HomeMy WebLinkAbout213 S Fifth Ave #B - 2026 -HOUSE INTERIOR WORK
213 S 5TH AVE, B, ARCADIA, CA 91006
VICINITY MAP PROJECT SUMMARY SHEET INDEX DEFERRED SUBMITTALS
A
Owner:Linkhome Realty Group
Job Address:
Tel:(626)829-2666
APN:5773-016-102
213 S 5th Ave, B, Arcadia, CA 91006
Legal Des.: TR=52368 LOT 1 CONDO UNIT 2
Job Description:
B
Building Summary
Existing:
Zoning:
Construction:
Lot Size:
1,975 SF
R-3
V-B
0.61 acres
C
The Project Shall Comply With Any And All Requiremens
Governing Code:
2025 CALIFORNIA BUILDING CODE (CBC)
Having Jurisdiction Including The Following.
Of The Legally Constituted Authorities
2025 CALIFORNIA ELECTRICAL CODE (CEC)
2025 CALIFORNIA MECHANICAL CODE (CMC)
2025 CALIFORNIA PLUMBING CODE (CPC)
2025 T-24 ENERGY STANDARDS ( CA ENERGY CODE )
Number of Story: 2 - Story
Fire Sprinkler:Yes
2025 CALIFORNIA RESIDENTIAL CODE (CRC)
Occupancy Group: R-3
T-1
ARCHITECTURAL
TITLE SHEET PROJECT DATA
A-1 SITE PLAN
2025 CALGREEN RESIDENTIAL MANDATORY MEASURES
2025 CALGREEN RESIDENTIAL MANDATORY MEASURES
T-2
T-3
A-2 EXISTING FLOOR PLAN
CONTACT LIST
Designer: Topway Archi Design Construction Inc.
Address : 18702 Colima Rd Suite 101, Rowland Heights, CA 91748
Property Owner: Linkhome Realty Group
Address: 17901 Von Karman Ave, Ste 450, Irvine, CA 92614
Tel # :(626)829-2666
Email :billqin007@gmail.com
TEL : 626-400-0736
EMAIL : topwayarchi@gmail.com
N
PROJECT LOCATION
HOUSE INTERIOR REMODEL ON :
ADD A NEW PARTITION WALL IN THE LIVING
ROOM TO CREATE A NEW BEDROOM.A-3 PROPOSED FLOOR PLAN
FIRE SPRINKLER PLAN
SHEET
DATE
4/ 1/ 2025
REVISIONS
R-1
R-2
R-1
R-1
1ST. SUBMITAL:
2ND. SUBMITAL:
3RD. SUBMITAL:
PERMIT#
CITY PLANING:
CITY BUILDING:
TO
P
W
A
Y
AR
C
H
I
DE
S
I
G
N
/
B
U
I
L
D
CO
M
M
E
R
C
I
A
L
AN
D
RE
S
I
D
E
N
T
I
A
L
CA
R
O
L
Y
N
Z
E
N
G
6
2
6
-
4
0
0
-
0
7
3
6
21
3
S
5
T
H
A
V
E
U
N
I
T
B
AR
C
A
D
I
A
,
C
A
.
9
1
7
6
2
05-01-2026
T-1
TI
T
L
E
S
H
E
E
T
5'-8"
LEGEND
EXISTING
LANDSCAPE
CONCRETE
(E) ELEC. PANEL
W.M (E) WATER METER
PL PROPERTY LINE
G.M (E) GAS METER
SCOPE OF WORK:
A/C (E) AIR CONDITIONING SYSTEM
W.H.(E) TANK GAS WATER HEATER
HOUSE INTERIOR REMODEL ON :
ADD A NEW PARTITION WALL IN THE LIVING ROOM TO CREATE A NEW BEDROOM.
PROPERTY LINE CORNER
POINTS AND ELEVATION
DATUM
9'
-
1
"
19'-9"
3'-10"
(E) 213 B (E) 213 A(E) 213 C(E) 213 D
20
'
-
4
"
28
'
-
9
"
(E) 211
(E) 209
(E) 207
S
5
T
H
A
V
E
RAI
L
W
A
Y
ELEC. PANEL
(E) DRIVEWAY
(E
)
W
A
L
K
W
A
Y
A/C
ELEC. METER 1
ELEC. METER 2
(E) ELEC. METER
SITE PLAN
SCALE 1/8" = 1'-0"
N
SHEET
DATE
4/ 1/ 2025
REVISIONS
R-1
R-2
R-1
R-1
1ST. SUBMITAL:
2ND. SUBMITAL:
3RD. SUBMITAL:
PERMIT#
CITY PLANING:
CITY BUILDING:
TO
P
W
A
Y
AR
C
H
I
DE
S
I
G
N
/
B
U
I
L
D
CO
M
M
E
R
C
I
A
L
AN
D
RE
S
I
D
E
N
T
I
A
L
CA
R
O
L
Y
N
Z
E
N
G
6
2
6
-
4
0
0
-
0
7
3
6
21
3
S
5
T
H
A
V
E
U
N
I
T
B
AR
C
A
D
I
A
,
C
A
.
9
1
7
6
2
05-01-2026
A-1
SI
T
E
P
L
A
N
EXISTING FIRST FLOOR PLAN
SCALE 1/4" = 1'-0''
32"32"
30"30"
24"
8'-10"
8'-10"
11'-8"5'10'-9"
15
'
-
2
"
12
'
-
1
0
"
27
'
11
'
-
8
"
13'-5"
21'-4"
36"
16
'
-
3
"
6'-6"
9'
-
6
"
30"
32"
32"
13'-6"
17
'
-
6
"
19
'
-
3
"
9'
-
6
"
3'
-
3
"
5'
-
8
"
6'-7"
24
'
-
9
"
8'-6"
5'
6'
-
3
"
13'-3"
13
'
-
7
"
SCALE 1/4" = 1'-0''
(No Change)
ATTIC
ACCESS
9'
-
5
"
30"
32"
SHOWERØ30"
36''
36''
9'-0''
42''
13
'
-
8
"
30"
9'-0''
9'-0''
36''
32"
14'-10''
19'-0'' 9'-5''
7'
-
9
"
12
'
-
1
"
20'7'
23
'
-
4
"
5'
-
2
"
12
'
-
5
"
7'-11"
EXISTING SECOND FLOOR PLAN
5'-4"3'-11"
14'-10"
2'
-
1
0
"
N N
ELEC. PANEL
(E) STORAGE
(E) BATHROOM 1
(E) LIVING ROOM
(E) GARAGE
(E) BEDROOM 1
(E) BATHROOM 2
(E) BEDROOM 2(E) BEDROOM 3
(E) KITCHEN
4
9'
-
1
"
(E) WATER HEATER 50 GAL
(E) ELECTRIC PANEL
8'-0" CEILING HEIGHT
LEGEND
WATER CLOSET: ≤1.28 GALLONS PER FLUSH.
TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE
PERFORMANCE CRITERIA OF THE U.S. EPA WATER SENSE
SPECIFICATION FOR TANK-TYPE TOILETS.
(E) HARDWIRED INTERCONNECTED SMOKE AND CO DETECTOR COMBO
35'-3"
ELEC. METER 1
ELEC. METER 2
(E) FIRE SPRINKLER
(E) ELECTRIC METER
A/C
SHEET
DATE
4/ 1/ 2025
REVISIONS
R-1
R-2
R-1
R-1
1ST. SUBMITAL:
2ND. SUBMITAL:
3RD. SUBMITAL:
PERMIT#
CITY PLANING:
CITY BUILDING:
TO
P
W
A
Y
AR
C
H
I
DE
S
I
G
N
/
B
U
I
L
D
CO
M
M
E
R
C
I
A
L
AN
D
RE
S
I
D
E
N
T
I
A
L
CA
R
O
L
Y
N
Z
E
N
G
6
2
6
-
4
0
0
-
0
7
3
6
21
3
S
5
T
H
A
V
E
U
N
I
T
B
AR
C
A
D
I
A
,
C
A
.
9
1
7
6
2
05-01-2026
A-2
EX
I
S
T
I
N
G
FL
O
O
R
P
L
A
N
PROPOSED FIRST FLOOR PLAN
SCALE 1/4" = 1'-0''
30"
32"
SHOWER
Ø30"
36''
36''
9'-0''
42''
13
'
-
8
"
30"
9'-0''
9'-0''
36''
32"
14'-10''
19'-0'' 9'-5''
7'
-
9
"
12
'
-
1
"
20'7'
23
'
-
4
"
5'
-
2
"
12
'
-
5
"
7'-11"
5'-4"3'-11"
14'-10"
2'
-
1
0
"
N
32"
9'
-
8
"
2'-5"
1'
7'-10"12'-2"
9'-9"
4
(E) WATER HEATER, 50GAL
(E) ELECTRIC PANEL
8'-0" CEILING HEIGHT
LEGEND
WATER CLOSET: ≤1.28 GALLONS PER FLUSH.
TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE
PERFORMANCE CRITERIA OF THE U.S. EPA WATER SENSE
SPECIFICATION FOR TANK-TYPE TOILETS.
HARDWIRED INTERCONNECTED SMOKE AND CO DETECTOR COMBO
KEYNOTE
CHANGE THE EXISTING LIVING ROOM INTO A BEDROOM.
OUTLET
(E) BATHROOM 1
(N) BEDROOM 4
(E) GARAGE
(E) KITCHEN
9'
-
1
"
12'-2"22'-8"
NEW INTERIOR WALL TO BE CONSTRUCT, 2 X 4 STUDS @ 16 O.C.
S (N) DIMMER SWITCH
S
(N) 6" LED Recessed Fixture
(N)
(N)
NON BEARING WALL ON SLAB ON GRADE NON-BEARING WALL TOP CONNECTION
ELEC. PANEL
ELEC. METER 1
ELEC. METER 2
(E) ELECTRIC METER
(E) FIRE SPRINKLER
(N)
3'
D
D
SHEET
DATE
4/ 1/ 2025
REVISIONS
R-1
R-2
R-1
R-1
1ST. SUBMITAL:
2ND. SUBMITAL:
3RD. SUBMITAL:
PERMIT#
CITY PLANING:
CITY BUILDING:
TO
P
W
A
Y
AR
C
H
I
DE
S
I
G
N
/
B
U
I
L
D
CO
M
M
E
R
C
I
A
L
AN
D
RE
S
I
D
E
N
T
I
A
L
CA
R
O
L
Y
N
Z
E
N
G
6
2
6
-
4
0
0
-
0
7
3
6
21
3
S
5
T
H
A
V
E
U
N
I
T
B
AR
C
A
D
I
A
,
C
A
.
9
1
7
6
2
05-01-2026
A-3
PR
O
P
O
S
E
D
FL
O
O
R
P
L
A