Loading...
HomeMy WebLinkAbout213 S Fifth Ave #B - 2026 -HOUSE INTERIOR WORK 213 S 5TH AVE, B, ARCADIA, CA 91006 VICINITY MAP PROJECT SUMMARY SHEET INDEX DEFERRED SUBMITTALS A Owner:Linkhome Realty Group Job Address: Tel:(626)829-2666 APN:5773-016-102 213 S 5th Ave, B, Arcadia, CA 91006 Legal Des.: TR=52368 LOT 1 CONDO UNIT 2 Job Description: B Building Summary Existing: Zoning: Construction: Lot Size: 1,975 SF R-3 V-B 0.61 acres C The Project Shall Comply With Any And All Requiremens Governing Code: 2025 CALIFORNIA BUILDING CODE (CBC) Having Jurisdiction Including The Following. Of The Legally Constituted Authorities 2025 CALIFORNIA ELECTRICAL CODE (CEC) 2025 CALIFORNIA MECHANICAL CODE (CMC) 2025 CALIFORNIA PLUMBING CODE (CPC) 2025 T-24 ENERGY STANDARDS ( CA ENERGY CODE ) Number of Story: 2 - Story Fire Sprinkler:Yes 2025 CALIFORNIA RESIDENTIAL CODE (CRC) Occupancy Group: R-3 T-1 ARCHITECTURAL TITLE SHEET PROJECT DATA A-1 SITE PLAN 2025 CALGREEN RESIDENTIAL MANDATORY MEASURES 2025 CALGREEN RESIDENTIAL MANDATORY MEASURES T-2 T-3 A-2 EXISTING FLOOR PLAN CONTACT LIST Designer: Topway Archi Design Construction Inc. Address : 18702 Colima Rd Suite 101, Rowland Heights, CA 91748 Property Owner: Linkhome Realty Group Address: 17901 Von Karman Ave, Ste 450, Irvine, CA 92614 Tel # :(626)829-2666 Email :billqin007@gmail.com TEL : 626-400-0736 EMAIL : topwayarchi@gmail.com N PROJECT LOCATION HOUSE INTERIOR REMODEL ON : ADD A NEW PARTITION WALL IN THE LIVING ROOM TO CREATE A NEW BEDROOM.A-3 PROPOSED FLOOR PLAN FIRE SPRINKLER PLAN SHEET DATE 4/ 1/ 2025 REVISIONS R-1 R-2 R-1 R-1 1ST. SUBMITAL: 2ND. SUBMITAL: 3RD. SUBMITAL: PERMIT# CITY PLANING: CITY BUILDING: TO P W A Y AR C H I DE S I G N / B U I L D CO M M E R C I A L AN D RE S I D E N T I A L CA R O L Y N Z E N G 6 2 6 - 4 0 0 - 0 7 3 6 21 3 S 5 T H A V E U N I T B AR C A D I A , C A . 9 1 7 6 2 05-01-2026 T-1 TI T L E S H E E T 5'-8" LEGEND EXISTING LANDSCAPE CONCRETE (E) ELEC. PANEL W.M (E) WATER METER PL PROPERTY LINE G.M (E) GAS METER SCOPE OF WORK: A/C (E) AIR CONDITIONING SYSTEM W.H.(E) TANK GAS WATER HEATER HOUSE INTERIOR REMODEL ON : ADD A NEW PARTITION WALL IN THE LIVING ROOM TO CREATE A NEW BEDROOM. PROPERTY LINE CORNER POINTS AND ELEVATION DATUM 9' - 1 " 19'-9" 3'-10" (E) 213 B (E) 213 A(E) 213 C(E) 213 D 20 ' - 4 " 28 ' - 9 " (E) 211 (E) 209 (E) 207 S 5 T H A V E RAI L W A Y ELEC. PANEL (E) DRIVEWAY (E ) W A L K W A Y A/C ELEC. METER 1 ELEC. METER 2 (E) ELEC. METER SITE PLAN SCALE 1/8" = 1'-0" N SHEET DATE 4/ 1/ 2025 REVISIONS R-1 R-2 R-1 R-1 1ST. SUBMITAL: 2ND. SUBMITAL: 3RD. SUBMITAL: PERMIT# CITY PLANING: CITY BUILDING: TO P W A Y AR C H I DE S I G N / B U I L D CO M M E R C I A L AN D RE S I D E N T I A L CA R O L Y N Z E N G 6 2 6 - 4 0 0 - 0 7 3 6 21 3 S 5 T H A V E U N I T B AR C A D I A , C A . 9 1 7 6 2 05-01-2026 A-1 SI T E P L A N EXISTING FIRST FLOOR PLAN SCALE 1/4" = 1'-0'' 32"32" 30"30" 24" 8'-10" 8'-10" 11'-8"5'10'-9" 15 ' - 2 " 12 ' - 1 0 " 27 ' 11 ' - 8 " 13'-5" 21'-4" 36" 16 ' - 3 " 6'-6" 9' - 6 " 30" 32" 32" 13'-6" 17 ' - 6 " 19 ' - 3 " 9' - 6 " 3' - 3 " 5' - 8 " 6'-7" 24 ' - 9 " 8'-6" 5' 6' - 3 " 13'-3" 13 ' - 7 " SCALE 1/4" = 1'-0'' (No Change) ATTIC ACCESS 9' - 5 " 30" 32" SHOWERØ30" 36'' 36'' 9'-0'' 42'' 13 ' - 8 " 30" 9'-0'' 9'-0'' 36'' 32" 14'-10'' 19'-0'' 9'-5'' 7' - 9 " 12 ' - 1 " 20'7' 23 ' - 4 " 5' - 2 " 12 ' - 5 " 7'-11" EXISTING SECOND FLOOR PLAN 5'-4"3'-11" 14'-10" 2' - 1 0 " N N ELEC. PANEL (E) STORAGE (E) BATHROOM 1 (E) LIVING ROOM (E) GARAGE (E) BEDROOM 1 (E) BATHROOM 2 (E) BEDROOM 2(E) BEDROOM 3 (E) KITCHEN 4 9' - 1 " (E) WATER HEATER 50 GAL (E) ELECTRIC PANEL 8'-0" CEILING HEIGHT LEGEND WATER CLOSET: ≤1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. (E) HARDWIRED INTERCONNECTED SMOKE AND CO DETECTOR COMBO 35'-3" ELEC. METER 1 ELEC. METER 2 (E) FIRE SPRINKLER (E) ELECTRIC METER A/C SHEET DATE 4/ 1/ 2025 REVISIONS R-1 R-2 R-1 R-1 1ST. SUBMITAL: 2ND. SUBMITAL: 3RD. SUBMITAL: PERMIT# CITY PLANING: CITY BUILDING: TO P W A Y AR C H I DE S I G N / B U I L D CO M M E R C I A L AN D RE S I D E N T I A L CA R O L Y N Z E N G 6 2 6 - 4 0 0 - 0 7 3 6 21 3 S 5 T H A V E U N I T B AR C A D I A , C A . 9 1 7 6 2 05-01-2026 A-2 EX I S T I N G FL O O R P L A N PROPOSED FIRST FLOOR PLAN SCALE 1/4" = 1'-0'' 30" 32" SHOWER Ø30" 36'' 36'' 9'-0'' 42'' 13 ' - 8 " 30" 9'-0'' 9'-0'' 36'' 32" 14'-10'' 19'-0'' 9'-5'' 7' - 9 " 12 ' - 1 " 20'7' 23 ' - 4 " 5' - 2 " 12 ' - 5 " 7'-11" 5'-4"3'-11" 14'-10" 2' - 1 0 " N 32" 9' - 8 " 2'-5" 1' 7'-10"12'-2" 9'-9" 4 (E) WATER HEATER, 50GAL (E) ELECTRIC PANEL 8'-0" CEILING HEIGHT LEGEND WATER CLOSET: ≤1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA OF THE U.S. EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. HARDWIRED INTERCONNECTED SMOKE AND CO DETECTOR COMBO KEYNOTE CHANGE THE EXISTING LIVING ROOM INTO A BEDROOM. OUTLET (E) BATHROOM 1 (N) BEDROOM 4 (E) GARAGE (E) KITCHEN 9' - 1 " 12'-2"22'-8" NEW INTERIOR WALL TO BE CONSTRUCT, 2 X 4 STUDS @ 16 O.C. S (N) DIMMER SWITCH S (N) 6" LED Recessed Fixture (N) (N) NON BEARING WALL ON SLAB ON GRADE NON-BEARING WALL TOP CONNECTION ELEC. PANEL ELEC. METER 1 ELEC. METER 2 (E) ELECTRIC METER (E) FIRE SPRINKLER (N) 3' D D SHEET DATE 4/ 1/ 2025 REVISIONS R-1 R-2 R-1 R-1 1ST. SUBMITAL: 2ND. SUBMITAL: 3RD. SUBMITAL: PERMIT# CITY PLANING: CITY BUILDING: TO P W A Y AR C H I DE S I G N / B U I L D CO M M E R C I A L AN D RE S I D E N T I A L CA R O L Y N Z E N G 6 2 6 - 4 0 0 - 0 7 3 6 21 3 S 5 T H A V E U N I T B AR C A D I A , C A . 9 1 7 6 2 05-01-2026 A-3 PR O P O S E D FL O O R P L A N