CORNERS UNO. H. HOLLOW METAL DOORS AND HOLLOW METAL FRAMES ARE TO RECEIVE PAINT TO MATCH ADJACENT WALL SURFACE WITH A SEMI- GLOSS FINISH. I. WALLS TO RECEIVE [PT-1B] AND [VB-3], U.N.O. J. REFER TO ARCHITECTURAL SHEETS AND ELEVATIONS FOR ADDITIONAL INFORMATION ON FINISHES AND LOCATIONS. K. CONTRACTOR TO ENSURE ALL SUBSTRATES ARE FLUSH AND SMOOTH FOR FINAL WALL, CEILING AND FLOOR FINISH MATERIAL INSTALLATION. L. PROVIDE LEVEL 5 FINISH PAINTED [PT-1C] AT GRAPHIC WALL. COORDINATE ALL GRAPHIC LOCATIONS WITH U.S. BANK SIGNAGE VENDOR. M. FLOORING AND FURNITURE VENDORS TO ALIGN ON FLOORING AND FURNITURE INSTALL LOCATIONS PRIOR TO INSTALLATION. ANCHOR DIMENSION TO BE THE SAME FOR FURNITURE AND FLOORING. REACH OUT TO ARCHITECT IF DISCREPANCIES EXIST IN FIELD. N. AT MAIN TRANSITION AREAS, PROVIDE A FULL CARPET TILE. ALL CUT CARPET TILE TO FALL AT EXTERIOR WALLS IF POSSIBLE. O. ALTERED OR CUT CARPET TILES NOT TO BE SMALLER THAN 6". GENERAL NOTES -FINISH PLAN (CA) A. FLOOR FINISHES AND MATERIALS SHALL NOT EXCEED THE INTERIOR FINISH CLASSIFICATIONS IN CBC TABLE 803.9 AND SHALL MEET THE FLAME PROPAGATION PERFORMANCE CRITERIA OF THE CALIFORNIA CODE OF REGULATIONS, TITLE 19, DIVISION 1. DECORATIVE MATERIALS SHALL BE PROPERLY TREATED BY A PRODUCT OR PROCESS APPROVED BY THE STATE FIRE MARSHAL WITH APPROPRIATE DOCUMENTATION PROVIDED TO THE CITY. B. ADHESIVES, SEALANTS, CAULKS. ADHESIVES AND SEALANTS USED ON THE PROJECT SHALL MEET THE REQUIREMENTS OF THE FOLLOWING STANDARDS. (SECTION 5.504.4.1 OF CALGREEN) ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, SEALANT PRIMERS, AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE APPLICABLE, OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLES 5.504.4.1 AND 5.504.4.2 OF CALGREEN. (SEC. 5.504.4.1). A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT MATERIAL HAS BEEN USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. C. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94507. D. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE 5.504.4.2 UNLESS MORE STRINGENT LOCAL LIMITS APPLY (SECTION 5.504.3 OF CALGREEN). COORDINATE WITH CALGREEN INFORMATION IN THE PROJECT SPECIFICATIONS. A LETTER FROM THE CONTRACTOR AND OR THE BUILDING OWNER CERTIFYING WHAT PAINT HAS BEEN USED AND ITS COMPLIANCE WITH THE CODE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. E. AEROSOL PAINTS AND COATINGS. AEROSOL PAINTS AND COATINGS SHALL MEET THE PRODUCT-WEIGHTED MIR LIMITS FOR ROC IN SECTION 94522(A)(3) AND OTHER REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING SUBSTANCES (CCR, TITLE 17, SECTION 94520 ET SEQ). (SECTION 5.504.4.3.1 OF CALGREEN). F. ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PROGRAM. ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 804.4.1. A LETTER FROM THE INSTALLER CERTIFYING COMPLIANCE MUST BE SUBMITTED TO THE BUILDING INSPECTOR. G. ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET AT LEAST ONE OF THE FOLLOWING TESTING AND PRODUCT REQUIREMENTS WHICH ARE LISTED IN SECTION 5.504.4.4 OF CALGREEN. 1. CARPET AND RUG INSTITUTES' GREEN LABEL PLUS PROGRAM. 2. COMPLIANT WITH THE VOC-EMISSION LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH STANDARD METHOD FOR TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS, VERSION 1.1, FEBRUARY 2010 (ALSO KNOWN AS CDPH STANDARD METHOD V1.1 OR SPECIFICATION 01350) 3. NSF/ANSI 140 AT THE GOLD LEVEL OR HIGHER. 4. SCIENTIFIC CERTIFICATION SYSTEMS SUSTAINABLE CHOICE 5. COMPLIANCE WITH THE CALIFORNIA COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CA-CHPS) CRITERIA INTERPRETATION FOR EQ 2.2 DATED JULY 2012 AND LISTED IN THE CHPS HIGH PERFORMANCE PRODUCT DATABASE. H. AT LEAST 80% OF THE FLOOR AREA RECEIVING RESILIENT FLOORING SHALL MEET ONE OF THE FOLLOWING CRITERIA: 1. CERTIFIED UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM. 2. COMPLIANT WITH THE VOC-EMISSION LIMITS AND TESTING REQUIREMENTS SPECIFIED IN THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH'S 2010 STANDARD METHOD FOR THE TESTING AND EVALUATION CHAMBERS, VERSION 1.1, FEBRUARY 2010. 3. COMPLIANT WITH THE CALIFORNIA COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CA-CHPS) CRITERIA INTERPRETATION FOR EQ 2.2 DATED JULY 2012 AND LISTED IN THE CHPS HIGH PERFORMANCE PRODUCT DATABASE. 4. COMPLIANT WITH CDPH CRITERIA AS CERTIFIED UNDER THE GREENGUARD CHILDREN'S & SCHOOL PROGRAM. KEYNOTES - FINISH PLAN NO. DESCRIPTION F1 EXISTING FLOOR AND WALL BASE TO REMAIN, ONLY SCOPE WITHIN WALL IS [PT-1B] AT INDICATED FULL HEIGHT WALLS. F2 ALIGN FLOORING TRANSITION WITH EXISTING WALL F3 EXISTING SOFFIT TO BE PAINTED [PT-13B] AND [PT-13A], AS REQUIRED. F4 FLOORING TRANSITION TO ALIGN TO CENTERLINE OF EXISTING MULLION. F5 NEW CARPET TO BE INSTALLED OVER EXISTING CONNECT TRAC F6 PAINT TOP OF PARTIAL HEIGHT WALL [PT-1B]. F7 U.S. BANK SIGNAGE VENDOR TO PROVIDE FULL HEIGHT OPAQUE FILM AT EXISTING BR GLASS. F8 DO NOT PAINT EXISTING LAMINATE SURFACED WALLS. WALLS ARE TO BE RELAMINATED, REFER TO ELEVATIONS ON SHEET A901 FOR MORE INFORMATION. F9 PROVIDE [LAM-2] AT WALLS AND ADJACENT DOORS. APPLICATION LOCATIONS TO MATCH EXISTING LOCATIONS. F10 PROVIDE [LAM-1] AT WALLS AND/OR ADJACENT DOORS. APPLICATION LOCATIONS TO MATCH EXISTING LOCATIONS. 3" = 1'-0"3 CARPET TO TILE TRANSITION 3" = 1'-0"6 TILE TO RESILIENT FLOOR TRANSITION N 1/4" = 1'-0"1 GROUND FLOOR FINISH PLAN 3" = 1'-0"5 CARPET TO SEALED CONCRETE TRANSITION NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:09 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 FINISH & FURNITURE SCHEDULES i102 101 E Foothill Blvd, Arcadia, CA 91006 INTERIOR MATERIALS SCHEDULE1 MATERIAL ID SPEC. SECTION DESCRIPTION MANUFACTURER STYLE COLOR FINISH SIZE INSTALLATION METHOD CONTACT LOCATION CPT-3 09 68 10 CARPET TILE SHAW CONTRACT WELCOME II TILE 5T031 STERLING 31557 24" X 24" STACK NADINE HEITHAUS, 513-479-8557 WALKOFF CARPET AT MAIN ENTRIES CPT-9 09 68 10 CARPET TILE SHAW CONTRACT COLOR FORM 5T112 FIGMENT 81486 9" x 36" ASHLAR NADINE HEITHAUS, 513-479-8557 BLUE ACCENT CARPET AT CONFERENCE ROOM AND PLATFORMS CPT-11 09 68 10 CARPET TILE SHAW CONTRACT CITY CENTRAL TILE 5T175 VILLAGE 72760 9" X 36" ASHLAR NADINE HEITHAUS, 513-479-8557 GENERAL FIELD CARPET GR-3 09 30 00 TILE LATICRETE GROUT 60 DUSTY GREY PERMACOLOR SELECT SEE LOCATION ON TILE SPEC FOR SPECIFIC APPLICATION. USE WITH [TL-8] LAM-1 06 40 23 PLASTIC LAMINATE WILSONART DESIGNER WHITE D354-60 MATTE LYNETTE STENDE, 612-500-6020 LAMINATE AT PARTIAL HEIGHT WALLS LAM-2 06 40 23 PLASTIC LAMINATE WILSONART LANDMARK WOOD 7981K-12 SOFT GRAIN LYNETTE STENDE, 612-500-6020 FIELD MILLWORK FINISH AT TELLER LINE AND ADJACENT PARTIAL HEIGHT WALLS, SEE ARCHITECTURAL PLANS AND ELEVATIONS FOR MORE INFORMATION LAM-5 06 40 23 PLASTIC LAMINATE WILSONART #6277 (419) ALUMASTEEL DECORATIVE METALS 4" HIGH 4" FOOT KICK AT BASE OF TELLER LINE LAM-6 06 40 23 PLASTIC LAMINATE FORMICA #969-58 NAVY BLUE MATTE FINISH BLUE ACCENT LAMINATE AT TELLER LINE LVT-2 09 65 19 LUXURY VINYL TILE SHAW CONTRACT STRAND 0516V WOOL 16115 18" X 36" ASHLAR NADINE HEITHAUS, 513-479-8557 BREAKROOM FLOOR PT-1A 09 91 00 PAINT SHERWIN WILLIAMS SW7006 EXTRA WHITE FLAT ENAMEL PAINT AT CEILINGS PT-1B 09 91 00 PAINT SHERWIN WILLIAMS SW7006 EXTRA WHITE EGGSHELL GENERAL WALL PAINT, SOFFIT, BULKHEADS PT-1C 09 91 00 PAINT SHERWIN WILLIAMS SW7006 EXTRA WHITE SEMI-GLOSS DOORS, FRAMES, TRIM AND MISC METALS TO BE PAINTED TO MATCH WALL BEYOND PT-13A 09 91 00 PAINT BENJAMIN MOORE 2065-10 ADMIRAL BLUE FLAT ENAMEL BLUE ACCENT CEILING AND SOFFIT PT-13B 09 91 00 PAINT BENJAMIN MOORE 2065-10 ADMIRAL BLUE EGGSHELL BLUE ACCENT WALL PT-18B 09 91 00 PAINT SHERWIN WILLIAMS MARCH WIND SW7668 EGGSHELL GREY ACCENT WALL PT-18C 09 91 00 PAINT SHERWIN WILLIAMS MARCH WIND SW7668 SEMI-GLOSS GREY ACCENT PAINT AT MISC METALS TO MATCH ADJACENT WALL FINISH SS-2 06 61 40 SOLID SURFACE CORIAN STONIQUE N/A NEW COUNTERTOP AT TELLER LINE TL-8 09 30 00 TILE TILE x DESIGN LEGNO D'METRO ARCO MATTE 12" X 24" 1/3RD OFFSET. SEE GRAIN DIRECTION ON FINISH PLAN. JENNIFER CHRISTOPHER, 763-268-0318 FIELD TILE. USE GR-3. TRS-2 09 30 00 TILE TRIM/TRANSITION STRIP SCHLUTER SYSTEMS SCHIENE ANODIZED ALUMINUM AE ANODIZED ALUMINUM AE TRANSITION STRIP AT CARPET TO FLOOR TILE TRANSITIONS TRS-5 09 65 19 TRANSITION STRIP SHAW CONTRACT TRANSITION STRIP NIGHT 00066 NADINE HEITHAUS, 513-479-8557 LVT TO CPT TRANSITION MATERIAL TRS-13 09 65 19 REDUCER SHAW CONTRACT TRANSITION STRIP NIGHT 00066 NADINE HEITHAUS, 513-479-8557 CARPET TO CONCRETE VB-3 09651 VINYL BASE - 09651 SHAW CONTRACT SCULPTURED BASE - 150VS NIGHT 00066 4.5" X 96" ADHESIVE: WALL BASE ADHESIVE, 141VS | TUBE, 166VS | 1 GALLON, 136VS |4 GALLON NADINE HEITHAUS, 513-479-8557 FIELD WALL BASE FURNITURE SCHEDULE Furnitur e ID Manufacturer Product Name Product Number Furniture Dimension Surface Leg/Base/Frame Upholstery: Seat Upholstery: Back Other Finishes Comments Type Comments C3C COALESSE MONTARA650 COSFZCH 20.2"W x 18.5" D x 36.2" H SLED BASE, POLISHED CHROME DESIGNTEX | GAMUT - CHERRY 3468-304 WOODSHELL| WHITE OAK VP05 C5A COALESSE BINDU CO300G 25”D 24 1/2”W 37 3/4”H POLISHED CHROME STEELCASE | BRISA; BR10 NIGHT NAVY STEELCASE | BRISA; BR10 NIGHT NAVY C6A STEELCASE NOOI CAFETERIA CHAIR WHG6604 22.8"D x 22.9"W x 33"H SLED BASE, MILK SMOOTH WHITE/BLUE C14C STEELCASE THINK CHAIR: UPHOLSTERED BACK/ UPHOLSTERED SEAT; TASK CHAIR #465A300 22-24.25"D X 28.5"W X 37.25-42"H X 16.5-21.5"SH FRAME: PLATINUM WITH POLISHED ALUMINUM BASE UPHOLSTERY: STEELCASE | FOUNDATION; FOGGY NIGHT UPHOLSTERY: STEELCASE | FOUNDATION; FOGGY NIGHT HARD CASTERS WITH ADJUSTABLE ARMS AND ADJUSTABLE LUMBAR C14E STEELCASE THINK CHAIR: MESH BACK/UPHOLSTERED SEAT/FIXED ARM; TASK CHAIR #465A300 22-24.25"D X 28.5"W X 37.25-42"H X 16.5-21.5"SH FRAME: PLATINUM WITH POLISHED ALUMINUM BASE UPHOLSTERY: STEELCASE | FOUNDATION; FOGGY NIGHT UPHOLSTERY: STEELCASE | FOUNDATION; FOGGY NIGHT HARD CASTERS WITH FIXED ARMS AND FIXED LUMBAR C14F STEELCASE THINK CHAIR: MESH BACK/UPHOLSTERED SEAT; TASK CHAIR #465A300 22-24.25"D X 28.5"W X 37.25-42"H X 16.5-21.5"SH FRAME: PLATINUM WITH POLISHED ALUMINUM BASE SEAT UPHOLSTERY: STEELCASE | FOUNDATION - FOGGY NIGHT MESH BACK: NICKEL C14G STEELCASE THINK CHAIR: MESH BACK/UPHOLSTERED SEAT; TASK STOOL 465B300PM 22-24.25"D X 28.5"W X 44-53.75"H X 22.5-32.5"SH FRAME: PLATINUM WITH POLISHED ALUMINUM BASE SEAT UPHOLSTERY: STEELCASE | FOUNDATION - FOGGY NIGHT MESH BACK : NICKEL C16B DAVIS SACHET WITH ARMS SA-1016-PA 26.75" X 27"D X 38.25"H; 18.75"SH POLISHED CHROME, BLACK CASTERS DESIGNTEX - APPLESEED - ZINC DESIGNTEX - APPLESEED - ZINC SACHET C28B OFS HARPIN CHAIR 85215-M 19" X 21" X 35" POLISHED ALUMINUM DESIGNTEX | APPLESEED - ZINC N/A BACK: ASH - BLONDE (MBM) HARD CASTERS (BLACK) C31 STEELCASE PLAYER GUEST CHAIR 475412M TYPICAL 6205 BLACK 5S26 COGENT CONNECT LICORICE 5S26 COGENT CONNECT BLACK GLIDES M1 ESI ESI; SINGLE MONITOR ARM. CLAMP ON WITH CPU HOLDER ESI; SINGLE MONITOR ARM; CPU HOLDER: CPU-TC-USB SILVER M2 ESI ESI; DUAL MONITOR ARM WITH CPU HOLDER ESI; EDGE2-SLV, CLAMP ON; CPU HOLDER: CPU-TC-USB SILVER S10 STEELCASE 1.5H LATERAL BOX/FILE CONFIGURATION WITH RECESSED BACK, COUNTERWEIGHT, COMMON TOP, AND GROMMETS L&R REAR. CRL15H & CRCT 18.875"D X 36"W ARCTIC WHITE ARCTIC WHITE N/A N/A BAR PULL: SILVER; GROMMETS: 7241 ARCTIC WHITE; SURGE PROTECTOR: WHITE, MEDICAL-GRAD E SURGE PROTECTOR S15B STEELCASE 3H UNIVERSAL LATERAL FILE RLF24363F 24"D X 36"W X 40"H ARCTIC WHITE N/A N/A N/A LOCK FINISH POLISHED CHROME NON-STANDARD 24" DEEP 3H LATERAL FILE, STANDARD WHITE METAL FINISH S16A STEELCASE CURRENCY BUFFET CREDENZA CRCDBTO4D 24"D X 60"W X 36"H CLEAR OAK CLEAR OAK N/A N/A OPEN SHELVES, 4 DOORS S18A STEELCASE CURRENCY 30W - CRWDL SPECIAL WARDROBE E2020200 32D X 30W X 60H CLEAR OAK CLEAR OAK SPECIAL WARDROBE, DOUDLE DOOR WITH MOUSE HOLE CUTOUT FOR CORD IN LOWER REAR PANEL, WITH 2" RECESSED BACK PANEL, WITH VENT SLOTS, WITH 2 SHELVES - ONE FIXED, ONE ADJUSTABLE. LOCKING HARDWARE T4 COALESSE AWAIT FREESTANDING SIDE TABLE #46-T2 25"H ARCTIC WHITE PLATINUM GLOSS 4142 T5C STEELCASE WORKSURFACE - STRAIGHT SEE TYPE COMMENTS 24"D X 48"W CLEAR OAK ARCTIC WHITE 1-24X48 WORKSURFACE (USWS) 2-24D UNIVERSAL OPEN LEG (UFQ24T) T6C NEVINS OSCAR SOFT RECTANGLE SR4284AOC1Y0116LPO1 WITH Y-BASE 42" X 84" FORMICA AGED ASH 8844-58 POLISHED CHROME ACT21U INTERACT G2 POWER (2) WITH (2) 15 AMP; (2) RJ45 WITH 1 TO REMAIN OPEN; (2) USB IN SILVER. SEE POWER, VOICE, DATA PLAN FOR POWER OR NO POWER. T6G NEVINS SOFT RECTANGLE SR4284AOC1Y0116LPO1 WITH Y-BASE 42" X 72" FORMICA AGED ASH 8844-58 POLISHED CHROME T7C STEELCASE STEELCASE MIGRATION ADJUSTABLE HEIGHT DESK WITH T-LEG SPECIAL TRAPEZOID: 33"D X 40"D X 66"W; LEG SHROUD: 9"D X 42"W X 21-3/8"H CLEAR OAK ARCTIC WHITE N/A N/A TABLE POWER MODULE: ARCTIC WHITE POWER TO BE DSINTRO, CLAMP ON DESKTOP POWER UNIT, WITH (2) POWER/ (1) USB-A, (1) USB-C. FURNITURE VENDOR TO PROVIDE MEDICAL GRADE SURGE PROTECTOR. T16 STEELCASE UNIVERSAL SQUARE TABLE WITH LEGS FOR ACCESSIBLILITY BFRQ42 TOP; BPL LEGS 42"D X 42"W X 28.5"H CLEAR OAK ARCTIC WHITE W.S9B STEELCASE 2H UNIVERSAL LATERAL FILE, FROM WORKPLACE STANDARD KIT RLF18363F 24"D X 36"W x 28"H ARCTIC WHITE COMMONTOP METAL: ARCTIC WHITE LOCK PLUG: POLISHED CHROME N/A N/A NON-STANDARD 24" DEEP 2H LATERAL FILE, STANDARD WHITE METAL FINISH. ADD RAILS, LOCKING. NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 SD VAULT 111 CASH SAFE 112 MECH/NER 113 SD VAULT CIRCULATION 107 COUPON ROOM 110 COUPON ROOM 109 ATM / NIGHT DROP 106 CONFERENCE 120 WOMEN'S RESTROOM 117 MEN'S RESTROOM 118 BREAKROOM 114 CIRCULATION 116 TELLER LINE 108 ATM 103 ENTRY 101 WAITING 104 LOBBY 102 ENTRY 105 PLATFORMS 121 PLATFORMS 119 STORAGE 115 T5C C31 T5C C31 C14F C3C C3C C14G C14G C14G C14G C14G S15B S15B S15B S16A T16C6A C6A T16 C6A C6A S18A C16B C16B T7C C14C S10M2 M2 S10 C16B C16B T7C M2 M2 S10 C14C S10 C28B C28B T7C M1 S10 C14C C14E C14E C14E C14E C14E C14E C28B C28B T7CM1 S10 C14C C28B C28B T7CM1 S10 C14C C28B C28B T7CM1 S10 C14C C5A T4 C5A C5A T4 C5A 5' - 6"4' - 0"4' - 0" 3' - 0 " 3' - 0 " 1 2 2 2 2 TYP. 2 TYP. 2 TYP. 3 3 3 444 5 5 56 6 6 6 7 TYP. 10 9 W.S9B EQ E Q 8 1 1 5' - 0" 4' - 1" T6G PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:15 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 GROUND FLOOR FURNITURE PLAN i301 101 E Foothill Blvd, Arcadia, CA 91006 GENERAL NOTES - FURNITURE PLAN A. THIS SHEET IS FOR DESIGN INTENT AND MINIMUM AISLE WIDTHS FOR FURNITURE INSTALLATION. REFER TO FURNITURE INSTALLATION DRAWINGS BY LOCAL SERVICE PROVIDER FOR FULL SCOPE OF WORK FOR FURNITURE INSTALLATION. B. FURNITURE VENDOR TO FURNISH ALL LABOR AND MATERIALS / EQUIPMENT AS REQUIRED TO COMPLETE FURNITURE INSTALLATION. C. ALL FURNITURE TO BE PROVIDED BY FURNITURE VENDOR. D. TABLES SHOWN ADJACENT TO A WALL ARE TO BE CENTERED ON WALL, U.N.O. E. COORDINATE WITH FACILITY MANAGER AND US BANK MANAGER FOR REUSE AND RELOCATION OF EQUIPMENT. KEYNOTES - FURNITURE PLAN NO. DESCRIPTION 1 EXISTING FURNITURE AND EQUIPMENT TO REMAIN. NO NEW FURNITURE TO BE PROVIDED IN THIS AREA. 2 FURNITURE VENDOR TO PROVIDE 66"H PANELS WITH ARCTIC WHITE 2730 SKINS INSIDE. FRAME TO BE MILK 4242. OUTSIDE LAMINATE SKINS TO FLOOR TO BE CLEAR OAK 2HAK. 3 FURNITURE VENDOR TO PROVIDE AND INSTALL 24"W PANEL IN LIEU OF STANDARD SIZE TO MEET NEEDED CLEARANCES. 4 WING PANEL TO BE AT 30" HEIGHT. PANEL TO BE 6009 ARCTIC WHITE LAMINATE. FRAME TO BE ARCTIC WHITE. MINIMUM PANEL LENGTH TO BE 24" 5 FURNITURE VENDOR TO PROVIDE AND INSTALL 36"W PANEL IN LIEU OF STANDARD SIZE TO MEET NEEDED CLEARANCES. 6 PROVIDE FINISHED BACKS ON FURNITURE AT FLOOR TO CEILING WINDOWS. 7 FURNITURE VENDOR TO PROVIDE AND INSTALL HARDWARE TO SECURE PANEL TO WALL. 8 LOCATION OF FUTURE ATM. 9 EXISTING FIREPROOF LATERAL FILE TO BE RELOCATEDN AS SHOWN ON PLAN 10 EXISTING EQUIPMENT TO BE RELOCATED AS SHOWN ON PLAN. N 1/4" = 1'-0"1 GROUND FLOOR FURNITURE PLAN NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:18 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 01 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:21 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 02 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:24 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 03 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:27 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 04 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:30 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 05 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:33 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 06 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:36 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 07 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:39 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 08 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:41 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 09 101 E Foothill Blvd, Arcadia, CA 91006 NOTE: ALL SPECS SECTIONS MAY NOT BE USED - REFER TO DRAWINGS NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. Autodesk Docs://US Bank Corporate 2023/A-CA Arcadia Foothill -Lvl 1.rvt 11/12/2025 6:30:43 AM 14854C5247 AWR CK PV 03/19/2025 C34974 11/13/2025 W. Scott Fay 11/30/2027 SPECIFICATIONS SPEC 10 101 E Foothill Blvd, Arcadia, CA 91006 NO. DATE DESCRIPTION W. SCOTT FAY C-34974 RENEWAL DATE ARDCEHSITNEE CC TIL 11/30/2027 J ---- --- - ---- ## X EXISTING TO REMAIN XRP EXISTING LOCATION, NEW DEVICE OR EQUIPMENT TO BE INSTALLED IN PLACE XNP EXISTING LOCATION, NEW DEVICE OR EQUIPMENT HAS BEEN INSTALLED IN PLACE XRL EXISTING TO BE RELOCATED XO EXISTING TO BE REMOVED XNL EXISTING IN NEW LOCATION XRC EXISTING TO BE RECIRCUITED N NEW RENOVATION LEGEND: MOUNTING HEIGHTS FOR DEVICES AND EQUIPMENT TO BE MEASURED FROM FLOOR TO CENTERLINE OF DEVICE. DEVICES EXTENDING GREATER THAN 4" FROM THE WALL SHALL HAVE A MINIMUM MOUNTING HEIGHT OF 80" AFF TO BOTTOM OF DEVICE. SYMBOL LIST NOTE: PANELS: ELECTRICAL PANEL -SURFACE / RECESSED WITHOUT DOOR -SURFACE / RECESSED WITH DOOR -SURFACE / RECESSED DENOTES THE FOLLOWING (INV) INVERTER (LCP) LIGHTING CONTROL PANEL 'XXX''XXX' EQUIPMENT CABINETS: 'XXX''XXX' POWER: SIMPLEX RECEPTACLE -MOUNTED 18" AFF UNLESS NOTED OTHERWISE DUPLEX RECEPTACLE -MOUNTED 18" AFF UNLESS NOTED OTHERWISE XXX DENOTES THE RECEPTACLE TYPE OR EQUIPMENT SERVED (WP) WEATHERPROOF WITH GFI RECEPTACLE X DENOTES CIRCUIT NUMBER DUPLEX RECEPTACLE -GFCI (INDICATED BY CENTER HATCH) -MOUNTED 18" AFF UNLESS NOTED OTHERWISE DUPLEX RECEPTACLE -GFCI -MOUNTED 4" ABOVE COUNTERTOP OR COUNTER BACKSPLASH WHERE PRESENT DUPLEX RECEPTACLE -MOUNTED 4" ABOVE COUNTERTOP OR COUNTER BACKSPLASH WHERE PRESENT QUADRUPLEX RECEPTACLE -MOUNTED 18" AFF UNLESS NOTED OTHERWISE QUADRUPLEX RECEPTACLE -GFCI (INDICATED BY CENTER HATCH) - MOUNTED 18" AFF UNLESS NOTED OTHERWISE QUADRUPLEX RECEPTACLE -MOUNTED 4" ABOVE COUNTERTOP OR COUNTER BACKSPLASH WHERE PRESENT X XXX JUNCTION BOX (ELECTRICAL CONNECTION) GENERAL: DRAWING KEYNOTE SYMBOL BUILDING SECTION BUILDING ELEVATION CALLOUT BOUNDARY VIEW REFERENCE CALLOUT MOUNTING HEIGHT DESIGNATION DETAIL NUMBER SHEET NUMBER DETAIL NUMBER DETAIL NUMBER SHEET NUMBER SHEET NUMBER +X' -X" /---- DETAIL NUMBER SHEET NUMBER TECHNOLOGY: TECHNOLOGY OUTLET WITH BACKBOX, CONDUIT, AND TWO DEVICES AND CABLES. 4" ABOVE COUNTER/COUNTER BACKSPLASH WHERE PRESENT. TECHNOLOGY OUTLET WITH BACKBOX, CONDUIT, AND TWO DEVICES AND CABLES. 18" AFF UNLESS NOTED OTHERWISE. TECHNOLOGY OUTLET WITH BACKBOX, CONDUIT, AND TWO DEVICES AND CABLES. FURNITURE MOUNTED. #D IF NOTED, #DENOTES QUANTITY D DENOTES DEVICE TYPE #D #D A/E ARCHITECT/ENGINEER ABV ABOVE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AVAILABLE INTERRUPTING CURRENT ALT ALTERNATE ALT SW ALTERNATOR SWITCH ARCH ARCHITECT ATS AUTOMATIC TRANSFER SWITCH BFG BELOW FINAL GRADE BKR BREAKER BLDG BUILDING BOL BUILT IN OVERLOAD BPC BOLTED PRESSURE CONTACT SWITCH CATV CABLE TELEVISION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING CP CONTROL PANEL CS COMBINATION STARTER CT CURRENT TRANSFORMER DE DUAL ELEMENT FUSES DIR DIRECT DISC DISCONNECT DN DOWN EC ELECTRICAL CONTRACTOR ELEV ELEVATION REFERENCE EM EMERGENCY EMT ELECTRIC METALLIC TUBING ENT ELECTRICAL NON-METALLIC TUBING EOL END OF LINE RESISTOR EP EXPLOSION PROOF EWC ELECTRIC WATER COOLER F FLUSH FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHERS FDR FEEDER FIXT FIXTURE FLA FULL LOAD AMPS FLR FLOOR FLUOR FLUORESCENT FS FLOW SWITCH FVNR FULL VOLTAGE NON-REVERSING GC GENERAL CONTRACTOR GFI GROUND FAULT INTERRUPTER GRC GALVANIZED RIGID CONDUIT GRD GROUND GYP GYPSUM BOARD HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTO SWITCH HP HORSEPOWER HPS HIGH PRESSURE SODIUM HV HIGH VOLTAGE HVAC HEATING & VENTILATING -AIR CONDITIONING HVC HEATING VENTILATING CONTRACTOR HW HEAVYWALL ID INDIRECT IL INTERLOCK IMC INTERMEDIATE METAL CONDUIT INC INCANDESCENT IU IN UNIT J-BOX JUNCTION BOX LG LAY-IN GRID LTG LIGHTING LV LOW VOLTAGE LVT LINE VOLTAGE THERMOSTAT MAG MAGNETIC STARTER MAN MANUAL STARTER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MLO MAIN LUGS ONLY MSB MAIN SWITCHBOARD MTD MOUNTED NIC NOT IN CONTRACT NU NEAR UNIT OU ON UNIT P POLE PB PUSH BUTTON PC PHOTO CONTROL PE SW PNEUMATIC SWITCH PEND PENDANT PLBG PLUMBING CONTRACTOR PNL PANEL R RELAY REC RECESS RECEPT RECEPTACLE RM ROOM RVS REDUCED VOLTAGE STARTING S SPLINE SEL SW SELECTOR SWITCH SP SW SPEED SWITCH SURF SURFACE SW SWITCH TC TIME CLOCK TCC TEMPERATURE CONTROL CONTRACTOR TCP TEMPERATURE CONTROL PANEL TS TAMPER SWITCH TYP TYPICAL UG UNDERGROUND UNIV UNIVERSAL UNO UNLESS NOTED OTHERWISE USS UNIT SUBSTATION WP WEATHERPROOF XFMR TRANSFORMER ELECTRICAL ABBREVIATIONS GENERAL NOTES: 1. THIS INSTALLATION SHALL BE IN COMPLIANCE WITH THE 2022 CALIFORNIA ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2. BEFORE COMMENCING WORK THE CONTRACTOR SHALL VISIT THE JOB SITE AND FULLY INFORM THEMSELVES OF ALL CONDITIONS THAT AFFECT THE WORK, EXAMINE THE DRAWINGS AND SPECIFICATIONS, AND SUBMIT ANY QUESTIONS IN WRITING TO THE ENGINEER. 3. ALL ELECTRICAL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE PROJECT SPECIFICATIONS AND ALL OTHER DRAWINGS RELATED TO THE PERFORMANCE OF THE WORK. 4. THE CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THIS WORK SHALL BECOME THOROUGHLY FAMILIAR WITH THE PROJECT SPECIFICATIONS BEFORE COMMENCING ANY WORK. THE PROJECT SPECIFICATIONS AND DRAWINGS FORM THE BASIS OF THIS CONTRACT REQUIREMENTS AND INCLUDE THE TYPE AND GRADE OF MATERIALS TO BE INSTALLED, EQUIPMENT TO BE FURNISHED, THE MANNER BY WHICH TO BE INSTALLED AND WHERE TO BE LOCATED. IN THE EVENT OF A CONFLICT BETWEEN THE PROJECT SPECIFICATIONS AND DRAWINGS, SPECIFICATIONS GOVERN UNLESS THE ARCHITECT/ENGINEER DIRECTS OTHERWISE. 5. THE ELECTRICAL CONTRACTOR SHALL CHECK CAREFULLY ALL CONSTRUCTION DRAWINGS AND SPECIFICATIONS THAT ARE PART OF THIS PROJECT TO ENSURE THAT NO FIXTURE, OUTLET, ALARM STATION, OR CONTROL AND POWER WIRING IS OMITTED. HE SHALL CONSULT ALL TRADES FURNISHING EQUIPMENT AND OBTAIN FROM THEM ALL DATA. IN SOME CASES EQUIPMENT, FIXTURES AND DEVICES ARE SHOWN ONLY. ASCERTAIN AND PROVIDE THE WIRING AND CONTROL STATIONS REQUIRED FOR THE PROPER FUNCTION OF BUILDING EQUIPMENT. NO EXTRA CHARGES SHALL BE ACCEPTED BY OWNER AFTER BIDDING FOR SUCH EQUIPMENT AND LABOR. 6. EQUIPMENT LABELS AND INSTRUCTIONS REGARDING THE APPLICATION AND INSTALLATION OF THE LISTED EQUIPMENT SHALL BE FOLLOWED TO INSURE THAT THE EQUIPMENT IS BEING INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S LISTING INSTRUCTIONS. THE TEMPERATURE RATING OF THE EQUIPMENT TERMINATIONS MUST BE CAREFULLY CORRELATED WITH THE CONDUCTOR AMPACITY TO PREVENT OVERHEATING AND PREMATURE FAILURE. 7. INSTALL ELECTRICAL DEVICES AS INDICATED IN THIS SET OF DRAWINGS. ADJUST FINAL DEVICE LOCATIONS AS REQUIRED TO ACCOMMODATE WORK. COORDINATE WITH ALL TRADES INVOLVED AND WITH ARCHITECTURAL CASEWORK AND ELEVATIONS DRAWINGS. NOTIFY THE ENGINEER AND/OR THE ARCHITECT IF ANY CONFLICTS ARE FOUND PRIOR TO BIDDING PROJECT. INSTALL CONDUIT AND BOXES TO CLEAR EMBEDDED DUCTS, OPENINGS AND OTHER STRUCTURAL FEATURES. 8. ALL WORK IS TO BE DONE IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE APPLICABLE CODES AND REGULATIONS. 9. ALL LIGHTING FIXTURES ARE TO BE LOCATED AS REQUIRED ON THE JOB TO CLEAR DUCTS, PIPING, EQUIPMENT, AND/OR MECHANICAL UNITS. 10. CONDUIT RUNS SHOWN ON DRAWINGS ARE DIAGRAMMATIC. ALL CONDUITS SHALL RUN CONCEALED, EXCEPT IN EQUIPMENT ROOMS AND WHERE APPROVED BY ARCHITECT OR AS INDICATED ON DRAWING. 11. FURNISH AND INSTALL EQUIPMENT DISCONNECT SWITCHES IN STRICT COMPLIANCE WITH CODE REQUIREMENTS. 12. ADJACENT POWER AND DATA/TELE DEVICES SHALL BE SPACED NO MORE THAN 4" APART. PROVIDE JUNCTION BOX MOUNTING BRACKET BETWEEN STUDS AS NEEDED. 13. ALL RECEPTACLES, TELEPHONE, AND DATA OUTLETS SHALL BE MOUNTED PER MOUNTING HEIGHT LEGEND OR TO MATCH BUILDING STANDARD (WHEN APPLICABLE), UNLESS OTHERWISE NOTED. ALL DEVICES SHALL BE NEW UNLESS OTHERWISE NOTED. 14. ALL FIRE ALARM NOTIFICATION DEVICES SHALL BE MOUNTED AT 80" AFF IN ACCORDANCE WITH ADA, UNLESS OTHERWISE NOTED. 15. DETERMINE, IN ADVANCE OF PURCHASE, THAT ALL ELECTRICAL MATERIALS AND EQUIPMENT TO BE INSTALLED SHALL FIT INTO THE ROOM OR SPACE ALLOCATED, AS INDICATED ON THE DRAWINGS, ALLOWING SUFFICIENT CLEARANCE FOR THE SAFE SERVICE AND/OR MAINTENANCE OF RELATED EQUIPMENT, INCLUDING THAT OF OTHER TRADES. 16. ALL CIRCUITS SHALL HAVE AN EQUIPMENT GROUNDING CONDUCTOR INSTALLED. COLOR OF GROUNDING CONDUCTOR SHALL BE GREEN. SIZE OF GROUNDING CONDUCTOR SHALL BE AS REQUIRED PER LOCAL CODE. 17. ALL BRANCH CIRCUITS SHALL HAVE A DEDICATED NEUTRAL CONDUCTOR INSTALLED. COLOR OF NEUTRAL CONDUCTOR SHALL BE WHITE FOR 120/240V AND GREY FOR 480/277V CIRCUITS. 18. ALL CONDUCTORS SHALL BE MADE OF COPPER. MINIMUM WIRE SIZE SHALL BE #12AWG UNLESS OTHERWISE INDICATED. UTILIZE SOLID CONDUCTORS FOR WIRE GAUGES UP TO #12AWG AND STRANDED CONDUCTOR FOR GAUGES #10AWG AND LARGER. 19. SPECIAL RECEPTACLES PLUG CONFIGURATION REQUIREMENTS SHALL BE COORDINATED WITH EQUIPMENT PLUG REQUIREMENTS PRIOR TO INSTALLATION. 20. ALL FEEDER AND BRANCH CIRCUIT WIRING INSTALLED INDOORS SHALL USE THHN INSULATION. ALL WIRING INSTALLED OUTDOORS SHALL USE THWN INSULATION. REFER TO SPECIFICATION DOCUMENTS FOR COLOR CODED REQUIREMENTS. 21. ALL POWER WIRING SHALL BE INSTALLED IN A DEDICATED RACEWAY SYSTEM. MINIMUM RACEWAY SIZE SHALL BE 3/4"C UNLESS OTHERWISE INDICATED. CONTRACTOR SHALL SIZE ALL CONDUITS SO AS TO NOT EXCEED 40% OF CONDUIT FILLING CAPACITY PER LOCAL CODE. 22. ALL PULL BOXES AND JUNCTION BOXES SHALL BE SIZED PER NEC. BASED ON THE AMOUNT OF CABLE AND CONDUITS ENTERING/LEAVING THE BOX. 23. ALL BREAKERS SERVING FIRE ALARM AND EXIT SIGNS EQUIPMENT SHALL BE KEY-LOCK STYLE. 24. SERVICE EQUIPMENT AND BRANCH CIRCUIT PANELBOARDS SHALL HAVE AN UPDATED PANEL DIRECTORY INSTALLED UPON PROJECT COMPLETION. UTILIZE TYPE WRITER AS A MINIMUM FOR COMPLIANCE. HAND WRITTEN CARD DIRECTORIES ARE NOT ACCEPTABLE. 25. ALL FINAL CONNECTIONS TO MOTORS AND VIBRATING EQUIPMENT SHALL BE DONE WITH LIQUID TIGHT FLEXIBLE METAL CONDUIT. INSTALL GREEN GROUNDING CONDUCTOR. 26. E.C. SHALL COORDINATE WITH HVAC CONTRACTOR EXACT POINT OF CONNECTION TO MECHANICAL UNIT PRIOR TO ROUGH-IN. E.C. SHALL ALSO VERIFY EXACT BREAKER SIZE AND WIRING WITH APPROVED MECHANICAL UNITS SHOP DRAWINGS PRIOR TO INSTALLATION. 27. SERVICE EQUIPMENT, BRANCH CIRCUIT PANELBOARDS, METER SOCKETS SHALL HAVE AN "ARC- FLASH HAZARD WARNING" LABEL INSTALLED. LABEL SHALL BE CLEARLY VISIBLE TO PERSONNEL. 28. SERVICE EQUIPMENT AND PANELBOARDS SHALL BE LABELED WITH A READILY VISIBLE LABEL PER NFPA STANDARD FOR SAFETY IN THE WORKPLACE, LABEL SHALL READ CAUTION ARC FLASH HAZARD". SIZE AND COLOR OF TEXT SHALL BE PER STANDARD. 29. ALL EQUIPMENT INSTALLED OUTSIDE SHALL BE WEATHER PROOF RATED. REFER TO DRAWINGS FOR ADDITIONAL INFORMATION. 30. INSTALL CONDUIT FROM THE TOP OF THE BAR JOIST. 31. LABEL ALL J-BOX COVER PLATES AND RECEPTACLE COVER PLATES WITH CIRCUIT INFORMATION. PROVIDE A TYPED LABEL, MARKER IS NOT ACCEPTABLE. 32. E.C. SHALL FURNISH AND INSTALL J-BOX AND 1/2"C FOR MECHANICAL THERMOSTAT. COORDINATE FINAL LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. 33. ALL NEW ELECTRICAL PANELS SHALL BE BOLT-ON TYPE CIRCUIT BREAKERS. 34. ALL CABLE LOCATED WITHIN CEILING SPACES USED FOR PLENUM AIR RETURN SHALL BE PLENUM RATED OR RUN IN CONDUIT. 35. LOW VOLTAGE WIRING (PHONE/DATA, LIGHTING CONTROLS, SECURITY, THERMOSTATS, ETC.) LOCATED IN NON-ACCESSIBLE WALLS, CEILING SPACES, AND IN OPEN CEILING AREAS PRONE TO DAMAGE SHALL BE IN CONDUIT. 36. OUTLETS, RECEPTACLE COVER PLATES, AND LIGHT SWITCHES TO BE WHITE IN COLOR, U.N.O. ALL EXISTING OUTLETS, COVER PLATES, AND LIGHT SWITCHES TO BE REPLACED WITH WHITE, U.N.O. GENERAL DEMOLITION NOTES: 1. EACH CONTRACTOR SHALL REVIEW THE EXISTING SYSTEMS IN THE FIELD ALONG WITH BID DOCUMENTS AND DETERMINE SELECTIVE DEMO AND ADDITION OF TEMPORARY SYSTEMS (IF REQUIRED) TO MAKE PHASED DEMO AND PROPOSED REMODELING. IT SHALL ASSURE UNINTERRUPTED SAFE OPERATION OF AREAS THAT ARE AFFECTED BY DEMO AND ADDITION OF PROPOSED SYSTEMS AS ALL TIMES. INCLUDE THE NECESSARY WORK TO ACCOMPLISH THIS AND COORDINATE PHASING ACCORDINGLY. 2. CONFIRM WITH THE MANUFACTURERS OF EXISTING EQUIPMENT THAT IS TO BE REUSED OR EXTENDED. 3. WHERE EXISTING ELECTRICAL WORK PREVENTS PROPER CONSTRUCTION OF NEW WORK AS INDICATED, REMOVE, REROUTE, RELOCATE, OR IN OTHERWAYS ALTER EXISTING WORK IN ORDER TO ACCOMMODATE. 4. WHERE EXISTING CONDUIT, WIRE SUPPORTS, HANGERS AND OTHER ELECTRICAL WORK MUST BE REMOVED AS A RESULT OF THE ALTERATIONS, THEY SHALL BE COMPLETELY REMOVED, BACK TO THE FIRST OUTLET WHICH IS LEFT UNAFFECTED BY THE DEMOLITION. CONDUIT WHICH IS BURIED IN CONCRETE OR OTHERWISE INACCESSIBLY POSITIONED MAY BE ABANDONED. IN SUCH CASES, WIRE SHALL BE PULLED OUT AND THE CONDUIT SHALL BE PLUGGED AT EACH END. 5. EXISTING ELECTRICAL MATERIALS AND EQUIPMENT, INCLUDING LIGHTING FIXTURES, SWITCHES, RECEPTACLES, SIGNAL LIGHTS, SPEAKERS, INTERCOM EQUIPMENT, CONTROLS, CONDUIT OUTLETS, FITTINGS, AND OTHER DEVICES REMOVED AS A RESULT OF THE ALTERATIONS SHALL REMAIN THE PROPERTY OF THE OWNER (UNLESS OTHERWISE INDICATED) AND SHALL BE REUSED WHERE INDICATED. 6. EXAMINE THE CONDITION OF ANY SUCH MATERIALS AND EQUIPMENT TO MAKE A PRIOR DETERMINATION OF WHETHER IT IS SUITABLE FOR REUSE. PRESENT FINDINGS TO THE ENGINEER WHO WILL IN TURN MAKE THE FINAL DECISION REGARDING REUSABILITY. ALL WIRE AND CABLE FOR REUSED AND RELOCATED EQUIPMENT SHALL BE NEW. 7. IN ORDER TO COORDINATE THE WORK OF THE MECHANICAL AND ELECTRICAL TRADES, REMOVE EXISTING ELECTRICAL WORK IN AND ABOVE CEILING OF THESE AREAS (AS REQUIRED), AFTER WHICH INSTALL NEW WORK AND REINSTALL EXISTING WORK TO REMAIN, AS SHOWN ON THE DRAWINGS. EXISTING MATERIALS AND EQUIPMENT SHALL BE REUSED ONLY WHERE INDICATED. 8. SOME EXCEPTIONS MAY ARISE WHEREIN EQUIPMENT, EITHER IN ALTERED AREAS OR OTHER AREAS, MUST BE KEPT IN SERVICE, REQUIRING THAT FEEDERS, SIGNAL CONDUCTORS, CONDUITS, BOXES, ETC. SERVING SAME ALSO BE KEPT IN SERVICE. IN SUCH CASES, THOSE ELECTRICAL FEEDERS, SIGNAL CONDUCTORS, CONDUITS, ETC. SHALL BE REROUTED AND RECONNECTED BEFORE PRESENT WORK IS REMOVED. IF THIS IS NOT POSSIBLE, TEMPORARY WIRING SHALL BE PROVIDED, AFTER WHICH NEW WORK SHALL BE INSTALLED AND TEMPORARY WIRING REMOVED. 9. ANY ELECTRICAL EQUIPMENT THAT IS TAGGED TO BE DISPOSED OF SHALL BE DONE PER APPROVED METHOD IN ACCORDANCE WITH THE CONSTRUCTION PLAN AND LOCAL AUTHORITIES. 10. THIS DRAWING INDICATES AREAS THAT ARE BEING AFFECTED BY THE DEMOLITION. DASHED LINES SHOW EXISTING MATERIALS AND EQUIPMENT TO BE REMOVED SOLID LINES SHOW EXISTING MATERIALS AND EQUIPMENT TO REMAIN. ELECTRICAL CONTRACTOR SHALL REMOVE ALL ELECTRICAL EQUIPMENT AFFECTED BY THE DEMOLITION AND WILL KEEP REMAINING EQUIPMENT CONNECTED, POWERED TO THE EXISTING CIRCUITS AS REQUIRED. 11. THIS DRAWING SHOWS A REPRESENTATIVE SAMPLE OF DEMOLITION WORK THAT IS TO TAKE PLACE. NOTE THAT NOT EVERY DEVICE, LIGHTING FIXTURE, CONDUIT ETC. REQUIRED TO BE DEMOLISHED IS NECESSARILY INDICATED ON THIS PLAN. THE CONTRACTOR SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH THE EXTENT OF EXISTING WORK TO BE DEMOLISHED. 12. ALL PROPOSED DEMOLITION WORK SHALL BE THOROUGHLY COORDINATED WITH ALL OTHER TRADES. 13. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS, FEEDERS, AND BRANCH CIRCUITS PASSING THROUGH RENOVATED AREA AND SERVING UNDISTURBED AREAS. 14. ANY PORTION OF THE EXISTING CONDUIT SYSTEM THAT IS TO BE REUSED FOR THE NEW INSTALLATION SHALL BE CHECKED TO ENSURE THAT IT IS CLEAN, FREE OF DAMAGE, FREE OF CORROSION, AND ADEQUATELY SUPPORTED. 15. DISCONNECT AND REMOVE ALL ELECTRICAL EQUIPMENT, DEVICES AND CONDUITS IN WALLS, FLOORS AND CEILING SCHEDULED FOR DEMOLITION. 16. EXISTING ELECTRICAL SYSTEM IS DESCRIBED BASED ON SURVEYS OF EXISTING CONDITIONS THAT ARE VISIBLE DURING THE DESIGN PHASE. CONTRACTOR SHALL CONFIRM ALL SERVICES PRIOR TO PROCEEDING WITH DEMOLITION. 17. PATCH ALL HOLES IN SLABS, WALLS AND CEILING WHERE ELECTRICAL DEVICES AND/OR CONDUIT ARE REMOVED. IF THE REMOVAL OF CONDUIT, BOXES, EQUIPMENT, ETC. COMPROMISES THE FIRE RATING OF THESE ITEMS, THE CONTRACTOR SHALL SEAL OPENINGS WITH CODE APPROVED FIRE STOPPING MATERIAL. 18. WHERE FEEDERS OR BRANCH CIRCUITS ARE DISCONNECTED AND REMOVED FROM EXISTING PANEL BOARDS, CONTRACTOR SHALL MARK THE AFFECTED BREAKERS IN THOSE PANEL BOARDS AS "SPARE". INSTALL NEW KNOCK-OUT BLANK INSERT IN PANEL BOX. 19. CONTRACTOR IS TO PERFORM DEMOLITION WORK IN A NEAT, SKILLFUL, AND CAREFUL MANNER SO AS NOT TO DAMAGE OR DEFACE EXISTING CONSTRUCTION THAT IS TO REMAIN. 20. VERIFY THAT REMOVAL OF DEVICES IN RENOVATED AREA DOES NOT AFFECT DEVICES IN OTHER AREAS THAT MAY BE FED FROM THE CIRCUIT BEING DISCONNECTED. FIRE ALARM DEFERRAL NOTES: RTM IS NOT THE ENGINEER OF RECORD FOR FIRE ALARM. THE ELECTRICAL CONTRACTOR SHALL INCLUDE A PRICE IN THE ELECTRICAL BID FOR LANDLORD APPROVED MODIFICATIONS TO THE EXISTING FIRE ALARM SYSTEM, INCLUDING PLANS AND ALL ASSOCIATED DOCUMENTS AS REQUIRED BY LOCAL CODES. THESE SHALL BE SUBMITTED TO THE LOCAL AUTHORITIES BY A QUALIFIED AND LICENSED DESIGN- BUILD FIRE ALARM CONTRACTOR FOR A COMPLETE AND APPROVED FIRE ALARM SYSTEM. THE PLANS SHALL BE SIGNED AND SEALED BY THE FIRE ALARM ENGINEER OF RECORD AND SUBMITTED FOR PLAN REVIEW PRIOR TO RECEIVING SPECIFIC PERMITS FOR THIS WORK. THE FIRE ALARM CONTRACTOR SHALL ALSO SUBMIT ALL SHOP DRAWINGS, BATTERY CALCULATIONS, SPECIFICATION SHEETS, ETC. AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION TO THEIR LOCAL DESIGN ENGINEER FOR REVIEW AND APPROVAL. IF SHOWN LOCATIONS AND NUMBER OF DEVICES ARE SUGGESTED ONLY. SCOPE OF WORK PROJECT SQUARE FOOTAGE: 3,821 SQFT PROJECT BUILDING TYPE: BUSINESS GROUP B, FINANCIAL INSTITUTION PROJECT INCLUDES: 1. NEW ELECTRICAL DEVICES TO SUPPORT NEW ADMINISTRATION EQUIPMENT AND WORKSTATIONS. 2. NEW CIRCUIT BREAKERES TO SUPPLY POWER FOR NEW DEVICES BASED ON FLOOR PLAN. Engineering Consultants, LLC PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. 5137 Utica Ridge Road | Davenport, IA 52807 T: 563.726.6310 : www.rtmec.com Autodesk Docs://US Bank Corporate 2023/RTM-USB-CA-Arcadias-6354.rvt 12/17/2025 2:59:45 PM 14854C5247 JG AM 12/17/2025 E13453 12/17/2025 RANDALL MOSS 09/30/2026 ELECTRICAL GENERAL NOTES AND SYMBOLS E000 101 E Foothill Blvd, Arcadia, CA 91006 ELECTRICAL SHEET INDEX SHEET NO. SHEET NAME E000 ELECTRICAL GENERAL NOTES AND SYMBOLS E001 ELECTRICAL SPECIFICATIONS E101 ELECTRICAL POWER PLAN ED101 ELECTRICAL DEMOLITION POWER PLAN NO. DATE DESCRIPTION 11/13/2025 ISSUE FOR PERMIT 1 12/17/2025 PLAN REVIEW COMMENTS 1 PART 1 -GENERAL 1.1 General Conditions A. The General, Special, and Other Conditions of the Architectural, Mechanical and Vendor documents shall be considered an integral part of these Electrical Specifications. B. Reference to “Contractor” in this specification shall mean “Electrical Contractor (EC)”, unless otherwise noted. All work specified herein is the responsibility of the Electrical Contractor unless specifically noted otherwise. 1.2 Scope of Work A. Furnish all labor, materials, equipment, tools, and other items necessary for, or incidental to, installation of a complete electrical system as required for this project. B. Also include all other work and miscellaneous equipment not specifically mentioned, but reasonably inferred, that are required for a fully functional and tested system. 1.3 Drawings and Documents A. The Drawings and Specifications form a complete set of plans for the electrical work for this project. What is required by either shall be as binding as if required by both. In the event the Drawings and Specifications are in conflict, the greater requirement or cost shall be included in bid, or if time, a clarification will be issued. B. Bidders shall examine and include all other trade and equipment Vendor Drawings and Specifications to avoid omissions, duplications, and to insure complete installation of all work for electrical. C. The Electrical Drawings are diagrammatic and are intended to show approximate location only. Placement of electrical equipment and devices shall not interfere with locations or clearances of other trades' materials or equipment. Coordinate the placement of electrical devices with Architectural plans, elevations and details. D. The direct routing of conduits and wiring is not assured. Exact requirements shall be governed by the conditions of the project site. Extra lengths of wiring or the addition of pull or junction boxes, etc., necessitated by such conditions, shall be included in the Bid. 1.4 Codes, Inspections, and Fees A. The completed electrical installation shall comply with the latest edition of the California Electrical Code as well as all applicable Federal, State, and Local Codes, Regulations, and standards including interpretations by appropriate Authorities Having Jurisdiction. Where the Drawings and Specifications call for workmanship or materials in excess of code or regulatory requirements, the Drawings and Specifications shall govern. B. The work specified herein shall be subject to inspection and approval by authorized representatives of the National Board of Fire Underwriters, State and Local Authorities Having Jurisdiction, and the Engineer. The Contractor shall make the necessary arrangements to have the electrical work inspected by appropriate inspector(s) and shall provide two (2) copies of final signed “Certificate of Inspection” to the Owner. C. Obtain and pay for all licenses, permits, fees and charges for all work installed by the Contractor. Contractor is responsible to pay all fees and charges levied by the Electric Utility Company for connection to electric services. 1.5 Job Site Safety A. The Contractor is solely and completely responsible for conditions of the job site, including safety of all persons and property during performance of work. This requirement will apply continuously and not be limited to normal working hours. B. No act, drawing review or construction review by the Owner, the Engineers or their Consultants, is intended to include review of the adequacy of the Contractor's safety measures in, on, or near the construction site. 1.6 Conditions at the Site A. Examine the site and be familiar with all existing building conditions and limitations prior to submitting bid. No extra payment will be allowed for work required because of these conditions, or if information is visible or readily attainable, for any limitation or misunderstanding of existing conditions. B. Any discrepancies from these documents should be reported to the Architect/Engineer prior to bid. 1.7 Workmanship and Contractor Qualifications A. Install electrical equipment and materials in a neat and workmanlike manner by persons experienced and skilled in the trade. Only the best quality workmanship will be accepted. Haphazard or poor installation will be cause for rejection of work. All exposed components of the electrical systems shall be square and true with building lines and surfaces. B. Contractor shall be licensed in the state in which the project is located. 1.8 Coordination of Work A. Give careful consideration to the work of the general, mechanical and all other contractors/subcontractors on the project. Organize and phase the electrical work so that it will not interfere with the work of other trades. B. Drawings and Specifications for other trades and general construction drawings shall be consulted for coordination information, details, dimensions, etc. Coordinate all shafts, chases, furred spaces, suspended ceiling, locations of equipment, etc. C. The location of all outlets, wiring, and equipment shall be verified. The electrical requirements of any equipment shall be verified with actual equipment or approved Shop Drawings prior to any rough in work. Notify Engineer of any discrepancies. D. Dimensions given on the Drawings shall take precedence over scaled dimensions. Dimensions, whether calculated or scaled, shall be verified in the field. E. Check actual job conditions before fabricating work. Coordinate with other trades to avoid rework due to field conditions. Changes or additions, subject to additional compensation, which are made without written authorization and an agreed price, shall be at the Contractor's risk and expense. F. Coordinate routing of all conduit and wire concealed in walls, soffits or ceilings provided by the General Contractor. Field coordinate all work to conceal installations not coordinated or specifically approved by the Architect and Engineer. G. Verify items such as door swings, window locations, casework, etc., before installing any electrical equipment or devices. H. Make minor adjustments to work where requested by the Owner or the Owner's representative when adjustments are necessary for proper operation and within the intent of the contract. 1.9 Materials and Equipment A. Unless otherwise specified, all material and equipment shall be new and manufactured by approved or listed manufacturers. All materials and equipment shall meet the requirements of all governing codes. B. All material and equipment shall be listed and labeled by Underwriters Laboratories, Inc. (UL), as conforming to its standards in every case where such a standard has been established for that type of material or equipment. C. Obtain written approval within 7 days prior to bid, to use any proposed substitute material or equipment before contracting to purchase such substitutes. The Owner reserves the right to require the removal of any material or equipment which does not have this written approval and which does not comply with the Specifications, regardless of the state of installation of such equipment. D. Where equipment supplied by the Contractor has characteristics other than as specified herein, the Contractor shall, at no additional cost to the Owner, remove and replace the electrical work necessitated by the substituted product. 1.10 Demolition A. Where electrical work to remain is damaged or disturbed in the course of the work, remove damaged portions and install new products of equal capacity, quality, and functionality. B. Accessible work indicated to be demolished: Remove exposed electrical installation in its entirety. C. Abandoned work: Cut and remove buried raceway and wiring indicated to be abandoned in place 2 inches below the surface of adjacent construction. Cap and patch surface to match existing finish. D. Removal: Remove demolished material from the project site. E. Temporary disconnection: Remove, store, clean, reinstall, reconnect, and make operational components indicated for relocation. 1.11 Cutting and Patching A. Perform all core drilling, cutting and patching necessary for the completion of the electrical work for this project. No structural members shall be disturbed without obtaining written permission of the Engineer. B. Any surface which is disturbed in any way by the Contractor shall be repaired and refinished to provide a surface equal in strength, durability, and appearance to the original surface. C. Where it is necessary to drill or cut concrete surfaces, the edges shall be sharply defined. Holes shall be made with a rotary drill. Cuts shall be made with a concrete saw unless some other method of making specific cuts is approved by the Engineer. D. Penetrations through smoke, fire, hazardous area, or other rated separations shall be fire sealed to preserve the ratings of the separations. E. All cutting, drilling, patching, repairing, and refinishing shall be done by persons skilled in appropriate trades. F. Clean away all rubbish and litter generated during electrical installation. 1.12 Maintenance Manual and Record Drawings A. Furnish the Owner with two (2) printed copies and two (2) digital data DVD's of a manual covering the operation and maintenance of all equipment provided under this contract The manuals shall be in a 3- ring, loose leaf, heavy duty binder and submitted to the Architect/Engineer for approval. Each manual shall contain the following: 1. Complete manufacturer catalog data, manufacturer's literature, wiring diagrams, detailed operating instructions, and a complete listing of suppliers and distributors where replacement parts and maintenance services are available for all equipment. 2. Physical description and installation instructions and user's manual and operating instructions. 3. Replaceable parts list. Include replacement lamps per fixture type. 4. Inspection certificates, signed by the appropriate inspector, shall be furnished in the maintenance manual. 5. Manufacturer's warranty. 6. Data DVD with indexed PDF documents of all the manual content of items 1-5 above. B. Markup a set of construction documents as work progresses, to show actual circuit routing with dimensioned information, sizes types, etc., equipment location changes, and any other changes or deviations between project work, as built, and the contract documents. Markings shall be neat, legible, and permanent. Upon completion of the work, the Contractor shall transfer applicable markings to second set of documents and provide both sets of record documents to the Owner. 1.13 Clean-Up A. Rid the premises of scrap materials, trash and debris both during construction and at completion of project. Leave the building and surrounding area in a clean and orderly condition. 1.14 Acceptance Demonstration and Training A. Perform system start-up, testing and programming prior to Owner's training. Do not schedule demonstrations until systems are completely ready to turn over to the Owner as final. B. Demonstrate to the Owner the operation of the electrical installations, including any and all special items installed by EC or installed under EC supervision. The timing of the demonstration will be determined by the Owner upon completion of the work. Properly set automatic time switches to perform switching operations in accordance with schedules provided by the Owner's Representative, and demonstrate (using the manufacturer's operating instructions) how to override, test and program lighting/systems. 1.15 Rebate Programs A. Provide the Owner with all rebate forms, filled out with applicable project information, for utility or product rebate programs to which the Owner is eligible. 1.16 Guarantees and Warranties A. Furnish the Owner with a written guarantee for the period of one (1) year against the failure of any part of the electrical systems installed under the Specifications due to faulty material or workmanship, without any charges, to the Owner. Guarantee period to start upon substantial completion or as specified under general and special conditions. Lamps shall be operable on the start date of, but excluded from, the guarantee. B. Assure that any extended warranties to which the Owner is eligible, are passed on to the Owner. PART 2 -PRODUCTS 2.1 Material Approval A. All materials must be new and bear Underwriter's Laboratories (UL) label. Materials that are not covered by UL testing standards shall be tested and approved by an independent testing laboratory or a governmental agency. Material not in accordance with these Specifications may be rejected either before or after installation. 2.2 Conductors and Cables A. Electrical conductors shall be building wire, except where other type of wire or cable is specifically indicated. B. Building wire conductors shall be soft-drawn annealed copper, having a conductivity of not less than 98% pure copper. Conductor sizes are American Wire Gauge (AWG) or circular mils (KCMIL) as follows: 1. #12 AWG and smaller shall be solid copper. 2. #10 AWG and larger shall be stranded copper. 3. Branch circuits to be color coded, color impregnated wire. C. Insulation type: XHHW, XHHW-2, THHN, or THWN-2, color coded, color impregnated wire. D. AC, core clad or Romex cables are not allowed. Type MC cables with green ground conductor allowed only where noted in Part 3 Execution. E. Light fixtures shall not be used as a raceway unless listed and marked as a raceway in accordance with CEC Article 410.64 and as noted in Part 3 - Execution. F. Electrical conduit installations must be supported per the CEC and not exceed 10 feet between supports. Electrical conduit installations must be a minimum of ¾” EMT. G. Cord Drops and Portable Appliance Connections: Type SO, oil proof, hard service cord with stainless- steel, wire-mesh, strain relief device at terminations to suit application. 2.3 Low Voltage Conductors and Cables A. UTP cable: Category 6, 100-ohm, four-pair. Listed and Labeled by an NRTL acceptable to Authorities Having Jurisdiction as complying with UL 444 and NFPA 70. UTP Cable Connecting Hardware: IDC type, using modules designed for punch-down caps or tools. Cables shall be terminated with connecting hardware of the same category or higher. Plenum rated. B. RS-232 Cable: Plenum rated, Type CMP, two pair, No. 22 AWG, stranded copper; each pair 100 percent shielded, copper drain wire. C. RS-485 Cable: Plenum rated, Type CMP, two twisted pair, No. 22 AWG, stranded copper, unshielded. D. Coaxial cable for CATV, MATV and DBS: 1. RG-6: 16 AWG, solid, copper-covered steel conductor; gas-injected, foam-PE insulation. Double shielded with 100 percent aluminum-foil shield and 60 percent aluminum braid. Plenum rated, Type CMP. Use where the coaxial cable will be tapped or split. 2. RG-59 20 AWG, solid, copper-covered steel conductor; gas-injected, foam-PE insulation. Double shielded with 100 percent aluminum-foil shield and 40 percent aluminum braid. Plenum rated, Type CMP. Use for single device or from a tap or splitter. E. Control Circuits: 1. Low voltage control cable: twisted pairs #16 AWG with overall shield. 2. Class 1 Control Circuits: Stranded copper, Type THWN or XHHN, in raceway or cable with armor jacket. 3. Class 2 Control Circuits: Stranded copper, Type THWN or XHHN, in raceway, power-limited cable, concealed in building finishes, cable with armor jacket or power-limited tray cable, in cable tray and on hangers. 4. Class 3 Remote-Control and Signal Circuits: Stranded copper, Type TW or Type TF, complying with UL 83. 2.4 Grounding and Bonding A. Circuits, metal raceway systems, and all other permanently installed electrical equipment shall be solidly grounded in accordance with the California Electrical Code to form a continuous, permanent and effective grounding system. B. Grounding conductor connections shall be made with solderless pressure type fittings. Where welded connections are practical, connections may be made by the use of suitable welding process. All connections shall be made in strict conformance with the manufacturer's recommendations. C. To maintain uninterrupted electrical continuity, flexible raceway sections must have conductance equal to that of the system's inflexible raceway. Raceway fittings listed must be such as to ensure existence of a permanent bond. Grounding bushings shall be provided to ground conduits to control center ground. All new equipment shall be grounded to the existing grounding system. D. Include a separate bare ground conductor in all flexible metal cable of the same size as phase conductor. E. Isolated ground conductors: green colored insulation with continuous yellow stripe. F. Bonding interior metal ducts: bond metal air ducts to equipment grounding conductors of associated fans, blowers, electric heaters, and air cleaners. Install tinned bonding jumper to bond across flexible duct connections to achieve continuity. G. Ground rods to be 10'x3/4” copper clad steel. Ground rods at exterior area lights to be 8'x5/8” copper clad steel. 2.5 Conduit Hangers A. For individual conduit runs not directly fastened to the structure, use threaded rod and hangers manufactured by Caddy, Unistrut or Powerstrut. B. Galvanized steel slotted channel support systems with fittings and supports by the same manufacturer. 2.6 Raceways and Outlet Boxes A. Provide raceways, fittings, connectors and accessories for a complete raceway system. Raceways include: 1. Rigid steel: hot-dipped galvanized. 2. Intermediate metal conduit (IMC): hot-dipped galvanized. 3. Electrical metallic tubing (EMT): electro-galvanized. 4. Wireways: enamel finish, hinged type. 5. Flexible metallic conduit: for final connection in dry locations less than 6' lengths. 6. Liquid tight flexible metal conduit: for final connection in damp or wet locations less than 6' lengths. B. Provide fittings and accessories approved for the purpose equal in all respects to the conduit or raceway. EMT connectors and couplings shall be steel setscrew type indoors and steel compression type in damp or wet locations and outdoors. C. Outlet boxes: 4” square x 1-1/2” deep (or larger) galvanized sheet steel KO-type with plaster ring and cover for general interior use. Cast metal type FS or FD with matching screw covers for exterior and exposed interior locations (gasketed in damp or wet locations). D. Junction boxes shall be same as outlet boxes up to 42 cu. In. Use code-gauge steel in larger sizes with surface or flush-type screw-mounted trim covers. Boxes and covers painted with inhibitor-primed paint inside and out. E. Pull boxes shall be same as junction boxes unless indicated otherwise on the Drawings, with covers. F. Telephone outlet boxes shall be the type and size required by the serving telephone company but not smaller than 4-11/16” square x 2-1/2” deep with single-gang ring. Other configurations as shown on the plan. 2.7 Identification and Labeling A. Label all control devices and device enclosures with individual name plates or legend plates. B. Individual name or legend plates to be black laminated plastic plates with white cut letters. Paper, foil or tape markers attached with adhesives shall not be used. C. Engraved, laminated acrylic or melamine label, punched or drilled for screw mounting. White letters on a dark-gray background. Minimum letter height shall be 3/8 inch. D. Equipment to be labeled: 1. Panelboards, electrical cabinets, and enclosures. 2. Access doors and panels for concealed electrical items. 3. Electrical breakers in existing distribution panels. 4. Transformers. 5. Emergency system boxes and enclosures. 6. Disconnect switches. 7. Enclosed circuit breakers. 8. Motor starters. 9. Push-button stations. 10. Contactors. 11. Remote-controlled switches, dimmer modules, and control devices. 12. Panels, terminal cabinets, and racks. E. Accessible raceways and cables of auxiliary systems: Identify the following systems at panel and junction box locations within each room as follows: 1. Fire alarm system: Red boxes and covers. 2. 120/208 volt: Mark covers with panel and circuit numbers. 3. 277/480 volt: Mark covers with panel and circuit numbers. F. Receptacles: Identify panelboard and circuit number from which served. Use hot, stamped or engraved machine printing with black filled lettering on face of plate, and durable wire markers or tags inside outlet boxes. 2.8 Lighting Control Devices A. Time switches: Solid state programmable unit with multiple channels for exterior lighting control. B. Indoor occupancy sensor to be dual technology with solid state separate external relay unit for ceiling mounted units. C. Wall box occupancy sensors to have adaptive technology with time delay, quantity of integral switches as shown on the Drawings (minimum of one (1) switch). D. Lighting contactors: Mechanically held, non-fused switch with 2 wire solid state control modules. E. Emergency shunt relay: Normally closed electrically held with automatic switching contacts to bypass local room controls. F. Wall mounted programmable dimming control: installed where shown on the Drawings with scene selector and multi-station dimming over ride controls. Lutron Graphic Eye system. G. LED wall box dimmers: rated for quantity and type of fixtures shown on Drawings. Divide switch legs and add additional dimmers to meet manufacturer's recommendation. 2.9 Wiring Devices A. Wiring devices shall be installed in metal device boxes. B. Switches and receptacles shall be Lutron, Hubbell, Bryant, Leviton, Pass & Seymour, or approved equal subject to approval by the Architect, color shall be as noted on plans for normal power and red for emergency power. Special color device outlets and matching coverplate as noted on the plans. C. Switches shall be heavy duty grade, ac quiet type, 20-amp, 120/277-volt, with silver alloy contacts, equal to Hubbell #5362. D. General purpose duplex receptacles shall be heavy duty grade NEMA 5-20R, 20-amp, 125-volt, 3-wire grounding type devices with brass one piece ground strap; third pole grounding to the outlet box. E. Ground fault circuit interrupt (GFI) duplex receptacles shall be heavy duty grade, 20-amp devices wired so that each unit is self-contained. GFI receptacles shall not be connected to feed through unless specifically noted on the Drawings. F. Receptacles in damp or wet locations to have CEC Weather Resistant rating. G. Tamper Resistant rating in areas required by the CEC. H. AFCI outlets where required by the CEC. I. Isolated ground receptacles to be orange in color. J. Surge Protective Device (SPD) type 3 duplex receptacle with indication light and audible alarm. K. Special color plastic cover plates to match Style Line type receptacles as noted on the plans with matching colors. L. Weatherproof duplex receptacles shall be GFCI protected with “while-in-use” weatherproof coverplates. 2.10 Lighting Fixtures A. All fixtures to be LED, refer to light fixture schedule within drawing set for specifics. B. Dimming driver to be 0-10V compatible with the dimming controller selected. 2.11 Voice/Data Systems A. The Electrical Contractor is to install an empty conduit, backbox and junction box system for installation of the Owner's voice and data system by others. All telephone and network systems equipment and cabling shall be provided by the Owner's communications cabling contractor. 2.12 Miscellaneous Low Voltage Systems A. The Owner shall furnish and install the wire, cable, connecting devices, and provide testing for wiring systems to be used as signal pathways for low voltage system specified in this section where called for in the drawings. B. The Electrical Contractor is to install an empty conduit, backbox and junction box rough in for installation of the following Owner's systems: a. Security and Duress systems. PART 3 -EXECUTION 3.1 General A. Electric system layouts indicated on the Drawings are generally diagrammatic and shall be followed as closely as actual construction and work of other trades will permit. Govern exact routing of cable and wiring and the locations of outlets by the structure and equipment served. Take all dimensions from Architectural drawings. B. Consult all other drawings, verify scales and report any dimensional discrepancies or other conflicts with Owner before submitting bid. C. All home runs to panelboards are indicated as starting from the outlet nearest the panel and continuing in the general direction of that panel. Continue such circuits to the panel as through the routes were completely indicated. Terminate homeruns of signal, alarm and communication systems in a similar manner. D. Avoid cutting and boring holes through structure or structural members wherever possible. Obtain prior approval of Owner and conform to all structural requirements when cutting or boring the structure is necessary and permitted. E. Furnish and install all necessary hardware, hangers, blocking, brackets, bracing, runners, etc., required for equipment specified under this section. F. Provide necessary backing required to insure rigid mounting of outlet boxes. 3.2 Conductors and Cables A. Provide #12 branch circuit conductors for all 120V, 20 amp circuits less than 75' (100' for 277V circuits). Provide #10 branch circuit conductors for all 120V, 20 amp circuits over 75' (100' for 277V circuits). B. Where more than three current carrying conductors are installed in a single raceway (e.g. combining multi-circuit homeruns), conductor ampacity shall be de-rated as required by the CEC. C. Provide dedicated neutral circuits for all 120V and 277V branch circuits. D. Megger and record insulation resistance of all 600 volt insulated conductors size #4/0 and larger using 500 volt megger for one minute. Make tests with circuits isolated from source and load. 3.3 Low Voltage Conductors and Cables A. All low voltage cables installed in a metal box and raceway system to an accessible ceiling. B. Minimum conduit size is ¾” with larger sizes noted on plan. Install plastic bushing on conduit ends. C. Group and bundle low voltage cables and provide support independent of ceiling supports. Utilize D rings, J hooks or approved nylon straps to hold cables and provide supports independent of the ceiling supports. 3.4 Grounding and Bonding A. The building and electrical systems shall be grounded and bonded in accordance with the CEC, IEEE and best practices. B. Electrical service and separately derived alternating current systems shall be grounded in accordance with CEC, Article 250. C. All feeder and branch circuits shall have a green copper ground conductor run with the phase and neutral conductors. D. Provide Code required #6 or larger ground conductor and 12” ground bus at telecommunication demarcation location. 3.5 Raceways and Boxes A. Enclose all electrical power wiring in conduit. B. Conduit shall be rigid steel, IMC or EMT as follows: 1. Above ground: use rigid steel or IMC only. 2. Locations subject to mechanical injury. Rigid steel or IMC only. 3. Dry locations and not subject to mechanical injury: EMT, IMC or rigid steel conduit. C. Use flexible conduits in the following applications: 1. Recessed lighting fixtures. 2. Motor connections. 3. At building joints. 4. At wet locations, flexible conduit shall be liquid tight type. D. Metal clad cable with green ground conductor allowed only for the following conditions: 1. Above accessible ceilings for final connections from junction boxes to light fixtures not exceeding 6' in length. 2. Final connection not exceeding 6' in length to rotating or vibrating equipment. 3. Allowed for branch circuits fished into existing wall construction. 4. Allowed in new casework or built up structures where flexibility is required. E. Conduit cast in concrete floors are not allowed. F. Motor and transformer connections in dry locations shall be made with flexible metal conduit. Motor connections in damp or wet locations shall be made with liquid tight flexible metal conduit and appropriate fittings. G. All EMT fittings shall be steel compression type in exterior or damp locations. Fittings for other raceways shall be steel set-screw type style in interior dry locations. Die cast fitting are not allowed. H. Install nylon pull cords in all empty conduits. I. Provide expansion fittings crossing all expansion joints or spanning between isolated structures. J. Surface raceways to be a 2 compartment style similar to Wiremold G-4000 white finish with device outlets noted on plans. K. General conduit installation: 1. Run all conduit concealed unless otherwise noted or shown. 2. Run all conduit parallel to or at right angles to center lines of columns and beams. 3. Conduits above ceiling shall not obstruct removal of ceiling tiles, lighting fixtures, air diffusers, etc. 4. Conduits shall not cross any duct shaft or area designated as future duct shaft horizontally. Conduit riser, when allowed in duct shaft must be coordinated with mechanical work or avoid any conflict. L. Conduit supports: 1. Support conduits with Underwriter's Laboratories listed steel conduit supports at intervals required by the California Electric Code. Wires or sheet metal strips are not acceptable for conduit support. Use conduit hangers for all conduits not directly fastened to structure and for all multiple conduit runs. Do not attach any conduit to mechanical ducts or pipes. 2. Avoid attaching conduit to fan plenums. When it is necessary to support conduit from fan plenum, provide a length of flexible conduit between portions attached fan plenum and portion attached to the building to minimize transmission of vibration to the building structure. M. Conduit penetration: 1. Fire rated floor or wall: Install conduit in conduit sleeve or framed opening. Seal penetration with fire retardant sealant specified herein. 2. Roof or exterior wall: Avoid penetrating roof or exterior wall where possible. Where penetrations are necessary, building weatherproof integrity must be preserved. 3. Sound insulated or air plenum wall: Install conduit in conduit sleeve and seal penetration as detailed on the Drawings. 4. Non-fire rated dry wall: Conduit sleeves are not required. Penetrations must be sealed with plaster prior to painting. Penetrations made after wall finish is applied must be as small as possible and provided with escutcheons, one on each side of wall. 5. Suspended ceiling: Cut hole as small as possible to permit conduit penetration. Provide escutcheon for each conduit below ceiling. N. Outlet boxes: 1. Provide outlet boxes and pull boxes as required to accommodate lighting and receptacle branch circuit wiring. 2. Outlet boxes must not be installed back-to-back. 3. Outlet boxes used for wall box dimmers may not be ganged. Outlet boxes used for wall box dimmers must be de-rated when grouped under one cover. 4. Provide cast steel floor boxes to accommodate power and data connections to free standing equipment and furniture partitions. 5. All outlet boxes shall be two-gang or 4” square x 2” deep minimum with plaster ring sized as required. 6. Exterior boxes for branch circuits to be cast aluminum with threaded hubs. 3.6 Identification A. Provide nameplates for switchgears, panelboards, and all similar devices. Nameplates shall be screwed (no adhesive) engraved plastic or photo-etched metallic nameplate identification showing panel designation, voltage and phase in minimum ¼” high letters. B. Provide machine labels on all lighting switches and convenience and special purpose receptacles to show panel and circuit number to which the device is connected. C. Panelboard schedule: After completion of work, provide typewritten updated panelboard schedules for all panelboard in a metal framed circuit directory inside cover, with plastic protector. D. Color code wires as follows: 1. Voltage phase A phase, B phase, C, neutral ground. 2. 120/208V black, red, blue, white, green. 3. 277/480V brown, orange, yellow, gray, green. E. Provide Brady wire markers where number of conductors in a box exceeds four. 3.7 Lighting Control Devices A. Controllers: Furnish 120 volt power to each control panel and time switch requiring a source of power to operate. Drawings. A. Top of panelboard tubs shall be 6'-6” above finished floor. 3.8 Wiring Devices A. The Contractor shall furnish and install wall plates for all flush mounted wiring devices and all flush mounted special system outlets. Sectional wall plates shall not be used. Blank plates shall be installed over all outlets provided for future use. Wall plates shall be colored as noted on plans as manufactured by Lutron, Eagle, Bryant, General Electric, Hubbell or Leviton. Wall plates shall be secured with matching screws. Engraved wall plates shall have back fill. B. The Contractor shall furnish and install outlets for and make final electrical connections to all electrically powered equipment indicated on the plans or equipment schedules. 3.9 Lighting A. Lighting fixtures: Set level, plumb, and square with ceilings and walls complying with NFPA 70 for fixture supports. Install new lamps in each fixture. B. Suspended Lighting Fixture Support: 1. Pendants and Rods: Where longer than 48 inches, brace to limit swinging. 2. Stem-Mounted, Single-Unit Fixtures: Suspend with twin-stem hangers. 3. Continuous Rows: Use tubing or stem for wiring at one point and tubing or rod for suspension for each unit length of fixture chassis, including one at each end. Alternate: flexible cord connection for single circuit. C. Adjust and aim lighting fixtures to provide required light intensities on vertical surfaces or at directions noted on Drawings. Provide additional adjustments for Owner prior to final turnover or at substantial completion. D. Lighting fixtures mounted in continuous rows may be end fed with only the circuits feeding the row (passing trough of other circuits not allowed) with each row fed from individual junction boxes at the end feed point. E. Lighting fixtures must have individual feeds to each fixture. “Daisy-Chaining” of fixtures not allowed. The lighting fixture whips must be 6-feet long or less. 3.10 Voice/Data System A. Refer to Part 2 for additional information. B. For each telephone, data or telephone/data outlet indicated on the Drawings provide a 4” square box with single gang ring, and min. 1” conduit concealed from device to the nearest accessible ceiling, floor space or accessible access panel in hard ceilings, unless noted otherwise. Telecommunications installation on (HAS) property shall follow all (HAS) IT standards and Specifications. C. Install conduit bushings on conduit ends. Install pull cord in all conduits. D. The Owner shall furnish and install the wire, cable, connecting devices, and provide testing for wiring systems to be used as signal pathways for low voltage systems to be used as signal pathways for low voltage system specified in this section where called for in the Drawings. E. The Contractor shall coordinate the installation and schedule for all low voltage systems of this section with the Owner and adjacent affected tenants. The Contractor shall run all necessary conduits with pull wires, pull and junction boxes. F. Were low voltage systems pass through another tenant space or area not controlled by the Owner, the Contractor shall install complete conduit system in those spaces for the Owner's wiring. G. Provide 120v connections to equipment as required. Install 120v receptacle adjacent to all voice and data system outlets. 3.11 Miscellaneous Low Voltage Systems A. Refer to Part 2 for installation information. B. The Electrical Contractor shall coordinate the installation and installation schedule for all miscellaneous low voltage systems of this section with the Owner, landlord and affected tenants. C. The Electrical Contractor shall run all necessary conduits with pull wires, pull and junction boxes. D. Install conduit bushings on conduit ends. Install pull cord in all conduits. E. Provide 120v connections to equipment as required. Install 120v receptacle adjacent to all CCTV and A/V system outlets. END OF SECTION Engineering Consultants, LLC PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. 5137 Utica Ridge Road | Davenport, IA 52807 T: 563.726.6310 : www.rtmec.com Autodesk Docs://US Bank Corporate 2023/RTM-USB-CA-Arcadias-6354.rvt 11/13/2025 9:38:47 AM 14854C5247 JG AM 11/13/2025 E13453 11/13/2025 RANDALL MOSS 09/30/2026 ELECTRICAL SPECIFICATIONS E001 101 E Foothill Blvd, Arcadia, CA 91006 NO. DATE DESCRIPTION 11/13/2025 ISSUE FOR PERMIT A 100A MLO 120/208V 3P,4W MDP - 400A, 120/280V - 3Ø , 4W M 400A/3P X 100A/3P X EXISTING UTILITY TRANSFORMER J J J J J J J J J J J J J GENERAL NOTES 1. REFER TO SYMBOLS LEGEND AND GENERAL NOTES ON SHEET E000. 2. REFER TO ELECTRICAL SPECIFICATIONS ON SHEET E001. 3. ALL DEVICES ARE NEW UNLESS NOTED OTHERWISE. GENERAL ONELINE NOTES 1. PANEL SCHEDULE AND ONE-LINE ARE FILLED OUT FROM FIELD OBSERVATIONS AND ARE FOR REFERENCE ONLY. EC TO FIELD VERIFY EXISTING BUS RATING, MAIN CIRCUIT BREAKERS, AIC RATINGS, AND PANEL LOCATIONS. CONTRACTORS SHALL VERIFY EXISTING CONDITIONS AND UTILIZE CIRCUITS MADE SPARE BY DEMOLITION, SPARE CIRCUITS, AND AVAILABLE SPACE AS NECESSARY. X TO REST OF MDP EXISTING METER/CT X X 1 'A' 'MDP' X X X 'TEV' NOT IN SCOPE X NOT IN SCOPE NOT IN SCOPE X X X X X X X X X X X X X XX X X X X X X X X XXXXXXX X X XX X X X XX E101 3 BREAKROOM 114 MECH/NER 113 TELLER LINE 108 COUPON ROOM 109 ENTRY 101 ATM 103 LOBBY 102 ENTRY 105 WAITING 104 PLATFORMS 121 CONFERENCE 120 PLATFORMS 119 STORAGE 115 2D+48" +48" A:21 A:19 A:19 A:18 A:20 1 1 1 A:23 A:21A:23 111 2 2 2 X X 3 4 2D CKT:1 CKT:1 Engineering Consultants, LLC PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. 5137 Utica Ridge Road | Davenport, IA 52807 T: 563.726.6310 : www.rtmec.com Autodesk Docs://US Bank Corporate 2023/RTM-USB-CA-Arcadias-6354.rvt 12/17/2025 2:59:58 PM 14854C5247 JG AM 12/17/2025 E13453 12/17/2025 RANDALL MOSS 09/30/2026 ELECTRICAL POWER PLAN E101 101 E Foothill Blvd, Arcadia, CA 91006 #KEYNOTE 1 PROVIDE (1) JUNCTION BOX WITH 1" CONDUIT FOR DATA AND (1) JUNCTION BOX WITH 3/4" CONDUIT FOR POWER FROM THE FLOOR TO FEED THE FURNITURE. COORDINATE ALL CONNECTION REQUIREMENTS AND EXACT DEVICE QUANTITY WITH THE FURNITURE VENDOR. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. 2 EXISTING POWER AND DATA SERVING TELEVISION TO REMAIN. 3 RECEPTACLE TO BE TYPE L5-30 TWIST LOCK. 4 PROVIDE JUNCTION BOX AT BOTTOM OF WALL FOR CONNECTRAC CONNECTION FROM FLOOR. REFER TO ARCHITECTURAL DOCUMENTS FOR MORE INFORMATION. N SCALE: N.T.S.E101 2 EXISTING PARTIAL ONE LINE DIAGRAM 1/4" = 1'-0"E101 1 ELECTRICAL POWER PLAN 1/2" = 1'-0"E101 3 TYPICAL PLATFORM DESK Notes: Total Est. Demand:42 A Total Conn.:42 A Total Est. Demand:15160 VA Total Conn. Load:15160 VA Panel Totals A = ARC FAULT INTERRUPTER L = LOCK OUT S = SHUNT TRIP G = GROUND FAULT SENSING CKT = CIRCUIT E = EXISTING SPARE CIRCUIT BREAKER TO BE REUSED CB = CIRCUIT BREAKER N = PROVIDE CIRCUIT BREAKER, SIZE AS INDICATED MLO = MAIN LUGS ONLY CIRCUIT BREAKER INFORMATION LEGEND:ABBREVIATIONS: Total Amps:52 A 35 A 40 A Total Load:6220 VA 4220 VA 4720 VA E 41 EXISTING CIRCUIT -- 20 A 1 500 VA -- 1 -- -- SPACE 42 E 39 EXISTING CIRCUIT -- 20 A 1 500 VA -- 1 -- -- SPACE 40 E 37 EXISTING CIRCUIT -- 20 A 1 500 VA -- 1 -- -- SPACE 38 35 SPACE -- -- 1 -- -- 1 -- -- SPACE 36 33 SPACE -- -- 1 -- -- 1 -- -- SPACE 34 31 SPACE -- -- 1 -- -- 1 -- -- SPACE 32 29 SPACE -- -- 1 -- -- 1 -- -- SPACE 30 27 SPACE -- -- 1 -- -- 1 -- -- SPACE 28 25 SPACE -- -- 1 -- -- 1 -- -- SPACE 26 N 23 PLATFORM DESKS, PLATFORMS 121 6 A 20 A 1 720 VA -- 1 ---- SPACE 24 N 21 PLATFORM DESKS, PLATFORMS 119, 121 6 A 20 A 1 720 VA -- 1 -- -- SPACE 22 N 19 PLATFORM DESKS, PLATFORMS 119 6 A 20 A 1 720 VA 2000 VA 1 30 A 16.67 A ATM, ATM 103 20 N E 17 EXISTING CONVENIENCE OUTLET -- 20 A 1 500 VA 1000 VA 1 20 A 8.33 A PRINTER, PLATFORMS 119 18 N E 15 EXISTING LOUNGE AND BATHROOM -- 20 A 1 500 VA 500 VA 1 20 A -- EXISTING COMPUTER OUTLET LEFT 16 E E 13 EXISTING STORAGE AND LOBBY -- 20 A 1 500 VA 500 VA 1 20 A -- EXISTING STORAGE AND LOBBY 14 E E 11 EXISTING LOBBY LIGHTS -- 20 A 1 500 VA 500 VA 1 20 A -- EXISTING COPIER MACHINE 12 E E 9 EXISTING SIGN PHOTOCELL -- 20 A 1 500 VA 500 VA 1 20 A --EXISTING NIGHTLIGHT LOBBY 10 E E 7 EXISTING STORAGE ROOM -- 20 A 1 500 VA 500 VA 1 20 A -- EXISTING STORAGE ROOM 8 E E 5 EXISTING COMPUTER OUTLET -- 20 A 1 500 VA 500 VA 1 20 A -- EXISTING MANAGER FISHTANK 6 E E 3 EXISTING LOBBY LIGHTS -- 20 A 1 500 VA 500 VA 1 20 A -- EXISTING LOBBY LIGHTS 4 E E 1 EXISTING LOBBY LIGHTS -- 20 A 1 500 VA 500 VA 1 20 A -- EXISTING LOBBY LIGHTS 2 E CB Info CKT Circuit Description Amps Trip Poles A B C Poles Trip Amps Circuit Description CKT CB Info Enclosure:Type 1 Mounting:Surface Wires:4 Bus Amps:100 A Supply From:MDP Phases:3 Type:MLO Location:MECH/NER 113 Volts:120/208 Wye A.I.C. Rating:EXISTING Branch Panel: A NO. DATE DESCRIPTION 11/13/2025 ISSUE FOR PERMIT 1 12/17/2025 PLAN REVIEW COMMENTS J PP GENERAL NOTES 1. REFER TO SYMBOLS LEGEND AND GENERAL NOTES ON SHEET E000. 2. REFER TO ELECTRICAL SPECIFICATIONS ON SHEET E001. 3. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION OF EQUIPMENT OR OUTLETS. 4. THE EXISTING CONDITIONS SHOWN ARE FROM SITE SURVEY AND SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT SITE PRIOR TO SUBMITTING BID. ALL DEMOLITION, ALTERATION, EXTENSION, RELOCATION, REHABILITATION WORK SHALL BE INCLUDED IN CONTRACT. NO ADDITIONAL ALLOWANCE OR CHANCE ORDERS WILL BE ACCEPTED. 5. CONTRACTOR IS RESPONSIBLE TO RELOCATE OR REMOVE FROM WALLS, CEILINGS, FLOOR SPACES, ETC. ANY EXISTING CONDUITS, WIRES, BOXES, FITTINGS, FIXTURES OR OTHER ELECTRICAL EQUIPMENT WHICH INTERFERES WITH PLANNED REMODEL WORK. PROVIDE CIRCUIT CONTINUATION REQUIRED FOR ALL EXISTING OUTLETS, FIXTURES, EQUIPMENT, ETC. SCHEDULED TO REMAIN INSIDE AND OUTSIDE OF THE DEMOLITION SPACE AFFECTED BY THIS WORK. 6. NOTIFY THE ENGINEER IMMEDIATELY WHEREVER EXISTING EQUIPMENT IS ENCOUNTERED WHICH MUST BE RELOCATED DUE TO THE NEW CONSTRUCTION, OR NOT INDICATED ON "AS-BUILT" DRAWINGS OR WAS BURIED UNDERGROUND OR EMBEDDED IN STRUCTURE WALLS. 7. CAREFULLY PROTECT ALL WALLS, TRIM, FLOORS, EQUIPMENT, UTILITY LINES AND MATERIALS. WHEN WORKING ON FINISHED SURFACES, LIMIT DAMAGE TO THE SMALLER AREA IF POSSIBLE AND RESTORE TO THE ORIGINAL CONDITION ALL SURFACES WHICH ARE DAMAGED BECAUSE OF THE INSTALLATION OF THIS WORK. 8. EQUIPMENT, MATERIALS AND SUPPLIES TEMPORARILY REMOVED FOR PROTECTION SHALL BE REPLACED IN ORIGINAL LOCATIONS. ANY MATERIALS DAMAGED SHALL BE REPLACED WITH NEW MATERIALS OF LIKE KIND AND QUALITY. 9. DEMOLITION WORK SHALL BE DONE IN A MANNER WHICH WILL NOT CAUSE UNNECESSARY INCONVENIENCE OR DANGER TO USERS OF THE PREMISES AND ADJACENT SITE, AND NOT INTERFERE WITH ITS OPERATION. ANY DEMOTION WORK TO BE PERFORMED MUST BE PLANNED IN ADVANCE. 10. DO ALL DRILLING, CUTTING, ETC. REQUIRED TO DEMOLISH ELECTRICAL WORK AS INDICATED OR PROVIDE BLANK COVER PLATE ON ALL OUTLETS EXPOSED BY REMOVAL OF FIXTURE OF DEVICES. 11. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDUIT/WIRING RUNS, REUSE AS REQUIRE AND REMOVED ALL UNUSED CONDUIT/WRING. UNUSED CONDUIT IN INACCESSIBLE LOCATIONS (WALLS TO REMAIN) CAN BE ABANDONED IN PLACE, REMOVE UNUSED WRING. 12. CONTRACTOR TO VERIFY CIRCUIT NUMBER AND LOADS FOR ALL EXISTING EQUIPMENT PRIOR TO INSTALLATION OF NEW OR RELOCATED ELECTRICAL EQUIPMENT. REASSIGN CIRCUITS AND LOADS ACCORDINGLY. PROVIDE COMPLETE "AS BUILT DRAWINGS AND TYPEWRITTEN DIRECTORIES FOR PANELS. 13. WHERE NECESSARY TO SHUT OFF UTILITY SERVICES OR CAUSE INTERRUPTION TO POWER OR SIGNAL SYSTEMS WHILE A BUILDING IS OCCUPIED OR THAT EFFECT ADJACENT BUILDINGS, SCHEDULE OUTAGES OR INTERRUPTIONS WITH THE OWNER, BUILDING OCCUPANTS AND/OR ADJACENT BUILDING OWNERS) AND OCCUPANTS POOR TO CONDUCTING OUTAGE(S) OR INTERRUPTIONS. X X X XRPXO XO XO XO XO XRP X X X X X X X X X X X X X XX XO X X X X X X X X X XXXXXXX X X XX X X X 'MDP' 'A' 'TEV' NOT IN SCOPE NOT IN SCOPE NOT IN SCOPE X X 1 1 1 X X Engineering Consultants, LLC PROJECT FOR Project No. Drawn By Checked By Date ISSUES / REVISIONS CERTIFICATION 1220 Marshall St NE Minneapolis, MN 55413-1036 612.677.7100 rsparch.com RSP Architects Date Signed License No. Name Expiration Date NOTICE: The designs shown and described herein including all technical drawings, graphics, and models thereof, are proprietary and cannot be copied, duplicated or commercially exploited, in whole or in part, without express written permission of RSP Architects. These are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors and office personnel only in accordance with this Notice. © Copyright RSP Architects 2025. All rights reserved. ALL BIDDING QUESTIONS TO BE DIRECTED TO THE JLL PROJECT MANAGERS. SEE SHEET G000. 5137 Utica Ridge Road | Davenport, IA 52807 T: 563.726.6310 : www.rtmec.com Autodesk Docs://US Bank Corporate 2023/RTM-USB-CA-Arcadias-6354.rvt 11/13/2025 9:38:59 AM 14854C5247 JG AM 11/13/2025 E13453 11/13/2025 RANDALL MOSS 09/30/2026 ELECTRICAL DEMOLITION POWER PLAN ED101 101 E Foothill Blvd, Arcadia, CA 91006 #KEYNOTE 1 EXISTING POWER AND DATA SERVING TELEVISION TO REMAIN. N 1/4" = 1'-0"ED101 1 ELECTRICAL DEMOLITION POWER PLAN NO. DATE DESCRIPTION 11/13/2025 ISSUE FOR PERMIT