Loading...
HomeMy WebLinkAbout49 E Huntington Dr - 2026 -EXISTING PLANSCALE : 1/4" = 1'-0"2'-8"100'-0" (EXISTING)14'-11" (VERIFY)10'-10"9'-3"12'-4"11'-4"11'-6"8'-8"8'-0"100'-0"9'-0"9'-2"8'-6"9'-2"12'-6"2'-8"4INDICATES EXISTINGCONCRETE BLOCK WALLTO REMAIN24'-0" +/- (EXISTING)12"(R) RESTROOM118(E) ELECTRIC PANEL& METER7'-3"10'-6"(E) TRASHENCLOSURE11'-0"(R) BREAK RM.115(E) RESTROOM117(E) OFFICE101(E) OFFICE103(E) OFFICE104(E) OFFICE105(E) RECEPTION106(E) CONFERENCE107(E) COPY114112'-7"(E) OFFICE108(E) OFFICE109122"3'-0"SEE SHEET A93'-0"8'-4"4'-0"2'-0"3'-0"7'-8"(E) WORKSTATION112(E) WORKSTATION111(E) WORKSTATION102(E) DOORTO REMAIN23111148"50"42"UP1'-11"4'-6"22(E) STORAGE113(E) UTILITY1161(E) OFFICE1109'-0"4'-0"16'-8"6'-8"13'-1"PLATFORM GATE -PROVIDED BY LIFTMANUFACTURERCOMMERCIAL VERTICAL LIFT,36" X 48" W/ 90 ADJACENT ACCESS(36" VERTICAL TRAVEL) - MEETSASME A18.1, SECTION 2INSTALL PER MANUFACTURER'SSPECIFICATIONSLINE OF EXISTINGSKYLIGHT & SOFFITAMERIGLIDE "HERCULES II"o1'-9"1'-9"1'-9"8"4'-0"1'-10"2'-5"4'-1"2'-5"INDICATES EXISTINGCONCRETE BLOCK WALLTO REMAIN12"48"50"42"UP1'-11"4'-6"LINE OF EXISTINGSKYLIGHT & SOFFITPA OFFICEEXAM ROOM #4EXAM ROOM #3EXAM ROOM #2RECEPTION AREAMA WORK AREAWAITING ROOMTRIAGE ROOMEXAM ROOM #1PROCEDURE ROOMMD OFFICERESTROOMRESTROOMUTILITYSTORAGE ROOMDOOR TO REMAINELECTRIC PANEL & METERTRASH ENCLOSURELIFT TO REMAIN EXITEXITEXITBREAK ROOMMOP SINKPA OFFICEEXAM ROOM #4EXAM ROOM #3EXAM ROOM #2MA WORK AREARECEPTION AREAUTILITYSTORAGE ROOMMD OFFICEPROCEDURE ROOMEXAM ROOM #1TRIAGE ROOMWAITING ROOM33RESTROOMACCESSORY SCHEDULEMANUFACTURERMODEL NO.NOTEDESCRIPTION#123456789BOBRICKBOBRICKBOBRICKBOBRICKBOBRICKBOBRICKBOBRICKTOTOKOHLERB-5806 X 42B-5806 X 36B-290 1836B-822B-4262B-5221B-4288 MS604124CEFG#01K-2863111111111HORIZONTAL GRAB BAR ( 1 1/2" DIAMETER)HORIZONTAL GRAB BAR ( 1 1/2" DIAMETER)18" W X 36" H SURFACE MOUNTED MIRROR MOUNTED SOAP DISPENSER"CONTURA" SURFACE MOUNTED PAPER TOWEL DISPENSERSURFACE MOUNTED TOILET SEAT COVER DISPENSERSURFACE MOUNTED TOILET TISSUE DISPENSERULTRAMAX II ONE PIECE TOILETHUDSON WALL MOUNT LAVATORY SINK167882534D1/ #1INDICATES EXISTINGCONCRETE BLOCK WALLTO REMAIN12"EXISTING SINK &DISHWASHER50"42"UP1'-11"4'-6"LINE OF EXISTINGSKYLIGHT & SOFFITPA OFFICEEXAM ROOM #5EXAM ROOM #4RECEPTION AREAMA WORK AREAWAITING ROOMEXAM ROOM #3MD OFFICERESTROOMRESTROOMUTILITYSTORAGE ROOMDOOR TO REMAINELECTRIC PANEL & METERTRASH ENCLOSURELIFT TO REMAIN PPPBREAK ROOMPPROCEDURE ROOMEXAM ROOM #2EXAM ROOM #1TRIAGE ROOMD2/ #1D2/ #3D2/ #4WATER HEATERWHD2/ #2EXAM ROOM SIGNSRESTROOMSIGNAGE DETAILINTERIOR FINISH SCHEDULEMANUFACTURERMODEL NO.DESCRIPTIONMSI FLOORINGUSGARMSTRONGMSI FLOORINGVINYL FLOORING FOR HALLWAY & EXAM ROOMSGYPSUM PANELS FOR NEW WALLSLAY IN CEILING TILE (24" X 48")PORCELAIN TILE FOR FLOORING AND WALLVTRLINLOG9X48-8MM-22MILSINGLE LAYER 3/8 IN933NMALWHI2448L-3DD2/ #145°EXAM ROOM SIGNSEXAM ROOM SIGNSEXAM ROOM SIGNSEXAM ROOM SIGNSEXAM ROOM SIGNSCENTERED ON TACTILE CHARACTERS18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MIN18" MINEXITEXITEXITBREAK ROOMPA OFFICEEXAM ROOM #4EXAM ROOM #3EXAM ROOM #2MA WORK AREARECEPTION AREAUTILITYSTORAGE ROOMMD OFFICEPROCEDURE ROOMEXAM ROOM #1TRIAGE ROOMWAITING ROOM3345°ACCESSIBLE SEATING SPACE17"=25" MIN30" MIND3/#1, #2ALL ACCESSIBLESINK CLEARANCETOE AND KNEECLEARANCESEE SHEET A7D2/ #1UTILITYSTORAGE ROOMWORKSTATIONOFFICEOFFICEOFFICEWAITING ROOMWORKSTATIONOFFICEOFFICEOFFICEOFFICERECEPTION AREAWORKSTATIONEXAM ROOM SIGNSOFFICEBREAK ROOMRESTROOMRESTROOMTO BE REMOVEDTANKLESS WATER HEATER MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: TITLE SHEET A1 ANGELA TSAI MD OWNER: TENANT IMPROVEMENT FOR ARCADIA ENT ANGELA TSAI MD 49 E HUNTINGTON DRIVE ARCADIA, CA 91007 VICINITY MAP PROJECT DATA LIST OF CONSULTANTS INDEX OF DRAWINGS ASSESSOR'S PARCEL NUMBER: 5773-012-012 MEDICAL CLINIC: CLASS B BUILDING AREA LOT AREA: EXISTING TOTAL BUILDING: FLOOR AREA RATIO: 3,360 SQ. FT 2,340 SQ. FT 69.6% PARKING: ADA ACCESSIBLE SPACES PROVIDED: PUBLIC PARKING LOCATED BEHIND BUILDING 1 (ONE) OWNER: ANGELA TSAI 2111 S 2ND AVENUE ARCADIA, CA 91006 TENANT: ARCADIA ENT ANGELA TSAI MD 49 E HUNTINGTON DRIVE ARCADIA, CA 91007 DESIGN CONSULTANT: MILLION CONSTRUCTION & DEVELOPMENT 124 LAS TUNAS DRIVE ARCADIA, CA 91007 CONTACT: BENSON TSE TEL: 626-822-8200 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 D1 D2 D3 E1 E2 E3 E4 1 2 3 P1 P2 P3 P4 P5 P6 P7 PLB TITLE SHEET GENERAL NOTES SITE PLAN EXISTING FLOOR PLAN PROPOSED FLOOR PLAN REFLECTED CEILING PLAN E. HUNTINGTON BOULEVARD 2N D A V E 1S T A V E SA N T A A N I T A SITE WEST FOOTHILL EAST FOOTHILL W. DUARTE RD S. M Y R T L E S. M Y R T L E S. M Y R T L E E. DUARTE RD FOOTHILL FREEWAY 210 FREEWAY ACCESSIBLE RESTROOM PLAN CONSTRUCTION TYPE: TYPE IIIB ENGINEERING GENERAL NOTES ELECTRIC PANEL CALCULATIONS POWER PLAN LIGHTING FIXTURE SCHEDULE NON RESIDENTIAL T24 SHEET NON RESIDENTIAL T24 SHEET NON RESIDENTIAL T24 SHEET PLUMBING PLAN PLUMBING PLAN HOT & COLD WATER PLAN WASTE & VENT HOT & COLD ISOMETRIC DIAGRAM HOT & COLD ISOMETRIC DIAGRAM DOMESTIC WATER HEATING SYSTEM ENGINEER: PERFECT DESIGN & MANAGEMENT INC 2416 W. VALLEY BLVD. ALHAMBRA, CA 91803 CONTACT: RAYMOND MENG ZHONG TEL: 626-289-8808 NOTE: FIRE ALARM PLAN TO BE DEFERRED NOTE: FIRE SPRINKLER SUBMITTAL TO BE DEFERRED DETAIL SHEET SUMMARY OF ACCESSIBILITY OF IMPROVEMENTS & INTERIOR FINISH SCHEDULE DETAIL SHEET EXISTING ELEVATION & AERIAL PHOTOS EXISTING REFLECTED CEILING PLAN DETAIL SHEET GAS MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: GENERAL NOTES ANGELA TSAI MD OWNER: GENERAL NOTES 1.THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS TO INCLUDE ALL LABOR, MATERIALS, AND SERVICES NECESSARY FOR COMPLETION OF ALL WORK SHOWN, PRESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED IN THE CONTRACT DOCUMENTS. 2.ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES, ORDINANCES, AND REGULATIONS AS ADOPTED BY LOCAL AUTHORITIES HAVING JURISDICTION. 3.DIMENSIONS ON DRAWINGS ARE SHOWN TO CENTERLINE OF COLUMNS AND FACE OF STUDS, UNLESS INDICATED OTHERWISE ON DRAWINGS. 4.DO NOT SCALE THE DRAWINGS. 5.NO MECHANICAL OR ELECTRICAL WORK UPGRADES 6.DIMENSIONS, DETAILS, NOTES, AND/OR SYMBOLS THAT APPLY TO ONE UNIT, APPLY TO ALL UNITS IN LIKE SITUATION, UNLESS NOTED OTHERWISE. 7.DETAILS NOTED AS "TYPICAL" SHALL APPLY IN ALL LIKE CONDITIONS UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR LIKE CASES OF CONSTRUCTION OF THIS PROJECT. 8.THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONTIONS ON THE JOB-SITE PRIOR TO BEGINNING CONSTRUCTION AND SHALL REPORT ANY DISCREPANCIES OR UNIDENTIFIED CONDITIONS TO THE ARCHITECT FOR RESOLUTION BEFORE ANY WORK IS BEGUN. 9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS, METHODS, TECHNIQUES, AND PROCEDURES EMPLOYED IN THE PERFORMANCE OF WORK IN, OR ON, OR ABOUT THE JOB-SITE, THE CONTRACTOR SHALL COORDINATE AND VERIFY ALL WORK PERFORMED BY SUB-CONTRACTORS. 10.ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK ON, OR RELATED TO THIS PROJECT SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE PLACE TO WORK AND THE PUBLIC PROTECTED, AND SHALL COMPLY WITH THE OCCUPATIONAL SAFETY AND HEATH REGULATION OF THE U.S DEPARTMENT OF LABOR AND REGULATIONS. THE CONTRACTOR AGREES TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB-SITE SAFETY CONDITIONS DURING THE COURSE OF CONSTRUCTION OF TH E PROJECT; THAT THIS REQUIREMENT SHALL APPLY CONTINUALLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD HARMLESS THE OWNER AND DESIGN CONSULTANT FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. 11.THE STRUCTURE IS DESIGNED AS A STABLE UNIT AFTER ALL COMPONENTS ARE IN PLACE. THE CONTRACTOR SHALL DESIGN AND PROVIDE SHORING AND BRACING NECESSARY TO ENSURE THE STABILITY OF ANY AND ALL PARTS OF THE BUILDING DURING CONSTRUCTION. 12.REFER TO THE CIVIL ENGINEER'S DRAWINGS FOR LOCATIONS OF EXISTING UTILITY LINES, LOCATIONS OF ALL UTILITIES SHOWN ARE APPROXIMATE AND THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN EXCAVATION AND TRENCHING TO AVOID INTERCEPTING EXISTING PIPING OR CONDUITS. 13.CONTRACTOR SHALL FOLLOW ALL RECOMMENDATIONS OF THE APPROVED SOILS REPORT. 14.LOCATIONS OF ALL UTILITIES SHOWN ON THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE LOCATION OF AL SITE UTILITIES AND TO COORDINATE AND AVOID CONFLICT IN THE LOCATION SO F NEW UNDERGROUND AND SITE UTILITIES. THE CONTRACTOR SHALL ALL NECESSARY UTILITY FEES, METERS, AND CONNECTIONS IN HIS BID. 15.THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND DESIGN CONSULTANT SHOULD UNIDENTIFIED FIELD CONDITIONS BE DISCOVERED. 16.THE CONTRACTOR SHALL KEEP AN UP-TO-DATE RECORD OF "AS BUILT" CONDITIONS OF THE WORK, THE "AS-BUILT" SET SHALL BE RETURNED TO THE DESIGN CONSULTANT. THE SET SHALL INDICATE COMPLETELY ALL ADDITIONS, DELETIONS, CORRECTIONS, AND REVISIONS IN THE ACTUAL CONSTRUCTION OF THE PROJECT. 17.ALL GYPSUM BOARD USED AS TILE BACKING IN TOILET ROOMS SHALL BE WATER RESISTANT. 18.ALL ROOFING MATERIALS SHALL COMPLY WITH ALL APPLICABLE STANDARDS LISTED IN THE CBC. 19.REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 20.REQUIRED EXIT DOORS MUST OPEN OVER A LANDING NOT MORE THAN 12" BELOW THE THRESHOLD AND THE DOOR SHALL SWING IN THE DIRECTION OF EXIT TRAVEL. 21.REQUIRED EXIT DOORS SHALL NOT BE LESS THAN 3'-0" IN WIDTH AND 6-8" IN HEIGHT AND NO SINGLE LEAF SHALL EXCEED 4'-0" IN WIDTH. 22.THE FLOOR ADJACENT TO ANY DOORWAY SHALL BE LEVEL (14" PER FOOT MAX. SLOPE FOR EXTERIOR CONDITIONS) FOR A DISTANCE OF FIVE FEET FROM THE DOOR IN THE DIRECTION OF THE DOOR SWING AND SHALL NOT BE LESS THAN FIVE FEET WIDE. 23.ILLUMINATED EXIT SIGNS SHALL BE PROVIDED AT EXIT DOORS AND IN OTHER LOCATIONS, AS SHOWN ON PLANS, WHERE REQUIRED BY, IN ACCORDANCE WITH, APPLICABLE LAWS. THE PRINCIPLE STROKE OF SUCH SIGNS SHALL BE NOT LESS THAN 3 4" WIDE AND 6" TALL. ENERGY NOTES 1.ALL EXTERIOR DOORS AND DOORS TO UN-CONDITIONED SPACES SHALL BE FITTED WITH A SEAL AT THE HEAD, JAMB, AND SILL. 2.DOOR JAMBS ON AN EXTERIOR WALL SHALL LAP THE ADJACENT WALL A MINIMUM OF ONE INCH ON BOTH THE INTERIOR AND EXTERIOR SIDE. 3.DOORS MOUNTED BETWEEN JAMBS SHALL HAVE A CONTINUOUS SEAL AT EACH JAMB. 4.SWINGING DOORS SHALL BE WEATHER-STRIPPED AT THE HEAD, SILL, AND JAMB. 5.OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS AND FLOORS, AND ALL OTHER OPENINGS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SHALL BE SEALED, CAULKED, GASKETED, OR WEATHER-STRIPPED TO LIMIT AIR INFILTRATION. FIRE SAFETY NOTES 1.THE CONTRACTOR SHALL PROVIDE FIRE PROTECTION FOR THE PROJECT UNDER CONSTRUCTION PER THE REQUIREMENTS OF THE LOCAL GOVERNING AGENCIES. THE CONTRACTOR SHALL PROVIDE AND INSTALL AUTOMATIC FIRE SPRINKLER SYSTEM AND ALARM SYSTEM INCLUDING ALL ON-SITE FIRE HYDRANTS AND UNDERGROUND MAINS PER REQUIREMENTS OF LOCAL, GOVERNING AGENCIES AND ANY IDENTIFIED OWNER INSURING AGENCIES. SPRINKLER SYSTEM PLANS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. CONTRACTOR SHALL BE RESPONSIBLE FOR APPLICABLE PLAN CHECKS AND SHALL BE RESUBMITTED TO THE BUILDING DEPARTMENT AND DESIGN CONSULTANT.WHERE ENUNCIATOR PANELS, ALARMS, ETC. ARE REQUIRED IN AN EXPOSED SPECIFICATION SHEETS INDICATING FINISHES AN SIZES TO THE DESIGN CONSULTANT FOR APPROVAL PRIOR TO INSTALLATION. 2.THE CONTRACTOR SHALL PROVIDE AND INSTALL FIRE DAMPERS WHERE DUCTS PENETRATE FIRE RATED ASSEMBLIES. 3.WHERE NONCOMBUSTIBLE CONDUIT OR PIPE PENETRATES FIRE RATED ASSEMBLIES, THE CONTRACTOR SHALL INSTALL APPROVED FIRE RATED MATERIAL TO MAINTAIN INTEGRITY OF THE ASSEMBLY. 4.RETURN AIR PLENUMS SHALL HAVE NO EXPOSED MATERIALS WITHIN THEM WITH A FLAME SPREAD RATING OF 26 OR GREATER OR A SMOKE DEVELOPED RATING OF 50 OR GREATER. ALL WIRING IN RETURN AIR PLENUMS SHALL BE IN NON COMBUSTIBLE CONDUIT OR SHALL HAVE APPROVED PLENUM RATING. TEMPERATURES IN RETURN AIR PLENUMS SHALL BE RESTRICTED TO A RANGE OF 50 TO 125 DEGREES FAHRENHEIT AND MOISTURE CONTENT SHALL BE CONTROLLED SO AS TO NOT ADVERSELY AFFECT GYPSUM PRODUCTS WITHIN THE PLENUM. 5.ALL EXPOSED COMBUSTIBLE FRAMING MEMBERS WITHIN A RETURN AIR PLENUM SHALL BE SHEATHED WITH MIN., ONE LAYER OF 1 2" GYPSUM BOARD SECURELY FASTENED AND TAPED (PROVIDE BLOCKING / FURRING AS REQUIRED UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. FIRE RETARDENT WOOD AND HEAVY TIMBER MEMBERS MAY BE EXPOSED IN THE RETURN AIR PLENUMS WHEN SPECIFICALLY APPROVED BY THE BUILDING OFFICIAL). 6.CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS OF TYPE, QUANTITY AND LOCATION AS DETERMINED BY THE FIRE DEPARTMENT INSPECTOR. 7.PROVIDE AND INSTALL OUTSIDE GAS SHUTOFF VALVE AND SIGNAGE IDENTIFYING LOCATIONS OF GAS AND ELECTRICAL SHUTOFFS PER THE FIRE DEPARTMENT INSPECTOR. (WHERE APPLICABLE) 8.PROVIDE AND INSTALL SMOKE DETECTORS, DUCT DETECTORS, AND OTHER SUCH DETENTION DEVICES AS REQUIRED BY THE FIRE DEPARTMENT INSPECTOR. 9.PROVIDE SIGNAGE, ROOF ADDRESS, BUILDING ADDRESS, ETC. AS REQUIRED BY THE FIRE DEPARTMENT INSPECTOR. 10.PROVIDE MASTER KEY KNOX BOX AT ENTRY OF THE BUILDING AS REQUIRED BY THE FIRE DEPARTMENT INSPECTOR. LOCATIONS SHALL BE APPROVED BY THE DESIGN CONSULTANT PRIOR TO INSTALLATION. HANDICAPPED ACCESS NOTES 1.THE BOTTOM 10" OF ALL DOOR SHALL HAVE A SMOOTH, UNINTERRUPTED PANEL FOR OPENING BY WHEELCHAIR FOOTREST. 2.CENTER OF ALL DOOR HARDWARE TO BE 33" TO 44" ABOVE FLOOR, LATCHING AND LOCKING DOORS TO BE OPERABLE WITH A SINGLE EFFORT BY LEVER OR PUSH/PULL TYPE HARDWARE. 3.THE MAXIMUM EFFORT REQUIRED TO OPERATE A DOOR SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS WITH A PULL OR PUSH EFFORT BEING APPLIED AT A RIGHT ANGLE AT HINGED DOORS. WHEN FIRE RATED DOORS ARE UTILIZED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO 15 LBS WITH A CLOSURE DEVICE. 4.FAUCET CONTROLS AND OPERATING MECHANISMS FOR DRINKING FOUNTAINS, KITCHEN SINKS, LAVATORIES, AND TOILET FIXTURES SHALL BE OPERABLE WITH ONE HAND NOT REQUIRING GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO OPERATE CONTROLS SHALL NOT EXCEED FIVE POUNDS. THE FLUSH ACTIVATOR ON ALL TOILETS SHALL BE LOCATED AT THE WIDE SIDE SIDE OF THE TOILET COMPARTMENT. MAXIMUM HEIGHT OF FLUSH VALVES FOR ACCESSIBLE FIXTURES SHALL NOT EXCEED 44" A.F.F. 5.THE MAXIMUM SLOPE OF ANY HANDICAPPED ACCESSIBLE PARKING STALL SHALL NOT EXCEED 2% IN ANY DIRECTION. 6.LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH/PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. 7.ALL FLOOR SURFACES IN THE ACCESSIBLE PATH OF TRAVEL SHALL BE SLIP RESISTANT. 8.AFFIX AN INTERNATIONAL ACCESSIBILITY SYMBOL ON ALL ACCESSIBLE ENTRANCES (1117B.5.1) 9.LANDINGS OR FLOOR LEVEL AT DOORS SHALL NOT BE LESS THAN 12" BELOW THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 1 4" AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE VERTICAL UNIT IN TWO HORIZONTAL UNITS (CBC 1008.1.7) MECHANICAL/ELECTRICAL NOTES 1.NO MECHANICAL OR ELECTRICAL UPGRADES, KEEP AS EXISTING. A2 D2/ #1 EXISTING ADJACENT BUILDING EXISTING ADJACENT BUILDING EXISTING 2,340 S.F SINGLE-STORY BUILDING TO BE REMODELED TRASH ENCLOSURE NO P A R K I N G PR O P E R T Y L I N E PA R K I N G WI D T H PARKING LENGTH 140'-10" 100" 6'-10" 20' 9' 8' 24 ' PROPERTY LINE (EXISTING BUILDING)40' 33'-7" HU N T I N G T O N D R I V E ELECTRICAL METER & PANEL SITE PLAN SCALE : 1/8" = 1'-0" MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: SITE PLAN SCALE 18"" = 1' -0" ANGELA TSAI MD OWNER: 6" X 6" X 4' LONG CONCRETE WHEEL 4" WIDE, BLUE STRIPING @36" O.C PUBLIC PARKING LOT EN T R A N C E EXISTING BUILDING A3 WALKWAY TO HUNTINGTON DRIVE (FRONT STREET) MAX SLOPE OF 2% INSPECTOR TO VERIFY MAX 2% SLOPE NOTE: INSPECTOR TO VERIFY PARKING ALLEY WALKWAY TO FRONT ENTRY PUBLIC PARKING 4' 1' 4' 1' REQUIRED CLEAR FLOOR SPACE REQUIRED CLEAR FLOOR SPACE TRUNCATED DOMES SEE D2/#5 MAX SLOPE OF 5% , INSPECTOR TO VERIFY NEW CONCRETE CURB RAMP GAS METER INDICATES EXISTING CONCRETE BLOCK WALL TO REMAIN 12" 48" 50 " 42 " UP 1'-11"4'-6" LINE OF EXISTING SKYLIGHT & SOFFIT PA OFFICE EXAM ROOM #4 EXAM ROOM #3 EXAM ROOM #2 RECEPTION AREA MA WORK AREA WAITING ROOM TRIAGE ROOM EXAM ROOM #1 PROCEDURE ROOM MD OFFICE RESTROOM RESTROOM UTILITY STORAGE ROOM DOOR TO REMAIN ELECTRIC PANEL & METER TRASH ENCLOSURE LIFT TO REMAIN EX I T EX I T EX I T BREAK ROOM MOP SINK D1/ #1 D2/ #1 D2/ #3 D2/ #4 WATER HEATER WH D2/ #2 EXAM ROOM SIGNS RESTROOMSIGNAGE DETAIL 45° EXAM ROOM SIGNS EXAM ROOM SIGNS EXAM ROOM SIGNS EXAM ROOM SIGNS EXAM ROOM SIGNS CENTERED ON TACTILE CHARACTERS 18" M I N 18" MIN 18" M I N 18" MIN 18" M I N 18" MIN 18 " M I N 18" MIN 18" MIN 18" M I N 18" MIN 18" M I N 18" MIN 18" MIN 18" M I N 18" M I N ACCESSIBLE SEATING SPACE 17" = 2 5 " M I N 30" MIN D3/#1, #2 ALL ACCESSIBLESINK CLEARANCETOE AND KNEECLEARANCE SEE SHEET A7 D2/ #1 EXAM ROOM SIGNS TO BE REMOVED TANKLESS WATER HEATER MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: PROPOSED FLOOR PLAN SCALE 1 4" = 1' -0" ANGELA TSAI MD OWNER: ARCADIA ENT, ANGELA TSAI MD TENANT IMPROVEMENT 6'-8"14'10'-4"16'-4" 25'-6"12'-4"12'-9"10'-4"9'-10"16'10'-6" 16'-8" 4' 9' 11 ' 24 ' 100' 3' EX I S T I N G 10'-10"11'-4"11'-2" A4 PROPOSED FLOOR PLAN IMPROVEMENTS SCALE : 1/4" = 1'-0" FLOOR PLAN LEGEND INDICATES EXISTING STUD WALL TO REMAIN INDICATES EXISTING C.M.U. BLOCK WALL TO REMAIN INDICATES NEW 3 5/8" METAL STUD WALL - EXTEND TO ROOF FRAMING AND PROVIDE R-13 INSULATION FOR SOUND-PROOFING SEE DETAIL 1 / D1 5 ' 4' 5' - 8 " 5' - 8 " 36" MINIMUM 8' 9' - 4 " 7' - 6 " 5 ' 1' - 6 " 1'-6" 4' 3' EXISTING PLAN SCALE : 1/4" = 1'-0" 2'-8" 100'-0" (EXISTING) 14'-11" (VERIFY)10'-10"9'-3"12'-4"11'-4"11'-6"8'-8"8'-0" 100'-0" 9'-0"9'-2"8'-6"9'-2"12'-6"2'-8" 4 INDICATES EXISTING CONCRETE BLOCK WALL TO REMAIN 24 ' - 0 " + / - ( E X I S T I N G ) 12" (R) RESTROOM 118 (E) ELECTRIC PANEL & METER 7'-3"10'-6" (E) TRASH ENCLOSURE 11 ' - 0 " (R) BREAK RM. 115 (E) RESTROOM 117 (E) OFFICE 101 (E) OFFICE 103 (E) OFFICE 104 (E) OFFICE 105 (E) RECEPTION 106 (E) CONFERENCE 107 (E) COPY 114 1 12'-7" (E) OFFICE 108 (E) OFFICE 109 1 22" 3'-0" SEE SHEET A9 3'-0" 8' - 4 " 4'- 0 " 2'- 0 " 3'-0" 7' - 8 " (E) WORKSTATION 112 (E) WORKSTATION 111 (E) WORKSTATION 102 (E) DOOR TO REMAIN 2 3 1 1 1 1 48" 50 " 42 " UP 1'-11"4'-6" 2 2 (E) STORAGE 113 (E) UTILITY 116 1 (E) OFFICE 110 9' - 0 " 4' - 0 " 16'-8"6'-8"13'-1" PLATFORM GATE - PROVIDED BY LIFT MANUFACTURER COMMERCIAL VERTICAL LIFT, 36" X 48" W/ 90 ADJACENT ACCESS (36" VERTICAL TRAVEL) - MEETS ASME A18.1, SECTION 2 INSTALL PER MANUFACTURER'S SPECIFICATIONS LINE OF EXISTING SKYLIGHT & SOFFIT AMERIGLIDE "HERCULES II" o 1'-9"1'-9" 1' - 9 " 8" 4'- 0 " 1'-10" 2'-5"4'-1"2'-5" MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: EXISTING PLAN SCALE 1 4" = 1' -0" ANGELA TSAI MD OWNER: A5 FLOOR PLAN LEGEND INDICATES WALLS TO BE DEMOLISHED UTILITY STORAGE ROOM WORKSTATION OFFICE OFFICE OFFICE WAITING ROOMWORKSTATION OFFICE OFFICE OFFICE OFFICE RECEPTION AREAWORKSTATIONOFFICEBREAK ROOMRESTROOM MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: EXISTED REFLECTED CEILING PLAN SCALE 1 4" = 1' -0" ANGELA TSAI MD OWNER: A6 EXISTING RCP SCALE : 1/4" = 1'-0" LIGHTING LEGEND 2' x 4' LED RECESSED PANELS ILLUMINATED EXIT SIGN 6" DIAMETER LED RECESSED DOWNLIGHTS EXIT 2' x 2' LED RECESSED PANELS SUPPLY AIR REGISTER RETURN AIR GRILLE EX I T EX I T EX I T BREAK ROOM PA OFFICE EXAM ROOM #4 EXAM ROOM #3 EXAM ROOM #2 MA WORK AREA RECEPTION AREA UTILITY STORAGE ROOM MD OFFICE PROCEDURE ROOM EXAM ROOM #1 TRIAGE ROOM WAITING ROOM 3 3 45° RESTROOM MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: REFLECTED CEILING PLAN SCALE 1 4" = 1' -0" ANGELA TSAI MD OWNER: A7 REFLECTED CEILING PLAN SCALE : 1/4" = 1'-0" LIGHTING LEGEND 2' x 4' LED RECESSED PANELS ILLUMINATED EXIT SIGN 6" DIAMETER LED RECESSED DOWNLIGHTS EXIT 2' x 2' LED RECESSED PANELS SUPPLY AIR REGISTER RETURN AIR GRILLE NOTES 1.ALL AC REGISTER AND RETURN AIR GRILLE TO REMAIN AS THE SAME 1 6 7 8 8 2 5 3 4 RESTROOM ACCESSORY SCHEDULE MANUFACTURER MODEL NO.NOTE DESCRIPTION# 1 2 3 4 5 6 7 8 9 BOBRICK BOBRICK BOBRICK BOBRICK BOBRICK BOBRICK BOBRICK TOTO KOHLER B-5806 X 42 B-5806 X 36 B-290 1836 B-822 B-4262 B-5221 B-4288 MS604124CEFG#01 K-2863 1 1 1 1 1 1 1 1 1 HORIZONTAL GRAB BAR ( 1 1/2" DIAMETER) HORIZONTAL GRAB BAR ( 1 1/2" DIAMETER) 18" W X 36" H SURFACE MOUNTED MIRROR MOUNTED SOAP DISPENSER "CONTURA" SURFACE MOUNTED PAPER TOWEL DISPENSER SURFACE MOUNTED TOILET SEAT COVER DISPENSER SURFACE MOUNTED TOILET TISSUE DISPENSER ULTRAMAX II ONE PIECE TOILET HUDSON WALL MOUNT LAVATORY SINK MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: ACCESSIBLE RESTROOM PLAN ANGELA TSAI MD OWNER: A8 THE COMBINED CIRCLE AND TRIANGLE CONSISTS OF A CIRCLE SYMBOL 1/4" THICK THICK & 12" IN DIAMETER WITH AN EQUILATERAL TRIANGLE. THE VERTICES OF THE TRIANGLE SYMBOL SHALL BE LOCATED 1/4" MAXIMUM FROM THE EDGE OF THE CIRCLE SYMBOL WITH A VERTEX POINTING UPWARD. THIS RESTROOM SIGNAGE SHALL BE LOCATED ALONGSIDE THE THE DOOR AT THE LATCH SIDE SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18" MINIMUM BY 18" MINIMUM, CENTERED ON THE TACTILE CHARACTERS PROVIDED. SIGNAGE WILL BE MOUNTED ON THE WALL WITH 48" MINIMUM HEIGHT OF BOTTOM OF THE RAISED CHARACTERS. THE SIGNS SHALL BE IN A COLOR THAT IS A DISTINCT CONTRAST FROM THE COLOR OF THE DOOR. PROVIDE SOLID BLOCKING @ GRAB BAR CONNECTION (TYPICAL) NON- ABSORBANT WALL FINISH 1 1/4" TO 1 1/2" NOMINAL DIAMETER WATER RESISTANT GYPSUM BOARD GRAB BAR SHALL BE INSTALLED TO RESIST 250 LBS. MIN. LATERAL LOAD TO FINISH FLOOR 4' - 7 " NOTE: ALL ACCESSORIES SPECIFIED IN THIS TABLE ARE RECOMMENDED FOR COMPLIANCE WITH HANDICAPPED ACCESSIBILITY LAWS, SUBSTITUTIONS MAY BE MADE WITH ACCESSORIES OF "EQUAL" SPECIFICATIONS. ELEVATION VIEWS PLAN VIEWS SCALE: 1/2" = 1' - 0"SCALE: 1/2" = 1' - 0" RESTROOM SIGNAGE SCALE: 1/2" = 1' - 0"GRAB BAR DETAIL ACCESSORY SCHEDULESCALE: 3/4" = 1' - 0" 5 ' 1' - 6 " 1' - 5 " 2' - 5 " 1' - 5 " 1' - 7 " 9'-6" 7' - 1 0 " 9" 48 " M I N WHITE BLUE 42" MIN 36" MIN 54" MIN 33 " - 3 6 " A F F 33 " - 3 6 " A F F 12" MAX PIPES UNDER SINK SHALL BE INSULATED TO PREVENT BURNS ALL GENDER MULTI-USER 60 " M A X INTERIOR FINISH SCHEDULE MANUFACTURER MODEL NO.DESCRIPTION MSI FLOORING USG ARMSTRONG MSI FLOORING VINYL FLOORING FOR HALLWAY & EXAM ROOMS GYPSUM PANELS FOR NEW WALLS LAY IN CEILING TILE (24" X 48") PORCELAIN TILE FOR FLOORING AND WALL VTRLINLOG9X48-8MM-22MIL SINGLE LAYER 3/8 IN 933 NMALWHI2448L-3D MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: SUMMARY OF ACCESSIBILITY IMPROVEMENTS AND INTERIOR SCHEDULE ANGELA TSAI MD OWNER: A9 MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: EXISTING ELEVATION & AERIAL PICTURES ANGELA TSAI MD OWNER: A10 BACK ELEVATION FRONT ELEVATION ROOF VIEW SITE VIEW 1 SITE VIEW 2 EXISTING ELEVATION & AERIAL PHOTOS MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: DETAIL SHEET ANGELA TSAI MD OWNER: D1 CONCRETE SLAB FLOOR CONTINUOUS 3 58" X 25 GA. UNPUNCHED TRACK W/ POWDER ACTUATED ANCHOR @ 32" O.C. AND 6" FROM EACH END (HILTI - ICBO #2388) 58" TYPE 'X' GYP BD @ EACH SIDE PROVIDE R-19 INSULATION FOR SOUND-PROOFING 3 5 8" X 25 GA. METAL STUD @ 16" O.C. (ICC-ES ESR 2620) SUSPENDED CEILING LINE SEE PLAN WHERE OCCURS CONTINUOUS 25 GA. RELIEF CHANNEL ROOF OR FLOOR FRAMING ABOVE PROVIDE #8 SCREWS @ 24" O.C. AND 6" FROM EACH END ATTACHMENT TO WOOD FRAMING PROVIDE BLOCKING AS REQUIRED EXISTING ROOF FRAMING 2 X BLOCKS W/ A ON EACH SIDE & EACH END 3 5 8" STEEL STUD DIAGONAL BRACE (2) #8 SELF-TAPPING SCREWS EXISTING ROOF FRAMING 3 58" STEEL STUD DIAGONAL BRACE (2) #8 SELF-TAPPING SCREWS MAIN RUNNER WALL ANGLE CROSS TEE HANGER OPTIONAL BOX FIXTURE LIGHT FIXTURE DUCT & NON - MODULAR DIFFUSER SECONDARY SUPPORT FIELD CUT TILEMAIN RUNNER OPTIONAL HOLDOWN CLIPS HANGER ·LAY-IN PANELS SHOULD BE SECURED IN PLACE BY CLIPS WHEN ASSEMBLY REQUIRES A FIRE RESISTANCE RATING, ALSO AGAINST UPLIFT DUE TO PRESSURE DIFFERENTIAL. ·IF A FIRE RATED CEILING IS SPECIFIED, FIXTURES, GENERALLY HAVE TO BE BOXED-IN FOR FIRE RESISTANCE RATING; FIRE DAMPERS MUST BE PROVIDED AT ALL OPENINGS SUCH AS DIFFUSERS. ·HANGERS SECURED TO FRAMING MEMBERS, STRUCTURAL DECK, OR TO SECONDARY FRAMING SYSTEM. 3 5 8" X 58" (20) GA METAL STUD COMPRESSION STRUT AT 12'-0" O.C. EACH WAY TO ROOF STRUCTURE. USE (2) #10 SCREWS TOP & BOTTOM SUSPENDED CEILING, LATERAL FORCE BRACING WHERE SUBSTANTIATING DESIGN CALCS. ARE NOT PROVIDED. HORIZONTAL RESTRAINT SHALL BE EFFECTED BY FOUR #12 GA. WIRES SECURED TO THE MAIN RUNNER WITH IN 2" OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90° FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF THE CEILING. THESE HORIZONTAL RESTRAINT POINT SHALL BE PLACED 12' ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 4' FROM EACH WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FROM THE LOAD IMPOSED PER LOCAL CODES. 90°90° 90°90° 2' X 4' OR 2' X 2' T-BAR CEILING MAKE ALL CONNECTIONS TO ROOF STRUCTURE - NO ATTACHMENTS TO UNDERSIDE OF ROOF SHEATING 38" MIN. CLR. CROSS RUNNER OR MAIN RUNNER 4' - 0 " MA X 12 ' - 0 " O. C . 4' - 0" MAX 12' - 0" O.C. NOTE: 1.THE TWO ADJACENT WALLS TO CEILINGS CROSS &/OR MAIN RUNNERS. 2.SUSPENDED CEILING SHALL COMPLY WITH ALL LOCAL CODES. #12 GAUGE WIRE MIN. ACOUSTICAL CEILING TILES 2' X 2' OR 2' X 4' (4 .S.F. MAX.)FINISH FLOOR 45° 6' - 0 " MA X CL G . H G T . NOTE: PROVIDERS #12 GA. WIRES AT ALL FOUR CORNERS OF LIGHT FIXTURE & CLG. DIFFUSERS TYP. SEE WALL DETAIL #2 6" 4' - 0" O.C. ALTERNATE BRACING TO STRUCTURE ABOVE SEE ADJACENT DETAIL 2 CLIP W/ 22-#8 SCREWS EACH SIDE TO TOP TRACK AND BRACE ACOUSTICAL TILE BASE @ CARPET OR TILE POWER DRIVEN PINS TO BE 0.145 HILTI "DN" DRIVE PINS AT 32" O/C - MINIMUM OF 1-1/8" EMBEDMENT WITH 7 8" DIAMETER X 14 GAUGE DISC WASHERS EXISTING CONC. FLOOR 3 5/8" STEEL STUD WITH ONE LAYER 58" GYP. BOARD EACH SIDE WALL DETAIL WALL BRACING DETAIL T-BAR CEILING DETAILWALL DETAIL1 3 4 2 10 ' - 0 " 2' - 3 " SUSPENDED CEILING HEIGHT MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: DETAIL SHEET ANGELA TSAI MD OWNER: D2 DOOR THRESHOLD DETAIL COUNTER DETAIL EXAM ROOM SINK DETAIL 1 4 3 12" maximum 14" maximum Interior floor level1:2 slope maximum 18" per foot maximum slope ENTRY DOOR 34 " M A X I M U M H E I G H T 36" LONG MINIMUM COUNTER FINISHED FLOOR 30" X 48" CLEAR FLOOR SPACE TOE CLEARANCE FINISHED FLOOR 34 " M A X RI M HE I G H T KNEE CLEARANCE TRUNCATED DOME TRUNCATED DOMES IN A DETECTABLE WARNING SURFACE AT REAR ENTRY DOOR SHALL HAVE A CENTER TO CENTER SPACING OF 1.6 IN MINIMUM AND 2.4 MAXIMUM, AND A BASE-TO-BASE SPACING OF 0.65 IN MINIMUM. DETECTABLE WARNING SURFACES SHALL EXTEND 24 IN MINIMUM IN THE DIRECTION OF TRAVEL AND FULL WITH OF THE CURB RAMP. DETECTABLE WARNING DETAIL 5 ACCESSIBLE PARKING DETAIL 6 PUBLIC PARKING PUBLIC PARKING ADA PARKING PARKING ALLEY ACCESSIBLE PUBLIC PARKING IN THE BACK OF BUILDING WITH ONE (1) EXISITING ADA PARKING SPACE. 27 " M I N I M U M 8" MINEXAM ROOM 7" 4" EXAM ROOM SIGNS 2 BRAILLE EXAM ROOM E 5 8" M I N - 2 " M A X HEIGHT OF RAISED CHARACTERS RAISED CHARACTERS SHALL BE 1 32" MINIMUM ABOVE THEIR BACKGROUND. NO CABINETS PERMITTED BENEATH SINK. PIPES UNDER SINK SHALL BE INSULATED TO PREVENT BURNS MILLION CONSTRUCTION & DEVELOPMENT PROJECT ARCADIA ENT 49 E. HUNTINGTON DRIVE ARCADIA, CA 91006 CONSTRUCTION & 124 LAS TUNAS DR ARCADIA, CA 91007 TEL: 626-574-8882 CELL: 626-822-8200 DEVELOPMENT NOTES SHEET NO: SHEET TITLE: SCALE: DETAIL SHEET ANGELA TSAI MD OWNER: D3 TOE CLEARANCE 1 KNEE CLEARANCE 2 9" 6" MAX 11" MIN 8" MIN 27 " M I N REVISIONS BY REVISIONS BY REVISIONS BY